Loading...
HomeMy WebLinkAbout88 NUTMEG RDQ O m 0 m .1 z R CONCRETE PAD AND ROOF STRUCTURE LIST OF DRAWINGS SHEET NO. SHEET TITLE COVER C-101 EXISTING SITE PLAN C-102 PROPOSED SITE PLAN C-103 SITE DETAILS S-001 STRUCTURAL GENERAL NOTES S-101 STRUCTURAL FOUNDATION AND ROOF PLANS S-201 STRUCTURAL WALL ELEVATIONS S-301 STRUCTURAL SECTIONS AND DETAILS SHEET 1 OF 2 S-302 STRUCTURAL SECTIONS AND DETAILS SHEET 2 OF 2 PROJECT NO: E5012 001 SEPTEMBER, 202 Y 4� SITE - ��: it 6 South 011(avr 0% `r+ 1f fa ftCe 01 rssFaSiage fill Pat LOCATION MAP NO SCALE PREPARED BY: Tighe&Bond Engineers I Environmental Specialists PREPARED FOR: EVOQUA WATER TECHNOLOGIES 88 NUTMEG ROAD -SOUTH SOUTH WINDSOR, CONNECTICUT ne� CC) SCCP DECEIVED SEP 2 8 2022 South Windsor Buiiding Dept ,,s Cenifleo u•.. tn,o pion one �peertrc �a:...., •� trt vies of the proposed building or alttrael-+nx to t+ rooted as wgethor with amendments stated In application ��. 'lied with plea and I agree to comply with all zorrrt luiiding and etato laws and such orders as r4,.4 �- .ssued by the Qullding Departx."ont during penoe,rc, .t th19 application and finol Isatta"00 at e aat.nh. signed rhis plany.,jr%6;6=C6n (--bl"'t to Cho co" �rdon anicgtllatina bulldtnc cornp .onditionally Apptrotre6 Thes- ISSUED FOR CONSTRUCTION COMPLETE SET 9 SHEETS I Tighe&Bond N Engineers I Environmental Specialists U w T m a rn M N N N N O O N IN k6 ko N N p- rn a) Ln >O 10-0 ICU o _1 a i 1 D V D n CI 51 0I c 0 n 2 i I - REMOVE EXISTING CURBING AND PAVEMENT M COEALTy T 1 SAWCUT EXISTING PAVEMENT 1 si �O7'15, E 24' WIDE DRIVE SAWCUT EXISTING I I ' 2" TREE PAVEMENT 2" TREE REMOVE EXISTING WI CCU O O W Z z W Q z CURBING AND PAVEMENT VED AREA 1 1 1 1 II 1 I I �I REMOVE EXISTING CURBING AND PAVEMENT I I /CUT EXISTING EMENT I I f 1 _ BI TUMIN US PA ED AR 415.00, I I I 11 ` N65-_� I NOTE: M. G REAL Ty I 1. NO SURVEY WAS PERFORMED AND BASE MAP WAS DEVELOPED USING DRAWINGS TITLED 407 3 "U.S. FILTER ADDITION AND RENOVATIONS", SHEET 2, PREPARED BY DESIGN PROFESSIONALS, INC., DATED APRIL 22, 1996 AND "NUTMEG COMMERCIAL CENTRE", SHEET 8, PREPARED BY FUSS & O'NEILL, INC., DATED DULY 1987.' I I I k w 0 20' 40' SCALE: 1" = 20' CONNF� \EL HOZ Ti Is73 09/1 t20 Chemical Storage Tank Concrete Pad & Roof Structure Evoqua Water Technologies South Windsor, Connecticut 0 9/26/2022 ISSUED FOR CONSTRUCTION MARK DATE DESCRIPTION PROJECT NO: E5012-001 DATE: 11/13/2018 FILE: E5012-001-C-101.dwg DRAWN BY: D.BISHOP CHECKED: TG APPROVED: CSF EXISTING SITE PLAN SCALE: AS NOTED C-101 SHEET 2 OF 9 U w_ m E a rn CI 'I .I 0 O U) O O W Z z I M G N/F RCAi r, LOT / AR WI (20) EXISTING PARKING SPACES TO REMAIN I I I I 1illrDER\v iOU.Ci 1r.0 V/ERln:V E rA�R EA TOTAL SITE AREA = 123,804 SF EXISTING BUILDING AREA = 31,235 SF EXISTING IMPERVIOUS AREA = 55,920 SF EXISTING TOTAL IMPERVIOUS = 87,155 SF (70.4%) EXISTING OPEN SPACE = 36,649 SF (29.6%) PROPOSED NEW IMPERVIOUS = 982 SF PROPOSED IMPERVIOUS REMOVAL = 1,711 SF TOTAL PROPOSED IMPERVIOUS = 86,426 SF (69.8%) PROPOSED OPEN SPACE = 37,378 SF (30.2%) 7nNINr- TARE ZONING DISTRICT: INDUSTRIAL ZONE DIMENSIONAL REQUIREMENTS: REQUIRED EXISTING PROVIDED SETBACKS: FRONT YARD 35 FT 76 FT 76 FT SIDE YARD 10 FT 42 FT 42 FT BACK YARD 25 FT 78 FT 78 FT MIN LOT AREA 30,000 SF 123,804 SF 123,804 SF MAX IMPERVIOUS COVERAGE 65% 70.4% 69.8% MAX LOT COVERAGE 50% 25% 25% MIN OPEN SPACE 50% 29.6% 30.2% PARKING REQUIREMENTS: WAREHOUSE USE: 1 SPACE PER 1,250 GROSS SQUARE FEET OF FLOOR AREA 1 SPACE PER EMPLOYEE DURING TYPICAL SHIFT EXISTING WAREHOUSE = 31,235 GSF REQUIRED PARKING = 31,235 GSF X 1 SPACE PER 1,250 GSF = 25 SPACES = 13 EMPLOYEES X 1 SPACE PER EMPLOYEE = 13 SPACES = 38 TOTAL SPACES REQUIRED EXISTING PARKING = 30 TOTAL PROPOSED PARKING I = 38 SPACES I LOAM AND SEED I I V I I PARKING S+ALL STRIPING TO BE 4" WHITE LINE (TYP.) I i i9neaDona N Engineers I Environmental Specialists uuurr,,�t 2973742L- ``. . f_22" 09/277i20 , IA I" tiW''� Chemical Storage Tank Concrete Pad & Roof Structure Evoqua Water t:u I I IUIUy I South Windsor, Connecticut I , _ _.. _ BI TUI.O.. IN�U. .S... .P. A ED.. _ AREA ... ... - - — YARD YARD I I 0 9/26/2022 ISSUED FOR CONSTRUCTION 00' 4/5.MARK DATE DESCRIPTION � _ ( PROJECT NO: E5012-001 (10) EXISTING PARKING N 65 pj"/ — _ _ _ — _ ` — SPACES TO REMAIN DATE: 11/13/2018 _ _ I FILE: E5012-001-C-102.dwg DRAWN BY: D.BISHOP _ I CHECKED: TG APPROVED: CSF NOTES: 3. ROOF GUTTER SYSTEM TO BE TIED INTO EXISTING SITE DRAINAGE. 