Loading...
HomeMy WebLinkAbout949 AVERY STREET_2Civil Engineer°/Landscape Architect LRC Group 160 West Street, Suite E Cromwell, CT. 06416 860.635.2877 N N O N L 0 wo E Z �F+ .^^O a_ z^ n TOWN OF SOUTH WINDSOR PHILIP R. SMITH ELEMENTARY, SCHOOL 949 AVERY STREET SOUTH WINDSOR, CT 06074 STATE PROJECT NUMBER: 132=0089 N PHASE 2 OF 5 PHASE 1: ABATEMENT AND DEMOLgTION PHASE 2: SITE &BUILDING CONSTRUCTION PHASE 3 TECHNOLOGY (NETWORK EQUIPMENT ONLY) PHASE 4: FIXTURES, FURNISHINGS, EQUIPMENT (FF&E) &DATA /TECHNOLOGY EQUIPMENT PHASE 5: PLAYGROUND EQUIPMENT &SURFACING Construction Manager GILBANE Building Company 208A New London Turnpike Glastonbury, CT. 06033 860.368.5100 Structural Engineer GH-Til and COMPANY, LLP 10 Waterchase Drive Rocky Hill, CT. . 06067 860.563.3820 VOLUME 2 OF 2 Architect MOSER PILON NELSON Architects, LLC ®tre�ri�,�,��� Ii'4E1P1FP Engineers 30 Jordan Lane Wethersfield, CT. 06109 RZ DESIGN Associates, Inc® 750 Old Main Street, Suite 202 Rocky Hill, CT. 06067 860.436.4336 Owner's Representative COLLIERS International 135 New Road Madison, CT. 06443 860.563.6164 >G�TIONS 01ST 860.395.0055 U® r O ur JOSEPH J NORTON o CC REG. No, 202538R �z Techn� ��ES 3,-20 t nt iGNATU GUILLEN TechnologyR onsultan s, LLC 9 Moody Road, Building D, Suite 18 Enfield, CT. 06082 860.341.1206 Food Service Consultant RJS+Associates, LLC 4 High Street Old Lyme, CT. 06371 860.434.2700 Cost Estimator TARBELL CONSTRUCTION MANAGEMENT, Inc® 8 Spalding Road Stoneham, MA. 02180 781.435.0032 1 1 /2/LO 1 V CONFORM FnD S ET MARCH 229 2019 VOLUME I LIST OF DRAWINGS VOLUME 2 REVISIONS CONFORMED SET MARCH 22, 2019 G€IV€RAL 1.0 COVER VOLUME 1 1.1 LIST OF DRAWINGS 1.2 ABBREVIATIONS, DOOR CLEARANCES AND MOUNTING HEIGHTS CD1.1 CODE PLANS CD1.2 CODE INFORMATION CD2.1 OVERALL ACCESSIBLE ROUTE SITE PLAN CD2.2 ACCESSIBLE ROUTE SITE PLAN ENLARGEMENT CD2.3 ACCESSIBLE ROUTE SITE PLAN ENLARGEMENT SURVEY V-1 PROPERTY & TOPOGRAPHIC SURVEY CIVIL C1.0 OVERALL SITE DEMOLITION PLAN C1.1 SITE DEMOLITION ENLARGEMENT SOUTH C1.2 SITE DEMOLITION ENLARGEMENT NORTH C2.0 OVERALL SITE PLAN C2.1 SITE PLAN ENLARGEMENT SOUTH \ni2.4 SITE 1 E PLAN CIVLARGEIVIEIV 1 IVOR 1 H C2.3 SITE PLAN ENLARGEMENTS C2.4 FIRE LANE STRIPING & SIGNAGE PLAN C3.0 OVERALL GRADING & UTILITIES PLAN C3.1 GRADING & UTILITIES PLAN ENLARGEMENT SOUTH C3.2 GRADING & UTILITIES PLAN ENLARGEMENT NORTH C4.0 OVERALL SEDIMENTATION & EROSION CONTROL PLAN C4.1 SEDIMENTATION & EROSION CONTROL ENLARGEMENT SOUTH C4.2 SEDIMENTATION & EROSION CONTROL PLAN ENLARGEMENT C5.1 SITE DETAILS C5.2 SITE DETAILS C5.3 SITE UTILITY DETAILS C:5.44 SEDIMENTATION / EROSION CONTROL & PLANTING DETAILS AILS C5.5 SEDIMENTATION / EROSION CONTROL DETAILS C5.6 ADS STORMTECH DETAILS C5.7 SITE DETAILS C5.8 SITE DETAILS LANDSCAPE L1.0 OVERALL PLANTING PLAN L1.1 LANDSCAPE PLAN ENLARGMENT SOUTH L1.2 LANDSCAPE PLAN ENLARGEMENT NORTH L2.0 OVERALL SITE LIGHTING PLAN L2.1 SITE LIGHTING PLAN ENLARGEMENT SOUTH L2.2 SITE LIGHTING PLAN ENLARGEMENT NORTH A 01`LI ITC(`T1 10 A I mrlV1 II Lll I URML AO.0 AERIAL VIEWS AO.1 EXTERIOR VIEWS AO.2 EXTERIOR ENVELOPE ASSEMBLIES AO.3 INTERIOR ASSEMBLIES AO.4 EXTERIOR WALL MOCK-UP A1.0A OVERALL FIRST FLOOR PLAN A1.0B OVERALL SECOND FLOOR PLAN A1.0C OVERALL ROOF PLAN A1.1 PARTIAL FIRST FLOOR CONSTRUCTION PLAN - NORTH AND SOUTH A1.2 PARTIAL FIRST FLOOR CONSTRUCTION PLAN - WEST A1.3 PARTIAL SECOND FLOOR AND LOWER ROOF CONSTRUCTION PLAN - NORTH AND SOUTH A1.4 PARTIAL LOWER ROOF CONSTRUCTION PLAN - WEST A1.5 PARTIAL UPPER ROOF CONSTRUCTION PLANS A1.6 ALTERNATE 1 - ADDED CLASSROOMS PLANS AND CEILING PLAN A1.7 ALTERNATE 1 - ADDED CLASSROOMS ELEVATIONS A1.8 ALTERNATE 1 - ADDED CLASSROOMS FINISH PLANS AND SCHEDULES A2.0 OVERALL EXTERIOR ELEVATIONS A2,1 EXTERIOR ELEVATIONS A2.2 EXTERIOR ELEVATIONS A2.3 EXTERIOR ELEVATIONS A3.1 BUILDING SECTIONS A3.2 BUILDING SECTIONS A4.1 WALL SECTIONS A4.2 WALL SECTIONS A4.3 WALL SECTIONS A4.4 WALL SECTIONS A4.5 WALL SECTIONS A4.6 WALL SECTIONS A4.7 WALL SECTIONS A4.8 WALL SECTIONS A4.9 WALL SECTIONS A4.10 WALL SECTIONS A5.0 TYPICAL FLASHING DETAILS A5.1 TYPICAL FLASHING DETAILS A5.2 EXTERIOR DETAILS A5.3 EXTERIOR DETAILS A5.4 EXTERIOR DETAILS A5.5 EXTERIOR DETAILS A5.6 EXTERIOR DETAILS A5.7 EXTERIOR DETAILS A5.8 ROOF DETAILS A5.9 ROOF DETAILS A5.10 CAST STONE DETAILS A6.1 DOOR SCHEDULE AND TYPES A6.2 FRAME TYPES A6.3 FRAME TYPES A6.4 FRAME DETAILS A6.5 FRAME DETAILS A6.6 FRAME DETAILS A7.1 STAIR PLANS AND SECTIONS A7.2 STAIR AND RAMP PLANS AND SECTIONS A7.3 RAMP PLANS AND SECTIONS A7.4 STAIR, RAMP, AND GUARDRAIL DETAILS A7.5 ELEVATOR PLANS, SECTIONS AND DETAILS A8.0 TYPICAL CLASSROOM A8.1 ENLARGED PLANS AND ELEVATIONS - TOILET ROOMS A8.2 ENLARGED PLANS AND ELEVATIONS - TOILET ROOMS A8.3 ENLARGED GYMNASIUM AND PLATFORM PLAN A8.4 GYMNASIUM ELEVATIONS A8.5 INTERIOR ELEVATIONS A8.6 INTERIOR ELEVATIONS A8.7 INTERIOR ELEVATIONS A8.8 INTERIOR ELEVATIONS A8.9 INTERIOR ELEVATIONS A8.10 INTERIOR ELEVATIONS A8.11 INTERIOR ELEVATIONS A8.12 INTERIOR ELEVATIONS A8.13 INTERIOR ELEVATIONS A9.1 INTERIOR DETAILS A9.2 INTERIOR DETAILS A9.3 INTERIOR DETAILS A9.4 INTERIOR DETAILS A10.1 MILLWORK DETAILS A i n n M 1 V.G A, 0.3 Al 0.4 A11.0 A11.1 A11.2 A11.3 A11.4 A11.5 AF1.0 AF1.1 AF1.2 AF1.3 AF2.1 A F2.2 AF2.3 STRUCTURAL SO.1 SO.2 S 1.0 S1.1 S 1.2 S1.3 S2.0 S2.1 S2.2 S2.3 S2.4 S2.5 S2.6 S2.7 S3.0 JJ. I S3.2 S3.3 S3.4 S3.5 S3.6 S3.7 S4.OA S4.OB S4.1 S4.2 S4.3 S4.4 S4.5 S4.6 S4.7 S4.8 S4.9 S4.10 S4. i i S4.12 S4.13 S5.0 S5.1 S5.2 S5.3 S5.4 S5.5 S6.0 S6.1 S6.2 S6.3 S6.4 n All 11A//1171! f1CTAl1 C IVIILLVV l./RK UC I MILD MILLWORK DETAILS MILLWORK DETAILS OVERALL CEILING PLANS PARTIAL FIRST FLOOR CEILING PLANS - NORTH AND SOUTH PARTIAL FIRST FLOOR CEILING PLAN - WEST PARTIAL SECOND FLOOR CEILING PLAN CEILING DETAILS SIGNAGE AND SIGNAGE SCHEDULE INTERIOR FINISH SCHEDULE PARTIAL FIRST FLOOR FINISH PLANS NORTH AND SOUTH PARTIAL FIRST FLOOR FINISH PLAN WEST SECOND FLOOR FINISH PLAN PARTIAL FIRST FLOOR FURNITURE PLAN - NORTH AND SOUTH (FOR REFERENCE ONLY) PARTIAL FIRST FLOOR FURNITURE PLAN - WEST (FOR REFERENCE ONLY) SECOND FLOOR FURNITURE (FOR REFERENCE ONLY) STRUCTURAL DESIGN DATA OVERALL THREE 'D' VIEWS THREE'D' FOUNDATION VIEWS OVERALL FOUNDATION PLAN PARTIAL FOUNDATION PLAN - NORTH AND SOUTH PARTIAL FOUNDATION PLAN - WEST THREE "D" FRAMING VIEWS OVERALL SECOND FLOOR AND ROOF FRAMING PLANS PARTIAL SECOND FLOOR AND LOW ROOF FRAMING PLAN - NORTH AND SOUTH PARTIAL SECOND FLOOR AND LOW ROOF FRAMING PLAN - WEST PARTIAL HIGH ROOF FRAMING PLAN - NORTH AND SOUTH PARTIAL ROOF FRAMING PLAN - WEST FRAMING PLAN DETAILS ALTERNATE 1 - FRAMING PLANS TYPICAL CONCRETE DETAILS FOUNDATION SECTIONS FOUNDATION SECTIONS FOUNDATION SECTIONS FOUNDATION SECTIONS FOUNDATION SECTIONS FOUNDATION SECTIONS FOUNDATION SECTIONS TYPICAL FRAMING DETAILS TYPICAL DRAMING DETAILS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FnMIvj IVG SECTIONS FRAMING SECTIONS ALTERNATE NO. 1-FRAMING SECTIONS ROOF LOADING INFORMATION COLUMN SCHEDULE COLUMN SCHEDULE COLUMN BASE PLAN DETAILS COLUMN BASE PLAN DETAILS COLUMN BASE PLAN DETAILS LATERAL FRAME DETAILS LATERAL FRAME ELEVATIONS LATERAL FRAME ELEVATIONS ROOF TRUSS ELEVATIONS AND DETAILS ALTERNATE NO. 1 - COLUMN SCHEDULE AND LATERAL FRAME ELEATIONS GENERAL 2.0 COVER VOLUME 2 2.1 LIST OF DRAWINGS FOOD SERVICE FS-G1 FOOD SERVICE EQUIPMENT GENERAL NOTES FS-El FOOD SERVICE EQUIPMENT ELECTRICAL NOTES FS-P1 FOOD SERVICE EQUIPMENT PLUMBING NOTES FS-M1 FOOD SERVICE EQUIPMENT MECHANICAL NOTES FS-1.1.1 FOOD SERVICE EQUIPMENT SCHEDULE FS-1.2.1 FOOD SERVICE EQUIPMENT PLAN & SCHEDULE FS-1.3.1 FOOD SERVICE EQUIPMENT ELECTRICAL ROUGH -IN PLAN & SCHEDULE FS-1.4.1 FOOD SERVICE EQUIPMENT PLUMBING ROUGH -IN PLAN & SCHEDULE FS-1.5.1 FOOD SERVICE EQUIPMENT LIFE SAFETY & SPECIAL CONDITIONS PLAN FS-1.6.1 FOOD SERVICE EQUIPMENT ELEVATIONS REFERENCE PLAN FS-1.6.2 FOOD SERVICE EQUIPMENT ELEVATIONS FS-1.7.1 FOOD SERVICE SLAB PENETRATIONS PLAN STATE PROJECT NO. FS-1.7.3 FOOD SERVICE EQUIPMENT EXHAUST CFM PLAN 132-0089 N FS- I.8. I FOOD SER VICE IZUUIPIVIE V I EXHAUS I HUOD UE I AILS PHASE 2 OF 5 FS-1.8.2 FOOD SERVICE EQUIPMENT EXHAUST HOOD DETAILS FS-1.8.3 FOOD SERVICE EQUIPMENT EXHAUST HOOD DETAILS FS-1.9.1 FOOD SERVICE EQUIPMENT WALK-IN DETAILS FS-1.9.2 FOOD SERVICE EQUIPMENT WALK-IN DETAILS FS-1.9.3 FOOD SERVICE EQUIPMENT WALK-IN DETAILS FS-1.13.1 FOOD SERVICES EQUIPMENT MANUFACTURERS DETAILS - MULTITERIA FS-1.13.2 FOOD SERVICES EQUIPMENT MANUFACTURERS DETAILS - MULTITERIA FIRE PROTECTION FP1.1 FIRE PROTECTION FIRST FLOOR PLAN NORTH AND SOUTH FP1.2 FIRE PROTECTION FIRST FLOOR PLAN WEST FP1.3 FIRE PRU I EC I ION SECONU FLUUH PLAN - NUR I H ANU 5UU 1 H f, a FP1.4 FP-2.1 FIRE PROTECTION ALTERNATE 1 - ADDED CLASSROOMS FIRE PROTECTION DETAILS \� PLUMBING PO.1 PLUMBING GENERAL NOTES, ABBREVIATIONS AND SYMBOLS PU1.1 PLUMBING UNDERSLAB PLAN NORTH AND SOUTH PU1.2 PLUMBING UNDERSALB PLAN - WEST P1.1 PLUMBING FIRST FLOOR PLAN NORTH AND SOUTH P1.2 PLUMBING FIRST FLOOR PLAN WEST {..G.r P1.3 PLUMBING SECOND FLOOR PLAN - NORTH AND SOUTH P1.4 PLUMBING ROOF PLAN �..i P1.5 ALTERNATE 1-ADDED CLASSROOMS P2.1 PLUMBING ENLARGED PLANS & DETAILS D4 i 1 V. 1 DI 1 IflADlnl(_ 1C(IhACT0I11C 1 LVIVIV11Nt_/ I I II\JJ / O P3.2 PLUMBING ISOMETRICS P4.1 PLUMBING DETAILS P4.2 PLUMBING DETAILS W W P5.1 PLUMBING SCHEDULES t-� MECHANICAL MO.0 M1.1 MECHANICAL LEGEND MECHANICAL DUCTWORK FIRST FLOOR PLAN - NORTH AND SOUTH H G� M1.2 MECHANICAL DUCTWORK FIRST FLOOR PLAN - WEST q 71 M1.3 MECHANICAL DUCTWORK SECOND FLOOR PLAN - NORTH AND SOUTH M1.4 MECHANICAL ROOF M1.5 ALTERNATE 1 ADDED CLASSROOMS T M2.1 M2.2 MECHANICAL PIPING FIRST FLOOR PLAN - NORTH AND SOUTH MECHANICAL PIPING FIRST FLOOR PLAN WEST - M2.3 MECHANICAL PIPING SECOND FLOOR PLAN - NORTH AND SOUTH M3.1 MECHANICAL RISER DIAGRAMS M4.1 MECHANICAL DETAILS M4.2 MECHANICAL DETAILS nAa i IVIO 1 nAC(-LIAAII(1AI C(LlC fli II CCU IVICVI-Il11V I\11ML Jl.ifICULJLLJ [• j r7///J//�yJA( M5.2 MECHANICAL SCHEDULES M6.1 MECHANICAL PARTIAL PLANS AND ISOMETRICS 0 ELECTRICAL R/J EO.0 ELECTRICAL LEGENDS E1.1 ELECTRICAL LIGHTING FIRST FLOOR PLAN - NORTH AND SOUTH E1.2 ELECTRICAL LIGHTING FIRST FLOOR PLAN - WEST E1.3 ELECTRICAL LIGHING SECOND FLOOR PLAN - NORTH AND SOUTH E2.1 ELECTRICAL POWER FIRST FLOOR PLAN - NORTH AND SOUTH E2.2 ELECTRICAL POWER FIRST FLOOR PLAN - WEST E2.3 ELECTRICAL POWER SECOND FLOOR PLAN - NORTH AND SOUTH E2.4 ELECTRICAL ROOF POWER PLAN E3.1 ELECTRICAL LOW VOLTAGE FIRST FLOOR PLAN - NORTH AND SOUTH F-3.2 ELECTRI('AL_ IOW VOLTAGE FIRST FLOOR PLAN - WFST E3.3 ELECTRICAL LOW VOLTAGE SECOND FLOOR PLAN - NORTH AND SOUTH E4.1 ALTERNATE 1 - ADDED CLASSROOMS E5.1 ELECTRICAL SCHEDULES E5.2 ELECTRICAL SCHEDULES E5.3 ELECTRICAL SCHEDULES E6.1 ELECTRICAL RISER DIAGRAM E6.2 ELECTRICAL RISER DIAGRAM E7.1 ELECTRICAL DETAILS E7.2 ELECTRICAL DETAILS E7.3 ELECTRICAL DETAILS i SE1.1 SITE ELECTRICAL PLAN TECHNOLOGY T000 GENERAL SHEET TECHNOLOGY TOOA GENERAL SHEET TECHNOLOGY T100B SOUND FIELD SYMBOLS AND RISER DIAGRAMS T101 OVERALL TECHNOLOGY FIRST FLOOR PLAN T101A PARTIAL FIRST FLOOR PLAN - NORTH AND SOUTH Ti nl R PARTAAI FIRST F1 OC)R PI AN - WFST (I T102 OVERALL TECHNOLOGY SECOND FLOOR PLAN T102A PARTIAL SECOND FLOOR CEILING PLANS - NORTH AND SOUTH T200 ENLARGED PLANS AND ALTERNATE #1 FLOOR PLAN T301 TELECOMUNICATION ENLARGED PLAN AND DETAILS 13UZ UE I AIL I ECHIVOLOG Y T303 DETAIL TECHNOLOGY T304 DETAIL TECHNOLOGY T401 LOCAL SOUND RISER DIAGRAM AND DETAILS FOR REFRENCE ONLY T501 P/A, CLOCK RISER DIAGRAM AND DETAILS T601 INTRUSION AND ACCESS CONTROL DETAILS �.�`¢ 00 Af,, T602 ELECTRONIC SAFETY AND SECURITY SURVEILANCE 9 ..........Cj►'�� ei7 "'ice o; js .? z: 1 0 ;A., t � MOSER ?ILON NELSON ARCHI,ECrs 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE LIST OF DRAWINGS DATE 11/2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 2.1 :Ei A. THESE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL SET OF CONSTRUCTION DOCUMENTS AS APPLICABLE. B. THE DRAWINGS AND SPECIFICATIONS, AND ALL COPIES THEREOF, ARE LEGAL INSTRUMENTS OF SERVICE FOR THE USE BY THE OWNER AND AUTHORIZED REPRESENTATIVES ON THE DESIGNATED PROPERTY ONLY. OTHER USE, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE OWNER, RJS ASSOCIATES, OR THE PROJECT ARCHITECT, IS PROHIBITED. C. SPECIFICATIONS, DETAILS AND SCHEDULES, WHICH MAY BE BOUND SEPARATELY AND REFERENCED BY PROJECT NAME, AKE PAK I OF T HESE CON I RACTI DUCUi 1EIv1S. DRAWINGS BY CONSULTING PROFESSIONALS, INCLUDING FOOD SERVICE CONSULTANTS, ARE SUPPLEMENTARY AND SUBORDINATE TO THE ARCHITECTURAL DRAWINGS AND ARE PART OF THESE CONTRACT DOCUMENTS AS MAY BE APPLICABLE. D. THE KITCHEN EQUIPMENT CONTRACTOR SHALL NOTIFY THE FOOD SERVICE CONSULTANT IMMEDIATELY OF ANY OMISSIONS OR DISCREPANCIES BETWEEN THE FOOD SERVICE DRAWINGS, ARCHITECTURAL DRAWINGS, CONSULTING PROFESSIONALS DRAWINGS, SPECIFICATIONS OR EXISTING CONDITIONS. SHOULD TUCDC DC: ANI nMTccrnnl nD McrDF'DANIry rzp-nA/PPNI CATII f1RAXA/TNIrq ANIn IIILIIL lJL 1"11Y VI'IdJJAV1Y VI\ V1Jt.\LI nitlt.l vLvtl LLitl .ii i.iv vv v v.i°w SPECIFICATIONS, IT SHALL BE BROUGHT TO THE FOOD SERVICE CONSULTANT'S ATTENTION IN WRITING FOR CLARIFICATION PRIOR TO BIDDING, EXECUTION OR INSTALLATION OF SAID WORK. E. ALL WORK SHALL CONFORM TO ALL RULES AND REGULATIONS OF FEDERAL, STATE AND LOCAL GOVERNMENT AGENCIES AND JURISDICTIONS HAVING AUTHORITY OF THE PROJECT, INCLUDING STATE AND FEDERAL ACCESSIBILITY REQUIREMENTS. F. THE KITCHEN EQUIPMENT CONTRACTOR SHALL NOTIFY THE FOOD SERVICE CONSULTANT IMMEDIATELY IF INFORMATION IS NOT SHOWN OR IS UNCLEAR. G. THE KITCHEN EQUIPMENT CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO STARTING WORK AND REPORT ANY DISCREPANCIES IN WRITING TO THE FOOD SERVICE CONSULTANT. ANY WORK INSTALLED IN CONFLICT WITH THE FOOD SERVICE DRAWINGS SHALL BE CORRECTED AT THE KITCHEN EQUIPMENT CONTRACTOR'S EXPENSE. H. THE KITCHEN EQUIPMENT CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FOR ALL WORK. I. THE KITCHEN EQUIPMENT CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SCHEDULING AND COORDINATING THE WORK FOR ALL UTILITIES AND SERVICES RELATED TO THIS WORK. J. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO BE CONSTRUCTION STANDARDS. QUESTIONS REGARDING THE SAME, OR THEIR EXACT MEANING, SHALL BE DIRECTED TO THE FOOD SERVICE CONSULTANT. K. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. DO NOT SCALE DRAWINGS. THE KITCHEN EQUIPMENT CONTRACTOR SHALL, AT THE MINIMUM, BE RESPONSIBLE FOR THE ACCURATE PLACEMENT AND CONFIGURATION OF THE EQUIPMENT WITHIN ITS SCOPE ON THF= STTE L. ALL EXTERIOR WALL DIMENSIONS ARE TO FACE OF STUD, CONCRETE OR MASONRY, UNLESS OTHERWISE NOTED. M. ALL INTERIOR WALL DIMENSIONS ARE TO FACE OF METAL STUD, OR TO FACE OF MASONRY OR CONCRETE, UNLESS OTHERWISE NOTED. N. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB, UNLESS OTHERWISE NOTED. 0. FLOOR TO CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES, UNLESS OTHERWISE NOTED. P. ALL DOOR SIZES SHOWN ON SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR THRESHOLDS, ETC. SHALL BE DEDUCTED. FRAMES SHALL BE REINFORCED WHERE REQUIRED, FOR CLOSERS, STOPS AND HARDWARE. Q. THE KITCHEN EQUIPMENT CONTRACTOR SHALL VERIFY LOCATION OF ALL STIFFENERS, BRACES, BLOCKING, BACKING, HANGERS, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF THE CASEWORK, FIXTURES AND ALL WALL -MOUNTED OR SUSPENDED KITCHEN EQUIPMENT, OR MISCELLANEOUS EQUIPMENT OR FURNISHINGS THAT ARE CONTAINED IN THIS WORK. R. THE KITCHEN EQUIPMENT CONTRACTOR SHALL VERIFY EXACT SIZES AND LOCATIONS OF ALL ITEMS WITHIN HIS SCOPE, INCLUDING, BUT NOT LIMITED TO; EQUIPMENT CURBS, BASE STRUCTURES, AS WELL AS POWER, WATER, DRAIN, GAS INSTALLATIONS AND LOCATIONS. ALL ITEMS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURERS BEFORE PROCEEDING WITH THE WORK. CHANGES TO ACCOMMODATE THE FIELD CONDITIONS OR APPROVED ALTERNATES SHALL BE MADE WITHOUT ADDITIONAL CHARGE TO THE OWNER OR RJS ASSOCIATES. S. ALL PIPES, CONDUITS, WIRES AND DUCTS SHALL BE CONCEALED FROM VIEW UNLESS OTHERWISE NOTED. A. HIDDEN CONDITIONS: THE KITCHEN EQUIPMENT CONTRACTOR IS TO CONTACT THE FOOD SERVICE CONSULTANT IMMEDIATELY UPON UNCOVERING ANY HIDDEN CONDITION. THE FOOD SERVICE CONSULTANT IS TO PROVIDE DIRECTION. T. CLEAN UP: DAILY REMOVAL OF CONSTRUCTION DEBRIS RELATED TO THIS WORK. _ f 5 a 3e , Y a 7 ' PROJECT SPECIFICATIONS FORM A PART OF THESE GENERAL NOTES. A. THESE DRAWINGS TO BE USED IN CONJUNCTION WITH THE FULL SET OF CONSTRUCTION DOCUMENTS AS APPLICABLE. B. THE KITCHEN EQUIPMENT CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION OF CUSTOM FABRICATED KITCHEN EQUIPMENT. THE ARCHITECT AND RJS ASSOCIATES SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. C. DO NOT SCALE THE DRAWINGS. D. NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES AND THE TYPICAL DETAILS. E. ALL SPECIFICATIONS AND CODES NOTED SHALL BE THE LATEST APPROVED EDITIONS AND REVISIONS OF THE GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER THIS PROJECT. F. SEE THE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING: SIZE AND LOCATION OF WINDOW AND DOOR OPENINGS. SIZES AND LOCATIONS OF INTERIOR AND EX I ERIUR IVUNBEAKIIvG PAR I I I IONS. SIZES AND LOCATIONS OF CONCRETE CURBS, CONVENIENCE FLOOR DRAINS, SLOPES, DEPRESSED AREAS, CHANGES IN LEVELS, CHAMFERS, GROOVES, INSERTS, ETC. SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS. FLOOR AND ROOF FINISHES. STAIR FRAMING AND DETAILS. DIMENSIONS NOT SHOWN ON THE FOOD SERVICE DRAWINGS. CEILING ASSEMBLIES AND HEIGHTS. EXTERIOR WALL ASSEMBLIES. G. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR THE FOLLOWING: PIPES, SLEEVES, HANGERS, TRENCHES, WALL, FLOOR AND ROOF OPENINGS, DUCT PENETRATIONS, ETC. EXCEPT AS SHOWN OR NOTED. CONVENIENCE FLOOR SINKS. ELECTRICAL CONDUIT RUNS, BOXES, OUTLE I-S IN WALLS AND SLABS. CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL, OR PLUMBING FIXTURES. SIZE AND LOCATION OF MACHINE OR EQUIPMENT BASES, ANCHOR BOLTS FOR MOUNTS. BEVERAGE CONDUIT RUNS AND PULL BOXES, UNLESS INCLUDED IN RJS FOOD SERVICE DRAWINGS. H. SEE INTERIOR DESIGN DRAWINGS FOR THE FOLLOWING: CEILING PATTERNS, MATERIALS, FINISHES, DECORATIVE LIGHT FIXTURES, LOCATIONS AND ADDITIONAL CEILING INFORMATION. DIMENSIONS AND ALL INTERIOR WALL ELEVATIONS. DETAILS OF BOOTHS, BAR, COUNTER AND BUILT-INS. I. SEE RJS ASSOCIATES FOOD SERVICE SPECIAL CONDITIONS DRAWINGS FOR WALL BACKING INFORMATION, SLAB DEPRESSIONS, BEVERAGE CONDUIT ROUTING, BULK CO2 FILL BOX, ETC. J. SEE ELECTRICAL RJS ASSOCIATES FOOD SERVICE DRAWINGS FOR WALL MOUNTED EQUIPMENT OUTLETS, SWITCHES AND DETAILS. K. SEE PLUMBING RJS ASSOCIATES FOOD SERVICE DRAWINGS FOR INFORMATION ON FLOOR SINKS, FLOOR DRAINS AND NEW EQUIPMENT LAYOUT AT KITCHEN, SCULLERIES AND SERVICE STATIONS. L. THE CONTRACT RJS ASSOCIATES FOOD SERVICE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED DESIGN. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. M. THE KITCHEN EQUIPMENT CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE FOOD SERVICE EQUIPMENT, WORKING AND ADJACENT SPACES DURING CONSTRUCTION. N. NOTIFY RJS ASSOCIATES FOOD SERVICE CONSULTANT WHEN DRAWINGS BY OTHER DESIGN TEAM MEMBERS SHOW OPENINGS, POCKETS, WALLS, ETC. 0. KITCHEN EQUIPMENT CONTRACTOR SHALL INVESTIGATE THE SITE DURING ALL PHASES OF CONSTRUCTION. IF ANY BURIED STRUCTURES, CESSPOOLS, CISTERNS, FOUNDATIONS, UTILITIES, ETC. ARE FOUND, RJS ASSOCIATES SHALL BE NOTIFIED IMMEDIATELY. P. REFER TO PROJECT SPECIFICATIONS FOR SPECIFIC SUBMITTAL PROCEDURES. Q. IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND/OR THE GENERAL CONTRACTOR TO INSURE THAT ALL OF THE CONSULTANTS AND SUB -CONTRACTORS RECEIVE COPIES OF ANY AND ALL ADDENDUMS OR CHANGES TO THE CONSTRUCTION DOCUMENTS OR FIELD CONDITIONS WHICH ARE MADE PRIOR TO AND DURING CONSTRUCTION. R. KITCHEN EQUIPMENT CONTRACTOR SHALL BE RESPONSIBLE FOR ALL GENERAL CLEAN-UP AND DISPOSAL OF ALL TRASH, CARTONS, CRATES, DEBRIS, ETC. AFTER FINAL INSTALLATION OF ALL FIXTURES AND EQUIPMENT, UNLESS OTHERWISE NOTED, INCLUDING FINAL NON -SANITARY CLEANING. S. ALL BASE CONSTRUCTION, MECHANICAL, PLUMBING, ELECTRICAL, WIRING AND CONDUIT REQUIREMENTS RELATED TO EQUIPMENT AS INDICATED ON RJS ASSOCIATES CONSTRUCTION DOCUMENTS ARE TO BE COMPLETED BY THE GENERAL CONTRACTOR AND/OR SUB -CONTRACTORS. (CONTINUED) T. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL HAVE INCLUDED IN HIS SCOPE, ALL WORK NECESSARY TO PROPERLY COORDINATE AND FACILITATE THE INSTALLATION OF ALL FOOD SERVICE EQUIPMENT BY THE KITCHEN EQUIPMENT CONTRACTOR, INCLUDING THE INSTALLATION OF ALL RELATED ITEMS REQUIRED. THIS WORK SHALL INCLUDE ALL NECESSARY CORE DRILLING AND SLEEVES THROUGH WALLS, CEILINGS, FLOORS, COLUMNS AND BEAMS FOR THE PASSAGE OF ALL UTILITIES AND REFRIGERATION LINES. THIS WORK SHALL ALSO INCLUDE ALL EMPTY CONDUITS, ALL EQUIPMENT PADS/CURBS, ALL PLUMBING AND ELECTRICAL REQUIREMENTS AS DESCRIBED ON RJS ASSOCIATES FOOD SERVICE CONSTRUCTION DOCUMENTS, ALL DUCT SHAFTS AND WALL BACKING. U. THE LAST DATED REVISION VOIDS ALL PREVIOUS FOOD SERVICE CONSTRUCTION DOCUMENTS CONTAINED IN THIS SET. V. GENERAL CONTRACTOR SHALL NOTIFY AND COORDINATE WITH ALL SUPPLIERS AND/OR SUB -CONTRACTORS UPON COMPLETION OF ANY APPLICABLE ROUGH -IN OR OTHER WORK IN ORDER TO FACILITATE THE VERIFICATION OF ALL ROUGH -IN LOCATIONS AND/OR EQUIPMENT DIMENSIONS AS REQUIRED. DESIGN DRAWINGS A. DESIGN DRAWINGS ARE DIAGRAMMATIC AND ARE ONLY INTENDED TO DEFINE THE BASIC FUNCTIONS REQUIRED. PROVIDE ALL WORK, MATERIAL, ETC. NECESSARY TO ACCOMPLISH THESE REQUIREMENTS. MINOR DEVIATIONS FROM THE DESIGN LAYOUT ARE ANTICIPATED AND ARE PART OF THE WORK INCLUDED: HOWEVER, NO CHANGES THAT ALTER THE DESIGN INTENT OR FUNCTION OF THE WORK WILL BE PERI iITiED. DO IdOT SCALE THE v°;v"viI"IvS. B. IF A CONFLICT OCCURS BETWEEN THE DESIGN DRAWINGS AND SPECIFICATIONS, THE MOST STRINGENT SHALL APPLY. y . f° a r .. a (E) EXSITING (X) EXISTING TO BE REMOVED (R) RELOCATE NIC NOT IN CONTRACT U.O.N. UNLESS OTHERWISE NOTED FBO FURNISHED BY GC FF & E FIXTURES FURNISHINGS AND EQUIPMENT AFF ABOVE FINISHED FLOOR S/STL STAINLESS STEEL R"'EFERENCE SlYMBU"LS THE FOLLOWING SYMBOLS MAYBE USED IN THE DRAWINGS: 1 A COLUMN REFERENCES Aeol DOOR REFERENCE ROOM NUMBER go, WINDOW REFERENCE OLOUVER RE.FERENCE W_2 WALL TYPE REFERENCE FLASHING REFERENCE KEYNOTE REFERENCE KITCHEN/LAUNDRY EQUIPMENT REFERENCE EXISTING WALLS TO REMAIN NEW GYPSUM BOARD STUD WALL Q ADDENDUM / BULLETIN NO. REVISION REFERENCE MATCH LINE _ SHADED SIDE IS SIDE CONSIDERED WORK POINT/CONTROL POINT OR DATUM ¢7'-0" ELEVATION REFERENCE A.F.F. A SECTION REFERENCE A4.1 SECTION IDENTIFICATION SHEET'WHERE SECTION IS DRAWN SECTION CUT DIRECTION A DETAIL REFERENCE A4.1 DETAIL IDENTIFICATION SHEET WHERE DETAIL IS DRAWN AL 0 7 � B INTERIOR ELEVATION REFERENCE INTERIOR ELEVATION DIRECTION INTERIOR ELEVATION NUMBER C SHEET'WHERE ELEVATION IS DRAWN 2 EXTERIOR ELEVATION REFERENCE D92 ELEVATION NUMBER SHEET WHERE ELEVATION IS DRAWN ROOM sloe ROOM IDENTIFICATION ROOM NAME ROOM NUMBER NORTH ARROW REVISIONS CONFORMED SET MARCH 22, 2019 A 2-19-2019 BID SUPPLEMENT 1 0 2-22-2019 BID SUPPLENIENT 2 STATE PROJECT NO. 132-0089 N Phase 2 of 5 O O O E"d o W N O �w� � o • V i i I i �.A:oagpG8G99CPy�y,1 � "Cl 0 AR RIS + ASSOCIATES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434.3735 �mv.Osfsdxom H'iL I� P1�� II SON ARC H I T E C T S 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT GENERAL NOTES DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. REVISIONS CONFORMED SET MARCH 22, 2019 2-19-2019 BID SUPPLEMENT I 2-22-2019 BID SUPPLEMENT 2 ELECTRICAL ,gREQUIREMENT"o GENERAL NOTES: A. ALL WORK INDICATED ON THE ELECTRICAL ROUGH -IN PLAN MUST BE COMPLETED BY OTHER THAN THE KITCHEN EQUIPMENT CONTRACTOR AND MUST COMPLY WITH ALL LOCAL CODES AND REGULATIONS. B. A CATALOG OF MANUFACTURERS EQUIPMENT SPECIFICATION SHEETS IS INCLUDED AS AN INTEGRAL PORTION OF THIS SUBMITTAL, WE SUGGEST THEREFORE THAT ALL TRADES REVIEW THE REQUIREMENTS AS INDICATED REGARDING EACH MANUFACTURER. C. CROSS REFERENCE ALL INFORMATION PER ROUGH -IN DRAWINGS WITH EQUIPMENT SCHEDULE DRAWINGS. D. THE ELECTRICAL ROUGH -IN PLAN IS PROVIDED FOR INFORMATION ONLY, IS BASED ON A 60 HERTZ, UNLESS OTHERWISE NOTED. ELECTRICAL SYSTEM AND IS INTENDED TO SHOW FOOD SERVICE FIXTURES AND EQUIPMENT OUTLET TYPES, LOCATIONS, LOADS AND CONNECTION POSITIONS ONLY. FURNISH ANY ADDITIONAL OUTLETS AS REQUIRED BY LOCAL CODES OR REQUESTED BY OWNER. REFER TO ARCHITECTURAL OR ELECTRICAL ENGINEERING PLANS FOR ANY ADDITIONAL ELECTRICAL REQUIREMENTS. E. REFER TO APPROVED SHOP DRAWINGS FOR SUPPLEMENT AL ELECTRICAL CONNECTIONS AND INSTALLATION REQUIREMENTS FOR THE FOOD SERVICE EQUIPMENT INDICATED ON THIS PLAN. F. ELECTI RICAL REQUIREI"IEINIT S FVR CXIJ I IIVG AIVU VVVIVER OR PURVEYOR PROVIDED EQUIPMENT MUST BE VERIFIED WITH THE ACTUAL EQUIPMENT SUPPLIED. THESE PLANS ARE MINIMUM GUIDELINES ONLY AND MUST BE VERIFIED. CONTACT OWNER OR EQUIPMENT PROVIDER FOR LOCATION OR SPECIFICATIONS FOR THIS EQUIPMENT. G. EXPOSED ELECTRICAL SERVICES STUBBED UP OUT OF THE FLOOR MUST BE PROTECTED AND INSTALLED IN A MANNER WHICH WILL PREVENT DAMAGE FROM WATER OR IF HIT BY PORTABLE KITCHEN EQUIPMENT, HEAVILY LOADED CARTS OR FLOOR CLEANING EQUIPMENT. H. PRIOR TO THE INSTALLATION OF THE FOOD SERVICE EQUIPMENT, THE ELECTRICAL CONTRACTOR MUST CONFIRM THAT ELECTRICAL WIRING HAS BEEN PULLED THROUGH JUNCTION BOXES. ELECTRICAL CONTRACTORS NOTES: ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND FOR INSTALLING OF THE FOLLOWING, AND FOR MAKING ALL FINAL CONNECTIONS TO FOOD SERVICE EQUIPMENT AS SHOWN ON THIS PLAN UNLESS OTHERWISE NOTED. A. ELECTRICAL CONTRACTORS SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE ALL FINAL CONNECTIONS AND SHALL INCLUDE ALL ITEMS REQUIRED BY APPLICABLE LAWS. B. ELECTRICAL CONTRACTORS TO CROSS REFERENCE ROUGH -IN DRAWINGS, STAINLESS STEEL FABRICATION, WALK-IN DRAWINGS, EXHAUST HOOD DRAWINGS AND MILLWORK DETAIL DRAWINGS. C. ALL WIRING, WIRING CONDUITS, JUNCTION BOXES, ELECTRICAL OUTLETS, SWITCHES, COVER PLATES, PLUG MOLDING, ETC. AS SHOWN ON PLAN AND NOT PROVIDED BY OTHERS. RUN ALL OF THE ELECTRICAL SERVICE LINES IN WALLS OR CONCEALED WHEREVER POSSIBLE. ALL EXPOSED SERVICES, COMPONENTS AND CONNECTIONS TO BE VAPOR TIGHT. D. ALL DISCONNECTS OR OTHER DEVICES AS REQUIRED BY LOCAL CODES. DO NOT LOCATE DISCONNECTS OR OTHER DEVICES (OTHER THAN JUNCTION BOX CONNECTIONS OR CORD AND PLUG RECEPTACLES) BEHIND COOKING EQUIPMENT OR BELOW EXHAUST HOOD ASSEMBLIES. E. ALL SHUNT -TRIP CIRCUIT BREAKERS OR DISCONNECTS FOR FIRE SUPPRESSION SYSTEM SHUT-OFF OF ALL ELECTRICAL BELOW AND IN EXHAUST HOODS AND VENTILATORS, INTERWIRED WITH FIRE SUPPRESSION SYSTEM, AS REQUIRED BY N.F.P.A. STANDARDS AND ANY LOCAL CODES AND REGULATIONS. F. ALL RECEPTACLES, OUTLETS AND CORD AND PLUG ASSEMBLIES TO BE NEMA SIZED, UL APPROVED AND RATED FOR THE SERVICE INDICATED ON THESE PLANS. G. WALK-IN COOLER/FREEZER LOCATIONS SHOWN IN THIS PLAN: 1) ALL VAPOR PROOF LIGHT FIXTURES, AS REQUIRED BY KITCHEN EQUIPMENT CONTRACTOR. 2) ALL DISCONNECTS AND SWITCHES AT BLOWER COILS BY ELECTRICAL CONTRACTOR. 3) ALL VAPOR PROOF DUPLEX CONVENIENCE OUTLETS AS INDICATED BY ELECTRICAL CONTRACTOR. 4) ALL INTERCONNECTIONS FOR ELECTRICAL COMPONENTS IN THE COOLER/FREEZER COMPARTMENTS BY ELECTRICAL CONTRACTOR, INCLUDING CONTROL WIRING BETWEEN WALK-IN FREEZER COIL AND REMOTE CONDENSER TO ACCOMMODATE DEFROST CYCLE TIMER. 5) ALL INTERCONNECTIONS FOR FREEZER EVAPORATORS AND COMPRESSORS, INCLUDING HEAT TAPE, VERIFY EXACT WIRE SIZES WITH MANUFACTURERS SPECIFICATIONS, BY ELECTRICAL CONTRACTOR. H. ALL WIRING CONDUITS INTO WALK-IN COOLER/FREEZER COMPARTMENTS FOR THE FOLLOWING BY ELECTRICAL CONTRACTOR: 1) EACH EVAPORATOR COIL. 2) EACH VAPOR PROOF CEILING LIGHT. 3) EACH PERSONNEL ALARM SWITCH AND LIGHT. 4) EACH HIGH TEMPERATURE WARNING ALARM SYSTEM. m E z U z w . pyry.. 1 (continued) I. ALL PENETRATIONS FOR THE REQUIRED SERVICES MUST BE MADE THROUGH THE CEILING INSULATION AND ARE REQUIRED TO BE VAPOR TIGHT. ALL CONDUITS TO RUN ABOVE THE WALK-IN COMPARTMENTS. J. ALL COMPRESSOR LOADS SHALL BE SIZED FOR APPROXIMATELY 3500 WA 1 I-S PER HORSEPOWER, OR PER NATIONAL ELECTRICAL CODE. VERIFY REQUIREMENTS WITH MANUFACTURERS NAME PLATE DATA. K. ALL WIRING TO AND INTERWIRING BETWEEN THE FOLLOWING: 1) EXHAUST HOOD/VENTILATOR COMPARTMENTS. 2) ELECTRICIAN TO SIZE AND SUPPLY STARTER MOTORS FOR EXHAUST HOOD FANS. 3) ELECTRICAL SERVICES TO CONTROL PANELS. EXACT REQUIREMENTS FOR THE NUMBER OF WIRES AND ELECTRICAL SERVICE MUST BE VERIFIED WITH THE APPROVED SHOP DRAWINGS AND COMPLY WITH LOCAL CODES AND REGULATIONS BY ELECTRICAL CONTRATOR. 4) CONTROL WIRING FROM CONTROL PANEL TO EACH HOOD SECTION FOR DAMPERS, SOLENOIDS AND LIGHTS BY ELECTRICAL CONTRATOR. 5) CONTROL WIRING FROM CONTROL PANEL TO EXHAUST AND SUPPLY FANS. THESE FANS SHALL BE ELECTRICALLY INTERLOCKED BY ELECTRICAL CONTRACTOR. 6) FIRE SYSTEMS CONTROL INTERWIRING BETWEEN FIRE SUPPRESSION SYSTEMS, CONTROL PANELS AND REMOTE SHUT -OFFS BY ELECTRICAL CONTRACTOR. 7) CONTROL WIRING FROM CONTROL PANEL TO EACH REMOTE DE'II ERGEIV T PUMP AS APPLICABLE BY ELECT RICAL C VI I I RAC T 0R. L. ALL REQUIRED MATERIALS TO MAKE FINAL CONNECTIONS TO ALL FOOD SERVICE EQUIPMENT SHOWN ON THIS PLAN BY ELECTRICAL CONTRACTOR. M. AVOID LOCATING ELECTRICAL PANELS BEHIND FOOD SERVICE EQUIPMENT. REFER TO EQUIPMENT PLANS FOR THE LOCATIONS OF EQUIPMENT THAT DOES NOT APPEAR ON THIS ELECTRICAL ROUGH -IN PLAN N. AN ISOLATED CIRCUIT WITH A CLEAN EARTH GROUND FOR ALL OWNER PROVIDED POINT -OF -SALE EQUIPMENT, CREDIT CARD SCANNERS AND VALIDATION MACHINES. VERIFY ELECTRICAL REQUIREMENTS WITH THE OWNER AND EQUIPMENT, BY ELECTRICAL CONTRACTOR. 0. INTERCONNECT WASTE PULPER CONTROL PANEL WITH THE PULPER, EXTRACTOR AND REMOTE STOP -START STATIONS, AS PER MANUFACTURERS SPECIFICATIONS, BY ELECTRICAL CONTRACTOR. ENE[-Nlr%L NOTES (THESE NOTES SUPPLEMENT THE MASTER SPECIFICATIONS AND ARE RELATED TO WORK SURROUNDING FOOD SERVICE.) A. DEFINITION: THE WORD "PROVIDE" MEANS: FURNISH, INSTALL FEED, CONNECT WITH ALL ACCESSORIES AND ANCILLARY EQUIPMENT FOR A COMPLETE OPERATING INSTALLATION BY THE APPROPRIATE TRADE, AS NOTED. B. CODES: WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. C. COMPLETE INSTALLATION: ELECTRICAL CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, ACCESSORIES, ETC. NECESSARY TO ACCOMPLISH A COMPLETE ELECTRICAL SYSTEM IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS PERFORMED BY APPLICABLE TRADES. D. GROUNDING: ELECTRICAL CONTRACTOR TO GROUND ALL EQUIPMENT AND SYSTEM NEUTRALS IN ACCORDANCE WITH THE CODE. PROVIDE CODE SIZE EQUIPMENT GROUNDING CONDUCTOR IN ALL FEEDERS AND BRANCH CIRCUIT RACEWAYS. WHERE ISOLATED GROUNDS ARE INDICATED, PROVIDE INSULATED CONDUCTOR. E. CIRCUITING: ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CIRCUITING IN CONDUIT. EMT WITH STEEL INSULATED THROAT SET -SCREW FITTINGS MAY BE USED IN DRY INTERIOR LOCATIONS. PVC WITH WRAPPED RIGID ELBOWS AND RISERS SHALL BE USED IN CONCRETE AND BELOW GRADE. RGS OR IMC CIRCUITING SHALL BE CONCEALED. WHERE CONCEALMENT IS IMPRACTICAL, AND WITH THE SPECIFIC APPROVAL OF THE ENGINEER, SURFACE RACEWAY AND OUTLETS MAY BE INSTALLED, FINISHED TO MATCH ADJACENT SURFACES. METAL -CLAD CABLE (TYPE MC) MAY BE USED PER THE FOLLOWING: 1) LIMITED SINGLE -CIRCUIT, DEAD-END FEEDS IN DRY LOCATIONS, WITHIN ACCESSIBLE ATTIC SPACES. 2) FLEXIBLE "WHIPS" FROM JUNCTION BOXES TO RECESSED AND SUSPENDED LIGHTING FIXTURES. 3) CIRCUITING WITHIN CASEWORK AND OTHER "TIGHT" CONDITIONS. 4) WHERE APPROVED FOR INSTALLATION, TYPE MC CABLE SHALL BE SUPPORTED VERTICALLY 5' O.C., HORIZONTALLY T O.C., AND WITHIN 12" OF OUTLET JUNCTION BOXES. 5) PLASTIC BUSHINGS SHALL BE INSTALLED AT ALL TERMINATIONS. F. WIRING: ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRE IN COPPER, STRANDED IN SIZES #8 AWG AND LARGER. INSULATION SHALL BE TYPE THW, THWN OR THHN. G. EXISTING CONDITIONS: ELECTRICAL AND FOOD SERVICE CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIARIZED WITH ALL EXISTING AND PROPOSED CONDITIONS WHICH MAY AFFECT THE COURSE OF HIS WORK PRIOR TO SUBMITTING A BID ON THIS PROJECT. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO COMPLY WITH THIS REQUIREMENT. It 1 s S E ' n t i (continued) H. PERMITS: ELECTRICAL CONTRACTOR SHALL OBTAIN FOR ALL BUILDING AND WORKING PERMITS AND INSPECTION FEES FOR THIS PROJECT, AS APPLICABLE TO SPECIFIC TRADE. I. UTILITY SERVICES: ELECTRICAL CONTRACTOR SHALL PROVIDE POWER AND COMMUNICATIONS SYSTEM SERVICES IN ACCORDANCE WITH THE REQUIREMENTS OF THE SERVING UTILITIES. PROVIDE EXCAVATION, RACEWAY, STRUCTURE, GROUNDING, ETC. AS DIRECTED. POWER SERVICES AND DISTRIBUTION SYSTEM AIC RATING SHALL EXCEED MAXIMUM AVAILABLE FAULT CURRENT THROUGH UTILITY SERVICE TRANSFORMER. CONTACT SERVIING UTILITIES AND OBTAIN THEIR REQUIREMENTS PRIOR TO BID. (UTILITY SERVICE AND LINE EXTENSION CHARGES PAID GC). J. FIRE STOPPING: ELECTRICAL CONTRACTOR SHALL PROVIDE FIRE STOPPING AT ALL PENETRATIONS OF FIRE -RATED ASSEMBLIES. FIRE STOP ASSEMBLIES SHALL BE UL LISTED AND APPROVED BY CODE ENFORCING AUTHORITIES BY APPROPRIATE TRADES. K. FUSES AND CIRCUIT BREAKERS: FUSES AND CIRCUIT BREAKERS SHALL BE SIZED PER ACTUAL NAMEPLATE OF EQUIPMENT SERVED. CIRCUIT BREAKERS SHALL BE RATED FOR THEIR RESPECTIVE APPLICATION (MOTOR CIRCUIT PROTECTOR, GROUND FAULT CIRCUIT INTERRUPTER, ARC FAULT CIRCUIT INTERRUPTER, ETC.). FUSES SHALL BE DUAL -ELEMENT CURRENT -LIMITING, AND SHALL BE INTERCHANGEABLE BETWEEN FRAME SIZES WITH STANDARD FACTORY FUSE REDUCERS. L. EQUIPMENT STANDARDS: ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND OF THE HIGHEST QUALITY AVAILABLE ("SPECIFi%-/—% N' GRADE"J. LIGHTING FIXTURES SHALL HAVE ELECTRONIC BALLASTS AND ACRYLIC LENSES. FOOD SERVICE EQUIPMENT SHALL BE FACTORY -ASSEMBLED COMMERCIAL -GRADE, CONFIGURED PER SERVING UTILITY STANDARDS. M. GUARANTEE: THE ELECTRICAL CONTRACTOR SHALL GUARANTEE THE COMPLETE ELECTRICAL SYSTEM, AND ALL PORTIONS THEREOF, SHALL BE GUARANTEED TO BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED BY THE DEFECTS OR REPAIR THEREOF AT NO EXPENSE TO THE OWNER. LIGHT BULBS ARE EXEMPT FROM THIS GUARANTEE, BUT SHALL BE NEW AND UNUSED AT THE TIME OF FINAL ACCEPTANCE. N. SUBMITTALS: SUBMIT COPIES AS REQUIRED, OF FACTORY SHOP DRAWINGS FOR ALL LIGHTING FIXTURES, SWITCHGEAR, PANELS, MOTOR CONTROL, WIRING DEVICES, ETC. PROPOSED FOR THIS PROJECT, PROPOSED ALTERNATES SHALL BE EQUAL OR SUPERIOR TO SPECIFIED ITEMS IN ALL RESPECTS. DETERMINATION OF EQUALITY RESTS SOLELY WITH ELECTRICAL ENGINEER. 0. LOCATIONS: INDICATED LOCATIONS OF ALL OUTLETS AND EQUIPMENT ARE SUBJECT TO CHANGE. SHIFT/RELOCATE/RECONFIGURE ANY OUTLET, EQUIPMENT OR CONNECTION POINT UP TO 10' AS DIRECTED BY ELECTRICAL ENGINEER, AT NO ADDED COST. P. IDENTIFICATION: ELECTRICAL CONTRACTOR SHALL IDENTIFY ALL EQUIPMENT, SWITCHBOARD CIRCUITS AND ELECTRICALLY -CONNECTED EQUIPMENT WITH ENGRAVED NAMEPLATES. NAMEPLATES SHALL BE FASTENED WITH A MINIMUM OF TWO (2) SCREWS. PANEL DIRECTORIES SHALL BE TYPED. Q. PANELBOARDS: PANELS SHALL HAVE FLUSH MONO -FLAT TRIM, PIANO HINGED DOORS AND COVER (DOOR IN DOOR) WITH LOCKABLE MASTER -KEYED FLUSH CATCHES AND BOLT -ON CIRCUIT BREAKERS. FLUSH MOUNTED PANELS SHALL HAVE EMPTY CONDUITS STUBBED TO ACCESSIBLE SPACE: (1) 1" CONDUIT FOR EACH (4) SPARE/SPACE CIRCUITS. R. TAMPER -PROOF: ALL EQUIPMENT AND CIRCUITING ACCESSIBLE BY THE PUBLIC SHALL BE DEMONSTRATED TO BE TAMPER -PROOF AND VANDAL RESISTANT. OPENABLE DEVICES AND EQUIPMENT SHALL BE PADLOCKABLE. S. SUPPORTS AND HANGERS: SUPPORT AND ALIGN ALL RACEWAYS, CABINETS, BOXES, BACK -BOXES, FIXTURES AND EQUIPMENT FROM STRUCTURE. SECURE ALL SUPPORTING METHODS BY MEANS OF TOGGLE BOLTS IN HOLLOW MASONRY, EXPANSION BOLTS IN SOLID MASONRY, CONCRETE PRESET INSERTS OR EXPANSION BOLTS IN CONCRETE, MACHINE SCREWS OR BOLTS ON METAL SURFACES, AND WOOD SCREWS ON WOOD CONSTRUCTION. ALL SUPPORTING SYSTEMS AND COMPONENTS SHALL BE RATED FOR FIVE (5) TIMES THE ACTUAL LOAD. T. ADDITIONAL SYSTEMS AND EQUIPMENT CONNECTIONS: IN ADDITION TO EQUIPMENT POWER FEEDERS AND CONNECTIONS INDICATED ON THE ELECTRICAL DRAWINGS, PROVIDE 120V CONTROL POWER CONNECTIONS TO SMOKE/FIRE DAMPERS, VAV BOXES, TEMPERATURE CONTROL PANELS, DOOR-HOLDING/LATCHING DEVICES, ETC., AS INDICATED IN THE MECHANICAL DRAWINGS AND SPECIFICATIONS. ITEM POWER SOURCE NO. PER CIRCUT FIRE/SMOKE DAMPER EMERGENCY 5 VAV TERMINAL (NO FAN) NORMAL 7 TEMP CONTROL PANEL EMERGENCY 1 DOOR HOLDING/LATCHING DEVICE 4 U. 24-HOUR OPERATION: IF APPLICABLE, CONDUCT WORK TO MINIMIZE DISRUPTION OF OWNER'S ONGOING 24-HOUR OPERATIONS. PROVIDE BARRICADES, NOISE ABATEMENT AND DUST CONTAINMENT MEASURES TO ENSURE THE SAFETY AND COMFORT OF PATRONS, STAFF AND WORKERS. INTERRUPTIONS OF EXISTING POWER, COMMUNICATIONS OR FIRE ALARM SYSTEMS SHALL BE MOMENTARY IN NATURE, EACH SUCH OUTAGE (OR OPERATION WHICH MAY POSE RISK OF AN ACCIDENTAL OUTAGE) SHALL BE SCHEDULED 48 HOURS IN ADVANCE. �rt Fu"D � �� �. 1 a � C E SYSTEM NOTES 1. THESE DRAWINGS INDICATE ELECTRICAL FEEDS ONLY TO FOOD SERVICE EQUIPMENT AND SYSTEMS. SEE KITCHEN DRAWINGS (FS-SERIES) PREPARED BY THE FOOD SERVICE CONSULTANT FOR EXPLANATIONS OF LOADS, SYMBOLS MOUNTING HEIGHTS, ETC. - AND FOR ADDITIONAL ELECTRICAL REQUIREMENTS NOT INDICATED ON THESE DRAWINGS, INCLUDING: EXTENSIONS TO EQUIPMENT FROM OUTLET BOXES, SPECIALTY RECEPTACLES, CORD SETS, MULTIPLE CONNECTIONS FROM SINGLE OUTLETS, POWER AND CONTROL INTERCONNECTIONS FROM COMPRESSOR RACK TO FIELD EQUIPMENT AND MISCELLANEOUS POWER AND CONTROL INTERCONNECTIONS. 2. SEE OVERALL FOOD SERVICE DRAWINGS FOR DESCRIPTIONS OF EQUIPMENT AND SYSTEMS. 3. ALL CONDUIT STUB -UPS, AS INDICATED ON THE KITCHEN EQUIPMENT DRAWINGS, SHALL BE ROUTED BELOW FINISHED FLOOR, %4" MIN, UNLESS OTHERWISE NOTED AS LARGER. 4. ALL RECEPTACLES WITHIN 6FT OF SINKS OR WATER USE AREAS SHALL BE 'GFCI' TYPE. 5. ALL DEVICE COVER PLATE COLOR AND MATERIALS TO BE SELECTED BY ARCHITECT TO COORDINATE WITH THE COMPLETE PROJECT. 6. PROVIDE "TAYMAC" #Sl/2G SERIES WEATHERPROOF RECESSED RECEPTACLE COVERS FOR ALL ABOVE COUNTER RECEPTACLES IN BAR AND SINK AREAS. 7. FINAL CONNECTION TO ALL KITCHEN EQUIPMENT SHALL BE MADE WITH 'SEAL -TITS' FLEXIBLE CONDUIT. 8. PROVIDE MOISTURE PROOF SEAL OFF FOR ALL CONDUITS ENTERING/LEAVING COOLER AND FREEZER BOXES. ASSEMBLE, INSTALL AND LAMP, LIGHTING FIXTURES AND WIRING DEVICES PROVIDED WITH COOLERS AND FREEZERS. PROVIDE COMPLETE INTERNAL CIRCUITING AND CONNECTIONS. 9. PROVIDE POWER INTERCONNECTION BETWEEN FREEZER FAN COILS, DEFROST HEATERS AND COMPRESSOR RACKS. MINIMUM CIRCUITING = 5 #12, 1"C. CONFIRM REQUIREMENTS PRIOR TO ROUGH -IN. 10. ALL EQUIPMENT LOCATED BELOW EXHAUST HOODS WITHIN FOOD PREPARATION AREAS SHALL BE SERVED BY SHUNT -TRIP TYPE CIRCUIT BREAKERS INTERLOCKED WITH THE HOOD FIRE SUPPRESSION SYSTEM. UPON ACTIVATION OF THE FIRE SYSTEM, THE SHUNT -TRIP CIRCUIT BREAKERS SHALL TRIP TO THE 'OFF' POSITION. 11. KITCHEN HOOD EXHAUST FANS AND MAKE-UP AIR UNITS SHALL BE INTERLOCKED AND THE CONTROL CIRCUITS SHALL BE ROUTED THROUGH DRY CONTACTS PROVIDED IN THE FIRE PROTECTION SYSTEM. PROVIDE ADDITIONAL RELAYS AS REQUIRED. 12. PROVIDE 120V SERVICE AND CONNECTIONS TO GAS SOLENOID VALVES. INTERCONNECT WITH HOOD CONTROL AND FIRE SUPPRESSION SYSTEMS. 13. SUPPLEMENTAL TASK LIGHTING: PROVIDE (15) 24" LONG LOCAL AND UNDERCOUNTER TASK LIGHTS, COMPLETE WITH LAMPS, INTEGRAL SWITCH, CORD SET AND/OR LOCAL OUTLET AS REQUIRED. "ALKCO" # SF300 SERIES. LOCATE AS DIRECTED FOR SUPPLEMENTAL TASK LIGHTING, OR AS REQUIRED TO PROVIDE 50 FOOT-CANDLE LIGHT LEVELS. RETURN EXCESS TO OWNER. 14. PROVIDE RACEWAY SYSTEMS FOR REFRIGERATION AND BEVERAGE SERVICE LINES AS DIRECTED IN FOOD SERVICE DRAWINGS (ALL LONG -RADIUS SWEEPS). PROVIDE PULL CANS AND GUTTERS AS REQUIRED. ASSEMBLE ALL RACEWAY SYSTEM JOINTS WITH SILICONE CAULK, TO PROVIDE A CONTINUOUS WATERTIGHT ASSEMBLY. E L L '� C 1L Sy Mali � LS THE FOLLOWING SYMBOLS MAY BE USED IN THE DRAWINGS: ELECTRICAL LEGEND SYMBOLS ABBREVIATIONS OJUNCTION BOX (]-BOX) A AMPERES ❑ EQUIPMENT INTERCONNECTION BY E.C. AFF ABOVE FINISHED FLOOR ® ELECTRICAL ROUGH -IN BTC BRANCH TO CONNECTION POINT AND CONNECT EQUIPMENT SINGLE ELECTRICAL OUTLET (SCO) CONY. CONVENIENCE OUTLET 120V 1PH 2O.OA DUPLEX ELECTRICAL OUTLET (DCO) D.C. DIRECT CONNECTION FOUR PLEX ELECTRICAL OUTLET (QCO) DN DOWN FROM ABOVE O STUB UP FROM FIN FLOOR (TERMINATED CONDUIT) E.C. ELEECTRICAL CONTRACTOR TELEPHONE OUTLET HP HORSE POWER O DATA LINE CONNECTION K.E.C. KITCHEN EQUIPMENT CONTRACTOR BREAKER PANELBOARD SWITCH AS NOTED KW KILOWATTS PH PHASE FLOOR BOX (FL. BOX) U.C. UNDER COUNTER V VOLTS W WATTS (E) Existing (X) Existing to be removed (R) Relocate NIC Not In Contract U.O.N. Unless Otherwise Noted + Above Finished Floor DN+ Down from ceiling to height above Finished Floor FBGC Furnished BY GC FF & E Fixtures Furnishings and Equipment E.C. Electrical Contractor C Conduit (with pull cord if otherwise empty) C.O. Conduit only CONN Connection GFCI Ground Fault Circuit Interrupter JB Junction Box SR Single Recptacle DR Duplex Recptacle BP Breaker Panel PI Plug In HP Horsepower GRD/GND Ground V Volts KW Kilowatt (Watt x 1000) A Amp P/W Phase / Wire STATE PROJECT NO. 132-0089 N Phase 2 of 5 `�ew.®9pp°nP�p°��F9op0� ° 4 * 47020 ` r • ; a1® v RJS + ASSOCI_ATES INTEGRATED FOOD SERVICE DESIGN P.O. SOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860,434.2700 F: 860.434.3735 wnwi.rjsfsd.com MOS�R PIL N 1 v E N ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT ELECTRICAL NOTES DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. FS-Ell REVISIONS CONFORMED SET MARCH 22, 2019 A 2-19-2019 BID SUPPLEMFNT 1 A 2-22-2019 BID SUPPLEMENT 2 M N T P L U MB"6`1 N G R'-:\\ I Ez 0 U H R E GENERAL NOTES: A. ALL WORK INDICATED ON THE PLUMBING ROUGH -IN PLAN MUST BE COMPLETED BY OTHER THAN THE KITCHEN EQUIPMENT CONTRACTOR AND MUST COMPLY WITH ALL LOCAL CODES AND RESTRICTIONS. B. THE PLUMBING ROUGH -IN PLAN IS INTENDED TO SHOW PIPE SIZES, ROUGH -IN HE1G1_j I S AND LOklm I I^vNS AIVD CONSUI IP I IrON vv--k I ES FOR FOOD SE-1-Mh.0 EQUIPMENT ONLY. ANY ADDITIONAL PLUMBING REQUIREMENTS ARE THE RESPONSIBILITY OF THE PLUMBING ENGINEER AND MUST COMPLY WITH ANY APPLICABLE CODES AND REGULATIONS. C. REFER TO THE APPROVED SHOP DRAWINGS FOR THE SUPPLEMENTAL COORDINATION AND INSTALLATION REQUIREMENTS FOR THE FOOD SERVICE EQUIPMENT INDICATED ON THE PLANS. D. ALL SERVICES FOR THE EXISTING AND OWNER OR PURVEYOR PROVIDED EQUIPMENT MUST BE VERIFIED WITH THE EQUIPMENT. ANY UTILITIES INDICATED ON THE PLANS ARE MINIMUM GUIDELINES ONLY AND MUST BE VERIFIED WITH THE EQUIPMENT. CONTACT EQUIPMENT PROVIDER FOR THE LOCATION OF, OR SPECIFICATIONS FOR, THIS EQUIPMENT. E. PRIOR TO THE INSTALLATION OF THE FOOD SERVICE EQUIPMENT, THE KITCHEN EQUIPMENT CONTRACTOR MUST CONFIRM THAT THE WATER, GAS AND/OR STEAM LINES WERE PREVIOUSLY PRESSURE TESTED, FLUSHED FREE OF FOREIGN MATTER, VALVED OFF AND TAGGED WITH THE APPROPRIATE LABELS. PLUMBING CONTRACTOR NOTES: PLUMBING CONTRACTOR IS RESPONSIBLE FOR INSTALLING THE FOLLOWING, AND FOR MAKING ALL FINAL CONNECTIONS TO THE FOOD SERVICE EQUIPMENT UNLESS OTHERWISE NOTED. A. INSTALL AND COMPLETE HAND SINK ASSEMBLIES. VERIFY COMPLIANCE WITH LOCAL CODES AND REGULATIONS. B. INSTALL HOSE BIBB ASSEMBLY WITH A FAUCET WITH GARDEN HOSE THREAD, MIXING VALVE AND VACUUM BREAKER WHERE SHOWN ON THESE FOOD SERVICE PLUMBING ROUGH -IN DRAWINGS. C. PRESSURE REDUCING OR REGULATING VALVES, FAUCETS AND WATER INLETS, IN -LINE WATER FILTERS AND VACUUM BREAKERS, NOT OTHERWISE SUPPLIED TO FOOD SERVICE EQUIPMENT, AS REQUIRED BY LOCAL CODES AND MANUFACTURERS SPECIFICATIONS. D. WASTE LINES, DIRECT AND INDIRECT, SHALL BE A MINIMUM 1" DIA. REGARDLESS OF CONNECTION SIZE, TO BE PITCHED DOWNWARD AND TO HAVE ADEQUATE CLEAN -OUT PROVISIONS. INDIRECT WASTE LINES FROM WALK-IN COOLER/FREEZERS MUST BE PITCHED 4"/12" MINIMUM WITH AN IN -LINE "P" TRAP OVER FLOOR SINK. EACH EVAPORATOR IS TO HAVE A SEPARATE DRAIN LINE. E. AREA DRAINS AND FLOOR SINKS COMPLETE WITH TOP GRATES INDICATED AND REMOVABLE SEDIMENT BUCKET. FLOOR SINK TOP TO BE SET FLUSH WITH THE FINISHED FLOOR. VERIFY COMPLIANCE WITH LOCAL CODES AND REGULATIONS. F. GREASE TRAPS AS REQUIRED. INSTALL GREASE TRAPS OUTSIDE OF BUILDING WHENEVER POSSIBLE. INSTALLATION WITHIN THE BUILDING MUST COMPLY WITH LOCAL CODES AND REGULATIONS. NOTIFY RJS ASSOCIATES WHEN INSTALLATION MUST BE WITHIN ANY OF THE KITCHEN AREAS. G. ALL REQUIRED MATERIALS TO MAKE FINAL CONNECTIONS TO ALL FOOD SERVICE EQUIPMENT INDICATED ON THESE PLANS. H. NOTES CONCERNING PLUMBING ROUGH -INS: 1) FURNISH AND INSTALL ALL WATER, WASTE, GAS AND STEAM LINES AND SIZE SERVICE TO PROVIDE FULL FLOW VOLUME FOR ALL EQUIPMENT SUPPLIED BY RESPECTIVE MAINS AND BRANCHES. PROVIDE STOP VALVES AND TAG ROUGH -INS WITH THE APPROPRIATE IDENTIFYING LABELS. SERVICE LINES STUBBED OUT OF WALLS, UP FROM FINISHED FLOORS OR A CONCRETE CURB A MINIMUM OF 2". VENT PIPES MUST BE CONCEALED IN WALLS OR COLUMN CHASE. USE A LOOP -VENT OR AIR GAP ASSEMBLY FOR ISLAND FIXTURES. ALL FLOOR PENETRATIONS MUST BE SEALED WATERTIGHT. 2) WASTE LINES SHOWN ARE DESIGNED TO COMPLY WITH THE BEST KNOWN AND GENERALLY ACCEPTED HEALTH AND SANITARY CONDITIONS AND CODES. PLUMB LINES TO ENSURE NO INTERFERENCE WITH THE INTENDED USE OR SERVICING OF FOOD SERVICE EQUIPMENT. RUN LINES BELOW THE EQUIPMENT AT THE HIGHEST POSSIBLE ELEVATION ABOVE FINISHED FLOOR. NO LINES ARE TO LAY ON THE FLOOR. VERIFY COMPLIANCE WITH LOCAL CODES AND REGULATIONS. 3) SUPPLY 140OF HOT WATER TO EQUIPMENT. INSULATE WATER AND STEAM LINES TO CONFORM WITH THE ACCEPTED PRACTICE. IT IS RECOMMENDED THAT EXPOSED PIPES AND FITTINGS ABOVE A WORKING HEIGHT OF 34" BE CHROME PLATED OR COVERED WITH A STAINLESS STEEL SLEEVE. 4) SIZE FUEL GAS SERVICE LINES TO PROVIDE THE REQUIRED BTU RATING INDICATED FOR THE EQUIPMENT, AT A LOW PRESSURE OF APPROXIMATELY 7" TO 9" WATER COLUMN. INSTALL AUTOMATIC MECHANICAL SHUT-OFF VALVES, FURNISHED BY FIRE SUPPRESSION SYSTEM CONTRACTOR, IN GAS SUPPLY LINES TO EQUIPMENT UNDER EXHAUST HOOD ASSEMBLIES. VERIFY COMPLIANCE WITH LOCAL CODES AND REGULATIONS s u w REC.�%'URI I14!kIIII,1 x ENTS (CONTINUED) PLUMBING CONTRACTOR NOTES: (CONTINUED.) I. NOTES CONCERNING PLUMBING CONNECTIONS: a) ALL WATER, GAS AND STEAM SERVICES FOR PORTABLE AND COUNTER TOP EQUIPMENT MUST BE CONNECTED TO THE EQUIPMENT WITH COMMERCIAL TYPE FLEXIBLE HOSE AND QUICK DISC:ONNEC'I FITTINGS. T INGS. HOSES MUST BE COVERED WITH A FIRE RESISTANT PLASTIC OR POLY COATING. GAS ASSEMBLIES MUST BE A.G.A. APPROVED FOR COMMERCIAL KITCHEN EQUIPMENT. b) WATER TO STEAM PRODUCING EQUIPMENT MUST HAVE A WATER HARDNESS NO GREATER THAN 2.0 GRAINS AND A PH LEVEL BETWEEN 7.0 00 7.5. WATER USED FOR COOLING WATER TO CONDENSING UNITS OR COMPRESSORS MUST BE TREATED TO INHIBIT THE FORMATION OF DEPOSITS IN THE CONDENSING TUBES. c) STEAM THAT COMES IN DIRECT CONTACT WITH FOOD, FOOD HOLDING EQUIPMENT OR WAREWASHING EQUIPMENT MUST BE POTABLE STEAM. d) INTERPIPE HOT WATER SUPPLY LINES BETWEEN BOOSTER HEATER AND WAREWASHING EQUIPMENT. e) INTERPIPE WATER LINES BETWEEN WATER WASH VENTILATOR ASSEMBLIES AND CONTROL PANELS. REFER TO MANUFACTURERS SPECIFICATIONS FOR EXACT REQUIREMENTS. r) MANIFOLD WASTE AND WASTE CONNECTIONS FOR INDIVIDUAL SECTIONS OF WATER WASH VENTILATORS TO A MAIN DRAIN CONNECTION. VERIFY CODE COMPLIANCE. g) INTERCONNECT WASTE PULPER, EXTRACTOR AND SCRAP TROUGH AS PER MANUFACTURERS SPECIFICATIONS. h) INSTALL IN -LINE WATER FILTERS AS FURNISHED BY KITCHEN EQUIPMENT CONTRACTOR. PLUMBERS NOTES: A. PLUMBING CONTRACTORS TO OBTAIN ALL NECESSARY PERMITS AND INSTALLATION IS TO BE IN COMPLETE ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL CODES. B. PLUMBING CONTRACTORS SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE ALL FINAL CONNECTIONS AND SHALL INCLUDE ALL ITEMS REQUIRED BY APPLICABLE LAWS. C. A CATALOG OF MANUFACTURERS EQUIPMENT SPECIFICATION SHEETS IS INCLUDED AS AN INTEGRAL PORTION OF THIS SUBMITTAL, WE SUGGEST THFPFF(1RE THAT ALI TR81lFC RF\/TP%A/ T14P RFY11 ITRFMFnITC AC TIMr)T('ATFr) . _- 6.-_ 1\.4.,v.GL,tiv ! 1 !L J "l 11 tlSJ!li/-l11-6.J REGARDING EACH MANUFACTURER. D. CROSS REFERENCE ALL INFORMATION PER ROUGH -IN DRAWINGS WITH THE EQUIPMENT SCHEDULE DRAWINGS. E. PLUMBING CONTRACTORS TO CROSS REFERENCE ROUGH -IN DRAWINGS, STAINLESS STEEL FABRICATION, WALK-IN DRAWINGS, EXHAUST HOOD DRAWINGS AND MILLWORK DETAIL DRAWINGS. F. ALL VENT LOCATIONS AND RUNS TO BE LOCATED BY MECHANICAL ENGINEER. G. ALL FUNNEL FLOOR DRAINS, FLOOR SINKS AND/OR FLOOR DRAINS UTILIZED FOR THE DRAINAGE OF FOOD SERVICE EQUIPMENT SHALL BE SELF -PRIMING. H. PLUMBING CONTRACTOR TO PROVIDE ALL INDIRECT DRAINS FROM EQUIPMENT TO FLOOR SINK DRAINS. I. ALL PLUMBING TO BE INSTALLED AS TO PRECLUDE ANY POSSIBILITY OF BACK SIPHONAGE, J. ALL INDIRECT DRAINS ARE TO BE AIR -GAPPED 1 1/2 x DIAMETER OF PIPE, ABOVE FLOOR DRAINS (OR PER LOCAL CODE). K. PLUMBING CONTRACTOR TO PROVIDE REQUIRED PRESSURE REGULATING VALVES FOR HOT WATER LINE TO DISHWASHER RINSE CONNECTION AND ALL OTHER EQUIPMENT REQUIRING REGULATORS. L. PLUMBER IS NOT RESPONSIBLE FOR SUPPLYING FAUCETS UNLESS SPECIFIED. M. PLUMBER TO PROVIDE MIXING VALVE AT WATER HEATER SO THAT A MINIMUM OF 1400 WATER IS DELIVERED TO BOOSTER HEATER, OR AS DESIGNED BY MECHANICAL ENGINEER. PLUMBING SYMB0LS-_-3', THE FOLLOWING SYMBOLS MAY BE USED IN THE DRAWINGS: PLUMBING LEGEND S Y M B O L S ABBREVIATIONS ® HOT WATER AFF ABOVE FINISHED FLOOR O CVLD VYA 1 ER BTC UR INI_l I TO CONIN'ECTI p DRAIN CONNECTION CW COLD WATER to DIRECT DRAIN DN DOWN FROM ABOVE O WATER CONNECTION DR DRAIN FLOOR SINK HALF GRATE FD FLOOR DRAIN O FLOOR DRAIN AS NOTED FS FLOOR SINK FUNNEL DRAIN AS NOTED FT FLOOR TROUGH ® GAS LINE GPH GALLONS PER HOUR ® GAS CONNECTION GPM GALLONS PER MINUTE ® CHILLED WATER HD HUB DRAIN FLEX CONNECT HOSE HW HOT WATER ------- INDIRECT WASTE LINE P PLUMBING PLUMBING INTERCONNECTION PSI POUNDS PER SQUARE INCH 0 STUB UP FROM FIN FLOOR DW DIRECT WASTE IW INDIRECT WASTE CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN (E) EXISTING (X) EXISTING TO BE REMOVED (R) RELOCATE NIC NOT IN CONTRACT U.O.N. UNLESS OTHERWISE NOTED FBGC FURNISHED BY GC FF & E FIXTURES FURNISHINGS AND EQUIPMENT ( + ) ABOVE FINISHED FLOOR DN ( +) DOWN FROM CEILING TO HEIGH7i'iir ABOVE ABOVE FINISHED FLOOR CONN CONNECTION CW COLD WATER W 140 DEGREE HOT WATER MW MIXED WATER DW DIRECT WASTE IW INDIRECT WASTE CR CONDENSATE RETURN FD FLOOR DRAIN GPM GALLONS PER MINUTE C M BTU H 1000 BTU/H R TWR TOWER WATER RETURN TWS TOWER WATER SUPPLY P.C. PLUMBING CONTRACTOR VC VALVE COMPARTMENT CFM CUBIC FEET PER MINUTE FPM FEET PER MINUTE SR STEAM RETURN STATE PROJECT NO. 132-0089 N Phase 2 of 5 oQq°.g°F499444tP://lr/A 0 °s Lze AIi RJS -I- ASSOCIATES INTEGRATED'FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434,3735 wmv.gsfsd.com MOSER ILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT SS STEAM SUPPLY I PLtJMBING NOTES DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. REVISIONS CONFORMED SET MARCH 22, 2019 2-19-2019 BIDSUPPLENIENT 1 2-22-2019 BID SUPPLEMENT 2 GEINJERAL ME CHANI CAL INOTES (THESE NOTES SUPPLEMENT THE MASTER SPECIFICATIONS) CONDITIONS A. GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, SPECIAL CONDITIONS, AND OTHER RELATED PORTIONS OF DIVISION 1 APPLY TO THIS SECTION. REGULATIONS, CODES, PERMITS AND INSPECTIONS A. COMPLY WITH ALL NATIONAL; STATE; COUNTY AND CITY CODES; ORDINANCES, ETC. HAVING JURISDICTION, INCLUDING RULES AND REQUIREMENTS OF UTILITY SERVING AGENCIES. B. INCORPORATE ALL CODES, ORDINANCES, ETC. INTO THE BASE BID AND INSTALLATION OF THE WORK. NO ADDITIONAL FUNDS WILL BE ALLOCATED FOR WORK REQUIRED TO CONFORM TO REGULATIONS AND REQUIREMENTS AND/OR TO OBTAIN APPROVAL OF WORK. C. OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND LICENSES. WHEN REQUIRED BY CODE, ALL WORK MUST BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TO FINAL APPROVAL, FURNISH ARCHITECT WITH CERTIFICATES OF INSPECTION AND APPROVALS BY LOCAL AUTHORITIES. D. IN ADDITION, THE LATEST EDITION OF THE FOLLOWING PUBLISHED STANDARDS SHALL BE ADHERED TO: 1. CT STATE BUILDING,MECH, & PLUMB CODE 4. APPLICABLE NFPA STANDARDS 5. ASHRAE GUIDES 6. SMACNA DUCT CONSTRUCTION STANDARDS 7. NATIONAL ELECTRIC CODE e. HEAL I H CODES 9. NATIONAL FIRE CODE DUCTWORK A. PROVIDE A COMPLETE SYSTEM OF DUCTWORK, FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE ASHRAE GUIDES AND WITH SMACNA DUCT CONSTRUCTION STANDARDS. THE DUCT SYSTEM SHALL BE CONSTRUCTED AS SHOWN ON THE MECHANICAL DRAWINGS. CHANGES IN ARRANGEMENT OR IN DUCT SIZES SHALL BE MADE ONLY AFTER WRITTEN l EN ACCEPTANCE IS OBTAINED FROM THE MECHANICAL CONSULTING ENGINEER. DUCTWORK INSTALLATION A. CONSTRUCT DUCTWORK WITH MATERIAL, GAUGES, JOINTS, WELDS, BRACING AND SUPPORTS IN ACCORDANCE WITH APPLICABLE RECOMMENDATIONS OF ASHRAE AND SMACNA WITH ADDITIONAL BRACING AS REQUIRED. B. FOOD SERVICE EXHAUST DUCTWORK SHALL BE RIGIDLY CONSTRUCTED, LIQUID AND AIR -TIGHT. JOINTS SHALL BE TIGHTLY FITTED AND WELDED WITH NO VOIDS. ALL DUCTWORK, SEALING PRODUCTS SHALL CONFORM TO THE UMC AND UL-181 AND INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS. TESTING AND BALANCING A. THE TESTS SHALL TNCL IOF Al I FANS vni I IMF f3AMPFRS- ATR DEVICES, ETC. NORMALLY INCLUDED AS A PART OF THE AIR DISTRIBUTION AND TRANSMISSION SYSTEM. B. A COMPLETE BALANCING REPORT SHALL BE DONE BY AN INDEPENDENT BALANCING COMPANY AND SHALL BE SUBMITTED TO THE CONSULTING ENGINEER UPON COMPLETION. PLUMBING AND PIPING SPECIFICATIONS GENERAL PRODUCTS A. FURNISH AND INSTALL NEW EQUIPMENT AND MATERIALS. ITEMS OF EQUIPMENT USED FOR THE SAME PURPOSE SHALL BE BY THE SAME MANUFACTURER. B. SYSTEMS SHALL BE COMPLETE AND OPERABLE. ANY ACCESSORIES REQUIRED FOR OPERATION OF THE SYSTEMS SHALL BE INCLUDED AS AN ITEM OF EQUIPMENT. WHERE POSSIBLE, ALL VALVES SHALL BE CONCEALED WITHIN FIXTURE OR EQUIPMENT. PIPING MATERIALS A. WATER PIPING BURIED BELOW GRADE SHALL BE TYPE "K" COPPER TUBING WITH WROUGHT COPPER FITTINGS WITH SILVER SOLDER. B. DOMESTIC AND CHILLED WATER PIPING ABOVE GRADE SHALL BE TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT COPPER FITTINGS AND NO -LEAD 95/5 SOLDER. C. NATURAL GAS PIPING ABOVE GRADE THAT IS 2.5" AND SMALLER SHALL BE SCHEDULE 40 ASTM, A-53 BLACK STEEL SCREWED PIPE WITH BLACK BANDED 150C/O MALLEABLE IRON THREADED FITTINGS. PIPING 3" AND LARGER SHALL BE BUTT -WELDED WITH FACTORY MADE WROUGHT STEEL BUTT WELDING FITTINGS. D. CONDENSATE DRAIN PIPING SHALL BE TYPE "M" HARD COPPER WITH WROUGHT COPPER FITTINGS AND NO -LEAD 55 SOLDER. E. GAS VALVES SHALL BE BRONZE BODY, BRONZE TAPERED PLUG, NON -LUBRICATED TEFLON PACKING, THREADED ENDS. GAS VALVES ARE PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR. GAS VALVE SUPPORTING FIRE PROTECTION SHALL BE COMPATIBLE TO FIRE CONTROL LOGIC AS DESIGNED BY MECHANICAL ENGINEER. F. PIPE SUPPORTS SHALL BE AS REQUIRED BY LATEST EDITION OF THE UPC. 5 MECHANICAL - G f !.._Rt . NOTES PIPING SPECIALTIES INSTALLATION A. CONCEAL ALL PIPING IN WALLS, FURRED SPACES, PIPE SPACES, OR ABOVE SUSPENDED CEILINGS, AS SHOWN ON THE DRAWINGS. GROUP PIPING WHEREVER PRACTICAL, AND INSTALL UNIFORMLY IN STRAIGHT PARALLEL LINES, SQUARELY WITH BUILDING LINES, AS APPLICABLE. B. SUPPORT HORIZONTAL PIPING WITH PIPE HANGERS. DO NOT USE PERFORATED METAL STRAP. ARRANGE PIPING SO THAT THERMAL EXPANSION DOES NOT CAUSE STRESS. INSTALL AND SECURE PIPING SO THAT HOT AND COLD LINES AND LINES OF DISSIMILAR METALS ARE NOT IN CONTACT. ALLOW FOR THERMAL EXPANSION AS REQUIRED. C. VERIFY ALL EQUIPMENT DIMENSIONS AND REQUIREMENTS FOR ROUGH -IN WORK, COORDINATE BETWEEN KITCHEN EQUIPMENT CONTRACTOR AND PLUMBING CONTRACTOR. D. PERFORM ALL WORK IN ACCORDANCE WITH THE BEST TRADE PRACTICES. INSTALL ALL MATERIALS AND EQUIPMENT SQUARELY WITH THE BUILDING LINES. PROVIDE RIGID, PERMANENT BASES AND SUPPORTS FOR ALL WORK. CONSTRUCT AND BRACE EQUIPMENT, PIPING. FTC. SO THAT THFRF WTI I BF Nn VTRRATTnN ANn/nR RATTLING WHEN THE SYSTEM IS IN OPERATION. STRUCTURAL HANGARS A. HANGERS SUPPORTED BY METAL DECKING ONLY, OR METAL DECKING WITH INSULATED FILL, SHALL BE ATTACHED WITH STEEL BARS, %" ROUND X 12" 1%" X FLAT 12" PLACED PERPENDICULAR TO FLUTES. ONLY LIGHT DUCTWORK (12" X 16" MAX), PIPING (1 %" ROUND PIPING MAX), OR CEILINGS MAY BE HUNG FROM SUCH INSTALLATIONS. HANGERS MUST BE TWO (2) FLUTES APART WHERE THEY OCCUR ON THE SAME DECK SPAN. B. HANGARS SUPPORTED BY METAL DECK WITH STRUCTURAL CONCRETE FILL SHALL BE INSTALLED USING ICBO APPROVED ANCHORAGE SYSTEMS. SUCH HANGARS SHALL BE USED TO SUPPORT DUCTWORK (54" X 16" MAX), PIPING (4" ROUND MAX) OR CEILINGS. HANGERS MUST BE AT LEAST TWO (2) FLUTES APART WHERE THEY OCCUR ON THE SAME DECK SPAN. LARGER DUCTWORK OR PIPING SHALL BE SUPPORTED BY STRUCTURAL BEAMS OR COLUMNS. CONCRETE A. FORMS FOR CONCRETE CURBS AND DEPRESSIONS SHALL BE LAID OUT AND CONSTRUCTED TO PROVIDE THE SPECIFIED CAMBER SHOWN ON DRAWINGS. B. DRY PACK OR GROUT UNDER BASE PLATES, SILL PLATES, ETC. SEE SPECIFICATIONS. C. MECHANICAL PIPES AND ELECTRICAL CONDUITS WHICH PASS THROUGH SLAB ON GRADE, CONCRETE ON STEEL DECK, FRAMED CONCRETE FLOORS AND WALLS DO NOT REQUIRE SLEEVES, UNLESS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS, MECHANICAL OR ELECTRICAL DRAWINGS. IF SLEEVES ARE REQUIRED, INSTALL SLEEVES BEFORE PLACING CONCRETE. DO NOT CUT ANY REINFORCING WHICH MAY INTERFERE WITH SLEEVE PLACEMENT. CORING OPENINGS IN CONCRETE IS NOT PERMITTED. NOTIFY THE STRUCTURAL ENGINEER IN ADVANCE OF CONDITIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS. NO PIPES OR ELECTRICAL CONDUIT SHALL PASS THROUGH BEAMS OR COLUMNS UNLESS SPECIFICALLY DETAILED. D. EXCEPT FOR SLAB ON GRADE AND CONCRETE ON STEEL DECK, EMBEDDED ELECTRICAL CONDUITS OR MECHANICAL PIPES (OTHER THAN THOSE PASSING THROUGH) OUTSIDE DIAMETER SHALL NOT EXCEED 30 PERCENT OF THE SLAB THICKNESS AND SHALL BE PLACED BETWEEN THE TOP AND BOTTOM REINFORCING, UNLESS SPECIFICALLY DETAILED OTHERWISE. CONCENTRATIONS OF ELECTRICAL CONDUITS OR MECHANICAL PIPES SHALL BE AVOIDED EXCEPT WHERE DETAILED OPENINGS ARE PROVIDED. FOR SLAB ON GRADE, UNLESS OTHERWISE DETAILED, NO PIPES OR CONDUITS SHALL BE PLACED WITHIN THE INDICATED CONCRETE SLAB THICKNESS AND SHALL BE LOCATED BELOW THE SLAB. 1 I 1 Of � r IIVERv 3 k .¢i GENERAL NOTES: A. ALL WORK INDICATED ON THE BUILDING CONDITIONS AND VENTILATION PLAN MUST BE COMPLETED BY OTHER THAN THE KITCHEN EQUIPMENT CONTRACTOR AND MUST COMPLY WITH ALL LOCAL CODES AND RESTRICTIONS. B. THE BUILDING CONDITIONS AND VENTILATION PLAN IS INTENDED TO SHOW SPECIAL BUILDING AND VENTILATION REQUIREMENTS FOR THE FOOD SERVICE EQUIPMENT ONLY. ANY ADDl 11VInVAL uUl LDlINVG CONDITIONS OR VENTILATION REQUIREMENTS ARE THE RESPONSIBILITY OF THE ARCHITECT OR MECHANICAL ENGINEER AND MUST COMPLY WITH ANY APPLICABLE CODES AND REGULATIONS. REFER TO ARCHITECTURAL/ENGINEERING PLANS. C. REFER TO THE APPROVED SHOP DRAWINGS FOR THE SUPPLEMENTAL COORDINATION AND INSTALLATION REQUIREMENTS FOR THE FOOD SERVICE EQUIPMENT INDICATED ON THE PLANS. D. REQUIREMENTS INDICATED ON THE PLANS FOR THE EXISTING AND OWNER OR PURVEYOR PROVIDED EQUIPMENT ARE MINIMUM GUIDELINES ONLY AND MUST BE VERIFIED WITH THE EQUIPMENT. FURNISH SERVICES AND MAKE ALL FINAL CONNECTIONS AS REQUIRED. CONTACT EQUIPMENT PROVIDER FOR THE LOCATION OF, OR SPFCTFTCATT0NIC FnR TI-ITC Fni ITDMFNIT , 1 11J 1-�V11 1-ILItl 1 E. PRIOR TO THE INSTALLATION OF THE FOOD SERVICE EQUIPMENT THE KITCHEN EQUIPMENT CONTRACTOR MUST CONFIRM THAT: 1) THE WALLS, CEILINGS AND FLOORS IN THE KITCHEN, FOOD PREPARATION, WAREWASHING OR BAR AREAS ARE SMOOTH, EASILY CLEANABLE NONABSORBENT AND DURABLE. WALLS AND CEILINGS SHALL BE LIGHT IN COLOR. 