Loading...
HomeMy WebLinkAbout97-30P_SUBDIVISION PROPERTY OF KEVIN E. WARD_OAKLAND ROADt 89 LEMUEL WALTER O'DELL J W QE F• M/�.� "MAP Fort K1=VttJ E• WABD OAtCL�I�D 1�,OA� Sou i 1-t WIKi1C>S01V_ CT Scat_E /'`=<t-O` 11,lo\/- 1978 WtL_Lt4M J- GA2TLttiGToN 2�.G• Lr�. LLGo.t`L i tLEVIQ 3 Zr SouTi:.1 �ryl►..tDSoTL, GT Ill ID �ir1nVEYn11_ lvtt_ LI 1 L1nLA,"-'nIJ t Co� �jd V QCi E HtLL Qpdp FjF_2(_IU r Gl, C>Co o3� THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-300b-I THRU 20-300b-20 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES-" MINIMUM STANDARDS OR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ENDORSED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. IT IS A PROPERTY / BOUNDARY SURVEY BASED ON A DEPENDENT SURVEY CONFORMING TO HORIZONTAL ACCURACY CLASS A-2 AND INTENDED TO BE USED FORA KA ,F,%%Iitnnrr,,,, ;pF C...... TO MY KNOWLEDGE AND BELIEF THIS MAP IS '�O `�Qi•;v�A,M SUBSTANTIA Y CORRECT AS TED HEREON No. 03b07 NS�O.r�` JOHN L. THO SON REG. LAND SURVEYOR NO.8507 -/ it:+�".�'+ 0MAA,• v SUR -" 96 THOMAS A. DELN I CKI rim ffiAdai ` own : 1540 SULLIVAN AVENUE - SOUTH WINDSOR, CONN. 06074 + AREA CODE 860 / 644.2511 '4SOt CO` � CERTIFIED MAIL June 12,1997 Kevin Ward 325 Oakland Road South Windsor, CT 06074 Dear Mr. Ward: Re: Appl 097. -30P, Ward Special Exception and Subdivision a We are leaMi 16 tltisr 0110s*9 the Planning & Zoning Commission voted on tune 10, 1997 to approve with modtfnj*M~dWt4 t Special Exception to Article 4.6 oftheZoning Regulations to create an interior lot r• d *A*dk tMt W of V Verty located at 325 Oakland Road, AA-30 zone as shown on plans prepared b1 tsa�Mt • t This approval is subject to the following modifications: 1. This approval is for two t�,J lots, numbered 1 and 2. 2. Drainage and construction for this subdivision is subject to 7r approval of the Town Enganeer. 3. All lots shall be served by the Town of South Windsor sanitary sewer system and are subject to the approval of the Water Pollution Control Authority. 4. W4 l E To t1J t= �c]CLt1l S W cP t3 w E Lt, 5. All plans used in the field by the developer must bear the stamp and authorized siirrairrrc Lif t M Town of South Windsor. 6. All easements for conservation purposes, drainage or utilities, that may be required in connection with the approval of this subdivision, must be submitted on standard Town easement form where appropriate, to this Commission prior to filing the mylars and issuance of building permits. All deeds for open space, public improvements and roadways must be submitted prior to request for Town acceptance; all deeds must be in accordance with the policy for acceptirig deeds and must be approved by the Engineering Department and Town Attorney. 7. Footing drains are required for each house. Prior to the building of any structure on a lot, a topographic map, drawn to a scale of 1" = 40', shall be submitted for each lot in the subdivision, showing proposed. contours, elevations and the location of the footing drains. No building permits will be issued until the proposed contours, floor elevations and location of footing drains have been approved by the Town Engineer. 8. If, for any reason, finished grading and other individual lot site work is not completed, the Town Engineering shall determine the amount of a cash bond to ensure final grading and site work. This cash bond must be submitted prior to issuance of a r+effif.iicate of n.cr--nanrv- 9. Quantity estimates must be submitted to the Town Engineer (one n the form) for the purpose of determining subdivision bonding, and all bonds shall be posted pnry r '*8 the plans. 10. A drainage assessment fee in the amount of S50.00 shall be submit'.. �rrimission. 11. No building permits will be issued twin all modifications have been curr.ptrca with and the final plans have been filed in the Town Clerk's office. 12. Engineering comments dated May 20, 1997 must be addressed to the Town Etrgineer's satisfaction. Black and white transparent mylam of sheet #1 with the above modifications, together with three blueprint copies of the entire set of plans must be submitted to this Commission within 30 days to be stamped and sib ed, The letter of approval of this Commission must be reproduced on the mylars. After the mylars have been signed by the Commission, they will W rwAwned to you for filing in the office of the Town Clerk by September 27, 1997. After filing these plans, a espy -I :be receipt must be submitted to the Planning Department. Very truly yours, PLANNING & ZONING COMMISSION Cz.7.La- I/r� Louise Evans, Secretary A,e~, _.