HomeMy WebLinkAbout2015-9-28 - 112 Hayes Road - Water Potability Test3E
K...Aquatek Labs
3 Research Drive -Woodbridge,CT 06525
WATER ANALYSIS REPORT
TEST ID:C09231530
DATE SAMPLED:9/22/2015TO:KELLEY,COLIN &LAU RA SAMPLE POINT:NONE SPECIFIED
NO TREATMENT SYSTEM SPECIFIED
SAMPLED BY:WILLIAM J.STANLEY,JR.
CONCLUSION:
measures,followed by re—examination,are recommended.
P :Primary limit,used to judge potability
S =Secondary Iimit,recommended but not required
MRL =Minimum Reportable Level
*Limit exceeded
ND :None Detected
CT License #PH-0466,Aquatek Labs
Page 1 of 1 for test #C09231530
QM s ,3.1 W
David M.Graham PhD.
Laborat Dlr tor
RECEIVED
SEP 28 ZOIS
S
I‘v
OUTH WINDSOR
HEALTH DEPT.
Based on the above results,this water was not safe for drinking purposes at the time of collection.Corrective
PROPERTY LOCATION:112 HAYES ROAD -SOUTH WINDSOR,CT
BACTERIA LIMITS METHOD
*COLIFORM (total)D ABSENT PRESENT ABSENT P 5M 9223
E.COLI (fecal)ABSENT D PRESENT ABSENT P MSM 9223
CHLORINE ABSENT D PRESENT ABSENT
PHYSICAL PARAMETERS RESULT UNITS LIMITS MRL METHOD
pH 7.5 SU 6.4 -10 S o SM 4500-H B
TURBIDITY 0.85 NTU 5 0.19 SM 2130 B
COLOR ND cu 15 S 5 SM 2120 B
ODOR 1%TON 2 s SM 2150
CHEMICALS RESULT UNITS LIMITS MRL METHOD]
FLUORIDE ND mg/L 4 P 0.3 EPA 300.0
CHLORIDE m 1*68 DIS/L 25M P 3 EPA 300.0
NITRITE NITROGEN ND mg/L 1 P EPA 300.0
NITRATE NITROGEN 3.6 mg/L 10 P EPA 300.0
SULFATE 13 mg/L 250 S EPA 300.0
CALCIUM 49 mg/L NONE 0.5 SM 3111 B
MAGNESIUM 7 mg/L NONE 0.5 SM 3111 B
HARDNESS 151 ..g/L 200 s .,4 SM 2340 B
SODIUM 11.4 mg/L 28 S 0.5 SM 3111 B
COPPER ND mg/L 1.3 s 0.04 SM 3111 B
IRON ND mg/L 0.3 S 0.04 SM 3111 B
MANGANESE NO mg/L 0.05 S 0.04 SM 3111 B
RADON WATER RESULT UNITS LIMITS MRL METHOD
SINGLE RADON WATER 2754 pCI/L 5,000 S 51 SM 7500-Rn