1. NO SURVEY WAS PERFORMED AND BASE MAP WAS DEVELOPED USING DRAWINGS TITLED 4. ZONING INFORMATION OBTAINED FROM "TOWN OF SOUTH WINDSOR ZONING // G "U.S. FILTER ADDITION AND RENOVATIONS", SHEET 2, PREPARED BY DESIGN REGULATIONS", DATED MARCH 27, 2022 AND "TOWN OF SOUTH WINDSOR ZONIN`6)M8-P',y PROFESSIONALS, INC., DATED APRIL 22, 1996 AND "NUTMEG COMMERCIAL CENTRE", SHEET DATED 2018. - - 8, PREPARED BY FUSS & O'NEILL, INC., DATED JULY 1987.' 5. ON APRIL 4, 1996, APPLICATION #2316-96 WAS APPROVED AND A VARIANCE OF SECTION 2. SUMP PITS IN EACH CONTAINMENT ZONE TO BE MANUALLY PUMPED OUT AND DISPOSED OF 10.2 OF THE ZONING BYLAW WAS GRANTED TO ALLOW 70% IMPERVIOUS COVERAGE ON THE I AS REQUIRED BY CTDEEP. PROPERTY LOCATED AT 88 NUTMEG ROAD SOUTH. 0 20' 40' SCALE: 1" = 20' PROPOSED SITE PLAN SCALE: AS NOTED C-102 SHEET 3 OF 9 POST CONCRETE F] GATE POST PORTLAND CEMENT CONCRETE E 0 UU) w �;o , m0 E a N 0 M > W � N N .-1 0Nw N N W N a r'1 Q) o m° CZ5 U) Iv 0)1� M -of- 21 EL 21' POST TOP CHAIN LINK FABRIC, TOP SELVAGE v-CORNER ARM F TWISTED 450 B/W ARM RAIL TIE 1.66" OD BRACE RAIL OTTOM SELVAGE KNUCKLED (3) STRANDS OF BARBED WIRE, EA CONSISTING OF LINE WIRE W/ 4 PT LINE POE LINE F " I I 11 I I 11 TURNBUCKLE ADJUSTABLE III TRUSS ROD III TENSION BAR I I I I I I I I B�' ��f11L I I N III I I I I I I I I�� I III �• I I PORTLAND I I I CEMENT CONCRETE LJ I I u I I u I (PER MASS. HIGHWAY DEPT. I u J L_ J L_ J STANDARD SPECIFICATION) L_ J ROUND END & ��nnlrn n�rr 10'-0" MAX. SPACING NOTES: 1. FOOTING WIDTH TO BE (4)X POST WIDTH. NOTES: 1. FOOTING WIDTH TO BE (4)X POST WIDTH. 2. GATES MAY BE MANUALLY OPERATED. FLC WORK PLAN CHAIN LINK FENCE NO SCALE GATE ELEVATION DOUBLE SWING GATE NO SCALE )D STAKES*-TYP. AREA TO BE PROTECTED STRAW WATTLES OR MULCH LOGS 211x2"x2'-011 — WOOD STAKES FOR WATTLES* M WORK ZONE a, ERROSION CONTROL BARRIER NO SCALE *-STAKES TO BE SPACED AT 4-5' O.C. STAGGER STAKES BETWEEN STRAW WATTLES AND SILT FENCE SECTION AREA TO BE PROTECTED DNCRETE FILLED 4TE POST FAIN LINK FABRIC ATE LATCH WITH :OVISION FOR kDLOCK 9" SQ GATE FRAME YP 4 SIDES) - 2 1/2" 20" AT GATE POST CONTAINMENT BASE SLAB AND WALL 6" 3'-0" W.W.F. 6x6 W4xW4 2" TYPE VI XPS RIGID INSULATION BOARD - 4" CONC. SIDEWALK 811 PROCESSED GRAVEL SUB -BASE NOTES: 1. WALK TO HAVE 1/4" RADIUS TOOLED DUMMY JOINT 1/4 OF THE THICKNESS OF THE SIDEWALK IN DEPTH EVERY 5 L.F. OF WALK. 2. WALK TO HAVE 1/2" WIDE NON -EXTRUDING PREFORMED EXPANSION JOINT EVERY 20 L.F. OF WALK. CONCRETE SIDEWALK NO SCALE BITUMINOUS CONCRETE TOP COURSE BITUMINOUS CONCRETE BINDER & BASE PROCESSED —� GRAVEL BASE MODIFIED BITUMINOUS BERM -TYPE "A" NO SCALE NIP! .&�_ n-w_.r ii9neaDona Engineers I Environmental Specialists •,�SEL H04 . T/0 29737 09/27/20 o C 0 NNF�,' • l CENS �0'•.• 16857 .� �� . )9/27/ 0221m1IU Evoqua Water Technologies South Windsor, Connecticut 0 9/26/2022 ISSUED FOR CONSTRUCTION MARK DATE DESCRIPTION PROJECT NO: E5012-001 DATE: 11/13/2018 FILE: E5012-001-C-103.dwg DRAWN BY: D.BISHOP CHECKED: TG APPROVED: CSF SITE DETAILS SCALE: AS NOTED C-103 SHEET 4 OF 9 N co N .--i O O N N � W N � a LO -0E °10 ru �^ o �a 6 D n D v 1. 