2) T HE CEILINGS ARE INSTALLED AND FINISHED. 3) THE WALLS ARE INSTALLED AND FINISHED. 4) THE FLOORING HAS BEEN INSTALLED AND WASHED CLEAN, 5) A LOADING DOCK IS AVAILABLE AND TO COORDINATE WITH THE APPLICABLE TRADESMEN ANY DOOR OR WINDOW OPENINGS OR PASSAGES FOR THE DELIVERY OF THE FOOD SERVICE EQUIPMENT. F. THE MOUNTED HEIGHT FOR THE BOTTOM EDGE OF THE HOODS TO BE 6'-8" ABOVE THE FINISHED FLOOR OR PER LOCAL CODE REQUIREMENTS. MECHANICAL CONTRACTOR NOTES MECHANICAL ENGINEER IS RESPONSIBLE FOR SPECIFYING THE FOLLOWING. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND THE INSTALLING OF THE FOLLOWING, AND FOR MAKING FINAL CONNECTIONS TO THE FOOD SERVICE EQUIPMENT UNLESS OTHERWISE NOTED. A. THE INSULATION FOR ALL COOKING EQUIPMENT EXHAUST HOODS AND DUCTS AS REQUIRED BY LOCAL CODES. B. THE HORIZONTAL DUCTWORK FOR ALL DISH/UTENSIL WASHERS. ALL DUCTS MUST HAVE WATER TIGHT JOINTS AND BE GRADED BACK TO THE MACHINE. (DO NOT USE ALUMINUM DUCTS.) C. BALANCED SUPPLY AND EXHAUST AIR IN KITCHEN AREAS TO CONTAIN COOKI wG ODORS AND PROVIDE A COMFORTABLE `JtIORKING ENVIRONMENT. TEMPER MAKE-UP AIR SUPPLY IN ALL KITCHEN AREAS, ESrr_�,IALLY SUPPLY AIK I HKOUGH EXHAUS I HUUUJ. VEKTrr Alvu COMPLY WITH ALL APPLICABLE CODES. D. THE DUCT COLLARS ON EXHAUST HOODS MAY BE OVERSIZED TO INCREASE EFFICIENCY. PROVIDE ALL TRANSITIONS TO DUCTS AS REQUIRED AND MAKE ALL FINAL CONNECTIONS ON ALL HOODS. VERIFY AND COMPLY WITH ALL APPLICABLE CODES. E. ALL EXHAUST HOOD ASSEMBLIES, DUCTING, COMPONENTS, ETC. SHALL BE UMC TYPE 1 ASSEMBLY, EXCEPT AT WAREWASHING AREAS OR AS OTHERWISE NOTED. VERIFY THAT VENTILATION REQUIREMENTS ARE IN COMPLIANCE WITH LOCAL CODES AND REGULATIONS. F. SUGGESTED MINIMUM VENTILATION REQUIREMENTS: A) KITCHEN AREAS: 45 TO 60 AIR CHANGES /HOUR B) SERVICE AREAS: 45 TO 60 AIR CHANGES/HOUR C) PREP AREAS: 45 TO 60 AIR CHANGES/HOUR D) WASHING AREA: 45 TO 60 AIR CHANGES/HOUR E) STORAGE ROOMS: 3 AIR CHANGES/HOUR F) OFFICES: 4 AIR CHANGES/HOUR G) CONDENSING UNITS: 1000 CFM/HP (AIR-COOLED) 200 CFM/HP (WATER-COOLED) G. PROVIDE DOUBLE -WALLED GAS/VENT FLUE TO THE ATMOSPHERE AS REQUIRED BY LOCAL CODES. ANY FLUE OF EXCESSIVE LENGTH, WITH BENDS OR OTHER RESTRICTIONS MUST BE PROVIDED WITH A BOOSTER EXHAUST FAN INTERWIRED TO OPERATE WITH THE EQUIPMENT BEING VENTED. BOOSTER FAN SHALL PROVIDE 0" S.P. AT CONNECTION TO EQUIPMENT. H. ALL REQUIRED MATERIALS TO MAKE THE FINAL CONNECTIONS TO ALL CONTRACTOR PROVIDED KITCHEN EQUIPMENT. t a g I ai 1 9 7 (rnNITTNI l IF)) GENERAL CONTRACTOR REQUIREMENTS THE ARCHITECT IS RESPONSIBLE FOR SPECIFYING THE FOLLOWING: THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE FOLLOWING UNLESS OTHERWISE NOTED. A. THE IN -WALL REINFORCING OR WALL BACKING FOR ALL WALL MOUNTED, RECESSED OR SEMI -RECESSED EQUIPMENT OR CONTROL PANELS. B. A 4" DEEP DEPRESSION FOR ALL WALK-IN COOLER/FREEZERS, WITH A SMOOTH AND TRANSIT -LEVEL FINISH. THE EXCESS DEPRESSION IS TO BE FILLED WITH GROUT. THE FINISHED FLOOR MATERIALS AND COVED BASES ARE TO BE INSTALLED AFTER THE WALK-IN PANELS HAVE BEEN SET IN PLACE. C. A 6" HIGH SOLID CONCRETE PAD WITH TROWEL -SMOOTH AND LEVEL FINISH. D. AN EASILY VISIBLE PERMANENT BENCHMARK INDICATING FINISHED FLOOR LEVEL. E. ANY FIRE RELATED MATERIALS FOR EXHAUST VENT DUCTS, VENT STACKS, AND ANY HEAT PRODUCING FOOD SERVICE EQUIPMENT. l/GDTGV rnMD1 TANIrG %A/TTw i nrAi rnnGC ANin DCr_i 11 A"rTnNIC V LIx, 1 COMI Ll/1NCE VV111 1 LVI.1mL L.VVLJ rAIMV r\Lt7VL/-111\IIV.J. F. THE COVED BASES AT ALL VERTICAL INTERSECTIONS OF ALL KITCHEN FLOORS. G. ALL CONDUITS FOR REFRIGERATION OR DRINK LINES SHALL HAVE A SMOOTH INTERIOR FINISH, A MINIMUM RADIUS OF 24" AT ALL BENDS AND A MINIMUM 16" X 18" X 12" DEEP ACCESSIBLE PULL BOX ON ALL CONDUIT RUNS IN EXCESS OF 95'-0", IN ALL FLOORS OR CONCEALED SPACES. THE TOTAL OF ALL BENDS BETWEEN PULL BOXES NOT TO EXCEED 1800. STUB CONDUIT ENDS OUT 2" FROM WALLS OR 2" ABOVE FINISHED FLOORS. VERIFY COMPLIANCE WITH ALL LOCAL CODES AND REGULATIONS, H. ALL HOLES OR SLEEVES THROUGH FLOORS, WALLS AND CEILINGS, AS REQUIRED FOR THE INSTALLATION OF REFRIGERATION, DRINK, ELECTRICAL OR PLUMBING LINES AS SHOWN ON THESE PLANS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING HOLES AND SLEEVES AFTER INSTALLATION OF THE LINES. I. ALL PADS OR CURBS FOR FOOD SERVICE EQUIPMENT AND/OR ROOF OR SERVICE AREA MOUNTED COMPRESSOR RACKS. VERIFY COMPLIANCE WITH LOCAL CODES AND REGULATIONS. J. ALL OPENINGS IN WALLS AS INDICATED ON THESE PLANS FOR ANY RECESSED OR SEMI -RECESSED CONTROL PANELS. K. SLOPE ALL FLOORS TO FLOOR SINKS, FLOOR DRAINS OR FLOOR Tpnl i(-.HC VERIFY (-r)MDIT©NrP \A/TTI-I I nrAl rnnPQ • �L tl111 1 LV t.I�L t.V VLJ• L. A MINIMUM OF 150 LBS. PER SQUARE FOOT FLOOR LOADING, OR HIGHER AS REQUIRED BY LOCAL CODES. M. RECOMMENDED FINISHED CEILING HEIGHTS IN KITCHEN AREAS AND FOR SPECIFIC FOOD SERVICE EQUIPMENT ARE AS FOLLOWS: 1) KITCHEN AREAS WITH HOODS: 9'-011 2) COOLER/FREEZER AREAS: 9 1-611 3) GENERAL AREAS: 8'-0" 4) ICE MAC HIKE AKCAS: 9'-U" ADEQUATE SPACE IS NEEDED ABOVE THE FINISHED CEILINGS FOR MECHANICAL AND ELECTRICAL WORK, ESPECIALLY FOR EXHAUST HOOD DUCTING. PLEASE NOTIFY RJS+ASSOCIATES IF HEIGHTS ARE LESS THAN RECOMMENDED MINIMUMS. (E) EXISTING (X) EXISTING TO BE REMOVED (R) RELOCATE NIC NOT IN CONTRACT U.O.N. UNLESS OTHERWISE NOTED FBGC FURNISHED BY GC FF & E FIXTURES FURNISHIINGS AND EQUIPMENT ( + ) ABOVE FINISHED FLOOR DN ( +) DOWN FROM CEILING TO HEIGHT ABOVE ABOVE FINISHED FLOOR CONN CONNECTION G GAS MBTUH 1000 BTU/HR TWR TOWER WATER RETURN TWS TOWER WATER SUPPLY PD PRESSURE DROP CFM CUBIC FEET PER MINUTE FPM FEET PER MINUTE SR STEAM RETURN SS STEAM SUPPLY THE FOLLOWING SYMBOLS MAY BE USED IN THE DRAWINGS: MECHANICAL REFERENCES; z RETURN AIR DIFFUSER ® SUPPLY AIR DIFFUSER )=I SUPPLY AIR LINEAR DIFFUSER ® FLOOR DEPRESSION (REFER TO NOTE C.2) MASONRY PAD (REFER TO NOTE C.3) NON-COMBUSTIBLE WALL MATERIAL (VERIFY REQUIREMENTS WITH LOCAL CODES) FINISHED WALL OPENING WALL BACKING (REFER TO NOTE C. 1) SUPPLY DUCT ® EXHAUST DUCT ® DIRECT CONNECT FLUE (VERIFY REQUIREMENTS WITH LOCAL CODES) ® AIR MOVEMENT/HEAT REMOVAL (VERIFY REQUIREMENTS WITH LOCAL CODES) REFER TO INDICATED NOTE Coo N D U iI T NOTES,-- 1. CONDUIT 00 BE PROVIDED BY GENERAL CONTRACTOR, 2. CONDUIT RUNS ABOVE CEILING MUST HAVE A SMOOTH INTERIOR WITH MINIMUM INSIDE DIMENSION OF SIX INCHES, AND HAVE ONLY ONE (1) 24" MINIMUM RADIUS SWEEP BEND AT EACH END 3. DURING CONSTRUCTION, CONDUIT TO BE FINISHED AT 24"-AFF. TO BE CONSTRUCTED WITH INTERNALLY SMOOTH, LEAK TIGHT JOINTS. 4. CONDUIT TO BE CAPPED AND SEALED AT BOTH ENDS DURING CONSTRUCTION. INSTALLER TO TRIM EXPOSED ENDS. 5. AFTER PRODUCT LINES ARE INSTALLED, THE OPEN ENDS OF THE CONDUIT ARE TO BE FILLED AND SEALED (WATERTIGHT) APPROXIMATELY 2 TO 4 INCHES AT EACH END. BEER SYSTEM CONDUIT SODA SYSTEM CONDUIT CONDUIT SCHEMATIC - ABOVE CEILING DETAIL IS NOT TO SCALE * FOR SCHEMATIC PURPOSE ONLY FIELD VERIFY EXACT LENGTHS & LOCATIONS OF CONDUIT RUNS MINIMUM RADIUS FINISHE CEILING LINE FINISHED FLOOR NOTE: CONDUIT MUST BE A MINIMUM OF 6"-AFF; IN ORDER TO MEET ALL STANDARD HEALTH CODES (VERIFY) CEILING; HEIGHT STATE PROJECT NO. 132-0089 N Phase 2 of 5 O V1 E-I O o C ^ w r�l o C� n RJS + ASSOCIATES !NTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 1 4 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434,3735 vA%w.rjsfsd.com MOSER LCN NT11-11-LS C N ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT MECHANICAL NOTES DATE 11/02/2018 COPYRIGHT Moser Pilon Nelson Architects DVVG. NO. REVISIONS t � i 1 � i 1 1 i--------- t----------, 1 1 i� 13B ii ii 13C li 1 1 / I 1 1 EXHAUST & SUPPLY FANS REFER TO MEP j I DRAWINGS FOR PLACEMENT %A w w w w w w w w w w w w w w w ww, ,��wwwwww�wwrr1 1 1 1 1 1 1 1 21B j 1 1 1 1 1 1 1 1 22B i 1 REMOTE CONDENSORS ; (VERIFY LOCATION) VITA -T EAT 1=nIITPMFNT SCHEDULE I ITEM NO QTY EQUIPMENT CATEGORY BUFFET/CAFETERIA, CASHIER STATION MANUFACTURER MULTITERIA MODEL NUMBER CS36 EQUIPMENT REMARKS - 1 1 1 A 1 ICASHTER MODULE POS BY OWNER SM58N-S 2 1 MILK COOLER BEVERAGE -AIR 3 1 BUFFET/CAFETERIA, COLD FOOD STATION MULTITERIA CLS90 - 3A 1 DROP -IN, COLD WELL MULTITERIA DI-2075TA-T - 4 1 BUFFET/CAFETERIA, HOT FOOD STATION MULTITERIA HLS84 4A 1 DROP -IN, HOT WELLS, TOP -MOUNT MULIIIERIA nnnn=cnnTnnn7ec rivv rr)n- ... 1A 5 1 BUFFET/CAFETERIA, FLAT TOP FABRICATOR ULS24 - 5A 1 ELECTRICAL PANEL CART, CONDIMENT MULTITERIA SUB PANEL REFER TO FS-1.13.1-FS-1.13.3 FOR DETAILS 6 1 LAKESIDE 70640 7 1 ADA WORK TABLE IFABRICATOR STAINLESS STEEL - HS-1D-1-PT 8 1 CABINET, HEATED, PASS-THRU VICTORY 9 1 PREP TABLE W/OVERHEAD SHELF & UTENSIL RACK FABRICATOR STAINLESS STEEL - 9A 4 DRAWER FABRICATOR STAINLESS STEEL - 10 1 SPARE NUMBER 11 1 1 IREFRIGERATOR, PASS-THRU Vi -IUKT RSA_1D_Sl_pT 12 2 HAND SINK, WALL MOUNT ADVANCE TABCO 7-PS-26 12A 2 WASTE RECEPTACLE RUBBERMAID FG254300BLA 28 QUART CAPACITY 12B 2 PAPER TOWEL DISPENSER BY VENDOR BY VENDOR - 12C 2 SOAP DISPENSER BY VENDOR BY VENDOR - ADVANCE TABCO 7-PS-25 WITH K-170 EYE WASH ATTACHMENT 12D 1 HAND SINK, WALL MOUNT 13 1 EXHAUST HOOD HALTON KVE - 13A 1 FIRE SUPRESSION SYSTEM ANSUL R-102 TIE INTO BLDG FIRE ALARM;REFER TO DETAIL SHEET FS-Hl FOR UTILITY INF 13B 1 EXHAUST FAN SUPPLY FAN BY GC BY GC 13C 1 Qv r-r BY GC - - - 13D LOT WALL FLASHING FABRICATOR STAINLESS STEEL - 13E 1 CONTROL PANEL HALTON MARVEL REFER TO FS-1.8.1-FS-1.8.3 FOR MECHANICAL DETAILS 14 1 PREP TABLE FABRICATOR STAINLESS STEEL 15 1 OVEN, CONVECTION, GAS SAFETY SYSTEM MOVEABLE GAS CONNECTOR STEAMER, CONVECTION, GAS BLODGETT DFG-100 - 15A 1 DORMONT MANUFACTURING 1675KMS48PS 16 1 MARKET FORGE 350OM36G WITH FILTER 16A 1 SAFETY SYSTEM MOVEABLE GAS CONNECTOR DORMONT MANUFACTURING 1675KIT2S48PS 17 1 RACK, PAN NEW AGE INDUSTRIAL 1331 - 18 1 PREP TABLE FABRICATOR STAINLESS STEEL - 19 1 PREP TABLE W/ DOUBLE SINK FABRICATOR STAINLESS STEEL - 19A 1 FAUCET, BACKSPLASH MOUNT T & S BRASS B-0230 - 19B 1 ISHELF, WALL MOUNT FABRICATOR STAINLESS STEEL - 20 1 SPARE NUMBER 21 1 WALK-IN COOLER AMERICAN PANEL CUSTOM - 21A 1 I EVAPORATOR, COOLER AMERICAN PANEL SM076 - 21B 1 CONDENSING UNIT, FREEZER AMERICAN PANEL F3AF-0106-CAV-020 22 1 WALK-IN FEEZER AMERICAN PANEL CUSTOM REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 22A 1 I FREEZER, EVAPORATOR COIL AMERICAN PANEL SME065 22B 1 CONDENSING UNIT AMERICAN PANEL AVA2510ZXTXC(2C2117-1) REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 23 2 SHELVING 48" X 24" METRO MAX 5X557GX3 23A 2 SHELVING 42" X 24" METRO MAX 5X547GX3 - 24 2 SHELVING 30" X 24" FABRICATOR MX2430G PROVIDE EACH UNIT WITH 4 SHELVES & 4 POSTS 25 2 SHELVING 48" X 18" METRO MAX 5X357GX3 PROVIDE EACH UNIT WITH 4 SHELVES & 4 POSTS 25A 2 SHELVING 42" X 18" METRO MAX 5X347GX3 PROVIDE EACH UNIT WITH 4 SHELVES & 4 POSTS 26 1 SHELVING 60" X 18" FABRICATOR 5X367GX3 PROVIDE EACH UNIT WITH 4 SHELVES & 4 POSTS 27 1 SINK, NSF, 3 COMP, 18 GAUGE FABRICATOR STAINLESS STEEL - 27A 2 FAUCET, WALL MOUNT T & S BRASS B-1128 27B 1 SHELF, WALL MOUNT W/POT RACK FABRICATOR STAINLESS STEEL - 28 5 SHELVING 42" X 18" MOD A FLEX MX1842GR PROVIDE EACH UNIT WITH 4 SHELVES & HARDWARE 29 1 SHELVING 36" X 24" MOD A FLEX MX1836GR PROVIDE EACH UNIT WITH 4 SHELVES & HARDWARE .n E Z U N O ^L n Z LL r> KITCHEN FOODSERVICE EQUIPMENT PLAN & SCHEDULE HEALTH DEPT. NOTES 1, ALL FOOD SERVICE EQUIPMENT, FABRICATED ITEMS, AND THEIR INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION (N.S.F.) REQUIREMENTS. 2, ALL STATIONARY EQUIPMENT AND FIXTURES TO BE SEALED TO THE WALL OR ADJACENT EQUIPMENT. USE ALUMINUM COLOR AT STAINLESS STEEL AND CLEAR AT ALL OTHERS. 3. ALL SINKS IN THE FOOD FACILITY MUST BE PROVIDED WITH HOT WATER (MIN. 110 DEG. F.) AND COLD RUNNING WATER UNDER PRESSURE AND WILL HAVE A PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MINIMUM OF 10 SECONDS. 4. A HAND SINK IS PROVIDED IN EACH FOOD PREPARATION AREA WITH SINGLE SERVICE TOWEL AND SOAP DISPENSER. 5. 3-COMPARTMENT SINKS ARE PROVIDED WITH MIXING VALVE FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. 6. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD PREPARATION, PACKAGING, AND PROCESSING AREAS AND WHERE UTENSILS 7. A MIN. OF 10 FOOT CANDLES (108 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD AND UTENSIL STORAGE ROOMS, TOILET, AND DRESSING ROOMS. 8. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL AREAS DURING GENERAL CLEANUP ACTIVITIES. 9. ALL SHELVING OVER WET AREAS (SINKS, MOP SINKS, ETC.) WILL BE STAINLESS STEEL. 10. SHATTER SHIELDS OR SHATTERPROOF LIGHT BULBS TO BE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE AREAS. 11. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 12. FLOOR SINKS UNDER EQUIPMENT MUST BE 50% EXPOSED AND EASILY ACCESSIBLE FOR CLEANING AND SERVICING. 13. ALL EXHAUST HOODS TO BE A MIN. 22 GA. STAINLESS STEEL, U.L. LISTED, AND CONSTRUCTED AND INSTALLED TO ALL U.L. AND CSCB 101.1.1, & CSFC 609.1 SPECIFICATIONS. EXHAUST DUCTS TO BE A MIN. 16 GA. STEEL. (TYPE 1 HOOD DUCTS TO HAVE WELDED SEAMS) 14. ALL FLOOR TILE TO BE SMOOTH UNDER ALL EQUIPMENT, AND WALKWAYS TO HAVE A LIGHT TEXTURE ONLY. 1.5_ ALL 3-COMPARTMENT SINKS TO HAVE A MIN. COMPARTMENT SIZE OF 18" X 18" X 12" DEEP, WITH A MIN. 18" DRAIN BOARD ON EACH END. PROVIDE WITH 8" HIGH INTEGRAL BACK SPLASH AT ALL WALLS. (SEE FOOD SERVICE SPECIFICATIONS FOR SIZES OF EACH ITEM.) 16. SUPPORT ROOMS ARE FOR STORAGE AND UTENSIL WASHING ONLY. NO VEGETABLE WASHING OR FOOD PREP. TO BE DONE FOOD SERVICE NOTES 1. REQUIREMENTS SHOWN ARE FOR ONE ITEM, TO DERIVE TOTAL MULTIPLY BY QUANTITY SHOWN. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE MAG. STARTERS. DISCONNECT SWITCHES, INTERLOCKS AND THERMO-OVERLOAD PROTECTION WHERE REQUIRED. 3. PLUMBING CONTRACTOR SHALL PROVIDE STOP VALVES AHEAD OF ALL OPERATING HANDLES AND FAUCETS. 4. SEE EQUIPMENT PLUMBING AND ELECTRICAL ROUGH -IN DRAWINGS FOR ADDITIONAL INFORMATION. 5. ELECTRICAL POWER TO COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED THRU A SHUNT -TRIP SYSTEM FOR FIRE FUEL SHUT-OFF. ELECTRICAL CONTRACTOR SHALL WIRE CONTROL CIRCUIT TO MICRO SWITCH PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR ON HOOD FIRE PROTECTION SYSTEM. 6. GAS SUPPLY TO ALL COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED WITH AN ELECTRIC VALVE FOR FIRE -FUEL SHUT-OFF. VALVE TO BE SUPPLIED BY THE "K.E.C." AND INSTALLED BY THE "P.C." K.E.C. SHALL CONNECT VALVE TO THE HOOD FIRE PROTECTION SYSTEM FOR AUTOMATIC SHUT-OFF. 7. ALL WALK-IN BOX COILS REQUIRE CONNECTIONS TO SOLENOID VALVE, I -SIAI, -I -CLOCK AND MOTORS AND CONTROL WIRING TO THE REMOTE COMPRESSOR ALL CONNECTIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 8. ALL WALK-IN BOX FIXTURES TO BE PROVIDED BY THE "K.E.C." INSTALLATION AND WIRING TO BE PROVIDED BY THE "E.C." WITH ALL CONDUIT RUN ON EXTERIOR (TOP) OF BOX. 9, VACUUM BREAKERS WHEN USED, TO BE MINIMUM OF SIX INCHES ABOVE THE FLOOD LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 10. WALL BACKING PROVIDED BY GENERAL CONTRACTOR. 11 • PLUMBING CONTRACTOR TO SUPPLY GREASE TRAP AS REQUIRED BY CODE. 12. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER ON CASTERS WITH FLEXIBLE UTILITY QUICK DISCONNECTS OR FIXED ON S/S LEGS. 13. ALL NEW EXHAUST HOODS WILL BE CONSTRUCTED TO MEET THE FOLLOWING STANDARDS: NSF, UL AND NFPA-96. ALL NEW HOODS TO BEAR UL CLASSIFIED LABEL WITHOUT DAMPERS IN EXHAUST VENT COLLARS. HOODS ARE DESIGNED TO MEET OR EXCEED 50 FPM CAPTURE VELOCITY AT THE COOKING SURFACE EDGE AND HAVE A 6" MIN. OVERHANG AT ALL EXPOSED COOKING AREAS. 14. BACK SPLASHES OF EQUIPMENT SHALL BE SEALED TO WALLS WITH CLEAR SILICONE CAULK IN A NEAT WORKMAN LIKE MANNER. SHEET NOTES This plan represents a food service layout of culinary, beverage, systems and related equipment for the convenience of owner/operator, architects, mechanical, electrical, and plumbing engineers, contractors, kitchen equipment fabricators, KI`L( hen egUIPI I Ieilt WIILI a�iOrS a'iid other related trades. The base plan has been made available from information provided by others, not limited to measurements, electronic backgrounds, grid lines and existing or proposed building systems, not limited to (olumbina, structural, concrete, ductwork, electrical and mechanical). General contractors, subcontractors, kitchen equipment dealers, contractors, installers, related and non -related contractors, are responsible for securing and obtaining their own measurements and specific information. Information indicated on these plans are generally for food service equipment and are Intenaea as reference only. RJS Associates is not responsible for the engineering or integration of related engineering and disciplines throughout the full set of construction documents specific to the food service equipment in relation to the structural, architectural, mechanical, plumbing and electrical trades, unless otherwise specifically provided for in the plans and specifications. RIS Associates assumes no responsibility for work done by any and all architects, engineers, consultants or contractors, or for any changes made necessary by local, state, or national building codes, ordinances, structural conditions, or by the substitution or changes in equipment shown on this plan(s). Contractors are to make allowances for internal and external final connections on the food service equipment, waste piping, valves, back -flow prevention, traps, drain grates, fluid /gas regulators, faucets, steam traps, starting switches and motors, except where specifically noted in the food service specifications, section 11400. These plans, designs, notes, details and specifications herein are the exclusive property of RIS Associates and may not be reproduced or used by anyone, either in part or in their entirety, without first securing written permission by R3S Associates. The unauthorized reproduction, copying, or use of this drawing / plan(s) or j electronic file or disc containing information specific to this project without the expressed written consent of RIS Associates is prohibited and any infringement will be subject to any and all remedies available to RJS Associates under the Copyright Laws of the United States. CONFORMED SET MARCH 22, 2019 0 2-19-2019 BID SUPPLEMENT I ® 2-22-2019 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N Phase 2 of 5 V1 ►� Wp!A V1 O ``,`\S�t1511 if if!)t�I 1111 lt0l RIS + ASSOCIATES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860.434,2700 F: 860.434.3735 w 4.rjsMxom MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT EQUIPMENT PLAN & SCHEDULE DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. SCALE: 1/4"=1'-0" FS=11*1 KITCHEN LOW VOLTAGE SCHEDULE J U ITE(9 M W H V)J cn Q 0 Z LL ELEC NO QTY EQUIPMENT CATEGORY a o O n=- U ¢ LU w Q REMARKS IA I 1 CASHIER MODULE I X 120 1 60 4.0 5-15P UP 1PROVIDE CONDUIT FOR DATA LINE;POWER SUPPLIED BY ITEM #5A, ELECTRICAL PANEL 1 E 1 1 21B :a 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KITCHEN ELECTRICAL ROUGH -IN SCHEDULE ITEM NO QTY EQUIPMENT CATEGORY a- b n o O > w = a LU iJ j Q Y a = w Z �v uj u- w¢ ELEC REMARKS lA 1 ICASHIER MODULE X 120 1 60 4.0 - 5-15P UP PROVIDE CONDUIT FOR DATA LINE 2 1 MILK COOLER X 115 1 60 7.5 1/3 5-15P POWER PROVIDED BY ITEM 5A, ELECTRICAL PANEL 3 1 BUFFET/CAFETERIA, COLD FOOD STATION X 120 1 60 7.0 - 1/4 5-15P POWER PROVIDED BY ITEM 5A, ELECTRICAL PANEL 3A 1 DROP -IN, COLD WELL X 120 1 60 12.0 1/2 5-15P - POWER PROVIDED BY ITEM 5A, ELECTRICAL PANEL 4 1 BUFFET/CAFETERIA, HOT FOOD STATION X 208 1 60 29.8 6.2 - 6-50P POWER PROVIDED BY ITEM 5A, ELECTRICAL PANEL 4A 1 DROP -IN, HOT WELLS, TOP -MOUNT - X 208/240 3 60 29.8 6.2 - - POWER PROVIDED BY ITEM 5A, ELECTRICAL PANEL 5A 1 ELECTRICAL PANEL - X 120/208 1 60 120.0 - UP REFER TO FS-1.13.1-FS-1.13.3 FOR MECH. DETAILS; SUPPLIES POWER TO #1, 1A, 2, 3, 3A, 4, & 4A 8 1 CABINET, HEATED, PASS-THRU X - 208/240 1 60 6.3 - - 6-20P DN - 11 1 REFRIGERATOR, PASS-THRU X - 120 1 1 60 9.8 - - 5-15P DN - 13 1 EXHAUST HOOD - X 120 1 1 60 15.0 DN - 13A 1 FIRE SUPRESSION SYSTEM - X 120 1 - 20.0 DN - 13E 1 CONTROL PANEL - X 120 1 - 15.0 - 60 - 15 1 OVEN, CONVECTION, GAS " X 115 1 60 6.0 0.9 24 - 16 1 STEAMER, CONVECTION, GAS X - 120 1 60 6.0 - - 5-15P 24 - 21 1 WALK-IN COOLER - X 115 1 60 3-1/2 REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 21A 1 EVAPORATOR, COOLER - X 1 208/230 1 60 1.0 - - REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 21B 1 CONDENSING UNIT, FREEZER - X 208/230 3 60 12.7 - - - - REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 22 1 WALK-IN FEEZER - X 115 1 60 3.5 REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 22A 1 1 FREEZER, EVAPORATOR COIL - X 208/230 13 1 60 1.4/9.1 - - - REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS 22B 1 CONDENSING UNIT - X 208/230 3 1 60 13.7 - REFER TO FS-1.9.1-FS-1.9.3 FOR MECHANICAL DETAILS a� E Z U N 0 L D- Z GAS VALVE SIZING, TYPE AND LOCATION BY MECHANICAL ENGINEER GAS VALVE SUPPLIED BY KEC INSTALLED BY PLUMBER GAS VALVE DETAIL N.T.S. WATER CUT OFF PROBE MOUNTED ON BAIN MARIE SIDE 1/2" 0 HOLE REQUIRE PROBE MOUNTED BY K.E.C. CONNECTED TO HEATER BY E.C. BAIN MARIE MAUTO FILL N.T.S. pi nq II 1, m lii �i m m mri m r, GFCI m �o0p°°� m STAINLESS STEEL PLATE DIST. A.F.F. FOOD SERVICE RECEPTACLE MOUNT RECEPTACLES HORIZONTALLY IN FOOD SERVICE AREAS NOTE: 1. FOODSERVICE OUTLETS SHOWN AS A SUGGESTED MINIMUM. ELECTRICAL ENGINEER IS RESPONSIBLE FOR SPECIFIYING CONVENIENCE OUTLET LOCATION & SIZING AS REQUIRED BY LOCAL CODES AND REGULATIONS 0 j D i o UTILITY STUB UP FROM BELOW SEE SHEET FS-1.7.2 FOR LOCATION i 1 I 0 __ 0 ---------------- --- I I 4'-10" 7-8" (E:4) _ E E '` E E`. E 22 22A z'1 21A CONV. CONY. i 1 V V 10'-10" ti - CONV.- --- CONV. , 7. UTILITY STUB 1 _ - - - - - - UTILITY STUB UP UP (E,IA)Q- _ FROM BELOW FROM BELOW , 3� -� _ - 1S J -� I FOR LOCATION �___-� SEE -1.7.2SHEET _ d SEE SHEET FS-1.7.2 -~ �o FS 1.7.2 I ;; n T -1 - 1 -! _ ! _ o _ _._ . _-T _� FOR (E3) _- 1 I LOCATION I f _ L_J L__ _-J L_ U _ _ E! I � I CO PV. ° I E 00 --- IIIIIIIIIIII ---- �IIIIII�IIII------,- ===r�� a UP (E:3A) I • -- i I E - �J I ; I I I 16 ILL I ^I I I II UTILITY STUB UP-- • 0 0 - - -E o 5A - 8'-5" -14'-10" I I LINI FROM BELOW SEE SHEET FS-1.7.2 FOR LOCATION , u -,b1 I I II oil �14� I ���M! i ��i �-�� •� CONY. �-� �r _1_JI lip I (E2) I I �- - E KITCHEN FOODSERVICE EQUIPMENT ELECTRICAL ROUGH -IN & LOW VOLTAGE PLAN & SCHEDULES SCALE: 1/4"= V-0" ELECTRICAL LEGEND SYMBOLS ABBREVIATIONS OJUNCTION BOX (3-BOX) A AMPERES ❑ EQUIPMENT INTERCONNECTION BY E.C. AFF ABOVE FINISHED FLOOR ELECTRICAL ROUGH -IN BTC BRANCH TO CONNECTION POINT AND CONNECT EQUIPMENT SINGLE ELECTRICAL OUTLET(SCO) CONV. CONVENIENCE OUTLET 120V 1PH 2O.OA DUPLEX ELECTRICAL OUTLET (DCO) D.C. DIRECT CONNECTION FOUR PLEX ELECTRICAL OUTLET (QCO) DN DOWN FROM ABOVE O STUB UP FROM FIN FLOOR (TERMINATED CONDUIT) E.C. ELECTRICAL CONTRACTOR ' TELEPHONE OUTLET HP HORSE POWER ODATA LINE CONNECTION K.E.C. KITCHEN EQUIPMENT CONTRACTOR BREAKER PANELBOARD KW KILOWATTS SWITCH AS NOTED PH PHASE FLOOR BOX (FL. BOX) U.C. UNDER COUNTER V VOLTS W WATTS TE RIA HEALTH DEPT. NOTES REVISIONS CONFORMED SET MARCH 22, 2019 1. ALL FOOD SERVICE EQUIPMENT, FABRICATED ITEMS, AND THEIR 2-19-2019 BID SUPPLEMENT 1 ® INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION 2-22-2019 BID SUPPLEMENT 2 (N.S.F.) REQUIREMENTS. 2. ALL STATIONARY EQUIPMENT AND FIXTURES TO BE SEALED TO THE WALL OR ADJACENT EQUIPMENT. USE ALUMINUM COLOR AT STAINLESS STEEL AND CLEAR AT ALL OTHERS. 3. ALL SINKS IN THE FOOD FACILITY MUST BE PROVIDED WITH HOT WATER (MIN. 110 DEG. F.) AND COLD RUNNING WATER UNDER PRESSURE AND WILL HAVE A PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MINIMUM OF 10 SECONDS. 4. A HAND SINK IS PROVIDED IN EACH FOOD PREPARATION AREA WITH SINGLE SERVICE TOWEL AND SOAP DISPENSER. 5. 3-COMPARTMENT SINKS ARE PROVIDED WITH MIXING VALVE FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. 6. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD PREPARATION, PACKAGING, AND PROCESSING AREAS AND WHERE UTENSILS 7. A MIN. OF 10 FOOT CANDLES (108 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD AND UTENSIL STORAGE ROOMS, TOILET, AND DRESSING ROOMS. STATE PROJECT NO. 8. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL AREAS DURING GENERAL CLEANUP ACTIVITIES. 132-0089 N 9. ALL SHELVING OVER WET AREAS (SINKS, MOP SINKS, ETC.) WILL BE STAINLESS Phase 2 5 STEEL. Of 10. SHATTER SHIELDS OR SHATTERPROOF LIGHT BULBS TO BE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE AREAS. 11. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 12. FLOOR SINKS UNDER EQUIPMENT MUST BE 50% EXPOSED AND EASILY ACCESSIBLE FOR CLEANING AND SERVICING. 13. ALL EXHAUST HOODS TO BE A MIN. 22 GA. STAINLESS STEEL, U.L. LISTED, AND CONSTRUCTED AND INSTALLED TO ALL U.L. AND CSCB 101.1.1, & CSFC 609.1 SPECIFICATIONS. EXHAUST DUCTS TO BE A MIN. 16 GA. STEEL. (TYPE O 1 HOOD DUCTS TO HAVE WELDED SEAMS) 14. ALL FLOOR TILE TO BE SMOOTH UNDER ALL EQUIPMENT, AND O WALKWAYS TO HAVE A LIGHT TEXTURE ONLY. 15. ALL 3-COMPARTMENT SINKS TO HAVE A MIN. COMPARTMENT SIZE OF 18" X 18" X 12" DEEP, WITH A MIN. 18" DRAIN BOARD ON EACH END. PROVIDE WITH 8" HIGH INTEGRAL BACK SPLASH AT ALL WALLS. (SEE FOOD SERVICE SPECIFICATIONS FOR SIZES OF EACH ITEM.) 16. SUPPORT ROOMS ARE FOR STORAGE AND UTENSIL WASHING ' w V ) ONLY. NO VEGETABLE WASHING OR FOOD PREP. TO BE DONE I� o � Q FOOD SERVICE NOTES w Wa O 1. REQUIREMENTS SHOWN ARE FOR ONE ITEM, TO DERIVE TOTAL MULTIPLY BY QUANTITY SHOWN. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE MAG. STARTERS. DISCONNECT SWITCHES, INTERLOCKS AND THERMO-OVERLOAD w PROTECTION WHERE REQUIRED. 3. PLUMBING CONTRACTOR SHALL PROVIDE STOP VALVES AHEAD OF ALL OPERATING HANDLES AND FAUCETS. w 4. SEE EQUIPMENT PLUMBING AND ELECTRICAL ROUGH -IN DRAWINGS O r FOR ADDITIONAL INFORMATION. �•rj 5. ELECTRICAL POWER TO COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED THRU A SHUNT -TRIP SYSTEM FOR FIRE FUEL SHUT-OFF. ELECTRICAL CONTRACTOR SHALL WIRE CONTROL O *00 CIRCUIT TO MICRO SWITCH PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR ON HOOD FIRE PROTECTION SYSTEM. O 6. GAS SUPPLY TO ALL COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED WITH AN ELECTRIC VALVE FOR FIRE -FUEL SHUT-OFF. VALVE TO BE SUPPLIED BY THE "K.E.C." AND �1 INSTALLED BY THE "P.C." K.E.C. SHALL CONNECT VALVE TO THE HOOD FIRE PROTECTION SYSTEM FOR AUTOMATIC SHUT-OFF. • 7. ALL WALK-IN BOX COILS REQUIRE CONNECTIONS TO SOLENOID VALVE, T-STAT, T-CLOCK AND MOTORS AND CONTROL WIRING TO THE REMOTE COMPRESSOR ALL CONNECTIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 8. ALL WALK-IN BOX FIXTURES TO BE PROVIDED BY THE "K.E.C." INSTALLATION AND WIRING TO BE PROVIDED BY THE "E.C." WITH ALL CONDUIT RUN ON EXTERIOR (TOP) OF BOX. 9. VACUUM BREAKERS WHEN USED, TO BE MINIMUM OF SIX INCHES ABOVE THE FLOOD LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 10. WALL BACKING PROVIDED BY GENERAL CONTRACTOR. 11. PLUMBING CONTRACTOR TO SUPPLY GREASE TRAP AS REQUIRED BY CODE. 12. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER ON CASTERS WITH FLEXIBLE UTILITY QUICK DISCONNECTS OR FIXED ON S/S LEGS. 13. ALL NEW EXHAUST HOODS WILL BE CONSTRUCTED TO MEET THE FOLLOWING STANDARDS: NSF, UL AND NFPA-96. ALL NEW HOODS TO BEAR UL CLASSIFIED LABEL WITHOUT DAMPERS IN EXHAUST VENT COLLARS. HOODS ARE DESIGNED TO MEET OR EXCEED 50 FPM CAPTURE VELOCITY AT THE COOKING SURFACE EDGE AND HAVE A 6" MIN. OVERHANG AT ALL EXPOSED COOKING AREAS. 14. BACK SPLASHES OF EQUIPMENT SHALL BE SEALED TO WALLS WITH CLEAR SILICONE CAULK IN A NEAT WORKMAN LIKE MANNER. `,�1t1t1Ntflf►pff�`f n SHEET NOTES ; This plan represents a food service layout of culinary, ljeftlTtl��;;:� beverage, systems and related equipment for the convenience of owner/operator, architects, mechanical, electrical, and plumbing engineers, contractors, kitchen equipment fabricators, kitchen equipment contractors and other related trades. The base plan has been made available from information provided by others, not limited to measurements, electronic backgrounds, grid lines and existing or proposed building systems, not limited to RIS + ASSOCIATES (plumbing, structural, concrete, ductwork, electrical and mechanical). General contractors, subcontractors, INTEGRATED FOOD SERVICE DESIGN kitchen equipment dealers, contractors, installers, related P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 and non -related contractors, are responsible for securing T: 80.434.2700 F: 860.434.3735 and obtaining their own measurements and specific information. Information indicated on these plans are generally for food service equipment and are intended as reference only. RJS Associates is not responsible for the engineering or integration of related engineering and disciplines throughout the full set of construction documents specific to the food service equipment in relation to the structural, architectural, mechanical, /(O C�� M S plumbing and electrical trades, unless otherwise specifically provided for in the plans and specifications. RJS Associates assumes no responsibility for work done PILON by any and all architects, engineers, consultants or contractors, or for any changes made necessary by local, NELSON state, or national building codes, ordinances, structural conditions, or by the substitution or changes in A R C H I T E C T S equipment shown on this plan(s). Contractors are to make allowances for internal and external final 30 J O R D A N LANE connections on the food service equipment, waste piping, W E T H E R S F I E L D, CT. 06109 valves, back -flow prevention, traps, drain grates, fluid (860) 563-6164 /gas regulators, faucets, steam traps, starting switches and motors, except where specifically noted in the food service specifications, section 11400. TITLE FOOD SERVICE EQUIPMENT ELECTRICAL ROUGH -IN & LOW VOLTAGE These plans, designs, notes, details and specifications PLAN & herein are the exclusive property of RJS Associates and may not be reproduced or used by anyone, either in part SCHEDULES or in their entirety, without first securing written permission by RJS Associates. The unauthorized reproduction, copying, or use of this drawing / plan(s) or DATE 11/02/2018 electronic file or disc containing information specific to this project without the expressed written consent of RJS COPYRIGHT Associates is prohibited and any infringement will be Moser Pilon Nelson Architects subject to any and all remedies available to RJS Associates under the Copyright Laws of the United States. DWG. NO. FS=1.3.1 NOTE: 1. FOODSERVICE FLOOR DRAINS SHOWN AS A SUGGESTED MINIMUM. PLUMBING ENGINEER IS RESPONSIBLE FOR SPECIFIYING CONVENIENCE DRAIN LOCATION & SIZING AS REQUIRED BY LOCAL CODES AND REGULATIONS. FLOOR SINKS DIMENSIONED ON SHEET FS-1.7.2 KITCHEN PLUMBING ROUGH - IN SCHEDULE 0-1 Ce- fy- oC ~Q 0- :D � U 0Z H,. IW>- tW>>- Q-� �Z �Z cU) �w �WW bIli- bZ Z Z ITEM �Z ON > Oa iZ OtLU �i ON OL�i =Q =a W O �M L- a'~ o.WN- ¢� = m H QL�i PLUMBING NO QTY EQUIPMENT CATEGORY = Ln = (D _ ¢ v cn v a v v o o cn o ¢ Z cn U� cn U7 ¢ REMARKS 3A 1 DROP -IN, COLD WELL - - - - - - 3/4 - 4A 1 DROP -IN, HOT WELLS, TOP -MOUNT - 1/4 UP -- 12 2 HAND SINK, WALL MOUNT 1/2 - 18 1/2 18 - 1-1/2 20 - - - 12D 1 HAND SINK, WALL MOUNT 1/2 - 18 1/2 18 - - 1-1/2 20 - - - WITH K-170 EYE WASH ATTACHMENT - - - - - - - - REFER TO FS-1.8.1-FS-1.8.3 FOR MECHANICAL DETAILS 13E 1 CONTROL PANEL 15 1 OVEN, CONVECTION, GAS - - - - - - 3/4 55 30 - 16 1 STEAMER, CONVECTION, GAS 3/8 - 18 3/8 18 - 2 3/4 200 30 - 19 1 PREP TABLE W/ DOUBLE SINK- 19A 1 FAUCET, BACKSPLASH MOUNT 1/2 40 1/2 40 - - - 21A 1 EVAPORATOR, COOLER - - - - - 3/4 - - 22A 1 FREEZER, EVAPORATOR COIL - - - 3/4 " 27 1 SINK, NSF, 3 COMP, 18 GAUGE- 27A 2 1 FAUCET, WALL MOUNT (2)1/2 40 (2)1/2 40 - SUGGESTED PLUMBING 34" WASTE SUPPLY T- 20" 12" 1 HAND SINK, CONNECTIONS DETAIL N.T.S. SEE EQUIPMENT SCHEDULE FOR I.W. SIZE PROVIDE A MINIMUM AIR GAP OF 1" OR MORE AS MAY BE REQUIRED BY LOCAL CODES PLUMBING CONTRACTOR SHALL CONNECT TO OUTLET OF THREADED WASTE OR TAILPIECE FURNISHED WITH KITCHEN EQUIPMENT. INDIRECT WASTE LINES SHALL BE APPROVED PVC TYPE WITH LONG TURN PATTERN FITTINGS. PITCH ALL HORIZONTAL RUNS MINIMUM OF 1/2" PER FOOT WHEN POSSIBLE. PROVIDE CLEANOUTS WHEN REQUIRED BY CODES. PROVIDE RUNNING OR T" TRAPS WHEN REQUIRED BY LOCAL CODES. rNICKLE BRONZE, LOOSE SET GRATE FINISHED FLOOR SEDIMENT BUCKET PORCELAIN INTERIOR FLOOR SINK BY DOME STRAINER PLUMBER SEE PLUMBING FIXTURE SEE PLUMBING SCHEDULE DRAWINGS FOR WASTE SIZE NOTE: PROVIDE NICKLE BRONZE FUNNEL IN �-J APPLICATIONS OF MULTIPLE LINES OR HIGH VOLUME FLOW RATES, WHERE SPACE ALLOWS z FLOOR SINK DETAIL s-1.4. N.T.S. ....................................................... uwit Hit mg mmmligllluulgui unummi a 111t i I �II�Ul�nnn�u�lm nu> Iiu i wi uuqulnmiu�I>tultmluu I o I�, 1"I111 I f„y u� I I I �"M`, IT " ril Tr m IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIfI11Nl III tII11111111I11NIINIIINIIInnnn;R11 ;;;;;;;;;;;;;;;IINIIII - IIIII Illulll innnuunuum w; I= CASTER -MOUNTED RANGE, 6-BURNER WITH DOUBLE SWIVEL FITTING NOTE: STUB OUT GAS SHUT OFFI� VALVE AT 30" t5"AFF ►Y t !*11 ��.. t I0104 '� ®® 1 3 DISCONNECT GAS HOSE DETAIL 5-1.4. N.T.S. PLUMBING GENERAL NOTES 1. PLUMBING ENGINEER IS RESPONSIBLE FOR SPECIFYING CONVENIENCE AND FLOOR DRAIN LOCATION AND SIZING AS REQUIRED BY LOCAL CODES AND REGULATIONS. 2. SEE EQUIPMENT PLAN AND SCHEDULE FOR ADDITIONAL INFORMATION. 3. P.C. TO PROVIDE ALL ROUGH -IN AND FINAL CONNELiIIONS T 0 ALL EQUIPMENT SHOWN HEREIN. 4. SOLID & THICK LINE DOTS REPRESENTS ROUGH -IN LOCATION. a (FURNISHED BY P.C.) / DOTTED LINE REPRESENTS FINAL CONNECTION. 1 / (FURNISHED BY P.C.) a CIRCLE REPRESENTS CONNECTION TO EQUIPMENT. (FURNISHED BY P.C.) 5. PLUMBING CONTRACTOR (P.C.) TO KEEP ALL PLUMBING LINES CLEAR OF WALLBACKING AREAS. 6. P.C. TO PROVIDE AND INSTALL REGULATORS AS REQUIRED. 7. P.C. TO VERIFY PLUMBING REQUIREMENTS AND LOCATIONS FOR EQUIPMENT SUPPLIED GC. 0 Mr 0 o I o \ II ih \\L AL P------ ----- - - ----------sl I I \�� 12 DW IW P IW Go 1.LITY STUB i� i9 .. SEE SHEET FS-: FOR LOCATION - -�_ =__ -9 IW IW 22A = _ - 21A - -- w IP. Iso IPo - I L --- � i - r- 1 r �-r- -- 0 - zn_08o - I - b-----� =------------- - - - I - -+--------------------- L._.Ell16 P IW _ 16 16 G !I i --µa --�I 15 I I - i BUST s4� I. FFICE , I I 13r+ Vd 3HU - J -34 ----- I 2 L_ oIF o/ MANAGE ' °2 5'-9" 4" 4" 1 KITC H E KITCHEN FOODSERVICE EQUIPMENT PLUMBING ROUGH -IN PLAN & SCHEDULE PLUMBING LEGEND SYMBOLS ABBREVIATIONS • HOT WATER AFF ABOVE FINISHED FLOOR O COLD WATER BTC BRANCH TO CONNECT 0 DRAIN CONNECTION CW COLD WATER 0 DIRECT DRAIN DN DOWN FROM ABOVE O WATER CONNECTION DR DRAIN ® FLOOR SINK -GRATE FD FLOOR DRAIN ® FLOOR DRAIN AS NOTED FS FLOOR SINK FUNNEL DRAIN AS NOTED FT FLOOR TROUGH GAS LINE GPH GALLONS PER HOUR ® GAS CONNECTION GPM GALLONS PER MINUTE ® CHILLED WATER HD HUB DRAIN FLEX CONNECT HOSE HW HOT WATER ----- INDIRECT WASTE LINE P PLUMBING PLUMBING INTERCONNECTION PSI POUNDS PER SQUARE INCH 0 STUB UP FROM FIN FLOOR DW DIRECT WASTE IW INDIRECT WASTE CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN CORRIDOR :TERIA HEALTH DEPT. NOTES 1. ALL FOOD SERVICE EQUIPMENT, FABRICATED ITEMS, AND THEIR INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION (N.S.F.) REQUIREMENTS. 2, ALL STATIONARY EQUIPMENT AND FIXTURES TO BE SEALED TO THE WALL OR ADJACENT EQUIPMENT. USE ALUMINUM COLOR AT STAINLESS STEEL AND CLEAR AT ALL OTHERS. 3. ALL SINKS IN THE FOOD FACILITY MUST BE PROVIDED WITH HOT WATER (MIN. 110 DEG. F.) AND COLD RUNNING WATER UNDER PRESSURE AND WILL HAVE A PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MINIMUM OF 10 SECONDS. 4. A HAND SINK IS PROVIDED IN EACH FOOD PREPARATION AREA WITH SINGLE SERVICE TOWEL AND SOAP DISPENSER. 5. 3-COMPARTMENT SINKS ARE PROVIDED WITH MIXING VALVE FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. 6. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD PREPARATION, PACKAGING, AND PROCESSING AREAS AND WHERE UTENSILS 7. A MIN. OF 10 FOOT CANDLES (108 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD AND UTENSIL STORAGE ROOMS, TOILET, AND DRESSING ROOMS. 8. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 3U' OFF THE FLOOR TO BE PROVIDED IN ALL AREAS DURING GENERAL CLEANUP ACTIVITIES. 9. ALL SHELVING OVER WET AREAS (SINKS, MOP SINKS, ETC.) WILL BE STAINLESS STEEL. 10. SHATTER SHIELDS OR SHATTERPROOF LIGHT BULBS TO BE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE AREAS. 11. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 12. FLOOR SINKS UNDER EQUIPMENT MUST BE 50% EXPOSED AND EASILY ACCESSIBLE FOR CLEANING AND SERVICING. 13. ALL EXHAUST HOODS TO BE A MIN. 22 GA. STAINLESS STEEL, U.L. LISTED, AND CONSTRUCTED AND INSTALLED TO ALL U.L. AND CSCB 101.1.1, & CSFC 609.1 SPECIFICATIONS. EXHAUST DUCTS TO BE A MIN. 16 GA. STEEL. (TYPE 1 HOOD DUCTS TO HAVE WELDED SEAMS) 14. ALL FLOOR TILE TO BE SMOOTH UNDER ALL EQUIPMENT, AND WALKWAYS TO HAVE A LIGHT TEXTURE ONLY. 15. ALL 3-COMPARTMENT SINKS TO HAVE A MIN. COMPARTMENT SIZE OF 18" X 18" X 12" DEEP, WITH A MIN. 18" DRAIN BOARD ON EACH END. PROVIDE WITH 8" HIGH INTEGRAL BACK SPLASH AT ALL WALLS. (SEE FOOD SERVICE SPECIFICATIONS FOR SIZES OF EACH ITEM.) 16. SUPPORT ROOMS ARE FOR STORAGE AND UTENSIL WASHING ONLY. NO VEGETABLE WASHING OR FOOD PREP. TO BE DONE FOOD SERVICE NOTES 1. REQUIREMENTS SHOWN ARE FOR ONE ITEM, TO DERIVE TOTAL MULTIPLY BY QUANTITY SHOWN. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE MAG. STARTERS. DISCONNECT SWITCHES, INTERLOCKS AND THERMO-OVERLOAD PROTECTION WHERE REQUIRED. 3. PLUMBING CONTRACTOR SHALL PROVIDE STOP VALVES AHEAD OF ALL OPERATING HANDLES AND FAUCETS. 4. SEE EQUIPMENT PLUMBING AND ELECTRICAL ROUGH -IN DRAWINGS FOR ADDITIONAL INFORMATION. 5. ELECTRICAL POWER TO COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED THRU A SHUNT -TRIP SYSTEM FOR FIRE FUEL SHUT-OFF. ELECTRICAL CONTRACTOR SHALL WIRE CONTROL CIRCUIT TO MICRO SWITCH PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR ON HOOD FIRE PROTECTION SYSTEM. 6. GAS SUPPLY TO ALL COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED WITH AN ELECTRIC VALVE FOR FIRE -FUEL SHUT-OFF. VALVE TO BE SUPPLIED BY THE "K.E.C." AND INSTALLED BY THE "P.C." K.E.C. SHALL CONNECT VALVE TO THE Hnnn FIRE PROTEc TION SYSTEM FOR AUTOMATIC SHUT-OFF. 7. ALL WALK-IN BOX COILS REQUIRE CONNECTIONS TO SOLENOID VALVE, T-STAT, T-CLOCK AND MOTORS AND CONTROL WIRING TO THE REMOTE COMPRESSOR ALL CONNECTIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 8. ALL WALK-IN BOX FIXTURES TO BE PROVIDED BY THE "K.E.C." INSTALLATION AND WIRING TO BE PROVIDED BY THE "E.C." WITH ALL CONDUIT RUN ON EXTERIOR (TOP) OF BOX. \/ArI 11 I DD=A V=DC WHEN USED, TO RE MINIMUM OF SIX INCHES ABOVE THE FLOOD LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 10. WALL BACKING PROVIDED BY GENERAL CONTRACTOR. 11. PLUMBING CONTRACTOR TO SUPPLY GREASE TRAP AS REQUIRED BY CODE. 12. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER ON CASTERS WITH FLEXIBLE UTILITY QUICK DISCONNECTS OR FIXED ON S/S LEGS. 13. ALL NEW EXHAUST HOODS WILL BE CONSTRUCTED TO MEET THE FOLLOWING STANDARDS: NSF, UL AND NFPA-96. ALL NEW HOODS TO BEAR UL CLASSIFIED LABEL WITHOUT DAMPERS IN EXHAUST VENT COLLARS. HOODS ARE DESIGNED TO MEET OR EXCEED 50 FPM CAPTURE VELOCITY AT THE COOKING SURFACE EDGE AND HAVE A 6" MIN. OVERHANG AT ALL EXPOSED COOKING AREAS. 14. BACK SPLASHES OF EQUIPMENT SHALL BE SEALED TO WALLS WITH CLEAR SILICONE CAULK IN A NEAT WORKMAN LIKE MANNER. SHEET NOTES This plan represents a food service layout of culinary, beverage, systems and related equipment for the convenience of owner/operator, architects, mechanical, electrical, and plumbing engineers, contractors, kitchen equipment fabricators, kitchen equipment contractors and other related trades. The base plan has been made available from information provided by others, not limited to measurements, electronic backgrounds, grid lines and existing or proposed building systems, not limited to (plumbing, structural, concrete, ductwork, electrical and mechanical). General contractors, subcontractors, kitchen equipment dealers, contractors, installers, related and non -related contractors, are responsible for securing and obtaining their own measurements and specinC information. Information indicated on these plans are generally for food service equipment and are intended as reference only. RJS Associates is not responsible for the engineering or integration of related engineering and disciplines throughout the full set of construction documents specific to the food service equipment in relation to the structural, architectural, mechanical, plumbing and electrical trades, unless otherwise specifically provided for in the plans and specifications. RJS Associates assumes no responsibility for work done by any and all architects, engineers, consultants or contractors, or for any changes made necessary by local, state, or national building codes, ordinances, structural conditions, or by the substitution or changes in equipment shown on this plan(s). Contractors are to make allowances for internal and external final connections on the food service equipment, waste piping, valves, back -flow prevention, traps, drain grates, fluid /gas regulators, faucets, steam traps, starting switches and motors, except where specifically noted in the food service specifications, section 11400. These plans, designs, notes, details and specifications herein are the exclusive property of RJS Associates and may not be reproduced or used by anyone, either in part or in their entirety, without first securing written permission by RJS Associates. The unauthorized reproduction, copying, or use of this drawing / plan(s) or electronic file or disc containing information specific to this project without the expressed written consent of RJS Associates is prohibited and any infringement will be subject to any and all remedies available to RJS Associates under the Copyright Laws of the United States. REVISIONS CONFORMED SET MARCH 22, 2019 Qi 2-19-2019 BID SUPPLEMENT I m 2-22-2019 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N Phase 2 of 5 ��yt1�lltltft Corr 4(v� OJ�ArAIV CA a� RJS + ASSOCIATES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T:8W.434.2700 F:860.434.3735 www.dsrsd.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT PLUMBING ROUGH -IN PLAN & SCHEDULE DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. E Z U 0) O ^L LL Z a - SCALE: 1/4" = V-0" f-S = I * 4. 1 0 L E 3 Z U 41 .o Z EL Uk U IWIUUWIUU 11 IU11WI mail III UUUIUIU7II n Iu1U awl al,111N."ilim11 IT ni'U' n . m m m n KITCHEN RI ■ ■ ■ ■ ■ O FIRE EXTINGUISHER ' ■ ■ ' 0 ■ 125 12 58 FS-1.7.1 ' D 0 GIRLS TOILET icD C7 I I I- --CORNER GUARDS cG I \ I \ '0 I 1 I 1 0 ILL c I ly I 1y c re) -- ---10 IPa -- izo Ips L I J I- I I _ 1 I I T I L_L_- J L_J�-_ I I ,_ 211030 _ 2ME0?t III L= _ - --------------------- _ 8'-10"L X 9'-0"H S/S WALL FLASHING CUST IFFICE I I I I LLI I I I - - - 13N78Y3 3aL1 I EXTINGUISHER 0 FIRE `� I \0/ -- \O/ EXTINGUISHER\L II -------------�: 1 MANUAL KITCHEN! PULL STATION j MPS K FIRE EXTINGUISHER KITCHEN FOODSERVICE EQUIPMENT LIFE SAFETY & SPECIAL CONDITIONS PLAN 9 U Li (A) _.._.._.._,.._ PLAN VIEW .............................................. HEIGHT ABOVE (B) FLOOR (C) OVERALL HEIGHT OF BACKING (B) OVERALL WIDTH vi �nv,nanG- (A) (C) COVE BASE BY G.C. ELEVATION 36 T 18 F54 SEE NOTE * NOTE: WALL BACKING LENGTHS ARE MINIMUM. ALWAYS EXTEND TO NEXT STUD OVER IN EACH DIRECTION. SEE BUILDING CONDITIONS PLAN. MATERIAL: 16 Ga. GALVANIZED I EQUIPMENT WALL BACKING DETAIL 5-1.7. N.T.S. SYMBOLS 11 WALL BACKING FOR EQUIPMENT ABOVE 36" (BY GENERAL CONTRACTOR) LEGEND SYMBOLS ABBREVIATIONS OREFRIGERATION CONNECTION FS FLOOR SINK a UTILITY CONNECTION FT FLOORTROUGH CC CORNER GUARD MPS MANUAL PULL STATION OK-CLASS PORTABLE FIRE EXTINGUISHER ON DOWN FROM ABOVE OUTILITY STUB UP FROM FIN FLOOR V ' BCV ERAGE I.UIVDUlI STUB UP CORRIDOR HEALTH DEPT. NOTES 1. ALL FOOD SERVICE EQUIPMENT, FABRICATED ITEMS, AND THEIR INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION (N.S.F.) REQUIREMENTS. 2. ALL STATIONARY EQUIPMENT AND FIXTURES TO BE SEALED TO THE WALL OR ADJACENT EQUIPMENT. USE ALUMINUM COLOR AT STAINLESS STEEL AND CLEAR AT ALL OTHERS. I ALL SINKS IN 1HE FOOD FACIL11 11 MUST, BE PROVIDED HOT WATER (MIN. 110 DEG. F.) AND COLD RUNNING WATER UNDER PRESSURE AND WILL HAVE A PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MINIMUM OF 10 SECONDS. 4. A HAND SINK IS PROVIDED IN EACH FOOD PREPARATION AREA WITH SINGLE SERVICE TOWEL AND SOAP DISPENSER. 5. 3-COMPARTMENT SINKS ARE PROVIDED WITH MIXING VALVE FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. 6. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD PREPARATION, PACKAGING, AND PROCESSING AREAS AND WHERE UTENSILS 7. A MIN. OF 10 FOOT CANDLES (108 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD AND UTENSIL STORAGE ROOMS, TOILET, AND DRESSING ROOMS. 8. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL AREAS DURING GENERAL CLEANUP ACTIVITIES. 9. ALL SHELVING OVER WET AREAS (SINKS, MOP SINKS, ETC.) WILL BE STAINLESS STEEL. 10. SHATTER SHIELDS OR SHATTERPROOF LIGHT BULBS TO BE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE AREAS. 11. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 12. FLOOR SINKS UNDER EQUIPMENT MUST BE 50% EXPOSED AND EASILY ACCESSIBLE FOR CLEANING AND SERVICING. 13. ALL EXHAUST HOODS TO BE A MIN. 22 GA. STAINLESS STEEL, U.L. LISTED, AND CONSTRUCTED AND INSTALLED TO ALL U.L. AND CSCB 101.1.1, & CSFC 609.1 SPECIFICATIONS. EXHAUST DUCTS TO BE A MIN. 16 GA. STEEL. (TYPE 1 HOOD DUCTS TO HAVE WELDED SEAMS) 14. ALL FLOOR TILE TO BE SMOOTH UNDER ALL EQUIPMENT, AND YYALI�YVAYS I0 HAVE A LIGHl 1CAIURE ONLY. 15. ALL 3-COMPARTMENT SINKS TO HAVE A MIN. COMPARTMENT SIZE OF 18" X 18" X 12" DEEP, WITH A MIN. 18" DRAIN BOARD ON EACH END. PROVIDE WITH 8" HIGH INTEGRAL BACK SPLASH AT ALL WALLS. (SEE FOOD SERVICE SPECIFICATIONS FOR SIZES OF EACH ITEM.) 16. SUPPORT ROOMS ARE FOR STORAGE AND UTENSIL WASHING ONLY. NO VEGETABLE WASHING OR FOOD PREP. TO BE DONE FOOD SERVICE NOTES 1. REQUIREMENTS SHOWN ARE FOR ONE ITEM, TO DERIVE TOTAL MULTIPLY BY QUANTITY SHOWN. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE MAG. STARTERS. DISCONNECT SWITCHES, INTERLOCKS AND THERMO-OVERLOAD PROTECTION WHERE REQUIRED. 3. PLUMBING CONTRACTOR SHALL PROVIDE STOP VALVES AHEAD OF ALL OPERATING HANDLES AND FAUCETS. 4. SEE EQUIPMENT PLUMBING AND ELECTRICAL ROUGH -IN DRAWINGS FOR ADDITIONAL INFORMATION. 5. ELECTRICAL POWER TO COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED THRU A SHUNT -TRIP SYSTEM FOR FIRE FUEL SHUT-OFF. ELECTRICAL CONTRACTOR SHALL WIRE CONTROL CIRCUIT TO MICRO SWITCH PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR ON HOOD FIRE PROTECTION SYSTEM. 6. GAS SUPPLY TO ALL COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED WITH AN ELECTRIC VALVE FOR FIRE -FUEL SHUT-OFF. VALVE TO BE SUPPLIED BY THE "K.E.C." AND INSTALLED BY THE "P.C." K.E.C. SHALL CONNECT- VALVE TO THE HOOD FIRE PROTECTION SYSTEM FOR AUTOMATIC SHUT-OFF. 7. ALL WALK-IN BOX COILS REQUIRE CONNECTIONS TO SOLENOID VALVE, T-STAT, T-CLOCK AND MOTORS AND CONTROL WIRING TO THE REMOTE COMPRESSOR ALL CONNECTIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 8. ALL WALK-IN BOX FIXTURES TO BE PROVIDED BY THE "K.E.C." INSTALLATION AND WIRING TO BE PROVIDED BY THE "E.C." WITH ALL CONDUIT RUN ON EXTERIOR (TOP) OF BOX. 94 VACUUM BREAKERS WHEN USED, TO BE MINIMUM OF SIX INCHES ABOVE THE FLOOD LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 10. WALL BACKING PROVIDED BY GENERAL CONTRACTOR. 11. PLUMBING CONTRACTOR TO SUPPLY GREASE TRAP AS REQUIRED BY CODE. 12. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER ON CASTERS WITH FLEXIBLE UTILITY QUICK DISCONNECTS OR FIXED ON S/S LEGS. 13. ALL NEW EXHAUST HOODS WILL BE CONSTRUCTED TO MEET THE FOLLOWING STANDARDS: NSF, UL AND NFPA-96. ALL NEW HOODS TO BEAR UL CLASSIFIED LABEL WITHOUT DAMPERS IN EXHAUST VENT COLLARS. HOODS ARE DESIGNED TO MEET OR EXCEED 50 FPM CAPTURE VELOCITY AT THE COOKING SURFACE EDGE AND HAVE A 6" MIN. OVERHANG AT ALL EXPOSED COOKING AREAS. 14. BACK SPLASHES OF EQUIPMENT SHALL BE SEALED TO WALLS WITH CLEAR SILICONE CAULK IN A NEAT WORKMAN LIKE MANNER. SHEET NOTES This plan represents a food service layout of culinary, beverage, systems and related equipment for the convenience of owner/operator, architects, mechanical, electrical, and plumbing engineers, contractors, kitchen equipment fabricators, kitchen equipment contractors and other related trades. The base plan has been made available from information provided by others, not limited to measurements, electronic backgrounds, grid lines and existing or proposed building systems, not limited to (plumbing, structural, concrete, ductwork, electrical and mechanical). General contractors, subcontractors, kitchen equipment dealers, contractors, installers, related and non -related contractors, are responsible for securing and obtaining their own measurements and specific information. Information indicated on these plans are generally for food service equipment and are intended as reference only. RJS Associates is not responsible for the engineering or integration of related engineering and disciplines throughout the full set of construction documents specific to the food service equipment in relation to the structural, architectural, mechanical, plumbing and electrical trades, unless otherwise specifically provided for in the plans and specifications. RJS Associates assumes no responsibility for work done by any and all architects, engineers, consultants or contractors, or for any changes made necessary by local, state, or national building codes, ordinances, structural conditions, or by the substitution or changes in equipment shown on this plan(s). Contractors are to make allowances for internal and external final connections on the food service equipment, waste piping, valves, back -flow prevention, traps, drain grates, fluid /gas regulators, faucets, steam traps, starting switches and motors, except where specifically noted in the food service specifications, section 11400. These plans, designs, notes, details and specifications herein are the exclusive property of RJS Associates and may not be reproduced or used by anyone, either in part or in their entirety, without first securing written permission by RJS Associates. The unauthorized reproduction, copying, or use of this drawing / plan(s) or electronic file or disc containing information specific to this project without the expressed written consent of RJS Associates is prohibited and any infringement will be subject to any and all remedies available to RJS Associates under the Copyright Laws of the United States. REVISIONS CONFORMED SET MARCH 22, 2019 2-19-2019 BIDSUPPLEMENT 1 ® 2-22-2019 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N Phase 2 of 5 o � 9 .�`��ttttt�st111NtJ///f RIS + A_SSOCIATES INTEGRATEDFOODSERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T:860.434.2700 F:860.434.3735 www.gsfsd.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD. CT. 06109 ( 8 6 0 ) 5 6 3 - 6 1 6 4 TITLE FOOD SERVICE EQUIPMENT LIFE SAFETY & SPECIAL CONDITIONS PLAN DATE 11/02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. SCALE: 1/4"=1'-0" FS=1*5*1 u� l uwW UWI WWllu WWI@ n Uy Dillalluuui o n -- if1♦ ��� 9�"�n1. '�JST FFICE LEGEND SYMBOLS ABBREVIATIONS u REFRIGERATION CONNECTION FS FLUUK SINK a UTILITY CONNECTION FT FLOOR TROUGH CC CORNER GUARD MPS MANUAL PULL STATION OK-CLASS PORTABLE FIRE EXTINGUISHER ON DOWN FROM ABOVE O UTILITY STUB UP FROM FIN FLOOR OBEVERAGE CONDUIT STUB UP SYMBOLS WALL BACKING FOR EQUIPMENT ABOVE 36' I��••- -I (BY GENERAL LUN I RA(. I UK) C7 ME) $ ` 2'-8" 61-5" I � I 'j ° \ i OP - �I I °' I I 2'1 7. I I I I FOOD ' ��' ---� MANAGE OFFICE KITCHEN FOODSERVICE EQUIPMENT SLAB PENETRATIONS PLAN o� M 0 3" NOTE: ROUGH -IN DIMENSIONS ARE BASED UPON ELECTRONIC BACKGROUNDS PROVIDED BY MOSER PILON NELSON, ARCHITECTS, DATED 10-15-18. RJS ASSOCIATES DOES NOT WARRANT THE ACCURACY OF THE BACKGROUNDS OR THE DIMENSIONS REFERENCED ON RJS ASSOCIATES DRAWINGS., THESE DIMENSIONS ARE PROVIDED AS A CONVENIENCE. IT IS THE RECOMMENDATION OF RJS ASSOCIATES THAT THE KITCHEN EQUIPMENT, ELECTRICAL, MECHANICAL, PLUMBING AND GENERAL CONTRACTORS AS APPLICABLE, CREATE THEIR REFERENCE DIMENSIONED ROUGH -IN DRAWINGS. IT IS r1 rn-rugn TUAT F:TF=1 IF) \/FRTPTf aTTf1N RF rum i TTCR R[Ll.lJ1'11.11_Ivvt-V I I 11-11 1 11_1-v . V F-I.�1 1-1 PERFORMED BY THE APPLICABLE CONTRACTORS PRIOR TO POURING OF ANY SLABS OR FABRICATION OF CUSTOM EQUIPMENT. NOTE: I TAIL DI IAIC R. I nrATTnNI OF ROOF TOP FCII ITPMENt FOR SCHEMATIC PURPOSE ONLY. Ll1YL 1\VIYV Vl Lvw-I. a.v.Y v. ��•�-• VERIFY BRACT LOCATION WITH ARCHITECTURAL DRAWINGS AND SITE CONDITIONS. NOTE: UTILITY CURBS SHALL BE UTILIZED IN KITCHEN AND DISHWASHING AREAS, TO FACILITATE THE CLEANING OF FLOORS IN WET AREAS. CONTRACTOR SHALL GROUP AND CONSOLIDATE THE STUB -UPS INTO GROUPS WHERE POSSIBLE TO MINIMIZE THE NUMBER OF CURBS. :TERIA HEALTH DEPT. NOTES 1. ALL FOOD SERVICE EQUIPMENT, FABRICATED ITEMS, AND THEIR INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION (N.S.F.) REQUIREMENTS. 1. Tn ALL I A 11UNAKT EQUIPPILN. AND FIBI --SE.a LED J-U THE WALL OR ADJACENT EQUIPMENT. USE ALUMINUM COLOR AT STAINLESS STEEL AND CLEAR AT ALL OTHERS. 3. ALL SINKS IN THE FOOD FACILITY MUST BE PROVIDED WITH HOT WATER (MIN. 110 DEG. F.) AND COLD RUNNING WATER UNDER PRESSURE AND WILL HAVE A PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MINIMUM OF 10 SECONDS. 4. A HAND SINK IS PROVIDED IN EACH FOOD PREPARATION AREA WITH SINGLE SERVICE TOWEL AND SOAP DISPENSER. 5. 3-COMPARTMENT SINKS ARE PROVIDED WITH MIXING VALVE FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. 6. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD PREPARATION, PACKAGING, AND PROCESSING AREAS AND WHERE UTENSILS 7. A MIN. OF 10 FOOT CANDLES (108 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD AND UTENSIL STORAGE ROOMS, TOILET, AND DRESSING ROOMS. 8. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL AREAS DURING GENERAL CLEANUP ACTIVITIES. 9. ALL SHELVING OVER WET AREAS (SINKS, MOP SINKS, ErC.) WILL BE STAINLESS STEEL. 10. SHATTER SHIELDS OR SHATTERPROOF LIGHT BULBS TO BE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE AREAS. 11. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 12. FLOOR SINKS UNDER EQUIPMENT MUST BE 50% EXPOSED AND EASILY ACCESSIBLE FOR CLEANING AND SERVICING. 13. ALL EXHAUST HOODS TO BE A MIN. 22 GA. STAINLESS STEEL, U.L. LISTED, AND CONSTRUCTED AND INSTALLED TO ALL U.L. AND CSCB 101.1.1, & CSFC 609.1 SPECIFICATIONS. EXHAUST DUCTS TO BE A MIN. 16 GA. STEEL. (TYPE 1 HOOD DUCTS TO HAVE WELDED SEAMS) 14. ALL FLOOR TILE TO BE SMOOTH UNDER ALL EQUIPMENT, AND WALKWAYS TO HAVE A LIGHT TEXTURE ONLY. 15. ALL 3-COMPARTMENT SINKS TO HAVE A MIN. COMPARTMENT SIZE OF 18" X 18" X 12" DEEP, WITH A. MIN. 18" DRAIN BOARD ON EACH END. PROVIDE WITH 8" HIGH INTEGRAL BACK SPLASH AT ALL WALLS. (SEE FOOD SERVICE SPECIFICATIONS FOR SIZES OF EACH ITEM.) 16. SUPPORT ROOMS ARE FOR STORAGE AND UTENSIL WASHING ONLY. NO VEGETABLE WASHING OR FOOD PREP. TO BE DONE FOOD SERVICE NOTES 1. REQUIREMENTS SHOWN ARE FOR ONE ITEM, TO DERIVE l TOTAL MULTIPLY BY QUANTITY SHOWN. 2. ELECTRICAL CONTRACTOR SHALL PROVIDE MAG. STARTERS. DISCONNECT SWITCHES, INTERLOCKS AND THERMO-OVERLOAD PROTECTION WHERE REQUIRED. _-_ 3. PLUMBING CONTRACTOR SHALL PROVIDE STOP VALVES AHEAD OF ALL OPERATING HANDLES AND FAUCETS, 4. SEE EQUIPMENT PLUMBING AND ELECTRICAL ROUGH -IN DRAWINGS FOR ADDITIONAL INFORMATION. UIPMENT WHERE REQUIRED 5. ELECTRICAL POWER TO COOKING EQ SHALL BE PROVIDED THRU A SHUNT -TRIP SYSTEM FOR FIRE FUEL SHUT-OFF. ELECTRICAL CONTRACTOR SHALL WIRE CONTROL CIRCUIT TO MICRO SWITCH PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR ON HOOD FIRE PROTECTION SYSTEM. 6. GAS SUPPLY TO ALL COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED WITH AN ELECTRIC VALVE FOR FIRE -FUEL SHUT-OFF. VALVE TO BE SUPPLIED BY THE "K.E.C." AND INSTALLED BY THE "P.C." K.E.C. SHALL CONNECT VALVE TO THE HOOD FIRE PROTECTION SYSTEM FOR AUTOMATIC SHUT-OFF. 7. ALL WALK-IN BOX COILS REQUIRE CONNECTIONS TO SOLENOID VALVE, T-STAT, T-CLOCK AND MOTORS AND CONTROL WIRING TO THE REMOTE COMPRESSOR ALL CONNECTIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. S. ALL WALK-IN BOX FIXTURES TO BE PROVIDED BY THE "K.E.C." INSTALLATION AND WIRING TO BE PROVIDED BY THE "E.C." WITH ALL CONDUIT RUN ON EXTERIOR (TOP) OF BOX. 9. VACUUM BREAKERS WHEN USED, TO BE MINIMUM OF SIX INCHES ABOVE THE FLOOD LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 10. WALL BACKING PROVIDED BY GENERAL CONTRACTOR. 11. PLUMBING CONTRACTOR TO SUPPLY GREASE TRAP AS REQUIRED BY CODE. 12. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER ON CASTERS WITH FLEXIBLE UTILITY QUICK DISCONNECTS OR FIXED ON S/S LEGS. 13. ALL NEW EXHAUST HOODS WILL BE CONSTRUCTED TO MEET THE FOLLOWING STANDARDS: NSF, UL AND NFPA-96. ALL NEW HOODS TO BEAR UL CLASSIFIED LABEL WITHOUT DAMPERS IN EXHAUST VENT COLLARS. HOODS ARE DESIGNED TO MEET OR EXCEED 50 FPM CAPTURE VELOCITY AT THE COOKING SURFACE EDGE AND HAVE A 6" MIN. OVERHANG AT ALL EXPOSED COOKING AREAS. 