Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1000 EVERGREEN WAY
SYMBOLS: (ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS) ELECTRICAL CIRCUITING: ABBREVIATIONS: (ALL ABBREVIATIONS SHOWN MAY NOT APPEAR ON DRAWINGS) ..SUMMIT SMITH R w z m O ry 17-1 ry rn I 0 N wl �I U 0 w (D c� U 0 L U co N t� Cn N r O N ® LIGHTING FIXTURE - CEILING MOUNTED, RECESSED, SURFACE, SUSPENDED 4 LIGHTING FIXTURE - WALL MOUNTED O INDUSTRIAL LIGHT LIGHTING FIXTURE - CEILING SURFACE, SUSPENDED, BOLLARD LIGHTING FIXTURE - WALL SURFACE 0 LIGHTING FIXTURE - CEILING RECESSED 0J LIGHTING FIXTURE - WALL RECESS LIGHT TRACK j OUTDOOR POLE MOUNTED FIXTURE - SEE LIGHTING POLE AND FIXTURE SCHEDULE EMERGENCY BATTERY UNIT CEILING MOUNTED EMERGENCY BATTERY UNIT REMOTE HEAD T)K EXIT LIGHT - CEILING MOUNTED Ti EXIT LIGHT - WALL MOUNTED K �- a SINGLE POLE SWITCH - TOGGLE TYPE LSWITCH DESIGNATION SWITCH TYPE (2) DOUBLE POLE (3) 3 WAY (4) 4 WAY (K) KEY OPERATED (P) WITH PILOT LIGHT INDICATION (T) TIMER SWITCH DLS - INDICATES DUAL LEVEL SWITCHING - SEE DUAL LEVEL SWITCHING DETAIL - SINGLE POLE TOGGLE SWITCH WITH DUPLEX RECEPTACLE COMBINATION +— WALL BOX DIMMER -+-� SURGICAL LIGHT CONTROL —► .o MOMENTARY CONTACT SWITCH X© LOW VOLTAGE SWITCH STATION - SEE LOW VOLTAGE SWITCHING STATION SCHEDULE "X" DENOTES SPECIFIC UNIT RD DIMMING SYSTEM CONTROL STATION - SEE DIMMING SYSTEM SCHEDULE Q TIME CLOCK - SEE TIME CLOCK SCHEDULE © CONTACTOR - SEE CONTACTOR SCHEDULE © PHOTO -CELL A,a © WIRELESS SWITCH - LINE VOLTAGE SOURCE CONTROL SWITCH LEG WIRELESS STATION TYPE - BATTERY SOURCE X/XA OS OCCUPANCY SENSOR - SHOWN WITHIN A SPACE ARE TO CONTROL ALL THE LIGHTING WITHIN THAT SPACE, INCLUDING BUT NOT LIMITED TO GENERAL AMBIENT LIGHTING AND UNDERCABINET TASK LIGHTING SWITCH DESIGNATION DENOTES THE FOLLOWING: (HV) HVAC INTERFACE X DENOTES SPECIFIC TYPE -SEE SPECIFICATIONS X,a pL DAYLIGHT SENSOR SWITCH DESIGNATION "X" DENOTES SPECIFIC TYPE - SEE SPECIFICATIONS XOS SWITCH STATION - SEE SWITCH STATION SCHEDULE "X" DENOTES SPECIFIC UNIT X KEMERGENCY LIGHTING CONTROL UNIT - ECq SEE SPECIFICATIONS AND DETAILS FOR TYPE AND APPLICATION "X" DENOTES SPECIFIC TYPE MLI MINIATURE LIGHTING INVERTER - 1 SEE MINIATURE LIGHTING INVERTER SCHEDULE LCP LIGHTING CONTROL PANEL 1 =-Q DUPLEX RECEPTACLE (DID) DOUBLE DUPLEX (GFI) GROUND FAULT INTERRUPTING (IG) ISOLATED GROUND (SH) SWITCHED TOP HALF (TD) TRIPLE DUPLEX JR) TAMPER RESISTANCE (USB) DUPLEX RECEPTACLE WITH USB CHARGING (WP) WEATHERPROOF W/ GFI RECEPTACLE DUPLEX RECEPTACLE - MOUNTED 6" ABOVE COUNTER BACKSPLASH 46"� DUPLEX RECEPTACLE - MOUNTED AT SPECIAL MOUNTING HEIGHT INDICATED ON DRAWING OR AS INDICATED IN THE ASSOCIATED ARCHITECTURAL ELEVATION. INDICATES MOUNTING HEIGHT WHEN SHOWN. --G SIMPLEX RECEPTACLE 0 PUSH BUTTON SWITCH EQUIPMENT CONNECTION: SPECIAL PURPOSE RECEPTACLE OR MOTOR CONNECTION - SEE EQUIPMENT SCHEDULE DISCONNECT SWITCH ® MOTOR STARTER - SEE EQUIPMENT SCHEDULE G Go GENERATOR 1 T rtm TRANSFORMER 1 ® JUNCTION BOX OMETER SOCKET DISTRIBUTION PANEL - SEE PANEL SCHEDULE 1 INDICATES DESIGNATION A MULTI -OUTLET ASSEMBLY (SEE DETAIL) M A 5 6 #8 NUMBER OF CONDUCTORS IN A RACEWAY INDICATES CONDUCTOR SIZE (WHEN SHOWN) FOR PHASE AND NEUTRAL CONDUCTORS INDICATES NUMBER OF PHASE CONDUCTORS INDICATES NEUTRAL CONDUCTOR INDICATES GREEN GROUND CONDUCTOR (NUMBER INDICATES CONDUCTOR SIZE) INDICATES DETAIL DESIGNATION SEE DETAIL SYMBOL INDICATES SHEET NUMBER KEYED NOTE SYMBOL XX�DENOTES THE FOLLOWING: (GM) GROUND MODULE (PG) POWER GROUND MODULE (RI) REMOTE INDICATOR INDICATES QUANTITY OF DEVICES ASSOCIATED WITH UNIT FB (FB) FLOOR BOX X (PT) POKE-THRU (DA) DUCT ACTIVATION (TP) TELEPOWER POLE (TV) TELEVISION BOX INDICATES TYPE (SEE SPECIFICATION) > TELECOMMUNICATIONS OUTLET MOUNTED 18" AFF, UNLESS NOTED OTHERWISE TELECOMMUNICATIONS OUTLET MOUNTED 6" ABOVE COUNTER BACKSPLASH TELECOMMUNICATIONS OUTLET MOUNTED WITHIN ENCLOSURE INDICATES OUTLET CONFIGURATION. SEE THE TELECOMMUNICATIONS HORIZONTAL CABLING SCHEDULE FOR ADDITIONAL INFORMATION. # INDICATES OUTLET JACK AND CABLE QUANTITY INDICATES OUTLET MOUNTING HEIGHT. (CLG) MOUNTED IN OR ABOVE CEILING (F) MOUNTED IN FLOOR BOX SHOWN ON POWER PLAN (M) MOUNTED IN MULTI -OUTLET ASSEMBLY SHOWN ON POWER PLAN (P) MOUNTED IN POKE-THRU SHOWN ON POWER PLAN (S) SPECIAL MOUNTING HEIGHT EITHER INDICATED ON THE DRAWINGS OR AS INDICATED IN THE ASSOCIATED ARCHITECTURAL ELEVATIONS. (TP) MOUNTED IN TELEPOWER POLE SHOWN ON POWER PLAN (T) MOUNTED IN AV/TELEVISION BOX SHOWN ON POWER PLAN SYSTEM EQUIPMENT CABINET DENOTES THE FOLLOWING: X (DB) DOOR BELL (CA) CABLE TELEVISION (CB) CODE BUTTON (CC) CLOSED CIRCUIT TELEVISION (CLK) CLOCK SYSTEM (DV) DIGITAL TELEVISION (FA) FIRE ALARM (HP) HOUSE PAGING (IC) INTERCOM (IS) INFANT SECURITY (LM) LOCAL MUSIC (LP) LOCAL PAGING (MA) MASTER ANTENNAE TELEVISION (MS) MUSIC SYSTEM (NC) NURSE CALL (P1) PROCEDURE ROOM - TWO WAY COMMUNICATION (P2) PROCEDURE ROOM - MUSIC SYSTEM (PA) PUBLIC ADDRESS (SA) SECURITY ACCESS (SC) SYSTEM CLOCK (TC) TELECOMMUNICATIONS (TV) TELEVISION (RA) RESCUE ASSISTANCE (VD) VOICE DATA (WR) WIRED RADIO DENOTES THE FOLLOWING: (AN) ANNUCIATOR (BB) BACKBOARD (CP) CONTROL PANEL (ER) EQUIPMENT RACK (TC) TERMINAL CABINET (WF) WALL FIELD XX/X FIRE ALARM DENOTES THE FOLLOWING: (C) CEILING MOUNTED (ALL DEVICES SHALL BE WALL MOUNTED UNLESS NOTED OTHERWISE BELOW OR ON PLANS) DENOTES THE FOLLOWING: (CMX) CONTROL MODULE - SEE CONTROL MODULE SCHEDULE (X - DENOTES SPECIFIC UNIT) (CO) CHIME ONLY (COD) CARBON MONOXIDE DETECTOR (CV1) CHIME W/ 15 CANDELA STROBE (CV2) CHIME W/ 30 CANDELA STROBE (CV3) CHIME W/ 75 CANDELA STROBE (CV4) CHIME W/ 110 CANDELA STROBE (DH) DOOR HOLDER (DI) IONIZATION SMOKE DETECTOR (DUCT) (DP) PHOTOELECTRIC SMOKE DETECTOR (DUCT) (HC) HEAT/COMBINATION (RATE OF RISE/FIXED) (CEILING) (HF) HEAT DETECTOR (FIXED) (CEILING) (HO) HORN ONLY (HR) HEAT DETECTOR (RATE OF RISE) (CEILING) (HV1) HORN W/ 15 CANDELA STROBE (HV2) HORN W/ 30 CANDELA STROBE (HV3) HORN W/ 75 CANDELA STROBE (HV4) HORN W/ 110 CANDELA STROBE (MMX) MONITOR MODULE - SEE MONITOR MODULE SCHEDULE (X - DENOTES SPECIFIC UNIT) (PS) PULL STATION (RE) RE-ENTRANT HORN (SI) IONIZATION SMOKE DETECTOR (CEILING) (SO) SPEAKER ONLY (SP) PHOTOELECTRIC SMOKE DETECTOR (CEILING) (SV1) SPEAKER W/ 15 CANDELA STROBE (SV2) SPEAKER W/ 30 CANDELA STROBE (SV3) SPEAKER W/ 75 CANDELA STROBE (SV4) SPEAKER W/ 110 CANDELA STROBE (VO) VISUAL UNIT ONLY (Vol) VISUAL UNIT ONLY, 15 CANDELA STROBE (V02) VISUAL UNIT ONLY, 30 CANDELA STROBE (V03) VISUAL UNIT ONLY, 75 CANDELA STROBE (VO4) VISUAL UNIT ONLY, 110 CANDELA STROBE A BOUNDARY DRAWN AROUND A SYSTEMS SYMBOL INDICATES THE ACTUAL SIZE OF THE DEVICE. THE BOUNDARY WILL BE SHOWN ONLY IF THE DEVICE IS LARGER THAN THE INDUSTRY STANDARD. LIGHTING FIXTURES: INDICATES FIXTURE TYPE (TYPICAL) A ---A A A A 1a,X-3b X-3b,1a 1a,3b X-3* X-3* (X-*) SECOND DESIGNATOR (TYPICAL) EMERGENCY LIGHTING FIRST DESIGNATOR (TYPICAL) CONTROL DESIGNATOR (TYPICAL) SINGLE DESIGNATOR (TYPICAL) LIGHTING CIRCUITING NOTES - 1. FIRST DESIGNATOR INDICATES THE CIRCUIT AND CONTROL MEANS ASSOCIATED WITH THE OUTBOARD LAMPS. 2. SECOND DESIGNATOR INDICATES THE CIRCUIT AND CONTROL MEANS ASSOCIATED WITH THE INBOARD LAMPS. 3. SINGLE DESIGNATOR INDICATES THE CIRCUIT AND MEANS OF CONTROL FOR THE ENTIRE FIXTURE. 4. DESIGNATOR SHOWN WITHIN( ) INDICATES CIRCUITING AND/OR CONTROL VIA AN EMERGENCY LIGHTING CONTROL UNIT. REFER TO LIGHTING DETAILS FOR WIRING DIAGRAM(S). 5. SHADING INDICATES LAMP(S) SERVED FROM EMERGENCY, CRITICAL CARE OR LIFE SAFETY BRANCH (TYPICAL). DESIGNATOR DESCRIPTION: X-3bLOWER CASE LETTERS INDICATE SWITCH DESIGNATION CONTROLLING ASSOCIATED LAMP(S). ABSENCE OF ANY LETTER INDICATES FIXTURE/LAMP(S) CONTROLLED VIA SWITCH(ES) IN THE ASSOCIATED ROOM. UPPERCASE "U" INDICATES ASSOCIATED LAMP(S) ARE UNSWITCHED. INDICATES THE CIRCUIT NUMBER SERVING FIXTURE/LAMP(S). INDICATES BRANCH PANELBOARD SERVING THE DEVICE. SEE PLAN FOR AREAS SERVED BY PANELBOARD(S). ELECTRICAL DEVICES: XX +-- SPECIAL OUTLET �X-3 X-3 DESIGNATOR DESIGNATOR DESIGNATOR DESCRIPTION: X-3 INDICATES THE CIRCUIT NUMBER SERVING DEVICE. INDICATES BRANCH PANELBOARD SERVING THE DEVICE. SEE PLAN FOR AREAS SERVED BY PANELBOARD(S). HEATH CARE -120 VOLTS EM - EMERGENCY BRANCH OS - OPTIONAL STANDBY N - NORMALBRANCH HEATH CARE - 277 & 120 VOLTS NH- NORMAL BRANCH - 277 VOLTS NL - NORMAL BRANCH -120 VOLTS OSH- OPTIONAL STANDBY - 277 VOLTS OSL- OPTIONAL STANDBY - 120 VOLTS NOTE DESCRIPTIONS - OFFICE-120 VOLTS N - NORMAL BRANCH EM- EMERGENCYBRANCH OS- OPTIONAL STANDBY OFFICE - 277 & 120 VOLTS NH - NORMAL BRANCH - 277 VOLTS NL - NORMAL BRANCH - 120 VOLTS EMH- EMERGENCY BRANCH - 277 VOLTS EML- EMERGENCY BRANCH - 120 VOLTS OSH- OPTIONAL STANDBY - 277 VOLTS OSL- OPTIONAL STANDBY - 120 VOLTS GENERAL NOTES - NOTES THAT APPLY TO ALL DRAWINGS WITHIN THE DRAWING SET. SHEET NOTES - NOTES THAT APPLY TO THE SHEET ON WHICH THEY APPEAR. KEYED NOTES - NOTES THAT APPLY TO AN AREA, ITEM AND/OR DEVICE ON A FLOOR PLAN OR DETAIL. DETAIL NOTES - NOTES THAT APPLY TO A SPECIFIC DETAIL. THE LIGHTING DESIGN FOR THIS PROJECT SET IS IN COMPLIANCE WITH IECC 2012. ABV ABOVE AFF ABOVE FINISHED FLOOR AFG ABOVE FINAL GRADE ALT ALTERNATE ALT SW ALTERNATE SWITCH ARCH AMuri TECT BFC BELOW FINISHED CEILING BFG BELOW FINISHED GRADE BLDG BUILDING BOL BUILT IN OVERLOAD BPC BOLTED PRESSURE CONTACT SWITCH BRKR BREAKER CB CIRCUIT BREAKER CKT CIRCUIT CLG CEILING CID CONTROLPANEL CS COMBINATION STARTER DE DUAL ELEMENT FUSES DIR DIRECT DISC DISCONNECT DN DOWN EC ELECTRICAL CONTRACTOR ELEV ELEVATION EMER EMERGENCY EMT ELECTRIC METALLIC TUBING EOL END OF LINE RESISTOR EP EXPLOSION PROOF ER EXISTING REMOVE FROM SERVICE ERL EXISTING RELOCATED ES EXPOSED STRUCTURE ETR EXISTING TO REMAIN EX EXISTING EWC ELECTRIC WATER COOLER F FLUSH FBO FURNISHED BY OTHERS FDR FEEDER FIXT FIXTURE FLUOR FLUORESCENT FLR FLOOR FS FLOW SWITCH FVNR FULL VOLTAGE NON -REVERSING GC GENERAL CONTRACTOR GFI GROUND FAULT INTERRUPTED GRC GALVANIZED RIGID CONDUIT GIRD GROUND GRDG GROUNDING GYP GYPSUM BOARD HOA HAND -OFF -AUTO SWITCH HVAC HEATING, VENTILATING, & AIR CONDITIONING HW HEAVYWALL IL INTERLOCK IMC INTERMEDIATE METALLIC CONDUIT JB JUNCTION BOX kVA KILO VOLTAMPERE LG LAY -IN GRID LTG LIGHTING LV LOW VOLTAGE LVT LINE VOLTAGE THERMOSTAT MAG MAGNETIC STARTER MAN MANUAL STARTER MC MECHANICAL CONTRACTOR MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MSB MAIN SWITCHBOARD MTD MOUNTED NIC NOT IN CONTRACT NU NEAR UNIT OU ON UNIT P POLE PB PUSH BUTTON PEND PENDANT PC PLUMBING CONTRACTOR PE SW PNEUMATIC SWITCH PLBG PLUMBING PNL PANEL PVC POLYVINYL CHLORIDE R RELAY RAI REMAIN AS IS RE/CKT RECONNECT TO EXISTING CIRCUIT RECEPT RECEPTACLE RM ROOM RVS REDUCED VOLTAGE STARTING S SPLINE SEL SW SELECTOR SWITCH SP SW SPEED SWITCH SURF SURFACE SW SWITCH TC TIME CLOCK TCC TEMPERATURE CONTROL CONTRACTOR TCP TEMPERATURE CONTROL PANEL TYP TYPICAL UG UNDERGROUND UNIV UNIVERSAL USS UNIT SUBSTATION WP WEATHERPROOF XFMR TRANSFORMER ELECTRICAL SHEET INDEX No. TITLE F=nn l RYMRg R ARRRE\/IAT[nNS & .qHEET INDEX E010 SITE PLAN - ELECTRICAL E101 OVERALL FIRST FLOOR PLAN - ELECTRICAL E102 OVERALL :SECOND FLOOR PLAN - ELECTRICAL E200L LOWER LEVEL AND FIRST FLOOR PLAN - AREA A - LIGHTING E200P LOWER LEVEL AND FIRST FLOOR PLAN - AREA A - POWER E200T LOWER LEVEL AND FIRST FLOOR PLAN - AREA A - TECHNOLOGY E201 L FIRST FLOOR PLAN - AREA B - LIGHTING E201 P FIRST FLOOR PLAN - AREA B - POWER E201T FIRST FLOOR PLAN - AREA B - TECHNOLOGY E202L FIRST FLOOR PLAN - AREA C - LIGHTING E202P FIRST FLOOR PLAN -AREA C - POWER E202T FIRST FLOOR PLAN - AREA C - TECHNOLOGY E203L SECOND FLOOR PLAN - AREA A - LIGHTING E203P SECOND FLOOR PLAN - AREA A - POWER E203T SECOND FLOOR PLAN - AREA A - TECHNOLOGY E204L SECOND FLOOR PLAN - AREA B - LIGHTING E204P SECOND FLOOR PLAN - AREA B - POWER E204T SECOND FLOOR PLAN - AREA B - TECHNOLOGY E205L SECOND FLOOR PLAN - AREA C - LIGHTING E205P SECOND FLOOR PLAN - AREA C - POWER E205T SECOND FLOOR PLAN - AREA C - TECHNOLOGY E206 ROOF PLAN - ELECTRICAL E300 ENLARGED PLANS - UNIT PLANS E301 ENLARGED PLANS - UNIT PLANS E302 ENLARGED PLANS - UNIT PLANS E303 ENLARGED PLANS - ELEC & IT ROOMS E304 ENLARGED PLANS - KITCHEN AND EXPO. KITCHEN - POWER E305 ENLARGED PLANS - LOUNGE & BISTRO - POWER E306 ENLARGED PLANS - COUNTRY KITCHENS - POWER E400 ONE LINE DIAGRAM - SYMBOLS E401 ONE LINE DIAGRAM E402 ONE LINE DIAGRAM E500 LIGHTING DETAIL E501 LIGHTING DETAILS E510 POWER DETAILS E520 TECHNOLOGY DETAIL E600 LIGHTING ;SCHEDULES E601 LIGHTING SCHEDULES E602 LIGHTING SCHEDULES E603 LIGHTING SCHEDULES E610 POWER SCHEDULES E611 POWER SCHEDULES E612 POWER SCHEDULES E613 POWER SCHEDULES E620 TECHNOLOGY SCHEDULES DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & !� DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 \�\\ \F CONNECT '�opHER No. 0133339 ry 10 This cortiftfsd itpt,. t;,dj. p; r 0nq..9p�;Sifl�e tk�ste u,� gin. ct+Jfes ,of. i ns°to bo ®rec -t�fat tat�titLL rwltt ftrr.;.. -.f �,;t e S r n t r?3ri I �n�,?ton., Pf?IHJtnf3.:��Bi1::�i�tttt:rJ6';4iY"c 4— :§4��?!i• t' sSsnt.ili 9/ l diCsa+ic JS6Y¢ftpCi*} ; f�'ti h3 au"bA Ji,l"la3g,.:f5aacy1 ,•6f�err�rAe�tr31�t�.q7u3Ad�se"bt°tea "'" iiL��syn1 s?FemtlYf, ixliM p4htw tq �ciy 3h?sftirt 3 V'b * ftvt _A iamI tatmr�;tt.�3i 'x4t31, tmrlt Ivitmw Ele*(CO ' S 1006 FU"Cez-) W C'rko %51 S_ CZ O O CDs= CD O S._ rn > W O ® a C CCS aD -� N U � O W U —0 C-0 w Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SYMBOLS, ABBREVIATIONS & SHEET INDEX ai U N C_ C_ Sheet Number: U Cn a CU EOOO !Y N c d SHEET NOTES - 1. "R", AS IN R-*, INDCATES A RELAY CONTROLLED CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/1AL. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR MORE INFORMATION. COORDINATE ALL FINAL LOCATIONS OF SITE LITHING FIXTURES WITH CIVIL SITE LIGHTING PLANS. '.SUMMIT SMITH DEVELOPMENT 941 N Rmprlwav ®LCP R1-38 LCP R1-37 LCP R1-38 ® LCP R1-37 LCP R1-37 0 I n ®LCP R1-38 LCP ® R1-38 ®LCP R1-37 ® LCP R1-37 ®LCP R1-37 ®LCP R1-37 LCP ® R1-37 0 F-- —I IT 0019 LCP LCP R1-38 ® ® R1-38 LCP LCP LCP R1-38 R1-38 R1-38 ® LCP R1_3R ® LCP R1-37 LCP ® R1-37 ®LCP R1-37 ®LCP R 1 _3R ® LCP R 1 _38 LCP ® R1-38 ®LCP R1-37 ®LCP R1-37 ®LCP R1-38 ® LCP R1-38 m LCP `d R1-37 ® LCP R1-38 m LCP R1-37 2. UTILITY TO PROVIDE SEPERATE SECONDARY SERVICE TRANSFORMERS FOR 480V AND 208V SERVICES. EACH TRANSFORMER SHALL HAVE SEPERATE METERING AND CT CABINET TERMINATIONS. COORDINATE THE INSTALLATION OF THE PRIMARY CABLE PROVISIONS FROM THE UTILITY VAULT TO THE SECONDARY SERVICE TRANSFORMERS. ALL CONDUIT AND CABLE SHALL BE PROVIDED FROM EACH UT ILI I i TRANSFORMER TO THE TERMINATIONS POINTS WITHIN THE BUILDLING. KEYED NOTES - a 1. GENERATOR SET LOCATION. CONCRETE PAD PROVIDED BY OTHERS. 2. G.C. SHALL PROVIDE CONCRETE ENCASED DUCT PACKAGE FROM THE GENERATOR LOCATION TO THE BUILDING. PROVIDE AND INSTALL (2) 4" CONDUITS AND (2) 2" PVC CONDUITS FOR GENERATOR POWER AND SIGNAL. CONDUITS SHALL ROUTED BETWEEN GENERATOR AND BUILDING FOUNDATION. SEE DETAIL E510 FOR TYPICAL DUCTBANK DETAIL. 3. GENERATOR POWER AND SIGNAL CONDUITS SHALL BE ROUTED BELOW FLOOR AND STUB -UP AT EMERGENCY POWER DISCONNECTS WITHIN THE EMERGENCY POWER DISTIBUTION ROOM. UTILIZE SCHEDULE 40 PVC CONDUIT FOR HORIZONTAL PORTIONS OF ROUTE, AND RIGID STEEL ELBOW AND STUB UP WHERE RUNS ENTER ELECTRICAL ROOM. 4. REMOTE GENERATOR SHUT OFF DEVICE. 5. REFERENCE 'TS SERIES' LOW VOLTAGE DRAWINGS FOR ADDITIONAL INFORMATION FOR INCOMING SERVICE PROVIDER REQUIREMENTS TO THE TELECOM DMARC. 6. (2) 4 INCH SCHEDULE 40 PVC CONDUIT FOR ELECTRICAL SERVICE. TERMINATE AS DIRECTED BY CONNETICUT POWER & LIGHTS. 7. PROVIDE CONCRETE ENCASED DUCTBANK PACKAGE FOR INSTALLATION OF (2) SCHEDULE 40 PVC ELECTRICAL CONDUITS ROUTING BENEATH ROADWAY. REFERENCE TYPICAL DETAIL ON SHEET E510 FOR ADDITIONAL INFORMATTON. COORDINATE INSTALLATION REQUIREMENTS WITH CONNETICUT POWER & LIGHTS PRIOR TO INSTALLATION. 8. UTILITY PROVIDED TRANSFORMER. PROVIDE (2) 4 INCH CONDUITS FROM PAD MOUNTED TRANSFORMER TO BUILDING. CONDUITS SHALL BE ROUTED ABOVE GROUND STUBBED INTO THE ELECTRICAL ROOM. REFERENCE E401 FOR ADDITIONAL INFORMAITON. 9. TRANSER SWITH START CONTACT SIGNAL WIRING TERMINAL BOX. Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD R//d �TLF� I M CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 �II Vl�.l OO( ��- DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 I r-d@ringdu.cor RD Project Number: 218092.00 \\�11111111 J� �F cONNec,HER T�''. cot" No. 0033339 �O \\ 7 t � Z-r-iaf, O O � U W N 1.. 0 N � n l J `W W 0 q1— ® U � L CD O^ LU U L � .- TCo � i Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SITE PLAN - ELECTRICAL N M M N rn 0 N N TRUE PLAN NORTH NORTH SITE PLAN -ELECTRICAL 1" = 20'-0" C_ U Q Sheet Number: E01 0 .N a cB 0- NH/1-1 (480Y/277V NORMAL) NL/1-1 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) NH/1-1 (480Y/277V NORMAL) NL11-2 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) SHEET NOTES - A. REFERENCE SHEET E000 FOR SYMBOLS, ABBREVIATIONS, GENERAL NOTES & INDEX. �-�SUMMIT SMITH DEVELOPMENT WALK-IN COOLER NH/1-1 (480Y/277V NORMAL) 1035A o NL/1-1 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) NH/1-1 (480Y/277V NORMAL) NL/1-K (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) I KITCHEN 1035 DISHWASI NH/1-1 (480Y/277V NORMAL) 1037 NI /1-(1RY/1r\/ Nl)PR/AIK2V2Er) EM/1-2 (208Y/120EMRGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) I NH/1-1 (480Y/277V NORMAL) NL/1-6 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) IA/A, �TATIOI. loll NH/1-1 (480Y/277V NORMAL) NL11-6 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) NH/1-1 (480Y/277V NORMAL) NL/1-5 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) F� LL1 Z m O ry 0 ry rnI 0 N LI �I U LL1 c- 0 U n M N 0 N N � A D13 ? VIAITF,` Ir ELE E2 BISTRO 1017 C3 1014 PANTRY 1018 CONCIERGE 1016 STAIR COPY S4 1015 CORR C1002 LAUNDRY 1011 C3 1010 BUSINESS OFFICE 1009 025 CLASSROi-- I 1026 ,TOR 1027 I TOR 1024 CLASSROOM 1023 ELEC 1022 I GRAND LOBBY 1001 CONFERENCE Pn ! 1008 EXEC DIR VET SPITALT' 1007 1 nru; NH/1-1 (480Y/277V NORMAL) NL/1-2 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) - NH/1-2 (480Y/277V NORMAL) NL/1-3 (208Y/120V NORMAL) EM/1-1 (208Y/120V EMERGENCY) OS/1-1 (208Y/120V OPTIONAL STANDBY) I I I NH/1-2 (480Y/277V NORMAL) NL/1-3 (208Y/120V NORMAL) EM/1-1 (208Y/120V EMERGENCY) NH/1-2 (480Y/277V NORMAL) OS/1-1 (208Y/120V OPTIONAL STANDBY) NL/1-3 (208Y/120V NORMAL) NH/1-2 (480Y/277V NORMAL) EM/1-1 (208Y/120V EMERGENCY) NL/1-4 (208Y/120V NORMAL) OS/1-1 (208Y/120V OPTIONAL STANDBY) EM/1-1 (208Y/120V EMERGENCY) OS/1-1 (208Y/120V OPTIONAL STANDBY) NH/1-2 (480Y/277V NORMAL) NL/1-4 (208Y/120V NORMAL) EM/1-1 (208Y/120V EMERGENCY) OS/1-1 (208Y/120V OPTIONAL STANDBY) I I IVIi"tC i II'VU 10 0 NH/1-1 (480Y/277V NORMAL) NH/1-2 (480Y/277V NORMAL) NL/1-5 (208Y/120V NORMAL) NL/1-4 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) EM/1-1 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) OS/1-1 (208Y/120V OPTIONAL STANDBY) TRUE PLAN NORTH NORTH OVERALL FIRST FLOOR PLAN - ELECTRICAL 3/32" =1'-0" B. INFORMATION SHOWN INDICATES PANELBOARD AND CIRCUITING BOUNDARIES. E.C. SHALL CIRCUIT ALL DEVICES AND EQUIPMENT FROM THE PANELBOARD AND ELECTRICAL ROOMS AS INDICATED. REFERENCE E303 FOR ELECTRICAL ROOM LAYOUTS. 2d,1 N. Rr�adway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 DIN HATER uc u 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.col RD Project Number: 218092.00 c 0 N NFCT ° No. 0033339 _-140.0 � o o C- U O O �I— C1) O V J � O N U O N W � U � o TTCIO a 1 ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: OVERALL FIRST FLOOR PLAN - �ELECTRICAL J J U a� U Q Sheet Number: 0 U CIO E101 CIO Y C 0- 0 '.SUMMIT SMITH DEVELOPMENT ti F��2?7 (48o 7 p� �OQ��� 0 o��- c < s � Os2/?2�?08 y�i2 >I ATi �OY sPP�,�72o VNOOh,M �ST� �o a ,oT Rc J 1 /16 2 � NH/2-1 (480Y/277V NORMAL) NU2-6 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) -- NH/2-1(480Y/277V NORMAL) NL/2-5 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) R w z m O rK 0 rn I 0 N w I �I U W 0 CU U 0 -0 L 2 I N M 0 co N C a� E U 0 0 W 0 0 0 X C n N lC M M N_ M r 0 N NH/2-1 (480Y/277V NORMAL) NL/2-6 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) NH/2-2(480Y/277V NORMAL) NU2-3 (208Y/120V NORMAL) EM/2-1 (208Y/120V EMERGENCY) OS/2-1 (208Y/120V OPTIONAL STANDBY) I I I NH/2-1(480Y/277V NORMAL) I NH/2-2(480Y/277V NORMAL) NL/2-5 (208Y/120V NORMAL) NU2-4 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) EM/2-1 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) I OS/2-1 (208Y/120V OPTIONAL STANDBY) NH/2-2(480Y/277V NORMAL) NL/2-3 (208Y/120V NORMAL) EM/2-1 (208Y/120V EMERGENCY) OS/2-1 (208Y/120V OPTIONAL STANDBY) -� NH/2-2(480Y/277V NORMAL) NU2-4 (208Y/120V NORMAL) EM/2-1 (208Y/120V EMERGENCY) OS/2-1 (208Y/120V OPTIONAL STANDBY) TRUE PLAN NORTH NORTH OVERALL SECOND FLOOR PLAN - ELECTRICAL 3132" =14" SHEET NOTES - A. REFERENCE SHEET E000 FOR SYMBOLS, ABBREVIATIONS, GE .IEI? " lNIOTES Q. I,.�DEX. B. INFORMATION SHOWN INDICATES PANELBOARD AND CIRCUITING BOUNDARIES. E.C. SHALL CIRCUIT ALL DEVICES AND EQUIPMENT FROM THE PANELBOARD AND ELECTRICAL ROOMS AS INDICATED. REFERENCE E303 FOR ELECTRICAL ROOM LAYOUTS. KEYED NOTES - a 1. * 2d,1 ti Rrr)n(q%A1ay Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 2 1 C 13 A I M[M7LI—d CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & L L UUUMA I tAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778,1700 / Fax: 414.778,2360 / r-d@ringdu.cor RD Project Number: 218092.00 �' of G0NNFpr�'�, '• .� �� Na. 0033339 O co U O L V) W O 4-- CIO O a N L- 0 � O O -1 W u co o CIO r� Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: OVERALL SECOND FLOOR PLAN - 0-ELECTRICAL J J N 15 U N U Q Sheet Number: U Cn T CUEl 02 c O U n 00 0 N OD (EM-12C!l I I 1 NL6 NL-101 I 9 E302 I I I I II "----- W5 --- RL-4 O O DA P20 DA EM-12U RL-3 RL-3 AA NH-1 OS g AA NH-15 KEYED NOTES - a — 1. LIGHTING AND CONTROLS PER EQUIPMENT, NOT SHOWN. — — — — — — _ OA _ _ J — _ 2. FIXTURE SHALL BE CONNECTED TO UL924 EMERGENCY OA° R°-8 OA° I — _ _ _ — — _ OD LIGHTING CONTROL DEVICE, SO THAT FIXTURE ONLY I 4 I RL-1 RL-1 I � I � I — _ J T — � _ — RL-8 COMES ON WHEN NORMAL POWER IS LOST. NL6 NL-7 E301 1 I E301 I E301 XF 3. DIMMERS SHALL BE BANKED IN GROUPS OF THREE AND TACKED VERTICALLY. DIMMERS "X","Y", AND "Z" CONTROL EM-13U _ THE LIGHTS MOUNTED IN THE 2-STORY CEILING. REFER TO EM-121� I I NL6 NL-15 I NL6 NL-25 1 I � 1 FH — — — SHEET E204L FOR MORE INFORMATION. I DA DAO E301 E301 I EM-12UM-12U 1 I EM-12U RL-2 11I.011 I XF I NL6 N L-33 I NL6 N L-45 1 1 I EM-13U X DA Lot I I I E300 I I I 1 O EM-12U O I 1 I I I RL RL-3 P20 R L-3 1 I I I ODA DA O I 1 I I FH v� EM-12U L- L_----------L-------- I IIEM-12U FH EM-12U I W5 — TOT EM-13U � W5 W5� XF I I I I NL6 NL-53 1 DA DA RL54q P20 DA RL-4 RL-4 EM-13U �' — — — — o — _ — — — — DA L XF 0RL-3 ORL-3 ORL-3 ODA RL-P20 OEM-12U ODA ODA ODA ODA — — — — — J EM-12UO�OEM J13U RL-3 RL-3 RL-3 EM-12U RL-3 P20 W5 W5 :ff( XG L.02 I------------- FC )KXG XF RL-3 DA DA RL-4 DgRL-4 DA DA EM-13U W5� DA DA NH-15 OS EM-13U EM-13U 0RL-3 OEM-12U P20 0RL-3 ORL-3 EM-12UO TAT P20 RL-4 0RL-3 OEM-12U � D OS B oT W5 RL-3 W5 W5 RL- W5 1 O OCN ---�RL-4 --- ----- �RL-4 _-9RL-4 -- RL-4: -�- �JB DA RA 3 1:1NH AA DA OS B WE I— T NL6 NL-63 NH-15 AA CA CFI CN NH-15 4I I I 1 NH-15 F7NH-15 NH-15 JB JB O O CARE EM-12U OS B EM-12 EM-12 DA RL-3 -�- OS B PARTNFP' i OS 0011 I I 1 r NH-15 B i v FC CN CN AA AA - CA NH-15 DA DOA NH-15 NH-15 NH-15 NH-15 9 EM-12U FC I I 1 1 I AA NH-15 RL-3 EM-12U DA I I NL6 NL-81 1 NL6 NL-71 E300 NH-15 CA DA DA RL-3 FH FH NH-15 0RL-3 0RL-3 O EM-12U EM-12U I 1 OS tAA ORL-3 RL-3� XF L� FH XF I 4 NL6 NL-91 1 ,� 1 1 AA ❑ EM-103 3U NH-15 -3 - NH-15 DA XG RL DM-12U0 EM-12U EM-13U EM-12� E301 1 E301 1 E301 1 RU I I OSB RL-3 -BEM-13U---��----- `—-------�— — I — --+ 0 DA OD AA AA RL-3 DA I I RL-8 AA NH-15 NH-15 RL-3 NH-15 OS g O P2o � A RL-3 I NL6 NL-109 1 -- RD30 1 � � B TRUE PLAN NH-15 3 NH-15 NH-15 DA 0 I NORTH NORTH C EM-12U{I 1 I LOWER LEVEL PLAN - LIGHTING W51 E301 U RL-4 I FH I NH-15 L----- —_J OD (_ _ I �A-40 4 I XF 1— NL6 NL-7 E301 EM-14UFH 1 % 1 4 — FH EM-15U E301 E301 1 NL6 NL-25 1 NL6 NL-15 1 I 1 I EM-15U 1 E300 � 1 I I 1 I I I 1 I I I I FH I I 1 FH EM-15U IEM-15U W5---J XF 1 NL6 NL-35 EM-14U 1 I�Ey 1 I ©1.01----------------------JXF RA -15U DAO XF �W5 W5 EM-14U MA-2 20 �W5 EM-14�U Dq A-3 A-3 — ®— A-3 OT j"'S P20 O Rq_2 O ODA P20 O DA ODA ODA P20 O DA i 1W5 DA- W5 RA-2 DA A-2 3�-2 A-2 EM-15U A-2 /�A-2 A-2 XFT� 9RA-3EM 15U 6RA-3 EM-15U DA EM-14U EM-15U O NL6 NL-45 I I ❑CA NH ❑ CA OS B OS B I I -12 CA FC FC ❑ CA ❑ CA O XF EM-15U NH-12 NH-12 NH-12 NH-12 NH-12 EM-14U OS B CA I I CA RA-8 1J SHEET NOTES - 1. REFER TO ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR EXACT LOCATION OF ALL ELECTRICAL DEVICES PRIOR TO COMMENCING INSTALLATION 2. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL POSITION OF THE CIRCUIT BREAKERS IN THE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. 3. REFERENCE SHEET E102 FOR PANELBOARD BOUNDARIES INDICATING PANELBOARDS SERVING THIS SPACE. 4. ALL 480Y/277V, NORMAL BRANCH CIRCUITS 'NH' FEEDING AREA SHOWN SHALL BE FED FROM "NH" PANELS, AS NOTED. 5. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NL' PANELS, AS NOTED. 6. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. 7. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'EM' PANELS, AS NOTED. 8. "RL" AS IN "RL-** INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/LL UNLESS OTHERWISE NOTED. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 9. "RA" AS IN "RA-**" INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/1AL UNLESS OTHERWISE NOTED. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 10. ALL EMERGENCY BATTERY UNIT (EBU) LIGHTS SHALL BE WIRED TO UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA WHERE EBU IS LOCATED. FAA I NH-12 I E301 I E301 1 1 FH OS B I m 1 I F FH I 1 EM-15U M-15U NL6 NL-7 NL6 NL-15 E301 I r I I I E301 1 I 1 NL6 N L-25 1 NL6 N L-35 1 1 1 NH-1 I 1 F 1 E300 f I I I I I I I I i I I I I 69 - O I I FH 1 FC DA I I I FH EM-15U I 1 NH-12 EM-15UL-----_-----_---- I I 1EM-15U I 1 DA W5 W5 XF I 1 E 1.03 XF NL6 NL-4� EM-15U A-5 RA-5 EM-14U`l`0I I � EM-14U1 1 O ODA ODA 0 ODAgP20 ODA `----------------� DA00 XG A-4 RA-4 DA A- A-4 EM-15U P20W5 W5 DA EM-15U W51 X EM-14U EM-15U A-4 DA ):�F`20DA-5DA DA A-5DAM-15U EM-14UPZOATXF W5 O EM-15U RA-4 O A-4 O EM-15U O A-4 0 RA 4 O A-4 O T ORA-4 CN OS B OS B EM-14U W5 _ _ W — RA 5: DA A CN NH-12 AA RA-5 9 RA-5 � A-5 O W E _r A-4 A-4 NH-12 NH-12 DA NH-12�-------_—�------- ---- I NH-12 41 1 1 NL6 NL-53 O O _ 1 I 1 I DA DA B 1 Os I I I EM-15U A-4 F__] CN NH-12 � NH-12 � 69 B NH 12 S - CA --- XF 1.05 CA CA I I ❑ NH-12� XF �EM-14U A-8 NH-12 CA O O CN AA AA 1 I I 1 INL6 NL-55 I I Iy14U ❑ RA-8 1:1RA-8 v EM-15U RA-8 XG �NH-12 DA DA NH-12 NH-12 NH-12 1 I NL6 NL-71 I ,� E300 I I CA 1� EM-14U RA-4 A 4 1 NL6 NL-81 1 1 NL6 N L-63 E300 4 I CA NH-12 El EMERG ^XS O OS B CA FH FH I 4 1 I 1 AA XF DA EM-15U EM-15U o — — — — — — -- — E301 I NH EM-15U P ���r' NH-12 NH-12 EM-14U NH-12 ORA-4 P204 EM--15U� I E301 I 1 E 01- 0DA I - CA it' FCFC IL �NH-121:1 XF)K FH FH I 1 E301 1 1 L — — — — — — — _ OS B RA-8 NH-12 NH-12 NH-12 3 N EM-14U)K EM-14U XG E E NH-12--------�— 1 —_J XS CA ❑ EM-14U� 01.06 4�,PNH-12 NH-12 CA CA NH-12 RA-9 ©1.07 0 F -69 FC EM-14U NH-12 FC OD �{ A ❑ CA � NH-12 RA-40 XF RA-9 CA XS4@ EM-14U EM-15U NH-12 xs �NH-12 XS FD NH-12 FC NH-12 FD NH-12 NH-12 XS Li N H-12 9..P OD A-1 v RA12 LW W6 PRIVA A-12a RA-12 DININ DA DA DA 1032 R0 A-39b RA-39b RA-39b >�P16 RA �P16 RA-12a RA-1 RA-12 A- O O O DA DA DA RA-39b RA-39b RA-39b LW LW A-12a RA-12a 14U AA OS B AA - -&9 XXF 4 EM-14U XF0 AE 3F --------- ---- ----J EM-14U EM-15U T 1 1 AE AE 1 EM-15U NH-12 XF1 O EM-14U DA E301 AE NH-12 AE N H-12 AE AE BE NH-12 EM-15U N H-12 BE EAE DAE EM-15U NH-12 NH-12 BE NH-12 AE AE 0 NH-12 NH-12 BE XF NH-12 X EM-14U 1.08 DA 11 AE a0 EM-15U EM-15U DE XG):( A 11 FXHIB EM-14U A-6 I DA EM-15U 1 O WALK-IN W5 I NL6 NL-25 COOLER A-7 1n��Q I I P20-----------I A-6 DA 1 R 0 1 NL6 NL-15 W51 I A-71 AE NH-12 1 AE 0 NH-12 DA EM-15U 1 1 E301 AE I I N NH-12 RA- RA-6 1 1 AE I NL6 NL-7 0 O DA 0 I I EM-15U Ll AE I EM-15U W5 O A-11 ;HEN DE 033 A-11 O ODE DE A-11 A-11 AN AN RA-10 RA-10 1.09 DEO DEO c RA-11 RA-11 d 01.10 AE NH-12 0 O A-71 4t xXF DA EM-14U RA-6 AN XF 1.04 4 A EM-15U OEM-14U 1 E301 AN I RA-10 FF- XF EM-14U TRUE PLAN B Ci {z ►— k NORTH NORTH X n FIRST FLOOR PLAN - AREA A - LIGHTING 1.11 1/8" =1 A" 1 / E202L SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD vv�vv CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & LJ DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.coi RD Project Number: 218092.00 G0NNF�T�'�, wig N0. 0033339 44/ ti O co O U^� W si O L U) W U Cn C- L U 2) L O^ CU W U i � O CU A., ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LOWER LEVEL AND FIRST FLOOR PLAN - AREA A - LIGHTING U Sheet Number: U Cn ca C__ E200L a. Q NO KEYED NOTES - a ;SHEET NOTES - W z m ry n ry �I 0 CNI W I-� U (D W U Cn 0 ICU CNI M C) 00 U 0 0 w 0 En r ti 00 r rn C) N - WP NL1 NL-1 vvP8 J NL-8 NL MCUH-13 NH-1,3,&NL4 NL4E301 NL3 NL-E301 E301 I I r_ NL� NL-11 NL2 NL-20 5 NL5 NL-5 I I NL3 NL-12 I NL3 NL-21 2 I E301 NH 7/9-1 r - NL2 NL-96 E301 NL3 NL-97 NL7 NL-9 NL-4 NL4 NL-13 NL4 NL-22 E301 NL1 NL-28 NL1 NL-37 NL4 NL-98 I I I NL5 NL-14 I NL5 NL-23 ( NL2 NL-29 I NL2 NL-38 NL5 NL-99 ® I NL7 NL-17 I NL7 I NL-27 NL3 NL-30 I NL3 NL-39 I I 2 NL7 NL-103 I I TDH NL4 L- 1 NL4 NL-40 I I I OS-17 N 3 I E300 NL5 N L-32 I NL5 N L-43 MVRVI � I ® I NL7 NL-35 I NL7 NL-47 I I TR MVRV-G I MVRV-G NL-6 8-H I MVRV-A OS-15 �I NL-16,18 q& NL-24,26 MVRV-G MVRV-G NL1 NL-48 ®MVRV-H L-----®---� ® ®---------------- ®NL-34,36 I ®NL-44,46 I I NL2 NL-49 50 NL-100,102 1- MBS MVRV-F NL3 NL-50 NL-28,30 I I I ® NL-54,56 NL4 NL-51 TECR �\ TR I NI F NI -F9 I �----------� TR �® EM-1 15 OS-20-------- OS-15 E303 TR TDH - MVRV-A ® MBS-A �(& NL MBS1, O GFI MVRV A 1 1 NL1 NL-57 ® ® NL-31,33 OS-20 OS-21 NI _1 nnoc nr1% ® Nil �1 12� NL-31,33 NL-31,33 TECR IVIL7 �7-a DD uIJ IVL-� I,JJ - EM-3 NL2 NL-58 ' ® ® NL-22,24 �NL-3 NL-3 GFI - - NL3 NL-59 I --------------------- MVRV-F TRW NL-26 NL-1 NL-1 MVRV-G MVRV-G� MVRV-G ®NL-62,64 NL4 NL-60 GFB NL-28, 0 ® NL 26 NL-92,94 NL-80,82 8 30 GFI TR I NL-72,74 + NL5 NL-61 NL-19 TRD NL-32 NL-4 ADD I ® I ® 1 NL7 NL-65 IVL-23,L5 - `�^f,_1 �9 OS-16 GFI , , I ® MVRV-A OS-43,45 TUR ® NL-28,30r - - - - 13 TDH E303 OS-19 W NL-3 NL-5 DD OS-18I GFB TRW TRD ®� NLA OS-16 I NL1 NL-75 I NL1 NL-66 NL-21 GFB NL-27 29 I I m 6 d -4( NL1 NL-87 I NL2 NL-76 I NL2 NL-67 GFI 'd GFI I I MVRV-A I NL3 NL-88 I NL3 NL-77 I NL3 NL-68 E 00 N L-26 N L-26 N L-4 N L-22, 24 N L-4 NL4 N L-78 NL4 N L-69 J I NL4 NL-89 I NL5 NL-79 I NL5 NL-70 GFI NL5 NL-90 NL7 NL-85 N17 NL-73 NL-7 GTR 7n!L N FI -93 I �� I �� - - - - - - ` „1 , 5 2 NH/1-1 (480Y/277V NORMAL) SOS-15 MEWH-2 I YE311 I E301 I E301 I NL/L-1 (208Y/120V NORMAL) NH-11,13 I NUL-2 (208Y/120V NORMAL) TCD ® - - - - - - - - i - - I - - EM/1-2 (208Y/120V EMERGENCY) NL-11,13 GFI - - - ® J_ - - - - r OS/1-2 (208Y/120V OPTIONAL STANDBY) ® ® NL-9 ® NL-22,24 I NL1 NL-104 I WP MVRV-A TCD ® MVRV-A TR NL2 NL-105 GFI NL-22,24 NL-15,17 NL-22,24 NL-4=I NL3 NL-106 I NL-6 NL4 NL-107 TCW TCW m TECR lNL5 1 W-108 GFB GFB I I �� EM-5 I NL7 NL-111 I %H NL-7 NL-7 GFI NL-16,18,20 NL-10,12,14 4 � NL-9-4 ® ® I I I TRUE PLAN NORTH NORTH T MVRV-E 2 I I /�� /-I`\ LOWER LEVEL PLAN - POWER r NH/1-1 (480Y/277V NORMAL) I `e NL-110,112 E301 1/8" =1' 0" B v NULA (208Y/120V NORMAL) NUL-2 (208Y/120V NORMAL) 4 EM/1-2 (208Y/120V EMERGENCY) E303 OS/1-2 (208Y/120V OPTIONAL STANDBY) L - - - - - - - - J 0 � NH/1-1 (480Y/277V NORMAL) NH/1-1 (480Y/277V NORMAL) NL/1-1 (208Y/120V NORMAL) NL/1-2 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) EM/1-2 (208Y/120V EMERGENCY) U011 2(2VSY/12VV %Jr 1 VALS1MINDBY) I VS/I 2(2VSY/12VV VPIIUINALSTANDBY) I v""vP TRW 1. E.C. SHALL PROVIDE 4"X4" JUNCTION BOX ABOVE ACT CEILING FOR THE INSTALLATION OF EMERGENCY CALL REPEATER. E.C. SHALL HARDWIRE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE THE FIINIAL I NSTALLA I IV V f�CCQLJIRCIVIEIVTS V�'ITH APPROVED LOW VOLTAGE VENDOR. NL- NO NL-1 ®�---�------------ I 5 I TR NL-91 2 I 2-----------L- NL2 NL-2 NL-88 r NL1 NL-19 E301 NL3 NL-3 I I E301 NL1 NL-1 I NL1 NL-10 E301 I MEWH-3 ® NL1 NL-10 NL 12 I 2 I NL2 NL-20 I 5 ( NL4 NL-4 ( TRD ® NL2 NL-2 NL2 NL-11 A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL PCSI I IVIV Ur I fulE CIRCUIT BREAKERS 1 V TnL-- PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. C. ALL208Y,120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' PANEL NUL-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL COMMON OR PUBLIC SPACES SHALL BE FED FROM 'NU PANEL NUL-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL AS NOTED. F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING A nrA nI I/ %A IAI n1 I A I I nr rrr-Y rn/1nA Iwll I I"IA Airl n An AI/1Trn /'lRE/-1 JI"IUVVIV JCIHLL BE FED I-ROIVI IVL 1"MIVCL0, HJ IVU 1 CU. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED, H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. I. E.C. SHALL REFERENCE LOW VOLTAGE 'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR AI I FINAI ROI K'H-IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEMS SHALL INCLUDE: - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE -TELECOMMUNICATIONS, DATA NETWORK - EMERGENCY CALL SYSTEM - CABLE TELEVISION -AUDIOVISUAL, SOUND SYSTEM - WIRELESS NETWORK - EMERGENCY TWO WAY COMMUNICATION SYSTEM J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. SHALL PROVIDE 208Y/120V AND 480Y/277V NORMAL POWER, ESSENTIAL POWER AND NON -ESSENTIAL POWER, AS REQUIRED FOR A COMPLETE AND OPERATIONAL LOW VOLTAGE SOLUTION. K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENT POWER CIRCUITS. L_. E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. COORDINATE EXACT LOCATION OF POWER CONNECTION WITH APPROVED FIRE PROTECTION SYSTEM CONTRACTOR. NH-2,4 8 NL3 NL-21 NL4 NL- I I NL5 NL-5 I® NL-95,97 TRW I NL3 NL-3 I NL3 - 2 r - - - - - - - - -- - - I E301 NL4 NL-22 I E301 NL3 NL-12 NL7 I NL-9 I I NL4 NL-4 NL4 NL-13 E301 NL1 NL-19 I NO NL-28 E301 N NL5 NL-23 NL4 NL-13 TRD L-93 NL5 NL-5 NL5 NL-14 NL2 NL-20 NL2 NL-29 2 I NL7 NL-27 I NL5 NL-14 I ® NL-99,101 I NL7 NL-9 I NL7 NL-17 NL3 NL-21 I NL3 NL-30 I 2 E300 I I NL8 NL-28 I NL7 NL-17 TR ' I NL4 NL-22 I NL4 NL-31 I E300 NL-88 I ( NL5 NL-L3 I NL5 NL-32 I I I - -I NL7 NL-2 I NL7 NL-35 I I MVRV I I � ®I I I NL-6,8 MVRV-B I- MVRV-G MVRV-G 1 m L-6� I I NL-6,8 I NL-16,18 I NL1 NL-29 W NL-90,92 NL2 NL-30 I I MVRV-I I MVRV-H � I I NL1 NL-37 o MVRV-G MVRV-G NL2 NL-38 I NL-34,36 I I NL-24,26 I m NL-16,18 - - - - - - - - - ` _® MBS-B `� - - - - - - - - �� - - - - ®- - - _ ®NL-24,26 I NL-34,36 I I MVRV-F NL3 NL-39 NL3 NL-31 1�► t (� NL4 NL-33 ® I I ® I I NL-90,92 � I I I I NL-44,46 NL4 NL-40 TR I 14 ®MVRV-A TR NL5 NL-43 nn nn -3� --I- - - - - - J I 11."11.� I 1 �-==�TR=-==----- � -- NL-90,92 TR � --- ------ �- I i i 1 s ne_�� ____ nn _an a� nc-�d MVRV-A _ _ _ _ nn nI1 n� - vv-LL - I Vt--v , l) vv ')A �- - R -- � � IVLI IVL-`71 �- I TR OS-24 N TR TECR OS-22 OS-22 I C NL1 NL-38 - - W EM-7 a NL2 NL-39 MVRV-G I ® MBS-B NL3 NL-40 NL-46,48 NL-58,60 NL4 NL-43 ® MVRV-G NL5 NL-44 y NL-54,56 NL7 N L-47 I I-DD OS-23 t I I 2 NL1 NL-49 E300 t NL2 NL-50 NL3 NL-51 t NL4 NL-52 I TRF L NL5 NL-53 GFB _----®®®---` NL7 I NL-57 5 INL-67 I E301 I L------- - I'�=NL-63 9 NL-59 NL-59 N L-59 6 ItGFI N L-63 ® MVRV-A I MVRV-A OS-24 1 TE R MBS-A ® 1-2 -� MBS-B �® EM-17 NL1 NL-48 NL-58,60 DD DD NL-87 ® NL-90,92 NL-90,92 NL-90,92 I MVRV-F NL2 NL-49 TDH OS-27 NL-87 ® NL-54,56 GFI NL-86 r��* NL3 NL-50 NL4 NL-51 NL-61 ® NL-90,92 NL-86 6 I MVRV-G NL5 NL-52 DD OS-26 GFI NL-80,82 MVRV-G MVRV-G I I NL-62,64 NL7 NL-55 I TECR CARE NL-89®I NL-72,74 NL-61 6 GFI GFI NL-61 NL-61 I TDH EM-91 ®� PARTNER GFB i ®OS-30 Vrr DD OS-28I I I NL-69 W MVRV-A MVRV-A NL-69 ® NL-58,60 =@ NL-71 TR OS-22 NL-89 6 NL-87 6 OS-26 - I NL1 NL-66 NL1 NL-57 NO NL-75 I NL2 NL-67 I NL2 NL-58 2 NL-58,60 MSB B TDH � NL2 NL-76 NL3 NL-68 NL3 Nil-59 E3001 GTCL MVRV- NL-65W NL-58,E 60" AFF MVRV-1 TV =@=@ NL-58,E NL-65 NL-65 6 N L-63 ® NL-58,60 OS-29 ® OS -DID I NL3 NL-77 I NL4 NL-69 I NL4 NL-60 r Nil Nil -78 I -NL-71 I I LN L5 NL-70 I NL5 NL-61 NL5 NL-79 L7 NL-73 NL7 NL-65 II I NL7 NL-79 5 I 2 I 2------------J GFI TDH I I E301 I E301 NL-691 I NL-71 OS-31 OS-24 E301 I NH/1-1 (480Y/277V NORMAL) --6 -- ® ( NORMAL) r�------------®--®-�- -' I - -� EM12( 08Y/20VEM! RGENCY) I - - - - J_- - - - J OS/1-2 (208Y/120V OPTIONAL STANDBY) I I I I NH/1-1 (480Y/277V NORMAL) 2 NL/1-6 (208Y/120V NORMAL) E301 I EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) I I� i NL1 NL-1 L4 ® I I NL2 NL-2 NL 69 I I I ® NL3 NL-3 - - MVRV-E NL4 NL-4 TR NL-8,10 NL5 NL-5 SOS-39 I NL7 NL-9 I ® ® ® I I MVRV-A NL1 NL-10 \� I ®44,46 I MVRV-E NL2 NL-11 I NL-16,18 NL3 NL-12 NH/1-1 (480Y/277V NORMAL) PWH-1 PWH-2 PWH-3 PWH-4 I ® NL4 NL-13 NU1-K (208Y/120V NORMAL) NL-75 NL-77 NL-79 NL-81 I MVAV-1 I TECR I NL5 NL-14 EM/1-2 (208Y/120V EMERGENCY) N41 H/1--1 I �EM-11 I NL7 NL-17 OS/1-2 (208Y/120V OPTIONAL STANDBY) I I I I ri I I ® I I MBS-A 2 1I DISHWASH I NL-44,46NH/1-1 (480Y/277V NORMAL) I E301 NU1-K (208Y/120V NORMAL) I 103/ It EM/1-2 (208Y/120V EMERGENCY).- OS/1-2 (208Y/120V OPTIONAL STANDBY) I I I 5 1 NH/1-1 (480Y/277V NORMAL) q MVAV-1 I TR I E301 NL/1-6 (208Y/120V NORMAL) TR TR TR I NH/1-1 I OS-39 EM/1-2 (208Y/120V EMERGENCY) NL-29 NL-29 NL-29 16,18,20 OS/1-2 (208Y/120V OPTIONAL STANDBY) r MVRV-E NL1 NL-19 1 I I ® NL-24,26 NL2 NL-20 E304 I I NL3 NL-21 MVAV-3 MVAV-4 NL4 NL-2 PRIVATE II ® ®NH/1-1 I I NL5 NL-23 I NH/1-1 NL7 NL-27 DINING I EXHIB Vv,,I 1 17 19 1032 KITCHEN STATIO MVAV-6 TR TR MVAV-5 �NLL-29 N L-29 1033 10 I NH/1/1 NH/1-1 tlU � �---------- 21 --- 22,24,26 NH/1-1 (480Y/277V NORMAL) NL/1-1 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) ®MVRV-A NL-58,60 ®TDH O S-25 (sN L-69 WP =0 NL-73 MUH-1 NL-70,72,74 PCP-1 PC[ N L-76 N L- TRUE PLAN NORTH NORTH FIRST FLOOR PLAN - AREA A - POWER 1 /8" =1'-01, MVRV-O OS-15,17 1 / E202P %SUMMIT ,SM11 M DEVELOPMENT 241 N, Brnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD UUINO I KUU I IVIV or-mvl r-0 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 r_" nnn nn • nn.I n r' aX: 920-924-29 " 0 Website: www.cdsmith.com 0 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-30 70 DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.17001 Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 I00N/vEC''%. 4 �•' vHEn ' T/n . 41 k, m I yNp4� , p033339 I � 1 i ` z c O O U O W O (D U 2) L N O U o Q, ZD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LOWER LEVEL AND FIRST FLOOR PLAN AREA A - POWER J J U N Q Sheet Number: C_ U aE200P O PRTSUMMIT SMITH F: L11 Z m ry �I 0 N U E301 I SP SP 1 E301 I I I I I I I I I I I 1 I I I I I SP oa HV1/C V 02/C 0 0 pF SP HC QP HV1/C 00 CO ❑F VO 1 /C SP SP ❑F a HV2/C V02/C HC FF� ❑F HC [ECM SP ❑F HV1/C SP ❑F HV1/C ❑F ❑F SP SPA � I � I i r-----r-----i -I L- — — -I I E301 I E301 I i I 3 I 3 I r----------� E301 I E301 I I I I I 3 1 I I I P �I I I I E300 I I I 1 I I I I I I I I I I I I I SP L------------------J ® I 0o SP I HV1/C ❑F ❑F PS 0 TS FS 0 SP V01/C o CARE i PARTNER 0011 MEDS 0 V02/C VO 1 /C PS nn Vol I 6 I I E301 I I I I I I I I I I I I HV1/C SP Soo ---- HV1/C I I I I I I I I I I I I I I 3 1 I I I � E300 I 6 1 3 1 j I svi tsuE301 ' I I I I ---------1-- — I — —J TRUE PLAN NORTH NORTH LOWER LEVEL PLAN - TECHNOLOGY 1/8" = 1'-0" r I 6 I 9 E301 I E301 I 6 I E301 I I I I I I I I SP I I I I ° I I I I------------------------1 Soo a Sao HV1/C SP HV1/C In HV3 ❑F Fp O WP MM MM V02/C 0 SP SP 0 SP 00 V01 /C CO SP ooa HV1/C SO 10 HV1/C HV1/C PRIVATE DINING 1032 EMERG POWER 1041A HV2 ❑F 0 HV2 PS ❑F 0 SP ❑F HV2/C SP � I � i 3 I 3 I— _�------r-----L— — HC 1 E301 I E301 0 1 I 3 I 3 1 r------------� V01/C I I E301 1 E301 I 1 I i I I I 3 I I I I E300 I 1 SP o f I I 1 I I L---------I--------- I I 1 I a o a SP HV1/C SP a SP V01/C SP SP a a ° ° V01/C V01/C nF0 COO V02/C SPV01 /C QF a HV1/C 0 0 TS FS SP 0 HV1/C P 0 SP F I i 0 3 HV3/C I E301 I i o SP WALK-IN COOLER 1035A IF HV1/C I I I I I I HV1/C SP I 3 E301 H 2/C DISHWASH I 103; CORD: 4-------------� I 6 I I E301 [E]SP I ❑F VO1/C HV3/C HV1/C 0 o I SIP I I EXHIB KITCHEN OR 1033 HV1/C OV02/C L------------J 1 I 1 I I SP I1EI---------------------J °S I I HV1/C SP SIP OD-------- HV1/C 1 I I I I I I I I I I I I I I 1 I I I 1 I I I I j 3 1 E300 I I I I I 6 I I 3 E301 I 3 I I E301 I E301 I TRUE PLAN NORTH NORTH FIRST FLOOR PLAN - AREA A - 1 /8" =1'-0" DEVELOPMENT 241 ICI Rmnr4uunx Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com �JJCD LA MN�Tm CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com .'ct ,ec1s L 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & Li. -A DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414,778.23601 r-d@ringdu.cor RD Project Number: 218092.00 `a �G % •d �. No. 0033339 seo ca o C) 0 � U 0 L � > -,` W n O U) C L U 2' L O N W U o C = a ZD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LOWER LEVEL AND FIRST FLOOR PLAN -AREA A - 'TECHNOLOGY v a> Q Sheet Number: CU Y E200T O F F `SHEET NOTES - W lei LO M M N O N N OD:_ RA-40 LB RA-14m T T XG DA DA EM-14U O RA-13k O RA-13k /-\P11 RA-13 DA DA O RA-13k O RA-13k PA 3 -\RA-1 DA DA O RA-13k O RA-13k XG y y EM-14U LB RA-14m 0 RA-40 XF EM-14U - 01.15ODA 1.14© J T EM-16U DA DA P20 DA DA o EM-1XF P20 0RA-20 OEM-16U IRA_20 ORA-20 OEM-16U W XF )K "20 EM-14U XFO DADADA DA DA ©III DIDEM-14U � ORA-23x 0RA-23x OEM-16U 1.17........ ORA_22 XF XT DA EM-14U EM-14U RA-22 O DA DA DA DA DA O RA-23x O RA-23x O RA-23x O RA-23x O RA-23x LY LY w 17 RA-21 LX ®):� DA O RA-21 w CKI P 17 RA-22 XF DA DA DA DA DA RA-21RA LY _ EM-14U O RA-23x O RA-23x O RA-23x O RA-23x O RA-23x P 17 RA-21 w Ll RA 20 RA-21 DAO J RA-22 O O-DD O O XF O DA XF DA DA DA RA-21 RA-22 EM-14U EM-16U EM-14U OEM-16U 0RA-22y OEM-16U LW LW P9 RA-15n RA-15n -�-�R -10 RA-21 XK �DA OPR9A_19):�P`2 ODODA DA�RAgRA_23xA_23x RA-22y ORA_22y EM-14U ORA-19 ODA RA-20 F-IAA RA-19 NH-10 Q QP9 oOA DD DD /-\RA-19 DA DA DA DA RA-40 r n An DA_'I0 r%_. n_. /'1_ _ r1_ I � 11.13 - I y °' KA-23x 'a KA-23x `' RA-22y "KA-22y DA DA DA DA DA O RA-20 ONH-10 ONH-10 ONH-10 ONH-10 W 21 'BRArW321 DA DA XXF �,Li-,,DBROOM ' ONH-10 ONH-10 DA DAO EM-14U DA DA DA DA DA O A_20 EM-16U OEM-16U O RA-26t O RA-26t DA ONH-10 ONH-10 DA .18 0NH-10 W2 W2 ONH-10 0 t OS B NH-10)ZO ONH-10 OS B W2 W2 FC NH-10 NH-10 NH-10 W2I W2 O DA NH-10 NH-10 DA DA B ONH-10 ONH-10 EM-16U OS DA n -619 EM-16U DA RA-20 OA o AA P20 P20 AA RA-1 C__ .]NH-10 RA-20 DA � RA-20 NH-10 D o RA-20 EM-14U JB J� DA EM-16 EM-16U AA P8 P8 P8 Jg O [2 NH-10 RA-35 RA-35 RA-35 EM-16 EM-16 XF 1.16 OA p GFI IKEM-14U OS B RA-40 XFX FC DA DA DA EM-14U NH-10 O RA-35z O RA-35z O RA-36 O DA 0 EM-16U XF DA EM-14U ©1.19 EM-14U DA DA OA o 38( OEM-16U O RA-35z O RA-36 DAO XF RA-40 P7 P7 P7 P7 EM-16U O EM-14U OD — — R"-�,36 A3636 !' RA-LY LY RA-28q RA-28 -40 _ _ _ _ _ DA DA DA DA DA LY � W q r O RA-36 O RA-36 O RA-36 O RA-36 O RA-36 Q -28q � XF - I % DID DID DID DA DA FH EM-14U I E301 I 4 RA-36 4 RA-36 4 RA-36 RA-31 O RA-31 ---------� EM-16U I NL6 NL-10 I DA z 1.35 EM-16U I I ORA-36 © D I M-16U O E300 I I I B XG I I ❑CA OS ❑CA QDD EM-14U NH-10 NH-10 RA-30 MRA-30 DIDFH I I-0RA-30 O EM-16U FH I I B �S DA EM-16U ❑ CP ❑ CP 01.20 RA-30 NL6 NL-17 XF I I NH-10 NH-10 DA DA EM-14U� ODA RA-30P3 RA-30 -16UP3 �1.23------- W5 ----� XG RA-30 RA-30 P20 RA- EM-14U RA 33 ):�EM-14UFDA DA3 P20 DA 20 DA DA O T OEM-16U �-34 ORA-34 �RA_34 OEM-16U )ZA-34 OEM-16U8( 'P20 EM-16U P20 5 RA-31 U W5 RA-34 _ _ _ _ _ _ _ )9 RA-33 ©1.22 NL6 NL-25 9RA-33 CP �CP DA NH-10 NH-10 ORA-31 AA I NL6 NL-38 I BUSINES:: OS g OS gNH-10 I I OFFICE i CP CP WAIT STATION 10 ® LB RA-14m LB RA-14m R 1.12P DA DA DA DA DA DA +C— A-18a RA-18a R0 RA-18a RA-18a RA-18a RA-18a SH O P13 DA RA-16 RA-18a ):�P 13 ):�P`13 P13 RA-16 RA-16 RA-16 O O O O O O O DA DA DA DA DA DA DA RA-17b RA-17b RA-17b RA-17b RA-17b RA-17b RA-17b LW LW RA-15n RA-15n O LB RA-29s AA NH-10 1NH-10 P20 OD NH-10 M-16U DA 0 7 I I I RA- E300 I I I NH-1 H 0 I I I O DA -10 1.21 AA NH 0 Oa ----------� NH-10 I 7 I -�- E301 DA 0P6\ NH-10 NL-99b DA ❑ ❑ --- ---J O OSg ONH-10 CP OS B CP P6 NH-10 NH-10 NL-99b ❑ O DA O DA NH-10 NH-10 CP CP NH-10 NH-10 TRUE PLAN NORTH NORTH FIRST FLOOR PLAN - AREA B - LIGHTING 1l8" = 1'-0" OB O RA-1 OB O RA-1 OB O RA-40 DA O RA-31 OA RA-1 �P14 RA-24 P14 - RA24 DA DA DA O RA-26t O RA-26t O RA-26t P14 RA-24 P14 OA DA DA RA-24 o RA-40 OEM-16U O RA-26t O DAXK EM-16U EM-14U DA DA DA O RA-27v O RA-27v O RA-27v OA RA-1 MA-25 - M RA):=25 DA DA DA O RA-27v O RA-27v O RA-27v \� P14 () RA-25 P14 OA DA DA XK o RA-40 OEM-16U 0RA-27v ODA E -14U EM-16U 10 LY LY r RA-28q WB RA-28q RA-31 — WI31�G L KA-3 I ] A t L_VV O RA-28r DA DA RA-31 RA-31 LW �2�O LW RA-28r DA RA-31 RA-28r O RA-31 DA RA-31 DA OEM-16U LB I RA-29s LBIRA-29s LB RA-29s Il DA OEM-16U RA- RA- --(31 XF O EM-14U DA O RA-32 O DA EM-16U P1 RA-32 DA 0 0 DA EM-16U RA°2 OB O RA-40 LW RA-28r LY R,�-28q DAO RA-31 ❑CP ❑ DA RA-31 O DA OEM-16U DA O EM-16U RA- RA_31 DA OEM-16U DA P20 OEM-16U):�RA-31 NH-10 CP N H-10 El CP F NH-10 OS B IP NH-10 71CP NH-10 AA CP NH-10 NH-10 C] os B DID DID b RA-31 b RA-31 XF )E( EM-14U )"` P20 � RA-31 QDD (QDD EM-16U RA-31 AA NH-10 B OS H I I� b DA ONH-10a DA ONH-10a DA NH-10a OS P6 BON L-99b O DA O DA O NH-10a NH-10a DA NH-10a OB O RA-1 OB O RA-40 CP CP NH- NH-10 OS B 1 CECP NH-10 NH-10 F F CID NH-10 NH-10 1. REFER TO ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR EXACT LOCATION OF ALL ELECTRICAL DEVICES PRIOR TO COMMENCING INSTALLATION 2. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE AC I UAL POSI I ION OF T HE CIRC UI I DRE/FiKERS IIV T HE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. 3. REFERENCE SHEET E102 FOR PANELBOARD BOUNDARIES INDICATING PANELBOARDS SERVING THIS SPACE. 4. ALL 480Y/277V, NORMAL BRANCH CIRCUITS 'NH' FEEDING AREA SHOWN SHALL BE FED FROM "NH" PANELS, AS NOTED. 5. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NU PANELS, AS NOTED. 6. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. 7. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. 8. "RA" AS IN "RA-**" INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/1AL UNLESS OTHERWISE NOTED. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 9. ALL EMERGENCY BATTERY UNIT (EBU) LIGHTS SHALL BE 1A/IPFD TO I INIC1A/1T('I4ED I IGI—ITII:I(; ('.IP(:I IIT.qFRVINr� TPF= AREA WHERE EBU IS LOCATED. (EYED NOTES - a 1. TYPE "LA" SHALL BE MOUNTED AT THE BOTTOM OF SIGNAGE, AIMING UP AT SIGN. TYPE "LA" SHALL BE ADJUSTABLE LINEAR FIXTURE, AIMING AT THE BUILDING SIGNAGE. REVER TO DETAIL B4 AND B5 ON SHEET A402 FOR MORE INFORMATION. 2. REFER TO DETAIL 1/E501 FOR MORE INFORMATION. 3. REFER TO DETAIL 2/E501 FOR MORE INFORMATION. 4. REFER TO DETAIL 3/E501 FOR MORE INFORMATION. 5. TYPE "LB" SHALL BE MOUNTED AT HORIZONTAL TRIM, HIDDEN FROM VIEW WITHIN COVE, TO UPLIGHT WALLS, TYP. 6. REFER TO DETAIL B1/ ID801 FOR "PT' MOUNTING HEIGHT. 7. REFER TO DETAIL Al AND B6 ON SHEET ID801 FOR "P17" MOUNTING HEIGHT. 'SUMMIT SMITH DEVELOPMENT 741 N, Rr�adway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D UUIVj I KUU I IUIN btKVIUt0 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 I Fax: 414.778.23601 r-d@ringdu.col RD Project Number: 218092.00 `\0„ G 0 N N i �. No_ 0033339 " w ` I R\� lei, O O U 0 O W 0 A Cn CU N L U O N W U � � O TTCU - P-4 ...1� Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: FIRST FLOOR PLAN - AREA B - LIGHTING <Sheet Number: C_ U a c6 E201 L C CL n P. w z M O IY ry rn I 0 CVI w I -I U O u-I U 0 L_ cry A M d- d- M CV rn 0 N N 7 PRIVATE DINING 1032 EXHIB KITCHEN 1033 WAIT STATION 1034 WP TR TR NL-35 TR NL-33 NL-33 N L-31 VTR N L-31 Imo,_ L 4D r D A TR N L-33 TR NL-31 T o- TR TR TR MVAV-7 ® TR NL-31 NL-33 NL-33 NH-23,25,27 DID WP =0 6 NL-32� N L-35 TFP TFP *--.000, 4 TFP1 TFP1 NL-28 NL-30 MBS-A ® OS-33,35 SH,c =@ 60" AFF TR ® TR ® TV �nn\/Ax/-8 NL-36 ® TECR NL-34 NI -34 `mom' NH-29 TR EM-2 TR NL-32 � NI -2 '; TR-� SH,c SH,c TR NL-36 TR MVAV-9 ® NL-34 NH-28,30,32 NI/1-1 (480Y/277V NORMAL) SH,c SH,c MVRV-J NL/1-6 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) TD TD 11\ 11\ NL-36 NL-36 I r.ii _1;7 rO OS/1-2 (208Y/120V OPTIONAL STANDBY) 6 6 I NI/1-1 (480Y/277V NORMAL) NL/1-5 (208Y/120V NORMAL) GFI GFI EM/1-2 (208Y/120V EMERGENCY) NL-43.& NL-43 OS/1-2 (208Y/120V OPTIONAL STANDBY) TEWC ® ® TEWC GFB GFB N L-45 N L-47 TR GFI �NL-49 N L-43'W T SP-2 'C' NL-47,49 GFI NL-101 Nil rR 6 IVL-J 1 TR TR NL-51 WP �NL-51 N L-50 TDH 1017 ®OS-37 TR N L-49 m nngc ;c\ NL-57,59 TR OS-32 �TR ^ U 0-32 m MVRV-A 4!W NL-38,40 ®MVRV-N OS-33,35 VTR r--�--� V 5-34 I 2I I E305 I I I 1 I I I I I I I I I 1 I I I ®EPO = WP N L-48 ® MVRV-M OS-33,35 0 NH/1-1 (480Y/277V NORMAL) TR TR TFPT NL/1-6 (208Y/120V NORMAL) OS-34 OS-32 6 EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) _TTR A � � 5 NL-44 NRL44 NH/1-1 (480Y/277V NORMAL) NH/1 E303 MVRV-N NL/1-5 (208Y/120V NORMAL) T ivy-57,59 r FM/1-2 (208Y/170\/ EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) ®TECR EM-4 © AB TR WP N L-44 L-48 24 J ^ ^ � uu �N rt- N L-44 TR N L-44 N L-49 =:@ 24" �---� NL-49 TR 2 - - � �NL-46� E303 ^' 6 A � 1 I®�� � B DID TR NL-46 MVRV-R ED NL-49 4® - J MVRV-N ® NL-57,59 TECR NL-61,63 60"AFF EM-6 TR TV WP 6 1 � E305 I ® MEWH-4 I - - NH-6,8 I s NL1 NL-1 MVRV-K E301 NL2 NL-2 ® NL-61,63 I NL3 NL-3 N L4 N L-4 - - - 2 I NL5 NL-5 FEM-24 10 GEN24 AFF NL7 NL-9 All O 1 All 4n AAII IAI DD I IIVLOIIVL-IV I "�� NL-71 - - MVRV-L NL1 NL-11 97-80 NL-61,63 NL-71 I NL2 NL-12 ® I ® MVRV-I I� NL3 NL-13 MVRV-I I I NL-6,8 I NL-73 24" AFF NL4 NL-14 NL-73 NL-16,18 I---------� NL-71 I NL5 NL-15 - - - - ®MBS-A NL7 NL-19 I MVRV-A MBS-B MVRV-A NL-70,72 NL-70,72 ® NL-70,72 ® NL-70,72 NL1 NL-20 MVRV-H TECR TR TR TECR EM-8 6 OS-36 (5OS-36 EM-10 NL2 NL-21 NL-26,28 ------------- NL3 NL-22 ® I I- 9 NL-75 MVRV-L NL4 NL-23 NL5 NL-24 NRL-64 NMVRV-HRL-64 I ® I ®NL-70,72 I I NL7 NL-27 $-_ I NL-34,36 I� DID DID ®MVRV-A TRD I ® OS-38 OS-38 NL-70,72 NL-56,58� MVRV-A NL-70,72 TRW N L-75 TRID GFB ®I NL1 NL-29 I 6 2 NL 60,62 I NL-52 I NL2 NL-30 160" AFF E300 TRW® NL3 NL-31 TV NL-77 MVRV-J I1$1--TR GFB I NL4 NL-32 I NL-77 ® NL-70,72 N L-54 NL5 N L-33 - - - - - - - - - NL-64 I NL7 NL-37 8 I-ONFERENCE NL8 NI-38 E301 I 1008 � N L-75 NL-7�7 ---5 l'UD @--NL-79 N L-77 N L-756 TRUE PLAN NORTH NORTH FIRST FLOOR PLAN - AREA B - POWER 1/8" =1'-01, �WP NL-69 ®MBS-A NL-70,72 TR N L-46 N L-466 6N L-46 W P L-48 I F TR TR 'W �N NL-76 TFP1 NL-76 -6- NL-78 TFP N L-92 NL-92 TR TR DID NL-76 NL-76 OS-48� ® FB FB TR ®I A I NL-76 DDT ® MVRV-A NL-92 OS-48 ®MVRV-L NL-65,67 NL-65,67 TR NL-92 6 N L-76 ® FB A TR N L-92 NL-74� FB A TR UriA N U N L-76 LOBBY MVRV-L 1001 'd NL-65,67 TR ($N L-74 ®MVRV-L NL-66,68 MBS-A ® NL-66,68 NL-74 MVRV-K ® NL-66,68 TR FA TR NL-74 TDH2 NL-i OS-50®® ANUN NL-79 OS-4.2 � MVRV-J NL-65,67 N L-94 DID ® SH OS-52 CUH-2 NL-86 NH-31,33,35 N L-79 6 8 NL-90 q MVRV-J ® NL-66,68 PSH NL-90 DDT NL-86 OS-46 MARKETIN( 60 AFF 1004 DDT EDTvOS-46 NL-86 NL-90 TDH2 NL-86 TUR NL-90 ®OS-44 NL-88 WP NL-69 I NI/1-1 (480Y/277V NORMAL) NL/1-5 (208Y/120V NORMAL) EM/1-2 (208Y/120V EMERGENCY) OS/1-2 (208Y/120V OPTIONAL STANDBY) _SHEET NOTES - /VSUMM_ IT_ A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND v ►S�MI T H FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING DEVELOPMENT HEIGHTS OF ELECTRICAL DEVICES. B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE 941 N Rrnarlwnv ACTUAL POSITION OF THE CIRCUIT BREAKERS IN THE Suite 400 PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES Milwaukee, WI 53202 ARE CONNECTED TO A COMMON CIRCUIT. Phone: 414-453-0110 C. ALL208Y,120V, NORMAL BRANCH CIRCUITS'NL' FEEDING Fax: 414-453-0112 LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' Website: www.summitsmith.com PANEL NL/L-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS'NL' FEEDING LOWER LEVEL COMMON OR PUBLIC SPACES SHALL BE FED FROM 'NL' PANEL NL/L-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL Cm D AS NOTED. r5mm[Tm F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS'NL' FEEDING I.VIVJ I htUl� I IVIV ^Cmx iioMvIICJ AREA SHOWN SHALL BE FED FROM NL PANELS, AS NOTED. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" 889 E. Johnson Street FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' Fond Du Lac, WI 54936 PANELS, AS NOTED. Phone: 920-924-2900 Fax: 920-924-2910 H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" Website: www.cdsmith.com FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. I. E.C. SHALL REFERENCE LOW VOLTAGE 'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR ALL FINAL ROUGH -IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEMS SHALL INCLUDE: - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE -TELECOMMUNICATIONS, DATA NETWORK - EMERGENCY CALL SYSTEM 209 South Water Street - CABLE TELEVISION Milwaukee, WI 53204 -AUDIOVISUAL, SOUND SYSTEM -WIRELESS NETWORK Phone: 414-359-3060 - EMERGENCY T rVO vvAY COMIVIU11411CA T ION SYS T EIVI Fax: 414-359-3070 J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. 480Y/277V NORMAL P ESSENTIAL PIOWER DE AND NON --ESSENTIAL POWER, ROWER, RING In iG Q REQUIRED FOR A COMPLETE AND OPERATIONAL LOW DUCHATEAU VOLTAGE SOLUTION. 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.cor K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL RD Project Number: 218092.00 AccicTF=n LI\/IN(; ANIn 11/Ir=mnRY (_ARF RFCIDFNT APARTMENT POWER CIRCUITS. L., E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR \\�\„ 1 1 l 1111 f COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. `\�.�QF-GONAI, COORDINATE EXACT LOCATION OF POWER CONNECTION WITH APPROVED FIRE PROTECTION SYSTEM CONTRACTOR. ► •d ', No. o033339 (KEYED NOTES - C-_-J 11. SWITCH FOR COURTYARD FIREPIT SHALL BE RATED FOR ► ��� ON/OFF CONTROL. COORDINATE REQUIREMENTS WITH APPROVED FIREPIT MANUFACTURER. 2. EMERGENCY POWER OFF BUTTON WILL INTERFACE WITH THE FIREPIT SHUTOFF SOLENOID AND SHUNT TRIP BREAKER TO REMOVE BOTH GAS AND POWER FROM THE FIREPIT IN AN EMERGENCY CONDITION. REFERENCE FIRE PIT DETAIL ON SHEET E510 FOR ADDITIONAL INFORMATION. �i. E.C. SHALL PROVIDE 4" X 4" JUNCTION BOX ABOVE ACT CEILING FOR THE INSTALLATION OF EMERGENCY CALL REPEATER. E.C. SHALL HARDWIRE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE FINAL INSTALLATION REQUIREMTNS WITH APPROVED LOW VOLTAGE VENDOR. 4. EC. SHALL PROVIDE (1) 1 INCH CONDUIT FROM FLOOR BOX LOCATION TO NEAREST FULL HEIGHT WALL FOR ROUTING OF POWER CIRCUITS. 5. E.C. SHALL PROVIDE (2) 1 INCH CONDUITS FROM FLOOR BOX LOCATION TO NEAREST FULL HEIGHT WALL FOR ROUTING OF POWER/DATA/TV CABLING. Ei. E.C. SHALL PROVIDE 1"C FROM INSIDE CABINETRY TO A SINGLE GANG JUNCTION BOX MOUNTED AT 60"AFF BEHIND WALL MOUNTED TELEVISION. PROVIDE PULL STRING FOR FUTURE INSTALLATION OF LOW VOLTAGE CABLE CONNECTION BETWEEN CABINET LOCATION 7. DUPLEX RECEPTACLE SHALL BE MOUNTED WITHIN CASEWORK FOR FUTURE AUDIO EQUIPMENT. COORDINATE O INSTALLATION OF POWER AND SDATA WITH CASEWORK AND SHELVING. C:) 8. E.C. SHALL PROVIDE 2-GANG RECESSED MEDIA TYPE U OUTLET FOR POWER/TV/DATA CONNECTION. Q� MANUFACTURER SHALL BE LEVITON 690W SERIES OR p EQUAL. REFERENCE LOW VOLTAGE DOCUMENTS FOR n ADDITIONAL INFORMATION. 9. FIRE ALARM ANUNCIATOR PANEL. COORDINATE FINAL LOCATION WITH FIRE INSPECTOR PRIOR TO INSTALLATION. REFERNCE E201T FOR ADDITIONAL INFORMATION. > 10. GENERATOR ALARM PANEL. COORDINATE LOCATION OF (0 PANEL WITH G.C. PRIOR TO INSTALLATION. �~ O a 11. E.C. SHALL PROVIDE SWITCHING CONTROL FOR UPPER RECEPTACLE WITHIN FORMAL DINING 1031, AS NOTED. REFERENCE LIGHTING PLANS FOR SWITCHING LOCATION U) AND DESIGNATION INFORMATION. L U L N O W U co Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: FIRST FLOOR PLAN - AREA B - POWER J J U N A Sheet Number: `-' Cn U R a) E201 P '.SUMMIT SMITH DEVELOPMENT SP 0 SP 0 f� w z m ry 6 rn I 0 N w I �I U C� w U 0 .n c~� I N O O M E U 0 0 W 0 L a ti �t- d- M N O O N HV4 0 0 SP 0 HV2/C PR SP FF HV2/C HV1/C FR SP OF HV2/C HV4 0 ❑- VO 1 /C SP 0 r PS V02 A I E301 I PS I I I I I I I I I I I I I I I I SP 00 0 HV1/C SP I I I I ° I I VO 1 /C I I I I I 9 I E301 I I 0 V02/C SP ❑F SP 0 FF1uv1 it SP o[F:] HV3/C SP SP 00 VO 1 /C ni inuirr tSUJIIVtJ., OFFICE 1009 TRUE PLAN NORTH NORTH FIRST FLOOR PLAN -AREA B -TECHNOLOGY a HV1/C 0 V01 /C SP 0 SP 0 n.qP ❑F HV1/C SP 0 0 HV1/C SP 0 SP n u SP 0 HV2/C 0 ❑ SPEF DH SP 1CM DH DH 00 n U IVI DH SP SP a ❑F V02/C U SP 0 V01/C SP rl u Vol ❑F SP FS I F I , r„ SP FF TS L.LJU LJ HV1/C PS 0 [F SP HV2/C USP 0 HV2/C ❑F HV2/C �F SP 0 HV2/C OSP 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CID mmCvm CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 E7nnn n�� nn to f QX. z;GV-�G'+-G� I V Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 Wact nnnitnl drive - Rrnnkfialri WI 53045 Phone: 414.778.1700 / Fax: 414.778,23601 r-d@ringdu.coi RD Project Number: 218092.00 0 V02/C ❑F HV3/C [0co 0 CU ti [E]SP [E]SP V01/C O O � U 0 W L a� 0 y_ U) SP O ch_. SP ❑F HV3/C U i ❑F SP O W V02 PS CU _ OF a, VO 1 /C ❑SP pF Vo1/c Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: FIRST FLOOR PLAN - AREA B - �TECHNOLOGY J J (n U N L U Q Sheet Number: U a (6 rY E201 T Y O `;HEET NOTES - R LL1 z co O Iz 0 �I 0 NI w FI U w 0 U 0 2 c6 RE iR n LO Lp d- Cn C\1 M 0 CV __L J_ 1 I J_ 1 FH E302 I E302 I 4 I EM-15U FH NL7 NL-9 I INL7 I NL-21 I NL51�N� E302 I EM-15U NL8 N71 I NL8 NL-23 I I I I I I I o I I XF I I I I j� EM-14U I I FH rj 1=nn_1F1_► cu OD vEM-15U�• RB-16 — W5 W5 W5 W5 W5 T)T(T XG FLI RB-2 DC DC RB-2 DC RB-2 RB-2 RB-2 EM-14U 1.25 XYXF Ooo 41- nrnn -IGI I Or-ee AE11 DC DC ADC '", EM-14U DA DA - RD- I U - Clvl- I UU - Civl- I DU OEM-15U ORB -lb U EM-15U O DA O DA DA O O DA ORB-1b ORB-1b P18P18 EM-15U RB-3a RB-3a FQ 1 24 -15U RB 2 RB-1 RB-1 RB-1 P18 P18 P18 ORB-1 XF — — — — — DC DC DC EM-14U I— nDC nDC , nDC ORB-1b 0RB-1b ORB-1b n DA n DA n )1 IWOD 0 0 RB-1 b 0 RB b 0 RB-1 p - " RB-3c ., RB-3a DA r;", RB-16 P15 P15 P15 EM-15U P18 P18 P18 I I � RB 1 � RB 1 � RB 1 RB-5 RB-5 RB-5 DC ):� 0 DA DC DC DC E_ M-15U DC O DR_4n O RR-27 DB-3a 1 \U-Jl• 1 \✓-VG 1 \UV 'RB-1b ORB-Ib _DC O XG DA DA OEM-15U a c bt©1.26 )KEM-14U ORB-5 ORB-5 XGX 1.27©tt________ DA DA EM-1 DA NL5 I NL-39 I I O ORB-5 ORB-5 n ORB-4 4 I I I W5 RB-4 DA DA 1.28 E302 I RB-2 ORB-5 ORB-5 W5 NL7 NL-51 I I DA DA RB-201 NL7 NL-63 NL8 NL-65 - NL8 I D NL-53 ORB-5 ORB-5 0 I A DA FJ EM-15U EM-15U 1 I .�0 os B AAI 1 I NH-10 NH-10 P20 CPB-41 P20 CID ❑ NH-10 RB-4 NH-10 W5 I OS B W5 I RB-2 CP CP RB-2 I 1 O NH-10 �NH-10 OLi DA DA RB-4 �NH-,WE CFI RB-4 J ❑NH-10 1 OS] L OS NH-10 B I I I DA J B �- A 0 0 DA I NL7 NL-9 W5 EM-15U J EM-15 EM-15U NL7 NL-21 NL8 NL-11 I RB-2 JB Jg I NLS NL-23 IV ECM-15 EMS-�15 NH-100 � RB-2�I I � G11��1{f)FI I nnn _a M, pin o r/_U 1 I W 1 I RB-4 NH-10 -�- RB-4 I 1 E302 I I E302 P20 DA I DA DA RB-4 DA ORB-4 W5 RB-4 EM-15U EM-15U I I� 0 -2 1.38 RB-201 FJ I XF °I �o i ODA M-14UpA 1.39 XF I I EM-14UM-15U AA ❑ OS BEAA � EM-15U NH-10 NH-10 XF EM-14U oXF EM-14UX ®� ❑ J NL7 NL-33 I� O i 69 1.30 DA I NL7 NL-47 J -(�9 - NL8 NL-35 1.29 DA AA AA EM-15U I INL8 I NL-49 I EM-15U NH-10 NH-10 105 B OS oS B RW5 � I WE RB-7 DA OS B NH-10� DA ORB-6 - 9 O OS B -ram- ORB-6 I------ --.� I DA I 1 I AA NH-10 I 1 I NH-10 NL5 NL-57 4 I I E3027 I I E302 E302 P20 CID CID Li 1 RB 6 �NH-10 �NH-10 P20 1 IJ W5 RB-6 IRB-7 I V 0s B RB-7 +1 I O CP CP O DA �NH-10 �NH-10 DA EM-15U EM-15U II I----------J L---------J 4[Q 1.33 XG XG 1.34 © I c L — — — — — — — — J W5 ORBDA - ORB-8b ORB_ ODA ODA-14U O EM-14U +ODA- ODA- RB 8b 8b RB 8b RB 8b RB 8b RB 8b DA RB 8b RB 9c RB 9c DA ODA RB 8b0 A RB-7 P20 RB-8b P20 RB-8b P20 P20 EM-15U )8( EM-15U )P20 RB-8 0 RB-8 ORB-8 RB-8b OP20 RB-8 � RB-9 XF XF EEM-14U EM-14U RB-8 DA EMXF -14U DA DA DA DA DA DA DA DA OD P20 1aDA DA O ORB-8b DA RB-8b OEM-15U ORB-8b OEM-15U ORB-8b DAO OEM-15U ORB-8b 0RB-9c 0 ORB-16 RB-10 31 O EM-15U DA P20 RB-8b P20 EM-15U P20 EM-15U RB-8 RB-8 RB-8 P20 P20 P20 DA DA 0 RB-8 RB- 1.37 5 ORB-8 DA 0 RB-9 DA - - W5 � RB-8 W ORB-10 P20 RB 8b RB 8b DA DA DA DA DA DA DA DA DA RB-8b XG DA DA O W5 O ORB-8b ORB-8b W5 W5 ORB-8b�B-7 ORB-8b ORB-8bR -7 ORB-8b ORB-8b ORB-8b O W5-15UO EM-14U ORB-9c ORB-9c RB-79-------:9 RB-7 ------ ------ 9RB-7 y y ©1.32 r 7—FH DA O I IJEM-15U FH EM-15U VOID 0EM-15U I RB-16 XF O 1 EM-14U 0 I I I 0 I I I NL7 I N L-79 NL7 NL-67 I NL8 NL-81 NL5 NL-89 MARKETING NL8 NL-69 I m 4 1004 I 1 I 1 I E302 I FH E302 V E302 I I FH EM-15U u EM-15U I _ _ 0 _ _ L_____ __J L _F J 1 .1 TRUE PLAN NORTH NORTH FIRST FLOOR PLAN -AREA C -LIGHTING 1. REFER TO ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR EXACT LOCATION OF ALL ELECTRICAL DEVICES PRIOR TO COMMENCING INSTALLATION 2. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL POSITION OF THE CIRCUIT BREAKERS IN THE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. 3. REFERENCE SHEET E102 FOR PANELBOARD BOUNDARIES INDICATING PANELBOARDS SERVING THIS SPACE. 4. ALL 480Y/277V, NORMAL BRANCH CIRCUITS 'NH' FEEDING AREA SHOWN SHALL BE FED FROM "NH" PANELS, AS NOTED. 5. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NL' PANELS, AS NOTED. 6. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. 7. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. 8. "RB" AS IN "RB **" INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/1 MC UNLESS OTHERWISE NOTED. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 9. ALL EMERGENCY BATTERY UNIT (EBU) LIGHTS SHALL BE WIRED TO UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA WHERE EBU IS LOCATED. 77TSUMMIT SMITH REVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com C13 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17AM V1lee+ (`er,i+el Drive Rrnn4el d Inn F4f)Ar 1 v-rUU v VVOL vaN"UI v ivc- uiVVAII u, vv1UVU Phone: 414.778.1700 / Fax: 414.778,2360 / r-d@ringdu.coi RD Project Number: 218092.00 \`IIt II II III I, `� CONNE ''�. v'U\ 1 - •O �� No. 0033339 1 � O O � U O Q W O �i— C/) O N (3) U � L O N W ZD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: FIRST FLOOR PLAN — AREA C — LIGHTING U a) Q Sheet Number: C_ U .N CCU ry E202L c d 0 SHEET NOTES - A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. R w z M O ry �I 0 N O rn ri n M O M N rn O N NL1 NL-1 I NO NL-13 NL1 NL-25 NL2 NL-2 I NL2 NL-14 2 I NL2 NL-26 5 2 II NL3 NL-3 E302 I NL3 NL-15 E302 I NL3 NL-27 E302 NL4 NL-4 NL4 NL-1NL5 NL-17 I NL4 NL-29 INL5 NL-5 I I NL6 NL-6 INL6 NL-19 I II I I i II MVRV-E MVRV-E I MVRV-E MVRV-E I MVRV-F I ®L-6,8 ®L-10,12 I ®-18,20 ®L-22,24 I ®28,30 I I I I I 9 TR qPTR 9 TR OS-7 OS-7 OS-9 TDH PTR EM-3 OS-7 InI ; ECR v EM-2 -------�J`1MVRV-F I IVIL J4,36 I I& TR N L-67 I I 1 1 I I NL1 NL-33 N L2 N L-32 NL3 N L-35 [NL4 NL-37 5 I E302 I L------ -J NL1 I NL-51 I 5 NL2 I NL-52 NL3 NL-53 E�2/ NL4 I N L-55 I I I I I I MVRV-F N L-54, 56 TR ® TDH NL102 EM-9 ® MVRV-N OS-12,14 TR OS-25 ®MVRV-K OS-12,14 MEWH-5 NH-2,4 TDH EM-1 TR OS-9 ® MVRV-0 E�D TECR MVRV-0 OS-11,13 MVRV-0 EM-4 TDH ® OS-11,13 ® OS-15,17 MVRV-O EM-11® ® OS-15,17 TDH 1 TV TR ® I E306 4 TR nc 1v `v_I TV vv-1�1,, � OS-9 OS-111,,13 I ®OS-11,13 I NL 67 ---- TR I I r---------� WP NL1 2 NL1 NL-43 NO NL-55 NL2 NL-44 I COUNTRY I I NL2 NL-56 I NL ** nn q NI _dF IDS-19 KITCHEN TR =@I 11\11 nn _F7 1 NL4 NL-46 '"`' OS-9 I NL4 NL-58 NL5 NL-47 ® I MSS -A ®I ® NL5 NL-59rj OS-15,17 I I I NL6 NL-49 MVRV-D I I MVRV CFJ NL6 NL-61 NL-48,50 I ®� I I TECR I EM-12 I ®MVRV-A I MBS-A N WP 98 I I I OS-15,17 I OS-15,17 �I I ®s-A pp------� ® I I rm n n OS-15,17 NL-68 \fY NL-68 TDH GFCI ® EM-5 NL-96 I MVRV-A I 2 ® I OS-15,17 ® 2 ®VRV-A 1 ® E302 MVRV-D DD TR OS-15,17 MVRV-D E302 NH/1-2 (480Y/277V NORMAL) NL-52,54 1 OS-6 NL-686 I NL-64,66 NL/1-3 (208Y/120V NORMAL) DID EM/1-1 (208Y/120V EMERGENCY) GFI OS/1-1 (208Y/120V OPTIONAL STANDBY) GFI �OS-6 OS-19 TR _, NL-70 � s r� s a� ssss1-1_s NL1 NL-1 1�S-19 GFINL-TUR ' I NH/1-2 (480Y/277V NORMAL) NL3 NL-2 0 GFB I NL1 NL-13 I NL/1-4 (208Y/120V NORMAL) I ® NL3 NL-3 OS-2 I NL2 NL-14 EM/1-1 (208Y/120V EMERGENCY) GFI NL3 NL-15 OS/1-1 (208Y/120V OPTIONAL STANDBY) NL4 NL-4 I MVRV-A NLA03 I I I ® NL4 NL-16 NLI J I NLkil -5 I ,m�1 I OS-2'4 MVRV-C NL5 NL-17 NL6NL6 NL_7-7 MVRV-D NL-6,8 I I NL-18,20 NL6 NL-19 I WP ®os3 I I 3 N L-9 ?J I I L_ -- _J ® MBS-A OS 2,4 �® TECR Li I EM-6 I Ii OS-2,4 TR T . ® OS-21 � VRV-A I MVRV-D 2 2 I TR I NL-22,24 E302 MVRV-E® TR NL-97t TR OS-2A ® E302 I OS-21 MVRV GFI N L-10,12 I L� I� ® NL-92,94 TRW NL-97 TR TRD NL-91 MBS-A NL-97 NL-93,95 GFB --------- OS-2,4 -4 ® ® TRH---------� NL1 I NL-25 ® 18" TR OS-211 ' NL2 NL-26 0 NL-97 NL-99 ' Li NL3 NL-27 I MVRV-A ® =&@ I NL4 NL-28 OS-2,4 72" MBS-A NL5 NL-29 ® I ® NL-97 ® OS-2A NL6 NL-31 MVRV-E I MVRV-C nn 11n 121) I nn _AA as IVL-JV,JG I GFI J 1v- GFIWP NL-99 Y I N L-99 N -981 I 1 M\/R\/-A 1 1 OS-2,4 TRW I I Li ® NL-101 I TR I d2 1/ G\ I NL-101 OS-21 1 'ma' 2 E302 MVRV-D MVRV-C E302 NL-34.36 I TR I NL-48,50 5 OS-21 VTR NL-101 ® MBS-A o DD OS-2,4 L------- (5OS-27 L--------_� TR $) GFCI TR ® � TR $) OS-25 OS-23 TECR TR NL-106 OS-25 EM-8 -no -23 MVRV-K TR � 60" OS-12,14 = A OS-23 TR TR 96 N L-9EDT64 TFP2 TFP2 ® MVRV-K NL-100 NL-98 TR OS-12,14 A N L-96 TFP2 TFP2 @__ =@ MBS-A TR TR ® OS-12,14 TECR TR TR ® MBS-A NL-102 NL-102 ® EM-10 OS-25 ($OS-25 OS-12,14 MVRV-D ® NL-64,66 0 I NL-7R NL-68,6, 8 NL-80,82 I NL-88,90 I I I I NL1 NL-59 I NL1 NL-71 I 1 NL2 NL-60 I NL2 NL-72 NL3 NL-61 NL3 NL-73 NL4 NL-62 I NL4 NL-74 INL5 NL-63 NL5 NL-75 NL6 NL-65 2 I NL6 NL-77 2 I 5 I YE302 I E302 I E302 I - J LS -L._� TDH TR EM-13 6OS-23 MEWH-6 NH-6,8 TDH EM-7 2 TDH EM-16 TR OS-23 WP �N L-104 WP N L-104 B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL P%_.10 I ol"i OF THE CIRCUIT BREAKERS IIN' THE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. C. ALL208Y,120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' PANEL NUL-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL COMMON OR PUBLIC SPACES SHALL BE FED FROM 'NU PANEL NL/L-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS 'N L' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL AS NOTED. F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'N L' FEEDING AREA SHOWN SHALL BE FED FROM 'NU PANELS, AS NOTED. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. I. E.C. SHALL REFERENCE LOW VOLTAGE'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR ALL FINAL ROUGH -IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEMS SHALL INCLUDE: - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE -TELECOMMUNICATIONS, DATA NETWORK - EMERGENCY CALL SYSTEM - CABLE TELEVISION -AUDIOVISUAL, SOUND SYSTEM - WIRELESS NETWORK - EMERGENCY TWO WAY COMMUNICATION SYSTEM J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. SHALL PROVIDE 208Y/120V AND 480Y/277V NORMAL POWER, ESSENTIAL POWER AND NON -ESSENTIAL POWER, AS REQUIRED FOR A COMPLETE AND OPERATIONAL LOW VOLTAGE SOLUTION. K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENT POWER CIRCUITS. L. E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. COORDINATE EXACT LOCATION OF POWER CONNECTION WITH APPROVED FIRE PROTECTION SYSTEM CONTRACTOR. NCEYED NOTES - a 1. E.C. SHALL PROVIDE 4" X 4" JUNCTION BOX ABOVE ACT CEILIINIG FOR THE I"I STALLATIOIN' OF E1","ERGE"' I CALL REPEATER. E.C. SHALL HARDWIRE THE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH APPROVED LOW VOLTAGE VENDOR. 2. E.C. SHALL PROVIDE (1) 2 INCH CONDUIT FROM ELECTRICAL ROOM TO MEMORY CARE GATE FOR CONNECTION TO ELECTRIFIED HARDWARE. COORDINATE EXACT LOCATION OF CONDUIT TERMINATIONS AND ROUTING WITH APPROVED GATE LOCATION. 3. E.C. SHALL PROVIDE (1) 1 INCH CONDUIT FROM FLOOR BOX LOCATION TO NEAREST FULL HEIGHT WALL FOR ROUTING OF POWER CIRCUITS. 4. E.^i. SHALL PROVIDE 2-GAIVG RCIniESSCD IVIEDIA T7/PE OUTLET FOR POWER/TV/DATA CONNECTION. MANUFACTURER SHALL BE LEVITON 690W SERIES OR EQUAL. REFERENCE LOW VOLTAGE DOCUMENTS FOR ADDITIONAL INFORMATION. 5. E.C. SHALL PROVIDE (2) 120V-1P CIRCUITS WITHIN 2 INCH CONDUIT FROM ELEC ROOM 1090 INTO MC COURTYARD FOR WATER FEATURE CONNECTION. TIME CLOCK FOR LIGHTS AND FOUNTAIN SHALL BE LOCATED WITHIN ELEC ROOM 1090. COORDINATE EXACT FOUNTAIN LOCATION WITH LANDSCAPE ARCHITECT, COORDINATE FINAL INSTALLATION AND ELECTRICAL REQUIREMENTS WITH APPROVED WATER FEATURE MANUFACTURER. 6. E.C. SHALL PROVIDE (1) 120V-1P CIRCUIT WITHIN 2" CONDUIT FROM ELEC ROOM 1022 TO EXTERIOR FIREPIT. REFERENCE SHEET E201 P FOR ADDITIONAL INFORMATION. 7. E.C. SHALL PROVIDE (1) 2 INCH CONDUIT FROM EXTERIOR FIREPIT TO SWITCHING LOCATION WITHIN SUNROOM 1072. REFERENCE SHEET E201P FOR ADDITIONAL INFORMATION. 8. E.C. SHALL PROVIDE LEVITON 47617-REB, LOW PROFILE BOX WITH COVERPLATE 003-4767-LPF FOR INSTALLATION OF LOW VOTLAGE EMERGENCY CALL REPEATER DEVICE. REFERENCE TS SERIES DRAWINGS, SHEET TS511 FOR ADDITIONAI INFORMATION AND MOUNTING REQUIREMENTS. INSTALLATION OF RECESS BOX WITHIN FIRE RATED WALLS SHALL BE COORDINATED WITH GC PRIOR TO INSTALLATION. F_ A 241 N, Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-291 u" Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & w DUCHATEAU 17400 fNect (`nnitol Drive = RmnL inlrlV111 F10Ar, Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 0 N 1 No. 0033339 SOO O O U W 0 O �LLj O 4__ (J) ^0 W � C C'U N N L U i O 0) > W -0 C-0 U CU O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: FIRST FLOOR PLAN - AREA C - POWER J N U TRUE PLAN NORTH NORTH FIRST FLOOR PLAN -AREA C -POWER 1/8" =1'-01, Q Sheet Number: C_ U cu E202P a� 'SUMMIT SMITH ,LD)E VE L OPMENT 241 N_ Rrroadwav R W lei s PS 0 F - - I F - -L J- --L I r � I 3 I 3 I 6 I E302 I an � E302 I I I I I I I I I I I I I I I I I I I I I I I I 0 FS ° TS Sao HV1/C I I I I i I I I I I 6 I E302 1 I I I 6 I E302 I I D I I I I rFl I I I 1 I I PS HV3/C 00 HV3/C SP rel P u r0 ® V02 SP 00 ❑SP SP❑❑ HV2/C HV3/C SP 00 VO 1 /C 0 VO 1 /C [E]DH [F DH r.M DH --- �FCM 1 DH I BF SP F I HV1/C I I Fi I I I 3 I 1 E302 I ri I I I 1 ° SP I i L-------- -1 HV3 0 SP 1 D SP a HC OR 0 V01 /C a V01 /C u SP 0 SP 0 0 HC V01/C 0 VO 1 /C 0 V01 /C PS® HV1/C � I 0 SP I I I 3 I E302 Fi I 1 I 1 � I I I SP ' I I I I I I 3 I I E302 0 HV1/C Fi I I � SP DH F ° CM❑F 1 DH 0 DH CM ❑ DH ❑Sp I I I 1 F I 1 HV1/C 0 SP I 3 I E302 I I I I 1 SP 1 RR I I SP 0 0 0 a 0 0 SP SP SP HV1/C ST& V02 1005 PS I I I I I I I I I I I I I I I I MARKETING 1004 I I I 6 3 3 E302 1 II II E302 II YE302 L Lf-LS-L_S— Z_ S -L- —�1I I 21 TRUE PLAN NORTH NORTH FIRST FLOOR PLAN - AREA C - TECHNOLOGY 118" = V-0" HV3/C 0 SP PS 0 0 Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 0 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 Qlni� Q D�UCHCx ATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.17001 Fax: 414.778.23601 r-d@ringdu.coi RD Project Number: 218092.00 ��•��\F CONNc- �'�•. O T ^d �. No. 0033339 ` -Z-1- CO O O � U O L U) LOP W 0 (3) CU N U L 0 LU U � � CV L Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: FIRST FLOOR PLAN - AREA C - TECHNOLOGY L U Q Sheet Number: C- U Cn CU Y C d `SHEET NOTES - 1„ REFER TO ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR EXACT LOCATION OF ALL ELECTRICAL DEVICES PRIOR TO COMMENCING INSTALLATION `w �' J'1V111 H DEVELOPMENT R LU z m O ry n �I 0 CVI w U O LL U) c6 C_ U 0` -0 c6 CVI 00 c Cu U 0 0 w 0 U) E n co Cn CV CD CV I 4 I 2„ CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL PvviTivN OF THE CIRCUIT RRE,AW11M TUC: PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. 3„ REFERENCE SHEET E102 FOR PANELBOARD BOUNDARIES INDICATING PANELBOARDS SERVING THIS SPACE. 4.. ALL 480Y/277V, NORMAL BRANCH CIRCUITS 'NH' FEEDING AREA SHOWN SHALL BE FED FROM "NH" PANELS, AS NOTED. 5,. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NL' PANELS, AS NOTED. 6„ ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. T. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. 8„ "RC" AS IN "RC-**" INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/2AL UNLESS OTHERWISE NOTED. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 9„ ALL EMERGENCY BATTERY UNIT (EBU) LIGHTS SHALL BE WIRED TO UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA WHERE EBU IS LOCATED. AA---- --- — ------ -- �NH-171 E301 I I E301 I E301 I-"' ��� F FH FH IFI NL6INL-I o I A o I EM-18U Fv�EM-18U 141 IB NL6 NL-7 NL6 NL-15 p I 1 EM-18UNL6 NL-25 E301 4 m I m I NL6 NL-15 E301 � I o5 AA I E301 I E301 I � � 0 NH-17 C I I I I NL6 NL 25 I NL6 NL-33 I E300 E300 I I I I I I I I L, I I I I 9 0 1 I I I FH I I FH I I I ]FC DA I I I FH EM-18U EM-18U FH EM-18U I LEM-18U I I XF EM-18U I I L---------� NH-17 --------�-- ----- I I NL6 NL-35 EM-16U I I I W5� W5 W5� I I I XF 1 NL6 N L-4i5 yEM-16U RC-7 DA DA --1P20 „ P20 ,. �^RC-9 EM-1 U�"� 1 ' E -16U I �� I FI2.01 ,. WP20 1 "-, '—'---------------L--------- EM-18U RC-6 D'A RC W5 — �"�RC-8 pA SRC-8 pq �"� RC-8 Dq SRC-8 DA P20 W5 W5 O RC-7 DA � �W5--------------- P20 � � XG 2.02 EM-1 U RC-7 XG EM-18U RC-8 RC-8 EM-18U RC-8 RC-9 RC-9 EM-16U EM-18U P20 EM-16U DA RC-7 P20 pq DA DA P20 DA RC-6 BEM-16U DA P20 DA DA P20 DA DA T�T O RC-6 OT O O RC-6 O DA RC-6 O RC-6 OEM-18U O OEM-18U O O OEM-18U RC-80 RC-8 O RC-8 RC-9 DA RC-6 RC-6 XFT� B B XF EM-18U RC-8 RC-8 W5 W5 RC-6 EM-18U W5 W5 EM-16U DA DA OS DS DA TEM-16U W5 ���-CCW5 W5 P20 W5 I � RC-7 — � RC-7 — — — — — — — 9 RC-7 — — — — —)1RC-7 — — — O RC-8 O RC-8 O — — —)I RC-9 — — — — — — — — :i RC-9 T— — RC-9 — RC-8 RC-9 �-- -- —� � � AA NH-17 WE H-17� -- — � -- I — NL-5'] I I I I I CID CID NH-17= 0 0DA I I ( I NH-17 NH-17 DA EM-18U pS B EM-18U ' ❑ ❑ B❑ J d�XS / ju� CS I I �- DA DA CID CID CID AA AA 1 I I I I BOS FC &9 ORC-8 ORC-8 NH-17 NH-17 NH-17 NH-17 NH-17 1 E300 I I I I NH-N� -17 F F 1 I NL6 NL-71 I NL6 NL-63 I E 00 1 I NL6 NL-57 I NL6 NL-70 7 I 4 NL6 NL-77 I AA OS B DM-18U DA 2.03 EM-18U EM-18U I 4 I I I ---------.� 4 YE301 E301 NH-17 RC-8U DA NL6 NL-81 I E301 I 1---------� E301 I I I -� O M O P20� O M- 8U I E301 E301 I I I I RC-8 XF)K FH FH I I I I---------—�-----------y-- --- ------ RC-8 � EM-16U EM-18U EM-18U L—-------�— — I — —� '-, XG� r -- --- (— EM-16U 1----�----J 4 I p I I E301 1 RC-10 I 1 I E301 I I I P20 I I RC-10 I w5 1 RCA 1 RC-11 AI NL6 NL-7 1 NL6 NL-33 I EM-18U I I I I DA 1 1 oC-10 I 4 ( W5�1 NL6 NL-15 I E301 1 RC-11 I I �20 I I I RC-10 I FJ DA III EEM-18U I 1 NL6 NL-45 I RC-110 I E301 I I I I DA 4 O RC-10 I E301 4 I I 30I P20 E1 I I RC-10 1W5o I I RC-11 RG11 I NL6 NL-25 1 1 NL6 NL-53 I DM-118U L---------J TRUE PLAN NORTH NORTH 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD VVIVj I RUl^i I IV V jEf�CVI^iEJ 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924 9 i u^ Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778,23601 r-d@ringdu.cor RD Project Number: 218092.00 A No. 0033339 4t// r co O O � U L O L LJU o UUI— O U) CC5 cu CD U 2) L N OLU Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA A - LIGHTING C_ U Sheet Number: Cn CU N c a. 0 SECOND FLOOR PLAN - AREA A - LIGHTING 118" =1'-01, KEYED NOTES - a SHEET NOTES - A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. PPIWSUMMIT SMITH DEVELOPMENT w z m O IZ ,nJ' IY of 0 NI LLI �I U C� w ca U 0 2 M 17 CV rn 0 00 c a� U 0 w A, n N M N rn 0 N NH/2-1 (480Y/277V NORMAL) NL/2-1 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL S T ANDBY) NL1 NL-19 NL1 NL-10 NL2 NL-20 E 01 I NL2 NL-11 5 NL3 NL-21 I NL3 NL-12 E301 NL4 NL-22 NL4 NL-13 NL5 I NL-23 I NL5 NL-14 NL7 NL-27 NL7 NL-17 NL8 I NL-28 I i I I I ! I _® MVRV I I NL-24,26 MVRV-G I NL-16,18 L- --- MBS B TR -------1-----------� E.C. SHALL PROVIDE 4" X 4" JUNCTION BOX ABOVE ACT CEILING FOR THE INSTALLATION OF EMERGENCY CALL REPEATER. E.C. SHALL HARDWIRE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE FINAL INSTALLATION REQUIREMTNS WITH APPROVED LOW VOLTAGE VENDOR. INH/2-1 (480Y/277V NORMAL) NU2-2 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) IOS/2-2 (2U8Y/1ZUV OF II IUNAL S IANUBY) NL1 NL-1 TR TRW NL2 NL-2 5 ILL-95 AGFB NL3 NL-3 E301 I `F- INL-an �I E301 E301 NL4 NL-4 TRD NL1 NL-1 I NL1 NL-10 NL5 NL-5 NL-88 90 NL2 NL-2 NL2 NL-11 r 2 I 2 B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL POSITION OF THE CIRCUIT BREAKERS IN THE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. C. ALL208Y,120V, NORMAL BRANCH CIRCUITS'NU FEEDING LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' PANEL NUL-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS IN L' FEEDING LOWER LEVEL COIV MON VR PUBLIC'PAC ES SHALL BE FED FROM 'NU PANEL NL/L-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL AS NOTED. F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'N L' FEEDING AREA SHOWN SHALL BE FED FROM 'NU PANELS, AS NOTED. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAL AC .qHC71A/N SHAI I RF FFn FRnM ,nS, PANELS, AS NOTED. �. ,_ � �• ' ' •• •__ __ . __ ..._... __ H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. E.C. SHALL REFERENCE LOW VOLTAGE'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR ALL FINAL ROUGH -IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEMS SHALL INCLUDE: - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE -TELECOMMUNICATIONS, DATA NETWORK - EMERGENCY CALL SYSTEM - CABLE TELEVISION -AUDIOVISUAL, SOUND SYSTEM -WIRELESS NETWORK - EMERGENCY TWO WAY COMMUNICATION SYSTEM J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. SHALL PROVIDE 208Y/120V AND 480Y/277V NORMAL POWER, ESSENTIAL POWER AND NON -ESSENTIAL POWER, AS REQUIRED FOR A COMPLETE AND OPERATIONAL LOW VOLTAGE SOLUTION. K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENT POWER CIRCUITS. L. E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. COORDINATE EXACT LOCATION OF POWER CONNECTION WITH H APPROVED FIRE PRO T EC T IUN S Y S T EIVI CONTRACTOR. - - - - - - - NL7 NL-9 ® GFB I NL3 NL-3 I NL3 NL-12 I E301 E301I-TRD NL-93 NL4 NL-4 NL4 NL-13 NL2 NL-20 I NL1 NL-28 NL5 NL-5 NL5 NL-14 + NL2 NL-29 I I 2 NL-92,94 I NL6 NL-9 I NL6 NL-17 r NL3 NL-21 I NL3 NL-30 E300 TR I + NL4 NL-22 I NL4 NL-31 NL-95 I r NL5 NL-23 NL5 NL-32 1 I I NL7 NL-27 I NL7 I NL-35 I I nnvav_r_ d1 22 I MVRV-G i MVRV-G + I MII KI NL 6,8 v I) E303 NL-6,8 NL-16,18 I NL2 NL-38 -----------L-J----------------� ® I ® I ® NL3 NL-39 ® MVRV-A ® I MVRV G I MVRV-H I I MVRV-G NL4 NL-40 TR NL-85,87 TR NL-24,36 NL5 NL-43 OS-2 OS-4 MVRV-A MBS-B L - - - - - - - - NL-44,46 NL7 NL-47 NL-85,87 OS-2 NL ® MVRV-A ®MBS-A 2-1 �®TECR TR NL-85,87 EM-6 OS-2 NL-85,87 I I 2 I E300 I I I n 1 nIi _ v NL2 NL-30 NL3 NL-31 NL4 NL-32 NL5 NL-33 MVRV-H NL7 N L-37 N L-34, 36 - NL1 NL-43 - NL2 N L-44 IVIVRV-H ® NL-85,87 NL-89,91 TECR TECR NL TR_ ® NBS-B �® EM-TECR TR MVRV-A � ® TECR EM-2-2 OS 4 85,87 TR - - - - - NO NL-48 - - MBS-A DD DID MVRV-A OS-4 NL-85,87 OS-4 NL2 NL-49 Nil -Q7 Nil -Q7 ® Nil -PI; $17 vrI A `W I IVIL3 IVIL 5V 'o• NL-85,87 I NL3 NL-45 NL-48,50-------------------------------� ,, NL1 1r---------------------------� ® NL4 NL-51 NL5 NL-47 ® ® ® NL-85,87 L-101 I NL-54, 6 NL5 NL-52 NL5 NL-47 ® pp cU� NL7 NL 55 I NL7 NL-51 e MVRV-G I MVRV-H I MVRV-E I OS-6 TUR I V V-F I ®VRV-F V V-G NL-58,60 I NL-66.68 I NL-76,78 I GFB I NL-80,82 I NL-72.74 I NL-62,64 OS-8 TDH GFI GFI I I I I OS-12 NL-97 NL-99 OS-6 NL-99 I I NL1 NL-66 NO NL-57 I 2 ( NL1 NL-52 I I $ ® I I NL2 N L-67 I NL2 N L-58 NL1 NL-61 NL1 NL-71 E303 2 E300 ( NL2 NL-53 I NL2 NL-62 I NL2 NL-72 I NL1 NL-75 I NL3 NL-68 I NL3 NL-59 NL3 NL-54 - - - - 9 NL2 NL-76 NL5 NL-70 NL5 NL-61 E300 NL3 N L-63 NL3 N L-73 NL4 NL-55 I NL4 NL-64 I NL4 NL-74 TR I NL3 NL-77 I NL5 NL-70 I NL5 NL-6 L - - - - - - - - NL5 NL-56 NL5 NL-65 NL5 NL-75 OS-10 NL4 NL-78 NL7 NL-73 I NL7 NL-65 - - NL7 NL-59 5 NL7 NL-69 $ NL7 NL-79 5 NL-38 NL5 NL-79 5 I 2 2 I L8 E301 E301 E301 I I I NL7 NL-83 E301 I E301 I I NH/2-1 (480Y/277V NORMAL) E301 I NNL-70 1 I I NL/2-2 (208Y/120V NORMAL) ---------I---J------------1---I-- ---- �_--------1---------� L-------J.._-_l_-..L-�- EM%2-2(208Y/120VEMERGENCY) _ _ _ _ _ OS/2-2 (208Y/120V OPTIONAL STANDBY) NH/2-1 (480Y/277V NORMAL) I I I I N NL/2-6 (208Y/120V NORMAL) H/2-1 (480Y/277V NORMAL) EM/2-2 (208Y/120V EMERGENCY) I 5 I 2 NL/2-6 (208Y/120V NORMAL) OS/2-2 (208Y/120V OPTIONAL STANDBY) E301 EM/2-2 (208Y/120V EMERGENCY) E301 I ® I I OS/2-2 (208Y/120V OPTIONAL STANDBY) MVRV-A NL-58,60 I NL1 NL-1 NL1 NL-28 I I NL2 NL-2 ® ® ® NL2 NL-29 ® I NL3 NL-3 (K31) (K55) (E11) I NL3 NL-30 MVRV-G ®V V,,p�,_E NL4 NL-4 EF EF EF NL4 NL-31 NL-34,36 NL-6,8 NL5 NL-5 NH/1-1 NU1-K NU1K I NL5 NL-32 I NL7 NL-9 37,39,41 45 41 I NL7 NL-35 TR��----- OS-10 NL1 NL-10 -� I I I I NL2 NL-11 NL3 NL-12 ® NL4 NL-13 5 I I MVRV-E NL5 I NL-14 E301 I ® NL-16,18 NL7 NL-17 NLB-58 60 I I I FJ NL1 NL-37 NL2 NL-38 ® I 2 NL3 NL-39 MVRV-G fi I E301 NL4 N L-40 N L -44 46 I'I N L NL5 N L-43 2_g NL7 NL-47 TECR EM-1 I I 0 s I 5 I TR I E301 E301 I OS-10 I I I I NL1 I NL-19 m nn nil on IVLG IYL GV NL1 NL-48 I I MVRV-F NL3 NL-21 NL2 NL-49 ® MVRV NL4 NL-22 NL3 NL-50 MVRV-G I I NL5 NL-23 NL4 NL-51 NL-54,56 I I NL7 NL-27 NL5 NL-52 TRUE PLAN NORTH NORTH 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond WU L IU, VVJ 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 I.71 ai DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778,1700 / Fax: 414,778,23601 r-d@ringdu.col RD Project Number: 218092.00 L� �V O O � U O L_ C/) III r, W O C C- N L UL i_ CD O � W co a _ ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA A - POWER U N U Q Sheet Number: C_ U (C6 E203P Y c 0 SECOND FLOOR - AREA A - POWER 1/8" =1'-0" KEYED NOTES - a SHEET NOTES - A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. PPRqS'UMMIT SMITH DEVELOPMENT 241 N- Broadwav NH/2-1 (480Y/277V NORMAL) NL/2-1 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) NH/2-1 (480Y/277V NORMAL) NL/2-2 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) IOS/2-2 (208Y/120V OPTIONAL STANDBY) E.C. SHALL PROVIDE 4" X 4" JUNCTION BOX ABOVE ACT CEILING FOR THE INSTALLATION OF EMERGENCY CALL REPEATER. E.C. SHALL HARDWIRE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE FINAL l"ISTALLATiON REQUIRE"VITI".IS VVII IJADDDvVED LOVv1 VOLTAGE VENDOR. �__________,I ^___,__s____T__o_�_�__� NL1 NL-1 'TR TRW ( j' -�--- - I NL2 NL-2 5 I NL-95 GFB I 2 I 2 I - -J------r----i _ _ � NL3 NL-3 E301 NL-86 L NL1 NL-19 8 NL1 NL-10 s NL4 NL-4 I TRD ®I E301 NL1 NL-1 I NL1 NL-10 E301 NL2 Nil 20 E301 I NL2 NL 11 5 4 NL5 NL-5 NL-88,90 ® NL2 NL-2 NL2 NL-11 + 2 I 2 B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL POSITIOIm OF THE CIRCUI? BREAKERS IIVI THE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. C. ALL208Y,120V, NORMAL BRANCH CIRCUITS'NU FEEDING LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' PANEL NLJL-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL COMMON OR PUBLIC SPACES SHALL BE FED FROM 'NU PANEL NL/L-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL AS NOTED. F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NL' PANELS, AS NOTED. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM `OS' PANELS, AS NOTED. H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. I. E.C. SHALL REFERENCE LOW VOLTAGE'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR ALL FINAL ROUGH -IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEMS SHALL INCLUDE: - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE - I ELCCOIVIIVIUIVII.A I IVNS, UA IA NE 11 VVUMN - EMERGENCY CALL SYSTEM - CABLE TELEVISION -AUDIOVISUAL, SOUND SYSTEM - WIRELESS NETWORK - EMERGENCY TWO WAY COMMUNICATION SYSTEM J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE 'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. SHALL PROVIDE 208Y/120V AND 480Y/277V NORMAL POWER, F_SSFNTIAI POIA/FR ANn NON-F_SSF_NTIAI POWER AS REQUIRED FOR A COMPLETE AND OPERATIONAL LOW VOLTAGE SOLUTION. K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENT POWER CIRCUITS. L. E.C. SHALL PROVIDE (1) 20A-lP, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. COORDINATE EXACT LOCATION OF POWER CONNECTION WITH APPROVED FIRE PROTECTION SYSTEM CONTRACTOR. r - - - - - - - - - - - 1 _ NL7 NL-9 TRW NL3 NL-3 I NL3 NL-12 NL3 NL-21 I NL3 NL-12 E301 ` ® GFB E301 E301 I r I I NL4 NL-22 NL4 NL-13 9 I NL-93 I NL4 NL-4 I NL4 NL-13 � NL1 NL-19 I NL1 NL-28 I I NL4 NL-23 NL4 NL-14 ® TRD NL5 NL-5 NL5 NL-14 NL2 NL-20 NL2 NL-29 2 2 I I + I E300 I NL7 NL-27 NL7 NL-17 � I NL-92,94 I NL6 NL-9 I NL6 NL-17 r NL3 NL-21 I I NL3 NL-30 I E300 I I d 1 .I. To 1 i NL4 NL-22 1 nil n nil _11 NI I ' NL5 NL-23 L-95 I 1\L 1 _ N L5 N L-32 I I I I NL7 NL-27 I NL7 INL-35 L I I I I I I ' n._11_1T\II=901 II II ® II ®nn/off _II 12 II ® MVRV--G- I®MVRV--G- + I I r-� IVIVINV-v N.L-•6-8 NL-1618 1 NL"IVL-b/ 0 NL-6,8 E303 NL2 NL-38 NL3 NL-3MVRV-I L J+ ® I I I NL3 NL-39 I NL4 NL-32 I NL-24,26 I MVRV-G I qP MVRV-A $1 I MVRV-G MVRV-H I ® NL4 NL-40 NL5 NL-33 MVRV-H I NL-16,18 TR I ® ® NL-24,26 I I MVRV-G nli 7 n11.17 NL-34.3E I NL-85,87 TR NL-24,36 NL5 NL-43 Oc_� ne_n IVIVF\V MBS-B L I NL-44,46 L�4 __7NL ___ ___-+ �� I ��-T mvr�V-r1 `__ _.� NL/ NL-4/ m_ MBS-B trr TR � ® NL-85,87 NL-89,91 N -- _ - - -- - - - - - � NL-85,87 OS-2 MBS-A L TR ® MBS-B TECR TR ® MVRV-A ® TECR TECR OS-4 NL-85,87 NL1 NL-43 2-1 �� EM-6 OS-2 NL-85,87 NL-85,87 ® EM-2 TR MVRV-A ® EM-4 2-2 TR s NL1 NL-48 DID DID ® MVRV-A ^^ OS-4 NL-85,87® I NL2 NL-49 NL2 NL-44 nmiov_u m MBS-AOS-4 �� I V I V I\ V -1 I II VI L-97 II VI L-97 1 VI L-85, V I 1 I NL3 NL-45 NL-48,50--------------------------- 'o' fvL-85,87 vrl _ w' _----- ------ ---- � NL3 NL-�U NL4 NL-46 T _ _ ® MVRV-A NL-101 NL-1Q1r T T ® MVRV-F NL4 NL-51 �� NL5 NL-47 NL-85,87 + NL-54,56 NL5 NL-52 NL7 NL-51 ® I ® i ® I � DD I ® I ® I ® 1 NL7 NL-55 MVRV-G MVRV-H MVRV-E I OS-6 TUR MVRV-F MVRV-F I MVRV-G + NL-58,60 I NL-66.68 I NL-76.78 I GFB Ni -8n 82 nil _70 7A NI -R9 Fa 1 - - - - -. - I ---.-- i .T .1 . • I OS-8 I TDH GFI GFI ® OS-12 NL-97 NL-99 OS-6 NL-99 I I NL1 NL-66 I NL1 NL-57 �� NL1 NL-52 I NI 11-I NI _R1� I NL1 I N \ $us� �_ �_ _ I I NL2 NL-67 I NL2 NL-58 E300 NL2 NL-53 I NL2 NL-62 I NL2 NL-72 t`SJ I NL1 NL-75 I NL3 NL-68 I NL3 NL-59 NL3 NL-54 NL3 NL-63 NL3 NL-73 NL2 NL-76 NL4 NL-69 NL4 NL-60 E300 I I NL4 NL-55 I NL4 NL-64 I NL4 NL-74 - - - TR � I NL3 NL-77 I NL5 NL-70 I NL5 NL-61 NL5 NL-56 NL5 NL-65 NL5 NL-75 OS-10 NL4 NL-78 NL7 NL-73 I NL7 NL-65 l N L7 N L-59 I I �� I / 5\ I N L-38 I N L5 N L-79 / 5\ I �� / 9 Nil � nil _ag � INI 7 I NI.7g L E301 I I I I NL7 E301 I E301 E301 I NL8 NL-70 E301 NL-83 I E301 I NNH/2-1 (480Y/277V NORMAL) L 2-2 (2081%120V NORMAL) L__•________.�-----____-- -� __-- ____ _�---____-- L______-- -�- _ I -� EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) NH/2-1 (480Y/277V NORMAL) NL/2-6 (208Y/120V NORMAL) 1 1 0 NH/2-1 (480Y/277V NORMAL) EM/2-2 (208Y/120V EMERGENCY) I 5 I 2 NL/2-6 (208Y/120V NORMAL) OS/2-2 (208Y/120V OPTIONAL STANDBY) E301 EM/2-2 (208Y/120V EMERGENCY)E301 I I I OS/2-2 (208'(/120V OPTIONAL STANDBY) � 1 I ivwRv-A I NL-58,60 NL1 NL-1 I ® ® ® NL1 NL-28 NL2 NL-2 I NL2 NL-29 ® I I ® I (K31) (K55) (E11) I NL3 NL-30 MVRV-G I MVRV-E NL4 NL-4 EF EF EF NL4 NL-31 NL-34,36 I NL5 NL-5 NH/1-1 NL/1-K NL/1K I I I NL-6,8 NL5 NL-32 NL7 FNL-9 37,39,41 45 41 I NL7 N L-35 I TR �NL1 NL-10 - sssssssssa II OS-10 I NL2 NL-11 NL3 NL-12 5 I ® NL4 NL-13 NL5 NL-14 E301 I ® I MVRV-E NL7 NL-17 NL-16,18 I NLB-5 60 I I � NL1 NL-37 I I NL2 NL-38 ® I 2 NL3 N L-39 MVRV-G NL4 NL-40 NL E301 NL-44,46 NL5 NL-43 2_6 NL7 NL-47 TECR EEM-1 ED* 0 5 I 5 I TR I E301 E301 I OS-10 I I I I E1 NL-19 ® NL2 NL-20 NL1 NL-48 I I MVRV-F NL3 NL-21 NL2 NL-49 ® I NL-24,26 NL4 NL-22 NL3 NL-50 MVRV-G I NL5 NL-23 NL4 NL-51 NL-54,56 I I NL7 NL-27 NL5 NL-52 NL7 INL-55 TRUE PLAN NORTH NORTH Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD 93Rq/ G 7 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 Qlnl� Q 111IV1.1 CX DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 \�.