31 Io 0 n D D 10 VI 0 c 0 n C o� GENERAL G1 STRUCTURAL WORK SHALL CONFORM TO MASSACHUSETTS STATE BUILDING CODE, LATEST EDITION, INCLUDING MOST RECENT ADDENDA, AND CONTRACT DOCUMENTS. IN CASE OF CONFLICT, MOST STRINGENT REQUIREMENT SHALL GOVERN. G2 CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS RELATED TO THIS PROJECT. G3 CONTRACTOR SHALL EXAMINE DRAWINGS FOR ALL TRADES FOR THE VERIFICATION OF LOCATION AND DIMENSIONS OF ALL CHASES, INSERTS, OPENINGS, SLEEVES AND OTHER PROJECT REQUIREMENTS NOT SHOWN ON THE STRUCTURAL DRAWINGS. G4 PROVIDE CAULKING AT ALL CONTROL JOINTS. PROVIDE COMPRESSIBLE FILLER AND SEALANT AT ALL EXPANSION AND ISOLATION JOINTS. G5 PROVIDE PREMOLDED JOINT FILLER WHERE SLABS ON GRADE ABUT WALLS AND COLUMNS. REINFORCEMENT R1 DETAILING, FABRICATION, AND ERECTION OF REINFORCEMENT, UNLESS OTHERWISE NOTED, SHALL CONFORM TO ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318)" AND ACI "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315)", LATEST EDITION. R2 STEEL REINFORCEMENT UNLESS OTHERWISE SHOWN SHALL CONFORM TO ASTM A615 GRADE 60 KATKITNAI IAA /VTCI 11 STRENGTH ff1 r\rin nC`T, I"IllVll"IVI"1 lT1CLV JIRCIVVI(-1 - VV,VVV r�i). R3 WELDED WIRE FABRIC REINFORCEMENT SHALL CONFORM TO: ASTM A185. R4 PROVIDE AND SCHEDULE ON SHOP DRAWINGS, ALL NECESSARY ACCESSORIES TO HOLD REINFORCEMENT SECURELY IN POSITION: MINIMUM REQUIREMENTS SHALL BE: HIGH CHAIRS, 4'-0" ON CENTER, #5 SUPPORT BAR FOR HIGH CHAIRS, SLAB BOLSTERS, 3'-6" ON CENTER, ALL WIRE CHAIRS AND BOLSTERS TO BE PLASTIC TIPPED. R5 THE CONCRETE PROTECTIVE COVERING FOR REINFORCEMENT SHALL BE AS FOLLOWS, UNLESS OTHERWISE SHOWN BUT IN NO CASE SHALL THE COVER BE LESS THAN THE BAR DIAMETER: (A) CAST -IN -PLACE CONCRETE. EXPOSED TO EARTH, NOT EXPOSED TO EARTH, WATER, OR WEATHER WATER, OR WEATHER (A) SLAB ON GRADE 3 INCHES 2 INCHES (B) COLUMN TIES 2 INCHES 1 1/2 INCHES (C) COLUMN MAIN REBARS 2 1/2 INCHES 2 INCHES (D) BEAM STIRRUPS 2 INCHES 1 1/2 INCHES (E) BEAM MAIN REBARS 2 1/2 INCHES 2 INCHES (F) SLAB'S #3 TO #5 INCL'S 1 1/2 INCHES 3/4 INCHES (G) SLABS #6 TO #11 INCL'S 2 INCHES 3/4 INCHES (H) WALL #11 BAR OR SMALLER 2 INCHES 3/4 INCHES (I) NOTE: MAXIMUM DEVIATION FROM THESE REQUIREMENTS SHALL BE +1/4" FOR SECTIONS TEN (10) INCHES OR LESS, AND +1/2" FOR SECTIONS OVER TEN (10) INCHES THICK. R6 WHERE CONTINUOUS BARS ARE CALLED FOR THEY SHALL BE RUN CONTINUOUSLY AROUND CORNERS AND LAPPED AT NECESSARY SPLICES OR HOOKED AT DISCONTINUOUS ENDS. R7 WHERE REINFORCEMENT IS NOT SHOWN ON DRAWINGS, PROVIDE REINFORCEMENT IN ACCORDANCE WITH APPLICABLE TYPICAL DETAILS OR SIMILAR TO THAT SHOWN FOR MOST NEARLY SIMILAR SITUATIONS, AS DETERMINED BY THE ENGINEER. IN NO CASE SHALL REINFORCEMENT BE LESS THAN MINIMUM REINFORCEMENT PERMITTED BY THE APPLICABLE CODES, NOR LESS THAN THE FOLLOWING: (A) BEAM STIRRUPS-#3 @ 12" OC (B) BEAM STIRRUP SUPPORTS-1-#5 @ EACH STIRRUP BEND (C) FACE REINFORCEMENT IN BEAMS OR PORTIONS OF BEAMS-#4 @ 12" EF (D) STRUCTURAL SLABS-.0028 GROSS CONCRETE AREA IN EACH DIRECTION (D) STRUCTURAL WALLS-.0028 GROSS CONCRETE AREA IN EACH DIRECTION R8 WHERE REINFORCEMENT IS CALLED FOR IN SECTION, REINFORCEMENT IS CONSIDERED TYPICAL WHEREVER THE SECTION APPLIES. R9 REINFORCEMENT SHALL BE CONTINUOUS THROUGH ALL CONSTRUCTION JOINTS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. R10 WELDED WIRE FABRIC SHALL LAP 12" OR TWO SPACES, WHICHEVER IS LARGER, AND SHALL BE WIRED TOGETHER. R11 REINFORCEMENT COUPLER SPLICES SHALL BE MECHANICAL DEVICES CAPABLE OF TRANSMITTING THE ULTIMATE TENSILE AND COMPRESSIVE STRENGTH OF THE BAR. R12 INSTALLATION OF REINFORCEMENT SHALL BE COMPLETED AT LEAST 24 HOURS PRIOR TO SCHEDULED CONCRETE PLACEMENT. NOTIFY ENGINEER OF COMPLETION AT LEAST 24 HOURS PRIOR TO SCHEDULED COMPLETION OF PLACEMENT OR REINFORCEMENT. R13 REINFORCEMENT SHALL BE SET BEFORE PLACING CONCRETE. SETTING ANY REINFORCEMENT INTO WET CONCRETE IS PROHIBITED. FOUNDATIONS F1 NO CONCRETE SHALL BE PLACED IN WATER OR ON FROZEN GROUND. F2 BOTTOM OF FOUNDATION ELEVATIONS GIVEN ON PLANS ARE TO BE CONSIDERED MINIMUM DEPTHS. CONTRACTOR SHALL HAVE FURTHER EXCAVATION AS REQUIRED TO REACH GOOD BEARING. F3 ALL EXCAVATIONS FOR FOOTINGS SHALL BE FINISHED BY HAND FOR THE LAST 611. F4 ALL FINISHED EXCAVATIONS SHALL BE INSPECTED BY THE ENGINEER BEFORE ANY CONCRETE IS PLACED. F5 ALL