14. BACK SPLASHES OF EQUIPMENT SHALL BE SEALED TO WALLS WITH CLEAR SILICONE CAULK IN A NEAT WORKMAN LIKE MANNER. SHEET NOTES This plan represents a food service layout of culinary, beverage, systems and related equipment for the convenience of owner/operator, architects, mechanical, electrical, and plumbing engineers, contractors, kitchen equipment fabricators, kitchen equipment contractors and other related trades. The base plan has been made available from information provided by others, not limited to measurements, electronic backgrounds, grid lines and existing or proposed building systems, not limited to (plumbing, structural, concrete, ductwork, electrical and mechanical). General contractors, subcontractors, kitchen equipment dealers, contractors, installers, related and non -related contractors, are responsible for securing and obtaining their own measurements and specific information. Information indicated on these plans are generally for food service equipment and are intended as reference only. RJS Associates is not responsible for the engineering or integration of related engineering and disciplines throughout the full set of construction documents specific to the food service equipment in relation to the structural, architectural, mechanical, plumbing and electrical trades, unless otherwise specifically provided for in the plans and specifications. RJS Associates assumes no responsibility for work done by any and all architects, engineers, consultants or contractors, or for any changes made necessary by local, state, or national building codes, ordinances, structural conditions, or by the substitution or changes in equipment shown on this plan(s). Contractors are to make allowances for internal and external final connections on the food service equipment, waste piping, valves, back -flow prevention, traps, drain grates, fluid /gas regulators, faucets, steam traps, starting switches and motors, except where specifically noted in the food service specifications, section 11400. These plans, designs, notes, details and specifications herein are the exclusive property of PUS Associates and may not be reproduced or used by anyone, either in part or in their entirety, without first securing written permission by PUS Associates. The unauthorized reproduction, copying, or use of this drawing / plan(s) or electronic file or disc containing information specific to this project without the expressed written consent of RJS Associates is prohibited and any infringement will be subject to any and all remedies available to RJS Associates under the Copyright Laws of the United States. REVISIONS 2-19-2019 BID SUPPLEMENT I © 2-22-2019 BID SUPPLEMENT 2 STATE PROJECT NO. .ttttttt�ltt illllt/�� kg C;,JNCANp� C--�'� _ 9Y #7 2© ; ����1F1llJSiitlt��> RJS + ASSOCIA_TES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434.3735 www.1sfsd.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 5 6 3 - 6 1 6 4 TITLE FOOD SERVICE EQUIPMENT SLAB PENETRATIONS PLAN DATE COPYRIGHT Moser Pilon Nelson Architects DWG. NO. E Z U N O LL^L ^Z LL SCALE: 1/4"=1'-0" FS=19791 KITCHEN EXHAUST/CFM SCHEDULE t; ,-. I— t; °- - a- a a = v c~n 7) W =N = _ _ w" W L1J UJU0 w w wz ¢� ¢ Z ¢ Z ¢- 2:z c� U U 1 c�1- U U U ITEM ¢CJ ¢� ¢� a,,- QU ¢� I.L. ¢� ¢i �- HVAC NO QTY EQUIPMENT CATEGORY = o = v = Ln _ ¢ = o = = va) = Q REMARKS 13 1 EXHAUST HOOD 13X12 1941 42 - - REFER TO FS-1.81 TO 1.8.3 FOR MECHANICAL DETAILS a) E z U N O d Z d I'rvlll'JII11illWII�iIIIIl11JUItlI�lUl !ilUIlillill�,WUIlu1J IIUaUli)II'ili Illpl(li!illillli�111I11iIW1i�1UlUWl�ll1 QlllilUl!iWllpl II ;�1 II III 1 I I,II fflu", ��II�, I�li�`IJ� ll'llil-llllll l'll i II I I lill.Ill�lll llil l l'IIIIII I p ii' ,h�ff 111 lull fill 11 GIRLS 71 T ------ r� I 1 /0\ /0\ I L1 -- �- �-------------------------� - _ BOYS' TOILET ---10 tao J30 IPo I I b----- -J -r-_'I r __ °llllllll(fil � _ = lllllllll((I ` = -== � fi----=f • Illlllllllli ---------------- IJIIIIIIIIII - _ ' I I I I F-I I F, 11 ih I 1 Ell LI -- 1941 _ ---- -�-� C.F.M. L, ."W ST I I I I _ FFICE -�--- -- FOOD MA A OFFICE I I� 1 II II I i1 I I II 1 I II OF ---I i KITCHEN KITCHEN FOODSERVICE EQUIPMENT EXHAUST CFM PLAN SCALE: 1/4"=1'-0" CORRIDOR :TERIA HEALTH DEPT. NOTES REVISIONS CONFORMED SET MARCH 22, 2019 1. ALL FOOD SERVICE EQUIPMENT, FABRICATED ITEMS, AND THEIR 0 2-I9-2019 BID SUPPLEMENT I INSTALLATION SHALL MEET NATIONAL SANITATION FOUNDATION ® 2-22-2019 BID SUPPLEMENT 2 (N.S.F.) REQUIREMENTS. 2 ALL STATIONARY EQUIPMENT AND FIXTURES TO RF SEALED TO HE WA TLL OR ADJACENT EQUIPMENT. USE ALUMINUM COLOR AT STAINLESS STEEL AND CLEAR AT ALL OTHERS. 3. ALL SINKS IN THE FOOD FACILITY MUST BE PROVIDED WITH HOT WATER (MIN. 110 DEG. F.) AND COLD RUNNING WATER UNDER PRESSURE AND WILL HAVE A PREMIXING FAUCET CAPABLE OF SUPPLYING WARM WATER FOR A MINIMUM OF 10 SECONDS. 4. A HAND SINK IS PROVIDED IN EACH FOOD PREPARATION AREA WITH SINGLE SERVICE TOWEL AND SOAP DISPENSER. 5. 3-COMPARTMENT SINKS ARE PROVIDED WITH MIXING VALVE FAUCETS CAPABLE OF REACHING EACH COMPARTMENT. 6. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD PREPARATION, PACKAGING, AND PROCESSING AREAS AND WHERE UTENSILS 7. A MIN. OF 10 FOOT CANDLES (108 LUX) OF LIGHT, MEASURED 30" OFF THE FLOOR TO BE PROVIDED IN ALL FOOD AND UTENSIL STORAGE ROOMS, TOILET, AND DRESSING ROOMS. 8. A MIN. OF 20 FOOT CANDLES (215 LUX) OF LIGHT, MEASURED 30" STATE PROJECT NO. OFF THE FLOOR TO BE PROVIDED IN ALL AREAS DURING GENERAL CLEANUP ACTIVITIES. 132-0089 N 9. ALL SHELVING OVER WET AREAS (SINKS, MOP SINKS, ETC.) Phase 2 of 5 WILL BE STAINLESS STEEL. 10. SHATTER SHIELDS OR SHATTERPROOF LIGHT BULBS TO BE PROVIDED FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE AREAS. 11. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE. 12. FLOOR SINKS UNDER EQUIPMENT MUST BE 50% EXPOSED AND EASILY ACCESSIBLE FOR CLEANING AND SERVICING. 13. ALL EXHAUST HOODS TO BE A MIN. 22 GA. STAINLESS STEEL, U.L. LISTED, AND CONSTRUCTED AND INSTALLED TO ALL U.L. AND CSCB 101.1.1, & CSFC O 609.1 SPECIFICATIONS. EXHAUST DUCTS TO BE A MIN. 16 GA. STEEL. (TYPE 1 HOOD DUCTS TO HAVE WELDED SEAMS) 14. ALL FLOOR TILE TO BE SMOOTH UNDER ALL EQUIPMENT, AND O WALKWAYS TO HAVE A LIGHT TEXTURE ONLY. 15. ALL 3-COMPARTMENT SINKS TO HAVE A MIN. COMPARTMENT SIZE OF 18" X 18" X 12" DEEP, WITH A MIN. 18" DRAIN BOARD ON EACH END. PROVIDE WITH 8" HIGH INTEGRAL BACK SPLASH AT ALL WALLS. (SEE FOOD SERVICE SPECIFICATIONS FOR SIZES OF EACH ITEM.) 16. SUPPORT ROOMS ARE FOR STORAGE AND UTENSIL WASHING ONLY. NO VEGETABLE WASHING OR FOOD PREP. TO BE DONE o � � o FOOD SERVICE NOTES W� 1. REQUIREMENTS SHOWN ARE FOR ONE ITEM, TO DERIVE r , TOTAL MULTIPLY BY QUANTITY SHOWN. W A 2. ELECTRICAL CONTRACTOR SHALL PROVIDE MAG. STARTERS. O r DISCONNECT SWITCHES, INTERLOCKS AND THERMO-OVERLOAD F+M PROTECTION WHERE REQUIRED. CA - V1 3. PLUMBING CONTRACTOR SHALL PROVIDE STOP VALVES r T AHEAD OF ALL OPERATING HANDLES AND FAUCETS. w 4. SEE EQUIPMENT PLUMBING AND ELECTRICAL ROUGH -IN DRAWINGS O FOR ADDITIONAL INFORMATION. Q1 5. ELECTRICAL POWER TO COOKING EQUIPMENT, WHERE REQUIRED, SHALL BE PROVIDED THRU A SHUNT -TRIP SYSTEM FOR FIRE FUEL O SHUT-OFF. ELECTRICAL CONTRACTOR SHALL WIRE CONTROL rT�� CIRCUIT TO MICRO SWITCH PROVIDED BY KITCHEN EQUIPMENT V1 CONTRACTOR ON HOOD FIRE PROTECTION SYSTEM. O 6. GAS SUPPLY TO ALL COOKING EQUIPMENT, WHERE REQUIRED, r SHALL BE PROVIDED WITH AN ELECTRIC VALVE FOR FIRE -FUEL Il••••+1 SHUT-OFF. VALVE TO BE SUPPLIED BY THE "K.E.C." AND INSTALLED BY THE "P.C." K.E.C. SHALL CONNECT VALVE TO THE HOOD FIRE PROTECTION SYSTEM FOR AUTOMATIC SHUT-OFF. 7. ALL WALK-IN BOX COILS REQUIRE CONNECTIONS TO SOLENOID 940 VALVE, T-STAT, T-CLOCK AND MOTORS AND CONTROL WIRING TO THE REMOTE COMPRESSOR ALL CONNECTIONS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 8. ALL WALK-IN BOX FIXTURES TO BE PROVIDED BY THE "K.E.C." INSTALLATION AND WIRING TO BE PROVIDED BY THE "E.C." WITH ALL CONDUIT RUN ON EXTERIOR (TOP) OF BOX. 9. VACUUM BREAKERS WHEN USED, TO BE MINIMUM OF SIX INCHES L�J ABOVE THE FLOOD LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 10. WALL BACKING PROVIDED BY GENERAL CONTRACTOR. 11. PLUMBING CONTRACTOR TO SUPPLY GREASE TRAP AS REQUIRED BY CODE. 12. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER ON CASTERS WITH FLEXIBLE UTILITY QUICK DISCONNECTS OR FIXED ON S/S LEGS. 13. ALL NEW EXHAUST HOODS WILL BE CONSTRUCTED TO MEET THE FOLLOWING STANDARDS: NSF, UL AND NFPA-96. ALL NEW HOODS TO BEAR UL CLASSIFIED LABEL WITHOUT DAMPERS IN EXHAUST VENT COLLARS. HOODS ARE DESIGNED TO MEET OR EXCEED 50 FPM CAPTURE VELOCITY AT THE COOKING SURFACE EDGE AND HAVE A 6" MIN. OVERHANG AT ALL EXPOSED COOKING AREAS. 14. BACK SPLASHES OF EQUIPMENT SHALL BE SEALED TO WALLS WITH CLEAR SILICONE CAULK IN A NEAT WORKMAN LIKE MANNER. ,1�,:`i�lESlTt?ltTTt7� C tv SHEET NOTES 4 20 1 �fx�ttut::I.t;� This plan represents a food service layout of culinary, beverage, systems and related equipment for the convenience of owner/operator, architects, mechanical, electrical, and plumbing engineers, contractors, kitchen equipment fabricators, kitchen equipment contractors and other related trades. The base plan has been made available from information provided by others, not limited to measurements, electronic backgrounds, grid lines and existing or proposed building systems, not limited to R3S + ASSOCIATES (plumbing, structural, concrete, ductwork, electrical and INTEGRATED FOOD SERVICE DESIGN mechanical). General contractors, subcontractors, P.O. BOX 370 14 HIGH STREET kitchen equipment dealers, contractors, installers, related OLD LYME, CT 06371 T: 860.434.2700 F: 860.434.3735 and non -related contractors, are responsible for securing www.rjsfsd.com and obtaining their own measurements and specific information. Information indicated on these plans are generally for food service equipment and are intended as reference only. RJS Associates is not responsible for the engineering or integration of related engineering and disciplines throughout the full set of construction documents specific to the food service equipment in MO S ER relation to the structural, architectural, mechanical, plumbing and electrical trades, unless otherwise specifically provided for in the plans and specifications. PILON RJS Associates assumes no responsibility for work done by any and all architects, engineers, consultants or contractors, or for any changes made necessary by local, NELSON SON state, or national building codes, ordinances, structural 1 � conditions, or by the substitution or changes in A R C H I T E C T S equipment shown on this plan(s). Contractors are to make allowances for internal and external final 30 J O R D A N LANE connections on the food service equipment, waste piping, W E T H E R S F I E L 3 C T. 06109 (860) 563-6164 valves, back -flow prevention, traps, drain grates, fluid /gas regulators, faucets, steam traps, starting switches and motors, except where specifically noted in the food service specifications, section 11400. TITLE FOOD SERVICE EQUIPMENT EXHAUST CFM PLAN These plans, designs, notes, details and specifications herein are the exclusive property of RJS Associates and may not be reproduced or used by anyone, either in part or in their entirety, without first securing written permission by RJS Associates. The unauthorized reproduction, copying, or use of this drawing / plan(s) or DATE 11/02/2018 electronic file or disc containing information specific to this project without the expressed written consent of RJS COPYRIGHT Associates is prohibited and any infringement will be Moser Pilon Nelson Architects subject to any and all remedies available to RJS Associates under the Copyright Laws of the United States. DWG. NO. FS-1973 REVISIONS CONFORMED SET MARCH 22, 2019 © 2-19-2019 BID SUPPLEMENT I 2-22-2019 BID SUPPLEMENT 2 REV. HOOD INFORMATION TABLE HOOD NUMBER HOOD MODEL EXHAUST AIR FLOW REQUIREMENTS GREASE EXTRACTOR HOOD CONSTRUCTION HOOD WEIGHT (LBS) EXHAUST CFM 1941 T.A.B. PORT STATIC PRESSURE .30" TOTAL HOOD STATIC PRESSURE 42" EXHAUST COLLAR QTY. SIZE TYPE QN LENGTH WIDTH L H 13 KVE 1 13" 12" 5 20yy 131; KSA ALL 18GA. 304 S/STL. 765 - 11 13 _ - 20„ 13„ KSA ALL 18GA. 304 S/STL. - 13" TOTAL EXH. CFM = 1941 ANSUL R-102 SYSTEM IVIIJUIV I ED ITV !r' IRE UMDDIIVET: (1) OEM REGULATED RELEASE (1) 3 GALLON TANK ANSUL R-102 SYSTEM 14 .ail 42"-48" G"VISE `Eo EL "009 11 3 GALLON CABINET MOUNTED 2411 12" ANSUL MICROSWITCH DETAIL POWER TO COOKING EQUIPMENT UPPER SWITCHES SHUNT TRIP BREAKER VOLTAGE FREE BLACK--3_ _BLACK -NGC) N/C CONTACTS FOR INTERCONNECTION RED- - RED VOLTAGE FREE N/O TO THE MUA BROWN CONTACTS FOR HVAC SYSTEM - - - BROWN INTERCONNECTION TO THE COOKING EQUIP. LOWER SWITCHES SHUNT TRIP VOLTAGE FREE N/O BLACK- BLACK CONTACTS FOR _ RED_ _RED VOLTAGE FREE INTERCONNECTION TO THE EXTRA BUILDING ALARM SYSTEM -BROWN BROWN CONTACTS UPPER SWITCH RED (COMMON) o BLACK (NORMALLY OPEN) o - BROWN (NORMALLY CLOSED) o BROWN (NORMALLY OPEN) O FED BLACK (NORMALLY CLOS (COMMON) LOWER SWITCH 0 MICRO -SWITCH r21AMP, L SNAP ACTION SWITCHES. 4 SWITCHES INCLUDED ACTS SHOWN WITH AUTOMAN E COCKED POSITION (READY) FIELD WIRING BY 125/250 VAC SWITCHES ELECTRICAL CONTRACTOR J CEILING CLOSURE PANES CEILING SIDE CLOSURE O g© ©A PANEL HOOD VIEW FRONT ® C 0� CLOSURE CLIPS (PROVIDED BY HALTON) © WALL ATTACHMENT HARDWARE (KEC) ©� PANEL ATTACHMENT HARDWARE (KEC) LIGHT SWITCH/ ^vVERRiDE SWITCH (M.A.R.V.E.L. 6" MIN. TIMER PANEL SERVICE CLEARANCE REQUIRED ON ALL SIDES 1 " FLANGED COLLAR E7 -H 12" 107" - L Typical wiring of Capture -Jet fan W/HALTON SUPPLIED SWITCH PANEL BLACK WHI - B B GREEN W IG LED HOOD LIGHTS BY HALTON LIGHT CIRCUIT TO NEXT Hoop - - - BY ELECTRICIAN ------ GREEN WHITE BLACK SWITCHED LIGHTS z Ld o Ld WHITE � _ BLACK SUPPLY C �"` }- I BLACK CAPACITOR z JUP�PER } RED Q w w Z: D Y o- Q m CD D' o X0 U I :� I I U cD 00 GROUND m0 �j CoH14 O � w �LL-o P y A� o = NEUTRA CAPTURE JET BLOWER MOTO w� I 120/1/60 SPEED 120/1/60 �® 15 AMP CONTROLLER 72 AMPS J w � vVLIGHSWITCH rc 0ITEM # 13 PLAN VIEW CONVECTION OVEN CONVECTION OVEN ITEM # 13 ELEVATION VIEW ELECTRICAL CONNECTION SCHEDULE CONNECTION # CONNECTION DESCRIPTION FROM TO E1-13 120V, 15AMP - HOOD LIGHT POWER - 3 WIRES BUILDING SOURCE HOOD 48L 58" 3 6" MIN. **NOTE** THE HOOD SHOWN ON THIS DRAWING IS DESIGNED AS THOUGH A SINGLE EXHAUST FAN WILL BE USED FOR HOOD H-1. ONE TIMER PANEL IS REQUIRED PER EXHAUST FAN. IT IS THE RESPONSIBILITY OF THE F.S.E.C. TO INFORM HALTON OF THE NUMBER OF EXHAUST FANS BEING UTILIZED ON THIS PROJECT. CEILING CLOSURES BY HALTON UP TO 18" HEIGHT (FIELD INSTALLED KEC) HANGER BRACKET CJ FAN- 24" 84" MAXIMUM 78" MINIMUM KEC TO VERIFY PRIOR TO FABRICATION 1) ANSUL R-102 FIRE SYSTEM 2) ONE TANK SYSTEM (3 GALLON) 3) 3/8" BLACK IRON PIPING (CONCEALED) 3/8" S/STL. APPLIANCE DROPS(EXPOSED) 4) MECHANICAL GAS VALVE = REFER TO MEP DWGS HANGER BRACKET LAYOUT HOODS 96"L - 168"L WITH ONE HOODS 95"L & LESS WILL EXHAUST COLLAR NOT HAVE THE FOUR KVE 3.5" -- B B - 71 o a BRACKETS IN THE CENTER OF HOOD B 3.5" STRUCTURAOL ENGINEER 3.5" TO VERIFY LOCAL -7 REQUIREMENTS. HANGING DC REQUIREMENTS ARE THE RESPONSIBILITY �jj OF INSTALLING CONTRACTOR LOCAL HOODS 96"L - 168"L WITH TWO EXHAUST COLLARS KVE _ ° o A CODES MUST BE FOLLOWED. 3.4" �� A 3.4" A = TOTAL LENGTH OF HOOD B = (A - 7) / 3 C = TOTAL WIDTH OF HOOD D = C - 8.9(KVE/EO) OR 15.9(KVC/EOP) KVC 3.511� B B B � 3.5" ®o o�5.5" DC fI A 10.4 3.511 Cm A = TOTAL LENGTH OF HOOD B = TOTAL WIDTH OF HOOD C = B - 8.9(KVE/EO) OR 15.9(KVC/EOP) 11 c2) KVC 3.5" --1 IfJ.rilf3.5" (1) 1 /2" ALL THREAD "KEC" (2) 1 /2" NUT "KEC" (3) HANGER BRACKET 5. L 10.4" CONNECTICUT CODE NOTES GENERAL NOTES: 1. THIS INSTALLATION IS TO BE MADE IN ACCORDANCE WITH THE R-102 INSTALLATION MANUAL AND IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. 2. THE HOOD INSTALLATION MUST COMPLY WITH CONNECTICUT STATE BUILDING CODE - CSBC 101.1.1 - 101.1.1 STATUTES. 3. THE HOOD INSTALLATION AND USE MUST COMPLY WITH THE CONNECTICUT STATE FIRE SAFETY CODE (CFSC) . 4. THE HOOD INSTALLATION, MAINTENANCE AND USE MUST COMPLY WITH THE CONNECTICUT STATE FIRE PREVENTION CODE (CSFP). GREASE SENSOR (M.A.R.V.E.L.) AUTOMATIC BALANCING DAMPER (M.A.R.V.E.L.) DUCT SENSOR (M.A.R.V.E.L.) _ 0 4„ -Mn `-TAB PORT �25" S.P. SCR ACCESS PANEL -IN 5LNJUN (M.A.R.V.E.L.) 18" MIN. C 3 ITEM # 13 SECTION VIEW GENERAL SPECIFICATIONS 1- HOOD CONSTRUCTION AND DESIGN MEETS NFPA 96 AND UL 710 STANDARD. 2- HOOD IS NSF AND ETL LISTED UNDER THE FOLLOWING FILE NUMBER: ETL #3085193CLE-002 3- ALL INSTALLATION WORK IS TO BE PERFORMED BY QUALIFIED PERSONS AND IN ACCORDANCE WITH STATE AND LOCAL BUILDING CODE REQUIREMENTS. 4- THE INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 96, REMOVAL OF SMOKE AND GREASE LADEN VAPORS FROM COMMERCIAL COOKING EQUIPMENT. 5- ALL EXHAUST DUCTWORK AND TRANSITIONS ARE TO BE PROVIDED BY THE HVAC CONTRACTOR. 6- CLEARANCE FROM HOOD AND DUCTS TO COMBUSTIBLE MATERIAL SHALL BE PER APPLICABLE BUILDING CODES. 7- FOR PROPER OPERATION OF THE HOOD SYSTEM, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO HAVE THE HOOD BALANCED AND TESTED TO ENSURE THAT THE EXHAUST AND SUPPLY REQUIREMENTS OF THE HOOD ARE MET. INSTALLATION REQUIREMENTS KITCHEN EQUIPMENT CONTRACTOR'S REQUIREMENTS 1- PROVIDE DRAWINGS TO APPROPRIATE TRADES REFERENCING UTILITY SERVICE AND COORDINATE FINAL CONNECTION. 2- DELIVER, ASSEMBLE AND INSTALL HALTON SYSTEM PER DRAWING. 3- FURNISH WIRING AND PLUMBING DIAGRAMS T^v E vD USER. 4- THE K.E.0 MUST INFORM HALTON OF ANY CHANGES IN EQUIPMENT OR BUILDING STRUCTURE. FIELD MODIFICATIONS ARE THE RESPONSIBILITY OF THE K.E.C. 5- IF HALTON MANUAL EXHAUST VOLUME DAMPERS ARE PROVIDED, THE K.E.C. IS RESPONSIBLE FOR THEIR INSTALLATION OR TO MAKE ARRANGEMENTS g" WITH OTHER TRADES FOR THEIR INSTALLATION. 4 6- IF HALTON MODEL KVL BACKSHELF STYLE HOODS ARE PROVIDED, THE K.E.C. IS RESPONSIBLE FOR THE INSTALLATION OF THE CAPTURE -JET FAN. TAB PORT -SEE CHART ELECTRICAL CONTRACTOR'S REQUIREMENTS FOR S.P. 1- PROVIDE CONNECT ALL REQUIRED 'VOLTAGES, nn vnn JJ Nom __AND (:UNNLUIUNb, WININU3 UUIVDUII, tIC., t-r-M INr- EXTRACTORS I AND ALL APPLICABLE LOCAL CODES. -GREASE \ CUP F�­ELECTRICAL EQUIPMENT KSA GREASE EXTRACTOR EI-I-ECIIVE AKEA = 1.25 tiQLIANL FEET PER FULL EXTRACTOR EFFECTIVE AREA = 0.75 SQUARE FEET PER HALF EXTRACTOR SEE HOOD SUBMITTAL DRAWINGS FOR EXTRACTOR QUANTITY EXTRACTION OF CONTAMINANTS FROM THE EXHAUST AIR IS PROVIDED BY THE KSA MULTI -CYCLONE GREASE EXTRACTORS. EFFICIENT GREASE EXTRACTION IS ACHIEVED BY FORCING THE EXHAUST AIR TO SPIRAL CONTINUOUSLY IN THE SAME DIRECTION IN THE MULTIPLE CHAMBERS OF THE EXTRACTOR, THUS SEPARATING THE GREASE PARTICLES FROM THE AIR FLOW CENTRIFUGALLY. HIGH EXTRACTION EFFICIENCY AND LOW PRESSURE LOSS OVER THE KSA REMAIN PRACTICALLY CONSTANT. KSA REMOVAL TOOL MODEL• "KFR' KSA EXtRACTOR I S/S L COUPLING S/STL PIPE CID BRACKES/ REQUIREMENTS FLUORESCENT LIGHT FIXTURE 40 WATT MAX BULB= .67 AMP EA. RECESSED INCANDESCENT LIGHT FIXTURE U 150 WATT MAX BULB= 1.25 AMP EA. GLOBE INCANDESCENT LIGHT FIXTURE 100 WATT MAX BULB= .83 AMP EA. LED LIGHT FIXTURES= .30 AMP EA. CAPTURE JET FAN= .72 AMP EA 0 **ALL HOOD CIRCUITS ARE NOT TO EXCEED 15 AMP** **LIGHT BULBS, IF REQUIRED, ARE TO BE PROVIDED KEC** CEILING HEIGHT NOTE IF HALTON COMPANY IS TO PROVIDE CEILING CLOSURE PANELS, THE EXACT DIMENSION OF THE FINISHED CEILING HEIGHT MUST BE PROVIDED PRIOR TO RELEASE. FINISHED CEILING HEIGHT A.F.F.: �PER�FQR�MANCEQ�RITE�RIA OTHER MANUFACTURERS WISHING TO OFFER AN AN ADDITIONAL LOAD CANNOT BE PLACED ON THE ALTERNATE TO THE SPECIFIED MANUFACTURER MUST KITCHEN HVAC SYSTEM. APPLY FOR PERMISSION TO DO SO IN WRITING FROM THE OFFICE OF THE SPECIFYING CONSULTANT. MANUFACTURER MUST PROVIDE A WRITTEN APPLICATION MUST BE RECEIVED BY THE GUARANTEE OF PERFORMANCE, ENSURING THE CONSULTANT AT LEAST TEN WORKING DAYS PRIOR TO SPECIFYING ENGINEER THAT THE SYSTEM WILL THE BID DATE. ANY ALTERNATE SYSTEM MUST MEET PERFORM TO THE ENGINEER'S SATISFACTION WHEN CONSTRUCTION AND PERFORMANCE REQUIREMENTS INSTALLED AND BALANCED ACCORDING TO, DESIGN AIR AND EFFICIENCIES AS OUTLINED IN THIS FLOWS SPECIFICATION. AND RESULTS OF ASTM STANDARD F1704 TEST. (AS DETERMINED BY TAB PORTS AND PRESSURE VS. AIR REQUESTS FOR APPROVAL MUST INCLUDE GREASE FLOW CURVES.) CONSULTANT RESERVES THE RIGHT FILTRATION PERFORMANCE DATA (MICRON SIZE VS. TO REJECT ANY SYSTEM WHICH, WHEN INSTALLED, EXTRACTION EFFICIENCY) AND MANUFACTURERS OWN DOES NOT PROVIDE CAPTURE AND CONTAINMENT AT EXHAUST AIR FLOW CALCULATIONS BASED ON THE THE THRESHOLD FLOW RATE DETERMINED CONVECTIVE HEAT LOAD OF COOKING EQUIPMENT IN ASTM F1704. REJECTED SYSTEM MUST BE BENEATH THE HOOD. REPLACED WITH SPECIFIED SYSTEM, WITH ALL REPLACEMENT COSTS PAID BY MANUFACTURER OF EFFICIENCY COMPARISON DATA TO BE PERFORMED IN REJECTED SYSTEM. ACCORDANCE WITH THE MOST CURRENT ASTM STANDARD F1704 AND INCLUDE RESULTS FOR THE ANY CHANGES IN THE SPECIFIED SIZING OF POWER REQUIRED CAPTURE AND CONTAINMENT EXHAUST AIR WIRING, FAN SIZE, HORSEPOWER REQUIREMENTS, OR FLOW IN ACCORDANCE WITH THE *TEST METHOD TO GAS LINES DUE TO THE USE OF ANY SYSTEM OTHER DETERMINE THE THRESHOLD OF CAPTURE AND THAN THAT WHICH IS SPECIFIED IS THE CONTAINMENT." DATA MUST INCLUDE THERMAL RESPONSIBILITY OF THE ALTERNATE HOOD IMAGING RESULTS VALIDATING CONFORMANCE TO MANUFACTURER, AND MUST BE COORDINATED BY THE ASTM F1704 AND SUPPLY AIR TEMPERATURE HOOD MANUFACTURER AND CONTRACTORS INVOLVED. REQUIREMENT OF 747. MAKE UP AIR WILL BE CALCULATED SO THAT THE SAME AMOUNT OF AIR WILL BE TAKEN FROM THE ZONE AS IS REQUIRED BY THE SPECIFIED SYSTEM. s 11- O0 ¢O 0 W V) W B� w Q 00 Of I-Z Z 0 Z)Qo bi ZILof �bjwa w j D _ _ 1'" 1 I- 1- WoM 0 Ld W zz (n o z O 1.-: iw 1- z z ry (n �j-.) 0 M z M-1 Q w U-z ccWzn� Z ¢0Qz cy� Q Z I. S UU=� in m :D w = U 0 Y V) o I - ow V) Z U ,Zy, U- z LD w 0 �¢9 ❑ w Z a UJ DI i S 0 c� a O U z = Q U m 0 -1 vj z 0, Ye W Uj m m U) I-W ZU w 0U (n LLLL C9 Z � UwQ W v)``' ozo O 1, �F- z�Q of z-0 o O = W 0 U U Z d (n U ZW �U� Q 0�j0 w 0 Z m O0OQ=Ld W Q0E1 1­- V)-- V) Z NH ? fn Q t=-2 O Qa.0 ❑ Q ❑ - m 0 • • Z� z O w U Q 0 z � � a o a_ O M v U m Q 00 (77 ��CD Q =)- CV p _ �o�(0 � 0 QY['- U V) L,J NN I' -I 7 ram-, =1 O Cn m 0 z W J �OU� O 0 w z O m w ry O W w � QO ❑ z Ln co Q w Iw- O 0 Q!� O Q w z Z U'S O w Q Q n C) O (-)w o I O U I- � z 0 O N 0 � I--- z � i U m �,n U F- Q <� zNcl w ry 0 0 p�� z o �U) Lij Q o = o G Q Li J_ Q ry J 0 0 -17 Co 7 U U O Cn O Cn 70 _ In O V Oz Q 1 g C) Q J U) w n,, D O !- C) r. O c� IL o z z v J z O m Ld J z D O = U Q Q ry n p � U O n J O V) 1 U DRAWING TITLE: HOOD DETAILS DRAWING No.: U 18-424 REV NO.: i NOEET of 3 STATE PROJECT NO. 132-0089 N Phase 2 of 5 � , I r- N C) 0 g� Pl a, j T 4, C o !�!llflf illl•11��` i� Rim RJS + ASSOCIATES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434.3735 vnvw.rjsfsd.com MOSEK PILON NIE"L SO ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT EXHAUST HOOD DETAILS DATE 11/02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. � o J-L0 01/11 0 I 00 REVISIONS CONFORMED SET MARCH 22, 2019 0 2-19-2019 BID SUPPLEMENT 1 2-22-2019 BID SUPPLEMENT 2 REV. Al L .Q E z U N O z ELECTRICAL CONNECTION SCHEDULE CONNECTION # CONNECTION DESCRIPTION FROM TO E1-M BROADBAND INTERNET CONNECTION BUILDING SOURCE HOOD #H-1 E2-M FIRE MODE SIGNAL - TO FIRE SUPPRESSION PANEL - 2 WIRES HOOD #H-1 FIRE SYSTEM E3-M 2 WIRES TO SPACE TEMPERATURE SENSOR HOOD #H-1 TEMP SENSOR E4-M MUA SIGNAL (0-10V & START/STOP) - 4 WIRES HOOD #H-1 BMS E5-M POWER SUPPLY TO TOUCH SCREEN HOOD #H-1 TOUCH SCREEN E6-M 2 WIRES TO TOUCH SCREEN TOUCH SCREEN HOOD #H-1 E7-M 120V, 15AMP - MARVEL CONTROLLER POWER - 3 WIRES BUILDING SOURCE HOOD #H-1 E8-M 7 WIRE STP CABLE - PLENUM RATED FT6 24VDC - TO EF VFD HOOD #H-1 VFD E9-M HIGH VOLTAGE WIRING FROM BUILDING SOURCE TO VFD BUILDING SOURCE VFD E10-M HIGH VOLTAGE WIRING FROM VFD TO FAN MOTOR VFD EF FAN MOTOR REMOTE TOUCH SCREEN SURFACE MOUNTED (see detail below) 5" - -I 1 1 .25" I — MARVEL 1 TOUCH SCREEN HOOD #H--1 CONNECTICUT CODE NOTES GENERAL NOTES: 1. THIS INSTALLATION IS TO BE MADE IN ACCORDANCE WITH THE R-102 INSTALLATION MANUAL AND IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. 2. THE HOOD INSTALLATION MUST COMPLY WITH CONNECTICUT STATE BUILDING CODE - CSBC 101.1.1 - 101.1.1 STATUTES. 3. THE HOOD INSTALLATION AND USE MUST COMPLY WITH THE CONNECTICUT STATE FIRE SAFETY CODE (CFSC) . 4. THE HOOD INSTALLATION, MAINTENANCE AND USE MUST COMPLY WITH THE CONNECTICUT STATE FIRE PREVENTION CODE (CSFP). NI r)TF-C - ALL FIELD WIRING AND CONNECTION POINTS ARF Sl1R IFCT Tn C HANGF Dl IF Tn FLFCTRI('AL COMPONENTS) UPDATE OR OBSOLESCENCE. HALTON WILL NOT BE LIABLE FOR ANY CHANGE ORDERS BASED ON DRAWINGS CREATED ONE OR MORE YEARS PRIOR TO PRODUCTION. WHEN RELEASED AN UPDATED SET OF ELECTRICAL DIAGRAMS(S) WILL BE SUPPLIED. I I � Iilll E7—M I i I II 2 WIRES - 24V DC -- 2 WIRES = 24V DC — — — — MUA SIGNAL (0-10V) & START/STOP - 4 WIRES BMS E4—M SIGNAL REPRESENTS DESIGN EXHAUST II FOR ALL HOODS TO SPACE TEMP SENSOR HOOD #H-1 2 WIRES = 24V DC E3—M (Fig. 1-1)PROVIDED "BY HALTON" TO EXHAUST FAN 3 WIRES 10— (REFER TO MECH DWGS)- — — — — — —I HOOD #13 , ' (I PROTECTED POWER 3 WIRES E9 — M (REFER TO # 13H DWGS�- — — — — —I HOOD ��E2-M TO N.O. CONTACTS 2 WIRES - 24V DC — — OF FIRE SYSTEM ( TO W.W.W. PROVIDE RJ45 CAT5E CABLE TO EXHAUST FAN VFD FOR HOOD #H-1 I E1—M — — BROADBAND IN T ERNET CONNECTION 7 WIRE (USE 9 VARIABLE FREQUENCY DRIVE (VFD 6" MIN. ®® -'LEARANCE —� WIRING COVER 6" MIN. CLEARANCE 48" A.F.F. MIN. RECOMMENDED FINISHED FLOOR VFD PHYSICAL DIMENSIONS TO BE DETERMINED BY MOTOR HORSEPOWER AND VOLTAGE. . VFD TO BE MOUNTED IN DESIGNATED LOCATION. VFD MUST BE LOCATED WITHIN 150' OF FAN MOTOR. INSTALL SEPARATE CONDUITS FOR INCOMING & OUTGOING WIRING FROM EACH VFD. • VFD'S ARE SUPPLIED & PROGRAMMED BY HALTON, THEY ARE TO BE INSTALLED & WIRED BY APPLICABLE TRADE OTHER THAN HALTON. © VFD CABINETS ARE NOT SUPPLIED BY HALTON. Ha/ton MAIN SCREt FAST SELE( M.A.R.V.E.L. TOUCH SCREEN ALARM INDICATOR TOTAL SYSTEM AIRFLOW (CFM) KITCHEN SPACE M: A. R: V_ E:I : Stnndnrd Sequence of Operation Ej M.A.R.V.E.L. I & Basic Standard Sequence START UP & SHUT DOWN • OFF • IDLE • COOKING OR ACTIVE MODE MAKE UP AIR • 0-10V OUTPUT FIRE SYSTEM SEQUENCE STANDARD OVERRIDE FEATURE M.A.R.V.E.L. II Standard Sequence SAME SEQUENCE AS M.AR.V.E.L I AND •ABD ADJUSTMENT MAKE UP AIR •SINGLE 0-10VOR SPLIT SIGNAL M.A.RV.E.L. Plus Standard Sequence Some sequence as M.A.R.V.E.L II and e Output to BMS 0-1OV, split or whole • Output to VAV Boxes GREASE SENSOR LOCATION MATRIX GREASE SENSOR #OCATION L 1 MAIN DUCT 2 17 4 - 6 - 8 - 9 - 10 - KMARN.E.L. SYSTEM M.A.RN.E.L. EQUIPMENT CONNECTED LOADS M.A.R.V.E.L. CONTROL PANEL= 10 AMPS EA. M.A.R.V.E.L. PLC AT EACH HOOD SECTION= 4 AMPS EA. (MAXIMUM 3 M.A.R.V.E.L. HOOD PLC's PER 15A CIRCUIT) **ALL CIRCUITS ARE NOT TO EXCEED 15 AMP** NOTES: — - FIELD WIRING (BY E.C.) - 120V - 12AWG MIN.-10AWG MAX. FIELD WIRING (BY E.C.) - 24V - 22AWG MIN.-16AWG MAX. SHIELDED NETWORK CABLES - PROVIDED BY HALTON FIELD INSTALLED GC M. A. R. V. E. L. SCOPE OF WORK RESPONSIBILITY TO BE SELECTED BY GENERAL CONTRACTOR DEFINITIONS FOR REFERENCE: M.A.R.V.E.L. I SYSTEMS = 1 EXHAUST FAN SERVING 1 KITCHEN HOOD M.A.RN.E.L. II SYSTEMS = 1 EXHAUST FAN SERVING MULTIPLE KITCHEN HOODS VFD = VARIABLE FREQUENCY DRIVES CONNECTION LOCATIONS WILL VARY PER SYSTEM, REFER TO HALTON M.A.R.V.E.L. DIAGRAMS FOR SPECIFICS .nPPUCABLE COI`.Tp^,CTOR 1S RLSPVIKVSIBLE FOR THE INSTALLATIONr' OF THE M.A.R.V.E.L. CONTROL PANEL. LOCATION TO BE DETERMINED BY GC AND SHALL BE WITHIN SAME SPACE AS THE KITCHEN HOODS BEING SERVED BY PANEL. (M.A.R.V.E.L. ]HOOD SYSTEMS WILL NOT HAVE SUCH PANEL) 2.APPLICABLE CONTRACTOR TO SUPPLY AND INSTALL 115V (15AMP) DEDICATED CIRCUIT AT M.A.R.V.E.L. CONTROL PANEL 3.APPLICABLE CONTRACTOR TO SUPPLY AND INSTALL RJ45 CAT5E CABLE CONNECTION AT M.A.R.V.E.L. CONTROL PANEL FOR M.A.RN.E.L. II SYSTEMS OR AT KITCHEN HOOD FOR M.A.R.V.E.L. I SYSTEMS FOR I.P. ADDRESS. 4.APPLICABLE CONTRACTOR TO INSTALL SPACE TEMP SENSOR (SUPPLIED BY HALTON) IN SAME SPACE AS KITCHEN HOOD SYSTEM AND 48"-54" A.F.F. NEAREST MUA T-STAI. 5.APPLICABLE CONTRACTOR SHALL SUPPLY AND RUN 2 WIRE 24V DC CONNECTION FROM SPACE TEMP SENSOR TO M.A.R.V.E.L. CONTROL PANEL (M.A.R.V.E.L. II) OR TO KITCHEN HOOD (M.A.R.V.E.L. I) 6.APPLICABLE CONTRACTOR TO SUPPLY AND RUN 2 WIRE 24V DC WIRING FROM ANSUL FIRE SYSTEM EITHER TO M.A.R.V.E.L. CONTROL PANEL (M.A.R.V.E.L. II) OR TO KITCHEN HOOD (M-A,R V,F-1 : I). 7.APPLICABLE CONTRACTOR SHALL CONNECT 2 WIRE COMMUNICATION CABLES (SUPPLIED BY HALTON) FROM HOOD TO HOOD AND TO PANEL AS SHOWN IN HALTON M.A.RN.E.L. DIAGRAM. &APPLICABLE CONTRACTOR TO SUPPLY AND RUN 2 WIRE MUA SIGNAL (0-10V) FROM M.A.R.V.E.L. CONTROL PANEL (M.A.R.V.E.L. II) OR FROM KITCHEN HOOD (M.A.R.V.E.L. 1) TO BMS OR DDC. 9.APPLICABLE CONTRACTOR TO SUPPLY AND RUN 7 WIRE STP PLENUM RATED CABLE (9 WIRE STP CABLE IF VFD IS PROVIDED WITH BYPASS) FROM M.A.R.V.E.L. CONTROL PANEL (M.A.R.V.E.L. 11) OR FROM KITCHEN HOOD (M.A.R.V.E.L. 1) TO EXHAUST FAN VFD(S) (VFD'S AND CABINET SUPPLIED BY HALTON UNLESS OTHERWISE NOTED) 10.APPLICABLE CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF THE VFD(S). LOCATION TO BE DETERMINED BY GC AND SHALL BE WITHIN 150 FEET MAX DISTANCE FROM EXHAUST FAN(S). 11.APPLICABLE CONTRACTOR TO SUPPLY AND INSTALL THREE PHASE OR SINGLE PHASE POWER FEED FROM CIRCUIT BREAKER(S) TO VFD(S). APPLICABLE CONTRACTOR TO SUPPLY AND INSTALL THREE PHASE OR SINGLE PHASE POWER FORM VFD(S) TO EXHAUST / MUA (IF APPLICABLE) MOTORS. ALL TO BE RAN IN SEPARATE CONDUIT. 12.APPUCABLE CONTRACTOR SHALL INSTALL GREASE SENSOR(S), IF PROVIDED, IN MAIN EXHAUST TRUNK, AND WIRE THE SENSOR BACK TO THE DESIGNATED LOCATION. 13.APPLICABLE CONTRACTOR TO SUPPLY AND INSTALL 115V (15AMP) DEDICATED CIRCUIT AT EACH KITCHEN HOOD. (IF HOODS ARE UV, A SECOND 115V DEDICATED CIRCUIT IS REQUIRED.) 14JNSTALLING CONTRACTOR TO BE RESPONSIBLE FOR PROVIDING ADEQUATE ACCESS TO ALL COMPONENTS LOCATED ABOVE HOOD. 15.HALTON REPRESENTATIVE TO PERFORM FINAL FIELD COMMISSIONING ONCE ALL RESPONSIBILITIES ARE COMPLETED ABOVE. NOTES: ALL WIRING AND CABLING TO BE PROVIDED BY ELECTRICAL CONTRACTOR UNLESS STATED OTHERWISE NI r)TF-Q ALL FAN MOTORS MUST BE COMPATIBLE WITH VARIABLE FREQUENCY DRIVES (VFD'S). ALL MOTORS MUST BE CONNECTED TO THREE PHASE POWER. ELECTRONICALLY COMMUTATED MOTORS (ECM) ARE ALSO ACCEPTABLE IF SINGLE PHASE POWER IS TO BE USED. (24V POWER SUPPLY TO THE ECM IS GC) NOTES: ALL VARIABLE FREQUENCY DRIVES (VFD'S) MUST BE INSTALLED WITHIN 150' OF THE EXHAUST FAN. (FIG 1-1) SPACE TEMPERATURE SENSOR 2 CONDUCTOR/SHIELDEBD #LECWG 18 7 TORACTORV.E.L. CONTROL PANEL O SPACE T-STAT (BY HALTON) (4.5"Hx2.75"Wx1.25"D) ROOM THERMOSTAT (GC) 48"-54" A.F.F RECOMMENDED TEMPERATURE SENSOR TO BE MOUNTED AWAY FROM VARYING SOURCES OF HEAT. USUALLY IN CLOSE PROXIMITY TO THE ROOM THERMOSTAT. SENSOR TO BE LOCATED IN SAME "ZONE" AS HOODS THEY SERVE, BY NO CLOSER THAN 10'-12' FROM THE EXHAUST HOOD OR ANY OTHER UNHOODED APPLIANCES. � I— W � 0Ld 0 W L U S W � Q o0 �Bo zwx n ��a w L d O Ld U-1 z m V) �0°� p z O F-: �1- o z O F W 0 0 (n 0- z� n z !K cn z z wc� Q o0 Q - I.- z Z O U = D _ 0 ;7 7) z Q U 0 V) ME 0F OJ W o F=— z WLz � v 1—' Q W a—� Q— ~ ❑ 0W zElf o" c'-) g n- z O W o UO W V < {— UZ W -j J � U Ld Z W Q o` _ � (if°O m m cn ,. (jW OUz . > 5WQ 0 W L� U 5� in¢o zL -a O y �wU Q 0- V)>-U Q 0�Up o U m W 0UO z W p zz w — J-T O QZ� 7_III p(W QQ1— W ULO a_ O Q Hz z N z QOU o D- Q • 0 wo F Y i 00 oLLJ v Q o p o O } TC<) 17] O Cf) LU CD �!W 0 Q ��CO u7 QY� � 3 O U LL1 cool O j� 0 0 z V) m � I �r 0 Ij _ O W Z m O > n- O 0 1 W iL ! ❑o z o Q ^ cr) 0- W Q w � O� � O ry Q W z a- z U�o W Q Q _n O U O O 1 I O i yZ-,;I- O N � z n'QI mIn U U O W j<� z 0 0 O O V) U ry C) W p Q Q J u 0 00 Ij U U �- p ct� u7 I_ o w o z Q Q U) a = o V) Un D Iy D O � O 0 U) a_ O J z ___j z _ z m Q U = O J 0- Q z w J z � UO ry U O 11 -1 O C7 U DR I DETAILS DRAWING No.: U 1 (9-424 NO.: N0.: of STATE PROJECT NO. 132-0089 N Phase 2 of 5 9lb'n�i. 0 - , � a ° 47 20 a ��t�uatuaese�t'• RJS + _ASSOCIATES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 114 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434.3735 mw.rjsfsd.com PILLN N 1� ►1�S Old ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT EXHAUST HOOD DETAILS DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects DWG. NO. FS-1983 L T VERIFIED TRIM E WILL BE BACK RED, WHICH WILL ADDITIONAL FREIGHT BUILDING WALL GES EXTERIOR WALL PANEL ' METAL STRIP #8x3/4" PPH TEK SCREW TRIM ANGLE DETAIL #2 1) Please verify that door swing and location are correct. 5) Special note to General Contractor and his Sub Contractor for quarry tile or concrete wearing floors: the sheet metal panel facings may be susceptible to staining due to excessive moisture created by hydration 2) If this walk—in is to be installed in a depression, or quarry tile is to be of concrete type materials. Therefore, it is absolutely necessary that applied to the interior, depression depths or tile thickness must be each room be properly ventilated. Also note that special precautions specified to insure proper door height. must be taken when using muriatic acid due to effects hydrochloric acid fumes have on aluminum and stainless steel. 3) All site preparation, floor or slab construction, plumbing, electrical 6) This drawing and information contained herein are the exclusive connections (including control wiring) gc. property of American Panel Corporation. It shall be returned to American Panel Corporation upon demand and shall not be reproduced 4) & Electrical: 115-60-1 required above latch side of each door, through in whole or part, disclosed to anyone else, or used without the written ceiling, to operate frame heater and light. consent of American Panel Corporation. IF NOT VERIFIED TRIM ANGLE WILL BE BACK ORDERED, WHICH WILL INCUR ADDITIONAL FREIGHT CHARGES BUILDING WALL : L KIUK PANEL METAL STRIP #8x3/4" PPH TEK SCREW TRIM ANGLE DETAIL #3 A 10/25/18 ADDED THIS SHEET AB NQ—RB REV. DATE DESCRIPTION REV. BY CHK'D BY AMERICAN PANEL CORPORATION American Pane/ 5800 S.E. 78th St. Ocala, Florida 34472 Ph. (352) 245-7055 Fax (352) 245-0726 CUSTOMER: RJS BARBER ASSOCIATES PROJECT: PHILLIP R. SMITH — SOUTH WINDSOR, CT DATE: DRAWN BY: P.O. : 5 16 18 JRT BP SCALE: PROPOSAL#: JOB#: SHEET 3 8"=1 '-0" 1 PD 178804 3 of 3 REVISIONS CONFORMED SET MARCH 22, 2019 Qi 2-19-2019 BID SUPPLEMENT 1 ® 2-22-2019 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N Phase 2 of 5 U PPP_ I �WH w�a � w W�3 �x � O � RJSm+ ASSOCIATES INTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYME, CT 06371 T: 860.434.2700 F: 860.434.3735 www olsd.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EOUIPMENT WALK-IN DETAILS DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects L a> E z U N CL .o z o FS=1*9o3 TIGHT LINK - PRE -PLUMBED DRAIN MANIF❑LD W/BALL VALVE BY MULTITERIA 0 II 46" 592„ VERIFY ITEM # 1 ITEM #3 CS36 MILK COOLER CASHIER KEC COUNTER CASHIER KEC COUNTER �-16 821" END HEAT 8 END 1/4® GLASS LAMPS GLASS INC❑MING WATER C❑NNECTION 0 0 0 ® I � I LIGHT SWITC TIGHT LINK - CENTER, 120/208V 10, 120 AMP SERVICE, BEHIND DOOR —24" ITEM #5 ULS24 UTILITY COUNTER �--16 GA. S/S REMOVABLE UNDERSHELF J-BOX FOR HEAT J-BOX FOR LAMPS LIGHTS PRE -WIRED TO LOAD PRE -WIRED CENTER TO LOAD 120V 1PH 13.3 AMPS CENTER 120V 1PH 3,0 AMPS 84" 90" 3032"— ITEM #3 CLS90 COLD FOOD COUNTER A COLD FOOD COUNTER EER-C®/ATI O N-A �-16 —881"_ END LED 8 END_ GLASS LIGHTS _ GLASS 0 0 0 --------------------------------j LIGHT SWITCH 3 VALVE 3031" 16 GA. S/S REM❑VABLE� UNDERSHELF -NEMA 5-15R GFCI DUPLEX OUTLET (FOR COLD PAN) PRE -WIRED TO LOAD CENTER 120V 1PH 12,0 AMPS J-BOX FOR LIGHTS PRE -WIRED TO LOAD CENTER 120V 1PH 3.0 AMPS 90" ITEM #4 2 ITEM #3 HLS84 CLS90 HOT FOOD COLD FOOD COUNTER COUNTER HOT FOOD WELLS PRE -WIRED TO LOAD CENTER 208/10, 29.8 AMPS, LEI ITEM #4 HLS84 HOT FOOD COUNTER HOT FOOD COUNTER PL-1 LAMINATE END PANEL, TYP ITEM #3 MILK COOLER KEC ITEM QTY MANUFACTURER MODEL NO. DESCRIPTION P.O. NOTES 4A 6 6A 1 2 1 LOW TEMP HATCO WELLS DI-2075TA GRAH-36 MO0-500TDM/AF DROP -IN COLD FOOD WELL HEAT LAMPS DROP -IN HOT FOOD PAN MULTITERIA MULTITERIA MULTITERIA LOAD CENTER, 120/208V, 10, 120 AMP SERVICE 8" L-----J 34" I ---- -- --- 12" , —24"— ITEM #5 ULS24 UTILITY COUNTER V LIJ LT UTILITY COUNTER NEMA 5-15R GFCI DUPLEX AND SEPARATE DATA CABLING BOX W/5-15P & 8'-0° C❑RDSET 46" ITEM # 1 CS36 CASHIER COUNTER FY #4A HOT WELL 120/208V / 30A / 1F #4 HEAT LAMP 120V / 15A / 1PH #3A COLD WELL 120V / 15A / 1PH #3 LTGHTS 120V / 15A / 1PH #4 LIGHTS 120V / 15A / 1PH ITEM #5A INCOMING POWER 120/208V / 1PH / 60A Ll L2 46.1A 44.8A ��Q,SSIFj�� UL EPH ELECTRICAL LOAD CENTER/WIRING NOTE: EACH COUNTER IS PRE -WIRED TO ALL ELECTRICAL COMPONENTS IN THAT COUNTER WITH THE WIRES BUNDLED IN SEALTITE WITH EXTRA LENGTH TO REACH THE LOAD CENTER. AFTER COUNTERS ARE SET IN PLACE, THE ELECTRICIAN MUST PULL THE LENGTH OF WIRING THRU ADJACENT COUNTERS, LAYING WIRING IN U-CHANNEL UTILITY CHASE (SEE COUNTER SECTION VIEWS), CONNECTING TO THE LOAD CENTER IN COUNTER AS NOTED, WHERE ALL THE CIRCUIT BREAKERS ARE IDENTIFIED. THE ELECTRICIAN MUST HARD WIRE, PER LOCAL CODE, FROM THE POWER SOURCE DIRECTLY TO THE MAIN LUGS INSIDE THE LOAD CENTER. FSEC TO VERIFY ALL DELIVERY ACCESS WILL ACCOMMODATE COUNTER SIZES AS SHOWN. DOORS, ELEVATORS, HALLWAYS, LOADING DOCKS ETC MATERIAL/COLOR SELECTIONS: 1. COUNTERTOP: 14 GA. STAINLESS STEEL 2. FOOD SHIELD: STAINLESS STEEL FINISH 3. TRAY SLIDE: 16 GA. STAINLESS STEEL 4. PL-1 LAMINATE: V7953-38 HARVEST MAPLE BY WILSONAR T 5. KICK PLATE: STAINLESS STEEL FINISH 6. SIGNAGE OVERSTRUCTURE SUPPORT POSTS: STAINLESS STEEL 7. SIGNAGE OVERSTRUCTURE CANOPY: STAINLESS STEEL 8. GRAPHICS: CUSTOM GRAPHICS ARE REQUIRED... 9. GRAPHIC IMAGE FILES PROVIDED ""BY ARCHITECT"" TO BE IN A TIFF FILE, AT LEAST 150-300 DPI AT 100% SIZE PRINTED OUT IMAGE, OR VECTOR ART CREATED IN ILLUSTRATOR SAVED AS A PDF, Al OR EPS FILE MANUFACTURING NOTES: 1. 1" SQ. STAINLESS STEEL, WELDED TUBULAR FRAMEWORK 2. STANDARD ESSENCE CORNERS WITH REMOVABLE LAMINATE PANELS AND MOUNTING CHANNELS. 3. TRAY SLIDES TO BE ON FOLD -DOWN BRACKETS. 4. WORK LEDGE TO BE ON FOLD -DOWN BRACKETS. 5. TRAY SLIDES TO BE 3/8" SHORT OF COUNTER ENDS. 6. (3) INVERTED "V" RIDGES ON STAINLESS STEEL TRAY SLIDE. 7. 1-5/8" DIA. X 6"H STAINLESS STEEL LEGS WITH ADJUSTABLE BULLET FEET. 8. STAINLESS STEEL DOORS ON OPERATOR SIDE TO HAVE TWIST LATCH. REVISIONS CONFORMED SET MARCH 22, 2019 0 2-19-2019 BIDSUPPLEMENT I ® 2-22-2019 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N Phase 2 of 5 0 0 Wx NOW rr, f■i■i ..i rT� w � W O 0 LI i� RJS-+ ASSOCIATES _NTEGRATED FOOD SERVICE DESIGN P.O. BOX 370 14 HIGH STREET OLD LYM,E, CT 06371 T: 860.434.2700 F: 860.434.3735 vrvnv.psfsd.com PILO NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FOOD SERVICE EQUIPMENT MANUFACTURERS DETAILS -MULITITERIA z U N 0 ^L A z cA C DATE 11 /02/2018 COPYRIGHT Moser Pilon Nelson Architects GENERAL NOTES 1. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR OnOIKIK Eo OIo1KIf-- I AVnI IT AKIr) WVIIRAI II I(- ('.AI (`1 it ATION.q arr\14M L-1Ar,ruvvu-"vv, rlvvI,,� l-. --- TO MEET THE REQUIREMENTS OF NFPA #13. 2. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE WORK INSTALLATION DRAWINGS AND SUBMIT THEM TO THE ENGINEER AND RATING BUREAU FOR APPROVAL. SHOP DRAWING APPROVAL FROM THE AHJ IS REQUIRED PRIOR TO THE START OF SYSTEM INSTALLATION. 3. PROVIDE CALCULATION FOR LIGHT HAZARD SPRINKLER SYSTEM FOR REMOTE CLASSROOMS. 4. PIPING SHALL BE RUN CONCEALED THROUGHOUT FINISHED SPACES. REFER TO ARCHITECTUAL PLANS FOR CEILING TYPES, HEIGHTS AND CONSTRUCTION DETAILS. NOTE, WHERE UPRIGHT HEADS ARE SHOWN THERE IS TYPICALLY NO FINISHED CEILING. OX X.4 �Z BB DD FF HH f�HJ1 KK 1-1/2" DRAIN LINE ABOVE CEILING FROM FLOOR CONTROL ASSEMBLY DRAIN RISER TO DISCHARGE TO THE EXTERIOR AT GRADE ENGLISIjLEARNERS L VISUAL ARTS CLASSROOM 1 99 SPRINKLERS IN KILN ROOM SHALL BE HIGH TEMPERATURE CLASSIFICATION I\ O I OO I rya II s 4 +J — IR® I I 1 KILN® aASUALARTS STORAGE RO R Ff +1 �L GENERAL MUSIC 120 I INSTALL SEISMIC SEPARATION LOOP AT CFISMI(: STRI ICTI IRAI .InINT CORRIDOR MEDIA CENTER OFFICE 10a MEDIA CENTER WORKROOM `ft 04-d FIRE PROTECTION FIRST FLOOR - SOUTH 1 /8" = 1 1-0" FIRE PROTECTION LEGEND +—<=� FIRE PROTECTION PIPING (PROPOSED) + BUTTERFLY VALVE W/ TAMPER SWITCH FLOW SWITCH INSPECTOR'S TEST / SECTIONAL DRAIN VALVE FLOOR CONTROL ASSEMBLY - BUTTERFLY VALVE W/ FLOW SWITCH AND INSPECTOR'S TEST VALVE ® CONCEALED PENDENT SPRINKLER HEAD ® R RECESSED PENDENT SPRINKLER HEAD O UPRIGHT SPRINKLER HEAD OE PENDENT SPRINKLER HEAD W/ DEEP ESCUTCHEON d HORIZONTAL SIDEWALL SPRINKLER HEAD PP I QQ RR TT T�. GRADES 1-2 CLASSROOM 11381I I I I i I I TO DISCHARGE TO THE EXTERIOR AT GRADE I FIRE PROTECTION FIRST FLOOR - NORTH 1/8" = 1'-011 REVISIONS CONFORMED SET Syr A RCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE202 ROCKY miu, cT 06067 P.- (860) 436-4336 F. (860) 436-4450 www.rzdes,fgnassociates.com ��\\1111111f111//!//j COIV/V, W. Q 1 o� NO.25239 � MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 563-6164 TITLE FIRE PROTECTION FIRST FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. FP1*1 FIRE PROTECTION LEGEND r—c t FIRE PROTECTION PIPING (PROPOSED) OS&Y GATE VALVE W/ TAMPER SWITCH IY m DOUBLE CHECK VALVE BACKFLOW PREVENTER ® RISER CHECK VALVE FLUSH STYLE FIRE DEPARTMENT CONNECTION ELECTRIC ALARM BELL BACKFLOW PREVENTER TEST HEADER N CHECK VALVE BUTTERFLY VALVE W/ TAMPER SWITCH 0) CUNCCALLU NCNULN T SPRINKLER HEAD O R RECESSED PENDENT SPRINKLER HEAD O UPRIGHT SPRINKLER HEAD 0 E PENDENT SPRINKLER HEAD W/ DEEP ESCUTCHEON • D DRY PENDENT SPRINKLER HEAD MAl'VCI 111A! MMC%1CAtTCE) TCQT UMAMEM 6" FIRE PROTECTION WATER SEVICE Do o ©oa o o ®® ©® o 0 FIRE DEPARTMENT CONNECTION j AT 3+ FT ABOVE GRADE j I I I FIRE PROTECTION FIRST FLOOR - WEST 1/811= 11-011 0 o (4 KEYPLAN I GENERAL NOTES I 1. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER PIPING LAYOUT AND HYDRAULIC CALCULATIONS 12 — TO MEET THE REQUIREMENTS OF NFPA #13. — 13J 2. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE — WORK INSTALLATION DRAWINGS AND SUBMIT THEM TO THE 14 ENGINEER AND RATING BUREAU FOR APPROVAL. SHOP DRAWING APPROVAL FROM THE AHJ IS REQUIRED PRIOR I TO THE START OF SYSTEM INSTALLATION. 3. PROVIDE CALCULATIONS FOR LIGHT HAZARD SPRINKLER SYSTEMS FOR GYMNASIUM. 4. PROVIDE CALCULATIONS FOR ORDINARY HAZARD SPRINKLER SYSTEMS FOR MECHANICAL ROOM, KITCHEN AND STAGE. 15 5. THE LOCATION OF THE WATER SERVICE ENTRANCE, — BACKFLOW PREVENTER, FIRE PROTECTION RISERS, HOSE — 16 STATIONS AND TEST HEADER SHALL BE AS SHOWN. 6. PIPING SHALL BE RUN CONCEALED THROUGHOUT FINISHED SPACES. REFER TO ARCHITECTUAL PLANS FOR CEILING TYPES, HEIGHTS AND CONSTRUCTION DETAILS. NOTE, WHERE UPRIGHT HEADS ARE SHOWN THERE IS TYPICALLY NO FINISHED CEILING. I 17 2q 18 19 SOCIAL WORKER / I i 22 TOILET 929 cc ;. 33 34 C- - 39 REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pr (860) 43&4336 Fe (860) 436-4450 www.rzdesignassociafes.com ��✓,'PRD W. aNO. 25239 MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FIRE PROTECTION FIRST FLOOR PLAN - WEST DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. FP1o2 128 0 0 N a) E z U z a GENERAL NOTES I. I HE FIRE PRO i C1.. 1 IV1V VRISRESPR IJ RCJI"VNSIDDLE r^vR SPRINKLER PIPING LAYOUT AND HYDRAULIC CALCULATIONS TO MEET THE REQUIREMENTS OF NFPA #13. 2. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE WORK INSTALLATION DRAWINGS AND SUBMIT THEM TO THE ENGINEER AND RATING BUREAU FOR APPROVAL. SHOP DRAWING APPROVAL FROM THE AHJ IS REQUIRED PRIOR TO THE START OF SYSTEM INSTALLATION. 3. PROVIDE CALCULATION FOR LIGHT HAZARD SPRINKLER SYSTEM FOR REMnTF ri AgRROOMS, 4. PIPING SHALL BE RUN CONCEALED THROUGHOUT FINISHED SPACES. REFER TO ARCHITECTUAL PLANS FOR CEILING TYPES, HEIGHTS AND CONSTRUCTION DETAILS. NOTE, WHERE UPRIGHT HEADS ARE SHOWN THERE IS TYPICALLY NO FINISHED CEILING. FIRE PROTECTION LEGEND FIRE PROTECTION PIPING (PROPOSED) j7TG;1, n1 1T-rrn Cl v IIAI %fc IAlf TAKAO= CIAAT!`L! DUI IGRr-LT V/iLVC VV/ I ruvir-• L II VVV 11 %I 11 FLOW SWITCH i INSPECTOR'S TEST / SECTIONAL DRAIN VALVE m-,I� FLOOR CONTROL ASSEMBLY - BUTTERFLY VALVE W/ FLOW SWITCH AND INSPECTOR'S TEST VALVE w � r1rinlr'C41 Gr) DI=K1nr_KIT CDPIXIVI FP I-IFAn VVIYVL/'�- I LIYVL�. OR RECESSED PENDENT SPRINKLER HEAD O UPRIGHT SPRINKLER HEAD 0 E PENDENT SPRINKLER HEAD W/ DEEP ESCUTCHEON OX X.4 Z AA BB DD FF HH II�H KK PP Q RR O I I I I ! I ! I I ! FLOOR CONTROL ASSEMBLY SECOND FLOOR G I O ® I I ® 6 I— — — —fi — -- I — -- -- -- I-- —I 12 ! — — — — — CORRIDOR 13 F++I 14 Lu-J GRADES 3-5 I ® CLASSROOM ! -- _�-Hff- - -15 SOUTH STAIR � 16 � o I I I EEL-1 I I ! I I I I I ! � I I I I I I I I I ® ALCOVE I O I I I I I I I I I I ! I 2ILE04 T ®T IL T ! I I I 19 Ez R INSTRUCTIONAL R :7 4 L STORAGE 21 GEN RAZ STORAGE - — — — — — ° — ° — — r BOYS' TOILET ERE _ `- — — — rf +1 k7� I I I ! I I 0 I I I I 26 I I I I BREAK-OUT AREA 281 SPECIAL EDUCATION RESOURCE ROOM 1 GIRLS' TOILET 220 I � 9 ° 0 to _ 00 I O ! O EAST LOBBY I O I O O ! QO ! - O 11 � tj3 — t- —I --� — — — - I I I I I I I i I I I T I FIRE PROTECTION SECOND FLOOR — SOUTH 1 /811 = 1'-0" ----------------- I I I I 41 JJ1 I I I I I I rld I 1 FIRE PROTECTION SECOND FLOOR — NORTH FP1.3 1 /811 = 11-011 KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pr (860) 436-4336 Fa (860) 436.4450 www.rzdesignassociates.com 4 Ci V mq W. C "0�''' V� `� NO.25239 r� , Z7_t MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FIRE PROTECTION SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. FP193 m REVISIONS CONFORMED SET MARCH 22, 2019 it 1 / Z5 = i'-0 GENERAL NOTES 1. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER PIPING LAYOUT AND HYDRAULIC CALCULATIONS TO MEET THE REQUIREMENTS OF NFPA #13. 2, THE FIRE PROTECTION CONTRACTOR SHALL PREPARE WORK INSTALLATION DRAWINGS AND SUBMIT THEM TO THE ENGINEER AND RATING BUREAU FOR APPROVAL. SHOP DRAWING APPROVAL FROM THE AHJ IS REQUIRED PRIOR TO THE START OF SYSTEM INSTALLATION. 3. PROVIDE CALCULATION FOR LIGHT HAZARD RAW SPACE SPRINKLER SYSTEM PROTECTING UNFINISHED ROOMS. } a ® o } 3 Q o � 4 FIRE PROTECTION LEGEND L1- m0a pon-rcl-TInKi plol"I/'' _foononecrn I 11\L. rlllJ 1 L. ' 1 %-JIV F- rIVV kr rwrwoGvj O UPRIGHT SPRINKLER HEAD ® CONCEALED PENDENT SPRINKLER HEAD ® R RECESSED PENDENT SPRINKLER HEAD ® E PENDENT SPRINKLER HEAD W/ DEEP ESCUTCHEON O STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD mAm STREET SUITE 202 ROCKY HILL, Cr 06067 Pr (860) 436-4336 Fe (860) 436-4450 www.mdesignassociates,com ty N0.25239n MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE FIRE PROTECTION ALTERNATE 1 - ADDED CLASSROOMS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. FP L 4 21 1 1 REVISIONS CONFORMED SET MARCH 22, 2019 SPRINKLER SYSTEnn ZnnIE SERVING CAFETERIA, GYMNASIUM, ART AND MUSI_C_PROGRAM_S, AND MEDIA CENTER (SIZE PER HYDRAULIC CALCULA ION) FLOW SITCH - PIPE SADDLE MOUNT W/ADUSTABLE RETAI (REAR ALARM ZONE) SPRINKLER SYSTEM RISER TO FLOOR CONTROL VALVES I VIM IN STAIRWELL AT FRONT OF BUILDING (SIZE PER HYDRAULIC CALCULATION) INSPECTOR'S TEST CONNECTION - FLOOR CO LUNG F TO INCLUDE TEST VALVE' WITH 1/2" ORIFICE FLOOR CONTROL VALVE - AND SIGHT GLASS_. AND SECTIONAL DRAT VALVE _ INDICATING BUTTERFLY VALVE, BRONZE PIPE DRAIN TO 2" MAIN DRAIN LINE) BODY, STAINLESS STEEL DISC, RESILIENT ( REPLACEABLE SEAT; HANDWHEEL AND WELDED KNEE RACKET W/ GEAR DRIVE, W/ BUILT-IN TAMPER SWITCH U-BOLT - 2"x2"x19' ANGLE IRON FRAME TO SUPPORT TEST - MASTER ALARM FLOW SWITCH - HEADER LINE OFF OF WALL- PIPE SADDLE MOUNT W/ ADJUSTABLE RETARD SYSTEM VALVE - I RESILIENT WEDGE I,-,, SERVICE VALVE - SPRINKLER RISER ,CHECK VALVE - TEST HEADERMANIFOLD - RESILIENT WEDGE OS&Y GATE VALVE TWO-WAY DUCTIL P IRON OS&Y GATE VALVE -T� 0 _� GROOVED FLANGED -MAINTENANCE BODY END INLET W/ 3 N ALL VA ANCE PORT WV COCK BOLTED CAP FOR INSPECTION & `---- FURNISH W/ CHROME PLATED ESCUTCHEON TEST CO 15"x9" ENGRAVED 1 " MEDIUM BLOCK LETTERING (TYP. OF 4) SERVICING OF COMPOSITION DISC _ BACKFLOW PREVENTER'&'TEST HEADER' LOCATE WITH GOOD CLEARANCEFOR 2" MAIN DRAIN VALVE FROM ALL) (� YSTEM PRESSURE GAUGE o o O E GAUGE SUPPLY PRESSURE -- i � GE TAMPER SWITCH o 0 (TYP. OF 2) I I I BALL VALVE T ST COCK o SPRINKLER SYSTEM RISER VALVE - BALL A V �� EPDXY COATED DUCTILE IRON BODY BUTTERFLY ALVE, EDPM ENCA-P$ULATED DUCTILE IRON-6IS , TIE BOLT ° GEAR OPERATED WITH BUILT-IN TAMPER SWITCH (T-yP•) - - - _ - 2"_MAIN DRAIN LINE _ I BACKFLOW PIPE SADDLE W/ U-BOLT DOUBLE CHECK -VALVE BACKFLOW PREVENTE - ASSEMBLY _ ON 2-1/2' X 3" PIPE STAND 0" MtNXfF EPDXY COATED DUCTILE IRON BODY CHECK VALVES, 3 W/ THREADED ADJUSTER W/ REMOVABLE BROZE SEATS, STAINLESS STEEL INTERNAL ° (TYP. OF 2) PARTS AND tIGHT SEALING RUBBER CECK VALVE DISCS 00 -- SLIT RING EXTENSION CLAMP STAND (TYP.) 2" MAIN DRAIN PIPED TO EXTERIOR OF BUILDING TERMINATE W/ ELL AND ESCUTCHEON (PROVIDE SPLASH BLOCK) BALL VALVE - TWO PIECE BROZE BODY W/ TEFLON SEAL & PACKING (TYP.) 3/4" HARNESS RODS -- - (TYP.) DOUBLE BOLT UNDERGROUND SOCKET CLAMP (TYP-) 00 ANCHOR WATER SERVICE ENTRANCE FROM FINAL 900 BEND BACK TO PREVIOUS PIPE JOINT BELL ---- MECHANICAL JOINT DUCTILE IRON ELBOW 4" TEST HEADER VALVE - d- " FLOOR SINK - REFER TO EPDXY COATED DUCTILE IRON BODY BUTTERFLY VALVE, EDPM ENCAPSULATED DUCTILE IRON DISC, PLUMBING PLANS GEAR OPERATED WITH BUILT-IN TAMPER SWITCH d� BALL VALVES - PAIR OF VALVES TO DIVERT =° " DRAIN TO EXTERIOR FOR d ANNUAL MAIN DRAIN TEST d o MIN. 5'-0" ° COVER ° OVER PIPE I d - a ° 14. °-d- a° 4� 0 NEW 6" CLASS 52 DUCTILE IRON FIRE PROTECTION WATER SERVICE d - COORDINATE LOCATION NOTCH IN FOOTIING W/ SPACE FOR HARNESS RODS FOR FIRE PROTECTION WATER SERVICE TO PASS UNDER FOUNDATION 1 FIRE PROTECTION RISER DETAIL FP2.1 3/4" = V-0" LATERAL SEISMIC BRACE ANCHORED TO BUILDING #2 STRUCTURE FRAME ADJACEN I TO STRUCTURAL SEIMIC JOINT SPRING ISOLATOR - MANUFACTOUROR SHALL PROVIDE NFPA ADUSTABLE RING HANGER SUPPORTED FROM BUILDING #1 - LATERAL SEISMIC BRACE ANCHORED TO BUILDING #1 STRUCTURE FRAME ADJACENT TO STRUCTURAL SEIMIC JOINT PROVIDE LONGITUDINAL \ SEISMIC BRACE OF PIPE AT OR PRIOR TO CHANGEOF DIRECTION IN CONTINUATION OF SYSTEM FLEXIBLE EXPANSION LOOP - GROOVED END OR TREADED END EXPANSION ASSEMBLY AT LINE SIZE WITH PRESSURE LOSE ACCOUNTED FOR SUPPORT END OF EXPANSION IN APPROPRIATE HYDRAULIC CALACULATION (S) LOOP FROM EITHER STRUCTURE NOTES: 1. SEE ARCHITECTURAL AND/OR STRUCTURAL DRAWING FOR LOCATION OF SEISMIC JOINTS. 2. IN LIEU OF MANUFACTURED ASSEMBLY PROVIDE FLEXIBLE GOOVED COUPING ASSEMBLY OF NIPPLES AND ELBOWS REQUIRED TO ALLOW MOVEMENT IN SIX DIRECTIONS PER FIGURE IN NFPA #13 APPENDIX A. 3. BASED ON FIRELOOP BY THE METTRAFLEX COMPANY, OR EUAL PRODUCTS BY FLEX -HOSE INC. OR MASON -MERCER OR APPROVED EQUAL. r2 SEISMIC SEPARATION ASSEMBLY DETAIL NFPA ADUS I ABLE RING HANGER SUPPORT FROM BUILDING #2 -- PROVIDE LONGITUDINAL SEISMIC BRACE OF PIPE AT OR PRIOR TO CHANGE OF DIRECTION IN CONTINUATION OF SYSTEM FLOOR CONTROL VALVE - INDICATING BUTTERFLY OR BALL VALVE W/ BUILT-IN TAMPER SWITCH MILWAUKEE BUTTERBALL MODEL BB-SCS OR EQUAL BY NIBCO OR S.P. FITTINGS - PROVIDE FITTING AT TOP OF RISER FOR FLUSHING SYSTEM (GROOVED COUPING \ AND END CAP) PROVIDE CLEAN -OUT @ TOP OF 1-1/2" DRAIN RISER MIN. 1" SECTIONAL DRAIN L _-n Inlrrl I InG I rnnnnl ---- -.- 1V ItVVLV VL VIVIVtV NEW 4" SPRINKLER RISER - (I SIZE PER HYD. CAL.) ARM OVER - CEILING GRID --- SPRINKLER HEAD �j cQ �� cQ NTS - - SPRINKLER SYSTEM MAIN SIZED PER HYDRAULIC CALCULATION FLOW SWITCH - PIPE SADDLE MOUNT W/ ADJUSTABLE RETARD POTTER ELEC. MODEL VSR-F ANCHOR TO BUILDING STRUCTURAL ELEMENT WITH FASTENERS PER NFPA#13 REQUIREMENTS SWAY BRACE ATTACHMENT CLAMP ---- (FIG. 1000) 30° MIN FROM VERTIAL- ANCHOR TO BUILDING STRUCTURAL ELEMENT WITH FASTENERS PER NFPA#13REQUIREMENTS - SWIVEL SWAY BRACE FITTING (FIG. 980 OR FIG. 910) / 30° MIN FROM VFRTIA LATERAL SWAY BRACE - V OR 1-1/4" SCHEDULE 40 BLACK STEEL PIPE AS REQUIRED PER SEISMIC SWIVEL SWAY BRACE FITTING (FIG. 980 OR FIG. 910) LONGITUDINAL SWAY BRACE - 1" OR 1-1/4" SCHEDULE 40 BLACK STEEL PIPE AS REQUIRED PER SEISMIC LOADING LOADING SWIVEL SWAY BRACE FITTING (FIG. 910, FIG. 975 OR FIG. 980) \ PIPE CLAMP (FIG. 4 OR FIG. 4A) FIRE PROTECTION PIPING FIRE PROTECTION PIPING (STANDPIPE OR SPRINKLER MAIN) LATERAL BRACING LONGITUDINAL BRACING SWAY BRACE ATTACHMENT CLAMP ANCHOR TO BUILDING STRUCTURAL (FIG. 1000) \ ELEMENT WITH FASTENERS PER NFPA#13REQUIREMENTS ANCHOR TO BUILDING STRUCTURAL ELEMENT SPRINKLER MAIN OR OTHER PIPING WITH FASTENERS PER NFPA#13 REQUIREMENTS 30°MIN FROM O VERTICAL SWIVEL SWAY BRACE FITTING -- SWIVEL SWAY BRACE FITTING (FIG. 910 OR FIG. 980) (FIG. 980 OR FIG. 910) LONGITUDINAL SWAY BRACE - - LATERAL SWAY BRACE - 1" OR 1-114" SCHEDULE 40 1" OR 1-1/4" SCEDULE 40 BLACK STELL PIPE BLACK STEEL PIPE AS AS REQUIRED PER SEISMIC LOADING REQUIRED PER SEISMIC LOADING J r MAINTAIN SHORTEST POSSIBLE DISTANCE SWAY BRACE \ BETWEEN CENTER LINES ATTACHMENT CLAMP (FIG. 1000) COMBINED LATERAL AND LONGITUDINAL BRACING 3 PIPING SEISMIC RESTRAINT DETAILS F 2 NTS DETAIL 3 IS ONLY APPLICABLE TO DETAIL 2 INSPECTOR'S TEST CONNECTION TO INCLUDE TEST VALVE W/ 1/2" ORIFICE AND SIGHT GLASS, AND SECTIONAL DRAIN VALVE AFG Mfg. TESTanDRAIN MODEL 1000 INSPECTOR'S TEST CONNECTION AT NOT MORE THAN T-O" ABOVE FLOOR RUN TO EXTERIOR PER NOTES ON PLAN I -- LOCATE SPRINKLER RISER CLEAR OF REQUIRED EGRESS PATH IN STAIRWELL FLOOR CONTROL ASSEMBLY DETAIL - 2ND FLOOR NTS PERMISSIBLE HEAD LOCATION 6 SPRINKLER CENTERING DETAIL FP2.1 NTS NEW 4" SPRINKLER (TYP. - SIZE PER HYC FLOOR CONTROL VALVE - INDICATING BUTTERFLY OR BALL VALVE W/ BUILT-IN TAMP] MILWAUKEE BUTTERBALL MOE OR EQUAL BY NIBCO OR S.P. F PROVIDE FITTING A - RISER FOR FLUSHIN (GROOVED COUPIN( AND END CAP) MIN. 1" SECTIONAL I TO INCLUDE UNION GLOBE VALVE - BRONZE BODY, THREADED EN INTERRAL SEAT, SCREWED BC BRONZE DISC WITH NITRILE SI 17F P.qIn K1nN1_.gHnr.K (:nl n UAj d -1/1)" nOAIM DICCU 'EILING TO EXTERIOR i - SPRINKLER SYSTEM MAIN SIZED PER HYDRAULIC CALCULATION FLOW SWITCH - PIPE SADDLE MOUNT W/ ADJUSTABLE RETARD POTTER ELEC. MODEL VSR-F INSPECTOR'S TEST CONNECTION - TO INCLUDE TEST VALVE W/ 1/2" ORIFICE AND SIGHT GLASS, AND SECTIONAL DRAIN VALVE AFG Mfg. TESTanDRAIN MODEL 1000 VSPECTOR'S TEST CONNECTION AT NOT MORE THAN "-0" ABOVE FLOOR ELKHART BRASS FIG. 306 ADAPTER WITH FIG- 310 CAP AND CHAIN FLOOR CONTROL ASSEMBLY DETAIL - I ST FLOOR NTS LAWN ROAD SAWCUT TO PROVIDE EXISTING TOP SOIL &SEED IN BITUMINOUS EXISTING GRASS AREA - ---- UNDISTURBED SHELF PAVEMENT - PRIOR TO FINISHED PAVING - _,\ 1'-6" GRADE LEVEL I 2-1/2" o ° III—III—III-III-1 I —III -I I C—III-1 411 . y _ o 0 0 II }III III - ICI -III=III III= I=III I I-III-III-� -III III-1��-,�-� _ CONCRETE OR a RANDOM I II I II II I II ROLLED PROCESSED O LIMIT OF TRENCH GRAVEL I- BACKFILL II- I=I WALL CONSTRUCTION -- O EXCAVATION r COMPACTED CAULK ALL AROUND BOTH \ PACK ANNULAR SPACE SIDES W/ SEALANT THAT \ W/ MINERAL FIBER _ WILL REMAIN FLEXIBLE - --- o ! BANK RUN BANK RUN �, GRAVEL -III 3-0' MAX. - \\� GRAVEL CAULK ANNULAR SPACE AND / COMPACTED COMPACTED PROVIDE CHROME PLATED �, \ PERIMETER W/ A LISTED AND I I=I _ \\� APPROVED FIRESTOP SEALANT TO A MIN. OF IN 6 LAYERS ESCUTCHEONS FOR EXPOSED \ T-0' ABOVE I I\ PIPE \ PIPE IN FINISHED AREAS / FOR FIRE RATED WALLS �- TOP OF PIPE =III 15" MAX. I`-- 15" MAX. \ � % DIA. I �-I ---- MARKING TAPE 9 MIN. 9" MIN. \\\ --IM\ SLEEVE - (OPTIONAL -- SEE PROJECT DRAWING I -I / PEA STONE WHERE HOLE CORE -BORED FOR NUMBER AND SIZE UNDISTURBED EARTH - =I �=I ICI -=I I -III \jam BEDDING STD. WT. STEEL PIPE OF PIPING I -III -III III=) / TAMPED BY HAND DIA 1" LARGER THAN PIPE NEW D.I. WATER MAIN -� ��\��\\��\��\ RISER CLAMP ---,� -- 6" MIN. ABOVE UNDISTURBED BOLTS -- CAULK ALL AROUND TOP ROCK SURFACE FLOOR AND PERIMETER WITH/ ALl CONSTRUCTION-� FIRESDTOPDSEALANT EARTH 'FRENCH ROCK TRENCH d _ a.° d a NOTES: STEEL - STD. WT. `— PACK ANNULAR SPACE 1. REMOVE AND DISPOSE OF ALL ROCK EXCAVATION. SELECT SUITABLE STEEL PIPE DIA. 1" W/MINERAL FIBER BACKFILL FROM EXCAVATED MATERIALS. BACKFILL IN 12" LIFTS; LARGER THAN PIPE \ COMPACTION PER REQUIREMENTS OF SPECIFICATIONS SECTION 31 00 00. RISING 2" ABOVE -- PIPE - SEE PROJECT 2. PROVIDE METALLIC MARKING TAPE (0.35"THICK x 6"WIDE) AT A MIN. FINISHED FLOOR - DRAWING AND RISER DIAGRAMS OF 12" ABOVE TOP OF PIPE. TAPE TO BE BLUE, IMPRINTED WITH SPRINKLER REPEATING WARNING "CAUTION WATE LINE BURIED BELOW". BRANCH LINE TAPE TO BE RUN THE ENTIRE LENGTH. OR MAIN THROUGH -PENETRATION FIRE STOP SYSTEMS: (Based on HILTI FIRESTOP SYSTEMS) 1. GYPSUM WALL ASSEMBLY - 2Hr. FIRE RATED OR LESS - U.L. SYSTEM # WL1056 3. CONTRACTOR TO PROVIDE FOR DEWATERING OF THE TRENCH AS 2. CONCRETE BLOCK WALL - 3 Hr. FIRE RATED OR LESS - U.L. SYSTEM # CAJ1155 REQUIRED. THIS SHALL INCLUDE PUMPS, HOSES, BRACING, AND 3. CONCRETE FLOOR SLAB - 2Hr. FIRE RATED OR UNRATED - U.L. SYSTEM # CAJ1380 SHORING FOR PROTECTION OF PROPERTY AND SAFETY OF PERSONS. A. CONTRACTOR IS TO REMOVE ALL EQUIPMENT, BRACES, THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE U.L. LISTED FIRESTOP SYSTEM TO SHORING, ETC. BEFORE BACKFILLING. MATCH CONSTRUCTION AS NOTED OR OTHERS AS NEEDED. SUBMIT FOR APPROVAL. REFER TO ARCHITECTURAL PLANS AND DRAWINGS FOR LOCATION AND CONSTRUCTION OF B. ALL MATERIALS AND METHODS SHALL CONFORM WITH FIRE RATED WALLS AND PARTIONS. WATER COMPANY REGULATIONS AND STANDARDS FOR EXCAVATION AND INSTALLATION. PIPE PENETRATION DETAILS 8 PIPE TRENCH DETAIL FP2.1 NTS FP2.1 NTS STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pr (860) 436-4336 Fa (860) 436-4450 www.rzdesignassociates.com e q�..:�s,��Rp 92�.no .Or `� '0'. NO.25239 cC��l�� 1 � NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 5 6 3 - 6 1 6 4 TITLE FIRE PROTECTION DETAILS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. I� L=f o J� REVISIONS CONFORMED SET MARCH 22, 2019 ABBREVIATIONS A GENERAL SERVICE COMPRESSED AIR In it Inrvr:v DI IMD ,�."!"