Loading...
HomeMy WebLinkAbout05-47P_HORSE ARENA_MAIN STREETHORSE LXARENA FOR PROPERTY C)F DONNA A. LEVACK I I I 61bw MAIN STREET CONNECT LIST OF DRAWINGS COVER SHEET 2 PROPERTY SURVEY 3 LAYOUT, GRADING & UTILITY PLAN 4 CONSTRUCTION DETAILS SITE -- ---- FINAL PLANS - - - - -- -- ---- TOWN OF SOUTH G I D RER CLOSE, JENSEN & MILLER, P.C. AUTHORIZED S REI NDANCE PROPERTIES, LLC 1137 SI LAS DEANE HIGHWAY �.�3���� AND STEVEN B. GOLDBLATT WETHERSFI ELD CONNECTI CUT ®ATE. �; _"� '' 0 . D 1139 MAIN STREET TEL. 860-563-9375 , SOUTH WI NDSOR, CONNECTI CUT Sheet No. j Sb�3TH WINDSGR FAX. 860-721-1802 -PLANNING DEPT. GFNFRAL NOTES 1. ELEVATIONS ARE BASED ON N.G.V.D. DATUM OF 1929. £SrECCE Rl o/ F W. 7,—. ales-G� V&&40t 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 TELEPHONE (860) 644-2511 September 16, 2005 Mr. Steven B. Goldblatt Reindance Properties, LLC 1139 Main Street South Windsor, CT 06074 Re: Appl # 05-47P, Goldblatt Horse Arena Dear Mr. Goldblatt: CERTIFIED MAJL ,)F' Ar`r p-qq FACFAAFNT I U r YH\1�CL U �pyN N/F p� lCCIpS lCCIpS We are please& to advise you that the Planning & Zoning Commission voted on September 13, 2005 to approve with modifications the above referenced application. This approval is for the construction of a 11,900 sq ft horse arena on property located 1120 Main Street, .A.-40 zone as shown on plans prepared by Close, Jensen and Miller P.C., dated July 2005, as revised. This approval is subject to the following modifications: 1. Housing/stabling of horses is restricted to the rear yard of the premises. Use of trailers for stabling horses is not permitted: The accessory buildings used to shelter or feed the horses must be located at least 125 feet from the street, 40 feet from any side or rear property line, and 100 feet from any dwelling located on the adjacent property. Outside feed troughs must also meet these setback requirements. 2. Manure shall not be allowed to accumulate to cause any health hazard, and shall be subject to inspection by the Health Officer. Fly control measures are required. 3. There shall be no outside storage of feed or bedding materials 4. The A-2, T-2 certification niust be added to the layout plan and thatsheet must be filed in the office of the Town Clerk. Black and white transparent mylars of Sheet # 3 with the above modifications, together with three blueprint copies of the entire set of plans must be submitted to this Commission within 30 days to be stamped and signed. The letters of approval of this Commission must be reproduced on the mylars. After the mylars have been signed by the Commission, they will be returned to you for filing in the Office of the Town Clerk. After filing these plans, a copy of the receipt must be submitted to the Planning Department. Sincerely, Timothy H. Wendell, Chairman Planning and Zoning Commission PROPOSED 3-3" DIA. ELECTRIC CONDUITS QFhAnVF F7VIQTINI(, CONSTRUCTION * EXISTING BARN ENCROACHMENT NOTES: 1. THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-30OB-1 THRU 20-30OB-20 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES — "STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC. ON SEPT. 26, 1996. THIS IS A PROPERTY SURVEY BASED ON A DEPENDENT RE —SURVEY CONFORMING TO HORIZONTAL ACCURACY CLASS A-2 AND VERTICAL ACCURACY CLASS T-2 AND IS INTENDED TO DEPICT THE POSITION OF BOUNDARIES WITH RESPECT 'TO LOCATIONS OF ALL BOUNDARY MONUMENTATION; APPARENT IMPROVEMENTS AND FEATURES; RECORD EASEMENTS AND VISIBLE EVIDENCE OF THE USE THEREOF; RECORD AND APPARENT MEANS OF INGRESS AND EGRESS; LINES OF OCCUPATION AND DEED RESTRICTIONS PERTAINING TO THE LOCATION OF BUILDINGS OR OTHER IMPROVEMENTS. 