Loading...
HomeMy WebLinkAbout1980-7-14 - 1970 John Fitch Boulevard - Septic Applicationi¥ i TOWN OF SOUTH WINDSOR HEALTH DEPARTMENT Application To;permit to Install a new/repair subsurface sewage disposal system To the Health Department Curtain drain required rug:[may huvb 7k;be,i u.)hog/Li bJ K'ufls’fé/(Hg/é: Yes,No l Height of system above ground water W,”,maximum ground water /Y (I ledge t/,impervious soil layer If automatic closing is required,description A PLOT PLAN lNDlCATING LOCATION OF PROPOSED STRUCTURE,WATER SUPPLY,SEPTIC SYSTEM,EM- BANKMENTS,WATERCOURSES,PROPERTY LINES AND ALSO INDICATING EXISTING AND PROPOSED FINISHED GRADES MUST BE SUBMITTED BEFORE THIS PERMIT CAN BE ISSUED. THIS PERMIT IS NOT TRANSFERRABLE FROM PERSON TO PERSON OR FROM PLACE TO PLACE. NO PART OF THE SYSTEM SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE SANITARIAN. SPECIFICATION AND REQUIREMENTS AS STATED IN THIS PERMIT MUST BE MET AND ANY CHANGES MUST BE APPROVED BY THE TOWN SANITARIAN BEFORE FINAL APPROVAL WILL BE GIVEN. THIS PERMIT SHALL NOT BE CONSTRUED AS PERMISSION TO CREATE A NUISANCE CONDITION NOR IS THIS SYSTEM GUARANTEED BY THE HEALTH DEPARTMENT. ygx /V z/V/ Signature of Applicant &License tlumb Permit Received by For Office Use Only Permit issued by Date 7~Ms W i”System installed by Final Inspection Approval DateI Town of SoutNWmdsor Fee Paid;‘Date Permit Number As a subSqrface sewage disposal system installer Iieensed tn,the §tate of Connectlcut iz,;/K7 [u L iv 'w'rt,/<(,r //(’yexu‘iil/371‘grow/[2 2//7/// Name Address Telephone Number,LlcenseNumber hereby apply for a permlt ’t‘o ’construct/repairmm!v 7 \7/’W )U ~- a subsurface sewage disposal and owned by “>154 “U system located at 1’91;OIZ //( Street Address Lot Number Name Address Informatlon to be supplied b plucant Type of dwelling it §Cl e6 .If non-residential,estimated daily flow Informatlon to be supplied b plucant Type of dwelling it §Cl e6 .If non-residential,estimated daily flow Restdential Commerctal Etc Numberofbedrooms 4i Size of lot 5E Ha f Number of fixtures above basement Tubs,Sinks,Toilets,Etct Number of fixtures in basement,ifany Pumped orgravityflow, Type of watersupply m (era/é .If private,type ofwell OM t t t &&t Pt%lic Private Information to be supplied by Health Department: Soil type at various levels slaved);I a aw is (fay Percolation rate .Square feet of effective leaching area required QO La Size of septic tank Type of system T VMVQEW§ Trenches,Drywells,Etct Num er of dry wells,trenches,etc.IV .Distance between individual leaching 95’'75” a 51 r'a 35/ /;‘\.1 S,G 3)L:Q xv)‘S 1‘ I s éIJ \\§'ux 4/:\\*i CK ’mN3.'\S ‘i°§.l i 51 i r a lé‘bo€I cvé Tgbwj§§4 i $5 \"W \K $3 E i Q:,y;§‘a;L‘_\N‘r I f 11 ’ x+1 7.. “-¥\\\:Ky f R\Q\&1 i NOTES SOUTH WINDSOR POLLUTION CONTROL LOCATION gawk g OWNER ’3 (CK/x L O ‘(Vx Ki \HA TYPE OF WORK 415:?M DATE ’?w x’‘jwr EOPERMIT PIPEINSTALLERPg?{gcivxr INSPECTOR ’3 x DRAWN BY f9.A; 7&11111 OF S0ui/L WW 1540 SULLIVAN AVENUE o SOUTH WINDSOR,CONN.06074 AREA CODE 203/644-2511 May 22,1980 Mr.John C.Midlin349GriffinRoad South Windsor,CT 06074 Dear Mr.Midlin: Unfortunately,as determined by Mr.Stead from the firm of Peterson 5: Hoffman,the finished floor elevation of your residential dwelling located on Route 5 in South Windsor is approximately seven feet lower than indicated on yOur plan,which was approved in August of 1979.Because of this,it is impossible to keep the flow line of the leading trenches at the approved elevations utilizing gravity flow and be in compliance with the State Public Health Code. At this point,you may either utilize the same septic system design, with the 'addition of a pumping chamber to raise the effluent to the proper elevation,or try to find an area to relocate your system.The new area may also have to be pumped.In either case,a revised engineered plan must be submitted for approval.If a pump is utilized,manufacturer and model number must be indicated and size of pump chamber must be shown.If a new area is to be used,additional observation pits must be dug in the presence of the Town Sanitarian to find a suitable area. If you have any questions on the aforementioned,please do not hesitate to call me at Town Hall,644-2511,Extension 42. Very truly yours , TOWN OF SOUTH WINDSOR Robert Dept‘ula,R.S. Town Sanitarian RD:bw cc:Inland—Wetlands Commission Donald McLaughlin,Building Inspector CERT IFIED MAIL:#461455 STATE OF