� aF G0 N NFC".,�. ,`�,,,��PNER yy,% G co I ' No. 0033339 � r ICU d- O O U L. O L U) -+� W O V A U) CU cu i L U O L N O W co U O a ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA A - POWER J _I U QSheet Number: U co N E203P d 0 s SECOND FLOOR - AREA A - POWER 1/8" =1'-01, KEYED NOTES - a 1. REFERENCE FINAL FIRE PROTECTION DRAWINGS FOR COORDINATION OF TAMPER AND FLOW SWITCH LOCATIONS AND INSTALLATION REQUIREMENTS. =SUMMIT SMITH I)E VEL OPMENT f� LLJ z co O ry rn 0 NI LU U C� L11 aD M C- U 0 U 0- M M N rn 0 N 0 PS I I 3 I E300 i I 1 I I I I e I I I e I I M I I I 1 3 I I I E300 I g 6 I 12 I 6 I --_-----------� E301 I I E301 I E301 E301 I I 9 I 6 I E301 I E301 I I j I I I I I I I I I I SID 00 0 s 00 HV1/C SP HV1/C 0 HV2/C VO 1 /C ❑F 0 SP S 0SID }TOP OF 0 HC J SHAFT 0 CM IF] M M EV2-2 0 CM EV2-1[0 EV2-3 HC [OCM [E]CM EV2-1EV2-4 HC 0 0 V01 /C 0 SP � I e (E30101 I E301 e I 3 I 3 I E301 I E301 I I I 0 a HV1/C SP CARE PARTNER 0051 0 V02/C 00 TS FS 10 PS 0 HV1/C I I I 6 I E301 I I I I I I I I I I I I I I I 16 I E301 I I I I I I I I I I I I I �V01/C —� I I 6 I I E301 I I I I � I HV1/C OF HV1/C SI DHD CM/DH ❑F 0 CM/DH ° °DH L-- V01/C_--OSP .J TRUE PLAN NORTH NORTH VO 1 /C SP 0 0 V01 /C 0 I I 3 E300 I LI I I I I I I I I I I I I I I I I I I I I I I I I I I I I j 3 1 I I I I E300 I E301 I 3 e 3----------_J I I E301 I E301 I I I I 3 E301 HV1/C o e SP I I I I I I I I e I I I I I 0 I � SP I 3 I E301 I I I I 0 I I HV1/C e I e 6 I E301 0 I I SP I e I I I SECOND FLOOR - AREA A - TECHNOLOGY 1/8" = V-0" HV1/C 0 0 SP ®S ❑ SP❑❑ SP HV1/C 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & :L- � UUUNA I LAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.coi RD Project Number: 218092.00 tG0NN� ��,•�pPHER No.0033339 Z--f-l� O � U L O cn 2) W to 0 00 U OA W U 0 C-0 r O CIO � a = ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA A - TECHNOLOGY C U Q Sheet Number: U co E203T C6 N 0- 0 SHEET NOTES - R w z m O 6 ry i rn 0 N L.u� t—I U UJ U 0 ca U DC P10 RC-1z RC-2 DC 0 O RC-1 y DC EM-20U \ DC ORC-1z DC ORC-1z P10 RC - DC 0 ORC-1z DC EM-20U DC O RC-1z DB DB EM-20U DB EM-20U DB O P10 ORC-1y O P10 ORC-1y ff ff ODB ODB ODB ODB RC-1y RC-1y RC-1y RC-1y DB DB RC-1y DB RC-1y DB O P10 ORC-1y 0 P10 ORC-1y RC-3 RC-3 DB DB DB DB OEM-20U ORC-1y OEM-20U ORC-1y DB DB E)LW DC DC OEM P10 5n ORC-1y RA-1OEM-20U P10 OEM-20U RC-3 RC-4 DC DC 0 RC-1 x 0 RC-1 x ODB O DB DC/ DC RC-1y RC-1y 0RC-1x ORC-1x DB DC DC O-1Y P10 ORC-1 DB ORC-1x P10 0RC-1x Y RC-3 RC-4 DC DC O RC-1 x 0 RC-1 x DB DB D DC OEM-20U ORC-1y LW OEM-20U OEM-20U RA-15n F-7AA DA DA NH-17 P20 NH-17bP20 NH-17b n NH-17a0 BNH-17,aO B -�- OS M DA NH-17b F_7qq O O NH-17 DA LLJk ui\ NH-17b X XG © 2.23 J EM-106U DA P20 A DA P20O RC-10 O RC-10 0 DM-20U O LO 0 CN RC-10 RC-10 XFDA W EEM-20U EM-16U RC-10 EM-20U O AA no n NH-17 RC-10 u OS B O DA EM-20U b 0 �c DA RC-10 XG EM-16U O nn EM-20U CA ❑ NH-17 OS B LD NH-17b DA DA DA DA DA ONH-17 ONH-17 ONH-17 ONH-17 ONH-17 DA DA NH-17 OS B NH-17 O O DA NH-17 ILD NH-17b OS B DA OS B DA NH-1170t ONH-17 I DA DA ONH-17c ONH-17c OS B DA DA ONH-17c ONH-17c LID NH-17a W4 O DA u U U W�4 TA T11 NH-17c NH-17cNH-17d DA NH-17c DA NH RC-12 TA TA O O ONH-17c 0di--- C 619 --------� XFX nn DA LilNH-17c NH-17c DA Enn-161 II 0RC-12 0DA DA TA � NH-17c NH-17c 4TA op, E M-16U DA EM-20U I NL6 NL-75 O O o TA T1 DA NH-17c ODA DA ® NH-17d NH-17c NH-17 RC-12 O DAO O DA DA NH-17c - 9 ONH-17c ONH-17c B 0S O z�l -17 W5 TA TA T1 NH-17cNH-17d TA � �n/4 NH-17c FC FC NH-17 NH-17 t4, .P XS DA WE RC-131 4 DA NH-17c 4NH-17 DA I E301 0NH-17r. 0 DA DA DA ONH-17a ONH-17a ONH-17a OSB0 P20 P20 DA O NH-17b O NH-17b ONH-17a DA DA OS B NH-17a NH-17a " RC-12I I O DA O DA EM- OU P20 RC-121 DA ARC-12 DA I NL6 NL-67 O RC-12 O RC-121 I I I 0 DA RC-13 ONH-17a 0I b� DA 4 EM-20U I E301 DA I 0NH-17a FH F--- ---� P20 L-----------� RC-12 — — EM-20U FH I 7 EM-20U E301 �NH-17 �NH-17 �NH-17 IVJI—IAAF nn �' �� I OS B I J R I C H P` T B H N H-17 O RC-12 O RC-16 0 RC-16 O RC-14 DA O DA RC-14 NL6 NL-15 I CN !1 t 02.04 XG P20 E300 I I I ❑ N H-I 17 ❑ RC-14 CNEM-16U N H-17 DA DA DA DA WE � O RC-16 O RC-16 0 EM-20U O RC-16 0 DA 0 DA NH-17 FC RC-14 RC-14 0 DA NH-17 WB DA 2.05 0 FH NH-17 OS 4RC-17 �` I IJ 0RC-15z z EM-20U FH OS t B DA DA EM-20U B OEM-20U 0 EM-20U DA DA NL6 NL-7 I DA I I RC 0RC-15z 0RC-15z ---- 1 RC16 I XF���$M-20U L-------�W5 J DA EM-16U RC-19 C_ P12 0 RC-15z — — — — — — — — -- —� TAT 0 DA O DA P20 0 DA 0 DA ):�RC-16 P20 0 O DA RC B RC-5 RC-5 R IflWB 17 O DA W5 P20 XG RC-18 OEM-20U RC-18 RC-18 EM-20U DA XG RC-16 P12 RC-16 DA DA RC-1 RC-18 EM-16U W5 L 2.07 EM-20U EM-16U 33 P12 RC-5 0 RC-15z 0 RC-15z RC-19 ❑ ---- DA RC-5 NL6 NL-25 I RC- 0RC-16 DA AANH-17 I I DA EM-20U O 0 EM-20U 0 b 2.06 I Il B WB OS B I I O WE FC RC-17 RCD160 0 0 O ❑ AA NH-17 XF DA PZO DA DA NH-17 I I DA DA DA DA DA EM-16U RC-16 EM-20U — 4 — — O RC-16 0 RC-16 OEM-20U 0 RC-16 — — RC-16 — I � I I NL6 N L-34 AA I E300 NH-17 I I W5 WB WB w5 I , I — — — RC-17 RC-17 RC=13' RC-13 J I----------� I 7 AAF BSD r--- I AAF E301 I L_ — NH-17 NH_17� --- --- I NL6 N L-49 I NL6 N L-57 I 4 I 4 I E300 E300 I I I L------------------------------J 1. REFER TO ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR EXACT LOCATION OF ALL ELECTRICAL DEVICES PRIOR TO COMMENCING INSTALLATION 2. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE AJ., I UAL PVJI 1 IVIV VI- 1 HE U r%%-,ul I BREAKERS IN I HE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. 3. REFERENCE SHEET E102 FOR PANELBOARD BOUNDARIES INDICATING PANELBOARDS SERVING THIS SPACE. 4. ALL 480Y/277V, NORMAL BRANCH CIRCUITS 'NH' FEEDING AREA SHOWN SHALL BE FED FROM "NH" PANELS, AS NOTED. 5. ALL 208Y/12OV, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NL' PANELS, AS NOTED. 6. ALL 208Y/12OV, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. 7. ALL 208Y/12OV, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. 8. "RC" AS IN "RC-**" INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/2AL UNLESS OTHERWISE NOTED, REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 9. ALL EMERGENCY BATTERY UNIT (EBU) LIGHTS SHALL BE WIRED TO UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA WHERE EBU IS LOCATED. KEYED NOTES - Q 1. REFER TO DETAIL 1/E501 FOR MORE INFORMATION. 2. REFER TO DETAILS E1, E5, C5 ON SHEET ID802 FOR MOUNTING HEIGHT OF TYPE "P10", TYP. 3. REFER TO DETAILS D1, D3, D5 ON SHEET ID801 FOR MOUNTING HEIGHT OF TYPE "P12" 4. REFER TO DETAILS E2, E3 ON SHEET ID803 FOR DETAILS. A J "SUMMIT SMITH DEVELOPMENT 741 N Rrnad,niay Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD 93M 77 J CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & w DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.coi RD Project Number: 218092.00 \��Ilrrill�� G 0 N N6CT ^d `. No. 0033339 4 Z- O O U O L W o 4— C/) ® c� �- (3) U � i. N O W C-0 U C O a = C ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA B - LIGHTING J J vi U N C C_ Sheet Number: U C6 N Y O ti M M CV 0 N M TRUE PLAN NORTH NORTH SECOND FLOOR PLAN - AREA B - LIGHTING 1/8" =1'-0" SHEET NOTES - A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. O"SUMMIT SMITH DEVELOPMENT 941 N Rrrlarl\A/a\/ lei NH/2-1 (480Y/277V NORMAL) I NL/2-6 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) $'TR I OS-10 TECR EM-8 TR TR N L-64 N L-(-8 I GFI N L-66 TR NL-68 GFI TR NL-66 NL-641 u NL-68 TR r 60" AFF TUR ® I NL-58,60 GFB ®MVRV-A NL-65 TV Cl NL-57,59 NL-65 OS-3 ® MVRV-A MVRV-A GFI I NL-57,59 NI-5715G NL-65 NH/2-1 (480Y/277V NORMAL) TR ® MVRV-M NU2-6 (208Y/120V NORMAL) NL-67 NL-57,59 EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) D R NH/2-1 (480Y/277V NORMAL) GFI TRTR NL-711 NL/2-5 (208Y/120V NORMAL) GFI NL-69 EM/2-2 (208Y/120V EMERGENCY) TR NL-103 TR =0 OS/2-2 (208Y/120V OPTIONAL STANDBY) NL-105 m MVRV-M NL-73 I GFi NI _R7 FQ TR TR NL-79 NL-105 ($ NL-105 I TR TECR <=I ®80 ® MVRV-A TR TR NL-67 TR EM-8 TR NR-7� NL-86,88 NL-79 OS-10 1 NL-69 NL-73 MVRV-J Lo ® ��-----®( -_7� NL-86,88 I I ® MVRV-A I 5 MVRV-B NL-86,88ED I E301 ® NL-86,88 NL-82 TR I N L-79 ® MVRV-J NR L-79 TR NL1 NL-61 NL-86,88 OS-1 I ® NL2 NL-62 GFI NL-66, 8 iJL3 INL-63 TR THD THD NL_89 NL4 NL-64 �NL-84 NL-79 NL-81,83 NL-85,87 ® I NL5 NL-65 - - M 6 ® ® MBS-B I NL7 NL-69 1 ®MDSS-1 , NL-86,88--------- 9 NL-91,93 I--' ®MVRV-A E303 I I N L-86, 88 I I 0 5 TR TR9 TR IU I TR NL-96 NL-96 NL-89 ®� N L-96 6 ®MVRV-J TECR NL-90,92 EM-10 I NL1 NL-70 ® MVRV-J MVRV-F NL2 NL-71 �FBTR NL-90,92 NL-76,78 NL3 NL-72 X NL-94 60" AFF 36" AFF TR I NL4 NL-73 TV TR NL-96 NL5 NL-74 1 - - - - - NL-94($ ll IVL-94 OS-1 I NL7 NL-77 I I NL1 NL-10 DID NL-98 --------- I NL2 NL-11 $ I OS-5 TR r- I NL3 NL-12 E301 I NL-98O� OS-1 NL4 NL-13 DIR OF LIFE ® MVRV-M NL-100 NL5 NL-14 I NRICHMEn'-` MBS-B 2 NL-98 NL-90,920 ® NL-90,92 TR NL7 NL-17 OS-1 E300 I I NL8 I Nil-19 I NL-98 TR I 4- I I NL-G001 � O OS-7 ®MVRV-K N L-90, 92 NI 1I- N-I I _1� I .� ! MVRV-K I NL2 NL-2 1 10 NL-90,92 NL3 NL-3 I I MVRV-I I L - E303 NL4 NL-4 MVRV-H I NL-16,18 I NL5 NL-5 NL-6,8-Mtn------------� I NII 7 1 NI q m I .r `W _- TCr`D _ TR IVIVRV-A I K ' `l1 ® OS-7 - - - - NL-104,106 OS-7 TECR ®� EM-2 EM-14 60" AFF 60" AFF 60" AFF NL1 NL-20 MVRV-A ® MBS-B ® TV TV TV NL2 NL-21 MVRV-H I ® NL-104,106 NL-104,106 NL3 NI NL-26,28 1 r - - - - - - - - - - - - - ' 1 TR I I OS-7 6 NL-99 NL-99 NL-101 1 1 MVRV_P \ I NL4 NL-23 ® I ® I \ E303 / ® NL-99\ NL-101' NL-101 TR � `� NL-104,106 [III NL5 NL-24 NL-106 r Il NL7 NL-27 4)� I MVRV-G TRD NL-36,38 NL-111,113 I j GFI TR I® TRW GFB I I NL-100�I I NL-102 I® -- -- -- TRD NL-107 I I- ® NL 104,106 NL 9 92 ® r 2 1 NLA15,117 ®I NL1 I NL-29 1 6& i ' (A) 1 E300 TRW �� NL2 NL-30 MRV-G I TR OS-7 I TR MVRV-G I I TR GFB I NL3 NL-31 ( NL-48,50 L - - -� NL-102 - - NL-58,60 NL-106 NL-109 NL4 NL-32 r ----------� I $$ NL5 NL-33 I NL7 N L-35 I I I I i --- - - NL8 NL-37 - - - � NL1 NL-43 NL1 NL-52 NL2 NL-44 NL2 NL-53 ---� I NL3 N L-45 I NL3 N L-54 NNL4 NL-46 I ^ NL4 N L-55 L5 N L-47 / 5 \ NL5 NL-56 I NL7 NL-59 E300 I E300 NL7 I NL 59 II ---------------J-----------------I TRUE PLAN NORTH NORTH SECOND FLOOR - AREA B - POWER 1/8" = 1'-011 ® MVRV-A NL-58,60 IK TR s-N L-62 N L-64 TR TR �� OS-10 NL-62 NL-62 $=TR ® 6 N L-62 MBS NH/2-1 (480Y/277V NORMAL) NL/2-5 (208Y/120V NORMAL) EM/2-2 (208Y/120V EMERGENCY) OS/2-2 (208Y/120V OPTIONAL STANDBY) ® MVRV-J OS-14,16 B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE AC I UAL PVSI I IOIV OF I HC C RCUl T BREAKERS IN I HC PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. C. ALL208Y,120V, NORMAL BRANCH CIRCUITS'NL' FEEDING LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' PANEL NUL-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL COMMON OR PUBLIC SPACES SHALL BE FED FROM 'NU PANEL NUL-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS'NL' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL AS NOTED. F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHVVVIV SHALL BE FED FrCVIV1 'IVL r 1\4 S, AS IVV T CD. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NOTED. I. E.C. SHALL REFERENCE LOW VOLTAGE'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR ALL FINAL ROUGH -IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEIVIS SfUTALL INCLUDE. - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE -TELECOMMUNICATIONS, DATA NETWORK - EMERGENCY CALL SYSTEM - CABLE TELEVISION -AUDIOVISUAL, SOUND SYSTEM -WIRELESS NETWORK - EMERGENCY TWO WAY COMMUNICATION SYSTEM J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. SHALL PROVIDE 208Y/120V AND 480Y/277V NORMAL POWER, ESSENTIAL POWER AND NON -ESSENTIAL POWER, AS REQUIRED FOR A COMPLETE AND OPERATIONAL LOW VOLTAGE SOLUTION. K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENT POWER CIRCUITS. L. E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. COORDINATE EXACT LOCATION OF POWER CONNECTION WITH APPROVED FIRE PROTECTION SYSTEM CONTRACTOR. KEYED NOTES - a 1. E.C. SHALL PROVIDE 4" X 4" JUNCTION BOX ABOVE ACT CEILING FOR THE INSTALLATION OF EMERGENCY CALL REPEATER. E.C. SHALL HARDWIRE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE FINAL INSTALLATION REQUIREMTNS WITH APPROVED LOW VOLTAGE VENDOR. 2. E.C. SHALL PROVIDE 2-GANG RECESSED MEDIA TYPE OUTLET FOR POWER/TV/DATA CONNECTION. MANUFACTURER SHALL BE LEVITON 69OW SERIES OR EQUAL. REFERENCE LOW VOLTAGE DOCUMENTS FOR ADDITIONAL INFORMATION. 3. E.C. SHALL PROVIDE DEDICATED CIRCUIT, AS SHOWN TO EACH STYLING STATION. EACH STYLING STATION IS PROVIDED BY THE MANUFACTURER WITH (1) QUAD AND (2) DUPLEX OUTLETS. E.C. SHALL PROVIDE AN ENTRY POINT INTO EACH STATION AND WIRING CONNECTION TO EACH OUTLET. COORDINATE EXACT INSTALLATTON REQUIREMENTS WITH APPROVED MANUFACTURER. 4. E.C. SHALL PROVIDE (2) SINGLE GANG JUNCTION BOXES WITH VC FOR INSTALLATION OF GAMING EQUIPMENT. ONE SINGLE GANG JUNCTION SHALL BE MOUNTED AT 24"AFF WITHIN CASEWORK, ONE SINGLE GANG JUNCTION SHALL BE MOUNTED AT 60"AFF BEHIND WALL MOUNTED TELEVISION. EACH JUNCTION BOX SHALL BE MOUNTED ADJACENT TO POWER/TV/DATA OUTLETS BEHIND THE TV AND WITHIN CASEWORK. (TYPICAL AT ALL (3) TV/GAMING LOCATIONS). IONS). Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com C D UUINO 1 r\uu 1 IUIV JtKVluto 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 n RING HATEAU C 174001 A/est Cunif-i n,i,,, _ Rrn,Itficlrl 1AII 53n45 IJILVI ✓IV - , Phone: 414.778.1700 / IV Fax: 414.778VIV.: 360 I r-d@ringdu.col RD Project Number: 218092.00 0 N N,4-c", . ?HE co co ; <� 1 , LL No. 00333 O" St#,, e\\ r w� Z_ - I-- mr, se CU �t O O C U O 21.- N F, W O 4-- U) V � cu CU N L L U 2' L CU O W Z p, :D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION s Sheet Name: SECOND FLOOR PLAN - AREA B - POWER ¢Sheet Number: C_ co NE204P Y 0_ 0 ram, UM1�Vi7I T SMITE I/3IL° VF, LOPMEN 0 SP 11 I I 3 I E300 I I I I I I I I I I I I I I I I I I I I I I I 3 I I E300 I f� W z m O ry 0 ry rn I 0 N 0 ZD W n M d- l.Ci M N 0 N o a SP SP 0 0 SP SP 10 V01 /C SP 0 ❑F VO 1 /C EV2-1 SP OF HC EV2-1CM EV2 2 CMn EV2-3 II CM FF1 EV2-4 I 9 I I E301 I I I I I I I OF TS OM M [FFS [FCM I I RF I I PS 0 \/n 1 OF SP TOP OF ❑F HC I SHAFT HV2/C IER ,SUB RCju 2015 SIR OF L IFF_ ENRICHMENT 2013 201 ❑F 0 V01/C SP SP 10 SP 0 0 HV1/C SP OR 201 SP FM 0 HV1/C SP 0 FM 10 V01/C V01/C SP FR HV3/C HV1/C 0 SP SP FF I I a HV1/C I I I I 0 I 0 6 0 E301 0 I V01/C�®®---_—_—� FR I SP 0 u e 0 0 0 6 I E301 i�uRK � I 2003---------� HV1/C SP 0 [F] 0 IE SP ❑F SP ❑F HV1/C SP RIEF1 HV1/C PS 0 0 V01 /C ao OF HV1/C SP HV1/C SP I I V01/C E SP In00 SP ❑F SP ❑F V01/C SP HV4/C -___--- I I I I I SP 9 I —I o r" I I E301 I — — 6 — — I 6 i I E300 E300 I I I LJ TRUE PLAN NORTH NORTH SECOND FLOOR - AREA B - TECHNOLOGY OC FS TS A � 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax:414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & L DUCHATEAU 174no West Canitnl nrive - Rrnnkfield WI W45 Phone: 414.778,17001 Fax: 414.778,23601 r-d@ringdu.col RD Project Number: 218092.00 \\\111Ii111f ff CO N N6cT •,,o p? H E R Gy . ✓�, G No. 0033339 C O O � U o >� W o 4— C/) 0 r� (3) i L 0 w U —0 C-0 . o CCU Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA B - �TECHNOLOGY J ._I N U N U Q Sheet Number: U Ca E204T C d O SHEET NOTES - w z M ry rnl 0 N1 w F__I U LL 0 0 2 M I N M O 00 a� U 0 0 W 0 L i U) L& 0 co M N rn 0 CV L-� I L-J �- L-J 1 L __J -' - ------ I I r FH NL7 I NL-7 1 I NL7 NL-19 I EM-14U FH NL8 I NL-8 NL8 4 NL-20 E302 EM-14U I E302 � I �n N15I�N 1 1 1 1 I I I I I I I I 1FH EM-14U FH =Rfi �IA1 I 1 1 1_1V1 1-r1 Wll )_�W5 ----- )�W5 � W5 ----- :ff�W5 �------ )-�W5 � � ©2.12 RD-1 RD-1 RD-1 RD-1 RD-1 XF WF DC DC DC DC DC DC DC DC EM-11 U M-11 U DA DA O RD-2a OEM-14U OEM-14U 0 RD-3c OEM-14U O RD-3c OEM-14U O RD-3c O O O ODA 0RD-2a OW5 XF RD-2 P18 P18 DA DA DA EM-14U W5 P18 RD-2 RD-2 EEM-14U RD-3b RD-3b —©2.09 — — — :qRD-1 EM-11U P18 DC DC DC RD-3 DA DA /� DA �1 /� lJnn n_ l/nn n� \)-- n_ mm� n_ \/nn nl- Ohfi AAI I KU-Ld - RU-Gd " KU-Gd DC DC DC DC , KU-Jl. - KU-JU - Ctvl- I-FU NL5 NL-31 I ORD-3c ORD-3c DC 0RD-3c ORD-3c 0RD-3c RD 2 RD 2 RD 2 pC_ RD-1 15 RD-1 DA DA DA DC DC DC EM 14U P15 DC ORD-3c ORD-3b ORD-3b 0 RD-2a 0 RD-2a O RD-2a II --------a 10 0 DA 0 RD-11 DA OEM-14U EGRD-11 ORD-11 XG 1LM_11U EM-11 U © r �—� -------- DA DA ORD-11 ORD-11 2'n t4 I I DA u ..' 1 E302 I RD-11 I RD-1 RD-4 DA DA ORD-11 ORD-4. I I �I i� NL7 NL-49 I OO DA DA WI NL7 NL-61 L — — — — — — — J I NL8 NL-50 1 RD-11 RD-11 _ RD-1 NL8 NL-62 Ii DA DA EM-14U c-)S EM-14U AA NH B NH-7 AA � E302 ms/ B P20 P 2 0 0S aTA P20 RD-4 a NH-7a TAa T1 RD-4 Ii 1 --► 1 RD-1 —� TA TA NH-7b RDA DA TA T1 O RD-4 NH-7b DOA WE AAF RD-4 NH-7 �� t' 1 _L MA I/lCl �t H-7 6 v„O 1""l NH-7 B H' I OS B DA DR W5 EM-14U FC EM-14U RD-1 NH-7 NL7 NL-7 1 9 - NL7 NL-31 NL8 NL-8 FC RD_ NL8 NL-32 �-I I NH-7 OD I P20 P20 i I RD-4 Ll RD-4 i 1 i E302 XF I O O O O �I E302 � DA LI RD-4 DA XF DA P20 DA EM-11 U EM-14U RD-4 EM-14U RD-4 r I W5 RD I RD-1 D �-7 B NH-7— pA RD- RD-4 OS RD-4 FC FC NL7 NL-19 O NH-7 NH-7 O NL7 NL-49 NL8 NL-20 I DA r77— DA I NL8 NL-50 W5 EM-14U EM-14U RD-1 I� 1 W5�1 OS B AA RD-1 B NH-7 DAO 2.14 AA OS O DA RD-4 2—► NH-7 +— RD-4 �—------� XF XF AA EM-11 U i 4 I I 1 I X EM-11 U NH-7 DA Q E302 I XFx NH-70 B 4 ODA I E302 E302 I I EM-11 U OS B AA OS 1-- RD-4 N H-7 NL5 NL-97 1P20 NH-7 4 XFX 2.16 RD-5 EM-11 U P20 W5 :�J NH-7 0 0 RD-1I RD-6 CID ❑ � DA NH-7 W51 EM-14U - i OS B RD-6 O CID I I 1 -1 CID DA XG 1:1 NH-7 MEM-11 U NH-7 -144UL- xG L---------J NIL8 LB LB LB L 2.19 LB DA EM-11 U DA DA DA L. ------ J O RD-9e O O RD-9e O RD-9e0 O O RD-9e O O O c 0 O O RD-6 DC DC DC 0 pC e d DC DC 0 DC RD-8f DA RD-8f RD-7c RD-7c OS �--- P20 EM-141 RD-8d EM-14U RD-8d EM-14U):�RD-8 P21 RD-8d EM-14U RD-8d RD-8fOP20 P20 ❑ g P21 P21 P21 RD-8 )RD-7 RD-8 RD-8 RD-8 RD-8 AA _AW DA DA DC DC DC DC DC DC DC DA DA DA DA NH-7 0 RD-8g OEM-14U O RD-8d 0 RD-8d 0 RD-8d 0 RD-8d 0 O RD-8d O RD-8d 0 RD-8d 0 0 OEM-15U O RD-8f O RD-7c OEM-15U NH-7 DC DC DC DA XF P21 RD-8d P21 RD-8d P21 RD-8d RD 8 OEM-14U O OEM-11 U 2.21 P20 RD-8 W5 P21 W5 RD-8 W5 )2� )ZID-720 ❑-i DA RD-8 DC- �"� DC- RD-6 RD-6 RD-6 DC- R -8DC- DA DA- M DA- / RD-8 RD-8f RD-Sg DA RD 8d EM 14U DC DC RD 8 EM 14U RD 8f RD 8f XF DA DA XF OP20 O W5 0RD-8g 0 LB 0 RD-8d LB DCO ORD-8dLB DC 0 0 LB O C�(XG 0 W5 0 EM-11U ORD-7c ORD-7c EM-11 U RD-10 RD-6 RD-9e RD-9e EM-14U c RD-9eEM-14U RD-9e Jn�t EM-11 U gRD-6 )K- �©2.20 2.22 — — — — — — — — — — — — — — — — — — — — — — — — — — — DDA DA�— —�— —� � FH fORD-27f ORD-17f I I I EM 14U FH EM-14U I I I I I I I I I I I I NL5 NL-89 4 NL7 NL-61 1 I NL7 NL-73 I E302 NL8 NL-62 NL8 NL-74 FH 1 E302 I E302 I I EM-14U FH EM-14U I - - I - - L------ -J L__J- -L_-�-L-._L-T -L- s -L-J TRUE PLAN NORTH NORTH SECOND FLOOR PLAN - AREA C - LIGHTING 1. REFER TO ARCHITECTURAL PLANS, ELEVATIONS, AND DETAILS FOR EXACT LOCATION OF ALL ELECTRICAL DEVICES PRIOR TO COMMENCING INSTALLATION 2. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL DrICITlr1Nl nr TI-II= (-IRr`I IIT RP1=AWPPC INI TWr= V VI I1- VI II IL 11\ V 1 IIY IL PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. 3. REFERENCE SHEET E102 FOR PANELBOARD BOUNDARIES INDICATING PANELBOARDS SERVING THIS SPACE. 4. ALL 480Y/277V, NORMAL BRANCH CIRCUITS 'NH' FEEDING AREA SHOWN SHALL BE FED FROM "NH" PANELS, AS NOTED. 5. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NL' PANELS, AS NOTED. 6, Al 1208Y/120\/ NON_FSSFNTIAI SYSTFM CIRCI_11TS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. 7. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM 'EM' PANELS, AS NU T ED. 8. "RD" AS IN "RD-**" INDICATES A RELAY CONTROL CIRCUIT FED FROM LIGHTING CONTROL PANEL LCP/2MC UNLESS OTHERWISE NOTED. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR CIRCUIT AND CONTROL INFORMATION. 9. ALL EMERGENCY BATTERY UNIT (EBU) LIGHTS SHALL BE WIRED TO UNSWITCHED LIGHTING CIRCUIT SERVING THE AREA WHERE EBU IS LOCATED. KEYED NOTES - Q 1. TYPE LB SHALL BE MOUNTED AT HORIZONTAL TRIM, HIDDEN FROM VIEW WITHIN COVE, TO UPLIGHT WALLS, TYP. A ®®SUMMIT SMITH DTE VEL OPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com MCD A I lk/�G7�I CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & U DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.col RD Project Number: 218092.00 (� O N NFCT ^d No.003330 r G i - / 1,. � o o � U L O L W O O N iL U �' O ui U co Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA C - �LIGHTING J J N U U ¢Sheet Number: C_ U E205LCU 0 n pop- TSLIMMIT SMITH DEVELOPMENT u.l z m O ry MI 0 NI w �I U O Lil C_ U 0 .n c6 U rn n ,'I- C) N W NL1 NL-1 I NL1 NL-13 NL1 NL-33 NL2 NL-2 2 I NL2 NL-14 2 e 5 NL2 NL-34 NL3 NL-3 E302 I NL3 NL-15 E302 I E302 NL3 NL-35 NL4 NL-4 NL4 NL-16 NL4 NL-36 NL5 NL-5 I NL5 NL-17 NL6 NL-6 I NL6 NL-18 I MVRV-E MVRV-E I MVRV-E MVRV-E MVRV-G NL-9,11 NL-10,12 I NL-21,23 NL-22,24 f NL-38,40 RTR TR TDH OS-7 OS-7 TR EM-3 OS-9 ® MBS OS-11,13 TECR ci ® EM-4 MVRV-F NL-28,30 I TR NL-67 I I TDH TR EM-1 OS-7 ®MVRV-P OS-11,13 9 TR N L-67 MVRV-M MVRV-P OS-11,13 2 ® OS-11,13 OS 11,,13 ® ® E306 r----- I I TR I I OS-1S, P TR TR N L-67 I----�OS-7 �OS-9 -------� NL1 NL-25 I NO NL-43 I COUNTRY I NL1 NL-55 NL2 NL-26 I NL2 NL-44 I@= TR I I TR �I NL2 NL-56 KITCHEN NL3 NL-27 I NL3 NL-45 OS-9 NL3 NL-57 FJ NL4 NL-29 5 I I NL4 NL-46 032 I OS-9 E302 I ® NL4 NL-58 I NL5 NL-47 ® I ® I I ® MBS-A I MVRV-D INL5 I NL-59 NL6 NL-48 MVRV-E MVRV-P I I OS-15,17 NL-63,65 NL6 NL-60 NL-51, 53 I OS-15,17 ® MVRV-A I TECR OS-15,17 ® EM-6 I I I IO I I I L-(P TR I N L-68 I MVRV-E I ®MVRV-A I OS-2,4 TR =@ 2 2 NL-52,54 TR NL-68 E302 ® I OS-9 VTR TR I ® E302 NH/2-2 (480Y/277V NORMAL) r I =@ NL-68 NL-68 I MVRV-D Li N L-64, 66 NU2-3 (208Y/120V NORMAL) EM/2-1 (208Y/120V EMERGENCY) I GFI GFI TR OS/2-1 (208Y/120V OPTIONAL STANDBY) NL'70 NL-70=0 NL1 NL-1 OS-9 - NH/2-2 (480Y/277V NORMAL) NL1 NL-25 NU2-4 (208Y/120V NORMAL) I NL2 NL-2 EM/2-1 (208Y/120V EMERGENCY) NL3 NL-3 I ® �- _T NL2 NL-2 OS/2-1 (208Y/120V OPTIONAL STANDBY) NL4 NMVRV-A L-4 I 11 I ® I ® NL3 NL-27 NL4 NL-28 MVRV-A NL6 NL-5 ® I OS-2,4 E303 I I OS-2,4 I MVRV-D NL5 NL-29 FJ N L-9,11 NL6 NL-6 MVRVI ® MDSS-2 I NL-33,35 NL6 NL-29 NL-71,731 Fi I I I I L_ ®_ _JMBS ® I I ® MVRV- OS 2,4 TECR OS-6,8 ® EM-8 TR MBS-A 6 OS-19 2 ® I ®S-6,8 TR - ® I ® 2 FJE302 MVRV-E GFI MBS MVRV-D E302 NL-10,12 I TR =@ NL-72 TRW TRW OS-6,8 I NL-34,36 OS-19 TRD G B GFB TR TRD NL-82,84 NL-74 NL-76 --------- NL-111,113_* (& _® ®- OS-=----___--� NL1 NL-13 1 g NO NL-43 NL2 NL-14 I % I NL2 NL-44 NL3 NL-15 I L _ - - - - _ E303 I NL3 NL-45 NL4 NL-16 VTR TR= NL4 NL-46 Fi NL5 NL-17 MVRV-E I NL-81 NL-81 I MVRV-D NL5 NL-47 NL6 NL-18 NL-21,23 MVRV-A I NL-51,53 NL6 NL-48 OS-6,8 r-------� I TUCR I III NL1 NL-93 I I OS- 5 NL2 NL-94 I GFI S-23 NL-79 GFI E302 NL3 N L-95 I N L-79 NL4 NL-96 ILi - I JLLJ:- 4 TR '074A DIDI I 2 I OS-� OS-21 DID I 2 E302 ® I qp NL-80 DID � TR I ®RV-D E302 II I MVRV-E I CAF`. NL-82 N L-80 OS-25 I NL-52,54 N L-22,24 PA RT N' MVRV-G TDH NL-98,100 I I I EM-5 ® NL-82 OS -21 ® L---------_J ® 8 ® MBS-AL---------� 9 MVRV-Q M Ro 12 9 OS-6,8 68 L---------1 I TR TR TR �TR ®a OS-29 TR OS-27 OS-,MVRV- OS-27 NL-25 TR NL-108 TECR ®10,12 60 FB NL-106TR EM-12 TV NL OS 25 N L-106 =@ TFP2 TFP2 N L-102 N L-104 TDH ® MVRV-J EM-9 ® MVRq NRL106 OS-14,16 TFP2 TFP2 O OS-29 S-29 TR TR 14, 6 TR 0 TR MBS-A TECR TR � ® TR OS-29 6OS-27 OS-10,12 �OS-25 - EM 7 EM-10 �NL-91 �NL-108 r------------------------------ 1 ® 6 OS-14,14 MVRV-E ® ® MVRV-D NL-63,65 NL-64,66 I R56 NL-R NL-7, 76, 8 I NL-90,92 I I I I NO NL-55 I NL1 NL-67 NL2 NL-56 I NL2 NL-68 NL3 NL-57 NL3 NL-69 NL1 NL-85 NL4 N L-58 I NL4 N L-70 I N L2 N L-86 NL5 NL-59 I NL5 NL-71 I NL3 NI-87 5 NL6 N L-60 YE302 I NL6 N L-72 2 I NL4 N L-88 E302 E302 TRUE PLAN NORTH NORTH SECOND FLOOR - AREA C - POWER NH/2-2 (480Y/277V NORMAL) NU2-3 (208Y/120V NORMAL) EM/2-1 (208Y/120V EMERGENCY) OS/2-1 (208Y/120V OPTIONAL STANDBY) NH/2-2 (480Y/277V NORMAL) NL/24 (208Y/120V NORMAL) EM/2-1 (208Y/120V EMERGENCY) OS/2-1 (208Y/120V OPTIONAL STANDBY) SHEET NOTES - A. E.C. SHALL REFERENCE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. B. CIRCUIT NUMBERS INDICATED DO NOT REFLECT THE ACTUAL POSITION OF THE CIRCUIT BREAKERS IN THE PANEL; RATHER, THE NUMBERS INDICATE WHICH DEVICES ARE CONNECTED TO A COMMON CIRCUIT. C. ALL208Y,120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL RESIDENT ROOMS SHALL BE FED FROM 'NL' PANEL NUL-1. D. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING LOWER LEVEL COMMON OR PUBLIC SPACES SHALL BE FED FROM 'NU PANEL NUL-2. E. ALL 208/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING FIRST LEVEL AREA SHOWN, SHALL BE FED FROM 'NU PANEL AS NOTED. F. ALL 208Y/120V, NORMAL BRANCH CIRCUITS 'NL' FEEDING AREA SHOWN SHALL BE FED FROM 'NU PANELS, AS NOTED. G. ALL 208Y/120V, NON -ESSENTIAL SYSTEM CIRCUITS "OS" FEEDING AREAS, AS SHOWN, SHALL BE FED FROM 'OS' PANELS, AS NOTED. H. ALL 208Y/120V, ESSENTIAL SYSTEM BRANCH CIRCUITS "EM" FEEDING AREAS, AS SHOWN, SHALLBE FED FROM'EM' PANELS, AS NOTED. I. E.C. SHALL REFERENCE LOW VOLTAGE 'TS SERIES' DRAWINGS AND SPECIFICATIONS FOR ALL FINAL ROUGH -IN REQUIREMENTS AS IT PERTAINS TO ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. LOW VOLTAGE SYSTEMS SHALL INCLUDE: - SECURITY, ACCESS CONTROL - SECURITY, SURVEILLANCE -TELECOMMUNICATIONS, DATA NETWORK - EMERGENCY CALL SYSTEM - CABLE TELEVISION -AUDIOVISUAL, SOUND SYSTEM -WIRELESS NETWORK - EMERGENCY TWO WAY COMMUNICATION SYSTEM J. E.C. SHALL REFERENCE FINAL LOW VOLTAGE 'TS SERIES' DRAWINGS FOR FINAL POWER REQUIREMENTS FOR ALL LOW VOLTAGE SYSTEMS, EXCLUDING FIRE ALARM. E.C. SHALL PROVIDE 208Y/120V AND 480Y/277V NORMAL POWER, ESSENTIAL POWER AND NON -ESSENTIAL POWER, AS REQUIRED FOR A COMPLETE AND OPERATIONAL LOW VOLTAGE SOLUTION. K. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENT POWER CIRCUITS. L. E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER CIRCUIT TO FIRE PROTECTION DRY PIPE ASSEMBLY AIR COMPRESSOR. CIRCUIT SHALL BE FED FROM EM/1-2, 18. COORDINATE EXACT LOCATION OF POWER CONNECTION WITH APPROVED FIRE PROTECTION SYSTEM CONTRACTOR. KEYED NOTES - a 1. E.C. SHALL PROVIDE 4" X 4" JUNCTION BOX ABOVE ACT CEILING FOR THE INSTALLATION OF EMERGENCY CALL REPEATER. E.C. SHALL HARDWIRE EMERGENCY CIRCUIT TO THE ELECTRICAL LEADS OF THE LOW VOLTAGE PROVIDED TRANSFORMER DEVICE. COORDINATE FINAL INSTALLATION REQUIREMTNS WITH APPROVED LOW VOLTAGE VENDOR. 2. E.C. SHALL PROVIDE 2-GANG RECESSED MEDIA TYPE OUTLET FOR POWER/TV/DATA CONNECTION. MANUFACTURER SHALL BE LEVITON 69OW SERIES OR EQUAL. REFERENCE LOW VOLTAGE DOCUMENTS FOR ADDITIONAL INFORMATION. 3. E.C. SHALL PROVIDE LEVITON 47617-REB, LOW PROFILE BOX WITH COVERPLATE 003-4767-LPF FOR INSTALLATION OF LOW VOTLAGE EMERGENCY CALL REPEATER DEVICE. REFERENCE TS SERIES DRAWINGS, SHEET TS511 FOR ADDITIONAL INFORMATION AND MOUNTING REQUIREMENTS. INSTALLATION OF RECESS BOX WITHIN FIRE RATED WALLS SHALL BE COORDINATED WITH GC PRIOR TO INSTALLATION. 241 ITV. QUroauway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 1CD MRqU7X CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com �' f ret t5 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 \\\��IIIII(IJJJ/ PH E r� No. 0033339 C O O U O i N L >� W O a) >, CIO L U L O CD � W C-C) U CIO Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA C - POWER Q Sheet Number: U .N CU "SUMMIT SMITH DEVELOPMENT 941 N Rm-gdxA/av fW UJ z O ry A �I 0 NI LU U w CU U 0 L U ►0 a M 0 cm CM N 0 N J- 3 -L_I 3 I 6 I E302 I E302 I E302 I I I I I I I I I i I I I i I I I I I I I I I I ❑F OF FS TS RR SP ❑F HV1/C I I I I I I I I I I I I 6 I E302 I I 6 I I E302 I I I I I I I I I I I I I PS 0 HV3 a SP 0 0 HV1/C SP SP SP 0 pF O 0 0 0 HV3/C HV2/C HV3/C SP FJ I I I I I 3 I E302 HV1/C I I n i SP I I I I I I I i i I 3 I E302 I I I r I SP I I I I I HV1/C I � Fi I I SP [F DP � [E] DH 3 I CM 0 CM E302 DP DH DH IODH❑SP 1 ° HV1/C I I I I HV3 0 0 SP SP 0 V01 /C 0 SP 0 SP SP 0 0 VO 1 /C ❑F HC 0 VO 1 /C 0 MM a SP a V01 /C V01 /C 00 HC 0 SP VO 1 /C ❑1= 0 VO 1 /C CM DH 0 DH 0 DP OF rM HV3 0 PS SIP 0 I ri I I I I I 3 I I E302 I ri I HV1/C i IFI i S I SP I I I I I I I I I I 3 I I E302 I rj I I 0 I i SP I I I I I I HV1/C I I I 3 ❑ SPD F I 0 DP E302 CM01 DH OF SP o I HV1/C I I I 0 SP ---------------1--------------I----------I I I I I I i I I I I I I I I I I I I I I I I I 6 I I 3 I 3 I E302 E302 I TE302L_f -L__.S -LS Z_J TRUE PLAN NORTH NORTH SECOND FLOOR - AREA C - TECHNOLOGY '��7'�:17118" =1'-0" HV3® Psp Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD 7C� CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 1-6-011 DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778,17001 Fax: 414,778.2360 / r-d@ringdu.coi RD Project Number: 218092.00 Ike C O O � U 0 s: (D21 O L � W O 4— U) 0 A N L. U L N 0W ^ U C-0 O C a Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SECOND FLOOR PLAN - AREA C - TECHNOLOGY L a Sheet Number: U) E205TY F: w z m O ry rn I O N w i I —I w U) M C- 0 c6 NI O O 00 c E U 0 0 W 0 0 0 0 W MCU-1A MCU-3A NH/2-1 MDSS-1 m NH/2-1 /i\ m A c G,Y,V N L-95, 97 14,16,18 MCU-313 NH/2-1 ® ® MCU-1 B NH/2-1 20,22,24 8,10,12 MCU-46 MCU-4A NH/2-1 ® ® NH/2-1 25,27,29 19,21,23 MCU-2B MCU-2A OSH/1-1 ® ® OSH/1-1 8,10,12 2,4,6 WP GFI N L/2-3 90 MDOAS-1 MSB a MAU-1 ® MSB ®KCU-1 NH/1-1 36,00,40 ® KCU-2-2 NH/1-1 42,44,46 MCU-8 MCU-11 ® NH/2-2 (� NH/2-2 17,19,21 11,13,15 WP GFI N L/2-3 86 WP MRTU-1 GFI MSB NL/2-3 92 NH/2-1 ® MDOAS-3 NH/2-2 13,15 <= 20,22,24 WP GFI NL/2-3 MDSS-2 88 ® N L/2-3 MDOAS-2 ® 76,78 NH/2-1 < MDSS-3 7,9,11 MCU-9A ® NH/2-2 ® MCU-12A OSH/1-1 14,16,18 1,3,5 ® MCU-9B ® MCU-12B MCU-5A MCU-5B OSH/1-1 ®NH/2-1 ® NH/2-1 ,4,6 2 7,9,11 31,33,35 37,39,41 MCU-6A MCU-613 ®NH/2-1 ® NH/2-1 1,3,5 26,28,30 MCU-10 ® NH/2-2 MCU-7 ® NH/2-2 8,10,12 26,28,30 TRUE PLAN NORTH NORTH ROOF PLAN - ELECTRICAL 1/16" =1'-0" KEYED NOTES - a 1i: E-C. SHALL PROVIDE SMOKE DETECTORS AT SUPPLY AND RETURN FOR DEDICATED OUTLDOOR AIR UNITS. COORDINATE INSTALLATION REQUIREMENTS WITH MECHANICAL CONTRACTOR. 2.. E.C. SHALL PROVIDE SMOKE DETECTORS AT SUPPLY AND RETURN TO THE ROOF TOP UNIT (RTU-1). COORDINATE INSTALLATION REQUIREMENTS WITH MECHANICAL CONTRACTOR. �9. -1P CIRCUIT CONNECTION AT HEAT E.C. SHALL PROVIDE 277 TRACE CONTROL PANEL. COORDINATE EXACT LOCATION AND CONNECTION REQUIREMENTS WITH MECHANICAL CONTRACTOR. 19)IE VIET, (0I' IP/0r�A-,\r� 241 N. Broadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 1 CD 1WM�7D--:fl kaulNlj I rnuu I IUN jERV1U[z0 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778,2360 / r-d@ringdu.coi RD Project Number: 218092.00 .� CONNF \ A� ��'?HER No. 0033339 44,E wfe-pll Z-- I- /1, W C CU (3) N o w U U CIO .y O � -N C— Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ROOF PLAN - ELECTRICAL M U Sheet Number: E206 T CB U C d SHEET NOTES - 1. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENTS POWER CIRCUITS PER NEC SECTION 210.12. ®®SUMMIT SMITH , ) TH VEL OPMENT 241 N. Broadwav w z m O ry ri rn� O N n ■ U DS TREF DF 3a NL6a GFB TR � NL6e NL'I IVLL DS 0 NL6e TR GFI 0 TR NL2 U4 DS GFI NL5 TR NL6d NL6a s-GFI DS DS NI-7 NL6a NL6a TR ed 0 0 GFI NI-2 0 DS NL6c TR �- TV c- GFI qPTR TR NL3 NL4 TV NL4 U1 TR NL6b NL4 TR 3a NL3 b )ffl 6 SH SH TR TR 1t NL4d NL4d, au �p ENLARGED UNIT TYPE A - LIGHTING ENLARGED UNIT TYPE A -POWER 1 1/4" =1'-01, A DS - 0 - a NL6a yam( TR DS M � NI-2 NL6a DS DS TR J NL6a NL6a NL4 TR TV SH DF NL4 TR 0 NL6e NL4d U1 TR NL6b a NL3 0 DS SH NL6e d69 TR TR e TR NL4 NL4d U4 GFI TP TR NL6d 4 NI-5 NL4 8 ENLARGED UNIT TYPE B - LIGHTING � ENLARGED UNIT TYPE B - POWER 1/4" =1'-0" 1/4" =1'-0" TR NL3 TR NL3 WP TR N L3=0 TR NI-7 TREF GFB NL1 TR GFI NI-2 TR GFI NL7 SH TR GFI NL3 TR NL3 ®2 SP/COD OSB SP/COD SV4 IE SB(LF) LF ENLARGED UNIT TYPE A - TECHNOLOGY �J 1/4" =1'-0" SV4 a❑ V02 LF� SP/COD SB(LF) ❑F ENLARGED UNIT TYPE B - TECHNOLOGY 1/4" =1'-0" SP/COD SB KEYED NOTES - a 1. LIGHTING FOR SPACE SHALL BE PROVIDED BY RESIDENT. Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 QIi NIG cox c DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778,23601 r-d@ringdu.coi RD Project Number: 218092.00 ryo, 0033339 s � Ne o o U O L -+-' L.0 �I— Co O >, C O C— (3.) C ) � N O W CU :�. Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - UNIT PLANS N N to In N O O N �I C- U Q Sheet Number: U Cn E300 t6 Q C SHEET NOTES - 1. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENTS POWER CIRCUITS PER NEC SECTION 210.12. �7, C91WXMIT SMITH H MYL OPMENT W z m O o% rn I O N WI �I U O W Cn U L 0 CU NI rn 0 00 c a) U 0 r) w 0 i a) Cn U n M co M N O O N U4 NL6d O DS NL6e e 69 d 09 0 DF NL6e ONI-13b b -69 6 3a 3a 0 DS NL6a 0 DS NL6a O DS Q DS NL6a NL6a a 1 ENLARGED UNIT TYPE ClLIGHTING O DS NL6a DS NL6a 0 0 DS NL6a a DS NL6a 3a 0 3a- 9 - 9 b 0 DF NL6e 0 DS NL6e U4 F1 NL6d u dtte DS ONL6c &9 c OU1 NI-13b 4 ENLARGED UNIT TYPE CZ - LIGHTING 114" =1'-0" tQDS DF 3a NL6a 0 NL6h DS 0 0 0 NL6h DS NL6e DF NL6e DS TR NL6a G U4 � GFI NL6d U4 NL5 DS DS NL6g e d 0 a O6a g h SH TR NL8d b -69 - 9 3a 4a -69 - 9 f ONI-15b ONI-6f a SH � TR NL8d ENLARGED UNIT TYPE C3 - LIGHTING 7 0" SH TR NL4d SH @-- TR NL4d TR 8NL4 TRF ® GFB NL1 TR GFI NL2 TR GFI NL7 TR NL3 TREF TR TR GFB GFI NL7 NL1 NL5 TR NL2 TR GFI NL2 TR GFI TR NL7 NL3 TR NL4 TR GFI NL3 =@ TR TR t2t= TV Nil Nil I NL3 TR TV NL4 ENLARGED UNIT TYPE C1- POWER TR NL7 TR NL2 TR NL-3 � 9T R NL4 TR TR T/ TR TV NL3 NR3 NL3 NL4 ENLARGED UNIT TYPE C2 - POWER 5 1/4" =1'-0" TRF ® GFB NL1 TR GFI NL2 TR GFI NL7 NL8 TR TV TR NL3 TV NL8 TR NL8 TR NL7 TR NL2 TR NL3 TR TR TR NL3 NL3 6 ENLARGED UNIT TYPE C3 - POWER 8 1 /4" =1'-0" TR TV NL4 TR GFI NL5 4 SH TR TR NL4 NL4d TR NL4 V02 OR VO 1 /C SV4 LF SP/COD 0 SB(LF) SP/COD 0 SB ENLARGED UNIT TYPE C1- TECHNOLOGY 3 114" =1'-0" V02 SV4 0 LF SP/COD ® SB SP/COD SB(LF) ENLARGED UNIT TYPE C2 - TECHNOLOGY -0" TR GFI 0 V01/C NL5 SH TR NL4d SH TR NL4d SP/COD SV4 ❑F SB(LF) LF Vol ❑F Vol /C 0 SB/COD 0 LF FF SP/COD SB(LF) 90ENLARGED UNIT TYPE C3 - TECHNOLOGY 1 /4" =1'-0" KEYED NOTES - a 1. ALL LIGHTING IN ROOM SHALL BE PROVIDED BY RESIDENT PER OWNERSHIP. 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com mm�`TFL--F1 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & w DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 I r-d@ringdu.cor RD Project Number: 218092.00 0 % l 11l l II/, �a�\QF GO N NFcT `Q %NCO Is Na, 0033339 I i � C O O U s.= O U) W O N— U� ® >, O N U ® w co U � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - UNIT PLANS a. U U Q Sheet Number: U N a E301co f w z m O ry n ry rn I 0 N wl FI U CD W 0 U �3a oul N L7a U1 NL7b H�>):� LV NL7U DF O N L7e 3aeg w,d b69 w-e U4 NL7d DS O N L-7e O nG VI N L8e DS O NL8e dea e ea U4 NL8d 4 ENLARGED UNIT TYPE MC-P - LIGHTING 1/4" = l'-0" GFI TRP 3a NL1 NL5 oul TR NL8a GFI NL5 ea 3a -ea b TR GFI TR NL2 TR TV Tv NL1 NL6 SH TR SH NL6h TR NL3h LV U1 t NL8U NL8b TR NL3 SH SH TR TR NL6h NL3h TR TR NL3 TR GFI NL6 1 TR NL44 TR NL3 u NL6 ENLARGED UNIT TYPE MC-P - POWER SV4 LF SP/COD 10 SB(LF) OR V01/C ENLARGED UNIT TYPE MC-P - TECHNOLOGY 3 1/4" =1'-0" u TRt 9 TR O DF U4 3a GFI NL1 NL5e NL5d NL2 eLr(LV � NL5UONI-5a d 0 DS TR 0 NL5e GFI V01/C NL1 3a b TR NL1 -6- f TR TR cu NL3 NR4 cu V11 V11 TR TR NL3h NL4h U1 U1 NL5f NL5b TR TR TV @-- TV NL3 NL4 SH SH TR TR TR TR NL3h 6NL3 NL48 NL4h e��d Ifl 14 NL6d ENLARGED UNIT TYPE MC-SP - LIGHTING 1/4" =1'-0" b 69 69 3a U1 NL6b c -6- DS O NL6c O O DS DF DS NL6e NL6e NL6c 3a XF EM-13U XS NL6 ED Q DS p NL6c DS NL6c O DS NL6c ENLARGED UNIT TYPE MC-SP - POWER S �F rq 0 SV2 SP/COD SB(LF) SP/COD 0 SB(LF) � �, ENLARGED UNIT TYPE MC-SP - TECHNOLOGY � _� 1/4" =1'-0" SHEET NOTES - 1. E.C. SHALL PROVIDE AFCI CIRCUIT BREAKERS FEEDING ALL ASSISTED LIVING AND MEMORY CARE RESIDENT APARTMENTS POWER CIRCUITS PER NEC SECTION 210.12. KEYED NOTES - a 1. TYPE "LV" SHALL BE VERTICALLY MOUNTED NEXT TO BATHROOM DOOR. CENTER OF FIXTURE SHALL BE MOUNTED 5'-6" AFF. 2. ALL NON -EMERGENCY LIGHTING IN ROOM SHALL BE PROVIDED BY RESIDENT PER OWNERSHIP. PP"TSUMMIT SMITH DEVELOPMENT 241 N Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD _J1 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 \��IIIIIIIJ���/ G 0 N N, s C/o d �. No.0033339 4 I � Z_—'- / 1' CU O O � U L O W U) O A CU i a L C) o w U -0 co O CU Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - UNIT PLANS N d- 71. co M N rn 0 N N ENLARGED UNIT TYPE C2 - WITH EGRESS - LIGHTING 1/4" =1'-0" C_ <Sheet Number: C_ U A cB E302 a� c d w z m ry rn I 0 N WI �I U C� W U 0 0 U 36" (T18" DID NL-96 N L-98 �11 DID EM-42 48" 48" EM-40 N L-96 =0 48" EM-40 ENLARGED PLAN - IT 1054 - TELECOM 114" =1'-01, 36" DID $118" N L-82 N L-80 A-A�- �� $11 DID EM-24 48" N L-80 48' 6EM-24 \, ENLARGED PLAN - IT 2043 - TELECOM 12 / 1l4" = l'-0" 72" NL--106 48" DID EM--38 36" DID N L-108 P OS-16 ELEV DS I, 2 ELEV Ia DS— �l OS-1 ECS E1 NL-85 N L-85 8 �\ ENLARGED PLAN - ELEV tC! 2U8U - tLtl: I KICAL 11 114" 18" �NL-106 48" =:@ EM-36 48" =@ EM-36 18" N L-106 @ ENLARGED PLAN - IT 1025 - TELECOM 5 114" =1'-0" 36" 18" DID NL-114 NL-116 48'� $$„ EM-22 DID EM-22 18 NL-114 48" NL-114 ENLARGED PLAN - IT ROOM 2012 - TELECOM 114" =1'-01, NL-104 NL 1-5 N L-104 NL-104 1-6 NL6 ENLARGED PLAN - ELEC 1022 - ELECTRICAL �114" =1'-0" l —2 aO F14�T ECS I ELEV I ELEV E1 I DS DS L-JL 6NL-116 tNLAKGtU PLAN - ELtV 2U16 - tLtC I KICAL 114" = 1'-011 48" (9-- NL-1 L-116 OS-14 NL OS LCP 2-3 2-1 2r,nC 48" NL-118 NH 18" � EM-16 18" NL-114 48', NL-114 N L-118 2-2 �A D D �� u 481, 36" EM-16 �NL-114 DID EM NL NL-116 2-1 2-4 -"'\ ENLARGED PLAN - ELEC 2086 & IT 2079- ELECTRICAL 1/4" =1'-0" 48" 18" 18" EM-20 NL-110 NL-110 @-- 48" 48" 36" DID NL-110 DID EM-20 NL-112 6 EM _� NL 1-1 n NL-114 1-4 NL L NL-114 NL-114 LCP 1-3 1MC 4�1� NH 1-2 ENLARGED PLAN - ELEC 1090 & IT 1091- ELECTRICAL 114" =1'-01, SHEET NOTES - � l -� AIM MIT �� 1. REFER TO LOW VOLTAGE AND DRAWINGS FOR FINAL ____ SMITH LOCATIONS AND MOUNTING HEIGHTS OF POWER P,31EV7LOPMENT RECEPTACLES WITHIN EACH WITHIN EACH TELECOMMUNICATIONS ROOM. 2. E.C. SHALL PROVIDE 4 INCH CONDUIT PENETRATIONS 241 N. BroadwaySuite 400 FROM THE CORRIDOR INTO EACH TELECOMMUNICATIONS Milwaukee, WI 53202 ROOM LOCATION. REFERENCE LOW VOLTAGE DOCUMENTS OS -1�E`LEV iNL-120 FOR EXACT QUANTITY AND LOCATIONS. Phone: 414-453-0110 ECS IELEV 3. E.C. SHALL PROVIDE CONDUIT PENETRATIONS FOR FLOOR Fax: ite: ww 12 Website: www.summitsmith.com E1 DS DS TO FLOOR PATHWAYS OF LOW VOLTAGE CABLING. REFERENCE LOW VOLTAGE DRAWINGS FOR FINAL ^ ^ fN^KIMI 11T [�17f'- ^I IA AITITV AK1D I Or'ATI^KIC- IVLI 14U J umj -J L H IiVIV L/UI 1 JILC, WUMIN 11 I i /'11Vv Lvli/'111v INO. �f 4. COORDINATE WITH LOW VOLTAGE DRAWINGS FOR OS-14 ADDITIONAL INFORMATION FOR PLYWOOD REQUIREMENTS 6 WITHIN EACH TELECOMMUNICATIONS ROOM LOCATION. [I[ CMMKI-H71DI-�--u D CONSTRUCTION SERVICES KEYED NOTES _a 889 E. Johnson Street EIVLAKGED PLAN - ELEV LU34 - ELECTRICAL 8 1. E.C. SHALL PROVIDE (1) 3 INCH CONDUIT FROM IT DMARC Fond Du Lac, WI 54936 11411=1'-0" TO THE ROOF FOR FUTURE INSTALLAITON OF EMERGENCY Phone: 920-924-2900 BI-DIERCTIONAL LIFE SAFETY ANTENNA, CONDUIT SHALL BE Fax: 920-924-2910 SEALED AT THE ROOF FOR FUTURE INSTALLATION. Website: www.cdsmith.com REFERENCE TS SERIES LOW VOLTAGE DRAWINGS FOR ADDITIONAL INFORMATION. 2. E.C. SHALL PROVIDE (1) 20A-1P, 120V DISCONNECT FOR ELEVATOR CAB LIGHTING AND FAN SHUT OFF. PROVIDE WIRING FROM DISCONNECT TO ELEVATOR CONTROLLER. 3. E.C. SHALL PROVIDE (1) 100A-3P, 480V HEAVY DUTY, LOCKABLE, FUSED DISCONNECT FOR ELEVATOR SHUT OFF. COORDINATE EXACT REQUIREMENTS WITH APPROVED ELEVATOR SPECIFICATIONS. 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 NL LCP Fax:414-359-3070 2-5 2AL RING & DUCHATEAU 174nn Wept ('.anitnl nr11;e - Rrnnkfield 1A11 58045 NL-112 NL-112 Phone: 414.778.17001 Fax: 414.778.23601 r-d@ringdu.cor RD Project Number: 218092,00 2-1 1 (1-2) LJ��},Y IJ F NL-112 HE OS e , No, 0033339 6�ENLARGED PLAN - ELEC 2004 - ELECTRICAL 0 NL-60qp OOS NL-60 DS EI EM T ATS ATS qS -ID LD OS NL-60 EM OS 1-2 LD GND pS OSH FACP NL-60 A 1-2 1-1 (INL-6 I RNL-58 PNL-58 LCP 1AL MAIN ELEC NH 1041 1-1 NL-58 NL 1-1 II I II II I ENLARGED PLAN - ELEC 1042 - ELECTRICAL 114" =1'-01, 36" DID N L-40 1 811 18" 48" NL-38 NL-38 DID 18" NL-38 24" AFF DID �N L-40 EM-32 48"=@ NL-40 =@ 24" 18" DID 48" NL-38 EM-32 DID LCP LL NL NL L-1 L-2 NL-3 NNL-36 O O L O W O �-1— C/) O N L O W co 0 CIO Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - ELEC & IT ROOMS lei �� ENLARGED PLAN - IT 0015 - TELECOM y15 j 114" =14" ENLARGED PLAN - IT 0018 - TELECOM 11 13 4" (�114 LARGED PLAN-ELEC 0017-ELECTRICAL ' =1'-0" U Sheet Number: U Cn E303 a R LL1 Z m O 0 ry rn I O CV LU H-I U CD LU U O t'u U ti LCi M CV O CV N KITCHEN EQUIPMENT SCHEDULE ITEM. SERVING VOLT PHASE LOAD FEED FROM OCPD BRANCH WIRING DISCONNECT SWITCH MOUNTING HEIGHT OPTIONS SEE NOTE KW AMP HP PANEL CIRCUIT BRANCH SIZE TYPE POLE NO. SIZE COND GRD SIZE FURN BY INST BY WIRED BY LOC. OPTIONS K14 NON-INSULTAED HEATED CABINET 120 1 16 NU1-K 1 N 20 CB 1 2 12 1 1/2" 12 - - - - - 50" AFF - 6 K15 MIXER 120 1 1 8.6 NU1-K 3 N 20 CB 1 2 12 1/2" 12 - - - - - 50' AFF 5 K19 SLICER 120 1 7 NU1-K 5 N 20 CB 1 2 12 1/2" 12 - - - - - 50" AFF 5 K20 FOOD PROCESSOR 120 1 7 NU1-K 7 N 20 CB 1 2 12 1/2" 12 - - - - - 50" AFF 6 K22 (1) CARRIER, FOOD 120 1 2 NU1-K 11 N 20 CB 1 2 12 1/2" 12 - - - - - 12" AFF 5 K22 (2) CARRIER, FOOD 120 1 2 NU1-K 11 N 20 CB 1 2 12 1/2" 12 - - - - - 12" AFF 5 K24 KETTLE, STEAM JACKETED 208 3 19.6 54.5 NU1-K 25,27,29 N 20 CB 3 3 12 1/2" 12 - - - - - 25" AFF 3 K25 CONVECTION, STEAMER 120 1 4 NU1-K 13 N 20 CB 1 2 12 1/2" 12 - - - - 25" AFF - 5 K27 PORTABLE FOOD WARMERS 120 1 4.4 NU1-K 15 N 20 CB 1 2 12 1/2" 12 - - - - - 25" AFF - 5 K29 RANGE, RESTAURANT GAS 120 1 3.4 NU1-K 17 N 20 CB 1 2 12 1/2" 12 - - - - - 19" AFF - 5 K31.1 FIRE SUPPRESSION CABINET 120 1 NU1-K 26 EM 20 CB 1 2 12 1/2" 12 - - - - - - - 8 K32 CONVECTION OVEN, GAS, DOUBLE 120 1 9.8 NU1-K 19 N 20 CB 1 2 12 1/2" 12 - - - - 25" AFF 11 5 K33 REFRIGERATOR, EQUIPMENT STAND 120 1 2 OS/1-2 1 OS 20 CB 1 2 12 1/2" 12 - - - - 25" AFF - 5 K35 REFRIGERATOR, U/C DRAWER 120 1 5.1 - N 20 CB 1 2 12 1/2" 12 - - - - - 1,5 K36 TOASTER, CONVEYOR 120 1 1.8 15 - - N 20 CB 1 2 12 1/2" 12 - - - - - 1,5 K37 (1) POS PRINTER 120 1 1 NU1-K 21 N 20 CB 1 2 12 1/2" 12 - - - - - - 4,5 K37 (2) POS PRINTER 120 1 1 NU1-K 21 N 20 CB 1 2 12 1/2" 12 - - - - - - 4,5 K37.1 POS MONITOR 120 1 1 NU1-K 21 N 20 CB 1 2 12 1/2" 12 - - - - - - - 45 K38 OVEN MICROWAVE 120 1 1.5 14 - - N 20 CB 1 2 12 1/2" 12 - - - - - - - 15 K40 FREEZER, U/C DRAWERS 120 1 2.6 NU1-K 23 N 20 CB 1 2 12 1/2" 12 - - - - - - 15 K41 CHEF'S TABLE 208 3 125 MDP/L SD N SD CB 2 SD SD SD SD 12" AFF 3 2 K42 HOT WELLS, DROP IN 208 3 4.82 15.8 NU1-K - N 20 CB 3 3 12 1/2" 12 - - - - - 3 3 K43 FOOD WARMER 208 1 6.7 - N 20 CB 1 2 12 1/2" 12 - - - - - 3 3 K44 DROP -IN PLATE DISPENSER, HEATED 120 1 3.8 - - N 20 CB 1 2 12 1/2" 12 - - - - - - 15 K45 REFRIGERATOR, SAND/SALAD PREP 120 1 7.2 - - N 20 CB 1 2 12 1/2" 12 - - - - - - 1,5 K46 REFIRGERATOR, PASS THRU 120 1 4.2 OS/1-2 3 N 20 CB 1 2 12 1/2" 12 - - - - - - 1,5 K48 ICE MAKER 208 1 11.2 OS/1-2 5 OS 20 CB 1 2 12 1/2" 12 - - - - 60" AFF 3 K54 WASHWARE, RACK CONVEYOR 208 3 48.8 NU1-K 30,32,34 N 20 CB 3 3 12 1/2" 12 EC EC EC NU - 12" AFF 3 4 K54.1 BOOSTER HEATER 208 3 75 MDP/L SD N SD CB SD SD SD SD SD EC EC EC NU - 12" AFF 3 4 K54.2 WATER TREATMENT SYSTEM 120 1 2 NU1-K 2 N 20 CB 1 2 12 1/2" 12 - - - - 12" AFF - 4,5 K56 GARBBAGE DISPOSAL 208 3 2 NU1-K 12,14,16 N 20 CB 3 3 12 1/2" 12 - - - - - 24" AFF 3 K61 GARBBAGE DISPOSAL 208 3 3.3 NU1-K 12,14,16 N 20 CB 3 3 12 1/2" 12 - - - - - 12" AFF 3 K63 REFRIGERATOR, ROLL IN, GLASS DOOR 120 1 6 OS/1-2 2 OS 20 CB 1 2 12 1/2" 12 - - - - - 67" AFF 5 K66 REFRIGERATOR, U/C COMPACT 120 1 4 OS/1-2 4 OS 20 CB 1 2 12 1/2" 12 - - - - 25" AFF - 5 K67 TEA BREWER 120 1 14.4 NU1-K 8 N 20 CB 1 2 12 1/2" 12 - - - - 50" AFF - 4,5 K68 COFFEE BREWER 120 1 14.4 NU1-K 10 N 20 CB 1 2 12 1/2" 12 - - - - - 50" AFF - 4,5 K69 JUICE DISPENSER 120 1 6 NU1-K 18 N 20 CB 1 2 12 1/2" 12 - - - - - 50" AFF - 4,5 K74 ICE CREAM DIPPING CABINET 120 1 7.5 NU1-K 36 N 20 CB 1 2 12 1/2" 12 - - - - - 12" AFF - 5 K76 DECORATIVE CARVING STATION 120 1 5 NU1-K 22 N 20 CB 1 2 12 1/2" 12 - - - - - 50" AFF - 5 K77 (1) DROP IN FOOD WARMER 120 1 6 NU1-K 24 N 20 CB 1 2 12 1/2" 12 - - - - - 25" AFF - 5 K77 (2) DROP IN FOOD WARMER 120 1 6 NU1-K 26 N 20 CB 1 2 12 1/2" 12 - - - - - 25" AFF - 5 K78 HEATED DISH DISPENSER, DROP -IN 120 1 3.8 NU1-K 28 N 20 CB 1 2 12 1/2" 12 - - - - - 12" AFF - 5 KCD WALK IN COOLER DOOR 120 1 5 OS/1-2 54 OS 20 CB 1 2 12 1/2" 12 - - - - - 9 KCCU WALK IN COOLER CONDENSING UNIT 208 1 7.2 OS/1-2 51,53 OS 15 F 2 2 12 1/2" 12 EC EC EC NU - - - 8 KCL WALK IN COOLER LIGHTS 120 1 1 OS/1-2 56 OS 20 CB 1 2 12 1/2" 12 - - - - - - 9 KFD WALK IN FREEZER DOOR 120 1 3.1 OS/1-2 56 OS 20 CB 1 2 12 1/2" 12 - - - - - - 9 KFCU WALK IN FREEZER CONDENSING UNIT 208 1 15.1 OS/1-2 55,57 OS 30 F 2 2 EC EC EC NU - - - 8 KCL WALK IN FREEZER LIGHTS 120 1 1 OS/1-2 56 OS 20 CB 1 2 12 1/2" 12 - - - - - - - 9 KRFL ROOF TOP FAN & LIGHTS 120 1 3 OS/1-2 59 OS 20 CB 1 2 12 1/2" 12 - - - - - - 8 KCCUF KITCHEN COOLER COOLING UNIT FAN 120 1 1.6 OS/1-2 61 OS 20 CB 1 2 12 1/2" 12 EC EC EC NU - - - 8 KFCUF KITCHEN FREEZER COOLING UNIT FAN 208 1 0.5 OS/1-2 63,65 OS 20 CB 2 2 12 1/2" 12 EC EC EC NU - - - 8 KFCUH KITCHEN FREEZER COOLING UNIT HEATER 208 1 4.9 OS/1-2 63,65 OS 20 CB 2 2 12 1/2" 12 EC EC EC NU - - - 8 KEF1 KITCHEN EXHAUST FAN (K31) 480 3 10.1 NH/1-1 37,39,41 N 20 CB 1 2 12 1/2" 12 EC EC EC NU - - - 8 KEF2 KITCHEN EXHAUST FAN (K55) 120 1 5.6 NU1K 45 N 20 CB 1 2 12 1/2" 12 EC EC EC NU - - - 8 KEF3 KITCHEN EXHAUST FAN (El 1) 120 1 5.6 NU1K 41 N 20 CB 1 2 12 1/2" 12 EC EC EC NU - - - 8 KMUA-1 MAKE UP AIR UNIT 480 3 MSB SFP N SFP CB SFP SFP SFP SFP SFP EC EC EC NU - - 8 KCU-1 KITCHEN CONDENSING UNIT (MUA-1) 480 3 10.5 NH/1-1 36,38,40 N 20 F 3 3 12 1/2" 12 EC EC EC NU - - - 8 KCU-2 KITCHEN CONDENSING UNIT (MUA-1) 480 3 10.5 NH/1-1 42,44,46 N 20 F 3 3 12 1/2" 12 EC EC EC NU - - - 8 KSF-1 KITCHEN SUPPLY FAN (MUA-1) 480 3 6.8 1 5 NH/1-1 43,45,47 N 20 CB 3 3 12 1/2" 12 EC EC EC NU - 8 ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD LS = LIFE SAFETY BRANCH S = AMPERE RATED SWITCH MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF CR = CRITICAL CARE BRANCH F = AMPERE RATED FUSES CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT EQ = EQUIPMENT SYSTEM OCPD = OVERCURRENT PROTECTIVE DEVICE RVS = REDUCED VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH EM = EMERGENCY SYSTEM EC = ELECTRICAL CONTRACTOR 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS ES = ESSENTIAL SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONE -LINE DIAGRAM OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON -FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER 11 = TWO POINT CONNECTION 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNT 3 = DIRECT CONNECTION 6 = WEATHER PROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNT KITCHEN EQUIPMENT SCHEDULE NOTES: 1. E.C. SHALL PROVIDE CONNECTION TO PRE -WIRED RECEPTACLE ON CHEF'S TABLE (K41). 