HomeMy WebLinkAbout387 EAST MAIN STREETnnn\/I nr- A nP')rKI IN I/� I K I CONSTRUCT A 12' WIDE 40' LONG CONCRETE RAI WITH RETAINING WALLS AND GUARD R� INCLUDED ELECTRICAL RADIANT HEAT IN RAI HEATED AREA OF RAMP TO BE 12'X40'- CONSTRUCT A 12' WIDE B OPENING PROVIDE & INSTALL OVER 6' P L BAS W/ SS COUNTER TOP M( IN -FILL C DRAWING LEGEND A-1 FLOOR AND FURNITURE PLAN A-2 DEMOLITION PLAN A-3 PARTITION AND RATED NEW WALL PLAN C-1 CEILING PLAN F-1 FINISH PLAN M-1 MECHANICAL DEMO PLAN M-2 MECHANICAL PLAN M-3 MECHANICAL DETAILS P-1 PLUMBING PLAN P-2 PLUMBING DETAILS 1A/A I 1 E, DOOR LOCAL ALARM 1 HR. RATED FIRE BARRIER SEPARATING THE SHOP & OFFICE ALL DOORS IN BARRIER MUST BE CONSTRUCTED WITH A 4" HR. FIRE RATING NOTES: SAL 15'X30' 1. SHOP AND OFFICE AREA ARE SEPERATED HVUR RAI ED WALL. 2. ALL FURNITURE WILL BE PROVIDED AND BY NEMSI. ER CABINETS COUNTER W/ BY A 1 NSTALLED 3. SHOP EQUIPMENT PROVIDED AND INSTALLED BY NEMSI. EXISTING ELECTRICAL ROOM REMOVE CEILING GRID, CEILING TILES, FLOORING & COVE REMOVE CEILING GRID, TILES & SOFFIT it r Tj ♦y h =J REMOVE EXISTING CEILING GRID, — - - --- CEILING TILES, FLOORING & j COVE it - - - - III -- I�• I I I I II I I I I II FA L� REMOVE EXISTING VCT TILES AND GLUE REMOVE EXISTING REMOVE EXISTING CEILING GRID, CEILING GRID, � CEILING TILES, CEILING TILES, SOFFIT FLOORING FLOORING TILES & COVE & COVE I f -9 �1 II ... IL L. —..J U .*1 z 0 r. y r„•1 N -------- -m----.1 4 it � .II n REMOVE EXISTING CEILING GRID & TILE n SAVE FULL TILES TO BE REUSE IN FUTURE REMOVE FLOORING & COVE 1 1 1 r --- 1 L� I L**"-J L/"�J I r� I� �I REMOVE EXISTING CEILING GRID & TILE SAVE FULL TILES TO BE REUSE IN FUTURE I I II REMOVE FLOORING & COVE II SAVE CARPET TILE v wwe — I I -- - - - - - - - - - - - - -� -- -- - wR ter. ,tn.r i w w am a-r REMOVE FLOORING TILES, &COVE DEMOLITION LEGEND — EXISTING WALL — REMOVE WALL — EXISTING CEILING SOFFIT ---------- — REMOVE CEILING SOFFIT 1 0 c E RELOCATE EXISTING ELECTRICAL PANELS SEE E1 FOR DETAILS NOTES: 1. REMOVE EXISTING LIGHTING IN THE OFFICE AREA. PROVIDE TEMP. LIGHTS AS NEEDED. 2. REMOVE FLOORING AND COVE AS NOTED. 3. REMOVE WALLS AS NOTED. 4. REMOVE AND DISPOSE OF POWER RECEPTACLES. 5. REMOVE ALL DATA/PHONE OUTLETS AND WIRING. 6. PROVIDE CARPET PROTECTION IN THE EXISTING OFFICE AREA. 7. REMOVE THE EXISTING BATHROOM PARTITIONS. CONSTRUCT A 12' WIDE 40' LONG CONCRETE RAMP START AT THE SHOP FLOOR AND TERMINATING AT THE EXISTING ASPHALT PARKING LOT WITH RETAINING WALLS AND GUARD RAIL INCLUDED ELECTRICAL RADIANT HEAT IN RAMP HEATED AREA OF RAMP TO BE 12'X40'-3" SEE DETAIL CONSTRUCT A 12' WIDE OPENING PROVIDE & INSTAL OVEF CONSTRUCT A 8'X7'X6" CONCRETE REIN PAD FOR THE GEf IN -FILL SECTION A- I 12' 6" 6" RAMP DETAIL NOT TO SCALE SECTION B-1 SECTION C-1 MMn\/Inr- A nI-)CNIINIn I N I 1A/AI I E, DOOR LOCAL ALARM 1 HR. RATED FIRE BARRIER SEPARATING THE SHOP & OFFICE ALL DOORS IN BARRIER MUST BE CONSTRUCTED WITH A 4" HR. FIRE RATING )SED 15'X30' :SIGN NOTES: ALL NEW PARTITIONS BE TO BE CONSTRUCTED FROM 3 R", 25 GA., 9' TALL METAL STUDS WITH SOUND BATT AND $" GYPSUM BOARD BOTH SIDES UNLESS OTHERWISE NOTED. '. ALL 1 HR. RATED FIRE WALLS MUST BE CONSTRUCTED FROM 3 $", 20 GA. METAL STUDS WITH SOUND BATT AND $" FIRE RATED GYPSUM BOTH SIDES. WALLS MUST BE CONSTRUCTION FROM THE FLOOR TO THE METAL DECKING ABOVE. i. PROVIDE HILTI UL RATED FIRE SEALANT AT TOP, PENETRATIONS AND AT DISSIMILAR MATERIAL. CEILING GRID TO REMAIN r.EILINC; TILES NO CEILING IN SHOP , EXISTING CEILING GRID AND TILES TO REMAIN REPLACE TILES AS NEEDED NOTES: 1. PROVIDE NEW LED LIGHTING IN NEW CEILINGS. PROVIDE TWO SUPPORT WIRES FROM THE LIGHT TO THE DECK. 2. REPLACE LIGHTS IN THE CEILING WHICH WILL REMAIN WITH LED LIGHTING. PROVIDE TWO SUPPORT WIRES FROM THE LIGHT TO THE DECK, 3. NEW CEILING GRID AND TILE TO MATCH EXISTING 2'X4' CEILING GRID AND TI LE. 4. SEE MECHANICAL PLANS FOR AIR DIFFUSER LOCATIONS. 5. REMOVE AND REPLACE SPRINKLER HEADS AND INSTALL IN LOCATIONS AS SHOWN ON THE DRAWING. ALL FIRE SPRINKLER WORK MUST BE PERFORMED BY A LICENCE SPRINKLER FITTER AND MUST MEET THE LATEST LOCAL AND N FPA. EXISTING CEILING GRID AND TILES TC REPLACE TILES AS ARMSTRONG IMPERI STANDAI 51903 BLUE REMOVE E FLOOR AND SEAL EXISTING CARPET TO REMAIN WALK -OFF CARPET TYPICAL �'�"`""''"�''� � `� �' � ISOGRAD IGD 154-1 19, POLAR NIGHTS CARPET UNLESS NOTED FIRE BARRIER THAT SEPARATES THE OFFICE FROM THE SHOP �G CERAMIC FLOORING :MAIN TYPICAL PARRALLEL 20 #J6218 COLOR MULHOLLAND DRIVE 12"X24" LVT TYPICAL NOTES: 1. PROVIDE NEW 4" RUBBER WALL BASE THROUGH -OUT INCLUDING AREAS WHERE EXISTING CARPET IS TO REMAIN. ROPPE COLOR 123 CHARCOAL. 