Loading...
HomeMy WebLinkAbout10 BALSAM FIR RDElectric # qwow APPLICATION FOR BUILDING PERMIT Plumbing# !3QQtcT,I 10 Bal s 21m Fir Road Date: 1 HVAC # Sprinkler# 22 r,. FINAL APPROVALS Estimated Cost c. E00" SIGN Permit FeeBuildingPLETEREDBOXEDAREASOccupancy Fee $ Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $Affidavit Appr. for CO. ON REVERSE SIDE / Total Fee TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT Additional Cost) $ The undersigned hereby applies to do work according to the following: Lot No. oZ I—Applicant 1 M O )' a Location of WorkL 0 ( AtZA. t:r Address oe C Tel. #Applicant's Town S-.,IA1 SaQ T Zip d G7 Lic.# /G b Owner Architect a_d x 931 r Owner's Address Architect's Address Zip Sc•+-44i LT Zip06 64-o 5 Sq. Ft. New Area: 1st FI. d` o n 2nd FI. 700 3rd FI. Total New Area d700 , Purpose of this permit wk_ City Water' Wello Septic System Sewed Ins: HO SP Cert. ea Basement Garage Approved by Date Use Group Construction Type Revised 8/02 OM3 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in vj& h this building nd is use is allowed. Signed I hereby apply for a Certificate of Occ pajycy for the work dejcr ed in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS 977 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 06/29/2009 FEE: GIS ID:07150010 ZONE: MUNIS APPLICATION# 200900083 THIS IS TO CERTIFY THAT 10 BALSAM FIR ROAD UNDER APPLICATION NUMBER 200900083 CONFORMS SUBSTANTIALLY TO THE REQUIREMENTS OF THE CONNECTICUT BASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE TOWN OF SOUTH WINDSOR AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: APPROVED FOR OCCUPANCY NEW HOME.2700 SF. SPECIAL CONDITIONS NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 2/3/2021 8:44 AM ANY CHANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES A NEW CERTIFICATE OF OCCUPANCY 977 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 06/29/2009 FEE: GIS ID: 07150010 ZONE: MUNIS APPLICATION# 200900083 THIS IS TO CERTIFY THAT 10 BALSAM FIR ROAD UNDER APPLICATION NUMBER 200900083 CONFORMS SUBSTANTIALLY TO THE REQUIREMENTS OF THE CONNECTICUT BASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE TOWN OF SOUTH WINDSOR AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: APPROVED FOR OCCUPANCY NEW HOME.2700 SF. SPECIAL CONDITIONS NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 2/3/2021 8:44 AM ANY CHANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES A NEW CERTIFICATE OF OCCUPANCY 977' TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER CERTIFICATE OF OCCUPANCY DATE: 06/29/2009 FEE: GIS ID: 07150010 ZONE: MUNIS APPLICATION# 200900083 THIS IS TO CERTIFY THAT 10 BALSAM FIR ROAD UNDER APPLICATION NUMBER 200900083 CONFORMS SUBSTANTIALLY TO THE REQUIREMENTS OF THE CONNECTICUT BASIC BUILDING CODE AND THE ZONING REGULATIONS OF THE TOWN OF SOUTH WINDSOR AND IS HEREBY APPROVED OF OCCUPANCY AS INDICATED BELOW: APPROVED FOR OCCUPANCY -NEW HOME.2700 SF. r SPECIAL CONDITIONS ti . NOTICE: IF THIS CERTIFICATE IS LOST OR DESTROYED,A DUPLICATE SHOULD BE OBTAINED IMMEDIATELY FROM THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 2/3/2021 8:44 AM ANY CHANGE OR EXTENSION OF THE USE HEREIN APPROVED REQUIRES A NEW CERTIFICATE OF OCCUPANCY INSPECTION