HomeMy WebLinkAbout28 Amato Drive (9)STATE OF CONNECTICUT DEPARTMENT OF HEALTH SERVICESa-e APPROVAL OF SW111T ]I NG POOL RENOVATIONS PLANS AND SPECIFICATIONS WESTAGE CONDOMINIUMS SOUTH WINDSOR, CT. Thomas J. Martin, Manager Westage at South Windsor, June 30, 1989 Condominium Association, Inc. P.O. Box 789 South Windsor, CT 06074 Dear Mr. Martin: The State Department of Health Services is in receipt of an application together with plans and specifications requesting approval of plans for the renovations of an existing outdoor swimming pool .located at Westage Condominiums. The swimming pool is keyhole in shape; has a water capacity of 64,400 gallons ; has a water surface area of 1,505 square feet ; and is to be provided with high rate sand filtration and automatic chlorination equipment. A review of the plans and specifications indicates that the proposed swimming pool renovations meets the Connecticut State Department of Health Services Regulations and Guidelines in accordance with the Public Health Code Section 19-13-B33b. Therefore, the application is hereby approved by the Commissioner of Health Services subject to the following provisions. The swimming pool and appurtenances are to be renovated in accordance with the details thereof as shown on such approved plans dated 6/12/89 and as outlined in the summary specifications form attached to this letter. Upon completion of the subject swimming pool renovation a STATEMENT OF CONFORN,ANCE shall be signed by the pool construction supervisor and an official of the pool construction firm. The signed statement shall be forwarded to the State Department of Health Services prior to use of the swimming pool or obtaining a certificate of occupancy from local municipal officials. Adequate pool maintenance shall be provided in accordance with Section 19-13-1333b of the Public Health Code to secure good operation. If necessary in the future, changes in operational procedure and/or equipment shall be made to produce satisfactory conditions. Written authorization shall be obtained from the State Department of Health Services for any construction or installation of equipment not shown on the plans or stated in the specifications. Page 1 of 2 Phone: 566-1259 150 Washington Street — Hartford, Connecticut 06106 An Equal Opportunity Employer APPROVAL OF SWIMMINTS POOL RENOVATIONS PLANS AND SPECIFICATIONS WESTACE CONDM1I:%JU1'S The subject swimmin^ pool prior to opening shall be provider! a:it}i a minimum of one unit of safety equipment for each one-hundred running feet of perimeter of the pool consisting, of the following: A ring buoy not more than fifteen inches inside diameter to which shall be attached a fiftv-foot length of one-quarter inch line and a shepherd's crook or reach pole with blunted ends, a minimum of twelve feet in length, such poles to be mounted in permanent sockets on opposite sides toward the deep area of the pool . A first aid kit American National Red Cross standard 24 unit kit or the equivalent) shall be provided and kept stocked and rea:y for use. A telephone which is readily available for emergency use shall be provided on'the premises. The operating instructions and isometric diagram of the pool equipment sh31 1 be mounted at a location in the filter room which is readily accessible for reading and is well illuminated. These instructions and diagram shall be mounted in a durable manner so as to resist damage from normal conditions in the filter room. Very truly yours, l Paul Schur, M.P.H. , Acting Director Environmental Health Services Division PS:jb(2122F) cc:Gerald Schwartz, M.D. , Director of Health; 57 Union St. ; Rockville, 06066 Robert Deptula , R.S. , Chief Sanitarian; Torn Hall ; South Windsor, 06074 Century Pool Corp. ; Don Kulowski ; 260 Fairview Ave. ; New Britain, 06051 Building Official; 1540 Sullivan Avenue; S. Windsor, 06074 Page 2 of 2