HomeMy WebLinkAbout2017-3-17 - 24 Lewis Drive - Water Potability Test5 Aquatek Labs 3 Research Drive ~Woodbridge,CT 06525 Water Analysis Report TEST lD‘.E031717021 DATE SAMPLED:3/17/2017 TO:TERESA O'CONNOR SAMPLE POINT:KITCHEN NO TREATMENT SAMPLED BY:MIKE CUNNINGHAM PROPERTY LOCATION:24 LEWIS DRIVE -SOUTH WINDSOR ,CT CONCLUSION:Based on the above results,this water was safe for drinking purposes at the time of collection. S P : =Secondary Primary limit, limit. used recommended to judge potability but not required @222 i / ’ ( LOT/"7522,...— r Z!MRL =Minimum Reportable Level *Limit exceeded Michael F.Berman,Ph.D. ND =None Detected CT License #PH-O466,Aquatek Labs Laboratory Director R =Reference Lab Work /:> Page1 of1 for test#E031717021 BACTERIA ABSENT PRESENT LIMITS REF METHOD Coliform (Total)E/D ABSENT P SM 9223 E.Coli (Fecal)12 D ABSENT p SM 9223 Chlorine (Total)E4 D ABSENT SM 4500-Cl G PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL REF METHOE pH 7.0 SU 6.4-10 S 0 SM 4500-H B Turbidity 0.25 NTU 5 —0.10 SM 2130 B Color ,ND CU 15 S 5 SM 2120 B Odor 1 TON 2 S 0 SM 2150 CHEMICALS RESULT UNITS LIMITS MRL REF METHOD Fluoride ND mg/L 4 P 0.3 EPA 300.0 Chloride 35 mg/L 250 P 3 EPA 300.0 Nitrite Nitrogen ND mg/L 1 P 0.1 EPA 300.0 Nitrate Nitrogen 4.8 mg/L 1O P 1 EPA 300.0 Sulfate 14 mg/L 250 S 4 EPA 300.0 Calcium 46 mg/L NONE -0.5 EPA 200.7 Magnesium 3 mg/L NONE -0.5 EPA 200.7 Hardness 126 mg/L 200 S 4 SM 2340 B Sodium 14.9 mg/L 100 S 0.5 EPA 200.7 Copper 0.08 mg/L 1.3 S 0.04 EPA 200.7 Iron ND mg/L 0.3 S 0.04 EPA 200.7 Manganese ND mg/L 0.05 S 0.04 EPA 200.7 RADON WATER SINGLE RESULT UNITS LIMITS MRL REF METHOD Radon Water Single 1401 pCi/L 5000 S 51 SM 7500-RN