BACKFILL UNDER OR ADJACENT TO ANY PORTION OF THE STRUCTURES SHALL BE COMPACTED IN 6" LIFTS. SEE SPECIFICATIONS. F6 REMOVE UNSUITABLE FILL AND/OR IMPROVE THE SUBGRADE PER SPECIFICATION REQUIREMENTS. BACKFILL WITH COMPACTED STRUCTURAL (GRANULAR) FILL UP TO THE UNDERSIDE OF THE BUILDING SLABS. SEE SPECIFICATIONS. ROUGH CARPENTRY R1 INSTALL SHEATHING PERPENDICULAR TO ROOF DECKING. R2 PROVIDE STAGGERED JOINTS IN PLYWOOD, PARALLEL TO ROOF DECKING. R3 FASTEN ROOF SHEATHING TO ROOF DECK WITH #10 DRILL POINT FLAT HEAD SCREW 12" ON CENTER AND 6" ON CENTER AT SHEATHING JOINTS. CONCRETE C1 CONCRETE WORK SHALL CONFORM TO THE LATEST EDITIONS OF THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318), AND SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING (ACI 301). C2 CONCRETE SHALL BE CONTROLLED CONCRETE, PROPORTIONED, MIXED AND PLACED UNDER THE SUPERVISION OF AN APPROVED CONCRETE TESTING AGENCY OR THE ENGINEER. C3 CONCRETE SHALL BE NORMAL WEIGHT CONCRETE AND SHALL HAVE A COMPRESSIVE STRENGTH OF 4500 PSI AT 28 DAYS, UNLESS OTHERWISE NOTED AND SHALL BE AIR ENTRAINED (SEE SPECS) C4 THE USE OF CONSTRUCTION JOINTS WHERE SHOWN ON THE DRAWINGS IS MANDATORY. OMISSIONS; ADDITIONS OR CHANGES SHALL NOT BE MADE EXCEPT WITH THE SUBMISSION OF A WRITTEN REQUEST TOGETHER WITH DRAWINGS OF THE PROPOSED JOINT LOCATIONS FOR APPROVAL OF THE STRUCTURAL ENGINEER. C5 WHERE CONSTRUCTION JOINTS ARE NOT SHOWN, DRAWINGS SHOWING LOCATION OF CONSTRUCTION JOINTS AND CONCRETE PLACING SEQUENCE SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO PREPARATION OF THE REINFORCEMENT SHOP DRAWINGS. C6 CONCRETE SLABS SHALL BE CAST SO THAT THE SLAB THICKNESS IS AT NO POINT LESS THAN THAT INDICATED ON THE DRAWINGS. C7 CONCRETE SLABS AND WALLS SHALL BE CAST ALTERNATELY OR IN A CHECKERBOARD FASHION SO THAT ADJACENT SECTIONS ARE PLACED NO SOONER THAN THREE DAYS APART. AT LEAST TWO DAYS MUST ELAPSE AFTER PLACING CONCRETE IN WALLS BEFORE PLACING FLOOR SYSTEM SUPPORTED THEREON. C8 CONCRETE SHALL BE PLACED WITHOUT HORIZONTAL CONSTRUCTION JOINTS EXCEPT WHERE SHOWN OR NOTED. C9 EXPOSED EDGES OF CONCRETE ELEMENTS SHALL HAVE CHAMFERED CORNERS. C10 ONLY CRITICAL CONSTRUCTION JOINTS ARE SHOWN. SEE SPECIFICATIONS FOR REQUIRED MAXIMUM SPACING OF CONSTRUCTION JOINTS. BAR SIZE DESIGNATION DEVELOPMENT LENGTH (INCHES) SPLICE LENGTH (INCHES) ENGLISH Ld CLASS B CLASS B TOP BARS #3 15 19 25 #4 19 25 33 #5 24 31 40 #6 29 37 48 #7 42 54 70 #8 48 62 81 #9 54 70 91 #10 61 79 103 REBAR SPLICE LENGTH SCHEDULE NOTES: 1. IF CLEAR SPACING BETWEEN THE REBARS IS LESS THAN THREE BAR DIAMETERS, OR IF COVER IS LESS THAN TWO BAR DIAMETERS, INCREASE THE SPLICE LENGTH BY AN ADDITIONAL 50%. 2. IF EPDXY COATED REBAR IS USED, INCREASE THE SPLICE LENGTH BY AN ADDITIONAL 50%. 3. IF LIGHTWEIGHT CONCRETE IS USED, INCREASE THE SPLICE LENGTH BY AN ADDITIONAL 30%. 4. THE MINIMUM REBAR SPLICE LENGTH SCHEDULE IS BASED ON F'c= 4,000 PSI AND Fy= 60,000 PSI. ADJUST FOR OTHER STRENGTHS USING ACI-318. S. FOR HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW, INCREASE THE DEVELOPMENT LENGTH BY AN ADDITIONAL 30%. 6. WHEN BARS OF DIFFERENT SIZE ARE LAP SPLICED, THE SPLICE LENGTH SHALL BE THE LARGER OF EITHER THE DEVELOPMENT LENGTH OF THE LARGER BAR OR THE SPLICE LENGTH OF THE SMALLER BAR. CHEMICAL RESISTANT WATERSTOP (REQUIRED AT WA TYPICA, SPLICE LENGTH U' BARS -SAME SIZE & SPACING AS WALL/SLAB REINFORCING (TYPICAL ALL SIDES OF OPENING) INTERRUPTED BAR (NOTE 1) ADDITIONAL BAR (NOTE 2) ROUGHEN SURFACE OF SLA #4 BARS AT 12" OC, EW s" CHAMFER (TYP) NOTE: COORDINATE THE SIZE OF THE TANK PAD WITH THE TANK SHOP DRAWING T/6 < 3" MAX. f\LVLL I VVl 1 I I f\\JLJ & SEALANT (BOTH SIDES WALLS ONLY) CONSTRUCTION JOINT NO SCALE W + 2(Ld (NOTE 3) TANK PAD DETAIL NO SCALE #5 BAR x 5'-0" EACH FACE (ALL CORNERS OF OPENING) ADDITIONAL BAR (NOTE 2) M w F- O z WHERE NOT POSSIBLE TO MAINTAIN SPECIFIED DISTANCE PAST OPENING, HOOK REINFORCING BARS NOTES: 1. FOR SLAB OR WALL APPLICATION WITH A CONCRETE THICKNESS LESS THAN 12 INCHES, 180° OR 90°, HOOK BARS MAY BE USED IN LIEU OF ' U' BARS. 2. PROVIDE ADDITIONAL BARS USING NOT LESS THAN ONE HALF OF INTERRUPTED BARS AT EACH SIDE OF OPENING AT 3" ON CENTER. 