FIELD SHEET 02/03/21 Printed by Middleton, Morgan 08 43 51 INSPECTION: 21112 FOUNDATION PERMIT: STATUS APPLICATION: 200900083 LOC: 10 BALSAM FIR ROAD PROPERTY ID: 07150010 OWNER: MANNARINO BUILDERS INC CONTRACTOR: REQUEST BY: PROJ DESC: NEW HOME. 2700 SF. WORK ORDER: INSPECTOR: ROSE RESULT: PASS REQUESTED: 02/18/09 PRIORITY: SCHEDULED: 02/23/09 AM COMPLETED: 02/23/09 UNPAID FEES: 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: ROB ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 02/13/09 FLAN PASS B001 FOOTING 05/01/09 ROSE PASS B001 FOOTING PEIRS FOR DECK 04/17/09 FLAN PASS B003 FRAMING (ROUGH) WITH MARK 04/21/09 DOUG PASS B004 INSULATION 06/23/09 DOUG N/A B005 FIREPLACE / CHIMNEY 06/23/09 DOUG PASS BO10 FINAL 04/17/09 FLAN PASS E001 ELECTRIC SERVICE WITH MARK OK TO RELEASE TO NU 02/25/09 ROSE PASS E002 ELECTRIC UNDERGROUND CONDUITS FROM HOUSE TO STREET 04/17/09 FLAN PASS E003 ELECTRIC ROUGH WITH MARK 04/17/09 FLAN PASS H003 HVAC ROUGH WITH MARK 06/23/09 DOUG N/A P002 PLUMBING UNDERGROUND 04/08/09 FLAN PASS P003 PLUMBING ROUGH WITH MARK 05/22/09 ROSE PASS P004 PLUMBING GAS TEST PRESS. TEST ON GAS PIPING INSPECTION FIELD SHEET 02/03/21 Printed by Middleton, Morgan 08 43 51 06/29/09 LIPE PASS Z003 CO PLANNING INSPECTION SITE COMPLIANCE CHECKLIST TOWN OF SOUTH WINDSOR,CONNECTICUT BUILDING PERMIT***** ADDRESS_l0 Er aS&M rl Y LOT/UNIT# Reviewed by_b.D Engineering) CONTACT/DEv_ naylvL6-Z, d Date Reviewed / 009 rov nied PH#Or a'6C("10 Reviewed by Planning) Date Submitted b 1 aOol Date Reviewed prov Denied In accordance with the Zoning and/or Subdivision Regulations,prior to the building of any structure on a lot,a TopographicPlotPlanshallbesubmittedforapproval. The minimum requirements shall include: Approved Denied N/A 1. Name,address&phone number of owner/applicant 2. Name,address&phone number of plan preparer 3. Zoning Information—Le.zone,open space, floodway,street address 4. Plot Plan at 1"=40'scale a. Subdrvrsron reference,abutting properties,etc. b. Easements of record C. Lot description,bearings,building lines, distances,area,etc. d. Contours,eAsting&proposed, 1 Or 2ft.interval where appropriate r/ e. Building location with dimensions.Elevations of proposed finish floor,garage floor&centerline of road at driveway f. Elevations of gravity drainage systems,sanitary foundation drain at the house and the street g. Tentative utility location(gas,water,electric, septic system,etc h. Title block with name&address of preparer, date,appropriate certification live seal&live signature consistent with the Board of Registration requirements.(P.E.&LS.) y—S. Sedimentation and erosion control v 6. Special Planning&Zoning,Inland/Wetlands considerations(Plans on file w/Town Cleric) COMMENTS: i s/engineering/molloy/building compliance checklist DI-=PARTMENT DI:CISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 0T --_ APPROVE 1540 SULLIVAN AVENUE Bldg. Permit# dc 644-2511 ext. 230 Date Building Inspect Application must be printed or typed FEE SCHEDULE Location of Job: 1 0-$1,000=$15.00 Street No. Street Lot No.Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS APPLICANT PHONE# O W N $F,q OWNER zv0 z%I ez ^ izy e,-) r 52 OWNER ADDRESS Q OWNER PHONE 77 ESTIMATED COST$ t, V IS THIS A CONTRACT COST? _Yes No 4 FEE ENCLOSED$ CL rvrl of Jol:Ij5 oR C Ncw Installation Allcr iwir AdditioII/1Zcl)air APPLICATION FOR HVAC PERMIT (Continued from reverse side) FYPE OF SYSTEM: TYPE OF BUILDING: AHEATING a-RESIDENTIAL A'C Cl COMMERCIAL O VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. O HYDRONIC Z-WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION 'TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE Z5— °F DIFFERENCE F TOTAL HEAT LOSS (BTUH)&pjye°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE& MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) L)C NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION : INSIDE OUTSIDE CAPACITY GAS—INPUT/C LPG TANK CAPACITY___ ELECTRIC—KW _ AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE 749 OF DIFFERENCE Z- 5 °F TOTAL HEAT GAIN(BTUH) 3( / (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING AKE& MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) Lf , VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TU COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. r 7ey6lV CONTRACTORS LICENSE NO. TYPE STAT SIGNATURE OF APPLICANT V DATE / 10 Balsam Fir Rd., Lot #25 HVAC Load Calculations for Mannarino Bids i RHVACREsIDEN"TYAL HVAC LOADS Prepared By:I Stephen Smith Advanced Htg&AC Inc Wednesday,April 01, 2009 Rhvac-Residential&Light Commercial HVAC Loads Elks Software Development, Inc.' Advanced Htg 8 A/C 10 Balsam Fir Rd., Lot#25 South Windsor,CT 06074 16 Page 33 System 1 Room Load Summary Htg Run Run Clg Clg Cig Zone Clg Room rea Sens Nom Duct Duct Sens Lat Nom Adi Adi SroNameSFBtuhCFMSizeVelBtuhBtuhCFMFactCFMCF Zone 1--- 1 Kitchen 256 6,158 80 2-6 464 4,009 828 182 1.30 237 182 2 Laundry/powder 152 4,199 55 1-4 609 1,169 939 53 1.00 53 53 3 Dining 182 5,175 67 1-5 480 1,438 322 65 1.00 65 65 4 Lower Foyer 111 3,993 52 1-4 591 1,133 304 52 1.00 52 52 5 Study 182 5,656 74 1-5 588 1,762 304 80 1.00 80 80 6 Master Suite 479 10,058 131 2-5 640 3,836 479 174 1.18 205 174 7 Lower Family 528 11,159 145 1-7 496 2,917 810 133 1.35 179 133 Zone 1 subtotal 1,890 46,398 603 16,264 3,986 740 872 740 Zone 2--- 8 Bed 2 176 4,651 60 1-5 542 1,625 295 74 1.17 87 74 9 Loft/lav 256 2,711 35 1-4 610 1,171 74 53 1.00 53 53 10 Bed 3 169 3,920 51 1-4 702 1,347 258 61 1.00 61 61 11 Upper Foyer 111 4,075 53 1-5 520 1,558 276 71 1.00 71 71 12 Upper Family 528 10,096 131 2-6 591 5,104 654 232 1.35 313 232 Zone 2 subtotal 1,240 25,453 331 10,805 1,557 491 585 491 System 1 total 3,130 71,851 934 27,069 5,543 1,231 1,457 1,231 System 1 Main Trunk Size:14x16 in. Velocity: 882 ft./min Loss per 100 ft.: 0.096 in.wg ystem Summary Cooling Sensible/Latent Sensible Latent TMOOMMiotB' Tons Split Btuh Btuh Bt Net Required:2.72 8A l 170/6 27,069 5,543 32,612 Recommended: 3.01 75%/25% 27,069 9,023 36,092 Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Applic ' L TOWN OF SOUTH WINDSOR PERMIT# 9wo4-6BUILDINGDEPARTMENT PRO 1540 SULLIVAN AVENUE Bldg.Permit# Z 644-2511 ext. 230 ObDatedingInspector Application must be printed or typed FEE SCHEDULE Location of Job: 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT TT 171 LC Z-L VC `1J G APPLICANT ADDRESS SAD /0 -f7 T APPLICANT PHONE# K- 7o O W N SF OWNER C OWNER ADDRESS O 6 /?i2,4O