- I ' " 1 A/AMP AMPERE KEF KITCHEN EXHAUST FAN AC AIR COMPRESSOR KVA KILOVOLT AMPERE ACU AIR CONDITIONING UNIT(S) KW KILOWATT AD ACCESS DOOR KWH KITCHEN WATER HEATER AD AREA. DRAIN L LENGTH AFF ABOVE FINISHED FLOOR LA LABORATORY COMPRESSED AIK AFG ABOVE FINISHED GRADE LAV LAVATORY AHU AIR HANDLING UNIT LBS/HR POUNDS PER HOUR AMB AMBIENT LF LINEAR FEET ANSI AMERICAN NATIONAL STANDARDS INSTITUTE LG LABORATORY GAS APPROX APPROXIMATE LPC LOW PRESSURE CONDENSATE AS AIR SEPARATOR LIPS LOW PRESSURE STEAM AV ACID VENT (CHEMICAL) LV LABORATORY VACUUM AVTR ACID VENT THRU ROOF MA MEDICAL COMPRESSED AIR AW ACID WASTE MAGP MASTER ALARM GAS PANEL BFW BOILER FEED WATER MAX MBH MAXIMUM BTU PER HOUR (THOUSAND) BHP BRAKE HORSEPOWER MECH MECHANICAL BSMT RTI I BASEMENT BRITISH THERMAL UNITS MFR MANUFACTURER BTUH BRITISH THERMAL UNITS/HOUR MIN MPS MINIMUM MEDIUM PRESSURE STEAM C C/B CONNDNSATE CIRCUIT BREAKER MUAU MAKE UP AIR UNIT CER/CEG CEILING EXHAUST REG./GRILLE MV MEDICAL VACUUM CFM CUBIC FEET PER MINUTE N2 NITROGEN CFP CHEMICAL FEED PUMPS N20 NITROUS OXIDE CHWR CHILLED WATER RETURN N.C. NORMALLY CLOSED CHWS CHILLED WATER SUPPLY N.O. NORMALLY OPEN Cl CAST IRON N/A NOT APPLICABLE CLG CEILING NIC NOT IN CONTRACT CLPS CLEAN LOW PRESSURE STEAM NTS NOT TO SCALE CMPS CLEAN MEDIUM PRESSURE STEAM v OXYGEN CMV CEILING MOUNTED VENTILATOR OA OUTSIDE AIR CO CLEANOUT OD OUTSIDE DIAMETER CO2 CARBON DIOXIDE ORD OVERFLOW ROOF DRAIN COMP COMPRESSOR ORL OVERFLOW RAIN LEADER CID CONDENSATE PUMP P POLE CRU COMPUTER ROOM UNIT PH / O PHASE CT COOLING TOWER PRESS PRESSURE CU FT CUBIC FEET PRV PRESSURE REDUCING VALVE CUH CABINET UNIT HEATER PSI POUNDS PER SQUARE INCH CV COEFFICIENT, VALVE FLOW PVC POLYVINYL CHLORIDE Cvv C 0 L D VVA T ER QTY RD QUANTITY ROOF DRAIN D dB DEPTH DECIBEL REF ROOF EXHAUST FAN DC DIRECT CURRENT RM RO ROOM REVERSE OSMOSIS WATER DCV DE DOUBLE CHECK VALVE DEIONIZED PROCESS WATER RPD/RPZ REDUCED PRESSURE DEVICE DEG or' DEGREE RPM REVOLUTIONS PER MINUTE DI DISTILLED WATER RTU ROOF TOP UNIT DIA or O DIAMETER RV RADON VENT DN DOWN RL RAIN LEADER DWBP DOMESTIC WATER BOOSTER PUMP S SOIL DWG DRAWING SAC SHOP AIR COMPRESSOR EF EXHAUST FAN SCP STEAM CONDENSATE PUMP EFF EFFICIENCY SEP SEWAGE EJECTOR PUMP EHC rl I-rTOirAI uCATINIr_ (-API Gc CLCI, I R CAL 11EA INN ... SP SP STATIC PRESSURE SUMP PUMP ELEC ELECTRICAL SPEC SPECIFICATION ELEV ETP ELEVATOR ELECTRIC TRAP PRIMER SQ SQUARE EUH ELECTRIC UNIT HEATER SS SOIUSTACK EVAP EVAPORATOR ST STORM EWC ELECTRIC WATER COOLER STD STANDARD EWH ELECTRIC WATER HEATER SWH STEAM WATER HEATER EXH EXHAUST TAG IDENTIFICATION OF EQUIPMENT EXP EXPANSION TEMP TEMPERATURE F FAHRENHEIT TMV THERMOSTATIC MIXING VALVE FA FIRE ALARM TP TRAP PRIMER FCU FAN COIL UNIT TW TEMPERED VVA I ER FD FLOOR DRAIN TWR TEMPERED WATER RETURN FDC FIRE DEPARTMENT CONNECTION TYP TYPICAL FHC FIRE HOSE CABINET UH UNIT HEATER FM FLOW METER UR URINAL FP FIRE PUMP V VENT FPM FEET PER MINUTE VAC VACUUM FPS FEET PER SECOND VEL VFC VELOCITY VARIABLE FREQUENCY CONTROLLER FS FLOOR SINK VIF VERIFY IN FIELD FT FOOT OR FEET FVC FIRE VALVE CABINET VOL VOLUME G GAS VTR VENT THRU ROOF GA GAUGE W WASTE GAL GALLONS WC WATER CLOSET GND GROUND WG WH WIREGUARD WALL HYDRANT (HOSE BIBB) GPH GALLONS PER HOUR WHA WATER HAMMER ARRESTER GPM GALLONS PER MINUTE GRU GREASE RECOVERY UNIT WI WIDTH GW GREASE WASTE WP WEATHERPROOF I , HEIGHT W^-G WALL TRANSFER GRILLE HD HEAD WV WASTE AND VENT COMBINATION HMC HOT WATER MAINTENANCE CONTROLLER HP HORSEPOWER HPG HIGH PRESSURE GAS HPS HIGH PRESSURE STEAM HR HOUR(S) HT HEAT HTR HEATER HUM HUMIDIFIER HVAC HEATING, VENTILATION AND AIR CONDITIONING H\.Ar HOT WATER HWR HOT WATER RETURN HWRP HOT WATER RETURN PUMP HWS HOT WATER SUPPLY HX HEAT EXCHANGER ID INSIDE DIAMETER IEF IN -LINE EXHAUST FAN IN INCHES IN WG INCHES OF WATER, GAUGE (PRESSURE) IW INDIRECT WASTE PLUMBING SYMBOLS W WATER SERVICE COLD WATER -- HOT WATER HnT \ IATI=P PF(-IR('.I II ATIN(l -- — — — —- VENT S SOIL OR WASTE ABOVE GRADE S SOIL OR WASTE BURIED RV RADON VENT WV COMBINATION WASTE & VENT G GAS(NATURAUPROPANE) GW GREASE WASTE IW INDIRECT WASTE ORL OVERFLOW RAIN LEADER RL RAIN LEADER ST STORM DRAIN CD CONDENSATE DRAIN W WASTE ELECTRICAL HEATING CABLE ® WATER METER ASSEMBLY © GAS METER ASSEMBLY Q FLOOR DRAIN El FLOOR SINK O ROOF DRAIN 21 TRAP PRIMER ETP ELECTRONIC TRAP PRIMER FITTINGS AND VALVES PLUMBING GENERAL NOTES ®' BALL VALVE 1. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH CURRENT APPLICABLE CODES, ORDINANCES, THE RF(;I II ATnRY AGENCIES HAVING JURISDICTION AND THE SPECIFICATIONS. THE SPECIFICATIONS MAY EXCEED THE ► DIRECTION OF FLUID FLOW REQUIREMENTS OF THE CODE, IN WHICH CASE, THE SPECIFICATION MUST BE FOLLOWED. 4-. GATE VALVE 2. THE INTENT OF THESE DOCUMENTS IS FOR THE MEP TRADES TO FURNISH AND INSTALL COMPLETE MECHANICAL AND ELECTRICAL SYSTEMS. THE SPECIFIED PLUM131NG SYSTEM SHALL BE COMPLETE IN ALL RESPECTS; {---- BUTTERFLY VALVE OPERATIONAL, TESTED, ADJUSTED, APPROVED BY THE AUTHORITIES HAVING JURISDICTION AND READY FOR BENEFICIAL USE BY T HE nvVNER. ---1Ilf CALIBRATED BALANCING VALVE 3. THE TRADES SHALL OBTAIN AND REVIEW ALL CONTRACT DOCUMENTS BEFORE SUBMITTING A BID, INFORMATION IS GAS COCK PROVIDED ON THE VARIOUS DRAWINGS, SCHEDULES, SPECIFICATIONS AND ALL OF THE VARIOUS DOCUMENTS IN —��F--- CHECK VALVE THE BIDDING PACKAGE. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY AND FORM A TOTAL PROJECT DESIGN AND INFORMATION SOURCE FOR CONSTRUCTION PURPOSES. — �r-- PRESSURE REDUCING VALVE 4. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. COORDINATE LOCATIONS OF EQUIPMENT WITH OTHER TRADES BEFORE AND DURING �Ri-- THERMOSTATIC MIXING VALVE CONSTRUCTION. ANY MODIFICATION TO THE EQUIIPMENT LAYOUT, REQUIRED FOR INSTALLATION, IS TO BE S PERFORMED UNDER THE CONTRACT AGREEMENT, AT NO ADDITIONAL COST. REFER TOP DETAILS, SCHEDULES AND SOLENOID VALVE SPECIFICATIONS FOR ADDITIONAL INFORMATION. STATE PROJECT NO. DRAIN VALVE WITH HOSE END, CAP & 5. THE CONTRACTOR SHALL BECOME THOROUGHLY• FAMILIAR WITH THE PROJECT DOCUMENTS OF ALL TRADES. THE U IAIIKIl e% nnc nlAroAnAUTATIr Akin Qt4r)%A/ THE nENERAI ARRANGEMENT OF EQUIPMENT AND PIPING. THE 132-0089 N CHAIN OR HOSE BIBB DRAvvuvv� r,r« IJIi�VI\nIVIIVI/1I IV fIIVL/ Ld� CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF EQUIPMENT AND PIPING INSTALLATION WITH ALL THE PHASE 2 OF 5 --[f - WALL HYDRANT TRADES BEFORE COMMENCING WORK. 'J PIPE DROP WITH VALVE 6. EQUIPMENT SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS, WHEN EQUIPMENT MUST BE LOCATED ABOVE AN INACCESSIBLE CEILING (GYP BOARD OR EQUIVALENT), OR BEHIND A WALL, AN APPROPRIATE ACCESS DOOR SHALL TAKEOFF FROM TOP OF MAIN PIPE BE PROVIDED. IF AN ACCESS DOOR IS REQUIRED, IT SHALL BE OF A RATING APPROPRIATE FOR THE WALUCEILING IN WHICH IT IS TO BE INSTALLED. THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ACCESS PANELS FOR ALL TAKEOFF FROM BOTTOM OF MAIN PIPE VALVES AND DEVICES, REQUIRING ACCESS, WITH THE ARCHITECT, PRIOR TO INSTALLATION OF SUCH DEVICES OR OTHER APPURTENANCES. --�� -- UNION 7 AAII-IERE A CONFLICT OCCURS BETWEEN THE DOCUMENTS, IT SHALL BE BROUGHT TO THE ATTENTION OF THE PIPE ELBOW UP OR PIPE TEE UP ARCHITECT. CARRY AS PART OF THE BID THE LARGER QUANTITY AND/OR MORE EXPENSIVE IEM(S). PIPE ELBOW DOWN 8. THIS CONTRACT SHALL INCLUDE ALL THE NECESSARY PIPING, FITTINGS, TRANSITIONS, OFFSETS, ETC. AS REQUIRED TO INSTALL PIPING, EQUIPMENT, MAINTAINING PROPER CLEARANCES AND TO AVOID ANY CONFLICTS WITH OTHER TRADES, AND THE BUILDING STRUCTURE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY PIPE TEE DOWN ASSUMPTIONS, OMISSIONS OR ERRORS HE MAKES AS A RESULT OF HIS FAILURE TO COORDINATE WITH OTHER TRADES OR BECOME FULLY FAMILIAR WITH THE PROJECT DOCUMENTS OF ALL TRADES. WALL CLEANOUT OR BLIND FLANGE FLOOR CLEANOUT 9. DO NOT INSTALL ANY PIPING OVER ELECTRICAL PANELS, TRANSFORMERS, SPECIAL EQUIPMENT, OR THROUGH ELECTRICAL ROOMS, DATA ROOMS, ELEVATOR MACHINE ROOM, STAIRWELL OR STAIRWELL WALLS THAT ARE NOT ASSOCIATED WITH OR SERVE THE RESPECTIVE ROOMS. COORDINATE THE LOCATION OF ELECTRICAL EQUIPMENT "P" TRAP IN THE FIELD AND ADJUST AS NECESSARY. STRAINER OR STRAINER WITH BLOW- 10. IT IS NOT THE INTENT OF THE DRAWINGS TO SHOW INDIVIDUAL BRANCH PIPING TO EACH PLUMBING FIXTURE; ONLY I SE END, CAP AND CHAIN DOWN VALVE HOSE THE BRANCH PIPING TO GROUPS OF FIXTURES IS INDICATED. EACH AND EVERY FIXTURE SHALL BE PROPERLY PIPED TO WATER, WASTE, AND VENT PIPING SYSTEMS. REFER TO THE PLUMBING SCHEDULES FOR INDIVIDUAL PIPE BACKFLOW PREVENTER SIZES TO EACH FIXTURE. 11. PROVIDE PROPER PIPING SYSTEM IDENTIFICATION LABELS, SLOPES FOR DRAIN PIPING, CLEANOUTS, HANGERS, �---- PUMP ETC. IN ACCORDANCE WITH THE PLUMBING CODE. RAL DRAWINGS FOR. THE EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING z WATER HAMMER ARRESTOR 12. REFER TO THE ARCHITECTURAL � FIXTURES OR EQUIPMENT. ALL SUCH EQUIPMENT AND EQUIPMENT COLORS AND FINISHES SHALL BE COORDINATED I �� PIPE CAP OR CAPPED END OF PIPE WITH THE ARCHITECT. MOUNTING HEIGHTS SHALL BE APPROVED BY THE ARCHITECT.ORO _Zdl,.. nl .,rawln rnl vee ICI I Icu VA /PC Cnl F-Nnln \/AI VFS- l h � -= PIPE SLEEVE 13. INSTALL WATER HAMMER ARRESTORS (WHA) AT ALL QUICK C�U0-uvv V/1LV LJ II LII - - --. -- ETC.); SIZE SHALL BE BASED ON FIXTURE UNITS IPER PDI STANDARDS AND INSTALLED PER MANUFACTURER'S II x,. = PIPE GUIDES RECOMMENDATION. l Q AIR VENT 14. ALL PIPING, DRAINS, STRAINERS, FAUCETS, FAUCET AERATORS, FILTERS, ETC. SHALL BE THOROUGHLY CLEANED AND FLUSHED IMMEDIATELY BEFORE PROJECT COMPLETION. PROVIDE CERTIFICATION ON CONTRACTORS LETTER HEAD THAT THIS WORK HAS BEEN COMPLETED. PRESSURE RELIEF SAFETY VALVE [� 15. DOMESTIC WATER DROPS AND RISERS INSTALLED IN EXTERIOR WALLS SHALL BE INSTALLED ON THE WARM SIDE P�9 ---�Ar --I--- AQUASTAT OF INSULATION AND THE LOCATION SHALL BE MADE INFILTRATION FREE. �, .1r,nE:InI A_rG -ruG AA/nP]kl %AIITW rnA►NF=R FI I►�NISHED EQUIPMENT, INCLUDING REQUIRED "16. BEFORE INSTAUL A� I ION, �.vvr�uuvn l l_ I I IL v . 11" d � � , . � T TEMPERATURE SENSOR WITH SEPARABLE SERVICE CONNECTIONS, FACTORY START UPS AND INSTALLATION OF FIELD DEVICES. l SOCKET IN IMMERSIBLE WELL (T 17. PIPE ALL CONDENSATE DRAINS FROM MECHANICAL EQUIPMENT COOLING COILS, BY GRAVITY (INTERIOR AIR T TEMPERATURE GAUGE WITH SEPARABLE HANDLING UNITS, FAN COIL UNITS, AC UNITS, ETC.) TO FLOOR DRAINS, JANITOR'S SINKS OR OTHER APPROVED SOCKET IN IMMERSIBLE WELL LOCATION THROUGH AN AIR GAP. EACH CONDENSATE DRAIN SHALL BE TRAPPED AT THE EQUIPMENT DRAIN 4 i OUTLET, REFER TO TRAP DETAILS ON DRAWINGS. COORDINATE EXACT LOCATION OF EQUIPMENT WITH THE HVAC THERMOMETER WITH SEPARABLE CONTRACTOR AND ADJUST AS NECESSARY.�j `� SOCKET IN IMMERSIBLE WELL Q P 18. INSULATE ALL WASTE ABOVE SLAB RECEIVING CONDENSATE FROM EQUIPMENT INCLUDING "" TRAPS AND BRANCH y PRESSURE GAUGE WASTE PIPING FLEXIBLE CONNECTOR 19. ALL INDIRECT WASTE DRAINS SHALL BE PIPED TO FLOOR DRAINS, FUNNELS OR FIXED AIR GAP FITTINGS, THROUGH AIR GAP OR TO A SINK DRAIN TAILPIECE. 20. INSTALL TRAP PRIMERS OR TRAP GUARD SEALER FOR FLOOR DRAINS, HUB DRAINS AND FIXED AIR GAP FITTINGS, I WHERE TRAP IS SUBJECT TO LOSS OF SEAL BY EVAPORATION, CONNECT TRAP PRIMER TO COLD WATER LINE. PROVIDE ISOLATION VALVES AND EXTEND SLOPED PRIMING LINE TO DRAIN TRAPS. 21. COORDINATE ALL PLUMBING EQUIPMENT REQUIRING POWER, FOR EXACT LOCATION AND POWER REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 22. ALL EXTERIOR EXPOSED GAS PIPING SHALL BE PRIMED AND PAINTED. 23. FLOOR MOUNTED PLUMBING EQUIPMENT SHALL BE INSTALLED ON A 6" CONCRETE HOUSE -KEEPING PAD. COORDINATE SIZE AND FINAL LOCATION OF ALL CONCRETE PADS WITH THE STRUCTURAL ENGINEER. PADS SHALL BE MINIMUM 6" LARGER THAN THE EQUIPMENT IN BOTH HORIZONTAL DIRECTIONS. 24. COORDINATE EXACT LOCATION OF PLUMBING SERVICES ENTERING THE BUILDING WITH THE SITE CONTRACTOR AND UTILITY DRAWINGS PRIOR TO INSTALLATION. COORDINATE ALL FOUNDATION WALL PENETRATIONS AND INVERT ELEVATIONS WITH THE GENERAL CONTRACTOR AND/OR CONSTRUCTION MANAGER BEFORE COMMENCING v110RK. 25. SEISMICALLY SUPPORT THE EQUIPMENT AS REQUIRED BY CODE, THE AUTHORITY HAVING JURISDICTION, AND/OR AS SPECIFIED. SUBMIT ENGINEERED INSTALLATION DETAILS PER THE SPECIFICATIONS. THE CONTRACTOR'S SEISMIC ENGINEER SHALL REVIEW THE INSTALLATION AND PROVIDE A DETAILED REPORT FOR THE RECORD. 26. PROVIDE PIPE EXPANSION COMPENSATION FOR THE VARIOUS PIPING SYSTEMS. SUBMIT ENGINEERED DETAILS FOR APPROVAL AND VERIFY INSTALLATION IS IN ACCORDANCE WITH THE CODE. THE CONTRACTOR'S CONSULTING ENGINEER SHALL REVIEW THE INSTALLATION AND PROVIDE A REPORT OF THE FINDINGS. NECHAN/CAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 F: (860) 436-4450 www rzdesignassOCiates.00m C���� 37 u 25239 n !.L M0DSER P -1 L 0 N, NELSO'N ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PLUMBING GENERAL NOTES, ABBREVIATIONS AND SYMBOLS DATE 11 /2/201 S COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 0 0 N L m E z U N 0 a z a O O X .4 OZ BB DD HH KK PP Q RR TT UU I ! I I I I I I I I F.F. ELEV. I I I 318.25' 7IN L41411 T1 4nSffV- M #1 I I I I I I I I I I I I I I I II { I I I I I I ICI I I I;► P FCO- -4 „S 2 V P I r� TOO FD I I I I I L - I I 17 4+J co IL 'S. UP I J I FCO I o I I� 19 11 - - - _ - - - -�-- - I N SINK. K: -�- I � 611ST 20 "W. DN I 3"w 6" L. UP v2°v. UP F L - L L - - �I i/2"dt1. UP - �-�- - -�-; 6"RL. UP l I - - - - - - - - - - -- - { 4„ .. up � 25 FCO ,•5� _ - 1/2' W. P 14"S 4 S I FCO I I I FCO I I 26 � I I I 1 1/2 I 4 8. UP UP F.F. ELEV. - - I I - I "' 4"S 4" S 4"S FCO 1 1/2"W. UP F_ 17 %-T r F_ 1 i 4 I -- - - - -- -- - ----- - m----- - ---- -- -- - -I- -� _ _ - -- ---- ------ - ---- i- - FIXED ASK UAH i t I I 6"ST I 1 1/2"W. UP Ll 6"RL. UP I- L_ 3"W 3"w cn FCO I L_ I zo I I, 1/ "W. UP TO FIXED P L I AIR GAP - -- - - -r -- I - F� -- I` 4ST IL,LI �s\� 4S. II ! I I FCOI I I - bo �� I r-�w■nr-��Iw��r�,��. I .li� � � - 2 PLUMBING UNDERSLAB - SOUTH PU1.1 1/811 = 11-011 -- - REFER T -j I _ �- -I- -- --4- u1j- - �-- o---� --- -- L I I I FCO I I I I F.F. ELEV. 318,25' I I I I I i I 2"W. UP 2 UP 1 1/2"W. UP 3 Wes' o � I o -1 1/2"W. UP 1 1/2"W. UP 1 /2' P TO I FI E I GAP I o�-4"g 4"S 4"S 4"S � FCO 4"S. UP r4FCO k 4 - ��- - - _ I 0 - - L I 12W. P 2"W. U 4"S. UP 2 W. UP I I I I � 4"RI UP st�T FCO I I I I 2' UP I i i I 2" V UP 2"W]UP--\ 4'S UP L 4"S. Up +lo I L I -- -- - - I -I - 6 3"W 4"S - --4„S 3"W 2"W. UP L ❑� FCO FCO I II I -k !ejI I III I I I li ILLI I II I 1 1/2"Vil. UP- 1 1/2 W. UP F.F. ELEV. I I I I 11 318.25' III 1 1/2 UP 3"W S'W 1 1/2 W. UP J I 3W 3w 4"RL J1I _ - 4"RL UP FCO I I {- --- 4"ST - J 4"ST 6"ST I I I I I I FCO I r� 2"W. U 4'iS1 UP 4"S. UP 2"W. UP 44 2"VUP - - _- - I - . p I I KEYPLAN I I I I FCO < 3"W 4"S 4 S 3"W FCO 1 1/2"W. UP TO 1 1/2"W. UP TO I I FIXED AIR GAP FIXED AIR GAP II I I I I I 11 I I 3"W 3"W I I I I ' 1 1/2"W. UP 1 1/2"W. UP I I I FCO ° � I II I I I -1 1/2"W. UP j W L 3"W II I i I I I I I I 1 1/2"W. UP I I FCO I I I I I i 6"RL UP 4 4J\ I I I I I I r++1� I I Lu_j I L�'J � J! 4„RV. UP j � I 4" SCHEDULE 40 PVC RADON PIPING DOWN TO RADON I I I i I I I I L ---- J I I III PIT LOCATED BELOW SLAB. SLOPE PIPE 1/8" PER FOOT I 1 1/2"V . UP 1 - 1/2 „ UP W. TO SUCTION POINT. SEE DETAIL ON DWG. #P4.2. I FOR PIT SIZE AND CONSTRUCTION DETAILS 3"W- -3"W I I REFER TO STRUCTURAL DRAWINGS. I 1 1/2"W. UP 1 1/2„W. U P I I I I I 11 I II I II I I it I 11 I I I I I i I 4S FCO FCC 3"W 3"W 31 I Q� r 3 W- tJP J 2"W. UP 2W. UP < TO 4"S. UP - 4"S. UP I I; FIXED I INV. 314.73' _ _ _ _ - -AlR -GAP 1 1/2"W. UP 1 1/2"W. UP 3"W- -3" 6 ST 8' ST� FCO FCO - - 1 1/2"W] �P I \ L i W_ 6"RL UP 8"ST 4+I �- g° BURIED STORM I i �� I I r 3W � I REFER TO SITE UTILITY PLAN rf i, �r 1 1/2"W., UP F.F. ELEV. l ill 318.25' I I 11 I I 11/2"W.IUP 13 - -I--- 4"S - - - - - - - � -- -- 1--- I I I I II II I \` 14 I I 1 L 4„S FCO "UPI � Ly 1 1/2"W. UP I I � I 1 PLUMBING UNDERSLAB - NORTH PU1.1 1/811 = 11-011 REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 F. (860) 436-4450 www.rzdesignassociates.com 10�+ ' r N0.25239 MOSER ON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 563-6164 TITLE PLUMBING UNDERSLAB PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. Pulol KEYPLAN � � F P R T ` ^J `=J O i I I I I I I I I I I II II I I I� �I I III IL --- -� �--------�- —1—------� I—I�— S�-L— -----� I - _ o UP _ I .0 ni iotCn CAAIITARY REFER TO SITE UTILITY PLAN Ij I I I I I f —INV. 316.57 ' I I d- 21 UP 319.58'EV. I M- FCO -- - -�- -- ()FCO --- - 1 1/2"W. UP TO --- - - - 0 I it I I F F E_I_EV. FIXED AIR GAP I I I I i I 321.58'- FC 31 W 6'*_ U - I \ FCO �- -� 3"W 3 W co I I I L- I PROVIDE PIPE SLEEVE I FCO 40 I I F.F.IELEV. ` _77 - I 6"RL. UP ,. SE WASTE II '� I I I I I I I I I — - � _ -- — i 3" BURIED GREASE VENT 4 BURIED GREA FROM GREASE INTERCEPTOR TO GREASE INTERCEPTOR- - - J-- REFER' --TO SITE UTILITY PLAN REFER TO SITE UTILITY PLAN RE 4" BURIED SANITARY - I SITE UTILITY PLAN ` I - _ I _ - _ - - - - - - - - 21 REFER TO I —� GAS MAIN UP TO GAS 2"V. UP Nr o METER ASSEMBLY - - - AMAt 1 ID - - - - - — — — -- M - - — UP -- - -- cn Y ��. �,� (� INV. 316.9t5' - - _- - INV. 316.20 TO FD Zh - BURIED GAS SERVICE BY GAS CO. - - �_ _ I - REFER TO SITE UTILITY PLAN - _ -1 1- �-- - - - 24 —J — — — _ - _ 3"W. UP TO — - -- —t _ — — — — _ _ FCO " rp —_ —� " _ —� — — — -JAL . Stl�tK _ __ = J = — — — — — — — — _9 8' V — -- ----- � — — � F.F.FELEV. � 25 - - � _ _ P 319.58 - - 4"W. UP_- _ - - 1 1/2 -J - - W. U . 1 I - __ FCO TO FD FCO I - - - v I I 3„W - - 2"V. UP I /� 4"S 3"W FCO - --- - - - ff S - —J 4, S - - I i M I` (f) i ii� "vv. UP T O —_ — I — 4"W. UP I FIXED AIR GAP TO FD_F.F. ELEV. I-------------- �---w FCO 31 .58� _ - �FC°O3�� 4"CW UP TO- 4"DOMESTIC WATER SERVICE WATER METER I REFER TO SITE UTILITY PLAN - ASSEMBLY I 29 6' RL. UP 5-0' BELOW FINISHED GRADE - I L 2"W. UP PROVIDE PIPE SLEEVE Ir - L ' I ----�--- FCO °-1, - --- --- I 6,�RL. UP 411S. UP I M ;> Od FCO C� J --�- --- - 4°WV I I I I 2 w. UP -, 6"ST _ -- - - - 6 RL U - - � 3 WV �' v � .'W. UP - - - 6' RL. UP - 1 1/2' 1N:. UP FCO 3"WV FCO- - 11 1/2"W. UP TO 34 - — TO FD I 4 SUP -" FCO FCO �'' I - 1 1/2 W. UP I I FIXED AIR GAP I -� T - FCO 00 1 1/2"W. UP - �,� ! L7 I I o��n� 4"G�' `\ I I 1 1/2"W. UP I I I r co 4"RL. UP „ FCO vv-FCO �/ "TOf, D W. P 1 1/2"W. UP I ' r I �1 1/2 V. UP -� -- -- - - -�- -- -'� 1/4 UP FCO I I I I InI co 1 1/2"W. UP 2..W. UP �� 1 ia."Cw- UP L- -r -- - -- - FCO b\ 4"GW� - - - FCO -------- I (D TO F D I- -r- - M I - I J L- - - - - -'I I (I 3 WV- I ��� I F.F. ELro,EV. 1 �� TO DP FCOG� I I 319.58'Gv I Sly.ao 1 v� vv. yr „ I — i II FCO I 2"W'I i i I I �. I i I I i �, i n ii - 4"Gw. UP ih I I I 1 1/2'W. UP - g"}/�1 - - b PROVIDE PIP i I t I TO FS F_ _ - - 8"ST _ - — — 8' ST FCO I ' I � CO � SLEEVE FCO I I I I 1 1/2"W. UP I I I _ I I -� FCO - - - - -�- ---L— II I� �l ---! -----I _ -- - —INV. 2"W. P I - 8" BURIED STORM I 8" BURIED STO I I REFER TO SITE UTILITY PLAN -' REFER TO SITE ILITY PLAN 1 PLUMBING UNDERSLAB - WEST PU1.2 1/811 = 11-011 REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 a 0 0 v o � Q U 00*0 a�z � o O � a a a MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT06067 Pr (960) 4364336 I Fa (660) 436-4450 www.rzdesignassociates-cOin NO.252 ��� MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PLUMBING UNDERSLAB PLAN - WEST DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architect: 0 0 N t` E 73 z t U 0) .O ^L LL Z LL DWG. NO. PU1.2 — 6"RL DN. I J-I to . MEDIA CENTER OFFICE A94 VIDEO PRODUCTION LAB , MEDIA CENTER WORKROOM ® 1 PLUMBING DRAWING KEY NOTES 1O4"S DN., 2"V UP, 1 1/2"CW & 1/2"HW DROP TO WATER CLOSET AND LAVATORY. _ _..._ _ .... ��� . , .....r� n r r�rn 0' ,,,,,'A. 13 REFRIGERATOR: 1/2"CW DROP FURNISH AND INSTALL SIOUX CHIEF #696 ICE MAKER OUTLET SUPPLY BOX WITH SHUT OFF VALVE AND WATER HAMMER MAKER PROVIDE WA I ER HAMMER ARRr-0 1 um kwnri) - - ARRESTOR. PROVIDE 1/4" COOPER LINE LONG ENOUGH TO EXTEND TO THE 2O 1 1/4"CW AND 1/2"HW DROP TO WATER CLOSET AND LAVATORY. PROVIDE FRONT OF THE REFRIGERATOR. SEE CUTS FOR ROUGHING. WATER HAMMER ARRESTORS (WHA). 14 HOT WATER MAINTENANCE CONTROLLER. COORDINATE POWER WITH 3O 1 1/2"W DN., 1 1 /2"V, 1/2"H&CW DROP IN WALL TO SINK. ELECTRICAL CONTRACTOR IN THE FIELD. SEE GENERAL DETAIL ON DWG. #P4.1 O1 1/2"W DN., 1 1 /2"V UP, 1/2"H&CW DROP IN WALL TO SINK WITH BUBBLER. PROVIDE SEPARATE P-TRAPS FOR EACH BOWL AND SUPPLIES WITH STOPS 15 FLOW ACTIVATED TRAP PRIMER VALVE FOR CONDENSATE DRAIN FIXED AIR FOR FAUCET AND BUBBLER. GAP FITTING. INSTALL ON 1/2"CW LINE TO PLUMBING FIXTURE. SEE TRAP PRIMER DETAIL ON DWG. #P4.1 O CONNECT RAIN LEADER (RL) AND OVERFLOW RAIN LEADER (ORL) TO 16 FLOW ACTIVATED TRAP PRIMER VALVE FOR FLOOR DRAIN. INSTALL ON BI-FUNCTIONAL ROOF DRAIN. 1/2"CW LINE TO PLUMBING FIXTURE. EXTEND PRIMING LINE BELOW SLAB TO n U i..,rr.r� ��n11]AIAI LEADER inol \ -rLiDnl Ir-W I=YTr-RInR 11UA1 I PIPE OVERFI-VVV RAIN LEADER wr\Lj 11 uwvvl I �....w.. ••..-- FLOOR DRAIN. SEE TRAP PRIMER DETAIL ON DWG. #P4.1 APPROXIMATELY 18" ABOVE GRADE AND TERMINATE WITH OVERFLOW DOWNSPOUT NOZZLE (ODN) WITH BIRD SCREEN. COORDINATE WITH 17 PROVIDE HOT WATER TEMPERATURE MAINTENANCE CABLE. INSTALL ON ARCHITECTURAL ELEVATIONS. DOMESTIC HOT WATER SUPPLY BRANCH TO PUBLIC LAVATORIES WITHIN 2 FEET OF FIXTURE CONNECTION. O7 3/4'CW DROP TO EXTERIOR WALL HYDRANT ON WARM SIDE OF BUILDING INSULATION. 18 O 1 1/2"W DN., 1 1 !2"V, 3/4"H&CW TO SINK WITH EYE WASH. SEE DETAIL ON DWG #P4.2. O8 3/4"CONDENSATE TO FCU. CONNECT CONDENSATE TO FCU INTEGRAL CONDENSATE PUMP. COORDINATE POINT OF CONNECTION IN THE FIELD 1 g PROVIDE EXPANSION LOOP EQUAL TO METRAFLEX "METRA LOOP". PROVIDE WITH HVAC CONTRACTOR AND ADJUST AS REQUIRED. ANCHORS AND GUIDES PER MANUFACTURER'S RECOMMENDATION (TYPICAL) SEE NOTE 20 TO REFER TO SEISMIC JOINTS. O 1"CONDENSATE DROP TO FIXED AIR GAP FITTING. INSTALL FLOW ACTIVATED TRAP PRIMER VALVE. SEE DETAIL ON DWG. #P4.1 #10 20 ALL PIPING CROSSING SEISMIC JOINTS SHALL ACCOMMODATE DIFFERENTIAL MOTION. REFER TO SPECIFICATION FOR ADDITIONAL INFORMATION. SEE 10 1"CONDENSATE DROP IN WALL TO JANITOR SINK. TERMINATE 6" ABOVE SINK ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR LOCATIONS. RIM. 21 1"CW DROP TO WATER CLOSET AND 1/2"H&CW DROPS TO LAVATORY. 11 1 1/2"W DN., 1 1 /2"V, 1/2"CW DROP TO ELECTRIC WATER COOLER WITH PROVIDE WATER HAMMER ARRESTORS (WHA). BOTTLE FILLER. 12 3"W DN., 1 1/2"V, 1/2"H&CW DROP TO JANITOR SINK. n AAA n FF HH �iH KK IU PP I I I I I 16 AIDING IVENTION I I I I — "VUPI n - 22 I —L 23 ODN) — (1) } 41'ORL D�0 25 41'S. DNi I 26 I 4"ORL UP I � 29 I I 33 34 I I I I I I I I -I I 41 I I I - 46 I I I 2" V 2" V OFFSET AA ,� BB DD FF HH f IEH KK PP RR TT T UU i I i ODN a 2-15 ('J KEYPLAN 2" V 1 112"W. DN 2" V OFFS 3 REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE202 ROCKY HILL, Cr 06067 Pr (860) 436.4336 F; (860) 436-4450 www.mdesignassociates.Com `z 'sue NO.2523.9 /I MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD. CT. 06109 (860) 563-6164 TITLE PLUMBING FIRST FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 2 PLUMBING FIRST FLOOR - SOUTH P1.1 1/811= 11-011 1 PLUMBING FIRST FLOOR - NORTH P1.1 1/811= 1'-011 I Q 0 0 L: a) -0 E z U N O L 11 z PLUMBING DRAWING KEY NOTES O DOMESTIC HOT WATER SYSTEM (GAS HEATERS, EXPANSION TANK (ET), HI -LOW THERMOSTATIC MIXING 16 FLOW ACTIVATED TRAP PRIMER VALVE FOR FLOOR DRAIN. INSTALL ON 1/2"CW LINE TO PLUMBING VALVE (TMV) AND HOT WATER RETURN PUMP (HWRP). SEE WATER HEATER SCHEMATIC PIPING DIAGRAM FIXTURE. EXTEND PRIMING LINE BELOW SLAB TO FLOOR DRAIN. SEE TRAP PRIMER DETAIL ON ON DWG.#P3.1 FOR ADDITIONAL SCOPE OF WORK AND PIPE SIZES. DWG. #P4.1 O 2 1/2"GAS DROP WITH GAS VALVE TO EACH BOILER (392 MBH). VERIFY LOCATION OF CONNECTION POINT IN 17 SOLID INTERCEPTOR. REFER TO ARCHITECTURAL Al SERIES MILLWORK DETAILS FOR SOLID THE FIELD AND ADJUST AS NECESSARY. PROVIDE DIRT LEG. SEE DE TAIL ON DWG. #P4A. INTERCEPTOR LOCATION WITHIN CABINET. O 2"GAS DROP WITH GAS VALVE TO EACH WATER HEATER (199 MBH). VERIFY LOCATION POINT CONNECTION 18 1/2"CW DROP TO ELECTRONIC TRAP PRIMER VALVE FOR FLOOR DRAINS IN MECHANICAL ROOM IN THE FIELD AND ADJUST AS NECESSARY. PROVIDE DIRT LEG. SEE DETAIL ON DWG. #P4.1. AND OUTDOOR STORAGE. EXTEND PRIMING LINE BELOW SLAB TO FLOOR DRAINS. SEE TRAP DETAIL ON DWG. #P4.1 OPRIMER 4 3/4"CW. MAKE-UP WITH BACKFLOW PREVENTER RPZ FOR HVAC SYSTEM. COORDINATE LOCATION IN THE FIELD WITH THE HVAC CONTRACTOR, SEE RPZ INSTALLATION DETAIL ON DWG. #P4.1 19 3"W DN., 1 1/2"V, 1/2"H&CW DROP TO JANITOR SINK. O CONNECT RAIN LEADER (RL) AND OVERFLOW RAIN LEADER (ORL) TO BI-FUNCTIONAL ROOF DRAIN. SEE 20 1"CONDENSATE DROP TO FIXED AIR GAP FITTING. INSTALL FLOW ACTIVATED TRAP PRIMER DETAIL ON DWG. #P4.1 VALVE. SEE DETAIL ON DWG. #P4.1 O PIPE OVERFLOW RAIN LEADER (ORL) THROUGH EXTERIOR WALL APPROXIMATELY 18" ABOVE GRADE AND 21 PROVIDE THERMAL EXPANSION LOOP EQUAL TO METRAFLEX "METEA LOOP". PROVIDE ANCHORS TERMINATE WITH OVERFLOW DOWNSPOUT NOZZLE (ODN) WITH BIRD SCREEN. COORDINATE WITH AND GUIDES PER MANUFACTURER'S RECOMMENDATION (TYPICAL) ARCHITECTURAL ELEVATIONS. 22 3/4"CONDENSATE DROP TO FCU. CONNECT CONDENSATE TO FCU INTEGRAL CONDENSATE PUMP. 70 2"CW DROP TO WATER CLOSETS AND URINALS. PROVIDE WATER HAMMER ARRESTORS (WHA). COORDINATE POINT OF CONNECTION IN THE FIELD WITH HVAC CONTRACTOR AND ADJUST AS 80 4"S DN., 2"V UP, 1 1/4"CW & 1/2"HW DROP TO WATER CLOSET AND LAVATORY. PROVIDE WATER HAMMER REQUIRED. ARRESTOR (WHA) 23 1"CONDENSATE DROP IN WALL TO JANITOR SINK. TERMINATE 6" ABOVE SINK RIM. 1 1/2"W DN., 1 1 /2"V, 1/2"H&CW DROP IN WALL TO LAVATORIES PROVIDE INDIVIDUAL ISOLATION STOPS 24 HOT WATER MAINTENANCE CONTROLLER. COORDINATE POWER WITH ELECTRICAL CONTRACTOR SUPPLIES FOR EACH FAUCET. IN THE FIELD. SEE GENERAL DETAIL ON DWG. #P4.1 10 1 1/2"W DN., 1 1/2"V, 1/2"H&CW DROP IN WALL TO SINK. 25 1 1/2"W, 1 1 /2"V, 1/2"H&CW DROP IN WALL TO LAVATORIES PROVIDE INDIVIDUAL ISOLATION STOPS SUPPLIES FOR EACH FAUCET. PIPE WASTE LINES TO SOLID INTERCEPTOR. 11 2"W DN., 2"V UP, 1/2"H&CW DROP IN WALL TO ART ROOM SINK. SINK SHALL BE INSTALLED WITH SOLID INTERCEPTOR. SEE DETAIL ON DWG. #P4.2 26 FLOW ACTIVATED TRAP PRIMER VALVE FOR CONDENSATE DRAIN FIXED AIR GAP FITTING. INSTALL ON 1/2"CW LINE TO PLUMBING FIXTURE. SEE TRAP PRIMER DETAIL ON DWG. #P4.1 12 1 1/2"W DN., 1 1 /2"V, 1/2"H&CW DROP IN WALL TO SINK WITH BUBBLER. PROVIDE SEPARATE P-TRAPS FOR EACH BOWL AND SUPPLIES WITH STOPS FOR FAUCET AND BUBBLER. 27 ALL PIPING CROSSING SEISMIC JOINTS SHALL ACCOMMODATE DIFFERENTIAL MOTION. REFER TO -1 _ SPECIFICATION FOR ADDITIONAL INFORMATION. SEE ARCHITECTURAL AND STRUCTURAL U I I/Z VV UIN., I IZ V, uZ k VV DROP I O ELECTRIC WATER COOLER VVI T H BOT LE FILLER. DRAWINGS FOR LOCATIONS. 14 1/2"CW DROP IN WALL TO HOSE BIBB (HB) 28 1"CONDENSATE DROP TO UTILITY SINK. TERMINATE 6" ABOVE SINK RIM. 15 3/4"CW DROP TO EXTERIOR WALL HYDRANT ON WARM SIDE OF BUILDING INSULATION. 29 PROVIDE HOT WATER TEMPERATURE MAINTENANCE CABLE. INSTALL ON DOMESTIC HOT WATER SUPPLY BRANCH TO PUBLIC LAVATORIES WITHIN 2 FEET OF FIXTURE CONNECTION. A B © D E F © OH J� K L M N P Q ® T 1-1/2" STUDOR MINI -VENT AIR ADMITTANCE VALVE. ! INSTALLED IN WALL ON TOP OF WASTE RISER. ! i PROVIDE ACCESS DOOR IN WALL. ! II O - - ODN WH 15 - — - -- -- — '15 +— — — I — — _ _ I — — — — — — — — _ — — — — — — - o. nn� 12 I 1 2" H&CW TIGHT I I I I I I 11 0 STRUCTURE -- I I 12 , — _ of III L _j -__ 2"V, UP L 7—— — — — — ! — ----- -- �® JE ! I / 1 VESTIBU 20,, , I I IL III I I I -- I FC3-4 UL- - - - NSTRUMENTAL MUSIC O 22 I II I I I I I I I I AND P TFORM I 18 6 RL DN. ! - - - I I I - - - 6"RL&ORL - I I ! I r UP TO CORRIDOR - - --- - HWRP2 H 5"G. RISE WRP1 1 ! GAS SERVICE DN. --- - - - -- -: O - 2„V. DN. - - - - - _ 1 � - - � - � - � - _ _ _ _ i wI.r P1I0 I I I I GAS SERVICE REGULATOR AND GAS GutiH2 Cs'yVH'I 4 rLiz II I I I H � vv Ml METER BY GAS CO - - ---- - -- -- _ ___ - - -- - - - -14" 1 L 1— BUILDING GAS PRESSURE REGULATOR 4"G - - - - -- -' - - - - - — — — CLOSET _ 2' ® l) � � � ! � CTICE ROOM BY THE PLUMBING CONTRACTOR. - + ®-� _ " -®_ 15 _ 16 23 - -- - !--- 1s - - - - (3157 MBH) SET REGULATOR -AT 10"W.C. =� :_ ,b 1. +O I r- r I r I (1 115 ' KITCHEN GAS PRESSURE REGULATOR O O MEC 1A4NICAL 3 G j o ( B_1 FD2 C BY THE PLUMBING CONTRACTOR. „ I 2 ! 19 IAIR STORAGE I EWC \ PLATFORM ACCESS 26 0 (245 MBH) SET REGULATOR AT 7"W.C. - - 3 3 L I 3/4 CW 2'V. DN. J1 cam, - - - - - - - - _ 1s 6 f ® 17G I I FC3-8 13 � _ _ _ _ _ 2"V----o----=-1 I ` g-2 I 24 1 1/2'G. UP 1� I- 1 1/2,1/2 P 21/2"G. UP '--_--2"V- - _ P.E.OFFI E .VESTIBULE P.E. STORAGE C' �'FD2 1 HMC ® 22 --- -- — - — — " USTODI S 17 - — ® - - - - - - - - - - 2"V. DN. 4 GVTR - cV I - LADDER -TO FC3-7 1 U -t - - I 20 V 4 yT-R 2 ROOF HATCH, ---� ! > STORAGE FC3-5 3"CW 2"HW + I ! N \ _ CO N_ 18 1 "HWR RP7 I--- - -- - II --►- 4„G 4"G 4'G _ 411/l 4"G I 22 0 N 28 „ O I 4"DOMESTIC WATER SERVICE DN. 1 "HW (1400) o _ _ - - - -2"V' - - - 1 1/4 G. 22 O „ „ H 4 1/2'HWR (140) 1 1/4"G- FC5-1 - 3 CW, 2 HW, (D CORRIDOR U 3 CW 2 HW � � ' WATER METER, BYPASS ASSEMBLY, — - I - - - i ann utnrt Y I T�\ �� HWR -- - --- ---� HWR -- -_ - - -- — Y ..- --+rv,,vv��--�— - —( - 11 -- - 1%2"H&C-V-1� —I N --� iI . -- �"vD_ — -Y BACKFLOW PREVENTER AND F_ -140 nvvrc-- f _ _ _ _ 29 - PRESSSURE REDUCING VALVE FOR MAINELECT(iICAL - —► 4"G 3"G BUILDING DOMESTIC WATER 11 �= �' 2 '� 0 _ 2"CVO - -- -® ' 8 I I 'O 4"S. DN, EWC - �I FC3_12 1"H CORRIDOR COORDINATE INSTALLATION WITH I -' I /r �� � 5 (� 3"CW, 2"HW, WATER CO. SEE DETAIL ON DWG. #P3.1 - I i� I 1 s �� KITCb ry o�_AC I 2"V. � wsr TOILET ^ 13 ` � r�„uQ r 6"RL DN. ► I 8"ORL I�I 6'�RL---AIL-1° - 1/2"H&C O I 29 r 61R ��_ '►—_�—(} - ` Imo_±= � GIR TOILET �I B1 j 1/4" PER V-0" f ! -►--T 6"RL DN. / G -- Hg A II 4'VTR a.�n uW - ® 29 1 1/2"V. _ F 10 WEST LOBBY , - - ---- — — — — 186 3/4"C W I n 4"VTR ( 2" V VISUAL ARTS I CLASSROOM 119 I I I I I 3/4"v YA1 r " i 1/2" R. - -- FC3-1 -r 1 "C D-I _JY > O J i\I Q -- — 15 I �\ 16 I I I I� 11 1 I 17 - ,- - 5 3/4"CW 2� / 3/4"HW I _F -2 KILN ROOM C3 — 1 /2V SUALR RTS I ® I - r+ +1 33 21 -026 - -t -- � 25 1"HWR 1"Cp 1 27 - 4"VTR 22 1 1 /2"V -- - I GENERAL MUSIC 120 1 /2"C W, 1/2"HW 2 1/2"G. UP O' A ` - HR 14 -- -�- - -- - - r1 "eD - -- '� ��- � � � � _� -��I - I --� �� 6„RLDN.- RL I20' �'1' / ,I 9c'o — II _ _ _ 3/4 CW __ 14U HWR _ 3" FD3 GENERAL STORA,G 3/4 H&CW O 22 ® - -11/2 - - -l�j I O 3 7 O 12 '<, 1/2 CW- _� 1"H&CW FC3-9 co 16 ,3'pD1 C3 16 1 1/2"G. UP I. O I I }. 22 FC2-1' OUTDOOR EOUIPMEVT a „Li ff 1-1-A 1 1/4"G. FM ,' Al Al 2 1/2"G. UP w= -. p STORAGE 1 g W 22 1/2'V --� 2��V- - _2"V- -'- f I I U _-� FC2-13 F ID R �,,, _ _._ • • r 1/2 HWR �_-=- �— - � - - `. I I I 22 10 -<, ; I ,I 15- /� 5 4'LLDNI ! D((-� 6 ORL— J7EDIA CENTER OFFICE, ,- 6 VVH - I I 4"ORL I / I II ! 1"CD 1"CD � 1°4 L " 6 14"ORL DROP L _j 1 1/4 G. 1 ' 3/4 CW, - � 1 ! CAFETERIA I 1/2"HW CV - — —I �- — - D3--fi- —) — t I i > -3 i FD N 22 VESTIBULE J 1 STEM LAB I I p 1"CD DROP 7 I I R-OW I U_ O 1 FI F VIDEO PRODUCTION TO FLOOR I j eD I 14a / DRAIN !\ I I I I I 4"VTR I _ a - 12 V L---- - I - Ur o', p r I 1 ® MEDIA CENTER U 22 t I WORKROOM 04 D o I I I I I I I 1"C FC3-11 �22 FC3-10 FOOD MANAGER'S ! 10 6"ORL OFFICE -- 3/4"CW I FC2-12 CUSTODIAL OFFICE 09 , KI 1 99EN I I DROP P DROP - - - I I i 110 I� I I I I DP - _ _.... - - ODN O 6"(' " RL DROP I \ ODN WH 15 -- _ O ODINI ;6 1 P2.1Li Lj 1 PLUMBING FIRST FLOOR - WEST P1.2 1 /O" = 1'-0" MEDIA CENTER 104 'I CORRIDOR ' 182 J I I I I I i II I KEYPLAN I REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 1132-0089 N PHASE 2 OF 5 IPSLFC27A, PWCAL 21 pizu &1T_CC117ROCAf_ h5/ML17!%G\IL= 11 gly uw suorE 202 ROCKY 6f/LL, -T O6067 Pr (860) 436-4336 F. (860) 4364450 www.rzdes,rgnassociates.com V. C ",X' % cg ^\ NO.2N�/: 2 MOSE111"Z.- PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PLUMBING FIRST FLOOR PLAN - WEST DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. P1*2 0 0 N , a) E z U 0 PLUMBING DRAWING KEY NOTES 1O 2"CW DROP TO WATER CLOSETS AND URINALS. PROVIDE WATER HAMMER ARRESTORS (WHA). 20 1 1/2"W DN., 1 1 /2"V, 1/2"H&CW DROP IN WALL TO LAVATORY SYSTEM, PROVIDE INDIVIDUAL ISOLA i ION STOPS SUPPLIES FOR EACH FAUCET. O3 4"S DN., 2"V UP, 1 1/2"CW & 1/2"HW DROP TO WATER CLOSETS AND LAVATORIES. PROVIDE WATER HAMMER ARRESTOR (WHA) 4O 1 1/2"W DN., 1 1 /2"V, 1/2"H&CW DROP IN WALL TO SINK WITH BUBBLER. PROVIDE SEPARATE P-TRAPS FOR EACH BOWL AND SUPPLIES WITH STOPS FOR FAUCET AND BUBBLER. O 1 1/2"W DN., 1 1 /2"V, 1/2"CW DROP TO ELECTRIC WATER COOLER WITH BOTTLE FILLER. 6O 3"W DN., 1 1/2"V, 1/2"H&CW DROP TO JANITOR SINK. O 1/2"CW DROP TO HOSE BIBB (HB) O FLOW ACTIVATED TRAP PRIMER VALVE FOR FLOOR DRAIN. INSTALL ON 1/211CW LINE TO PLUMBING FIXTURE. EXTEND PRIMING LINE BELOW FLOOR TO FLOOR DRAIN. SEE TRAP PRIMER DETAIL ON DWG. #P4.1 O9 3/4"CONDENSATE DROP TO FCU. CONNECT CONDENSATE TO FCU INTEGRAL CONDENSATE PUMP. COORDINATE POINT OF CONNECTION IN THE FIELD WITH HVAC CONTRACTOR AND ADJUST AS REQUIRED. 10 CONNECT RAIN LEADER (RL) AND OVERFLOW RAIN LEADER (ORL). TO BI-FUNCTIONAL ROOF DRAIN. 11 1 "CONDENSATE DROP IN WALL TO JANITOR SINK. TERMINATE 6" ABOVE SINK RIM. 12 HOT WATER MAINTENANCE CONTROLLER. COORDINATE POWER WITH ELECTRICAL CONTRACTOR IN THE FIELD. SEE GENERAL DETAIL ON DWG. #P4.1 13 PROVIDE HOT WATER TEMPERATURE MAINTENANCE CABLE. INSTALL ON DOMESTIC HOT WATER SUPPLY BRANCH TO PUBLIC LAVATORIES WITHIN 2 FEET OF FIXTURE CONNECTION. 14 BI-FUNCTIONAL ROOF DRAIN WITH PRIMARY AND SECONDARY OUTLETS. �U V X ` 4 Z BB DD FF HH H. KK Iif PP QQ RR TT UU I I I I I I I I I I i I 71 I I ! I i I — - — — C13 7_74" ORRIDOR L1--j 282 I 1"H&CW inu 1 "CD DN. I I I 1(rcj o i I I I IJ I I SOUTH STAIRI o E GRADES 3.5 ® — CLASSROOM — — 15 _12171 — — -- — — — — — — 4t �f i j 16 ! ❑ N FC4 1 I r I IIOFI I ELEV. 12051 2 G. DN. I ovE Zi 1 H&CW --► 17 „ 1 1/2"V. DN I - - h 1 1/2"CW, C111 ,To ET '1/2"HW . y - ILET 203 - \ I I FC4-10B C 2 v w wrn"n+nr _ I i i u i I�G IiVV INSTRUCTIONAL 3 ,. -- „ 13 1„HW Ns AL 2"W. DN, 20 -- - - - — — - — — — — - — STORAGE_ — 47 Al Al ' 4„VTR z1 1 1 /2"V. -- i 4"S. DN, HMC 12 4' RL. DN.. 7 2 8 2 E5 i 2'V. a 11 11/2"H&CW - 10 ' I I 4"ORL f-LAI I- - - I- - -1 1/2"V. DN IJ _ HB RL & 4 ORL _ GENERALSTORAGE _ n. 202 r I UP TO RD. BOY S''TOIL T I 1 „C I� EWC 5 N z19 13 137 d I _ _ 2„CW, — 23 - - 1 1/2"V. ® 1 1/4"HW \ - 9 - - - I - 1/2"H&CW - i ., - - -O 4 VTR — DN.— Al - 24 t+v.' -2„V, -2„ 1 1/2"W. DN. 1 1 1/2"V. UP 7 n 4"ORL DN.I I 26 FC4-11 9 G. BREAK-OUT AREA 1 n , 4 A A A I Al I i 4 S.N, 2 SPECIAL EDUCATION RESipURCE ROOM 2� CW % 3'•FL� (j 2"CW I I I I 00 2 1 I I 1 1/2"HW DN. 8 C2 ®I 11 1/4"HW I � C GIRLS* 2 OIillLET HIB 13 . 9 \ — — Q -EAST LOBBY 0 Q lf� it Ld H_ L ! 3 I , - - — — I— — I i I i I I ! I -- I I I I I I I I I I i t I I I I. 11-.-i — — —I 46 I I , I ! NOTE: REFER TO PLUMBING ROOF PLAN ON DRAWING #P1.4 FOR SCOPE OF WORK 2 PLUMBING SECOND FLOOR - SOUTH P1.3 1/81I = 11-011 CORRIDOR 282 I I I li I I 1 PLUMBING SECOND FLOOR - NORTH P1.3 1/8t1 = 11-011 (D PROJECI NORTH KEYPLAN O REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 NEC11AN/CAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 F. (860) 4364450 www.rrdesignassociates. com a °A,�' ,PVD 'a + NO.252 r %F M0SER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PLUMBING SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. P1*3 a - I r Z AA BB DD FF HH H. KK � PP Q RR TT UU I i I I I I r I I I i I I I II I I I I I I I I I I I I I I I I I I I I I I I I I 2 PLUMBING ROOF PLAN - ALTERNATE 1 P1.5 1 /8" = 1'-0" PLUMBING DRAWING KEY NOTES O1 1 1/2"W DN., 1 1 /2"V, 1/2"H&CW DROP IN WALL TO SINK WITH BUBBLER. PROVIDE SEPARATE P-TRAPS FOR EACH BOWL AND SUPPLIES WITH STOPS FOR FAUCET AND BUBBLER. O2 CONNECT RAIN LEADER (RL) AND OVERFLOW RAIN LEADER (ORL) TO BI-FUNCTIONAL ROOF DRAIN. SEE DETAIL ON DWG. #P4.1 O BI-FUNCTIONAL ROOF DRAIN WITH PRIMARY AND SECONDARY OUTLETS. V 3/4"CONDENSATE DROP TO FCU. CONNECT CONDENSATE TO FCU INTEGRAL CONDENSATE PUMP. COORDINATE POINT OF CONNECTION IN THE FIELD WITH HVAC CONTRACTOR AND ADJUST AS REQUIRED. U CONNECT 2'V TO' BASE BUILDING 2"V 4"RL DN. CONNECT 3/4"HWR TO CAPPED 31"IWR IN ISE BUILDING �%%/�///////%%�/ a, y� Qoom ; y ,.v 0 i:� • ••� 1/81 1 = 1'-0" PLUMBING FIRST FLOOR - ALTERNATE 1 1 /8" = 1'-0" i,s Z, i I I I I I I II13 — U n REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pe (860) 436-4336 F. (860) 436-4450 www•rzdesignassociates.com r NO.2 � /cENSE MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ALTERNATE 1 - ADDED CLASSROOMS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. P1*5 2 0 0 N r a� E D z U a) O a z 0- REVISIONS EXTERIOR WALL. REFER - --' CONFORMED SET TO ARCHITECTURAL CAST IRON DOME CAST IRON OVERFLOW STRAINER DRAWINGS FOR MARCH 22, 201E CONSTRUCTION DETAILS. - --- ---- SUMP RECIEVER - COMBINATION FLASHING RING AND GRAVEL STOP OVERFLOW DOWNSPOUT NOZZLE. COORDINATE LOCATION AND - ELEVATIONS IN THE FIELD. REDUCED PRESSURE ZONE MAINTAIN 12" (MIN.) CLEAR SEE PLANS FOR SIZE - NO -HUB -HUB HEAVY DUTY ASSEMBLY BACKFLOW FOR SPACE ABOVE RPZ ASSEMBLY UNDERDECK STAINLESS STEEL COUPLING DOMESTIC WATER SERVICE MAINTAIN 12" (MIN.) CLEAR- - SPACE ABOVE RPZ CLAMP MAINTAIN 30" (MIN. ASSEMBLY RAIN WATER LEADER (RWL). CLEAR SPACE IN FRONT MAINTAIN 30" (MIN.) REFER TO PLANS FOR PIPE SIZE. QUARTER TURN BALL - ® ; a VALVE (TYP.) OF RPZ ASSEMBLY CLEAR SPACE IN FRONT REDUCED PRESSURE BALL VALVE MOUNTED ABOVE CEILING OR PROVIDE 2'x2' ACCESS DOOR. ZONE OF RPZ ASSEMBLY BRONZE THREADED CLEANOUT PLUG. BACKFLOW PREVENTER OVERFLOW RAIN LEADER MAINTAIN PROPER CLEARANCE PER CODE COORDINATE WITH ELECTRICAL CONTRACTOR FOR ROUGH IN. I i ASSEMBLY -TEST COCK (TYP.) � UNION (TYP.) -- . (ORL) DISCHARGE NOZZLE I` I tBALL VALVE (TYP.) INTERIOR ORL CHASE ENCLOSURE. REFER TO INLET OUTLET_ STRAINER ARCHITECTURAL DRAWINGS FOR CONSTRUCTION DETAILS. WATER MAIN oil- OVERFLOW RAIN LEADER AIR GAP FITTING PIPE - - - - ----i INLET ° OUTLET (ORL) SEE PLANS FOR SIZE. FURNISH AND INSTALL PPP #MPB-500 ELECTRONIC TRAP PRIMER (ETP) DEVICE. STATE PROJECT NO. 18" ABOVE FINISHED GRADE OR AS SHOWN ON NO -NUB HEAVY DUTY ° MAINTAIN 8" MIN. r` 132-0089 N ARCHITECTURAL DRAWINGS STAINLESS STEEL COUPLING ° �4 CLEAR SPACE OFF AaLJ OR ELEVATIONS. PPP INC. #DU DISTRIBUTION UNIT PIPE DISCHARGE TO DRAIN �' THE WALL TO RPZ PHASE 2 OF S GROUND FLOOR FOR MULTIPLE HUB DRAINS OR ° AIR GAP FITTING PIPE TO ---- - 4FLOOR DRAINS PRIMING. ° FLOOR DRAIN THROUGH AIR MAINTAIN 8" MIN. FINISHED GRADE LEVEL a 44 g o - FIN. FLOOR GAP Q CLEAR SPACE OFF THE WALL TO RPZ 1/2" TYPE "L" COPPER PRIMER s . ° LINE IN WALL OR ON THE FACE ° FIN. FLOOR---\ OF THE WALL FLOOR DRAIN OR ° . °. ° FRONT ELEVATION SIDE ELEVATION F.D. TO HUB DRAIN 4 a NOTES: Li FLOOR DRAIN OR HUB DRAIN FRONT ELEVATION SIDE ELEVATION 1. THE RPZ MOUNTING HEIGHT AND CLEARANCES INDICATED ABOVE NOTES: SHALL BE MAINTAINED FOR PROPER ACCESS TO UNIT FOR TESTING, NOTES: 1. COMBINATION BI-FUCTIONAL ROOF DRAIN. REFER TO ROOF PLANS FOR ROOF DRAIN SIZE AND MAINTENANCE, AND INSPECTION PURPOSES. 1. THE RPZ MOUNTING HEIGHT AND CLEARANCES INDICATED ABOVE STRUCTURAL AND ARCHITECTURAL DOCUMENTS FOR ROOF DECK CONSTRUCTION AND ROOF BUILD-UP , 4 SHALL BE MAINTAINED FOR PROPER ACCESS TO UNIT FOR TESTING, (INSULATION, FLASHING MEMBRANE VAPOR BARRIER, ETC.) PROVIDE EXTENSION RING AS REQUIRED FOR --- -__- ' 2. THE ASSEMBLY SHALL BE ADEQUATELY SUPPORTED AND/OR RESTRAINED PROPER INSTALLATION. TO PREVENT LATERAL MOVEMENT. PIPE HANGERS, BRACES, SADDLES, MAINTENANCE, AND INSPECTION PURPOSES. STANCHIONS, PIERS, ETC., SHALL BE USED TO SUPPORT THE DEVICE AND 2. THE ASSEMBLY SHALL_ BE ADEQUATELY SUPPORTED AND/OR RESTRAINED 2. INSULATE ROOF DRAIN SUMP BODY, RAIN WATER LEADER AND OVERFLOW RAIN WATER LEADER PER SHOULD BE PLACED IN A MANNER THAT WILL NOT OBSTRUCT ACCESS � TO THE TESTING PORTS OR VALVES. TO PREVENT LATERAL MOVEMENT. PIPE HANGERS, BRACES, SADDLES, SPECIFICATION. STANCHIONS, PIERS, ETC., SHALL BE USED TO SUPPORT THE DEVICE 3. REFER TO MANUFACTURED OF THE ROOF DRAIN FOR RECOMMENDED ROOF DECK OPENINGS BASED ON THE AUXILIARY FITTING WITH 1/2" N.P.T. CAST IRON DEEP AND SHOULD BE PLACED IN A MANNER THAT WILL NOT OBSTRUCT ACCESS SIZE OF THE DRAIN. INLET TAPPING FOR TRAP PRIMER SEAL "P" TRAP TO THE TESTING PORTS OR VALVES. CONNECTION I 1 COMBINATION BI-FUNCTIONAL ROOF DRAIN DETAIL 2 TYPICAL ELECTRONIC TRAP PRIMER DEVICE DETAIL 3 REDUCED PRESSURE ZONE BACKFLOW PREVENTER INSTALLATION DETAIL 4 TYPICAL BACKFLOW PREVENTER INSTALLATION DETAIL P4.1 NTS P4.1 NTS P4.1 NTS P4.1 NTS I L=4 r7 NOTE: DIMENSION "X" SHALL BE A MINIMUM OF 2", OR, 1/2" HIGHER THAN THE FAN SUCTION STATIC [� DRAIN PAN PRESSURE, WHICHEVER IS HIGHER 17 45° STREET FINISHED WALL OR ENCLOSURE. ` ELBOW (TYP) SLOPE @ 1/8 SOIL STACK OR RAIN REFER TO ARCHITECTURAL DWG'S. 0 PER FOOT, MINIMUM I WATER LEADER (RWL) —� • n. nDAini Dninrr I `' DRAIN LINE FROM 2"VENT EQUIPMENT CLEANOUT —'� ___ "MINIMUM 3"CW. TO BUILDING - � BRONZE THREADED NO -HUB HEAVY DUTY CLEANOUT PLUG WITH RAISED (TYP) PLUMBING FIXTURES BALL VALVE GENERAL NOTE: STAINLESS STEEL COUPLING OR COUNTERSUNK SQUARE (-FYP) ACCESS DOOR ON BATHROOM SIDE. HEAD WYE FITTING WALL CLEANOUT ACCESS COVER (-gyp) -- 3"CW. CAST IRON CLEANOUT TEE AT CUT END OF DRAT 99 THE BASE OF THE SOIL STACK OR RWL 10 SECURING ANCHOR LUGS PRESSURE REDUCING VALVE (PRV) AT 45° ANGLE 4"x2" SHORT REDUCER I FOR DRAW-THRU COILS PRESSURE GAUGE WITH a � VALVE 0-150 PSI (TYP) SET MAIN PRV VALVE AT 60 PSI AND 2­w— NO -HUB HEAVY DUTY LOWER PRV AT 70 PSI. SHORT CAST IRON- FINISHED FLOOR STAINLESS STEEL COUPLING --- - ------ -----.._.. ---- .......... - - - - -------------- --- PRV = 8"x4 REDUCER ° - -REDUCED PRESSURE ZONE (RPZ) BACKFLOW PREVENTER ASSEMBLY DRAIN PAN 1/2" MINIMUM WATER METER FURNISHED AND INSTALLED BY i' CAST IRON CLEANOUT TEE ---- -- — THE WATER CO. PROVIDE SPACER PER WATER RPZ DEEP SEAL CAST WITH BRONZE THREADED I CO. REQUIREMENTS. COORDINATE WITH METER BY-PASS PER IRON "P"TRAP 4- CLEANOUT PLUG. V LOCAL WATER CO. NC WATER CO. STANDARDS 45° STREET i 3" CW. ® WATER SERVICE MAIN FINISHED FLOOR-\ @ GATE VALVE (TYP.) 4"WASTE. TO BUILDING STORM ELBOW (TYP) - SLOPE 1/M DRAIN VALVE- M OR SANITARY DRAIN � PER FOOT, MINIMUM ® �----------- --- -- CAST IRON LONG TO DRAIN POINT :°.. SWEEP BEND CLEANOUT -- NOTE: FINISHED FLOOR - -- TYPE WHERE USE DIMENSION "X" SHALL BE A ` REQUIRED. (TYP)DIMENSION OF 2" OR 1/2" HIGHER THAN THE FAN DISCHARGE STATIC WYE FITTING PRESSURE, WHICHEVER IS HIGHER W (TYP) ---_-- -- BURIED 4"DOMESTIC��, NOTE: WATER SERVICE CAST IRON LONG SWEEP-D BUILDING WATER METER ASSEMBLY SHALL BE ADEQUATELY SUPPORTED BEND. USE REDUCING DRAINAGE SYSTEM G��hG�G9©(aJ� ]G�7® FOR BLOW-THRU COILS AND RESTRAIN TO PREVENT LATERAL MOVEMENT TYPE WHERE REQUIRED. ELECTRICAL E/VG/MEERING 5 COOLING COIL CONDENSATE TRAP DETAIL 6 WATER METER SCE ilE .TIC ET IL ��®®LDMA,AISTdiEET 7 TYPICAL HUB DRAIN DETAIL "P-TRAP" ABOVE FLOOR g TYPICAL CLEANOUT DETAIL AT BASE OF SOIL STACK OR RWL suiTez®2 P4.1 NTS P4.1 NOT TO SCALE KE9 NTS P4.1 NTS ROCKY HILL, CT06067 Pr (860) 4364336 F. (860) 436-4450 www.rzdesignasS0Ciate5.c0m END SEAL lzv: f - - HEATING CABLE 1/2 COLD WATER LINE --- PPP INC. #PR01-500, WATER TEE TO PLUMBING FIXTURE. FLOW ACTIVATED TRAP PRIMER. �:NO.25239 ` (MINMUM FLOW .5 GPM). O HOT BRANCH LINENS,. lop UNION COLD WATER MAIN , THERMAL INSULATION HOT WATER MAIN OR BRANCH LINE - 1/2"BALL VALVE r HMC, --- HORIZONTAL PRIMING CONTROLLER LINE MUST BE PITCHED TO BMS CONDENSATE DRAIN LINE MOSER FROM EQUIPMENT - -- -- - 2'x2' ACCESS DOOR IL" N SPLICE SETSCREW 2" VENT NE SCHEDULE 40, BLACK STEEL GAS PIPE LSON J.R.SMITH #3955S CAST -- PROVIDE ACCESS PANEL FOR /�- WITH WELDED JOINTS. A R C H I T E C T S IRON FIXED AIR GAP FITTING -=Q� 'AIR GAP FITTING" AND "P" NOTE: ALL NEW AND EXISTING GAS TRAP IF INSTALLED IN WALL OR 208 VOLT, 1-PHASE TO POWER 3 o J O R E L , LANE J.R.SMITH #7080 CAST IRON PIPING SHALL BE PAINTED WITH PRIMER w E T H e R s F i e L o, CT. 06109 IN CHASE DISTRIBUTION PANEL STAINLESS STEEL (860) 563-6164 INSTALL PROSET SYSTEM, INC. BALL FLOAT BACKWATER _ AND (2) COATS OF RUST INHIBITIVEDRAIN STRAINER #TG3H TRAP GUARD INSERT VALVE - --- --- - --- --- - -'—► I PIPE STRAP PAINT. ��- CAST IRON SAN TEE FITTING DEEP SEAL CAST IRON — FINISHED FLOOR "P' TRAP - - -- -! ® NO -HUB HEAVY DUTY STAINLESS POWER CONNECTION TITLE 1 - - NOTES: -- STAINLESS STEEL THREADED ROD STEEL COUPLING. TYP. � PLUMBING .6 °• 2" WASTE 1. FURNISH AND INSTALL PER MANUFACTURER'S INSTRUCTIONS, DOMESTIC HOT WATER TEMPERATURE MAINTENANCE SYSTEM AS DETAILS 1 �� CAST IRON CLEANOUT TEE FINISHED FLOOR WITH BRONZE THREADED MANUFACTURED BY RAYCHEM, USING HWAT-R2 (208V) SERIES CABLE FOR DESIGN TEMPERATURE OF 120F (ALTERNATE MANUFACTURERS f— POLYCARBONATE BASE CLEANOUT PLUG. MAY BE SUBMITTED FOR REVIEW AS POSSIBLE EQUALS) CABLE SHALL BE INSTALLED ON DOMESTIC HOT SUPPLY WATER LINES TO PUBLIC LAVATORIES WITHIN 2 FEET OF FIXTURE CONNECTION UNLESS OTHERWISE INDICATED ON DRAWINGS. PRODUCT SHALL BE TESTED PER ,_ __ --- - -- - -- - ----__ --- - _ MANUFACTURERS INSTRUCTIONS DURING INSTALLATION AND TESTING DOCUMENTED TO QUALIFY FINAL INSTALLATION FOR _ - -- FLOOR DRAIN. SEE DRAWIN MANUFACTURER'S 10 YEAR WARRANTY. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ROOF STRUCTURE, - SYSTEM SHALL INCLUDE ONE (1) HWAT-ECO CONTROLLER FOR EACH CIRCUIT AS REQUIRED. CABLE SHALL BE INSTALLED BY A LICENSED REFER TO ARCHITECTURAL FOR SIZE AND SCHEDULES DRAWINGS FOR TYPE AND POLYCARBONATE ROLLER FOR TYPE PLUMBING CONTRACTOR WITH FINAL ELECTRICAL CONNECTIONS PERFORMED BY THE ELECTRICAL SUBCONTRACTOR. SYSTEM MUST -- --- WASTE INCLUDE PIPE INSULATION INSTALLATION THAT FOLLOWS MANUFACTURER'S INSTRUCTIONS FOR CORRECT PERFORMANCE. ADDITIONAL INFORMATION. DATE 1 1/2/2018 1 MIRO #5-RAH-12 OR EQUAL. NON-PENETRTING ® TO BUILDING 2. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR ROOFTOP ADJUSTABLE HEIGHT PIPE STAND COPYRIGHT (c) DRAINAGE SYSTEM PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION. DO NOT SCALE THE DRAWING SUPPORT. SELF LUBRICATING POLYCARBONATE Moser Pilon Nelson Architects CAST IRON LONG SWEEP - ROLLER MOUNTED ON ALL STAINLESS STEEL CAST IRON DEEP BEND. USE REDUCING 3. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE THREADED ROD SUPPORT SYSTEM. INSTALL PER DWG. NO. SEAL "P" TRAP TYPE WHERE REQUIRED. PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE. MANUFACTURE RECOMMENDATION. 9 TYPICAL FLOOR DRAIN WITH TRAP GUARD INSERT DETAIL 10 FIXED AIR GAP CONDENSATE TO WASTE CONNECTION DETAIL ll HOT WATER TEMPERATURE MAINTENANCE DETAIL 1? GAS PIPE ROOF SUPPORT DETAIL AT HVAC CONNECTION p P4.1 NTS P4.1 NTS P4.1 NTS P4.1 NTS 1 • lg REVISIONS FUEL -FIRED WATER HEATER SCHEDULE GENERAL NOTE: REFER TO SPECIFICATION FOR MORE DETAIL DESCRIPTION OF THE EQUIPMENT AND EQUIPMENT EQUIVALENTS. PROVIDE SUPPORTS, FITTINGS, ADAPTERS, ETC. AS NECESSARY TO MAKE FINAL CONNECTION TO EQUIPMENT. TYPE EQUIPMENT DESCRIPTION REMARKS GWH-1 & 2 GAS WATER HTP "PHOENIX" MODEL PH-199-119, HIGH EFFICIENCY TANK TYPE, GAS -FIRED WATER 120V, 10, 60 HZ. HEATER HEATER, RATED FOR A MODULATION INPUT RANGE OF 40,000-199,000 BTU/HR., 237 GPH 5 AMPS RECOVERY AT 100'F TEMPERATURE RISE AND 119 GALLON STORAGE TANK CAPACITY. I HE HCA I ER TANK SHALL BE CONSTRUCTED OF 316L STAINLESS SIEEL THE PRInnARV CONDENSING HEAT EXCHANGER SHALL BE CONSTRUCTED OF 90/10 CUPRONICKEL. THE SECONDARY HEAT EXCHANGER SHALL BE CONSTRUCTED OF 800H STAINLESS STEEL AND 90/10 CUPRONICKEL. HEATER TANK BE 2" THICK WATER BLOWN FOAM, ENCLOSED IN A PLASTIC JACKET. THE HEATERS SHALL MEET THE MINIMUM EFFICIENCY REQUIREMENTS OF ASHRAE 90.1-2010. ALL HEATERS WILL BE SUPPLIED WITH A FACTORY INSTALLED ASME RATED TEMPERATURE AND PRESSURE RELIEF VALVE, A LOW WATER CUTOFF, A HIGH TEMPERATURE SWITCH, AN UPPER HOT WATER SENSOR, A LOWER COLD WATER SENSOR, AND A CONDENSATE TRAP ASSEMBLY READY FOR EASY CONNECTION TO A FIELD SIIPPL IFn CONDENSATE DRAIN. THE HEATER SHALL HAVE AN INTEGRATED DIGITAL CONTROLLER DEVICE WITH INTEGRAL DIAGNOSTICS, LED FAULT AND TEMPERATURE SETTINGS FOR ESTABLISHING SET POINT AND TEMPERATURE DIFFERENTIAL. IGNITION SHALL BE DIRECT SPARK AND TAKE PLACE AT A SPEED PRE-SET FOR THE BURNER BLOWER. THE CONTROL SHALL UTILIZE AN ALGORITHM TO FULLY ADJUST THE BURNER MODULATING FIRING RATE WHILE MAINTAINING THE DESIRED TEMPERATURE. THE DIGITAL LED CONTROL DISPLAY SHALL PROVIDE MEANS, VIA PUSH BUTTONS, FOR ADJUSTMENTS OF OPERATING TEMPERATURES, DIFFERENTIAL ADJUSTMENT, ECO RESET, SERVICE MODE, AND REAL TIME STATUS MODE. THE HEATER SHALL BE IN COMPLIANCE WITH THE NOX EMISSIONS LIMIT SET FORTH IN SCAQMD RULE 1146.2. THE HEATER SHALL BE FACTORY ASSEMBLED, TEST -FIRED FOR CORRECT BTU INPUT, AND ADJUSTED FOR PROPER COMBUSTION PARAMETERS. COMPLETE OPERATING AND INSTALLATION INSTRUCTIONS SHALL BE FURNISHED WITH EVERY HEATER AS PACKAGED BY THE MANUFACTURER FOR SHIPPING. 120 VOLT. "ET" EXPANSION AMTROL "THERM-X-TROL" ST-30-C, 14 GALLON, 16" DIA X 19" HIGH, ASME PRECHARGED TANK THERMAL EXPANSION TANK, WITH A HEAVY DUTY BUTYL BLADDER SUITABLE FOR DOMESTIC POTABLE WATER SYSTEM, ALL INTERNAL WETTED PARTS MUST COMPLY WITH FDA REGULATIONS. THE TANK SHALL HAVE A SYSTEM CONNECTION AND CHARGING VALVE TO FACILITATE THE ON -SITE CHARGING OF THE TANK TO MEET SYSTEM REQUIREMENTS. THE TANK MUST BE CONSTRUCTED IN ACCORDANCE WITH SECTION Vill OF THE ASME BOILER AND PRESSURE VESSEL CODE. RATED FOR 150 PSI WORKING PRESSURE AND 210°F TEMPERATURE. WATER DISTRIBUTION PUMPS SCHEDULE TYPE EQUIPMENT DESCRIPTION REMARKS HWRP1 HOT WATER BELL & GOSSETT #PL-30B, BRONZE BODY, HORIZONTAL LUBRICATED TYPE IN -LINE PUMP, RETURN PUMP SUITABLE FOR POTABLE WATER SERVICE, 225F OPERATION AT 150 PSIG WORKING (BUILDING) PRESSURE AND SHALL BE UL LISTED. MOTOR SHALL HAVE BUILT-IN OVERLOAD PROTECTION. PUMP SHALL HAVE CAPACITY OF 10 GPM AT 18 FEET OF HEAD. RATED FOR 1/12 HP, 120V-1. INCLUDE #TC-1 AUTOMATIC TIMER KIT AND #AQS AQUASTAT. HWRP2 HOT WATER BELL & GOSSET T #NBF-22, BRONZE BODY, HORIZONTAL LUBRICATED TYPE IN -LINE PUMP, RETURN PUMP SUITABLE FOR POTABLE WATER SERVICE, 225F OPERATION AT 150 PSIG WORKING K i�i.a (KITCHEN) IEN) MOr-001 IBC AIK1n CUAI 1 DC 1 II 1 IQTGn nnnTr)P QWAI I 1-IAVF RI III T-INI n\JEI?LnAn r1\LVVv1\L fnim" VI if, uL vL ",v 1 L✓. IVIV 1 01, VI IAu..- 1 u,vE ✓UL PROTECTION. PUMP SHALL HAVE CAPACITY OF 8 GPM AT 10 FEET OF HEAD. RATED FOR .80 AMPS,120V-1. INCLUDE #TC-1 AUTOMATIC TIMER KIT AND #AQS AQUASTAT. EMERGENCY FIXTURE SCHEDULES TYPE FIXTURE SOIL VENT COLD HOT MOUNT DESCRIPTION REMARKS EF IEMERGENCY -- -- 314" TEPID HAWS #7610, BARRIER -FREE SINK MOUNT EYE/FACE EYE'FArM 1AIAQU L 1 //-lVL VY/-1V1 1 \A/ACH IAIITI4 FVF/FA(F 1n/ASH HFAn WITHIN\/FRTFn UNIT DIRECTIONAL LAMINAR FLOW SUPPLIED BY AN INTEGRAL 4.2 GPM FLOW CONTROL.. ALSO INCLUDED; POLISHED CHROME BRASS SINGLE ACTION PULL - DOWN VALVE BODY. ETMV EMERGENCY __ __ 1/2" 1/2" HAWS #9201EFE, THERMOSTATIC MIXING VALVE WITH THERMOSTATIC POSITIVE SHUT OFF OF HOT WATER AND BUILT-IN MIXING VALVE COLD WATER BY-PASS, ASSURING COLD WATER (EYE/FACE WASH FLOW. UNIT SHALL INCLUDE CHECK STOPS & UNIT) THERMOMETER. SET AT 85 F. PLUM BIM(G-3 WATER SPECIALTIES SCHEDULE GENERAL NOTE: PROVIDE SUPPORTS, FITTINGS, ADAPTERS, ETC. AS NECESSARY TO MAKE FINAL CONNECTION. REFER TO SPECIFICATION FOR MISCELLANEOUS WATER SPECIALTIES AND FOR WATER SPECIALTIES EQUIVALENTS. ITEM SPECIALTY ITEM DESCRIPTION REMARKS "WHA" WATER HAMMER SIOUX CHIEF "HYDRA -RESTER" SEAMLESS PRESSURE CHAMBER. SPUN CLOSED COPPER PROVIDE AT QUICK ARRESTORS TUBE PERMANENTLY SEALS A 60 PSIG. SHALL CONFORM TO ASME/ANSI STANDARDS AND PDI CLOSING VALVES CERTIFIED. INSTALL PER FACTORY RECOMMENDATION. LIFETIME WARRANTY "RPZ" BACKFLOW WATTS #LF909-QT-S, REDUCED PRESSURE BACKFLOW PREVENTER, ALL BRONZE BODY PIPE RELIEF I U FLUOR PREVENTER CONSTRUCTION WITH STRAINER & QUARTER TURN BALL VALVES. #909AG FIXED AIR GAP. DRAIN OR AS INDICATED ON DWG'S. "PRV" PRESSURE WATTS #LFM115-74, 3" PILOT OPERATED TYPE PRESSURE REDUCING VALVE W/ FLANGED END PIPE RELIEF TO FLOOR REDUCING VALVE CONNECTION. PROVIDE 3" FULL PORT BALL VALVES. DRAIN OR AS INDICATED ON DWG'S. "FIB" HOSE BIBB WOODFORD #B26P, CHROME FINISHED CONSTRUCTION WALL FAUCET WITH VACUUM BREAKER - BACKFLOW PREVENTER IN WALL BOX, 3/4"HOSE CONNECTION AND WHEEL HANDLE "Inn M vvn 1A1A1 f UVnMANIT V Vh1LL rl I LJIIYKIV 1 1A100DFnRn 1#11 0DE-1 C.S2 DnI ICUGn MPAQQ GRP1=7I=1 FCC \A/AI I NVnRANT \A/ITH INTF(;RAI V VlJv"i -, tTlvld./tJLL vv, 1 v1...1v1 1.v vl 1_ 1 1 KI_r_-�.I. --- v v1 .��. . , �...., . , . ,., , , .....-...... .� "TEE" SEE ARCHITECTURAL PLANS FOR WALL (RECESSED) VACUUM BREAKER (ASSE 1052), STAINLESS STEEL COVER, 3/4"HOSE CONNECTION HANDLE KEY. THICKNESS "TMV" HI -LOW ACORN #MV17-3, HI- LOW THERMOSTATIC MIXING VALVE. THERMOSTATIC LEAD FREE BRASS BODY, CHECK STOPS, THERMOMETERS, BRASS FITTING & UNIONS, MIXING VALVE PRESSURE GAUGES, BALL VALVES, WALL BRACKET AND SPARE "RC" CARTRIDGE FOR EACH CONTROLLER. ASSEMBLY SHALL BE FACTORY ASSEMBLED AND TESTED. "ETP" ELECTRONIC TRAP PPP #MPB-500, MINI -PRIME ELECTRONIC TRAP PRIMING DEVICE HOUSED IN NEMA METAL BOX 120 VOLT PRIMER DEVICE WITH COVER. UNIT SHALL EMPLOY SOLENOID VALVE, AIR GAP AND ELECTRONIC CONTROLLER. PROVIDE DISTRIBUTION UNITS #DU-2, 3 OR 4 FOR MULTIPLE DRAIN PRIMING. NUMBER OF "DU" TO BE DETERMINED BY THE CONTRACTOR PER MANUFACTURER RECOMMENDATION. PLUMBING FIXTURE SCHEDULE GENERAL NOTES: PIPE SIZES SHOWN ARE FOR SUPPLY AND DRAINAGE ONLY. PROVIDE SUPPLIES WITH 1/4 TURN BALL STOPS, SEMI -CAST "P" TRAPS, PLUMBING FIXTURE SUPPORTS AND NECESSARY FITTINGS TO MAKE FINAL CONNECTION. REFER TO SPECIFICATION FOR EQUIVALENTS AND ARCHITECTURAL DOCUMENTS FOR EXACT PLUMBING FIXTURE MOUNTING HEIGHTS. TYPE FIXTURE SOIL VENT COLD HOT MOUNT DESCRIPTION REMARKS J JANITOR SINK 3" 1 1/2" 1/2" 1/2" FLOOR FIAT "MOLDED -STONE" #MSB-2424, 24"x24"x10"DEEP MOP SERVICE BASIN WITH THE FOLLOWING OPTIONS: #E-77AA-36 BUMPER GUARDS, #889CC MOP HANGER, #832AA HOSE & BRACKET #830AA WALL FAUCET WITH VACUUM BREAKER, #MSG3624 WALL GUARD A JANITOR SINK 3" 1 1/2" 1/2" 1/2" FLOOR FIAT "MOLDED -STONE" #MSB-2424, LOCATED IN CUSTODIAL 24"x24"x10"DEEP MOP SERVICE BASIN WITH THE STORAGE #116 FOLLOWING OPTIONS: #E-77AA-36 BUMPER GUARDS, #889CC MOP HANGER, PROVIDE AND INSTALL #832AA HOSE & BRACKET, #MSG3624 WALL CHICAGO FAUCET #952 AND GUARD RPZ ADAJCENT TO MOP SINK IF CHEMICAL DISPENSING SPEAKMAN #SEF-9000-FM-TMV UNIT IS REQUIRE SERVICE SINK FAUCET/EYESAVER COMBINATION, EYEWASH FAUCET WITH EYEWASH THERMOSTATIC MIXING VALVE IS A ROUGH CHROME PLATED SERVICE SINK FAUCET AND EYEWASH WITH TWIN SPRAY OUTLETS WITH FLIP - TOP DUST COVERS. K SINGLE BOWL 1 1/2" 1 1/2" 1/2" 1/2" WALL ELKAY, #WCLWO1923OSD, 18 GAUGE, TYPE 304 INSTALL WITH EF AND ETMV SINK WITH STAINLESS STEEL SINK, SELF RIMMING, (2) EMERGENCY FAUCET HOLES, 19"x 23"x 4" DEEP BOWL, EYEWASH UNIT #LKAD174 DRAIN, #LKF298 OVERFLOW ASSEMBLY, (NURSE SINK) CHICAGO #116.975.AB.1, QINK-11 F HOLE F-1/4" PI n1N CONTROL RIGID / VIIVVI...t- SWING GOOSENECK SPOUT, SELF SUSTAINING POWER SYSTEM, STAINLESS STEEL HOSES, THERMOSTATIC MIXING VALVE, ASSE 1070 1.5 GPM LAMINAR FLOW CONTROL ELECTRIC WATER COOLER SCHEDULE GENERAL NOTES: PIPE SIZES SHOWN ARE FOR SUPPLY AND DRAINAGE ONLY. PROVIDE SUPPLIES WITH STOPS, SEMI -CAST "P" TRAPS, PLUMBING FIXTURE SUPPORTS AND NECESSARY FI 1 1 INGS TO MAKE FINAL CONNECT ION. REFER Tn SPEC IFIC;A 1 i0 v FOR Lwu vALEf V1TS. TYPE FIXTURE SOIL VENT COLD HOT MOUNT DESCRIPTION REMARKS "EWC" WATER COOLER 1 1/2" 1 1/2" 1/2" --- WALL PER ELKAY #LZWS-LRPBM28K, TWO -LEVEL WATER REFER TO POWER ANSI/ADA COOLER WITH BOTTLE FILLING STATION. UNITS SHALL PLANS FOR CIRCUITING STANDARD HAVE FRONT PUSH BUTTON ACTIVATION, BOTTLE ARRANGEMENTS FILLING ELECTRONIC SENSOR, STAINLESS STEEL BASIN WITH INTEGRAL DRAIN, "FLEXI-GUARD" SAFETY BUBBLER, WATER SENTRY FILTER CERTIFIED TO NSF LKAPR1 -CANE APRON 42 AND 53 STANDARD, AUTOMATIC FILTER STATUS, WHERE ADA REQUIRED ANTI -MICROBIAL PROTECTION, UNITS SHALL HAVE A 5 YEAR WARRANT Y. UNIT SHALL MEET ADA GUIDELINES. UNIT RATED FOR 8.0 GPH OF 50'F DRINKING WATER. ELECTRICAL REQUIREMENTS: 10 AMPS, 120V/60HZ/10, PLUMBING DRAINAGE SPECIALTIES SCHEDULE GENERAL NOTE: PROVIDE SUPPORTS, TRAPS, ADAPTERS, ETC. AND NECESSARY FITTINGS TO MAKE FINAL CONNECTION. REFER TO SPECIFICATION FOR MISCELLANEOUS DRAINAGE SPECIALTIES AND FOR DRAINAGE SPECIALTIES ITEMS EQUIVALENTS. ITEM SPECIALTY ITEM DESCRIPTION REMARKS/ ELECTRICAL WALL CLEANOUT ACCESS J.R. SMITH #4720-U, FACE OF -WALL CHROME -PLATED BRONZE ROUND FRAME AND COVER (ROUND) SECURED COVER. VANDAL PROOF SCREWS. FCO FLOOR CLEANOUT J.R. SMITH #4032L-U, CAST IRON CLEANOUT, WITH ROUND ADJUSTABLE NICKEL -BRONZE PROVIDE "Y" CARPET (ROUND) TOP, GASKET SEAL AND BRONZE PLUG, VANDAL PROOF TOP. MARKER FOR CARPET FINISHED FLOORS "RD1" ROOF DRAIN FROET #100C-DC-DP-OFS-DEX. BI-FUNCTIONAL CAST IRON ROOF DRAIN WITH SIDE REFER TO ROOF PLANS PRIMARY OUTLET DRAIN CONNECTION AND BOTTOM OUTLET OVERFLOW CONNECTION FOR SIZE. WITH STANDPIPE AND CAST IRON OVERFLOW STRAINER, COMBINED FLASHING RING AND GRAVEL STOP, CAST IRON DOME, DECK CLAMP, DRAIN PAN AND RING EXTENSION. /1/lt.l 1 I 1v 1T T/ nr- i- -rr-fnf%/IIA ICiI ov -TUC !`nIKITE)ArTn0 EX I ENSIVIV I-ICIUri 1 1 V DC vG 1 CRIv1uVCv 01 1 nG I Ivv 1 vl\. "ODN" OVERFLOW DRAIN FROET #LPS, HIGH CORROSION RESISTANT ALUMINUM ALLOY NOZZLE WITH FLAPPER NOTE: COLOR NOZZLE BIRD SCREEN. SECURE AND ANCHOR TO EXTERIOR WALL. PROVIDE VANDAL RESISTANT SELECTION BY THE MOUNTING SCREWS AND NO -HUB CONNECTOR SCREEN. NOZZLE SIZE SAME AS ARCHITECT. OVERFLOW RAINWATER LEADER INDICATED ON FLOOR PLANS. "FD1" FLOOR DRAIN J.R. SMITH #2005Y-,A-,-U, CAST IRON BODY WITH FLASHING COLLAR, 6"DIA. ROUND PROVIDE FUNNEL FOR NICKEL -BRONZE ADJUSTABLE STRAINER. VANDAL PROOF SCREWS.INSTALL WITH DEEP ICE MAKERS AND SEAL "P" TRAP AND TRAP SEAL GUARD CONDENSATE "FD2" FLOOR DRAIN J.R. SMITH #2131Y-U-P, CAST IRON DEEP BODY, AND FLASHING COLLAR 12" DIA. CAST LOCATED IN IRON BAR GRATE. VANDAL PROOF SCREWS, TRAP PRIMER CONNECTION. INSTALL WITH MECH. ROOMS. DEEP SEAL "P" TRAP �nz11 CI nnQ nI�Alni J.R. SMITH #2131Y-U-P-M. CAST IRON DEEP BODY, AND FLASHING COLLAR 12" DIA. LOCATED IN OUTDOOR LV V1 K V1 \l111tl DUCTILE IRON GRATE. VANDAL PROOF SCREWS, TRAP PRIMER CONNECTION. INSTALL STORAGE ROOM WITH DEEP SEAL "P" TRAP. "FD4" FLOOR DRAIN J.R. SMITH #2005Y-A-H-B-U, CAST IRON BODY WITH FLASHING COLLAR, 6"DIA. ROUND LOCATED IN NICKEL -BRONZE ADJUSTABLE STRAINER, HINGED GRATE, SEDIMENT BUCKET, VANDAL CUSTODIAL ROOMS PROOF SCREWS, INSTALL WITH DEEP SEAL "P" TRAP AND TRAP SEAL GUARD "FS1" FLOOR SINK J.R. SMITH #9693Y-13, 12" SQUARE TOP, 8"DEEP, 14 GAGE TYPE 304 SS RECEPTOR BODY LOCATED IN KITCHEN WITH SEEPAGE CONTROL HOLES, CAST TYPE 316 SS RIBBED NON -TILT LOOSE SET GRATE WITH 3/4"(13) SQUARE HOLES, PERFORATED SS DOME BOTTOM STRAINER. SIZE AS INDICATED ON FLOOR PLANS. "FS2" FLOOR SINK J.R. SMITH #9694Y-1 3,12" SQUARE TOP, 10"DEEP, 14 GAGE TYPE 304 SS RECEPTOR BODY LOCATED IN KITCHEN WITH SEEPAGE CONTROL HOLES, CAST TYPE 316 SS RIBBED NON -TILT LOOSE SET GRATE WITH 3/4"(13) SQUARE HOLES, PERFORATED SS DOME BOTTOM STRAINER. SIZE AS INDICATED ON FLOOR PLANS. "SI" SOLID INTERCEPTOR J.R. SMITH #8710-ARI, SOLIDS INTERCEPTOR TRAP. FABRICATED WHITE DUCO COATED CAST IRON BODY WITH ALUMINUM GASKETED COVER & SEDIMENT STRAINER WITH REMOVABLE STAINLESS SCREEN. PLUMBING FIXTURE SCHEDULE GENERAL NOTES: PIPE SIZES SHOWN ARE FOR SUPPLY AND DRAINAGE ONLY. PROVIDE SUPPLIES WITH 1/4 TURN BALL STOPS, SEMI -CAST "P" TRAPS, PLUMBING FIXTURE SUPPORTS AND NECESSARY FITTINGS TO MAKE FINAL CONNECTION. REFER TO SPECIFICATION FOR EQUIVALENTS AND ARCHITECTURAL DOCUMENTS FOR EXACT PLUMBING FIXTURE MOUNTING HEIGHTS. TYPE FIXTURE SOIL VENT COLD HOT MOUNT DESCRIPTION REMARKS A WATER CLOSET 4" 2" 1" --- WALL KOHLER "KINGSTON" #K-4325, VITREOUS CHINA, ELONGATED (BOWL, TOP SPUD, SIPHON JET ACTION 1.28 GPF. CHURCH #31 i5C, ELONGATED OPEN I-KUN I TOILET SEAT WITHOUT COVER, ANTI -BACTERIAL. SLOAN "OPTIMA" #G28111-1.28, BATTERY POWERED, INFRARED SENSOR FLUSH VALVE. Al WATER CLOSET 4" 2" 1" -- WALL KOHLER "KINGSTON" #K-4325, VITREOUS CHINA, MOUNT FLUSH VALVE ELONGATED (BOWL, TOP SPUD, SIPHON JET HANDLE, PER A.D.A. ACTION 1.28 GPF. /ANSI STANDARD CHURCH #3155C ELONGATED OPEN FRONT TOILET SEAT WITHOUT COVER, ANTI -BACTERIAL. SLOAN "OPTIMA" #G28111-1.28, BATTERY PCM/PRFn I(\IFRARFD SENSOR FLUSH VALVE, A2 WATER CLOSET 4" 2" 1" ___ FLOOR KOHLER "JUVENILE ULTRA" #K-96059, FLOOR LOCATED IN KINDGARTEN MOUNTED, VITREOUS CHINA, ELONGATED BOWL, 1-1/2" TOP SPUD SIPHON JET FLUSH ACTION TYPE, 1.28 GPF. CHURCH #3155C, ELONGATED OPEN FRONT TOILET SEAT WITHOUT COVER, ANTI -BACTERIAL. SLOAN, OPTIfOA, #G28111-1.28, BATTERY POWERED, ELECTRONIC INFRARED SENSOR FLUSH VALVE, 1.28 GPF, 1-1/2" TOP SPUD, SCREWDRIVER STOP, VANDAL RESISTANT STOP CAP. A3 WATER CLOSET 4" 2" 1" ___ FLOOR KOHLER "WEILLCOMME ULTRA" #K-96053, FLOOR LOCATED 1ST AND 2ND ngnl InITFn VITREnUIS CHINA FLONGATED BOWL; GRADE 1-1/2" TOP SPUD SIPHON JET FLUSH ACTION TYPE, 1.28 GPF. CHURCH #3155C, ELONGATED OPEN FRONT TOILET SEAT WITHOUT COVER, ANTI -BACTERIAL. SLOAN, OPTII\AA, #G28111-1.28, BATTERY POWERED, ELECTRONIC INFRARED SENSOR FLUSH VALVE, 1.28 GPF, 1-1/2" TOP SPUD, SCREWDRIVER STOP, VANDAL RESISTANT STOP CAP. B URINAL 2" 1 1/2" 3/4" --- WALL KOHLER "BARDON" #K-4991-ET, VITREOUS CHINA, ELONGA T ED RIIVI, 3/ter' 1 UP SPUD, 14 RIM EXTENSION, (HIGH EFFICIENCY WASHDOWN ACTION 0.125 GPF. SLOAN, "OPTIMA", #8186-0.125, BATTERY POWERED INFRARED SENSOR ACTIVATED. 