HomeMy WebLinkAbout250 NUTMEG ROAD SOUTH UNIT N10'-2" SCALE: 1/4"= P-0" RATED >ER FM PARTIAL ROOF PLAN SCALE: 1/4" =1'-O" 1 a ROOF TOP UNIT RD-RT-3 AAON MODEL ... RN-020-0-0-EB09-000... COOLING ONLY NOMINAL COOLING.................................12.3 EER/20 TONS I-VAPORATOR FAN ....... 4415 CFM @1.25" ESP @1039 RPM I VAPORATOR FAN MOTOR.......__...................................................5.0 HP "v... * -'' 'u ' AIVIPACITY (Iv"CA) 2V8-3-6V.......Q8 AMPS ` MAX. OVERCURRENT AMPACITY (MCOP) ..............125 AMPS CONDENSATE CONNECTION SIZE........................................1 " 'SUPPLY AIR OPENING SIZE...................................38.75"x 32" WEIGHT........................................................................2600# 1.ILTERS.........................................................30% & 95%EFF ()PTIONS: i\RIABLE SPEED DRIVE IIOT GAS REHEAT FUME HOOD EXHAUST FAN RD-FHEF-1 GREENHECK VEKTOR H-1 6-14........FUME HOOD EXHAUST FAN FAN RATED...................................................4415CFM @ 1.25 ESP MOTOR BHP=4.76...............MOTOR HP 5.0 NOZZLE SIZE .......... 14", OUTLET VELOCITY=4125 FPM INLETOPENING SIZE...........................................................23.25" WEIGHT.............................................................................. 750# OPTIONS: CURB GRAVITY ISOLATION DAMPER BOILER B-1 LOCHINVAR MODEL WHN-399........ WALL MOUNTED BOILER INPUT CAPACITY...................................................399,000 BTU OUTPUT CAPACITY ................................................. 359,000 BTUH FLOW RATE...................25 GPM.... PRESSURE DROP........1.5 FT ELECTRICAL 1 cVi 1 Pr inrr I iCn u'r1GGi T tLtl� I KII.HL..... I I �V- I I''rIHJt... 17H IVII,H....VVtll�l-I I ............XXX LCSJ PUMP P-1 I B&G MODEL NUMBER................................................NRF-45 FLOW RATE ...............25 GPM......... HEAD ......................... 6 FT ELECTRICAL ..... 115V-1PHASE ............................FLA 2.3 AMPS Pl1MP P-9 B&G MODEL NUMBER................................................PL-45 FLOW RATE ...............21 GPM ......... HEAD ......................... 22 FT ELECTRICAL ..... 1 15V-1 PHASE ............................1 /6 HP PUMP P-3 B&G MODEL NUMBER................................................PLF-45 FLOW RATE ...............17 GPM......... HEAD ......................... 18 FT ELECTRICAL ..... 1 15V-1 PHASE ............................1 /6 HP HEATING COIL HC- 1 TEMPTROL.............................................5WC8-33X35-1 1 A-RH-MA CAPACITY ...............393,122 BTUH......... EAT..O`F .... LAT... 82.1°F FLOW ..... 21.1 GPM 40% PG ... ENT 180'F...... LVG 140° FACE VELOCITY 550.3........... AIR PRESS LOSS 0.26"wg I OTO R COVER BYPASS DAMPER r h INTAKE HOOD W/BIRDSCREEN�, SECTION A SCALE: 1/4"=1'-0" OZZLE ISOLATION DAMPER CURB GC TO FLASH /-ROOF PRESSURE RELIEF VALVE. PIPE DISCHARG TO GLYCOL TANK n CM I CR LOCHINVAR PIPING DIAGRAM SIT 119 PARTIAL_ FLOOR PLAN -PIPING NOT TO SCALE SCALE: 1/4"=F-0" VENT THROUGH SIDEWALL, 10'-0" ABOVE GRADE MINIMUM V � Z CSC . 0 O � v O �zz LU J Q O V W J z [`p V E a MEMO w �S z o .� w i V f W � v HVAC+E+R 165 Stafford Street Springfield, MA. 01104 P.O. Box 4890 Springfield, MA. 01101 phone: 413-737-1196 fax: 413-731-7982 email: mccormick-allum.net OWNERSHIP OF DOCUMENTS DRAWINGS AND SPECIFICATIONS, as instruments of service, are the exclusive property of this company whether the project for which they were prepared is executed and constructed or not. These documents are not to be reproduced in any form or used for any other projects Alterations to these plans is by written authorization and permission from and in agreement with this company. ISSUED FOR PERMIT 1 —23 No. Description Date Revisions Sheet Title: HVAC PLANS & SCHEDULES Project Title: ESCENTIA _• UNIT N, 250 NUTMEG ROAD SOUTH WINDSOR CT. Project No. 07-1310 Issue Date: Drawn By: 1/23/14 RFG Drawing Scale: Checked By: 1 /4"=1'0" RFG M-2