2. PROVIDE TWO COATS OF PAINT TO ALL WALLS IN THE OFFICE AREA. SHERWIN WILLIAMS #SW 6252 ICE CUBE EGGSHELL FINISH. 3. PROVIDE ONE COAT OF GYPSUM BOARD PRIMER ON WALL NEW WALLS. 4. PROVIDE TWO COATS OF PAINT TO ALL STEEL DOOR AND WINDOW FRAMES. SHERWIN WILLIAMS #SW 6252 ICE CUBE SEMI -GLOSS FINISH. 5. PROVIDE TWO COATS OF PAINT TO ALL CEILING GYPSUM SOFFITS. SHERWIN WILLIAMS #SW7007 CEILING BRIGHT WHITE FLAT FINISH. PROVIDE POWER CIRCUIT FOR ELECTRICAL RADIANT HEAT PROVIDE NEW 48 KW GENERATOR. INSTALL 0 2' FROM BUILDING AN FROM DOOR EXISTING ELECTRICAL LEGEND 9 - 120V POWER RECEPTACLE Wo]rA'kVMNTAWTA W . Moll NWAR M . i �E- 120V POWER RECEPTACLE- RGENCY POWER ) CUBICLES PROVIDE EMERGENCY POWER AND DATA TO CUBICLES PROVIDE EMERGENCY POWER AND DATA TO CUBICLES J-BOXES IN CEILING & �.IRCUITS TO EXISTING CIRCUIT PANELS IN NEW LOCATION TIDE EMERGENCY POWER DATA TO CUBICLES NOTES: 1. BSC SERVICES WILL PROVIDE ALL HOLES THROUGH EXISTING WALLS AS NEEDED. 2. REUSE EXISTING ELECTRICAL CIRCUITS WHEN POSSIBLE. 3. ALL UTILITY SHUT DOWN MUST BE COORDINATED WITH BSC SERVICES. 4. ALL ELECTRICAL WORK MUST BE PERFORMED BY A LICENCE ELECTRICIAN AND MUST MEET THE LATEST LOCAL AND NATIONAL ELECTRICAL CODE. �� °� d 5 i i I �I I I I I I I I I 20 AM P 20V 20 A® 120V 1200V 1211V] I 2 I I I I I i db 0 30 iP . P 208 V - 20 V 3 3 H. 208 V i 3 PH i i ' I I i Lr / u j CU 1 cu I I I I � 20 AMP 20 ARIP 'I 2 i 1 t L ________J I i i E RTU =EF 1 30A®T 2 )"V ID 2 ---- 3 PH I i i30 AMP T -- ----_ __ - - ------------------------------- ----- - -------------�-------------�---- ---- ---- ------------ - - - - - - - --- 208V _ I T 30 AMP -- - �1DIIC fi000 T i 208 V AC °h 2 3 PH 3 2 I RTU E I I j- 3 I SAW Rlli --------------------------- 1z Hp I I 2 20 AMP 120V i I I ---- ----- EF I 3 I I I I I I I I 3 P PLASMA TABLE I i 20 AMP EF EX: 4500 CFM 5 Hp 120V 46"x46" I i 1 i I I I I I EI I �TU UT I I I I Rlh1 = `- I 4 I ul I I I I I I I I I I I I I i i i F7 I L_J ------------------- '------------ --- - ---- ---- - �- -- I I I I I I I I --------------------------- -------------- I \V \V \/ \V \/ \V \/ \V �Z� \V \V \V \V \V \V \V \V \V \V \V \V \/ \V \V \V V 0 x18 I E RTU NO CT I I I i I 18 —------------ I I '�/�/ �/_I�/u�/u�/�/�/\/�/� I LIGHTING I uUuuu�uuuuU �/ �/ �/ �/ �/ �/ �/ �/ RELAY PANEL I ��\V \V \V \V \V \V \/1�������� -------------- -- ------------------------------------------------- - - - v — - u-- - ------_----- ---- -- - - --- --- - - u �/ - -�- ------ --- ---- --------- I IE I 160 C� w I D 1 1 I 3-WAY " 8 o i I I I I 160 CFM 8 II #8o I T CT I I ' I ' I SHOP AHUs III "� I - Y 3-WAY 20"x20x I 600 CFM 250 CFM "` I i 12"0 IEl 4 ETR 24"4" ,I 18 I I O-/ w --------------------------------------- ---- 18" _i_ 1 T ETR RTU I 3-WAY 160 CFM f I ------------- ------------ ------ -- - EMME --- - - - - - - - - - ---- ----- --- - - - --- ----------� -� - ----------- - - -- ---------- ---------------------- - --- - -I-- - 3 - -- -- - - - - - - - - -------T---- - - -i - ;------------------ -- ------------ I 0120V 2-WAY I - AY 150 CFM O I 12"� 36-WAY 16"0 275CFMI _ ' 3-WA I I 3 W ----------- - - - ----------- ID 1150 fETR 18"x12" g"� i---- HM ESYSTEM ii I �--------------- - ----- AY I s I .� I i I 450 CFM PNEUMA DAMPER TYP T I " T II ( ) I -- --7 10 o 3-WAY s I O 160 CFM 3-WAY i i T w T -- _ -- --- --- ---- -- - - I T -- - - - �160-CFM------------------ - I- - - - E ETR 12"� 3-WAY 8"� . r w " 3-WAY - - - - - - 3 2-WAY - - - T1111 8"� M 75 -,"- ..,.. w � I - 1 = 3-WAY 3-WAY 150 CFMLAJ I 150 CFM T I 4 I I 175 CFM 175 CFM w I -- i 300 I 8 i � ----- � TRANSFER DUCT 800 I T F-�1 -�I F-� I ; i I t SEE DETAIL ) } i E 24"x14" ETR 2"0 I i Imo- ----- - T -- I ETR 12" i I 3-WAY Y. - I I �------------------I---- I I r —I 3-WAY 400 CFI -- - ----- ----� 1 _ T -- - -- T I � 160 CFM TRANSFER �_-- -- _ _ _ 6T- - I I I __ _-- I 3 WAY - { -- ----------- I SE DETAi (TYP) i T I II I 2 WAY - --- _-- -_ _-_ I " =50 CFM '�:1 3- Y MMES�STEJ� RTU AY S ART SENIOR i ETR 14"x14" ETR "I J 3-WAY CT 9 I 150 CFM O i 8 16 i s OOWCFM I 4-WAY 3 I "" 3-WAY I I I I " I 600 CFM ETR 14 x14 300 C I�� " " 150 CFM I " TR 12 0 ETR 24 x14 i i I 8 o ETR 1211 0 { 8007 8"� I r� I I I I 8 3-WAY----�-- i3-WAY3- I I I E RTU I T I I r s AC AC I I 150 CFluu�'- 3-WRY`/Ilk T 160 CFM 160 FM M 10 CONNECT DIFFU ER " 0 C I I I I 12 ` ------ ------ f 4 5 , TO EXISTING DUCTWOR ! (TYP.) I I I -- ---------- ------ ---� I 3-WAY,'`0-\ -a I i .w M i I TRANSFER DUCT I 350 C I 150 C Y I I I i SEE DETAIL (TYP) 3-WAY PC SW 12"0 i I Q I I --� I - I 350 CFM " .,.. --- -- -I -- - - -------------------------------------------- � -- -------------- 4 I------- ----- I10,11 ............ -L -------- r 8"o � I T I � 3-WAY -------j<i 3-Wq 47 1175 CFM I MASTER T-�-'� 135 CFM - EMME I—IT-^7_wev l I — -•-3-WAY 1 71 --- 3-WAY O OFT r w T f I 10"0 I ...- 3-WAY 3-WAY 4-WAY 300 CFM 400 CFM 1250 CFM I .» I I 275 CFM 275 CFM zi5 cr I tmmtl 4-WAY j i 120V� I 200 CFM J 10"o I _fI i 2-WAY 200 CFM I I EMM I I - � T T T 3-WAY 120 » SW 3-WAY T T iv _�NAX__ 0 w E1R RTU 12"0 T 1 130 C S I ; -» 1 » " " 600 CFM I I 4-WAY 0 _ I _ 100 CFM 13 230WC Y t 200�CFM "� " w 130WC Y 3-�VAY 130 AY 16 0 14 0 112 i w 2-WAY 200 CFM pT I 8 " 130iCFM CFM T !---------- --- r /� ETR 12 0 $"� — I ------------ly-t-1-- J-------- -- -------------- —---r------�-�-- -- ---- ------------ ------ 4-WAY 6 0 -WAY 4f WAY 50 CFM f0 CFM 10a CFM I r-------------- ----- , I CONNECT NEW DIFFUSER i 20VIT TO EXISTING DUCTWORK (TYP.) I I ETR RTU IOCQE WAY L M 12 I 100 CFM 4-WAY P 3-WAY I -�- �„ O ETR 12"o l 100 C j a 300 CFM i i I ------------ T------- - -2-Y---- J I I WA-- I �-- 225 CFM i 10"0 ETR 10"0 I I �---,-----r---� T I _... �-� I I I 3- AY T � i � ; 0 FM I T� I r- -- - w4-WAY -- ----- I -- --- - O-- ----- 10 .r i I- - CFM — —I- — - — 8 4-WAY i -� ------ j--- s 125 CFM -- li-� 4-WAY T 1 125 CFM 1 3-WAY — 300 CFMi I O L I I I I � I I T T i T T I I I---r }--------------- }-----------� ---}a— —------- } 4-W IY 700 s 4-WAY 2-WAY 4-WAY 300 CFM 300 CFM 300 CFN CONNECT NEW DIFFUSER TO EXISTING DUCTWORK (TYP.) I I i -------------------------- a) --------- ---------r _ 3 M s 3-WAY ♦y ETR 12"0 " 3 175 CFM ETR 12 -- 450 CFM----- ------ ---- ----- ------ ----i ---------- ------------ - - - - - - - - - - - - - - - - - I----- -- 2-WAY I I ETR 12 "0 i ETR 12"0 ff » 3-WAY 200 CFM ' i `E1 12"0 i I 8 130 CFM T I I I; I T I T= 0 400 CFM------------ ----- 4�WiY \ s 25�0 CFM w I I I I 3-WAY 3-WAY T 00 CFM 500 CFM ADD RAWAL VALVE RTU-14 I I 4 I 100 CFM T 4- )1Y 50 (I =1.�� E AUST FAN 30 MINUTE TIMER 9"LINED w 4-WAY 12"0 400 CFM RETURN PROVIDE 2-WAY Z-WAY}--- ES TYP 175 CFM j 175 CFM i 4-WAY NEW GRI (TYP) r-- 400 CFM 8"� s 12"0 �E' 12"0 - - - - - - - - - - - - - - - -1 -- ---- - - - - - - - - ----- ------ - --- I - $� 02S 0 - -- I1.------------ ---- - - -- - - --- -- --------------- ETR RTU - - �- - -(: - 1O"o I i ETR 12"0 TR 28"x20" 14 i i j TAD- ---------------------------------------- I I - 1-------,-- --�-- MME ------,------------------7---�� I 120V I ~ I /-ETR 12"0 i ETR 12"0 �ETR 12"0 i ETR 28"x20" ETR 12"0 i � it I i I I I i EMME SYSTEM i_�ETR 12"0 I �___ PNEUMATIC DAMPER (TV I I ----- r �� i ETR 12"0:7 T 3-WAY 350 CFM 3-WAY 350 CFM I I I i I I I T I 6O O r I .gg 3-WAY 3-WAY :350 CFM 350 CFM' 350WACj>s 50 WAY FM I I 3-WA' 350 C1 �I s 500 ---------- I I I i PLAN NORTH NOTES 0 EXISTING TO REMAIN EF & T-STAT SERVING EXISTING DATA CLOSET O REPLACE EXISTING T-STAT WITH DELTA T-STAT, LOCATE IN WEB OF COLUMN 3 ii; LINE EF WITH t°�AI ! CAP AND BDi;.. LOCATE GRILLE ABOVE MICROWAVE O INTERLOCK WITH TOILET EF WITH LOCAL RTU SO EF OPERATES DURING SCHEDULED/ OVERRIDEN RTU OPERATION FLOOR PLAN 1 /811 1'-011 WALL TRANSFER rNI [^*r IIIITI I TRANSFER DUCT DETAIL (TYP) NTS UP TO ROOF PANEL CHOP SAW EXHUAST DETAIL NTS PLASMA TABLE EXHUAST DETAIL(PLAN VIEW) NTS III I Vu unllll LI\ PLASMA TABLE EXHUAST DETAIL(SECTION VIEW) NTS EMME SYSTEM T THERMOSTAT LIGHT SWITCH 3" CODE MINIMUM I_11; THERMOSTAT MOUNTING DETAIL NTS HVAC DUCT INSULATION CYSTMA il�\JULlA1Tl v1,\ TYPE NOMINAL MINIMUM III\STALLED INSTALLED DENSITY THICKNESS ASSEMBLY INDOOR DUCT/PLENUM EXPOSED SA AND RA: LOCATED IN MINERAL FIBER BOARD MECHANICAL ROOMS, OTHER ON -OCCUPIED SPACES, NON -At NTH REFLECTIVE VAPOR 3 LB/FT' 2" R-3.5 CONDITIONED SPACES, PASSING BARRIER THROUGH AIR CONDITIONED qPAQPq DUCT LINING DUCTS INSTALLED INDOORS, SA AND RA DUCTWORK WHERE NDICATED ON THE DRAWINGS ANE FLEXIBLE FIBER GLASS 3/4 LB/FT3 1" R-4.2 IN THE SPECIFICATION 5 FT NITH REINFORCED COATIN DOWNSTREAM OF SUPPLY FANS. RETURN FANS AND 5Fr OWNSTREAM OF TERMINAL BOXE WHETHER INDICATED OR NOT. EXHAUST AIR SYSTEMS DRYER, LABORATORY FUME HOOD FIRE -RATED BLANKET OR THICKNESS KILN AND ALL OTHER EXHAUST BOARD (REFER _ REQUIRED _ SYSTEMS WHERE FIRE, SMOKE TO NOTE #5) OR 2-HR FIREJ AND FIRE/SMOKE DAMPERS ARE RATING NOT PERMITTED TO BE INSTALLED WITIAIN THE DUCTWORK 1. FOR INSULATED OR LINED OUTDOOR DUCTWORK PROVIDE A PRE -MANUFACTURED SELF ADHERING PRODUCT WITH AN UV.RESISTANT, FACING. WATER VAPOR TRANSMISSION OF THE INSTALLED PRODUCT SHALL BE .020 PERMS OR LESS. PRODUCT SHALL BE SUITABLE FOR CONTINUOUS USE IN LOW TEMPERATURES OF -10117 MANUFACTURERS SHALL BE SIMILAR TO VENTURE CLAD. 2. INSULATION TYPES INDICATED IN THE SCHEDULE SHALL USED UNLESS OTHERWISE INDICATED ON THE PLANS OR SPECS 3. CLOSED CELL, FIBER FREE, ANTI -MICROBIAL COATED, LOW VOC CERTIFIED, MOISTURE AND MOLD RESISTANT DUCT LINING SHALL BE PROVIDED IN DUCTWORK AND EQUIPMENT WITHIN HOSPITAL AND HEALTHCARE FACILITIES AND ROOMS CLASSIFIED AS MOIST OR WET ENVIRONMENTS WHERE THIS SCHEDULE, DRAWINGS AND SPECIFICATION INDICATE DUCT LINING. OA = OUTDOOR AIR SA = SUPPLY AIR RA = RETURN AIR EA = EXHAUST AIR HVAC DUCT MATERIAL APPLICATION SUPPLY RETURN EXHAUST TYPICAL (UNLESS OTHERWISE SPECIFIED) G90 GALVANIZED STEEL G90 GALVANIZED STEEL G90 GALVANIZED STEEL OUTDOOR AIR INTAKE PLENUM G90 GALVANIZED STEEL OUTDOOR AIR G90 GALVANIZED STEEL ;I J EXPOSED AND CONCEALED EXHAUST G90 GALVANIZED DUCTWORK AND PLENUMS SERVING G90 GALVANIZED STEEL STEEL G90 GALVANIZED STEEL TOILET ROOMS EXPOSED DUCTWORK LOCATED IN AND SERVING CONDITIONED SPACES OTHER THAN DUCTWORK G90 GALVANIZED STEEL G90 GALVANIZED G90 GALVANIZED STEEL LOCATED IN SPACES REQUIRED STEEL TO BE ALUMINUM OR TO BE FIELD PAINTED. 1. DUCT CONSTRUCTION SHALL MEET SMACNA METAL & FLEXIBLE 2005 3RD EDITION STANDARDS ROOF TOP UNIT SCHEDULE SYMBOL MFG MODEL NO. NOMINAL SIZE (TONS) COOLING COIL DATA ELECTRICAL HEATING TOTAL MBH NET SENS. MBH SUPPLY AIR SUPPLY FAN FLOW CFM MIN. O.A. (CFM) MAX E.S.P. (IN. WC.) EAT ('F) (DB/WB) LAT (�_) DB/WB MOTOR SIZE (HP) RPM MCA MOCP VOLT/� HEATING INPUT (MBH) HEATING OUTPUT (MBH) EFFICIENCY (%) EAT DB ('F) LAT DB ('F) FUEL MIN. INLET GAS PRESSURE WEIGHT (POUNDS) COMMENTS RTU-1 CARRIER 48HJF017 15 1 180 160 7,500 4,500 1.4 80/67 59/56 5 1163 43 50 460/30 360 292 81% 60 89 NO 3.3" 1800 RTU-2 CARRIER 48HJF017 15 180 160 7,500 4,500 1.4 80/67 59/56 5 1163 43 50 460/30 360 292 81% 60 89 NO 3.3" 1800 RTU-3 CARRIER 48HJF017 15 180 160 7,500 4,500 1.4 80/67 59/56 5 1163 43 50 460/30 360 292 81% 60 89 NO 3.3" 1800 RTU-4 CARRIER 48HJF017 15 180 160 a 7,500 4,500 1.4 80/67 59/56 5 1163 43 50 460/30 360 292 81% 60 89 NO 3.3" 1800 RTU-5 CARRIER 48HJF017 15 180 160 7,500 4,500 1.4 80/67 59/56 5 1163 43 50 460/30 360 292 81% 60 89 NO 3.3" 1800 " q8@8 1 RTU-7 CARRIER 48HJE014 12.5 139 125 4,300 2,580 1.0 80/67 59/56 4.5 990 29.1 35 460/30 200 160 82% 60 89 NO 3.5" 1050 -8 __,'WRIER 48 17 0 160 7,5 4IMA4 80/ 6 63 43 5 46 60 92 1% 3 " RTU-9 TRANE YHC092F4RZA 7.5 81 64 2,600 1,560 1.2 78/63 56/53 2.75 1240 19.9 25 460/30 200 160 80% 56 113 NG 4.5" 1290 2 RTU- RIER F01 2 , 0 1.0 /5 90 2 . 31� 20 16 80 0 0 9 NG 35 RTU-12 CARRIER 48HJE008 7.5 90 r47 72 3,000 1,800 1.0 80/67 59/56 4 890 21.9 25 460/30 120 98.4 82% 60 89 NG 3.5" 870 RTU-13 CARRIER 48HJF005 4 40 1,450 1,160 1.0 80/67 59/56 4 910 11.9 15 460/3� 82 66 81% 60 89 NG 3.5" 540 RTU-14 CARRIER 48HJF017 15 180 160 7,500 4,500 1.4 80/67 59/56 5 1163 43 50 460/30 360 292 81% 60 89 NO 3.3' 1800 RTU-15 CARRIER 48HJE004 3 36 30 1,200 720 1.0 80/67 59/56 4 825 9 15 460/30 50 41 82% 60 89 NO 3.5" 530 RTU-16 CARRIER 48HJE005 4 47 40 1,450 1,160 1.0 80/67 59/56 4 910 11.9 15 460/30 82 66 81% 60 89 NO 3.5" 540 RTU-17 CARRIER 48HJE006 5 61 50 1,750 1,050 1.0 80/67 59/56 4.5 1165 14.7 20 460/30 82 66 81% 60 89 NO 3.5" 560 RTU-18 CARRIER 48HJE007 6 74 60 2,100 1,260 1.0 80/67 59/56 4 1210 15 15 460/30 82 66 81% 60 89 NO 3.5" 615 1) TO BE