131 URINAL 2" 1 1/2" 3/4" --- WALL KOHLER "BARDON" #K-4991-ET, VITREOUS CHINA, MOUNT FLUSH VALVE ELONGATED RIM, 3/4"TOP SPUD, 14"RIM HANDLE, PER A.D.A. EXTENSION, 'HIGH EFFICIENCY WASHDOWN /ANSI STANDARD ACTION 0.125 GPF. SLOAN, "OPTIMA", #8186-0.125, BATTERY POWERED INFRARED SENSOR ACTIVATED. C1 LAVATORY 1 1/2" 1 1/2" 1/2" 1/2" WALL KOHLER "CHLSAPEAKE" #K-1729, 20"X18", PROVIDE TRUEBRO "SOFT- fL VITREOUS CHINA LAVATORY, 4" FAUCET CENTERS, GUARD PLUS" INSULATION KIT OVERFLOW, DRILLED FOR CONCEALED ARM CARRIER, ADA COMPLIANT. SLOAN, #EAFI-150-BDT, BATTERY OPERATED, SENSOR ACTIVATED, THERMOSTATIC MIXING VALVE, ASSE 1070, 1/2" SUPPLY ADAPTERS, METAL GRID STRAINER, ALL BRASS BODY, CHROME PLATED, 4" TRIM PLATE, 0.5 GPM AERATOR. TRUEBRO #102-W, INSULATION KIT FOR TRAP AND SUPPLIES. C2 LAVATORY 1 1/2" 1 1/2" 1/2" 1/2" WALL BRADLEY 2-STATION "VERGE" LAVATORY SYSTEM NOTE: COLOR OF BOWL #LVSD2-SSD,_ELONGATED BASIN CONSTRUCTED SELECTION BY THE OF "EVERO" NATURAL QUARTZ SURFACE, WITH 2 ARCHITECT. LAVATORY STATIONS AT 30" ON CENTERS, STAINLESS STEEL PEDESTAL ACCESS PANEL AND SUPPORT FRAME. BRADLEY, #IR-DCD-TMA, DECK MOUNTED INFRARED BATTERY FAUCET, (2) TWO NO TOUCH INFRARED FAUCETS, SOLID CAST BRASS CONSTRUCTION. ALL ELECTRONICS SHALL BE WITHIN WATERTIGHT ENCLOSURE. FAUCET SHALL INCLUDE THERMOSTATIC MIXING ASSEMBLY TEMPERATURE I URE CONTROL, 0.5 GPM AERATOR, AIVD STAINLESS STEEL FLEXIBLE HOSES. BRADLEY, #6315-KT0000, BATTERY INFRARED ELECTRONIC: SOAP DISPENSERS AND BOTTLE C3 LAVATORY 1 1/2" 1 1/2' 1/2" 1/2" WALL BRADLEY 3-STATION "VERGE" LAVATORY SYSTEM NOTE: COLOR OF BOWL #LVSD3-SSD�ELONGATED BASIN CONSTRUCTED SELECTION BY THE OF "EVERO" NATURAL QUARTZ SURFACE, WITH 3 ARCHITECT. LAVATORY STATIONS AT 30" ON CENTERS, STAINLESS STEEL PEDESTAL ACCESS PANEL AND SUPPORT FRAME. BRADLEY, #IR-DCD-TMA, DECK MOUNTED 1"14F!�"RED F,-\UCET BATTERY, (3) I1 11— I- TOUCH INFRARED FAUCETS, SOLID CAST BRASS CONSTRUCTION. ALL ELECTRONICS SHALL BE WITHIN WATERTIGHT ENCLOSURE. FAUCET SHALL INCLUDE THERMOSTATIC MIXING ASSEMBLY TEMPERATURE CONTROL, 0.5 GPM AERATOR, AND STAINLESS STEEL FLEXIBLE HOSES. BRADLEY, #6315-KT0000, BATTERY INFRARED ELECTRONIC; SOAP DISPENSERS AND BOTTLE D 1c;IN(7I_F BOWL 11191, 1 1/2" 1/�" 11/2" COUNTER ELKAY "LUSTERTONE" #LRAD221965PD, 18 GAUGE, PROVIDE TRUEBRO "SOFT- -..-________ SINK . ..� .._ .._ .._ TYPE 304 STAINLESS STEEL SINK, SELF RIMMING, GUARD PLUS11 INSULATION KIT (GENERAL USE) (3) FAUCET HOLES, 22"x19"x 6.5" DEEP BOWL, PERFECT DRAIN, STRAINER AND TAILPIECE. T&S #B-2866-05 SWIVEL/RIGID GOOSENECK FAUCET WITH WRIST BLADE HANDLES, 1.5 GPM FLOW AERATOR E SINGLE BOWL 1 1/2" 1 1/2" 1/2" 1/2" COUNTER ELKAY "LUSTERTONE" #DRKAD371740 R/L PROVIDE TRUEBRO "SOFT - SINK (3) FAUCET HOLES, 4" DEEP SINK BOWL, #LKAD-18 GUARD PLUS" INSULATION KIT (CLASSROOM STRAINER AND OFFSET TAILPIECE, 3"DEEP WITH BUBBLER) FOUNTAIN BOWL #LKAD-8 STRAINER AND OFFSET TAILPIECE, #ILKR1141A BUBBLER WITH FRONT PUSH BUTTON WHICH SHALL BE MOUNTED IN COMPLIANCE WITH ADA/ANSI REQUIREMENTS. BUBBLER SHALL BE 5"MAX FROM FRONT AND SHALL BE OPERABLE AT 5 POUNDS MAXIMUM FORCE. T&S #B-2866-05, SWIVEL/RIGID GOOSENECK FAUCET WITH WRIST BLADE HANDLES, 1.5 GPM FLOW AERA17OR. F SINGLE BOWL 1 1/2" 1 1/2" 1/2" 1/2" WALL ELKAY, #WCILWO1923OSD, 18 GAUGE, TYPE 304 PROVIDE TRUEBRO "SOFT - SINK STAINLESS STEEL SINK, SELF RIMMING, SINGLE GUARD PLUS" INSULATION KIT (HAND SINK) FAUCET HOLE, 19"x 23"x 4" DEEP BOWL, #LKAD174 DRAIN, #LKF298 OVERFLOW ASSEMBLY, CHICAGO #116.975.AB.1, SINGLE HOLE, 5-1/4" FLOW CONTROL RIGID / SWING GOOSENECK SPOUT, SELF SUSTAINING POWER SYSTEM, STAINLESS STEEL HOSES, THERMOSTATIC MIXING VALVE, ASSE 1070 1.5 GPM LAMINAR FLOW CONTROL G SINGLE 1 1/2" 1 1/2" 1/2" 1/2" FLOOR ELKAY #E1C20X20-0X, 12" ECONOMY SERIES SINK, INSTALL WITH "SI" COMPARTMENT WITH ONE COMPARTMENT, 20"x20"x12" BOWL, NO J.R. SMITH #8710 SINK DRAINBOARD, 9" BACKSPLASH, 18 GAUGE, 300 SOLID INTERCEPTOR (ART ROOM) SERIES STAINLESS STEEL TOP AND BOWL, IN LIEU OF "P" TRAP. GALVANIZED LEGS & ADJUSTABLE FEET, RAISED 1-1/2" ROLLED EDGE, INCLUDES 3-1/2" BASKET STRAINER, NSF APPROVED T&S #B-0331.-CR4-L22, SWIVEL/RIGID GOOSENECK "SOFT - FAUCET WITH WRIST BLADE HANDLES, 1.5 GPM GUARD PLUS" INSULATION KIT GUARDPROVIDE US" INSUBROLATION FLOW AERATOR. H SINGLE 1 1/2" 1 1/2" 1/2" 1/2" FLOOR ELKAY #E1C:20X20-0X, 12" ECONOMY SERIES SINK, COMPARTMENT WITH ONE COMPARTMENT, 20"x20"x12" BOWL, NO SINK DRAINBOARID, 9" BACKSPLASH, 18 GAUGE, 300 SERIES STAINLESS STEEL TOP AND BOWL, GALVANIZED LEGS & ADJUSTABLE FEET, RAISED 1-1/2" ROLLED EDGE, INCLUDES 3-1/2" BASKET STRAINER, NSF APPROVED T&S #B-0331-CR4-L22, SWIVEL/RIGID GOOSENECK FAUCET WITH WRIST BLADE HANDLES, 1.5 GPM FLOW AERATOR. CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 i F� l I i i ' f- MECNAN/CAL AND ELECTRICAL ENGINEERING 750 OLD NA IN STREET SUME202 ROCKY HILL, CT 06067 P. (860) 436-4336 F. (860) 436-4450 www.mlesignassociafes,com '1111111101 .- e G NO. 252 9 f NS Mu"SER PIL"'N NELS(__')Na 1k ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 5 6 3 - 6 1 6 4 TITLE PLUMBING SCHEDULES DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. Pff"15.1 0 0 N L �C L U N O ^L LL z GENERAL NOTES: 1 PROVIDE SEISMIC DUCT JOIN WHERE DUCT PENETRATES SEISMIC JOINT. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 0 0 I - I I VISUAL ARTS CLASSROOM 91--9 PFAMNP7 16"o 0 0 N L a� E z U N O D_ z n Z AA BB DD FF HH H. KK PP QQ RR TT TT MECHANICAL DUCTWORK FIRST FLOOR - SOUTH 1 /8 11 = 1 1-011 C TOIL 13i 1 MECHANICAL DUCTWORK FIRST FLOOR - NORTH M1.1 1/811 = 11-011 ",OAOI-bki REVISIONS CONFORMED SET MARCH 22, 2019 2 2/21/19 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 I� O o 0 ww ww A w MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SMITE 202 ROCKY HILL, CT 06067 Pr (860) 436-4336 F. (860) 436-4450 www.rzdesignassociates.com 0t�tuttt tttti���� C0'444 ti /e � • t4 9� �, � N0. 25239 MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL DUCTWORK FIRST FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. M191 MAIN DUCTWORK IN - T _ GYM TO PITCH I PARAI I F_1 Tn RnnF= WITHIN BEAM POCKETS. BRANCHES SHALL BE INSTALLED WITHIN THE I I } TRUSS BAYS. ALL I GYMNASIUM DUCTWORK SHALL BE - - - - SPIRAL WITH 1"DUCT ! I LINER. SEE DETAIL 5 ON M4.2 FOR SPIRAL DUCT DETAIL. (TYP) - kiff F�1-- \ M I I - I 14' 1- I I I I I 77f— i I I I � I MECHANICAL 114 I 11 14x14 EA UP — — C 5x6 TO EF-4 2 TERMINATE �` / IN ELEC Y T 11 ROOM WITH 1/2"x1/2" 6x4 WIRE MESH I C 6x6_ — SCREEN A 6 re — I — —20 5 — MAIN ELECTRICAL 6x6 F!✓ 113 E 6x6 TOILE' r 112 (EF4 75 6x4 C 18x18 I OUTDOOR EQUIPMENT 9O0 STORAGE GENERALSTORAGE Ij 119A� 111 _ — I — C 6x6 40 EF-3 12x4 50 8x4 — -, — 18x18 MA UP TO \ \ C L - 'GOOSENECK ON ROOF - - GENERAL NOTES: 0 PROVIDE SMOKE DETECTORS IN SUPPLY AIR DUCTWORK OF ALL AC UNITS AND DOAS UNITS. SMOKE DETECTOR SUPPLIED BY ELECTRICAL CONTRACTOR, INSTALLED IN DUCTWORK BY MECHANICAL CONTRACTOR ANn WIREn BY ELECTRICAL CONTRACTOR. O MOTORIZED DAMPER NORMALLY OPEN. INTERLOCK WITH KILN OPERATION TO CLOS DAMPER WHEN KI N IS TI KI T ON. O KILN EXHAUST SYSTEM CONSISTING OF PLENUM CUP ATTACHED TO BOTTOM OF KILN SPRING LOADED CUP 1 STAND, HOSE CLAMPS, 2" FLEXIBLE HOSE, EXHAUST FAN AND MOUNTING PLATE PROVIDED BY OTHERS. U PROVIDE 3"x8" DUCT FROM DISCHARGE OF EXHASUT FAN UP THROUGH ROOF. TERMINATE WITH GOOSENECK. COORDINATE EXACT LOCATION OF EXHAUST FAN WITH ARCHITECTURALS DRAWINGS. I II I h I D 24x10 C 6x6 C 24x12 800 20 800 VESTIBULE 189 'J F 8x6 D 42x38 - 5250 - I 1 � 6!!O -Ar-t-JP - - :T- - 36x18 RA UP STODIAL STORAGE, TO AC-2 1 66 AIR STORAGE 6x6 D 6� 1-1 �� �� vvo, vvv I n G H J OK © M NN © Q R OT U V X .4 i I i I I I i i KEYPLAN STATE PROJECT NO. I I I I I I I I I I LL 132-0089 N III lI „ col PHASE 2 OF 5 '� ©,® III II■® �� �. �� jl `�� GYMNASIUM VESTIEWLE FBI .. EllOrd SOCIAL WORKER EEO I aomi ® Eli _ ... ;• o i I ' � - a,��'•• ,w.y, it 1 _ � �'■Q r�'�f- IN Ill •�. Rom •1 "� • • . , �IUI•I ©• • p� % �� I • . GENERAL MUSIC - 12x6©• Nil Flo • •' +..... > �������� ® ���► r.. ��� .: 1 • •• �. -�_ .�. � ©® I � _ • I �■ - _• • '� ' I ' • ''i1 I�■ e„j �� • : • r �I]iJiia�l•� ■� I_ �\t"1I _'—I®_ •-- ••- �� ,��.fi�� p � . � ,�I'■lam • ,� Q� I �7r l -��,C� =�■moil -. -- - A • y � � o = -' - - -_�-- - . . �,®i .. �■���® o� �--� III �!■�I � ' ��fl I �� � � 11�, ■I ►��-- r► 1 - - — — ■ ffirl .• — I _ � •_ ��, - .. •11 _ .. Ise = _� � ' �-__�___ lei �4 .J ■ o o •12x12 EA UP TO EF-6 prWARS sum 0� • 11 i _ I I _ ■ © �I KITCHEN r II � • I 1 ' ' ► ��� © . I fir. , ■ �] ilrr'�I ��••. , �;� ••. I■C7i1 �' — — — rri7 `III I{a!•% �' • � 1 I .� tee. • • � ► \ � a �© . ����, 1 t a0]IN 1 � lli7d.' I _ �� I I I r ' lil ' mm �'—!.!:7 ®tom j: 1■ ►'_I , --4� MECHANICAL DUCTWORK FIRST FLOOR - WEST 1 /8" = 1'-0'r MEDIA CENTER OFFICE srm IO� ■ ''r..l• s� all - 650 • 1Il 0 o = _ 11 ■� ® 164 { 1.1 � �� •, • M Q�ZII — [am Ell 0 .. '17FC2-1:?F u 11 '' — — F .. T 1 O � � o Ww� N � �x 0177 � A d' N O a Ih`-II Y--'1 GENERAL NOTES: 1 PROVIDE SMOKE DETECTORS IN SUPPLY AIR DUCTWORK OF ALL AC UNITS AND DOAS UNITS. SMOKE DETECTOR SUPPLIED BY ELECTRICAL CONTRACTOR, INSTALLED IN DUCTWORK BY MECHANICAL CONTRACTOR, AND WIRED BY ELECTRICAL CONTRACTOR. T V X 4 Z ®� BB DD FF HH H. T PP Q RR TT � I I I I I I I I !I I I I I I I I� I III II D3I8"j L3-9 I r I ! M 112x8 I ! ! - - - - 12 — — � 13 C IDOR Lam, 282 16x6 I I I I ! I I I I I I B 40014 SOUTH TIAIR B 11 nn 8 ! I Fn M �' i\ I LJl b `I o o I I I - - - - - N-28x10- N IDF M I I - 211 C RADERS -M- 40x10 • 550 LI -11 ❑ 20 I I IELEV. B 10x10 I I (TYP 2) I I I 16 I I I I I II C 124X12 D 24x10EL-1 280 !Fc4-1 800 20 800 A1"o I I I � 6x4 I I I 34x14 I 42x12 I I ! r-D3-10 ! ! ! ALCOVE 12x8 M 17 -- _ - 18 ILET • vv' D3-11 � — I I I I i I 2 4 I I T B 6x6 ! I I I 19 O — — — — — E 6x6 — - 47 I TOILS T30 ( 4-10B) 6x4 A 6"0 _ sz.,a st.,c 20 20 I � l�6x4 cvnv cvnv i INSTRUCTIONAL 12x6 STORAGE FC4-10B 21 - I- - o - I- - - I -- I - X - " �- CO 00 A 10 — ! — — GENE LSTORAGE _ 280 _ _ — -- - - - - -- - - I A 8"0 B-T OYS' TOILET EF-5 2 RP) � 175 L /I L ------ ! A 12"o x 8 E 9x9 23 - - �� — — — --- — —T11I_ din — _ — —t t— -I — t 241 25 CiA 28x8 FC4-11 x A 6 ! ! ! ! 8xl 26 217—: ffo°uxu SPECIAL EDUCATION RES URCE ROOM 12x12 UP TO EF-7 I I I I °� 2 1 I EArc-our AREA V i v/ E 9x9 ! I I I ! I I I I I I 81 (RP) 225 GIRLS' T 8" o B 12x12 A 8" o 420 — — — - - -! 1 F — 1 -i-- - I - -ED - 9 El V �r ffEIY I I i oo _ ' _ _ 3 1- -F - - I - - - - - - - - - _ - I I I I I I I I I I I I I , I ! I I ! ! ! I I i ! I I I I I I I I I I I ' I I I I I I I I I I I I ! I 1 I ! 41 1 I 1 I i 1 I i I I 1 i 0 MECHANICAL DUCTWORK SECOND FLOOR - SOUTH s� I I � Lh II I I MECHANICAL DUCTWORK SECOND FLOOR - NORTH KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 2 2/21/19 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE202 ROCKY IfILL, Cr 06067 P. (860) 436-4336 Fr (860) 436-4450 www.rzdesignassociates.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 5 6 3 - 6 1 6 4 TITLE MECHANICAL DUCTWORK SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO 1/811= 11-0t1 M1.3 1/811= 1'-Orr M1.3 18X18 TERMI GOOSI ROOF I--, R U�A FH i i 12 --� 13 \ 14 - 41 - 46 18, KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 1 2/19/19 BID SUPPLEMENT 1 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pr (860) 436-4336 F. (860) 4364450 www.mdesignassociates.com �v�Pp vv. c9`9��*i�C o � ✓CeNS3° MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL ROOF PLAN DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 2 1 MECHANICAL ROOF M1.4 3/32" = 1'-0" MIA REVISIONS CONFORMED SET MARCH 22, 2019 0 n 16x6 MECHANICAL DUCTWORK - ALTERNATE 1 1 /8" = 1'-0" VENTILATION CONTROL DAMPER SCHEDULE TAG ROOMS TYPE DESIGN MIN SIZE NOTES SERVED (CFM) (CFM) D3-12 210 VARIABLE 430 135 14x8 VOLUME D3-13 211 VARIABLE 430 135 14x8 VOLUME D3-14 212 VARIABLE 430 135 14x8 VOLUME VRF FAN COIL UNIT SCHEDULE TAG ROOMS SERVED TYPE CFM ESP TOTAL COOLING (MBH) SENSIBLE COOLING (MBH) HEATING (MBH) ELECTRICAL MANUFACTURER MODEL NO NOTES V PH MCA FC4-12 210 DUCTED 1100 0.2" 26.3 20.0 10.2 208 1 3.5 LG ARNU363BRA4 FC4-13 211 DUCTED 1100 0.2" 26.3 20.0 10.2 208 1 3.5 LG ARNU363BRA4 FC4-14 212 DUCTED 1100 0.2" 26.3 20.0 10.2 208 1 3.5 LG ARNU363BRA4 GENERAL NOTES T1A14? BB DD F HH I K PP Q RR TT UU i 1 I 21 MECHANICAL PIPING SECOND FLOOR - ALTERNATE 1 � M 1.5 1 /811 = 1'-011 i STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT06067 P. (860) 4364336 F. (860) 436-4450 www.rzdesignassociates.com N0.2523 MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ALTERNATE 1 - ADDED CLASSROOMS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. M1.5 I GENERAL NOTES: n PprwinE SEISMIC PIPE EXPANSION JOINTS WHERE PIPING U PENETRATE SEISMIC JOINT. SEE ARCHITECTURAL - DRAWINGS FOR EXACT LOCATION. II i I I i i I RP-2 26' - 011 l-�- n A 0.1 GPM l%n11A u.I vrrw I - i -7 I AA Bib DD F.F HH KK i � I - - I I' I RP-2 26- 0" 0.1 GPM ILill3/4"HWS 3/4"HWS 1 314"HWR 3/4"HWR i 1 1 1/4"HWS � - r----------I --- ---1 ----i --1 1/4"HWR----- ------- ----, hD i 111 I I I I rn• n I FC1-1 RP-2 26' - 0" i I � FC1-2 L 0.1 GPM I I �j KINDERGARTEN �j KINDERGARTEN I I 133 KINDERGARTEN I I I I I I 1/2" HWS&R j I RADIANT FLOOR L I 3/4"HWR I DISTRIBUTION TO EACH 0 I l KINDERGARTEN CLASSROOM - -1 1/4"HWR- - 3/4"HW _ _ 1 1 r 1 1/4"HWS-•�- r - _1 112"HWR- - - REFER TO ARCHITECTURAL _ 1 I I 1 1/2"�iWS I DRAWINGS FOR DETAIL /FINISHES ( ! _ FOR RECESSED MANIFOLD BOX. -3/4"HWS IET T T 3/4"HWR RP-2 4'- 0" C 0.5 GPM I I RECESSED _ „ J MANIFOLD BOX, 3/4 HWS I --� -3/4"H W R � � I -- - _ - - 11 S&R I j TUH/SQFT 1\ II 1117 A r TUvAT A •rIQ 7 - V A 111 ATNTT FT C)()R PT .AN RP-2 1 26' - 0" 0.1 GPM RP-2 1 4' - 0" 0.5 GPM Q� O C VF U U U � U D 0 ® ® Z AA BB DD? FF HH H. KK PP C�t� KK II I. I i I I I 2"HWS I I RP-1 12' - 0" ++ ( I ENGLIS 27 RNE 2"HWR RP-1 32' - 0" 0.5 GPM ( 121 IT 1.0 GPM 3/4"HWR I I 1-1/2" HWS&R UP ~ - _ I - - 12 FC1-1 SEE M2.3 FOR - I-- j 1 - - - I-_--- CONTINUATION - - =1 - 13 14 .`� I -- 3/4"HWS I � • ' I ROUTE PIPING DOWN I 3/4" HWS & R ROUTED i 2"HWS { UNDER STAIR TO CUH-7. 2"HW rolLEr I o IN CHASE. SOUTH STAI 101 ® I I I FC2-15 I CORRIDOR COORDINATE RADIANT CEILING r I � c - _ _ _ __ PANELS WITH ARCHITECTURAL I RP-1 24 - 0 CUH-3 CEILING. (TYPICAL) 1.0 GPM I 3/4"HWR I j RP-2 3/4 HWS -FC3-1 - - - 0.5 GPM IIII� VIpUAL ARTS I CLASSROOM 3/4"HWS RP-1 11 6' - 0" 0.5 GPM RP-1 1 6' - 0" 0.5 GPM PSYCHOLOGIST Ii �■ _ •INTER • ■I ENTION = 1 0.5 GPMVIA •„ ILN ROOM L �I��I■ . I 1.1 11 - - -- - - ice` �l • - I� I MIME 24 Ili�l� ,,© ■ II - ■ TEACHER WORKROOM TOILET .,. Illil � • •• a, ill 1. � - v ■ �- ■ r iw ■u ■��� iIil I� 1 ��1 I �I II III IU ►a ,'- ,■r-�-- �� _ I�t..•rz- ►LWA IWA OWN =0'153VA' �,I�� ♦�.�li9�`� Wiz■/ ill +---'--+--' - ■"-+- +� w- r' j Now S ♦ ♦ ► ♦ ��I ■� -11011 th 1 ■ETLRJAL AREA WI .1 � ♦♦ � .�� �► ♦ � . � of � �I�.1 LI 1�■ _ w' ♦ ♦ �' CONSULTATION ROOM 02 0.5 GPM 12' - 0" 0.5 GPM RP-1 10' - 0" I I 0.5 GPM I I RP-2 8' - 0" 0.5 GPM I 1i I j MECHANICAL PIPING FIRST FLOOR - SOUTH 3/4"HW3 R 2 Y FC2-8 I I RP-2 1 8' - 0 FC2-9 PRINCIPAL'S OFFICE II / MAIN OFFICE 0.5 GPM CONFERENCE ROOM 01 I 3/4"HWS 1-o11 0.5 GPM ' - O' I RP0.5 GPM REVISIONS I ---� CONFORMED SET PROJECT MARCH 22, 2019 NORTH 1 2/19/19 BID SUPPLEMENT 1 I r... .......-•. .-......... .. ----• ....� NORTH 2 2/21/19 BID SUPPLEMENT 2 U - RP-1 24' = 0" 1.0 GPM I 1.0 GPM 1.0 GPM jr3/4-HV %WS11 WEb I SOUTH oCONNECT PANELS TbGETHE 3/4"HWS WITH 3/4" HWS AND ISOLATION �-- 3/4"HWRR 3/4"HI i r1i VALVE. I I I �---�---------�- ------ T------------------------1 0 3/4" HWS -- -- 1 1/4"HWR I KEYPLAN -- 1 1/4"HWS KINDERGARTEN I I I I ( STATE PROJECT NO. o KINDERGARTEN 132 I KINDERGARTEN ' 132-0089 N ° I FC1-1 FC1-2 I FC1-3 I " I RP-1 26' - 0" 3 PHASE 2 OF 5 I RP-1 26 - 0 I - i - -.� - � � 1.0 GPM M2.1 1.0 GPM I I I L` ,� I i I i II ° II I �, I I I I I I 13/4"HWS • 3/4 HWR 0 1 I I--------- T-� 3/4"HWR ---- -- I 1 5/ZWS I I -(- - -, I I 3/4"HWS RP-2 4' - 0" RP-2 4' - 0" � ' I C C C rol ET I 0.5 GPM 0.5 GPM TOILET TOILET o ® it - - �� II - - 1 1/2"HWS _ - -- - I - 1 -- i� - - -- - - - 1 1/2"HWR 0 � - - - - - I 5 �° 3/4"HWR- -- v s194 3/4"HWS T .......•.•�...�. -III CUH- rnnonlnlATG (^I IN 1 nC ATl(1NS ! I I CORRIDOR I I � I VVVI\V11 Y/ IL VVl l �v v, ...v,.. I I I 11921 I , , , WITH ARCHITECTURAL I'97TPP ILY I I I I FC1-17 -111 ROUTE HWS & R IN CEILING GRID. (TYPICAL) 3I4"HWR I HR1-4 I ! II \ \ SOFFIT. I � I NORTM STAIR I I I I �/ CUH-1 I 1 1/4"HWR-I 1 FC1-9A 1 1/4"HWS (CUH-2) 3/4" HWS & R DOWN TO CONTROL AND ISOLATION - VALVES SHALL BE LOCATED T i I- ! T CUH AT LOWER LEVEL. ON WARM SIDE OF ENTRANCE. -_ - _ _ _ (TYPICAL) - J 1 1 - I - I 1 - -- 6 TOILET TOILET U 1�35 3/4"HWR _ 3/4"HWS I I �f 1 I 1 I I I i I l I FC1-4 I I I 1 1 I GRADES 1-2{ I I I GRADES 1-2 I I I RP-1 28`-0" I CLASSROOM CLASSROOM 1 " 1.0 GPM I 131 11 RI-1 I I I 13$ RP 1.0 GPM - 0 ® �' I FC1-5 I � I I � I _ I I r ...... rI I -1 lift � lb�I 11 I --- 1 1/4"HWS - -E- _ _ - NN I I � I 3/4"HWR 3/4"HWS I I I � T I T 111HVVRJ HWSn '--+ - ---- TOILET Ih36A1 I 3/4"HWS I � I - 3/4"HWR SEE DETAIL SHEET M5.2 FOR EXPANSION GM S p-z I I V LOOP DETAI -) CLAS® M I J FC1-6 I I I 1 I I I I FC1-7 I GRADES 1.2 RP 1.0 GPM-011 � - � I I I --- - �-- f CLASSROOM I I - j RP 1.0 GPM 28,= 0:: $ � � I I I 11 I HR1-2 3/4", 1-1/8", 1-3/8" RL UP SEE SHEET M2.3 FOR I F- 3/4"HWR I CONTINUATION 3_/4"HWS 4 IT c T T - - ' rr+•I i _ i III I i I LI J nrnul nnln MECHANICAL AND ' I L �� I •- ��� nvvr� t I 3/4 HWS i I I I it { I I ELECTRICAL ENGINEERIN750OLD MAINSSTRGT I I I GRADES 1-2 I -- - I SU/TE202 CLASS ZOOM ROCKYH/LL, CT06067 P. (860) 436-4336 II FC1-8 I I i I I F. (860) 436-4450 www.rzdeslgnassociates.com RP-1 28' - 0" i 1 I RP-1 28' - 0" 1.0 GPM I CLASSROOM 1.0 GPM cr-- I I --� 1 I I I I I FC1-10 I ��\ ltIi I pp/, 1 vvC,� 3/4"HWS I ��O ``NO 25239 3/4"HWR . E +00� f h TOILE - - F61-11 ( � I 3/4"HWS I I1 HR1-3 , I I 3/4"HWR 0.5 GPM F61-913 I MATH INTERVENTION I _ I 7z� ! I - - 3/4"HWR I r 3/4"HWRI i 1 1/2"HWR I - 1"HWS I MOSER WAI-- 1 1/2"HWS C I I I I I RP-1 28' - o" PIL(N -� T NELSO �� 1 1 I I GRADES O 1.0 GPM 3/4"HWS -- ! I --" I CLASSROOM I 2"HWS , I 139 ENGLISH LEARNE , I 2"HWR J A R C H I T E C T S RP-1 12' - 0" I 11 FC1-13 A II 1z7 T I ( I I I 12 30 JORDAN LANE 0.5GPM I I WETHERSFIELD, CT. 06109 1-1/2" HWS&R UP ~- I / (860) 563-6164 3/4"HWR _SEE M2.3 FOR ' FC1-1 ' r - - _ _CONTINUATION OCT ROUTE PIPING DOWN Imo/-;3/4' HWS & R ROUTED i 2"HWS i 3/4 HWSI 1 I 14 TITLE UNDER STAIR TO CUH-7. 2"HW , MECHANICAL IN CHASE. I I SOUTH STAIRti I To® FC2-15 I ( PIPING FIRST CORRIDOR ' 191 FLOOR PLAN- - NORTH AND SOUTH I I > CUH-3 I �I I I I -1- ' 3/4"HWR I I � I 1 MECHANICAL PIPING FIRST FLOOR - NORTH M2.1 1/8" = 1'-011 DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. 1 /811 = 11-011 M__2 * I 0 C I I I ° I ° ' I I i I rti- - - - UH-1 _ — i CUH-7 MECHANICAL � I IT VESTIBULE I 144 3/4"HWS&R 1 11 TO UH-1. M6.1 T • � � � r�ulnrc ?- �1' � REVISIONS CONFORMED SET MARCH 22, 2019 2 2/21/19 BID SUPPLEMENT 2 G BOO H J ® © M N P Q ® T O KEYPLAN STATE PROJECT NO. I I I I I I I I 3 RP-1 32' - 0" I PHASE 2 OF 5 13 TOILET 12 I - \J 1/G 1 1"IJ 1/2"HWR 34 I + • -� GPM THROUGH L17J CUH-5 MECHANICAL 3/4"HWS . .... RADIATORS --- — - REFER TO ARCHITECTURAL;,, ELECTRICAL I _ _LI A 'DRAWINGS FOR DETAIL / FWISHES ENGINEERING c 2 2 T ! - FOR RECESSED MANIFOLD BOX. Aso OLD MAIN STREET j I MEDIA CENTER ° ( WORKROOM x' % `y" SUITE202 I !I CUSr DIAL OFFICE I ! _ j R-1 24 - 0�� - 04c RECESSED MANIFOLD BOX. ROCKYHILL, CT06067 436-4336 — — — — — — — -- 4.5 GPM F. (860) - — - - -- — - 41 P. (860J 436-4450 ft--- FC3-11 I I _ .,—„ —m / \_I wwH,rzdesignassociates.com - 46 MECHANICAL PIPING FIRST FLOOR - WEST 1 /811 = 11-011 co 11:1z ti NO.252 MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL PIPING FIRST FLOOR PLAN - WEST DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. M2*2 a rkm KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 2 2121/19 BID SUPPLEMENT 2 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 I � I I i I I I I I I O I 1777 I I I I I I I I I I I I I I I iw �ir1 A U V 4 Z BB DD FF H iH KK PP QQ RR TT i ., ,,. - J I r� I�■rl I I I I I I I it II � � i I In � � j I 1" rnrrr�c HWS&R CAPPED 4inu uro �noo r�nI I I I o _� Si �I O1�1�IIJ TI i t I I I �� 1%^ 1-u/- nvv0ar, U11 rUf'[ rV 1 Vr[C I I SEE M2.1 FOR I I I CLASSROOMSI � T? I I — 6 w 1 1/4"HWS ram, �r?FC4-10A— ---- --- — 1------- ' ---� 3/4"HWS l i 11/4"HWR O I I R4-5 FC4-2 I I FC4-3 I rT ' - RP-1 28' - 0" RP-1 28 0 F-�-1 Ico 1.0 GPM I I i 1.0 GPM GRADES 3-5 FGRADES 3-5 i CLASSROOM I CLASSROOM d-�d I I 209 � 21 I I , I V1 i I I I I I � i (7 �1 CORRIDOR 282 I 3/4 HWS C T T C 3/4"HWR • IT: u':4_ T C 3/4"HWR _�- I r 7 3/4 HWS 1 "HWS I I I I I I I 1"HWR M� HR4-3 I I GRADES 3-5 I GRADES 3-5 I I CLASSROOM FC44 I cLA 2S400M MECHANICAL PIPING SECOND FLOOR - SOUTH 1/811 = 1'-011 I I I I I I GRADES 3-5 CLASSROOM CORRIDOR 217 282 1 MECHANICAL PIPING SECOND FLOOR - NORTH M2.3 1/811 = 11-011 MECHANICAL AND ELECTRICAL ENG/NEER/NG 750 OLD MAIN STREET SUITE 202 ROCKYHILL, cT06067 P. (860) 436-4336 F. (860) 436-4450 www.mdesignassociates.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL PIPING SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. M293 REVISIONS CONFORMED SET MARCH 22, 2019 HP-1 (388.71 kBtulh) (394.29 kBtu/h) Additional refrigerant: 71.30 Ibs 3/4:1 +1 /8:1 +5/8 60.0 ft(4) 3/4:1 +1 /8:1 60.0 ft(4) 1/2:7/8:1 +1/8 60.0 ft(0) 15/8:7/8:1 +1/8 20.0 ft(2) 5/8:7/8:1 +1 /8 60.0 ft(0) HR-1-3 9.8 ft(0) 1/4:1/2 9.8 ft(0) 1/4:1/2 9.8 ft(0) 1/4:1/2 9.8 ft(0) HP-4 (406kBtu/h) (45kBtu/h) ref Additional refrigerant: 47.05 .05 lbs 3/4:1 +1 /8:1 +5/8 30.0 ft(2) 3/4:1 +1 /8:1 +5/8 30.0 ft(2) 0 0 cv L a) E z U a z a H R-1-1 1 /2:7/8:1 +1 /8 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) H R-1-2 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) 3/8:5/8:3/4 40.0 ft(0) 40.0 ft(0) H R-1-4 3/8:5/8 FC 1-1 9.8 ft(0) ff�(28.80 / 22.84 kBtu/h) (29.61 kBtu/h) 24.20 (119 %) / 18.30 (124 %) kBtu/h 13.70 (216 %) kBtu/h 3/8:5/8 FC 1-2 9.8 ft(0) (28.80 / 22.84 kBtu/h) (29.61 kBtu/h) 23.80 (121 %) / 17.80 (128 %) kBtu/h 9.00 (329 %) kBtu/h 3/8:5/8 FC 1-3 9.8 ft(0) (28.80 / 22.84 kBtu/h) (29.61 kBtu/h) 24.20 (119 %) / 18.30 (124 %) kBtu/h 12.30 (240 %) kBtu/h 1/4:1/2 n FC 1-9A 9.8 ft(0) (5.97 / 4.38 kBtu/h) (6.14 0tu/h) 4.20 (142 %) / 3.85 (114 %) kBtu/h 2.40 (255 %) kBtu/h O FC1-4 (28.98 / 22.97 kBtu/h) (29.61 kBtu/h) 24.40 (118 %) / 18.90 (121 %) kBtu/h 9.50 (311 %) kBtu/h FC 1-5 (29.53 / 23.41 kBtu/h) (29.61 kBtu/h) 24.60 (120 %) / 19.30 (121 %) kBtu/h 9.10 (325 %) kBtu/h --[] FC1-17 = (22.84 / 16.88 kBtu/h) (22.91 kBtu/h) n 21.00 (108 %) / 17.80 (94 %) kBtu/h 22.30 (102 %) kBtu/h Stand-by 0 FC1-6 (28.98 / 22.97 kBtu/h) (29.61 kBtulh) 23.80 (121 %) / 18.30 (125 %) kBtu/h 8.80 (336 %) kBtu/h FC1-7 (28.98 / 22.97 kBtu/h) (29.61 kBtu/h) 23.40 (123 %) / 18.20 (126 %) kBtu/h 8.80 (336 %) kBtu/h � � n (28.98 / 22.97 kBtu/h) (29.61 kBtu/h) FC1-824.90 (116 %) / 19.40 (118 %) kBtu/h 9.10 (325 %) kBtu/h n FC1-10 O O (28 98 / 22.97 kBtu/h) (29.61 kBtu/h) _J 24.60 (117 %) / 19.30 (119 %) kBtu/h 9.20 (321 %) kBtu/h H R-1-5 1/4:1/2 FC2-15 20.0 ft(0) (16.21 / 11.80 kBtu/h) (15.82 kBtu/h) 13.00 (125 %) / 9.10 (130 %) kBtu/h 17.90 (88 %) kBtu/h 3/8:5/8 FC 1-14 9.8 ft(0) (19.62 / 14.35 kBtu/h) (19.80 kBtu/h) 18.30 (107 %) / 14.20 (101 %) kBtu/h 7.30 (271 %) kBtu/h 1/4:1/2 FC1-15 9.8 ft(0) � (9.97 / 7.29 kBtu/h) (10.06 kBtu/h) 9.60 (103 %) / 7.20 (101 %) kBtu/h 3.10 (324 %) kBtu/h 1/4:1/2 FC1-16 9.8 ft(0) (12.48 / 9.08 kBtu/h) (12.60 kBtu/h) 11.60 (107 %) / 8.60 (105 %) kBtu/h 3.90 (323 %) kBtu/h 0 o FC1-13 (30.02 / 23.80 kBtu/h) (29.61 kBtu/h) 23.40 (128 %) / 18.20 (130 %) kBtu/h 8.80 (336 %) kBtu/h FC1-11 O O (10.20 / 7.46 kBtu/h) (10.06 kBtu/h) 9.80 (104 %) / 7.20 (103 %) kBtulh 3.30 (304 %) kBtu/h 0 0 FC1-12 (10.20 / 7.46 kBtu/h) (10.06 kBtu/h) 9.80 (104 %) / 7.20 (103 %) kBtu/h 3.60 (279 %) kBtu/h FC1-9B IF ii /d 56 kBtu/h) (R 1d kPffit/hl 14.20(14 8 %) /3.85 (118 %) kBtu/h 2.40 (256 %) kBtu/h 3:7/8:1+1/8 HR-4-1 3/8:3/4:7/8 20.0 ft(0) 60.0 ft(0) 11 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) 3/8:5/8 9.8 ft(0) 5/8:7/8:1 +1 /8 H R-4-2 30.0 ft(0) HR-4-3 3/8:3/4:7/8 HR-4-5 (ALT 1) 80.0 ft(0) T93/8:5/8 FC4-12 (ALT 1) .8 ft(0) (30.28 / 24.01 kBtu/h) (34.57 kBtu/h) 26.30 (115 %) / 20.00 (120 %) kBtu/h 10.20 (338 %) kBtu/h 3/8:5/8 FC4-13 (ALT 1) 9.8 ft(0) f] 0 (30.28 / 24.01 kBtu/h) (34.57 kBtu/h) 26.30 (115 %) / 20.00 (120 %) kBtu/h 10.20 (338 %) kBtu/h 3/8:5/8 n FC4-14 (ALT 1) (n 9.8 ft(0) (30.28 / 24.01 kBtulh) (34.57 kBtu/h) 26.30 (115 %) ! 20.00 (120 %) kBtu/h 10.20 (338 %) kBtulh Stand-by i 1/4:1/2 nFC4-1OA 9.8 ft(0) (10.26 / 7.51 kBtulh) (11.75 kBtu/h) 9.50 (108 %) / 9.20 (81 %) kBtu/h 5.30 (221 %) kBtu/h 3/8:5/8 FC4-2 9.8 ft(0) 0 =(30.20 / 23.94 kBtu/h) (34.57 kBtulh) 26.30 (114 %) / 20.00 (119 %) kBtu/h 10.20 (338 %) kBtu/h 3/8:5/8 FC4-3 9.8 ft(0) (30.20 / 23.94 kBtu/h) (34.57 kBtu/h) 26.80 (112 %) / 20.70 (115 %) kBtu/h 10.00 (345 %) kBtu/h FC4-4 rug (31.20 / 24.74 kBtu/h) (34.57 kBtu/h) 27.90 (111 %) / 21.60 (114 %) kBtu/h 9.40 (367 %) kBtu/h n FC4-5 0 0 (31.20 / 24.74 kBtu/h) (34.57 kBtu/h) 26.80 (116 %) / 20.70 (119 %) kBtu/h 9.90 (349 %) kBtu/h �� n FC4-6 ff (31.20 / 24.74 0tu/h) (34.57 0tu/h) 28.90 (107 %) / 22.60 (109 %) kBtu/h 9.50 (363 %) kBtu/h 3/8:1 /2:5/8 H R-4-4 30.0 ft(0) 3/8.5/8 FC4-1 9.8 ft(0) (30.70 / 24.34 kBtulh) (34.57 kBtu/h) 27.20 (112 %) / 21.10 (115 %) kBtu/h 10.50 (329 %) kBtu/h 1 /4:1 /2 FC4-11 9.8 /2 (16.20 / 11.79 kBtu/h) (18.24 kBtu/h) 14.40 (112 %) / 11.80 ( 99 %) kBtu/h 5.50 (331 %) kBtu/h L-� Stand-by 3/8:5/88 FC4-8 9.8 ft(0) (31.32 / 24.83 kBtu/h) (34.57 kBtu/h) 28.00 (111 %) / 21.70 (114 %) kBtu/h 9.70 (356 %) kBtu/h 3/8:5/8 FC4-9 9.8 ft(0) (31.32 / 24.83 kBtu/h) (34.57 kBtulh) 25.80 (121 %) / 19.70 (126 %) kBtu/h 9.50 (363 %) kBtu/h 1/4:1/2 �,-,� n FC4-1OB 9.8 ft(0) (10.64 / 7.79 kBtu/h) (11.75 kBtu/h) 9.50 (112 %) / 9.20 ( 84 %) kBtu/h 5.30 (221 %) kBtu/h 3/8:5/8 FC4-7 9.8 ft(0) (31.32 / 24.83 kBtu/h) (34.57 kBtu/h) 25.80 (121 %) / 19.70 (126 %) kBtu/h 9.50 (363 %) kBtu/h HP-2 (209.68 kBtu/h) (208.00 kBtu/h) Additional refrigerant: 35.99 Ibs 5/8:1+1l8:1+3/8 40.0 ft(4) 2:7/8:1+1/8 60.0 ft(0) 3/8:5/8:3/4 30.0 ft(0) HR-2-1 3/8:5/8 20.0 ft(0) 1/4:1/2 40.0 ft(0) 1/4:1/2 30.0 ft(0) 1/4:1/2 3/8:3/4:7/8 20.0 ft(0) H R-2-3 3/8:5/8 30.0 ft(0) 3/8:5/8 30.0 ft(0) 1/4:1/2 20.0 ft(0) 1/4:1/2 O O FC2-11A (30.03 / 23.81 kB3tu/h) (29.94 kBtu/h) 27.70 (108 %) / 24.10 (98 %) kBtulh 13.60 (220 %) kBtu/h FC2-11 B 0 n (30.03 / 23.81 kBtu/h) (29.94 kBtu/h) 27.70 (108 %) / 24.10 ( 98 %) kBtu/h 13.60 (220 %) kBtulh FC2-6 (15.90 / 11.49 kBtu/h) (15.80 kBtu/h) 13.20 (120 %) / 10.80 (106 %) kBtu/h 4.60 (343 %) kBtu/h FC2-7 ° 20.0 ft(0) (12.82 / 9.32 kBtu/h) (12.74 kBtu/h) _� 11.60 (110 %) / 10.20 ( 91 %) kBtu/h 6.10 (208 /o) kBtu/h FC2-5 (20.32 / 14.87 kBtu/h) (20.02 kBtu/h) 18.40 (110 %) / 16.10 ( 92 %) kBtu/h 27.60 ( 72 %) kBtu/h FC2-10 O O (15.94 / 11.60 kBtu/h) (15.80 kBtu/h) 14.50 (109 %) / 12.80 ( 90 %) kBtu/h 7.40 (213 %) kBtu/h FC2-8 (10.30 / 7.45 kBtulh) (10.17 kBtu/h) 9.30 (110 %) / 7.10 (104 %) kBtu/h 5.20 (195 %) k:Btu/h FI FC2-9 50.0 ft(0) (6.24 / 4.49 kBtu/h) (6.20 kBtu/h) H R-2-2 3/8:1 /2:5/8 H R-2-4 60.0 ft(0) 1/4:1/2 20.0 ft(0) 1/4:1/2 30.0 ft(0) 1/4:1/2 5.30 (117 %) / 4.70 ( 95 %) kBtu/h 4.80 (129 %) kl3tu/h O O (15.85 / 11.53 kBtu/h) (15.80 kBtu/h) (6.20 / 4.55 kBtu/h) (6.20 kBtu/h) FF__n 40.0 ft(0) 1/4:1/2 rn� 9.8 ft(0) (4.68 ! 3.32 kBtu/h) (4.55 kBtu/h) 1/4:1/2 (T-n 9.8 ft(0) (6.38 / 4.59 kBtu/h) (6.20 kBtu/h) 9j8 ft(0) (6.38 ! 4.59 kBtu/h) (6.20 kBtu/h) 1/4:1/2 f�l 9.8 ft(0) (6.38 / 4.59 kBtu/h) (6.20 kBtulh} JHP-3 (177.48 kBtu/h) (184.01 kBtu/h) Additional refrigerant : 27.25 Ibs 18:7/8:1 +1 /8 j 20.0 ft(2) I 1/2:7/8:1 +' 40.0 ft(4) 3/8:1/2:5/8 60.0 ft(2) HR-3-1 3/8:3/4:7/8 1 3/8:3/4 9.8 ft(0) 1/4:1/2 I 9.8 ft(0) 1/4:1/2 9.8 ft(0) 1/4:1/2 9.8 ft(0) - H R-3-2 1/4:1/2 20.0 ft(0) 1/4:1/2 10.0 ft(0) 1/4:1/2 '0.0 ft(0) 50.0 ft(2) H R-3-3 3/8:5/8 FC3-1 9.8 ft(0) (30.79 / 22.79 kBtu/h) (32.18 kBtu/h) 30.90 (99 %) / 23.40 (97 %) kBtu/h 17.40 (184 %) kBtu/h 3/8:5/8 FC3-2 9.8 ft(0) (45.93 / 34.47 kBtu/h) (48.00 kBtu/h) 41.20 (111 %) / 28.40 (121 %) kBtu/h 4.40 (1090 %) kBtu/h 1/4:1/2 FC3-4 9.8 ft(0) (6.38 / 4.68 kBtu/h) (6.67 kBtu/h) 3.30 (193 %) / 3.10 (150 %) kBtu/h 2.60 (256 %) kBtulh o n FC3-3 (41.70 / 30.09 kBtu/h) (42.76 kBtu/h) 34.70 (120 %) / 26.40 (113 %) kBtu/h 15.70 (272 %) kBtu/h n FC3-6 (8.32 / 6.07 kBtu/h) (8.53 kBtu/h) 5.00 (166 %) / 4.70 (129 %) kBtu/h 4.70 (181 %) kBtu/h B--�� FC3-5 (4.77 33.38 kBtu/h) (4.89 kBtu/h) 3.10 (153 %) / 3.00 (112 %) kBtu/h 1.60 (305 %) kBtu/h n FC3-12 (6.50 / 4.77 kBtu/h) (6.67 kBtu/h) 5.70 (114 %) / 5.70 ( 83 %) kBtulh 2.40 (277 %) kBtu/h 1 /4:3/8:1 /2 H R-3-4 30.0 ft(2) FC2-2 14.60 (108 %) / 11.60 (99 %) kBtu/h 8.00 (197 %) kBtu/h FC2-13 4.90 (126 %) / 4.10 (110 %) kBtu/h 0.60 (1033 %) kBtu/h FC2-12 (6.18 / 4.45 kBtu/h) (6.20 kBtu/h) I_ 1 5.70 (108 %) / 5.20 ( 85 %) kBtu/h 2.20 (281 %) kBtu/h FC2-1 2.20 (212 %) / 2.20 (150 %) kBtu/h 0.70 (649 %) kBtu/h FC2-3 5.90 (108 %) / 4.70 ( 97 %) kBtu/h 0.70 (886 %) kBtu/h FC2-4 5.70 (111 %) / 3.50 (131 %) kBtu/h 0.60 (1033 %) kBtu/h FC2-14 4.90 (130 %) / 4.00 (114 %) kBtu/h 2.90 (213 %) kBtu/h 20.0 ft(0) 1/4:1/2 40.0 ft(0) (4.73 / 3.35 kBtu/h) (4.89 kBtulh) r-i (10.61 / 7.77 kBtulh) (10.93 kBtu/h) �>1 (8.26 / 5.94 kBtu/h) (8.53 kBtu/h) FC3-11 (4.67 / 3.31 kBtu/h) (4.89 kBtu/h) J 1.90 (245 %) / 1.50 (220 %) kBtu/h 1.40 (349 %) kBtu/h FC3-10 (4.64 / 3.29 kBtu/h) (4.89 kBtulh) 2.60 (178 %) / 2.20 (149 %) kBtu/h 3.30 (148 %) kBtu/h FC3-8 1.60 (295 %) / 1.60 (209 %) kBtu/h 0.40 (1222 %) kBtu/h FC3-7 9.10 (116 %) / 8.90 (87 %) kBtu/h 4.70 (232 %) kBtu/h 1 FC3-9 6.20 (133 %) / 5.30 (111 %) kBtu/h 8.80 ( 916 %) kBtu/h STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE202 ROCKYHILL, CT 06067 P. (860) 4364336 F. (860) 436-4450 www.rzdesignassocrates.com k , MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL RISER DIAGRAMS DATE 11/2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. M3.1 Slab Sensor Installation Slab Sensor Installation 4" Long Nominal 1/2' Type "K" Copper Sleeve -Capped (By Others) Sensor Element Cor 1 Locate coppers! between loops of tL 2. Locate Slab Sen Layout Drawings, 3. Insert sensor elel I ICI It VVILI I I ICai sensing grease for greatest accuracy and response. Installation, �— 5/8" Conduit w/Waterproof Cover (By Others) (By Others) Compacted Sub -Soil Base Tracking ghall ha certl irPri to insiilatinn every 48" - 60" with barbed staples. Tubing shall be positioned on XX" Centers in tracking Expansion joint cuts should not be deeper than 1.25" maximum - ^oncrete Slab etal Web or Rebar as specified 1/2" ComfortPro PEX-C Tubing nfortPro Plastic Tracking High Density Styrofoam Insulation nil Plastic Waterproof Membrane 3ravel Bed - or better as designed 1/4" Tile or equal 2" Mud Topping Pour nr 5/8" (nmfnrtPrn PFX Tubina racking to secure tubing 1" High Density Polystyrene Insulation Barbed Plastic Tracking Staples Compacted Sub -Soil Base \ Structural Slab Tracking shall be secured to insulation every 36-48" with barbed staples. Tubing shall be positioned on XX" Centers in tracking Expansion joint cuts should not be deeper than 1.25" maximum PEX Radiant Tubing Nominal 1/2" Copper Sleeve - Capped Sensor Element Sensor Leads Locate copper sleeve midway between loops ot` tubing. Insert sensor 10-12" into slab for accurate reading. Insert sensor element with heat sensing grease for greatest accuracy and response. Compacted Sub -Soil Base Wire Mesh must be positioned on chair carriers during pour. Tubing should be 3" maximum, and 1 3/8" minimum from finished surface. Tie -rap tubing to grid every 36" minimum Compacted Sub -Soil Base Tracking shall be secured every 36-48" with plastic staples 1 RADIANT FLOOR DETAIL M4.2 NTS Heated Slab 4" Concrete Floor Slab 1/2" or 5/8" ComfortPro PEX Tubing Nire Mesh Grid - flat sheets cut to fit hairs to Elevate Grid Vapor Barrier (6 mil or better) 4" Gravel Bed - or better as designed S & R Thermometers 2" Stone Slab Finished Floor ling Mortar Bed 1.25" to 2" Thick 1/2' or 5/8" %-U111fn LPro PEX Tublr lg 31astic Tracking to Secure Tubing Structural Building Layer Long Sweep Protective Elbow Balance Valves Return Shutoff Valves Supply Wall Brackets SS Manifold Barrels DAMPER EXTRACTOR - - Flow Gauges S&RCPS PEX SPIRAL DUCT SECTION 5 SPIRAL DUCT SECTION M4.2 NTS Purge/Drain Valves 3 Part Compression Connection SPIRAL DUCT FOAM GASKETING DOUBLE DEFLECTION INTERNAL DUCT INSULATION, WHERE SPECIFIED FLASHING OR MEMBRANE ROOFING CANT STRIP ROOF INSULATION ROOF DECK - INSULATION AT CENTER TOP OF DUCT SHALL RF 2" THICK AND SHALL TAPER TO SIDES OF DUCT. - - - --- -- _ 2" THICK CLOSED CELL EXTRUDED POLYSTYRE INSULATION BOARD MECHANICALLY FASTED DUCTWORK AND WITH SURFACE PROPERLY PREPARED TO ACCEPT MEMBRANE. PROPERLY SEAL (SMAC SEAL CLASS A) ALL JOI1 IN METAL DUCTWORK 1 ENSURE NO LEAKAGE. BIRD SCREEN W/ REMOVABLE FLANGE GOOSENECK TO TERMINATE 24" ABOVE ROOF (MAXIMUM) FASTENER AT TOP OF NAILER TO j SECURE ANGLE,INSIDE / DUCT AND FLASHING TO CURB / ATTACH EXTERIOR DUCT TO ANGLE WITH SEALER @ FASTENER CURB e INSIDE DUCT WITH MIN. 2" FLANGE 2 GOOSENECK THRU ROOF M4.2 12f1 = 11-011 PRESSUREINDEPENDENT CONTROL VALVE---,--- HWR----4, I nnnnlviAL AIR VENT \ I i HWS I i I HOSE END DRAIN VALVE - S I RAIIVEtl VVI I H WITH GASKETED CAP BLOWDOWN VALVE AND CHAIN HOSE BIBB, GASKETED CAP AND CHAIN CABINET UNIT HEATER PIPING DETAIL NTS SLOPE I/2" /FT -- 60 MIL MINIMUM THICKNESS SELF ADHERING MODIFIED BITUMEN MEMBRANE WITH REFLECTIVE FOIL FACE EQUAL TO j ALAUMAGUARD AS MANUFACTURED BY POLYGUARD PRODUCTS. I --- 6" MINIMUM LAP (TYPICAL) NOTE: DETAIL IS GENERIC AND NOT A SUBSTITUTE FOR THE NEED FOR MECHANICALLY FASTEN THE CONTRACTOR TO DETERMINE MEMBRANE ON BOTTOM OF PROPER QUANTITIES AND DUCT AND SEAL FASTENER LOCATIONS OF FASTENERS AND HEADS WITH MINIMUM 4"x4" SUPPORTS AND INSULATION MEMBRANE PATCH. SHOULD BE DETERMINED BY MANUFACTURERS REQUIREMENTS. 4 EXTERIOR DUCT INSULATION DETAIL GALVANIZED M4.2 NTS CONNECTORS AND FASTENERS - NE ITO DUCT NA ITS 0 —�l I 1-5/8" GALVANIZED SUPPLY & STRUT RETURN DUCTWORK (TYPICAL) 1-5/8" ANGLE SUPPORT 1-5/8" POST BASE ANCHORED BASE PLATE [BY DIV. 5 CONTR] COORDINATE LOCATIONS. - - ROOF NOTES: SUPPORT HEIGHTS VARRY WITH ROOF SLOPE AND SHALL BE FIELD VERIFIED. MAINTAIN 2'-0" MINIMUM ABOVE FINAL ROOF ELF""T'^"' [BY MECH. C, [BY DIV. 5 CC 1. ENTIRE EXTERIOR DUCT SUPPORT SYSTEM SHALL BE CONSTRUCTED OF A GALVANIZED UNISTRUT TYPE PRODUCT AND PRE -MANUFACTURED GALVANIZED FASTENERS AND CONNECTORS. 2. FURNISH LONGITUDNAL CONNECTION BETWEEN SUPPORTS. 3. BASE SUPPORT PLATE AND ALL FLASHING & COUNTER FLASHING SHALL BE PROVIDED AND INSTALLED BY THE DIVISION 5 CONTRACTOR. SUPPORTS SHALL BE SECURELY FASTENED TO CONCRETE DECK AS INDICATED. FOR NEW STEEL DECK ROOF, FASTEN SUPPORTS TO STRUCTURAL STEEL. 4. ROOF MOUNTED DUCT SUPPORTS SHALL BE INSTALLED WITHIN 24" OF ALL EQUIPMENT AND HORIZONTAL OR VERTICAL CHANGES IN DIRECTION. MAXIMUM SPACING OF ROOF MOUNTED DUCT SUPPORTS SHALL BE 8'-0". 5. FINAL DUCT ROUTING AND ROOF MOUNTED DUCT SUPPORT LOCATIONS SHALL BE COORDINATED WITH DIV. 5 AND ROOFING CONTRACTORS. 6 ROOF DUCT SUPPORTS M4.2 NTS REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 �d IND C 0 I I I II NECHAN/CAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKS' HILL, CT 06067 Pr (860) 4364336 F. (860) 436-4450 www.mdesignassociates.com MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL DETAILS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. M4*2 AIR DEVICE SCHEDULE MARK MANUFACTURER DUTY TYPE FACE SIZE NECK SIZE CFM MAX T.P. (IN WG) MODEL FINISH A KRUEGER SUPPLY LAY -IN 24"x24" AS NOTED AS NOTED AS NOTED 0.10 0.10 ASDP EG5 WHITE WHITE B KRUEGER RETURN LAY -IN 24"X24" AS NOTED C KRUEGER SUPPLY WALL MATCH DUCT AS NOTED AS NOTED 0.10 80 WHITE D KRUEGER RETURN WALL MATCH DUCT AS NOTED AS NOTED 0.10 EG5 WHITE E KRUEGER EXHAUST LAY -IN 12"x12" AS NOTED AS NOTED 0.10 EG5 WHITE F KRUEGER SUPPLY WALL 21OX4' 10" INLET AS NOTED 0.10 DFB WHITE G KRUEGER SUPPLY DUCT AS NOTED AS NOTED AS NOTED 0.10 5DMGDR WHITE CEILING DIFFUSER RUNOUT SIZING SQUARE NECK DIFFUSER RUNOUT/ NECK SIZE CFM RANGE 6x6 6" 0 0 -100 CFM 9x9 8" O 101 - 240 CFM 12xl2 10,10 241 - 400 CFM 15x15 12"0 401 - 600 CFM 18xl8 14" 0 601 - 800 CFM GENERAL NOTES: I. TAPS/RUNOUTS/NECK AS REQUIRED FOR CFM SHOWN DIFFUSER LEGEND 'A' 6" 0 NECK SIZE 500 GRILLE MARK FOR CUBIC FEET GRILLE SIZE SEE PER MINUTE DIFFUSER DETAIL DUCT SOUND ATTENUATOR SCHEDULE MAX OVERALL SIZE INSERTION LOSS TYPE & MODEL (IN) OCTAVE BAND FREQUENCIES TAG MFR NUMBER SERVICE TOTAL PRESS (Hz) SERVES (CFM) DROP (IN WG) W H L 63 125 250 500 1 K 2K 4K 8K DS-1 VIBRO ACOUSTICS IN LINE RD-MV-F7 SUPPLY 5400 0.25" 34 22 84 9 12 27 49 47 43 30 21 DOAS-1 DS-2 VIBRO ACOUSTICS IN LINE RD-MV-F7 RETURN 5000 0.26" 34 20 84 12 15 32 53 47 39 26 16 DOAS-1 DS-3 VIBRO ACOUSTICS IN LINE RD-MV-F2 SUPPLY 3350 0.23" 28 16 84 8 14 25 33 38 27 19 15 DOAS-2 DS-4 VIBRO ACOUSTICS IN LINE RD-MV-F5 RETURN 1500 1450 0.13" 0.16" 22 18 12 14 84 84 11 9 16 12 24 29 43F44 49 47 34 43 21 29 14 20 DOAS-2 DOAS-2 DS-5 VIBRO ACOUSTICS IN LINE RD-MV-F7 SUPPLY DS-6 VIBRO ACOUSTICS IN LINE RD-MHV-F8 RETURN 3300 0.18" 32 14 84 8 12 25 43 48 38 25 19 DOAS-2 DS-7 VIBRO ACOUSTICS IN LINE RD-MV-F6 RETURN 2150 0.20" 20 16 84 12 17 25 44 47 36 23 14 DOAS-3 DS-8 VIBRO ACOUSTICS IN LINE RD-MV-F4 SUPPLY 2260 0.13" 24 16 84 10 13 23 40 42 31 19 13 DOAS-3 nc_o VIBRO IN LINE Mr!'r, IMLI ,,,,,,,, ACOUSTICS RD-MHV-F8 RC I ur-.ry saau 0.-i9" s2 16 84 8 12 25 43 48 38 1 25 19 DOAS-3 DS-10 VIBRO ACOUSTICS IN LINE RD-MV-F1 SUPPLY 3750 0.25" 30 16 72 8 14 26 30 36 25 19 15 DOAS-3 DS-11 ACOUSTICSVIBRO RED HOV F7 SUPPLY 5250 0.23" 36 18 72 6 11 20 27 37 37 30 24 AC-1 DS-12 ACOUS VIBROCS RED HOV F7 RETURN 5250 0.23" 36 18 72 7 11 21 28 38 37 29 24 AC-1 DS-13 ACOUS VIBROCS RED HOV F7 SUPPLY 5250 0.23" 36 18 72 6 11 20 27 37 37 30 24 AC-2 DS-14 ACOUVIBRO ICS ELBW RED HOV F7 RETURN 5250 0.23" 36 18 72 7 11 21 28 38 37 29 24 AC-2 DS-15 ACOUSTICS VIBRED BOW SUPPLY 5250 0.23" 36 18 72 6 11 20 27 37 37 30 24 AC-4 DS-16 BRO ACOIUSTIICS ELBOW RED MHV-F7 RETURN 5250 0.23" 36 18 72 7 11 21 28 38 37 29 24 AC-4 GENERAL NOTES/ACCESSORIES: 1. ACCEPTABLE MANUFACTURERS BY: PRICE, AEROSONICS, INC., RUSKIN CO. HEAT PUMP SCHEDULE TOTAL TOTAL ELECTRICAL TOTAL MANUFACTURER MARK TYPE COOLING HEATING REFRIGERANT & NOTES (MBH) (MBH) (LBS) MODEL NUMBER V PH MCA MCOP AIR COOLED VRF HP-1 HEAT 408 459 460 3 35.7/38.3 50/50 140 LG ARUM408DTE5 (1) RECOVERY AIR COOLED VRF HP-2 HEAT 216 243 460 3 38.3 50 75 LG ARUM216DTE5 RECOVERY AIR COOLED VRF HP-3 HEAT 192 216 460 3 35.7 50 58 LG ARUM192DTE5 RECOVERY AIR COOLED VRF HP-4 HEAT 476 540 460 3 18.4/26.4/38.3 25/35/50 140 LG ARUM480DTE5 (2)(3) RECOVERY HP-5 SINGLE ZONE 24.0 27.0 208 1 18.1 30 4 LG LUU247HV (4) HP-6 SINGLE ZONE 24.0 27.0 208 1 18.1 30 4 LG LUU247HV (4) HP-7 SINGLE ZONE 38.0 43.0 208 1 18.1 30 9 LG ARUN038GSS4 NOTES: 1. COMBINATION OF MASTER LG ARUM216DTE5 & SLAVE LG ARUM192DTE5. SEPARATE ELECTRICAL CONNECTIONS. 2. COMBINATION OF MASTER LG ARUM216DTE5 & (2) SLAVE LG ARUM144DTE5 & LG ARUM121DTE5 . SEPARATE ELECTRICAL CONNECTIONS. 3. CONNECTED LOAD INCLUDES 90 MBH COOLING AND 120 MBH HEATING FOR FUTURE CLASSROOMS. 4. SINGLE ZONE UTILIZED FOR IDF/COMPUTER ROOMS. VENTILATION CONTROL DAMPER SCHEDULE TAG ROOMS TYPE DESIGN MIN SIZE NOTES SERVED (CFM) (CFM) D1-1 132 VARIABLE 430 135 18X6 (2) VOLUME 131-2 133 VARIABLE VOLUME 430 135 18X6 (2) D1-3 134 VARIABLE 430 135 18X6 (2) VOLUME MA A CONSTANT MULTIPLE VOLUME 5u 50 6X6 (1) Di-5 131 VARIABLE 390 115 18X6 (2) VOLUME D1-6 135 VARIABLE 390 115 18X6 (2) VOLUME D1-7 130 VARIABLE 390 115 18X6 (2) VOLUME D1-8 136 VARIABLE 390 115 18X6 (2) VOLUME D1-9 MULTIPLE CONSTANT 120 120 6X6 (1) VOLUME D1-10 129 VARIABLE 390 115 18X6 (2) VOLUME D1-11 137 VARIABLE 390 115 18X6 (2) VOLUME D1-12 128 VARIABLE 180 45 8X6 (2) VOLUME D1-13 127 VARIABLE 180 45 8X6 (2) VOLUME D1-14 138 VARIABLE 390 116 18X6 (2) VOLUME D1-15 139 VARIABLE 270 75 12X6 (2) VOLUME D1-16 140 VARIABLE 170 40 8X6 (2) VOLUME D1-17 141 VARIABLE 220 55 8X6 (2) VOLUME D2-1 MULTIPLE CONSTANT 335 335 10X8 (1) VOLUME 132-2 103 VARIABLE 80 30 6X6 (2) VOLUME D2-3 MULTIPLE CONSTANT 305 305 10X8 (1) VOLUME D24 104 VARIABLE 700 225 16X8 (2) VOLUME D2-5 MULTIPLE CONSTANT 850 850 16X10 (1) VOLUME D2-6 120 VARIABLE 940 120 18X10 (2) VOLUME D2-7 106 VARIABLE 580 150 16X8 (2) VOLUME 132-8 MULTIPLE CONSTANT 930 930 16X12 (1 ) VOLUME 133-1 MULTIPLE CONSTANT 60 60 6X6 (1) VOLUME D3-2 209 VARIABLE 430 135 12X8 (2) VOLUME (2) D3-3 213 VARIABLE 430 135 12X8 VOLUME D3-4 208 VARIABLEVOLUME 430 135 12X8 (2) 133-5 214 VARIABLE 430 135 12X8 (2) VOLUME 133-6 207 VARIABLE VOLUME 430 135 12X8 (2) D3-7 215 VARIABLE in VAR AR ws: ,�. - _ . _ VOLUME --- ' "" ' `^v 141 D3-8 206 VARIABLE 430 135 12X8 (2) VOLUME D3-9 216 VARIABLE 430 135 12X8 (2) VOLUME D3-10 214 VARIABLE 430 135 12X8 (2) VOLUME D3-11 MULTIPLE CONSTANT 655 655 16X8 (1) VOLUME NOTES: 1. BASIS OF DESIGN DADANCO PRESSURE INDEPENDENT CONTROL VALVES. 2 RV AT(` r()AITRA(`TrID SUPPLY TAG LOCATION AREA SERVED CFM OA TSP AC-1 ROOF GYMNASIUM 5250 2000 3.52 AC-2 ROOF GYMNASIUM 5250 2000 3.52 AC-3 ROOF KITCHEN 2400 300 2.60 AC-4 ROOF DINING 5250 1750 3.42 NOTES: 1. PROVIDE MINIMUM MERV 13 FILTERS. 2. FAN MOTORS TO BE PREMIUM EFFICIENCY AND VFD RATED. 3. UNIT CONFIGURED FOR DOWN DISCHARGE AND RETURN. 4. UNIT CONFIGURED FOR SIPE DISCHARGE AND RETURN. 5. UNIT TO BE WIRED FOR SINGLE ELECTRICAL CONNECTION. 6. PROVIDE GFCI DUPLEX SERVICE OUTLET. 7. GAS FURNACE TO HAVE MINIMUM OF 8:1 TURNDOWN RATIO. HEAT RECOVERY SECTION 1 MARK TYPE SUPPLY (CFM) EXHAUST (CFM) SUPPLY EXHAUST NOTES SUMMER WINTER SUMMER WINTER EDB EWB LDB LWB EAT LAT EDB EWB LDB LWB EAT LAT DOAS-1 PLATE 5400 5000 87.0 73.0 80.0 69.5 7 43.9 75.0 65.3 82.3 67.8 70.0 30.4 1, 2, 3 DOAS-2 PLATE 4800 4400 87.0 73.0 79.8 69.6 7 44.7 75.0 65.3 82.3 67.8 70.0 29.2 1, 2, 3 DOAS-3 PLATE 6000 5400 87.0 73.OT 80.3 69.6 7 42.9 75.0 65.3 82.1 67.6 70.0 30.4 1, 2, 3 AC-1 WHEEL 2000 2000 87.0 73.0 78.2 66.2 7 53.2 75.0 65.3 83.8 70.3 70.0 23.8 1,2 AC-2 WHEEL 2000 2000 87.0 73.0 78.2 66.2 7 53.2 75.0 65.3 83.8 70.3 70.0 23.8 1,2 AC-4 WHEEL 1750 1750 87.0 73.0 78.0 66.0 7 54.2 75.0 65.3 84.0 70.5 70.0 22.9 1,2 NOTES: 1. WINTER LAT IS EAT TO GAS FIRED HEATING SECTION. 2. SUMMER LDB/LWB IS EDB/LDB TO COOLING COIL. 3. HEAT RECOVERY SECTION IS INTEGRAL PART OF DOAS UNIT AND IS SCHEDULED SEPARATELY FOR CLARITY. VRF FAN COIL UNIT SCHEDULE TAG ROOMS SERVED TYPE CFM ESP TOTAL COOLING (MBH) SENSIBLE COOLING (MBH) HEATING (MBH) ELECTRICAL MANUFACTURER &MODEL NO NOTES V PH MC%A FG1-1 132 DUCTED 1100 0.2" 24.2 18.3 13.7 208 1 3.5 LG ARNU363BRA4 FC1-2 133 DUCTED 1100 0.2" 23.8 17.8 9.0 208 1 3.5 LG ARNU363BRA4 FC1-3 134 DUCTED 1100 0.2" 24.2 18.3 12.3 208 1 3.5 LG ARNU363BRA4 FC1-4 131 DUCTED 1100 _ 0-2" --- 7A A _ ... 120 ..,.,, a �..r ��o cvo a -50 .2.0 . ,.. �.., .., LG AKIMIU363BRA4 FC1-5 135 DUCTED 1100 0.2" 24.6 19.3 9.1 208 1 3.5 LG ARNU363BRA4 FC1-6 130 DUCTED 1100 0.2" 23.8 18.3 8.8 208 1 3.5 LG ARNU363BRA4 FC1-7 136 DUCTED 1100 0.2" 23.4 18.2 8.8 208 1 3.5 LG ARNU363BRA4 FC1-8 129 DUCTED 1100 0.2" 24.9 19.4 9.1 208 1 3.5 LG ARNU363BRA4 FC1-9A 192 DUCTED 200 0.2" 4.2 3.9 2.4 208 1 1.06 LG ARNU073BHA4 FC1-913 191 DUCTED 200 0.2" 4.2 3.9 2.4 208 1 1.06 LG ARNU073BHA4 FC1-10 137 DUCTED 1100 0.2" 24.6 19.3 9.2 208 1 3.5 LG ARNU363BRA4 FC1-11 128 DUCTED 280 0.2" 9.8 7.2 3.3 208 1 1.06 LG ARNU123BHA4 FC1-12 127 DUCTED 280 0.2" 9.8 7.2 3.6 208 1 1.06 LG ARNU123BHA4 FC1-13 138 DUCTED 1100 0.2" 23.4 18.2 8.8 208 1 3.15 LG ARNU363BRA4 FC1-14 139 DUCTED 520 0.2" 18.3 14.2 7.3 208 1 2.65 LG ARNU243BGA4 FC1-15 140 DUCTED 280 0.2" 9.6 7.2 3.1 208 1 1.06 LG ARNU123BHA4 FC1-16 141 DUCTED 360 0.2" 11.6 8.6 3.9 208 1 1.016 LG ARNU153BHA4 FC1-17 S102 DUCTED 850 0.2" 21.0 17.8 22.3 208 1 2.65 LG ARNU283BGA4 FC2-1 124 CASSETTE 240 0.0" 2.2 2.2 0.7 208 1 0.2 LG ARNU053TRC4 FC2-2 124B,C,D DUCTED 420 0.2" 14.6 11.6 8.0 208 1 1.0,6 LG ARNU183BHA4 FC2-3 123 CASSETTE 250 0.0" 5.9 4.7 0.7 208 1 0.2 LG ARNU073TRC4 FC2-4 124A CASSETTE 250 0.0" 6.7 3.5 0.6 208 1 0.2 LG ARNU073TRC4 FC2-5 180,181 DUCTED 520 0.2" 18.4 16.1 27.6 208 1 2.65 LG ARNU243BGA4 FC2-6 103 CASSETTE 400 0.0" 13.2 10.8 4.6 208 1 0.2 LG ARNU183TQC4 FC2-7 102,102A DUCTED 360 0.2" 11.6 10.2 6.1 208 1 1.06 LG ARNU153BHA4 FC2-8 101A CASSETTE 280 0.0" 9.3 7.1 5.2 208 1 0.2 LG ARNU123TRC4 FC2-9 101B CASSETTE 250 0.0" 5.3 4.7 4.8 208 1 0.2 LG ARNU073TRC4 FC2-10 101 DUCTED 420 0.2" 14.5 12.8 7.4 208 1 1.06 LG ARNU183BHA4 FC2-11A 104 DUCTED 1100 0.2" 27.7 24.1 13.6 208 1 3.5 LG ARNU363BRA4 FC2-11 B 104 DUCTED 1100 0.2" 27.7 24.1 13.6 208 1 3.Si LG ARNU363BRA4 FC2-12 104C CASSETTE 250 0.0" 5.7 5.2 2.2 208 1 0.2 LG ARNU073TRC4 FC2-13 104A,13 DUCTED 200 0.2" 4.9 4.1 0.6 208 1 1.016 LG ARNU073BHA4 FC2-14 124E CASSETTE 250 0.0" 4.9 4.0 2.9 208 1 0.2 LG ARNU073TRC4 FC2-15 S101 DUCTED 450 0.2 13 9.1 17.9 208 1 1.016 LG ARNU183BHA4 FC3-1 119 DUCTED 1100 0.2" 30.9 23.4 17.4 208 1 3.5 LG ARNU363BRA4 FC3-2 120 DUCTED 1800 0.2" 41.2 28.4 4.4 208 1 3.5 LG ARNU543BRA4 FC3-3 105 DUCTED 1600 0.2" 34.7 26.4 15.7 208 1 5.2 LG ARNU483138A4 FC34 184 DUCTED 200 0.2" 3.3 3.1 2.6 208 1 1.06 LG ARNU073BHA4 FC3-5 184B CASSETTE 240 0.0" 3.1 3.0 1.6 208 1 0.2 LG ARNU053TRC4 cr�_c ....,-v es:c wv r%1 V+TCP1 uu%. I r_u nnn cau u".2" OX 4.7 4.7 208 1 1.06 LG ARNU093BHA4 FC3-7 188 DUCTED 280 0.2" 9.1 8.9 4.7 208 1 1.015 LG ARNU123BHA4 FC3-8 117A CASSETTE 240 0.0" 1.6 1.6 0.4 208 1 0.2 LG ARNU053TRC4 FC3-9 190 CASSETTE 260 0.0" 6.2 5.3 8.8 208 1 1 0.2 LG ARNU093TRC4 FC3-10 110 CASSETTE 240 0.0" 2.6 2.2 3.3 208 1 0.2 LG ARNU053TRC4 FC3-11 109B CASSETTE 240 0.0" 1.9 1.5 1.4 208 1 0.2 LG ARNU053TRC4 FC3-12 182,183 DUCTEDT 200 0.2" 5.7 5.7 2.4 208 1 1.06 LG ARNU073BHA4 FC4-1 217 DUCTED 1100 0.2" 27.2 21.1 10.6 208 1 3.5 LG ARNU363BRA4 FC4-2 209 DUCTED 1100 0.2" 26.3 20 10.2 208 1 3.5 LG ARNU363BRA4 FC4-3 213 DUCTED 1100 0.2" 26.8 20.7 10 208 1 3.5 LG ARNU363BRA4 FC4-4 208 DUCTED 1100 0.2" 27.9 21.6 9.4 208 1 3.5 LG ARNU363BRA4 FC4-5 214 DUCTED 1100 0.2" 26.8 20.7 9.9 208 1 3.5 LG ARNU363BRA4 FC4-6 207 DUCTED 1100 0.2" 28.9 1 22.6 9.5 208 1 3.5 LG ARNU363BRA4 FC4-7 215 DUCTED 1100 0.2" 25.8 19.7 9.6 208 1 3.5 LG ARNU363BRA4 FC4-8 206 DUCTED 1100 0.2" 28.0 21.7 9.7 208 1 3.6 LG ARNU363BRA4 FC4-9 216 DUCTED 1100 0.2" 25.8 19.7 9.5 1208 1 3 5 Lrr AoKu 119100nn FFC4FC4-10A 286 DUCTED 280 0.2" 9.6 9.2 5.3 208 1 1.06 LG ARNU123BHA4 -10B 282 DUCTED 280 0.2" 9.6 9.2 5.3 208 1 1.06; LG ARNU123BHA4 FC4-11 201 DUCTED 420 0.2" 14.4 11.8 5.5 208 1 1.06; LG ARNU183BHA4 FC5-1 115 DUCTED 650 0.3" 24.0 17.0 27.0 208 1 2.65; LG LHN247HV FC6-1 115 DUCTED 650 0.3" 24.0 17.0 27.0 208 1 2.65 LG LHN247HV FC7-1 115 DUCTED 1200 0.3" 36.0 32.1 36.5 208 1 2.65 LG ARNU363NJA4 GENERAL NOTES KITCHEN HOOD MAKE-UP AIR UNIT MANUFACTURER HEATING ELECTRICAL INPUT OUTPUT TAG & MODEL CFM ESP REMARKS NUMBER TYPE (MBH) (MBH) V PH HP MAU-1 CAPTIVE AIRE A1-D250-150 1550 05" NATURAL GAS. 115 106 208 3 1.5 1, 2, 3 NOTES: 1. PROVIDE INTERLOCK RELAY FOR INTERLOCK WITH KEF-1. 2. PROVIDE 20" HIGH INSULATED CURB. 3. PROVIDE MOTORIZED O.A. DAMPER. EXHAUST FANS TAG MANUFACTURER & MODEL NUMBER TYPE CFM ESP ELECTRICAL REMARKS V PH HP/WATTS KEF-1 COOK VCR-HP165VH6B UPBLAST 1950 1.0" 208 3 3/4 EF-1 COOK GEMINI CEILING 90 0.25" 110 1 30 WATTS EF-2 COOK GEMINI CEILING 90 0.25" 110 1 30 WATTS EF-3 COOK GEMINI CEILING 90 0.25" 110 1 30 WATTS EF-4 COOK ACED12OC100 DOWNBLAST 900 0.3" 115 1 1/6 EF-5 COOK GEMINI CEILING 90 0.25" 110 1 30 WATTS EF-6 COOK ACED100C15DL DOWNBLAST 450 0.3" 110 1 1/8 EF-7 OOK ACED100C15DM DOWNBLAST 600 0.3" 1 110 1 1 1/8 AIR CONDITIONING UNIT SCHEDULE EXHAUST COOLING HEATING BHP CFM TSP BHP TYPE TOTAL COOLING SENSIBLE COOLING EAT LAT TYPE IN OUT DB OF WB OF DB OF WB OF 4.97 2000 1.34 0.62 DX 178.3 132.5 76.2 64.2 53.3 52.7 NATURAL GAS 150 120 4.97 2000 1.34 0.62 DX 178.3 132.5 76.2 64.2 53.3 52.7 NATURAL GAS 150 120 2.98 1500 1.04 0.37 DX 79.6 59.9 77.0 64.5 54.3 53.3 NATURAL GAS 75 60 4.82 1750 1.24 0.51 DX 177.7 132.4 76.0 1 64.0 53.1 1 52.5 NATURAL GAS 150 120 SUPPLY EXHAUST COOLING TAG LOCATION TSP TOTAL SENSIBLE EAT CFM (IN H2O) HP CFM TSP HP TYPE (MBH) (MBH) DB OF WB OF DOAS-1 LOWER ROOF 5400 3.93" 7.5 5000 3.10 (2)@3 DX 341.6 184.3 80.0 69.6 DOAS-2 LOWER ROOF 4800 5.34" 7.5 4400 4.06 5 DX 289.8 156.1 79.8 69.6 DOAS-3 UPPER ROOF 6000 4.57" 7.5 5400 3.30 7.5 DX 360.3 196.6 80.2 69.6 NOTES: 1. PROVIDE MERV 8 PREFILTER AND MERV 15 FILTER ON OUTSIDE AIR. 2. PROVIDE MERV 8 FILTER ON EXHAUST AIR. 3. ALL FAN MOTORS TO BE PREMIUM EFFICIENCY. 4. UNITS TO BE CONFIGURED FOR BOTTOM SUPPLY AND RETURN AIR CONNECTIONS. S. UNIT TO BE WIRED FOR SINGLE ELECTRICAL CONNECTION. 6. ENTERING AIR TEMPERATURES FOR THE HEATING FURNACE AND DX COOLING COIL BASED ON HEAT RECOVERY PERFORMANCE. SEE SCHEDULES. 7. GAS FURNACE TO HAVE MINIMUM OF 10:1 TURNDOWN RATIO. 8. PROVIDE GFCI DUPLEX SERVICE OUTLET. 9. PROVIDE HOT GAS REHEAT TO ALLOW SUPPLY AIR TEMPERATURE TO BE 70-75F DRY BULB & 60F WB IN COOLING MODE. DOAS UNIT SCHEDULE LAT DB OF WB OF 49.0 48.8 50.3 50.1 50.4 60.2 EAT OF 63.6 63.6 60.0 64.7 LAT V OF 84.8 460 84.8 460 83.1 460 85.9 1460 HEATING TYPE MBH EAT LAT V IN OUT OF OF NATURAL GAS 400 320 43.9 98.5 460 NATURAL GAS 350 280 44.7 98.4 460 NATURAL GAS 1 400 1 320 1 42.9 92.1 460 ELECTRICAL PH I MCA I MCOP MANUFACTURER MODEL NO. NOTES 3 44.3 1 50 TRANE HORIZON SIZE D15 1, 2, 4, 5, 6, 7 3 44.3 50 TRANE HORIZON SIZE D15 1, 2, 4, 5, 6, 7 3 29.0 35 TRANE HORIZON SIZE B084 1, 2, 3, 5, 6, 7 3 44.3 50 TRANE HORIZON SIZE D15 1, 2, 3, 5, 6, 7 ELECTRICAL MANUFACTURER NOTES PH MCA MCOP MODELNO. 3 81.6 90 VALENT VPRC-310-30F401-C-1GC 1-9 3 70.3 90 VALENT VPRC-211D-25C-351-C-1DC 1-9 3 91.7 100 VALENT VPRC-310-30C401-C-1DC 1-9 REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pa (860) 436-4336 F. (860) 436-4450 www.rzdesignassociates.com COTr�•s�f� ` NO.252�9' MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL SCHEDULES DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. M5*1 .� REFRIGERANT HEAT RECOVERY UNITS ELECTRICAL MANUFACTURER UNIT # NO OF PARTS & MODEL NUMBER V PH AMPS HR-1-1 3 208 1 0.08 LG PRH022A HR-1-2 4 208 1 0.16 LG PRH042A HR-1-3 4 208 1 0.16 LG PRH042A HR-1-4 4 208 1 0.16 LG PRH042A HR-1-5 4 208 1 0.16 LG PRH042A HR-2-1 4 208 1 0.16 LG PRH042A HR-2-2 4 208 1 0.16 LG PRH042A HR-3-1 4 208 1 0.16 LG PRH042A HR-3-2 3 208 1 0.12 LG PRH032A HR-3-3 3 208 1 0.12 LG PRH032A HR-3-4 2 208 1 0.08 LG PRH022A HR-4-1 3 208 1 0.12 LG PRH032A HR-4-2 4 208 1 0.16 LG PRH042A HR-4-3 3 208 1 0.12 LG PRH032A HR-4-4 2 208 1 0.08 LG PRH022A HR-4-5 3 208 1 0.12 LG PRH032A NOTES: HR-2-3 4 208 1 0.16 LG PRH042A HR-2-4 3 208 1 0.08 LG PRH022A PUMP SCHEDULE SERIES/SIZE FT OF HEAD ELECTRICAL TAG MANUFACTURER TYPE MODEL GPM (TDH) RPM MOTOR HP VOLTS AMPS PHASE REMARKS NUMBER iivLiivE E-901.5AA6 70 90 3450 3.0 230 9.6 3 P-2 B&G INLINE E-901.5AAB 70 90 3450 3.0 230 9.6 3 BP-2 B&G INLINE ecocirc XL B 55-45 26 11.8 1500 z 208 2.0 1 BP-2 B&G INLINE ecocirc XL B 55-45 26 11.8 1500 2 208 2.0 1 GENERAL NOTES/ACCESSORIES: 1. ACCEPTABLE MANUFACTURERS BY: BELL & GOSSETT, ARMSTRONG PUMPS INC., GRUNDFOS &TACO, INC. 2. PROVIDE MAXIMUM IMPELLER DIAMETER FOR NON -OVERLOADING PERFORMANCE FOR SPECIFIED H(1RGFPC�INFR, TR111/l ANr) RAI AN('.F If1APFI I FR AFTFR CVCTEIIA HAS BEEN INSTALLED AND OPERATED. UNIT HEATER SCHEDULE PUMP SCHEDULE SERIES/SIZE FT OF HEAD ELECTRICAL TAG MANUFACTURER TYPE MODEL GPM (TDH) RPM MOTOR HP VOLTS AMPS PHASE REMARKS NUMBER iivLiivE E-901.5AA6 70 90 3450 3.0 230 9.6 3 P-2 B&G INLINE E-901.5AAB 70 90 3450 3.0 230 9.6 3 BP-2 B&G INLINE ecocirc XL B 55-45 26 11.8 1500 z 208 2.0 1 BP-2 B&G INLINE ecocirc XL B 55-45 26 11.8 1500 2 208 2.0 1 GENERAL NOTES/ACCESSORIES: 1. ACCEPTABLE MANUFACTURERS BY: BELL & GOSSETT, ARMSTRONG PUMPS INC., GRUNDFOS &TACO, INC. 2. PROVIDE MAXIMUM IMPELLER DIAMETER FOR NON -OVERLOADING PERFORMANCE FOR SPECIFIED H(1RGFPC�INFR, TR111/l ANr) RAI AN('.F If1APFI I FR AFTFR CVCTEIIA HAS BEEN INSTALLED AND OPERATED. UNIT HEATER SCHEDULE UNIT HEATER SCHEDULE -HOT WATER EWT LWT PIPE MAX FAN ELECTRICAL REMARKS TAG MFR MODEL MOUNTING BTU/h GPM RUNOUT Wpp (°F) (°F) SIZE (IN) (FT) CFM HP VOLTS PHASE UH-1 RITTLING RH-47 CLG. HUNG 11,550 180 160 1.5 3/4" 0.1 565 BOILER SCHEDULE INPUT (MBH) GROSS AHRI FLOW (GPM) WATER OPERATIONAL UNIT NO. MANUFACTURER THERMAL OUTPUT RATING TURN DOWN VOLUME WATER VENT SIZE AIR INTAKE GAS WEIGHT ACCESSORIES/CONTROLS MODEL EFFICIENCY (MBH) (MBH) (GALLONS) CONNECTION CONNECTION (POUNDS) MIN. MAX. MIN. MAX. B-1 LOCHINVAR 40.0 399.9 98.0% 392 341 10:1 10 105 13 2" 4" 4" 1" 542 FTX400 B-2 LOCHINVAR 40.0 399.9 98.0% 392 341 10:1 10 105 13 2" 4" 4" 1" 542 FTX400 GENERAL NOTES REVIEW. REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 O O l v O� H O [-� O w O �wz I� Q O V1 MECHANICAL AND ELECTRICAL ENGINEERING 7s0 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pe (860) 43"336 Fr (860) 436.4450 www.,mdesignassociates,com ®F C OIV � �P NO.2523 �s ! NS , ate MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE MECHANICAL SCHEDULES DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. M5e2 F.L__T i I 1 1 . 1CIN 5115 1 UH-2 RITTLING RH-18 CLG. HUNG 4,880 180 160 1.0 3/4" 0.2 310 30 115 1 UH-3 RITTLING RH-47 CLG. HUNG 11,830 180 160 1.5 3/4" 0.1 565 i5 RADIANT HEATING PANEL ;SCHEDULE TAG MFR MODEL STYLE LENGTH WIDTH BTUH/ILF NUMBER OF TUBES MOUNTING EWT LWT (IN) (IN) TYPE (°F) (°F) RP1 AIRTITE AR-X MODULAR SEE PLANS 24 400 5 T-BAR 180 160 RP2 AIRTITE AR-X MODULAR SEE PLANS 12 290 3 T-BAR 180 160 GENERAL NOTES/ACCESSORIES: 1. SMOOTH FINISH 2. REFER TO PLANS FOR TOTAL LENGTH. 3. PROVIDE CEILING FILLER PANELS TO MATCH GRID SPACING. EXPANSION TANK SCHEDULE MINIMUM TAG MFR MODEL ACCEPTANCE DIAMETER LENGTH SERVES REMARKS (GALLONS) ET-1 AMTROL AX-20 10.9 12 26 GENERAL NOTES/ACCESSORIES: 1. ACCEPTABLE MANUFACTURERS BY: ARMSTRONG PUMPS INC., TACO, INC. 2. VERTICAL EXPANSION TANK. CABINET UNIT HEATER SCHEDULE UNIT NO. MANUFACTURER MODEL NO. HEATING COIL CFM EAT LAT VOLT PH SERVES BTU/h GPM EWT LINT PD CUH-1 RITTLING RFRC-420-02 4320 .6 180 1160 0.1 150 70 96.9 115 1 VEST.194 CUH-2 RITTLING RW-280-06 13,140 1.9 180 160 0.5 450 70 98.8 115 1 N. STAIR CUH-3 RITTLING RW-280-08 14,490 2.2 180 160 0.1 600 70 95.6 115 1 S. STAIR CUH-4 RITTLING RFRC-420-03 8325 1.1 180 160 0.1 300 70 95.6 115 1 VEST. 180 CUH-5 RITTLING RFRC-420-02 3915 .5 180 160 0.1 125 70 98.3 115 1 VEST.187 CUH-6 RITTLING RFRC-420-02 2700 .5 180 160 0.1 125 70 98.3 115 1 VEST.185 CUH-7 RITTLING RW-280-02 2610 .5 180 1i60 0.1 125 70 98.3 115 1 VEST. 189 GENERAL NOTES RADIANT FLOOR SCHEDULE ROOM NUMBER AREA'SQ. FT BTUH/SQ. FT NO. LOOPS TUBE SPACING TUBE LENGTH MANIFOLD FLOW LOOP FLOW P,(TBH) 0' NOTES 104 1764 20 5 12" 600' 3 GPM .35 GPM .25' 1, 2 132 1041 15 3 12" 360' 4 GPM .35 GPM .25' 1, 2 133 1041 15 3 12" 360' 3 GPM .35 GPM .25' 1, 2 134 1041 15 3 12" 360' 3 GPM .35 GPM 25' NOTES: 1. ALL RADIANT HEAT BASED ON CPS 5/8" PEX-C TUBING 2. DESIGN INFO BASED ON COMFORT PRO AQUA HEAT. ALL ALTERNATES MUST SUBMIT DESIGN CALCULATIONS AND SPECIFICATIONS FOR ENGINEERS APPROVAL (in) (in) (in) (in) (hp) (Ibs) (fpm) (cfm) (kW) REVISIONS CONFORMED SET MARCH 22, 2019 TERMINATE VENT WITH WEATHER CAP (TYP.) BOILER PUMP (TYP.) CHECK VALVE (TYPICAL) 4" BOILER COMBUSTION AIR. (TYPICAL) 4" 4 HLI B-1 BP-1 U PAD FOR ALL EQUIPMENT. 5 MECHANICAL ROOM SECTION M6.1 1/4" = 1'-0" I-1 BOILER VENT, UP THROUGH ROOF (TYPICAL) B-2 BOILER (TYP.) COMBUSTION AIR OUTTHROUGH SIDE WALL (TYP.) STRAINER (TYP.) n 3/4" COND., ROUTE TO NEAREST FLOOR DRAIN. AIR SEPARATOR ,—SYSTEM PUMP �! —� AS-1 P-1 iF: �;HWS­0­2 1/2"� TO BUILDING P2 HWR 1 2 1/21 FROM BUILDING I ET-1 4 HEATING HOT WATER SCHEMATIC M6.1 NTS CONNECT TO CW MAIN 1/2" CW MAKE-UP ISOLATION VALVE (TYPICAL) PRESSURE REDUCING VALVE EXPANSION TANK HOUSEKEEPING PAD (TYP. FOR ALL EQPM. ACID NEUTRALIZER Q WATER HEATER COMBUSTION L-5 BOILER COMBUSTION AIR INTAKE. (TYPICAL) ( � M6.1 AIR INTAKES. i UH-1 F _GWH2 G�1"—PRESSUREINDEPENDENT / II B-1 A CONTROL VALVE. (TYPICAL) / WATER HEATER VENT I gp_1 UP THRU ROOF. (TYPICAL) ( BP-2 AS-1 I Elm®® --.1------------------.3/4"HWR-----------_3/4"HWSET-1 cn � 1/2" HWS- ; � T N•1' (V N JJ N LL,l 1/2" CW MAKE-UP - MECHANICAL ROOM ENLARGED PIPING PLAN 1 /n n = 1 r_nn 2 MECHANICAL ROOM ISO1V1ETRIC M6.1 3 BOILER ISOMETRIC _ M6.1 2" HEADER 2" HEADER 4" VENT UP THRU ROOF. (TYPICAL) HWS ISOLATION VALVE (TYPICAL) CHECK VALVE (TYPICAL) Y-STRAINER (TYPICAL) STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pa (860) 4364336 F• (860) 436-4450 www.rzdesignassociates.com C0i'1f�// W •�7t,� r+yi}, 9�� MOSER PILON NELSON nrec Hirec rs 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 5 6 3 - 6 1 6 4 TITLE MECHANICAL PARTIAL PLANS AND ISOMETRICS DATE 11 /2/2018 COPYRIGHT (C Moser Pilon Nelson Architects DWG. NO. M6.1 0 0 z U N .O d z a B — 0 0 N a� .n E Z3 z U O n z O U V OA 4 ZO BB DD FF HH H. KK PP ® RR Tf UU I I I I I I ELECTRICAL LIGHTING FIRST FLOOR - SOUTH 1 /811 = 1'-011 ELECTRICAL LIGHTING NOTE 1. ALL EXIT SIGNS SHALL BE CIRCUITED TO UNSWITCHED LEG OF AREA EMERGENCY LIGHTING CIRCUIT (FROM PANEL EL1 OR EL2.) i �� ELECTRICAL LIGHTING FIRST FLOOR - NORTH 1 /811 = 1'-0" (T PROJECT NORTH WEST KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 1 2/19/19 BID SUPPLEMENT 1 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 Fr (860) 436-4450 www.rzdesignassociates.com 'frame' , RD W. f� �•i., 1�i G NO.252 l 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL LIGHTING FIRST FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO ELI TT K T M U Q OX U R T U X.4 T ELECTRICAL LIGHTING FIRST FLOOR - WEST 1/8" = 1'-0t1 �� �._ Q — 39 — 41 — 46 ELECTRICAL LIGHTING NOTE 1. ALL EXIT SIGNS SHALL BE CIRCUITED TO UNSWITCHED LEG OF AREA EMERGENCY LIGHTING CIRCUIT (FROM PANEL EL1 OR EL2.) KFYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 1 2119/19 BID SUPPLEMENT 1 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 RocKy wu, cT 06O67 P. (860) 436-4336 F. (860) 436-4450 www.rrdesignassociates,com °;;�:v�PRp V✓. C �Ci�i ' N0.25234"w I : MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL LIGHTING FIRST FLOOR PLAN - WEST DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E192 ®� BB DD FF HH f ) KK vl if PP QC RR TT ELECTRICAL LIGHTING NOTE 1. ALL EXIT SIGNS SHALL BE CIRCUITED TO UNSWITCHED LEG OF AREA EMERGENCY LIGHTING CIRCUIT (FROM PANEL EL1 OR EL2.) UO OV ® K Z BB DD FF HH f IEH KK PP Q RR(TT Ti ) i I I I I I I I I I I I I I I I I I I I I I I I I i I I I I I I I ELECTRICAL LIGHTING SECOND FLOOR - SOUTH 1 /8" = 1'-0" I I I I I I I I I I i ELECTRICAL LIGHTING SECOND FLOOR - NORTH 1/8" = 1'-0" ID PROJECT NORTH KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF S ® x O \O ��71 o I MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAim STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 F. (860) 436-4450 www .rrdesignassociates.com W' co : ' NO.252 O .l EN s F MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL LIGHTING SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E1.3 — — I \ f` +1 / GEN RAL MUSIC L L ELHCT,MQA,LIT , `CFLAOL r> GY COo ORD A iTM NOTES 1. REFER TO THE TECHNOLOGY "T" SERIES DRAWINGS FOR LOCATIONS OF TELCOM, AUDIOVISUAL, AND SECURITY DEVICES. EC TO PROVIDE BACKBOXES AND CONDUIT AS INDICATED. WIRING AND TERMINATIONS BY OTHERS. 