OWNER PHONEp , f?9 - 70s3 C ESTIMATED COST$ 7S0 D IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ /02 O. s,O. ON TYPE OF JOB: 0 I lRCNewInstallationI` O Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A la RESIDENTIAL BUILDING PERMIT APPLICATION? OYES NO Q BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE FUTURE USE AND OCCUPANCY A16 JEDUCATIONAL INSTITUTIONAL FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE aZ(7r /Q/1'I SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS r_ NUMBER OF PANELS /REMOTE DISCONNECT REQUIRED? Q YES 3440 NUMBER OF LIGHT CIRCUITS 1 :2— NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES -'IS NUMBER OF OUTLETS ZO NUMBER OF LIGHT FIXTURES 3C' NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. d 3 71p 2- — /C-T" CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT ey DATE GZ 9 TOWN OF SOUTH WINDSO AFFIDAVIT OF ACTUAL CO TS . DrIKK . d loos PERMIT NO: 2,6QdJ;K DATE 9ouut dindsor w The undersigned, being a duly authorized representative of, do by this statement, certify that the actual costs shown below, of the project referenced by the Permit Number shown above,are true and accurate. This statement is being made pursuant to the Town of South Windsor Ordinance, Article II, Section 14-31, a)thru(e),(see attached). understand that verification for accuracy of actual costs may be made at any time by the Building Official through an appraisal of the work at the expense of the property owner. hereby certify that the actual cost of the work performed under this permit Is: 5Dd Signature of Permit Holder J Name(Please Print) `! h 0»-,a ) DJ-z' Date: 3 I a.6 to araaraaaarrarrrraaaraaarrararraaaraararraarraarraaaraaarrarrrararraaaaara arrr• State of Connecticut] ss South Windsor Date: County of Hartford] Personally appeared as aforesaid, Signer and sealer-of the foregoing instrument and acknowledged *the same to be his/her free act and deed, before me. Notary Public Commissioner of the Superior Court My commission expires on i Revised DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# App . TOWN OF SOUTH WINDSOR gCo0-ABUILDINGDEPARTMENT 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 IoOo Date ng Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 1` APPLICANT ADDRESS APPLICANT PHONE# 019 N S Z-4 OWNER C OWNER ADDRESS 0 O OWNER PHONE 7, -04 C ESTIMATED COST$T_1 IS THIS A CONTRACT COST? Yes _No G FEE ENCLOSED$Z u ` D 1 TYPE OF JOB: f Ins S R_Cod New Installation I a` LJ Alteration/Addition/Repair APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION? YES NO BUSINESS CURRENT USE AND OCCUPANCYASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCYEDUCATIONAL INSTITUTIONAL FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE Other please specify) CITY STATE ZIP TYPE OF INSTALLATION 2 '! z b c -\ h SIZE OF MAIN DRAIN 1A NO.OF TOILETS_ STYLE NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES ] NO.OF CONDUCTORS SIZE 3 NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW DYES NO SIZE OF WINDOW 2 Xz IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWEt OR SEPTIC TANK SIZE OF WATER MAIN 1 SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER \ a_ DESCRIPTION OF WORK C ITE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS T7— COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Cl CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE S,- Z'A/p °` Ivor) Szv SITE COMPLIANCE CHECKLISTPTOWNOFSOUTHWINDSOR,CONNECTICUT 6617W pg ` 10 FOR C OF O***** Q IJIJLW r aLOT/UNIT# ' Reviewed by -L Engineering) CONTACT/DEVc /ZL^1 Date Reviewed tp nrrsvtni/Denied PH# Reviewed by, Planning) Date Submitted Date Reviewed Date Reviewed Approved/Denied (Health) As required in the Zoning and/or Subdivision Regulations,no Certificate of Occupancy shall be issued until gradingplanshavebeencompliedwithandapprovedbytheTownEngineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e.trees,shrubs, dumpsters,required parking 4. Utility location; a. sanitary sewer/septic systems b. foundation drain C. electrical&telephone d. water e. other 5. Sewer Connection charge paid 6. Appropriate certification 7. Bonding 8. Planning&Zoning/ vr Inland Wetlands Considerations a. Lighting b. Signage Freestanding Wall C. Fee in lieu of Open Space y ,COMMENTS: t'.R j, S Ito<,;S kiL. E.: ltren 6 . C's1,11 ,.er v e,— _ IV412 o s/engineering/molloy/site compliance checklist I Ix NO TtS - 1. AREA OF LOT 25 = 28,559 SQ.FT. = 0.656 ACRES 2. ZONE OF SUBJECT PARCEL IS A-30 OPEN SPACE". MINIMUM YARD REQUIREMENTS., FRONT = 40 FEET SIDE = 10 FEET REAR = 20 FEET J. BOUNDARY INFORMA77ON TAKEN FROM PLANS EN77TLED - 64 2S DZEN TREE FARM SUBDIVISION PLAN PREPARED FOR MANNARINO BUILDERS, INC. MASKEL ROAD AND BARBER HILL ROAD SOUTH W/NDSOR, CONNEC77CUT SCALE" 1 IN.= 40 FT. DATE. AUGUST 29, 2007 REVISION DATES TO 6-17-08 SHEETS Sl, S2, S3, S4 AND S5 ALFORD ASSOCIATES, INC. CIVIL ENGINEERS WINDSOR, CONNECTICUT" 4. APPLICANT MAP PREPARED BY- MANNARINO BUILDERS, INC.ALFORD ASSOCIATES, INC. YD #11 ROBERT MANNARINO 200 PIGEON HILL ROAD TF=258.5 400 CHAPEL ROAD, SUI7E 3-F P.O. BOX 484 ZONE SOUTH WNDSOR,------- TEL. # (860) 289CONNEC77CUT 06074 WNDSOR# (, CONE 7288 06095 7055- Jo„ .ZONE S 867 464" W 5. ELEVATIONS ARE BASED ON NGVD29. 132.26' 6. NO ZONING WOLA77ONS WITH RESPECT TO LOCA77ON OF EXIS77NG FOUNDATION, AS SHOWN. RIGHT TO DRAIN RIGHT TO DRAIN` 20'/?y -'-' 7. EXISTING HOUSE - 274.3+ GARAGE FLOOR ELEVA77NN = 275.93 271.5 270.5 FIN/SHED FLOOR ELEVA77NN = 278.10 ID I#913 BASEMENT FLOOR ELEVA77NN = 268.60 (WALKOUT) 268.2 7F' 260 2 265.1 \ 262.3 (PRIVATE) o ` 8. LEGEND - A 27 3 EXIS77NG CONTOUR 266.4 n24 2721 .I. \ c.A x 310.0 EXIS77NG SPOT GRADE 269.7 N + 264.3 1 W WATER SERVICE z77 o NP, 1 25 264.7 DURING PHASE 1, SURFACE W47ER SHALL BE FD F0077NG DRAIN LINE cn 267.1+ en DIRECTED TOWARDS THE EX/S:9NG SWALE TOWARDS N \ THE SOUTH. AT 77ME OF PHASE 2, YARD DRAIN #9B Cv CHECK VALVE AT HOUSE FOR F0077NG DRAIN TO BE INSTALLED rn 27zs SANITARY SEWER LATERAL 27t o 268 2 zss.s+ \ G GAS SERVICE N 269.9 T,E, 277.6 269.8 266.9 N TELEPHONE, ELECTRIC AND CABLE TVSERNCES v 15.2' GM o GAS METER 27s.o 2.9'xs' N 073742" W 272 6 8.3' DECK CONC. PAD l 2G277.9 4.7' 5' s y? 5' 3s I 107.75' OV EM o ELECTRIC METER 273.0 273.0 4 5' 25.3' 2'5 I AC AIR CONDlT10N/NG UNIT AND CONCRETE PAD 277.7 273.83 274 5GV274.12 AC p w GAS GATE EXISTING HOUSE 273.4+ CONC. PA ' 3'FD FL= 267.4E TV CABLE TV BOX SE SAN. FL= 270.5 12 000 275.91 8.0' GM 3 ELEC ELECTRIC MAN HOLE EX 11NG 14.6'13. 