3. FOR TOP BARS IN SLAB, INCREASE DEVELOPEMENT LENGTH BY 30% TYPICAL REINFORCING AT OPENINGS IN CONCRETE WALLS AND SLABS NO SCALE SLAB ON GRADE C� CHEMICAL RESISTANT WATERSTOP REQUIRED AT ALL JOINTS /� REGLET WITH BACKER / ROD & SEALANT REGLET WITH BACKER ROD & SEALANT NOTE: CONCRETE IS PLACED MONOLITHICALLY ON BOTH SIDES OF ALL CONTRACTION JOINTS CONCRETE WALL CONTRACTION JOINT NO SCALE SPLICE LENGTH U' BARS -SAME SIZE & SPACING AS WALL/SLAB REINFORCING (TYPICAL ALL SIDES OF OPENING) INTERRUPTED BAR (NOTE 1) ADDITIONAL BAR (NOTE 2) D + 2(Ld) (NOTE 3) #5 BAR x 5'-0" EACH FACE (ALL CORNERS OF OPENING) ADDITIONAL BAR (NOTE 2) M w O z WHERE NOT POSSIBLE TO MAINTAIN SPECIFIED DISTANCE PAST OPENING, HOOK NOTES: REINFORCING BARS 1. FOR SLAB OR WALL APPLICATION WITH A CONCRETE THICKNESS LESS THAN 12 INCHES, 180° OR 90°, HOOK BARS MAY BE USED IN LIEU OF ' U' BARS. 2. PROVIDE ADDITIONAL BARS USING NOT LESS THAN ONE HALF OF INTERRUPTED BARS AT EACH SIDE OF OPENING AT 3" ON CENTER. 3. FOR TOP BARS IN SLAB, INCREASE DEVELOPEMENT LENGTH BY 30%. TYPICAL REINFORCING AT OPENINGS IN CONCRETE WALLS AND SLABS NO SCALE Tighe&Bond rn_:.___ _ i rn..:.._n�__na._I r___:_1:_,._ C�1C�If1CCf5 � C�1VIfV�lfile(1Cdl JFJ@GIdUSLS C ON . C o, Q� ��\G FR Al FNcyT/�G� `i,�,ll,il II171!/l, pF CONN£ 1686 Chemical Storage Tank Concrete Pad & Roof Structure Evoqua Water Technologies South Windsor, Connecticut 0 9/26/2022 ISSUED FOR CONSTRUCTION MARK DATE DESCRIPTION PROJECT NO: E5012-001 DATE: 11/13/2018 FILE: E5012-001-S-001.dwg DRAWN BY: D.BISHOP CHECKED: TG APPROVED: CSF STRUCTURAL GENERAL NOTES SCALE: AS NOTED S-001 SHEET 5 OF 9 fl. 0 to 0o 0 m E 0 0 2 O N � N 00 N N � N �U0 �O �-0 _ja CROSSOVER LADDER ACCESS, SEE TYPICAL DETAILS ON DWG 9" S-302 (TYP FOR 2) —{ TOP OF 12" BASE SLAB AT EL. 72.50, SEE FLOOR TOPPING PLAN FOR FLOOR SLOPE REQUIREMENTS FOR CORNER WALL PIER REINFORCING SEE TYPICAL DETAIL ON DRAWING S-302 (TYP. 4 PLACES) TOP OF WALL AT EL. 79.50' TOP OF TANK PAD AT EL. 73.00' N co 3'-0" WIDE r' SIDEWALK AT EL. 72.50 (TYP) CONTROL JOINT IN WALLS ONLY (EAST, WEST AND CENTER)-4 18'-6" V-6" SQ. SUMP, BOTT. AT EL. 71.17' A SE- 3 017(TYP. FOR 2) S-301 TOP OF WALL AT EL. 79.50'-, L 10" (TYP.) B S-301 C 3 C 16'-6" 9TI FOR CENTER WALL PIER REINFORCING SEE TYPICAL DETAIL ON DRAWING S-302 T-0" WIDE SIDEWALK (TYP. 2 PLACES) AT EL. 72.50 TOP OF WALL (TYP) ////—AT EL. 76.50' I 9,000 GAL STORAGE TANK 10" (TYP.) TOP OF 12" BASE SLAB AT EL. 72.50, SEE FLOOR TOPPING PLAN FOR FLOOR SLOPE REQUIREMENTS Il TOP OF TANK PAD AT EL. 73.00' m ib T is o w 3'-0" WIDE '-' `V Q SIDEWALK m AT EL. 72.50 (TYP) TOP OF WALL AT EL. 76.50' rE Tighe&Bond y Engineers I Environmental Specialists 1'-6" SQ. SUMP, BOTT. AT EL. 71.17' B C (TYP. FOR 2) 18'-6" 16'-6" 5�../ EDGE OF BASE ° - - - - - - - - - - - - - - ° ° - SLAB - - - - °- - - ° ° - - - - --°' °° - - - - - - Eo ° 0) FOR TYPICAL SIDEWALK TOP OF WALL TOP OF WALL I Df FOR TYPICAL BASE EL.72.88 EL.72.91 EL.72.88 EL.72.88 EL.72.91 EL.72.88 DETAIL AND REQUIREMENTS AT EL. 79.50' AT EL. 76.50' PLATE AND ANCHOR - SEE CIVIL DRAWING C-103 611 36'-6" 611 BOLT PATTERN SEE H \ DETAILS ON DWG S-302 30'-0" rb 37'-6" (TYPICAL 6 PLACES) (BASE SLAB) /�� 77 // , \�ICONSTRUCTION EXISITING BUILDING JOINT IN EXISTING BUILDING `-EDGE OF EXISTING PAVEMENT EDGE OF BASE SLAB BASE SLAB AND WALLS FOUNDATION PLAN FLOOR TOPPING PLAN NOTES: 1/4" = 1'-0" LEGEND 1/4" = V-0" 1. FOR TYPICAL CONSTRUCTION AND CONTROL JOINT DETAILS SEE INDICATES DIRECTION OF FLOOR SLOPE (1/8"/FT MIN.) DRAWING S-001. 