ABANDONED 2) NEW UNIT TO REPLACE EXISTING UNIT SPU I SYSTEM AIR COND119101'N'ER SCHEDULE SYMBOL MFG MODEL NO. LOCATION SYSTEMS SERVED AIR FLOW (CFM) SEER TOTAL CAP (MBH) SENS CAP (MBH) COOLING AIR TEMP (7) COOLING INPUT POWER (KW) ELECTRICAL DATA WEIGHT (LBS) COMMENTS MCA VOLTS PHASE AC-1 MITSUBISHI MSZ-FH09NA SHOP OFFICE 1 SHOP OFFICE 1 300 30.5 9.0 80DB/67WB 0.56 1 208V/230V 10 37.5 CU-1 MITSUBISHI MUZ-FH09NA CURB ON GRADE SHOP OFFICE 1 1150 - - 80DB/67WB - 12 208V/230V 10 105.8 AC-2 MITSUBISHI MSZ-FH06NA SHOP OFFICE 2 SHOP OFFICE 2 80DB/67WB 1.64 1 208V/230V 10 37.5 CU-2 MITSUBISHI MUZ-FH06NA CURB ON GRADE SHOP OFFICE 2 - - 80DB/67WB - 12 208V/230V 10 105.8 AC-3 MITSUBISHI MSZ-FH06NA SHOP OFFICE 3 SHOP OFFICE 3 80DB/67WB 1.64 1 208V/230V 10 37.5 CU-3 MITSUBISHI MUZ-FH06NA CURB ON GRADE SHOP OFFICE 3 - - 80D8/67WB - 12 208V/230V 10 105.8 AC-4 MITSUBISHI PKA-A18HA7 SEVER ROOM SEVER ROOM 80DB/67WB 1.19 1 208V/230V 10 22 CU-4 MITSUBISHI PUY-A18NKA17 ON ROOF SEVER ROOM - - 80DB/67WB - 13 208V/230V 10 82 AC-5 MITSUBISHI PKA-A18HA7 SEVER ROOM SEVER ROOM 80DB/67WB 1.19 1 208V/230V 10 22 CU-5 MITSUBISHI PUY-A18NKA17 ON ROOF SEVER ROOM t 80D8/67WB - 13 208V/230V 10 82 EXHAUST FAN SCHEDULE SYMBOL MFG MODEL NO. CFM SP VOLTAGE SERVING AREA LOCATION COMMENTS EF-1 GREENHECK CUBE-360XP 4500 2.50" 46OV/6OHz/30 PLASMA TABLE SHOP AREA EF-2 GREENHECK CUBE-180-30 4000 1.50" 46OV/6OHz/30 WELDING HOOD SHOP AREA EF-3 GREENHECK CUBE-240XP 2000 2.00" 46OV/6OHz/30 CHOP SAW SHOP AREA EF-4 FANTECH FG 6XL 300 0.5" 120V/6OHz/10 KITCHEN KITCHEN Part 1 - GENERAL 1.1 Scope A. Complete HVAC systems will be provided whose intent is shown on the drawings and specified herein. 1.2 Permits, Laws, Ordinances, Codes and Standards A. All work shall be designed and installed in accordance with The State of Connecticut Building Code, Connecticut State Fire Code and other applicable laws, rules and regulations of OSHA and NFPA. B. Equipment, materials and components shall bear the UL Label where required. 1.3 Work by others A. HVAC contractor to furnish starters and disconnect switches for equipment where not furnished as an integral part of mechanical equipment for installation by the Electrical Contractor. B. The Plumbing Contractor shall provide natural gas piping and domestic water to all HVAC equipment. C. The General Contractor shall provide all excavation, backffll, cutting, patching, concrete pads, flashing, waterproofing, opening reinforcement, steel dunnage, service platforms, and exterior louvers. 1.4 Workmanship and Guarantee A. All equipment and materials shall be new and selected to provide a proper installation. B. The work, systems and equipment provided under this contract is guaranteed to be free from material and workmanship defects for one year from the earlier of the date of substantial completion or the date of their beneficial use. Part 2 - MATERIALS & INSTALLATION 2.1 Ductwork A. Duct Construction 1) All supply, return, and exhaust ductwork shall be constructed per SMACNA galvanized low pressure duct standards at 2" W.G. pressure Rating. B. Fire Dampers 1) Ducts and openings penetrating two hour rated partitions and floors shall have fire dampers with access provisions. Fire dampers shall be installed in accordance with the manufacturer's recommendations. 2) Perimeter clearance openings at fire wall penetrations shall be thoroughly fire stopped using "Thermoffber" saffng or approved equal. 3) Access doors in ducts shall be a minimum of 12" x 12" or 2" less than duct width by 12" long, whichever is larger. Architectural access doors within non -accessible ceilings or partitions shall be provided by the general contractor. 4) Fire dampers shall bear the label of an approved testing agency and shall be classified and identified in accordance with UL 555. 2.2 Seismic A. Seismic restraints shall be provided for all ductwork and piping as required by the International Building Code. 2.3 Insulation A. Ductwork: 1) All unlined supply ductwork, unlined return ductwork, and outside air intake ductwork (including plenums) and shall be insulated with 1 Yz fiberglass wrap with foil faced vapor barrier. Seal all joints with matching vapor barrier tape. 2) Supply and return air ductwork shall be lined with 1" or 2" acoustical lining as shown on the drawings. 