2. E.C. SHALL PROVIDE SINGLE POINT, DIRECT CONNECTION AT ELECTRICAL PANEL ON CHEF'S TABLE. PROVIDE CONDUIT STUB UP FROM FLOOR AT POINT OF CONNECTION. 3. E.C. SHALL PROVIDE FINAL CONNECTION TO PRE -WIRED EQUIPMENT ON CHEF'S TABLE. EQUIPMENT FED FROM CHEF'S TABLE ELECTRICAL PANEL. 4. E.C. SHALL VERIFY ELECTRICAL REQUIREMENTS FOR OWNER PROVIDED EQUIPMENT PRIOR TO INSTALLATION. 5. E.C. SHALL PROVIDE NEMA 5-15P TYPE RECEPTACLE. 6. E.C. SHALL PROVIDE NEMA 5-20P TYPE RECEPTACLE 7. EC TO WIRE PER MANUFACTURER'S INSTALLATION MANUAL. REFER TO CAPTIVEAIRE DRAWINGS FOR ADDITIONAL INFORMATION. 8. EC TO INTERCONNECT WITH MICRO SWITCH AT FIRE SUPPRESION CABINET AND SHUNT TRIP BREAKERS FOR ALL EQUIPMENT UNDER KITCHEN HOOD. 9. E.C. SHALL PROVIDE SINGLE POINT CONNECTION AT THE DOOR FOR LIGHTS, ALARMS AND HEAT ACCESSORIES. REFERENCE FS500 SERIES PLANS FOR ADDITIONAL INFORMATION. EXHIBITION KITCHEN EQUIPMENT SCHEDULE ITEM. SERVING VOLT PHASE LOAD FEED FROM OCPD BRANCH WIRING DISCONNECT SWITCH MOUNTING HEIGHT OPTIONS SEE NOTE KW AMP HP PANEL CIRCUIT BRANCH SIZE TYPE POLE NO. SIZE COND GRD SIZE FURN BY INST BY WIRED BY LOC. OPTIONS E1 TOASTER 120 1 2.6 15 NU1-K 31 N 20 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 E3 DROP -IN PLATE DISPENSER, HEATED 120 1 - 3.8 - NU1-K 33 N 15 CB 1 2 12 3/4 12 - - - - - - - 5 E4 INDUCTION RANGE, COUNTERTOP 120 1 1.8 15 - NU1-K 35 N 20 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 E5 (1) GLASS SHELF, HEATED 120 1 - 2.5 NU1-K 37 N 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 E5 (2) GLASS SHELF, HEATED 120 1 - 2.5 NU1-K 37 N 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 E6 UNDERCOUNTER REFRIGERATOR 120 1 - 3.2 OS/1-2 9 OS 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 E10 PIZZA OVEN 120 1 - 2 NU1-K 39 N 20 CB 1 2 12 3/4 12 - - - - - 25" AFF 3 Ell EXHAUST HOOD 120 1 - 5.6 NU1-K 41 N 20 CB 1 2 12 3/4 12 EC EC EC NU 4 - 3 2 El l.1 FIRE SUPPRESSION 120 1 - - - EM SFP EM 20 CB 1 2 12 3/4 12 EC EC EC NU 4 - 3 3 E12 POS PRINTER 120 1 - - NU1-K 43 N 20 CB 1 2 12 3/4 12 - - - - - - 4 ABBREVIATIONS: N = NORMAL BRANCH LS = LIFE SAFETY BRANCH OS = OPTIONAL STANDBY EQ = EQUIPMENT SYSTEM EM = EMERGENCY SYSTEM ES = ESSENTIAL SYSTEM CB S F OCPD EC FSEC = AMPERE RATED CIRCUIT BREAKER = AMPERE RATED SWITCH = AMPERE RATED FUSES = OVERCURRENT PROTECTIVE DEVICE = ELECTRICAL CONTRACTOR = FOOD SERVICE EQUIP. CONTRACTOR MAN MAG CS RVS 2SP VFD = MANUAL CONTROLLER = MAGNETIC CONTROLLER = COMBINATION CONTROLLER = REDUCED VOLTAGE CONTROLLER = 2 SPEED MAGNETIC CONTROLLER = VARIABLE FREQUENCY DRIVE IU NU OU SFP SFS SD = IN UNIT = NEAR UNIT = ON UNIT = SEE FLOOR PLANS = SEE FOOD SERVICE PLANS = SEE ONE -LINE DIAGRAM BOL WP FD LMRS = BUILT-IN OVERLOAD = WEATHER PROOF = FUSIBLE DISCONNECT = LOCKABLE MOTOR RATED SWITCH OPTIONS: 1 = SINGLE RECEPTACLE 2 = DUPLEX RECEPTACLE 3 = DIRECT CONNECTION 4 5 6 = NON -FUSIBLE DISCONNECT = FUSIBLE DISCONNECT = WEATHER PROOF 7 8 9 = LOCKABLE = CONCEALED = TOGGLE SWITCH 10 11 12 =VERIFY WITH MANUFACTURER = SURFACE MOUNT = FLUSH MOUNT EXHIBITION KITCHEN EQUIPMENT SCHEDULE NOTES: 1. E.C. SHALL PROVIDE NEMA 5-15P TYPE RECEPTACLE. 2. EC TO WIRE PER MANUFACTURER'S INSTALLATION MANUAL. REFER TO CAPTIVEAIRE DRAWINGS FOR ADDITIONAL INFORMATION. 3. EC TO INTERCONNECT WITH MICRO SWITCH AT FIRE SUPPRESION CABINET AND SHUNT TRIP BREAKERS FOR ALL EQUIPMENT UNDER KITCHEN HOOD. 4. EC TO VERIFY ELECTRICAL REQUIREMENTS WITH OWNER/OPERATOR PRIOR TO INSTALLATION. 5. E.C. SHALL PROVIDE NEMA L5-15R TWIST LOCK TYPE RECEPTACLE. GFI NL-20 E12 GFB ® N L-43 a 25" AFF E1 ® GFI NL-31 GFI NL-20 DED GFI NL-40 ® 12" AFF K22 DED GFI GFI NL-11 N L-42 *12" AFF K22 GFI N L-11 GFI N L-9 E10 NL-39 25" AFF E6 GFB OS-9 SHEET NOTES - A. REFERENCE FOOD SERVICE AND FOOD SERVICE VENDOR DRAWINGS FOR EXACT INSTALLATION REQUIREMENTS FOR APPROVED KITCHEN AND BISTRO EQUIPMENT. B. NORMAL SYSTEMS 480Y/277V'NH' BRANCH POWER SHALL BE FED FROM PANEL NH/1-1, UNLESS NOTED OTHERWISE. C. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1K, UNLESS NOTED OTHERWISE. D. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS NOTED GFI OTHERWISE. NL NL-38 E. ESSENTIAL SYSTEMS 208Y/120V BRANCH POWER SHALL BE 1-K FED FROM PANEL EM/1-2, UNLESS NOTED OTHERWISE. 8 46" AFF GFI NL-38 10 ®K31.1 9 EM-28CU GFI NL-38 ®25" AFF K24 NL-25,27,29 25" AFF ® K25 NL-13 50" AFF 25" AFF K14 ® ® K27 NL-1 NL-15 50" AFF 19" AFF K20 11my K29 NL-7 NL-17 GFI NL-9 50" AFF 25" AFF K19 ® K33 NL-5 ® OS-1 GFI NL-9 50" AFF tT 25'nAFF K15 ® `e' KOL NL-3 NL19 ® ® E11 NL-41 K11.0 �® EM-20 GFI NL-20 E3 m (& L-33 25" AFF 25" AFF 25" AFF GFB E4 E5 E5 GFB GFB GFB N L-35 N L-37 N L-37 60" AFF ® K48 OS-5 K31 ® N L-46 GFI N L-44 25" AFF K63 OS-2 KCCU m OS-51,53 KCD ® KCCUF OS-54 OS-61 KCL K46 ® OS-3 WALK-IN COOLER 1035A KFD OS-56 KFCUF ® OS-63,65 KFL ® KFCUH OS-63,65 (&KFCU OS-55,57 GFI El:) OS-7 K45 EDt ®KRFL ® WP OS-59 ® K40 K44 ® N L-23 ® K41 K42 ® K43 ® K38 ©®K37 NL-21 ® K36 K35 12" AFF K78 NL-28 50" AFF 25" AFF ® K76 NL 24 NL-22 25" AFF K37 K77 NL-6 ® NL-26 K37.1 NL-6 25" AFF K66 OS-4 GFI NL-4 12" AFF K54.1 ® 12" AFF MDP/L K54 NL-30,32,34 ® K55 12 AFF ®K54.2 NL-2 � GFI NL-4 ® 24" AFF K56 -6 GFI GFI NL-4 12" AFF K74 OS-66 ENLARGED PLAN - FIRST FLOOR KITCHEN & EXPO. KITCHEN - POWER 1 /4" =1'-0" 9GFI NL-4 12"AFFm K61 'G N L-6 qPGFI N L-44 50" AFF 50" AFF 50" AFF K69 K67 K68 NL-18* N® ®L-10 KEYED NOTES - Q 1. REFERENCE EQUIPMENT SCHEDULE AND FOOD SERVICE DRAWINGS FOR EQUIPMENT FED FROM CHEF'S TABLE ELECTRICAL PANEL. 2. PROVIDE RECEPTACLE FOR HEAT TAPE CONNECTION. REFERENCE FOOD SERVICE VENDOR DRAWINGS FOR ADDITIONAL INFORMATION. 3. E.C. SHALL PROVIDE SWITCHING TO CONTROL ROOFTOP FAN AND LIGHTS. 4. E.C. SHALL ROUGH -IN DOUBLE GANG BOX FOR EXHAUST HOOD ROOFTOP FAN CONTROLS. PROVIDE CONDUIT RACEWAY BETWEEN CONTROLS AND ELECTRICAL BOX. 5. E.C. SHALL PROVIDE POWER CONNECTION TO EXHAUST HOOD REMOTE FIRE SUPPRESSION SYSTEM. ELECTRICAL CABINETS SHALL BE INSTALLED NEAR CEILING. 6. RECEPTACLE AND DATA OUTLET SHALL BE MOUNTED TO UNDERSIDE OF CHEF'S TABLE UPPER SHELVING. PROVIDE (2) 1" CONDUITS, BENEATH FLOOR SLAB TO NEAREST FULL HEIGHT WALL FOR CABLE ROUTING. CONDUIT SHALL STUB UP FROM BENEATH FLOOR SLAB, NEAR LEG OF CHEF'S TABLE. REFERENCE LOW VOLTAGE AND FOOD SERVICE PLANS FOR CABLE ROUTING INTENT THROUGH THE CHEF'S TABLE. 7. E.C. SHALL PROVIDE RECEPTACLE AND DATA OUTLET AT SHELF BELOW COUNTER FOR OWNER PROVIDED POINT OF SALE PRINTER EQUIPMENT. COORDINATE EXACT MOUNTING HEIGHT AND INSTALLATION DETAILS WITH FOOD SERVICE CONTRACTOR. 8. E.C. SHALL PROVIDE STANDARD OCTAGON BOX WITH 1/2" CONDUIT TO ACCESSIBLE CEILING FOR MANUAL FIRE PULL STATION. REFERENCE DETAIL ON SHEET E520 FOR ADDITIONAL INFORMATION. COORDINATE INSTALLATION REQUIREMENTS WITH APPROVED VENDOR. 9. E.C. SHALL BE RESPONSIBLE FOR CONNECTION TO HOOD ELECTRICAL PANEL. E.C. SHALL BE RESPONSIBLE FOR ALL CONNECTIONS FROM HOOD ELECTRICAL PANEL TO WIRING CONNECTION FROM THE HOOD TO THE EXHAUST FANS AND ANSUL SYSTEM. 10. E.C. SHALL PROVIDE SHUNT TRIP TYPE BREAKER TO SHUT OFF COOKING EQUIPMENT. MAKE UP AIR UNIT LIGHTS AND FAN AND SHALL BE CVNIVEC T ED 1 V T HE BUILDIIVG FIRE ALARM SYSTEM FOR MONTIORING. "SUMMIT SMITH DEVELOPMENT 2d1 AI Rrr%nf%A/O\/ Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 11 CD 93M�7a CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & 6� DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360I r-d@ringdu.col RD Project Number: 218092.00 � `,.QF pPHER C , t �, No. 0033339 [V�` �, ` CQ O O U O `W W L� to O Cn C- a L L N O LU U -0 C-0 o CU Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - KITCHEN AND EXPO. KITCHEN - 'POWER lA U N U Q Sheet Number: C_ U !N ca E304 .�c c d 0 "SUMMIT SMITH DEVELOPMENT BISTRO EQUIPMENT SCHEDULE BASED ON DRAWINGS PROVIDED ON 10-12-2017 ITEM. SERVING VOLT PHASE LOAD FEED FROM OCPD BRANCH WIRING DISCONNECT SWITCH MOUNTING HEIGHT OPTIONS SEE NOTE KW AMP HP PANEL CIRCUIT BRANCH SIZE TYPE POLE NO. SIZE COND GRD SIZE FURN BY INST BY WIRED BY LOC. OPTIONS B5 REFRIGERATOR/FREEZER, DUAL TEMP 120 1 - 6 - OS/1-2 6 OS 15 CB 1 2 12 3/4 12 - - - - - 50" AFF - 1 B7 SOFT SERVE 208 1 12 OS/1-2 58 OS 20 CB 1 2 12 3/4 12 25" AFF 1 B8 DROP IN FOOD WARMER 120 1 - 6 - NL/1-5 81 N 15 CB 1 2 12 3/4 12 - - - - - 25" AFF 1 B10 BLENDER, BEVERAGE 120 1 - 7 - NU1-5 83 N 15 CB 1 2 12 3/4 12 - - - - - 46" AFF - 1 B11 TOASTER, SLOT TYPE 120 1 2.6 15 - NU1-5 85 N 20 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 B12 INDUCTION RANGE, COUNTERTOP 120 1 1.8 15 - NL/1-5 87 N 20 CB 1 1 2 12 3/4 12 - - - - - 50" AFF - 1 B13 HEATED GLASS SHELF 120 1 - 2.5 - NU1-5 89 N 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 B14 GOURMET COFFEE MAKER 120 1 - 10 - NU1-5 91 N 20 CB 1 2 12 3/4 12 - - - - - 46" AFF - 2 B15 REFRIGERATOR, UNDERCOUNTER, COMPACT 120 1 - 3.2 - OS/1-2 8 OS 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 B16 OVEN, RAPID COOK & MICROWAVE 208 1 4.5 20 - NU1-5 95 N 25 CB 2 2 10 3/4 10 - - - - - 46" AFF - 3 B17 ICE MAKER, UNDERCOUNTER 120 1 - 4.1 - OS/1-2 10 OS 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 B18 REFRIGERATOR, UNDERCOUNTER, COMPACT 120 1 - 4 - OS/1-2 10 OS 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 B19 FREEZER, UNDERCOUNTER COMPACT 120 1 - 5.8 - OS/1-2 12 OS 15 CB 1 2 12 3/4 12 - - - - - 12" AFF - 1 B20 REFRIGERATED SELF SERVICE CASE 120 1 - 12 - OS/1-2 14 OS 20 CB 1 2 12 3/4 12 - - - - - 12" AFF - 1 B21 POS 120 1 - - - NU1-5 97 N 20 CB 1 2 12 3/4 12 - - - - - - 2 ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD LS = LIFE SAFETY BRANCH S = AMPERE RATED SWITCH MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF CR = CRITICAL CARE BRANCH F = AMPERE RATED FUSES CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT OS = OPTIONAL STANDBY OCPD = OVERCURRENT PROTECTIVE DEVICE RVS = REDUCED VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH EM = EMERGENCY SYSTEM EC = ELECTRICAL CONTRACTOR 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS ES = ESSENTIAL SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONE -LINE DIAGRAM OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON -FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER 13 = DOUBLE DUPLEX RECEPTACLE 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNT 3 = DIRECT CONNECTION 6 = WEATHER PROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNT BISTRO EQUIPMENT SCHEDULE NOTES: 1. E.C. SHALL PROVIDE NEMA 5-15R TYPE RECEPTACLE. 2. EQUIPMENT PROVIDED BY OWNER. E.C. SHALL CONFIRM ELECTRICAL REQUIREMENTS OF APPROVED EQUIPMENT PRIOR TO INSTALLATION. 3. E.C. SHALL PROVIDE NEMA 6-20R TYPE RECEPTACLE. LOUNGE EQUIPMENT SCHEDULE LOAD FEED FROM OCPD BRANCH WIRING DISCONNECT SWITCH SEE ITEM. SERVING VOLT PHASE MOUNTING OPTIONS NOTE KW AMP HP PANEL CIRCUIT BRANCH SIZE TYPE POLE NO. SIZE COND GRD FURN INST WIRED LOC. OPTIONS SIZE BY BY BY HEIGHT L3 ICE MAKER, UNDERCOUNTER 120 1 - 5.3 OS/1-2 11 OS 15 CB 1 2 12 314 12 - - - - 25" AFF - 1 L4 REFRIGERATOR, BEVERAGE, UNDERCOUNTER 120 1 - 2 - OS/1-2 13 OS 15 CB 1 2 12 3/4 12 - - - - 12" AFF - 1 L6 REFRIGERATOR, UNDERCOUNTER, COMPACT 120 1 - 4 - OS/1-2 13 OS 15 CB 1 2 12 3/4 12 - - - - 25" AFF - 1 L7 POS 120 1 - - - NL/1-6 7 N 20 CB 1 2 12 3/4 12 - - - - - - 1,2 L9 UNDERCOUNTER DISHWASHER 208 1 - 45 - NU1-6 39,41 N 60 CB 1 2 6 1" 10 EC EC EC NU 4 12" AFF 3 1,2 ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD LS = LIFE SAFETY BRANCH S = AMPERE RATED SWITCH MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF OS = OPTIONAL STANDBY F = AMPERE RATED FUSES CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT EQ = EQUIPMENT SYSTEM OCPD = OVERCURRENT PROTECTIVE DEVICE RVS = REDUCED VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH EM = EMERGENCY SYSTEM EC = ELECTRICAL CONTRACTOR 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS ES = ESSENTIAL SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONE -LINE DIAGRAM OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON -FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER 13 = DOUBLE DUPLEX RECEPTACLE 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNT 3 = DIRECT CONNECTION 6 = WEATHER PROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNT LOUNGE EQUIPMENT SCHEDULE NOTES: 1. E.C. SHALL PROVIDE NEMA 5-15R TYPE RECEPTACLE. 2. EC TO VERIFY ELECTRICAL REQUIREMENTS WITH OWNER/OPERATOR PRIOR TO INSTALLATION. R Lu Z m 0 �I 0 NI LU 0 LU 0 ZD r � u K EDt B21 12" AFF 12" AFF 25" AFF 25" AFF NL-97 B20 B19 B18 B17 OS-14 OS-12 GFB GFB US-1 V V S-1 V 25" AFF 46 AFF B11 25" AF B10 GFI B13 GFI NL-85 GFB NL-83 * NL-89 22 NL-1109 25" AFF 50"AFF B8 B12 GFB GFI N L-81 N L-87 50" AFF B5 OS-6 F 25" AFF 46" AFF B15 B14 GFB GFB OS- NL-91 25" AFF B16 25"AFF B7 GFB 58,60 GFI NL-1 10 ENLARGED PLAN - FIRST FLOOR BISTRO - POWER 1/4" = 1'-0" DETAIL NOTES - GFB uu'N!9' NL-93 N L-11 U A. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1-5, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS OTHERWISE NOTED. KEYED NOTES - Q 1. KEY OPERATED LOCK OUT SWITCH SHALL SHALL BE PROVIDED TO CONTROL ALL EQUIPMENT EXCEPT THE REFRIGERATOR, ICE AND BEVERAGE MACHINE. KEY TO BE REMOVABLE IN THE OFF POSITION ONLY. 2. VERIFY ELECTRICAL REQUIREMENTS WITH OWNERS APPROVED VENDOR. 3. E.C. SHALL PROVIDE RECEPTACLE AND DATA OUTLET, MOUNTED HORIZONTALLY WITHIN BACKSPLASH. CONFIRM EXACT MOUNTING HEIGHT WITH LOW VOLTAGE DRAWINGS. L7 1 2 ® NL-37 25" AFF ® L6 OS-13 12" AFF GFB NL-39,41 ENLARGED PLAN - FIRST FLOOR LOUNGE KITCHEN - POWER 1/4" =1' 0" DETAIL NOTES - A. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1-6, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS OTHERWISE NOTED. KEYED NOTES - Q 1. VERIFY ELECTRICAL REQUIREMENTS WITH OWNER'S APPROVED MANUFACTURER PRIOR TO INSTALLATION. 2. E.C. SHALL INSTALL RECEPTACLE AND DATA OUTLET AT 38" AFF, HORIZONTAL MOUNTING WITHIN BACKSPLASH. COORDINATE EXACT LOCATION WITH FOOD SERVICE CONTRACTOR. 3. DUPLEX RECEPTACLE SHALL BE FOR OWNER PROVIDED TRIVIA TV CHARGING STATION. COORDINATE EXACT LOCATION WITH LOW VOLTAGE DRAWINGS PRIOR TO INSTALLATION. 44" AFF GFI N L-43 25" AFF L3 GFB OS-11 60" AFF TV N L-43 12" AFF L4 GFB OS-13 N L-43 241 N, Brnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.cor RD Project Number: 218092.00 cO N N c-0 co .-6 '. No. 0033339 r r r ` O CO U O S� � W 0 ^O W C M a� a) O W 4-; -0 � r O C a = � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - LOUNGE & BISTRO - POWER J J U N 00 M N O N N U ¢Sheet Number: U ca E305 Y C 25"AFF B7 GFB 58,60 GFI NL-1 10 ENLARGED PLAN - FIRST FLOOR BISTRO - POWER 1/4" = 1'-0" DETAIL NOTES - GFB uu'N!9' NL-93 N L-11 U A. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1-5, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS OTHERWISE NOTED. KEYED NOTES - Q 1. KEY OPERATED LOCK OUT SWITCH SHALL SHALL BE PROVIDED TO CONTROL ALL EQUIPMENT EXCEPT THE REFRIGERATOR, ICE AND BEVERAGE MACHINE. KEY TO BE REMOVABLE IN THE OFF POSITION ONLY. 2. VERIFY ELECTRICAL REQUIREMENTS WITH OWNERS APPROVED VENDOR. 3. E.C. SHALL PROVIDE RECEPTACLE AND DATA OUTLET, MOUNTED HORIZONTALLY WITHIN BACKSPLASH. CONFIRM EXACT MOUNTING HEIGHT WITH LOW VOLTAGE DRAWINGS. L7 1 2 ® NL-37 25" AFF ® L6 OS-13 12" AFF GFB NL-39,41 ENLARGED PLAN - FIRST FLOOR LOUNGE KITCHEN - POWER 1/4" =1' 0" DETAIL NOTES - A. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1-6, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS OTHERWISE NOTED. KEYED NOTES - Q 1. VERIFY ELECTRICAL REQUIREMENTS WITH OWNER'S APPROVED MANUFACTURER PRIOR TO INSTALLATION. 2. E.C. SHALL INSTALL RECEPTACLE AND DATA OUTLET AT 38" AFF, HORIZONTAL MOUNTING WITHIN BACKSPLASH. COORDINATE EXACT LOCATION WITH FOOD SERVICE CONTRACTOR. 3. DUPLEX RECEPTACLE SHALL BE FOR OWNER PROVIDED TRIVIA TV CHARGING STATION. COORDINATE EXACT LOCATION WITH LOW VOLTAGE DRAWINGS PRIOR TO INSTALLATION. 44" AFF GFI N L-43 25" AFF L3 GFB OS-11 60" AFF TV N L-43 12" AFF L4 GFB OS-13 N L-43 241 N, Brnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.cor RD Project Number: 218092.00 cO N N c-0 co .-6 '. No. 0033339 r r r ` O CO U O S� � W 0 ^O W C M a� a) O W 4-; -0 � r O C a = � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - LOUNGE & BISTRO - POWER J J U N 00 M N O N N U ¢Sheet Number: U ca E305 Y C A. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1-5, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS OTHERWISE NOTED. KEYED NOTES - Q 1. KEY OPERATED LOCK OUT SWITCH SHALL SHALL BE PROVIDED TO CONTROL ALL EQUIPMENT EXCEPT THE REFRIGERATOR, ICE AND BEVERAGE MACHINE. KEY TO BE REMOVABLE IN THE OFF POSITION ONLY. 2. VERIFY ELECTRICAL REQUIREMENTS WITH OWNERS APPROVED VENDOR. 3. E.C. SHALL PROVIDE RECEPTACLE AND DATA OUTLET, MOUNTED HORIZONTALLY WITHIN BACKSPLASH. CONFIRM EXACT MOUNTING HEIGHT WITH LOW VOLTAGE DRAWINGS. L7 1 2 ® NL-37 25" AFF ® L6 OS-13 12" AFF GFB NL-39,41 ENLARGED PLAN - FIRST FLOOR LOUNGE KITCHEN - POWER 1/4" =1' 0" DETAIL NOTES - A. NORMAL SYSTEMS 208Y/120V "NL" BRANCH POWER SHALL BE FED FROM PANEL NL/1-6, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OS" BRANCH POWER SHALL BE FED FROM PANEL OS/1-2, UNLESS OTHERWISE NOTED. KEYED NOTES - Q 1. VERIFY ELECTRICAL REQUIREMENTS WITH OWNER'S APPROVED MANUFACTURER PRIOR TO INSTALLATION. 2. E.C. SHALL INSTALL RECEPTACLE AND DATA OUTLET AT 38" AFF, HORIZONTAL MOUNTING WITHIN BACKSPLASH. COORDINATE EXACT LOCATION WITH FOOD SERVICE CONTRACTOR. 3. DUPLEX RECEPTACLE SHALL BE FOR OWNER PROVIDED TRIVIA TV CHARGING STATION. COORDINATE EXACT LOCATION WITH LOW VOLTAGE DRAWINGS PRIOR TO INSTALLATION. 44" AFF GFI N L-43 25" AFF L3 GFB OS-11 60" AFF TV N L-43 12" AFF L4 GFB OS-13 N L-43 241 N, Brnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.cor RD Project Number: 218092.00 cO N N c-0 co .-6 '. No. 0033339 r r r ` O CO U O S� � W 0 ^O W C M a� a) O W 4-; -0 � r O C a = � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - LOUNGE & BISTRO - POWER J J U N 00 M N O N N U ¢Sheet Number: U ca E305 Y C '.SUMMIT SMITH DEVELOPMENT 241 N Rrnarlwav COUNTRY KITCHEN 1092 - EQUIPMENT SCHEDULE ITEM. SERVING VOLT PHASE LOAD FEED FROM OCPD BRANCH WIRING DISCONNECT SWITCH MOUNTING HEIGHT OPTIONS SEE NOTE KW AMP HP PANEL CIRCUIT BRANCH SIZE TYPE POLE NO. SIZE COND GRD SIZE FURN BY INST BY WIRED BY LOC. OPTIONS S3 TOASTER, SLOT TYPE 120 1 2.6 15 - NU1-3 71 N 20 CB 1 2 12 3/4 12 - - - - 25" AFF - 1 S4 I INDUCTION RANGE, COUNTERTOP 120 1 1.8 15 - NU1-3 73 N 20 CB 1 2 12 3/4 1 12 - - - - 25" AFF - 1 S5 DISPENSER, SELF -LEVELING PLATE, HEATED 120 1 - 3.8 - NU1-3 75 N 20 CB 1 2 12 3/4 12 - - - - - - 3 S6 DROP -IN SOUP WELL 120 1 6 - NU1-3 77 N 15 CB 1 2 12 3/4 12 - - - - 25" AFF - 1 S7 DROP -IN HOT WELLS 208 3 - 10.1 - NU1-3 79 N 20 CB 3 3 12 3/4 12 EC EC EC NU - 25" AFF 3 S9 WALL OVEN, BUILT IN 208 1 3.2 15 - NU1-3 72 N 20 CB 2 2 12 3/4 12 EC EC EC NU - 25" AFF 3 S11 REFRIGERATOR/FREEZER, DUAL TEMP 120 1 - 6.3 - OS/1-1 1 OS 15 CB 1 2 12 3/4 12 - - - - - 48" AFF - 1 S13 ICE MAKER, UNDERCOUNTER 120 1 - 4.1 - OS/1-1 3 OS 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 S14 TEA BREWER 120 1 - 14.4 - NU1-3 74 N 20 CB 1 2 12 3/4 12 - - - - - 50" AFF - 1,2 S15 COFFEE BREWER 120 1 - 14.4 - NU1-3 76 N 20 CB 1 2 12 3/4 12 - - - - - 50" AFF - 1,2 S18 REFRIGERATOR, REACH -IN 120 1 - 4.2 - OS/1-1 5 OS 15 CB 1 2 12 3/4 12 - - - - - 50" AFF - 1 S21 TOWEL WARMER 120 1 15 - NU1-3 78 N 20 CB 1 1 12 3/4 12 - - - - - 50" AFF - 1,2 ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD LS = LIFE SAFETY BRANCH S = AMPERE RATED SWITCH MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF CR = CRITICAL CARE BRANCH F = AMPERE RATED FUSES CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT EQ = EQUIPMENT SYSTEM OCPD = OVERCURRENT PROTECTIVE DEVICE RVS = REDUCED VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH EM = EMERGENCY SYSTEM EC = ELECTRICAL CONTRACTOR 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS ES = ESSENTIAL SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONE -LINE DIAGRAM OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON -FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNT 3 = DIRECT CONNECTION 6 = WEATHER PROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNT COUNTRY KITCHEN EQUIPMENT SCHEDULE NOTES: 1. E.C. SHALL PROVIDE NEMA 5-15R TYPE RECEPTACLE. 2. EC TO VERIFY ELECTRICAL REQUIREMENTS WITH OWNER/OPERATOR PRIOR TO INSTALLATION. 3. RECEPTACLES ARE PRE -WIRED ON CHEF TABLE. E.C. SHALL PROVIDE WIRING CONNECTION. COUNTRY KITCHEN 2082 - EQUIPMENT SCHEDULE ITEM. SERVING VOLT PHASE LOAD FEED FROM OCPD BRANCH WIRING DISCONNECT SWITCH MOUNTING HEIGHT OPTIONS SEE NOTE KW AMP HP PANEL CIRCUIT BRANCH SIZE TYPE POLE NO. SIZE COND GRD SIZE FURN BY INST BY WIRED BY LOC. OPTIONS S3 TOASTER, SLOT TYPE 120 1 2.6 15 - NU2-3 95 N 20 CB 1 2 12 3/4 12 - - - - 25" AFF - 1 S4 INDUCTION RANGE, COUNTERTOP 120 1 1.8 15 - NU2-3 93 N 20 CB 1 2 12 3/4 12 - - - - - 25" AFF - 1 S5 DISPENSER, SELF -LEVELING PLATE, HEATED 120 1 - 3.8 - NU2-3 97 N 20 CB 1 2 12 3/4 12 - - - - - - 1 on QV mm�m IAI 0^1 Irl 1A/O 1 I [AV -111 QVur WELL ,z IGV 4 1 - G V - All N 9 11L/ V nn Zl.7 AI IN 4' IV flo 110 4 1 O G 4,, IG V/Y 40 IG - - - - - Ocll AMC GV / 11- - 4 1 S7 DROP -IN HOT WELLS 208 3 - 10.1 - NU2-3 101 N 20 CB 3 3 12 3/4 12 EC EC EC NU - 25" AFF 3 S9 WALL OVEN, BUILT IN 208 1 3.2 15 NU2-3 103 N 20 CB 2 2 12 3/4 12 EC EC EC NU - 25" AFF 3 S11 REFRIGERATOR/FREEZER, DUAL TEMP 120 1 - 6.3 OS/2-1 1 OS 15 CB 1 2 12 3/4 12 - - - - - 48" AFF - 1 S13 ICE MAKER, UNDERCOUNTER 120 1 - 4.1 OS/2-1 3 OS 15 CB 1 2 12 3/4 12 - - - - - 25" AFF - 3 S14 TEA BREWER 120 1 - 14.4 - NU2-3 94 N 20 CB 1 2 12 314 12 - - - - - 50" AFF - 1,2 S15 COFFEE BREWER 120 1 - 14.4 - NU2-3 96 N 20 CB 1 2 12 3/4 12 - - - - - 50" AFF - 1,2 S18 REFRIGERATOR, REACH -IN 120 1 - 4.2 - OS/2-1 5 OS 15 CB 1 2 12 3/4 12 - - - - - 50" AFF - 1 S21 TOWEL WARMER 120 1 15 - NU2-3 98 N 20 CB 1 1 12 3/4 12 - - - - 50" AFF - 1,2 ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD LS = LIFE SAFETY BRANCH S = AMPERE RATED SWITCH MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF OS = OPTIONAL STANDBY F = AMPERE RATED FUSES CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT EQ = EQUIPMENT SYSTEM OCPD = OVERCURRENT PROTECTIVE DEVICE RVS = REDUCED VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH EM = EMERGENCY SYSTEM EC = ELECTRICAL CONTRACTOR 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS ES = ESSENTIAL SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONE -LINE DIAGRAM OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON -FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNT 3 = DIRECT CONNECTION 6 = WEATHER PROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNT COUNTRY KITCHEN EQUIPMENT SCHEDULE NOTES: 1. E.C. SHALL PROVIDE NEMA 5-15R TYPE RECEPTACLE. 2. EC TO VERIFY ELECTRICAL REQUIREMENTS WITH OWNER/OPERATOR PRIOR TO INSTALLATION. 3. RECEPTACLES ARE PRE -WIRED ON CHEF TABLE. E.C. SHALL PROVIDE WIRING CONNECTION. IN 25" AFF 25" AFF S7 S3 N L-79 L-71 m C ® j (�N Ire, `C S5 25" AFF 25" AFF NL-75 S6 S4 N L-77 N L-73 GFI N L-81 25" AFF 48" AFF S9 S11 GFB GFB NL-72 OS-1 qPGFI K-�- NL-81 50" AFF 50" AFF 50" AFF S18 S21 S14 Q OS-5 NL-78 NL-74 m 50" AFF 25" AFF S15 S13 NL-76 OS-3 ENLARGED PLAN - FIRST FLOOR COUNTRY KITCHEN - POWER 1 /411=11.01, DETAIL NOTES - A. NORMAL SYSTEMS 208Y/120V "NLII BRANCH POWER SHALL BE FED FROM PANEL NU1-3, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V 110S11 BRANCH POWER SHALL BE FED FROM PANEL OS/1-1, UNLESS OTHERWISE NOTED. KEYED NOTES - 1. KEY OPERATED LOCK OUT SWITCH SHALL SHALL BE PROVIDED TO CONTROL ALL EQUIPMENT EXCEPT THE REFRIGERATOR, ICE AND BEVERAGE MACHINE. KEY TO BE REMOVABLE IN THE OFF POSITION ONLY. 2. VERIFY ELECTRICAL REQUIREMENTS WITH OWNERS APPROVED VENDOR. Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 \ \ , X 1I II I I I / , F coNN, '-C, o Sri ��,. �OPHE1� •0 `. No. 0033339 r 25" AFF 25" AFF d- S7 S3 CU ti NL-101 NL-95 m O S5 25" AFF 25" AFF NL-97 S6 S4 V NL-99 NL-93 (U O L� CIO W 25" AFF 48" AFF >_ S9 NL-103 S11 OS-1 W O C/) O K eg (D C6 C / M 5 C- 50" AFF 50" AFF 50" AFF S18 S21 S14 N OS-5 NL-98 NL-94 L- > ® (Al (* ® ® O w 50" AFF 25" AFF -0 C-0 S15 S13 CU NL-96 OS-3 C a ENLARGED PLAN - SECOND FLOOR COUNTRY KITCHEN - POWER 11411=11.01, DETAIL NOTES - A. NORMAL SYSTEMS 208Y/120V "NL11 BRANCH POWER SHALL BE FED FROM PANEL NU2-3, UNLESS OTHERWISE NOTED. B. NON -ESSENTIAL SYSTEMS 208Y/120V "OSII BRANCH POWER SHALL BE FED FROM PANEL OS/2-1, UNLESS OTHERWISE NOTED. KEYED NOTES - 1. KEY OPERATED LOCK OUT SWITCH SHALL SHALL BE PROVIDED TO CONTROL ALL EQUIPMENT EXCEPT THE REFRIGERATOR, ICE AND BEVERAGE MACHINE. KEY TO BE REMOVABLE IN THE OFF POSITION ONLY. 2. VERIFY ELECTRICAL REQUIREMENTS WITH OWNERS APPROVED VENDOR. Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED PLANS - COUNTRY KITCHENS - POWER J J U N r O M C14 O r- O C14 :a I L U Q Sheet Number: U co CIO E306 .�C C d Q ONE -LINE SYMBOLS MEDIUM VOLTAGE FUSE I MEDIUM VOLTAGE FUSIBLE SWITCH MEDIUM VOLTAGE SWITCH MEDIUM VOLTAGE Q' FUSED CUTOUT MEDIUM VOLTAGE CABLE TER.:"tNATlO.' xX XX --DENOTES THE FOLLOWING: (XX) DEVICE DESIGNATION TYPE - LOW VOLTAGE SEE SPECIFICATION FUSE DENOTES THE FOLLOWING: I (AM) AMMETER (AS) AMMETER SWITCH (DM) DIGITAL METER (M) KWHR METER (VM) VOLTMETER (VS) VOLTMETER SWITCH I LOW VOLTAGE FUSED DISCONNECT SWITCH LOW VOLTAGE DISCONNECT SWITCH LOW VOLTAGE ® CIRCUIT BREAKER LOW VOLTAGE DRAWOUT S/ CIRCUIT BREAKER A LOW VOLTAGE DRAWOUT POWER y CIRCUIT BREAKER I I TRANSFER SWITCH INFORMATION AMPS VOLTAGE CLOSING & WITHSTAND AIC RATING TRANSFER AUTO - AUTOMATIC MAN -MANUAL OPTIONS 1 - LOAD SHED RELAY 2 - BLOCK TRANSFER RELAY 3 - SYNCH CHECK RELAY 4 - PEAK READING AMMETER 5-STANDARD METER 6-VOLTMETER 7 - COMPRESSION LUGS 8- ELEVATOR INTERFACE RELAY 9 - OVERLAPPING NEUTRAL CONTACTS 10 - DIGITAL METERING R W z m O D_ rn I O N WI F-I U W M C_ U 0 2 c� U ATS XXX XXX XXX XXX XXX XXX XXX XXX XXX X /X IX /X IX POTENTIAL TRANSFORMER CURRENT TRANSFORMER SURGE SUPPRESSION xX DENOTES LA = LIGHTNING ARRESTORS SPD = SURGE PROTECTIVE DEVICE 1 CAPACITOR GROUND 1 ®EQUIPMENT CONNECTION - SEE EQUIPMENT SCHEDULE ® JUNCTION BOX G ENGINE GENERATOR TRANSFER SWITCH ID BRANCH N - NORMAL BRANCH LS - LIFE SAFETY BRANCH CR - CRITICAL CARE BRANCH EQ - EQUIPMENT BRANCH EM - EMERGENCY BRANCH ES - ESSENTIAL SYSTEMS NES - NON ESSENTIAL SYSTEMS POLES CYCLE CLOSING & WITHSTAND RATING rvf`I G 30 CYCLE TRANSFER SWITCH TYPE BYPASS NON BYPASS FIRE PUMP TRANSITION OPEN TRANSITION CLOSED TRANSITION DELAYED TRANSITION ® KEY INTERLOCKING - KEY # KEY NORMALLY INSERTED K# -SEE SCHEDULE & DETAILS • KEY INTERLOCKING- KEY # KEY NORMALLY REMOVED K# -SEE SCHEDULE & DETAILS PANELBOARD my TRANSFORMER _ J I I I MANUAL OR AUTOMATIC TRANSFER SWITCH I I I I T NO NO BYPASS ISOLATION TRANSFER SWITCH L NC _ I TRANSFORMER INFORMATION T TRANSFORMERID TYPE DT - DRY TYPE LF - LIQUID FILLED XX XXX kVA kVA DP - DRY TYPE PAD MOUNT LP - LIQUID FILLED PAD MOUNT P: XXX PRIMARY VOLTAGE CR - CAST RESIN EC - ENCAPSULATED CORE S: XXX SECONDARY VOLTAGE RATING XXX XXX TEMPERATURE RISE EE - ENERGY EFFICIENT GP - GENERAL PURPOSE XXX MOUNTING TYPE K-# - K-RATED X / X Ix OPTIONS 1 . KIM] VFAITII AT;=n FPlrl (ICI IPF 2 - INTEGRAL STRIP HEATER 3 - WEATHER SHIELD 4 - NEMA 3R 5 - STAINLESS STEEL I ENCLOSURE XX I DENOTES THE FOLLOWING: (XX) DEVICE DESIGNNATION DENOTES THE FOLLOWING: (ATS) AUTOMATIC TRANSFER SWITCH (BW) BUS WAY (CAP) CAPACITOR (CB) CIRCUIT BREAKER (CON) CONTACTOR (DS) DISCONNECT SWITCH (EDS) ELEVATOR DISCONNECT SWITCH (EDP) ELEVATOR DISTRIBUTION PANEL (F) FUSE (FS) FUSIBLE SWITCH (JB) JUNCTION BOX (,:9TS) MANUAL TRANSFER SWITCH (MVC) MEDIUM VOLTAGE FUSED CUTOUT (MVF) MEDIUM VOLTAGE FUSE (MVFS) MEDIUM VOLTAGE FUSIBLE SWITCH (MVS) MEDIUM VOLTAGE SWITCH (MVT) MEDIUM VOLTAGE CABLE TERMINATION (PLC) POWER LINE CONDITIONER (T) TRANSFORMER (SS) SURGE SUPPRESSION (UPS) UNINTERRUPTIBLE POWER SUPPLY (WW) WIREWAY kX FEEDER CONTINUATION CONNECTION # E)OC FEEDER CONTINUED ON SHEET INDICATED XXXX DEVICE UPSTREAM OR DOWNSTREAM SURGE PROTECTIVE DEVICE SPD TYPE XXX SE -125 kA - SERVICE ENTRANCE BP - 80 kA - BRANCH PANEL XXX OPTIONS X I X I X I X 1 - UNIT STATUS INDICATORS 2 - AUDIBLE ALARM 3 - TRANSIENT COUNTER 4 - REMOTE MONITOR PANEL 5 - SERVICE DISCONNECT SWITCH 6 - SUMMARY ALARM RELAY CONTACTS 7 - HIGH PERFORMANCE INTERCONNECT CABLE 8 - MASTERMIND MONITORING -- SPD ID -- VOLTAGE Z1- OVERLOAD NORMALLY CLOSED CONTACTOR NORMALLY OPEN CONTACTOR j/ FLOAT SWITCH 4e o LIGHT FIXTURE 1 CONTROL SWITCH O� BUS WAY BUS COPPER ALUMINUM CIRCUIT BREAKER INFORMATION I "XXX" - DENOTES AMP RATING i XXXAF -- "AF" - DENOTES AMP FRAME XXXAS — "AS" - DENOTES AMP SENSOR XXXAT -�- "AT" - DENOTES AMP TRIP 3P q xx xXx I 71 xxx CIRCUIT BREAKER ACCESSORIES F�AXX XXX I ALS - ALARM SWITCH AXS AUXILIARY SWITCH EOP - ELECTRIC OPERATOR ST - SHUNT TRIP UVT - UNDER VOLTAGE TRIP CIRCUIT BREAKER OPTIONS AF - ARC FAULT CIRCUIT INTERRUPTER (RESIDENTIAL ONLY) AR - ARC FLASH REDUCTION CL - CURRENT LIMITING FR - FULLY RATED (100%) GE - GROUND FAULT PROTECTION - EQUIPMENT GP - GROUND FAULT PROTECTION - PERSONNEL GS - GROUND FAULT SENSING / ALARM HC - HEATING, COOLING, AIR CONDITIONING, REFRIGERATION - HCAR HM - HIGH MAGNETIC - HID, MOTORS MD - MODIFIED DIFFERENTIAL GROUND FAULT MP - MOTOR CIRCUIT PROTECTOR MS - MOLDED CASE SWITCH L1 - LONG TIME / INSTANTANEOUS - LI L2 - LONG TIME / SHORT TIME / INSTANTANEOUS - LSI L3 - LONG TIME / SHORT TIME / INSTANTANEOUS / GROUND FAULT TRIP - LSIG L4 - LONG TIME / SHORT TIME / INSTANTANEOUS / GROUND FAULT SENSING - LSIA SC - SYSTEM COMMUNICATION SD -SYSTEM DIAGNOSTICS SM - SYSTEM MONITORING ZS - ZONE SELECTIVE INTERLOCKING CIRCUIT BREAKER TYPE MC - MOLDED CASE CIRCUIT BREAKER IC - INSULATED CASE CIRCUIT BREAKER PC - LOW VOLTAGE POWER CIRCUIT BREAKER SS - SOLID STATE MOLDED CASE CIRCUIT BREAKER BW/ XXX AMPS @ XXX VOLTS 3 4W BUS: XXX TYPE: XXX MIN AIC RATING = XXXk AMPS RMS SYM @ XXX VOLTS TYPE INDOOR OUTDOOR LOW VOLTAGE DISCONNECT SWITCH INFORMATION F— "XXX" - DENOTES AMP RATING I XXXAS I XXXAS -- "AS" - DENOTES AMP SWITCH 3P 3P XXXAF XXXAF -� "AF" - DENOTES AMP FUSE D XXX FS XXX (I xxx xxx xxx XXXI xxx DISCONNECT SWITCH ACCESSORIES AXS - AUXILIARY SWITCH DL - DOUBLE LUGS PL - PILOT LIGHT VW - VIEWING WINDOW DISCONNECT SWITCH TYPE DS - UNFUSED DISCONNECT SWITCH EDS - ELEVATOR DISCONNECT SWITCH FS - FUSED DISCONNECT SWITCH GENERAL NOTES - 1. ALL ITEMS INDICATED BY A DARK SOLID LINE AS SHOWN BELOW ARE NEW. 2. ALL ITEMS INDICATED BY A LIGHT DASHED LINE AS SHOWN BELOW ARE EXISTING TO REMAIN. ------------------------------------------ 3. ALL ITEMS INDICATED BY A DARK DASH -DOT -DASH LINE AS SHOWN BELOW ARE EXISTING TO BE REMOVED. 4. ALL ITEMS INDICATED BY A LIGHT DASH -DOT -DASH LINE AS SHOWN BELOW ARE TYPICAL EQUIPMENT DIVISIONS. 5. ALL ITEMS INDICATED BY A LIGHT SOLID LINE AS SHOWN BELOW ARE FUTURE. 6. ALL DOWNTIME SHALL BE SCHEDULED WITH THE OWNER AND SHALL BE KEPT TO AN ABSOLUTE MINIMUM. 7. THE PANELS AND SWITCHBOARDS INDICATED ON THE ONE LINE DIAGRAM SHALL BE PROTECTED FROM AVAILABLE FAULT CURRENT SHOWN BY EITHER OF THE FOLLOWING METHODS: - PROVIDE BREAKERS WITH A MINIMUM AIC RATING GREATER THAN INDICATED - THE SERIES RATING METHOD IS NOT ACCEPTABLE :",SUMMIT SMITH DEVELOPMENT 941 N Rmnrlmyav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D �7u CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com FAA 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.col RD Project Number: 218092.00 `\���IiiilrJrri CONN6 , No. 0033339 ' 141 O. p.�w. v � r � � O O U ^� W L CD O L_ C/) L� > -E-' W O O ^ CW n C)�' U � � � O a � ::D Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ONE LINE DIAGRAM - SYMBOLS Ui U a) C_ U <Sheet Number: C_ U a co E400 Y C IZ ELE, U ELECTRICAL UTILITY SECTION 1 I 3P SS L2 I I F LU z m O ry A In" M V_ O N LUI �I U CD W a) U g UTILITY TRANSFORMER 480Y/277, 3PH, 4W SHORT CIRCUIT CURRENT ESTIMATE A XKVA XFMR @ 4.5%Z) � I I COPPER 8 SETS OF 4 500 kcmil & 1 400 kcmil GRD 4"C. UTILITY TRANSFORMER 208/120, 3PH, 4W SHORT CIRCUIT CURRENT ESTIMATE A (KVA XFMR @ 4.5%Z) I I SPD BP - 80 kA 480Y1277V 1 12 /3 CURRENT TRANSFORMER & METERING CABINET CURRENT TRANSFORMER & METERING CABINET I I I COPPER 8 SETS OF 4 500 kcmil & 1 400 kcmil GRD 4"C. COPPER 6 SETS OF 4 400 kcmil & 1 350 kcmil GRD 4"C. SECTION 1 SECTION 2 PROVIDE MINIMUM SPACES AS FOLLOWS: (4) 250A 3P (4) 600A 3P 2500AF 2500AS 100AF 400AF 800AF 175AF 400AF 2500AT 100AS 250AS 800AS 175AS 400AS I 3P 100AT 150AT 800AT 125AT 400AT L3 L3 I L- - - - MC L3 - - ss L3 - - S M L3 - - MC L3 - - O MC L3 - COPPER ALUMINUM ALUMINUM ALUMINUM ALUMINUM 4 SETS OF 2 SETS OF TO MGB 4 #2 & 4 4 250 kcmil & 4 #210 & 4 250 kcmil & 1 #2 GRD 1 1 #3/0 GRD 1 #4 GRD 1 #1 GRD 1-114"C. 1 1 2-112"C. 1-112"C. 1 2-112"C 100AF 250AF 250AF 250AF 250AF 60AS 200AS 200AS 200AS 200AS 60AT 3P 200AT 3P > 100AT 3P > 200AT 3P 200AT > 3P MC El I MC ✓ MC ri MC MC El COPPER ALUMINUM ALUMINUM ALUMINUM ALUMINUM 4 #6 & 4 250 kcmil & 4 #1 & 4 250 kcmil & 4 250 kcmil & 1 #10 GRD 1 #4 GRD 1 #6 GRD 1 #4 GRD 1 #4 GRD 1 1-1/4"C. 1 21/2"C. 1 1 114"C. 1 2112"C. 1 2 1l2"C. NL NL NL NL sPD 1-2 SPD SE -125 kA 480Y1277V 1 12 13 250AF 250AF 200AS 200AS 200AT 200AT 3P > 3P ALUMINUM ALUMINUM 4 250 kcmil & 4 250 kcmil & 1 #4 GRD 1 #4 GRD 1 2 112"C. 1 2 1l2"C. NL [NL 1-3 1-4 1 250AF 225AS 225AT 3P / MC -77 ALUMINUM 4 300 kcmil & 1 #2 GRD 1 2112"C. NL -5 RTUAA NH 1-1 ` 250AF 800AF 400AF 100AF 100AS 800AS 400AS 90AS 100AT 800AT 400AT 90AT I MC L3 MC L3 MC L3 MnL3 ALUMINUM ALUMINUM ALUMINUM ALUMINUM 4 SETS OF 2 SETS OF 4 #1 & 4 250 kcmil & 4 250 kcmil & 4 #3 & 1 #6 GRD 1 #310 GRD 1 #1 GRD 1 #8 GRD 1 1-1/4"C. 1 2-112"C. 1 2.112"C. 1-112"C. NH 4 NH NH DOAS-1 DO q (ROOF) (R 250AF 400AF 250AF 250AF 200AS 400AS 200AS 200AS 200AT 400AT 200AT 200AT 3P > 3P 3P > 3P MC MC ALUMINUM ALUMINUM ALUMINUM ALUMINUM 4 250 kcmil & 4 250 kcmil & 4 250 kcmil & 4 250 kcmil & 1 #4 GRD 1 #1 GRD 1 #4 GRD 1 #4 GRD 1 2 112"C. 1 2"C. 1 21/2"C. 1 2112"C. NL NL NL NL 1-6 1-K 2-1 2-2 2 100AF 100AF 100AF I 60AT 60AT 90AT 3P 3P 3P I� MC MC MC STR L3 L3 COPPER COPPER ALUMINUM 4 #6 & 4 #6 & 4 #3 & 1 #10 GRD 1 #10 GRD 1 #8 GRD 1 1-1 /4"C. 1 1-114"C. 1.112"C. ® ECS AS-2 DOAS-3 OOF) (ROOF) 2 COPPER 4 #3 & 1 #8 GRD 1-112"C. NL 250AF 250AF 250AF 250AF 100AF 200AS 200AS 250AS 200AS 80AS 200AT 3P > 200AT 3P > 250AT 3P 200AT > 3P 80AT I 3P MC ® MC / MC / MC / MC ALUMINUM ALUMINUM ALUMINUM ALUMINUM COPPER 4 250 kcmil & 4 250 kcmil & 4 350 kcmil & 4 250 kcmil & 4 #4 & 1 #4 GRD 1 #4 GRD 1 #2 GRD 1 #4 GRD 1 #8 GRD 1 21/2"C. 1 21 l2"C. 1 21 /2"C. 1 21 12"C. 1 1-114"C. NL4 Q NL NL ELEV2 40HP 200AF 125AS r 125AT 3P 1.000' IMCI ALUMINUM 4 #210 & 1 #4 GRD 1 2"C. K54.1 K41 -3 2-4 2-5 2-6 BOOSTER CHEFS HEATER TABLE MDP-H 2500 AMPS @ 4801277 VOLTS 3P 4W SWIT(`HBOA RD !`ONSTOII ICTON ♦ .. � VI IuvP\I\v_I I IAUU I WIN MAIN SECTION: INDIVIDUAL FIXED DISTRIBUTION SECTION: GROUP MOUNTED MIN AIC RATING = 65k AMPS RMS SYM @ 480 VOLTS MDP-L 2000 AMPS @ 208/120 VOLTS 3P 4W SWITCHBOARD CONSTRUCTION MAIN SECTION: INDIVIDUAL FIXED DISTRIBUTION SECTION: GROUP MOUNTED MIN AIC RATING = 42k AMPS RMS SYM @ 240 VOLTS r:�: GENERAL NOTES - KEYED NOTES - Q 1. ALL ITEMS INDICATED BY A DARK SOLID LINE AS SHOWN BELOW 1. SERVICE INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS ARE NEW. INCLUDED WITHIN CONNETICUT LIGHT & POWER UTILITY "INFORMATION AND REQUIREMENTS FOR ELECTRICAL SERVICE" MANUAL, LATEST EDITION. 2. ALL ITEMS INDICATED BY A LIGHT DASHED LINE AS SHOWN BELOW 2. COORDINATE THE PROVISIONS OF CONDUIT, CONDUCTORS AND ARE EXISTING TO REMAIN. INFRASTRUCTURE TO THE CURB FOR THE INSTALLATION OF ------------------------------------------ INCOMING SERVICES TO THE FACILITY WITH CONNETICUT LIGHT & POWER. 3. ALL ITEMS INDICATED BY A DARK DASH -DOT -DASH LINE AS SHOWN 3. E.C. SHALL PROVIDE (2) 41NCH PVC SCHEDULE 40 CONDUITS FROM BELOW ARE EXISTING TO BE REMOVED. CURB LINE TO UTILITY TRANSFORMER PAD LOCATION. CONDUITS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - NOT INTENDED TO BE INSTALLED WITHIN CONCRETE ENCASED DUCT BANK, EXCEPT WHERE EXTENDS BENEATH ROADWAY. COORDINATE CONDUIT SIZE WITH CONNETICUT LIGHT & POWER. 4. ALL ITEMS INDICATED BY A LIGHT DASH -DOT -DASH LINE AS SHOWN PROVIDE TRENCHING, GRAVEL, SUPPORTS, WARNING TAPE, ETC, AS BELOW ARE TYPICAL EQUIPMENT DIVISIONS. REQUIRED WITHIN LOCAL UTILITY INSTALLATION MANUAL. - - - - - - PRIMARY CONDUCTORS SHALL BE PROVIDED AND INSTALLED BY LOCAL UTILITY. 5. ALL ITEMS INDICATED BY A LIGHT SOLID LINE AS SHOWN BELOW 4. E.C. SHALL PROVIDE A PRECAST CONCRETE PAD, COORDINATE ARE FUTURE. INSTALLATION REQUIREMENTS WITH CONNETICUT LIGHT & POWER PRIOR TO CONSTRUCTION. 6. ALL DOWNTIME SHALL BE SCHEDULED WITH THE OWNER AND 5. UTILITY TRANSFORMER PROVIDED BY CONNETICUT LIGHT & POWER. SHALL BE KEPT TO AN ABSOLUTE MINIMUM. 6. E.C. SHALL PROVIDE GROUNDING CONNECTIONS AT THE UTILITY 7. THE PANELS AND SWITCHBOARDS INDICATED ON THE ONE LINE TRANSFORMER PER LOCAL UTILITY REQUIREMENTS. DIAGRAM SHALL BE PROTECTED FROM AVAILABLE FAULT CURRENT SHOWN BY EITHER OF THE FOLLOWING 7. E.C. SHALL PROVIDE AND INSTALL CURRENT TRANSFORMER AND METHODS: METERING CABINET. CONNECTION BETWEEN THE METERING AND - PROVIDE BREAKERS WITH A MINIMUM AIC RATING GREATER CURRENT TRANSFORMER CABINET SHALL BE RIGID STEEL THAN INDICATED CONDUIT. COORDINATE APPROVED LOCATION AND EQUIPMENT - THE SERIES RATING METHOD IS NOT ACCEPTABLE REQUIREMENTS WITH CONNETICUT LIGHT & POWER PRIOR TO INSTALLATION. r 9UMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CM 13 M [Oil � 7 ILLF_� CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.17001 Fax: 414.778.2360 / r-d@ringdu.col RD Project Number: 218092.00 \\\\��IIItllrrri�i c0NNF � co i •� `� No 0033339 O CD O U ^� W s.= O U) CD / =� W O 4- 0 'W v I Co m o UJ � U C1 � O -17 Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ONE LINE DIAGRAM i N O ti M N O N N U Q Sheet Number: U a ICUE401 .Y C d 6G n GEN1 G1111 C� 350 kW / 437.5 kVA, DIESEL GENERATOR CKI GEN 480Y/277V, 3-PHASE, 4-WIRE WEATHER TIGHT ENCLOSURE 1 NON-SEPERATELY DERIVED SOURCE 400AF 800AF 250AS 800AS 150AT 800AT 3P / 3P SS J SS L4 L4 _ ALUMINUM ALUMINUM 4 SETS OF 4 #310 & 4 250 kcmil & I `� 1 #4 GRD 1 #3/0 GRD 1 1.1/2"C. 1 2-1/2"C. 120/208V SERVICES: - BATTERY CHARGER - STRIP HEATER - BLANKET WARMER (BATTERY) - ENGINE JACKET HEATER DS DS EM OS I 1-1/4" C TO GENERATOR WITH WIRING FOR REMOTE i MONITORING 200AS I 800AS L J 3P I I I DS I I I ALUMINUM 3 #3/0 & 1 #4 GRD 1 1-1 /2"C. ATS-EM 150 AMPS ES 480Y/277V 4 POLE 3 l^iYVLG AUTO I NON BYPASS OPEN TRANSITION 10 T- DT 75 kVA P: 480V DELTA S: 208Y/120V EE I 150°C FLCOR 400AF PROVIDE SPACES AS FOLLOWS: 400AS (4) 100A 3P 300AT I 3P / J SS L2 400AF 400AF 400AF 400AF 100AF 250AS 250AS 250AS 250AS 60AS 100AT 3P 100AT 3P 100AT 3P 100AT 3P 100AT 3P ss L2 I — — — ss L2 — — — ss L2 — — ss L2 — — ss L2 — — — — — — — — — ALUMINUM ALUMINUM ALUMINUM ALUMINUM — — ALUMINUM 4 #1 & 4 #1 & 4 #1 & 4 #1 & 4 #6 & 1 #6 GRD 1 #6 GRD 1 #6 GRD 1 #6 GRD 1 #10 GRD 1-1 /4"C. 1-1 /4"C. 1-1 /4"C. 1-1 /4"C. 1-1 /4"C. EM EM EM1-1 F2�-m 1-2 1 2-2 EMLD 175 AMPS @ 2081120 VOLTS 3P 4W MAIN SECTION: GROUP MOUNTED DISTRIBUTION SECTION: GROUP MOUNTED MIN AIC RATING = 10k AMPS RMS SYM @ 240 VOLTS OSHD 800 .AMPS @ 480/277 VOLTS 3P 4W POWER PANEL CONSTRUCTION MAIN SECTION: GROUP MOUNTED DISTRIBUTION SFCTION- GROIIP MOUNTED r6RM AIC RATING = k AMPS ;; SYM @ 480 VOLTS l-- - L21 - - - - ALUMINUM - COPPER - - COPPER 3 #3/0 & 4 #3 & 4 #3 & 1 #4 GRD 1 #8 GRD 1 #8 GRD 1 1-1/2"C. 1 1-112"C. 1-1/2"C. ECS ECS -r� ' 1 3 DT 1 75 kVA ALUMINUM P: 480V DELTA _ _ COPPER COPPER S: 208Y/120V 4 500 kcmil & 1 #2 GRD 4 #3 & 4 #3 & EE 150°C 1 3"C. 1 #8 GRD 1 #8 GRD FLOOR 1-1/2"C. 1-1/2"C. ELEV1 40HP ELEV3 40HP W I� COPPER COPPER 4 250 kcmil & 4 #6 & 1 #4 GRD 1 #6 GRD 1 3"C. 111C. ®SH SPD 1-1 BP - 80 kA SPD i 480YI277V J- 1 I2 13 400AF PROVIDE SPACES AS FOLLOWS: 300AS (2) 100A 3P 300AT 3P fT-1 - � ss - � s�L2 - � ss - � ss L2 L2 L2 I l— — — — — — — — — — — — — — — — — — — — — ALUMINUM ALUMINUM ALUMINUM ALUMINUM 4 #1 & 4 #3 & 4 #1 & 4 #1 & 1 #6 GRD 1 #4 GRD 1 #6 GRD 1 #6 GRD 1-1/4"C. 1-1/2"C. 1-1/4"C. 1-1/4"C. KEYED NOTES - C'1 1. PROVIDE 120Y/208V POWER FROM PANEL EMLD FOR GENERATOR ACCESSORIES. 2. GENERATOR ENCLOSURE SHALL INCLUDE LOAD CENTER FOR CONNECTION TO ACCESSORIES. 3. GENERATOR SHALL PROVIDE DIESEL FUEL FOR 48 HOURS OF RUN TIME. REFERENCE SPECIFICATIONS SECTION 26 32 05 FOR ADDITIONAL INFORMATION. 241 N. BrOadwav Suite 400 - Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 0 ICD 03RqU7y'd UUIVj I KUU 1 IVIV or-MVIur-0 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414,778,2360 / r-d@ringdu.col RD Project Number: 218092,00 .��10 O . NE• T � co cr` No. 0033339 QJ ` I 1 O CD O U ^� W L O i W O % — U) 0 ^ rW v , M (3) C- (3) U 0^ U U C r O --r a � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ONE LINE DIAGRAM n CV O ti M CV O O CV L U Q Sheet Number: U C6 E402 elf S= '.SUMMIT SMITH DEVELOPMENT R w z m O ry 0 rn I O N w I �I U W 0 CU 0 L Cz Z NI O O 00 a� E U 0 0 W 0 L L Qi en ZD W KEYED NOTES -a 1. FIXTURE 2. COVE BY GC 3. WOOD BLOCKING BY GC 4. CEILING 3 COVE LIGHTING DETAIL -A NOT TO SCALE NORMAL POWER —v NORMAL POWER / —O 0 GENERAL NOTES 1. DETAIL INDICATES A TYPICAL NETWORKED LIGHTING CONTROL SYSTEM ONE LINE. SEE FLOOR PLANS FOR QUANTITY AND LOCATION OF PANEL(S). PROVIDE THE NECESSARY CONTROL COMPONENTS AND WIRING FOR A COMPLETE SYSTEM. ONE LINE IS DIAGRAMMATIC TO SHOW INTENT OF CONNECTIONS BUT DOES NOT SHOW EACH INSTANCE OF CONNECTION ON SYSTEM. 2. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR MORE INFORMATION. 3. SEE FLOOR PLANS FOR QUANTITIES, TYPES AND LOCATIONS OF ALL ASSOCIATED DEVICES. 4. DIAGRAM DOES NOT INCLUDE ANY LOCAL LINE VOLTAGE CONTROL DEVICES. REFER TO FLOOR PLANS FOR TYPES AND /li IAAITITI17Q wumily I I I ICJ. 5. LIGHTING CONTROL PANEL AND LOW VOLTAGE SWITCH(ES) SHALL CONTROL THE LIGHTS ON/OFF VIA RELAYS. ONCE LIGHTS ARE ENERGIZED, LOCAL DIMMING DAYLIGHT SENSOR SHALL DIM LIGHTS IN DAYLIGHT ZONE ACCORDING TO NATURAL LIGHT CONTRIBUTION. KEYED NOTES - Q 1. LOW VOLTAGE SWITCH STATION CONNECTION. USE MANUFACTURER RECOMMENDED WIRE, 2. LOW VOLTAGE CONNECTION FROM LOCAL LOW VOLTAGE DEVICES. USE MANUFACTURER RECOMMENDED WIRE FOR EACH DEVICE TYPE. 3. TCP/IP CONNECTION TO BUILDING LAN TO ALLOW PROGRAMMING AND OVERRIDE ACCESS TO LIGHTING CONTROL SYSTEM. 4. POWER CONNECTION FOR LIGHTING CONTROL PANEL. 