HomeMy WebLinkAbout04-67P_PARKS IN-LAW,PARKS RESIDENCE_AUTUMN ROADGENERAL NOTES AND 6FECIFICATION8
1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
2. LABELLED DIMENSIONS CONTROL - DO NOT SCALE DRAWINGS, SUBCONTRACTORS TO
VERIFY ALL DIMENSIONS IN FIELD.
3, TYPICAL FOUNDATION MATERIALS-
- CONCRETE: 3000 PSI FOR GARAGE FLOOR SLABS, 2500 PSI ELSEWHERE.
- CONCRETE FOOTING: DEPTH TO BE 8" (MIN) FOR 8" CONCRETE THICK WALLS;
10" (MIN) FOR 10" THICK CONCRETE WALLS.
- SUB -BASE FOR CONCRETE SLAB FLOORS TO BE 6" COMPACTED GRAVEL
WITH I" COMPACTED SAND COVERING BETWEEN CONCRETE AND GRAVEL.
- ALL CONCRETE EXTERIOR STEPS TO BE SUPPORTED ON CONCRETE HAUNCHES
POURED WITH FOUNDATION WALLS,
4. TYPICAL FRAMING MATERIALS:
- FRAMING: FASTENED TO FOUNDATIONS WITH 1/2" DIAMETER ANCHOR BOLTS
Q 6'- 0" OC AND V- 0" ( MAX. ) FROM CORNERS.
- FRAMING LUMBER TO BE HEM -FIR *2 OR S-P-F 01 OR BETTER; STUDS TO BE
HEM -FIR OR S-P-F STUD GRADE. ALL FRAMING IN CONTACT WITH CONCRETE TO BE
PRESSURE TREATED,
- DOUBLE FLOOR JOISTS UNDER ALL PARTITIONS,
- ALL HEADER SIZES IN EXTERIOR WALLS TO BE 2 - 2 x 8 HEM FIR 02 UNLESS OTHER-
WISE NOTED ON PLANS, HEADERS ABOVE GARAGE DOOR OPENINGS TO BE
2 - 2 x 10 HEM -FIR 02 UNLESS OTHERWISE NOTED ON PLANS.
ALL HEADERS IN INTERIOR BEARING PARTITIONS TO BE 2 - 2 x 8 HEM -FIR 02 UNLESS
OTHERWISE NOTED ON PLANS.
- ALL FLASHINGS IN CONTACT WITH PRESSURE TREATED LUMBER TO BE COPPER OR
HOT DIPPED GALVANIZED METAL.
j 5. INTERIOR MATERIALS:
- EXTERIOR WALLS TO HAVE 4 MIL (MIN) POLY VAPOR RETARDER INSTALLED ON
INSIDE ( WARM SIDE ) OF WALL,
- INSTALL INSULATION BLOCKERS AT EAVES WHERE REQUIRED. INSTALL PRE -FORMED
vENT CHUTES IN VAULTED CEILING AREAS WHERE REQUIRED.
- GARAGE WALLS AND CEILINGS ADJACENT TO LIVING AREAS TO HAVE 5/8" TYPE X
FIRECODE DRYWALL.
C6, TYPICAL DESIGN LOADS:
- ALL ROOMS EXCEPT SLEEPING ROOMS < ATTICS: 40 PSF LL + 10 PSF DL
- SLEEPING ROOMS AND ATTICS WITH STORAGE: 30 PSF LL + 10 PSF DL
- ATTIC SPACE WITH STORAGE NOT POSSIBLE: 5 PSF LL + 10 PSF DL
- ROOF: 35 PSF LL + 10 PSF DL
34'-5"
9'-O ° 20'-511 51-0 1I
1'-011
DROP TOW 6"
FOR PC FLOOR
r ---- =-------± -- ;--.-__ ; — -----; ---_ - -- =- :---------------
; -
1 '-----------------------------------------------------, v 1
I 1 1
r----------------- v------------------
----------------------------------, i .c CUT OUT TOW 6" i 'v
' ' I I FOR PC FLOOR __
1 C I N ---' , 1-------' C `------------- '+
' - L---- `------- ---------------------------------CO- ----
1 �
� v � v v
p ago _ _a p ago �.,-e p a� ' ° D °'���
' L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---------------- -- ----------, , 1
l 0 1 1 4 1
I I
1 I I p 1 1
I31-511 ( I 51-/ II i .L, 11
1
1 n I I 1
1 l I 1
• ;' a; 1 I I � t 1
' I I XLU
; 4
1 I I I } I O I
I I O
I p 1
24" x 24" x 12" 13 1 1
I - I
PC FOOTINGS
-------------------
1 1
I v 1 1 1 I 1
I I I I
I I
I I
I I
r- ---------------� 1
r-------------�
-----------------------------
I a pQ. Q 7 D I N 1 4 i , r-- '-
1 - ' r, 1 1 &- 11
`---------------- m '
I - �
If REMOVE EXIST G WALL II
1 O _ 'B-6 I-6
22 4'
34'-p"
FOUNDATION PLAN
5CALE--1/4 =I O
11
121-011
34'-5"
---------------------1q
I I
I I
l I
t t
I 1
RELOCATE EXIST'Ga WINDOW
8x8DECK
C ABOVE) 41-011
1 I
I I
' INSULATE UNDER STAIRS
1 I
I I
I
I
I -
, 1 I 11 I I I I 1 m
- — - - - - - I
--'--------------------- U 1 R O '
I FLOOR ABOVE I I I I I I I I I X