2. WHERE 120V POWER IS INDICATED ON THE "T SERIES OF DRAWINGS, EC TO PROVIDE CONDUIT AND WIRING. COORDINATE LOCATIONS WITH TECHNOLOGY CONTRACTOR. 3. WHERE RECEPTACLES ARE INDICATED ON THE "T" SERIES OF DRAWINGS, EC TO PROVIDE RECEPTACLE, CONDUIT AND WIRING FOR CONNECTION OF TECHNOLOGY EQUIPMENT. AA BB DD FF HH H. KK I I I I ELECTRICAL POWER FIRST FLOOR - SOUTH 1/811= 1'-0" QQ RR TT T�. i I I MAIN OFFI CONFERENCE 101 —p 34 RE6CUE ASSISTANCE PANEL. SE� DETAjL 7/E7.3 I I I I I I 41 I I 3 46 I I I � i ELECTRICAL POWER FIRST FLOOR - NORTH 1 /8" = 1'-011 �1 PROJECT NORTH it KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 1 2/19/19 BID SUPPLEMENT 1 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 �I 0 it I� MECHANICAL AND ZELECTR/CAL 5-TIGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 Fr (860) 436-4450 www.rzdesignassociates.com �. COW, NO.25239 ry s0 s MOSER ?TLON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL POWER FIRST FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. E2*1 Q 0 0 N r a� s E z U N O d z CL I I o PAP �� �o QO Qo Qo Q ,It _ QO ! 8 (� (( (l _ J 0 ) � Backboard ; �I DU o I ( Q� Winch I Q0 Q Q O _3/' 9 (F) 0 ��P1A TO CONTROLI ___ SWIG m 1 I, CT -(CD Q0 Q Q0 G (C 1 QO (1I Q CD (0 QO QO CD QO 10 _ Q e QB n� Qn 0�1 Ill II Q B AR QO 1 (0 Q) ��J l 9 F1) O Q QO backboard I G A' —Minch 117 I FPP1I TQ�CONTR �-SINITC �A3-11fJ U Q Q0 QQ I NQS Q kb �Q Q u kU kU Iku d (0 inch IS C �Q Pip A_ IO(0 QOQ0 Q0 QO Q `J QO QO 1 QO 10 QO (D QO p 0 Ol_J 01_J 4L J �L J J �u o� QO (01ku QO (0 Q QO QO r-Q � TO I ONTRO SWITCH arch I PP1A-38 QO QO 1 (k 10 QO 1-Y - �O " mal 1� r� ti III [I� _ _ � n.. I■I � ICI �,� A �=� -_ — - :�� `� INS �_I �'� �� (ice III III II II _ ; VESTIBULE - - r II■� is �,� ■ ■ [I,+, llll ■ 1111 ■ 141=8 5 ► _ � ��� �_ e WB — i 1 QO QO QO QO QO ED Q 1QO Q QO QO QO QO u QU (7 1 49 QO - (Q( (( (Q(- -� (( WINDOW SHADE CONTROL PANEL, Q Q O QO QO Q Q0 u QO QO Q0 (0 ur' PROVIDED BY DIV.12, INSTALLED \7 Q Q Q Q _ CONOL SW Q Q0 0 QO Q0 �� ��' TO CON RO1 SOHI-C�� ,ye [ Q0 I —�—- —�� PP1A1Aad -4Q Backboard oard o NIDER—� Q�ROLLINGD Winch PP1 33 p G RTAIN (( HWRP2 HWRP1 PP1-31 Q— PIT Q � BACKBOARD CONTRO n - Q Q Q A- rI A SWITCHESBACKBOARD L P. 9 r - K K 17 UH-1 ®® 1 I _ P�1 _ P 1- — --- K - 4er —U�s — — — — — - -B-1 - -- - IT - — — — — — - — • 115 • CUSTODIAL STORAGE OFFICE 0 BP-1 ( I CUH-7 EF-2 I 11 I WINDOW SHADE 17 w PP1-18 PP1-30 1 MECHANICAL PP1-35 P.E. STORAGE CONTROL SWITCH 1 114 BP- • • VESTIBULE HMC FC3-8 GYMNASIUM ALCOVE 17 17 1 E7.1 I L nu B-2 ( ( ash' 17 • ' PP1A29,31 1 _ �P 1 pPP1-321-28tv - i I ppr II �_2 - • I I , . _ TP I FC3 E PP1-21 EL1—FA I- — PP1-26 I\ i —i — - — — I PP1--41 CORRIDOR ®PP1-46,48 ATS EM PP1 -16 FC5-1HR3-2 PP1 47 49 MDP PP1-1 TROL CABLET9 HR3-4 'HMC PH-5(OfIROOF) MP1 -20 11 IIu��PP1 F1 I LI I\ — II I11 MSB yKI HR31LP1 EWC PP12 PFC3-12 UTILITY MAIN GTOILET roj42 CORRIDOR FI 11z PP1A-49METERScr 813 o 11PP1A KITCHEN uj PP1-29 109 _ - PP1 7 2" GRS CONDUIT STUBBED I PP1 -_ _ ' T-1 LVDP PP1A-22 wESTLoasY 42' P1-6 THROUGH ROOF AND CAPED UH-3 ' o GI 'TOILET PP1A-21 (FOR FUTURE PHOTOVOLTAIC) ' OU R EQUIPMENT � - I ORAGE - - _ ® - CONTACTOR K-1 FO NT vs OILET ° KP-13 TRIP CONTROL OF G N SUBPA VI E = 1 7 P1-4 1 1-8 4r' GENERAL STORAGE RVICE CORRID - I FCi I I 111 1so UNDER HOOD COO FOOD SERVIN I E P NI. PP1-25 0 0 EF-3 EQUIPMENT. 30A;'S; PROVIDE FEEDER ` 0 rPANEL KP ° ° FC3-6 G STEM LAB LL HE M BELOW SLAB. 105 a i ELECTRICALLY H ,, I LOSURE. I I I - I I` FC3-9 KP;7 KP-4 - o o PP1-11 Li UH-2 ' VIA 1 - KP-1 54" 54„ I KP-5 ` KP GSI V KITCHEN I G J J FI-0-91 IA - ----- _ \`\ C=1 -- I I —j I I � WINDOW SHADE �, CUH-5 \� FC3-3 AFF K -2 26 8 _ 1 g CONTROL SWITCH -� I {r VESTIBULE P1-19,21,23 L i; CWc KP-2 Q I 187 PDC I O ❑ -- ------ --- ---- - - � I 24" LAIJ \__J [' 4 G PP1-2 KP-3 i VIA K- KP-9 - - FC3-10 _� . IIII i I AA, KP-21 I I I I I G IUI KP 27 L—---KP-15 CUSTODIA E I �PIA-5 11 FOOD M NAGER' P-11 O ICE41 J ROUTE 2#12, 3/4"C FROM ANSUL WINDOW SHADE CONTROL PANEL. - - CONTROL PANEL TO SHUNT TRIP__- _ PROVIDED BY DIV.12, INSTALLED — — — — CIRCI IIT RRFAKFR (KP-13) BY DIV. 26. ELECTRICAL KITCHEN NOTES 1. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL KITCHEN EQUIPMENT CONNNECTION DEVICES WITH FOOD SERVICE DRAWINGS AND KITCHEN EQUIPMENT CONTRACTOR. 2. PROVIDE RECEPTACLES WITH NEMA CONFIGURATION AS INDICATED ON FOOD SERVICE DRAWINGS OR AS INDICATED BY MANUFACTURER. 3. ALL RECEPTACLES INSTALLED IN KITCHEN AREA SHALL BE GFI PROTECTED WHETHER LABELED OR NOT. 4. HOOD EXHAUST FANS TO BE WIRED THROUGH SWITCH PROVIDED INTEGRAL WITH HOOD. HOOD LIGHTS FURNISHED BY HOOD MANUFACTURER AND INSTALLED BY ELECTRICAL CONTRACTOR PER MANUFACTURERS INSTRUCTIONS. 5. SOLENOID IN ELECTRONIC GAS VALVES PROVIDED BY PLUMBING CONTRACTOR TO BE INTERLOCKED WITH ANSUL SYSTEM IN ORDER TO SHUT RESPECTIVE GAS VALVES WHEN THE ANSUL SYSTEM HAS BEEN ACTIVATED. REFER TO PLUMBING DRAWINGS FOR VALVE LOCATION. 6. COIL IN STARTER OF ROOF TOP MAKE UP AIR UNIT TO BE WIRED THROUGH CONTACT IN ANSUL SYSTEM TO DISCONNECT ROOFTOP MAKE UP AIR UNIT UPON ACTIVATION OF ANSUL SYSTEM. 7. REFER TO FOOD SERVICE DRAWINGS FOR ALL INTERCONNECTIONS BETWEEN EQUIPMENT, INCLUDING, BUT NOT LIMITED TO, WALK-IN COOLERS/FREEZERS, COMPRESSORS, HOODS, EXHAUST FANS, MAKE UP AIR UNITS, ANSUL SYSTEM, ETC. 8. ALL WORK SHOWN AS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR ON THE FOOD SERVICE DRAWINGS SHALL BE INCLUDED WHETHER SHOWN ON THIS DRAWING OR NOT. CAREFUL COORDINATION SHALL BE MADE BETWEEN THE FOOD SERVICE DRAWINGS AND ALL TRADES TO INSURE PROPER OPERATION OF ALL EQUIPMENT, INCLUDING HOOD FIRE SUPPRESSION SYSTEM AND THE SEQUENCE OF OPERATION OF SUCH EQUIPMENT. ELECTRICAL POWER FIRST FLOOR - WEST 1/8" = 1'-0" SF F�t GFI 4r' - 4r' I " I I I FC3-4 PDc 42 ,: IS ARTS u,/ 19 KILN RWIYI \ �� II 1s PP1-14 ' I 19 JERTIC L HR3-3 FC3-2 'Af2TITl I — -PP1-15,17,.19 N- I 1 --� P1 12 I PP1-43,45 J ' ion- \ I+ +t GENERAL MUSIC ' FC74 I RIDOR — — — - — — 42 — 23 24 L3Z — — — FI PLATFORM ACCESS 1 26 PP1-10---1�t1 "NOTE PROV)pE,F:XPAJNSION FITTING AT ALL STORAG DUITSG�FtOSSING EXPANSION JOINT ' II 18 � PP1-42,44 MEDIA CENT OFFICE 04 PP1-9 A CENTER RKROOM PRODUCTION LAB 04. 11 HR2-4 ' CORRIDOR II 182 1 34 I MEDIA CENTER 104 - - I I I — 46 KEYPLAN ELECTRICAL/TECHNOLOGY COORDINATION NOTES 1. REFER TO THE TECHNOLOGY "T" SERIES DRAWINGS FOR LOCATIONS OF TELCOM, AUDIONISUAL, AND SECURITY DEVICES. EC TO PROVIDE BACKBOXES AND CONDUIT AS INDICATED. WIRING AND TERMINATIONS BY OTHERS. 2. WHERE 120V POWER IS INDICATED ON THE "T' SERIES OF DRAWINGS, EC TO PROVIDE CONDUIT AND WIRING. COORDINATE LOCATIONS WITH TECHNOLOGY CONTRACTOR. 3. WHERE RECEPTACLES ARE INDICATED ON THE "T" SERIES OF DRAWINGS, EC TO PROVIDE RECEPTACLE, CONDUIT AND WIRING FOR CONNECTION OF TECHNOLOGY EQUIPMENT. REVISIONS CONFORMED SET MARCH 22, 2019 1 2119/19 BID SUPPLEMENT 1 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENG/NEER/NG 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT06O67 P. (860) 436-4336 F. (860) 436-4450 www.izdesignassociaEes,com e NO.25239 , MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL POWER FIRST FLOOR PLAN - WEST DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E2.2 r^. � n " =rf n /r;% r\ n r\ n ?@, T C C� O UM1l c�UUu G Uuu�1 � u uunl nju I ca 1. REFER TO THE TECHNOLOGY "T" SERIES DRAWINGS FOR LOCATIONS OF TELCOM, AUDIOVISUAL, AND SECURITY DEVICES, EC TO PROVIDE BACKBOXES AND CONDUIT AS INDICATED. WIRING AND TERMINATIONS BY OTHERS. 2. WHERE 120V POWER IS INDICATED ON THE "T' SERIES OF DRAWINGS, EC TO PROVIDE CONDUIT AND WIRING. COORDINATE LOCATIONS WITH TECHNOLOGY CONTRACTOR. 3. WHERE RECEPTACLES ARE INDICATED ON THE "T" SERIES OF DRAWINGS, EC TO PROVIDE RECEPTACLE, CONDUIT AND WIRING FOR CONNECTION OF TECHNOLOGY EQUIPMENT. X 4 �Z AA BB DD FF HH IIEHJ1 KK PP Q RR TT TT I I I I I I I I I I I I I I -_- i 1 1 , ,1 1 1 III 1 I I II 11 JAL 11 ELECTRICAL POWER SECOND FLOOR - SOUTH —�-� 2_4 26 I I I I 39 I I I I I 41 I I — —I - 46 I I I I l I I 1 ELECTRICAL POWER SECOND FLOOR - NORTH E2.3 1/81 1 = 1'-0 rr 1 J 0 1 KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIM STREET SUITE 202 ROCKY HILL, CT 06067 P. (860) 436-4336 F. (860) 4364450 www.rzdesiggnassociates.com - 111111IM111 - AAOSER PTLON NF,LSrI,-.-'N ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL POWER SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. 1 /Orr = 1 r-0" i E2.3 ,4� UU U �� K J �! �� �� U �� �X.4 U ,�A' BB QD HH H. KK PP Q ERR TT T. UU i 3 - 4 KEYPLAN U0 Eel REVISIONS CONFORMED SET JMARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, cT 06067 P. (860) 436-4336 F. (860) 436-4450 www.rzdesignassociates.com MOSER °ICON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL ROOF POWER PLAN DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 1 ELECTRICAL ROOF E2.4 3/32" = F-0" T-T'2 , L141d ELECT RICAUTECHNOLOGY COORDINATION NOTES 1. REFER TO THE TECHNOLOGY "T" SERIES DRAWINGS FOR LOCATIONS OF TELCOM, AUDIOVISUAL, AND SECURITY DEVICES. EC TO PROVIDE BACKBOXES AND CONDUIT AS INDICATED. WIRING AND TERMINATIONS BY OTHERS. 2. WHERE 120V POWER IS INDICATED ON THE "T' SERIES OF DRAWINGS, EC TO PROVIDE CONDUIT AND WIRING. COORDINATE LOCATIONS WITH TECHNOLOGY CONTRACTOR. 3. WHERE RECEPTACLES ARE INDICATED ON THE "T" SERIES OF DRAWINGS, EC TO PROVIDE RECEPTACLE, CONDUIT AND WIRING FOR CONNECTION OF TECHNOLOGY EQUIPMENT. U v X .4 Z AA BB DD FF HH II�H KK I I I I I I I I I I I I I WP ELECTRICAL LOW VOLTAGE FIRST FLOOR - SOUTH 1/811 = 11-011 I I — 15 16 I 4 WP WP 'v AA BB DD FF HH H. KK PP CR I R D3 SAI SAI D3 D IDO I sc cP I C SA I I I I A0 0 lu .41 I I I I WS I I I I Iw • I � I i 1 I Sws 1 I I KINDERGARTEN ■ I KINDERGARTEN ■ SAI ■ 132 I ■I I IFl-33-1 co TOILET % TOILET 0 32 - !;�jl= IL Ii I— I❑ — 771 WP S Q RR TT UU WP TT I WP KINDERG4ARTENIAAI � I I ■ 7IBULE I COR9DOR I I i I i I S I S 27 NO TH STAIR I I 1 I IC J. � , I _ICI ''1 0 S D J ■ - I I I sws I I O I — w�P 0 TOILET TOILET MAI i I I I I I I II I ILoa] E , , i,4- — A R. I ! I I jWAP I ILl DI I I I rN GRADES 1-2 to S GRADES 1-2 CLASSROOM O CLASSROOM 131 I 0 I I O-► K� ^ I I SAI 10I I I 5CP-S SWS 44" ■ ■, — SwS PDC,_'_' 0-SC o o I E sws 1031I SwS I I I OILET TOILET n ® 1736 I I I I I I I I I I 11 Ll I I I � I ;^,SAP WA I 0 I Ll GRADES 1-2 GRADES 1-2 CLASSROOM CLASSROOM -93 1130 136 O-I t-Q sa A SWS PAC L' � e SWS PDC 0 ■ OO ■ kG- SWS ■ ■ F1 PDC SWS LQJ 1;4SAI I I S �}' I 3 I I I D3 I I I I _ _ — GRADES 1-2 — — GRADES 1-2 — — — —� CLASSROOM CLASSROOM 129 1 7 I ITO L L I l i t I I I A W I WAP WP I I I I I I I I I I � O I I. I ■ ■ I � I WP v OILET TOILET SWS I® ■ ® SWS .� -t — I— — — 10 AA ■ — -= Pie sw — — 11 01 MATH INT ENTION I q S t !' SAI IL ��� GRADES 1-2 D3 CLASSROOM 11381I I I I I D3 O SAI S /� O I � SCP SAO i SWS I �PDf1 +� � o i I I I I �SCPSAO PDC SWS I wAp spd D3 I i H LEARNERS I I T7 I I I C i AP I I I I I I I I I 12 I I I I I 14 To® , SOUTH STAIR SwS 1 1�, as I CORK®R LP�j I I I I I I I I I I I 1 ELECTRICAL LOW VOLTAGE FIRST FLOOR - NORTH E3.1 1 /811 = 11-011 111 M.E. 111illimmLa WE -I KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06057 P. (860) 4364336 Fr (860) 436-4450 www.rzdesignassociates.com .ci'.1i1eliil(Y i�pif( co NO 5239 ; MOSER PILON NELSON ARCH I T E C T S 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL LOW VOLTAGE FIRST FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. El� ® E F G TT UK L 77 T I i Ii �I WP I WP ...... ......Wpz-A —I— -—, —I_ ——— — _ —� —m�wmm A + S +96•— w SAI D3 D2 —u WP Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Esc i ( o I ,� n �r—� nn nn nn pr 0 I nr—1 0 fr er I (f�1 IOr 1 0�1 (l 0 1 ��1 H I ISA e �9� ELECTRICAL LOW VOLTAGE FIRST FLOOR - WEST 1/811 = 1'-0" 0 0 N L a� E z U N O n- z n n tY i I I I J 29 - 41 — 46 ELECT RICAUTECHNOLOGY COORDINATION NOTES 1. REFER TO THE TECHNOLOGY "T' SERIES DRAWINGS FOR LOCATIONS OF TELCOM, AUDIOVISUAL, AND SECURITY DEVICES. EC TO PROVIDE BACKBOXES AND CONDUIT AS INDICATED. WIRING AND TERMINATIONS BY OTHERS. 2. WHERE 120V POWER IS INDICATED ON THE "T' SERIES OF DRAWINGS, EC TO PROVIDE CONDUIT AND WIRING. COORDINATE LOCATIONS WITH TECHNOLOGY CONTRACTOR. 3. WHERE RECEPTACLES ARE INDICATED ON THE "T" SERIES OF DRAWINGS, EC TO PROVIDE RECEPTACLE, CONDUIT AND WIRING FOR CONNECTION OF TECHNOLOGY EQUIPMENT. KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUME 202 ROCKYH/LL, cT06067 P. (860) 436-4336 F. (860) 436-4450 www,rzdesignassociates.com fEls�f. N0.2523�9(' *� � MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 563-6164 TITLE ELECTRICAL LOW VOLTAGE FIRST FLOOR PLAN - WEST DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E392 10 d 0 0 N L a) .0 E z U N O A z d ELECTRICALITECHNOLOGY COORDINATION NOTES 1. REFER TO THE TECHNOLOGY "T" SERIES DRAWINGS FOR LOCATIONS OF TELCOM, AUDIONISUAL, AND SECURITY DEVICES. EC TO PROVIDE BACKBOXES AND CONDUIT AS INDICATED. WIRING AND TERMINATIONS BY OTHERS. 2. WHERE 120V POWER IS INDICATED ON THE'7 SERIES OF DRAWINGS, EC TO PROVIDE CONDUIT AND WIRING. COORDINATE LOCATIONS WITH TECHNOLOGY CONTRACTOR. 3. WHERE RECEPTACLES ARE INDICATED ON THE "T" SERIES OF DRAWINGS, EC TO PROVIDE RECEPTACLE, CONDUIT AND WIRING FOR CONNECTION OF TECHNOLOGY EQUIPMENT. U V U X.4 AA BB DD FF HH H. KK PP Q RR TT T UU ELECTRICAL LOW VOLTAGE SECOND FLOOR - SOUTH 1 /8" = 1'-0" I I i I I I I I I 41 I I I 46 I I I n AA A�. BB DD FF HH H. KK I 1V� PP I, I I I I I ELECTRICAL LOW VOLTAGE SECOND FLOOR - NORTH 1 /8" = 1'-0" QQ C O KEYPLAN REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 RocKYHILL, cT06067 Pc (860) 436-4336 Fr (860) 436-4450 www.rzdesignassociates.com s� r� NO. 2 23 k; MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL LOW VOLTAGE SECOND FLOOR PLAN - NORTH AND SOUTH DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E3*3 5 Z, REVISIONS CONFORMED SET MARCH 22, 2019 Q ®� BB DD FF HH II�H� KK 0 0 N L a) I_ z t. a) 0 ^L LL z n pp Q RR TT I UU I i 42" f� STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 NECHAN/CAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pe (860) 436-4336 F. (860) 436-4450 vi ww.mdesignassvciates.com �-o�, N0. 31f �• MOSER l PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 5 6 3 - 6 1 6 4 TITLE ALTERNATE 1 - ADDED CLASSROOMS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. FLOOR - ALTERNATE 1 E4el REVISIONS CONFORMED SET MARCH 22, 2019 LIGHTING FIXTURE SCHEDULE ALTERNATE 1 ALTERNATE 2 I LAMPS MANUFACTUR ER MODEL MANUFACTURER MODEL TYPE MANUFACTURER MODEL VOLTAGE REMARKS --- LUMENS WATTAGE LUMENS/WATTI Pendant Linear Direct/Indirect - Row lengths per plans (Lamp data per 4' section) 2x2 LED Basket Troffer 2x2 LED Basket Troffer - Connect to Emergency Lighting Panel Pendend Directlindirect LED Lighting Fixture Cloud Pendant Direct/Indirect LED Circle Recessed LED Linear - Length per plans (Lamp_ data per foot) Single Face Exit Sign w/Accessibility Symbol Double Face Exit Sign w/Accessibility Symbol FINELITE DAYBRITE DAYBRITE EUREKA VOIGT LEDALITE EVENLITE EVENLITE S16LEDOIDODCO-XX-V-8350OPEN-277-SC-FA50-FE-C1 2EVG-38L-835-2-D-UNV-DIM 2EVG-38L-835-2-D-UNV-DIM 4800-24-LED-277-DV RDP-AC-WHM-WHM ZO-6040-55OL-835/90CRI-DI-OP-AC48"-WH-277-DIM 3908-L-B-X-Q-S-1-XX-7-277-E TLAACR1 W TLAACR2W COREELITE METALUX METALUX SONNEMAN CAMMAN NEORAY SUKt:L1 T E:S SUREELITES J3-UL-40L835-1 D-UNV-STD-XX-W-AC48-XX-XX 22CZ-LD5-39-UNV-L835-CD1-U 22CZ-LD5-39-UNV-L835-CD1-U 1730.16 P1044-60-LN-35,-CLV-2-WM-PMW-AC S123DR-S-34OD-835 UAW VV1`1/t.7%0LVVr1K/ CX62WH/CX62WHR7 CX61 WH A Alera Lighting _ LP7-OA-ROW-35LW-20-CM48-EDU-MW 4200 Im 37 W 114 Im/W 277 V B BE Columbia Lighting Columbia Lighting Modern Forms LCAT22-35-HLG-EDU LCAT22-35-HLG-EDU PD-90830 3707 Irn 3707 Im 1234 Im 32 W 32 W 29 W 116 Im/W 116 Im/W 42 Im/W 277 V 277 V 277 V C C1E Axis Lighting SKPE10005SL60/40CIR5508035SOWUNV RMRI Fn4nnRn35FL-Lenath-W-UNV 6912 Im 400 Im 74 W 4 W 94 Im/W 108 ImAN 277 V 277 V n Avic Light EX1 EX2 Compass Compass CSAUDR CSAUDR 5 W 5 W 277 V 277 V EX3 Compass CSAUER 5 W 277 V Single Face Exit Sign Double Face Exit Sign Recessed LED Linear- Length per plans (Lamp data per foot) Recessed LED Linear - Length per plans - Connect to Emergency Lighting Panel (Lamp data per foot) Recessed LED Linear 8'x6' Rectangle Pattern - Connect to Emergency Lighting Panel Recessed LED Linear 8'x8' Square Pattern - Connect to Emergency Lighting Panel LED lensed striplight I .-.-. .. _ - _ _ _. _,,_�:_�, LED lensed striplight LED lensed striplight Decorative LED Highbay Decorative LED Highbay - Connect to Emergency Lighting Panel 4" LED Open Downlight 4" LED Open Downlight - Connect to Emergency Lighting Panel 2x2 LED Lensed/Gasketed Troffer Recessed LED Linear - Length per plans (Lamp data per foot) Recessed LED Linear - Length per plans - Connect to Emergency Lighting Panel (Lamp data per foot) LED Bi-Level Strip with Control - Connect to Emergency Lighting Panel Exterior LED Wall Pack EVENLITE EVENLITE LEDALITE LEDALITE LEDALITE LEDALITE DAYBRITE I A nVRRI- • - DAYBRITE DAYBRITE DAYBRITE DAYBRITE H.E. WILLIAMS H.E. WILLIAMS DAYBRITE FINELITE FINELITE DAYBRITE GARDCO TLA6ACR1 W TLA6ACR2W 2301-L-B-G-Q-S-T-XX-7-277-E 2301-L-B-G-Q-S-T-XX-7-277-E 2301-L-B-G-Q-S-T-XX-7-277-E-90 2301-L-B-G-Q-S-T-XX-7-277-E-90 FSW-4-55L-835-UNV-DIM - • - - --- --- - - FSW-8-55L-835-UNV-DIM FSW-4-55L-835-UNV-DIM RBX-20L-835-UNV-WT-ARR22-22CL RBX-20L-835-UNV-WT-ARR22-22CL 4DRTL-L20-835-DIM-UNV-0-M-OF-SG-MWT 4DRTL-L20-835-DIM-UNV-0-M-OF-SG-MWT 2TG-30L-835-2-FA19F-UNV-DIM-3W HP4R-XX-B-835-F-277-SC-C1 HP4R-XX-B-835-F-277-SC-C1 FSS-4-55L-835-UNV-SDIM-LSXR10ADC 121-16L-1000-WW-G3-3-UNV-BK SUREELITES SUREELITES GAMMALUX GAMPOALUX GAMMALUX GAMMALUX METALUX METALUX METALUX ATLANTIC ATLANTIC ALPHABET ALPHABET METALUX ALW ALW METALUX McGRAW-EDISON CX62WH GB1 3RC2-1 SL358-277-4'-N-REC/XXX-ASLMD-W-XX GB13RC2-1 SL358-277-4'-N-REC/XXX-ASLMD-W-XX GB13RC2-1 SL358-277-4'-N-REC0=-ASLMD-W-XX GB13RC2-1SL358-277-4'-N-REC/XXX-ASLMD-W-XX 4SNLED-LD5-65SL-SLW-UNV-L835-CD1-U 8TSNLED-LD5-65SL-SLW-UNV-L835-CD1-U 4SNLED-LD5-65SL-SLW-UNV-L835-CD1-U LHB22-C7200-35K-WH-P18-22PRA LHB22-CZ200-35K-WH-PI8-22PRA NU6-RD-XTM19-30LM-35K-83-HE40-277-DIM1 O-WH-WH NU6-RD-XTM19-30LM-35K-83-HE40-277-DIM10-WH-WH 22GR-LD5-32-F1-UNV-L835-CD1-U-G3 SP4R-F-SXX-LOW-80-35K-CR/S-N-WH-UNV SP4R-F-SXX-LOW-80-35K-CR/S-N-WH-UNV 4SRL-LD5-50SL-LW-UNV-L835-CD1-U GWC-AF-02-LED-E1-T3-BK EX4 F Compass Axis Lighting Axis Lighting CSAUER SCR5008035FLS#WUNV SCR5008035FLS#WUNV 500 Im 500 Im 5 W 6 W 6 W 90 Im/W 90 Im/W 90 Im/W 90 Im/W 277 V 277 V 277 V 277 V 277 V FIE FIRE FSE Axis Lighting Axis Lighting SCR5008035FLS#WUNVDF SCR5008035FLS#WUNV 14000 Im 16000 Im 155 W 178 W G Columbia Lighting LCL4-35-HL-EU 6395 Im 52 W 123 Im/W 277 V - -_ - _ - _ .. _ - . _ _ . _ - . ___ .. G1E Columbia Lighting LCL8-35-HL-EU 12790 Im 104 W 123 Im/W 277 V GE Columbia Lighting LCL4-35-HL-EU 6395 Im 52 W 123 Im/W 277 V H HE J JE Hubbell Industrial Lighting Hubbell Industrial Lighting Pathway Lighting Pathway Lighting LBX2-HO-U-35K-A2-CDI-WH-WA22 LBX2-HO-U-35K-A2-CD1-WH-WA22 4LB79V3035KE2M40D8/4PLEDSCLPF 4LB79V3035KE2M40D8/4PLEDSCLPF 21985 Im 21985 Im 2331 Im 2331 Im 202 W 202 W 27 W 27 W 109 Im/W 109 Imm 86 Im/W 86 Im/W 83 Im/W 111 Im/W 111 Im/W 121 Im/W 120 V 120 V 277 V 277 V 277 V 277 V 277 V 277 V K Columbia Lighting LLT22-25HLG-FS-Al9F-G3 3300 Im 400 Im 400 Im 5087 Im 40 W 4 W 4 W 42 W M ME NE Axis Lighting Axis Lighting Columbia Lighting BBRLED4008035FLS#WUNV BBRLED4008035FLS#WUNV LBIL4-35ML-EU OAE Spaulding Lighting LMC-30L4-3K-3-035-2 33137K3BLK LNC2-12L-3K-035-3-U-BL VWGL-1 C4X24AC-P4545-02-30WH-6' C95AV3035WDAMW1 C95AV3035WDAMW1 3972 Im 39 W 102 Im/W 277 V Round LED Ceiling Lighting - Wet Location Exterior LED Wall Pack Elevator Hoistway Light Exterior LED Linear. Provide w/remote transformer, adjustable mounting hardware and connecting cables. Pendant LED Cylinder Pendant LED Cylinder - Connect to Emergency Lighting Panel Decorative Pendant LED Cylinder LED Pendant Chandelier MUNALL H.E. WILLIAMS STONCO SSL H.E. WILLIAMS H.E. WILLIAMS BORDEN INTERLUX IyIR13FFL_PP_IVIB_10L351: VWMV-L10/830-TL-BLK-UNV VWXL-I4-NW-GI-8 ECVLWET-250-1-277-3K-ADBW2-SC10W-TCAPW-6' LENGTH LC7-L40C/835-WHT-CS/W-CWXX-DIM LC7-L40C/835-WHT-CSM-CWXX-DIM 345-LED/14-277/SAL-STEM 11 52.12.05.70.OT/01. 12.60.30.360000 PH LUMARK PHOENIX i2 SYSTEMS ATLANTIC ATLANTIC BRUCK SONNNEMAN 071441 XTOR1B-Y-BK VA-W-17LED-CW-FGC V3285A-363CBB-OD-BA-VLA14-6' LENGTH CLED614-B60-VR35-35K-WH-WH CLED614-B60-VR35-35K-WH-WH 223-805-MC-MP 2766.16 OBE Bega Lighting Spaulding Lighting Hubbell Industrial Lighting Tempo Lighting Pathway Lighting Pathway Lighting 1175 Im 1433 Im 757 Im 2028 Im 3165 Im 3165 Im 450 Im 18 W 14 W 11 W 15 W 24 W 24 W 6 W 80 W 651m/W 102 Im/W 69 Im/W 135 Im/W 133 Im/W 1331m/W 82 Im/W 62 Im/W 277 V 277 V 120 V 277 V 277 V 277 V 277 V 277 V OC OD OFE P PE Q Pathway Lighting P8WWL435KC3WW R Modem Forms PD-64875 4960 Im R1 E Modem Forms PD-64849 n� 0AQ'7r_ r v-vtu, a VPS-36NB-80-3K-T2-UNV-RA-BMT VPS-36NB-80-3K-T2-UNV-RA-BMT VPS-36NB-80-3K-T4-UNV-RA-BMT VPS-36NB-80-3K-T4-UNV-BLC-RA-BMT VPS-36NB-80-3K-T5QM-UNV-RA-BMT VPS-36NB-80-3K-T4-UNV-RA-BMT VPS-36NB-80-3K-T4-UNV-RA-BMT 1923 Im A0An Im ....... I- 7224 Im 7224 Im 7868 Im 7868 Im 7868 Im 7868 Im 7868 Im 30 W Rn tn/ 8 .. 80 W 80 W 80 W 80 W 80 W 80 W 80 W 64 Im/W a9 ImAA/ - - 90 Im/W 90 Im/W 98 Im/W 98 Im/W 98 Imm 98 Im/W 98 Im/W 277 V 977 V - 277 V 277 V 277 V 277 V 277 V 277 V 277 V LED Pendant Chandelier - Connect to Emergency Lighting Panel LED Pendant Chandelier - Connect to Emergencv Lighting Panel --- - - - - Pole mount Site Lighting fixture - With 12' Pole #SSS-B-1 2-40-A-1 -B4-BL Pole mount Site Lighting fixture - With 16' Pole #SSS-B-16-40-A-1-B4-BL Pole mount Site Lighting fixture - With 12' Pole #SSS-B-12-40-A-1-B4-BL Pole mount Site Lighting fixture w/Backlight Control- With 12' Pole #SSS-B-1 2-40-A-1 -B4-BL Pole mount Site Lighting fixture - With 12' Pole #SSS-B-12-40-A-1-B4-BL (2) Pole mount Site Lighting fixture (back-to-back)- With 16' Pole #SSS-B-16-40-A-1-B4-BL Pole mount Site Lighting fixture - With 16' Pole #SSS-B-16-40-A-1-64-13L Inground Flood for Flagpole lighting LED Linear Cabinet Light. Provide w/remote driver and interconnecting cables LED Linear Cabinet Light. Provide w/remote driver and interconnecting cables 2' Long Undercabinet LED INTERLUX INTERLUX GARDCO GARDCO GARDCO GARDCO GARDCO GARDCO GARDCO HADCO Q-TRAN Q-TRAN IKENALL 1150.12.05.70.OT/01.12.60.30.250000 1152.12.05.70.OT/01.12.60.30.360000 ECF-S-32L-700-WW-G2-AR-2-277-BK ECF-S-32L-700-WW-G2-AR 2-277-BK ECF-S-32L-700-WW-G2-AR-4-277-BK ECF-S-32L-700-WW-G2-AR-4-277-BK/HIS-32-H ECF-S-32L-700-WW-G2-AR-5W-277-BK ECF-S-32L-700-WW-G2-AR-4-277-BK ECF-S-32L-700-WW-G2-AR-4-277-BK SL43BZWFNNN SW24/4.0-DRY-30-BRL-BRL-84/ARKA-ST-PL-DF-84 SW24/4.0-DRY-30-BRL-BRL-60/ARKA-ST-PL-DF-60 jAUCLEDSMW16L35K24277 SONNNEMAN SONNNEMAN 2766.16 2793.16 KC SA SIB SC SD SF SG SH .._ IVIOdern rdnns Beacon Lighting Beacon Lighting Beacon Lighting Beacon Lighting Beacon Lighting Beacon Lighting Beacon Lighting McGRAW-EDISON McGRAW-EDISON McGRAW-EDISON McGIRAW-EDISON MCGRAW-EDISON McGIRAW-EDISON McGIRAW-EDISON LUMIIERE NOV,AFLEX NOV•AFLEEX FAILSAFE GLEON-AF-02-LED-E1-T2-BK-8030-600 GLEON-AF-02-LED-El-T2-BK-8030-600 - - - GLEON-AF 02-LED E1 T4-BK-8030-600 GLEON-AF-02-LED-El-SL4-BK-8030-600 GLEON-AF-02-LED-E1-5MQ4-BK-8030-600 GLEON-AF-02-LED-El-T4-BK-8030-600 GLEON-AF-02-LED-El-T4-BK-8030-600 3002N-RD-18LED3000-MFL-NSL-UNV-BZ NF-DS-0-128-24V-3000K-84"/NF-CH-3030-84" NF-DS-0-128-24V-3000K-60"/NF-CH-3030-60" UCL-2-LD4-35-89BW-EDD1-UNV SJ T T1 Kim Lighting IMP Lighting IMP Lighting LTV82FFNF18L3KUVSR L102A-7-W30S-W-F-MA L102A-5-W30S-W-F-MA 13LN35K-24-S-3-D10 1558 Im 700 Im 500 Im 1090 Im 22 W 16 W 12 W 9 W 71 Im/W 43 Im/W 43 Im/W 121 IMAN 277 V 277 V 277 V 277 V UC Airey-Thompson NOTE: LIGHT FRTURES SUPPLIED SHALL BE ONE OF THE THREE LISTED MANUFACTURERS. NO SUBSTITUTIONS WILL BE ALLOWED. MOTOR COORDINATION SCHEDULE ID EQUIPMENT INFORMATION CIRCUIT INFORMATION DISCONNECT REMARKS REAL POWER FLA MCA MOCP VOLT PH PANEL NO. APPARENT LOAD LOAD CLASSIFICATION WIRE & CONDUIT SIZE TYPE FURNISH AC-1 30820 W 41.2 A 44.3 A 50 A 480 V 3 MP1 1,3,5 34245 VA HVAC 3#10,#1 OG,3/4"C NFS DIV. 26 Weatherproof Disc AC-2 30820 W 41.2 A 44.3 A 50 A 480 V 3 MP1 2,4,6 34245 VA HVAC 3#10,#1 OG,3/4"C NFS DIV. 26 Weatherproof Disc AC-3 20785 W 25.0 A 29.0 A 35 A 480 V 3 MP1 7,9,ll 20785 VA HVAC 3#10,#1 OG,3/4 C NFS DIV. 26 Weatherproof Disc AC-4 30820 W 41.2 A 44.3 A 50 A 480 V 3 MP1 8,1u,12 34245 VA HVAC 3#o,#1uG,3/4"C NFS DIV. 26 .",!eathe Nroof Disc B-1 1296 W 12.0 A 15.0 A 20 A 120 V 1 PP1 37 1440 VA HVAC 2#12,#12G,3/4"C TOGGLE DIV. 26 B-2 1296 W 12.0 A 15.0 A 20 A 120 V 1 PP1 36 1440 VA HVAC 2#12,#12G,3/4"C TOGGLE DIV. 26 Backboard Winch 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 39 1176 VA Other 2#12,#12G,3/4"C Backboard Winch 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 41 1176 VA Other 2#12,#12G,3/4"C Backboard Winch 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 34 1176 VA Other 2#12,#12G,3/4"C Backboard Winch 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 40 1176 VA Other 2#12,#12G,3/4"C Backboard Winch 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 36 1176 VA Other 2#12,#12G,3/4"C Backboard Winch 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 38 1176 VA Other 2#12,#12G,3/4"C BPA 416 W 2.0 A 2.5 A 15 A 208 V 1 PP1 52,54 416 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 BP-2 416 W 2.0 A 2.5 A 15 A 208 V 1 PP1 52,54 416 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 C-1 12970 W 15.6 A 19.5 A 20 A 480 V 3 MP1 19,21,23 12970 VA HVAC 3#12,#12G,3/4"C CU-1 3228 W 11.2 A 14.0 A 20 A 208 V 3 KP 35,37,39 4035 VA KTCH 3#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc CU-2 1747 W 10.5 A 13.1 A 20 A 208 V 1 KP 20,22 2184 VA KTCH 2#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc CUH-1 38 W 0.4 A 0.4 A 20 A 120 V 1 PP2 9 42 VA HVAC 2#12,#12G,3/4"C CUH-2 136 W 1.1 A 1.4 A 20 A 120 V 1 PP2 6 136 VA HVAC 2#12,#12G,3/4"C CUH-3 208 W 1.7 A 2.2 A 20 A 120 V 1 PP2 30 208 VA HVAC 2#12,#12G,3/4"C CUH-4 38 W 0.4 A 0.4 A 20 A 120 V 1 PP2 25 42 VA HVAC 2#12,#12G,3/4"C CUH-5 38 W 0.4 A 0.4 A 20 A 120 V 1 PP1 25 42 VA HVAC 2#12,#12G,3/4"C CUH-6 38 W 0.4 A 0.4 A 20 A 120 V 1 PP1 13 42 VA HVAC 2#12,#12G,3/4"C CUH-7 27 W 0.3 A 0.3 A 20 A 120 V 1 PP1 23 30 VA HVAC 2#12,#12G,3/4"C DOAS-1 65181 W 78.4 A 81.6 A 90 A 480 V 3 MP1 13,15,17 65181 VA HVAC 3#4,#8G,1"C NFS DIV. 26 Weatherproof Disc DOAS-2 53624 W 64.5 A 70.3 A 90 A 480 V j 3 MP1 14,16,18 53624 VA HVAC 3#4,#8G,1"C NFS DIV. 26 Weatherproof Disc DOAS-3 76238 W 87.5 A 91.7 A 100 A 480 V 3 MP2 1,3,5 76238 VA HVAC 3#3,#BG, 1-1/4"C NFS DIV. 26 Weatherproof Disc EF-1 27 W 0.3 A 0.3 A 15 A 120 V 1 PP2 29 30 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 EF-2 27 W 0.3 A 0.3 A 15 A 120 V 1 PP1 23 30 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 EF-3 27 W 0.3 A 0.3 A 15 A 120 V 1 PP1 29 30 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 EF-4 528 W 4.4 A 5.5 A 15 A 120 V 1 PP1A 42 528 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc EF-5 27 W 0.3 A 0.3 A 15 A 120 V 1 PP3 35 30 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 EF-6 420 W 3.5 A 4.4 A 15 A 120 V 1 PP1A 44 420 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc EF-7 420 W 3.5 A 4.4 A 15 A 120 V 1 PP3 32 420 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc FC1-1 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 13,15 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-2 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 13,15 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-3 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 13,15 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-4 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 5,7 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-5 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 17,19 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-6 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 5,7 728 VA HVAC 2#12,#12G,3X'C NFS DIV. 26 FC1-7 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 17,19 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-8 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 5,7 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-9A 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 5,7 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-9B 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 10,12 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-10 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 17,19 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-11 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 10,12 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-12 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 10,12 220 VA HVAC 2#12,#12G,3/4"C NFS DIV, 26 FC1-13 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 10,12 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-14 496 W 2.7 A 3.3 A 15 A 208 V 1 PP3 1 10,12 551 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-15 187 W 1.0 A 1.3 A 15 A 208 V 1 PP3 10,12 208 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-16 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 I 10,12 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC1-17 496 W 2.7 A 3.3 A 15 A 208 V 1 PP3 17,19 551 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-1 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 2,4 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-2 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 2,4 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-3 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 2,4 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-4 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 2,4 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-5 496 W 2.7 A 3.3 A 15 A 208 V 1 PP3 2,4 551 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-6 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 1,3 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-7 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 1,3 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-8 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 1,3 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-9 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 1,3 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-10 198 W 1.1 A 1.3 A 15A_ 208 V 1 PP3 1,3 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC2-11A 655 W 3.5 A 4.4 A 15 A 208 V 1 PP1 42,44 728 VA HVAC 2#12,#12G,34'C NFS DIV. 26 0 0 (V L aD E z U N O 0- z CL MOTOR COORDINATION SCHEDULE EQUIPMENT INFORMATION CIRCUIT INFORMATION DISCONNECT ID REAL POWER FLA MCA I MOCP VOLT PH PANEL NO. APPARENT LOAD LOAD CLASSIFICATION WIRE' & CONDUIT SIZE TYPE FURNISH REMARKS FC2-11 B 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 2,4 728 VA HVAC 2#12'.,#12G,3/4"C NFS DIV. 26 FC2-12 37 W 0.2 A 0.3 A 15 A 208 V 1 PP1 42,44 42 VA HVAC 2#12'.,#12G,3/4"C NFS DIV. 26 FC2-13 198 W 1.1 A 1.3 A 15 A 208 V 1 PP1 42,44 220 VA HVAC 2#12',#12G,3/4"C NFS DIV. 26 FC2-14 37 W 0.2 A 0.3 A 15 A 208 V 1 PP3 2,4 42 VA HVAC 2#12',#12G,3/4"C NFS DIV. 26 FC2-15 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 2,4 220 VA HVAC 2#12',#12G,3/4"C NFS DIV. 26 FC3-1 655 W 3.5 A 4.4 A 15 A 208 V 1 PP1 43,45 728 VA HVAC 2#12!,#12G,3/4"C NFS DIV. 26 FC3-2 655 W 3.5 A 4.4 A 15 A 208 V 1 PP1 43,45 728 VA HVAC 2#12!,#12G,3/4"C NFS DIV. 26 FC3-3 973 W 5.2 A 6.5 A 15 A 208 V 1 PP1 47,49 1082 VA HVAC 2#12!,#12G,3/4"C NFS DIV. 26 FC3-4 198 W 1.1 A 1.3 A 15 A 208 V 1 PP1 43,45 220 VA HVAC 2#121.,#12G,3/4"C NFS DIV. 26 FC3-5 37 W 0.2 A 0.3 A 15 A 208 V 1 PP1 47,49 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-6 198 W 1.1 A 1.3 A 15 A 208 V 1 PP1 47,49 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-7 198 W 1.1 A 1.3 A 15 A 208 V 1 FIN 46,48 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-8 37 W 0.2 A 0.3 A 15 A 208 V 1 PP1 46,48 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-9 37 W 0.2 A 0.3 A 15 A 208 V 1 PP1 46,48 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-10 37 W 0.2 A 0.3 A 15 A 208 V 1 PP1 46,48 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-111 37 W 0.2 A 0.3 A 15 A 208 V 1 PP1 46,48 42 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC3-12 198 W 1.1 A 1.3 A 15 A 208 V 1 PP1 47,49 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-1 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 14,16 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-2 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 9,11 728 VA HVAC 2#12?,#12G,3/4'C NFS DIV. 26 FC4-3 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 6,8 728 VA HVAC 2#12?,#12G,3/4"C NFS DIV. 26 FC4-4 655 W 3.5 A 4.4 A 15 A 208 V 1 1 PP3 9,11 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-5 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 6,8 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-6 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 9,11 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-7 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 6,8 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-8 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 14,16 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-9 655 W 3.5 A 4.4 A 15 A 208 V 1 PP3 14,16 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-1 OA 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 6,8 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-1 OB 159 W 0.8 A 1.1 A 15 A 208 V 1 PP3 21,23 176 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC4-11 198 W 1.1 A 1.3 A 15 A 208 V 1 PP3 21,23 220 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 FC5-1 216 W 0.6 A 0.8 A 15 A 208 V 2 216 VA HVAC CONTROL CABLE Control Cable by MFGR FC6-1 216 W 0.6 A 0.8 A 15 A 208 V 2 216 VA HVAC CONTROL CABLE Control Cable by MFGR FC7-1 233 W 1.1 A 1.4 A 15 A 208 V 1 PP1 43,45 233 VA MTR 2#12,#12G,3/4"C GWH1 540 W 5.0 A 6.3 A 15 A 120 V 1 PP1 50 600 VA HVAC 2#12,#12G,3/4"C TOGGLE DIV. 26 GWH2 540 W 5.0 A 6.3 A 15 A 120 V 1 PP1 50 600 VA HVAC 2#1;2,#12G,3/4"C TOGGLE DIV. 26 HP-1 21283 W 32.0 A 35.7 A 50 A 480 V 3 MP2 2,4,6 26604 VA HVAC 3#8,#10G,3/4"C NFS DIV. 26 Weatherproof Disc HP-1 (A) HP-2 22880 W 22880 W 34.4 A 34.4 A 38.3 A 38.3 A 50 A 50 A 480 V 480 V 3 3 MP2 MP2 8,10,12 7,9,11 28600 VA 28600 VA HVAC HVAC 3#8,#10G,3/4"C 3#8,#10G,3/4"C NFS NFS DIV. 26 DIV. 26 Weatherproof Disc Weatherproof Disc HP-3 21283 W 32.0 A 35.7 A 50 A 480 V 3 MP1 20,22,24 26604 VA HVAC 3#E;,#10G,3/4"C NFS DIV. 26 Weatherproof Disc HP-4 10442 W 15.7 A 18.4 A 25 A 480 V 3 MP2 13,15,17 13053 VA HVAC 3#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc HP-4 (A) HP-4 (6) HP-5 15830 W 22880 W 3141 W 23.8 A 34.4 A 15.1 A 26.0 A 38.3 A 18.9 A 35 A 50 A 30 A 480 V 480 V 208 V 3 3 1 MP2 MP2 PP1A 14,16,18 20,22,241 25,27 19787 VA 28600 VA 3141 VA HVAC HVAC HVAC 3#110,#10G,3/4"C 3#12,#12G,3/4"C 2#12,#12G,3/4"C NFS NFS NFS DIV. 26 DIV. 26 DIV. 26 Weatherproof Disc Weatherproof Disc Weatherproof Disc HP-6 3141 W 15.1 A 18.9 A 30 A 208 V 1 PP3 25,27 3141 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc HP-7 4264 W 20.5 A 25.6 A 40 A 208 V 1 PP1A 46,48 4264 VA HVAC 2#10,#10G,3/4"C NFS DIV. 26 Weatherproof Disc HR1-1 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 5,7 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR1-2 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 17,19 1 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR1-3 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 10,12 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR1-4 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 5,7 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR1-5 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 10,12 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR2-1 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 2,4 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR2-2 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 2,4 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR2-3 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 2,4 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR2-4 30 W 0.2 A 0.2 A 15 A 208 V 1 PP1 42,44 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR3-1 30 W 0.2 A 0.2 A 15 A 208 V 1 PP1 47,49 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR3-2 30 W 0.2 A 0.2 A 15 A 208 V 1 PP1 46,48 1 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR3-3 30 W 0.2 A 0.2 A 15 A 208 V 1 PP1 43,45 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR3-4 30 W 0.2 A 0.2 A 15 A 208 V 1 PP1 46,48 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR4-1 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 21,23 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR4-2 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 21,23 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR4-3 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 21,23 1 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR4-4 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 21,23 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HR4-5 30 W 0.2 A 0.2 A 15 A 208 V 1 PP3 21,23 33 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 HWRP1 151 W 1.4 A 1.8 A 15 A 120 V 1 PP1 50 168 VA HVAC 2#12,#12G,3/4"C TOGGLE DIV. 26 HWRP2 86 W 0.8 A 1.0 A 15 A 120 V 1 PP1 50 96 VA HVAC 2#12,#12G,3/4"C TOGGLE DIV. 26 KEF-1 1200 W 3.7 A 4.6 A 15 A 208 V 3 KP 29,31,33 1333 VA HVAC 3#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc MAU-1 2237 W 6.9 A 8.6 A 15 A 208 V 3 KP 30,32,34 2486 VA HVAC 3#12,#12G,3/4"C NFS DIV. 26 Weatherproof Disc P-1 728 W 3.5 A 4.4 A 15 A 208 V 1 PP1 51,53 728 VA HVAC 2#12,#12G,34'C NFS DIV. 26 P-2 728 W 3.5 A 4.4 A 15 A 208 V 1 PP1 51,53 728 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 Proj Scr 540 W 5.0 A 6.3 A 15 A 120 V 1 PP1A 49 600 VA Other 2#12,#12G,3/4"C Rolling Divider 1058 W 10.9 A 13.6 A 15 A 120 V 1 PP1A 32 1176 VA Other 2#12,#12G,3/4"C UH-1 180 W 1.5 A 1.9 A 20 A 120 V 1 PP1 1 180 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 UH-2 120 W 1.0 A 1.3 A 20 A 120 V 1 PP1 29 120 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 UH-3 180 W 1.5 A 1.9 A 20 A 120 V 1 PP1 29 180 VA HVAC 2#12,#12G,3/4"C NFS DIV. 26 Vertical Partition 1555 W 5.3 A 6.7 A 15 A 208 V 3 PP1A 33,35,37 1728 VA Other 3#112,#12G,3/4"C STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 0 0 x O O V W WaA►� w M= I~ 0 I • 1 I� MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT06067 P. (860) 436-4336 Fr (860) 436-4450 YMMizdesigeassociates. com ��1,11t1S1'lllill/f •,: , r,•,•x,-. fit';= N0. 3 N MOSER PILON NELS(D)N ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 ( 8 6 0 ) 5 6 3 - 6 1 6 4 TITLE ELECTRICAL SCHEDULES DATE 11 /2/201 S COPYRIGHT (C) Moser Pilon Nelson Architects DWG. NO. E591 0 0 N i N E z U N .o z CL REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 O 0 �_ V1 I� O wO w W a `� O 0 V1 • I� i I� I� MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT06067 Pr (860) 436-4336 F. (860) 436.4450 www.rzdesignassociates.com � � s `. 2 r 7� N0.25239 � s� . ENSE I MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL SCHEDULES DATE 11/2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E5o2 AL 001 rf LOCATION: MAIN DEVICE: BUS AMPS: SWITCHBOARD: MSB VOLTAGE: 480/277 Wye 1200 A AIC RATING: 22,000 1200 SPECIAL: MAIN SECTION C.T. COMPARTMENT: CURRENT TRANSFORMER, POTENTIAL TRANSFORMER CUSTOMER POWER QUALITY METER MAIN DEVICE FRAME POLES BREAKER SPECIAL DESCRIPTION/NAMEPLATE 1200 3 1200 LSIG Main Circuit Breaker DISTRIBUTION SECTION No. 1 CKT FRAME _ POLES 3 LOAD 911665 V,4 DESCRIPTION/NAMEPLATE Notes 1 1200 A ATS-SB LSIG 2 30 A n J r_nww lin nrc+ me 1 QI/'_T Distribution Notes: Panel: MDP Location: Supply From: ATS-SB Mounting: Floor Enclosure: 1 Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 1200 A MCB Rating: 1200 A CKT Circuit Description Type Trip Poles Load 1 LP1 80 A 3 31786 VA 2 MP1 400 A 3 281898 VA 3 T-1 500 A 3 364867 VA 4 MP2 300 A 3 233115 VA 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Legend: Blank =Standard, AFI =Arc Fault Circuit Interrupter, GFI =Ground Fault Circuit Interrupter, EPD =Equipment Protection Conditioning, Refrigeration Circuit Breaker I Device, ST =Shunt Trip Circuit Breaker, HACR =Heating, Air Load Classification Connected Load Demand Factor Estimated Demand Panel Totals � HVAC 553181 VA 100.00% 553181 VA Motor 416 VA 125.00% 520 VA Total Conn. Load: 911665 VA Other 136614 VA 100.00% 136614 VA Total Est. Demand: 838783 VA MTR 233 VA 125.00% 291 VA Total Conn.: 1097 A RCPT 160236 VA 53.12% 85118 VA Total Est. Demand: 1009 A LITES 39031 VA 125.00% 48789 VA KTCH 21953 VA 65.00% 14270 VA Notes: Distribution Notes: Panel: LVDP Location: MAIN ELECTRICAL 113 Supply From: T-1 Mounting: Surface Enclosure: 1 Volts: 208/120 Wye Phases: 3 Wires: 4 A.I.C. Rating: 10kA Mains Type: MCB Mains Rating: 1000 A MCB Rating: 1000 A CKT Circuit Description Type Trip Poles Load 1,2,3 PP1 400 A 3 139107 VA 4,5,6 PP2 400 A 3 162685 VA 7,8,9 KP 100 A 3 29592 VA 10,11,12 PP3 125 A 3 33483 VA 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Legend: Blank =Standard, AFI =Arc Fault Circuit Interrupter, GFI =Ground Fault Circuit Interrupter, EPD =Equipment Protection Conditioning, Refrigeration Circuit Breaker Device, ST =Shunt Trip Circuit Breaker, HACR =Heating, Air Load Classification Connected Load Demand Factor Estimated Demand Panel Totals HVAC 49803 VA 100.00% 49803 VA Motor 416 VA 125.00% 520 VA Total Conn. Load: 364867 VA Other 124980 VA 100.00% 124980 VA Total Est. Demand: 284039 VA MTR 233 VA 125.00% 291 VA Total Conn. Current: 1013 A RCPT 160236 VA 53.12% 85118 VA Total Est. Demand Current: 788 A LITES 7245 VA 125.00% 9057 VA KTCH 21953 VA 65.00% 14270 VA Notes: Branch Panel: LP1 Location: MAIN ELECTRICAL 113 Supply From: MDP Mounting: Surface Enclosure: 1 Notes: Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 125 A CKT Circuit Description Type Trip Poles A B C Poles Trip Type Circuit Description CKT 1 SITE LITES VIA LCP 20 A 1 2.1 1.0 1 20 A LITES VIA LCP 2 3 SITE LITES VIA LCP 20 A 1 1.6 2.1 1 20 A LITES VIA LCP 4 ¢ V 1 Irrn LI I CJ nn LU n H w I n o G.o 4 G I.V a I nn n GV h 1 ITCO u l co c V 7 LITES VIA LCP 20 A 1 0.0 0.0 -- -- -- Space 8 9 Spare -- 20 A 1 0.0 0.0 -- -- -- Space 10 11 Spare -- 20 A 1 0.0 0.0 -- -- -- Space 12 13 LP2 60 A 3 6.2 0.0 -- -- -- Space 14 15 8.0 0.0 -- -- -- Space 16 17 _ 6.5 0.0 -- -- -- Space 18 Total Load: Total Amps: 9.2 kVA 33 A 11.7 kVA 10.9 kVA 43 A 40 A Legend: I AFI =Arc Fault Circuit Interupter, GFI =Ground Fault Circuit Interupter, EPD =Equipment Protection Device, ST =Shunt Trip Circuit Breaker Load Classification Connected Load Demand Factor Estimated Demand Pane! Totals LITES 31786 VA 125.00% 39732 VA Total Conn. Load: � 31786 VA Total Est. Demand: 39732 VA Total Conn.: 38 A Total Est. Demand: 48 A Notes: Branch Panel: LP2 Location: ELECTRICAL CLOSET 125 Supply From: LP1 Mounting: Surface Enclosure: 1 Notes: Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 125 A CKT Circuit Description Type Trip Poles A B C Poles Trip Type Circuit Description CKT 1 LITES CORRIDOR-1 VIA LCP2 20 A 1 0.5 2.4 1 20 A LITES ENGLISH LEARNERS 127 2 3 LITES GRADES 1-2 CLASSROOM 135 20 A 1 2.7 0.8 1 20 A LITES READING INTERVENTION 139 4 5 LITES KINDERGARTEN 134 20 A 1 2.3 1.2 1 20 A LITES ELECTRICAL CLOSET 125 6 7 LITES 20 A 1 2.7 0.6 1 20 A LITES VIA LCP2 8 9 LITES 20 A 1 2.6 1.9 1 20 A LITES MAIN OFFICE SECRETARIAL... 10 11 LITES 20 A 1 1.2 1.7 1 20 A LITES (Alt #1) 12 13 LITES VIA LCP2 20 A 1 0.0 0.0 -- -- -- Space 14 15 Spare -- 20 A 1 0.0 0.0 -- -- -- Space 16 17 � Spare - 20 A 1 0.0 0.0 -- -- -- Space 18 Total Load: Total Amps: 6.2 kVA 22 A 8.0 kVA 6.5 kVA 29 A 24 A Legend: AFI =Arc Fault Circuit Interupter, GFI =Ground Fault Circuit Interupter, EPD =Equipment Protection Device, ST =Shunt Trip Circuit Breaker Load Classification Connected Load Demand Factor Estimated Demand Panel Totals LITES 20624 VA 125.00% 25780 VA Total Conn. Load: 20624 VA Total Est. Demand: 25780 VA Total Conn.: 25 A Total Est. Demand: 31 A Notes: Branch Panel: MP1 Location: MAIN ELECTRICAL 113 Supply From: MDP Mounting: Surface Enclosure: 1 Notes: Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 400 A CKT Circuit Description Type Trip Poles A B C Poles Trip Type Circuit Description CKT � 1 AC-1 50 A 3 11.4 11.4 3 50 A AC-2 2 3 11.4 11.4 4 5 11.4 11.4 6 7 AC-3 35 A 3 6.9 11.4 3 50 A AC-4 8 9 6.9 11.4 10 11 6.9 11.4 12 13 DOAS-1 90 A 3 21.7 17.9 3 90 A DOAS-2 14 15 21.7 17.9 16 17 21.7 17.9 18 19 AIR CURTAIN C-1 20 A 3 4.3 8.9 3 50 A HP-3 20 21 4.3 8.9 22 23 4.3 8.9 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 3g 40 41 42 Total Load: Total Amps: 94.0 kVA 339 A 94.0 kVA 94.0 kVA 339 A 339 A Legend: AFI =Arc Fault Circuit Interupter, GFI =Ground Fault Circuit Interupter, EPD =Equipment Protection Device, ST =Shunt Trip Circuit Breaker Load Classification Connected Load Demand Factor Estimated Demand Panel Totals HVAC 281898 VA 100.00% 281898 VA Total Conn. Load: 281898 VA Total Est. Demand: 281898 VA Total Conn.: 339 A Total Est. Demand: 339 A Notes: Branch Notes: Panel: EL1 Location: MAIN ELECTRICAL 113 Supply From: ATS-EM Mounting: Surface Enclosure: 1 Volts: 480/277 Wye Phases: 3 ' Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 125 A CKT Circuit Description Type Trip Poles A B C Pole: Trip Type Circuit Description CKT 1 EL2 30 A 3 0.6 0.4 1 20 A EMERGENCY LITES 2 3 0.9 0.9 1 20 A EMERGENCY LITES 4 c �7 � n t.Y � � 1. t a 1 �n e LV /'1 GnnGl�r_Gnlry LIrGc LIVII-1�v Llvv 1 111-v 5 7 Spare -- 20 A 1 0.0 0.0 -- -- -- Space 8 9 Spare -- 20 A 1 0.0 0.0 -- -- -- Space 10 11 Spare -- 20 A 1 0.0 0.0 -- -- -- Space 12 13 Space -- -- -- 0.0 0.0 -- -- -- Space 14 15 Space -- - -- 0.0 0.0 -- -- - Space 16 17 Space -- -- -- 0.0 0.0 -- -- -- Space 18 Total Load: Total Amps: 1.0 kVA 4 A 1.8 kVA 2.5 kVA 7 A 10 A 1 cnnnA• AFI =Arc Fault Circuit Interupter, GFI =Ground Fault Circuit Interupter, EPD =Equipment Protection Device, ST =Shunt Trip Circuit Breaker Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Other 60 VA 100.00% 60 VA LITES 525'I VA 125.00% 6564 VA Total Conn. Load: 5311 VA Total Est. Demand: 6624 VA Total Conn.: 6 A Total Est. Demand: 8 A Notes: - - Branch Panel: EL2 Location: ELECTRICAL CLOSET 125 Supply From: EL1 Mounting: Su Volts: 480/277 Wye Phases: 3 A.I.C. Rating: 22,000 Mains Type: MLO Branch Notes: Panel: MP2 Location: ELECTRICAL CLOSET 125 Supply From: MDP Mounting: Surface Enclosure: 1 Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: MLO Mains Rating: 400 A CKT Circuit Description Type Trip Poles A B C Poles Trip Type Circuit Description CKT 1 DOAS-3 100 A 3 25.4 8.9 3 50 A HP-1 (A) 2 3 25.4 8.9 4 5 25.4 8.9 6 7 HP-2 50 A 3 9.5 9.5 3 50 A HP-1 (B) 8 9 9.5 9.5 10 11 9.5 9.5 12 13 HP-4 (A) 25 A 3 4.4 6.6 3 35 A HP-4 (B) 14 15 4.4 6.6 16 17 4.4 6.6 18 19 ELEVATOR 30 A 3 3.9 9.5 3 50 A HP-4(C) 20 21 3.9 9.5 22 23 3.9 9.5 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Total Load: Total Amps: 77.7 kVA 281 A 77.7 kVA 77.7 kVA 281 A 281 A Legend: AFI =Arc Fault Circuit Interupter, GFI =Ground Fault Circuit Interupter, EPD =Equipment Protection Device, ST =Shunt Trip Circuit Breaker Load Classification Connected Load Demand Factor Estimated Demand Panel Totals HVAC 221481 VA 100.00% 221481 VA Other 11634 VA 100.00% 11634 VA Total Conn. Load: 233115 VA Total Est. Demand: 233115 VA Total Conn.: 280 A Total Est. Demand: 280 A Notes: (2)#16 TW/SH/PAIR REVISIONS CONFORMED SET MARCH 22, 2019 (2)#16 TW/SH/PAIR & (2) 12#AWG 1N DEVICES FAA VESTIBULE FACP BA 1v1 DUCT SMOKE DETECTORS WITH REMOTE TEST D S D S D SWITCHES - RTS'S TO BE LOCATED IN THE FIELD AS DIRECTED BY THE ENGINEER. DETECTOR TO QL11 ITr1f11A1n1 AQQfIf`IATGrI I IMIT VIA Anr1Rt=CCARI F SIIUMOANASSMAEDUNII 31, RTS RTS CONTROL MODULE. DUCT SMOKE DETECTORS SHALL INITIATE A SUPERVISORY CONDITION IN THE r (2)#16 TW/SH/PAIR FACP (WILL NOT ALARM THE BUILDING). INITI (2)#16 TW/SH/PAIR THEATRICAL DIMMING CABINET CARBON MONOXIDE DETECTOR SHALL ACTIVATE A SUPERVISORY SIGNAL AT THE MAIN FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR, AS A SEPARATE ZONE (CO DETECTOR WILL NOT ALARM THE BUILDING.) MM MM MM MM E (2)#12AWG. EACH EOL FS EOL EOL 2#12AWG., 3/4"C TO 20 AMP-1 P C/B. W/ LOCK TS PS ANSUL SYSTEM 1#10AWG., 3/4"C TO BUILDING STEEL SPRINKLER SYSTEM DEVICES 120V E 1 2/19/19 BID SUPPLEMENT 1 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 NOTES: 1. ALL WIRING PER MANUFATURERS RECOMMENDATIONS TO BE INSTALLED IN AN APPROVED RACEWAY SYSTEM. O 2. THIS DIAGRAM IS INTENDED TO SHOW THE GENERAL RELATIONSHIP OF O DEVICES AND CONTROL PANEL IS NOT INTENDED TO SHOW ALL DEVICES. REFER TO FLOOR PLANS FOR EXACT QUANTITIES AND LOCATION OF ALL DEVICES. 3. DIVISION 26 CONTRACTOR TO PROVIDE AND SUPPLY ALL DUCT MOUNTED r l SMOKE DETECTORS TO THE DEVISION 23 CONTRACTOR FOR v INSTALLATION IN THE DUCT. DIVISION 26 CONTRACTOR SHALL BE T^ RESPONSIBLE FOR WIRING OF DUCT DETECTORS. V1 1 FIRE ALARM RISER DETAIL t� E6.2 NTS O Q � O � Ww� h tx ►� W � A O �w� 1 1/2" ID SCH. 40 X34'-0" BLACK BATTEN PIPE---------- t 1 m.,®�,,. 1 � �.v. i I �-■• 1 1 1 1 ®o.e,° t � mc®o• 1 I (1) DMX CONTROL DAT CABLE FROM VN/DMX/OSPTOSPLITTER INTERFACE (2) 20A, 120VAC NON -DIM CIRCUIT FROM TDC LOCATE ON END OF PIPE CLOSET /! TO TDC PANEL � WASH LIGHT: TYPE 'THT ALTMAN #SSCYC100-RGBA-B/SS-CYC100- DOWNSTAGE (� YOKEB (10OW LED) OR EQUAL (I YP.) 1 1/2" ID SCH. 40 X34'-0" BLACK BATTEN PIPE --- --- --- ----- — i (1) DMX CONTROL DAT CABLE FROM— VN/DMX/OSPTOSPLITTER INTERFACE-- ° (2) 20A, 120VAC NON -DIM CIRCUIT FROM TDC LOCATE ON END OF PIPE CLOSET / I \ TO TDC PANEL FRESNEL SPOT: TYPE 'TH2' STRAND #PLFR1 MKII-03-GR UPSTAGE I� T FIXTURE CAGE (140W LED) OR EQUAL (TYP.) -A --A T FIXTURE CAGE ' w (1) DMX CONTROL DAT CABLE FROM VN/DMX/OSPTOSPLITTER INTERFACE (1) 20A, 120VAC NON -DIM CIRCUIT FROM TDC PANEL 20" LCD MONITOR 250 ML LIGHTING CONTROL CONSOLE GENERAL NOTES 1. CONTRACTOR IS RESPONSIBLE FOR ALL PROGRAMMING, TUNING AND CONFIGUATION OF SYSTEM. 2. SYSTEM SHALL BE COMPLETE, INCLUDING ALL MOUNTING HARDWARE AND ACCESSORIES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL BATTENS, RAILS, ETC. 3. PROVIDE ALL NECESSARY POWER AND DMX CABLES BETWEEN FIXTURES AS REQUIRED BY MANUFACURES. 4. UPON EXITING GYNASIUM AND AFTER THIRTY(30) MINUTES, OCCUPANCY SENSORS SHALL SHUT ALL HOUSE LIGHTS OFF 5. REFER TO LIGHTING FIXTURE SCHEDULE FOR LUMINARE MODEL NUMBERS AND DESCRIPTIONS. 6. REFER TO SPECIFICATIONS FOR ADDITIONAL EQUIPMENT INFORMATION AND MODEL NUMBERS. 0 0 N L E z U n z IL 1-m a-1 1-m a-i J (1) DMX CONTROL DAT CABLE FROM VN/DMX/OSPTOS P LITTER INTERFACE (1) 20A, 120VAC NON -DIM CIRCUIT FROM TDC PANEL FRONT OF HOUSE W) SYMBOL: DMX DMX-IN RECEPTACLE 1-GANG, MOUNT 18" A.F.F. 25' DMX EXTENSION CABLE PRVIDE TWO(2) EXTENSION CABLES (ONE AS SPARE) HIGH BAY OCCUPANCY SENSORS (SEE FLOOR PLAN FOR QUANTITY/LOCATIONS) SYMBOL: TS TOUCHSCREEN STATION, FLUSH MOUNT 48" A.F.F. (2) #14 WIRES) 500' MAX (V+, COM) ' 0 POWER VIA POWER LOCAL 120V SUPPLY UNSWITCHED CIRCUIT I t SYMBOL: ES ENTRY STATION, MOUNT 48" A.F.F. SYMBOL: DMX DMX-IN RECEPTACLE 1-GANG, MOUNT 18" A.F.F. SYMBOL: 232 PROGRAMING STATION, MOUNT 18" A.F.F. THEATRICAL LIGHTING RISER DIAGRAM 1 " = 1'-011 FIRE ALARM CONTROL MODULE TO TRANSFER TO EMERGENCY SOURCE (FULL OUTPUT) UPON FIRE ALARM ACTIVATION. TO EMERGENCY CIRCUITS (TYP) TO NORMAL CIRCUITS (TYP) DMX INTERFACE AND POWER SUPPLY W/4 PORT OPTOSPLITTER FROM LOCAL 277V EMERGENCY LIGHTING CIRCUIT CM E1 ELLIPSOIDAL SPOT: TYPE'TH1' STRAND #PLZS1 MKII-1834-03-GR (140W LED) OR EQUAL (TYP.) 2kVA, 277-120V TRANSFORMER TYPICAL FOR ALL EMERGENCY LOADS PROVIDE DIMMING -COMPATIBLE UL LISTED TRANSFER RELAY, LOCATE ADJACENT TO PANEL TDC. 2#12,#12G,3/4"C EACH MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SUITE 202 ROCKY HILL, CT 06067 Pa (860) 436-4336 Fe (860) 436-4450 www.rzdesignassociates.com "� O� _ 1'tii��.'�s. W. C D T ^°�, V•�P.,.�.��9,� +ems. kec' 25239 E 0 0 0 0 0 0 0 0 MOSER ®� PILON 0 0 o �= NELSON 0 0 ° THEATRICAL DIMMER CABINET (TDC) 208/120VAC, THREE PHASE WITH: (1) QUAD NON -DIM MODULES (2) QUAD 2000WATT VA 0-10VDC DIMMER MODULE (1) AUX. BREAKER KIT ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRICAL RISER DIAGRAM DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E6*2 REVISIONS CONFORMED SET MARCH 22, 2019 — — -- --I GWH2 LEMERGENCY DISCONNECT SWITCHES FOR WATER HEATER AND BOILER CIRCUITS (TYP.) PP1-50 ROUTE POWER CIRCUITS THROUGH EMERGENCY DISCONNECT SWITCHES. MECHANICAL i 114 GWH1 PP1- P PP1-36` I PPI-51,53-- n I F ELECTRICAL PART PLAN - MECH RM 1 1A 11 = 11 Aff I -r 1 - V STRUCTURE (TYP) MECHANICAL FASTENER (TYP) #10 AWG STEEL SUPPORT WIRE (TYP) CEILING TEE (TYP) RECESSED TROFFER LIGHT FIXTURE (TYP) TYPICAL RECESSED TROFFER LIGHT SUPPORT DETAIL B� (5) 4" CORI ON B mel 2 ELECTRICAL PART PLAN - MDF F7-1 1 1 1A 11 = 1 I_n11 — LIGHTING CONTROL PANEL (LCP & LCP2): WITH LCD USER INTERFACE KEYPAD, 365 DAY PROGRAMMING, 64 SCHEDULES, REAL AND ASTRONOMICAL TIMECLOCK, (8) 30A LATCHING RELAYS. HUB BELL #CSV82SU83L OR EQUAL DD FF HH II�H, 12" CABLE LADDER RACK MOUNTED 1 AT 9'AFF i_ (4) 4' SLEEVESL\ THROUGH FLOOR — - 15 F — — — I 16 3-18 PP3-20 O I PP3-22 J&20R 0R L5.2 LS20R OF 20 6.30R L530R L6.30R L5.30R L6.30R L5.30R I I + i (4) 4' SLEEVES TO I I I ' r I I i A, Ii nnnn VVID a Imu I,VtCI�. VVIDUJI"IIIVU ti aa- a s 0- a 0- u u u - 3 ELECTRICAL PART PLAN - IDF E7.1 1 1 1A11 — 11_n" LCP RELAY SCHEDULE RELAY # CKT # SCHEDULE 1 LP1-1 SITE LIGHTING DUSK-11PM 2 LP1-3 SITE LIGHTING DUSK-9PM 3 LP1-3 FLAGPOLE LIGHTING DUSK -DAWN 4 LP1-7 EXTERIOR BLDG LIGHTING DUSK-11PM 5 LP1-2 CORRIDOR LIGHTING 1 HR BEFORE OPENING-1 HR AFTER CLOSE 6 LP1-4 CORRIDOR LIGHTING 1 HR BEFORE OPENING-1 HR AFTER CLOSE 7 SPARE 8 SPARE LCP2 RELAY SCHEDULE NTS RELAY # CKT # SCHEDULE 1 LP2-13 EXTERIOR BLDG LIGHTING DUSK-11 PM 2 LP2-1 CORRIDOR LIGHTING 1 HR BEFORE OPENING-1 HR AFTER CLOSE 3 LP2-8 lni O R RIDOR LIGHTING VG I I1-1-IR BCFORC OPEIV IIVG- 1 HR AFTER lniLOSE 4 SPARE 5 SPARE 6 SPARE 7 SPARE 8 SPARE TYPICAL EXIT SIGN 8'-0" AFF EGRESS PATH ARCHITECTUR, EXIT 8 EXIT SIGNAGE DETAIL E7.1 NTS ACCESSIBILITY EXIT SIGN FOR EGRESS (WHERE NOTED) 8'-0" AFF X LIGHTING CONTROL PANEL DETAIL E7.1 NTS ROOFTOP EQUIPMENT FS BOX WITH RECEPTACLE AND "WEATHERPROOF WHILE IN USE" COVER 1" RIGID GALVANIZED CONDUIT PITCH POCKET SUPPORT TO BUILDING STRUCTURE 24" ROOF ROOF RECEPTACLE - MOUNTING DETAIL NTS TYPICAL RECESSED DOWNLIGHT SUPPORT DETAIL NTQ DRY -TYPE TRANSFORM EQUIPMENT JUMPER (SI_ NEC 250.66) NEAREST GROUNDING ELECTRODE FLOOR iKuuiUKL(I'r'r) MECHANICAL FASTENER (TYP) #10 AWG STEEL SUPPORT WIRE (TYP) FINISH CEILING T-BAR (TYP) RECESSED DOWNLIGHT FIXTURE (TYP) SEISMIC CLIPS AT FOUR CORNERS (TYP) 480 V EQUIPMENT GROUNDING V SYSTEM BONDING JUMPER ISOLATED NEUTRAL TERMINAL \ GROUNDING ELECTRODE CONDUCTOR (#8) TRANSFORMER GTROITI DING T)F_.TATT. NTS /— OVERHEAD STRUCTURE 3/4" CONDUIT (TYP) ATTACH CABLE TO OVERHEAD STRUCTURE 1/16" AIRCRAFT CABLE ATTACH CABLE TO FIXTURE 10 PENDANT FIXTURE DETAIL E7.1 NTS A.F.F. STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 o_ V TT� V1 o � l T^ l•w O v � r-� PLO ww 1 wl 1► w � MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAm STREET suirE 202 ROCKY wu, cr 06067 P. (860) 436-4336 F. (860) 436-4450 www.rzdesignassociates.com K`..In* N0.25239 ; s. C _NgE,�� AL MOSER PILON NELSON ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 663-6164 TITLE ELECTRICAL DETAILS DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E7.1 REVISIONS CONFORMED SET MARCH 22, 2019 NEUTRAL (WHITE) 1 TRAVELERS BETWEEN SWITCHES "IN" 2 TRAVELERS BETWEEN SWITCHES "OUT" ISD DC DIMMER HOT BLACK NEUTRAL (WHITE) PURPLE GRAY RED RED THREE -LOCATION CONTROL APPLICATION NTS 3-WAY SWITCH v o �% - COw1ww^N TERMINAL C� (LOAD) I BLACK o, �--,0 I GREEN GROUND TWO LOCATION CONTROL APPLICATION NTS DIMMER SINGLE -LOCATION CONTROL APPLICATION NTS GREEN GROUND CLASS 2 CONDUCTORS ISD DC DIMMER CLASS 2 CONDUCTORS 1 WHITE PURPLEI IGRAY 0-10Vdc BALLAST - --ADVANCE MARK VII COMPATIBLE DIMMING BALAST TO LAMPS ,K VII AST CRIMP/COMPRESSION CONNECTION AT THE INTERIOR GND RING - - ---- ROUND OFF EDGES -- --- --- 'MASTER GROUND BAR'-- 3/8" x4"x18-1/4" SOLID COPPER BAR WITH (8) SETS OF (2) - 3/8 HOLES FOR TERMINAL LUD CONNECTION(S). CHAMFER ALL EDGES BAR TO BE MTD. ON 2-1/2"'RED GLASTIC' INSI II ATnRS -- 3/8" MASONRY ANCHOR --- - HEX BOLT 3/8" x1 - 1/2" WITH 1/2" HEAD. INSTALL WITH 3/8"x1/2" LOCK - WASHER & 3/8"x1/2" FLAT - WASHER -- 2" MAIN WATER SERVICE AT POOL EQUIPMENT REF. NEC 250-52(A)(1) CONCRETE ENCASED ELECTRODE, REF. INSTALLED PER NEC 250-52(A)(3) o MAIN ELECTRICAL SERVICE ENTRANCE EQUIPMENT A r MA$TFR CR01 JND BAR DETAIL E7.2 NTS NEUTRAL BAR BONDING CONDUCTOR GROUND BAR BONDING CONDUCTOR \ _ TO UTILITY XFMR GROUND ROD & PIPE ELECTRODES REF. NEC 250-52(A)(5) BUILDING STEEL - — REF. NEC 250-52(A)(2) 4" MAIN WATER SERVICE LOWER LEVEL MECHANICAL ROOM NEAR ELEVATOR REF. NEC 250-52(A)(1) NOTES: A. REFER TO GROUNDING ELECTRODE TABLE FOR CONNECTIONS REQUIRED AS RELATED TO THIS PROJECT. B. ALL CONNECTIONS SHALL BE IN ACCORDANCE WITH NEC ARTICLE 250. WATER MAIN---- - GROUNDING ELECTRODE CONNECTIONS AVAILABILITY AND REQUIREMENTS FOR THIS PROJECT NEC AVAIL.TREaD NOTES YESYES 250-52(A)(1) X X 1 250-52(A)(2) X X 1 250-52(A)(3) X X 1,4 250-52(A)(4) X X 2 - 250-52(A)(5) X X 2 250-52(A)(6) X X 2 250-52(A)(7) X 2 -- GROUNDING ELECTRODE CONDUCTOR SIZE:3/0 AWG COPPER NOTES: 1. NEC ARTICLE 250-52 INDICATES A PRIORITY LIST OF GROUNDING ELECTRODE CONNECTIONS WITH (1) BEING THE HIGHEST PRIORITY AND (7) BEING THE LOWEST. 