HomeMy WebLinkAbout03-38P_JAY & LINDA MURTHA ZONING LOCATION SURVEY_MAIN STREETi�
v
c_?
I
I
t
to
t
•r
N
u:
�o
O
K
a�
NIT
N/F
Josephine Koshet��
EXISTING �P Edward W. Kasheta Jr.
--- - - - _ S88 2736 "E S89 28 41 "E
EXISTING IP " 13
7
- - --- -- _ _ — -- - - -- -- I EXISTING F 344. 33'
IL 20' SIDE YARD
10' SIDE YARD
Limit of 100 Year Flood I
Zo 32' Contour
1 /
N/F ? L / EXIS77NG
Horst & Ingrid L. Zo ► cs' a, G / / GARAGE
Mueller
ZONE A-40
/
S88 7'36\ �` -'A a a Exls TING c
603.530$ HOUSE
r?�2
a /
.rf.
EXISTING IPLQ
644.67' .' ``.. ✓ /
'Q N88.2 736 "W — — f _ E XI S Tk1G V
a
ZONE I
,\
Limit of 100 Year Flood �o `` Ce�
32' Contour /� •�.
N/F \ '---------- L �St TOTAL AREA / 5a Andre Charbonneou
N/F - — �, ...4 CA. Yt 457,810 s q. f f.
Allred A. & AnnoDN M. 10.51 acres
Pedmon t, Z `C
V, cp
w
w�
j u' q�lre
\ � ,,, ., .,,,,,.•.r•e ..•,n„N•,r,IM��wrlwrl.+MMIIMIMMMM111M11MININNX'
,�r�rlf A 40 V,LA .._r.r A : A
E>'ISnHt, 1P _�—'_ � ..�.cy.7iss
7.57 acres j 2.94 acres
Rrference Mood. ,
Jr
t j _
1. "As Built Plan Prepared For. Jay be Linda Murtha 1280 Wain Street South
Connecticut Scale 1- 40Date 11-28-00ev Windsor, /
/ --
" ' R5-22-01 By J.R Russo be A�aoclates". ti-f ExISTxIG IP
o J / �
\, x
11 o.
Notes :
1. A portion of the parcel is located in a flood hazard zone, See Panel No. 090038 0008 B. s'a'• ?o v �OGIr-P // N/F
2
/ L� Andre Charbonneou
2. A portion of the parcel is located in Inland wetlands as noted on Reference Map #I.
C� Qy� , �•
3. 100 year' flood elevation is 32' (N.G.V.D. 1929 Datum). \ .)f YAHO
4. Bearings are Based on Reference Map
5. Underground utility, structure and facility locations noted hereon have been compiled,
in part, from record mapping supplled by the respective utility companies or N/F /
governmental agencies, from' parole testimony and from other sources. These location Angela F Vibert
ature. Additionally. \ {
must nally. other such features may
considered as approximate in n
exist on the site, the existence of which are unknown
to J R.Russo do Assn, �lgtea. he ♦ --- IO' SIDE YARD
size, location and existence of all such features must be field determined b. ,i verified
by the appropriate authorities prior to construction. Call Before You Dig 1-800-022-4455 -_ LrlsTt►rc w — --
340.10'
, IP
N8772'23"W -- E� .n-- NIF
N/F Andre Charbonneou
Somueul A. Willard
ZQNIRC QArA BLOCK
HOUSE Zone A- 40 kqqW ,
' 40.000 e0 It Lot area minimum
150 ft Min lot width lWEaML
O 200 It Nn Lot depth
O� tOX MOIL Lot coverage —_
V 15% Mo. Impervious coverage �- — EXISTING STORMSE'= Zoning Location SU.r'Ve
MANHOLE & Q 50 It an front yard APROX. NETT ANDS
2 EXISTIN IP WATER METER + — .r S88 273i - — — 50 It Mn rear yord
20 It Min sde yard • EXISTING IP Prepared For:
-�- so.�.53 z 2.5 Mu■ etDr1.1 ¢ EXISTING u1TtIT Jay & Linda Murtha
30 It Ma. he►ght of building
EXISTMIG HYDH.-
- - Zone I 2
-= 20,000 tW It Lot area minlmum ELECTRICAL :. LSO Main
Street
" N 100 fl Mn lot width • BOLLARD
South Windsor, Connecticut
i-. 150 11 Mn Lot depth _
= a Q
EXISTING IP i ^ — — — — -- -- Q 50% Wax Lot coveroge WATT,..
N88 65% Ma. Impervious coverage —W— — TION OF U G wATCR Le+E
35 It Min Wont yard _ E— .TION OF u.G ELECTRICAL LINE
2S It min rice yard
25 It Min side yard J.R. RUSSO & ASSOCIATES
2.0 Mon st r TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS
phi of building MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON.'` Land Surveyors &Professional Engineers
4o I
lL� HOUSE - CRe iC SCALE
40 0 20 u. 00
th , ( 1N FEET )
U 1 1 inch - 40 fl.
1
This survey and map has been prepared in accordant Sections 20-300b-1 thru 20-300b-20 of the 0� CONIV�,c/rh 1 SHOHAIrI READ
Regulations of Connecticut State Agencies - "Minimu: dards for-Surveysand. Ma in the State of BAST WiNDSt�R� CONNECiiCUT 08088
r`;
Connecticut" as endorsed by the Connecticut A9soclet Land Surveyors, nc. It is an Zoning Locntlon ���; �yC:�N �' EAST
guts based on QeRind nt Resurvex conforming, to H,,- tal Accuracy Class A-2. (8fi0� 823-Q5E39
* - FAX: (880) 623-2485
— - . •�- 1 / 6048
,• l BY SCALE DATE SHEET CHECKED NO.
Trila dorurnent and copies thereof are valid only if they bear the live signature and embossed seal of fQ" _ _
the designated professional. Unauthorized alterations render any declaration hereon nuJJ and void. / -.,L� SUR�,��o�`� �L 1'=40' 8-03-01 1 of 1 ,A4R?000-
/ '►rr.._