1 1 I I 1 1 I I I I o I -
, 1 I I I 1 I 1 I 1 M m
O I I I I I I I 1 1 1 1
I I I I I I I I 1
X b�-au
1 , I
30�o8 OPENING O I I 3 �
1 U nu nl I I O
4 O fill III II D 4
_ fill III
W iii �9 I I
1 @ fill 6) fit
r
� iiii
1 u X O
i 0 2 x 10 F,J, olro OC iiii iii I I w
t i X iiii - --iii I I I- LU
EXIS I I�}�I�
RE81DEl `lCE
lU
I 61 IIII � I11 �
X --iii Z I I }
- - - fin ul F I I O
- - - % iiiiuj
m iii I I
iiiitill
X
U �• iiii
O � un nl
� II
A m iiii i --iii-- 2 x to C,J, 'al(o" OC
(a 1 lit
4 m nu 2 x 10 F,J, -al(o" OC i i r' ------------
nl I I
p IIII 111 , I I I
--- —I`J - --------------'ill_-----------111—L - ---- -'—
I111 111 ,
1
X i---------------------------i---------
in r------------ ------ � III , I 1
OI I IIII , I 111
I 1 till
I t fin
1 1 till ,
till , g x I OH DOO I(NEW)
- I I IIII I 1
IIII I I
"" , , I
9 x -1 OH DOOR (EXIST'G) ; till; 9 x -1 OH DOOR (EXIST'G)
_ J
REMOVE EXIST'G WALL
1'-3" g'_O11 11-p11 11-311 0
91-�1 11-g1�
J I
22'-S" 121-011
6'-6° 1_ 34'-13"
FIRST FLOOR PLAN
1/411 = 11 - 011
iDEPT.
O
0
N
N
NOTE:
ADJUST WALL HEIGHTS ON FIRST FLOOR SO THAT SECOND
FLOOR SURFACES ARE FLUSH BETWEEN EXIST'G AND NEW,
rz
N
NO
t9
O
e�
M �
Ifrr
n
U
VJ T+
N
w
m id
W
p
Z
> O
I
0.U(L
w'`
2
0
1
L�
T
REVISIONS:
DATE: —
01/28/2004
DRAWN BY:
NDF
Lu
z
Lu
ul
z
J
O
A
0
.4
�
(nL
>
W_
3
0
U
LL,
Lu
O_
-v
�
zLu
c>D
a
N
Es
ch
6
A
Id
Q
ESCALE:
1/411=11=011
DRAWING NO:
A m
UJIN01 0W
SCHEOUJ_E
= n
/III v Ll)
1 MANHIP
IP
niY
i��Md ICE
C1 A
7.
FROOF PLAN
V
tx
0
ui
z
w
to
REVISIONS:
.,A f5-1
DATE:
0`1/20/2004
DRAWN i3Y:
I ID F
11-
nO
OL
1�
V
I�
>
�I
Q
ip
O
SCALE:
1/4II 11 o OII
DRAWINS NO:
A�2
JLJ
ILJ
rpc -
lvc�-, --
C, i-ll
L� C;,, C� C-� -jQ,
Rc-
DSE VENT
12
�6
I I I I I 1
I I I I I I
l I I I
I
I I 1 i 1 I
1 I I ( I I
I I I 1 I I
I I 1 1 I 1
1 1
r r.. r__r_s---_-rrrr r r r r r r r r r_ r r_ r r r r.._ r_.. r r r rA.,
II I r A r r r_________ r__ r__ r_ r____ r ._ r__ r_ r r _. _ r r_ r r_ r r r r r r r r r r r_ r r .. r r I I
I I I I I I
I I I r r r r r__ r_ r r r r r___ r r r r .. r r r r .. __ r r J
L r r .�. r r r r r r��� r r r r r r r r r r r r r r r r� .. r r r r r r r r r r r r r r� .� � r r r r r r r r r r r r r r r r r r r r �1 .� rrrr r
I I I i
I I I 1
1 1 1 i
I I I I
I I I I
I i i 1
I I I I
I I I I
- r r r r -- - - - - r r r r--- r r r r r r r r r r---- r r r r-- ---- -- r r r r- ---- -- --- r r r r r r r r r r r r r r r r r r r r r r r r r r r r r- .. .. r r r r r r r r r r r r r r r r r r r r r r r- - r r- - r r r r r r r ..1 -�- r r r r r r r r r r- r- - .�
I I I I
L r r r r r A r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r r- r r r .. ---- r r r r r r r r r r r r r r r r .. - r r r r r r r r r r r r �- r r r r r r r r r r r r r r .- r
FRONT ELEVAT
ION
SCALE: 1/4" = 11 - Ott
I I I I
I I I I
I I I I
1 I 1 1
I 1 I I
I I I 1
1 I I 1
1 1 I I
I I I I
� A r r r r •' A r r r- r r r r r r r r r r r r r r r r r r r r r r r- r r r r- r r r r r r r r r r r r r r r- r r r r r r r r r r r r r r r r rl - - _ r r r r r r r r r r A-
1 1 1 1
1 i 1 I
Lrrrr rrrrr rrr.._rrr_r-_rrrrr-.....-....__rrrrrrrrrrrr -rrrr.rrrrrrrrrrrrrrrrrrrr.r rrrrr.'rr_rrrJ
I i 1
I I I
I I I
I I I
I I
I 1 I
I I I
i I I
I 1
-J.rrrr.rirrrrrrrr rrrrrrrrrrrrr-rrrrrrrr- rrrr.. --rrrrrrrr-r- -r-rrrr-rr- - - - - -rrrA.�
I I I
----------------------------------------------------------------------
I I
RICxHT SIDE ELEVATION.