270.2 IS 280.3 a 20.9' ? EM o CV 16.2'LIGHT POLE 2741+ 275.06275 92 24 7'1 10.3' COVERED ENTRY WV27 .1 OVER FRONT STOOP 1 3 WA TER GA7F 40' I CONCRETE PAVER WALK N N 1 274.8 I 271.3 rn rn 275.1 1 0 A 275.9 . 'yA BITUMINOUS CONCRETE { F DRIVEWAY 274.3 272.4 273.3 TV ELEC 7 277.32 Z g.33 27 .27 t 9 277.03 276.09 273.28 20' WIDE STREET TREE EASEMENT IN FAVOR OF THE TOWN OF BALSAMSOUTHW]NDSOR TF- 1s -FAR ROAD Bt SEWER A A TER MAIN 10' WIDE C.L.& P. CO. EASEMENT AND 10' WIDE YANKEE GAS EASEMENT 5.16 4' WIDE CONCRETE WALK R=275.00' L=94.92 D=1946 38"CB 1120 7F= 274.64 FL, OUT W= 264.57 FD FL= 266.7 SAN. MH #14 7F= 274.24 SANITARY SEWER LATERAL FL= 266.6E SANITARY SEWER LATERAL FROM HOUSE TO SAN. MH #14 THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SEC77ONS 20-300b-1 THROUGH 2O-300b-20 OF 774E REGULA77ONS OF CONNECTICUT STATE AGENCIES- "MINIMUM STANDARDS FOR SURVEYS AND MAPS /N 774E STATE OF CONNECTICUT" AS ENDORSED BY 7HE CONNECTICUT ASSOCIA77ON OF LAND SURVEYORS, INC.. IT /S A LIMITED PROPERTY/BOUNDARY SURVEY BASED ON A DEPENDENT RESURVEY CONFORMING TO HORIZONTAL ACCURACY CLASS A-2 AND INTENDED TO BE USED FOR AN IMPROVEMENT LOCA77ON SURVEY. GRAPHIC SCALE NNe w, d OFrrN,i' w TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS NtJ ao o ao Bo eeee o,,,.ALFI,.... eee'44, '' M••ALF j7 PREPARED FOR MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. All MANNARINO BUILDERS, INC. IN FEET ) f. z L.S. N0. 9344 s=IMPROVEMENT LOCATION SURVEY No S 3k Y`' ' < i No. 9344 a CIVIL ENGINEERS THE LOCATIONS OF UNDERGROUND UTILITIES ARE 9-30-09 ADDITIONAL AS-BUILT GRADES AT THE a ek DZEN TREE FARM WINOSOR coNNECTfCUTREAROF774EHOUSEoAoF:/CENSE••a`eee tq:.!cENSEo,y'eeeeAPPROXIMATEANDALLUTILITIESMAYNOTBEFs'''••"'EN•• o^Vo su Ri ,o`S/ONAL o##$i i....iu WILSON M.ALFORD,JR.,P.E.? L.S.SHOWN. PRIOR TO CONSTRUCTION, CONTRACTOR 6-23-09 ADDED AS-BUILT HOUSE, U77LI77ES AND GRADES LOT 25 -SHALL CALL 1-800-922-4455 AND HAVE THE DATE REVISION 10 BALSAM FIR ROAD SOUTH VANDSOR, CONNECTICUTUTILITIESMARKEDONTHEGROUND. NOT VALID WITHOUT A LIVE S GNATURE AND EMBOSSED SEAL SCALE: 1 IN. = 40 FT. DATE: FEBRUARY 11, 2009 D:M08060PP-25 P:M06024 FOLDER:MANNARINO FILE:MANNARINO-DZEN RECEIVED uu, U 5 2009 SOUI h vvnUDSOR ENGINEERING DEPT. THIS SURVEY AND MAP hAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS NO TES 20-300b-1 THROUGH 2O-300b-20 OF THE REGULA77ONS OF CONNEC77CUT 1. AREA OF LOT 25 = 28,559 SQ.FT. = 0.656 ACRES. STATE AGENCIES- "MINIMVM STANDARDS FOR SURVEYS AND MAPS IN THE 2. ZONE OF SUBJECT PARCEL IS A-30 OPEN SPACE" STATE OF CONNEC77CUT" AS ENDORSED BY THE CONNEC77CUT ASSOCIA770N OF LAND SURVEYORS, INC.. IT IS A LIMITED PROPERTY/BOUNDARY SURVEY MINIMUM YARD REQUIREMENTS: n rr,r.,nc.,r n irnticv nnA/cnou/A/n Tr) W-1A17MITAI ACr'lIPA ry FRONT= 40 FEET BASED UIV H UCl'CIVUCIV I ICCJU/S VG/ t v1 vF L/v11w11 vv I v „vn,cv.•.r i w.+.+...,... SIDE = 10 FEET PROPOSED o CLASS A-2 AND INTENDED TO BE USED FOR AN IMPROVEMENT LOCATION SURVEY. I REAR = 20 FEET HORSE mo 3. BOUNDARY INFORMATION TAKEN FROM PLANS EN777LED - JJJ 64 28 v DZEN TREE FARM SUBDIVISION PAN PREPARED FOR MANNARINO BUILDERS, INC. MASKEL ROAD AND o BARBER HILL ROAD SOUTH WINDSOR, CONNEC77CUT SCALE" 1 IN.