Loading...
HomeMy WebLinkAbout0 METALS TESTINGXW>—N—OZW PROPOSED FUTURE ADDITION 7500 SQUARE FEET USE GROUP F-2 OCCUPANCY 75 PERSONS KEY TO LEGEND 82 DOOR EXIT CAPACITY @ 0.2 " PER PERSON FOR USE GROUPS B, F @ 0.4" PER PERSON FOR USE GROUP H 54' DISTANCE TO EXIT HAZARDOUS MATERIALS: (OCCUR IN EXISTING PLANT ONLY) IN OPEN CONTAINERS AT ACID PIT ACIDS, QUANTITIES OF 300-350 GALLONS, AVERAGE NiTRIC ACID HYDROFLORIC ACID HYDROCHLORIC ACID SULFURIC ACID FERRIC CHLORIDE ACETIC ACID CAUSTICS, IN SIMII.TAR QUANTITIES: ALKALI CLEANERS ELECTRICAL CODE INFORMATION PROPOSED ADDITION WILL CONTAIN NO HAZARDOUS MATERIALS DOCUMENTATION PER NEW 2002 SECTION 500 DEEMED UNNECESSARY PROPOSED 2005 ADDITION 5490 SQUARE FEET USE GROUP F-2 ULTRASONIC METAL INSPECTION (NO CHEMICALS) OCCUPANCY 55 PERSONS is A N PLUMBING FIXTURES PER 1997 INTERNATIONAL PLUMBING CODE W/CONNECTICUT 2000 AMENDMENT USE GROUP B: WC: 1 PER 25 LAV: 1 PER 40 OFFICE: 2 WC's, 2 LAV'S PROVIDED SUFFICIENT FOR 50 PERSONS MAXIMUM OFFICE OCCUPANCY: 23 PERSONS USE GROUP F, H: WC: 1 PER 100 LAV: 1 PER 100 PROVIDED: 6 WC's, 5 LAV's SUFFICIENT FOR 500 PERSONS MAXIMUM PLANT OCCUPANCY: 150 PERSONS i i 1 IN EXISTING BUILDING 11,743 SQUARE FEET 55 GALLON DRUMS OF ACIDS ON PALLET RACKS SPILL CONTAINMENT BELOW 125 GALLUN CLOSED CONTAINER TRICHLORETHYLENE 82 54' t� N 82 USE GROUP H-3 OCCUPANCY 95 PERSONS 92' ACID PIT (55' SHOP AREA MBNTUMCE II SHOP OFFICE EXECUTIVE OMCE 3-HOUR FIRE WALL MAN DOOR: 16 GA UL FRAME TO UNDERSIDE OF ROOF DECK HM DOOR UL LABELED FOP 3 HOURS 3-HOUR MAIN DOOR CLOSER, UL LATCH E 3-HOUR OVERHEAD DOOR W/ AUTO RELEASE/CLOSER FIRE WALL PENETRATION CAULKING TREA"`I°-T 5ystern No. W-L-1UU1 (Formerly System No. 147) F Ratings-1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings-0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient —less than A CFM/sq ft L Rating At 400 F—less than 1 CFM/sq ft SECTION A -A 1. Wall Assembly —The 1, ?, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shalt be constructed of the materials and in the manner described in the individual U300 or 1.1400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs —Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3-5/8 in. wide by 1-3/8 in. deep channels spaced Max 24 in. OC. B. Wallboard, Gypsum"—Nom 112 or 5,18 in. thick, 4 ft. wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 13-1/2 in. 2. Pipe or Conduit—Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe, nom 12 in, diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in. diam (or smaller) Class 50 (or heavier) ductile iron pressure pipe, nom 6 in. diam (or smaller) steel conduit, nom 4 in. diam (or smatter) steel electrical metallic tubing, nom 6 in. diam (or smaller) type 1, or (or heavier) copper tubing or nom 1 in. diam (or smatter) flexible steel conduit. When copper pipe is used, max F Rating of firestop system (Item 3) is 2 h. Steel pipes or conduits larger than norm 4 in. diam may only be used In watts constructed using s?eel channel studs. A max of one pipe or conduit is permitted in the firestop system. Pipe or conduit to be installed near center of stud cavity width and to be rigidly supported on both sides of wall assembly. 3. Fill, Void or Cavity Material` —Caulk —Caulk fill material installed to completely fill annular space between pipe or conduit and gypsum wallboard and with a min 1/4 in. diam bead of caulk applied to perimeter of pipe or conduit at its egress from the wall. Caulk installed symmetrically on both sides of will assembly. The hourly F Rating of the firestop system is dependent upon the hourly hre rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: Max Pipe Annular F T or Conduit Space, Rating, Rating, Oiam, 1n in Hr Hr 1 0 to 3/16 1 or 2 04, 1 or 2 1 1/4 to 1/2 3 or 4 3 or 4 4 0 to 1/4 1 or 2 0 4 0 to 1-1124 1 or 2. 0 6 1/4 to 1/2 3 or 4 0 12 3/16 to 3/8 1 or 2 0 +When copper pipe is used, T Rating is 0 h. 40 to 1-1/2 in. annular space applies only when Type CP-25 WB+ caulk is used and only when the min thickness of the gypsum wallboard is 5/8 in. for 1 hr rated walls and 1-1/4 in. for 2 hr rated watts. Minnesota Mining & Mfg. Co.—CP 25WB+. `Bearing the UL Classification Marking OCCUPANCY 23 PERSONS !. )E GROUP B STEEL CHANNEL JAMB & HEAD TYPICAL FOR OVERHEAD DOOR HEAD SIMILAR W/CHANNEL LINTEL DOOR: OVERHEAD DOOR SERIES 630 3-HOUR RATED TIE INTO SMOKE & FIRE DETECTION SYSTEMS EQUIP WITH FISIBLE LINK EXISTING 8" NORMAL WEIGHT CONCRETE BLOCK WALL PRESUMED TO QUALIFY FOR 1-1/2 HOUR FIRE RATING 1" RIGID INSULATION (EXISTING) 1" FIRECODE GYPSUM BOARD LINER PANELS 2-1/2" C-H 25 GA METAL STUDS @ 24" o.c. 2 LAYERS 5/8" FIRE CODE GYPSUM BOARD SHAFT WALL QUALIFIES FOR 2-HOUR RATING (UL DESIGN U-415, SYSTEM F) TOTAL WALL RATING: 3 HOUR MASONRY AND GYPSUMBOARD CONSTRUCTION MUST RUN FULL HEIGHT TO UNDERSIDE OF ROOF DECK DETAIL OF FIRE SEPARATION WALL 1-1/2" �_0�� = W F- 0 Z J h W 0 0 a oM �2 T 0 r �r z�- JOB NO ; 04.290 , I A7E ; 2-25-05 SCALE ; shown u DRAM BY : DLR I