2. CONNECTION TO ITEMS MADE UNDER ARTICLE 250-52(A)(4),(5),(6) & (7) SHALL NOT SUBSTITUTE CONNECTIONS TO 250-52 (1), (2), OR (3), UNLESS NONE OF THESE SYSTEMS ARE AVAILABLE. 3. GROUNDING ELECTRODE SYSTEM INSTALLATION SHALL COMPLY WITH NEC ARTICLE 250.53. 4. REFER TO NEC ARTICLE 250.50, EXCEPTION. GROUNDING ELECTRODE SYSTEM DETAIL NTS TRANSFORMER ENCLOSURE -- SECONDARY MAIN DISCONNECT -- - �� ISOLATED F) GROUND BUS DJ ` OE I INSULATED NEUTRAL BUS GROUND BUS XO (NEUTRAL) TERMINAL C - - - BOND TO ENCLOSURE -- BOND TO LOCAL COLD WATER PIPE B A BOND TO NEAREST EFFECTIVELY GROUNDED BUILDING STEEL OR EFFECTIVELY GROUNDED METAL WATER PIPE WITHIN 5 FEET FROM THE POINT OF ENTEREANCE INTO THE BUILDING PER NEC. AO GROUDING ELECTRODE CONDUCTOR (REFER TO 'GROUND & CONDUIT IN TRANSFORMER SCHEDULES FOR CONDUCTOR AND CONDUIT SIZE). B� BONDING JUMPER (REFER TO 'GROUND & CONDUITIN TRANSFORMER SCHEDULES FOR CONDUCTOR AND CONDUIT SIZE). O BONDING JUMPER (REFER TO GROUND CONDUCTOR SIZE IN 'SECONDARY FEEDER' IN TRANSFORMER SCHEDULES). OGROUNDED (NEUTRAL) CONDUCTOR (REFER TO 'SECONDARY FEEDERFOR CONDUCTOR SIZE). E MAIN BONDING JUMPER CONDUCTOR (REFER TO - GROUND CONDUCTOR SIZE IN 'SECONDARY FEEDERIN TRANSFORMER SCHEDULES). MAIN BONDING JUMPER CONDUCTOR TO BE RUN IN EACH CONDUIT CONTAINING PHASE CONDUCTORS BETWEEN TRANSFORMER AND MAIN SECONDARY DISCONNECT. F ISOLATED EQUIPMENT GROUND CONDUCTOR (REFER TO 'SECONDARY FEEDERIN TRANSFORMER SCHEDULES FOR ISOLATED GROUND CONDUCTOR SIZE). NOTE: ISOLATED GROUND BUS AND ASSOCIATED ISOLATED EQUIPMENT GROUND CONDUCTOR SHALL BE PROVIDED BETWEEN K-RATED TRANSFORMERS AND SECONDARY MAIN DISCONNECT SERVING ELECTRONIC GRADE PANELBOARDS WITH INTEGRAL SPD. NOTES TO ENGINEER: 1. THIS DETAIL IS TO BE PLACED ON THE SAME DRAWING AS THE TRANSFORMER SCHEDULES. 2. BOTH GROUNDS (LABELED WITH TAGS "A" AND "B") ARE REQUIRED FOR STEPDOWN TRANSFORMERS AND ARE NOT REDUNDANT. THE GROUND TAGGED "A" IS THE GROUNDING ELECTRODE CONDUCTOR USED TO DERIVE THE NEUTRAL (GROUNDED CONDUCTOR). THE GROUND TAGGED "B" IS A BOND BETWEEN THE TRANSFORMER'S GROUNDING ELECTRODE AND LOCAL WATER PIPE (POSSSIBLY TO PREVENT VOLTAGE BEING MAINTAINED ON METAL PIPES WITHIN THE BUILDING). DISTRIBUTION TRANSFORMER GROUNDING DETAIL NTS STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 94 - � C 1 r> 0 I� �I MECHANICAL AND ELECTRICAL ENGINEERING 750 OLD MAIN STREET SVITE202 ROCKYH/LL, cT 06067 P. (860) 436-4336 F. (860) 436-4450 www.rzdesignassociates.com ON q�C�,'� �-0 `N0. 25239 O �,/SENSE ON /lltail MOSER PIL""N 'N NELSu ARCHITECTS 30 JORDAN LANE WETHERSFIELD, CT. 06109 I (860) 563-6164 TITLE ELECTRICAL DETAILS I I 1 DATE 11 /2/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. AMIL M PS ILi O REVISIONS TECHNOLOGY ABBREVIATIONS (NOTE: NOT ALL ABBREVIATIONS APPLICABLE) -am ABOVE MILLWORK, COORDINATE LOCATION IWB INTERACTIVE WHITE BOARD WITH MILLWORK OR FURNITURE SYSTEM JB JUNCTION BOX AFF ABOVE FINISH FLOOR LAN LOCAL AREA NETWORK A r r• M.F.U. ADnvM MMIQU nonnc MDVVF- r11v10n Urvwuc LSER LOCAL SOUND EQUIPMENT RACK AMP AMPERE MDF MAIN DISTRIBUTION FRAME ARCH. ARCHITECT NEC NATIONAL ELECTRICAL CODE AWG AMERICAN WIRE GAUGE NIC NOT IN CONTRACT BCT BONDING CONDUCTOR FOR PA PUBLIC ADDRESS TELECOMMUNICATIONS PBX PRIVATE BRANCH EXCHANGE BICSI BUILDING INDUSTRY CONSULTING SERVICE PC PERSONAL COMPUTER INTERNATIONAL PoE POWER OVER ETHERNET -c AT CEILING OR IN CEILING TILE, LOCATION OF DEVICE PP PATCH PANEL C CONDUIT(S) PR PAIR CAT CATEGORY ETHERNET CABLE PVC POLYVINYL CHLORIDE CONDUIT CATV COMMUNITY ANTENNA TELEVISION (CABLE QTY QUANTITY TELEVISION) RJ REGISTERED JACK CCTV CLOSED CIRCUIT TELEVISION RU RACK UNIT CLG. CEILING -r IN RACEWAY ABOVE MILLWORK, MOUNTING CPU CENTRAL PROCESSING UNIT LOCATION CT CABLE TRAY S SLEEVE(S) D DATA T TELEPHONE (VOICE) DEMARC DEMARCATION TBB TELECOMMUNICATIONS BONDING BACKBONE DP DEMARCATION POINT TC TELECOMMUNICATIONS CONTRACTOR E.C. ELECTRICAL CONTRACTOR TGB TELECOMMUNICATIONS GROUNDING BUSBAR' EF ENTRANCE FACILITY TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATIONS ELEC ELECTRICAL TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR EMI ELECTRO MAGNETIC INTERFERENCE TR TELECOMMUNICATIONS ROOM EMT ELECTRICAL METALLIC TUBING TV TELEVISION -f AT FLOOR OR IN THE FLOOR, LOCATION OF DEVICE TYP TYPICAL F FACSIMILE (FAX) U.N.O. UNLESS NOTED OTHERWISE FD FLOOR DISTRIBUTION UPS UNINTERRUPTIBLE POWER SUPPLY F.O. FIBER OPTICS UTP UNSHIELDED TWISTED PAIR FOPP FIBER OPTIC PATCH PANEL V VIDEO F&I FINISHED AND INSTALLED VGA VIDEO GRAPHICS ARRAY G GROUND VoIP VOICE OVER INTERNET PROTOCOL G.C. GENERAL CONTRACTOR W WALL TELEPHONE (VOICE) GE GROUNDING EQUALIZER WG WIRE GUARD GEC GROUNDING ELECTRODE CONDUCTOR WAN WIDE AREA NETWORK H HIGH DEVICE WAO WORK AREA OUTLET HVAC HEATING, VENTILATION AND AIR CONDITIONING WAP WIRELESS (DATA) ACCESS POINT ICHE INTERCOM HEAD END WP WEATHERPROOF IN USE ENCLOSURE IG ISOLATED GROUND XLR MICROPHONE ELEC. CONNECTOR OF INTERMEDIATE DISTRIBUTION FRAME PUBLIC ADDRESS/ INTERCOM SYSTEM SYMBOLS (NOTE: THIS SYSTEM SYMBOLS ARE FOR REFERENCE PURPOSES ONLY, SYSTEM SHALL BE PROCURED AS PART OF THE TECHNOLOGY SYSTEM PROCUREMENT PROCESS AT A LATER DATE. ALL BUILDING PREPARATION SHALL BE PROVIDED IN THE BASE BID) SYMBOL DESCRIPTION TYPICAL IBACK BOX 120 VAC NOTES LOCATION I PnWFR RY F C tPAiV PUBLIC ADDRESS / INTERCOM SPEAKER, FLUSH CEILING MOUNTED IN SPECIAL NONE REFER TO L C WC" = VOLUME CONTROL. CEILING NOTE A, D, L. PA PUBLIC ADDRESS / INTERCOM SURFACE MOUNTED SPEAKER WALL OR SPECIAL NONE REFER TO SM "SM" = SURFACE MOUNTED CEILING NOTE A, D, L. PA PUBLIC ADDRESS / INTERCOM FLUSH WALL MOUNTED REFER TO ARCHITECT'S SPECIAL NONE REFER TO -' FL "FL" =FLUSH MOUNTED DWGS NOTE A, D, L. FL A) SM PUBLIC ADDRESS /INTERCOM SPEAKER REFER TO SPECIAL REFER TO - RH "RH" = RE-ENTRANT HORN SPEAKER, "WP" =WEATHER PROOF, ARCHITECT'S NONE NOTE A, D, L. "SM" = SURFACE MOUNTED, "FL" = FLUSH WALL MOUNTED DWGS PAIMS 0 PAIMS - PUBLIC ADDRESS INTERCOM MASTER STATION CONSOLE. 18" AFF SINGLE GANG NONE REFER TO NOTE A, D, L. FACEPLATE Flc7s ICS - INTEGRATED COMMUNICATIONS SOUND HEADEND REFER TO REFER TO ENLARGED ENLARGED REFER TO REFER TO NOTE PLANS PLANS NOTE Y A, D, N, Y. CS VCS - VOLUME CONTROL SWITCH FOR ASSOCIATED PUBLIC ADDRESS / INTERCOM SPEAKER. 48" AFF SINGLE GANG NONE REFER TO NOTE A, D, L. FACEPLATE CLOCK SYSTEM SYMBOLS SYMBOL DESCRIPTION TYPICAL LOCATION gACKBOX 120 VAC NOTES POWER BY E.C. L CLOCK, SURFACE WALL MOUNTED 96" AFF SINGLE NONE REFER TO X X = DIAMETER (12" TYPICAL OR AS NOTED ON DRAWINGS) "C" = CLOCK CAGE ENCLOSURE GANG NOTE A, D, L. MCS MCS -MASTER CLOCK SYSTEM, HEAD END WALL OR RACK MOUNT NIA REFER TO NOTE X. REFER TO NOTE A, D. N, X. LOCAL SOUND SYSTEM SYMBOLS (NOTE: THIS SYSTEM SYMBOLS ARE FOR REFERENCE PURPOSES ONLY, SYSTEM SHALL BE PROCURED AS PART OF THE TECHNOLOGY SYSTEM PROCUREMENT PROCESS AT A LATER DATE. ALL BUILDING PREPARATION SHALL BE PROVIDED IN THE BASE BID) SYMBOL DESCRIPTION TYPICAL LOCATION TYPICAL FACEPLATE 120 VAC POWER BY E.C. NOTES REFER TO X LS LOCAL SOUND SPEAKER, FLUSH CEILING MOUNTED CEILING SPECIAL NONE NOTE "X" = SPEAKER TYPE A D J. REFER TO LS X LOCAL SOUND SPEAKER, SURFACE WALL MOUNTED MIN. 96" AFF SEE ARCH DWG DUAL GANG NONE N DT L MIN, 96" AFF REFER TO LS X 0 LOCAL SOUND SPEAKER, FLUSH WALL MOUNTED SEE ARCH DWG SPECIAL NONE NOTE A, D, J. S X LOCAL CLUSTER SOUND SPEAKER SUSPENDED FROM CEILING OR STRUCTURE SUSPENDED FROM SPECIAL NONE REFER TO NOTE CEILING A, D, J. @CM MICROPHONE OUTLET, FLUSH CEILING MOUNTED SINGLE GANG FACE PLATE REFER TO OCAL CONDENSER AUTO LEVEL SENSING MICROPHONE OUTLET, CEILING OR WALL FLUSH MOUNTED SINGLE GANG DECORA FACE PLATE CEILING SINGLE GANG NONE NOTE GRILL PAINTED TO MATCH WALL OR CEILING COLOR. MOUNTED FACE PLATE A, D, L. OOH GANG FACE PLATE OVERHEAD MICROPHONE CEILING MOUNTED SINGLE MICROPHONE OUTLET, FLUSH WALL MOUNTED SINGLE GANG NONE REFER TO 18" AFF FACE PLATE NOTE FO MICROPHONE OUTLET, SURFACE WALL MOUNTED A, D, L. PL IPLT - XLR MIC INPUT / MINI & RCA MONO LINE INPUT FLUSH WALL MOUNTED 48" AFF DUAL GANG FACE PLATE NONE REFER TO NOTE A, D, L. WEBA 18" AFF DUAL GANG REFER TO PROCO WEBA105 FRONT OF STAGE LEFT, DUAL INPUT MIC PLATE UNLESS NOTED BACK BOX NONE NOTE A, D, L. AND 1/8" MINI LINE AUDIO/INPUT JACK FLUSH WALL MOUNTED - CUSTOM PROCO PLATE TERMINATE W/ MALE CONNECTOR INSIDE SINGLE GANG REFER TO MIMICROPHONE M THE RACK (20' TAIL ONLY FOR THE BAND ROOM) 18" AFF FACE PLATE NONE NOTE A, D, L. WP WALL POCKET SEE LOCAL SOUND DETAILS, FLUSH WALL MOUNTED, UNLESS NOTED OTHERWISE IN WALL WALL POCKET NONE REFER TO NOTE A, D, L. RACK OR WALL SINGLE REFER TO REFER TOMOUNTED LS ASSISTIVE LISTENING SYSTEM: RACK OR WALL MOUNTED. GANG NOTE X. NOTE A, D, L. ANTENNA - ASSISTIVE LISTENING, WIRELESS MICROPHONES, WALL MOUNTED. REFER TO ANT-C A & B =ANTENNA FOR WIRELESS MICROPHONES 96" AFF SINGLE NONE NOTE A, D, L. C = ANTENNA FOR ASSISTIVE LISTENING SYSTEM GANG PPLCI RPLC - REMOTE PRESET / LEVEL CONTROL, RECALLING PRESETS FROM A REMOTE LOCATION AND LOCAL LEVEL CONTROL, FLUSH WALL MOUNTED REFER TO ARCH DWG OR SINGLE GANG BACK BOX NONE REFER TO F NOTE A, D, L. ECA RCS - REMOTE CONTROL SWITCH TO POWER ON THE SYSTEM FLUSH WALL MOUNTED 04" AFF SINGLE GANG NONE REFER TO NOTE A, D, L. HI HI - HEADSET INTERCOM OUTLET 18" AFF SINGLE GANG FACE PLATE NONE LSSA LOCAL SOUND SYSTEM AMPLIFIERIM►XER, WALL MOUNTED 48" AFF SPECIAL NOTE X REFER TO NOTE A D J X. LSER SPECIAL REFER TO RACK LOCAL SOUND EQUIPMENT RACK, FREE STANDING ON FLOOR SIZED FOR ALL NOTE X NOTE A, D, X. ITEMS MISCELLANEOUS BACK BOX, FLOOR BOX SYMBOLS TYPICAL ENCLOSURE 120 VAC SYMBOL DESCRIPTION LOCATION BACK BOX POWER BY E.C. NOTES DX INDICATES TELECOMMUNICATIONS OUTLETS MOUNTED IN COMBINATION ELECTRICAL / LOW VOLTAGE WIREMOLD EFB10S SERIES IN FLOOR MULTI FUNCTION ACCORDING TO REFER ME FLOOR BOX. TELECOMMUNICATIONS CONNECTOR TYPES AS INDICATED BY TELECOMMUNICATION SYMBOLS. FLOOR BOX BY E.C. FLOOR BOX ELECOM SYMBOL A NOTE A DX R INDICATES TELECOMMUNICATIONS OUTLETS MOUNTED IN COMBINATION ELEC. / LOW VOLTAGE FIRE RATED WIREMOLD 8AT SERIES. IN FLOOR MULTI FUNCTION ACCORDING TO FIRE 9d MULTI -SERVICE POKE THRU TELECOM CONNECTOR TYPES AS INDICATED BY TELECOMMUNICATIONS SYMBOLS. FLOOR BOX BY E.C. FLOOR BOX TELECOM RATED SYMBOL WIREMOLD - EHWB8, 8 GANG LOCKING WALLBOX REFER TO © REFER TO ARCHITECTURAL DRAWINGS IN WALL N/A QUAD NOTE ul (AT CMU WALLS INSTALL AT 2'-2 3W OR SEE ARCHITECTURAL ELEVATION. RECEPTACLE W, 2-X AT GYPSUM WALL TYPE INSTALL AT Z-0") TELECOMMUNICATIONS WORK AREA OUTLET SYMBOLS WORK AREA OUTLETS AND CABLING SYMBOL DESCRIPTION TYPICAL LOCATION TYPICAL FACEPLATE 120 VAC POWER BY E.C. NOTES DX - DATA AND / OR VolP WORK AREA OUTLET: RJ45, CATEGORY CABLING AS SPECIFIED, (8P, 8C) CONNECTOR FOR DATA CABLED TO THE APPLICABLE DATA AND / OR VolP 18" AFF ONE DUPLEX REFER TO 01135 RIA5 DX DATA PATCH PANEL IN THE NEAREST WIRE CENTER, VOICE JACKS CROSS CONNECTED TO VOICE TERMINAL PANEL. OR AS SINGLE RECEPTACLE NOTE 55 C X=NUMBER OF - (1, 2, 3, 4, 5, 6) . NOTED. GANG FOR EVERY (2) G,L S R� -am =DENOTES ABOVE MILLWORK REFER TO JACK 3X MAX LABEL -a = DENOTES TO INSTALL HORIZONTALLY ON MILLWORK APRON ARCH DWGS. "A", "B", "C", "DSS", "E", "F", "M", "PAW" DENOTES TYPE OF PHONE HANDSET. v W W - WALL TELEPHONE OUTLET: ONE (1) RJ-45, CATEGORY CABLE AS SPECIFIED, (8P, 8C) CONNECTOR FOR VOICE CABLED TO THE VOICE PATCH PANEL IN THE 48" AFF OR AS SINGLE REFER TO NEAREST WIRE CENTER AND CROSS CONNECTED TO VOICE TERMINATION PANEL. NOTED. REFER T GANG NONE NOTE C "C", "PAW' DENOTES TYPE OF PHONE HANDSET. ARCH DWGS. G,L TELEPHONE OUTLET: 18" AFF OR AS REFER TO . ONE (1) RJ-45, CATEGORY CABLE AS SPECIFIED, (8P, 8C) CONNECTOR FOR VOICE CABLED TO THE VOICE PATCH PANEL IN THE NOTED. REFER SINGLE NONE NOTE ® C NEAREST WIRE CENTER AND CROSS CONNECTED TO VOICE TERMINATION PANEL. TO GANG G,L " T", "E" " "PAWTENOTES TYPE OF PHONE ARCH DWGS. TELEPHONE INSTRUMENT TYPES "A" INDICATES AN 18-BUTTON OR MORE MULTI -LINE DIGITAL LCD SPEAKERPHONE HANDSET, (N.I.C.) FOR REFERENCE ONLY. "B" - INDICATES A 12-BUTTON MULTI -LINE DIGITAL LCD SPEAKERPHONE HANDSET, (N.I.C.) FOR REFERENCE ONLY. "G, - INDICATES A SINGLE LINE APPEARANCE VoIP LCD SPEAKERPHONE HANDSET, (N.I.C.) FOR REFERENCE ONLY. (DSS) INDICATES ADSS/BLF (DIRECT SELECTION STATION/BUSY LAMP FIELD) OR VOICE SYSTEM CONSOLE, (N.I.C.) FOR REFERENCE ONLY. "E" - DEDICATED EMERGENCY ELEVATOR LINE "F" - DEDICATED FAX LINE "M" - DEDICATED MODEM LINE "PAW" - DEDICATED PUBLIC ADDRESS WALL TELEPHONE OUTLET TECHNOLOGY COMMUNICATIONS GENERAL NOTES (NOTE: APPLIES TO ALL TECHNOLOGY DRAWINGS) 1. TECHNOLOGY CONTRACTOR = THE ASSOCIATED/AWARDED CONTRACTOR RESPONSIBLE FOR PROVIDING THE APPLICABLE REFERENCED SYSTEM. 2. APPLIES TO ALL TECHNOLOGY DIVISION 27 AND 28 SYSTEMS - CONTRACTORS HAVE THE RESPONSIBILITY TO SURVEY AND FIELD VERIFY SYSTEMS EQUIPMENT AND DEVICES, AND PROVIDE THE NECESSARY EQUIPMENT AND QUANTITIES (NEW, EXIST iNG, RELOCA I ED) 1 I EI'V15, T 0 PROVIDE FULLY FUNCTIONAL SYSTEMS AS DELINEATED IN THE SPECIFICATIONS AND DRAWINGS FOR THIS PROJECT. ALL REFERENCE TO BACKBOXES, BUILDING PREPARATION, POWER REQUIREMENTS IS FOR REFERENCE PURPOSES ONLY. REFER TO DIVISION 26 ELECTRICAL FOR COORDINATION REQUIREMENTS. 3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN THE CONTRACT. COORDINATE LOCATIONS OF ALL EQUIPMENT WITH OTHER TRADES BEFORE STARTING CONSTRUCTION. 4. SEE ELECTRICAL AND TECHNOLOGY DRAWINGS FOR FLOOR PLANS, DIAGRAMS AND DETAILS PERTAINING TO THIS PROJECT. 5. COORDINATE WITH CONSTRUCTION MANAGER, OTHER TRADES AND THE OWNER DURING ALL PHASES. ALL COMMUNICATIONS, SYSTEMS, DEVICES MUST BE MAINTAINED AT ALL TIMES UNLESS PHASING REQUIRES OTHERWISE. INTERRUPTIONS AND SHUTDOWNS SHALL BE SCHEDULED IN ADVANCE AND APPROVED FOR TIME TO COMPLETE WORK. TAG ALL CABLES TO REMAIN DURING ALL PHASES TO PROPERLY KEEP THE ALL COMMUNICATION SYSTEMS ACTIVE. UPON COMPLETION OF CONSTRUCTION, ALL CABLES THAT ARE NOT ACTIVE OR TAGGED TO REMAIN FOR FUTURE USE, SHALL BE REMOVED END TO END AS PER THE NEC. 6. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AT THE PROPER LOCATIONS ALL BUILDING PREPARATION AND CABLE PATHWAYS INCLUDING BUT NOT LIMITED TO CONDUIT, SLEEVES, NYLON PULL STRINGS, STANDARD BACKBOXES, RING PLATES, INSULATING BUSHINGS, FLOOR BOXES, CABLE TRAY, LADDER RACK AND ALL VAC POWER. REQUIREMENTS. ALL DESCRIPTIONS AND NOTES ON THE TECHNOLOGY DRAWINGS AND SPECIFICATIONS RELATING TO ELECTRICAL ITEMS ARE FOR REFERENCE PURPOSES ONLY. REFER TO ELECTRICAL ENGINEERS DIVISION 26 DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL DETAILS AND REQUIREMENTS. 7. BEFORE ANY CONSTRUCTION CAN BEGIN IN ANY COMMUNICATION EQUIPMENT ROOM, THE CONTRACTOR SHALL COORDINATE LAYOUT LOCATIONS AND CLEARANCES OF ALL EQUIPMENT WITH THE OWNERS REPRESENTATIVE TO APPROVE THE INSTALLATION AND ANY FUTURE SPACE. 8. REFER TO THE ARCHITECTURAL DRAWING FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF EQUIPMENT. ALL SUCH EQUIPMENT AND COLORS SHALL BE COORDINATED WITH THE ARCHITECT. CONTACT ARCHITECT FOR CLARIFICATION OF MOUNTING REQUIREMENTS, ARCHITECTURAL HEIGHTS, AND DIMENSIONS SUPERSEDE THOSE ON THESE DRAWINGS. 9. COORDINATE AND REFER TO REFLECTIVE CEILING PLAN FOR FLUSH MOUNTED CEILING DEVICES. 10. PROVIDE MINIMUM'/4" A/C QUALITY, VOID FREE, FIRE RATED PLYWOOD BACKBOARDS ON ALL WALLS, MOUNTED 12" AFF, PAINT ALL SIDES WITH TWO COATS OF MATTE GREY (OR COORDINATE COLOR WITH ARCHITECT) FIRE RETARDANT PAINT IN ALL COMMUNICATION EQUIPMENT MOUNTING LOCATIONS. 11. PROVIDE SEPARATION BETWEEN RACEWAY, CABLES AND OTHER; SOURCES OF (EMI) PER ANSIITIA-569-A AND ADDENDUMS. 12. ELBOW RADIUS FOR RACEWAYS SMALLER THAN 2" TO BE (6) TIMES THE RACEWAY DIAMETER. ELBOW RADIUS FOR CONDUITS 2" OR LARGER TO BE (10) TIMES THE RACEWAY DIAMETER. 13. ALL EMPTY RACEWAYS SHALL BE PROVIDED WITH A PLENUM RAPED, NYLON PULL STRING. 14. BLANK STAINLESS -STEEL FACEPLATE SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR AT ALL OPEN BACKBOXES. 15. COORDINATE PROPER METHODS FOR PENETRATIONS WITH FIRE STOPPING AS REQUIRED, THROUGH FIRE/SMOKE RATED CONSTRUCTION PER DIVISION 07 8413 SPECIFICATIONS. PROVIDED BY CABLING INSTALLER. 16. CONDUITS AND CABLING FROM STREET TO SERVICE ENTRANCE/IDEMARCATION SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR PER SITE UTILITY DRAWINGS, TECHNOLOGY/ELECTRICAL POWER DRAWINGS AND DIVISION 26 SPECIFICATIONS. COORDINATE LOCATION OF DEMARCATION POINT. 17. LADDER RACKS, CONDUITS, D-RINGS, ETC. FOR CABLE SUPPORT IN ANY MDF OR OF SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR PER TECHNOLOGY DOCUMENTS AND DIVISION 26 SPECIFICATIONS. 18. CABLE TRAYS, CONDUITS, SLEEVES AND J-HOOKS FOR FIBER BACKBONE CABLING AND OTHER BACKBONE CABLING SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR PER DIVISION 26 SPECIFICATIONS. 19. CABLE TRAY, SURFACE MOUNTED RACEWAYS, CONDUITS, SLEEVES AND J-HOOKS FOR HORIZONTAL CABLING FROM MDF AND OF TO THE WORK AREA OUTLETS/CONNECTORS SHALL BE PROVIDED PER DIVISION 26 SPECIFICATIONS. 20. COORDINATE OUTLET INSTALLATIONS, WALL (RECESSED OR SURFACE), CEILING, FLOOR; SLEEVE OR IN -FLOOR SYSTEM, UTILITY COLUMN, PER TECHNOLOGY AND ELECTRICAL POWER DRAWINGS AND DIVISION 26 SPECIFICATIONS. 21. TECHNOLOGY CONTRACTOR TO ENSURE ALL SLEEVES (LESS THAN 4 FEET) SHALL BE MAXIMUM 60% FILL FOR ALL CABLING AND MAXIMUM 40% FILL FOR ALL CONDUITS AND RACEWAYS. 22. PROVIDE (2) 2" CONDUIT SLEEVES ABOVE ENTRY DOORS TO ALL ROOMS REQUIRING TELECOMMUNICATION. 23. CONDUIT SECTIONS SHALL BE NO LONGER THAN 90'. CONDUIT RUNS LONGER THAN 90' WILL REQUIRE A PULL BOX AT 90' MAXIMUM INTERVALS. CONDUIT RUNS CONTAINING MORE THAN TWO NINETY DEGREE BENDS SHALL REQUIRE A PULL BOX. ALL OFFSETS SHALL BE RATED AS EQUIVALENT TO A NINETY -DEGREE BEND. 24. REGARDLESS OF PATHWAY TYPE, ALL CABLING SHALL BE SUPPORTED AT 64' MAXIMUM INTERVALS. 25. UNLESS OTHERWISE NOTED, CABLE PATHWAYS WITHIN ROOMS SHALL RUN PARALLEL TO WALLS. 26. ELECTRICAL CONTRACTOR SHALL PROVIDE PROPER BONDING AND GROUNDING OF HORIZONTAL PATHWAYS IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES AND STANDARDS. 27. UNLESS OTHERWISE NOTED, ALL CONDUITS SHALL BE A MINIMUM 3/4 ". 28. ALL BACKBOX CONDUITS SHALL BE ROUTED TO NEAREST ACCESSIBLE CEILING SPACE WHETHER OR NOT SHOWN AS SUCH. 29. IT IS NOT THE INTENTION TO SHOW EVERY DETAIL, FITTING, HANGER, PATHWAY OR DEVICE. ALL SUCH ITEMS SHALL BE FURNISHED AND INSTALLED AS NECESSARY FOR A COMPLETELY OPERATIONAL SYSTEM. 30. ALL FIBER BACKBONE CABLING SHALL BE ARMORED CABLING PROVIDED BY TECHNOLOGY CONTRACTOR. 31. CONTRACTORS SHALL NOT RUN ANY CABLING OR PATHWAYS THROUGH ELEVATOR SHAFTS, ELEVATOR MACHINE ROOM AND STAIRWELL ENCLOSURES UNLESS CABLING OR PATHWAY SYSTEMS SERVE THE SPACE. 32. ALL LOW VOLTAGE CABLING SHALL BE AT LEAST 12" AWAY FROM ANY POWER WIRING TECHNOLOGY COMMUNICATIONS NOTES A. DEVICE PROVIDED BY APPLICABLE TECHNOLOGY CONTRACTOR; TECHNOLOGY CONTRACTOR = THE ASSOCIATED/AWARDED CONTRACTOR RESPONSIBLE FOR PROVIDING THE APPLICABLE REFERENCED SYSTEM. B. DEVICE PROVIDED BY DOOR HARDWARE CONTRACTOR. C. DEVICE PROVIDED BY OTHERS. D. CABLING PROVIDED AND TERMINATED BY TECHNOLOGY CONTRACTOR. E. CABLING PROVIDED AND TERMINATED BY ELECTRICAL CONTRACTOR. F. CABLING PROVIDED AND TERMINATED BY ELEVATOR CONTRACTOR. G. CABLING AND OUTLET PROVIDED BY DIVISION 27 TELECOMMUNICATIONS CONTRACTOR. H. CABLING BETWEEN DEVICE (CARD READER, KEYPAD, ELECTRONIC LOCK, REQUEST -TO -EXIT, ELECTRONIC HINGE, POWER TRANSFER, DOOR SWITCHES) AND DOOR JUNCTION BOX PROVIDED AND TERMINATED BY ELECTRICAL CONTRACTOR. I. CABLING BETWEEN DOOR JUNCTION BOX AND SYSTEM HEADEND PROVIDED AND TERMINATED BY TECHNOLOGY CONTRACTOR. J. SPECIALTY BACKBOX AND/OR ASSEMBLY - FURNISHED BY TECHNOLOGY CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR. CONDUIT, PULL STRING, PATHWAYS TO ACCESSIBLE LOCATION PROVIDED BY ELECTRICAL CONTRACTOR. K. INDUSTRY STANDARD BACKBOX'S PROVIDED BY ELECTRICAL CONTRACTOR. CONDUIT, PULL STRING, PATHWAYS, APPLICABLE RING PLATE TO ACCESSIBLE LOCATION PROVIDED BY ELECTRICAL CONTRACTOR. L. THE STANDARD BACKBOX FOR LOW VOLTAGE DEVICES, UNLESS OTHERWISE NOTED, SHALL BE A STANDARD 411/16" WIDE x 4/ 11/16 HIGH X 3'/4" DEEP BOX WITH APPLICABLE 1-GANG OR 2-GANG RING PLATE TO ACCOMMODATE THE APPLICABLE FACEPLATE AS REQUIRED PER THE DEVICE'S DESCRIPTION, PROVIDED BY ELECTRICAL CONTRACTOR. M. INTERFACE TO DEVICES AND CABLING PROVIDED BY TECHNOLOGY CONTRACTOR. N. SYSTEM HEADEND PROVIDED BY TECHNOLOGY CONTRACTOR. 0. SYSTEM HEADEND PROVIDED BY OTHERS. P. INTERFACE TO SYSTEM HEADEND PROVIDED BY TECHNOLOGY CONTRACTOR. Q. SEE SPECIFICATIONS FOR SYSTEM HEADEND REQUIREMENTS. R. HEADEND EQUIPMENT AND FIELD DEVICES SHALL BE PROVIDED BY OTHERS UNDER A SEPARATE CONTRACT. S. HEADEND EQUIPMENT, CABLING AND FIELD DEVICES SHALL BE PROVIDED BY OTHERS UNDER A SEPARATE CONTRACT. T. BLANK STAINLESS -STEEL FACEPLATE SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR AT ALL OPEN BACKBOXES. U. NOT USED. V. NOT USED. W. PROVIDED BY ELECTRICAL CONTRACTOR X. THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE REQUIRED 120VAC DUPLEX OUTLET FOR THIS DEVICE. Y. THE ELECTRICAL CONTRACTOR SHALL PROVIDE A HARDWIRED 12'.OVAC QUAD OUTLET ON A 20AMP DEDICATED CIRCUIT WITHIN THE APPLICABLE RACK/CABINET/HEADEND FOR THIS DEVICE. IT IS RECOMMENDED THAT CIRCUIT BE ON EMERGENCY GENERATOR POWER. Z. DEVICE DOES NOT REQUIRE BACKBOX. APPLIES TO ALL SYSTEMS: THE CONTRACTOR HAS THE RESPONSIBILITY TO SURVEY AND FIELD VERIFY EXISTING SYSTEMS EQUIPMENT AND PROVIDE THE NECESSARY QUANTITIES OF NEW AND/OR RELOCATED ITEMS TO MAKE FULLY FUNCTIONING SYSTEM(S) AS DELINEATED IN THE SPECIFICATIONS AND/OR DRAWINGS ASSOCIATED WITH THE PROJECT. ALL REFERENCE AND SPECIFICATIONS OF WALLBOXES, BACKBOX AND ALL ELECTRICAL SPECIFICATIONS IT IS FOR REFERENCE ONLY, REFER TO ELECTRICAL DRAWINGS AND DIV. 26 FOR COORDINATION. "CONFORMITY AND COMPATIBILITY" PREVENT INCOMPATIBILITY BETWEEN ANY OF THE COMPONENTS FOR THEIR PROPER OPERATION AND ANTICIPATED REQUIRED FUNCTION OF THE FINISH PRODUCT, WHETHER SPECIFIED AND/OR AS AN APPROVED EQUAL PRODUCT, THE TECHNOLOGY CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ASSURED CONFORMITY OF ALL OPERATING SYSTEMS TO THE TECHNOLOGY CONSULTANT/ENGINEER PRIOR TO THE PURCHASE AND/OR INSTALLATION OF ALL EQUIPMENT. " GENERAL NOTE. ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT 7-0 SCALE (N.T.S.). THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. APPROPRIATE MODIFICATION MAYBE REQUIRED TO ENSURE SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. DIV 26 ELECTRICAL COORDINATION NOTES 1. DEVICES. WIRING. EQUIPMENT. CONNECTIONS, BOXES. CONDUIT AND OTHER ITEMS RELATED TO THE BUILDING'S TECHNOLOGY. COMMUNICATIONS AND AUDIOVISUAL SYSTEMS ARE INDICATED IN TECHNOLOGY SERIES DRAWINGS AND DIVISION 27 SPECIFICATIONS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE INSTALLATION OF THESE DEVICES WITH THE DIVISION 27 DRAWINGS AND SPECIFICATIONS, REFER TO DIVISION 26 SPECIFICATIONS AND GENERAL DIVISION 01 SPECIFICATIONS FOR SCOPE OF WORK UNDER THIS CONTRACT. 2. DEVICES. WIRING. EQUIPMENT. CONNECTIONS, BOXES. CONDUIT AND OTHER ITEMS RELATED TO THE BUILDING'S SECURITY SYSTEMS ARE INDICATED IN SECURITY SERIES DRAWINGS AND DIVISION 28 SPECIFICATIONS. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE INSTALLATION OF THESE DEVICES WITH THE DIVISION 28 DRAWINGS AND SPECIFICATIONS. REFER TO DIVISION 26 SPECIFICATIONS AND GENERAL DIVISION 01 SPECIFICATIONS FOR SCOPE OF WORK UNDER THIS CONTRACT, 3. THE ELECTRICAL CONTRACTOR FOR THE PROJECT SHALL FURNISH AND INSTALL REQUIRED 120 VAC ELECTRICAL RECEPTACLES AND PATHWAYS INCLUDING CONDUIT, SLEEVES, BUSHINGS. BACK BOXES, PULL LINES. BLANK FACEPLATES WHERE REQUIRED. CABLE TRAY. AND PLYWOOD BACKBOARDS FOR TERMINATION FIELDS, 4. GENERAL INSTALLATION REQUIREMENTS FOR CONDUIT AND BACKBOXES ARE INDICATED IN DIVISION 26 SPECIFICATIONS AND ON ELECTRICAL SERIES DRAWINGS. 5. ELECTRICAL CONTRACTOR SHALL PROVIDE 120 VAC POWER AT EACH ACCESS CONTROLLED DOOR INDICATED ON PLANS. ELECTRICAL CONTRACTOR SHALL ALSO PROVIDE CONDUIT TO DEVICES AT EACH ACCESS CONTROLLED DOOR AS INDICATED IN SECURITY SYSTEMS DETAILS. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUCTS AND PATHWAYS FOR THE BUILDING TECHNOLOGY SYSTEMS SPECIFIED ON THE T SERIES DRAWINGS. THIS SHALL INCLUDE MAIN CONDUIT TRUNKS FOR BACKBONE CABLING (IF APPLICABLE). AND ALL REQUIRED SLEEVES AND SEALS. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE COMPLETE GROUNDING AND BONDING SYSTEM FOR TELECOMMUNICATIONS ROOMS AS INDICATED ON THE T* SERIES DRAWINGS. INCLUDE BONDING TO MAIN BUILDING ELECTRICAL SERVICE AS NOTED IN THE ELECTRICAL DETAILS. CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0088 N PHASE 1 OF 4 J w - m R l •° 8 9 Moody Road Building D Suite 18 Q Enfield, CT 06082 ti T.860-341-1206 Q F.860-239-1358 c www.gtc.US.com N C Bicsi aul: JOSEMi J NORTON REG- Na. 202538R Expm -12-3 - SIGNATURE moser piton nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE GENERAL SHEET TECHNOLOGY DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects is .n E z U O n z IL 2 DWG. NO. f1111111 L E z U 'o n z 0- VIDEO F- CC MANAGEMENT zz 0 SYSTEM F- F- w z z G j— O o 20" FLAT z PANEL MONITOR KEYBOARD \, STRIP TO RACK POWER TYPICAL SURVEILLANCE ENCLOSED CABINET FOPP SWITCH BY MHIS PATCH PANEL PATCH I PANEL I TYPICAL FREE STANDING RACK ASSEMBLY ELECTRONIC SAFETY & SECURITY RISER N.T.S. cli rV 2ND FLOOR CCTV �] 1ST FLOOR VIDEO PRESENTATION OUTLETS OUTLETS DESCRIBED AS FUTURE AND SHOWN ON DRAWINGS ARE FOR COORDINATION PURPOSES. CABLING AND EQUIPMENT N.I.C. (UNDER SEPARATE CONTRACT SYMBOL DESCRIPTION TYPICAL TYPICAL 120 VAC NOTES LUCA I TUN FACEPLATE POWER BY E.C. PDC - PANEL DISPLAY CONNECTION OUTLET: (BASIS OF DESIGN IS LEGRAND EVOLUTION SERIES 4 GANG WALL BOX OR EQUAL) IN WALL ENCLOSURE WITH MULTIPLE DEVICE MOUNTING OPTIONS WITH INTEGRATED CABLE MANAGEMENT AND POWER KIT PDC TWO (2) RJ-45, CATEGORY CABLE AS SPECIFIED(8P, 8C) CONNECTOR, DATA CABLED TO DATA PATCH PANEL IN THE NEAREST WIRE CENTER REFER TO SEE PATHWAYS BY ELECTRICAL CONTRACTOR (FOR FUTURE CABLING FOR VGA, AUDIO, USB, HDMI, ETC) ARCH. REFER TO DATA =NOTE G ALL AUDIO / VIDEO CABLING FOR THE PANEL DISPLAY CONNECTION IS PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) ELEVATION SPECIAL NOTE X BACKBOX = COVER PROVIDED BY ELECTRICAL CONTRACTOR DWGS. NOTE W, X DSP - DIGITAL SIGNAGE PANEL CONNECTION OUTLET: (BASIS OF DESIGN IS LEGRAND EVOLUTION SERIES 4 GANG WALL BOX OR EQUAL) IIV VVALL ENCLOSURE WITH MULTIPLE DEVICE MOUNTING OPTIONS WITH INTEGRATED CABLE MANAGEMENT AND POWER KIT REFER TO SEE DSP TWO (2) RJ45, CATEGORY CABLE AS SPECIFIED(8P, 8C) CONNECTOR, DATA CABLED TO DATA PATCH PANEL IN THE NEAREST WIRE CENTER PATHWAYS BY ELECTRICAL CONTRACTOR (FOR FUTURE CABLING FOR VGA, AUDIO, USB, HDMI, ETC) ARCH. REFER TO DATA =NOTE G ALL AUDIO / VIDEO CABLING FOR THE PANEL DISPLAY CONNECTION IS PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) ELEVATION SPECIAL NOTE X BACKBOX = COVER PROVIDED BY ELECTRICAL CONTRACTOR DWGS. N NOTE NOTE W, X FIWB - FUTURE INTERACTIVE WHITE BOARD: INDICATES LOCATION FOR COORDINATION ONLY FIWB (NIC) PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) REFER TO ARCH. REFER FPD - FUTURE PANEL DISPLAY: INDICATES LOCATION FOR COORDINATION ONLY DRAWINGS N/A NONE TO NOTE (NIC) c FPD NIC PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) IN LINE WITH C BAR / TR = hAAPVPP Rr1ARll ANTI TA(K Rr)APIl MB/TB FVPO FVPO - FUTURE VIDEO PROJECTION OUTLET LOCATION: ABOVE CEILING THREE REFER REFER TO ® (2) 1 1/4" CONDUIT TO ASSOCIATED FVPS OUTLET. PROVIDE BLANK COVERS PLATING OR AS NOTED GANG NOTE X X NOTE FUTURE CABLING PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) ON DWGS. BACKBOX W X FVPS FVPS - FUTURE VIDEO PRESENTATION SOURCE OUTLET: 18" AFF UK AS DOUBLE RFFFR T(1 ® (2)1 1/4" CONDUITS TO ASSOCIATED FVPO OR PDC OUTLET. PROVIDE BLANK COVERS PLATING NOTED ON GANG QUAD NOTE FUTURE CABLING PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) DWGS. BACKBOX RECEPTACLE L, W, 2-X ONE QUAD ID 1D FLVP - FUTURE LOW VIDEO PRESENTATION OUTLET: RECEPTACLE 18" A.F.F. OR NONE IF REFER TO FLVP (2)1 1/4" CONDUITS TO ASSOCIATED "CVP" OR "PDC" OUTLET. SEE DOUBLE LOCATED NOTE FUTURE CABLING PROVIDED BY OTHERS UNDER SEPARATE CONTRACT (NIC) ARCHITECT GANG ADJACENT TO L, W, 2-X DWGS TEACHER QUAD PROVIDE BLANK INSERTS RECEPTACLE - CEILING VIDEO PROJECTOR OUTLET: mCVP ONE (1) RJ-45, CATEGORY CABLE AS SPECIFIED, (8P, 8C) CONNECTOR FOR DATA CABLED TO PATCH PANEL IN THE NEAREST WIRE ABOVE DOUBLE REFER TO REFER TO CENTER. CEILING GANG NOTE X NOTE PATHWAYS FOR FUTURE CABLING AND PRESENTATION OUTLET TO "FLVP" SEE DETAIL L, W, X PROVIDE BLANK INSERTS WIRELESS ACCESS POINT SYMBOLS SYMBOL DESCRIPTION TYPICAL TYPICAL 120 VAC NOTES LOCATION FACEPLATE POWER BY E.C. LABEL IN CEILING OR WALL In mr vvr,r VVMr VVIF-W I CQQ AfY'CQQ Dr\IAIT nATA U ITT CT• vvnr - vv1RLL.cJJ r\\.uwJ rvuv 1 ur-1I n vU I LL I . MOUNTED 96° SINGLE nr_r_r_n T R�rr=R IV X = DENOTES INSTALLED ABOVE CEILING OR WALL. AFF NONE NOTE X TWO (2) RJ-45, CATEGORY CABLE AS SPECIFIED, (8P, 8C) CONNECTOR FOR DATA CABLED TO DATA PATCH PANEL IN THE NEAREST WIRE REFER TO GANG G, L. CENTER. PROVIDE A 20'-0" DATA PATCH CABLE TO INTERFACE WITH FUTURE DEVICE/ANTENNA. DWGS. FOR LABEL LOCATIONS. IN CEILING WAP = MODULAR PLUG TERMINATED LINK ("MPTL") DATA OUTLET: OR WALL TWO (2) RJ-45, CATEGORY CABLE AS SPECIFIED (8P, 8C) CONNECTOR, FOR DATA CABLED TO DATA PATCH PANEL IN THE NEAREST WIRE MOUNTED 96" REFER TO WAP CENTER. PROVIDE TWENTY (20) FEET LOOP AT THE DEVICE SIDE AND A "MPTL" TERMINATION, HORIZONTAL CABLE DIRECTLY CONNECTED AFF NONE NONE NOTE G di77 TO TWI= nl=\/II= r'r)r1Dr)IKIATC I fVATIMIQ NITI-I WAD CVQTI=hh IVAITDA(`T(1D AAIr) AD-ITG(T REFPENCTALIATIONI IP IMP AKIV PPAW)KI IVTLVViVL,VVV1VII CI LVw-1V 111111 Y- VV1-VY 11--1-1\/--1w1--IOI`v�..1-I-I 1r PFFFP T(1 CONRACTOR COULD NOT USE "MPTL" REVERT TO TERMINATION IN A BACKBOX AND PLATE AS ABOVE SYMBOL. DWGS. FOR LOCATIONS. WE WE - WALL ENCLOSURE FOR WIRELESS ACCESS POINT, NONMETALLIC: WIREMOLD #NMAPME OR EQUAL. WALL MOUNTED IN CEILING OR WALL REFER TO P I (CKV4DI C EI IC OS IDC DD(V /IrNED DV TCI CC,01'AAAI IAII(1ATIIIAIC (V1KITDAr1TnD Tn UnI ICC DDCCCAITICI ITI IDC 1AIIDCI CCC ArY`CCC MOOT LVUf\HDLG CIVULVJVRC rRV V IVGV D I I CLCUVIVIIVIU1VI U/:l IUIVJ U\J1V I F\Ml1 VR I U I IVUJL r1\LJL1V Ill U I UI\L MIM-1.L-JJ 11VVLJJ rUI Ill I MOUNTED 96" AFF SPECIAL NONE NOTES DEVICE. INSTALL ENCLOSURE OVER WIRELESS ACCESS POINT (WAP) OUTLET. WIRELESS ACCESS POINT DEVICE PROVIDED BY OTHERS REFER TO G. WP = WEATHER PROOF ENCLOSURE ARCH. DWGSTOR HEIGHT. ACCESS CONTROL 1. VANDAL -RESISTANT PROXIMITY CARD READERS SEE DRAWINGS FOR LOCATIONS. 2. MDF SHALL HOUSED THE S2 HEAD END EQUIPMENT. 3. EXTERIOR DOORS, PROVIDE DOUBLE -THROW DOUBLE -POLE DOOR CONTACTS SEE SPECIFICATIONS. 4. THE REX AT THESE LOCATIONS SHOULD BE CONNECTED ONLY TO THE DOOR STATUS CONTACT ON THE DOOR, AND NOT UNLOCK THE DOOR FROM THE INSIDE, IN ORDER TO LOG THE EVENT IN THE ACCESS SYSTEM AS "FREE EXIT GRANTED". IF THE DOOR IS NOT COMPLETELY CLOSED, THE ACCESS SYSTEM WILL RECEIVE A "PROPPED" CONDITION AND REPORT VIA EMAIL OR SMS TEXT TO ON SITE SECURITY PERSONNEL. IF THE DOOR IS FORCED OPEN FROM THE OUTSIDE DURING THE DAY WHEN THE INTRUSION SYSTEM IS OFF, THE ACCESS SYSTEM WILL RECEIVE A FORCED CONDITION AND ALSO ALERT ON SITE SECURITY PERSONNEL. 5. COORDINATE CARD READER LOCATIONS AT ELEVATORS WITH ELEVATOR CONTRACTOR. 6. COORDINATE WITH SCHOOL PERSONNEL TO DETERMINE PROGRAMMING REQUIREMENTS FOR SCHEDULING AND MANAGEMENT OF EXTERIOR DOORS. 7. CONTRACTOR TO PROVIDE 100 KEY FOBS, DIGITAL CAMERA, AND BADGE PRINTER SEE SPECIFICATIONS. CCTV 1. CAMERA SYMBOLS THAT ARE SHOWING CRISSCROSS IN DRAWINGS ARE DIAGRAMMATICALLY PLACE IN DRAWINGS, CONTRACTOR IS RESPONSIBLE TO PLACE ABOUT 72" APART SO THE FIELD OF VIEW ARE TO BE CRISSCROSSED NOT SHOW A BLANK COVERAGE. 2. INSTALL CAMERAS AS INDICATED ON THE DRAWING, HOWEVER PLACEMENT MAY BE ADJUSTED AS NEEDED TO AVOID OBSTRUCTIONS (I.E. EXIT SIGNS, ETC) AND TO MAXIMIZE THE FIELD OF VIEW. 3. PROVIDE MOUNTS, HOUSINGS, AND OTHER ACCESSORIES AS NEEDED FOR A FULLY FUNCTIONING SYSTEM. 4. DATA CABLE IS THE RESPONSIBILITY OF THE TELECOM CONTRACTOR, COORDINATE CATEGORY DATA CONNECTION WITH SUCH CONTRACTOR. 5. IN THE MAIN OFFICE, VIDEO SIGNAL FOR THE TWO MONITORS MAY BE FED FROM THE SAME SOURCE PC. PROVIDE VGA OR HDMI SPUTTER AND ALL CABLING BETWEEN SOURCE PC AND BOTH MONITORS (IF APPLICABLE). 6. VMS SOFTWARE, EACH CAMERA IS TO HAVE AN UNDERSTANDABLE DESCRIPTION ASSIGNED TO EACH CAMERA DESCRIBING ITS LOCATION AND VIEWING AREA (I.E. FL 2 CORR. VIEWING EAST, ETC). 7. CCTV CAMERA TO INCLUDE IR ILLUMINATION. PROVIDE AUDIBLE SIREN ON EXTERIOR WALL OF OUTDOOR STORAGE, WITH PROGRAMMING TO SILENCE THE SIREN AFTER 5 MINUTES INTRUSION DETECTION 1. PROGRAMMING OF INTRUSION DETECTION SYSTEM TO INCLUDE SEPARATE ZONES FOR LIBRARY, AUDITORIUM, SCHOOL, AND OUTDOOR STORAGE AREAS, WITH THE ABILITY TO ARM DISARM THE ENTIRE BUILDING. KEYPAD WILL BE STRATEGICALLY LOCATED, DATA CABLE IS THE RESPONSIBILITY OF THE TELECOM CONTRACTOR, COORDINATE CATEGORY DATA CONNECTION WITH SUCH CONTRACTOR. 2. ALL SYSTEM TESTING TO BE COORDINATED WITH SECURITY INTERGRATORS AND THE DISTRIC SECURITY DIRECTOR, AND SCHOOL STAFF. PANIC BUTTONS 1. PANIC BUTTONS WILL BE INSTALLED AT THE LOCATIONS INDICATED. COORDINATE EXACT PLACEMENT WITH OWNER (I.E. ON WALL, UNDER DESK, ETC). 2. IN THE EVENT OF ACTIVATION, THE INTRUSION DETECTION SYSTEM SHALL NOTIFY THE POLICE OR MONITORING COMPANY, AS WELL AS BROADCAST A PRE- RECORDED MESSAGE VIA THE MASS NOTIFICATION SYSTEM. 3. SECURITY CONTRACTOR TO PROVIDE WIRING AND RELAY PROGRAMMING FROM THE INTRUSION DETECTION PANEL TO THE FIRE ALARM PANEL TO TRIGGER PRE- RECORDED MESSAGE COORDINATE ALL WORK WITH FIRE ALARM CONTRACTOR. VIDEO INTERCOM 1. PROVIDE SEPARATE INTERCOM SYSTEMS FOR VESTIBULE SCHOOL ENTRANCES. FIRST FLOOR SECURITY DESK TO CONTROL DOOR AT VESTIBULE. MASTER STATIONS IN ADMIN/ RECEPTION OFFICE TO CONTROL SCHOOL ENTRANCE DOORS. SECURITY CONTRACTOR RESPONSIBLE FOR INTERFACING AND PROVIDING ALL RELAYS AND WIRING TO CONTROL DOOR HARDWARE. ADDITIONAL INFORMATION 1. IP ADDRESSES AND OTHER NETWORK CONFIGURATION INFORMATION TO BE PROVIDED BY OWNER'S IT DEPARTMENT. REQUEST FOR NETWORK ADDRESSES SHALL INCLUDE THE NUMBER OF ADDRESSES NEEDED FOR EACH SYSTEM (I.E. CCTV, ACCESS CONTROL, INTRUSION, ETC) AND A DESCRIPTION OF WHAT EACH WILL BE USED FOR (I.E. CCTV CAMERA, SERVER, DOOR CONTROLLER PANEL, ETC). REQUEST TO BE SUBMITTED TO THESCHOOL IT DEPARTMENT AT LEAST THREE WEEKS PRIOR TO DATE WHEN ADDRESSES WILL BE NEEDED FOR CONFIGURATION AND TESTING. 2. SERVER AND/OR PC HARDWARE FOR SECURITY SYSTEMS WILL BE PROVIDED BY SURVEILLANCE CONTRACTOR. 3. CAMERA POSITIONING TO BE COORDINATED WITH DISTRICT OR SCHOOL SECURITY DEPARTMENT. ALL CAMERA LOCATIONS AND FIELDS OF VIEW MUST BE REVIEWED AND APPROVED BY THE SCHOOL OR DISTRICT SECURITY DEPARTMENT, 4. TELCOM CONTRACTOR TO PROVIDE CATEGORY UTP CABLING TO IF CAMERA'S AND OTHER IP BASED SECURITY EQUIPMENT. COORDINATE INSTALLATION WITH TELCOM CONTRACTOR. 5. ALL SECURITY CABLING TO BE PLENUM RATED. 6. ALL SECURITY EQUIPMENT (ALARM PANELS, DOOR CONTROLLERS, ETC) TO BE LOCATED IN MDF/IDF ROOMS ON PLYWOOD BACKBOARD. TYP. MDF TYPICAL MDF/IDF ROOF UPPER LEVEL INTRUST N ALARM CONTRO OOR FCCES ONTR DOOR ACCES S CONTR DOOR ACCES S CONTR MAIN LEVEL LOWER LEVEL P/S PNS L ( I PNS L P S ANEL D2 GENERAL NOTES - SECURITY SYSTEM �Q 1. ALL WIRING SHALL BE PLENUM RATED. v 2. ALL WIRING IN NORMALLY OCCUPIED (FINISHED) AREAS OF THE BUILDING SHALL BE INSTALLED CONCEALED FROM VIEW WITHIN THE BUILDING STRUCTURE. ryo�OpP�oQ.00�v WIRING MAY ONLY BE INSTALLED EXPOSED TO VIEW IN MECHANICAL AND ELECTRICAL ROOMS, AND ROOMS WITHOUT CEILINGS (EXPOSED TO STRUCTURE N, ABOVE). PROVIDE MINIMUM 3/4" EMT CONDUIT FOR WIRING RUN WITHIN WALLS, ABOVE NON -ACCESSIBLE CEILINGS, AND WHERE EXPOSED TO VIEW. PROVIDE EMT CONDUIT PENETRATIONS THROUGH WALLS, CEILINGS, AND FLOORS. PROVIDE NYLON BUSHINGS ON ALL OPEN CONDUIT ENDS TO PREVENTSLEEVES FOR ALL WIRING CHAFFING OF WIRING. 3. ALL RACEWAYS AND CABLE SHALL BE NEATLY INSTALLED WITH RACEWAY AND CABLE RUNS INSTALLED PARALLEL TO, OR AT RIGHT ANGLES TO, THE LINES OF THE BUILDING. OPEN CABLE RUNS INSTALLED ABOVE ACCESSIBLE CEILINGS SHALL BE BUNDLE TIED IN A NEAT AND ORDERLY MANNER WITH NYLON CABLE TIES. MAXIMUM DISTANCE BETWEEN CABLE TIES SHALL BE FOUR FEET. SUPPORT CABLE BUNDLES WITH APPROVED STRAP HANGERS. MAXIMUM DISTANCE BETWEEN STRAP HANGERS SHALL BE FIVE FEET. IDENTIFY CABLE BUNDLES WITH BUNDLE TAGS AT INTERVALS NOT EXCEEDING FIFTEEN FEET. IDENTIFY INDIVIDUAL CABLES WITH NUMBERED WIRE MARKERS AT ALL ORIGINATION POINTS, JUNCTION POINTS, AND TERMINATION POINTS. 4. PROVIDE WIRING AND CONNECTIONS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM WHETHER SHOWN ON THE DRAWINGS OR NOT. 5. THE RISER DIAGRAM IS FOR SCHEMATIC PURPOSES ONLY AND IS INTENDED TO ESTABLISH THE SYSTEM TYPE AND WIRING REQUIREMENTS. THE CONTRACTOR SHALL FURNISH, INSTALL, AND WIRE ALL DEVICES SHOWN ON THE FLOOR PLANS IF DISCREPANCIES OCCURS FOLLOW THE FLOOR PLAN SYMBOLS. 6. SEE FLOOR PLANS FOR LOCATIONS AND QUANTITIES OF MOTION DETECTORS AND DOOR CONTACTS AND CARD READERS PROVIDE QUANTITIES AS REQUIRED, WORK COVERED BY THIS DOCUMENT INCLUDES LABOR, MATERIAL, PRODUCTS, GUARANTY, TRAINING AND SERVICES FOR NEW AND FULLY OPERATING SECURITY SYSTEM AS DETAILED HEREIN, WORK SHALL BE COMPLETE TESTED, LABELED, CERTIFIED AND READY FOR OPERATION. INTRUSION ALARM SYSTEM SYMBOLS SYMBOL DESCRIPTION TYPICAL BACKBOX 120 VAC NOTES LOCATION POWER BY E.C. DOOR CONTACTS, FLUSH MOUNTED DOOR FRAME TO DOOR NONE REFER TO DC-2 1 OR 2 = DENOTES # OF DOOR CONTACTS &DOOR JUNCTION BOX NOTE B, E, H. DC DOOR CONTACTS, FLUSH MOUNTED DOOR FRAME TO DOOR NONE REFER TO & DOOR JUNCTION BOX NOTE A, D. DC DOOR CONTACTS, SURFACE MOUNTED DOOR FRAME TO DOOR NONE REFER TO & DOOR JUNCTION BOX NOTE A, D. CtILINU MOON I tU MU I TUN Ut I tC I UK "LR' (�FII IN( (SARI F ACCESS HOLE FOR N(1NF CONDUIT WITH NONE KEFEKIU LR LENS TYPES, = LONG RANGE , NOTE A, D. 24" SERVICE LOOP GROMMETED HOLE 4360 CEILING MOUNTED 360 MOTION DETECTOR WITH STANDARD LENS CEILING CABLE HOLE NONE, CONDUIT WITH NONE REFER TO ACCESS FOR NOTE A, D. 24" SERVICE LOOP GROMMETED HOL Hg WALL MOUNTED MOTION DETECTOR WALL MOUNTED CONDNG UITF WIT H BUSHINOTE NONE REFER TO LR LENS TYPES, "LR" = LONG RANGE. 96" AFF A, D. TO SURFACE �7 MOTION DETECTOR, WALL MOUNTED IN CORNER REFER TO ARCHITECT'S CONDUIT WITH BUSHING FLUSH NONE REFER TO \�Y I R LGhIQG TVDEQ "I D" - 1 Mir-1 DAKIGG -1.VI�V NOTF A D: l-I\Vl- 11 V, LI.IVII\VL. DWGS TO WALL SURFACE KP KEY PAD, INTRUSION ALARM SYSTEM 48" A.F.F. SINGLE GANG NONE REFER TO NOTE A, D, L. FACEPLATE SINGLE KIM= REFER TO U PANIC BUTTON, INTRUSION ALARM SYSTEM 48" A.F.F. GANG 1.W, NOTE A, D, L. FACEPLATE ❑S SIREN FOR INTRUSION ALARM SYSTEM 96" A.F.F. SINGLE GANG NONE REFER TO NOTE A, D, L. FACEPLATE AS AUDIO SENSOR: THE SENSOR PROVIDES FOR IMPACT ACTIVATED AUDIO DETECTION OF AN INTRUSION OR LISTEN -IN -AUDIO MAX 96" A.F.F. OR 6" BELOW SINGLE GANG NONE REFER TO NOTE A, D, L. (VERIFY) HIGHLY SENSITIVE MICROPHONES. CEILING O.C. FACEPLATE © BEACON FOR INTRUSION ALARM SYSTEM, BLUE 96" A.F.F. SINGLE GANG NONE REFER TO NOTE A, D. FACEPLATE IAS INTRUSION ALARM SYSTEM HEAD END 48" A.F.F. FOUR GANG REFER TO REFER TO BACKBOX NOTE "Y" NOTE A, D, N, Y. REFER TO NOTE W ACCESS CONTROL SYSTEM SYMBOLS TYPICAL 1E VAC NOTES SYMBOL DESCRIPTION LOCATION FACEPLATE POWER BY E.C. ACS-1) ACS-1 = ACCESS CONTROL SYSTEM, CONTAINS: ONE (1) CR, ONE (1) REX, ONE (1) DS, DJ, EL, PS, (IF APPLICABLE) EH DETAILS T501 SEE BELOW DESCRIPTION OF EACH SYMBOL 1 = DENOTES SINGLE DOOR. (A SC 2) ACS-2 = ACCESS CONTROL SYSTEM, CONTAINS: ONE (1) CR, TWO (2) REX, TWO (2) DS, DJ, EL, PS, (IF APPLICABLE) EH SEE BELOW DESCRIPTION OF EACH SYMBOL 2 = DENOTES DOUBLE DOORS CONDUIT WITH CONDUIT WITH F-D OADn DCAnCD nCVIrC AQ11 A C C BUSHING, FLUSH BUSHING, FLUSH REFER IVI\I V/'ll\V 1\L(1VL1\ VLVIVL 'TV ll.l .I . TO SURFACE TO SURFACE TO NOTES A, H, I. REX REQUEST TO EXIT DEVICE, MICRO SWITCH IN CRASH BAR MICRO SWITCH IN "EL" NONE REFER TO NOTES B, H, I. REX REQUEST -TO -EXIT DEVICE MOTION SENSOR ABOVE DOOR SINGLE GANG NONE REFER TO NOTE B,I. M ABOVE CEILING REFER ir\C1 I I1nnn C1TATI ICI C11AIIT(1 LI r"I 1 IC�I_I �A/\I I�ITr'r'\ VUUR J 1 m I UJ JVVI 111rl FLUJn IVIUUIV I CV AR IA(1CnIT -M mulimUCIV I IV NONE TO NOTES B, H, I. DOOR DJ DOOR HARDWARE JUNCTION BOX ABOVE CEILING ADJACENT TO TO DOOR NONE REFER TO NOTE B, E, H. JUNCTION BOX DOUR SEE DOOR SEE DOOR REFER EL DOOR ELECTRONIC LOCK A HARDWARE HARDWARE NONE TO NOTES B, H, I. SCHEDULE SCHEDULE CENTRALLY PS POWER SUPPLY FOR DOOR ELECTRONIC LOCKING DEVICE (EL) LOCATED IN REFER TO MDF &IDF NOTE A, H, I. SEE DOOR SEE DOOR REFER FER ELECTRONIC HINGE OR ELECTRONIC POWER TRANSFER. AS REQUIORED PER DOOR HARDWARE HARDWARE NONE TO NOTES B, H, I. SCHEDULE SCHEDULE ACH ACCESS CONTROL HEAD END LOCATED ON THE MDF WALL OR RACK SIZED FOR ALL SYSTEM REFER REFER MOUNTED CABLING TO NOTES Y. TO NOTES A, D, Y VIDEO SURVEILLANCE SYSTEM SYMBOLS SYMBOL DESCRIPTION TYPICAL TYPICAL 120 VAC NOTES LOCATION FACEPLATE POWER BY E.C. CCTV = MODULAR PLUG TERMINATED LINK ("MPTL") DATA OUTLET: CABLING INFRASTRUCTURE, INSTALLATION, TERMINATION AND TESTING PROVIDED BY TELECOMMUNICATION CONTRACTOR COORDINATE WITH THE "T" DRAWINGS. 12'-0" AFF WALL CCTV ONE (1) RJ-45, CATEGORY CABLE AS SPECIFIED (8P, 8C) CONNECTOR, FOR DATA CABLED TO DATA PATCH PANEL IN THE NEAREST OR IN CEILING AS NONE NONE REFER f 0 WIRE CENTER. AND AT THE DEVICE SIDE PROVIDE SIX (6) FEET LOOP AND "MPTL" INDICATED ON TO NOTES G. ( HORIZONTAL CABLE DIRECTLY CONNECT TO THE DEVICE DRAWINGS COORDINATE EXACT LOCATIONS WITH CCTV SYSTEM CONTRACTOR AND ARCHITECT BEFORE INSTALLATION. CCTV - SURFACE = MODULAR PLUG TERMINATED LINK ("MPTL") DATA OUTLET: CABLING INFRASTRUCTURE, INSTALLATION, CCTV TERMINATION AND TESTING PROVIDED BY TELECOMMUNICATION CONTRACTOR COORDINATE WITH THE "T" DRAWINGS. 12'-0" AFF WALL yWIRE ONE (1) RJ45, CATEGORY CABLE AS SPECIFIED (8P, 8C) CONNECTOR, FOR DATA CABLED TO DATA PATCH PANEL IN THE NEAREST CENTER. AND AT THE DEVICE SIDE PROVIDE SIX (6) FEET LOOP AND "MPTL" OR CEILING AS INDICATED ON NONE NONE REFER TO NOTES HORIZONTAL CABLE DIRECT CONNECT TO THE DEVICE DRAWINGS G. COORDINATE EXACT LOCATIONS WITH CCTV SYSTEM CONTRACTOR AND ARCHITECT BEFORE INSTALLATION. DOME CAMERA. "XXX" = DENOTES TYPE OF LENS, XX = DENOTES MOUNT TYPES, EX = DENOTES EXTERIOR RATED CAMERA. SEE LENS TYPES: ST = STANDARD VARIFOCAL LENS, WA = WIDE ANGLE LENS, TL = TELEPHOTO LENS, PTZ = PAN / TILT / ZOOM. MOUNT TYPES: CM = CEILING SURFACE, RC = RECESSED CEILING MOUNT, WM = WALL MOUNT, CR=CORNER MOUNT. PM = PENDANT FLOOR NONE NONE REFER TO NOTE A., G XXX,XX PLANS MOUNT, INSIDE OR OUTSIDE CORNER AS REQUIRED. 180° MULTI -HEAD CAMERA, "XXX" = DENOTES TYPE OF LENS, XX = DENOTES MOUNT TYPES, EX = DENOTES EXTERIOR RATED CAMERA. LENS TYPES: ST = STANDARD VARIFOCAL LENS, WA = WIDE ANGLE LENS, TL = TELEPHOTO LENS, PTZ = PAN / TILT / ZOOM. SEE FLOOR NONE NONE REFER i� XX r MOUNT TYPES: CM = CEILING SURFACE, RC = RECESSED CEILING MOUNT, WM = WALL MOUNT, CR=CORNER MOUNT, PM = PENDANT PLANS TO NOTE A., G. MOUNT INSIDE OR OUTSIDE CORNER AS REQUIRED. \ \ / 3600 MULTI -HEAD CAMERA, "XXX" = DENOTES TYPE OF LENS. XX=DENOTES MOUNT TYPES, EX = DENOTES EXTERIOR RATED CAMERA. LENS TYPES: ST = STANDARD VARIFOCAL LENS, WA = WIDE ANGLE LENS, TL = TELEPHOTO LENS, PTZ = PAN / TILT / ZOOM. SEE NONE NONE REFER i® XX MOUNT TYPES: CM = CEILING SURFACE, RC = RECESSED CEILING MOUNT, CR=CORNER MOUNT, PM = PENDANT MOUNT, PLANS TO NOTE A., G. / \ INSIDE OR OUTSIDE CORNER AS REQUIRED. CORNER CAMERA. INSIDE CORNER MOUNTED 96" AFF WALL +WALL NONE NONE REFER XX BS = BRUSHED STEEL FINISH WALL + CEILING TO NOTES A, G MOUNT VIDEO INTERCOM SYSTEM SYMBOLS SYMBOL DESCRIPTION TYPICAL LOCATION FACEPLATE 120 VAC POWER BY E.C. NOTES CEU RACK REFER TO REFER TO NOTE CEU - CENTRAL EXCHANGE UNIT, PROVIDE RACK SHELVING FOR INSTALLATION. MOUNTABLE N/A NOTE AT MDF X N REFER TO VES VES - VIDEO/AUDIO ENTRANCE STATION: WEATHERPROOF. 54 SPECIAL NONE NOTE ELECTRONIC LOCK PROVIDED BY DOOR HARDWARE CONTRACTOR. SEE SPECIFICATIONS FOR DETAILS. AFF A, D, H INSTALL REFER TO REFER TO IMS I IMS - INTERCOM MASTER STATION @ WALL 48" AFF SINGLE FACEPLATE NOTE NOTE DESK 18" AFF X A, D, X. GENERAL NOTE: ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT TO SCALE (N.T.S.) THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 9 Moody Road Building D Suite 18 Enfield, CT 06082 T. 860-341-1206 F. 860-239-1358 www.gtc.us.com L) -, - I w W .JOSEPH J NORTON REG. No. 202538R EXPIRES 12-31-20 w — • 91 moser piton nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE GENERAL SHEET TECHNOLOGY DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects I01LILOW01 �a 5 2 ACCESS / INTRUSION RISER DIAGRAM2 TOOA N.T.S. TOGA I I ' PtENUMCORET" Enclosure with Smart Receiver and Beacon installs in drop ceiling s; n.. SSR SS Lay -in Ceiling Speakers For even sound coverage U S-DI 3600 Ceiling Sensor r r Touch Control ° For AV Control i _ SWS SOUNDFIELD A WALL SENSOR SCP Teacher Microphone lysih ✓�itiiari vuttvr� For mute, voice command, Encore a"c and event trigger Student Microphone Teacher Edition 9g Easy to pass around AV Control and Lesson Capture Compact Desktop Charger iOS App Neatly charges bath mics For mobile -. ",,,,..... Alf Control Tro ector, computer, and electrical outlet not Included DIAGRAM COURTESY OF FRONTROW SOUNDFIELD SYSTEM RISEP Yhr} ISP ,y. A SAO Audio Out Wallplate For assitive listening systems HMN, 4Uriat] & USB 0 SAI VGA, HDMI, USB Wall Plates Connect computers, do,:: cams, or other devices As shown: C502 HDMI-X 1 WP-'PC SP-UCS-4 CB-b000 ENC-CB TE-C-USB %Aim h v V r-r� 202-05-103-00 202-05-102-00 202-05-10 1-00 TYPICAL RISER CABLES BY TC CONTRACTOR FROM THIS MDF TO IDF 12 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm MULTIMODE FIBER OPTICS 24 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm SINGLEMODE FIBER OPTICS, FIBER TERMINATION SOLUTIONS SHALL BE LC -TYPE VOICE RISER 25 PAIR INDOOR/OUTDOOR - PLENUM RATED CAT5E COPPER RUN AS ONE (1) 25 PAIR CABLE TYP. (5) 4" CONDUIT SLEEVE PENETRATIONS INTO MDF SEE ELECTRICAL DRAWINGS FOR ROUTING AND PENETRATION ROOF C V TELEPHONE C SERVICE C DEMARK POINT C CEILING 3 BROADBAND RF DISTR. I II SERVICE DMARK AMPLIFICATION IF I $1L R REQUIRED OCAMECHANICAL PBX.. aw 1 IDF _1- II Nil I I I D3 T SIGNAL TMGB 1ST � ��� n I — o FLOOn�nTlr JEE LC . JCI, 1 I5. R n o 0 COORDINATE WITH IT PERSONNEL IT IS OWNERS RESPONSABILITYTOENGAGE AND PROCURE ALL OF THE SERVICES NECESSARY FOR THE PROJECT EC SHALL PROVIDE (4) - 4"C. FOR TELECOMMUNICATIONS TO CL&P SERVICE POLE SEE SITE ELECTRICAL PLAN FOR CONTINUATION FURNISHED AND INSTALLED BY THE EC (1) FOR TELEPHONE, (1) FOR CATV, (1) FOR FIBER (1) SPARE BOND TO BUILDING SERVICE GROUNDING ELECTRODE, - SEE ELEC. SECTION 26 SPECIFICATIONS 1 ELECOIVIIRI VI SER DIAGRAIVI I N.T.S. P/A ROOF ANTENNA SEE SPECIFICATIONS TWIN DIPOLE, OMNI-DIRECTIONAL FM ANTENNA,PROVIDE PATHWAYS FROM THE MDF ROOM TO THE ROOF LOCATION OF DIPOLE OMNIDIRECTIONAL FM ANTENNA TO BE DETERMINE IN THE FIELD PRIOR TO ROUGH -IN ROOF PENETRATION FOR BEST FIELD OF VIEW/RECEPTION, SEE ARCHITECTURAL DRAWINGS FOR ROOF PENETRATION DETAILS AND SPECIAL SYSTEMS DRAWINGS FOR MORE INFO SOUNDFIELD SYSTEM SYMBOLS (NOTE: THIS SYSTEM SYMBOLS ARE FOR REFERENCE PURPOSES ONLY, SYSTEM SHALL BE PROCURED AS PART OF THE TECHNOLOGY SYSTEM PROCUREMENT PROCESS AT A LATER DATE. ALL BUILDING PREPARATION SHALL BE PROVIDED IN THE BASE BID) SYMBOL DESCRIPTION OI,OJrG RESPONSIBILIT Tvoirni I I r rvn� LOCATION RA('KROX BY DIV. 26 enn VMVAir-o ILU V/1l1 ru rVYVCR BY DIV.26 NOTES SS AV IN N/A NONE REFER TO SS - SOUNDFIELD/PA SPEAKER INTEGRATOR CEILING NOTES A, D, J AV IN REFER TO SSR SSR - SOUNDFIELD SMART RECEIVER INTEGRATOR CEILING NIA NONE NOTES A, D, J, X AV REFER TO SCP ® SOUNDFIELD CONTROL PANEL INTE INTEGRATOR 40"AFF 2-GANG NONE NOTES A, D, L AV REFER TO REFER TO SAO ® SOUNDFIELD AUDIO OUTPUT WALL PLATE INTEGRATOR 40" AFF 2-GANG NOTE X NOTES A, D, L, x SAI nl11 IAlnrlf n AI IMIn IT IAInl I III ATc AV iNTEGIR�T�P 18" AFF 3-GANG NONE REFER TO 17 lKIMI ODUNUrICLU /IV VIV IIVrV I YVr1LL rLt11 L IVV I tS A, D, X SOUNDFIELD INTERCOM MICROPHONE AV MOUNT IN SSR N/A NONE REFER TO NOTES A, D INTEGRATOR SWS D SOUNDFIELD WALL SENSOR AV INTEGRATOR T-8" AFF N/A NONE N/A SOUNDFIELD DATA FEED TELECOM FEED WITHIN NIA NONE REFER TO S D1 D SINGLE (1) RJ45, CATEGORY CABLE AS SPECIFIED (8P, 8C) CONNECTOR, FOR DATA CABLED TO DATA PATCH PANEL IN THE NEAREST WIRE CONTRACTOR SSR NOTES A, G CENTER. PROVIDE TWENTY (20) FEET LOOP AT THE DEVICE SIDE AND A "MPTL" TERMINATION, HORIZONTAL CABLE DIRECTLY CONNECTED TO THE DEVICE, COORDINATE LOCATIONS WITH WAP SYSTEM CONTRACTOR AND ARCHITECT BEFORE INSTALLATION. INTERACTIVE SHORT THROW PROJECTOR THIS WILL BE PURCHASE AS PART OF THE TECHNOLOGY EQUIPMENT PROCUREMENT AV SEE ARCHITECTURAL NONE POWER INTEGRATOR ELEVATION FROM PDC N/A ISP GENERAL NOTE: THE SOUND FIELD SYSTEMS, PA INTERCOM, LOCAL SOUND SYSTEMS DRAWING AND SPECIFICATION ARE FOR REFERENCE PURPOSES ONLY. SYSTEMS SHALL BE PROCURED AS PART OF THE TECHNOLOGY EQUIPMENT SYSTEM PROCUREMENT PROCESS AT A LATER DATE. ALL BUILDING PREPARATION SHALL BE PROVIDED IN THE BASE BID SEE 27 05 00 - COMMON WORK RESULTS FOR COMMUNICATIONS THERE YOU WILL FIND SPECIFIC REQUIREMENTS. ROOF CCTV C C 7 ]D n E 3 CRP 1 CORRIDOR PA ` S LRM TYPICAL RISER CABLES BY TC CONTRAC R 12 STRANDS ARMORED - PLENUM RATED OM3 IDF 205 50µm/125µm MULTIMODE FIBER OPTICS 24 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm SINGLEMODE FIBER OPTICS, ERMIN. FIE PP FOPP PP FIBER TERMINATION SOLUTIONS TYP. PP i ITCH (N PP SHALL BE LC -TYPE SIGNAL TGB, EPP PP VOICE RISER 25 PAIR IIVDUUR/VU I DOOR - SEE 26SECT. PLENUM RATED CAT5E COPPER RUN AS ONE PP PP (1) 25 PAIR CABLE PP PP TYPICAL FREE n n n n STANDING RACK ASSEMBLY u u u u WAP WIRING TO THE NEAREST WIRING CLOSET TYPICAL C4--9 � IT 115 I I+LA�arcvvrn PDC � VI on _-cT�V_1� ACCESS NTERCO �g PO_ J CONTRO W PP COCK KVM SCH D2 H PP MONITO PP SYSE M INTRUSION D3 PHONE ETECTICI PP FREE S_YS_TEM V STANDING RACK NOTE: TYPICAL NETWORK EQUIPMENT RACK(S) WITH MOUNTING KIT AND GROUNDING KIT, PROVIDE PATCH PANELS AND HORIZONTAL AND VERTICAL WIRE MANAGERS AS NEEDED PER QUANTITY OF DROPS. PLUS 20% SPACE FOR GROWTH AND TO HOUSE ANY CUSTOMER PREMISE EQUIPMENT. TYPICAL COPPER GROUND BUS ON THE PLYWOOD BACKBOARD BY E.C.. CABLE TRAY, LADDER TRAY, ALL EQUIPMENT RACKS, ALL TELECOMMUNICATIONS SHALL BE BONDED TO THE MAIN TELECOMMUNICATION GROUND BUS "TMGB" MOUNT AT HEIGHT NEAR LADDER RACK FOR EASY ROUTING AND MANAGEMENT OF GROUND CONDUCTORS, REFER TO SECTION 26 SPECIFICATIONS AND DRAWINGS CATV SERVICE (IF APPLICABLE) DEMARC POINT THE TELECOMMUNICATION CONTRACTOR IS RESPONSIBLE IF NECESSARY TO EXTEND THE CATV DEMARC FROM THE SERVICE ENTRANCE TO THE MDF (IF REQUIRED) TERMINATE RACEWAY WITH PLASTIC BUSHING IN AN / nrr�cclRl G I nr ATlnnl ORnvF rFll IMr.1 TYPI(:AI — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J — — — — — — — — — — — — — — — — — — � .— ... — STRUCTURE SM �(// P ___14_� I IIIXII -.��� ��l_�l_-�__-- _-- _-- ----- - ---- -- - - - NG---- - - - - -- L-- oi SL OLR - - -- --- -- TYPICAL 3/4"C.M) M-----IXII - -------- - 11L4"_- - - FOR- - R FLt�i� CONDUIT PDC POWER DS EL.:COORDINATE HEI Hl- WITH ARCHITECT E:21 XII WP BY E.C. - - BY E.C.- M AL - r UNLESS_ EL.96"A.F.F. - - ANT--F=C L - - - - - - - - - - - - - - - -SL - - - - - - - - - - - - - - - - - - -NOTED - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EL.60" A.F.F. L.54" - - A.F.F- -. - - - - - - - - - - - - - - - - - - - - - - - - - - E — — — — — — — — — — — — — — - EL.48" A.F.F. - TERMINATE RACE WITH PLASTIC BUSH WP WEBA {{�---------- - - - - - - - - - - - - - - - - - - - - - - - - ii - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EL.18" A.F.F. U.N� FLOOR is E z U N 2 O_ z 0 NOTES THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AT THE PROPER LOCATIONS ALL CABLE PATHWAYS INCLUDING CONDUIT, SLEEVES, PULL STRING, OUTLET BOX, PLASTER RING, INSULATING BUSHINGS, FLOOR BOXES, WIRE TRAY (IF APPLICABLE) AND 120 VAC POWER REQUIREMENTS. ALL DESCRIPTIONS AND NOTES ON THE TECHNOLOGY DRAWINGS AND SPECIFICATIONS RELATING TO ELECTRICAL ITEMS ARE FOR REFERNCE PURPOSES ONLY. REFER TO ELECTRICAL 260000 DRAWINGS AND SPECIFICATIONS FOR ACTUAL REQUIREMENTS. TYPICAL DIAGRAM CONDUIT SYSTEM N.T.S. 1 WAY - - - - - - - - - - P SWSQ D6 - - - - - - - - - - - - - - - - - - - - - - - - - - - D4 ING SAI SAO SCP D3 A D2 0 DX (REFER TO GENERAL SHEET FOR TECHNOLOGY OUTLET DETAILS.) COORDINATE WITH ARCHITECT AND ARCHITECTURAL DRAWINGS FOR INSTALLATION HEIGHT AIL" CLASSROOM D3 �7 WIRING TO THE NEAREST WIRING CLOSET TYPICAL PDC TYPICAL CLASSROOM W D3FLVP If D2 7 WIRING TO THE NEAREST WIRING CI-OSET TY�AL PDC CLASSROOM D3 lrCiL1Ne"G SECOND FLOOR CEILING FIRST FLOOR WAP CCV' — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — STRUCTURE DUIT F 1 E-.C. WAP -- ------ --ON 3/4'C.--------- BY TYP.C. -------- - -- � RC CEILING --- ----- - - - - - - - -------- POWER M BY E.C. WAP CCTV WM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - P 1 1/4 1 1/4" WM CONDUIT CONDUIT - - - - - - - - - - - - BY ES- - - - - - - - - - - - -BY-E.G- - -- - - - - - - - - — _ TWO PIECE DIVIDED SURFACE RACEWAY -IF APPLICABLE) _ - - - - - - - _ - - 9 - - - - - - - - - - - - - - - - - - - - - - - - LL. Ll u Q g g g'g MEN e� DES LL: o M J u- `0 - - - - - - - - - - - - - -------------- - - - - -- _ D3 E D3 bo d T FLOOR FLOOR BOX OR POKE-THRU REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 M+� � U o � Q o Z Q�WF W U x zoo w�� w r z o x o � H a w all I � U 0 0 z d 9 Moody Road Building D Suite 18 (5 Enfield, CT 06082 ti T. 860-341-1206 F.860-239-1358 c www.gto.us.com a TIONS 4v Lf/CSB 1U W JOSEPH J NORTON r REG. No. 202538R = EXPIRES 12 31-20 • mncar pilon nelson architectE. 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE SOUND FIELD SYMBOLS AND RISER DIAGRAM DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. T100B i �C C z U N O Z REVISIONS CONFORMED SET MARCH 22, 2019 I I I i I I I • ENGLISH I I LEARNERS ' 4 (127) T200 • 1 T "t � � • • TYPE rrDrr SOUNDFIELD-SYSTEM '\ / TYPE "B", s - 1 1k111CIC1 r% �?V�+TC11A / SWS \ / ! i � 1 � � s Q�! d a g Q '. I I 'V • AS � - ,,. , I .D�-2 101.�------5`OFtfiIfiS�At -- 1 i i , ---- T Q r B H TELEPNE WAP _ • i_ _�- VISUAL ARTS I \ / A ° d ° a COORDINATE CLASSROOM a s QQ Q d }. � j LOCATION WITH LEVATOR A Bi NvNTRACTOR tf Ap3 � I l , J — �D3 — — J \ — WAP DASHED LINE DENOTES I ELEV. IDF ROOM AT FLOOR L 1 ISP GENERAL MUSIC (120) / 1ABOVE I r r n I D L_ — vv_AP� vc J TYPE B 1 \ CUSTODIAL SOUNDFIELD SYSTEM J I / I \ STORAGE \ / KILN ROOM V 119E i ' \ Li WAP \ D� 1/T101A\ -----� D3 / INSTALL 24" A.i .F. I TOILET 121 � AS PSYCHOLOGIST \ / . _........ ®VCVC ®� - \ L i L // • � S-D1 S S!S �� • I_- RELATED ' • / \ I\ �d SERVICES SUITE \,, � ,;�/ I a ISP I ' 1 \ SWS D3 \ CONFERENCE LR ROOM t� �. — iT TEl�CHER WORKROOM 124 / OTIPT RESOURCE �2, I IA /U W ROOM SWAP FLVP �® D3 U I VC c 1a I _ U I Val/ C 1 1 TOILET V 1 TYPE rrDrr / I 122 I Cll - _ D3 B o I SOUNDFIELD SYSTEM , I 03 / W D2 LA PDCLL / o I \ ----A_ -_w — TYPICAL NOTE: — — — / \ — —� AC� VESTASLEKP 3 u VES ACS / CORRIDOR / ANY CONDUIT CROSSING THE EXPANSION JOINT / \ MUST HAVE A CONDUIT EXPANSION JOINT / LR M �181.1 0 180.11 T, PM, / ® / INCORPORATED TO ACCOMMODATE MOVEMENT. / EASTkOBBY � CCTV v. j \ / Fc \ _ — — 181.2 DC-1 / 180.2 DC=1 l.� - -- ---- -- P \ B 0 ^� _ d \ r^? a W— \ ACS D3 / \ \ - WAP p MEDIA CENTER 0 IS /®/VC J \ r] VIC i \ i — � l 0:( < D2 ULTY LOUNGEI D2 Q _ \ /� D3 ® 1 _ 103 Y __ U PB I 1 r r r r I �' U Co❑ TYPE C TOILET WAP 1 SOUNDFIELD SYSTEM ® / D3 WRAP i 1�?)—� - ! o IMs HEALTH SERVICES VC/ 102) _ 2 CONSULTATION - 1 _.__.. VC / � � D3 Ro2g VC D2 \ PAI S \ ! TOILET MAIN OFFICE SECRETARIAL r D3 VC 1t�1C) /!' AREA \ A P I (� IP / _ -- , _ a L Y� MAIN OFFICE CON'FjI NCE / ROOM USA FPD ii 11 / I WAP _ FLVP —' 1 1 - ------------ I — — ` rPRINCIPilAL'S O FFICEV . 6 ---- � �— J AS AS C` � � CCTV \ 2 FIRST FLOOR PLAN - PART B T101 1 /8" = 1'-131" SOUND FIELD SYMBOLS I zSS ®ACS-1 �- ®. ACS if! J - I _ — D3 ; i D3 _ S- AS ti / KINDERGARTEN • SCP KINDERGARTEN j SAO 133 / , cc) .f� �. .�. .L �. ISP' � _- � •- � , � r^a� J j '\ — j � ISP -1� I(--�,• I, J C� i TYPE " A7 -0 r_- TYP1 SOUNDFIELD- SY-STE 50UI4bFIEJ NI • j / VESTIBULE C,CT _ Z AC ' 194 , n �. 4 AS \ / VES ® ---- — — ---— , TOILET TYPE rrBrr - - -- SOUNDFIELD SYSTEM ; I � 11 IJ l� J 1, J:H, � i I _ r 1'CD:_ - \ U CLASSROOM D 131 I ISP AS -- ----- — ° / i TOILET i _� / ....TYPE "Brr � I.SOUNDFIEL;D SYSTEM fl WAD DASHED LINE DENOTES IDF ROOM AT FLOOR ABOVE PARTIAL FIRST FLOOR - NORTH 1 /8" = 1 '-0" "All SYSTEM i I �C C, C, -- -F)3•I � L — KINDERGARTEN I 134) \ \ RC CCTV READING INTERVENTION 139 1 o IVES A�CS� rj; CCTV ST, PM \ I ,J / 1 I h REFER TO ARCHITECTURAL FLOOR PLANS, REFLECTIVE CEILING PLANS AND ELEVATIONS FOR ALL TECHNOLOGY DEVICE LOCATIONS AND DIMENSIONS, TYPICAL STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 e I I p _ zz 1 a Moody Road 9 Building D Suite 18 c� Enfield, CT 06082 T.860-341-1206 F.860-239-1358 c www.gtc.us.com N C w w JOSEPH J NORTON m REG. No. 202538R = d EXPIRES 12-31 20 • (;;_ �_c / mncar ■■■vvv■ pilon nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PARTIAL FIRST FLOOR PLAN - NORTH & SOUTH DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. T101A REVISIONS CONFORMED SET MARCH 22, 2019 ti DC-2 DC-2 •� 1 C17.3) I t7.2)AS X li f WRAP FL,A� W 1 TVnC ��CVr I�_ �.� \w I _ - V Ir • I c � � 1 r s= IL �1 1 ---- �- -- - - FIELD - - - -- \ SOUND I� SYSTEM MOUNTED SPEAKERS pRn_\il_nF_ Sl IRFACE_ WALL t / -- - �� ! • � ; �' ACS-t I (� 185.2 Ir "CII ® if I � 0- ISP GYMNASIUM TO LSER I I G LOCAL SOUND SYSTEM TO WB INSTRUMENTAL S BE PURCHASED THROUGH D3-- —MUSIC-AND_ __ PROCUREMENT. 