Loading...
HomeMy WebLinkAbout1963-8-21 - 123 Mark Drive - Septic As BuiltFEE TO THE BUILDING DEPARTMENT Application N0.#3 ' / TOWN OF SOUTH WINDSOR Date AuguSt 21.3.963 I hereby apply for permit to build a sewage disposal system for a Residence (Residence,boarding house ,hotel ,etc.) Owned by M of:- IZ 3Andlocatedat I‘Iark Drive (lot #15 ) To be built by Medallion Hem es Inc of West Hartford Y in accordance with detailed information stated below Signed /Q//‘/ I .Estimated population of premises (present) 2.Description of premises (including number of bedrooms) 3 bedroom Raised Ranch No.Fixtures (Above basement):Water Closets l Urinals Lavatories l Location of well and underground water piping Method of obtaining or storing supply (Pumps ,tank ,etc.) 4.Character of soil at proposed location of leaching system,including depths of various strata (sand loam clay hardpan rock etc ——Use test pits) 5.Elevation of highest ground water O TO L M I 'r OF P lT (w1th reference to both present &future grade) Bath tubs l Showers Kitchen Sinks l Laundry Tubs Garbage Grinder List basement fixtures l laV-,l W-C. 3.Water Supply public Kind of Well (Public ,well ,spring ,cistern) Description of proposed system (Furnish drawings of same,with plot plan showing system including location,size ,grade and material of house sewer and locations of ground or surface water draigns ,wells and bodies of surface water.) Septic Tank Dimensions Capacity below flow line $000 Inlet and outlet arrangements Facilities for cleaning Distance from dwellings on same property Iz2",on adjoining property 73' Stone or gravel will be covered by e ”HER .Distance between (tar paper,salt hay) trenches 7‘?’ft.Distance from water supply onisame property‘\ ;on adjoining property 36K?sis/7174 a x. Secondary Treatment ,if other than soil absorption. Describe in detail and locate on map KENIG-H:l System was designed by Above information furnished by Z40 NORTH MA'N 5mm CROSSROADS PLAZA ""'WEST HARTFORD 7,CONN. No discharge of sewage or sewage effluent into any watercourse should be permittedWithoutapprovaloftheStateDepartmentofHealthandStateWaterCommission. Automatic Dosing Apparatus ,if any (describe) Soil Absorption System If cesspools ,No.',diameter ft.;depth below inlet ft. If tile field or leaching trenches ,total length is li65 ft. Width of trenches 212''ft.,depth of broken stone or screened gravel log ft. LOT #15 MARK ROAD C3� 1) ; oo. 0 - �I N� N t0 -3 ofj Cn n �o I I 0 j i N Ll I j ' I WMK ROAD FORMERLY ELM ROAD �k 11 FLOT PLAN MEDALLION HOMES, INv. SOUTH WINDsoP, .SAP REFEPENCEs GRAHAM ESTATES SECT 1nN i PROPERTY OFMURRAY HOeaES, INC. HAYtsa NEVERS ROADS, SOUTH WINDSOR,CONN. SCALE 1a=401 JULY 1956 MORTOt, s. FINE,C.E. REVosED 7-7.56. i %sF, .flf E�Fc'. I HEREBY CERTIFY G - j?�oc�Q.tid VS�'�� o THIS PLAN TO BE ' ENGINEERING AND LAND SURVEYING SUBSTANTIALLY 9 w" CORRECT; 740 NO. MAIN STREET, CROSSROADS PLAZA No 5547 WEST HARTFORD 7, CONNECTICUT •_' QfGISTri 4N0su DATE R L VIS.CD -t4l I'I = 40� 6-10-�3 6335;