= 40 FT. DATE. AUGUST 29, 2007 REVISION DATES TO 6-17-08 SHEETS S1, S2, S3, S4 AND S5 ALFORD ASSOCIATES, INC. CINL 268 5 25g p o ENGINEERS WINDSOR, CONNEC77CUT' 269.5 260.5 4. APPLICANT' MAP PREPARED BY 268.5 MANNARINO BUILDERS, INC.ALFORD ASSOCIATES, INC. 269,0 1.C/oROBERT MANNARINO 200 PIGEON HILL ROAD 400 CHAPEL ROAD, SUI7E 3-F P.O. BOX 484 o SOUTH WINDSOR, CONNEC77CUT 06074 WINDSOR, CONNEC77CUT 06095 RR" ZONE TEL. 1 (860) 289-7055 TEL. # (860) 688-7288 S 8676'44" Ly yT ELE AT10NS ARE BASED ON GVD29.ZONE _ A T 17ME OF PHASE 1, l- 5 V A N 132,26' EX/STING PIPES SHALL BE 6. NO ZONING V10A710NS WITH RESPECT TO LOCATION OF HOUSE, IF ERECTED AS SHOWN. 6 I"XIS REMOVED 7. CONTRACTOR SHALL VERIFY LOCA71ON AND ELEVA71ON OF EXIS77NG U77LI71ES PRIOR TO ESTABLISHING FINAL RIGHT TO DRAIN T.SIVALE 20 R 262j 263.0 GRADE OF PROPOSED FOOANGS AND FOUNDA710N. CONTRACTOR SHALL INSTALL TEMPORARY EROSION CONTROL EXIS , ~ -MEASURES FOR STOCKPILED MATERIAL AND AT TOPS OF SLOPES DURING FOUNDATION EXCAVA770N. IRA FABRIC r 15" PIPES o SILT FENCE AND OR TEMPORARY VEGETA77ON IF PILES ARE TO REMAIN IN PLACE FOR EXTENDED PERIODS OF TIME. RIGHT TO DRAIN PRIVZ° `;` - W 8. DUR/N CONS7RUC710N, M/RAFI FABRIC CHECK DAMS ALONG SWALES MAY BE REQUIRED BY TOWN STAFF ATE) 6 0 9. LEGEND - p24 27 EXIS77NG CONTOURONz26 .0 263.0 x 310.0 EXISTING SPOT GRADE cis PROPOSED CONTOUR DURING PHASE 1, SURFACE WATER SHALL BE DIRECTED TOWARDS THE EXIS77NG SCALE TOWARDS 3f0.0 PROPOSED SPOT GRADE THE SOUTH. AT 77ME OF PHASE $ YARD DRAIN #9B TO BE INSTALLED GRADE TO DRAIN m SURFACE WATER IS TO BE DIRECTED AWAY FROM THE HOUSE AND GARAGE 26 .0 W PROPOSED WATER SERVICE FD_ PROPOSED 6"0 F0077NG DRAIN LINE CV CHECK VALVE IS REQUIRED ON F0077NG DRAIN LINE AT HOUSE N 0737'42" W G PROPOSED GAS SERVICE TO CONNECT TO EXIST. IN STREET 266.5 I 10Z 75 26 T PROPOSED TELEPHONE SERVICE TO CONNECT TO EXIST. IN STREET gA 272.0 ss E PROPOSED ELECTRIC SERVICE TO CONNECT TO EXIST. IN STREET 22js N PROPOSED HORSE s CONSTRUCTION ENTRANCE PAD-S 82 Ni FD FL=',266.1 NOT TO SCALE MlRAFI FABRIC FENCE - TO BE PACED PRIOR TO ANY CONSTRUCTION AND o i SHALL REMAIN IN PACE UNIX DISTURBED AREA IS STABILIZEDSAN. fL= 268.1 27U 2,0,0EN HOUSE BALSAM FIR ROAD SEp NO J 0 62'4" ro N PROPOSED H o o 0 0°0 10. PROPOSED HOUSE - PROpO cv I o o' oo PROPOSED GARAGE FLOOR = 275.0 2 N o u o 0 00 0 PROPOSED TOP OF FOUNDATION = 276.0 0 - I 73.0 N PROPOSED F7NISHED BOOR = 277.0 LDS. 2 4 2 o 0 0 o 0 o N APPROXIMATE BASEMENT FLOOR = 267.3 (WALKOUT) I 40' i N o fp V) 2715 o 0 o 0 o TOP OF FOUNDA7ION TO BE A MINIMUM OF EIGHT(8) INCHES ABOVE THE FINAL EXTERIOR GRADE. 6 I o 0 0 0 00 0 MIN.0 0 0 0 0Qb USE GARAGE FLOOR ELEVA77ON TO SET GRADE OF THE HOUSE. ADJUST OTHER FLOOR ELEVA77ONS 3. 277.5 o o o o oE BASED ON THE ARCH17ECTURAL PANS. 27g,0 o 11. PRIOR TO STAR77NG C0NS7RUC77ON, THE CONTRACTOR SHALL BE RESPONSIBLE TO MAKE SURE 7HAT ALL FABRIC2jRN 2 8.6 27CONSTRUCRON OR 3 PLAN 4" MINIMUM CONN. BEGINRUN77L THECONTRACTOR ED PERM17S AND OHAS RECEIVEDVALSHAVEEANDBTHOROUGHREVIEWEDALLPLANSANDAOTHERHALL DOT 2" STONE DOCUMENTS BY ALL OF THE PERMITTING AU7HOR177ES, FILTER FABRIC N 277.1 YIDTHa 10' MIN. 20 WIDE STREET 7REE EASEMENT to-2 0 r' IN FAVOR OF THE TOWN OF ti F- BgLSq,y FTR R0g0 a a SAN. S NOTES: SECTION SEEDING SCHEDULE - SOUTH WINDSOR s I EWER 1. THE PURPOSE OF A STABILIZED CONSTRUCTION ENTRANCE IS TO REDUCE ZSD // 8'WAR!1AIN THE TRACKING OR FLOWAGE OR SEDIMENT ONTO EXISTING PAVEMENT. ALL DISTURBED AREAS NOT PAVED OR LANDSCAPED SHALL BE LOAMED WITH 10' WIDE C.L.