5. NOTE NOT USED. 6. LIGHTING CONTROL SYSTEM NETWORK BUS. USE MANUFACTURER RECOMMENDED WIRE. PROVIDE SYSTEM BOOSTERS OR REPEATERS AS NECESSARY TO ACCOMODATE QUANTITY OF LIGHTING CONTROL PANELS, DISTANCE RUN AND ALL ASSOCIATED DEVICES. LIGHTING CONTROL PANEL DETAIL - NETWORK SYSTEM NOT TO SCALE NTROLPANEL FIXTURES NORMAL OR CRITICAL POWER DETAIL NOTES - 1 . DETAIL INDICATES A TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM. SEE FLOOR PLANS IFOR THE REQUIRED LIGHTING CONTROL CONFIGURATION. PROVIDE THE NECESSARY CONTROL COMPONENTS AND WIRING FOR A COMPLETE SYSTEM. 2. SEE FLOOR PLANS FOR QUANTITIES, TYPES AND LOCATIONS OF OCCUPANCY SENSORS. 3. ALL FIXTURES LOCATED IN THE ROOM MONITORED BY OCCUPANCY SENSORS SHALL BE CONTROLLED BY THESE SENSORS. KEYED NOTES -a 1. MOUNT INJUNCTION BOX ABOVE ACCESSIBLE CEILING. TYPICAL CEILING MOUNTED, SINGLE CIRCUIT OCCUPANCY SENSOR DETAIL NOT TO SCALE 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 an Me60 DUCHATEAU 17400 West Capitol Drive - Brookfield. WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cot RD Project Number: 218092.00 �•� aF G O N NF�T HER •%'G z I - d . No. 00333 , O O � U O W U) 0 cn (5 C)CD 0 W U � � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LIGHTING DETAIL 0— J J Ui U N No "I U Q Sheet Number: C_ U Cn a c6 E500 c '.SUMMIT SMITH DEVELOPMEIVVT LY LY LY i LX LY LY LY KEYED NOTES, - <7 H2-11 _I-1„L s.1'LL a� .,at,p I�t iI1:HLt„I IHk I°Ue1 ;fF 14i. T' hIL!!l. 1 &1i.11* - 1 11lki.@ I IV'P_1 #%" 2 "NIUNt %J4ALL KL VM.W1kLI A- Imt Ufd JK LF 11-t C&%5rk1 F!_LU +r w I I.1L 311Fp-q - L+1 I a I I7fIIarL K-uLL KL AQ-L "..IF. IL.0 lidI-IIF40 I'-r 1v IH Fi x I I_Li'L K-u.L L Kt "U FJ I t U NU 11-t LI-Ti r C_. U w_L:1 t o e_vj1 1 i 1 15"r1 al.i y i o,ae_!t Il ojrj1imL 1 I-i-v:m-p111-t LY LY LY XrYED 40TE:� - . fl:.:tii'JI W I V t;�+1-arum..ft 17J- 11-t F-TJNI 1.1Sl .J. 1W 1- c S-ir �'. L%. 1F.I7NJ 1'!_-&.8.. M WN W.I-'1 1!al&.111 11 a.'Au :IF F"I IM'ft Fki IVNt tt luW111 LL AJ 11441 LIN*4I ej 4fI t,:I tiU° 1'.-; Lvj-1r I1-t KLX M4yAL- 1Y° I!t 1.ftLa %"_H*,V LSASV.r LUCA-KYJ`!11IIIH LLHk:H11t:U-ICTAILiltH AW011P FIKKkE MKOR 01M11) UORMIC 0MUL KEYEE NOTE ._` r. a �-b -,L LJL tL ' - -W J I f 4 I .1 t N-' K!�ktt I_IF 11- t. �_ 1 i. 11111. 1'44 • ' °. ✓VI1. r .-. • '. t l 91 MM.1 N M1.1 Ls.0 - 17.✓$.1 t °.M. aw f 41. L if 'L iw Y• ;ti..._ . F xI FI 1I114:..:1'i5�1. ift 1W1;"11NI LLi ".I Hr.I LN.OHI E1, U -ft C i t `I I IJi _ " I r 11t 5d .x '.y NA Li & Ij,,t 1` q: _U '•'LM'- Y L&,LC I _ Zk: L I I U H W4 - H sl 1�i." r LIB. r.1 ! 1+: V17 ')Al KI RrngrAA1n%1 L—r 1 IY. {JIVGNVVGy Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Websitewww.summitsmith.cc CD 93M�Tm CONSTRUCTION SERVICE 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Websitewww.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 -RING & L, � UUUNA I CAU 17400 West Capitol Drive - Brookfield, WI 5304 Phone: 414.778.28092 414.778.2360 / r-dl RD Project Numt 100 C13 CO 5 U W 0 O W -I--� W O O Cn CU O C O W Issuance / Revisions Date & Issued For: CONSTRUCTION Sheet Name: LIGHTING DETAILS J J a t U "Sheet Number: CU ry U S=E501 TYPICAL BRANCH CKT TYPICAL BRANCH CKT TYPICAL TYPICAL TYPICAL PANELBOARD OR PANELBOARD OR PANELBOARD OR SWITCHBOARD SWITCHBOARD SWITCHBOARD NEUTRALBUS NEUTRAL BUS NEUTRALBUS GROUND BUS GROUND BUS GROUNDBUS TYPICAL FEEDER TYPICAL BRANCH CKT TYPICAL TYPICAL I I TRANSFER SWITCH FTY—PICAL 14-7 F T NSFORMER � SERVICE ENTRA:NC � I I RANSFORMER EQUIPMENT I • ad °dam ° S d°e .°d' I I Q, ° NEUTRALBUS NEUTRALBUS NEUTRALBUS NEUTRAL BUS .a^ a8 a 3 I !a (,Rnl Mir) RI IC r-pnI Mir) RI IC I <= (I-DnI Min RI IC <= (,Rnl IKIn RI IC 'I' -'I �.V VII✓ UIJV i �VVIVV LIVIJ �.V V1=✓ LJVV �.VVIIv vVv DETAIL NOTES - 1. THIS DETAIL APPLIES TO CONDUIT PENETRATIONS THROUGH FLOORS. 2. E.C. SHALL BE RESPONSIBLE FOR MAINTAINING INTEGRITY OF THE MATERIAL AND CONSTRUCTION TYPE AT EACH FIRE RATED ASSEMBLY WHERE PENTRATION OF CONDUIT OR RACEWAY OCCURS. KEYED NOTES -e--i 1. FLOOR SLAB 2. METALLIC SLEEVE 3. METALLIC CONDUIT 4. FiRE 1. I — 11�1TE;Iv"ESCE"11T 1v"ATERiAL 2 ) CONDUIT PENETRATION THRU FLOORS NOT TO SCALE r 00 O t` N rn 0 N GENERATOR G NEUTRALBUS GROUNDBUS I — — — Ll SERVICE ENTRANCE ROOM GROUNDBUS GRD B TYPICAL TELECOMMUNICATIONS ROOM GROUNDBUS GRD A u V� INCOMMING BUILDING BUILDING EXTERIOR INCOMMING WATER STEEL REBAR GROUND SERVICE SERVICE (UFER) RODS CONDUITS � SYSTEM GROUNDING RISER ��NOT TO SCALE 3'-0" BFG MIN. T-6" 7 1 /2" 2'-9" KEYED NOTES -n 1. GRADE BENEATH ROADWAY - LOAD BEARING SURFACE 2. YELLOW PLASTIC WARNING TAPE 3. PVC DUCTBANK SPACER 6'-0" OC MAXIMUM. STAKE INTO EARTH 4. 4" SCHEDULE 40 PVC (TYPICAL) 5. #5 REBARS CONTINUOUS 6. CONCRETE ENVELOPE 4 TYPICAL DUCTBANK SECTION 4x2 NOT TO SCALE SWITCH FIRE PIT EMERGENCY ON -OFF SHUT OFF 120VAC TRANSFORMER 24VAC —gh w 24VAC ELECTRONIC SOLENOIDS IGNITION Ld BURNER DEDICATED BREAKER 120VAC EMERGENCY POWER ROOM GROUNDBUS GRD B KEYED NOTES -a 1. NEUTRAL CONDUCTOR SHALL BE SIZED AS INDICATED ON THE ONELINE DIAGRAMS OR AS SHOWN WITHIN THE EQU1PIVIEN T C 0 N N E C T IV IV SCHEDULED. 2. GROUNDING CONDUCTOR SHALL BE SIZED AS INDICATED ON THE ONELINE DIAGRAMS OR AS SHOWN WITHIN THE EQUIPMENT CONNECTION SCHEDULED. 3. 3/0 COPPER GROUNDING ELECTRODE CONDUCTOR. 4. 3/0 COPPER GROUNDING CONDUCTOR. 5. GROUND ALL TELECOMMUNICATIONS ROOM EQUIPMENT AS DESIGNED WITHIN THE DIRECT SUPPLY TELECOMMUNICATIONS SYSTEMS DRAWINGS. GROUND BUS SHALL BE INSTALLED IN THE FOLLOWING ROOMS: (0023 DEMARK, 1014 IT ROOM, 1042A IT ROOM, 1094 IT ROOM, 2015 IT ROOM, 2045 IT ROOM) 6. PROVIDE GROUNDING ELECTRODE CONDUCTOR FOR EACH DRY TYPE TRANSFORMER LOCATED IN THE AREA OF THE GROUND BUS. CONDUCTOR SIZE DETERMINED PER NEC ARTICLE 250. 7. NEUTRAL TO GROUND BOND ONLY INSTALLED AT SEPARATELY DERIVED SOURCES. THE SEPARATELY DERIVED SOURCES INCLUDED IN THIS PROJECT CONSIST OF THE SERVICE ENTRANCE EQUIPMENT (MDP-H) AND EACH TRANSFORMER. 13" I—I-1 -I — — I- — —I -� — — 4 1-1-1 16" 58" 16" 811 TYP DETAIL NOTES - 1. CONCRETE SHALL HAVE A MINIMUM STRENGTH OF 3000 POUNDS PER SQUARE INCH AND CONTAIN NOT LESS THAN 6 BAGS OF CEMENT PER CUBIC YARD. APPROX. ONE BAG OF FLY ASH MAY BE SUBSTITUTED FOR ONE BAG OF CEMENT PER CUBIC YARD OF CONCRETE. CONCRETE TO BE AIR ENTRAINED. 2. COORDINATE EXACT SIZE AND REQUIREMENTS WITH PSE&G PRIOR TO INSTALLATION. KEYED NOTES 1' PROVIDE ADDITIONAL #3 BARS TO HAVE MINIMUM OF (30 IN 16" WIDITH (TYPICAL OF 20) 2• #3 REBAR 12" OC EACH WAY WITH 3" CLEAR COVER TO EDGE OF PAD 3' #3 X 2'-0" DIAGONAL AT EACH CORNER OF OPENING 4• PROVIDE (2) #3 IN 13" WIDTH 5' ABOVE GROUND SECONDARY CONDUITS TO BUILDING 6' PROTECTIVE BUSHING 7• (2) 4" PRIMARY CONDUITS 8' FOOTINGS 9. (2) 4" PVC CONDUITS STUB PRIMARY CONDUITS OUTSIDE OF PAD 36" MIN R r 1 /2" 3H VE (9)'2JW111 IV ITT, 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com coi n F1 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 Q I I^ 11 k_1 LX DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778,1700 I Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 0 CD U L O 70 2).- �44. -�--' W 0 U) v a c N U O^ W i � U r Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: POWER DETAILS Sheet Number: U N a cB aE51 0 o.. Aa FIREPIT WIRING DIAGRAM 5OT TO SCALE N TRANSFORMER PAD 3 NOT TO SCALE [; SUMMIT SMITH DIE VELOPMENT VON HIGHEST FLOOR INTERMEDIATE FLOORS (TYPICAL) LOWEST FLOOR P. U SP SP SP 11 O OF 10 SP HC ELEVATOR CAB ELEVATOR PIT LOBBY/HOISTWAY ELEVATOR MACHINE ROOM TO OVERCURRENT PROTECTIVE DEVICE POWER MODULE SWITCH nI II IA--IY I ELEVATOR MOTOR I AUX = ELEVATOR CONTROLER THE BATTERY LOWERING SYSTEM (BLS) INTERFACE MAY NOT BE REQUIRED. THE BLS IS ONLY USED FOR HYDRAULIC ELEVATORS. TYPICAL FIRE ALARM AND ELEVATOR CONTROL DETAIL NOT TO SCALE DETAIL NOTES - 1 . THE PRIMARY AND SECONDARY ELEVATOR RECALL FLOORS WILL BE DEFINED BY THE ARCHITECT. THE EC SHALL COORDINATE THE PROGRAMMING OF THESE RECALL FLOORS WITHIN THE FIRE ALARM SYSTEM WITH THE ARCHITECT AND THE FIRE ALARM SYSTEM INSTALLER. 2. EC SHALL PROVIDE ALL DEVICES AND INTERFACES NECESSARY FOR A COMPLETE AND OPERATIONAL ELEVATOR RECALL SYSTEM. 3. ALL ITEMS INDICATED BY A DARK SOLID LINE AS SHOWN ABOVE ARE BY EC. 4. -- ALL ITEMS INDICATED BY A DASH -DOT -DASH LINE AS SHOWN ABOVE IS TYPICAL EQUIPMENT DIVISIONS. 5. ALL ITEMS INDICATED BY LIGHT SOLID LINE AS SHOWN ABOVE ARE BY POWER MODULE MANUFACTURER. KEYED NOTES -a 1. CONTROL. MODULE "FA3" LOCATED AT POWER MODULE SWITCH. CONTROL MODULE "FA3" SHALL ENERGIZE THE NORMALLY OPEN RELAY "C2", WHICH ACTIVATES THE SHUNT TRIP ON CIRCUIT BREAKER(S) SERVING ELEVATOR MOTOR. SEE ONE LINE DIAGRAM FOR MORE DETAILS. 2. PROVIDE A MONITOR MODULE "FA1" FOR MONITORING SHUNT TRIP CONTROL POWER INTEGRITY. MONITOR MODULE SHALL MONITOR THE STATE OF SUPERVISORY R E LAY "C'I ". 3. NOT USED 4. SMOKE DETECTOR(S) LOCATED IN ELEVATOR LOBBY(S). UPON ALARM, SMOKE DETECTOR(S) SHALL INITIATE THE ELEVATOR RECALL PROCEDURE TO DESIGNATED EXIT LEVEL. CIRCUIT BREAKER SERVING ELEVATOR MOTOR AND ELEVATOR CAB DEVICES SHALL REMAIN ENERGIZED UPON ALARM. SEE FLOOR PLANS FOR EXACT LOCATION AND NUMBER OF SMOKE DETECTOR(S). 5. HEAT DETECTOR(S) LOCATED IN ELEVATOR MACHINE ROOM. HEAT DETECTOR(S) SHALL HAVE A LOWER RESPONSE TIME INDEX (RTI) AND LOWER TEMPERATURE SETTING THAN THE SPRINKLERS PROTECTING THE ELEVATOR MACHINE ROOM, UPON ALARM, HEAT DETECTOR(S) SHALL INITIATE DE -ENERGIZING THE CIRCUIT BREAKER SERVING ELEVATOR MOTOR. PROVIDE (1) DETECTOR WITHIN 2' OF EACH SPRINKLER HEAD SERVING THE MACHINE ROOM. COORDINATE EXACT QUANTITY AND LOCATION WITH FIRE PROTECTION CONTRACTOR. 6. SMOKE DETECTOR(S) LOCATED IN ELEVATOR MACHINE ROOM. UPON ALARM, SMOKE DETECTOR(S) SHALL INITIATE THE ELEVATOR RECALL PROCEDURE. SEE FLOOR PLAN FOR EXACT NUMBER AND LOCATION OF SMOKE DETECTOR(S). 7. CONTROL. MODULE "FAT" LOCATED AT ELEVATOR CONTROL PANEL. CONTROL MODULE TO NOTIFY THE ELEVATOR CONTROL. PANEL THAT THE SMOKE DETECTOR IN THE ELEVATOR LOBBY ON THE PRIMARY ELEVATOR RECALL FLOOR IS IN ALARM. SEE NOTE 1. 8. CONTROL. MODULE "FA2" LOCATED AT ELEVATOR CONTROL PANEL. CONTROL MODULE TO NOTIFY THE ELEVATOR CONTROL, PANEL THAT THE SMOKE DETECTOR IN THE ELEVATOR LOBBY ON THE SECONDARY ELEVATOR RECALL FLOOR IS IN ALARM. SEE NOTE 1. 9. CONTROL. MODULE "FA4" SHALL PROVIDE A SIGNAL TO THE ELEVATOR CONTROL PANEL IF THE SMOKE DETECTORS IN THE ELEVATOR MACHINE ROOM OR THE ELEVATOR HOISTWAY (IF SHOWN AS INSTALLED PER THIS DETAIL) ENTER ALARM. THIS SIGNAL SHALL CAUSE THE FIREMAN'S INDICATOR LIGHT IN THE ELEVATOR CAB TO FLASH. 10. HEAT DETECTOR(S) LOCATED AT TOP OF ELEVATOR HOISTWAY. HEAT DETECTOR(S) SHALL HAVE A LOWER RESPONSE TIME INDEX (RTI) AND LOWER TEMPERATURE SETTING THAN THE SPRINKLER HEAD(S) PROTECTING THE ELEVATOR HOISTWAY. UPON ALARM, HEAT DETECTOR SHALL INITIATE DE -ENERGIZING THE CIRCUIT BREAKER SERVING ELEVATOR MOTOR AND ELEVATOR CAB DEVICES. PROVIDE (1) DETECTOR WITHIN 2' OF EACH SPRINKLER HEAD SERVING THE TOP OF THE HOISTWAY. COORDINATE EXACT QUANTITY AND LOCATION WITH FIRE PROTECTION CONTRACTOR. 11. SMOKE DETECTOR(S) LOCATED IN ELEVATOR HOISTWAY. UPON ALARM, SMOKE DETECTOR(S) SHALL INITIATE THE ELEVATOR RECALL PROCEDURE. SEE FLOOR PLAN FOR EXACT NUMBER AND LOCATION OF SMOKE DETECTOR(S). 12. CONNECT THE BATTERY LOWERING SYSTEM FOR HYDRAULIC ELEVATOR. 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm 13 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & u E DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.coi RD Project Number: 218092.00 C0 N ^!FC, No. 0033339 4o r ` r i Z _ f' O co C— U L o W �1— O C N L- U 0 w � U � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TECHNOLOGY DETAIL i n co O r` CM N_ O N U <Sheet Number: co E520 �N c Y C d W Z m O I rn 0 N U 75 r M 0 r` CM CV rn 0 N LIGHT FIXTURE SCHEDULE CONTINUES ON E601 LIGHT FIXTURE SCHEDULE FIXTURE LIGHT SOURCE BALLASTS/DRIVERS INPUT WATTS VOLT MOUNT SURFACE TYPE FIXTURE DEPTH FIXTURE SPECIFICATION AND ACCEPTABLE MANUFACTURERS OPTIONS SEE NOTE ID DESCRIPTION TYPE NO. DESCRIPTION WATTS K CRI MIN.) TYPE CONTROL NO. MANUFACTURER CATALOG SERIES 2X4 TROFFER 4000 COLUMBIA LLT24-30_ LW_G_FS_-A19F_ED_U AA FROSTED PRISMATIC LENS #A19 PATTERN LED - DELIVERED 31 3000 80 DR DM10 1 31 MVOLT R LG <5" 1,2 1C LUMENS------------------------------------------------------------------------- 2X4 LENSED TROFFER 4900 COLUMBIA LLT24-30-ML-G-FS-Ai-ED-U-G1 AE SEALED AND GASKETED; LED - DELIVERED 38 3000 80 DR DM10 1 38 MVOLT R LG <5" ----------------------------------------------------------------------------------------- 1,2,19 1C FROSTED PRISMATIC LENS #A19 PATTERN LUMENS ----------------------------------------------------------------------------------------- 2X4 VOLUMETRIC TROFFER 3800 COLUMBIA LCAT24-30-MWHIE-G-ED-U AN CURVED CENTER LENS LED - DELIVERED 31 3000 80 DR DM10 1 31 MVOLT R LG <5" ----------------------------------------------------------------------------------------- 1 1C LUMENS ---------------------- ----------------------------------------------------------------- 2X4 VOLUMETRIC TROFFER 5400 COLUMBIA LCAT24-30-HL-G-ED-U AP CURVED CENTER LENS LED - DELIVERED 44 3000 80 DR DM10 1 36 MVOLT R LG <5" ------------------------- - ---- -------------------------------------------- 1 1C LUMENS ----------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------- 1X4 TROFFER - GASKETED 3800 COLUMBIA LLT14-30-VL-G-FS-A19F-ED-U-G1 BE SEALED AND GASKETED; LED - DELIVERED 45 3000 80 DR DM10 1 45 MVOLT R LG <4" ------------------------------------------------ 1,2,19 1C FROSTED PRISMATIC LENS #A19 PATTERN LUMENS ----------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------- ----------------------------------------------------------------------------------------- 2X2 TROFFER 3300 COLUMBIA LJT22-30-ML-G-FS-A19F-ED-U CA FROSTED PRISMATIC LENS #A19 PATTERN LED - DELIVERED 31 3000 80 DR SW 1 31 MVOLT R LG <5" ------------------ ---------------------------------------------------------------- 1,2 1C LUMENS ----------------------------------------------------------------------------------------- 2X2 VOLUMETRIC TROFFER 2000 COLUMBIA LCAT22-30-MW-G-ED-U CN CURVED CENTER LENS LED - DELIVERED 18 3000 80 DR DM10 1 18 MVOLT R LG <5" ----------------------------------------------------------------------------------------- 1 1C LUMENS ----------------------------------------------------------------------------------------- 2X2 VOLUMETRIC TROFFER 3300 COLUMBIA LCAT22-30-ML-G-ED-U CP CURVED CENTER LENS LED - DELIVERED 29 3000 80 DR DM10 1 29 MVOLT R LG <5" ----------------------------------------------------------------------------------------- 1 1C LUMENS----------------------------------------------------- ----------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- 4" APERTURE DOWNLIGHT 1600 SPECTRUM LIGHTING SP4ES-20L-30K-DX / AR4ES-SG-MF DA WIDE DISTRIBUTION LED - DELIVERED 20 3000 80 DR DIM10 1 20 MVOLT R V <6" ---------- ------------------------------------------------------------------------ 30,41 1F LUMENS ----------------------------------------------------------------------------------------- 5" APERATURE DOWNLIGHT 3600 SPECTRUM LIGHTING SGE5LEDOS-45L-30K-DS10-SCA DB WIDE DISTRIBUTION LED - DELIVERED 42 3000 80 DR DIM10 1 42 MVOLT R DW <5" ----------------------------------------------------------------------------------------- 30,39,41 1F SLOPED CEILING ADAPTER LUMENS 4" APERTURE DOWNLIGHT 2800 SPECTRUM LIGHTING SGEF4LEDOS-45L•-30K-DS10/ DC WIDE DISTRIBUTION LED - DELIVERED 42 3000 80 DR DM10 1 42 MVOLT R V <6" FC42230S-SG 30,41 1F LUMENS ----------------------------------------------------------------------------------------- 4" APERATURE WALL WASHER 1600 SPECTRUM LIGHTING SP4ES-20L-30K-DX / AIR4WES-SG-MF DD WIDE DISTRIBUTION LED - DELIVERED 20 3000 80 DR DIM10 1 20 MVOLT R V <5" ----------------------------------------------------------------------------------------- 30,41 1F LUMENS ----------------------------------------------------------------------------------------- 4" APERTURE DOWNLIGHT 2800 SPECTRUM LIGHTING SGEF4LEDOS-45L-30K-DS10-1 / DE WIDE DISTRIBUTION LED - DELIVERED 42 3000 80 DR DIM10 1 42 MVOLT R LG <5" FC4223OS-SG-SO - 30,41 1F FLUSH LENS LUMENS ------------------------------------------------------------------------- 6" APERTURE DOWNLIGHT 1900 SPECTRUM LIGHTING S_G_ DF6LEDFX-30t: 30K-DX / DF FRESNEL LENS SHIELDING LED - DELIVERED DELIVERED 25 3000 80 DR SW 1 25 MVOLT R DW <5" _H_ _T_IN_G 9,30 1F DEAD FRONT SHOWER TRIM LUMENS ---------------------------------------------------------- -------------------- 6" LED DOWNLIGHT 1800 PRESCOLITE LC6SL-6LCSL-18L-30K-8-WT DS WIDE DISTRIBUTION LED - DELIVERED 22 3000 80 DR DIM10 1 22 MVOLT R V <8" ----------------------------------------------------------------------------------------- 30,41 1F LUMENS ----------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- 4' STRIPLIGHT 5100 COLUMBIA LCL-4-40-ML: E_U FC LENSED SHIELDING LED - DELIVERED 42 4000 80 DR SW 1 42 MVOLT SUSP ES - 36 1C LUMENS 8' STRIPLIGHT 10000 COLUMBIA LCL_8-40-ML: E_U FD LENSED SHIELDING LED - DELIVERED 84 4000 80 DR SW 1 84 MVOLT SUSP ES - 36 1C LUMENS-------------------------------------------------------------------- 4' WALL MOUNT w/ INTEGRAL 3000 COLUMBIA LBIL-4-30-LW-I:-U-US FH OCCUPANCY SENSOR LED - DELIVERED 24 3000 80 DR DIM10 1 24 MVOLT S W - ---------------------------------- ---------------------------------------------- 28,55 1C LINEAR REFRACTIVE PATTERN LENS LUMENS ----------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------- 4' WALL MOUNT 4000 COLUMBIA LXEN4-40-LW-RFA-EU JB POLYCARBONATE LENS LED - DELIVERED 37 4000 80 DR SW 1 37 120 S W - 9 1C WET LOCATION LISTED LUMENS --------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------- 8' 6" L X 1.2" W X 1.2" H LINEAR LED UPLIGHT 300 4 4 WINONA WSL107W-LLP-8FT6-100ADJ-30DEG/ LA 30 DEGREE DISTRIBUTION LED - DELIVERED WATTS 3500 80 DR DIM10 AR WATTS 24VDC S SPEC - ---------------------------------------------------- - - ------------ LLP5A-35K-24--'XX' 9,24,27 1J,3,4 ADJUSTABLE MOUNT; WET LOCATION LUMENS PER FT. PER FT. PER FT. 1.25" WIDE LINEAR UPLIGHT 650 11 11 LUMINII KXL20-30K-H0-F-F-•SA-PS010V LB INDIRECT DISTRIBUTION LED - DELIVERED WATTS 3000 80 DR DIM10 AR WATTS 24VDC S SPEC - 24 11,3,4 FROSTED SHIELDING LUMENS PER FT. PER FT. PER FT. 4" RECESSED LINEAR 725 7 7 FINELITE HP4R-"XX"-H-830-120-SC LD DIRECT DISTRIBUTION LED - DELIVERED WATTS 3000 80 DR DIM10 AR WATTS 120 R LG <5" ----------------- ------------------------------- - ----------------------- 24 1G,3,4 FLUSH FROSTED DIFFUSER LUMENS PER FT. PER FT. PER FT. ----------------------------------------------------------------------------------------- 1" SQUARE PROFILE LINEAR 400 7 7 LUMINII K45M= LENGTH*-30K-VHO-F-F- LW FROSTED SHIELDING; 45 DEG ANGLE HSG. LED - DELIVERED WATTS 3000 80 DR DIM10 AR WATTS 120/24 S SPEC - -------------------------------------------- ------------------------ WH-PS010V 24 11,3,4 WHITE FINISH LUMENS PER FT. PER FT. PER FT. ------------------------------------------------------------- ----------------------- 0.7" W x 39"L SURFACE MOUNT LINEAR 85 LUMINII LL30-A-NC-NC-4-PSV / LV AMBER LEDs LED - DELIVERED 10 615 NM - DR SW 1 10 120/24 S W - ------------------------------------------------- ------------------------- SL7-39-F-SA-MC-SL7-A 1 L,3,4 WHITE FROSTED LENS LUMENS ------------------------------------------------------- ----------------- 1.5" SQUARE CONTINUOUS LINEAR 300 7 7 LUMINII K-"-3UK-LU-F-SI1%I*'r�-BZ-PSU"IUV LX FROSTED SHIELDING LED - DELIVERED WATTS 2200 80 DR DIM10 AR WATTS 120/24 S SPEC - ------------------------------------------ - --------------------------------------------- 24 10,4 BRONZE FINISH LUMENS PER FT. PER FT. PER FT. ------------------------------------------------------- — -------------------------------- 1" SQUARE PROFILE LINEAR 400 7 7 LUMINII K45M= LENGTH'_ 301<-VHO-F_ BZ- LY FROSTED SHIELDING; 45 DEG ANGLE HSG. LED - DELIVERED WATTS 3000 80 DR DIM10 AR WATTS 120/24 S SPEC - F-PS010V 24 11,3,4 BRONZE FINISH LUMENS PER FT. PER FT. I PER FT. --------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- 5" DIA X 0.5"MAX H SURFACE DOWNLIGHT 650 LIGHTOLIER S5R_8_30K-7 OA WET LOCATION LISTED LED - DELIVERED 10 3000K 80 DR DIM10 1 10 120 S V - 9,49 1F FROSTED PRISMATIC LENS SHIELDING LUMENS 4" APERTURE DOWNLIGHT 2800 SPECTRUM LIGHTING SGEF4LEDOS-45L-30K-DS10-1 / OB WIDE DISTRIBUTION LED - DELIVERED 42 3000K 80 DR DIM10 1 42 120 R V <5" FC42230S_SG_•SO_WL 9,41 1F FLUSH LENS - WET LISTED LUMENS 15"W X 12"D WALLPACK 2800 HOLOPHANE HLWPC2-P10-30I4,12-TFTM OD FORWARD THROW DISTRIBUTION LED - DELIVERED 28 3000 80 DR SW 1 28 120 S W - 28 1M LUMENS ------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- 19"DIAX 14"H DECORATIVE PENDANT A -LAMP CIRCA AH 5216 GM P1 SINGLE SHADE; GUNMETAL FINISH LED 2 LED RETROFIT 5 2800 80 - - 10 120 SUSP V - 2,5,6 FROSTED GLASS SHEILDING E26 BASE ---------------------------------------------------------------------------------------- 10" DIA X 23" H DECORATIVE PENDANT A -LAMP VISUAL_ COMFORT T TOB 5159HAB-WG P3 HAND RUBBED ANTIQUE BRASS LED 3 LED RETROFIT 5 2800 80 - 15 120 SUSP V - 2,5,6 E26 BASE ----------------------------------------------------------------------------------------- 28" DIA X 25" H DECORATIVE PENDANT CANDELABRA VISUAL_ COMFORT CHC 2187 AI P6 AGED IRON LED 4 LED RETROFIT 6 2800 80 - - - 24 120 SUSP DW - 2,5,7 E12 BASE ----------------------------------------------------------------------------------------- 14" DIA X 18" H DECORATIVE PENDANT A -LAMP VISUAL COMFORT TOB 5063BZ/H,AB-WG P7 BRONZE WITH ANTIQUE BRASS LED 2 LED RETROFIT 5 2800 80 - - 10 120 SUSP DW - -------------- -------------------------------------------- -------------------------------- 2,5,6 E26 BASE 15" DIA X 25" H DECORATIVE PENDANT CANDELABRA VISUAL COMFORT AH 5210GM P8 GUN METAL LED 3 LED RETROFIT 6 2800 80 - - - 18 120 SUSP DW - ----------------------------------------------------------------------------------------- 2,5,7 E12 BASE ---------------------------------------------------------------------------------------- 11"DIA X 13" H DECORATIVE PENDANT A -LAMP VISUAL COMFORT TOB 5226BZ/G2-CG P9 BRONZE WITH CLEAR GLASS LED 1 LED RETROFIT 5 2800 80 - - - 5 120 SUSP DW -------------- --------------------------------------------------------- ------------------- 2,5,6 E26 BASE ----------------------------------------------------------------------------------------- 50" DIA X 53" H DECORATIVE PENDANT CANDELABRA VISUAL COMFORT CHC 5199AI P10 AGED IRON LED 20 LED RETROFIT 6 2800 80 - - 120 120 SUSP DW 2,5,7 E12 BASE 24" DIA X 28" H DECORATIVE PENDANT CANDELABRA VISUAL COMFORT CHC 2535AI P11 AGED IRON LED 6 LED RETROFIT 6 2800 80 - - 36 120 SUSP DW - ------------------------------------------ - ---------------------- 2,5,7 E12 BASE ----------------------------------------------------------------------------------------- 29" DIA X 27" H DECORATIVE PENDANT A -LAMP VISUAL COMFORT CHC 5157MBK/G P12 MATTE BLACK LED 1 LED RETROFIT 23 2800 80 - - - 23 120 SUSP V - -------------- ----------------------------------------------------------------------- 2,8,10 E26BASE ----------------------------------------------------------------------------------------- 18" DIA X 13"H DECORATIVE PENDANT CANDELABRA CURREY AND COMPANY FANTINE CHANDELIER, SMALL 9759 P13 PYRITE BRONZE / RAJ MIRROR FINISH LED 4 LED RETROFIT 6 2800 80 - - 24 120 SUSP DW - -------------------- ----- - ------------------------- 2,5,7 E12 BASE 25" DIA X 15" H DECORATIVE PENDANT A -LAMP VISUAL COMFORT SK 5536AII-L P14 AGED IRON FINISH AND LINEN SHADE LED 4 LED RETROFIT 5 2800 80 - - - 20 120 SUSP LG ------------------------------------------ ------------------ 2,5,6 E26 BASE 12" DIA X 17" H DECORATIVE PENDANT A -LAMP VISUAL COMFORT TOB 5012HAB P15 HAND RUBBED ANTIQUE BRASS LED 1 LED RETROFIT 5 2800 80 - - - 5 120 SUSP V - 2,5,6 E26BASE -------------------------------------------------------- 34" DIA X 36"H DECORATIVE PENDANT CANDELABRA CURREY AND COMPANY OLIVERI CHANDELIER,9000-0277 P16 PYRITE BRONZE / RAJ MIRROR FINISH LED 6 LED RETROFIT 6 2800 80 - - - 36 120 SUSP DW - ---------------------------- - - - -------------------- 2,5,7 E12 BASE 12" DIA X 17" H DECORATIVE PENDANT A -LAMP VISUAL COMFORT TOB 50121BZ P17 ANTIQUE NICKEL LED 1 LED RETROFIT 5 2800 80 - - - 5 120 SUSP DW - 2,5,6 E26 BASE 17" DIA X 5"H DECORATIVE FLUSH MOUNT CANDELABRA VISUAL COMFORT AH 4015GM/C:G-FG P18 GUN METAL, CLEAR GLASS LED 3 LED RETROFIT 6 2800 80 - - - 18 120 SUSP V - -------------------------------------- - ------------------ 2,5,9 E26BASE ------------------------------------------------------------------------ 20" DIA X 8" H DECORATIVE FLUSH MOUNT CANDELABRA CIRCA KS 4065SB-CRE P19 SOFT BRASS FINISH, CREAM GLASS LED 3 LED RETROFIT 6 2800 80 - - - 18 120 SUSP V - 2,5,7 E12BASE ---------------------------------------------------------- 15" DIAX 10" H DECORATIVE SEMI FLUSH A -LAMP MINKA LAVERY 4942-570 P20 1 DARK NOBLE BRONZE; ETCHED WHITE GLASS LED 3 LED RETROFIT 6 2800 80 - - - 18 120 S V - -------------- ------------------------------------------------------------------------ 2,5,6 E26 BASE ------------------------------------------------------------------------ 40" W X 20"D X 35"H DECORATIVE PENDANT CANDELABRA CURREY AND COMPANY 9000-0289 P21 LED 6 LED RETROFIT 6 2800 80 - - 36 120 SUSP DW - 2,5,7 E12 BASE - ------ --------------------- -------------- 3" x 4.5" LINE VOLTAGE TRACK HEAD 1200 HALO L-805-SML-NF-930-P TA 25* BEAM SPREAD LED 1 DELIVERED 8 3000 80 DR ELV AR 8 120 S TRACK - ---------- -- --- 1 F,3 WHITE FINISH CBCP 4' LINE VOLTAGE TRACK, SINGLE CIRCUIT HALO L651 P T1 WHITE FINISH - - - - - - DR ELV AR - 120 S LG 24 1F,3 r'SUMMIT SMITH DEVELOPMENT 241 N, Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D MM�7F1 CONSTRUCTION SERVICES 889 E, Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 0 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & 0 DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 �llil llll// / ,�., 0pHEf7. No. 0033339 44/ C O O � U a o L C/) `W / , -F, W O �1— U) ^^O a �W V C U O^ W i C-0 U C r O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LIGHTING SCHEDULES s U Q Sheet Number: C_ U N CU aD E600 i7 0 21a MAW LIGHT FIXTURE SCHEDULE CONTINUED FROM E600 R LLI Z m O ry 0 I O NI LLI FI CD LLI CU U 0 -2 ca = NI 0) O O c a� E U 0 0 LU 0 N W LIGHT FIXTURE SCHEDULE FIXTURE LIGHT SOURCE BALLASTS/DRIVERS INPUT WATTS VOLT MOUNT SURFACE TYPE FIXTURE DEPTH FIXTURE SPECIFICATION AND ACCEPTABLE MANUFACTURERS OPTIONS SEE NOTE ID DESCRIPTION TYPE NO. DESCRIPTION WATTS K CRI (MIN.) TYPE CONTROL NO. MANUFACTURER CATALOG SERIES 16" DIA X 6" H DECORATIVE SEMI FLUSH A -LAMP MINKA LAVERY 840-102 U1 HARVARD COURT BRONZE WITH PEWTER LED 3 LED RETROFIT 5 2800 80 - - - 15 120 S DW - 2,5,6 ETCHED OPAL GLASS E26 BASE 24" W X 7" H DECORATIVE VANITY SCONCE A -LAMP MINKA LAVERY 4533-267B U4 DARK BRUSHED BRONZE LED 3 LED RETROFIT 5 2800 80 - - - 15 120 W V 2,5,6 ETCHED OPAL GLASS E26 BASE -------------------------------------------------------------- ----------------------- ---------------------------------------------------------------- ----------------------------------------------------------------- ---------------------- ----------------------- 16" H X 4" W DECORATIVE WALL SCONCE ROUND ARTICOLO LUMI LARGE: WALL SCONCE W1 ARTICOLO BLACK FINISH LED 1 LED RETROFIT 6 2800 80 - - - 6 120 W V - ---------------------------------------------------------------------------------- 2,5,11 GREY / GREY SHADE E12 BASE 18" H X 4.5"W XDECORATIVE WALL SCONCE CANDELABRA VISUAL COMFORT CHID11561AB-WG W2 ANTIQUE BURNISHED BRASS LED 1 LED RETROFIT 6 2800 80 - - - 6 120 W V - -------------------------------------------- - - - - - - - - - - - -- - - - - - - - - - - - - 2,5,7 E12BASE ------------------------------------------------------------------- 26" H X 17" W DECORATIVE WALL SCONCE A19 CURREY AND COMPANY BOLEBROOK WALL SCONCE 5910 W3 GOLD LEAF BLACK FINISH LED 1 LED RETROFIT 15 2800 80 - - - 15 120 W V - --------------------------- - - •---------------------- 2,5,12 GU24 BASE 12" H X 8" W DECORATIVE WALL SCONCE CANDELABRA CIRCA KS2065SB-CRE W4 LOFT RRACC / CREAM TINTED rI ACC _.. _.... _ . _.._ ......... _ . I P:n _-- 9 - 1 Fr) RETROFIT -__ .._..._... 6 _ 9RM An - _ _ 19 _ 19(1 1A/ V _ 9 F 7 , E12 BASE ------------------------------------------------------------ 13" H X 5" W X 4" D DECORATIVE WALL SCONCE CANDELABRA FEISS WB11355ANBZ W5 ANTIQUE BRONZE LED 1 LED RETROFIT 6 2800 80 - - - 6 120 W V ------------------ ------------------------------------- ----------------------- 2,5,7 E12BASE ------------------------------------------------------------------- 11" H X 14"W X 8" D CANDELABRA CURREY AND COMPANY FANTINE WALL SCONCE - 5193 W6 PYRITE BRONZE / RAJ MIRROR FINISH LED 2 LED RETROFIT 6 2800 80 - - 12 120 W V 2,5,7 E12BASE -------------- ---------------------------------------------- 24" W X 7.511 D X 2" H ART LIGHT 400 REVELITE AL-1-24-BZ-R-D-H WB BRONZE FINISH LED - DELIVERED 5 3000 80 DR DIM10 1 5 120 W V ---------------- - --------------------------------- ----------------------- 2 LUMENS------------------------------------------------------------------- 24" X 5" WALL VANITY SCONCE CANDELABRA CIRCA SS 2014BZ-FG WE BRONZE FINISH LED 2 LED RETROFIT 6 2800 80 - - 12 120 W V 2,5,9 E26 BASE -------------------------------------------------------------------------------------------- EXIT SIGN - SINGLE FACE LITHONIA EDG-1-G XF EDGE LIT TYPE LED IN UNIT 3 - - - - 3 MVOLT S V - 61 1S UNIVERSAL MOUNTING ----------------------------------------------------------------------------------------- EXIT SIGN - DOUBLE FACE LITHONIA EDG-2-G XG EDGE LIT TYPE LED - IN UNIT 3 - - - - - 3 MVOLT S V - ---------------- ---------------------------------------- --------------------------- 61 1S UNIVERSALMOUNTING ---------------------------------------------------------------------------------------- EXIT SIGN K- SINGLE FACE LITHONIA ---------------- --- - ------------------ WLTE-W-1-G - -------- xK DIE CAST HOUSING; WET LOCATION LED - IN UNI 1 3 - - - - 3 IVIVUL 1 S V - 9,61 10 UNIVERSAL MOUNTING ----------------------------------------------------------------------------------------- 2-HEAD EMERGENCY BATTERY UNIT LITHONIA ELM2L XS SELF DIAGNOSTICS LED - IN UNIT 3 - - - - 3 MVOLT S V - 66 1S STANDARD OUTPUT ---------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------- --------------------------------------------------------------------------- ------------ NOTE: SEE SPECIFICATION SECTIONS 26 50 00 FOR ADDITIONAL INFORMATION REGARDING LIGHTING FIXTURE AND INSTALLATION REQUIREMENTS. PROVIDE OPTIONS AND ACCESSORIES REFERENCED BY THE COLUMN TITLED "OPTIONS". RAKIII=TIRR EPTI QWALRA=CT PEQIIAUPKIT A8ALALL IE� ANIDFFATIRESIKnCATEDCEPTRI F =I . ACA MANIPArTI IPAIT hTTWI= PNr) ORAFTR1r: PEPvPKr= THIITDIMITAAf1JES PEEF1MAC QCE QEL ABBREVIATIONS: AR = AS REQUIRED DR = DRIVER GRID = GRADE PD = PENDANT SUSP = SUSPENDED BL = BI-LEVEL SWITCHING DW = DRYWALL H = HID PL = PLASTER SW = SWITCHING CAB = UNDERCABINET ELV = ELECTRONIC LOW VOLTAGE DIMMING HAL = HALOGEN PS = PULSE START T = CERAMIC/GLASS TILE CL = CLEAR EM = EMERGENCY HBF = HIGH BALLAST FACTOR R = RECESS TW = TUNABLE WHITE LED DALI = ADDRESSABLE, DIMMING <1-100% ES = EXPOSED STRUCTURE I = INCANDESCENT RGB = RED, GREEN, BLUE LEDs V = VARIES DMO = LED DIMMING 0-10V, 0 -100% ET = ELECTRONIC BALLAST LBF = LOW BALLAST FACTOR RM = REMOTE W = WALL MOUNTED DM1 = LED DIMMING 0-10V, 1 -100% F = FLUORESCENT LG = LAY -IN GRID S = SURFACE WD = WOOD DM5 = LED DIMMING 0-1OV, 5 -100% FD1 = FLUORESCENT DIMMING 1-100% MLV = MAGNETIC LOW VOLTAGE DIMMING SPEC = SPECIAL XFMR = TRANSFORMER DM10 = LED DIMMING 0-10V, 10 -100% FD5 = FLUORESCENT DIMMING 5-100% NBF = NORMAL BALLAST FACTOR ST = STANDARD DMW = DIM TO WARM LED FD10 = FLUORESCENT DIMMING 10-100% OT = OTHER STN = STONE DMX = ADDRESSABLE, DIMMING <1-100% OPTIONS: 1 = POST PAINTED FINISH 21 = FURNISH WITH AIR HANDLING CAPABILITY 41 = MATTE DIFFUSE LOW IRIDESCENT REFL. 61 = FURNISH WITH UNIVERSAL ARROWS AND GREEN STENCIL FACE 2 = REGRESSED ALUMINUM DOOR FRAME 22 = FURNISH WITH WIRE GUARD 42 = FURNISH WITH SYMMETRICAL REFLECTOR 62 = FURNISH WITH FIELD ADJUSTABLE CHEVRONS 3 = FLAT STEEL DOOR FRAME 23 = FURNISH WITH ENDCAPS 43 = FURNISH WITH ASYMMETRICAL REFLECTOR 63 = FURNISH WITH MIRRORED BACKGROUND 4 = FLAT ALUMINUM DOOR FRAME - MITERED CORNERS 24 = FURNISH IN LENGTH AS SHOWN 44 = FURNISH WITH TOP AND BOTTOM LENS 64 = FURNISH WITH INTEGRAL BATTERY 5 = STAINLESS STEEL TRIM AND DOOR FRAME 25 = FURNISH WITH SOLID FRONT 45 = FURNISH WITH LOUVER 65 = FURNISH WITH INTEGRAL HIGH CAPACITY BATTERY (FOR REMOTE HEADS) 6 = FURNISH WITH SPRING LOADED LATCHES 26 = FURNISH WITH DUST COVER 46 = FURNISH WITH PERFORATED DIFFUSER 66 = FURNISH WITH SELF DIAGNOSTICS 7 = FURNISH WITH HINGED DOOR 27 = CUSTOM FINISH - SELECTION TBD 47 = FURNISH WITH EGGCRATE LOUVER 67 = FURNISH WITH AUXILIARY EMERGENCY BATTERY BALLAST/DRIVER 8 = DAMP LOCATION CONSTRUCTION 28 = STANDARD FINISH - SELECTION TBD 48 = FURNISH WITH SOFTENING LENS 68 = SPARE 9 = WET LOCATION CONSTRUCTION 29 = FURNISH WITH HOUSE SIDE SHIELD 49 = FURNISH WITH PRISMATIC LENS 69 = SPARE 10 = IP65 RATING 30 = FURNISH WITH MVOLT 50 = FURNISH WITH LINEAR SPREAD LENS 70 = SPARE 11 = IP66 RATING 31 = SPARE 51 = FURNISH WITH SPREAD LENS 71 = FURNISH WITH ANTI -MICROBIAL FINISH 12 = IP67 RATING 32 = SPARE 52 = SPARE 72 = CERTIFIED FOR MIL-STD461F 13 = NEIVIA 4X RA I ED 33 = FURNISH WITH CHAIN MOUNTING 53 = SPARE 73 = FURNISH WITH RF NOISE SUPPRESSORS (ADVANCE RIF-1) FOR EACH DRIVER 14 = IC RATING 34 = FURNISH WITH RIGID STEM MOUNTING 54 = FURNISH WITH ROCKER SWITCH 74 = FURNISH WITH ACRYLIC LENS WITH INTEGRAL RFI SHIELDING 15 = ADA COMPLIANT 35 = FURNISH WITH SWIVEL CANOPY 55 = FURNISH WITH INTEGRAL OCC. SENSOR 75 = FURNISH WITH LOW VOLTAGE CONTROL (LVC) 16 = DOUBLE GASKETED-LENS TO TRIM TO CEILING 36 = FURNISH WITH ADJUSTABLE AIRCRAFT CABLE MOUNTING 56 = FURNISH WITH INTEGRAL DAYLIGHT SENSOR 76 = SPARE 17 = TRIPLE GASKETED-LENS TO DOOR TO HOUSING TO CEILING 37 = FURNISH WITH ADJUSTABLE MOUNTING HARDWARE 57 = FURNISH WITH INTEGRAL PHOTOCELL 77 = SPARE 18 = FURNISH WITH TAMPER RESISTANT HARDWARE 38 = FURNISH WITH MANUFACTURER'S CUSTOM JUNCTION BOX 58 = FURNISH WITH REMOTE DRIVER 78 = SPARE 19 = SINGLE GASKETED-LENS TO TRIM 39 = FURNISH WITH RECESSED SLOPE ADAPTER 59 = SPARE 79 = SPARE 20 = SPARE 40 = SPARE 60 = SPARE 80 = SPARE GENERAL NOTES: 1. VERIFY CEILING T-BAR WIDTH (I.E. 9/16", 15/16", 1.5") WITH THE ARCHITECT/INTERIORS SPECIFICATION PRIOR TO ORDERING LAY -IN FIXTURES. 2. IN ALL INSULATED OR FIRE RATED CEILINGS, THE EC SHALL BE RESPONSIBLE FOR THE PROPER TENTING (OR FIRE BOXING) OF THE RECESSED FIXTURES. FOR PREFAB PRODUCTS REFER TO TENMAT OR SPECIALTY PRODUCTS AND INSULATION. 3. VERIFY DIMMING BALLAST/ DRIVER COMPATIBILITY WITH DIMMING CONTROL. 4. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT. 5. TO MEET SPECIFIED DELIVERED LUMEN PACKAGE PROVIDE PROGRAMMED DRIVER AS REQUIRED. 6. FIXTURE PERFORMANCE TOLERANCES: CCT +/- 200 DEGREES; DELIVERED LUMENS +/- 5%; ENERGY CONSUMPTION +/- 5%; BEAM SPREAD DISTRIBUTION +/- 5 DEGREES AND AS OUTLINED IN 26 50 00. 7. IF SUBMITTING A FIXTURE FOR APPROVAL AS AN EQUAL, PROVIDE CUT SHEET AND IES PHOTOMETRIC FILE PRIOR TO BIDDING. A WORKING SAMPLE OF THE FIXTURE MAY BE REQUIRED FOR APPROVAL BY THE A/E. LIGHT FIXTURE SCHEDULE NOTES: 1, MANUFACTURERS, PRODUCTS, AND DESCRIPTIONS LISTED IN THE LIGHTING FIXTURE SCHEDULE ARE THE BASIS OF DESIGN SPECIFICATION FOR EACH FIXTURE TYPE. EQUAL PRODUCTS WILL BE ENTERTAINED UNLESS OTHERWISE NOTED. ALL PROPOSED EQUAL PRODUCTS ARE REQUIRED TO MEET OR EXCEED ALL OF THE SPECIFICATION REQUIREMENTS LISTED IN THE LIGHTING FIXTURE SCHEDULE INCLUDING BUT NOT LIMITED TO: PRODUCT GRADE, LIGHT SOURCE TECHNOLOGY, CONTROL TECHNOLOGY, OPTICAL PERFORMANCE (DELIVERED LUMENS OR CBCP), DISTRIBUTION, FIXTURE ACCESSORIES, CONSTRUCTION, DIMENSIONS, MOUNTING, FINISH, ENERGY PERFORMANCE, AND LISTINGS/RATINGS. THE SPECIFIER HAS EVALUATED ALL OF THE MANUFACTURERS LISTED BELOW AND CONSIDERS THESE MANUFACTURERS TO BE OF A QUALITY THAT MEET GENERAL SPECIFICATION REQUIREMENTS FOR THE CATEGORY OF PRODUCT UNDER WHICH THEY ARE LISTED. ALTHOUGH MANUFACTURERS ARE LISTED BELOW IT DOES NOT ENSURE THAT THEY HAVE PRODUCTS THAT MEET ALL OF THE SPECIFICATION REQUIREMENTS FOR EACH FIXTURE TYPE. IT MEANS THAT THESE MANUFACTURERS HAVE ALREADY BEEN EVALUATED AND HAVE PRODUCTS THAT SHALL BE REVIEWED FOR APPLICABILITY AS EQUALS. MANUFACTURERS THAT ARE NOT LISTED BELOW WILL REQUIRE A WORKING SAMPLE FOR SPECIFIER TO REVIEW IN ORDER TO BE EVALUATED FOR APPLICABILITY. THE BURDEN OF MEETING THE BASIS OF DESIGN SPECIFICATION IS ON THE DISTRIBUTOR QUOTING THE PROJECT. DETERMINATION OF EQUIVALENCY IS THE RESPONSIBILITY OF THE SPECIFIER. EVEN IF A PROPOSED EQUAL PRODUCT IS FROM ONE OF THE MANUFACTURERS LISTED BELOW, IF IT DOES NOT MEET THE BASIS OF DESIGN SPECIFICATION REQUIREMENTS THEN IT WILL BE REJECTED. THERE SHALL BE NO ADDITIONAL COST ASSOCIATED WITH REJECTION OF A FIXTURE NOT DEEMED EQUIVALENT BY THE SPECIFIER. A. ARCHITECTURAL GRADE TROFFERS -AXIS, FOCAL POINT, LEDALITE B. SPECIFICATION GRADE TROFFERS - FINELITE, MARK ARCHITECTURAL LIGHTING, PRUDENTIAL C. COMMERCIAL TROFFERS AND WHITEGOODS - COLUMBIA, CREE, DAYBRITE, DAY-O-LITE, HE WILLIAMS, LITHONIA, METALUX, MERCURY, PMC D. ARCHITECTURAL GRADE DOWNLIGHTS - EDISON PRICE, GOTHAM INCITO, IGUZZINI, INTENSE GRAVITY, KURT VERSEN, TECH ELEMENT, USA ILLUMINATION E. SPECIFICATION GRADE DOWNLIGHTS -AMERLUX, FOCAL POINT, GOTHAM EVO, INTENSE MX, JUNO-INDY, LEDRA ALPHABET, LIGHTOLIER, PORTFOLIO, PRESCOLITE LITEFRAME F. COMMERCIAL GRADE DOWNLIGHTS-CON-TECH, CONTRAST, CREE, GE, HALO COMMERCIAL, HE WILLIAMS, JUNO, LIGHTHEADED, LITON, LITHONIA, PEACHTREE, PRESCOLITE LITEFRAME COMMERCIAL, SPECTRUM, VANTAGE G. SPECIFICATION LINEAR -A-LIGHT, AMERLUX, ARCHITECTURAL LIGHTING WORKS, AXIS, CORONET, FINELITE, FOCAL POINT, GAMMALUX, LEDALITE, LITECONTROL, LUMINII, MARK ARCHITECTURAL LIGHTING, MERCURY, NEORAY, PEERLESS, PRUDENTIAL H. COMMERCIAL GRADE LINEAR- DAY-O-LIGHT, HE WILLIAMS, NULITE, PMC I. LOW VOLTAGE MODULAR LINEAR - EDGE LIGHTING, ELLIPTIPAR, IGUZZINI, LED LINEAR, LUMINII, WINONA J. LINE VOLTAGE MODULAR LINEAR - COLOR KINETICS, ECOSENSE, ELLIPTIPAR, FC LIGHTING, LUMENPULSE, WINONA K. ARCHITECTURAL GRADE EXTERIOR: ARCHITECTURAL AREA LIGHTING, BEGA, HESS, IGUZZINI, SELUX, TECH LIGHTING L. SPECIFICATION GRADE EXTERIOR: LEVEL 1: GARDCO, HYDREL, INVUE, KIM LIGHTING LEVEL 2: HUBBELL, LITHONIA, MCGRAW EDISON M. COMMERCIAL GRADE EXTERIOR - BEACON, LIGMAN, LUMARK, PHILIPS STONCO, RAB, VISIONAIRE N. HEALTHCARE SURGICAL TROFFER: ACUITY HEALTHCARE, AMICO, FAILSAFE, KENALL, KURTZON, LC DOANE, NEW STAR (W/MS OPTION) O. HEALTHCARE DOWNLIGHTS: EVERBRITE MEDLUX (MRI ONLY), FAILSAFE, HUBBELL HEALTHCARE, KENALL, KIRLIN, KURTZON, NEW STAR P. HEALTHCARE PATIENT ROOM: ACUITY HEALTHCARE, AMICO, FAILSAFE, FOCAL POINT, HE WILLIAMS, HUBBELL HEALTHCARE, KENALL, NEW STAR, VISA LIGHTING W. ARCHITECTURAL UNDERCABINET: AFX NOBLE PRO, FEELUX TUNELIGHT2, TECH LIGHTING AMBIANCE GLYDE, TECH LIGHTING UNILUME R. SPECIFICATION GRADE UNDERCABINET: COLUMBIA, DAYBRITE, FAILSAFE LITHONIA, PHILLIPS S. EXIT AND EMERGENCY -CHLORIDE, DUAL-LITE, EMERGI-LITE, EVENLITE, HE WILLIAMS, ISOLITE, LITHONIA, MULE, SURE-LITES 2. PROVIDE A BROKEN -OUT COST IN THE BID FORM FOR ALL SINGLE NAME SPECIFIED FIXTURE TYPES. 3. PROVIDE WITH ALL PARTS AND ACCESSORIES FOR A COMPLETE OPERATING INSTALLATION INCLUDING BUT NOT LIMITED TO: MOUNTING HARDWARE, POWER SUPPLIES, CONNECTOR CABLES, ETC. 4 PROVIDE AS A COMPLETE FIXTURE FROM THE MANUFACTURER. FIELD -CONSTRUCTED FIXTURES (TAPE, LENS, ENDCAPS, FEEDS, EXTRUSION SHIPPED AS SEPARATE PARTS) IS NOT APPROVED. '.SUMMIT SMITH DEVELOPMENT 241 N- Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD MWM=IrLF�l I.VIVJ I KUIr 1 IVIV jCKVIIiCj 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 ON DUCRING N HATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 I r-d@ringdu.col RD Project Number: 218092.00 G0 NNEcr ��,•,�pPHEf� �2 r!C'G�: / 1 ^d `\ No. 00333309 '�lV\ v ` i L-- f- pt Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LIGHTING SCHEDULES d J J U aD O O ti M N rn O N 5. FIXTURE SHALL BE LABELED FOR MAXIMUM WATTAGE OF 10 WATTS PER SOCKET. 6. PROVIDE WITH 10 WATT MAX, CLEAR FILAMENT STYLE A15 LAMP WITH MEDIUM E26 BASE. PROVIDE SYLVANIA CATALOG NO. LED4.5A15DIM827FILBL, OR EQUIVALENT. 7. PROVIDE WITH 10 WATT MAX, CLEAR FILAMENT STYLE B10 LAMP WITH CANDLEABRA E12 BASE. PROVIDE SYLVANIA CATALOG NO. LED5B10C/BENT/DIM/827/FILRP2, OR EQUIVALENT. 8. PROVIDE WITH 25 WATT MAX, A21 LAMP WITH E26 BASE. PROVIDE SYLVANIA CATALOG NO. LED23A21/DIM/0/827/U/B, OR EQUIVALENT. 9. PROVIDE WITH 10 WATT MAX, CLEAR FILIMANT STYLE B13 LAMP WITH MEDIUM E26 BASE. PROVIDE SYLVANIA CATALOG NO. LED6B13/BENT/DIM/827/RP, OR EQUIVALENT. 10. FIXTURE SHALL BE LABELED FOR MAXIMUM WATTAGE OF 25 WATTS PER SOCKET. 11. PROVIDE WITH 10 WATT MAX, CLEAR FILIMANT STYLE G16.5 LAMP WITH CANDELABRA E12 BASE. PROVIDE GE CATALOG NO. 41766, OR EQUIVALENT. An 11!'1/\\/1lll-\AIITII AC IA/ATT RAAV rl'l!1[rTt-1'1 AAl\1 AAA11 \AIITII ('r11,lA Il Afrr 1'11111\/1111'-IIA1 !\/1 (\ATA1 I�/'r A1I'\ AA!\r11A AlAn7/11A,1A111/rl l.lAll r'f, /1111-/�I 11\/A11-A IT U <Sheet Number: L U Cn ca Of N E601 d O LIGHTING CONTROL PANEL SCHEDULE - SECOND FLOOR PANEL DESIGNATION PANEL LOCATION RELAY NUMBER CIRCUIT CONTROLLED LOAD DESCRIPTION BRANCH SOURCE RELAY TYPE CONTROL SEQUENCE OF OPERATIONS SEE NOTE LOW VOLTAGE SWITCH PHOTOCELL TIMECLOCK BLINK WARNING CONTROL 1 NH/2-1-26 DINING 1030 DOWNLGIHTS N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 1 2 NU2-6-70 DINING 1030 PENDANT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 3 NU2-6-70 DINING 1030 PENDANT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 4 NL/2-6-72 DINING 1030 PENDANT N ON/OFF ON / OFF / OVFRRIDF - ON / nFF X 5 NU2-5-110 GRAND LOBBY 1001 PENDANTS N ON/OFF ON / OFF / OVERRIDE ON/OFF X 6 NU2-1-89 CORRIDOR C2009 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 7 NU2-1-89 CORRIDOR C2009 WALL N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 8 NU2-2-102 CORRIDOR C2008,C2010 CEILING N ON/OFF ON / OFF / OVERRIDE - ON / OFF X 9 NU2-2-102 CORRIDOR C2008,C2010 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 10 NU2-6-72 CORRIDOR C2007 CEILING N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 4 4 11 All /.f IVL/G-6-7L nn MMInnM norms IAIA 1 1 VVnRI VVR IJGVV/VVnLL AI IV nk. /'ram VIV/VI-I nkl I", I /1 Ines VIV/Vrr/VVERRIUC - IJIV/Vrr A LCP/2AL ELEC 2004 12 NU2-5-110 CORRIDOR C2003 CEIILNG N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 13 NU2-5-110 CORRIDOR C2003 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 14 NU2-5-110 ACTIVITY 2001 SEATING N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 15 NU2-5-110 ACTIVITY 2001 TV N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 16 NU2-5-110 CORRIDOR C2001 CEILING N ON/OFF ON / OFF / OVERRIDE - ON / OFF X 17 NU2-5-110 CORRIDOR C2001 ART LIGHTS N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 18 NU2-5-110 CORRIDOR C2002 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 19 NU2-5-110 CORRIDOR C2002 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 20 - SPACE - - - 21 - SPACE - - - - - - 22 - SPACE - - - - 23 - SPACE - - - - - 24 - SPACE - - - - - - 1 NU2-3-72 MC DINING 2061 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 NU2-3-72 MC DINING 2061 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 1 3 NU2-3-74 MC DINING 2061 DAYLIT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 1 4 NU2-3-74 CORRIDOR C2012, C2014 CEIILNG N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 5 NU2-4-110 CORRIDOR CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 6 NU2-4-110 CORRIDOR WALL N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 7 NU2-4-110 MC ACTIVITY 2093 DAYLIT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 1 LCP/2M(_ FI Fr 2096 8 NU2-4-112 MC ACTIVITY 2093 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 1 9 NU2-4-110 MC ACTIVITY 2093 UPLIGHT N ON/OFF ON / OFF / OVERRIDE - ON / OFF X 1 10 NU2-4-110 MC LOBBY 2100 N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 1 11 NU2-3-74 COUNTRY KITCHEN N ON / OFF ON / OFF / OVERRIDE - ON/OFF - 12 - SPACE - - - - - 13 - SPACE - - - - - 14 - SPACE - - - 15 - SPACE - - - - - 16 - SPACE - - - - - BRANCH SOURCE: N = NORMAL E = EMERGENCY C = CRITICAL LS = LIFE SAFETY E = 700 LEGALLY REQUIRED EMERGENCY S1 = 701 LEGALLY REQUIRED STANDBY S2 = 702 STANDBY LIGHTING CONTROL PANEL GENERAL NOTES: 1. PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE AND OPERA TING SYSTEM. 