2. THIS SURVEY IS NOT VALID WITHOUT A LIVE SIGNATURE AND EMBOSSED SEAL. TO MY KNOWLEDGE AND BELicIF THIS MAP IS SUBSTANTIALLY CORRECT AS NOTEO HEREON. r BY JOHN H. MILLE"", P.E., L.S. LIC, NO. 4142 kA TyCERy A N/F YOQNc CINDA CF'/IcF k DOCpe MAP REFERENCE: 1. RESURVEY PREPARED FOR' DONNA A. LEVACK, 1116 MAIN STREET, SOUTH WINDSOR, CONNECTICUT, SCALE: 1 "=40', DATED: 12-27-04, LATEST REVISION 3-17-05, SHEET 1 OF 1, BY: RICHARD P. MARTEL, L.S. 12882, DESIGN PROFESSIONALS, INC. 165 SOUTH SATELLITE ROAD, SOUTH WINDSOR, CONN. 2. PROPERTY OF RUSSELL E. & LOUISE W. LEVACK, MAIN STREET, SOUTH WINDSOR, CONN. SCALE: 1"=100', DATED: 11-7-78, BY EMIL W. LUCEK ASSOCIATES. No Date Description Revisions S 6535 �2„ 2 /23/0 CONDITION OF APPROVAL 1 8/4/05 SOUTH WINDSOR STAFF COMMENTS No. Date Description Revisions frrrrrurrr������ H N0. 4142 CE It ''��rnrsrr�rrrrr►r 2. BEARINGS SHOWN ARE BASED ON STATE OF CONNECTICUT GRID COORDINATE SYSTEM. 3. THE UNDERGROUND UTILITIES ON THIS PLAN HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND HAVE BEEN LOCATED IN THE FIELD WHERE POSSIBLE. THE ACTUAL LOCATION OF THESE UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR BY CONTACTING "CALL BEFORE YOU DIG" 1-800-922-4455. 4. ALL PROPOSED UTILITIES LOCATED WITHIN THE DEVELOPMENT LIMITS SHALL BE LOCATED UNDERGROUND. THE HORIZONTAL AND VERTICAL ALIGNMENT OF SUCH UTILITIES SHALL BE DETERMINED BY THE APPROPRIATE UTILITY. 5. ALL UNSUITABLE MATERIAL DISCOVERED DURING CONSTRUCTION SHALL BE REMOVED OR DISPOSED OF IN A SUITABLE MANNER. SAID MATERIAL SHALL INCLUDE TREES, BRUSH, ORGANIC MATERIAL, ETC. 6. SOLID WASTE DISPOSAL SHALL BE DUMPSTER PICK UP. 7. ALL WATER MAINS SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS AND CONSTRUCTION METHODS OF THE METROPOLITAN DISTRICT COMMISSION. 1 I , it IF_1 PROPERTY IS LOCATED IN ZONE .A-40 MINIMUM LOT SIZE 40,000 S.F. MINIMUM LOT WIDTH 150' MINIMUM LOT DEPTH 200' MINIMUM FRONT YARD 50' MINIMUM REAR YARD 50' MINIMUM SIDE YARD 20' MAXIMUM STORIES 2 1 /2 MAXIMUM HEIGHT 30, MAXIMUM % LOT COVERAGE 10% wNTINv/ I/F Sc�Ty WIND CARE OF SOR, /NC PROPOSED 195,375 S.F. 278.04' 756' 52' 530.25' 42' 1 27.755' 6.23% Consulting Engineers, Land Planners & Surveyors 1137 Silas Deane Highway, Wethersfield, Conn. 06109, Tel. (860)563-9375 LAYOUT, GRADING & UTILITY PLAN HORSE ARENA FOR STEVEN AND PATRICIA GOLDBLATT REINDANCE PROPERTIES, LLC PROPERTY OF DONNA A. LEVACK 1116 MAIN STREET CONNECTICUT SOUTH WINDSOR, Compiled P.C. Check Designed D. (2 Drawn ,j>, o Checked 06 Scale 1 "= 40' Date JULY 2005 z Q Sheet Of 0- 3 4 C� Job No. Q File No. E `� FINISH PIPE O.D.+24" OR 3'0"MIN GRADE— �• • \ I TRENCH PAY LIMIT u Q _w � z O U m F - U IJ- 0 w ri n O o I-- z _z ME :�E O N SCREENED SAND BLUE WARNING TAPE BACKFILL PLACED AND COMPACTED IN 12" LAYERS COMPLETE ENVELOPE OF FILTER FABRIC WITH 12" OVERLAP REQUIRED WHEN CRUSHED STONE IS USED AS BEDDING MATERIAL. FILTER FABRIC REQUIRED IN ROCK AS DIRECTED BY ENGINEER - BEDDING MATERIAL SHALL BE BANK GRAVEL (DOT GRADING A), WELL GRADED SAND OR 3/8" TO 3/4" CRUSHED STONE*, PLACED AND COMPACTED IN 6" LAYERS. GRAVEL FILL AS DIRECTED BY ENGINEER WHEN UNSUITABLE MATERIAL IS ENCOUNTERED *CRUSHED STONE SHALL ONLY BE USED IN HIGH GROUNDWATER CONDITIONS AS DIRECTED BY THE ENGINEER OR FINISHED GRADE WARNING TAPE SUITABLE BACKFILL MATERIAL "HO-PAC" OR TAMPED AS PER SPECIFICATIONS AND AS ORDERED BY THE ENGINEER 12" 12" 3" COUNDUIT TYP. DISTANCE BETWEEN CONDUITS REQUIRED AS PER UTILITY CO. ELECTRICAL TRENCH DETAIL i OR p�j Rp Pp _ 0 00 0 'qS / o0 00 0o Sy o moo ow O� 00 000 000 0 0$ oo � 4" MIN. THICK ON oo FILTER FABRIC \ FILTER FABRIC CT DOT 2" CRUSHED STONE PAD WIDTH AS SHOWN ON PLANS CONSTRUCTION ENTRANCE 4" COMPACT GRAVEL 10'-0" O O �O O 000 00 O 00 � O.p DO O pb0 O O O O�° °O�°0000 O ° O ° O O° ° O° 0 0 000 0 00 00 0°°° 000 00000 00° 0pO pO pO °pp00 000 DO 0 000 00p0 0° 00000 0 000 0° opOoo o° \o 0 00 0 0 6" SUBBASE GRAVEL DRIVE DETAIL WOOD OR IVIE I AL PUS I S WOOD OR EROSION CONTROL METAL POSTS FILTER FABRIC. �p ATTACH TO POST AND BURY IN TRENCH � Q BACKFILL z ( Q BACKFILL DIRECTION OF FLOW EROSION CONTROL FILTER FABRIC 1 8 4 05 SOUTH WINDSOR STAFF COMMENTS No. Date Description Revisions SECTION D-D SILT FENCE ,AL.