CONNECTICUT DEPARTMENT OF HEALTH SER VICES BUREAU OF HEALTH PROMOTION AND DISEASE PREVENTION July 9,1980 Mr.Robert Deptula,R.S. Town Hall South Windsor,CT O607h Dear Mr.Deptula: This letter is to confirm our conversation regarding subsurface sewage disposal for the residence presently under construction on the property of John Midlin, Route 5,South Windsor,on the occasion of our inspection of the property on July l,1980. The house is presently under construction,but has been moved from the location indicated on the original plan approved by this office.The house sewer eleva- tions have been set too low,so that it is not possible to construct the leach- ing system in fill in the area originally proposed.As you know,most of this property is underlain by an impervious clay layer at a relatively shallow depth. One possible way of constructing a gravity sewage disposal system would be to locate the leaching system on the slope of a shallow ravine north of the build- ing.Two observation pits were dug in this area.The upper hole showed a depth of about 3 feet of sandy loam,underlain by clay.The lower hole showed a depth of about 1%feet of medium loam underlain by a sandy clay.No ground water was apparent,and it appeared that a leaching system constructed in the area of these test holes would allow for gravity flow,and still be located at least 50 feet from the watercourse at the bottom of the ravine. The following recommendations were made for design of the system: l.300 feet of 3-foot wide leaching trench should be used.These trenches would have to be in two rows along the hillside in order to allow for gravity flow and be sufficiently far from the watercourse.Four 75-foot long trenches could be used,extending in both directions from central distribution boxes. 2.The invert of the upper trench should be located approximately at existing grade,while the invert of the lower trench should be approximately 12 inches above existing grade.This would require about l foot of fill at the upper trench,and 2 feet at the lower trench.The fill should be extended for a distance of 25 feet beyond the lower trench to assure that sewage effluent does not surface.A serial distribution arrangement is recommended. 3.Before revised plans are prepared or the system is installed,itiNill be necessary to run a profile of the existing sewer,septic tank and the ground contours in the area of the proposed leaching trenches.The location and elevation of the system should be carefully staked to assure proper construc- tion.A revised plan,or as-built plan should be submitted. }%ona 566—2195 W w r WEE 79 Elm Street Hartford,Connecticut 06115 An Equal Opportunity Employer Ju1y 9,1980Mr.Robert Deptula,R.S.-2 South Windsor If you have any question,or if we may be of any assistance,please contact us. Sincere1y yours, fD/Lc‘a"?¢§m~(I mJ/véév Theodore C.Willerford Principal Sanitary Engineer Preventable Diseases Division Environmental Health Services Section TCW/pdp cc:$idney H.Curtis,M.D. Director of Health,South Windsor STATE OF CONNECTICUT DEPARTMENT OF HEALTH SERVICES 79 Elm Street -Hartford,Connecticut 06115 sum:$0 U‘\W '-*-‘‘N’V5C’&comm,REVIEH OF ENGINWNG Pym FOR A HOUSEHOLD SUBSURFACE smAGE DISPOSAL SYSTEM 'ONv ?K<>?€R~T’7 SF—man HVP I.)M) Ra Um is TO:R9%@{T $€VTV§AJ R.$.’,'T=>~.HQ i-tAaggv.govm LA.“Nmsq FROM:.TEEODORE C.WIILERFORD,PRINCIPAL SANITARY ENGEIEER,‘ mGINEERL éf’l i (—l—‘u <.&K.DATE RECELWEI)7/27 /‘7§ REASON FOR SWSSIOET: NEW CONSTRIETION REPAIR SHALLOW LEmE ROCK WE!ak ’mm Pmcommou RATE roomTEA}:30 MmEs/mCH EEGH MAW!GROUND WATER IEVEE. ‘orm €‘H Akcm u&%e&h\-nmc. CONDITIONAL APPROVAL SUBJECT To mm TESTING PRIOR To INSIAIIAIION As NOTED ONENCLOSEDPLAN.’ APPROVAL DmED.SITE UNSUTTABLE FOR SEWAGE DISP$AL. APPRGVAL DENIED.INSUFFICIEN'I.‘II‘E‘ORMATION ON PLAN. APPROVAL DENED.REVISE AS NUI‘ED ON ENCLOSED PLAN AND RESLEMT. APPROVAL DENIED.FURTEER SETE INVESTIGATION REQUIRED. 1~S?ec:ra3 Akw/OK t ‘?:e§=c.>Re fNSmCLtMg-C gW—uwc‘wsw Ci)d €M&(Mée{9\gmupb 5&3?‘dam smucrLgN -&ewc;t~\ HM $%ci<§W a?wusmucwcg COPIES TO: comm:U3 "RU-c...gwuvuu FSe: a Rm w/RRML?"3 D ENGIHERR T .MM M £4)[:1 arm cw ENVIROEE’TEI‘TTAL HEALTH SERVIC$'Dm ON Phone:566*2195 K M; gPEIGN SPECIE'ICATIONS: no.OF BEDROOMS A ?. 15¢ DESIGN mac.RATE '3 C3 mum/IN. $3‘f‘x‘3’=/0(a’1smicTANKlOMS. HLL SYSTEM 4 LA:Fm LEAOHINO sysrm mu‘é’s Saa— OURMIN BRAINS Mo ue, Rawmmn ACTION: APPROVAL APFROVAL mm PROVISIONS Nam)ON ENCLOSED PLAN.