2. PROVIDE HIGH VOLTAGE BARRIERS AS NECESSARY TO SEPARATE DIFFERENT BRANCH SOURCES. 3. VERIFY ALL PROGRAMMING PARAMETERS WITH OWNER PRIOR TO FINAL COMMISSIONING. 4. REFER TO LOW VOLTAGE SWITCH STATION SCHEDULE FOR MORE INFORMATION. LIGHTING CONTROL PANEL SCHEDULE NOTES: 1. LOCAL 0-10V WALLBOX DIMMERS SHALL CONTROL DIMMING OF FIXTURES FED BY RELAY. SEE PLANS FOR LOCATIONS AND QUANTITIES. LIGHTING CONTROL PANEL SCHEDULE - FIRST FLOOR PANEL DESIGNATION PANEL LOCATION RELAY NUMBER CIRCUIT CONTROLLED LOAD DESCRIPTION BRANCH SOURCE RELAY TYPE CONTROL SEQUENCE OF OPERATIONS SEE NOTE LOW VOLTAGE SWITCH PHOTOCELL TIMECLOCK BLINK WARNING CONTROL 1 2 3 4 NU1-1-80 NU1-1-80 NU1-2-80 NU1-2-94 EXTERIOR LIGHTING CORRIDOR C1008 CEILING CORRIDOR C1008 WALL CORRIDOR C1007,C1011,C1012 CEILING N N N N ON/OFF ON / OFF ON/OFF ON/OFF - ON / OFF / OVERRIDE ON / OFF / OVERRIDE ON / OFF / OVERRIDE ON ONLY - - - OFF ONLY ON / OFF ON/OFF ON/OFF - X X X I 5 NU1-2-94 CORRIDOR C1007,C1011,C1012 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 6 NU1-6-45 CORRIDOR C1006 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 7 NU1-6-45 CORRIDOR C1006 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 8 NH/1-1-34 PASSAGE C1009 N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 9 NH/1-1-34 VESTIBULE C1010 N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 10 NH/1-1-34 WAIT STATION 1034 N ON/OFF ON / OFF / OVERRIDE - ON / OFF X 11 NH/1_1_3d FXHIR, KITCHEN 1011 N ON / OEF nN I nEF ! 0\/FPPIr1F - nN / OFF X 2 12 NU1-6-45 PRIVATE DINING 1032 N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 13 NU1-6-45 DINING 1030 DAYLIT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 14 NU1-6-47 DINING 1030 UPLIGHT N ON / OFF ON / OFF / OVERRIDE - ON / OFF X 2 15 NU1-6-48 DINING 1030 ACCENT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 16 NU1-6-48 FORMAL DINING 1031 PENDANT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 17 NH/1-1-34 FORMAL DINING 1031 DAYLIT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 18 NH/1-1-34 FORMAL DINING 1031 GENERAL N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 19 NU1-648 MAITRE D' 1028 N ON / OFF ON / OFF / OVERRIDE - ON/OFF X LCP/1AL ELEC 1042 20 NU1-6-48 CORRIDOR C1003, C1004, C1005 N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 21 NU1-6-48 LOUNGE 1073 ACCENT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 22 NH/1-1-34 LOUNGE 1073 DAYLIT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 23 NH/1-1-34 LOUNGE 1073 GENERAL N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 24 NU1-5-100 CLASSROOM 1026 PENDANT N ON / OFF ON / OFF / OVERRIDE - ON / OFF X 25 NU1-5-100 CLASSROOM 1023 PENDANT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 26 NH/1-1-34 CLASSROOM 1026 GENERAL N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 27 NH/1-1-34 CLASSROOM 1023 GENERAL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 28 NU1-5-100 GRAND LOBBY ACCENT & COVEVE N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 29 NU1-5-100 GRAND LOBBY 1001 UPLIGHT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 30 NU1-5-100 CONCIERGE 1016 N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 31 NU1-5-102 GRAND LOBBY 1001 GENERAL N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 32 NU1-5-102 VESTIBULE C1001 N ON / OFF ON / OFF / OVERRIDE - ON / OFF X 33 NU1-5-102 CORRIDOR 1002 WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 34 NU1-5-102 CORRIDOR 1002 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 35 NU1-5-102 BISTRO 1017 DAYLIT N ON / OFF ON / OFF / OVERRIDE - j ON/OFF X 2 36 NU1-5-102 BISTRO 1017 N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 37 NH/1-1-48 EXT LIGHTING N ON / OFF - ON ONLY OFF ONLY - 38 NH/1-1-50 EXT LIGHTING N ON/OFF - ON ONLY OFF ONLY - 39 I EM/1-1-17 PRIVATE DINING 1032 E ON/OFF ON/OFF/OVERRIDE - OFF ONLY X 1,2 40 EM/1-1-17 EXTERIOR EM E ON / OFF - ON ONLY OFF ONLY 1 NU1-3-80 MC DINING 1074 CEILING N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 2 NU1-3-80 MC DINING 1074 & CORRIDOR WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 3 NU1-3-80 MC DINING 1074 DAYLIT N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 2 4 NU1-3-80 CORRIDOR C103,C1015 CEILING N ON / OFF ON / OFF / OVERRIDE - ON/OFF X 5 NU1-3-80 COUNTRY KITCHEN 1092 N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 6 NU1-4-108 CORRIDOR CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 7 NU1-4-108 CORRIDOR WALL N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 8 NU1-4-108 MC ACTIVITY 1098 CEILING N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 LCP/1MC 1090 9 NU1-4-108 MC ACTIVITY 1098 DAYLIT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 2 10 NU1-4-108 LOBBY 1104 N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 11 - SPACE - - - - - 12 - SPACE - - - - - - 13 - SPACE - - - - - - 14 - SPACE - - - - - - 15 - SPACE - - - - - - 16 EM/1-1-18 EXTERIOR EM E ON/OFF - ON ONLY OFF ONLY BRANCH SOURCE: N = NORMAL E = EMERGENCY C = CRITICAL LS = LIFE SAFETY E = 700 LEGALLY REQUIRED EMERGENCY S1 = 701 LEGALLY REQUIRED STANDBY S2 = 702 STANDBY LIGHTING CONTROL PANEL GENERAL NOTES: 1. PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE AND OPERATING SYSTEM. 2. PROVIDE HIGH VOLTAGE BARRIERS AS NECESSARY TO SEPARATE DIFFERENT BRANCH SOURCES. 3. VERIFY ALL PROGRAMMING PARAMETERS WITH OWNER PRIOR TO FINAL COMMISSIONING. 4. REFER TO LOW VOLTAGE SWITCH STATION SCHEDULE FOR MORE INFORMATION. LIGHTING CONTROL PANEL SCHEDULE NOTES: 1. EGRESS FIXTURES SHOWN ON PLAN, FED BY RELAY, SHALL UTLIZE UL924 DEVICE. REFER TO DETAILS ON _ FOR WIRING DIAGRAM. EC SHALL DETERMINE COMPATIBLE TYPE(S). 2. LOCAL 0-10V WALLBOX DIMMERS SHALL CONTROL DIMMING OF FIXTURES FED BY RELAY. SEE PLANS FOR LOCATIONS AND QUANTITIES. LIGHTING CONTROL PANEL SCHEDULE - LOWER LEVEL PANEL DESIGNATION PANEL LOCATION RELAY NUMBER CIRCUIT CONTROLLED LOAD DESCRIPTION BRANCH RELAY SOURCE TYPE CONTROL SEQUENCE OF OPERATIONS SEE NOTE: LOW VOLTAGE SWITCH PHOTOCELL TIMECLOCK BLINK WARNING CONTROL 1 NUL-2-35 EXTERIOR N ON/OFF - ON ONLY OFF ONLY - 2 NUL-2-35 VESTIBULE PENDANT N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 3 NUL-2-35 CORRIDOR CEILING LIGHTS N ON/OFF ON / OFF / OVERRIDE - ON/OFF X 4 NUL-2-35 CORRIDOR WALL LIGHTS N ON/OFF ON / OFF / OVERRIDE - ON / OFF X 5 - SPACE - - - - - 6 - SPACE - - - - - 7 - SPACE - - - - - 8 EM/1-2-26 EXTERIOR LIGHTS E ON/OFF - ON ONLY OFF ONLY - BRANCH SOURCE: N = NORMAL E = EMERGENCY C = CRITICAL LS = LIFE SAFETY E = 700 LEGALLY REQUIRED EMERGENCY S1 = 701 LEGALLY REQUIRED STANDBY S2 = 702 STANDBY LIGHTING CONTROL PANEL GENERAL NOTES: 1. PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE AND OPERATING SYSTEM. PPVSUMMIT SMITH DEVELOPMENT 241 N, Rrna(iwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 0-2 DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.23601 r-d@ringdu.cor RD Project Number: 218092.00 ��4411111!/JJ HER,�� e No. 0033339 44/ ®, do s r � i � U 0 L C/) `D / i W o ^O �A ( J W (3) U 0 w U —0 C-0 CIO O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LIGHTING SCHEDULES i a CD O I` M N 0 N A 2. PROVIDE HIGH VOLTAGE BARRIERS AS NECESSARY TO SEPARATE DIFFERENT BRANCH SOURCES. 3. VERIFY ALL PROGRAMMING PARAMETERS WITH OWNER PRIOR TO FINAL COMMISSIONING. 4. REFER TO LOW VOLTAGE SWITCH STATION SCHEDULE FOR MORE INFORMATION. LIGHTING CONTROL PANEL SCHEDULE NOTES: C- U <Sheet Number: E602 cv N "SUMMIT SMITH DEVELOPMENT LOW VOLTAGE SWITCH STATION SCHEDULE - SECOND FLOOR RELAY CABINET DESIGNATION LOCATION BUTTON RELAYS CONTROLLED DESCRIPTIONS SEE NOTE 2.01 CORR C2009 a RC-6, RC-8, RC-10 CORRIDOR CEILING 1 b RC-7, RC-9, RC-11 CORRIDOR WALL 1 2.02 CORR C2009 a RC-6, RC-8, RC-10 CORRIDOR CEILING 1 b RC-7, RC-9, RC-11 CORRIDOR WALL 1 2.03 CORR C2008 a RC-6, RC-8, RC-10, RC-12 CORRIDOR CEILING 1 b RC-7, RC-9, RC-1 1, RC-13 CORRIDOR WALL 1 2.04 CORR C2003 a RC-10, RC-12 CORRIDOR CEILING 1 b RC-9, C-13 CORRIDOR WALL 1 LCP/2AL 2.05 ACTIVITY 2001 a RC-16 CORRIDOR CEILING 1 b RC-14 SEATING ON/OFF c RC-15 TV AREA ON/OFF 2.06 CORK C2001 a RC-16 CORRIDOR CEILING 1 b RC-17 CORRIDOR WALL 1 2.07 CORR C2002 a RC-16 ACTIVITY CORR CEILING 1 b RC-17 ACTIVITY ART LIGHTS 1 c RC-18 CORRIDOR CEILING 1 d RC-19 CORRIDOR WALL 1 2.08 CORR C2002 a RC-18 CORRIDOR CEILING 1 b RC-19 CORRIDOR WALL 1 2.23 CORK C2006 a RC-10, RC-12 CORRIDOR CEILING 1 b RC-9, C-13 CORRIDOR WALL 1 2.09 DINING 2061 a RD-2 DINING CEILING 1 b RD-1 DINING WALL 1 2.10 DINING 2061 a RD-2 DINING CEILING 1 b RD-3 DINING DAYLIT c RD-1 DINING WALL 1 2.11 DINING 2061 a RD-2 DINING CEILING 1 b RD-3 DINING DAYLIT c RD-1 DINING WALL 1 2.12 DINING 2061 a RD-2 DINING CEILING 1 b RD-3 DINING DAYLIT c RD-1 DINING WALL 1 2.13 COUNTRY KITCHEN 2082 a RD-11 KITCHEN ON/OFF 2.14 CORR 2014 a RD-4 CORRIDOR CEILING 1 b RD-1 CORRIDOR WALL 1 2.15 CORR 2014 a RD-4 CORRIDOR CEILING 1 b RD-1 CORRIDOR WALL 1 2.16 ACTIVITY 2093 a RD-5 CORRIDOR CEILING 1 b RD-6 CORRIDOR WALL 1 c RD-8 ACTIVITY 1 LCP/2MC 2.17 ACTIVITY 2093 a RD-5 CORRIDOR CEILING 1 b RD-6 CORRIDOR WALL 1 c RD-8 ACTIVITY 1 2.18 ACTIVITY 2093 a RD-5 CORRIDOR CEILING 1 b RD-6 CORRIDOR WALL 1 c RD-8 ACTIVITY 1 d RD-7 ACTIVITY DAYLIT e RD-8 ACTIVITY UPLIGHT 1 2.19 ACTIVITY 2093 a RD-5 CORRIDOR CEILING 1 b RD-6 CORRIDOR WALL 1 c RD-8 ACTIVITY 1 d RD-7 ACTIVITY DAYLIT e RD-8 ACTIVITY UPLIGHT 1 2.20 ACTIVITY 2093 a RD-5 CORRIDOR CEILING 1 b RD-6 CORRIDOR WALL 1 c RD-8 ACTIVITY 1 d RD-7 ACTIVITY DAYLIT e RD-8 ACTIVITY UPLIGHT 1 2.21 ACTIVITY 2093 a RD-5 CORRIDOR CEILING 1 b RD-6 CORRIDOR WALL 1 c RD-8 ACTIVITY 1 d RD-8 ACTIVITY UPLIGHT 1 2.22 MC LOBBY 2100 a RD-10 LOBBY 1 LOW VOLTAGE SWITCH STATION GENERAL NOTES: 1. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR MORE INFORMATION. 2. CONFIRM ALL SCENES/GROUPS WITH ARCHITECT AND OWNER DURING ON SITE PROGRAMMING. 3. DESCRIPTIONS ARE SUGGESTED BUTTON LABELS, OWNER TO CONFIRM SWITCH LABELS PRIOR TO ORDER RELEASE. LOW VOLTAGE SWITCH STATION SCHEDULE NOTES: 1. PROVIDE ON -ONLY OPERATION DURING BUSINESS HOURS. LOW VOLTAGE SWITCH STATION SCHEDULE - FIRST FLOOR RELAY CABINET DESIGNATION LOCATION BUTTON RELAYS CONTROLLED DESCRIPTIONS SEE NOTE 1.21 GRAND LOBBY 1001 a RA-32 VESTIBULE I 1 LCP/1AL 1.22 CORR 1002 a RA-33 CORRIDOR WALL 1 b RA-34 CORRIDOR CEILING 1 1.23 CORR 1002 a RA-33 CORRIDOR WALL 1 b RA-34 CORRIDOR CEILING 1 1.24 MC DINING 1074 a RB-1 DINING CEILING 1 b RB-2 DINING WALL 1.25 MC DINING 1074 a RB-1 DINING CEILING 1 b RB-2 DINING WALL c RB-3 DINING DAYLIT 1.26 MC DINING 1074 a RB-1 DINING CEILING 1 b RB-3 DINING DAYLIT c RB-2 DINING WALL 1 d RB-4 CORRIDOR CEILNG 1 1.27 MC DINING 1074 a RB-1 DINING CEILING 1 b RB-3 DINING DAYLIT c RB-2 DINING WALL 1 d RB-4 CORRIDOR CEILNG 1 1.28 COUNTRY KITCHEN 1092 a RB-5 COUNTRY KITCHEN ON/OFF 1.29 CORR a RB-6 CORRIDOR CEILING 1 b RB-7 CORRIDOR WALL 1 LCP/1 MC 1.30 CORR a RB-6 CORRIDOR CEILING 1 b RB-7 CORRIDOR WALL 1 1.31 ACTIVITY 1098 a RB-8 ACTIVITY CEILING 1 b RB-7 ACTIVITY WALL 1 1.32 ACTIVITY 1098 a RB-8 ACTIVITY CEILING 1 b RB-7 ACTIVITY WALL 1 c RB-9 ACTIVITY DAYLIT 1.33 ACTIVITY 1098 a RB-8 ACTIVITY CEILING 1 b RB-9 ACTIVITY DAYLIT c RB-6 CORRIDOR CEILING 1 d RB-7 CORRIDOR WALL 1 1.34 ACTIVITY 1098 a RB-8 ACTIVITY CEILING 1 b RB-9 ACTIVITY DAYLIT c RB-6 CORRIDOR CEILING 1 d RB-7 CORRIDOR WALL 1 1.37 LOBBY 1104 a RB-10 LOBBY 1 1.38 CORR C1013 a RB-4 CORRIDOR CEILING 1 1.39 CORR C1015 a RB-4 CORRIDOR CEILING 1 LCP/1AL 1.35 BISTRO a RA-35 DAYLIT b RA-36 GENERAL 1 LOW VOLTAGE SWITCH STATION GENERAL NOTES: 1. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR MORE INFORMATION. 2. CONFIRM ALL SCENES/GROUPS WITH ARCHITECT AND OWNER DURING ON SITE PROGRAMMING. 3. DESCRIPTIONS ARE SUGGESTED BUTTON LABELS, OWNER TO CONFIRM SWITCH LABELS PRIOR TO ORDER RELEASE. LOW VOLTAGE SWITCH STATION SCHEDULE NOTES: 1. PROVIDE ON -ONLY OPERATION DURING BUSINESS HOURS. LOW VOLTAGE SWITCH STATION SCHEDULE - LOWER LEVEL RELAY CABINET DESIGNATION LOCATION BUTTON RELAYS CONTROLLED DESCRIPTIONS SEE NOTE L.01 CORR C002 a RL-2 VESTIBULE 1 b RL-3 CORR CEILING 1 c RL-4 CORR WALL 1 LCP/LL L.02 CORR C002 a RL-2 VESTIBULE 1 b RL-3 CORR CEILING 1 c RL-4 CORR WALL 1 L.03 CORR C003 a RL-2 VESTIBULE 1 b RL-3 CORR CEILING 1 c RL-4 CORR WALL 1 LOW VOLTAGE SWITCH STATION GENERAL NOTES: 1. REFER TO LIGHTING CONTROL PANEL SCHEDULE FOR MORE INFORMATION. 2. CONFIRM ALL SCENES/GROUPS WITH ARCHITECT AND OWNER DURING ON SITE PROGRAMMING. 3. DESCRIPTIONS ARE SUGGESTED BUTTON LABELS, OWNER TO CONFIRM SWITCH LABELS PRIOR TO ORDER RELEASE. LOW VOLTAGE SWITCH STATION SCHEDULE NOTES: 1. PROVIDE ON -ONLY OPERATION DURING BUSINESS HOURS. LOW VOLTAGE SWITCH STATION SCHEDULE - FIRST FLOOR RELAY CABINET DESIGNATION LOCATION BUTTON RELAYS CONTROLLED DESCRIPTIONS SEE NOTE 1.01 CORR C1008 a RA-2, RA-4, RA-6 CORRIDOR CEILING 1 b RA-3, RA-5, RA-7 CORRIDOR WALL 1 1.02 CORR C1007 a RA-2, RA-4, RA-6 CORRIDOR CEILING 1 b RA-3, RA-5, RA-7 CORRIDOR WALL 1 1.03 CORR C1012 a RA-2, RA-4, RA-6 CORRIDOR CEILING 1 b RA-3, RA-5, RA-7 CORRIDOR WALL 1 LCP/1AL 1.04 CORR C1006 i a RA-2, RA-4, RA-6 CORRIDOR CEILING 1 b RA-3, RA-5, RA-7 CORRIDOR WALL 1 1.05 PASSAGE C1009 a RA-8 CORRIDOR ON/OFF 1.06 PASSAGE C1009 a RA-8 CORRIDOR ON/OFF 1.07 VESTIBULE C1010 a RA-9 VESTIBULE ON/OFF 1.08 PR. DINING 1032 a RA-12, RA-39 PRIVATE DINING ON/OFF j 1.09 EX. KITCHEN 1033 a RA-11 EXHIB. KITCHEN ON/OFF LCP/1AL AND LCP/2AL 1.10 WAIT STATION 1034 a RA-10 WAIT STATION 1 b RA-13 DINING DAYLIT ON/OFF c RA-14, RA-15 DINING ACCENT 1 d RB-1 DINING GENERAL ON/OFF e RB-2, RB-3, RB-4 DINING PENDANTS 1 LCP/1AL AND LCP/2AL 1.11 WAIT STATION 1034 a RA-10 WAIT STATION 1 b RA-13 DINING DAYLIT ON/OFF c RA-14, RA-15 DINING ACCENT 1 d RB-1 DINING GENERAL ON/OFF e RB-2, RB-3, RB-4 DINING PENDANTS 1 1.12 FORMAL DINING 1031 a RA-16 PENDANTS ON/OFF b RA-17 DAYLIT ON/OFF c RA-18 GENERAL ON/OFF 1.13 MAITRE D' 1028 a RA-19 MAITRE D' 1 b RA-10, RA-13, RA-14, RA-15, RBA, RB-2, RB-3, RB-4 DINING ON 1 1.14 CORR 1005 a RA-20 CORRIDOR 1 1.15 CORR 1005 a RA-20 CORRIDOR 1 LCP/1AL 1.16 CORR 1003 a RA-20 CORRIDOR 1 1.17 LOUNGE 1073 a RA-21 ACCENT 1 b RA-22 DAYLIT c RA-23 GENERAL 1.18 CLASSROOM 1026 a RA-24 PENDANTS b RA-26 DOWNLIGHTS 1.19 CLASSROOM 1023 a RA-25 PENDANTS b RA-27 DOWNLIGHTS LCP/1AL AND LCP/2AL 1.20 CONCIERGE 1016 a RB-5 PENDANTS 1 b RA-28 ACCENT & COVE 1 c RA-29 UPLIGHT 1 d RA-31 GRAND LOBBY 1 e RA-30 CONCIERGE 1 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 A I- I- _ -1 _ _ . _ _ _ _ _ _ _ ... _ _ . _ _ :1 _ vvepslle: WWW.summltsmlln.com Cm D ^iV1101 rx %.o 1 IU V JCRVI%iEJ 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 r-ax: 414-359-3U 7 U RIMS2 DIQX A 04 UCH TEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.cor RD Project Number: 218092.00 \\\�siiiirrrri G0 NNFcT ,t•�pQHER 4V %G 1 No. 0033339 I tV i t 1 O CD O � U W Q) L O (D W O U) O �W V ♦ � L_ V 2) O ll.l � U Co � O a = Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: LIGHTING SCHEDULES �I MAW C_ U Q Sheet Number: U Cn Cc6 E603 Y C ON Q SUMMIT SMITH DEVELOPMENT 241 N. Bmadwav PLUMBING EQUIPMENT SCHEDULE FEED FROM OCPD BRANCH WIRING MOTOR CONTROLLER DISCONNECT SWITCH CONNECTION REQUIREMENTS SEE NO. SERVING LOC. VOLT/ HP FLA KW NOTE PANEL CKT BRNH TYPE SIZE POLE NO. SIZE GRD COND GIRD FURN INST WIRE LOC. TYPE OPTIONS FURN INST WIRE LOC. OPTIONS NEMA TYPE OPTIONS MTG HEIGHT PHASE Y/N SIZE BY BY BY BY BY BY PCP-1 CIRCULATION PUMP WATER 1042 120/1 2/5 NU1-1 76 N CB 20 1 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 - 1,2 PCP-2 CIRCULATION PUMP WATER 1042 120/1 1/12 NU1-1 78 N CB 20 1 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 - 1,2 PEWC ELECTRIC WATER COOLER ALCOVE 120/1 0.5 SFP SFP N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - - - 2 PSP-"I SUMP rUivlr ELEV E1 SFP 2Uti%1 U.4 OS%1-L 43,45 US %B 15 L L "12 Y "I/2'I 12 P% El: EC IVV - - EC El: EC IVU - - 3 - 1,2 PSP-2 SUMP PUMP ELEV E2 SFP 208/1 0.4 OS/1-2 47,49 OS CB 15 2 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 - 1,2 PSP-3 SUMP PUMP ELEV E3 SFP 208/1 0.4 OS/1-1 16,18 OS CB 15 2 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 - 1,2 PWH-1 WATER HEATER WATER 1042 120/1 NU1-1 75 N CB 15 1 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 1 PWH-2 WATER HEATER WATER 1042 120/1 NU1-1 77 ! N CB 15 1 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 1 PWH-3 WATER HEATER ( WATER 1042 120/1 NU1-1 79 N I CB 15 1 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 1 PWH-4 WATER HEATER WATER 1042 120/1 NU1-1 81 N CB 15 1 2 12 Y 1/2" 12 PC EC EC NU - - EC EC EC NU - - 3 1 ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MFR = MANUFACTURER 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS SA =: SEE ARCHITECTURAL DETAILS LS = LIFE SAFETY BRANCH F = AMPERE RATED FUSES PC = PLUMBING CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONELINE DIAGRAM CR = CRITICAL CARE BRANCH OCPD = OVERCURRENT PROTECTIVE DEVICE MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD EQ = EQUIPMENT SYSTEM EC = ELECTRICAL CONTRACTOR MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF EIVI = EIVIERGGINI^i1 SISTEIVI FSEI^i = FOOD SERVICE EQUIP. CON I RAC I OR CS = CVIVIBIINATION 111_W4TRVLLER OV = VIN UN 1 FD = FUSIBLE DISC'VIVIINGCT ES = ESSENTIAL SYSTEM MC = MECHANICAL CONTRACTOR RVS = REDUCE VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION 13 = GFI RECEPTACLE 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNTED 14 = FED FROM UPSTREAM GFI BREAKER 3 = DIRECT CONNECTION 6 = WEATHERPROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNTED PLUMBING EQUIPMENT SCHEDULE NOTES: E.C. SHALL WIRE BE I AVEEN SUPPLY O V ERCURREN T PROTECTION DEVICE AND DISCONNECT SWITCH OR CONTROL PANEL. 2. E.C. SHALL WIRE BETWEEN DISCONNECT SWITCH AND EACH MOTOR. GENERAL EQUIPMENT SCHEDULE FEED FROM OCPD BRANCH WIRING MOTOR CONTROLLER DISCONNECT SWITCH CONNECTION REQUIREMENTS SEE NO. SERVING LOC. VOLT/ HP FLA KW NOTE PANEL CKT BRNH TYPE SIZE POLE NO. SIZE GRID COND GRID FURN INST WIRE LOC. TYPE OPTIONS FURN INST WIRE LOC. OPTIONS NEMA TYPE: OPTIONS MTG HEIGHT PHASE Y/N SIZE BY BY BY BY BY BY GFACP FIRE ALARM CONTROL PANEL ELEC 1029 120/1 SFP SFP EM CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - 2 - 3 GFIG FIREPIT IGNITION AL COURTYD 120/1 SFP SFP N CB 20 1 2 12 Y 1/211 12 - - - - - - - - - - 3 - 3 GFPI FIRE PANEL INTERFACE ELEC 1029 120/1 SFP SFP EM CB 20 1 2 12 Y 1/211 12 - - - - - - - - - - 2 - 3 GLCP LIGHTING CONTROL PANEL ELEC 1021 120/1 SFP SFP EM CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - 3 - GTCL TIMECLOCK STAFF 0032 120/1 SFP SFP N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - 2 - 3 TMP TEMP CONTROL PNL SFP 120/1 SFP SFP N CB 20 1 2 12 Y 1/2" 12 1 CMC1 COIL POWER CONTACTOR C/MC1 1093 120/1 0.05 OS EM CB 20 1 2 12 Y 1/21, 12 - - - - - - - - - - - - 3 - ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MFR =UC- MFR = MANUFACTURER 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS SA = SEE ARCHITECTURAL DETAILS LS = LIFE SAFETY BRANCH F = AMPERE RATED FUSES PC =UF- PC = PLUMBING CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONELINE DIAGRAM CR = CRITICAL CARE BRANCH OCPD = OVERCURRENT PROTECTIVE DEVICEMAN =UO- MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD EQ = EQUIPMENT SYSTEM EC = ELECTRICAL CONTRACTOR MAG =UE- MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF EM = EMERGENCY SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTORCS =UF- CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT ES = ESSENTIAL SYSTEM MC = MECHANICAL CONTRACTOR RVS =UM- RVS = REDUCE VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION 13 = GFI RECEPTACLE 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNTED 14 = FED FROM UPSTREAM GFI BREAKER 3 = DIRECT CONNECTION 6 = WEATHERPROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNTED GENERAL EQUIPMENT SCHEDULE NOTES: 1. REFERENCE MECHANICAL PLANS FOR FINAL LOCATION OF ALL TEMPERATURE CONTROL PANELS. PROVIDE (1) 120V normal power circuit from nearest normal power panel. F� W z M O ry 0 ry rn 1 0 N w I �I U C7 W M U 0 ca Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D N M O 7 LI CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-30 70 RING & 01- DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.col RD Project Number: 218092.00 0 N NF�T''', No. 0033339 o � t 1 O co � U W O L / -�--' W 0 ^O >-% V / CZ � (3) L_ CU 2) o W U —0 C-0 CIO O a = � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: POWER SCHEDULES Uj U N U <Sheet Number: U N Cc6 E61 0 4) Y C M TYPICAL EQUIPMENT SCHEDULE NO. SERVING LOC. VOLT/ PHASE HP FLA KW FEED FROM OCPD BRANCH WIRING MOTOR CONTROLLER DISCONNECT SWITCH CONNECTION REQUIREMENTS SEE NOTE PANEL CKT BRNH TYPE SIZE POLE NO. SIZE GRD /N COND GIRD SIZE FURN BY INST BY WIRE BY LOC. TYPE OPTIONS FURN BY INST BY WIRE BY LOC. OPTIONS NEMA TYPE OPTIONS MTG HEIGHT TDH DOOR HARDWARE SFP 12011 SFP SFP SFP CB 20 1 2 12 Y 112 12 - - - - - - - - - - - - 3 - - TDH2 VESTIBULE SLIDING DOOR VEST 1000 120/1 5 SFP SFP EM CB 20 1 2 12 Y 112 12 - - - - - - - - - - - - 3 - - TECR EMERGENCY CALL REPEATER SFP 120/1 - 0.1 SFP SFP EM CB 20 1 2 12 Y 1/2 12 - - - - - - - - - - - - - - TFP1 DINING/LOUNGE/LOBBY FIREPLACE LOUNGE 126 LOBBY 1001 120/1 1.5 SFP SFP N CB 20 1 2 12 Y 1/2 12 - - - - - - - - - - - - 3 - 1 TFP2 MC FIREPLACE MC ACTIVITY 208/3 10.1 SFP SFP N F 15 3 3 12 Y 1/2 12 - - - - - - - - - - - - 3 - 2 TRF REFRIGERATOR SFP 120/1 SFP SFP SFP CB 20 1 2 12 Y 1/2 12 - - - - - - - - - - - - 2,10 - - TUR UNDERCOUNTER REFRIGERATOR SFP 120/1 SFP SFP SFP CB 20 1 2 12 1 Y 1/2 12 - - - - - - - - - - - - 2,10 - - EWC ELECTRIC WATER COOLER SFP 12011 SFP SFP SFP CB 20 1 2 12 Y 1/2 12 - - - - - - - - - - - - 10 - - TRD RESDIENT WASHER SFP 120/1 #N/A SFP SFP SFP CB 20 1 2 12 Y 1/2 12 - - - - - - - - - - - - 10 - - TCD RESIDENT DRYER SFP 20811 #N/A SFP SFP SFP CB 30 2 2 10 Y 1/2 12 - - - - - - - - - - - - 10 - - TRW RESIDENT WASHER SFP 208/1 #N/A SFP SFP SFP CB 20 2 2 12 Y 1/2 12 - - - - - - - - - - - - 10 - - TCW RESIDENT WASHER SFP 208/1 #N/A SFP SFP SFP CB 30 2 2 10 Y 1/2 12 - - - - - - - - - - - - 10 - - ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MFR = MANUFACTURER 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS SA = SEE ARCHITECTURAL DETAILS LS = LIFE SAFETY BRANCH F = AMPERE RATED FUSES PC = PLUMBING CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONELINE: DIAGRAM CR = CRITICAL CARE BRANCH OCPD = OVERCURRENT PROTECTIVE DEVICE MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD EQ = EQUIPMENT SYSTEM EC = ELECTRICAL CONTRACTOR MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF EM = EMERGENCY SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT ES = ESSENTIAL SYSTEM MC = MECHANICAL CONTRACTOR RVS = REDUCE VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION 13 = GFI RECEPTACLE 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNTED 14 = FED FROM UPSTREAM GFI BREAKER 3 = DIRECT CONNECTION 6 = WEATHERPROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNTED TYPI['.Al F01 IIPMFNT .gr.HFni 11 F NnTFS- E.C. SHALL PROVIDE 120V UNSWITCHED CIRCUIT TO APPLIANCE JUNCTION BOX FOR HEAT MANAGEMENT SYSTEM, POWER VENT AND LED LIGHTING. 2• E.C. SHALL PROVIDE 15A RATED ON/OFF WALL SWITCH WITH (2) #12AWG & GND FROM HEATER WALL SWITCH BOX TO JUNCTION BOX ON THE UNIT. COORDINATE REQUIREMENTS WITH APPROVED FIREPLACE MANUAFCTURER. 3. E.C. SHALL PROVIDE NEMA 14-30R TYPE RECEPTACLE LLI z M O rn I 0 N U '.SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 111=01 A I MIM��G� CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 DING & +DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.col RD Project Number: 218092.00 0 N IV •�O?HER `C) �� c' co /Z �� , No. 0033335 ��` r 0 � r CU O co � U o L C/) 0 W 0 0 0 CU a L_ UCM L � O W U C-0 r O CU w _ � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: POWER SCHEDULES U ¢Sheet Number: v N fa E611 =3 Y C "SUMMIT SMITH f� LL! Z M O rnl O N LU F-I U CD LU /) CU 0 L CU U MECHANICAL EQUIPMENT SCHEDULE NO. SERVING LOC. VOLT/ PHASE HP FLA KW FEED FROM OCPD BRANCH WIRING MOTOR CONTROLLER DISCONNECT SWITCH CONNECTION REQUIREMENTS SEE NOTE PANEL CKT BRNH TYPE SIZE POLE NO. SIZE GRD Y/N COND GRD SIZE FURN BY INST BY WIRE BY LOC. TYPE OPTIONS FURN BY INST BY WIRE BY LOC. OPTIONS NEMA TYPE: OPTIONS MTG HEIGHT MBS-A BRANCH SELECTOR BOX SFP 208/1 .4 MCA SFP SFP SFP CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN - MC EC EC - 4 - - - - MSB-B BRANCH SELECTOR BOX SFP 208/1 .6 MCA SFP SFP SFP CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN - MC EC EC - 4 - - - - MBS-C BRANCH SELECTOR BOX SFP 208/1 .8 MCA SFP SFP SFP CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN - MC EC EC - 4 - - - - MBS-D BRANCH SELECTOR BOX SFP 208/1 .1 MCA SFP SFP SFP CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN - MC EC EC - 4 - - - - MBS-E BRANCH SELECTOR BOX SFP 208/1 .1 MCA SFP SFP SFP CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN - MC EC EC - 4 - - - - I MCU-1A VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 2,4,6 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-1 B VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 8,10,12 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-2A VRV CONDENSING UNIT AL ROOF 480/3 39.8 MCA OSH/1-1 2,4,6 OS CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-213 VRV CONDENSING UNIT AL ROOF 480/3 39.8 MCA OSH/1-1 8,1,012 OS CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-3A VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 14,16,18 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-36 VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 20,22,24 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-4A VRV CONDENSING UNIT AL ROOF 480/3 39.8 MCA NH/2-1 19,21,23 N CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-413 VRV CONDENSING UNIT AL ROOF 480/3 39.8 MCA NH/2-1 25,27,29 N CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-5A VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 31,33,35 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-5B VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 37,39,41 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-6A VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 1,3,5 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-613 VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-1 26,28,30 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-7A VRV CONDENSING UNIT AL ROOF 480/3 43.3 MCA NH/2-2 26,28,30 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-8A VRV CONDENSING UNIT AL ROOF 480/3 39.8 MCA NH/2-2 17,19,21 N CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-9A VRV CONDENSING UNIT MC ROOF 480/3 43.3 MCA NH/2-2 14,16,18 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC I WP 4 - - - - MCU-96 VRV CONDENSING UNIT MC ROOF #REF! 43.3 MCA NH/2-2 2,4,6 N CB 50 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-10 VRV CONDENSING UNIT MC ROOF 480/3 39.8 MCA NH/2-2 8,10,12 N CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-11 VRV CONDENSING UNIT MC ROOF 480/3 39.8 MCA NH/2-2 11,13,15 N CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - MCU-12A VRV CONDENSING UNIT MC ROOF 480/3 39.8 MCA OSH/1-1 1,3,5 OS CB 45 3 3 8 Y 1" 10 MC EC EC MAG HOA MC EC EC NU, WP 4 - - - - MCU-12B VRV CONDENSING UNIT MC ROOF 480/3 39.8 MCA OSH/1-1 7,9,11 OS CB 45 3 3 8 Y 1" 10 MC EC EC NU MAG HOA MC EC EC NU, WP 4 - - - - AA!`I II-I-1 ,rlvv.l / (:ARIKIGT I WIT I-1CATCD /.✓Ilv�, vlvll I I�r'\I �I♦ %/CCT rMl14 VLlll VVVV I ARl1/4 TVV/V 00 4 AArA GG.V IVIV(l 1tz IV mwm-1 IVI I/ I -I 4 Q F ,V,V Al Iv CR vl../ )r c.V 4 V Q V In IV V I 'VA" V/-i 1(1 IV AACD IYII I\ AACD IVII I\ C!` LV ni I vv AAAKI /vl/�Iv AACD IVII 1\ AACD IVII I\ C(` I...V All 1 Ivv A T - - - - MCUH-2 CABINET UNIT HEATER VEST C1001 480/3 22.3 MCA 15 NH/1-1 31,33,35 N CB 25 3 3 10 Y 3/4" 10 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MEWH-1 ELEC WALL HEATER S2 LOWER 480/1 8.7 MCA 4 NH/1-1 7,9 N CB 15 2 2 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MEWH-2 ELEC WALL HEATER S3 LOWER 480/1 8.7 MCA 4 NH/1-1 11,13 N CB 15 2 2 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MEWH-3 ELEC WALL HEATER S1 FIRST 480/1 8.7 MCA 4 NH/1-1 2,4,6 N CB 15 2 2 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MEWH-4 ELEC WALL HEATER S4 FIRST 480/1 8.7 MCA 4 NH/1-1 6,8 N CB 15 2 2 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MEWH-5 ELEC WALL HEATER S5 FIRST 480/1 8.7 MCA 4 NH/1-2 2,4 N CB 15 2 2 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MEWH-6 ELEC WALL HEATER S6 FIRST 480/1 8.7 MrA 4 NH/1-2 6.8 N CB 15 2 2 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MDOAS-1 DED OUTDOOR AIR UNIT ROOF -AL NORTH 480/3 69.3 MCA MDPH 14,16,18 N CB 90 3 3 3 Y 1-1/4" 8 MFR MFR EC OU VFD HOA MFR MFR EC NU, WP 4 - - - - MDOAS-1 FIELD POWERED GFI ROOF -AL NORTH 120/1 - NU2-3 90 N CB 20 2 2 12 Y 1/2" 12 - - - - - - - - - NU, WP - - - - MDOAS-2 DED OUTDOOR AIR UNIT ROOF - AL SOUTH 480/3 42 MCA MDPH 8,10,12 N CB 60 3 3 6 Y 1" 10 MFR MFR EC OU VFD HOA MFR MFR EC NU, WP 4 - - - MDOAS-2 FIELD POWERED GFI ROOF - AL SOUTH 120/1 - NU2-3 88 N CB 20 2 2 12 Y 1/2" 12 - - - - - - - - - NU, WP - - - - MDOAS-3 DED OUTDOOR AIR UNIT ROOF - MEM CARE 480/3 45.8 MCA MDPH 13,15,17 N CB 60 3 3 6 Y 1" 10 MFR MFR EC OU VFD HOA MFR MFR EC NU, WP 4 - - - - MDOAS-3 FIELD POWERED GFI ROOF - MEM CARE 120/1 - NU2-3 92 N CB 20 2 2 12 Y 1/2" 12 - - - - - - - - - NU, WP - - - - - MRTU-1A ROOFTOP UNIT ROOF 480/3 101.7 MCA MSB MSB N CB 110 3 - - - - - MFR MFR EC OU VFD HOA MFR MFR EC NU 4 - - - - MRTU-1A FIELD POWERED GFI ROOF 120/1 SFP SFP N CB 20 2 2 12 Y 1/2" 12 - - - - - - - - - NU, WP - - - - - MUH-1 UNIT HEATER 1042 208/3 14.6 MCA 5 LN/1-1 70,72,74 N CB 20 3 3 12 Y 1/2" 12 MFR MFR EC OU MAN MFR MFR EC NU 4 - - - - MVAV-1 VAV BOX 1035 277/1 1.1 NH/1-1 14 N CB 15 3 3 12 Y 1/2" 12 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-2 VAV BOX 1035 480/3 28.5 NH/1-1 16,18,20 N CB 50 3 3 8 Y 1" 10 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-3 VAV BOX 1035 277/1 5.5 NH/1-1 17 N CB 30 3 3 10 Y 3/4" 10 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-4 VAV BOX 1035 277/1 2.2 NH/1-1 19 N CB 15 3 3 12 Y 3/4" 12 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-5 VAV BOX 1034 277/1 2.2 NH/1-1 21 N CB 15 1 1 12 Y 3/4" 12 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-6 VAV BOX 1034 480/3 10.8 NH/1-1 22,24,26 N CB 20 3 3 12 Y 3/4" 12 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-7 VAV BOX 1028 480/3 10.8 NH/1-1 23,25,27 N CB 20 1 1 12 Y 1/2"' 12 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-8 VAV BOX 1028 277/1 1.1 NH/1-1 29 N CB 15 3 3 12 Y 1/2" 12 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVAV-9 VAV BOX 1021 480/3 12.7 NH/1-1 19,21,23 N CB 25 3 3 10 Y 3/4" 10 MC EC EC OU MAG HOA MFR MFR EC NU 4 - - - - MVRV-A VRV FAN COIL UNIT SFP 208/1 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-B VRV FAN COIL UNIT SFP 208/1 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-C VRV FAN COIL UNIT SFP 208/1 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-D VRV FAN COIL UNIT SFP 208/1 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-E VRV FAN COIL UNIT SFP 208/1 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-F VRV FAN COIL UNIT SFP 208/1 1.4 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-G VRV FAN COIL UNIT SFP 208/1 1.6 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-H VRV FAN COIL UNIT SFP 208/1 1.8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-1 VRV FAN COIL UNIT SFP 208/1 1.8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-J VRV FAN COIL UNIT SFP 208/1 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-K VRV FAN COIL UNIT SFP 20811 .8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-L VRV FAN COIL UNIT SFP 208/1 1.4 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-M VRV FAN COIL UNIT SFP 208/1 1.6 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-N VRV FAN COIL UNIT SFP 208/1 1.8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-O VRV FAN COIL UNIT SFP 208/1 1.8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" i 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-P VRV FAN COIL UNIT SFP 208/1 2.5 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-Q VRV FAN COIL UNIT SFP 208/1 2.8 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - MVRV-R VRV FAN COIL UNIT SFP 208/1 3.3 MCA SFP SFP N CB 15 2 2 12 Y 1/2" 12 MC EC EC OU MAN MC EC EC NU 4 - - - - DSS-1 DUCTLESS SPLIT SYSTEM (INDOOR) 2034 208/1 1 MCA NU2-6 91,93 N CB 15 2 2 12 Y 1/2" 12 MC EC EC NU MAG HOA MFR MFR EC NU 4 - - - - DSS-1 DUCTLESS SPLIT SYSTEM (OUTDOOR) ROOF 208/1 11.8 MCA NU2-6 95,97 N CB 20 2 2 12 Y 1/2" 12 MC EC EC NU MAG HOA MFR MFR EC NU 4 - - - - DSS-2 DUCTLESS SPLIT SYSTEM (INDOOR) 2016 208/1 1 MCA NU2-3 71,73 N CB 15 2 2 12 Y 1/2" 12 MC EC EC NU MAG HOA MFR MFR EC NU 4 - - - - DSS-2 DUCTLESS SPLIT SYSTEM (OUTDOOR) ROOF 208/1 11.8 MCA NU2-3 76,78 N CB 20 2 2 12 Y 1/2" 12 MC EC EC NU MAG HOA MFR MFR EC NU 4 - - - - MTCP-1 RTU-1 TEMP CNTRL PNL 2033 120/1 N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - - - - - - MTCP-2 DOAS-1 TEMP CNTRL PNL 2033 120/1 NU2-2 103 N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - - - - - - MTCP-3 DOAS-2 TEMP CNTRL PNL 2033 120/1 NU2-2 105 N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - - - - - - MTCP-4 DOAS-3 TEMP CNTRL PNL 1093 120/1 N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - - - - - - MTCP-5 VAV XFMR PNL WAIT STA 1028A 120/1 N CB 20 1 2 12 Y 1/2" 12 - - - - - - - - - - - - - - - ABBREVIATIONS: N = NORMAL BRANCH CB = AMPERE RATED CIRCUIT BREAKER MFR = MANUFACTURER 2SP = 2 SPEED MAGNETIC CONTROLLER SFS = SEE FOOD SERVICE PLANS SA = SEE ARCHITECTURAL DETAILS LS = LIFE SAFETY BRANCH F = AMPERE RATED FUSES PC = PLUMBING CONTRACTOR VFD = VARIABLE FREQUENCY DRIVE SD = SEE ONELINE DIAGRAM HOA = HAND OFF AUTO SWITCH CR = CRITICAL CARE BRANCH OCPD = OVERCURRENT PROTECTIVE DEVICE MAN = MANUAL CONTROLLER IU = IN UNIT BOL = BUILT-IN OVERLOAD EQ = EQUIPMENT SYSTEM EC = ELECTRICAL CONTRACTOR MAG = MAGNETIC CONTROLLER NU = NEAR UNIT WP = WEATHER PROOF EM = EMERGENCY SYSTEM FSEC = FOOD SERVICE EQUIP. CONTRACTOR CS = COMBINATION CONTROLLER OU = ON UNIT FD = FUSIBLE DISCONNECT ES = ESSENTIAL SYSTEM MC = MECHANICAL CONTRACTOR RVS = REDUCE VOLTAGE CONTROLLER SFP = SEE FLOOR PLANS LMRS = LOCKABLE MOTOR RATED SWITCH OPTIONS: 1 = SINGLE RECEPTACLE 4 = NON FUSIBLE DISCONNECT 7 = LOCKABLE 10 = VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION 13 = GFI RECEPTACLE 2 = DUPLEX RECEPTACLE 5 = FUSIBLE DISCONNECT 8 = CONCEALED 11 = SURFACE MOUNTED 14 = FED FROM UPSTREAM GFI BREAKER 3 = DIRECT CONNECTION 6 = WEATHERPROOF 9 = TOGGLE SWITCH 12 = FLUSH MOUNTED MECHANICAL EQUIPMENT SCHEDULE NOTES: 1. EC TO WIRE TO CONTROLLER K39. VERIFY FINAL LOCATIONS WITH VENDOR/MANUFACTURER. 241 N. Broadwav ...------ -- - -- Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 VVebsite: www.summiismitn.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-30 70 RING & 1 DUCHATEAU 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778,2360 / r-d@ringdu.cor RD Project Number: 218092.00 10 CONN F F � xOPHE� ly G': 4 No. 0033339 / (V =01 r ` L-I�/�� O O � U CD O `D W O ♦0Co A �W V / C � C U L_ O^ W i C-0 U � O � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: POWER SCHEDULES U Q Sheet Number: C- U ca E612 Y C 2. EC TO WIRE TO CONTROLLER K72. VERIFY FINAL LOCATIONS WITH VENDOR/MANUFACTURER. 3. EC TO WIRE TO CONTROLLER El 1. VERIFY FINAL LOCATIONS WITH VENDOR/MANUFACTURER. 4. E.C. SHALL PROVIDE 2-POINT CONNECTION AS INDICATED FOR CONDENSING UNIT. Am Wr a7 NEW PANEL SCHEDULE PANEL DESIGNATION CIRCUIT BREAKERS CKTS/ TUB # OF TUBS MOUNT PANEL LOCATION BRANCH PANEL TYPE PANEL BUSSING [AnAPCI MAIN VOLTAGE AIC* PANEL OPTIONS PANEL NOTES QTY AMP P TYPE OPTIONS z Ar,r, TYPE CB cI�G CB TVDG OPTIONS P. err NL_1-2 86 20 1 MC - 42 3 FM CORRIDOR C1012 N B 200 MLO - - - - 208/120 30, 4W 10 15 2 MC - 2 30 2 MC - 16 SPC 1 - -- NL_1-3 64 20 1 MC - 42 2 SM ELEC RM 1090 N B 200 MLO - - - - 208/120 30, 4W 10 15 2 MC - 0 SPC 1 - --- All I A IVL I--4 2 2V n IVIV - 42 3 JIVI ELEC RIVI 1U9V K. IV n D 2VV n�, IVILO - - - - ZU8/12U 30, 4W 86 20 1 MC - 15 15 2 MC - 1 30 2 MC - 8 SPC 1 -- ---- NL_1-5 96 20 1 MC - 42 3 SM ELEC RM 1022 N B 225 MLO - - - - 208/120 30, 4W 9 15 2 MC - 2 30 2 MC - e e nr e NL_1-6 50 20 1 MC - 42 2 SM ELEC RM 1022 N B 200 MLO - - - - 208/120 30, 4W 5 15 2 MC - 1 60 2 MC - 22 SPC 1 - --- NL_1-K 52 20 1 MC - 42 2 SM KITCHEN 1035 N B 400 MLO - - - - 208/120 30, 4W 1 20 3 MC - 2 60 3 MC - 23 SPC I 1 - ---- NL_2-1 83 20 1 MC - 42 3 FM CORRIDOR C2009 N B 200 MLO - - - - 208/120 30, 4W 8 15 2 MC - 27 SPC 1 -- --- NL_2-2 90 20 1 MC - 42 3 SM CORRIDOR C2011 N B 200 MLO - - - - 208/120 30, 4W 10 15 2 MC - 2 30 2 MC - 12 SPC 1 -- NL_2-3 89 20 1 MC - 42 3 SM ELEC RM 2086 N B 200 MLO - - - - 208/120 30, 4W 10 15 2 MC - 2 20 2 MC - 13 SPC 1 -- --- NL_2-4 94 20 1 MC - 42 3 SM ELEC RM 2086 N B 200 MLO - - - - 208/120 30, 4W 14 15 2 MC - 2 30 2 MC - 0 SPC 1 -- ---- NL_2-5 91 20 1 MC - 42 3 SM ELEC RM 2004 N B 250 MLO - - - - 208/120 30, 4W 11 15 2 MC - 4 20 2 MC - 1 30 2 MC - 1 30 3 MC - 0 SPC 1 -- --- NL_2-6 68 20 1 MC - 42 2 SM CORRIDOR 2007 N B 200 MLO - - - - 208/120 30, 4W 8 15 2 MC - 0 SPC 1 -- ----- ABBREVIATIONS: CIRCUIT BREAKER ACCESSORIES: PANEL OPTIONS: ACC = CIRCUIT BREAKER ACCESSORIES AF = ARC FAULT CIRCUIT INTERRUPTER (RESIDENTIAL ONLY) 1 = 200% NEUTRAL FM = FLUSH MOUNTED AR = ARC FLASH REDUCTION 2 = ISOLATED GROUND BUS PM = PAD MOUNTED CL = CURRENT LIMITING 3 = DUAL MAIN LUGS SM = SURFACE MOUNTED FR = FULLY RATED (100%) 4 = THROUGH FEED LUGS MLO = MAIN LUGS ONLY GE = GROUND FAULT PROTECTION (EQUIPMENT) MCB = MAIN CIRCUIT BREAKER GP = r;Rn1INn FAI II T PRnTFCTInN IPFRSnNNFI 1 PANFI TYPF& OPT = CIRCUIT BREAKER OPTIONS GS = GROUND FAULT SENSINGIALARM P = POWER PANEL CONSTRUCTION SFP = SEE FLOOR PLAN HC = HEATING, COOLING, AC, REFRIGERATION(HCAR) B = BRANCH PANEL CONSTRUCTION SD = SEE ONELINE DIAGRAM HM = HIGH MAGNETIC (HID, MOTORS) L = LOAD CENTER CONSTRUCTION SPC = PREPARED SPACE MS = MOLDED CASE SWITCH CB = CONTROLLABLE BRANCH PANEL RAD='v"vTvR CIRCUIT PROTECTOR CIRCUIT BREAKER OPTIONS: L1 = LONG TIME/INSTANTANEOUS(LI) * REFER TO ONE -LINE DIAGRAM GENERAL ALS = ALARM SWITCH L2 = LONG TIME/SHORT TIME/INST.(LSI) NOTES FOR ADDITIONAL INFORMATION ON AIC AXS = AUXILIARY SWITCH L3 = LONG TIME/SHORT TIME/INSTJGROUND FAULT TRIP(LSIG) RATING. EOP = ELECTRICAL OPERATOR L4 = LONG TIMEISHORT TIME/INST./GROUND FAULT SENSING(LSIA) S T = SHUNT TRIP SC = SYSTEM COMMUNICATION UVT = UNDER VOLTAGE TRIP SD = SYSTEM DIAGNOSTICS CCB = CONTROLLABLE CIRCUIT BREAKER SM = SYSTEM MONITORING ZS = ZONE SELECTIVE INTERLOCKING CIRCUIT BREAKER TYPES: MC = MOLDED CASE SS = SOLID STATE NEW PANEL SCHEDULE PANEL DESIGNATION CIRCUIT BREAKERS CKTS/ TUB # OF TUBS MOUNT PANEL LOCATION BRANCH PANEL TYPE PANEL BUSSING IAnAPc� MAIN VOLTAGE AIC* PANEL OPTIONS PANEL NOTES QTY AMP P TYPE OPTIONS Q. Arr, NPE CB el�� CB TVDG OPTIONS Q. Arr GENSET 24 1 MCB AF AT 480/277 30, 4W 24 SPC 1 - --- MDP-H 3 100 3 MC - 24 1 SM ELEC RM 1042 N L 2500 MCB AF AT 480/277 30, 4W 1 125 3 MC - 2 60 3 MC - 6 SPC 1 - ---- MDP-L 1 100 3 MC - 24 1 SM ELEC RM 1042 N L 2000 MCB AF AT 208/120 3f0, 4VV i I 125 3 mu - 1 80 3 MC - 15 SPC 1 - -- EMLD 24 1 SM EM P 175 MCB AF AT 208/120 30, 4W 24 SPC 1 - ---- OSLD 24 1 SM EM ELEC RM 1041A OP P 400 MCB 400AF 300AT SS 208/120 30,4W 24 SPC 1 - ---- ER. _I -I 28 4V 1 mu- 42 I JIVI R.E_C RM i090 CIVI P 1VV IVILV - - •• - ZU8/-12U 30, 4W 14 SPC 1 - --- EM_1-2 39 20 1 MC - 42 1 SM EM ELEC RM 1041A EM B 100 MLO - - - 208/120 30, 4W 3 SPC 1 - ----- EM_2-1 24 20 1 MC - 42 1 SM ELEC RM 2086 EM B 100 MLO - - - 208/120 30, 4W 18 SPC 1 - ----- EM-2-2 23 20 1 MC - 42 1 SM ELEC RM 2004 EM B 100 MLO - - - 208/120 30, 4W 19 SPC 1 - ---- OSH_1-1 4 60 3 MC - 42 1 1 1 SM EM ELEC RM 1041A OP B 250 MLO - - •• - 480/277 30, 4W � 30 SPC 1 - ---- OS-1-1 32 20 1 MC - 42 1 SM ELEC RM 1090 OP B 100 MLO - - -• - 208/120 30, 4W i 2 15 2 MC - 3 20 2 MC - 0 SPC 1 - --- OS_1-2 59 20 1 MC - 42 2 SM EM ELEC RM 1041A OP B 150 MLO - - - 208/120 30, 4W 1 15 2 MC - 6 20 2 1 MC - - ----- 11 SPC OS_2-1 24 20 1 MC - 42 1 SM ELEC RM 2086 OP B 100 MLO - - - 208/120 30, 4W 5 15 2 MC - 8 SPC 1 - ----- OS_2-2 25 20 1 MC - 42 1 SM ELEC RM 2004 OP B 100 MLO - - - 208/120 30, 4W 17 SPC 1 -- NH-1-1 25 25 20 1 MC - 42 2 SM ELEC RM 1041 N B 400 MLO - - - 480/277 30, 4W 1 30 1 1 MC - 4 20 2 MC - 2 15 3 MC - 4 1 20 1 3 MC - 3 25 3 MC - 1 50 3 MC - 20 SPC 1 -- ----- NH_1-2 12 20 1 MC - 42 1 SM ELEC RM 1090 N B 100 MLO - - - 480/277 30, 4W 2 20 2 MC - 26 SPC 1 -- --- NH_2-1 4 20 1 MC - 42 1 SM ELEC RM 2004 N B 800 MLO - - - 480/277 30, 4W 1 20 2 MC - 12 60 3 MC - 0 SPC 1 - NH-2-2 11 11 20 1 MC - 42 1 SM ELEC RM 2086 N B 400 MLO - - - 4801277 30, 4W 8 60 3 MC - 7 SPC 1 -- ---- NL_L-1 97 20 1 MC - 42 3 FM CORRIDOR 0003 B 200 MLO - - - 208/120 30, 4W 12 15 2 MC - 5 SPC 1 - ----- NL_L-2 22 20 1 MC - 42 1 SM ELEC 0023 N B 200 MLO - - - 208/120 30, 4W 3 15 2 MC - 2 20 2 MC - 2 30 2 MC - 2 15 3 MC - 0 SPC 1 -- -- NL_1-1 2 20 MC - 42 2 SM ELEC RM 1041 N B 200 MLO - - - 2081120 30, 4W 65 20 1 MC - 7 15 2 MC - 1 20 3 MC - 2 SPC 1 - '.SUMMIT SMITH DEVELOPMENT 241 N. Broadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-29'I 0 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 RING & 9-011 DUCHATEAU 17dM 1AIce4 r'� 4A Drive _ Rrnn4fiel J IAII F4f1AC i �wv vvwt vaNnvl vnvc - Lnvvnuclu, vvl �w->•v Phone: 414,778.1700 / Fax: 414.778.2360 I r-d@ringdu.coi RD Project Number: 218092.00 \���111111IIIf GO N NFcr pHEf2 'd `� No. 0033339 tV 00 r i O O � U n ,� L 0 W W -� W y-- O � Z U CU a C- (3) o 5. W U C-0 r O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: POWER SCHEDULES N ti Cn C14 C:) N U Q Sheet Number: U (B E61 3 �C C i7 Q PPVSUMMIT SMITH DEVELOPMENT CONTROL MODULE SCHEDULE DES INTERFACED WITH ACTIVATION DESCRIPTION RTU RTU-1 TEMPERATURE CONTROL PANEL INITIATES UNIT SHUT DOWN PROCEDURES UPON ALARM SIGNAL FROM UNIT AND SHAFT DUCT SMOKE DETECTORS. DH DOOR HOLD OPEN INITIATES RELESAE OF DOOR HOLD OPEN TCP TEMPERATURE CONTROL PANEL INITIATES UNIT SHUT DOWN PROCEDURES UPON ALARM SIGNAL FROM UNIT OUTDOOR AIR DAMPER DUCT SMOKE DETECTORS. ELEVATOR 1 SEE DETAIL 1/E520, CONTROL MODULE "FA2", FOR DESCRIPTION. EV EV ELEVATOR 2 SEE DETAIL 1/E520, CONTROL MODULE "FAT", FOR DESCRIPTION. FD FIRE DOOR INITIATES THE PROCEDURE UPON ALARM SIGNAL TO DROP THE FIRE DOOR OAD OUTDOOR AIR DAMPER CLOSES ASSOCIATED OUTDOOR AIR DAMPER UPON ALARM SIGNAL FROM ADJACENT DUCT SMOKE DETECTOR. SD SMOKE DAMPER CLOSES ASSOCIATED SMOKE DAMPER UPON ALARM SIGNAL FROM ADJACENT DUCT SMOKE DETECTOR. SPL SECURITY CONTROL PANEL / POWER RELEASES SECURED DOORS UPON ALARM SIGNAL FROM THE FIRE ALARM SYSTEM. SUPPLY CONTROL MODULE SCHEDULE NOTES: R W z m O 0 rnl 0 N Lu F—I U U r rn N ti M GV O N N MONITOR MODULE SCHEDULE DES. DEVICE MONITORED FIRE ALARM SYSTEM RESPONSE EV ELEVATOR SHUNT TRIP REFER TO DETAIL 1/E520, MONITOR MODULE "FA1" FOR DEVICE DESRIPTION FS FLOW SWITH INITIATES AN ALARM SIGNAL ON THE FIRE ALARM SYSTEM. HSP HOOD SUPPRESSION PANEL - SUPERVISORY INITIATES A SUPERVISORY SIGNAL ON THE FIRE ALARM SYSTEM. FP FIRE PROTECTION RISE PIPING, FIRE PROTECTION SYSETM DRY PIPING VALVE ASSEMBLY. TS TAMPER SWITCH INITIATES A SUPERVISORY SIGNAL ON THE FIRE ALARM SYSTEM. MONITOR MODULE SCHEDULE NOTES: 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 vveosite: www.summitsmitn.com Cm D -J, CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 -14 DIN HATEA UC U 17400 West Capitol Drive - Brookfield, WI 53045 Phone: 414.778.1700 / Fax: 414.778.2360 / r-d@ringdu.col RD Project Number: 218092.00 CON NF '(OPHE No. 00:1 ' tU r °a O O � U o U) W y— O O � to ca C U 2) O CD W U � � r O � � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TECHNOLOGY SCHEDULES C— U <Sheet Number: U CU E620 C i7 GENERAL NOTES A. EXACT LOCATION OF DEVICES SHALL BE COORDINATED WITH OTHER DISCIPLINES SHARING CEILING OR WALL SPACE. B. INSTALLATION OF RACEWAY SHALL COMPLY WITH TIA AND NEC RADIUS BEND LIMITATIONS. C. PROVIDE RACEWAY TO COMPLY WITH CODE AND AS SHOWN. D. COORDINATE WITH DIVISION 26 CONTRACTOR, FURNISHING AND INSTALLING ALL SUPPORTING PATHWAY FOR THE INSTALLATION OF THE SYSTEMS INCLUDING, BUT NOT LIMITED TO CONDUITS, BACK BOXES, WIREWAY AND RELATED ANCILLARY MATERIALS. E. INSTALL ALL DEVICES, CABLING AND APPURTENANCES IN A NEAT AND WORKMAN LIKE MANNER. F. COORDINATE INSTALLATION WITH PROJECT ARCHITECT, ENGINEERS AND GENERAL CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. G. COORDINATE FINAL PLACEMENTS OF DEVICES WITH GENERAL CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. H. REFERENCE ARCHITECTURAL PLANS AND ELEVATIONS TO LOCATE EXACT PLACEMENT AND FINISH SURFACE CONDITIONS. I. INSTALL CABLING IN APPROVED SUPPORT SYSTEMS AND RACEWAY AS REQUIRED BY CODE. J. CABLE SHALL BE INSTALLED CONCEALED UNLESS APPROVED BY AHJ, ARCHITECT, ENGINEER AND OWNER REPRESENTATIVE. K. COMPLY WITH THE NFPA, NEC, TIA, FCC, UL, IEE STANDARDS AND LOCAL AHJ FOR THE INSTALLATION OF CABLE AND EQUIPMENT. L. FURNISHED CABLE AND EQUIPMENT SHALL BE PROVIDED WITH ALL ACCESSORIES AND ANCILLARY HARDWARE REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM, M. COORDINATE PLACEMENT OF OUTLETS WITH MOUNTING HEIGHT AND PLACEMENT OF ADJACENT DEVICES. N. RACEWAY AND CABLE ROUTING SHOWN WITHIN FLOOR PLANS IS SHOWN FOR INTENT PURPOSES ONLY. COORDINATE THE PATHWAY AND MEANS AND METHODS WITH THE GENERAL CONTRACTOR AND DIVISION 26 CONTRACTOR. 