2. ALL CONSTRUCTION AND CONTROL JOINTS SHALL BE COMPLETE WITH CHEMICAL RESISTANT WATERSTOPS. CLOSURE STRIP h 0.1 � C1, o EXTEND METAL DECK TO PROVIDE 4" OVERHANG FROM CENTERLINE OF FRAMING. TYPICAL ALL 4 SIDES. N bo rH CLOSURE STRIP WITH EAVE FLASHING B C STANDING SEAM / 18'-6" 16'-6" METAL ROOFING ROOF EAVE TRIM � //« ROOFING FELT G I -' — W >:— 5/8" EXTERIOR GRADE CDX PLYWOOD � �h I rnh GUTTER AND DOWNSPOUTS , �4) TOP OF STEEL ON COLUMN LINE 2 1 1/2", 22 GAGE METAL AT EL. 91.00' DECKING, SECURE TO o o ROOF BEAMS PER MANUF 8x15 =� _� _ -- _� — — — — — — — W8x15 — — �— — — — - METAL FASCIA RECOMMENDATIONS I L PROVIDE FASCIA j L5x5x7/16 VERT. j I STANDOFF CLIPS I K-STYLE BRACING I i I W8 ROOF BEAM 40 do do _ CONTINUOUS DRIP EDGE H FLASHING, PROVIDE LENGTH "- z z TO MATCH RAKE FACIA p a O Q 0 C.� SECTION F do do I NO SCALE -- j L6x6x5/16 VERT. w w j l STANDING SEAM ,l X-BRACING X O L6x6x5/16 VERT. j X METAL ROOFING o � X-BRACING o ROOF RAKE TRIM ROOFING FELT do do i I 5/8" EXTERIOR GRADE CDX PLYWOOD L5x5x7/16 VERT. ! i I TOP OF STEEL ON X-BRACING I COLUMN LINE "1" AT EL. 91.75 DECKING, SECURE TO METAL ROOF BEAMS PER MANUF ' - - METAL FASCIA RECOMMENDATIONS — — — — — — — W8x15 — — . _�_ — . !_ —! — '— — — — W8x15 — — — — — �� PROVIDE FASCIA +RS +RS c'+ STANDOFF CLIPS F ROOF FRAMING PLAN W10 ROOF BEAM 1/4" = 1'-0" CONTINUOUS DRIP EDGE NOTES: - FLASHING 1. TOP FLANGE OF W8x15 ROOF BEAMS TO MATCH ROOF SLOPE TO FULL SUPPORT ROOF PANELS. SECTION H 2. TOP OF COLUMNS TO BE HELD SHORT BY 1/2" TO AVOID CONTACT NO SCALE -- WITH UNDERSIDE OF ROOF PANELS. STANDING SEAM METAL ROOFING ROOFING FELT 5/8" EXTERIOR GRADE CDX PLYWOOD ---- 1 1/2", 22 GAGE METAL DECKING, SECURE TO ROOF BEAMS PER MANUF RECOMMENDATIONS PROVIDE FASCIA STANDOFF CLIPS W8 ROOF BEAM �� CONTINUOUS DRIP EDGE FLASHING, PROVIDE LENGTH TO MATCH RAKE FACIA SECTION G NO SCALE -- GUTTER HANGERS PER GUTTER MANUF. RECOMMENDATIONS GUTTER SYSTEM METAL FASCIA 0 2' 4' 8' SCALE: 1/4" = V-0" Chemical Storage Tank Concrete Pad & Roof Structure Evoq ua Water Technologies South Windsor, Connecticut 0 19/26/2022 1 ISSUED FOR CONSTRUCTION MARK DATE DESCRIPTION PROJECT NO: E5012-001 DATE: 11/13/2018 FILE: E5012-001-S-101.dwg DRAWN BY: D.BISHOP CHECKED: TG APPROVED: CSF STRUCTURAL FOUNDATION AND ROOF PLANS SCALE: AS NOTED S-101 SHEET 6 OF 9 Tighe&Bond Engineers I Environmental Specialists a 0 m m E to U) 0 0 N W N 1 O O N N co N \a 0O to '0 LO v 41t 0 �a C a Y C m 0 n 0 b z 21 TOP OF STEEL EL, 91.00' TOP OF WALL EL. 76.50 EXISTING BUILDING /o- o / /o , FOR TYPICAL BRACING CONNECTION AT COLUMN TO BASE PLATE CONN., SEE DETAIL 1 S-301 16'-6" uw I II N 9,000 GAL STORAGE TANK I I I I I I FRP CROSSOVER ACCESS LADDER I L- - - - - - - - - - - - - - - - - - CONSTRUCTION JOINT BASE SLAB AND WALL N L_ FOR K-BRACING CONNECTION AT BEAM, SEE DETAIL 3 S-301 13,000 GAL STORAGE TANK I FRP CROSSOVER ACCESS LADDERS NORTH WALL ELEVATION 1/4" = V-0" 18'-2" TOP OF WALL EL. 79.50 - - - - - - - - - - - - - - - - -- - - TOP OF STEEL EL. 91.75 TOP OF STEEL EL. 91.00' N CONTROL JOINT (WALL ONLY) ---------------------1-- EAST WALL ELEVATION 1/4" = V-0" TOP OF WALL EL. 76.50 TOP OF STEEL EL. 91.00' N TOP OF WALL EL. 79.50 FOR TYPICAL BRACING CONNECTION AT BEAM TO COLUMN CONN., SEE DETAIL 2 IS-3011 TOP OF WALL EL. 79.50 18'- 2" W10 I k6ks/Z6 ���6� I I I I I I / I I I 13,000 GAL STORAGE TANK I I CONTROL JOINT (WALL ONLY) L--------------------- WEST WALL ELEVATION 1/4" = V-0" 18'-6" W8 13,000 GAL STORAGE TANK 16'-6" TOP OF STEEL EL. 91.75' W8 I I I I I i I I I I I I 9,000 GAL STORAGE TANK I I I I I I CONSTRUCTION JOINT BASE SLAB AND WALL L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SOUTH WALL ELEVATION 1/4" = 1'-0" TOP OF WALL EL. 76.50 �.�` pF �C�O N�IV M� Chemical / FOR TYPICAL BRACING Storage Tank CONNECTION AT BEAM TO Concrete Pad & COLUMN CONIC, SEE DETAIL 2 S-301 Roof Structure ),TOP OF STEEL EL. 91.75' Evoqua Water Technologies o, EXISTING / BUILDING j� South Windsor, �j. Connecticut FOR TYPICAL BRACING CONNECTION AT COLUMN TO BASE PLATE CONN., SEE DETAIL 1 S-301 of o� o/ of /e 0 9/26/2022 ISSUED FOR CONSTRUCTION NOTES: MARK DATE DESCRIPTION �e 1. CONTRACTOR TO PROVIDE TEMPORARY LATERAL SUPPORT PROJECT NO: E5012-001 FOR ROOF STRUCTURE UNTIL PERMANENT BRACING IS DATE: 11/13/2018 INSTALLED. FILE: E5012-001-S-201.dwg DRAWN BY: D.BISHOP 2. PERMANENT BRACING TO BE HELD LOOSE UNTIL STRUCTURE CHECKED: TG IS PLUMB. APPROVED: CSF STRUCTURAL WALL ELEVATIONS SCALE: AS NOTED 0 2' 4' 11- 't 8' SCALE. 