• �� `%run. ayeScut% ` &;-Zd4d 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONK, 06074 8601 AREA CODE 8606a4.2511 ~4fOt Cr••• January 14, 1998 Kevin Ward 325 Oakland Road South Windsor, CT 06074 Dear Mr. Ward: Re: Appl #97-30P, Ward Special Exception and Subdivision We are pleased to advise you that the Planning & t r— tg n s oarate driCommission veways associated ted on January 13, 1998 to approve with modificavons u1c 1-i—• - with the approved subdivision on Oakland Road. The modifications are as follows: 1. This approval is for two drive""" 2. The new driveway is to be kK*W ** r1M pan on the plans approved by the State of Connecticut Department e['CY►• must meet Town Standards. 3. The proposed driveway This serer must be reproduced on the final mylar required with the original approval of June 10, 1997. Very truly yours, PLANNING & ZONING COMMISSION a)l.1 n, Caa ,t.o/,o-- Frank A. Castro, Chairman tl1lI p1- `�f)f<• S�untwutnson.CO lfionn74 1,,,o SULLIVAN AVENl1E /+r -A CODE: n6n 1 f+44 /r.... .,. March 11, 199 Mr. Kevin Ward 325 Oakland Road South Windsor, CI. t1607.1 ILF.; 2-Lot Subdivision 325 Oakland Road S011111 WINDSOR, Cr Dear Mr. Ward: The Sondi \Yindsor Water Pollution Control Authority, at its regular meeting of A1111 3. 1998, gave of Kevin f?. Ward - 325 approval for rind connection pollution the n Control sewerage system for a newly created lot at 325 Oakltnid Road, as more specifically shown on Survey A13P entitled "Subdivision -Property Oakland Road •Route No 30 - South Windsor, Connecticut" prepared by John Thomson, Land Surveyor, dated April 24, 1997, revised 2.17-98, and subject to the following conditions: 1, fechnical allProval of tile 'fown Engineering 'riepai.tnent. 2, Final Authority approval and acceptance of the sanitary sewerage connection will the given one the sewer line has been installed and inspected by the Town staff, and based upon ,Ise written vcrificati»nof the Town staff that said sanitary sewer line was installed in substantial confonnancc wdh the design Plans Previousto sanitary sewer construction. ) roved by the Authority, and meeting all rower regulations and appropriate Technical specifications relating L 0 C AT I 0 N MAP SCALE 111 = 1001 }, Itcvie+v of existing casement to the satisfaction of the Town Attorney Iv oT L -; t_1 e PQopoSE� DQLV>= WAS( oN L0Y 9 A 14 1 o ! !us approval letter must be superimposed on the final approval plans. i"St LONS`[TZUGT�.D ,4�j 7f�OWt-i z0 t�l C A A -'�� dt_1 TI�iS �jrJF3DtvtSJot f � Veryt i►yyonts, Ptzopos�� �- 13 iNA I Q1 Lo i 3 or O oa FT 3jo, vo-i a I+ // --.-- `1'ho nns i IIIII n, Chairman t� I i.1 Lo`r W1 DYk-i / I Water Pollution Control Authority t.,� t �l Lo -r Dep�N = I50` 1 7. 13 cc: hiauhc+v Galligan, Town Manager t tichacl J. Gantick, Director of Public Works / / Jerry lazulla, gown Engineer IJ E 1 j L1 L_plarcia 131111ch, Director of Planning lohn Collins, Chief Building Inspector U B D I V I S I O N �'•�� �AQD 10' >,s ROPERTY OF *0 APPROVED BY THE PLANNING 4 1 E IN E. WARD AND ZONING COMMISSION 325 OAKLAND ROAD ROUTE NO. 30 CHAIRMAN SOUTH WINDSOR, CONNECTICUT y� SCALE III = 40' APRI L 24 1997 RE V. ?- 1 7 DATE SCALE IN FEET A�Ca V_ P. E 40 20 0 40 80 To K E V 11.1 IE , WP-Q.0 Nt5 SuccF�,SoQ.S otZ o�StIts 1,44 PROPOSED p= 90-561-4011 �= 30-541-0311 TURN AROUND R = 960.001 R = 960.00' L = 166.66' L = 65.36' L. C. S 490-55-5311 E L. C. S 56°-50'-4211 E 166.411 C 13 1 65.04' / btu 1F=148.04 /� �. F/LA" V !n ✓ awl /IVOUt1i% _ 0A A N p 4.D 2, r K� / 6------ C. 8 SEWER RD/ NV. FL 138.89 K/ R =1960 26 #30 ���_ 1-47 5 -�-- ROUTE ---- T. F. = 1 46. 2 To-,W, '`— F/ L = 14 2 .9 � 1 • PIPE � `\ �-�. L=30�' _ --� I.PIN — r- — S E T , --- I48.5 y `5 50 �� P4oFRALD 156.00 � I 5Or 54 r' — F0C1. \Q t` O 0 1 56' N / F� KENNETH K. KAISER, JR. - f- 8 IRIS M. KAISER / GAR. PROP. HC3USE r W 1 ROP. r DRIVE 162 0 T F. = 1640''• — ° I \� 0 w 10 j, lI I l O rr' W t_ r 1 4 F\A! FV -i �Tt= C70L •— O ` �— �� 0 1 i62 i / O nT 9A (o 20 (P I , J 0 i --- _ iF) 20 ,_I 20' 6 _mil Z W � 6 '�AREA'30�007� ��`o � --� ` �. 'logo ~ AC R E�j m t 11 E I. PIPE 5 168 j S 580 - 58 - 35 FND. -- 50' I:PIPE I 150,001 58t- 2011 W 5 U H W M Q N J Uj S O w U Rik, U Q 2 f I. PIN N 58 154.891 TO 0 31°_01'- 4011E SET / 25.48' �`- lSi N 180 W I n 1'n . I. PI PE FND, 2.10 N M K) N WELL _ LOT 9 _ AREA = 201,296 SO, FT. _ 4.621 ACRES 50, �— 228 ------- — r I,PIPE 352,22 FND. N 530 - 201 06tt W I 30 N/F LOTS H. PETERSON r4�1 I.PIPE FND. F/L 1.4o = ,I�i ,O 4EwIa72-X 1-38.12A Fo LI t,_1 ATI 0 Q / P, Pt? U - D�Alt�l 180 l� L c:i = I o01 �o ��L I-iou�i E = r fir, • p 147, o — 190 10 N/F t'J MORRIS M. 8t GLADYS LANIER -A 1 t9 200 00 N 210 20 2 228 1 ,