0. DIVISION 26 TO PROVIDE PULL BOXES AS REQUIRED PER THE NEC AND TIA STANDARDS FOR TELECOMMUNICATIONS SYSTEMS. P. ALL RACEWAY AND SLEEVE PENETRATIONS SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF THE FACILITY. DIVISION 26 SHALL PROVIDE APPROVED FIRE STOPPING TO MAINTAIN CODE COMPLIANCE. Q. REFERENCE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF EXPANSION JOINTS, RATED PARTITIONS AND SMOKE BARRIERS, R. REFER TO STRUCTURAL DRAWINGS FOR RACEWAY ROUTING REQUIREMENTS IN SLAB. S. COORDINATE EXACT LOCATIONS OF WIRELESS EQUIPMENT WITH EQUIPMENT PROVIDER PRIOR TO INSTALLATION OF CABLING. T. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE UNLESS OTHERWISE NOTED. U. INSPECT FIELD CONDITIONS PRIOR TO THE START OF INSTALLATION. V. COORDINATE WORK WITH OTHER TRADES. W. WORK SHALL COMPLY WITH INDUSTRY STANDARDS AND MEET THE REQUIREMENTS OF LOCAL AUTHORITIES HAVING JURISDICTION. X. COORDINATE STORAGE OF MATERIALS ON SITE WITH GENERAL CONTRACTOR. Y. COORDINATE REMOVAL AND CLEANUP OF DEBRIS CAUSED BY THE INSTALLATION OF SYSTEMS WITH GENERAL CONTRACTOR. Z. COORDINATE THE PERFORMANCE OF ALL CUTTING, CORING AND PATCHING OF BUILDING MATERIALS AS REQUIRED FOR INSTALLATION. ALL PATCHING AND REPAIR SHALL BE DONE IN A SKILLFUL MANNER AND APPROVED BY GENERAL CONTRACTOR. AA. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS, LICENSES, AND CERTIFICATES OF INSPECTION NECESSARY FOR THE EXECUTION AND COMPLETION OF THE WORK. AB. ALL CONDUIT, RACEWAYS, CABLE TRAYS, PULL BOXES, OUTLET BOXES, FLOOR BOXES, SPLICE BOXES, AND SLEEVES 2" IN DIAMETER OR GREATER PROVIDED BY DIVISION 26. F., N 0 rn I W 0 Cb t W 0 CU L 0 M Q n, E W, n LCi co O CV O N OO TELECOMMUNICATION SYSTEM TELECOMMUNICATIONS DEVICES DESCRIPTION 7- MOUNTING IDUI TELECOMMUNICATIONS SINGLE PORT DATA OUTLET 18" - (1) CATEGORY CABLE TO SINGLE GANG JUNCTION BOX I DD2 TELECOMMUNICATIONS DUAL PORT DATA OUTLET - (2) CATEGORY CABLE TO SINGLE GANG JUNCTION BOX DD1-A-x TELECOMMUNICATIONS SINGLE PORT DATA OUTLET - (1) CATEGORY CABLE TO SINGLE GANG JUNCTION BOX - X - (#) MOUNTING HEIGHT - A - (TC) TIMECLOCK - A - (K) KIOSK - A - (W) WALL PHONE - A - (MS) MASTER STATION - A - (VEND) VENDING MACHINE - A - (RTV) RECESSED OUTLET ** - A - (DIG) DIGITAL SIGNAGE - A - (TV) DATA/TV SHARED *** OUTLETS NOTED WITH R# SHALL BE RECESSED OUTLETS, PROVIDED BY EC. COORDINATE INSTALLATION REQUIREMENTS WITH EC PRIOR TO INSTALLATION. V1/D1 ® TELECOMMUNICATIONS ®V1/D2 TELECOMMUNICATIONS ®V1/D1 FLR TELECOMMUNICATIONS WV1/D2 FLR TELECOMMUNICATIONS DD 1-(R)TV-# TELECOMMUNICATIONS DA1-B MDP 0 MP TELECOMMUNICATIONS SINGLE PORT VOICE / SINGLE PORT DATA OUTLET - (2) CATEGORY CABLES TO SINGLE GANG JUNCTION BOX SINGLE PORT VOICE & DUAL PORT DATA OUTLET - (3) CATEGORY CABLES TO SINGLE GANG JUNCTION BOX SINGLE PORT VOICE & SINGLE PORT DATA FLOOR OUTLET - (2) CATEGORY CABLES TO FLOOR BOX OUTLET SINGLE PORT VOICE & DUAL PORT DATA FLOOR OUTLET - (3) CATEGORY CABLES TO FLOOR BOX OUTLET SHARED DATA & CABLE TELEVISION OUTLET - (1) CATEGORY CABLE & (1) RG6 COAX CABLE TO TERMINATED INTO A SINGLE GANG JUNCTION B042- (RTV) RECESSED OUTLET *** -(#)- INDUCATED MOUNTING HEIGHT SINGLE PORT ANALOG OUTLET - (1) CATEGORY CABLE TO SINGLE GANG JUNCTION BOX - B - (FACP) FIRE ALARM CONTROL PANEL - B - (ELEV) ELEVATOR CONTROLLER - B - (PYXIS) PYXIS MACHINE - B - (EM) EMERGENCY "RED PHONE" - B - (D1) SHARED ANALOG / DATA OUTLET - B - (C) COPIER - B - (FX) FAX MACHINE TELECOMMUNICATIONS MEDIA DISTRIBUTION PANEL TELECOMMUNICATIONS MEDIA PLATE 18" AS NOTED 18" 18" FLR FLR 18"/ AS NOTED 18" * COORDINATION LOCATION OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND ELECTRICAL DEVICE * DE0S_1%UNTED ABOVE BACK SPASH SHALL BE ALIGNED WITH ADJACENT OUTLETS. IF NO ADDITIONAL OUTLETS ARE IN PLACE, MOUNT DEVICE 4" TO CENTER ABOVE BACKSPLASH. CABLE TELEVISION SYSTEM CABLE TELEVISION DEVICES DESCRIPTION MOUNTING DN CABLE TELEVISION TELEVISION OUTLET 18" / - (1) RG6 CABLE TO SINGLE GANG JUNCTION BOX AS NOTED TELEVISION & DATA SHARED OUTLET DTV-D CABLE TELEVISION - (1) RG6 CABLE & (1) CATEGORY CABLE AS NOTED TERMINATED INTO TO SINGLE GANG JUNCTION BOX TELEVISION & DATA SHARED OUTLET „ DTV-D1-# CABLE TELEVISION - (1) RG6 CABLE & (2) CATEGORY CABLE TO AS NOTED SINGLE GANG JUNCTION BOX * COORDINATION LOCATION OF DEVICES WITH ARCHITECTURAL ELEVATIONS AND ELECTRICAL DEVICE ROUGH -INS. TV OUTLETS SHALL BE ALIGNED WITH ADJACENT OUTLETS. SECURITY SYSTEM SYSTEM SECURITY SYSTEM DEVICES DESCRIPTION MOUNTING CR O SECURITY SYSTEM CARD READER 46" CRM OS SECURITY SYSTEM CARD READER - MULLION AS NOTED OPB SECURITY SYSTEM REQUEST TO EXIT PUSH BUTTON 46" MAG-R SECURITY SYSTEM 46" MAGNETIC LOCK EMERGENCY RELEASE BUTTON E=< SECURITY SYSTEM VIDEO SURVEILLANCE CAMERA AS NOTED K SO SECURITY SYSTEM WIRELESS LOCKSET - APARTMENT UNITS AS NOTED K1 SO SECURITY SYSTEM WIRELESS LOCKSET - FACILITY LOCATIONS AS NOTED KP SO SECURITY SYSTEM CARD ACCESS W/ KEYPAD 46" PX SO SECURITY SYSTEM CARD ACCESS PROXIMITY READER 46" DOOR HARDWARE SYSTEM - FOR REFERENCE ONLY DOOR HARDWARE DEVICES DESCRIPTION MOUNTING OD PN DOOR HARDWARE PANIC DEVICE EXIT HARDWARE -- OD PT DOOR HARDWARE POWER TRANSFER DEVICE -- OXDE DOOR HARDWARE DELAYED EGRESS EXIT DEVICE HARDWARE -- OD EL DOOR HARDWARE ELECTRIFIED LOCK -- OD DC DOOR HARDWARE RECESSED DOOR POSITION SWITCH -- OREX DOOR HARDWARE REQUEST TO EXIT MOTION SENSOR -- ONDE DOOR HARDWARE NON DELAYED EGRESS MAGNETIC LOCK -- OD DE DOOR HARDWARE DELAYED EGRESS MAGNETIC LOCK -- WIRELESS SYSTEM WIRELESS SYSTEM DEVICES DESCRIPTION MOUNTING U CLG WIRELESS SYSTEM WIRELESS ACCESS POINT CLG OAP-X WIRELESS SYSTEM WIRELESS ACCESS POINT - WALL MOUNTED WALL WALL -X- (EX) - EXTERIOR ENCLOSURE INTERCOM SYSTEM INTERCOM SYSTEM DEVICES DESCRIPTION MOUNTING BI INTERCOM SYSTEM DOOR STATION 55" BISM (X) INTERCOM SYSTEM STATION W/ DOOR RELEASE DESK/WALL -X- (R) DOOR RELEASE STATION BIM (X) INTERCOM SYSTEM MASTER STATION DESK/WALL -X- (R) DOOR RELEASE STATION AUDIO/VISUAL SYSTEM AUDIO / VISUAL SYSTEM DEVICES DESCRIPTION 7- MOUNTING JX AUDIONISUAL SYSTEM DUAL GANG OUTLET JUNCTION BOX AS NOTED - (X) - ZONE OF CONTROL AUDIONISUAL SYSTEM RECESSED CEILING MOUNTED SPEAKER CLG - (X) - ZONE OF CONTROL AUDIONISUAL SYSTEM RECESSED WALL MOUNTED SPEAKER WALL - (X) - ZONE OF CONTROL AS NOTED SO AUDIONISUAL SYSTEM RECESSED TILE MOUNTED SPEAKER CLG - (X) - ZONE OF CONTROL VX** $ AUDIONISUAL SYSTEM CONTROL DEVICE - VOLUME/SOURCE SELECTION 46" - (X) - ZONE OF CONTROL VX VOL AUDIO/VISUAL SYSTEM CONTROL PANEL - TOUCH SCREEN - SOURCE AND WALL VOLUME CONTROL - (X) - ZONE OF CONTROL ** VOLUME CONTROL SHALL BE INSTALLED AT STANDARD BUILDING MOUNTING HEIGHT OF ALL SWITCHES. MISC SYMBOLS MISCELLANEOUS DEVICES DESCRIPTION MOUNTING MISCELLANEOUS DEVICE SYSTEM TAG DESIGNATION -- - (A) - SCHEDULE REFERENCE - (B) - DEVICE IDENTIFICATION 0 MISCELLANEOUS DEVICE JUNCTION BOX AS NOTED 0 MISCELLANEOUS DEVICE SINGLE GANG JUNCTION BOX AS NOTED 0 MISCELLANEOUS DEVICE DUAL GANG JUNCTION BOX AS NOTED MISCELLANEOUS DEVICE RELAY DEVICE AS NOTED NO MISCELLANEOUS DEVICE KEYED NOTES -- OMISCELLANEOUS DEVICE CABLE TERMINATION NOTE -- WIRELESS EMERGENCY CALL SYSTEM EMERGENCY CALL DEVICES DESCRIPTION MOUNTING O E EMERGENCY CALL SYSTEM EMERGENCT BEDSIDE STATION 46" EO T EMERGENCY CALL SYSTEM EMEREGENCY PUBLIC TOILET STATION 44" O CK EMERGENCY CALL SYSTEM CHECK -IN DEVICE 44" EC-SVR EMERGENCY CALL SYSTEM HEAD END SERVER EQUIPMENT RACK EC-SVR EMERGENCY CALL SYSTEM STAFF PC LOCATION - REPRESENTATION ONLY DESK O B EMERGENCY CALL SYSTEM WIRELESS SIGNAL RECEIVER DEVICE AS NOTED A - (L) EMERGENCY LOCATOR A - (R) EMERGENCY REPEATER A - (EX) EXTERIOR LOCATOR B - (WALL) WALL MOUNTED B - (CLG) CEILING MOUNTED O M EMERGENCY CALL SYSTEM WIRELESS MOTION SENSOR O Z EMERGENCY CALL SYSTEM ZONE LIGHT O DM EMERGENCY CALL SYSTEM DOME LIGHT O DB-X EMERGENCY CALL SYSTEM DOOR BELL - (EX) EXTERIOR DOOR BELL ENCLOSURE DC O UT EMERGENCY CALL SYSTEM WIRELESS DOOR CONTACT SENSOR W/ UNIVERSAL TRANSMITTER OEMP UEMERGENCY CALL SYSTEM TEMPERATURE SENSOR W/ UNIVERSAL TRANSMITTER O UT EMERGENCY CALL SYSTEM WIRELESS UNIVERSAY TRANSMITTER O SA EMERGENCY CALL SYSTEM STAFF ASSIST O D EMERGENCY CALL SYSTEM DUTY STATION O SH EMERGENCY CALL SYSTEM SHOWER STATION AREA OF RESCUE ASSISTANCE SYSTEM AREA OF RESCUE DEVICES DESCRIPTION MOUNTING ARPS AREA OF RESCUE POWER SUPPLY -- ARAP AREA OF RESCUE ANUNCIATOR PANEL AS NOTED AR AREA OF RESCUE CALL PANEL AS NOTED AR S AREA OF RESCUE SIGNAGE CLG ABBREVIATION ABV ABOVE IL INTERLOCK ACT ACOUSTIC CEILING TILE JB JUNCTION BOX A rr Arr /1\ /r r1A llnl Irn rl !1/11"1 AB00 I_ ruNlnonw rwvrR /� LT G 1 1-1 IT _ LIOn I nvv AL ALUMINUM LV LOW VOLTAGE ALT ALTERNATE MFG MANUFACTURER ALT SW ALTERNATE SWITCH MOD MODIFICATION ARCH ARCHITECT MTD MOUNTED AWG AMERICAN WIRE GUAGE NEC NATIONAL ELECTRICAL CODE BFC BELOW FINISHED CEILING NC NURSE CALL BFG BELOW FINISHED GRADE NIC NOT IN CONTRACT BLDG BUILDING NU NEAR UNIT BOM BILL OF MATERIALS OAL OVERALL LENGTH BKR BREAKER OAH OVERALL HEIGHT CB CIRCUIT BREAKER OU ON UNIT CCTV CLOSED CAPTION TELEVISION PB PUSH BUTTON CKT CIRCUIT PEND PENDANT CL CENTER LINE PNL PANEL CLG CEILING R RELAY CNTLPNL CONTROLPANEL RECEPT RECEPTACLE COMB COMBINATION RECESS RECESSED COND CONDUIT REF REFERENCE DN DOWN RM ROOM DWG DRAWING REQ REQUIRED EAC EMERGENCY ACCESS CONTROL SPEC SPECIFICATION EC ELECTRICAL CONTRACTOR STD STANDARD ELEV ELEVATOR SURF SURFACE EO ELECTRICAL OUTLET SW SWITCH EMER EMERGENCY TEL TELEPHONE EMT ELECTRIC METALLIC TUBING TELECOM TELECOMMUNICATION EP EXPLOSION PROOF TYP TYPICAL ETR EXISTING TO REMAIN UNIV UNIVERSAL EXP EXPOSED WP WEATHER PROOF FBO FURNISHED BY OTHERS XFMR TRANSFORMER FIXT FIXTURE FLR FLOOR GC GENERAL CONTRACTOR GFI GROUND FAULT INTERUPTED GND GROUND GYP GYPSUM BOARD HVAC HEATING VENTILATION AND COOLING TS - SHEET INDEX Sheet Number Sheet Title TS000 INDEX, ABBREVIATIONS, GENERAL NOTES, SYMBOLS LEGEND TS001 EQUIPMENT SYSTEMS LEGEND 8, SCOPE MATRIX TS010 CONDUIT PLAN TS100 ACCESS CONTROL, AOR & SURVEILLANCE SYSTEMS - LOWER LEVEL PLAN TS101 ACCESS CONTROL, AOR & SURVEILLANCE SYSTEMS - FIRST FLOOR PLAN TS102 ACCESS CONTROL, AOR & SURVEILLANCE SYSTEMS - SECOND FLOOR PLAN TS200 TELECOMMUNICATIONS SYSTEM - LOWER LEVEL PLAN TS201 TELECOMMUNICATIONS SYSTEM - FIRST FLOOR PLAN TS202 TELECOMMUNICATIONS SYSTEM - SECOND FLOOR PLAN TS300 WIRELESS & AUDIO-VISUAL SYSTEMS - LOWER LEVEL PLAN TS301 WIRELESS & AUDIO-VISUAL SYSTEMS - FIRST FLOOR PLAN TS302 WIRELESS & AUDIO-VISUAL SYSTEMS - SECOND FLOOR PLAN TS400 EMERGENCY CALL SYSTEM - LOWER LEVEL PLAN TS401 EMERGENCY CALL SYSTEM - FIRST FLOOR PLAN TS402 EMERGENCY CALL SYSTEM - SECOND FLOOR PLAN TS500 ACCESS CONTROL DETAILS TS501 ACCESS CONTROL DETAILS TS502 ACCESS CONTROL DETAILS TS503 ACCESS CONTROL DETAILS TS504 TELECOMMUNICATIONS DETAILS TS505 TELECOMMUNICATION DETAILS TS506 ENLARGED TELECOMMUNICATIONS ROOM DETAILS TS507 TELECOMMUNICATIONS RISER DIAGRAMS TS508 SURVEILLANCE SCHEDULES & DETAILS TS509 AREA OF RESCUE ASSISTANCE RISER DIAGRAM TS510 AUDIO-VISUAL SCHEDULE & DETAILS TS511 EMERGCY CALL DETAILS TS512 MEDIA DISTRIBUTION DETAILS U]Wj 1�><1I17�1 " 51WI 171? 7 '_L 1� V, E: 1, G T1 /1// 1�1 Ail 7 2d1 NI RYn0rhel-M\! -r i�. uivG.+vvuy Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com i"Cf; teCls C 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " U (� LU -� 0 Q c C_ N U L_ O CM > W CZ � Q, = O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: INDEX, ABBREVIATIONS, GENERAL NOTES, 'SYMBOLS LEGEND U N L Q Sheet Number: CU TSOOO a N c tZ f� Li LOW VOLTAGE SYSTEMS SCOPE MATRIX FURNISH AND INSTALL (PROVIDE) DESIGN by DIRECT SUPPLY DIRECT SUPPLY Door Security Contractor LOW VOLTAGE ELECTRICAL CONTRACTOR GENERAL ISP or CONTRACTOR VENDOR HRA GENERAL AC Power, Wiring, Outlets and Connections X Building Service Grounding and Bonding into Data Room Location X Raceway and Support Systems for Systems Cabling X X Conduit Sleeve Penetrations, slabs, decks, floors, walls (conduits 2" and larger) X X Firestopping and Seals for Low Voltage Installation, Conduits less than 1" X Firestopping and Seals for Low Voltage Installation, Conduits GREATER than 1" X Telecom Rack Equipment Grounding and Bonding X X SALES TRAILER Low Voltage cable and connection for phones and Copier Equipment X 120V Power for Equipment X Trailer 8- Port POE Switch (set-up comes with trailer) ISP Temo Internet w/ WiFi Modem ISP ACCESS CONTROL SYSTEM Door Controller and Power Supply X X Magnetic Locks X X Card Reader Equip X X Access Control Cabling System X X Set up and Training X 120V Power for Access Control System X INTERCOM SYSTEM Door Intercom Station X X Master Intercom Station, Controller and Power Supply X X 120V Power for Power Supply X Rough -in Backbox and Conduit, as required X VIDEO SURVEILLANCE SYSTEM (Security Cameras) Cameras, mountings X X Cable System X X Network Video Recorder with video managemente software X X Special System POE Switch X X 120V Power X Rough -in Backbox and Conduit, as required X Set Up, Training & Integrations X ACCESS CONTROLLED DOOR HARDWARE - BY DIV 8 Power Supply for Locks (Including Electric Strikes) X* X Flartrifieri FAt Devices- Strikes Transfer HinLyes X* X Power Supply for Exit Device X Fire Panel Interface to electrified lock power supply. X Door Position Switch X* X Auto Door Operators X Auto Door Operator Control Device X *This contractor shall provide wiring connection from Access Control System to electrified hardware for monitoring and control. Electrical Contractor shall provide connection to electrified hardware power supply, and connection between electrified hardware and Div 8 provided power supply. Access Control Sysetm shall be coordinated with the approved electrified hardware... DATA NETWORK SYSTEM Data and Network Vertical and Horizontal Cable & Distribution (Fiber and / Copper) X X Data Cable, Terminations, Final Labeling and Cert. Testing X X Termination of Voice / Data at Jacks & Wall Plates X X Termination at Patch Panels within rack enclosure X X POE Switches X X Non POE Switc-es n n Voice Cable, Terminations, Final Labeling and Cert. Testing X X Fiber Terminations X X Patch Cords X X Power for Rack Equipment, Surge Suppression X X UPS Equipment on the Rack X X MDF Racks X 120V Power at the Rack and Rack Equipment X lintarnat Cnrvira Prnvirlarl ICP Pniitar ISP x Plywood backboard mounted, painted X Adtran Fire Wall VPN Router X PCs, printers/fax equip., copiers X WIRELESS NETWORK SYSTEM Wireless Access Point Equipment X X Wireless Access Point Cabling System X X POE Switches X X Patch Panels X X Equipment Configuration X VoIP PHONE SYSTEM Phone Equipment Locations (cabling) X X Phone System POE Switch X X Phone Equipment X Phone System Installation X Phone System Equipment Configuration X POINT OF SALE SYSTEM (POS) Point of Sale Equipment Locations X POS Point of Sale System Installation POS Point of Sale System Configuration POS EMERGENCY CALL SYSTEM (WIRELESS) - (PC-PALCARE) Emergency Call System X X PC Emergency Call System Server X X PC Emergency Call Station Devices X X PC 120V Emergency Power Requirements for System Repeaters X Data Connectivity for Networking of System X X Fire Alarm Interface for System Monitoring (FAC - Fire Alarm Sub -Contractor) FAC CABLE TELEVISION SYSTEM (CAN - CABLE TV VENDOR / ISP) MDF Room Dmarcation -Termination X CAN Plywood Backboard X RG11 or Hardline Backbone Cabling, as required by Service Provider X X RG6 Horizontal Cable X X CATV Jacks and Wall Plates, As Required by Provider* X X Cable Television Cable Routing, Amplifiers, splitters and calculations, final terminations X CATV *Does not include TV's or TV mounting brackets. Final installation requirements shall be... TYPICAL AUDIO / VISUAL SYSTEM 120V Power for Audio/Visual Equipment X Audio / Visual Equipment Rough - back boxes and conduit as required X X Speakers and Volume Control for Zoned applications X X Audio / Visual System Cabling X X Audio / Visual Racking Installation and Set Up X TWO-WAY COMMUNICATION SYSTEM (AREA OF RESCUE / REFUGE) Systems Equipment X X Rough -in requirements (backbox, conduit) X X 120V Emergency Power Requirements for System X Coordinate the location of the AHJ approved Anunciator Panel prior to installation. BUZZ TIME TRIVIA TV (BUZZ) Systems Equipment X BUZZ 120V Power Requirements for System X Rough -in Requirements (Conduit and backboxes) X X Cabling Requirements X X NOTE: Resident Technologies are based on Owner and Operator Discussions and Terms of... SUPPLY HAWK (HAWK) Systems Equipment (Tablet) location X HAWK Rough in requirements (power outlet) X Installation of Equipment HAWK DAS (DISTRIBUTED ANTENNA SYSTEM) Rough in requirements (power) locations X X '.SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 1Cm D 93M�ym CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " W!:; C �C— O C) L C) L j LU U L CU O a = V_ Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: EQUIPMENT SYSTEMS LEGEND �& SCOPE MATRIX J J U N U Q Sheet Number: C_ U cu O Y b F., W 0 C2 LOW I LAUNDRY 0024 , li �1 HOUSE KEEPING _002." CLEAN LAUNDRY 0022 ' r F o r LOWER LEVEL - UNDERGROUND CONDUIT PLAN SCALE: 3/32" = 1'-0" KEYED NOTES: 1. UNDERGROUND CABLE BY LOCAL SERVICE PROVIDER TO HAND HOLE: SHOW ROUNTE AND HAND HOLE ON SHEET C101 AND SEND TO CIVIL ENGINEER 2. HAND HOLE 3. (3) 4" UNDERGROUND CONDUITS FROM HAND HOLE TO IT DEMARK 0018 BY DIVISION 26. 4. PROVIDE LONG SWEEP BEND IN UNDERGROUND CONDUITS. 5. STUB UP (3) 4" CONDUITS IN IT DEMARK TO A MINIMUM OF 4" AFF. #"SUMMIT ........ . . SMITH DEVELOPMENT 241 N. RrOad.^.gar Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D F1___J] CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY CD U ^^� L � r) W W o ^ W a c C Q) U � L O N W U U 0 a = o Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: CONDUIT PLAN C_ <Sheet Number: U .N Cz TS01 0 .�c C 0- Q ®®SUMMIT SMITH , TH VTEZ 0PMENT �n i C2 -000 C2 p - LAUNDRY 0024_ _ nr nrn v �-. v i. CROOD O SECURITY 11 C0004 HOUSE KEEPING 0023 CLEAN LAUNILJ 0022 _. I PASSAGE 00004 ,_, CAMERA inn CAMERA 101 S DBDC D g(�@� s i SECURITY 2A V0001.2 C STOH 0018_', LEV•: -1.3 SECURITY 10 0011CR C C( CGu L- J u J *SOILEDLl 0 El SOILED LAUNDRY ao2_ ELEC_ 0017_. UDCI � A III S3.02 D a If o ACCESS CONTROL, AOR & SURVEILLANCE SYSTEMS - LOWER LEVEL SCALE: 3/32" = V-0" f� 0 c a� 0-)I 0 F-- CL 2) W 4- 0 Tn U L 0 Q n co O ti O N O N O SECURITY GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. 241 N, Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D UUINIS I RUC I IVIN or-MvICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-30 70 aptura. DIF 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " i co (3) U LU ch CCS � U � L LLJ ` v C:) a� a) Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL, AOR & SURVEILLANCE ,,'-SYSTEMS - LOWER RLEVELPLAN 0 U Q Sheet Number: U co a c6 TS100 C d R O Y Y OI Ch H c a) Lu 0 a) U 0 .n _ Q a� ry U n 77 d- r- O N O N O SECURITY \ �7 I S1.12 CAMERA ❑ ❑ ❑ DCO � 102Li n C1 C2 C LAUNDRY 06 C1 05 1055 _ !} 1 _ 1056_ _ 1057__ � 0 u ---' --_ 1058- C2 - c1 c - - - - - - 1052-- R-77=: b p - 1C4 ---' C3 1 i - J . - - _ 1051--- l �- U L- ❑ �1 (- n IT ❑ n C STAIR- 1054 i Si-1ELI A n F-1 -- - \ 050 - CORR CORR C1008 ICR FTLCORR C 1012 STOR :. 1067 A 1 88_j ------ _ 1049- \ MAINT TILT TLT O O OCR CORR_ Q I I / 1045--' 1046_' 1047 ' I - DC DC ELEV•2 C1007 .z u DIR OF MAINT SECURITY E1.2-- S _ 116 - \ I CR O CARE PARTNER MEDS \ 1 C1008 - _ -loss:.? EDS - - U SECURITY (P)DC PASSAGE c1009 . CR 1065 � � -- -�� n —77 C2 S OFFICEd r-1647 Lpa==�j yI Qn [F STAIRN 064 _ u - 4 V EMERG POWER JAN v �� �� � 53• _, I I � / 4 � DC DC SECURITY I I I II STAFF \ I I I I 1041A SECURITY I I I y O i0a3_; 1039 10 11A OCR 1035.3 �1 i 1035.4 - - - -- DCO I IIII, � I f pC MAIN ELEC FF-- SECURITY - 6 C1010.2 ODC CAMERA SECURITY 103 4 1041.1 DC V I DISHWASH I I 1=11037:_' I J o �V ST ` 1036_- IVATE DINING SECURITY ILIEXHI8 KITCHEN 4 1033_ WAIT STATION 1030.2 T 1034 DC '—' �''Lflf fl I i EDI DI I.1030 ` EF-�] E�-�l STOR MAITRE D' SECU4RITY C� 1029_ nn f026_ 1030.1/�^�?/�^ II CAMERA 104 SECURITY DCO S4712 CR " SECURITY VC 2B BISTRO 1017 ODC -1017 ACCESS CONTROL, AOR & SURVEILLANCE SYSTEMS - FIRST FLOOR SCALE: 3/32" = V-0" J CORR C1006_- - C1 1070 , CAMERA 105 (:1 —j F0 %F. Ejj UU C1 106 _ C1 O B \ 0 � ,I�I�L. ❑��� u I. . � 0 MC-P MC-P 1076. j 1077. __ '7 I 1 CORR CR sEcuRITY 5 C1005 DCDE DE DC C1005 CR SO D D lid LOU MC•SP BAR 1075 1073A , i DC D D DEUCR DC D D DE SECURITY 1104.2( CORR _C 1013 L CRO LCOVE C1oi4-- ❑ El ACTIVITY 1098 ' ❑ GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. ES: KEYED NOTES: 1. MANUAL MAGNETIC LOCK RELEASE STATION WITH PROTECTIVE COVER SHALL BE PROVIDED TO ALLOW MANUAL RELEASE C!F MAGNETIC LOCKING THROUGHOUT THE COMMUNITY. RELEASE DEVICE SHALL BE EMERGENCY DOOR RELEASE MODEL SDC 492, OR EQUAL. \ 2. MANUAL MAGNETIC LOCK RELEASE STATION WITH PROTECTIVE COVER, LOCATED \ BEHIND CLOSED DOOR, SHALL BE PROVIDED TO ALLOW MANUAL RELEASE OF MAGNETIC \� LOCKING THROUGHOUT THE COMMUNITY. RELEASE DEVICE SHALL BE EMERGENCY DOOR RELEASE MODEL SDC 492, OR EQUAL. 3. (2) 1" CONDUITS, ONE FROM GATE HINGE SIDE AND ONE FROM GATE LATCH SIDE TO NEAREST ACCESSIBLE CEILING SPACE WITHING BUILDING. 4. COORDINATE LOCATION OF EQUIPMENT WITH FIRE ALARM PANEL. PROVIDE MANUFACTURER RECOMMENDED BACKBOX AND CONDUIT TO ACCESSIBLE CEILING. 4 I MC-P MC-P 1078-_ 1079_ \ MC S I ' 10-80 I SECURITY 10 r 2� MAG-R❑ ODC 1094 O CR rr .L �\l i CORR C 1015 r- I I -- SECURITY STAIR-1 k 7 D DE .: s51 ODC S5.12 D DC CRO SECURITY O S5.11 ' OCR -GATE IIII NDE GATED ODC O Ir � 1 1p SECURITY DEOODC SECURITY ❑U-J L��1 1074 O 7� c1 �+' CR CR I A \� MC-P o 1081 _� MC -P 1081 a ❑ ❑, SECURITY t— 1098 SECURITY S6.11 OCR IDEDC AR SECURIF I ;G•1- . 7 S6.12 I � � I i I I/ 1= I 7/ FOR DOOR SCEHEDULE i CAMERA 106 DCOONDE GATE CRO OCR DE D D DC — / SEiCC-U ITY ❑❑ '.SUMMIT SMITH DEVELOPMENT 241 N° Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIREC 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA c 2019 DIRECT SUPPLY � U W W Lam- o v ) nO W ch V C- � C)CD w U L� C 0 a = CD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL, AOR & SURVEILLANCE 'SYSTEMS - FIRST FLOOR PLAN U <Sheet Number: C- U ca TS1 01 =3 Y C 0 GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. PPTSUMMIT SMITH 1 >/EV LOPMENT 241 N. 6rnndwav ❑ 11❑ i I I I I I I M � ACCESS CONTROL, AOR & SURVEILLANCE SYSTEMS - SECOND FLOOR SCALE: 3/32" = 1'-0" B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. MANUAL MAGNETIC LUCK RELEASE S T A T ION VVI T H PROTECTIVE COVER, LOCATED BEHIND CLOSED DOOR, SHALL BE PROVIDED TO ALLOW MANUAL RELEASE OF MAGNETIC LOCKING THROUGHOUT THE COMMUNITY. RELEASE DEVICE SHALL BE EMERGENCY DOOR RELEASE MODEL SDC 492, OR EQUAL. Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-30 70 aptura. DIRECT 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY " Qn) U L W W C— y_ ® O U) c^W C C (3) U LLJ U S� C 0 aIr- Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL, AOR & SURVEILLANCE 'SYSTEMS - SECOND FLOOR PLAN U Q Sheet Number: C— U a Ca G.TS102 N 0 r 9UMMIT SMITH DEVELOPMENT 241 N. Broadwav D1-SCE n 1 - 2 TuDaTv VEST D 1-S� 00001 ® �� it l I 1 10 D1 AP n o V1/D1 STDR [0013 771 H V1/D1/A1 LE--1 1 2 4 1 3 4 1 TV D aTV o I TV D I�I i <1 Tv 0 000 • �j TS506 D 1 AP 3 r T /�'- ---j 1 I r -C'l = II CZ n 0010 IV><TV TELECOMMUNICATIONS SYSTEM - LOWER LEVEL SCALE: 3/32" = 1'-0" F-1 0 c a� rn I 0 Cb 2) W 0 U 0 2 Q ry n N O N O N O Tv D n o T= c1 0 0008.1 If ' i TV TV r �0 a TV A V000s_: ZA TV GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. 1" CONDUIT TO ACCESSIBLE CEILING SPACF_ AND WEATER PROOF BACK BOX PROVIDED BY DIVISION 26, FOR INSTALLATION OF EXTERIOR WALL MOUNT SECURITY CAMERA AND CABLING. 2. BACK BOX AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE BY DIVISION 26, FOR INTERIOR CEILING MOUNTED SECURITY CAMERA. 3. SINGLE PORT DATA FOR WIRELESS ACCESS POINT. IF LOCATED AT IN -ACCESSIBLE CEILING SPACE, BACK BOX AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE TO BE PROVIDED BY DIVISION 26. CABLE TERMINATION NOTES: 1. TERMINATE STRUCTURED TELECOMMUNICATIONS CABLING IN THIS AREA ON PATCH PANELS INSTALLED ON RACKS IN TELECOMMUNICATIONS ROOM DEMARC 0019, UNLESS NOTED OTHERWISE. 2. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPUTTERS IN DEMARC 0019. 3. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPUTTERS IN IT 0015. 4. 1 tKIVIINA I t UA I A UAbLINU t-UK VVIKtLtbb AUUtbb F'UIN I J IN I Nib AKtA UN t'A I uti PANEL INSTALLED IN HUBBELL RE4 WALL MOUNT CABINET IN DEMARC 0019. ------------- Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 vveasite: www.summitsmlth-corn cm 13 M\-/ �TLFU CVIVS 1 RUC 1 IUPI SErnCV Ikalzo 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 a aura® DIRECT 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " ca �. S � U W � (j) c a CCS � U CL) 2) w v 0 o Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TELECOMMUNICATION SYSTEM - LOWER LEVEL PLAN CL -1 J U N U C- Sheet Number: U a cuTS200 Y C d R D1 SCE a 1 CORR �! C1008 DIR OF MAINT A 77 V1/D1 TL' _ _104 v I,v 1 - MAINT I 1045 _. a D1 - -- I �I I D1 a TC-46 D D 1-TV-60 VESTIBULE C 1010 ❑ ❑ a D1-HVAC D1-FPI Al r7) FACP n SCE TS506 I j- V1/D1 ELEV•2 Et•2 ! AP V1/D1/A1 r PARTNER �� `�� CARE 1065.. • - i PRIVATE DIN[ D2-POS D2-POS-46 WAIT STATION � � �`ti � �_. — - — • — - — • — - - - — - — • — - — • — - — • — - — - — - — • — - — - — - \ f> K I DI INEE�3 /rA TLT 68 _ I 4- /(k -,<. UM Tv w I TV AP -� � '7 1Li 4 5 1 3 4 1076 - C2 1 ,/ 1071 I 2 I filr� \ i j CORR Q C 1005 ® / 1 ' -AP I I F-i D2-POS ' n C] a r D1-TV-60 I - - - -' LOU M104P \0 1073 j ❑ 111 \❑ I I J D1 / TV D TV AP a EF M E-2 q---1 D1-TV-DIGI-SIGN LE ❑ > _❑ ❑ �� D2-POS D STOR SUNROCM ) ❑ 0 INING MAITRF D' ; _1072 .. , ® ° < U V1/D1 ' AP CORR F-C1003 _ . p V1-W-46 WOMEN MEN ❑ [ ❑� D1 iazo J .:1021 SCEAl 0 4 3 STOR \ 0i0VE _ _ 1027 ciao4_ TS506 ❑ HK 1019_: A ❑„ ❑ ❑ I ' ELEV-2 STO ' =�j -E2-2.. 1.024 , � ll I v OM ❑ �� I 102 L-J � ww- ELEC I �❑ 1022,-' � BISTRO ® 1 I I I I J � AP TV ,-� C 0 (❑ ' �__ ---- ❑� D2-POS' I TV D a TV -- ___ --- �/ D1-TV-60 G O H, V1/D1 �I - 17 \ TV D a lV LI C3 1014 .. CONCIERGE f _ _ - PANTRY 101E (� I M1 •SF ❑❑, DIR OF RES CARE - - i D2 _- GRAND LOBB _ 1002 COPY TV ; ^1015 D2 f / Lz=zjj V1/D1/A1 17 STOR 1013 v ❑ - 1003 ' CORR D1=c�6o2.-- ,\ D1 1 � A AP -- - - -- A AP AP i loz_ 1 /J MC LOBBY TV ❑ ❑ I >�iioa J� o ❑ V1/D1 - �/ I- I 1 n R r� p I V� - -L / =T D BUSINESS OFFICE I ❑ F - LAUNDRY - - - _ - _ 1009_ -1011 - � ` CQ �4p� El - 3 - U ' -- MC-P --- D1-TV-60 O El DIFO ' CONFERENCE TV TV TV ❑ TV V1/D1_ ❑ 4 - IR MARKE N ' .I.v 6 D 1 i o04 ❑ EXEC - SC•, Dl-TV-60 Y V1/D2 i ' V1/D1 � , 0 ❑ V1/D1 6SPI LITY ❑ ' � ❑ 10.06_ � t�� I D1a 1 2 4 1 3 4 SCE TELECOMMUNICATIONS SYSTEM - FIRST FLOOR SCALE: 3/32" = V-0" SCE GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. RECESS MOUNTED MENU BOARD TV. 2. 1" CONDUIT TO ACCESSIBLE CEILING SPACE AND WEATER PROOF BACK BOX FOR INSTALLATION OF EXTERIOR WALL MOUNT SECURITY CAMERA AND CABLING PROVIDED BY DIVISION 26. 3. BACK BOX AND 1" CONDUIT TO ACCESSIB LIE CEILING SPACE FOR INTEROR CEILING MOUNTED SECURITY CAMERA PROVIDED BY DIVISION 26. 4. SINGLE PORT DATA FOR WIRELESS ACCESS POINT. IF LOCATED AT IN -ACCESSIBLE CEILING SPACE, BACK BOX AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE TO BE PROVIDED BY DIVISION 26. PROVIDE 10" SERVICE LOOP AT EACH LOCATION. 5. 1" CONDUIT BENEATH FLOOR SLAB FROM CHEF'S TABLE TO NEAREST FULL HEIGHT WALL FOR DATA CABLING PROVIDED BY DIVISION 26. REFERENCE DETAIL 5/TS505 FOR ADDITIONAL INFORMATION ON CONDUIT ROUTING AND INSTALLATTON. 6. 1" CONDUIT BENEATH FLOOR SLAB FROM FLOOR BOX TO NEAREST FULL HEIGHT WALL FOR DA TA CABLING PROVIDED BY DIVISION 26. 7. COORDINATE EXACT LOCATION OF EQUIPMENT WITH FIRE ALARM CONTRACTOR. CABLE TERMINATION NOTES: 1. TERMINATE STRUCTURED TELECOMMUNICATIONS CABLING IN THIS AREA ON PATCH PANELS INSTALLED ON RACKS IN TELECOMMUNICATIONS ROOM IT 1025, 2. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPUTTERS IN IT 1025. 3. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPUTTERS IN IT 1091. 4. TERMINATE DATA CABLING FOR WIRELESS ACCESS POINTS IN THIS AREA ON PATCH PANEL INSTALLED IN HUBBELL RE4 WALL MOUNT CABINET IN IT 1025. 5. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPUTTERS IN IT 1054. U---U I_ J FOR DAR SCHEDULE �I.SUMMIT SMITH DEVELOPMENT 241 N, Rrnar[wav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com co A I M3MU7LF711 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura.) DIREC 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY Y SOO ca d- co i L O W W �� L1- nO /WD CU V i 0 > W +-� U N 0 a = o r Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TELECOMMUNICATION: SYSTEM - FIRST FLOOR PLAN J J U C- <Sheet Number: U co ca 0 '.SUMMIT SMITH pa 0 c Y �I 0 cis H W O m U 0 ry U M d" ti O N T- V- O N OO O CORR D1 ® a C2009 AP Tv v IV IV V <TV 6 CORR 2 1 TELECOMMUNICATIONS SYSTEM - SECOND FLOOR SCALE: 3/32" = l'-0" NDaN TV iir - ��'TI �I TV �1 TV TV I v TV TV C2 I ct TV TV 2042 ..-2045 .,i C1 - - - - 2046_ -- cn 2047 _ 2048TV .. - - a oilTV1� / —I r - � all 7 P �, TS506 � CU47 -- - - �� CORR G V1/D1 STOR TILT 2050 �® 2056_ , ''- AP 9 \ ` - i� � i _i I \J ELEV.t -D1 1� \ I'.!J- i y= I �11 v I J AP V1/D1/A1 � —j L—!U TV r El CARE PARTNER MEDS Q 47j 1L\\ 2054__ 2055_ ( TV I I I ---IIIIII 1! u 0 a C2 — ��I C, 2034 V.i ® 263_ - 2052177F 2051 - 4 I FTV � I ' _i - HKP 1G `�' LV Ala TV �� IV ,�_. �. TV > �' I V 1 11 TV T1 r � / 2068 o 2 -- C, 1 �\ TV P 3,-- ILI GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. COORDINATE EXACT LOCATION WITH ELEVATOR EQUIPMENT PANEL. 2. SINGLE PORT DATA FOR WIRELESS ACCESS POINT. IF LOCATED AT IN -ACCESSIBLE CEILING SPACE, BACK BOX AND 1" CONDUIT TO ACCESSIBLE CEILING SPACE TO BE PROVIDED BY DIVISION 26. PROVIDE 10" SERVICE LOOP AT EACH LOCATION. CABLE TERMINATION NOTES: 1. TERMINATE STRUCTURED TELECOMMUNICATIONS CABLING IN THIS AREA ON PATCH PANELS INSTALLED ON RACKS IN TELECOMMUNICATIONS ROOM IT 2012. 2. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPLITTERS IN 1 I 2V 14. 3. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPLITTERS IN IT IT 2079. 4. TERMINATE DATA CABLING FOR WIRELESS ACCESS POINTS IN THIS AREA ON PATCH PANEL INSTALLED IN HUBBELL RE4 WALL MOUNT CABINET IN IT 2012. 5. TERMINATE COAXIAL CABLES IN THIS AREA AT WALL MOUNTED SPLITTERS IN IT 2043. TV LM - - I 064E W M066P, ND aTV - - IO 1O 4 5 11 3 ® TVD L - �<TV TVD I - - qN \ MC SIP MU p_ 2063 1 -1� INSTV - _ ——� 2 C2 I Q ---- 2060 ' 4 r-� Lj gr'�j -_-_-_-_-_- C; L__J 110 CORR C2006 \.� ( AP I - - - AP AP 1 � I F;�-__, MC DINING /� 2029 I _ DIN _. `t-s V1/D 1 �i � V1/D1 � MAssacI �d-El - 2028 Oi V1/D1 "ONSULT_D1-TV-60 I MC•SP -, _ _ 2062 _ III 1 L = I / i C��T - - - - - . I COUNTRY KITCHENI I L J17 L V1-W-46 TVD <TV ; 2oa? - - - I I �IU ° 1 - TV �,c • P MC•P1-W=4 2668 TV 0 20s7 17 _ P2083V WELLNESS 2025 - -- - AP V1-W-46 b ATV , a L�� I MC•P SALON\, TV MC•P 2688 208 _ , 206-9 ' TILT HKP 2081 - - - - — — Tv TV MC•P ELEV•1 /EO � MC•P TV 62: AP V I 2089_ L E3-1 � 2070 C2 0 ELEV Q Al - 0 2024 I - —-- I TV -- Q O i I i 0 MC P C - P L - - I Tv �i --- �/ 2071. � LAUNDRY --7' � -- IV ' _zo7a_ C2 I -- -- C AP -- -- 1 2023 _. 2086 20's TV CORR 1 _ _ _ C2003_ "8 , (1 MC • P 2072 MC P„ TV CL LINEN i TV -- 2091, \ _2075 _ L OILED b _ \ zo7f TS506 17 I I I STOR J ILI L / 2074A ' 2076 _' \ TV Q TV jo ( g cd, b 1 0 M2094P_ TV MC _P ^ �� MC TV 2092__ `\�/, 1 _2073_ CARE_ PARTNER i 2074 AP V1/D1 V1/D1/A1 V r — _Ly -- �; IIIUI (off W r/ TS510 2 ACTIVITY iJ L I I I 2 D1-N-60 D TV-60 TV-60 TV-60 T01 I j I' AP AP MC �� li LOBBY / O � 2100 MC-P 40 4c I 2099 - - - - 0 Q I -I� TV �I - TV - - MC - SP - - , TV P, 2002 _; TV'I TV zoos i� • TV > I MC•P MC•P MC•P a N \� r , 2098__, ;_2097._ 2096 _ a Iul iuI g I ll TV D. TV -- 14 4 0 00 E1110 0 L DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com IC13 A I ffmoTH CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura® DIRECT SUPPLY 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA c. 2019 DIRECTSUPPLY " C� S � U a� W 4� 0 C) Cn 0 A ca U CI) L � W U Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TELECOMMUNICATION; SYSTEM - SECOND FLOOR PLAN <Sheet Number: U Cc6 TS202 Y 0 '.SUMMIT SMITH DEVELOPMENT 941 N Rrnariwav DS DS DS DS I - — - DS vrsr. C1 I1, - C1 , 0003 j L oOU C1 000a , _ c1 — - - ----- o0os_: • ELEV•3 -- . - I II - . . — -11 . _. . �f_ - - CARE PART i - �- [.0011 l HOUSE KEEPING 0023 _ IT MEDS J- 7 . Ln PASSAGE 00004 CLEAN LAUNDRY 0022 SOILED � 0026 SOILED_ LAUNDRY 0021 1 F- C1 C1 _0008-: C2 0069 l ;• --- I DS DS WIRELESS & AUDIO-VISUAL SYSTEM - LOWER LEVEL SCALE: 3/32" = V-0" W DS A 0006_' A DS GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com C 13 CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 4 cJ tecls. 'Ic 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax:414-359-3070 a tura® 1REC 6767 North Industrial Road Milwaukee WI53223 844.4APTURA 2019 DIRECT SUPPLY " seo S � U O L � W y_ 0 O c C— O U L_ 2) W O a = Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: WIRELESS & AUDIO-VISUAL SYSTEMS - LOWER N U N 75 In co d' ti O N O N O O U` U Q Sheet Number: C_ U co (B 0 Y C d DS DS P"SUMMIT SMITH N Y C �C1 O rA 0 Ch IL Cv W 0 a� U `0 CU _ Q ry CL E U n I.C) ti O CV O N OO O DS DS I DS f DS DS D LAUNDRY DS �7 DS DS MEDS _i ✓ _ I ucW = �\ - 1066 l r� • I � - 1 _.I C - f - r o PASSAGE 63 10 i � DS DS DS DS ter. X w CLG a I @ JAN - DS DS VU ❑ ❑ ❑ Ap DS DS DS CLG U LJ I COPY --- - 1015 AP — i;LG G _ - - - - BUSINESS i © ti Vl A / \ low . r v r cl_ � - 1 9^ - � 00 TO S R 0 i 0 t y- _ tODS LAUNDRY WIRELESS & AUDIO-VISUAL SYSTEM - FIRST FLOOR SCALE: 3/32" = V-0" DS DS DS DS los 0 Cn 0 0 U) 0 GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. C.TERMINATE DISTRIBUTED AUDIO SYSTEM CABLING IN THIS AREA AT EQUIPMENT IN TELECOMMUNICATIONS ROOM IT 1025. GATE FOR DOOR SCHEDULE DEVELOPMENT 241 N. Broadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D n n !� /1 A 1 [�TP11 ,I-//11iLJ V LJ �n`�rLJ Ll UUNO 1 r\uu 1 IUIN JCI'CVIIiCJ 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com rAA 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIREC 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY V d. � U U) w ��— O o C/) O >' CU CCU � a5 U (3) W o ca o Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: WIRELESS & AUDIO-VISUAL SYSTEMS - FIRST 'FLOOR PLAN U N ¢Sheet Numl--r: ca TS301 a lY CD Y d DS DS DS N O C N .Y C F) 0 W 4 N U 0 2 M Q ry W CL rn O 00 (p CV O N O C3) DS l:- DS DS DS a a ❑ D i S DS LA - . --- .. -:. .. kd j. DS I-. - , , f � . , .. ,• ... , ,.• ...II �( I• �.� ...�1 11III�........ ..:_ . _ ... IIIIIII� .,.. ..�III11\ �/�1 I ��',1. I111_ , 1�_ � ........ .. .: � I : I I ,. • ::'.•;'�`•I IL� . :•'_;: , :-•'1��1 III I I ' COUNTRY KITCH 2082 11IIIIIt _ 1 rIq 1111 - Ihk�l;.,; .•,.....:..-•:..1I _ • S9. L � I D 1 LAUN RY - 2007-_ I ' - -.58. uoa 8 3 i s It a l I . I • -- "tip-G—' i=8&t f - p I I -- - - - - MC•SP - I J - '2aa3 D DS D 1 i DS DS DS DS DS DS DS DS DS DS DS DS U) 0 U) 0 GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MA TRIX. C.TE I RMINATE DISTRIBUTED AUDIO SYSTEM LING B IN THIS AREA AT EQUIPMENT IN CA TELECOMMUNICATIONS ROOM IT 1025. 'SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com s Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIREC 6767 North Industrial Road Milwaukee Wl 53223 844.4APTU RA c. 2019 DIRECT SUPPLY Neo CCU d. co CD D U L L O W W � v J nO CU V ICU (15 w U L O CU 0 a = o Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: WIRELESS & AUDIO-VISUAL SYSTEMS - SECOND 'FLOOR PLAN U N Q Sheet Number: U CCU QTS302 Y C EMERGENCY CALL SYSTME - SECOND FLOOR SCALE: 3/32" = V-0" 7,rVSUMMIT SMITH D/ H VEL OPMENT 241 N. Broadwav OE BS _ 000 O BS O BS OE BS OE BS O UT -a`: K n CK i CK� EMERGENCY CALL SYSTEM - LOWER LEVEL SCALE: 3/32" = V-0" F� N 0 C N rn I 0 Ch IL w 45 0 U 0 M Q ry 0- AbI N 00 O N O N OO EE BS BS O GENERAL NOTES: A. REFERENCE SHEET TS000 FOR; GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR; SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. E.C. SHALL PROVIDE 4"X4" 1-GANG JUNCTION BOX ABOVE THE CEILING SPACE FOR THE INSTALLATION OF THE EMERGENCY CALL WIRLESS REPEATER. REPEATER DEVICE REQUIRES 120V HARDWIRED EME=RGENCY POWER CONNECTION TO EACH TRANSFORMER. APPROVED EMEGENCY CAL PROVIDER SHALL SUPPLY HARDWIRED TRANSFORMER DEVICE FOR INSTALLATION. APPROVED EMERGENCY CALL PROVIDER SHALL BE RESPONSIBLE FOR FINAL CONNECTION FROM TRANSFORMER TO WIRELESS REPEATER. 2. UNIVERSAL TRANSMITTER (UT) SHALL BE INTEGRATED TO DOOR CONTACT (DC) UT OUTPUT OF ACCESS CONTROL SYSTEM. INTEGRATION SHALL PROVIDE DOUR STATUS E O MONITORING THROUGH EMERGENCY CALL SYSTEM. 3. INSTALLATION OF EMERGENCYCALL SYSTEM SHALL INCLUDE FINAL LAYOUT AND COORDINATION OF SERVER, NETWORK COORDINATOR, PAGING BASE, RADIO REPEATER 1 0 AND RADIO REPEATER 2. EACH COMPONENT SHALL BE PROVIDED WITH UPS BATTERY CK BS E BACKUP AND 120V EMERGENCY F30WER CONNECTION. BS O E CK E CK BS O OK E BS Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com A I CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIRECT ` 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " S ) U L O W W -� O vJ no V / CIO U Q) 0CD w U CZ o a= o Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: EMERGENCY CALL SYSTEM - LOWER LEVEL PLAN N U N U ¢Sheet Number: U N A CU N C d Q 0 F N O .�L C CU I 0 1-7 21 Lu 0 U O Q ry -L E U n N 00 O C14 O N 0 EMERGENCY CALL SYSTEM - FIRST FLOOR i CK HT �i. E CK EE CK ABS OE GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. E.C. SHALL PROVIDE 4"X4" 1-GANG JUNCTION BOX ABOVE THE CEILING SPACE FOR THE INSTALLATION OF THE EMERGENCY CALL WIRLESS REPEATER. REPEATER DEVICE REQUIRES 120V HARDWIRED EMERGENCY POWER CONNECTION TO EACH TRANSFORMER. APPROVED EMEGENCY CAL PROVIDER SHALL SUPPLY HARDWIRED TRANSFORMER DEVICE: FOR INSTALLATION. APPROVED EMERGENCY CALL PROVIDER SHALL BE RESPONSIBLE FOR FINAL CONNECTION FROM TRANSFORMER TO WIRELESS REPEATER. 2. UNIVERSAL TRANSMITTER (UT) SHALL BE INTEGRATED TO DOOR CONTACT (DC) OUTPUT OF ACCESS CONTROL SYSTEM. INTEGRATION SHALL PROVIDE DOOR STATUS MONITORING THROUGH EMERGENCY CALL SYSTEM. 3. INSTALLATION OF EMERGENCY CALL SYSTEM SHALL INCLUDE FINAL LAYOUT AND COORDINATION OF SERVER, NETWORK COORDINATOR, PAGING BASE, RADIO REPEATER 1 AND RADIO REPEATER 2. EACH COMPONENT SHALL BE PROVIDED WITH UPS BATTERY BACKUP AND 120V EMERGENCY POWER CONNECTION. FOR DOOR SCHEDULE J"SUMMIT SMITH DE VEL O.PMENT 241 N, Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 1Cm D 03M�Tm CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIREC 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY " d- � U L O w O (D c CCS � Q) w U S� OCIO CD 0 aiCD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: EMERGENCY CALL SYSTEM - FIRST FLOOR PLAN U Q Sheet Number: U Cn TS401 Y C 0 SCALE: 3/32" = V-0" I f� N O Y C N .Y I 0 Ch F7 W 0 U 0 .0 CU _ Q WN U lei N M 00 O N O N O a LAUNDRY - 2044.- B`' B`Ci C�BiS , E, BS 71 i, , .. ....... .i 11r .� �i u� ;. Jii ur ._�yi :.. , ... .-.� . it .. ,IF . a i i� �a it ... •;. ,.. ..,�, .ii- _ ..., .. .. ... i ..-�, i ; :..: • .-i r� •- . - :. i i i, �-------n - a i 0 EMERGENCY CALL SYSTME - SECOND FLOOR 1 SCALE: 3/32" = V-0" GENERAL NOTES: A. REFERENCE SHEET TS000 FOR GENERAL NOTES, SYMBOLS, ABBREVIATIONS & SHEET INDEX. B. REFERENCE SHEET TS001 FOR SYSTEMS EQUIPMENT LEGEND & SCOPE MATRIX. KEYED NOTES: 1. E.C. SHALL PROVIDE 4"X4" 1-GANG JUNCTION BOX ABOVE THE CEILING SPACE FOR THE INSTALLATION OF THE EMERGENCY CALL WIRLESS REPEATER. REPEATER DEVICE REQUIRES 120V HARDWIRED EMERGENCY POWER CONNECTION TO EACH TRANSFORMER. APPROVED EMEGENCY CAL PROVIDER SHALL SUPPLY HARDWIRED TRANSFORMER DEVICE FOR INSTALLATION. APPROVED EMERGENCY CALL PROVIDER SHALL BE RESPONSIBLE FOR FINAL CONNECTION FROM TRANSFORMER TO WIRELESS REPEATER. 2. UNIVERSAL TRANSMITTER (UT) SHALL BE INTEGRATED TO DOOR CONTACT (DC) OUTPUT OF ACCESS CONTROL SYSTEM. INTEGRATION SHALL PROVIDE DOOR STATUS MONITORING THROUGH EMERGENCY CALL SYSTEM. 3. INSTALLATION OF EMERGENCY CALL SYSTEM SHALL INCLUDE FINAL LAYOUT AND COORDINATION OF SERVER, NETWORK COORDINATOR, PAGING BASE, RADIO REPEATER 1 AND RADIO REPEATER 2. EACH COMPONENT SHALL BE PROVIDED WITH UPS BATTERY BACKUP AND 120V EMERGENCY POWER CONNECTION. fl"SUMMIT SMITH DEVELOPMENT 241 N• Broadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD mm�Tm hiVIVS I rCUC I IVIV SEKVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 turn® DIREC 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " C00 L O W W y_ O O c / C— Qi L � LU L C O a = O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: EMERGENCY CALL SYSTEM - SECOND FLOOR PLAN U C_ U Sheet Number: U (U elf .Y TS402 d 0 rIN R N O C N `1 I 0 Ch w 0 U 0 M Q E 2k ME FINISH FLOOR MAGNETIC LOCK MASTER RELEASE DETAIL SCALE: 1 1/2" = 1'-0" GENERAL NOTES: A. E.C. SHALL PROVIDE SINGLE GANG BOX, MOUNTED AT 42" AFF AND 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE FOR INSTALLATION OF MAGNETIC LOCK MASTER RELEASE. ROCKER SWITCH SETTINGS * 1 n OFF7 2 SECOND n 2 ON NUIS SANCE 6� 3 ON NUISANCE ALERT 4 ON AUTO RELOCK WR 5 OFF NA 6 OFF NA ® 7 OFF UNLOCK ALERT 8 ON DEL ENABLED O66633i 0000 0o O �� O 000 00 0 * FIELD JUMPER INSTALLED BY THE E.C. DURING INSTALLATION. KEYED NOTES: 1.POWER INPUT - 12/24DC UL294 LISTED, POWER LIMITED, CLASS, POWER SUPPLYMUST BE USED. 2. FIRE ALARM INPUT - APPLY A NORMALLY CLOSED DRY CONTACT OR A JUMPER IF NOT CONNECTED TO FIRE ALARM. 3. RESET INPUT - DRY CONTACT CLOSURE RESETS LOCK IN ALARM CONDITION 4. RELEASE INPUT - DRY CONTACT CLOSURE WILL RELEASE LCOK FOR THE TIME DELAY PERIOD. 5. AUXI1_1 ARY INPUT - NORMAI I Y a osm r)RY rONITAr..T OR A JUMPER IF NOT USING. OPENING DRY CONTACT PLACES LOCK INTO DELAYED EGRESS COUNTDOWN. 6. ALARM OUTPUT - CONTACTS CHANGE STATE DURING AN ALARM CONDITION. 30V@1A RESISTIVE. DELAYED EGRESS MAGNETIC LOCK - TYPICAL SCALE: 1/8" = 1'-0" rrCKICDAI IUl1T0C. ADJACENT WALL UNSECURED SIDE FINISH FLOOR SECURITY 1 - DOOR V1001.2 (SET #01 B SCALE: NTS FUNCTION: FREE EGRESS ALL TIMES. FREE INGRESS DURING DAYTIME. ACCESS CONTROL KEYPAD AND SHALL PROVIDE AUTHORIZED INGRESS AFTER HOURS. SLIDING DOOR MANUFACTURER SHALL PROVIDE REQUIRED EQUIPMENT FOR INTEGRATION TO ACCESS CONTROL SYSTEM FOR DOOR STATUS MONITORING AND AFTER HOURS OPERATION. It KEYED NOTES: SUMMIT 1. CONDUIT AND PULL LINE TO ABOVE ACCESSIBLE CEILING OR LOCAL SMITH TELECOMMUNICATIONS ROOM PROVIDED BY DIVISION 26. PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. DEVELOPMENT 2. 