HomeMy WebLinkAbout28 Amato Drive (10)CONNECTICUT STATE DEPARTMENT OF HEALTH SERVICES ENVIRONMENTAI HEALTH SERVICES SECTION
SOUTH WINDSOR, CT. ; EXAMINATION OF PLANS AND
S UBJ ECt""FICATIONS FOR A PROPOSED RENOVATION TO A PUBLIC
IttING POOL LOCATED AT WESTAGE CONDOMINIUMS
Paul Schur, Acting DirectorTO: Environmental Health Services Division
From: Frank Homiski , Senior Environmental Sanitarian
Recreational Health & Safety Program
Environmental Health Services Division
APPROVAL ISSUED: June 30, 1989
LOCATION: Amato Drive; South Windsor, CT.
ENGINEER OR ARCHITECT:
POOL PLANS RECEIVED: 6/12/89 REVISED PLANS RECEIVED:
POOL CONSTRUCTION FIRM: Century Pool Corp. , 260 Fairview Street, New Britain,
CT. 06051
APPLICATION SUBMITTED BY: Thomas J. Martin, Manager; Westage at South Windsor,
Condominium Association, Inc. ; P.O. Box 789; South Windsor, CT 06074
PROPOSED CONSTRUCTION: Existing
WATER SUPPLY: Existing
RECOMMENDED MAXIMUM BATHING LOAD: Existing
PLAN DIMENSIONS & CAPACITY: Existing
SLOPE OF BOTTOM IN SHALLOW AREA: Existing Construction
SLOPE OF BOTTOM 5 FEET TO MAXIMUM DEPTH:
VERTICAL WALLS (Deep En3):
DIVING BOARD:
EFFECTIVE DEPTH AT DIVING AREA:
MINIMUM HEIGHT OF CEILING ABOVE DIVING BOARD:
Page 1 of 3
FORM EHS-UA 9 84 SM
SOUTH WINDSOR, CT. : EXAMINATION OF PLANS AND SPECIFICATIONS
FOR A PROPOSED RENOVATION TO A PUBLIC SWIMMING POOI. LOCATED AT
WESTAGE CONDOI'INIUIIS
RECIRCULATING INLETS: Existing
OUTLETS/MAIN DRAINS: Existing
OVERFLOWS/SURFACE SKIMMERS: Existing
SUCTION CLEANER: Existing
CIRCULATING PUMP: (1) Purex tLTIK; 5 H.P. : Rated' at 195 G.P.M. at 50 Feet
T.D.H.
TIME FOR POOL TURNOVER: 64,400 Gallons = 5.5 Hours
195 G.P.M. x 60 Min./Hr.
FLOW GAUGE: (1) Blue White #CF30300P - 3 Inch Pipe Size; Scale 80 to 300 GPM
HAIR CATCHER: Integral with Pump
FILTER: (2) Pac Fab PTR-140 High Rate Sand Filter; 36 Inch Diameter NSF Listed
FILTER AREA: 14.12 Ft.2 Total Filter Area
FILTRATION RATE: 13.31 G.P.M./Ft.2 of Total Filter Area When Operating at
1.95 G.P.M.
BALANCE/SURGE TANK: N/A
SIGHT GLASS: (1 ) Hayward #SP-1074S
MAKE-UP WATER/PLACE OF INTRODUCTION:
CHLORINATOR: (1) Blue White #A-145-6; Capacity 81.6 G.P.D.
CHEMICAL FEED:
TESTING EQUIPMENT: Existing
UNDERWATER LIGHTS:
SHOWERS & TOILETS: Existing
1. MALE: Toilets, Urinals, Lavatory Sinks, Showers
2. FEMALE: Toilets, Lavatory Sinks, Showers
Page 2 of 3
SOUTH WINDSOR, CT. ; EXAMINATION OF PLATS AND SPECIFICATIONS
FOR A PROPOSED RENOVATION TO A PUBLIC S;4T'P, ING POOL LOCATED AT
WESTAGE CONDOMINIUIF)
BATHER ROUTING & FENCING: Existing
DECK AND DECK DRAINS: Existing Deck Feet Minimum Width Completely Around
Periphery of Pool
TOILET AND SHOWER WASTE DISPOSAL: Existing
FILTER BACKWASH WATER DISPOSAL: To Sanitary Sewer
DRY WELL SIZE AND CAPACITY:
POOL DRAINAGE:
Page 3 of 3