3) Existing fiberglass ductwork to remain unless otherwise noted Part 3 - INSTALLATION 3.1 Piping Supports A. Piping above the floor shall be supported by manufactured supports similar to "Unlstrut". B. Piping in ceilings shall be supported from the building structure on approved clevis type hangers. C. Piping must be supported so that no stress is transferred to equipment connections and constrained to prevent movement during starting and/or surging conditions. D. Air vents and drain valves shall be provided at all high and low points respectively. E. All piping to be blown clean or flushed then leak tested under system operating pressures. 3.2Installation A. Ductwork and piping shall be installed close and parallel or perpendicular to the structural members. B. Unless otherwise provided for on these drawings, equipment shall be installed so as to be accessible for operation, maintenance, repair and replacement. 1) Equipment and materials shall be installed in accordance with their manufacturer's recommendations. 2) Coordinate with all other trades to ensure appropriate access is maintained by all trades to allow for unhindered access to equipment and access doors. 3) Architectural access doors shall be provided as required by the General Contractor. 3.31nstallation of Hangers and Supports A. Do not hang piping or conduit from ductwork or piping. B. Hangers shall not be fastened by means of vertical expansion bolts. 3.4 System Balancing A. Provide a certified balance report demonstrating the systems are performing as intended. 3.5 Sequences of Operation A. Toilet Exhaust Fans 1) Each toilet exhaust fan shall operate when the associated RTU is operating in occupied mood as noted on M-2 A. Exhaust Fan Louvers 1) Exhaust fan louvers shall be 4" Deep with flange and a drainable blade. 2) The louver shall be constructed of anodized aluminum. Color by Architect. 3) Greenheck,or eauivalent, shall be used. SUBMITTED FOR PERMIT 1 6/15/18 1 1 REV I DESCRIPTION I DATE I BY �GOR Services England Mechanical ENGINEERS & CONTRACTORS 166 TUNNEL ROAD, VERNON, CONNECTICUT 06066 tel. 860.871.1111 fax. 860.871.9154 website: www.nemsi.com 55 GERBER BUILDING SOUTH WINDSOR, CONNECTICUT MECHANICAL SCHEDULES, SPEC, AND DETAILS1 DRAWN BY: FSI CHECKED BY' MEM DRAWING NO . I SCAM: 1/8 "=1'- o„ DATE: 6-15-18 -3 PROJECT NO. MP 18884 SHEET 3 OF 3 6 5 41 3 2 1 I ' I i i i I I I i i i I -- '---------- CA EE (E)GAS ME I I I AC I I I I I I I Cu 2"0 I I I 1 I I I I I I I 1 I I ;---------------- I AC "CONDENSATE I 2 1 I i,l 1 I� I I I I Cu I i i I I 2 1 I I I I I 1 I I I CONDENSATE I I I I I II 137 ------------------ - - - - - - - - - - I I I I I I i AC I i I I --------------------- 3 I I I I I 3 1 1 I I I I I I I I I I I I i I 1 I ' I I I I I I i j I I � I I ' 1 I I )CCONDENSATE - I I I I I I I i i I I I I ' I I I I I i I I i i I I i I I I I I � I 4---------------------------------------------—----------�------ _-_ — _-_ — _- _— _-_ — _-_ — _-_ — _-_—---------------------------------------------------------------------- ------ t--------------------------------------- — --------- —£-------- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I HB-1 ------------------------ I I I I I I I I 1 ' I I I I I ----------------------------------------- j P-� -- --- - ------ --------------------------------------------------------- -- - ------------------ ------- - --- --- ------ ------------------------- ---------- p VCHILLED WATER i I I CONNECTION TO i I I COFFEE MACHINE ❑ i !SK-2 I I � I I 1)rVENT I % 1NrSANITATION I I I IN WALL i --------- ---------- ------ ...............I I I ------------------------------------- I I I I I I i I I ,f �, ill f �, fl, I _ _-_-_-_-_- -- --- - - --------------- — — — ------------------I------ ------------------------------ ----CONNECT TOEXISTiN- i --i-------------------� - - - - - — - - - - -------------------------------- --------------i------------------ I I I I I I � 2"0 I c 0 ----------- I I I I I I I I I r 1 1 I , --- ------------------------------------------------------ ----- -------------------------- ---------------------------------------------I----------------- -- - - -- --- ---- ------ --OE I I I I I I I P I I I I I I I I I 1 I � I I IN