4" X 4" DEEP BOX ABOVE ACCESSIBLE CEILING SPACE WITHIN 10' OF DOOR OPENING. WHERE DISTANCE TO ACCESSIBLE CEILING SPACE EXCEEDS 10', COORDINATE A 12" X 12" 941 N Rrr)ndwav CEILING ACCESS PANEL PROVIDED BY GENERAL CONTRACTOR. -.7 Suite 400 3. RECESSED SPST MAGNETIC DOOR POSITION SWITCH PROVIDED BY DIVISION 8. Milwaukee, WI 53202 CONDUIT AND PULL LINE TO BOX ABOVE ACCESSIBLE CEILING PROVIDED BY DIVISION 26. Phone: 414-453-0110 PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. Fax: 414-453-0112 4. NON -DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM Website: www.summitsmith.com CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 5. HANDS FREE INTERCOM SYSTEM. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN AC3CESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM�MY ���DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. /1/�\1t'1TP111nTI/�\1 /1r1"1\/1 /'11�n 6. DOOR BELL. DIVISION 26 SHALL PROVIDE 3/8" HOLE IN EXTERIOR FACADEAT 46" AFF UUN0 1 Kul. I IUN JCKv utzJ (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING 889 E. Johnson Street POWER, CONTROL, ,AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN Fond Du Lac, WI 54936 ACCESSIBLE CEILING SPACE. Phone: 920-924-2900 Fax: 920-924-2910 7. DOOR MANUFACTURER SHALL PROVIDE MORTAR GUARD BOX AS REQUIRED FOR Website: www.cdsmith.com CABLING. 8. NON -ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 9. DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 10. CREDENTIAL. READER. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX 209 South Water Street IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. Milwaukee, WI 53204 Phone: 414-359-3060 12. MULLION MOUNTED CREDENTIAL READER. PROVIDE ALL REQUIRED SYSTEM Fax: 414-359-3070 CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 17. ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 18. POWER TRANSFER HINGE PROVIDED BY DIVISION 8. DIVISION SHALL MAKE CABLING aptura. CONNECTIONS FROM ELECTRIFIED HARDWARE TO POWER TRANSFER HINGE. DIVISION 8 SHALL PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE DIRECT SUPPLY ALARM, FROM POWER TRANSFER HINGE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 6767 North Industrial Road DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY " UN -SECURED SIDE FINISH FLOOR SECURED SIDE CD O U L O U..I 4— O o cn N a CU CC5 C- O a� w U O ` v cc cD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL DETAILS c- U Q Sheet Number: TS500 O n N Cn 00 O CN O N O rn UN -SECURED SIDE FINISH FLOOR SECURED SIDE SECURITY 2A - DOOR V0001.2 (SET #01 C SCALE: 1" = 1'-0" FUNCTION: FREE EGRESS AT ALL TIMES. DOOR BELL WILL NOTIFY FOR REQUEST TO ENTER. ACCESS CONTROL CREDENTIAL READER SHALL TEMPORARILY DEACTIVATE ELECTRIFIED STRIKE ON ACTIVE LEAF TO PROVIDE AUTHORIZED INGRESS. RECESSED MAGNETIC DOOR POSITION SWITCHES WILL PROVIDE DOOR STATUS MONITORING. SECURITY 213 -DOOR 1017 (SET #01 C SCALE: 1" = 1'-0" FUNCTION: FREE EGRESS AT ALL TIMES. ACCESS CONTROL CREDENTIAL READER SHALL TEMPORARILY DEACTIVATE ELECTRIFIED STRIKE ON ACTIVE LEAF TO PROVIDE AUTHORIZED INGRESS. RECESSED MAGNETIC DOOR POSITION SWITCHES WILL PROVIDE DOOR STATUS MONITORING. N O Y C a) rn I 0 Cn F7 CD 2 21 W 0 a) U) co U L 0 2 0_ E: m NE n M M 00 O CN O N O 3/4" C. UNSECURED SIDE FINISH FLOOR SECURITY 3 -DOORS 1074 & 1098 (SET#01 D SCALE: 1" = V-0" FUNCTION: ACCESS CONTROL CREDENTIAL READER WILL DE -ENERGIZE MAGNETIC LOCK FOR AUTHORIZED INGRESS & EGRESS. RECESSED DOOR CONTACT SHALL PROVIDE DOOR STATUS MONITORING. 4" C. SECURED SIDE UN -SECURED SIDE FINISH FLOOR SECURED SIDE SECURITY 5 -DOORS C1005) C2006 (SET #02C SCALE: 1" = V-0" FUNCTION: DOORS LOCKED AT ALL TIMES. ACCESS CONTROL CREDENTIAL READER WILLTEMPORARILY DEACTIVATE MAGNETIC LOCK FOR EGRESS AND INGRESS TO AND FROM MEMORY CARE DINING TO CORRIDOR. RECESSED DOOR POSITION SWITCHES SHALL PROVIDE DOOR STATUS MONITORING. FINISHED CEILING FINISHED FLOOR SECURED SIDE SECURITY 4 - DOORS 1023.27 1026.27 1030.17 1030.27 104.17 1072 (S ET#01 E SCALE: 1" = V-0" FUNCTION: RECESSED DOOR CONTACT SHALL PROVIDE DOOR STATUS MONITORING. UN -SECURED SIDE SECURITY 6-DOOR C1010.2 (SET #02F SCALE: 1" = V-0" FINISH FLOOR SECURED SIDE FUNCTION: FREE EGRESS AT ALL TIMES. RECESSED DOOR CONTACT SHALL PROVIDE DOOR STATUS MONITORING. KEYED NOTES: 1. CONDUIT AND PULL LINE TO ABOVE ACCESSIBLE CEILING OR LOCAL TELECOMMUNICATIONS ROOM PROVIDED BY DIVISION 26. PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. 2. 4" X 4" DEEP BOX ABOVE ACCESSIBLE CEILING SPACE WITHIN 10' OF DOOR OPENING WHERE DISTANCE TO ACCESSIBLE CEILING SPACE EXCEEDS 10', COORDINATE A 12" X 12" CEILING ACCESS PANEL PROVIDED BY GENERAL CONTRACTOR. 3. RECESSED SPST MAGNETIC DOOR POSITION SWITCH PROVIDED BY DIVISION 8. CONDUIT AND PULL LINE TO BOX ABOVE ACCESSIBLE CEILING PROVIDED BY DIVISION 26. PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. 4. NON -DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 5. HANDS FREE INTERCOM SYSTEM. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 6. DOOR BELL. DIVISION 26 SHALL PROVIDE 3/8" HOLE IN EXTERIOR FACADEAT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 7. DOOR MANUFACTURER SHALL PROVIDE MORTAR GUARD BOX AS REQUIRED FOR CABLING. 8. NON -ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 9. DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 10. CREDENTIAL READER. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 12. MULLION MOUNTED CREDENTIAL READER. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 17. ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 18. POWER TRANSFER HINGE PROVIDED BY DIVISION 8. DIVISION SHALL MAKE CABLING CONNECTIONS FROM ELECTRIFIED HARDWARE TO POWER TRANSFER HINGE. DIVISION 8 SHALL PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM POWER TRANSFER HINGE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE: CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 19. PUSH BUTTON. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. '.SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D 9J�7� M CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 ap_ ura®IRECT 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA O 2019 DIRECT SUPPLY L O W UJI 4— 0 0 ^ rW c / r� i U L W N ` v CD C=:> a � CD Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL DETAILS c- U Q Sheet Number: C_ U Cn a CU IY TS501 /-) N O Y C I 0 U) 17 W 0 CU U O c� _ Q fy CL n M M 00 O N O N O 8 O SECURED SIDE SECURITY 7 - DOORS S2.02, S3.021 (SET#02J) SCALE: 1" = V-0" S 1.12, S4.127 S5.121 S6.12 FUNCTION: FREE EGRESS AT ALL TIMES, EXIT ONLY. RECESSED DOOR CONTACT SHALL PROVIDE DOOR STATUS MONITORING. FINISHED CEI 17 FINISHED FLOOR SECURITY 9�-D�OOR�SS�5. 11�,S 5.2�YS 6.11, S6.2 SET#02H-A 3 SCALE: 1" FUNCTION: CREDENTIAL READER WILL TEMPORARILY RELEASE DELAYED EGRESS MAGNETIC LOCK PROVIDING AUTHORIZED EGRESS. RECESSED MAGNETIC DOOR POSITION SWITCH SHALL PROVIDE DOOR STATUS MONITORING. 4 FINISH FLOOR MEMORY CARE SIDE SECURITY 8 -DOOR 1104.2 (SET#02F-B SCALE: 1" = V-0" FUNCTION: CREDENTIAL READER WILL TEMPORARILY RELEASE MAGNETIC LOCK TO PROVIDE AUTHORIZED EGRESS INTO THE MEMORY CARE LOBBY. RECESSED MAGNETIC DOOR POSITION SWITCHES WILL PROVIDE DOOR STATUS MONITORING. UNSECURED SIDE LOBBY SIDE FINISH FLOOR SECURITY 10 - DOORS 1035.37 10657 10947 2054, 2074 (SET#04B-B) SCALE: 1" = V-0" FUNCTION: ACCESS CONTROLCREDENTIAL SHALL DE -ENERGIZE ELECTRIFIED STRIKE FOR AUTHORIZED INGRESS. FREE EGRESS PROVIDED BY DOOR HARDWARE. RECESSED DOOR CONTACT SHALL PROVIDE DOOR STATUS MONITORING 1/2"C. V SECURED SIDE KEYED NOTES: u 1. CONDUIT AND PULL LINE TO ABOVE ACCESSIBLE CEILING OR LOCAL �3 1i� TE RY �''�'�P111 TELECOMMUNICATIONS ROOM PROVIDED BY DIVISION 26. PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. 241 N. Broadway 2. 4" X 4" DEEP BOX ABOVE ACCESSIBLE CEILING SPACE WITHIN 10' OF DOOR OPENING. Suite 400 WHERE DISTANCE TO ACCESSIBLE CEILING SPACE EXCEEDS 10', COORDINATE A 12" X 12" Milwaukee, WI 53202 CEILING ACCESS PANEL PROVIDED BY GENERAL CONTRACTOR. Phone: 414-453-0110 3. RECESSED SPST MAGNETIC DOOR POSITION SWITCH PROVIDED BY DIVISION 8. Fax: 414-453-0112 CONDUIT AND PULL LINE TO BOX ABOVE ACCESSIBLE CEILING PROVIDED BY DIVISION 26. Website: www.summitsmith.com PROVIDE ALL SYSTEM CABLING PIER MANUFACTURER'S RECOMMENDATION. 4. NON -DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 5. HANDS FREE INTERCOM SYSTEM. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG Cm D ������ DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM CONSTRUCTION SERVICES DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 889 E. Johnson Street 6. DOOR BELL. DIVISION 26 SHALL PROVIDE 3/8" HOLE IN EXTERIOR FACADEAT 46" AFF Fond Du Lac, WI 54936 (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING Phone: 920-924-2900 POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE Fax: 920-924-2910 CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. Website: www.cdsmith.com 7. DOOR MANUFACTURER SHALL PROVIDE MORTAR GUARD BOX AS REQUIRED FOR CABLING. 8. NON -ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 9. DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 10. CREDENTIAL READER. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK 209 South Water Street BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM Milwaukee, WI 53204 CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX Phone: 414-359-3060 IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO Fax: 414-359-3070 JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 12. MULLION MOUNTED CREDENTIAL READER. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. sh in ria 17. ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 18. POWER TRANSFER HINGE PROVIDED BY DIVISION 8. DIVISION SHALL MAKE CABLING CONNECTIONS FROM ELECTRIFIED HARDWARE TO POWER TRANSFER HINGE. DIVISION 8 6767 North Industrial Road SHALL PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE Milwaukee WI 53223 ALARM, FROM POWER TRANSFER. HINGE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 844.4APTURA DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE 2019 DIRECT SUPPLY CEILING SPACE. 19. PUSH BUTTON. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. C � U W 4— 0 � c A M N U (3) o W a i C:) Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL DETAILS C_ <Sheet Number: U .N co TS502 F N O �I 0 w 4- 0 CD U) U L O 2 ry Q CD a�i i UN -SECURED SIDE FINISH FLOOR SECURED SIDE SECURITY 11A - DOORS C0004, 1035.4, (SET #04J-A SCALE: 1" = V-0" FUNCTION: FREE EGRESS AT ALL TIMES. ACCESS CONTROL KEYPAD SHALL MOMENTARILY DISABLE THE ELECTIFIED STRIKE AND COORDINATOR TO PROVIDE AUTHORIZED INGRESS. RECESSED DOOR CONTACTS SHALL PROVIDE DOOR STATUS MONITORING. UN -SECURED SIDE FINISH FLOOR SECURED SIDE FINISHED CEILING FINISHED FLOOR U MEMORY CARE SIDE LOBBY SIDE KEYED NOTES: 1. CONDUIT AND PULL LINE TO ABOVE: ACCESSIBLE CEILING OR LOCAL TELECOMMUNICATIONS ROOM PROVIDED BY DIVISION 26. PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. 2. 4" X 4" DEEP BOX ABOVE ACCESSIBLE CEILING SPACE WITHIN 10' OF DOOR OPENING. WHERE DISTANCE TO ACCESSIBLE CEILING SPACE EXCEEDS 10', COORDINATE A 12" X 12" CEILING ACCESS PANEL PROVIDED BY GENERAL CONTRACTOR. 3. RECESSED SPST MAGNETIC DOOR POSITION SWITCH PROVIDED BY DIVISION 8. CONDUIT AND PULL LINE TO BOX ABOVE ACCESSIBLE CEILING PROVIDED BY DIVISION 26. PROVIDE ALL SYSTEM CABLING PER MANUFACTURER'S RECOMMENDATION. 4. NON -DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 5. HANDS FREE INTERCOM SYSTEM. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 6. DOOR BELL. DIVISION 26 SHALL PROVIDE 3/8" HOLE IN EXTERIOR FACADEAT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 7. DOOR MANUFACTURER SHALL PROVIDE MORTAR GUARD BOX AS REQUIRED FOR CABLING. 8. NON -ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 9. DELAYED EGRESS MAGNETIC DOOR LOCK. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM MAGNETIC LOCK TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 10. CREDENTIAL READER. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE.DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 12. MULLION MOUNTED CREDENTIAL READER. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 17. ELECTRIFIED DOOR HARDWARE PROVIDED BY DIVISION 8. 18. POWER TRANSFER HINGE PROVIDED BY DIVISION 8. DIVISION SHALL MAKE CABLING CONNECTIONS FROM ELECTRIFIED HARDWARE TO POWER TRANSFER HINGE. DIVISION 8 SHALL PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM POWER TRANSFER HINGE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 19. PUSH BUTTON. DIVISION 26 SHALL PROVIDE (1) SINGLE GANG DEEP BACK BOX AT 46" AFF (UNO) FOR MOUNTING OF DEVICE. PROVIDE ALL REQUIRED SYSTEM CABLING, INCLUDING POWER, CONTROL, AND FIRE ALARM, FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. DIVISION 26 SHALL PROVIDE CONDUIT FROM DEVICE TO JUNCTION BOX IN ACCESSIBLE CEILING SPACE. 7��1111Ji�1�,71 l �1r V JEL OP J11 � �V r 241 N. Broadwav ..... -. -_-... _, Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD g5LJ �/ LJ CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIRECT 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " Ln C � U 0 U) W c A ICU 0 2) W U U C v � ai 0 Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ACCESS CONTROL DETAILS 00 00 O CV N OO FUNCTION: FREE EGRESS AT ALL TIMES. ACCESS CONTROL KEYPAD SHALL MOMENTARILY DISABLE THE ELECTIFIED STRIKE AND COORDINATOR TO PROVIDE AUTHORIZED INGRESS. RECESSED DOOR CONTACTS SHALL PROVIDE DOOR STATUS MONITORING. SECURITY 11 B - DOORSC1009 (SET #04J-A SCALE: 1 " = V-0" FUNCTION: CREDENTIAL WILL TEMPORARILY RELEASE DELAYED EGRESS MAGNETIC LOCK PROVIDING AUTHORIZED EGRESS FROM MEMORY CARE. MAGNETIC DOOR POSITION SWITCH SHALL PROVIDE DOOR STATUS MONITORING. SECURITY 12 -DOORS 2100.2 (SET#02F-B-A SCALE: 1" = V-0" L U Q Sheet Number: TS503C6 d N 0 `1 C Y rn I W Ch 17 a) p w 4-- 0 a) U 0 Q ry E -a? i G LO M 00 0 N O N O J-HOOK BUSHING 1" CONDUIT STUBBED UP TO ABOVE NEAREST ACCESSIBLE CORRIDOR CEILING. RECESSED DOUBLE -GANG BOX, SINGLE GANG PLASTER RING. MATCH HEIGHT AFF WITH ELECTRICAL OUTLETS. � TELECOM/DATA OUTLET BOX SCALE: NTS NOTES: 1. RACEWAY TO BE EMT OR FLEXIBLE RACEWAY SYSTEM (SIMILAR TO CAPLON) 2. NO MORE THAN (2) 90° BENDS OR TOTAL 1800 BENDS.+ 3. PROVIDE PULL STRING 4. SIZED AS FOLLOWS: A. DATA, VOICE, TV = 1" B. ACCESS CONTROL, DOOR FRAME, CARD READER, & MAGNETIC LOCK = 3/4" C. DOOR POSITION SWITCH & AUDIO SPEAKER = 1/2" LOCAL ELECTRICAL PANELBOARD BUILDING STEEL NOT REQUIRED IF NO BUILDING STEEL CONDUITS AND SLEEVES LEGEND 3/0 TBB TO FLOOR ABOVE TO FLOOR BELOW OR MAIN ELECTRICAL SERVICE GROUND #6 (TYPICAL UNLESS NOTED OTHERWISE) CABLE SHIELD (IF REQUIRED) FIBER OPTIC CABLE SHIELD (IF REQUIRED) 12" 1/4" COPPER BUSBAR El 4" TELECOMMUNICATION GROUNDBAR CONNECTION DETAIL SCALE: NTS CABLE TRAY OUTSIDE OF TR CABLE RUNWAY AND CABLE TRAY IN TR EQUIPMENT RACKS (DO NOT DAISY CHAIN RACK GROUNDING BETWEEN RACKS) omo DOUBLE LUG CONNECTOR TGB TELECOMMUNICATIONS GROUNDING BUSBAR (TINNED COPPER, PRE -DRILLED WITH DOUBLE LUG HOLES) ' CRIMP STYLE IRREVERSIBLE CONNECTION (H-TAP) TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR CONDUCTOR, SPLICES AND LUGS BY (TINNED COPPER, PRE -DRILLED WITH DOUBLE LUG HOLES) ELECTRICAL CONTRACTOR CONDUCTOR, SPLICES AND LUGS BY LOW TBB TELECOMMUNICATIONS BONDING BACKBONE VOLTAGE CONTRACTOR (BARE, STRANDED COPPER) TELECOM ROOM GROUNDING DETAIL (TYP.) SCALE: NTS NOTES: 1. LOCAL ELECTRICAL PANEL BOARD IS THE PANEL BOARD FROM WHICH TR/MDF ELECTRICAL CIRCUITS ARE OBTAINED. 2. INSTALL ALL GROUNDING CONDUCTORS AS STRAIGHT AS POSSIBLE. USE LONG SWEEPS WHEN BENDS ARE REQUIRED. ALL BENDS TO B MADE TOWARDS ELECTRICAL ENTRANCE MAIN GROUND. 3. ALL #6 CONDUCTORS TO BE STRANDED COPPER WITH GREEN COLORED INSULATION. 4. WHEN ATTACHING TO STEEL OR PAINTED COMPONENTS, USE OBLONG THREADED SCREWS, SELF=TAPPING SCREWS, AND/OR STAR WASHES. REMOVE PAINT FROM SURFACES PRIOR TO BONDING CONDUCTORS. 5. CONNECTION TO BUILDING STEEL IS NOT REQUIRED IF NONE IS EXISTING DUE TO CONSTRUCTION TYPE. 6. E.C. TO BOND TO ROUND ALL EQUIPMENT PROVIDED BY E.C. NOTES: 1. TELECOMMUNICATIONS BONDING BACKBONE (TBB) SHALL BE ONE CONTINUOUS CONDUCTOR. DO NOT ATTACH DIRECTLY TO TELECOMMUNICATIONS GROUND BAR (TGB). DO NOT MAKE SHARP BENDS. DO NOT USE EXOTHERMIC T-WELD CONNECTIONS. 2. PRE -DRILLED FOR DOUBLE LUG CONNECTORS. TELECOMMUNICATION GROUNDBAR DETAIL SCALE: NTS NOTE: 1. PRE -DRILLED FOR DOUBLE LAG CONNECTORS TYPICAL TELECOMMUNICATIONS OUTLET D2 SCALE: 1" = V-0" KEY NOTES: 1. 2 PORT, SINGLE GANG COVERPLATE WITH LABELS AND MOUNTING HARDWARE. 2. MODULAR JACK, NON KEYED, EIGHT POSITION (4 PAIR). 3. BALANCED TWISTED PAIR (4 PAIR), HORIZONTAL CABLE TO LOCAL TELECOMMUNICATIONS ROOM PATCH PANEL. 4. 4-11/16" X 4-11/16" SQUARE, 2-1/8" DEEP OUTLET BOX, WITH SINGLE GANG ADAPTER RING. 5. NYLON PULL CORD TO ACCESSIBLE CEILING SPACE. 6. 1" CONDUIT (MINIMUM) ,WITH BUSHINGS ON BOTH ENDS, TO ACCESSIBLE CEILING SPACE. UNISTRU" STRAF UNISTRUT SLEEVE, SIZE AND n-ry SRAM 3" - 6" MAX ;E CAULK °AROUND cn-EEVE. TYP. FOR ALL. 2" AX CONE UNI NOTES: 1. BOND ALL RACEWAYS WITH A #6 GROUND WIRE. PROVIDE CONDUIT DOOR POSITION SWITCH & AUDIO SPEAKER = 1/2" GROUND BAR AND OTHER END TO CABLE TRAY ON FLOOR BELOW. 2. PROVIDE UL LISTED FIRE BARRIER TO MAINTAIN RATING OF FLOOR. CONDUIT SLEEVE THROUGH FLOOR DETAIL TYPICAL TELECOMMUNICATIONS OUTLET D1 KEY NOTES: 1. 1 PORT, SINGLE GANG COVERPLATE WITH LABELS AND MOUNTING HARDWARE. 2. MODULAR JACK, NON KEYED, EIGHT POSITION (4 PAIR). 3. BALANCED TWISTED PAIR (4 PAIR), HORIZONTAL CABLE TO LOCAL TELECOMMUNICATIONS ROOM PATCH PANEL. 4. 4-11/16" X 4-11/16" SQUARE, 2-1/8" DEEP OUTLET BOX, WITH SINGLE GANG ADAPTER RING. 5. NYLON PULL CORD TO ACCESSIBLE CEILING SPACE. 6. 1" CONDUIT (MINIMUM) ,WITH BUSHINGS ON BOTH ENDS, TO ACCESSIBLE CEILING SPACE. TYPICAL TELECOMMUNICATIONS OUTLET DETAILS TV SCALE: 1" = V-0" KEY NOTES: 1. 2 PORT, SINGLE GANG COVERPLATE WITH LABELS AND MOUNTING HARDWARE. 2. MODULAR JACK, NON KEYED, EIGHT POSITION (4 PAIR). 3. SERIES 6 (RG-6) F-CONNECTOR MODULAR INSERT (KEYSTONE STYLE). 4. BALANCED TWISTED PAIR (4 PAIR), HORIZONTAL CABLE TO LOCAL TELECOMMUNICATIONS ROOM PATCH PANEL. 5. SERIES 6 (RG-6) COAXIAL CABLE TO TELECOMMUNICATIONS ROOM FOR VIDEO DISTRIBUTION 6. NYLON PULL CORD TO ACCESSIBLE CEILING SPACE. 7. 4-11/16" X 4-11/16" SQUARE, 2-1/8" DEEP OUTLET BOX, WITH SINGLE GANG ADAPTER RING. 8. 1" CONDUIT (MINIMUM) ,WITH BUSHINGS ON BOTH ENDS, TO ACCESSIBLE CEILING SPACE. '.SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com "mICD CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com rAA 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIRECT SUPPLY 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY c S C- O W U s= W -� 4- 0 C0 A U L_ L O O L a' LiJ U S_ o O a = O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TELECOMMUNICATION DETAILS C_ U Sheet Number: TS504 �N a N .mac C d SCALE: NTS f� N O `1 C 0 Cb 21 > w a� ca U 0 tY Q ry ;_ N i U 73 n M 00 0 N 0 N O RM# - D01 RM# - D02 RM# - D03 RM# - D04 RM# - D05 CATEGORY 6 - CABLE LABELING DETAIL RM# - V01 RM# - V02 RM# - V03 RM# - VO4 RM# - V05 RM# - C01 RM# - CO2 RM# - CO3 RM# - C04 RM# - C05 RM# - W01 RM# - W02 RM# - W03 RM# - W04 RM# - W05 IATA CAT 6 VOICE CAT 6 CAN RG-6 / RG-11 WIRELESS CAT 6 A. LABEL ALL CATEGORY 6 AND FIBER OPTIC CABLES ON BOTH ENDS. B. THE OUTLET IDENTIFICATION SHALL BE PRINTED A MINIMUM OF THREE TIMES ON EACH LABEL. C. THE FIRST DIGITS REPRESENT THE IT ROOM NUMBER THAT THE PATCH PANEL RESIDES IN. D. THE LAST DIGITS REPRESENTS THE CABLE PORT NUMBER E. ALL LABELS ARE TO BE PERMANENT IN NATURE AND BE MACHINE GENERATED, HAND WRITTEN LABLES ARE NOT ACCEPTABLE. F. CABLING STANDARDS REPRESENT AT MINIMUM THE REQUIREMENTS FOR LABELING. ALL LABELING REQUIRED BY MANUFACTURER OR LOCAL STATE AUTHORITIES SUPERCEDE. G. PATCH PANEL IN EACH DATA CLOSET SHALL BE LABELED SEQUENTIALLY (1-48) TO (48-72). H. FACE PLATES SHALL BE LABELED BASED ON THE CLOSET DESIGNATION OR PATCH PANEL PORT. I. FOR INSTANCE: DATA CLOSET (IDF 1) - DATA PATCH PANEL PORT (D71) 1 - D71. J. FOR INSTANCE: VOICE CLOSET (IDF 2) - VOICE PATCH PANEL PROT (V71) 2 - V71. K. FOR INSTANCE: WIRELESS WAP (IDF 3) - WAP PATCH PANEL PORT (WAP 71) 3 - WAP 71. L. CABLE COLOR STANDARDS: 1. VIDEO - YELLOW 2. POE VOICE - WHITE 3. DATA - BLUE 4. WIFI - ORANGE 5. ANALOG PORTS - IVORY ,TELECOMMUNICATIONS CABLE LABELING SCALE: NTS TO APPROVED SERVICE PROVIDER ROUTER CAT6 PATCH CORD ADTRAN ROUTER GIG PORT /2 I.S.P. FEED ADTRAN GIG #3 GIG #2 GIG #1 ROUTER PROVIDED BY OPERATOR NON POE SWITCH MULTIMODE FIBER MULTIMODE FIBER TELECOMMUNICATIO FIBER FEED TO OTHER I.T. ROOMS ADMIN CAMERA NETWORK / POINT OF SALE CAT6 PATCH CORD ADTRAN ROUTER GIG PORT /1 ADMIN PHONE/DATA NETWORK BROWN WHITE/BROWN GREEN <_ TO PATCH PANEL WHITE/GREEN TERMINATION ORANGE WHITE/ORANGE J,, BLUE �1 WHITE/BLUE OG VOICE CABLE OG 11 DATA CABLE rzi71R•7:f��7►�i1►I�Ie�ri7�l OG 11 SURVEILLANCE CABLE TELECOMMUNICATIONS CABLE LABELING STANDARDS SCALE: NTS (1) CAT6 (2) CAT6 FHORIZ STA CABLE HORIZ STA CABLE 0 d o o STATION CABLE DATA DATA/DATA PATCH PANEL STATION STATION RACK MOUNT OUTLET DEVICE OUTLET DEVICE NON -POE NON -POE -CAT6 PATCH CORD CAT6 PATCH CORD CAT6 PATCH CORD POE - INJECTOR SHELF d LAN POE LAN POE LAN POE FIBER FEED TO OTHER I.T. ROOMS ADMIN PHONE/DATA NETWORK NS CABLE CONNE CAT6 PATCH CORD (2) CAT6 HORIZ STA CABLE (1) CAT6 HORIZ S T A CABLE (1) CAT6 HORIZ STA CABLE CCTV SECURITY CAMERA POE (1) CAT6 HORIZ STA CABLE - F� _ S- 60 _ O O o _�._yy��_yy ��yy .. qqq�. . �Fy� ram. F. F F FW F�� wo �v!h_L hl 6.d6.d6.d61f�S� 51.!.1S.dh.! h�6��!..A O O STATION CABLE PATCH PANEL WIRELESS RACK MOUNT ACCESS POINT POE BY SPECTRUM CAT6 PATCH CORD CTIONS DETAIL TELE/DATA STATION OUTLET DEVICE POE 0� CAT6 NETWORK TELE/DATA STATION POE POINT OF SAL PRINTE CAT 6 DATA CA CHASE BEHIN ELECTRICAL PANE PRO\ CONDUIT F DATA CABLE 1" CONDUIT BENEA FLOOR SLAB I U NEAREST FULL HEIGHT WALL FOR INSTALLATION OF CAT 6 DATA CABLES CHEFS TABLE ELE SCALE: NTS DATA 0 o a D1 0 TV 000 G a Tv 492-1 492-1 18" AFF O O O.C. E.C. PROVIDED DATA/TV OUTLET ELECTRICAL OUTLET SCALE: NTS 7 r3n M-r MATA !ll 1'TI r'Y 4" BENEATH CHEF'S TABLE VATI O N DETAIL a V1 a D2 DUAL DATA/VOICE OUTLET a D2 SINGLE DATA/VOICE DUAL PORT DATA OUTLET TELECOMMUNICATIONS DEVICE DETAIL SCALE: NTS • �r��e�u�we_ww�rrww�ww_au_ww_ww_wusw —w_ ►_a�ar�wu�tr_+��r�w�a • A W aD1 SINGLE PORT DATA VOICE/DATA ANALOG VOICE/DATA INTERCOM SUMMIT SMITH DEVELOPMENT 241 N. Broadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com 1CD 93M\/ �TX CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY " U W � L_ 0 O W 0 C A U N 0W U Q, = O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TELECOMMUNICATION DETAILS J J U N U <Sheet Number: C_ U N M NTS505 .Y d. SCALE: NTS ED f� 0 �c c a� rn I 0 Ch W 4- 0 U L 0 _ Q ry W a O IV: 00 O C14 O CV O 6 2 3 48" 4 IT DEMARK 4 0019 2 2 D1-48 12 18 Eq V1/D1 . 2 19 ID IT DEMARK 0019 SCALE: 1/2" = V-0" IT 1025 SCALE: 1/2" = V-0" IT 2012 SCALE: 1/2" = V-0" r, IT 0015 SCALE 1/2" = 1'-0" IT 1054 4 SCALE: 1/2" = 1'-0" IT 2043 SCALE: 1/2" = V-0" ID !I I, - —C'— — — nn 0 uu 2 4 11 5 19 I IT 1091 SCALE: 1/2" = V-0" IT 2079 SCALE: 1/2" = V-0" D1 AP GENERAL NOTES: A. EQUIPMENT SHOWN FOR DESIGN INTENT. CONTRACTOR SHALL PROVIDE EFFICIENT ARRANGEMENT OF EQUIPMENT IN EACH RACK AS REQUIRED BY SYSTEMS SERVED IN EACH TELECOM ROOM. I:,10rd 7�CGYM4 1. E.C. SHALL PROVIDE 4" CONDUIT SLEEVES (QUANTITY AS SHOWN) INTO CORRIDOR CEILING SPACE FOR CABLE DISTRIBUTION INTO TELECOMMUNICATION ROOM. PROVIDE BUSHINGS AND FIRE STOPPING AT EACH CONDUIT PENETRATION, AS REQUIRED. 2. G.C. SHALL PROVIDE 3/4" X 4' X 8' FIRE RATED, PAINTED PLYWOOD MOUNTED AT PERIMETER WALL AS SHOWN FOR MOUNTING OF SYSTEMS EQUIPMENT. 3. PROVIDE 2-POST OPEN FRAME, FLOOR MOUNTED RACK, 10-32 THREADED RACK. MIDDLE ATLANTIC, OR EQUAL. 4. 12 INCH LADDER RACK SHALL BE INSTALLED ABOVE 2-POST RACK. ALL NETWORK CABLES SHALL BE ATTACHED TO LADDER RACK. 5. GROUND BUS BAR. 6. PROVIDE MIN 4 INCH MOUNTED VERTICAL CABLE MANAGEMENT ON THE SIDE OF THE RACKING CONFIGURATION. MIDDLE ATLANTIC, OR EQUAL. 7. ACCESS CONTROL DOOR CONTROLLER AND POWER SUPPLY SHALL REQUIRE 120V EMERGENCY POWER CONNECTION AND DATA CONNECTION AS INDICATED: * MDF 1017 - E.C. SHALL PROVIDE (1) 120V EMERGENCY POWER QUAD OUTLET AT 24" AFF. LOW VOLTAGE CONTRACTOR SHALL PROVIDE (1) 2-PORT DATA OUTLET * IDF 153 - E.C. SHALL PROVIDE (2) 120V EMERGENCY POWER QUAD OUTLETS AT 24" AFF. LOW VOLTAGE CONTRACTOR SHALL PROVIDE (2) 3-PORT DATA OUTLETS AT 24" AFF. 8. PROVIDE (1) 120V NORMAL POWER DUPLEX RECEPTACLE: WITH (1) 1-PORT DATA OUTLET MOUNTED AT 48" AFF FOR AUDIO SYSTEM EQUIPMENT. REFERENCE TS508 & TS512 FOR ADDITIONAL INFORMATION. 9. INCOMING SERVICE CONDUIT. REFERENCE UNDERGROUND CONDUIT PLAN TS011 FOR ADDITIONAL INFORMATION. 10. CONDUIT PENETRATIONS FOR BACKBONE CABLING. SEE NOTE 1 ABOVE. 11. WALL MOUNTED, OPEN FRAME RACK WITH MIN. OF 30RMU SPACE. 12. AREA OF RESCUE ASSISTANCE CONTROL PANEL AND POWER SUPPLY. PROVIDE (1) 120V EMERGENCY POWER DUPLEX RECEPTACLE & 1-PORT ANALOG OUTLET. 13. BUZZ TIME SYSTEM EQUIPMENT. PROVIDE (1) NORMAL POWER DUPLEX OUTLET MOUNTED AT 24"AFF FOR BUZZ TIME UPS AND TRIVIA SYSTEMS EQUIPMENT. 14. PROVIDE (1) 3" CONDUIT FROM CEILING OF ROOM TO ROOF FOR FUTURE INSTALLATION OF LIFE SAFETY BI-DIRECTIONAL ANTENNA SYSTEM. REFERENCE SHEET TS508 FOR ADDITIONAL INFORMATION. 15. PROVIDE 3/4", Tx & FIRE RATED PLYWOOD MOUNTED AT 72" AFF FOR CABLE TV SERVICE PROVIDER EQUIPMENT. PROVIDE (1) 20A-1P, 120V NORMAL POWER DUPLEX RECEPTACLE AT 72" AFF. 16. E-CALL RADIO EQUIPMENT CHANNEL 2 17. E-CALL RADIO EQUIPMENT CHANNEL 1 18. E-CALL NETWORK COORDINATION AND SERVER EQUIPMENT 19. CABLE TV EQUIPMENT 20. FIRE ALARM RELAY FOR ELECTRIFIED LOCKING HARDWARE AND DEVICES PROVIDED BY FIRE ALARM CONTRACTOR. CONNECTIONS TO FIRE ALARM RELAY BY FIRE ALARM CONTRACTROR. 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 r1 L,Eiu T 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 2019 DIRECT SUPPLY " cz �. co � U o � L � W -� L4— 0 c A U W L ca o Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: ENLARGED TELECOMMUNICATION; ROOM DETAILS 01 Q Sheet Number: U N co r� N Y C 9 81 F� N O Y C N Y rn I 0 Cb I— CL W 46 0 U) U 0 Q ry A -rELECnnAnAi 1K11r_AT1r)NiS RISER nIAnPAnn SCALE: NTS KEYED NOTES: 1. HAND HOLE. SEE SHEET TS0011 FOR DETAILS. 2. UNDERGROUND TELECOMMUNICATION SERVICE ENTRANCE DUCTS. SEE SHEET TS0011 FOR DETAILS. 3. PROVIDE RG11 COAX 4. PROVIDE RG11 COAX, 25 PAIR MULTI -CONDUCTOR TWISTED PAIR TELEPHONE CABLE AND 12MM FIBER OPTIC CABLE. TELECOMMUNICATIONS GROUNDING RISER DIAGRAM SCALE: NTS TELECOM EQUIPMENT RACK DETAILS (TY IF P. SCALE: 1" = V-0" 241 N, Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com Cm D CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA L 2019 DIRECT SUPPLY " GENERAL NOTES: EQUIPMENT SHOWN FOR DESIGN INTENT. CONTRACTOR SHALL PROVIDE EFFICIENT ARRANGEMENT OF EQUIPMENT IN EACH RACK AS REQUIRED BY SYSTEMS SERVED IN EACH TELECOM ROOM. KEYED NOTES: 1 1. 12 INCH OVERHEAD CABLE RUNWAY SHALL BE INSTALLED ABOVE 2-POST RACK. ALL CU �. NETWORK CABLES SHALL BE ATTACHED TO LADDER RACK. OVERHEAD CABLE RUNWAY SHALL BE ATTACHED FIRMLY TO A MIN. OF (2 WALLS AND TOP OF 2-POST RACK. PROVIDE 3" SPACERS DOOR SWING, 3�:p ON RACK TO CLEAR USE ADDTITONAL SUPPORT BRACKETS C-p FROM WALL OR THREADED ROD FROM CEILINGS AS REQUIRED IFOR SUPPORT. C p 2. LOW VOLTAGE CONTRACTOR SHALL PROVIDE 6 INCH SINGLE SIDED VERTICAL CABLE MANAGEMENT. CHATWORTH PRODUCTS, MOTIVE SERIES, OR EQUAL. ( U 3. LOW VOLTAGE CONTRACTOR SHALL PROVIDE 19 INCH VERTICAL_ SLIM LINE SURGE POWER 0 STRIP (10 OUTLET) GEIST 20A-12OV, PDU. C/) 4. CISCO SG112 - 24 PORT, UNMANAGED NON POE SWITCH. (WIFI) 5. LOW VOLTAGE CONTRACTOR SHALL PROVIDE FIBER RACK MOUNTED ENCLOSURE 19", 1U. > FIBER PANEL SHALL INCLUDE 12 PORT PANEL WITH DUPLEX LC ADAPTER PLATES. FIBER TERMINATIONS SHALL BE LC 50/125 10G CORNING C95 SERIES OR EQUAL. W C_ 6. DUAL BAND INTERNET ROUTER - NETVANTA 3140 ADTRAN, FOR TELEPHONE SOLUTION. y_ O EQUIPMENT TO BE PROVIDED BY OWNERS APPROVED PHONE VENDOR. LOW VOLTAGE o U) CONTRACTOR SHALL PROVIDE (1) BLANK SHELF FOR PLACEMENT OF EQUIPMENT. 7. 24-PORT PATCH PANEL, KEYSTONE [CC SERIES, OR APPROVED EQUAL. CD 8. CISCO SG300 28PP 28-PORT GIGABIT POE MANAGED SWITCH (SURVEILLANCE). 9. MINUTEMAN POWER TECHNOLOGY ENTERPRISE PLUS E1500RU12U FOR SYSTEMS C EQUIPMENT (1500W, 120V UPS). PROVIDE (1) UPS PER TELECOMMUNICATIONS ROOM. N 10. CISCO SG300 28PP 28-PORT GIGABIT POE MANAGED SWITCH (PHONE, DATA AND POINT OF SALE), o N 11. DELL SERVER PROVIDED BY OPERATOR FOR SYSTEMS SOFTWARE. SHALL INCLUDE > LLJ MONITOR, KEYBOARD AND MOUSE. 12. ADURANT CLOUD BASED INTERNET ROUTER PROVIDED BY TECHNOLOGY PARTNERS. 13. CISCO EXPLORE HIGH DEFINITION SET TOP MULTI STREAM CABLE CARD INTERFACE. -�Cz = O � PROVIDED BY CABLE SERVICE PROVIDER. a 14. NETWORK VIDEO RECORDING EQUIPMENT FOR SURVEILLANCE SYSTEM. Issuance / Revisions 15. VOLUME CONTROL FOR DISTRIBUTED AUDIO THROUGH THE VAL.COM SYSTEM. 16. PROVIDE HORIZONTAL CABLE MANAGEMENT BETWEEN PATCH PANELS. Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: TELECOMMUNICATION; RISER DIAGRAMS 75 n O d' 00 O CV O CV O L U Q Sheet Number: C_ U CCU TS507 .mac d t� N O C N rn I 0 ch 2) W 0 U) ca U 0 2 M Q 2 a� fy E LWI SURVEILLANCE CAMERA - EXTERIOR WALL MOUNT SCALE: NTS KEYED NOTES: 1. E.C. SHALL PROVIDE 2-GANG WEATHER TIGHT OCTAGONAL BOX FOR FLUSH MOUNTED SURVEILLANCE APPLICATION. NETWORK COUPLER MUST BE ENCLOSED WITHIN A WATER TIGHT ENCLOSURE. 2. OCTAGONAL BOX MOUNTING PLATE. E.C. SHALL PROVIDE WEATHERPROOF GASKET. 3. SURVEILLANCE NETWORK COUPLER MUST BE INSTALLED WITHIN A WATER TIGHT ENCLOSURE. 4. CONDUIT PROVIDED BY DIVISION 26 SURVEILLANCE CAMERA -ACCESSIBLE CEILING SPACE SCALE: 1/8" = V-0" KEYED NOTES: SURVEILLANCE CAMERA - EXTERIOR WALL MOUNT WITH BRACKET SCALE: NTS KEYED NOTES: 1. E.C. SHALL PROVIDE 2-GANG WEATHER TIGHT OCTAGONAL BOX FOR WALL MOUNT BRACKET. 2.WALL MOUNT BRACKET SHALL HAVE WEATHER TIGHT SEAL. 3. SURVEILLANCE NETWORK COUPLER MUST BE INSTALLED WITHIN A WATER TIGHT ENCLOSURE. 4. CONDUIT PROVIDED BY DIVISION 26 SURVEILLANCE CAMERA -INACCESSIBLE CEILING SPACE SCALE: 1 /8" = V-0" KEYED NOTES: 1. SURVEILLANCE DOME CAMERA 1. SURVEILLANCE DOME CAMERA. 2. NETWORK FEMALE 8P8C CONNECTOR FOR ETHERNET CONNECTION. 2. SINGLE GANG MUD RING BY DIVISION 26. 3. SURVEILLANCE CAMERA MOUNTING PLATE FOR INTERIOR ACCESSIBLE CEILING 3. NETWORK FEMALE 8P8C CONNECTOR FOR ETHERNET CONNECTION. APPLICATIONS. 4. RECESSED SINGLE GANG BOX FOR MOUNTING PROVIDED BY DIVISION 26. 4. SINGLE GANG BOX FOR MOUNTING PROVIDED BY DIVISION 26. 5. CONDUIT PROVIDED BY DIVISION 26. SUREVEILLANCE CAMERA SCHEDULE CAMERA NO. DEVICE LOCATION MANUFACTURER MODEL CAMERA DESCRIPTION LENS IR VIEWING RANGE - ANGLE OF VIEW FPS POWER REQ VOLTAGE MOUNTING HEIGHT ACCESSORIES NOTES ROOM NUMBER ROOM NAME 100 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 180' 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 101 C0001 VEST AXIS M3037-PVE 5MP MINI DOME 2.8 MM 30M - 180' 12 POE 5W, 12V GYP. CEILING 8' - 8" 102 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 180' 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 103 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 180' 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 104 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 180' 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 105 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 180° 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 106 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 1800 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 107 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 1800 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 108 - EXTERIOR AXIS M3037-PVE 5MP MINI DOME 4MM 30M - 1800 12 POE 5W, 12V EXTERIOR WALL 9' - 6" 109 C1001 VEST AXIS M3037-PVE 5MP MINI DOME 2.8 MM 30M - 1800 12 POE 5W, 12V GYP. CEILING 9' - 0" PPTSUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD ffMU7� CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 ap_ ura. 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY 10.1-9 OCU � CU i a, U a) O L > w U rt N ` �+ .� 0 a T_ Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: SURVEILLANCE SCHEDULES & DETAILS Ui U a> U <Sheet Number: C_ U c coTS508 Y c 00 O CV O N O a r�SUMMIT jD)1�° YEE Z 0PMENT VIFVTT-ERIEV\V Vn r\7S VOICE DIALER -1- (1) PR #22 AWG PER POINT PRESS ZONE BUTTON TO ANSWER CALL AND ACTIVATE INTERCOM PRESS ZONE BUTTON AGAIN TO TURN INTERCOM OFF IF LINE FAULT LIGHT IS ON CONTACT SERVICE PERSONNEL 0000000000 0000000000 0000000000 0000000000 0000000000 PUSH ® RELEASE TO TALK TO LISTEN ZONE 4F INTERCOM ON LINE FAULT `ZONE CALL POWDER ON RESET ALL ZONES I —INTERCOM ON ZONE5n LINE FAULT ® `ZONE CALL 2PR TWISTED #22 AWG INTERCOM ON ZONE 1 LINE FAULT `ZONE CALL rINTERCOM ON ZONE2n LINE FAULT `ZONE CALL ZONE 3n .--INTERCOM ON LINE FAULT `ZONE CALL ZONE 6n ,INTERCOM LINERFU AO TON `ZONE CALL PROVIDE 12V LIFE SAFETY CIRCUIT WITH NEUTRAL AND GROUND CONDUTCTOR FOR CONTROL CABINET OPERATION TWO -COMMUNICATION RISER DIAGRAM SCALE: NTS F� 0 c m 0 co IL ID IM w 0 W Cn U 0 _ Q fy N i L 2-WAY COMMUNICATION CALL RECEIVED 0 WHEN LIGHT O O FLASHES O 0 OOp PUSH FOR HELP 2-WAY COMMUNICATION CALL RECEIVED 0 WHEN LIGHT O 0 FLASHES 0 0 opp O PUSH FOR HELP fle'%RAR � WAY T I/1A1 %.vIVnVIvry k1/_% I Iv1� CALL RECEIVED p WHEN LIGHT 0 0 FLASHES O 0 Opp O PUSH FOR HELP 2-WAY COMMUNICATION CALL RECEIVED p WHEN LIGHT 0 0 FLASHES O 0 Opp O PUSH FOR HELP 2-WAY COMMUNICATION CALL RECEIVED p WHEN LIGHT O 0 FLASHES O 0 Opp O PUSH FOR HELP 2-WAY COMMUNICATION CALL RECEIVED p WHEN LIGHT 0 0 FLASHES O 0 Opp O PUSH FOR HELP (1) PR #18AWG BATTERY BACK-UP POWER SUPPLY 24VDC @ 3.5A FNOTE: NO CONDUIT OR WIRE INTO BOTTOM OF CABINET, BECAUSE OF BATTERIES THIRD FLOOR SECOND FLOOR 120 VAC, 60HZ @ 1.15A DEDICATED LIFE SAFETY CIRCUIT WITH NEUTRAL AND GROUND L_ - - (OPTIONAL) WIRING TO FIRE ALARM MONITORING (1) PR#18 AWG FIRST FLOOR 2-WAY COMMUNICATION TYPICAL MOUNTING HEIGHTS SCALE: NTS 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com CD l^iV VSI-t�VIi-I IV V SEf�CVI^iES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. DIRE(- 6767 North Industrial Road Milwaukee W153223 844.4APTU RA 2019 DIRECT SUPPLY " 04PA" C CD U CL CD W 0 O C/) c Qi U L � .1.1 Lu 'j) CIO � a = � Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: AREA OF RESCUE ASSISTANCE RISER DIAGRAM N d' co O N O N O U C_ Sheet Number: U Cn T TS509 CU c 15u1X'INT IT, f., ACTIVITY 2093 ACTIVITY 2001/CORR C2001 WELLNESS 2025 MC DINING 1074 ACTIVITY 1098 FORMAL DINING 1031 SUNROOM 1072/LOUNGE 1073 AL DINING 1030 GRAND LOBBY 1001/13ISTRO 1017 V5 $ ACTIVITY 2093 V5 ACTIVITY 2001 V5 $ 0 0 0 0 0 0 0 0 0 o S7 0 o S7 0 o S7 0 o S7 0 L::� 0 o 0 0 0 0 0 0 NTH a00kq17cb`yilyl0 V5 COUNTRY KITCHEN 1092 V5 ACTIVITY 1098 V4 STOR 1029 V3 STOR 1029 V2 STOR 1029 V1 BISTRO 1017 DISTRIBUTED AUDIO SYSTEM SCALE: 12" = V-0" GENERAL NOTES: A. AUDIO SYSTEM POWER SUPPLY. SOURCE CONNECTION AND MAIN VOLUME CONTROL SHALL BE LOCATED WITHIN MDF ROOM 1017. B. VOLUME CONTROLS SHALL BE PROVIDED AT EACH ZONED AREA TO PROVIDE INDIVIDUAL ZONE VOLUME CONTROL. EACH VOLUME CONTROL SHALL BE HOMERUN BACK TO MDF ROOM 1017 WITH CAT 6 CABLING. COORDINATE EXACT WIRING REQUIREMENTS WITH APPROVED VENDOR. C. VOLUME CONTROL SHALL PROVIDE VOLUME UP/DOWN AND ON/OFF, AT EACH ZONED LOCATION. D. AUDIO SOURCE SHALL BE (2) PRE -DETERMINED CABLE NETWORK INSERT MUSIC CHANNELS FOR SOUND DISTRIBUTION. COORDINATE REQUIREMENTS WITH APPROVED SERVICE PROVIDER. DISTRIBUTED AUDIO SCHEDULE DESIGNATION ROOM NUMBER ROOM QUANTITIY Manufacturer Model Description Mounting Height S1 CLG 1001 GRAND LOBBY 7 RECESSED CEILING SPEAKER 8' - 0" S1 CLG 1017 BISTRO 2 RECESSED CEILING SPEAKER 8' - 0" S2 WALL 1030 DINING 5 RECESSED WALL SPEAKER 8' - 0" S3 CLG 1072 SUNROOM 1 RECESSED CEILING SPEAKER 8' - 0" S3 CLG 1073 LOUNGE 1 RECESSED CEILING SPEAKER 8' - 0" S4 CLG 1031 FORMAL DINING 3 RECESSED CEILING SPEAKER 8' - 0" S5 CLG 1098 ACTIVITY 4 RECESSED CEILING SPEAKER 8' - 0" S6 CLG 1074 MC DINING 6 RECESSED CEILING SPEAKER 8' - 0" S7 CLG 2025 WELLNESS 4 RECESSED CEILING SPEAKER 8' - 0" S8 CLG 2001 ACTIVITY 1 RECESSED CEILING SPEAKER 8' - 0" S8 CLG C2001 CORR 4 RECESSED CEILING SPEAKER 8' - 0" S9 CLG 2093 ACTIVITY 4 RECESSED CEILING SPEAKER 8' - 0" S9 WALL 2093 ACTIVITY 2 RECESSED WALL SPEAKER 10' - 6" V1 SWITCH 1017 BISTRO 1 VOLUME/SOURCE CONTROL SWITCH 3' - 10" V2 SWITCH 1029 STOR 1 VOLUME/SOURCE CONTROL SWITCH 3' - 10" V3 SWITCH 1029 STOR 1 VOLUME/SOURCE CONTROL SWITCH 3' - 10" V4 SWITCH 1029 STOR 1 VOLUME/SOURCE CONTROL SWITCH 3' - 10" V5 SWITCH 1098 ACTIVITY 1 VOLUME/SOURCE CONTROL SWITCH 3' - 10" V6 SWITCH 1092 COUNTRY KITCHEN 1 VOLUME/SOURCE CONTROL SWITCH T - 10" V7 SWITCH 2O25 WELLNESS 1 VOLUME/SOURCE CONTROL SWITCH 3' - 10" V8 SWITCH 2 2001 ACTIVITY 1 VOLUME/SOURCE CONTROL SWITCH T - 10" V9 SWITCH 2O93 ACTIVITY 1 VOLUME/SOURCE CONTROL SWITCH T - 10" DUALGANG BOX AT 60" AFF DUALGANG BOX AT 60" AFF DUALGANG BOX AT 60" AFF DUPLEX DUPLEX DUPLEX RECEPTACE AT 60" AFF � TV OUTLET RECEPTACE AT 60" AFF � F RECEPTACLE 60" AFF r TV OUTLET TV OUTLET I I� (1) 1" CONDUIT I I� (1) 1"CONDUIT I I� (1) 1" CONDUIT DUPLEX RECEPTACLE AT 18" AFF DUPLEX RECEPTACLE DUPLEX RECEPTACLE _ AT18"AFF AT18"AFF DUALGANG BOX AT 18" AFF DUALGANG BOX AT 18" AFF DUALGANG BOX AT 18" AFF WII BOWLING SCALE: 3/4" = V-0" 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com C® M�T� MY CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY " Ne U 0) Cf) LU y._ O N C L O � LU O Issuance / Revisions Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: AUDIO-VISUAL SCHEDULE & DETAILS n M d- 00 O CV O N O C-1t7 C_ U <Sheet Number: C_ U Cn TS51 0 CU N C 0— Q Al 0 [7��S1MMIT SMITH DE VTe, L OPMENT N O C O I 0 IL 2 w 0 Cn U L O cu 1 ry a ry i U a M d' co O C"i O N O T CONCRETE SLAB u o11 CEILING LEVEL EMERGENCY CALL REPEATER ABOVE ACT CEILING — TYPICAL MOUNTING DETAIL SCALE: NTS KEYED NOTES: 1. 4"X4" JUNCTION BOX WITH HARDWIRED EMERGENCY POWER, ABOVE CEILING FOR HARDWIRED CONNECTION TO EMERGENCY CALL REPEATER TRANSFORMER PROVIDED BY DIVISION 26.. REFERENCE FLOOR PLANS FOR DEVICE LOCATION. REPEATERS SHALL BE LOCATED WITHIN 5' OF PLACEIVIEN I SHOVO4 ON FLOOR PLANS FOR ADEQUATE COVERAGE. 2. REPEATER SHALL NOT BE MOUNTED WITHIN 18" OF MECHANICAL DUCTWORK/PIPING. COORDINATE WITH LOCATION OF MECHANICAL SYSTEM PRIOR TO INSTALLATION OF POWER SOURCE. REPEATER PROVIDED BY PAACARE VENDOR. 3. PROVIDE (1) 120V EMERGENCY POWER CONNECTION TO EACH REPEATER LOCATION. DEDICATED CIRCUIT NOT REQUIRED. 4. 120V EMERGENCY POWER CONNECTION TO HARDWIRED TRANSFORMER SHALL BE PROVIDED BY DIVISION 26. TRANSFORMER SHALL BE FURNISHED TO DIVISION 26 BY PALCARE VENDOR FOR INSTALLATION BY DIVISION 26 EMERGENCY CALL TYPICAL DEVICE MOUNTING SCALE: 12" = V-0" KEYED NOTES: 1. BEDSIDE STATION. 2. 1-GANG, DEEP BOX PROVIDED BY DIVISION 26 FOR TOILET STATION. 3. 1-GANG, DEEP, PVC BOX PROVIDED BY DIVISION 26, FOR WATER RESISTANT EMERGENCY PULL CORD SHOWER STATION AND COVERPLATE WITH WEATHERPROOF GASKET. COORDINATION COLOR AND FINISH OF COVERPLATE WITH APPROVED FACILITY STANDARDS. CEILING DECK OR r-rm I I llTI I M C MC CABLE REPEATER OUT GYP HARD CEIL L- 120V EMERGENCY POWER Q PAGING BASE EPEATER JTLET WIRELESS RECEIVER qLL STUDS 120V EMERGENCY �I o aabb �— © POWER ® (1) DATA PORT LAN CONNECTION EMERGENCY CALL REPEATER RECESSED WALL MOUNT I YPICAL SCALE: NTS GENERAL NOTE: A. AS SHOWN ON FLOOR PLANS AT GYP. CEILING KEYED NOTES: 1. EC TO PROVIDE LEVITON 47617-REB & LOW PROFILE COVER 003-47617-LPF WITH LONG SIDE MOUNTED VERTICALLY TO WALL STUD. PROVIDE POWER TO SIDE OF RECESSED BOX AT KNOCKOUT. 2, RFPFATER AND TRANSFORMER PRO\/inFn BY PAl CARF, REPEATER MOUNTED IN AND ORIENTATION. 3. EC TO PROVIDE DUPLEX (EMERGENCY) POWER OUTLET IN SODE OF BOX FACING INWARD ELEC 1013 MDF 1017 ) 8 RADIO RADIO 8 0 CJ 0 BASE #1 BASE #2 8 n 120V EMERGENCY POWER RS485 SERIAL CABLE a EMERGENCY — CALL SERVER WIRELESS PAGING RECEIVER BASE D-TAP POWER DATA 2-24VDC LED PORT Q 0 M CAT 6 1� RS232 SERIAL' FF' PORT FAC P (BY OTHER) EMERGENCY CALL TO FIRE ALARM CONTROL PANEL IIVTEGRA I IVIN DE I AIL FIRE PANEL RS232 INTERFACE SERIAL PORT DATA DATA PORT LED PORT E2> ffi A O EMERGENCY POWER CAT 6 (1) DUAL DATA PORT® LAN CONNECTION SCALE: NTS GENERAL NOTES: A. DETAIL FOR INTENT PURPOSES ONLY. FINAL SYSTEM INSTALLATION AND ALL INTEGRATIONS SHALL BE COORDINATED WITH APPROVED MANUFACTURERS. KEYED NOTES: 1. FIRE ALARM CONTRACTOR SHALL PROVIDE (1) RS232 PORT WITHIN APPROVED FIRE ALARM CONTROL PANEL FOR CONNECTION TO FIRE PANEL INTERFACE (FPI) TO ALLOW INTEGRATION INTO EMERGENCY CALL SERVER, 2. FIRE PANEL INTERFACE DEVICE SHALL BE LOCATED WITHIN 10' OF THE APPROVED LOCATION OF THE FIRE ALARM CONTROL PANEL. 3. LOW VOLTAGE CONTRACTOR SHALL PROVIDE RS485 CABLE, AND CONNECTION FROM FPI TO APPROVED FIRE ALARM CONTROL PANEL LOCATIONS. CONNECTION TO THE FIRE ALARM CONTROL PANEL SHALL BE PERFORMED BY FIRE ALARM CONTRACTOR. CABLE NOT TO EXCEED 25 FT. 4. FIRE PANEL INTEGRATION RELAY AND EMERGENCY CALL SERVER SHALL REQUIRE (1) SINGLE DATA PORT TO LAN CONNECTION FOR COMMUNICATION TO FIRE ALARM CONTROL PANEL. 5. E.C. SHALL PROVIDE (1) 20A-1P, 120V EMERGENCY POWER DUPLEX RECEPTACLE FOR FIRE PANEL INTERFACE RELAY. 6. E.C. SHALL PROVIDE (1) 20A-1 P, 120V EMERGENCY POWER DUPLEX RECEPTACLE FOR EMERGENCY CALL SERVER AND UPS EQUIPMENT. 7. PALATIUM CARE DEDICATED UPS. 8. EMERGENCY CALL RADIO BASE EQUIPMENT. 9. UPS DEDICATED FOR PALATIUM CARE RADIO BASE EQUIPMENT. E.C. SHALL PROVIDE (1) 120V EMERGENCY POWER DUPLEX RECEPTACLE. 241 N, Rrnadwav Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 vvegsite: www.summiismiin.com cm D WMV �Tm INNS I RUC I IVIV SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI53223 844.4APTU RA 2019 DIRECT SUPPLY O co O r U � s— o � N ^ ♦ \W r W y_ O v ^V pW� V i U CD L— C:) -&-A W CIO C) O = o a Issuance / Revisions Revision Date 1 1 Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: EMERGCY CALL DETAILS a J J N U N C) U QSheet Number: CU TS51 1 a N C ►R SHALL ROUTE RG-6 LOSET OR CABLE 'DINT TO SINGLE GANG [THIN RESIDENT DVIDE 6' SERVICE LOOP. RG6 WITH F-TYPE MEMORY CARE APARTMENT OUTLET CABLE TV SERVICES - MEMORY CARE APARTMENT CABLING TYPICAL SCALE: NTS P. L GENERAL NOTES: A. E.C. SHALL PROVIDE A SINGLE GANG JUNCTION BOX WITH MUDRING WITHIN EACH MEMORY CARE RESIDENT APARTMENT FOR INSTALLATION FOR CABLE TELEVISION OUTLET. ASSISTED LIVING BEDROOM OUTLET CABLE TV SERVICES - ASSISTED LIVING APARTMENT CABLING TYPICAL 1211 = 1'-0" GENERAL NOTES: A. E.C. SHALL PROVIDE A DUAL GANG JUNCTION BOX WITH A SINGLE GANG MUDRING WITHIN EACH ASSISTED LIVING RESIDENT APARTMENT BEDROOM. THIS WILL PROVIDE SPACE FOR THE CABLE TELEVISION SPLITTER DEVICE TO BE INSTALLED. MnAA r%1 I A M n1111 1 M KEYED NOTES: 1. 3'X3' PLYWOOD BACKBOARD FOR CABLE TELEVISION SPLITTER TERMINATIONS. 2. 20A-1P, 120V DUPLEX OUTLET FOR CABLE TELEVISION EQUIPMENT REQUIREMENTS. 3. CABLE TELEVISION APPROVDED SPLITTER DEVICES FOR DISTRIBUTION REQUIRED FOR EACH APARTMETN AND PUBLIC SPACE TELEVISION. 4. 3" CONDUIT PENETRATIONS INTO ROOM FOR CABLE DISTRIBUTION. 5. GROUNDING SHALL BE PROVIDED AS REQUIRED BY APPROVED SERVICE PROVIDER. CABLE TELEVISION INTERMEDIATE EQUIPMENT SCALE: NTS (.SUMMIT SMITH DEVELOPMENT 241 N. Broadway Suite 400 Milwaukee, WI 53202 Phone: 414-453-0110 Fax: 414-453-0112 Website: www.summitsmith.com co A I M5 M\-/ �Tx CONSTRUCTION SERVICES 889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910 Website: www.cdsmith.com 209 South Water Street Milwaukee, WI 53204 Phone: 414-359-3060 Fax: 414-359-3070 aptura. 6767 North Industrial Road Milwaukee WI 53223 844.4APTU RA 9019 DIRECT SUPPLY V KrP CU co 3: N U (D 0 W U O Issuance / Revisions Revision Date 1 1 Date & Issued For: 02-01-2019 ISSUED FOR CONSTRUCTION Sheet Name: MEDIA DISTRIBUTION DETAILS U N rr d' d' co O N O N O M V- U Q Sheet Number: U N a C6 CD N Y C TS512 =3 a.