1D2 DI ® — — ��— PDIA- C 4 /Y IT 115 II WALL BOX WILL HOUSED ( PDC FOR REAR PROJECTOR S LADDER RACK AS NEEDED it ;� D2, FLVP, POWER AND LOCAL • COORDINATE WITH AV • DATA TERMINATION AS NEEDED �_ "_�! ., . - _ _ SOUND CONNECTIONS INTEGRATOR -FOR HEIGHT AT VOICE TERMINATION FIELD AS NEEDED N / _ MlfdiMUM LOCATION SHALL BEAT \ ' MTGB, GROUNDING BUS BAR AS NEEDED 11 4' W x 8' H LENGTH OF ENTIRE WALL "C" IICII I i PLYWOOD BACKBOARD 3/4 x o f IDENTIFICATION LABELS LABELS SHALL BE IN ACCORDANCE WITH THE ANSI/TIA/EIA 606 STANDARD / I �`' - • \ J • ' J / I I l 11 I (ACS-2 --- - o --- AS Y / W r TO LSER A S-2 117.1 / \ / - - - - _ - \ LOGA�rSO SOUND RACK +J fir--'- -- FL, WAP - V�CD - A�S-1 J C W AP \ I 4 �1 , 4� •• / V I J \ II Ii _ vE OFFICE \ \ P.E. p I - COORDINATE DATA ' I LOCATION FOR BUILDING IT I C1.16DIAL CHAIR STORAGE MANAGEMENT SYSTEM ! 115 I STORAGE 1 - ,, \ P.E. STORAGE A { / � � \ I \ 11 / \ �VC —' BE/71/304E DE PATHWAY \ % -D3, I TOP SEE116 SIMILARI \ / / \ \\ ST;�RC > STORAGE; > �• •'�••li' \ PROVIDE I D�o`R \ WAP \ \ \ �' - U 118 I F 2 PARTIAL FIRST FLOOR - WEST T101B 1 /8" = 1'-0" I OCR \ \ I � 1 VISUAL ARTS Itill WAP CLASSROOM CIE I / I ISP i KILN ROOM Of) V)SUAL ARTS I 119E i r STORAGE -- - \ SOCIAL WORKER -- WAP\ 17 ISP ` � D3 \ (D 1 Vp/ j GENERAL MUSIC 1 / T101A 120 2/T101 D3 / I WAP INSTAL �T qT 17 24" A.�.F. ! ......... ........ ... ........ .il TOILET TOILET TYPE SOUNDFIELD SYSTEM - MAD y� I COF3RI � � 7-741 F- r � I -- r n YYI v 'tom I 7_+ ---_-_ •— ® WAP \.DOOR � v / \ CONTACT AT ® I j 188 UNDER COUNTER RACK / / / LR � I ' FOR LOCAL SOUND -SYSTEM TV L,F( ST, RC\ N R079F\HATCH I / ® - / DiV. 26 PROVIDE POWER_ CORRIDO / - , I \\ - CORRIDOR � \ 1 ___ o SAN1OiV SRK12 -- n 183 �,/ \ 6 i --- _. Iu / \ U_- -_,--- /4n o �J :� UND OUNTER U \ C,' , \ _ TOILET I3-j 1 l-- 112 \ ® KITC�-II STORAGE GIRLS'TOILET — _ BOYS'TOILET \ / / \� ABOVE / Lam, GG RACK3.6"H X R , \ \ / i C� COUNTER / 18.11YD X 19.wW / I ' �A i H PROVIDE GROMMET AT COUNTER / / / \ 1--T--� �� ��— �! VG Own tJ LEVEL AT SIDE OF CABINET �H I-L =- ' TYPE C = v -P - ifoA) crm wn_rwi n -gVRTEM \-----•_-- / :' \ MEDIA CENTER I I MEDIA GEN I tK VC > i / O1fFIICE LOCAL SOUND SYSTEM TO - \ / BE Pl7RCHASft3THROUGH \ I — \ TYPE 'rC" 6A / I _ - - - \ I \ PROCUREMENT. /I I ,. \ �N. ����r-�c1 n �+VC-r R 1 'v�DE� �VUIVVt'ICLV 7 i �7 1 GIVII `y ---- Ci�€ffiERt / PRODUCTION ' r- UCTION LAB �.. 0 - _ ACS-2 ( 190) % 104E __ t —- t v VC VC VEIBULE' WAP R I / \ _ - — / STEM LAB I ISP D3 %VC - �o NIL / I WAP /- w �1 G - -, KP 105 0 r� ► V _- __ UIL1 s I \ AP_ cc DATA DROP Q- ---' i V - -[- W FOR POS -- - - H T87 1187.4 _ I I j C/) I COORDINATE \ I DC-2 I ACS-1 - ",' _� / �EL LOCATION i f ;it II� - FOOD MANAGER'S KITCHEN D2 \ WAP _ - -, \ I IVES I I®P P -- '- I - \ I D2 ' \ AS I 1096 '� i V -1 V - � VC _' / � VC D2 � � U I OFFICE � 709 / \ MOUNT RKIOT FOR - \ i I I -- - MEDIA CENTER I / IT VC\ - INS,®UG \ _ ORKROOM �VC I I SPEAKERS AT SLOPED \\ / rr\ II \ A D2 104C AS I� CUSTODIAL D3 � \ CEILING AREA I lill OFFICE.--- -- _. _ _tp V3 \ j I / oc - -- �\ / / \ {r \ -D^ -J D2 D2 III I 110 I� I I / LU � - As 0, , LL*L � � I i uI AS REFER TO ARCHITECTURAL FLOOR PLANS, REFLECTIVE CEILING PLANS AND ELEVATIONS FOR ALL TECHNOLOGY DEVICE LOCATIONS AN DIMENSIONS, TYPICAL STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 x U � o � Q s WF x Zia � O O �wz o x H a j ci o 0 t 9 Moody Road Building D OUIM; ie L Enfield, CT 06082 0 T. 860-341-1206 F.860-239-1358 c www.gtc.US.COM a O -Bic-si 2 Wn w �JOSEPH J NORTON � REG. No. 202538R d EXPIRES 12-31-20 moser piton nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PARTIAL FIRST FLOOR PLAN - WEST DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E m z U .O ^L n z n G r T101B I REVISIONS CONFORMED SET MARCH 22, 2019 P/A ANTENNA COORDINATE LOCATION 2.0 - OVERALL TECHNOLOGY SECOND FLOOR PLAN 1/16" = 1'-0" -De-1 --- DOOR CONTACT AT ROOF HATCH REFER TO ARCHITECTURAL FLOOR PLANS, REFLECTIVE CEILING PLANS AND ELEVATIONS FOR ALL TECHNOLOGY DEVICE LOCATIONS AN DIMENSIONS, TYPICAL T 2) AA.3 (MM) PP TT T. UU QQ --- ---- -- - - - ------ - -------- II =t �-�-;--=-►�-+ 7-1---►--�---}=-�-a -T-;->t=-i-=1--a-+:-r=-1.�-F---F-=�:--F�.-r--�--r'-tY-c-•-�---r--1-a--t-'�-�- _ 2 SCOPE WITHIN BID ALTERNATE #1- I� f, N r` 2 �2 � IL _ -�� 2 2 '� 2�; H OW 4/48D DD t 1 24,48LL C� o 71 f- — — — I, ; 2 Ill!llli li — � '' I Iliiil�ll i I `�, I lililllll�l I J - PROBABLE CABLING ROUTING TO IDF 205 I I }� Y , t IDF 205 I 24r48 TYPICAL RISER CABLES BY TIC CONTRACTOR 12 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm MULTIMODE FIBER OPTICS \ 24 STRANDS ARMORED - PLENUM RATED OM3 I k y rit y :t y.S r , I 50µm/125µm SINGLEMODE FIBER OPTICS, {_ �2,, FIBER TERMINATION SOLUTIONS SHALL BE LC -TYPE JJ 11 '' VOICE RISER 25 PAIR INDOOR/OUTDOOR - PLENUM \ RATED CAT5E COPPER RUN AS ONE (1) 25 PAIR CABLE- �l TO MDF 115. I' IDF 205 I 4'� ; � r 1 Ll LADDER RACK AS NEEDED I \> L�-�-r' `2 �2 DATA TERMINATION AS NEEDED VOICE TERMINATION FIELD AS NEEDEDG�1�- j WIRELESS TERMINATION AS NEEDED I( "aiaao �� I� i a4 as l� ELECTRONIC SAFETY AND SECURITY CABLING AS NEEDED I -- - TGB, GROUNDING BUS BAR AS NEEDED PLYWOOD BACKBOARD 3/4" x 4' W x 8' H, LENGTH OF ENTIRE WALL 2 L n I I IDENTIFICATION LABELS SHALL BE IN ACCORDANCE WITH THE ANSIMA/EIA 606 STANDARD �414 I, - - — 24/d8 Ir r I PL -T--,L- { - 13 I -" rrr'Ir.i �r lrlrr - IIIIIIIIII�lilll,"". I I III��III II�IIIII. � (GG� -2� { 17 1 DOOR CONTACT _ AT ROOF HATCH {21 ( ABOVE HERE - I I C De-1 nn _ 25 _ f 1 - .1 `C_C_ 14 202 { 26.5 I 2 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 U ' J J yyI 4 0 i I � 1 V 9 Moody Road Building D Suite 18 Q Enfield, CT 06082 T.860-341-1206 Q F.860-239-1358 www.gtc.us.com N C.Cf, �' Bic s z 151 r�JOSEPH .J NORTON rm �� REG. No. 202538R � EXPIRES 12-31-20 0 moser piton nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE OVERALL TECHNOLOGY SECOND FLOOR PLAN DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. WE T102 Z.2 3 )3 \"s I FF KK iMM PP REVISIONS CONFORMED SET MARCH 22, 2019 SCOPE WITHIN BID ALTERNATE #1 `Z.2 i�-3�) (BB) (DD) HH KK MM QQ TT T.6 X i XA j i LU 1Ili1 l lull � r, L TYPE r�rr TYPErrCrr , _ SCE FIELD SYSTEM , SOUNDFIELD SYSTEM- - D2 CORRIDOR _ - --D2 -SWS- _ \ \ -.. , �. 1=3 ' -- -- ii - _ SOUTH STAIR / r'v-47'CL SS jj r - \ 01D :D _ I \ i _777 ® �..WAP T \ PE rrCrr I / 5 ®(ACS-1 WAP \\ SOUAPFIELD SYSTEM ITOILET_ / 1 1 r­7OILET INSTRUCTIONAL \ STORAGE PROVIDE \ / GENERAL \ DOOR CONTACT STORAGE AT - 2a2 - ROOF HATCH / `eA) BOYS' TOILET I / VC 219. I •-- � � WAP \ > JD3 \ 04U (r I U U \ -tsP = I I TYPE LR $OUNDFIELD \ SYSTEM 1 I E) - - - \ WAP SPECIAL \ 0 EDUCATION ' NN I �A� GIRLS' TORT RESOURCE ROOM: 1; \ VC zoo CO \ EAST LOBBY A (HH)/ _ _ 14' m _( 22 (SOS VV I QQ �—-----------------------------------------------------------_-----I r— -r- -r-,- 0 - -- -- ------ - - - - _ --- - - — - ---- -- ---- --- ---- -- ---T - : - -- - --- - - - i 11 ;_._.. UH i . -�` / \ TYPE C '�, / - - ` TYPE G SOUNDFIELD Y EM SOUN STEM SOUNDFIELD SYSTEM I UT.:. � • .��_ _` WAP G Job j WA i EE , F-1 \ f I Ico ISP i 1 - o rl - ffn1— rL Ul LL - r__. --- ---------- ­24 NORTH I - _ z ,I -- _ K I — — — — — — — — — — — — — — — — — — — — ---- licit 1 _I TYPE rrCrr, / / T PE rrCrr j \ SOUNDFIELD SYSTEM _ / _ SOUNDFIELD SYSTEM '� \ ! I ' iIII I _ _jkV i!I U_w� t [\ .. [ lJ l� �LLt r j GRAD 5 G 5 it I [' CLAS R 1N C S 0 <, '-- • '---• ,I / �_C \ fl I / ISP � \ \ / � ISP II X DC / \ ISP � / '/ / O \ ` ISP l \ \ GRADES 3.5 / GRADES 3.5 ' / [ ryry3 CLASSROOM ! ti / CLASSROOM — P3 B \ Al- - I (; A t.. (.:..� I I I FH� I II'j I 1 TYPE _ -T PE rrEr, \ \ SOUNDFIELD SYSTEM ` / H SO ' D IELD SYSTEM / L. \ A. TYPE moo / TyPE „Crr \ / / 1 SOU-N_DFIELD'\,SYU-EM - , 80UNDFIELD SYSTEM ! ;;� ` 17 1 3- i I li I i I Ct 0' �..� ( �. , 1. �. _HGDES 3-5 I 3 / \ L 207 \ \ _ r_.._ _ \360 215 G3 \ ; ISP @ � ® ISP / PDG1 ap mo M� ��__�� v ll�� SWS O / ISP (D r / / • \ �J ISP cUn 0 - \ \ GRAD 0 / III CLASS ZOO I • GRADES 3.5 0 CLASSROOM �.._.� WA 6 jjj • o `\ TYPE rr / - TYPE" c" - _ , O II ' SOUNDFIELD SYSTEM-- SOUNDFIELD SYSTEM I 0 \ i D2 CORRIDOR _ D2 SWS LI \ III , \ •m•.. .®® _ir.L. . ..00 \ ✓ \ , }O ISP \ ✓ _ i / _- - --_ -- ---I --i r.., s GRADES3.5 D' > ' " CLASSROOM i- Z1 I REFER TO ARCHITECTURAL FLOOR PLANS, - REFLECTIVE CEILING PLANS AND ELEVATIONS FOR ALL TECHNOLOGY DEVICE LOCATIONS AN DIMENSIONS, TYPICAL STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 FOj � P y 4 0 I ii L 9 Moody Road Building D Suite 18 c) Enfield, CT 06082 T.860-341-1206 F.860-239-1358 0 www.gtc.us.com N (U! c,r uaj: JOSEPH J NORTON REG. No. 202538R EXPIRES 12-31-20 moser pillon nelson arch itect.c. 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE PARTIAL SECOND FLOOR PLAN - NORTH & SOUTH DATE 11 /02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 3 PARTIAL SECOND FLOOR PLAN. --SOUTH Ti o 1 /8" = V-0" PARTIAL SECOND FLOOR PLAN - NORTH 1 /8" = V-0" T102A !� MM t? REVISIONS FFF CONFORMED SET MARCH 22, 2019 L E z U 0 IL z n 2 CT) TYPICAL FOR "SWS" PROVIDE CONDUIT AT T-8" A.F.F. SHALL BE 1" CONDUIT WITH PULL STRING, STUB AND BUSHING TO ACCESSIBLE CEILING I I r IlJP1L 1 VI 1 vvvv PROVIDE CONDUIT AT 7-8" A.F.F. SHALL BE 1" CONDUIT WITH PULL STRING, STUB AND BUSHING TO ACCESSIBLE CEILING C-IRADFS 3-5 CLASSROOM TYPE "C" SOUND FIELD SYSTEM 1 /411 = 1'-0" PROVIDE COTYPICAL FOR "SWS" PROVIDE CONDUIT AT T-8" A.F.F. SHALL BE 1" CONDUIT WITH PULL STRING, STUB AND BUSHING TO ACCESSIBLE CEILING ­1 w-r-1 — w r - ., - i'm --tow -don em.G 1 TFIV/'1 L..1 VR vvvv PROVIDE CONDUIT AT 7-8" A.F.F. SHALL BE 1" CONDUIT WITH PULL STRING, STUB AND BUSHING TO ACCESSIBLE CEILING GRADES 1-2 CLASSROOM TYPE "B" SOUND FIELD SYSTEM 1 /4" = 1'-0" f BB FF KK (MM PP TT T.6 UU QC — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — �., r---r - r 7-i---r - = T -ram —77 T_ T T 7 1-7 t i t--T --1 I _ _ I _ TI _ =, SCOPE --►I WITHIN BID ALTERNATE I YPE A SOUNDFIELD/"A" TYPE A SOUND - L D { ., .. - - II SYSTEM SO`lJNDFIEL I E I - 11 it i n n i, SYSITEIM ( -� �.-a� �� SYST M - I It WAP _ I 17, - �D I HH.1/3 v I3 ) IE6j : < —. \ ISP ISP \ ^ 1 L / - 2 o - - - [D III --------1 i U. ! AS S U �I I U / r' NORTH STAIR S20 LR — -- _ 6 L _ - - 14 TYPICAL FOP PROVIDE CONDUIT AT T-E SHALL BE 111 CONDUI PULL STRING, STl BUSHING TO ACCE C - 13 5/ � o Lj \ CORRIDOR i � C 192 KlrninFRnARTFN TYPE "A" SOUND FIELD SYSTEM 1 /411 = 1'-0" 1.4 STATE PROJECT NO. 132-0089 N TYPICAL FOR "SWS11 PHASE 2 OF 5 PROVIDE CONDUIT AT 7'-8" A.F.F. SHALL BE 1" CONDUIT WITH PULL STRING, STUB AND BUSHING TO ACCESSIBLE CEILING (MM C1Q TYPICAL FOR "SWS" PROVIDE CONDUIT AT T-8" A.F.F. SHALL BE 1" CONDUIT WITH PULL STRING, STUB El WN Q x O � Q 0 z �Wo WH U H w�� w zW°o �x o a i w I � ,3 - I s 9 Moody Road Building D Suite 18 0 Enfield, CT 06082 w T.860-341-1206 F.860-239-1358 www.gtc.us.com N T10NS MCS/ G2 IS � JOSEPH J NORTON M REG. No. 202538R � EXPIRES 12-31-20 � 7GNATURE AND BUSHING TO ACCESSIBLE CEILING moser SWS pilon AS o ® nelson SS SSR ss S-D1 architects 30 JORDAN N C WETHERSFIELD,CT. 06109 Room - 22) (860) 563-6164 SPECIAL EDUCATION TITLE RESOURCE ROOM c 1 0 ) ENLARGED PLANS AND ALTERNATE L 1P #1 FLOOR PLAN SwS U_ J \ D3 TYPICAL FOR "SWS" — PROVIDE CONDUIT AT 7-8" A.F.F. - 26 SHALL BE 1" CONDUIT WITH PULL STRING, STUB AS AND BUSHING TO ACCESSIBLE CEILING DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. IDARTIAI cFrmmn FI nnn PI AN - NORTH - ALT #1 1 /811 = 1'-011 .1 `� PARTIAI FIRST FLOOR PLAN - WEST - Callout 1 Zoo) 1 /4" = 1'-0" SPFC ED RESOURCE ROOM (OR SIMILAR) TYPE-"D" SOUND FIELD SYSTEM 1/4" = 1'-0" T200 I REVISIONS CONFORMED SET MARCH 22, 2019 TYPICAL RISER CABLES BY TC CONTRACTOR FROM THIS MDF TO EACH IDF 12 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm MULTIMODE FIBER OPTICS 24 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm SINGLEMODE FIBER OPTICS, FIBER TERMINATION SOLUTIONS SHALL BE LC -TYPE VOICE RISER 25 PAIR INDOOR/OUTDOOR - PLENUM RATED CAT5E COPPER RUN AS ONE (1) 25 PAIR CABLE -r.,� rl r-11AT1r-Nm nc TGI 1=r_MANA1 INIr.ATInN ROOM "TR" WITH 3 RACKS 1 11 . 1_LL vF_% 1v,. v1 3/4" = 1'-011 LADDER RACK FIBER TYPICAL 48 PORT PATCH PANEL - 2U PROVIDE AS REQUIRED VERTICAL CABLE MANAGEMENT i 0 0 0 0 ©o © 0 9 0- 9 NNNN NNNN • SECURITY PUBLIC COORDINATE WITH IT N N 8 N CABINET ADDRESS PERSONNAL FOR A CABINET RACK ARRANGEMENT ,CTIVE;/' /, TERMINATION LECTRON►C :QUIPMENT DATA, AND VOICE �� RACK UNINTERRUPTIBLE UPS UPS POWER SUPPLIES TYPICAL RISER CABLES BY TC CONTRACTOR FROM THIS MDF TO EACH IDF 12 STRANDS ARMORED - PLENUM RATED OM3 501im/125µm MULTIMODE FIBER OPTICS 24 STRANDS ARMORED - PLENUM RATED OM3 50µm/125µm SINGLEMODE FIBER OPTICS, FIBER TERMINATION SOLUTIONS SHALL BE LC -TYPE VOICE RISER 25 PAIR INDOOR/OUTDOOR - PLENUM RATED CAT5E COPPER RUN AS ONE (1) 25 PAIR CABLE -rvr% ri rvATWNKI r,C 7M I=rnnnnnl Inur:ATInN ROOM "TR" WITH 2 RACKS AND 2 CAB 1 1 1 . L I_ 1_ v 3/411 = 1'-011 VIDEO DISTRIBUTION FIELD CATV TAPS AND SPLITTERS FOUR (4) 4" EMT FROM THE STREET (VOICE, CATV, FIBER, SPARE) EXTEND 24" ABOVE FLOOR SEAL AND CAP PROPERLY SEE DETAIL 6/304 .EVATIONS ARE ONLY DIV 26 TO PROVIDE (4) L630R, 'IAMMATIC SENTATION REFER AND (4) L5-30R, AND (4) L5-20R ►INATE WITH THE TWISTLOCK RECEPTACLE ON 3 REPRESENTATIVE IN SIDE RAIL OF LADDER RACK. , TO PROVIDE ION OF RACKS AND )NTAL WIRE MANAGERS _DED FOR TOTAL 'ITY OF DROPS PROVIDE MINIMUM (3/4"x8'-0"X4'-0") A/C QUALITY VOID FREE, FIRE RATED PLYWOOE BACKBOARDS VERTICLE INSTALL STARTING Al 6"A.F.F., ON ALL WALLS. PAINT ALL SIDES WITF TWO COATS OF MATTE GREY (OF COORDINATE COLOR WITH ARCHITECT) FIRE RETARDANT PAIN, (MASK NOT TO PAINT THE FIRE TREATEC LABELING ON THE PLYWOOD PROVIDE QUAD RECEPTACLE! MOUNTED 6'-0" APART ALON( PERIMETER OF ROOF THIS ELEVATIONS ARE ONLY A DIAGRAMMATIC REPRESENTATION REFER AND COORDINATE WITH THE OWNER REPRESENTATIVE IN ORDER TO PROVIDE LOCATION OF RACKS AND HORIZONTAL WIRE MANAGERS AS NEEDED FOR TOTAL QUANTITY OF DROPS 1. VOICE CABLING SHALL BE INSTALLED IN SEPARATE RACK/RACKS, STARTING AT THE LEFT -MOST RACK AS VIEWED FROM THE FRONT OF THE RACKS 2. DATA CABLING SHALL BE INSTALLED IN SEPARATE RACK/RACKS, STARTING TO THE RIGHT OF THE VOICE RACK, EXCEPTION: IN BUILDING MDFS, LEAVE THE LEFT -MOST RACK EMPTY EXCEPT FOR FIBER LIUS AND START ONE RACK TO THE RIGHT FOR VOICE TERMINATIONS 3. NO MORE THAN 288 DROPS TWO DATA R C S W WITH A TOTAL OF EIGHT PATCH PANELS, THE LEFT DATA RACK WILL DROPS PANELS, 48 PORTS EACH. FILL RACKS UP TO 288 DROPS BEFORE PLACING ANY HAVE SIX PATCH PANELS AND THE RIGHT EXAMPLE: IF A CLOSET HAS DATA RACK WILL HAVE TWO. 4. FIBER LIUS SHALL BE PLACED AT THE TOP OF THE LEFT -MOST RACK IN THE CLOSET. 5. ALL STRUCTURED CABLE IN SUPPORT OF THE WIRELESS ACCESS POINTS OR (WAP'S) SHALL BE INSTALLED UTILIZING A 24 PORT PATCH PANEL IN THE LEFT MOST RACK LOCATED AFTER THE BLANK SPACE LEFT BY THE LIU. 6. ON THE WALL FIELD, 110 BLOCKS SHALL BE INSTALLED IN THE FOLLOWING ORDER FROM LEFT TO RIGHT: 110 BLOCK FOR DEMARC EXTENSION, 110 BLOCK REACHING TO MDF VOICE RACK, 110 BLOCKS TERMINATING RISER(S) TO IDF(S). 7. IT MUST REVIEW AND APPROVE PLACEMENT OF OTHER EQUIPMENT IN RACKS, CABINETS, OR ON WALLS PRIOR TO INSTALLATION. 8. ALL OPTICAL FIBER TERMINATION SOLUTIONS SHALL BE LC -TYPE. 9. THE 25 PAIR RISER CABLE SHALL TERMINATE ON A 24-PORT 1 U HIGH -DENSITY PATCH PANEL IN THE IDF AND ON A 110 BLOCK ON THE WALL FIELD, LABELED ACCORDINGLY, IN THE MDF. 10. DATA CABLING SHALL BE TERMINATED AT THE TOP OF THE LOCATION WITH WHITE JACKS. 11. VOICE CABLING SHALL BE TERMINATED THE BOTTOM OF THE LOCATION WITH BLACK JACKS. 12. WIRELESS ACCESS POINTS (WAP), SECURITY CAMERAS, AND TIME CLOCKS (IF APPLICABLE) SHALL BE TERMINATED IN THE CENTER OF THE LOCATION USING YELLOW JACKS. ABELED WITH THE ROOM NUMBER AND SEQUENTIAL LETTERS STARTING WITH "A" (E.G. THE FIRST THREE DA TA 13. LABELING: DATA AND DROPS SHALL BE L DROPS IN ROOM 201 WOULD BE LABELED ABE 201B, AND 201C). SKIP THE LETTER C ER "V". IF A ROOM HAS MORE THAN TWENTY-FIVE (25) DATA DROPS, LABEL THE 201ATWENTY-SIXTH (26TH) AS XXXAA, THE TWENTY-SEVENTH (27TH) AS XXXAB, 14. LABELING: VOICE DROPS SHALL BE LABELED WITH THE ROOM NUMBER AND THE LETTER "V" (E.G. THE TELEPHONE DROP IN ROOM 128 WOULD BE 128V). IF THERE ARE MULTIPLE VOICE DROPS IN ONE ROOM, LABEL THEM XXXV, XXXV1, XXXV2, ETC. 15. LABELING: WIRELESS ACCESS POINTS (WAP) SHALL BE LABELED WITH THE ROOM NUMBER AND THE LETTERS "WAP" (E.G. THE WIRELESS DROP IN ROOM 128 WOULD BE 128WAP). IF THERE ARE MULTIPLE VOICE DROPS IN ONE ROOM, LABEL THEM XXXWAP, XXXWAPI, XXXWAP2, ETC. 16. IT REQUIRES THAT ALL NON-IP TELEPHONE AND NON-STANDARD DATA SERVICES BE SERVED BY DEDICATED CABLE DROPS TO THE NEAREST IDF OR HOME RUN TO THE MDF AS FOLLOWS: 17. THE FOLLOWING ANALOG VOICE SERVICES ARE PROVISIONED BY IT AND SHALL BE SERVED BY VOICE -ONLY OR STANDARD DESK DROPS (TERMINATED AT THE OF OR MDF IN PATCH PANEL PORTS): 20. THE FOLLOWING CRITICAL SERVICES SHALL BE SERVED BY DEDICATED VOICE -ONLY DROPS HOME RUN TO THE MDF (TERMINATED IN A 110 BLOCK ON THE TELCO WALL BACKBOARD): • SECURITY SYSTEM INTERFACE (WHETHER DIAL CIRCUIT OR DEDICATED LEASED CIRCUIT) • FIRE ALARM SYSTEM MONITORING INTERFACE (NOTE: FOR SYSTEM TROUBLE REPORTING) • ELEVATOR EMERGENCY PHONE (CONDUIT IN MECHANICAL ROOMS, THROUGH TO THE ELEVATOR MACHINE) • GENERATOR GENERAL NOTE: ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT TO SCALE (N.T.S.) THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. DIV 26 TO PROVID (5)-4" CONDUIT SLEEVE INTO CORRIDO WITH BUSHING ON BOT ENDS PROVIDE FIR STOPPING TYPICA CABLE RADIUS DROP/WATERFALL -nA1n ON AT FA(H VFRTICLE CABLE PROVIDE VENTILATION OR AIR CONDITIONING TO MAINTAIN THE FOLLOWING CONDITIONS 24 HOURS PER DAY, 365 DAYS PER YEAR: TEMPERATURE: 64" TO 75" RELATIVE HUMIDITY: NON -CONDENSING MINIMUM VENTILATION RATE: 1 AIR CHANGE PER HOUR PRESSURIZATION: POSITIVE 17nn A Orman IT 1 1 F PI ANI `1." - - 1/2" = 1'-011 )S ARMORED SINGLEMODE )S ARMORED MULTIMODE ICS, VOICE RISER ARMORED kT5E COPPER RUN AS ONE (1) kBLE TO MDF DATA 1107F FUNDING Y E.C. MENT RACK WITH FAL AND VERTICAL WIRE 4ENT FOR FIBER, DATA ION AND ELECTRONIC qT. TYP. OF (3) ERMINATION OP OF TO BE 66" A.F-.F. 3" D-RINGS i AT EVERY 6" i THE TOP OF )ARDS 'ED LOCKABLE CABINET TO HOUSE >URVEILLANCE SYSTEM, ACCESS DL INTRUSION HEAD END [ENT 3INET )N DETECTION ON MODULES _LD CONTROL :LD QUAD RECEPTACLES :D 6'-0" APART ALONG ER OF ROOM LADDER RACK BY E.C. TO IT HORIZONTAWERTICAL ERHEAD CABLE =MENT f0 ELECTRICAL DRAWINGS 1 r1r AAC PROVIDE QUAD RECEPTABLES MOUNTED 6-0" APART ALONG PERIMETER OF ROOM MOUNT QUAD RECEPTACLES ON WALL AT 44" A.F.F. TYPICAL IDF I L. 24 STRANDS ARMORED SINGLEMODE 12 STRANDS ARMORED MULTIMODE FIBER OPTICS, VOICE RISER ARMORED 25 PAIR CAT5E COPPER RUN AS ONE (1) 25 PAIR CABLE TO MDF cnn orlrGn InF qnF PI AN 1/2" PROVIDE MINIMUM (3/47x4'-0"X8'-0") A/C QUALITY, VOID FREE, FIRE RATED PLYWOOD BACKBOARDS VFRTICLE INSTALL STARTING AT 12"A.F.F., ON ALL WALLS. PAINT ALL SIDES WITH TWO COATS OF MATTE GREY (OR COORDINATE COLOR WITH ARCHITECT) FIRE RETARDANT PAINT (MASK NOT TO PAINT THE FIRE TREATED LABELING ON THE PLYWOOD) LLJ [;j u u (4) 4" SLEEVES �— FOUR (4) 4" SLEEVES TO PASS THRU ALL CABLINGFROM THE O FIRST FLOOR SEAL AND CAP PROPERLY SEE DETAIL 6/304 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 W � Q � r o z �Wo � WH U x zoo H o � a w e U 0 0 c 9 Moody Road Building D Suite 18 0 Enfield, CT 06082 T.860-341-1206 rn F.860-239-1358 0 www.gtc.us.com a 0 3rc.�r az iu W JOSEPH J NORTON M REG. No. 202538R EXPIRES 12-31-20 moser pilon nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE TELECOMM ENLARGED PLAN AND DETAILS DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. E z U O i a_ z 1 IVI GVJ T301 T301 c E z U 0 a. NOTE: ALL OPENINGS TO BE REFILLED AROUND CONDUITS USING APPROVED GROUT MATERIAL PER SPECIFICATIONS TYPICAL 4" DIA. CONDUIT WALL PENETRATION DETAIL N_T-S_ NUMBER OF HANGER RODS SHALL BE REQUIRED FOR PROPER SUPPORT (MIN. OF 2) ONLY ONE IS SHOWN FOR CLARITY. UNISTRUT SUPPORT NUT (TYP.) CONDUIT (TYP.) UNISTRUT UNI-CLIP CLAMP, USE FOR ELEC. AND TELECOMMUNICATION CONDUIT UNISTRUT 40mm (1-5/8") X 40mm (1-5/8") CHANNEL SUPPORT (TYP.) nln-rF�• 1. SUPPORT CHANNEL LENGTH SHALL NOT BE DETERMINED UNTIL ALL PIPING, CONDUIT, ETC. TO BE SUPPORTED IS COORDINATED. 2. SUPPORT CHANNEL SPACING SHALL BE NO MORE THAN 10'-0". 3. UNISTRUT AND CONDUIT INSTALLATION MAY BE REVERSED. TYPICAL TELECOMMUNICATIONS SUPPORT ABOVE CEILING N.T.S. 4" CONDUIT STRAP TO KINDORF TYP. CUSTOM DESIGNATOR CONTRACTOR TO COORDINATE PER OWNER/ENGINEER LABELING SCHEME REQUIREMENTS FOR OWNER ROOM NUMBERING. O V-'#®®®®® ®®®[EXEC XXXXXX U O (�11I1�11 P!DIfl�lft�l�f�!� I Ifl�9llfi If�9IfL�� (®®®[EXEC I lIT,I( I[ If llf 1pr1@!gIT71fi�l� 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 l 0JtuUUL_ffAu Ulul f A f Jl _ JL� 1 Ltt_jl ft 1LfF_1L!F_lUU ULft_JUUUL9 1 fin F71!-_R ll(11Irm fL�9l�lf�9l�!DIfL�lfi!�D [�If�II[�I�9 �I[ (�I�9I�I�9I�If�!� 0 n 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46 47 48 n O TYPICAL 48 PORT PATCH PANEL N T R HORIZONTAL WIRE MANAGEMENT ABOVE AND BELOW EACH PATCH PANEL. SECURE CABLING WITH HOOK AND LOOP TYPE VELCRO STRAPS. VERTICAL WIRE MANAGEMENT AS SHOWN IN THE RACK ELEVATION DETAILS, SECURE CABLING WITH HOOK AND LOOP TYPE VELCRO STRAPS THIS ARRANGEMENT IS TYPICAL FOR THE FRONT AND REAR OF THE RACK. PROVIDE STRAIN RELIEF AT ALL CABLE CONNECTIONS. EQUIPMENT RACK WIRING MANAGEMENT DETAIL N.T.S. PRIMARY PATHWAY - NEW PULLBOX SIZING/CONNECTION DETAIL ACCEPTABLE INSTALLAT OMNACCEPTABLE INSTALLA' METHODS METHODS NOTES: MANUFACTURER'S PORT DESIGNATOR TYPICAL OF 48 PORT PATCH PANEL. =ME FOR SELECTING PRIMARY PATHWAY PULLBOX SIZE MINIMUM SPACE REQUIREMENTS IN PULLBOXES HAVING (1) CONDUIT EACH IN OPPOSITE ENDS OF THE BOX CONDUIT TRADE SIZE WIDTH LENGTH DEPTH WIDTH INCREASE FOR ADDITIONAL CONDUIT MM IN MM IN MM IN MM IN MM IN 27 1 102 4 406 16 76 3 51 2 35 1-1/4 152 6 1 508 20 76 3 76 3 41 1-1/2 203 8 686 27 102 4 102 4 53 2 203 8 914 36 102 4 127 5 63 2-1/2 254 10 1067 42 127 5 152 1 6 78 3 305 12 1219 48 127 6 152 6 91 3-1/2 305 12 1372 54 152 6 152 6 103 4 381 15 1524 60 203 8 203 8 A. A PULL BOX SHALL BE INSTALLED IF (1) LENGTH IN THE PATHWAY IS OVER 100 FEET, (2) QUANTITY OF MORE THAN TWO 900 BENDS, AND (3) IF THERE IS A REVERSE BEND IN THE RUN. B. PULLBOXES SHALL BE INSTALLED IN AN AREA THAT IS READILY AVAILABLE ACCESSIBLE AND IS IMMEDIATLY ABOVE A SUITABLE MARKED PANEL. COORDINATE MARKING OF PANELS WITH OWNER. C. PROVIDE LABELING PER DIV. 27 0000 PULLBOX SIZING/CONNECTION DETAIL N.T.S. NOTES: 1. THIS ILLUSTRATION DEPICTS THE FRONT VIEW OF THE OUTLET/CONNECTOR/PATCH PANEL. 2. PIN/PAIR ASSIGNMENT FOR ALL DEVICES SHALL CONFIGURE TO ANSIITIAIEIA 568-B. PAIR 1 - WHITE-BLUEIBLUE T1 R1 PAIR 2 +► WHITE-ORANGE/ORANGE T2 R2 PAIR 3 ► WHITE-GREEN/GREEN T3 R3 PAIR 4 ► WHITE-BROWN/BROWN T4 R4 T-568B WIRING SCHEME DETAIL PAIR 3 PAIR 2 PAIR 1 PAIR 4 n n ) n T2 R2 T3 R1 T1 113 T4 R4 (VIEW FROM FRONT OF JACK) vrwUivLill vv i nv MAIN TELECOMMUNICATIONS GROUNDING BUSBAR (MTGB NI T C XMTGB TYPICAL LABEL FOR "MTGB" "XXXX" IDENTIFIES THE SPACE, COORDINATE IDENTIFICATION OF SPACE WITH THE DRAWINGS AND THE OWNERS REPRESENTATIVE TYPICAL BONDING CONDUCTOR CONNECTORS SHALL BE UL LISTED COMPRESSION TWO -HOLE LUGS COPPER UL LISTED TMGB MINIMUM 1/4" THICK X 4" W X 20" L WITH TWO MOUNTING BRACKETS AND INSULATORS. MANUFACTURERS: CHATSWORTH, ERICO, HOMACO & PANDUIT COORDINATE EXACT LOCATION IN FIELD TYPICAL MOUNTING BRACKET SECURED TO PLYWOOD ON WALL DETAIL NOTES FOR GROUNDIKIIG & BONDI VG 1. REFER TO GROUNDING AND BONDING DIVISION 26 SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2. PROVIDED 2"C SLEEVE PATHWAY AT EACH FLOOR AND WALL PENETRATIONS FOR THE TELECOMMUNICATION BONDING BACKBONE (TBB). COORDINATE PROPER METHODS FOR PENETRATIONS WITH FIRESTOPPING AS REQUIRED PER DIVISION 07 SPECIFICATIONS. 3. BONDING CONDUCTORS SHALL BE #3/0 AWG COLOR GREEN INSULATED COPPER CONDUCTOR OR SIZED PER "BONDING CONDUCTOR SIZING CHART" BELOW (ANSI J-STD-607-A) IN PATHWAY. 4. FASTENING BONDING CONNECTOR TWO -HOLE LUGS TO ALL BUSBARS SHALL BE CLEANED AND APPLY A COPPER ANTI -OXIDANT TO THE CONTACT AREA OF BOTH THE CONNECTOR LUG AND THE BUSBAR. 5. BONDING CONDUCTORS AND BUSBARS SHALL BE LABELED WITH IDENTIFICATION IN ACCORDANCE WITH THE REQUIREMENTS OF ANSI/TIA/EIA-606-A. 6. BONDING CONDUCTORS SHALL BE LABELED WITH IDENTIFICATION LABEL NOTED BELOW AND SECURED WITH CABLE TIE TO EACH CONDUCTOR. (ANSI J-STD-607-A) IF THIS CONNECTOR OR CABLE IS LOOSE OR MUST BE REMOVED, PLEASE CALL THE BUILDING TELECOMMUNICATIONS MANAGER". 7. CONTINUITY TESTING MEASUREMENTS OF THE GROUNDING RESISTANCE TO NOT EXCEED 0.1 OHM BETWEEN: A. EACH TGB AND THE NEAREST GROUNDING ELECTRODE. C. EACH TGB AND PATHWAY(S), RACK(S), CABINET(S) AND APPLICABLIEQUIPMENT. 8. COORDINATE AND CONFIRM THE TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) INSTALLATION AT THE ENTRANCE FACILITY (EF). 9. COORDINATE AND CONFIRM THE BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) CONNECTION TO THE BUILDING GROUNDING ELECTRODE FROM THE TGB AT THE EF. 10.000RDINATE AND CONFIRM THE BCT TO NEAREST BUILDING METALLIC DOMESTIC COLD WATER PIPE CONNECTION, IF APPLICABLE FROM THE TGB AT THE EF. TYPICAL BONDING CONDUCTOR CONNECTORS SHALL BE UL LISTED COMPRESSION TWO -HOLE LUGS 3 ,) e e O O e O O B ® ® O 0 ® O 0\ � 0 �-��® 0 O O\\�0 0 O O O�\�0 O O O O O O O O O 0 XXXX-MTGB COPPER UL LISTED TGB MINIMUM 1/4" H X 4" W X 20" L PER DIVISION 26 SPECIFICATIONS WITH TWO MOUNTING BRACKETS AND TYPICAL LABEL FOR INSULATORS. ACCEPTABLE TELECOMMUNICATIONS MANUFACTURERS: CHATSWORTH, ERICO, GROUNDING BUSBARS PER DIVISION 26 HOMACO & PANDUIT SPECIFICATIONS. "XXXX" IDENTIFIES THE SPACE, COORDINATE IDENTIFICATION OF SPACE WITH PLANS AND OWNER (5'1 MAIN TELECOMMUNICATIONS GROUNDING BSBAR (MTGB) N.T.S. FIRE RATED FLOOR -CEILING GROUT EMT SLEEVE FIRESTOPPING CABLES SLEEVE WITH BUSHING SHALL EXTEND MIN. 1" FROM FLOOR -CEILING MOUNTING HEIGHT 9'-6" AFF. LOCATION ON PARTIAL PLANS. COORDINATE IN FIELD TYPICAL MOUNTING BRACKET SECURED TO PLYWOOD ON WALL PER DIVISION 26 SPECIFICATIONS GROUNDING BACKE TELECOMMUNICATION GROUNDING BUSBAR (TGB III IBOVDIVG COVDUCOR SZVGCriAR LENGTH (FEET) SIZE (AWG) LESS THAN (<)13' # 6 14'-20' 21'-26' 27'-33' 34' - 41' 42'- 52' 53' - 66' GREATER THAN (>) 66' #4 #3 #2 # 1 # 1/0 # 2/0 # 3/0 OBONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) TO NEAREST BUILDING STEEL STRUCTURE, IF APPLICABLE. UTILIZE EXOTHERMIC WELDING CONNECTION TO BUILDING STEEL. ,1 BUT TO NEAREST BUILDING ELECTRICAL PANELBOARD GROUND BAR. UTILIZE LISTED COMPRESSION TWO -HOLE LUGS TO PANELBOARD GROUND BAR. 0TELECOMMUNICATION BONDING BACKBONE (TBB) FOR GROUNDING EQUALIZER (GE), 3 IF APPLICABLE. /0 TBB THAT INTERCONNECTS THE TGB (IF PRESENT AT THE ENTRANCE FACILITY) TO J BUILDING GROUNDING ELECTRODE. J0BCT TO TELECOMMUNICATIONS CABLE TRAY(S), LADDER RACK(S), PATHWAY(S), EQUIPMENT RACK(S), EQUIPMENT CABINET(S) AND APPLICABLE EQUIPMENT. DAISY CHAINING OF BCT AT RACKS IS NOT ACCEPTABLE. EACH RACK IS TO HAVE A BCT TO A COMPRESSION LUG TAP TO THE DEDICATED HOMERUN BCT BACK TO THE TGB. SEE DETAILS. EQUIPMENT RACK AND CABINET GROUND BARS PROVIDE SOLID COPPER GROUND BARS DESIGNED FOR MOUNTING ON THE FRAMEWORK OF OPEN OR CABINET -ENCLOSED EQUIPMENT RACKS WITH MINIMUM DIMENSIONS OF 4 MM THICK BY 19 MM WIDE (3/8 INCH X 3/4 INCH). GROUND TERMINAL BLOCKS AT "" P' UIPf-l"T A 01 INTING 1 OCATION /1- l'. /%I HIV T EQUPIVIEN 1 IVIVUN I NN LOCATION- I ION (E.G. BAI,KBQARDJ AND HINGED COVER ENCLOSURES) WHERE RACK -TYPE GROUND BARS CANNOT BE MOUNTED, PROVIDE SCREW LUG -TYPE TERMINAL BLOCKS. TYPICAL BONDING CONDUCTOR CONNECTORS SHALL BE UL LISTED COMPRESSION TWO -HOLE LUGS. A MINIMUM OF TWO CRIMPS ON A LONG BARREL COMPRESSION LUG U (3) B e 0 O B O 0/�"���i� e 0 O B O 0�\� XX-TGB COPPER UL LISTED TGB MINIMUM TYPICAL LABEL. FOR 1/4" H X 2" W X 12" L PER TELECOMMUNICATIONS GROUNDING DIVISION 26 SPECIFICATIONS WITH BUSBARS PER (DIVISION 26 TWO MOUNTING BRACKETS AND SPECIFICATIONS. "XX" IDENTIFIES THE INSULATORS. ACCEPTABLE SPACE, COORDINATE IDENTIFICATION MANUFACTURERS: CHATSWORTH, OF SPACE WITH PLANS AND OWNER ERICO, HARGER, HOMACO & PANDUIT. UTILIZE BUSBAR MANUFACTURER FOR COMPRESSION TWO -HOLE LUGS 2 TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) N.T.S. U l�l1A 1P\I IIT BUSBAR LABEL COORDINATE EXACT LOCATION ON PARTIAL PLANS. MOUNT BUSBAR ABOVE LADDER RACK. COORDINATE IN FIELD TYPICAL MOUNTING BRACKET SECURED TO PLYWOOD ON WALL PER DIVISION 26 SPECIFICATIONS LING 1.1 NG CEILING REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 � o 9 Moody Road d Building D Suite 18 Q Enfield, CT 06082 T.860-341-1206 0 F.860-239-1358 0) www.gtc.us.com N CO Bkv GO w W JOSEPH J NORTON REG. No. 202538R b EXPIRES 12-31-20 a moser pilon nelson architectc. 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE DETAIL TECHNOLOGY DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. N.T.S. HORIZONTAL FIRESTOPPING DETAIL N.T.S. VERTICAL FIRESTOPPING DETAIL N.T.S. T302 a� E Z3 z U N O i z n TO MAINTAIN PROPER BEND RADIUS OF CABLES (TYP) 3 TYPICAL LADDER RACK CONNECTION DETAIL �T303 N.T.S. TELECOMMUNICATION CABLES PER RISER DIAGRAM LADDER RACK 1 1/2" METAL FRAMING CHANNEL ANCHORED TO WALL 4'-0" OC WALL SECURELY ANCHOR LADDER RACK FOOT TO FLOOR (TYP) VERTICAL LADDER RACK INSTALLATION DETAIL (IF APPLICABLE N.T.S. TERMINATE CONDUIT ABOVE ACCESSIBLE FINISH CEILING OR IN UNFINISHED SPACE PLASTIC BUSHING FINISH CEILING NOTES AT EACH OUTLET LOCATION SHOWN ON THIS DRAWING THE ELECTRICAL CONTRACTOR SHALL PROVIDE ROUGH -IN IN ACCORDANCE WITH THIS DETAIL COORDINATE LOCATIONS WITH DUPLEX RECEPTACLES RECESSED FLOORD WIREMOLD 880 OMN THREE GANG SHALL CAST IRON FLOOR B WITH BRASS CARPET TILE FLANG OR EQUAL SEE ELEC DWGS 00 00 0 90 DEG. SWEEP ELBOW 1 1/4" EMT RACEWAY TYPICAL OR UNLESS OTHERWISE NOTED (U.O.N.) FINISH CEILING PLASTIC I TERMINATE ACCESSIBLE FINISH CEILING OR IN UNFINISHED SPACE :R 1SED ERE SECTS USE HOOK AND LOOP STRIPS TO SECURE CABLES TO LADDER RACK (TYPICAL FOR ALL CABLES) VERTICAL WALL BRACKET, (TYPICAL OF 2 AT EACH FRAMING CHANNEL LOCATION) LADDER RACK FOOT KIT BONDING BUSHING (TYP) FLOOR SLAB BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT) CONNECTOR (TYP) PATHWAY SLEEVES OR CONDUITS THOUGH FLOOR SLAB. SEE PARTIAL PLANS FOR SIZE, LOCATION, AND QTY. co 90 DEG. SWEEP ELBOW 1 1/4" EMT RACEWAY TYPICAL OR UNLESS OTHERWISE NOTED (U.O.N.) FLUSH SINGLE GANG U.O.N. OUTLET BACK BOX WITH PLASTER RING. NOTES AT EACH OUTLET LOCATION SHOWN ON THIS DRAWING THE ELECTRICAL CONTRACTOR SHALL PROVIDE ROUGH -IN IN ACCORDANCE WITH THIS DETAIL COORDINATE LOCATIONS WITH DUPLEX AND QUAD RECEPTACLES SEE ELECTRICAL SPECIFICATIONS SECTION 26 CONNECTION HARDWARE, PARTS AND PIECES ARE TO BE OF THE SAME TYPICAL LADDER RACK INSTALLED ABOVE EQUIPMENT RACKS DETAIL NOTES: 1. CABLE TRAY SYSTEMS ARE TO BE USED AS REQUIRED, CABLING SUPPORT REQUIREMENTS SHALL COMPLY WITH ANSI/TIA/EIA. OTHER ALTERNATIVES MUST BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. 2. CABLE TRAYS SHALL BE MOUNTED ABOVE ACOUSTICAL TILE CEILING IN CORRIDORS, WITH CENTER SUPPORT HANGER ASSEMBLIES. CABLE TRAYS SHALL BE SUPPORTED WITH UNISTRUT AND THREADED RODS. THREADED RODS SHALL BE SECURELY FASTENED TO THE STRUCTURE ABOVE. SUPPORT CABLE TRAYS AT 6'-0" INTERVALS AND AS REQUIRED AND RECOMMENDED BY THE CABLE TRAY MANUFACTURER BASED ON MAXIMUM FILL CAPACITY OF CABLES IN TRAY. 3. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR MAX LOADING, APPLICATION REQUIREMENTS, AND SECURING TO STRUCTURE. 4. ALL CABLE SUPPORTS SHALL BE SPECIFICALLY MANUFACTURED TO SUPPORT HIGH SPEED COMMUNICATION CABLES. ❑o❑o o❑ —❑ TYPICAL CABLE TRAY DETAIL (IF APPLICABLE N.T.S. I Y MAL 4-I'AIK U I F UA I bjUM CABLE WITH VELCRO WRAPS ON BOTH SIDES OF J-HOOK PER DIVISION 27 SPECIFICATIONS. PLASTIC TIE WRAPS ARE NOT ACCEPTABLE ON ANY UTP CABLE. CABLE TRAY PER DIVISION 26 SPECIFICATIONS "TAGGERED SPACING OF -HOOKS - 5' MAX. YPICAL CABLE HOOK PER IVISION 27 PECIFICATIONS. CABLE LADDER RACK CABLE RADIUS DROP/WATERFALL J-BOLT CLIP KIT AUXILIARY FRAMING CHANNEL KIT LADDER RACK MOUNTING PLATE LADDER RACK (TYPICAL) EQUIPMENT RACK (TYPICAL) V CRI I-n/_x VVIRC MANAGER (TYPICAL) CENTER HANGER ASSEMBLIES CABLE TRAY II II II II II II II II 11�9 v�V JUMPER WITH MOUNTING HARDWARE GENERAL NOTE: ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT TO SCALE (N.T.S.) THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE SUITARILITY OF THFSF npAUUINGC PnP THE SPECIFIC; APPI Ir'ATInnI IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. LADDER RA, (TYPICAL) BONDING CONDUCTOR CONNECTORS SHALL BE UL LISTED COMPRESSION TWO -HOLE LUGS. A IVIIIVIIVIIJ OF TWO CRIMPS ON A \ LONG BARREL COMPRESSION LUG, 6 AWG COPPER GROUND WIRE REMOVE PAINT FROM LADDER RACK SURFACE BEFORE ANCHORING (TYPICAL) TELECOMMUNICATIONS LADDER RACK GROUNDING STRAP DETAIL IV,I,ti- BICSI/MANUFACTURER INSTALLATION NOTES: I. PRO "DE VCLCKU CABLt WRAPS MINIMUM 12" (`C�ITCDC IAI \/CDTI(AI lnnoc C-TYPE COMPRESSION T RACK GROUND BAR STYLE GROUND JUMPE U m n11.......T RACK VIBE TYPICAL) DLE DP BLE CAL) REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 O O � � O w A w O (O L� V1 U I Q + ! o I o i � U 9 Moody Road rz Building D Suite 18 c� Enfield, CT 06082 T.860-341-1206 F.860-239-1358 c a www.gtc.us.com A D�sT &NG Bicsi � 2 u- JOSEPH J NORTON m REG. No. 202538R 2 EXPIRES 12-31-20 moser pilon nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE DETAIL TECHNOLOGY DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. 11 TYPICAL FB CONDUIT CROSSSECTION DETAIL T303r N.T.S. - - 10 TYPICAL CONDUIT DETAIL T303) N.T.S. TYPICAL VOICE/DATA J-HOOK DETAIL N.T.S. GROUND JUMPER N.T.S. RACK GROUNDING DETAIL_ N.T.S. T303 E z U a� 'o z REVISIONS UNISTRUT PROJECTOR SUPPORT BY G.C. CONFORMED SET MARCH 22, 2019 ANCHOR TO SLAB OR MOUNT 9-1/8" TO OVERHEAD STEEL 1/2" THREADED ROD i CHIEF CMA110 8" ADAPTER BEAM STRUCTURE S " CHANNELED UNISTRUT PLATE BY AUDIO VISUAL SUPPORT CONTRACTOR 0 0 STRUCTURE ABOV -- GENERAL CONSTRUCTION NOTE: 0 0 �'�� PLENUM RATED CABLE TO (3) 2" CONDUIT FROM CONTROL �- 13-1/8" 1/2" THREADED ROD 0 0 0 0 • .. a BE PULLED FOR THIS PROJECT ROOM W/BUSHING &PULL STRING PFC-A FEMALE PIPE COUPLER e O 0 - .0 e 0 0000000000000000000 0 FOR JOINING MALE TO MALE PIPE DALITE LARGE TENSIONED ADVANTAGE ELECTROL 0 0 6-1/2 " 0 e GYPBOARD ENCLOSURE0 079 0 0 �J NPT 1-1/2" DIA. PIPE THRFAn.q AT RnTH FNI�R Da-LITE 40973 SINGLE '- hAnrrnD I n%A/ \/nI TAl-C Da-LITE 21873 TENSIONED 0 0 0 0 BY A/V CONTRACTOR ADJUST LENGTH FOR SCREEN BLACK DROP M OTO, i LV VV V VL I1-IUL e LARGE CONTROL SYSTEM ADVANTAGE DELUXE ELECTROL HDTV 16:9 DISPLAY HD I] 0 0 0 1/2" THREADED ROD, 30" TYP. (4X) C�� MIDDLE ATLANTIC CEILING TILE ALIGN PROGRESSIVE 0.9 DIAC.nNAI SORFFN R17F- 29R" TOP VIEW OF SUPPORT SIDE VIEW OF SUPPORT ERK-4425-AV EQUIPMENT RACK REF. SPECIFICATION BILL OF HEIGHT EQUALS: 146" MATERIALS FOR MORE DETAILS STATE PROJECT NO. WITH EQUALS 260" PULL RED FOR THE O(3A2" CONDUITS (2) DUPLEX OUTLETS 132-0089 N PROJECTOR MOUNTING FROM CONTROL ROOM PHASE 2 OF 5 INTERFACE TO ROUTE ALL AV AND SOUND 1-GANG BOX FOR OX/ AI Into \/101 IAI DUPLEX ELECTRICAL �� DT MUUI%J VIOUI-%L OUTLET CONTRACTOR o PROJECTOR nlr+wtnl 16/11'111.111 AIC\A/nDI/INIP_ IVLYYVIIIxIIVVI JIu1VHL VVIrtIIVuILI (BY TELECOM SEE FLOOR PLAN FOR o�) SYMBOL) BY AUDIO VISUAL PROJECTOR SIGNAL CONTRACTOR 18" AND 711 POWER CABLES III II FINISHED FLOOR L P P D p D P ��. 4 `� PROJECTOR MOUNTING DETAIL 3 CAFETERIA AND GYM PLATFORM PROJECTOR SCREEN DETAIL 2 PROJECTOR UNISTRUT SUPPORT 1 PLATFORM RACK DETAIL F■•� `. T304) 6" = 1'-0" DETAIL IS SHOWN FOR REFERENCE ONLY T304 6" = 1'-O" DETAIL IS HOWN FOR REFERNCE ONLY SEE ARCH DWGS. FOR INSTALLATION T304 6" = 1'-O" DETAIL IS SHOWN FOR REFERENCE ONLY T304 6" = 1'-0" O MAnlrl DInMl Av — (2) 1-1/4" CONDUIT STUB ABOVE ACCESSIBLE CLG. INS FINISHED CEILING rHNCL uIOrLHT FLA I SI:REEN MUNI I OR CONNECTION OUTLET AVERAGE 52" DIAGONAL NETSELECT 30"H X 48" W 2 GANG IN -WALL ENCLOSURE 41_011 TILT TV WALL MOUNT SUPPORTS 52" v r v DA-LITE TENSIONED ADVANTAGE CEILING FLAT PANEL CEILING O DELUXE ELECTROL PROJECTION SCREEN DSP - ILL! rr N BUILDING STRUCTURE AJ O 'f 6-0" 1]3�DIAGONAL VIEW AREA Q U) - - e 'd �J M� w < W .. e • a a e W r 1 Q ALL DIMENSION TO LLI r C° AIRCRAFT CABLE TO STRUCTURE ABOVE 0 "VIEW BE ARE.A. FLVP 2 COORDINATED WITH ^ 0 AR�c TO RAL � V.I.F. A / A lf' CLC IV!'11 IIJIVJ I n DUPLEX POYY/ER OU I LE I FINISHED FLOOR 1 � FLOOR I J FLOOR CEILING 10.5587M5279 SPEAKER . CEILING TILE ^ ` 1 `/ � E•.,I C ii t J p P p D D b L D b D FLAT PANEL DISPLAY IN MAIN OFFICE 101 _ 0.1061 2.2963--� O (` 6 ) COMMUNITY D6 CEILING SPEAKER E-� 8 AV PROJECTION SCREEN DEVICE FRONT ELEVATION PLAN 7 DIGITAL SIGNAGE ENTRANCE AND PUBLIC CORRIDORS \T304 6" T304 6" = 1'-0" DETAIL IS HOWN FOR REFERNCE ONLY SEE ARCH ELEVATION FOR DIMENSIONS T3o4 3/8" = 1'-0" 940 v e w v rn 0 0 c s r, ti 9 Moody Road Building D Suite 18 0 Enfield, CT 06082 1 T.860-341-1206 a F.860-239-1358 c www.gtc.us.com N (6) i 150 J NORTON JOSEPH REG. No. 202538R • EXPIRES 12-31-20 • 4• moser pillon nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE DETAIL TECHNOLOGY GENERAL NOTE: ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT TO SCALE (N.T.S.) DATE 11/02/2018 THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR COPYRIGHT (c) CONSTRUCTION. APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE Moser Pilon Nelson Architects SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. DWG. NO. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. T304 EQUIPMENT WILL BE HOUSED IN THE RACK AT THE MDF ROOM MIDDLE \ ATLANTIC ERK-3525-AV CONFIGURE WITH ALL ACCESSORIES OR EQUAL \ I 1 LISTEN LT803-072 01 DENON DN30OZ (MOUNTS IN RACK IN LSS 1 CLOSET) 1 1 . g t 1 SAMPSON SWC99HQ8 HANDHELD WIRELESS 1 SAMSON SXD7000 AMPS ASSISTIVE LISTENING TRANSMITTER I I ;- 0 0 INTERFACE WITH 1 l�CLV OI V I Fill 1 SURE FROM10- LR-1, 1 1 SAMPSON SWC99HQ8 HANDHELD WIRELESS FIRE SYSTEM 1 1 ice ALARM SYSTEM PDS-2X315 SEQUENCED DUAL 15 AMP POWER STRIPi 1 6 EAR SPEAKERS C) 1 1 1 SAMSON SWC99BLM10 _ 1 ' SAMPSON SWC99BS E10 EARSET WIRELESS y U • I LR-200-072 MIDDLE ATLANTIC BELT PACK Q 8+ ` „ �r . •err RECEIVERS Q cfl - __-__._-- -- - _ - _ • J-DEC REIVIV I E N POWER SWITCH N I SAMSON SXD7000 AMPS _� I LEVEL COMMUNIT Y RP4/LC1 'K REMOTE VOLUME -- SELECTOR !'`VAANIAQII Inn 311 — 1'-011 SPEAKER TYPE SCHEDULE QTY DESCRIPTION MANUFACTURER MODEL r 8 SPEAKERS - MAINS - GYMNASIUM COMMUNITY R.5 66Z 2 MAIN LEFT & RIGHT - AUDITORIUM IP6-1122/96B 0 MAIN CENTER - AUDITORIUM SAMSON IP6-1152/94B "D" 0 SUBWOOFER - AUDITORIUM COMMUNITY IS6-215B "E" 0 FLOOR MONITORS - AUDITORIUM MX10B "F" 0 POWER MONITOR - AUDITORIUM - CONSOLE/CONTROL ROOM AURO D208 "G" 2 SPEAKER - INSTRUMENTAL MUSIC AND PLATFORM DS-8W "H" 4 WHITE SPEAKERS - CAFETERIA D6 PROCO MIC PLATE DENON DN30OZ BACKGROUND MUSIC FEED FROM MAIN LOBBY SYSTEM �► W- ' = OUT i e I�Ig 1 0000000000 0 0 � I 1 �►... d 1 ilia 4 PAGE OVERRIDE FOR PROGRAM MATERIAL WITH PAGING SIGNAL PRESETS: 1. GYM FLOOR ONLY 2. PLATFORM ONLY 3. ALL COMBINED ® 1 1 SAMSON SXD7000 AMPS 1 1 COMMUNITY RP4-LC1 DSP REMOTE PRESET/ LEVEL CONTROL 1GANG 0 L� I V S-DEC DECORA POWER ZI SWITCH - RACK - ON/OFF \ ------- ---------------------------------- DENON DN30OZ S-DEC & DECORA PANEL PD920R POWER STRIP I I I I I - - EAR SPEAKERS ASSISTIVE LISTENING BELTPACK RECEIVER I I i BDP-103 BLUE RAY SAMSON SWC99 HQ8 HANDHELD WIRELESS 0 Y SAMSON SWC99 HQ8 HANDHELD WIRELESS I NECKLOOPS I uo� uc� --------------------- rAPGTI=PIA 9 NTS AUX 1 STEREO IN 1 ZONE 2 LOGIC IN O J O W CDz r Z T Q 1 r U C\I Q Z J 00 Iz > w Il ------------ MIDDLE ATLANTIC EW R-16-22SD WALL MOUNTED RACK I I GENERAL NOTE: TYPE "A" i, IKAI IAIIT\/ n c �c_7 lwlVJIVIUN I T n.a-QVL SPEAKERS oil TYPE "A" COMMUNITY R.5-66Z SPEAKERS TYPE "A" f`nKAAdl InnTv R 5_667 IJVIVIIvIVIYI I SPEAKERS TYPE "A" CVIM1v1 i1v1I I R.5_667 SPEAKERS TYPE "B" COMMUNITY V2-3564W ON EITHER SIDE OF STAGE INTERFACE WITH CONTACT CLOSURE FROM FIRE/LIFE/SAFETY SYSTEM TO MUTE LOCAL SOUND AND PAGING/FOR AUDIO SYSTEM OVERRIDE --------------- LISTEN LT803-072 AN -C I (MOUNTS IN RACK) I �E=—DE)ao ASSISTIVE LISTENING AN -C TRANSMITTER , 1�1 ------------------ ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT TO SCALE (N.T.S.) THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. TYPE "H" COMMUNITY D6 WHITE SPEAKERS CEILING SPEAKERS TYPICAL OF 4 TYPE "L" COMMUNITY DP8-W WHITE SPEAKERS PENDANT MOUNTED TYPICAL OF 4 REVISIONS CONFORMED SET MARCH 22, 2019 STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 0 'ROW OV1 Tn � w o Wo W E� Z n A W � � 0 v N H � 9 Moody Road iiE Building D Suite 18 Q Enfield, CT 06082 11-1 T.860-341-1206 F.860-239-1358 c www.gtc.us.com N 0 o W JOSEPH J NORTON m S REG. No. 20253SR �;G? EXPIRES 12-31-20 moser pilon nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE LOCALSOUND RISER DIAGRAM AND DETAILS FOR REFERENCE ONLY DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects E z U 0 z a DWG. NO. T401 REVISIONS CONFORMED SET MARCH 22, 2019 CORRi^uno ® - - SPEAKERS. CLOCK CIRCUIT.---- - ROOM SPEAKERS. ®�'d SEPARATE HOMERUN FOR EACH SPEAKER. CORRIDOR SPEAKERS.-- - CLOCK CIRCUIT. ---- -- ROOM SPEAKERS. SEPARATE HOMERUN FOR EACH SPEAKER. PRIORITY MUTE TO GYM SOUND SYS. PRIORITY MUTE TO CAFETERIA SOUND SYS. PRIORITY MUTE TO CHORAL & BAND ROOM SOUND SYS. PRIORITY MUTE TO AUDITORIUM SOUND SYS. ®- -- -- -- PRIORITY MUTE TOMEDIA CENTER SOUND SYS. PRIORITY MUTE TO ALL LOCAL SOUND VENUES 25 PAIR ARMORED CABLE TO PBX LOCATED AT VOICE TERMINATION FRAME. CORRIDOR SPEAKERS. -0 CLOCK CIRCUIT. ROOM SPEAKERS. SEPARATE HOMERUN FOR EACH SPEAKER. TO INTRUSION ALARM CONTROL PANELTO FIRE ALARM CONTROL PANEL ANTENNA BLONDER TONGUE FM ---------- ON ROOF ANTENNA #BTY-2-FM 2" DIA. MAST ROOF I RG-6 COAX CABLE - ---- - --- rnRRinnRSPFAKFR.q _.. -- - -- -- - - -- - --► CLOCK CIRCUIT. ROOM SPEAKERS. SEPARATE HOMERUN FOR EACH SPEAKER. - --- -- CORRIDOR SPEAKERS. - - - CLOCK CIRCUIT. ROOM SPEAKERS. SEPARATE LJrlt, AC ni 1 N I r7f-M CAr1LI Cl=A V=) RUIVIERUIV FOR EACH SPEAKER. — --- CAFETERIA SPEAKERS. CORRIDOR SPEAKERS. CLOCK CIRCUIT. ROOM SPEAKERS. SEPARATE HOMERUN FOR EACH SPEAKER. FRONTROW SERVER/ INTERCOM/ INTERFACE WITH MASTER CLOCK HEADEND CATEGORY 3 CABLE CATEGORY 3 CABLE PA/INTERCOM TFI FPHQNF INITCRGArF- 0oR1 I- �tq_ - ITV 1 LI ll IIVL VlIU LL SYSTEM ��99 NOTE: REFER TO DIVISION 27 SPECIFICATION FOR EQUIPMENT INCLUDED IN THIS PROJECT 3 PUBLIC ADRESS AND CLOCK SYSTEM RISER T501, N.T.S. 1/2" 3/4" N SEPARATE HOMERUN TO EACH ROOM SPEAKERS -- 3/4" 1 1/4" FOR FOR VOICE DATA 3/4" e 1 1/4" 0 0 0 CCI�� 3/4" 1 1/4"_ FOR FUTURE 4 " FLOOR BOX AND OUTLET DETAIL T501, N.T.S. OUTDOOR SPEAKERS. PROVIDE A SEPARATE WP HOMERUN FOR EACH SPEAKER (IF APPLICABLE). FL TO ADMINISTRATIVE CONTROL CONSOLE -�S —_� TO REMAINING CORRIDOR SPEAKERS. CORRIDOR SPEAKERS. - - TO REMAINING CLOCKS. REFER TO CLOCK WIRING I I DETAIL TYPICAL VOICE WIRING TO IDF. REFER TO TECHNOLOGY DWGS. TYPICAL TELEPHONE 1 VOICE INSERT WITH VOICE ICON NOTE: FLOOR BOX, PATHWAY AND PLASTIC BUSHING AS NOTED ABOVE AND PER DIVISION 26 SPECIFICATIONS. PROVIDE PULL STRING IN ALL CONDUITS FOR LOW VOLTAGE CABLING BY CONTRACTOR/OWNER/AV INTEGRATOR. OTHER KNOCKOUTS/CONDUITS AS REQUIRED PER DIVISION 26 SPECIFICATIONS FOR POWER/OTHER SERVICE(S) TO THE FLOOR BOX. PROVIDE APPLICABLE MOISTURE BARRIER FOR SLAB ON GRADE BOX INSTALLATIONS. BLANK INSERT -- GENERAL -NOTES - INTERCOM/MASTER CLOCK SYSTEM 1. ALL WIRING SHALL BE PLENUM RATED. TYPICAL WIRING SHALL BE AS FOLLOWS: INTERFACE TO TELEPHONE SYSTEM - FOUR CAT 6 CABLE ADMINISTRATIVE CONTROL CONSOLE RECEPTACLE - #16 3 PAIR TWISTED SHIELDED CABLE MUTE CIRCUIT - #18/2 TWISTED PAIR. 2. ALL WIRING IN NORMALLY OCCUPIED (FINISHED) AREAS OF THE BUILDING SHALL BE INSTALLED CONCEALED FROM VIEW WITHIN THE BUILDING STRUCTURE. WIRING MAY ONLY BE INSTALLED EXPOSED TO VIEW IN MECHANICAL AND ELECTRICAL ROOMS, AND ROOMS WITHOUT CEILINGS (EXPOSED TO STRUCTURE ABOVE). PROVIDE MINIMUM 3/4" EMT CONDUIT FOR WIRING RUN WITHIN WALLS, ABOVE NON -ACCESSIBLE CEILINGS, AND WHERE EXPOSED TO VIEW. PROVIDE EMT CONDUIT SLEEVES FOR ALL WIRING PENETRATIONS THROUGH WALLS, CEILINGS, AND FLOORS. PROVIDE NYLON BUSHINGS ON ALL OPEN CONDUIT ENDS TO PREVENT CHAFFING OF WIRING. DO NOT USE THE CABLE TRAY SYSTEM FOR INTERCOM/MASTER CLOCK WIRING. ALL RACEL"JAYS A\1rrADCQUAME NEATLY INSTALLED A ITH I MCBM , AND CABLE RUNS (INSTALLED PARALLEL TO, OR AT RIGHT ANGLES TO, THE LINES OF THE BUILDING. OPEN CABLE RUNS INSTALLED ABOVE ACCESSIBLE CEILINGS SHALL BE BUNDLE TIED IN A NEAT AND ORDERLY MANNER WITH NYLON CABLE TIES. MAXIMUM DISTANCE BETWEEN CABLE TIES SHALL BE FOUR FEET. SUPPORT CABLE BUNDLES WITH APPROVED STRAP HANGERS. MAXIMUM DISTANCE BETWEEN STRAP HANGERS SHALL BE EIGHT FEET. IDENTIFY CABLE BUNDLES WITH BUNDLE TAGS AT INTERVALS NOT EXCEEDING SIXTEEN FEET. IDENTIFY INDIVIDUAL CABLES WITH NUMBERED WIRE MARKERS AT ALL ORIGINATION POINTS, JUNCTION POINTS, AND TERMINATION POINTS. 3. SPEAKER CIRCUITS ARE 25V WITH LINE MATCHING TRANSFORMERS AT THE SPEAKERS. THE CONTRACTOR SHALL INCLUDE IN THE BID FOR RE -TAPPING SPEAKERS AS DIRECTED BY THE ARCHITECT IN ORDER TO r M' AInl nATInl"A/"�T M%f n/ll lnln LEVELS. U6 I HI IV JH I IJf AC 1 Url 7 SOUIVU 4. SYSTEM PAGING ZONES SHALL BE SET UP AND PROGRAMMED AS DIRECTED BY THE OWNER. 5. PROVIDE WIRING AND CONNECTIONS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM WHETHER SHOWN ON THE DRAWINGS OR NOT. 6. THE RISER DIAGRAM IS FOR SCHEMATIC PURPOSES ONLY AND IS INTENDED TO ESTABLISH THE SYSTEM TYPE AND WIRING REQUIREMENTS. THE CONTRACTOR SHALL FURNISH, INSTALL, AND WIRE ALL DEVICES SHOWN ON THE FLOOR PLANS. PAGING CLOCK AND SOUND SYSTEMS RISER NOTES 1 16 AWG 2-COND. NON SHIELDED MAX. 30 CLOCKS PER LOOP - CONSULT SYSTEMS INTEGRATOR FOR OVERALL RUNS EXCEEDING 350' - RUN TO MDF PREFERRED - RUN TO IDF POSSIBLE - CONSULT SYSTEM INTEGRATOR FOR DETAILS. 12 AWG 2-nnNn NON SHIFT nFn MAY R SPFAKFR PFR I QnP - TAP 1,25 WATTS/25\/ O 22 AWG 2-COND. SHIELDED HOME RUN TO MDF PREFERRED, BUT WERE NECESSARY CROSS -CONNECT TO SHIELDED BACKBONE AT EACH IDF. 4O 22 AWG 4-COND. SHIELDED HOME RUN TO MDF. 22 AWG 4-COND. SHIELDED HOME RUN TO MDF 6O IF DEDICATED SPEAKER LOCATION - 22 AWG 2-COND. SHIELDED. IF PART OF A GENERAL PAC,INn 7nNF THEN I nnP WITH SPFAKFRS 1R AWG p-CnNn NnN SHIFT nFD (7 18 AWG 2-COND. NON SHIELDED HOME RUN TO MDF, LOOP HORNS ONLY WHEN ON THE SAME SIDE OF BUILDING OR WITHIN SAME ROOM. gO IF OFFICE LOCATION 22 AWG 2-COND. SHIELDED, IF HALLWAY OR PART OF PAGING ZONE - 18 AWG 2-COND. NON SHIELDED. UTP VOICE PATCH TIE CABLE: IN THE MDF, A TIE CABLE WILL BE INSTALLED TO MAKE CONNECTION BETWEEN THE TELEPHONE DISTRIBUTION CABLE AND THE PHONE PATCH PANELS. EACH 48-PORT PATCH PANEL SHALL BE CONNECTED TO A 100 PAIR 110 BLOCK WITH A 100 PAIR TELEPHONE CABLE. THE PATCH PANEL SHALL BE WIRED SO THAT 2 PAIR FROM EACH MODULAR JACK SHALL BE WIRED TO THE 110 BLOCK. CONTRACTOR TO SURVEY AND FIELD VERIFY FOR TOTAL COUNT PANELS TO BE INSTALLED IN THE IT ROOM. SPECIFICATIONS: CABINET/RACK TERMINATION JACK TYPE: 8-PIN, MODULAR, EIA/TIA 568A, CAT. 5E PANEL SIZE: STANDARD 19" EQUIPMENT RACK MOUNTING WITH 48 JACK PORTS PER PANEL. WIRE TERM.: 110 TYPE IDC TERMINATIONS, 2 PAIR PER JACK, PINS 3-6. CONTRACTOR TO TERMINATE AND PATCH PAIR FOR PAIR — STATE PROJECT NO. ACCORDING TO THE COUNTS FROM HIS SURVEY AND FIELD 132-0089 N VERIFICATION 1 PHASE 2 OF 5 aaaa aaa❑ aaaa aaaa 0 ❑❑a❑ aaaa ❑❑a❑ aaaa 0 10 n o o a aaaa 0000 ❑aaa aaaa 0 10 0 0 0 0 aaaa ❑aaa ❑aaa aaa❑ 0 0 lo 0 0 a \l aaaa aaaa ❑aaa aaaa 0 0 Yylll a a [DID aa aaaa aaaa aaa❑ 0o o 01 0 K MODULAR PATCH PANEL 110B TERMINATION BLOCKS 1 TELEPHONE TIE CABLE DETAIL rX Sot N.T.S. __ _ __-------- --- MASTER CLOCK 10:46LLLLJ O Uj 25 26 DATA/POWER =4 �a V 12 NEUTRALWHITE \—J POWER BLACK I DATA YELLOW 9 —� _6�' TYPICAL CLOCK 1 2 I 0 — 0 0 3 4 110V NEUTRALWHITE \ POWER BLACK DATA YELLWO9 3i �6 TYPICAL CLOCK 2 MASTER CLOCK SYSTEM WIRING INFORMATION — --- -- --- - T501 N.T.S. U C , a � C Vm — C TYPICAL 2 DATA INSERT 9 Moody Road =' Building D Suite 18 WITH DATA ICONS Q Enfield, CT 06082 T.860-341-1206 F.860-239-1358 0 www.gtc.us.com N tUJ \ j TYPICAL COMMUNICATIONS BRACKET. WIREMOLD/WALKER FLOOR BOX WILL 0Gp D/S;, F 0 F—__1 HAVE "#RFB-2-SSRT" P7 �7 -1 a "COMMUNICATION BRACKET" FURNISHED AND INSTALLED INTO THE Ue�; FLOOR BOX WITH COMMUNICATIONS INSERTS. w JOSEPH J NORTON m �= REG. NO. 202538R � EXPIRES 12-31-20 9� TYPICAL DUPLEX RECEPTACLE PER DIVISION 26 SPECIFICATIONS. TYPICAL DUPLEX RECEPTACLE BRACKET PER DIVISION 26 SPECIFICATIONS. BLANK INSERT moser pilon nelson architects 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE P/A, CLOCK RISER DIAGRAM AND DETAILS DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. T501 REVISIONS CONFORMED SET MARCH 22, 2019 JUNCTION BOX 4X4 2-1/8"D, MOUNTED ON I I SECURED SIDE OF DOOR AND ABOVE FINISHED \ CEILING (MUST BE ACCESSIBLE). PROCONDUIT O PS ROOM IN SPACES WITH OPEN UCEILITELECOMMUNICATIONS DJ INACCESSIBLE CEILING (TYPICAL). PS DJ JUNCTION BOX 4X4 2-1/8"D, MOUNTED ON REX REX SECURED SIDE OF DOOR AND ABOVE FINISHED CEILING (MUST BE ACCESSIBLE). PROVIDE CONDUIT TO TELECOMMUNICATIONS STATE EL EL 132-0089 NCT No. ROOM IN SPACES WITH OPEN CEILING OR DL DL ° ° INACCESSIBLE CEILING (TYPICAL). 0 0 ° ° E_MEEff EMI PHASE 2 OF 5 SECURE UNSECURE SECURE UNSECURE SECURE UNSECURE NOTE: PROVIDE ALL RACEWAY AND BACK REX REX NOTE: BOXES. Ps NOTE: NOTE: PROVIDE ALL RACEWAY AND BACK EL UNSECURE COORDINATE WITH DIVISION 8 AND UNSECURE PROVIDE ALL RACEWAY AND BACK KP a UNSECURE CONTRACTOR TO COORDINATE BOXES. OWNER BOXES. WITH FLOOR PLANS ACTUAL COORDINATE WITH DIVISION 8 AND SECURE FOR FURTHER INFORMATION SECURE COORDINATE WITH DIVISION 8 AND vEs CR SECURE DEVICES REQUIRED. WHERE NO OWNER OWNER FOR FURTHER INFORMATION "VES", "KP" AND/OR "CR" IS NOTED FOR FURTHER INFORMATION NOTE: ON A DOOR IN FLOOR PLAN CONTRACTOR TO COORDINATE WITH O INDICATES THOSE ITEMS SHALL FLOOR PLANS ACTUAL DEVICES REQUIRED. NOT BE INCLUDED FOR THAT """" "" SPECIFIC DOOR. WHERE VES, KPAND/OR CRIS NOTED PLAN VIEW PLAN VIEW O PLAN VIEW � ON A DOOR IN FLOOR PLAN INDICATES THOSE ITEMS SHALL BE INCLUDED FOR j THAT SPECIFIC DOOR. ;'■■1 ■'; TYPICAL SECURE DOUBLE DOOR WITH VIDEO AND KEYPAD(AC S-2 -- TYPICAL MONITOR DOUBLE DOOR Dc 22 TYPICAL SECURE DOUBLE DOOR t A l2A (4A O ' w JUNCTION BOX 4X4 2-1/8"D, MOUNTED ON JUNCTION BOX 4X4 2-1/8"D, MOUNTED ON v 1 SECURED SIDE OF DOOR AND ABOVE FINISHED SECURED SIDE OF DOOR AND ABOVE FINISHED JUNCTION BOX 4X4 2-1/h� CEILING (MUST BE ACCESSIBLE). CEILING (MUST BE ACCESSIBLE). DO MOUNTED ON F� PROVIDE CONDUIT TO TELECOMMUNICATIONS PROVIDE CONDUIT TO TELECOMMUNICATIONS SECURED SIDE OF DOOR AND ABOVE ROOM IN SPACES WITH OPEN CEILING OR ROOM IN SPACES WITH OPEN CEILING OR FINISHED INACCESSIBLE CEILING (TYPICAL CEILING (MUST BE ACCESSIBLE). INACCESSIBLE CEILING (TYPICAL). ) PROVIDE CONDUIT TO TELECOMMUNICATIONS TO DOOR CONTROLLER ROOM IN SPACES WITH OPEN CEILING OR PS l w INACCESSIBLE CEILING (TYPICAL . Di REX REX O EL EL EL rT -o o— CR PP PP w o O � V o CR o V C—' O SECURE UNSECURE SECURE UNSECURE SECURE UNSECURE SECURE JUNCTION BOX 4X4 2-1/8"D, MOUNTED ON UNSECURE O NOTE: SECURED SIDE OF DOOR AND ABOVE FINISHED PROVIDE ALL RACEWAY AND BACK CEILING (MUST BE ACCESSIBLE). onvirc KInTC. NOTE: PROVIDE CONDUIT TO TELECOMMUNICATIONS OUAF-0. 14U 1 L UNSECURE REX COORDINATE WITH DIVISION 8 AND UNSECURE PROVIDE ALL RACEWAY AND BACK UNSECURE 0 PROVIDE ALL RACEWAY AND BACK ? ROOM IN SPACES WITH OPEN CEILING OR EL OWNER BOXES. BOXES. IL INACCESSIBLE CEILING (TYPICAL). SECURE PS CR FOR FURTHER INFORMATION SECURE COORDINATE WITH DIVISION 8 AND SECURE COORDINATE WITH DIVISION 8 AND L11 CJ PS NOTE: OWNER OWNER �^ CONTRACTOR TO COORDINATE WITH FLOOR FOR FURTHER INFORMATION FOR FURTHER INFORMATION V 1 1 PLANS ACTUAL DEVICES REQUIRED. WHERE "VES", "KP" IS AND/OR "CR" NOTED ON A DOOR j Do REX Do PLAN VIEW IN FLOOR PLAN INDICATES THOSE ITEMS SHALL PLAN VIEW PLAN VIEW BE INCLUDED FOR THAT SPECIFIC DOOR. F TYPICAL CARD READER SINGLE DOOR (ACS-1) TYPICAL MONITOR SINGLE DOOR °�' TYPICAL MONITOR SINGLE DOOR MAG LOCK "ML" (IF APPLICABLE) I « I U 01 C 2C C2C o— Fm� PP NOTE: SLAB MOUNT JUNCTION BOX FLUSH IN CEILING OR STUB DOWN AND BRACE DETECTOR BELOW OBSTRUCTIONS THAT BLOCK THE DEVICES \ 1� VIEW. SECURE UNSECURE �--CONDUIT CONDUIT LENGTH REX SINGLE GANG J BOX INSTALL TO BE DETERMINED USING EXPANSION ANCHORS O ONDUIT UNSECURE EL PP NTO SLAB. SHOW DETAILS OF ) BY LOCAL CONDITIONS IMOUNT ON SHOP DRAWINGS. PS D I CON DUIr 0 � O ROOF HATCH — / SECURE vi 4" OCTAGONAL J-130 IN CEILING ---1 _w U IV V I E: wl �7 PROVIDE ALL RACEWAY AND BACK OCTAGON BOX LOWER EDGE OF SUSPENDED CEILING INSIDE DOORS PP BOXES. U TOP VIE PLAN VIEW c COORDINATE WITH DIVISION 8 AND OWNER o R REX FOR FURTHER INFORMATION \ UNSECURE SIDE ROOF EL PP CEILING MOUNT DETECTOR SECURE AREA DO PS DO 9 Moody Road .S DJ Building D Suite 18 Q Enfield, CT 06082 ti NOTE: SIDE VIEW TO ACP MDF rn 860-341-1206 T. CONDUIT LENGTH TO BE SUCH THAT THE BOTTOM F. 860-239-1358 OF THE J-BOX IS EVEN WITH THE BOTTOM OF THE www.gtc.us.com 0 SUSPENDED CEILING OR OBSTRUCTIONS. wwW.gtc.us.com N OUTSIDE DOORS � C0) vvPLAN VIEW PP JN�G SST INTRUSION 360 PIR CEILING MOUNT DETECTOR INTRUSION - 360 PIR CEILING MOUNT DETECTOR ROOF HATCH TYPICAL CARD READER DOUBLE DOOR SET WITH AUTOMATIC OPENER G-' t 4D a Bicsi O 5W- JOSEPH J NORTON om JUNCTION BOX 4X4 2-1/8"D, MOUNTED ON REG. No. 202538R SECURED SIDE OF DOOR AND ABOVE 6 EXPIRES 12 31 20 a FINISHED CEILING (MUST BE ACCESSIBLE). R �D •�`�G/ PROVIDE CONDUIT TO TELECOMMUNICATIONS TO ACP / ROOM IN SPACES WITH OPEN CEILING OR TO ACP INACCESSIBLE CEILING (TYPICAL). DJ RUN WIRE INTO BOX, RUN WIRE I CONCEALED IF DETECTOR CAN TO ACP / NOT MOUNT TO BOX m n c r r CABLE A I DC ■■■vvv■ O 12mm GROMMETTED HOLE FOR I WIRE PASS THROUGH SINGLE -GANG BOX FLUSH IN WALL OR CEILING MOUNT GIMBAL MOUNT BRACKET (SEE \ l 1 SCHEDULE pilon LE FOR LOCATIONS REQUIRED) i1 0 ° DETECTOR BACK PLATE nelson SINGLE -GANG BOX ° FOR FLUSH IN WALL OR MOTION DETECTOR SEE ° FOR 3architects ABOVE IN BEAM CALL FLANGES SPECIFICATIONS WETHERSFIELD, CT. 06109 ° (860) 563-6164 SINGLE -GANG PLATE ° AS REQUIRED 0 PLAN VIEW UNSECURE SIDE UNSECURE TITLE FRONT VIEW INTRUSION AND ACCESS CONTROL DRILL 9mm HOLE F DETAII.. ACCESS ITYP. OF 2) GLASS BREAK DETECTOR SEE SPECIFICATIONS DATE 11/02/2018 INTRUSION - MOTION DETECTOR WALL MOUNT INTRUSION - GLASS BREAK WALL MOUNT ,,,CARD CONTROLLED ELEVATOR MANUAL OPERATION DOOR, KEY LOCKED WITH DOOR CONTACT COPYRIGHT (c) Moser Pilon Nelson Architects L DWG. NO. E z 0 U T601 z s TO COMMAND CENTER WIRING AS PER MANUFACTURER RECOMMENDATION REVISIONS CONFORMED SET MARCH 22, 2019 WIRING FOR DOOR LOCKING DEVICE BY DOOR HARDWARE CONTRACTOR AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS INTERCOM PROXIMITY STATION CARD `•.. RFAnFR 42" A.F.F. 42" A.F.F. RECESSED MAGNETIC CONTACTS. END OF LINE RESISTOR (EOL) 33K(OHMS) U DOOR CONT, DOOR CONTACTS COMMAND CENTER DOOR FIELD INTRUSION JUCTION BOX FIRE MONITORING "DJ" ACCESS CONTROL SYSTEM HEAD END WIRING FOR ELECTRIC DOOR LACKING DEVICE BY DOOR HARDWARE CONTRACTOR AND INSTALLED PER MANUFACTURER'S 1_�_m_k_ntc�ll�wPh(rTerNrnF�nrG DOOR CONTACT,�✓� v� HARDWARE SECTION 087100 U RECESSED MAGNETIC CONTACTS. END OF LINE RESISTOR (EOL) 33K(OHMS) (TYPICAL OF 1 ) TYPICAL DOUBLE DOOR W/READER, , DOOR CONTACT, LOCK AND VIDEO INTERCOM T602 / N.T.S. RECESSED MAGNETIC --� DOOR CONTACTS. END OF LINE RESISTOR (EOL) 33K(OHMS) PROXIMITY READERf 42" A.F.F. WIRING AS PER MANUFACTURER FRO % RECOMMENDATION COMMAND CENTER DOOR / INTRUSION ACCESS JUCTION BOXCONTROL PANEL "DJ" DOOR CONTACTS WIRING FORDOOR LOCKING DEVICE BY DOOR HARDWARE CONTRACTOR AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS O DOOR LOCKING DEVICE SEE ARCH. DOOR HARDWARE SECTION 087100 2 SINGLE DOOR W/ READER, DOOR CONTACT AND LOCK T602% N.T.S. RECESSED MAGNETIC DOOR CONTACTS. END OF LINE RESISTOR (EOL) 33K(OHMS) DOOR JUCTION BOX "DJ" DOOR CONTACTS 3 SINGLE DOOR W/ DOOR CONTACT T602 N.T.S. E z U z WIRING AS PER MANUFACTURER RECOMMENDATIO N HEAD END INTRUSION CONTROL PANEL NEXT ADDRESSABLE DEVICE WIRING AS PER MANUFACTURER RECOMMENDATIO N NOTE: ALL CABLING BY INTRUSION AND ACCESS CONTROL CONTRACTOR UNLESS NOTED NOTE: ALL CABLING BY INTRUSION AND ACCESS CONTROL CONTRACTOR UNLESS NOTED RELEASE # 1 MODEL RY-PA RELEASE # 1 MODEL RY-PA "CEU" CENTRAL EXCHANGE UNIT PT DETERMINE BY THE RFLFASF MECHANISM USED I"I 1 "!111I PP I Ir�il li�l) Irr'il li�l QTY. 1 CAT6 CABLE MAX DISTANCE 980, INTERCOM DOOR STATION r� SYMBOL = it UJ 0 00 0 0 0 0 0 0 O O o 0 O O O O O ^ O O O O V V O V V O O O O O O O O O O O O O O O O 0 0 INTERCOM DOOR STATION IE-SS EXTERIOR INTERCOM EXTERIOR SYSTEM RISER N.T.S. WHERE THERE ARE SPACES WITH OPEN CEILING OR INACCESSIBLE CEILING CONTRACTOR SHALL PROVIDE CONDUIT TO TELECOMMUNICATIONS ROOM HARDWARE AND CABLING BY TELECOMMUNICATION CONTRACTOR (TYPICAL). PATCH CABLE TELECOMMUNICATION CONTRACTOR SECURITY CAMERA GENERAL NOTE: 1. PROVIDE DETAIL SHOWN WHEREVER SECURITY CAMERAS ARE SHOWN ON FLOOR PLANS SECURITY CAMERA DETAIL i SURVEILLANCE DETAILS 1 /2" = V-0" INTERCOM ERC:OM MASTER STATION AX-8M O O O o O O O O 0 O O O O 0001 O O O O O O O H O INTERCOM SMASTER N SYMBOL= IMS TO INTERFACE WITH DOOR LOCK POvv'ER SUPPLY/CONTROLLER PROVIDE NEMA RATED BOX MOUNTED TO STRUCTURE ABOVE CEILING. DATA OUTLET SHALL BE INSTALL INSIDE BOX. PROVIDE GROMMET FOR CABLE PENETRATIONS l CEILING FLOOR AX-084C LOCATED AT MDF ROOM ON SHELF OR RACK MOUNTED IN THE ENCLOSED CABINET W50 QTY. 1 CAT6 CABLE MAX DISTANCE 980' INTERCOM gMASTER N SYMBOL= IMS IN I ERCOM MAS I ER STATION AX-8M O O O o O O O O 0 0000 000 O O O O O O O O TO INTERFACE WITH DOOR LOCK PO IfV ER SUPPLY/CONTROLLER O� O o0000 00000 1 CQ� NOTE: CORE THRU EXTERIOR WALLS AS CLOSE AS POSSIBLE TO THE CAMERA LOCATION IN THE PLAN DRAWINGS TP MINIMIZE FLEXIBLE CONDUIT FEED LENGTH POWER SUPPLY + PS-2420 U L POWER SUPPLY PS-2420U L VIKING TO PHONE LINE K-1900-5 (POTS) SINGLE GANG BACKBOX RECESSED IN WALL WITH f 1 "C. CORED THRU EXTERIOR WALL AND SEALED WEATHER TIGHT FOR DATA FEED TO CAMERA. PROVIDE OUTLET COVER EXTERIOR 4"x4" JUNCTION BOX ABOVE ACCESSIBLE CEILING FOR POWER (IF APPLICABLE) & DATA FEED TO WALL MOUNTED CAMERA. SCALE: NTS TYPICAL POWER AND DATA ROUGH -IN FOR EXTERIOR CCTV CAMERAS GENERAL NOTE: ALL DRAWINGS AND DETAILS ARE DIAGRAMMATIC AND NOT TO SCALE (N.T.S.) THE INFORMATION ENCLOSED MAY NOT CONTAIN ALL DETAILS REQUIRED FOR CONSTRUCTION. APPROPRIATE MODIFICATION MAYBE REQUIRED TO ENSURE SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE INSTALLATION OF THE EQUIPMENT SYSTEMS ARE IN ACCORDANCE WITH BUILDING PROJECT SPECIFICATIONS, APPLICABLE CODES AND STANDARDS. STATE PROJECT NO. 132-0089 N PHASE 2 OF 5 U h U 0 0 z 9 Moody Road Building D Suite 18 15S Enfield, CT 06082 12 T.860-341-1206 0 F.860-239-1358 c www.gtc.us.com N '+J o CSI Go w YJOSEPH J NORTON REG. No. 202538R = EXPIRES 12-31-20 moser i pilon nelson architect 30 JORDAN LANE WETHERSFIELD, CT. 06109 (860) 563-6164 TITLE ELECTRONIC SAFETY AND SECURITY SURVEILLANCE DATE 11/02/2018 COPYRIGHT (c) Moser Pilon Nelson Architects DWG. NO. .E T602