CEILIN I I I a I I I I I 1 I I I I I � I � I AC, I I I I I 5, , I I I I I -- ------------------------- ------------------- ----------- - --------------- - - -- -------------------------------- -- --- ---------- F " - --- - " ---------------------------------------------- ---- -- ------------------ )i CONDENSATE i C NDEN SATE i I I I I I I I I I I ' I I I I I I I 2"0 I I I I "CONDENSATE GENERATOR IIIIIII III1IIIIIIII I IIIIIIIIIIiIII 0 0 c " SK-1 3ICE MACHINE 0 OUNTER COLD WATE ONNEC110N ----------------------------o 0 o R--- - ----- --- G—- - - - - - - - --------------------- - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — -- —------------- — - — - — - — - — - — - — ------------— ------------------C'wAE TAILPIECE ON L) DISCHARGE DENSATE ONNECT SK-1 SAN RY WASTE VENT &DOMES TIC SK-3 INTO JANITOR K WATER TO SERVICES ADJACENT TOILET ROOM WWATER AND VENT I I I j I I I G PROVIDE Y" COLD ER I I I TO COFFEE MACHINE LAI I I I I I I I I I I I I I ' I � I I I I I I ----------- ------- ------------ ------------- --- - ----------------- - ----- - ---------I----- -------------------------------------------- --------------- ---------------------------------- I------------ --------------------------------------- ------ - H -- ---- — I---- -- I 1 I D 0 i I i I 1 1 I — PLAN NORTH �j L) ui L' I y I 1 ;1 ;I I ;j I I I ILI I, I I I --------`-- ------ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -—- , I I --------- I I I I I I I I ' I I I I I I I I FLOOR PLAN 1 /8" = V-0" INSULATION SCHEDULE SYSTEM PIPE SIZE PIPE INSULATION TYPE PIPE INSULA11ON THICKNESS FITTING, VALVES, FLANGES — INSULATION TYPE REMARKS DOMESTIC COLD WATER ALL MINERAL FIBER, ASJ, SSL 1" FIBER GLASS INSERT, PVC JACKET TYPE 1 DOMESTIC HOT WATER ALL MINERAL FIBER, ASJ, SSL 1" FIBER GLASS INSERT, PVC JACKET TYPE 1 1. FIBERGLASS INSULATION: THERMAL CONDUCTIVITY .22 TO .28 BTU x IN./H x FT x *F W/ 1007 MEAN TEMP. THICKNESS BASED ON ASHRAE 90.1, 2007, TABLE 6.8.3 PLUMBING FIXTURE SCHEDULE FIXTUREI TAG FIXTURE I TYPE FIXTURE LOCATION FIXTURE MANUFACTURER MODEL„ MODEL NO. MATERIAL DESCRIPTION MINIMUM BRANCH SIZES REMARKS WASTE/ SANITARY VENT 1 1/2" COLD WATER 3/4" HOT WATER 3/4" SK-1 SINK KITCHEN ELKAY LUSTERTONE, ELUH2317PD STAINLESS STEEL 25 %"X 19 �/"X 8"DEEP BASIN DRAIN & STRAINER, COUNTER MOUNTED. FAUCET. ELKAY LK6000, COUNTER MOUNTED. 1 1/2" SK-2 SINK SHOP BREAKROOM ELKAY LUSTERTONE, ELUH211555PD STAINLESS STEEL 23 WX 18 34"X 5 W DEEP BASIN DRAIN & STRAINER, COUNTER MOUNTED. FAUCET: ELKAY LK6000, COUNTER MOUNTED. 1 1/2" 1 1/2" 3/4" 3/4" SK-3 SINK WELLNESS ELKAY LUSTERTONE, ELIJHAD131655PD STAINLESS STEEL 16"X 18 Y2" X 5 3/a°' DEEP BASIN DRAIN & STRAINER, COUNTER MOUNTED. FAUCET. ELKAY LK7921 SSS, COUNTER MOUNTED. 1 1/2" 1 1/2" 3/4" 3/4" PLUMBING NOTES AND 1. FURNISH AND INSTALL A COMPLETE SANITARY SYSTEM TO 5-0- OUTSIDE THE BUILDING AS SHOWN ON THE DRAWINGS. 2. FURNISH AND INSTALL COMPLETE NATURAL GAS PIPING SYSTEM FROM THE REGULATOR MAINS, RISERS, BRANCHES DRIPS, SHUTOFFS AND OTHER REQUIRED PARTS. CONNECT TO EQUIPMENT AND APPLIANCES AS INDICATED OR SPECIFIED AS REQUIRED FOR THEIR OPERATION. SYSTEMS SHALL BE IN ACCORDANCE WITH AGA/NFPA BULLETIN NO. 54, AND THE LOCAL FIRE MARSHAL'S REQUIREMENTS. 3. FURNISH AND INSTALL COMPLETE HOT AND COLD WATER SYSTEMS TO ALL FIXTURES AND SPECIAL EQUIPMENT AS SHOWN ON THE DRAWINGS AND AS REQUIRED FOR A COMPLETE SYSTEM. 4. ALL EXCAVATION AND BACKFILL SHALL BE PROVIDED BY OTHERS. 5. THE PLUMBING SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH STATE OF CONNECTICUTBUILDING CODE, INTERNATIONAL PLUMBING CODE AS AMENDED AND ADOPTED BY THE STATE OF CONNECTICUT, THE HEALTH DEPARTMENT AND THE REQUIREMENTS OF THE LOCAL BUILDING DEPARMENT. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS, FIXTURES, EQUIPMENT AND LABOR TO COMPLETE THE PLUMBING SYSTEM AS SHOWN ON THE PLANS AND SPECIFICATIONS HEREIN. 6. THE PLUMBING CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS REQUIRED BY LAW AND THE LOCAL INSPECTION AUTHORITIES TO PERFORM THE PLUMBING WORK SPECIFIED HEREIN. 7. ALL ACCESS PANELS FOR CLEANOUTS, VALVES, WATER HAMMER ARRESTORS, ETC SHALL BE FURNISHED AND INSTALLED BY OTHERS. 