& P. CO. EASEMENT 15 2 BEFORE CONSTRUCTION ENTRANCE INSTALLATION, THE AREA OF THE 4" MINIMUM OF TOPSOIL.. SEED AS INDICATED BELOW. CONDITION SOIL AND 10' WIDE YANKEE GAS EASEMENT SAN• MH#6 ENTRANCE SHOULD BE CLEARED OF ALL VEGETATION, ROOTS AND OTHER WITH FERTILIZER AND LIMESTONE AS INDICATED BY SOIL TEST. TF UNDESIRAB_E MATERIAL PERMANENT VEGETATIVE COVER: 4' WIDE CONCRETE WALK 3. THE ENTRANCE SHOULD BE MAINTAINED IN A CONDITION YMICH WILL SEEDING DATES: APRIL 1 TO JUNE 15 & SEPTEMBER 1 TO OCTOBER 15 R=275.00' PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO EXISTING PAVEMENT. OR AT OTHER TIMES, WEATHER PERMITTING L=94.92 THIS WILL REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR i ADDITIONAL LENGTH AS CONDITIONS REQUIRE. LAWN AREAS: 19'4638"CB #20 USE THE FOLLOWING MIXTURE OR EQUAL AS APPROVED BY DESIGN ENGINEER: TF= 274.37 KENTUCKY BLUEGRASS 45% 1 FL, OUT W= 264.57 CREEPING RED FESCUE 45% EXIST. FL FOR FD= 267.37 PERENNIAL RYEGRASS 10% PROPOSED FD FL= 265.7 APPLY 1-3 LBS./1000 S.F. SAN. MH #14 TEMPORARY VEGETATIVE COVER: INSTALL CONSTRUCTION ENTRANCE PAD 7F= 274.24 SEEDING DATES: MARCH 1 TO JUNE 15 & AUGUST 1 TO OCTOBER 15 PRIOR TO ANY CONSTRUCTION SANITARY SEWER LATERAL FL= 266.6.E OR AT OTHER TIMES, WEATHER PERMITTING A MINIMUM OF 20 FEET LONG) USE THE FOLLOWING SEED OR EQUAL AS APPROVED BY DESIGN SANITARY SEWER LATERAL FROM HOUSE TO SAN. MH #14 ENGINEER - 74'- 6-0 0 2.0% (MINIMUM SLOPE = 2.0%)ANNUAL RYEGRASS 100% APPLY 1 LB./1000 S.F. n...., TO THE BEST OF MY KNOWLEDGE AND BELIEF THIS GRAPHIC SCALE Oo'' c ti'''.4 )f o N7y '.. O OF ONI,iOj•. PREPARED FOR MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. 40 0 40 ao pPo`I ALFo"_ O4 Aq"o M ALFo MANNARINO BUILDERS, INC. 3 L.S. NO. 9344 IN FEET ) IMPROVEMENT LOCATION SURVEY No. 9344 No. 9344 aVIL ENGINEERS THE LOCATIONS OF UNDERGROUND UTILITIES ARE o l °• •'' DZEN TREE FARM I WINDSOR coNNEC1ICUT APPROXIMATE AND ALL UTILITIES MAY NOT BE Fs Ea . s U R SHOWN. PRIOR TO CONSTRUCTION, CONTRACTOR iwS/ONAL p somoo WILSON M.ALFORD,JR.,P.E.&L.S. LOT 25 - SHALL CALL 1-800-922-4455 AND HAVE THE 10 BALSAM FIR ROAD SOUTH WINDSOR, CONNECTICUT UTILITIES MARKED ON THE GROUND. DATE REVISION NOT VALID WITHOUT A LIVE SIGNATURE AND EMBOSSED SEAL SCALE: 1 IN. = 40 FT. DATE: FEBRUARY 11, 2009 D:MOSOBOPP-25 P:M06024 FOLDER:MANNARINO FILE:MANNARINO-DZEN i FE3 South W+ndsor BUILDING DEPARTMENT 18 THE St UIN6 DEFT. TOWN Of SOUTH WIWStk irhls cillwr0ed that this plan and six edicati,ins are M9 Icopieis, tl W propoead Wilding or altsrattons to a 1W.001 1 FIR t1, I A tt9reel together with amendments stated In application and filed with plan and I agree to comply with ail toning. SuIlding and state laws and such orders as ahMll be issued by the Building Department during pandahey of this application and final Issuance ofa bbulldin/ ip&:Y:: r Gt J 1 g Z^ roils plan Ys approved subject to the condhft that lorders and ordinances regulating building shail be complied with. C-Ddltiwaily Approved These Iliad With tuilding inspector IWf