1/4 -1'- 0 � - � o SHEET 7 OF 9 a 0 s m T m m O O co N N 00 N N � a 71 U) TITO fu (A� o 10 3 a 6 0 n z C a)l 2) COL Ail 'qII ELEV. VAR SEE PLAN (3) #4 TIES ADDITIONAL (4) #6 VERT (TYP.) #4 TIES @ 12" O.C. (TYP.) I (4) #6 DOWELS (TYP.) I FOR SIDEWALK SEE PLAN AND TYPICAL SECTION ON DWG 6" I C-103 Q 4 O.� o SEE ROOF FRAMING PLAN FOR COLUMN SIZE, ORIENTATION AND BASE PLATE ANCHOR BOLT REQUIREMENTS. 1 1/2" SHIM AND GROUT WALL REINFORCING TO BE CONTINUOUS THROUGH COLUMN PIERS. (NOT SHOWN FOR CLARITY) CHEMICAL RESISTANT WATERSTOP AND INVERTED KEY TO BE CONTINUOUS THROUGH PIER FOR FLOOR TOPPING ELEVATIONS AND SLOPE SEE FLOOR PLANS #6@12" O.C., E.W., TOP & BOT. TOP OF BASE SLAB AT EL. 72.50 0 d -1 3'-0" 2" RIGID INSULATION 6" NON -FROST SUSCEPTIBLE FILL TYPICAL PIER REINFORCEMENT (6 PLACES) SECTION A 3/4" = 1'-0" S-101 COL 911 ill OF WALL I ELEV. VARIES, 5" 5" SEE PLAN a #6 @ 12" E.W., E.F. <I A #6 DOWELS @12"O.C.� (TYP.) FOR SIDEWALK SEE PLAN AND TYPICAL SECTION ON DWG C-103 �11 o�Q O C �`rJC COL TOP OF WALL 5" 5" EL. 79.50 a #6 @ 12" O.C., E.W., E.F. —� CHEMICAL RESISTANT ` WATERSTOP AND INVERTED #6 DOWELS KEY TO BE CONTINUOUS . . @ 12" O.C. FOR FLOOR TOPPING (TYP.) ELEVATIONS AND SLOPE SEE FLOOR PLANS • • #6@12" O.C., E.W., TOP & BOT. TOP OF BASE SLAB • • AT EL. 72.50 a � a Q _I Q 2" RIGID INSULATION 6 NON -FROST SUSCEPTIBLE FILL TYPICAL CENTER WALL REINFORCEMENT SECTION C 3/4" = 1'-011 �01 1'-6" SQ. HDPE SUMP BOX WITH 1 Z" FRP GRATING COVER #6@12" O.C. EW, FLOOR TOPPING TOP & BOT. SLOPE SLOPE 1/8— '/�FT� 1 8"/FT -------------------- 1I 2" RIGID INSULATION 6" NON -FROST SUSCEPTIBLE FILL CHEMICAL RESISTANT WATERSTOP AND INVERTED KEY TO BE CONTINUOUS FOR FLOOR TOPPING ELEVATIONS AND SLOPE SEE FLOOR PLANS #6@12" O.C., E.W., TOP & BOT. TOP OF BASE SLAB FOR WALL REINFORCING AT EL. 72.50 SEE SECTIONS "BIT AND TIC" THIS SHEET FOR SIDEWALK • o SEE PLAN AND • �• ;�, TYPICAL SECTION _ 4, ON DWG C-103 —\ a 3'-0" 2" RIGID INSULATION 6" NON -FROST SUSCEPTIBLE FILL TYPICAL PERIMETER WALL REINFORCEMENT SECTION B 3/4" = 1'-0" S-101 rrG�,j �c�G�cop� �1 2 SECTION 1/2" = 1'-0" �01 1011 COORDINATE PLACEMENT WITH SUMP BOX MANUF 1'-6" SQ. HDPE SUMP BOX WITH FRP GRATING COVER AND 1 1/2" • GRATING SUPPORT LIP #6@12" O.C. E.W., TOP & BOT. �I FLOOR TOPPING SLOPE 1 8'�/FT L 1 2" RIGID INSULATION I 11 1 it 6" NON -FROST 1 -6 1 -0 SUSCEPTIBLE FILL_/ SECTION rE 1/2" = V-0" 5-101 L < i ri 31-011 11-C • • • • l TYP 3/8" G (TYP.) W12 COLUMN, SEE PLAN FOR ORIENTATION 1/2" BASE PLAT (TYPE 1) 1 1/2" GROUT - 3/8" GU: BRACING DETAIL AT COLUMN BASE PLATE DETAIL 1 NO SCALE S-201 %A,0 DCAAA A. A-325 :D BOLTS BRACING, SEE AN FOR SIZE 3USSET PLATE W12 COLUMN COLUMN /\-LJI\/-1 \..lIVV, JLL rLI-lIV FOR SIZE BRACING DETAIL AT COLUMN /BEAM CONNECTION DETAIL 2 NO SCALE S-201 W8 BEAM (TYP.) PLAN FOR SIZE —J (TYP.) K-BRACING DETAIL AT CENTER OF ROOF BEAM DETAIL 3 NO SCALE S-201 Tighe&Bond Engineers Environmental Specialists `,`,l,ulnnuuF,, p4 CONNF FRF,�;c� l�,G ilk FIII iII\l\ Chemical Storage Tank Concrete Pad & Roof Structure Evoqua Water Technologies South Windsor, Connecticut 0 9/26/2022 ISSUED FOR CONSTRUCTION MARK DATE DESCRIPTION PROJECT NO: E5012-001 DATE: 11/13/2018 FILE: E5012-001-5-301.dwg DRAWN BY: D.BISHOP CHECKED: TG APPROVED: CSF STRUCTURAL SECTIONS AND DETAILS SHEET 1 OF 2 SCALE: AS NOTED S-301 SHEET 8 OF 9 Tighe&Bond Engineers i Environmental Specialists a 0 m 'm m E 0 n n L 1J 0 n 911 911 2 1/8 SQ TUBE SPLICE CROSSOVER RAIL LADDER CONSTRUCTION LENGTH (TYP) SHALL BE WITH FIBERGLASS (SEE TABLE) MATERIALS UNLESS NOTED OTHERWISE -r - - - 1 (D w _ - _I �/> w ZONTAL BARS`.6,' ww ARD HOOK 2 1/8" SQ TUBE