8. THE DOMESTIC WATER SYSTEM SHALL BE DISINFECTED IN ACCORDANCE WITH SEC11ON 610 OF THE 2013 INTERNATIONAL PLUMBING CODE. 9. PIPE PENETRATIONS THROUGH RATED FLOOR/CEILING AND WALL ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED THROUGH— PENETRA11ON FIRESTOP SYSTEM INSTALLED AND TESTED IN ACCORDANCE WITH ASTM E814. SPECIFICATIONS a. INSTALL HANGERS AND SUPPORTS COMPLETE WITH NECESSARY INSERTS, BOLTS, NUTS WASHERS AND OTHER REQUIRED ACCESSORIES. b. ALL HANGER AND SUPPORT MODEL NUMBERS SPECIFIED ARE BASED ON GRINNEL OR ACCEPTABLE EQUAL. SUPPORTS SHALL COMFORM TO MSS—SP-69 AND ANSI B31.9. WIRE AND STRAP HANGERES ARE NOT ACCEPTABLE. c. HANGARS FOR PIPE SIZES 2" AND SMALLER SHALL BE LIGHT DUTY, CLEVIS—TYPE HANGERS #65. HANGERS FOR DOMESTIC WATER IN DIRECT CONTACT WITH PIPE, 2" AND SMALLER WITH USE CT-69 COPPER BAND HANGERS OR CT-65 COPPER PLATED CLEVIS HANGERS. d. INSULATED HOT & COLD WATER PIPING SHALL BE INSTALLED WITH LINE SIZE PIPE HANGERS. INSULATED AROUND HANGERS. e. VERTICAL RISERS SHALL BE SUPPORTED WITH RISER CLAMPS, FOR PIPE 2-1/2" AND SMALLER, USE FIGURE NO. 261. 14. SEISMIC RESTRAINTS SHALL BE PROVIDED ON THE GAS PIPING IS ACCORDANCE WITH THE STATE OF CONNEC11CUT BUILDING CODE. 15. PIPING MATERIAL: a. PIPING MATERIAL SHALL BE IN ACCORDANCE WITH ATTACHED PIPING SCHEDULE. b. TRAP PRIMER PIPING TO FLOOR DRAINS SHALL BE "PEX'. NO JOINTS IN PIPING BELOW FLOOR ALLOWED. 16. VALVES DOMESTIC WATER: a. BALL VALVES — NIBCO FIGURE S—FP-600 SERIES FULL PORT BALL VALVES, TWO PIECE BODY, CHROME PLATED BALL, TFE SEATS, 600 PSI WOG RATING, BLOW OUT STEM, SOLDERED CONNECTIONS OR EQUAL b. CHECK VALVES — NIBCO NO. S-413, CLASS 125 BRONZE SWING CHECK VALVE WITH BRONZE DISC OR EQUAL. GAS VALVES: a. 2" AND SMALLER — JOMAR MODEL T-100 FULL PORT AGA/CGA LISTED OR EQUAL b. 2-1/2" AND LARGER — HOMESTEAD FIG. NO. 602 FLANGED LUBRICATED PLUG VALVE OR EQUAL. 10. ALL PARTS OF THE PLUMBING SYSTEMS AND ASSOCIATED EQUIPMENT SHALL BE PRESSURE TESTED AND ADJUSTED TO WORK PROPERLY AND SHALL BE LEFT IN 17.IDENTIFICATION AND VALVE TAGS GOOD OPERATING CONDITION TEST PRESSURE SHALL BE AS FOLLOWS: a. SOIL, WASTE AND VENT PIPE b. DOMESTIC WATER PIPE c. GAS PIPE HYDROSTATIC OR: 5 PSIG — 2 HOURS 150 PISG — 4HOURS 25 PSIG — 4HOURS 12. THE PLUMBING CONTRACTOR GUARANTEES BY HIS ACCEPTANCE OF THE CONTRACT THAT ALL WORK INSTALLED WE BE FREE FROM ANY AND ALL DEFECTS IN THE WORKMANSHIP AND/OR MATERIALS AND THAT ALL APPARATUS WILL DEVELOP CAPACITIES AND CHARACTERISTICS SPECIFIED AND THAT IF, DURING THE PERIOD OF (1) ONE YEAR OR AS OTHERWISE SPECIFIED FROM THE DATE OF CERTIFICATE OF COMPLETION AND ACCEPTANCE OF WORK, ANY SUCH DEFECTS IN WORKMANSHIP, MATERIAL OR PERFORMANCE APPEAR, HE WILL WITHOUT COST TO THE OWNER, REMEDY SUCH DEFECTS WITHIN A REASONABLE TIME TO BE SPECIFIED IN NOTICE FROM THE ARCHITECT. IN DEFAULT THEREFOR, OWNER MAY HAVE SUCH WORK DONE AND CHARGE COST TO THE PLUMBING CONTRACTOR. 13. PIPE HANGERS AND SUPPORTS: a. ALL PIPING, EXCEPT PIPING WHICH IS IN CONCEALED LOCATIONS SHALL BE IDENTIFIED WITH PIPE MARKERS MADE OF SELF—ADHESIVE, INDOOR/OUTDOOR GRADE VINYL CONFORMING TO ASME/ANSI a13.1-2007 STANDARDS AND MEET ANSI SPECIFICATIONS FOR BACKGROUND AND LETTER COLORS, LENGTH OF FIELD AND LETTER HEIGHT. FLOW DIRECTIONAL ARROW TAPE SHALL BE USED WITH PIPE MARKERS TO INDICATE DIRECTION OF FLOW. b. ALL VALVES SHALL DESIGNATED BY NUMBERS AND LETTER CAREFULLY COORDINATED WITH A VALVE CHART. VALVE TAGS SHALL BE 19 GAUGE SOLID BRASS, 1-1/2" ROUND WITH BLACK INK IN FILL COLO. TAGSSHAH BE ATTACHED TO VALVES WITH SOLID BRASS JACK CHAIN OR BRASS "S" HOOKS. c. EQUIPMENT NAMEPLATES SHALL BE PLASTIC SELF—ADHESIVE TYPE WITH WHITE LETTERS ON BLACK BACKGROUND, MINIMUM PLATE SIZE 1 "X3'X063 THICK. NAMEPLATE IDENTIFICATION SHALL BE THE SAME AS THE SHOWN ON THE CONTRACT DRAWINGS AND SPECIFICATIONS. d. THE ABOVE PRODUCTS AS MANUFACTURED BY SETON OR MARKING SERVICES, INC. ARE ACCEPTABLE. L I SUBMITTED FOR PERMIT 16/15/18 I I I REV I DESCRIPTION I DATE I BY S e ry i c e s � England Mechanical ENGINEERS & CONTRACTORS 166 TUNNEL ROAD, VERNON, CONNECTICUT 06066 tpl. 860.871.1111 fax. 860.871.9154 website: www.nemsi.com . Y"• • 9 - 55 GERBER BUILDING SOUTH WINDSOR, CONNECTICUT PLUMBING FLOOR PLAN r Wow ft DRAWN BY: FSI CHECKED BY: M EM DRAWNG NO. SCALE »=1 v_O,r DATE- 1/8 6_1 5_18 P-2 ONA �l �e/1 f t f 1 t I l llit PROJECT N0. MP 18884 SHEET 2 OF 2