�70
u
D
NO
M
O
Qm
00 a
Mn
m�
OM
N
U
x ~ •-
W Z
>o
a U a
U
`D�CO
V
p
cn
0-
tu
V��
IL
O
IJ-
z
w
Q
REVISIONS:
DATE:
Oi/2a/2®®4
DRAWN BY:*
Df=l
cn
o
lu
UJ
p
�
r
U
C�
0
CD
l�3
Q
m
O
SGAI_E:
11411 _ 11 = ®II
SCALE: 1/4" = V _ 011
DRAWING NO:
A�3
ENGINEERED GIRDER TRUSS SUPPORTS
TRUSSES WITH METAL HANGERS
NEW IBATH
SISTER EXIST'G CJ'S
WITH NEW 2 x 10 F,J,
EXISTIG LAV
I
D`
•4
as
EXIST'G 5 ASEMENT
• Qt
0�
2
6�
ROOF TfPU55ES �b 24" OG
BRACE ACCORDING TO
MANUF'R IN5TRUtTIONS
12
\�6
R-38 INSULATION
E5/5" DRYWALL ON CEILING
NEW fBEDROOM
2 x 10 F,J, a16" OC
rR-19 INSULATION
D/S" FC DRYWALL ON ` 3-1 3/4" X la" LVL BEAM (1,9E )
:ALL GARAGE SURFACES
EX15T'G GAIRAGE
24" x 24" x 12"
PC FOOTING
MATCH EXISTING EAVE
DETAILS k DIMENSIONS
-2 x 10 HIP RAFTER
12
2 x 8 R,R, alb" OC
2 x h G,J, alG" OC
1--4/4" X 11 1/0" LVL BEAM (1,9E)
NEW G,4iz,aeGE
1/�" LALLY COLUMN
4" PC FLOOR SLAB
SECTION A —A m BEDROOM / GARAGE
sC<, E 14 . , - a
11
NOTE:
ADJUST WALL HEIGHTS ON FIRST FLOOR SO THAT SECOND
FLOOR SURFACES ARE FLUSH BETWEEN EXIST'G AND NEW,
ADJUST WALL HEIGHTS ON SECOND FLOOR 50 THAT ROOF
TRUSSES ARE FLUSH WITH EXIST'G ROOF SURFACE a REAR
AND SOFFITS AND FACIA5 ARE IN ALIGNMENT,
2 x 10 HIP RAFTER
2 x 8 R,R, wir," OC
5/0" ROOF 5HEATHING
1�ROOF TRUSSES a 24" OC--�, (o
m
12
6
--R-38 INSULATION
" DRYWALL ON CEILING
2 - 2 x 10 HEADEi�
2x6C,J,a1�"OG
® ® At
O
—R-13 INSULATIOk 4 5/5" FC
DRYWALL UNDER STAIRS
3" PG SLAB FLOOR
2 x 4 FRAMING alto" OC
R-13 INSULATION
2 x 10 F,J, 9D 16" OG
R-13 INSULATION
',
I
� 4
p,
i
�o
I .g
•
'V
av
I_____________ 1� ________________ ____
D•�
t - - - - - -.- r r - - - - - - - - - - - - - - - - - - - - - - - - - - - - ` - - - - - - - - - - - - - - - - - - - - - - - - - - - - - r r - v7
V D - - - - - - - - - - - - - - - - -
SECTION B-8 g ENTRY < STAINS
s�ALE: 1,4 , - 011
2 x 4 FRAMING al(o" OG
N0
0
O
W N
N
V 0W
►A � _N U
w � arc
x Z••
�..1 > o
a.. U a
w
2
0
T
Lam'
0
REVISIONS:
DAZE:
01/20/2004
DRAWN eY:
NlDf=l
U-1
nV0
�
7
®
Lu
wwnn
v,
1:
v/
V
Q
O
FE:
1' =0"
DRAWING NO:
i
4