CROSSOVER �G 0 RAIL ROUTED, BONDED, & RIVETED TO 1s" SQ TUBE FORWALL AND PIER LADDER RAIL (TYP) REINFORCING SEE APPROPRIATE / SECTIONS ON DWG S-301 1 1/2" DEEP WITH 1 1/2" 1 3/4" SQ TUBE LADDER LAP OUTSIDE BARS OR PROVIDE SQUARE MESH GRATING 1 CORNER BARS AS SHOWN mac PLAN OF HORIZONTAL REINFORCING AT CORNER PILASTERS 3/8"Ox3" LONG NO SCALE m�� mmmm Hx Hd SS BOLT ASSY Omm� ,Om���DOmOi� O��m�� , m�mmmmOm (TYP OF 4) mm� �mmm omm� �mm000 ` 3"x3"x3/8" SS ANGLE (TYP) COL. 1/2"0 HILTI KWIK BOLT 3 SS EXPANSION ANCHOR WITH ! MIN. 3 1/2" EMBEDMENT (TYP) CONSTRUCTION 3"x3"x3/8" SS ANGLE BOLTED MAXIMUM ANCHOR SPACING JOINT IN BASE TO INSIDE OF 1 3/4" SQ 4'-0" OC W/ MIN. TOP AND SLAB AND WALLS TUBE LADDER RAIL (TYP) I II FLOOR ANCHORS 911 9 3/8"0 x3" LONG SS HEX (TYP) Tj BOLT ASSEMBLY Y / 1 3/4" SQ TUBE LADDER ANCHOR TO FLOOR USING / \ L4x4x3/8 x 0'-2 3/4" SS CLIPS 1 WITH 1/2" DIA. SS ANCHORS. / SHIM AS REQUIRED. (TYP) w - U z �7 w o U 2 0 Uj 0 w � o 0 w � = w z > 0 M U) 0 0 1 j� U 0 O 0 Q a = z w g= m w w CROSSOVER LADDER ISOMETRIC VIEW NO SCALE 21-011_I LADDER CONSTRUCTION SHALL BE WITH FIBERGLASS MATERIALS UNLESS NOTED OTHERWISE 7" 1 ' 1011 2 1/8" SQ TUBE CROSSOVER RAILS 1 3/4" SQ TUBE LADDERS PROVIDE 2" CLEAR (MIN) OVER CONTAINMENT CURB 1 FASTEN CLIP ANGLES TO CONC CONTAINMENT CURB USING 1/2"0 SS EXP ANCHORS WITH 3 1/2" MIN. EMBEDMENT (TYP) NOTE: FLIP ATTACHMENT CLIP ON OPPOSITE SIDES SO THAT EXP ANCHORS ARE NOT IN CONFLICT 711 ANCHOR TO FLOOR USING L4x4x3/8 x 0'-2 3/4" CLIPS WITH 1/2" DIA. SS ANCHORS. SHIMrAS REQUIRED. (TYP) NOTE: TOPPING SLAB IS PITCHED TO FLOOR DRAINS OR SUMPS. SHIM LADDER LEGS AS REQUIRED FOR LEVEL RUNG AND PLATFORM INSTALLATION. CROSSOVER LADDER CROSS SECTION NO SCALE HIGH CONTAINMENT WALL FOR WALL AND PIER REINFORCING SEE APPROPRIATE CHEMICAL SECTIONS ON DWG S-301 STANDARD RESISTANT HOOK (TYP) WATERSTOP REQ'D L AT ALL JOINTS Al - 7 CONTINUOUS L �L KEYWAY LOW CONTAINMENT w = � WALL m j C~7 MATCH HORIZONTAL REINFORCING (n w ww ° O ! OF INTERSECTING WALL HORIZONTAL BARS 5" 5" PLAN OF JOINTS AND HORIZONTAL REINFORCING AT CENTER PILASTERS NO SCALE NOTE: 1. SEE PLANS FOR LOCATION OF CONSTRUCTION AND CONTROL JOINTS CONC. CURB WALL "^ ^ "ICHOR RUNGS PLAN LADDER TUBE ATTACHMENT CLIP 1 1/4" MIN AT 2%2" COPED BEAM FLANGE SEE NOTE 4 inn � 7n L _ 4" (MAX) DOUBLE ANGLES MIN 16" THICK, SIZE AS REQ'D BY AISC STD CONN %4" DIA A325N BOLTS NOMINAL BEAM DEPTH, INCHES ROWS OF BOLTS LENGTH (3) OF ANGLE 12-15 3 8%" 8-10 2 5%2" \/ARTF-1; NOTES: 1. NUMBER OF ROWS IS EQUAL TO NUMBER OF BOLTS TO ENCLOSED WEB. 2. ALL FRAMING CONNECTIONS SHALL CONFORM TO SCHEDULE UNLESS DETAILED OTHERWISE ON FRAMING PLANS. 3. ADD 1 1/2" TO ANGLE LENGTH FOR STAGGERED BOLT CONNECTIONS. 4. 3" DIMENSION TYPICAL EXCEPT AS RECOMMENDED BY AISC FOR LARGER MEMBERS. TYPICAL STEEL BEAM FRAMING CONNECTION NO SCALE COL 6 1/2" i 6 1/2" BRACING GUSSET PLATE, SEE NOTE 1 W12 COLUMN 2 1/16" DIA. BOLT HOLES (TYP.) �0 r0 M N � o BRACING GUSSET PLATE, SEE NOTE 1 4" BASE PLATE, SEE NOTE 1 3" i 3" 1/4 BASE PLATE TYPE 1 DETAIL NO SCALE NOTES: 1. COORDINATE GUSSET PLATE LOCATIONS AND BASE PLATE ORIENTATION WITH COLUMN AND BRACE LOCATIONS. 2. BASE PLATE SIZING TYPICAL FOR COLUMNS A/1, A/2, C/1 AND C/2. COL 11 ' 11 I�6 1/2���6 1/2�� W12 COLUMN N 0 N Q,-1 BRACING GUSSET PLATE, COORDINATE WITH BRACING LOCATIONS 11 -f 11 2 1/16" DIA. BOLT HOLES (TYP.) 3/4" BASE PLATE " 1/4 V BASE PLATE TYPE 2 DETAIL NO SCALE NOTES: 1. BASE PLATE SIZING TYPICAL FOR COLUMNS B/1 AND B/2. 1 1/4" PLATE WASHER AND NUT TOP OF CONCRETE SQ. HE ANCHCI, 4 1/2" THREADED PROJECTION 12" EMBEDMENT DEPTH ANCHOR BOLT DETAIL NO SCALE .``' pF CONNFC CONNF'' AM HgRT/�G', 157 ,�� •. e NS )9/27/022mm,1\I South Windsor, Connecticut 0 9/26/2022 ISSUED FOR CONSTRUCTION MARK DATE DESCRIPTION PROJECT NO: E5012-001 DATE: 11/13/2018 FILE: E5012-001-S-302.dwg DRAWN BY: D.BISHOP CHECKED: TG APPROVED: CSF STRUCTURAL SECTIONS AND DETAILS SHEET 2 OF 2 SCALE: AS NOTED S-302 SHEET 9 OF 9