HomeMy WebLinkAbout99-30P_THE CORN CRIB_BUCKLAND ROADKEY MAP
1 inch equals 200 feet
Adjoining
Owners
within 500 feet
i ;tom• . =4 '.:. _ .'i.-.:*,riiti ''Y'.,` •"�+ ¢„
!'land
r ;� ,"...„ r Luc Road
A I �a`'=,.„'" No. ?
Map 18
Lot 4
Newkirk Associates LLC
?
18
5
Newkirk Associates LLC
t:
I
130
27
9
Krawski, William J.
�1j�c j, s'
?
27
8
Reichle, Earl A. &Barbara H.
151
27
15
Cath. Cem. Assoc. of the Arch. of Htfd.
'� r-.• q , !; .. �...
I I tt•`C�:.
206
27
3
Syme, William M. 8< Rosemary H.
a
207
27
2
Luu, Dinh Hoang & Nguyen Tiang
218
27
4
Cil Realty Inc.
240
27
5
Croteau, Arlene C.
nrw
Im
7
Wrimht Rrndfnrd 1
�a DAinq
Street
No.
379
28
2
Clark Realty Inc.
441-443 28
1
Clark Realty Inc.
... R , ., 't : , i : ry; w�•', .. Rlda Road
No.
?
27
7
Clark Realty Inc.
99
27
6
Wolf, Helmar & Beverly
I hereby declare that, to my knowledge and belief, this map is substantially correct as
noted hereon. This map and survey were prepared in accordance with the standards of a
Class C General Improvement Location First Survey, as defined in the Regulations of
Connecticut Agencies, Sections 20-300b-1 through 20-300b-20 and the "Standards for
Surveys and Maps in the State of Connecticut" as adopted by the Connecticut
Association of Land Surveyors, Inc., on September 26, 1996.
APPLICANT:
LAND SURVEYOR:
NAME OF DEVELOPMENT:
y�eel,
PT.AN PREPARATION DATE:
Richard M. Walton, Connecticut Licensed Land Surveyor No. 16103
ZONING
DATA BLOCK:
Zone GD
REGULA TION
REQUIRED
PROVIDED
Min. Lot Area
5 Acres
12.9 Acres
Min. Lot Frontage
300 feet
261 feet
Min. Lot Depth
N/A
N/A
Max. Stories
2 Stories
1 Story
Max. Height
30 feet
14 feet
Max. Lot Coverage
N/A
N/A
Max. % Impervious Coverage
60 %
> 1 %
Front Yard
65 feet
65 feet
Side Yard
25 feet
110 feet
Rear Yard
25 feet
970 feet
NOTES
This map was compiled from other maps, record research or other sources of
information. It is not to be construed as having been obtained as the result of a field
survey, and is subject to such change as an accurate field survey may disclose.
Drainage Easement at the southwest corner of the property is in favor of the State
of Connecticut for the purpose of drainage and the installation of drainage :structures.
No water or gas is to be connected at this time.
Elevations based upon Buckland Road Reconstruction Plans as filed with the
Town of South Windsor's Engineering Department.
Subject Parcel is located within a Zone C Flood Zone as shown in FIRM Flood
Insurance Rate Map Community -Panel No. 090036 0005B, Effective Date: May 1, 1980,
and does not contain any regulated wetlands.
Site drainage shall utilize the existing Catch Basin. As existing gravel lot shall be
used for parking, there shall be no additional increase in runoff.
Site line distances, as measured from the centerline of the entrance driveway, 10
feet back from the curb line, from a height of 3.5 feet to a height of 3.5 feet are:
To the right (north) = 975+ feet
To the left (south) = 1400+ feet
o a %n W SotdA `l!%/n- -t
1540 SULuVAN AVENUE • SOUTH VANDSOR, CT 06074-2786
+°sa coa" AREA CODE 860/644.2511
FAX 860/6"3781
CERTIFIED MAIL
May 17, 1999
Glenn Reichle
27 Harrington Rd.
East Windsor, CT 06016
Dear Mr. Reichle:
Re: Appl M99-30P, Corn Crib Farm Stand
We are pleased to advise you that the Planning & Zoning Commission voted on May 11,
1999, to approve the above referenced application for a Site Plan of Development.
This approval is for the construction of a farm stand on property located on the easterly
side of Buckland Road, northerly of Manchester, GD zone as shown on plans prepared by
Dubiel & Associates, Job No. 96-06-132, dated 3/31 /99, as revised. This approval is
subject to the following modifications:
1. No building permit will be issued until the final mylars have been filed in the Town
Clerk's office.
2. All plans used in the field by the developer must bear the stamp and authorized
signature of the Town of South Windsor.
Black and white transparent mylars of Sheet I with the above modifications, together with
three blueprint copies of the entire set of plans must be submitted to this Commission
within 30 days to be stamped and signed. The letters of approval of this Commission must
be reproduced on the mylar.
After the mylar has been signed by the Commission, they will be returned to you for filing
in the Office of the Town Clerk. After filing these plans, a copy of the receipt must be
submitted to the Planning Department.
WM/dw
Glen & Randi Reichle
27 Harrington Road
East Windsor, CT 06016
860-627-8549
Richard M. Walton, CT Lic. L.S. No. 16103
Dubiel Associates
34 Connecticut Boulevard
East Hartford, CT 06108
860-528-9081
The Corn Crib
Buckland Road, South Windsor, CT 06074
March 31,1999
Sincerely,
_
Walter Mealy, Vice Chairman
Planning & Zoning Commission
JV
M. 00
y`wyCG- 140, 1614:;3 y
THIS MAP AND ANY DECLARATIONS
THEREON ARE CONSIDERED INVALID
WITHOUT A RAISED SEAL AND ORIGINAL SIGNATURE
N / I
�-
V
Tom^ i
/55
Q
1 PROPOSED 12'x AcRM—STAND
x 6' CANOPY
Q
J
N _
4--WO—P. P RA KING
2 /50`7T
�� ----7T1`—
I 65 'F. Y. Z/
EXIST. GRAVEL
— EXISTIBBII T�PA� D
E. B.
L=22'--------1-1
2I
0
Li CURB
BUCKLAND ROAD
SOUTH WINDSOR
ENGINEERING DEPT.
150
145
/55
TOPOGRAPHY = CLASS T- 2
ST'REETLINC
REVISIONS
GENERAL IMPROVEMENT LOCATION FIRST SURVEY FOR
DATE DESCRIPTION
T12 e Corn Crib
BUCKLAND ROAD
SOUTH WINDSOR, CONNECTICUT
Scale: 1 "=40' March 31,1999
r11 IOIt-1 A0Qnr1ATCC _ r7ACT WART;:nf:Z1 rnNtiFrTlcuT PROJECT No. 99-06-132 SHEET I OF!
r