Loading...
HomeMy WebLinkAbout28 Amato Drive (12)STATE OF CONNECTICUT DEPARTMENT OF HEALT H SERVICES ro.Wr CERTIFICATE OF APPROVAL FOR USE APPROVAL OF SWIMMING POOL RENOVATION PLANS AND SPECIFICATIONS FOR WESTAGE CONDOMINIUMS AMATO DRIVE SOUTH WINDSOR, CT 06074 Thomas J. Martin, Manager Westage Condominiums Association P.O. Box 789 South Windsor, CT 06074 Dear Mr. Martin: The State Department of Health Services is in receipt of an application together with plans and specifications requesting approval of plans for the renovation of an existing, unapproved, indoor swimming pool located at Westage Condominiums. This pool was initially constructed without the required departmental approval. The proposed swimming pool renovation is to be kidnev shaped, have a water capacity of 16,250 gallons, have a water surface area of 460 square feet, and be provided with high rate sand filtration and hypochlorination equipment. A review of the plans and specifications indicates that a "Certificate of Approval for Use" may be issue in accordance with the Public Health Code Section 19-13-B33b(b)l for this swimming pool with the proposed renovations. Therefore, the application is hereby approved by the Commissioner of Health Services subject to the following provisions. The swimming pool and appurtenances are to be renovated in accordance with the details thereof as shown on such approved plans as submitted and as outlined in the summary specifications form attached to this letter. Upon completion of the subject swimming pool renovation a STATEMENT OF CONFORMANCE shall be signed by the pool construction supervisor and an official of the pool construction firm. The signed statement shall be forwarded to the State Department of Health Services prior to use of the swimming pool or obtaining a certificate of occupancy from local municipal officials. Adequate pool maintenance shall be provided in accordance with Section 19-13-B33b of the Public Health Code to secure good operation. If necessary in the future, changes in operational procedure and/or equipment shall be made to produce satisfactory conditions. Written authorization shall be obtained from the State Department of Health Services for any construction or installation of equipment not shown on the plans or stated in the specifications. Page 1 of 2 Phone: 150 Washington Street — Hartford, Connecticut 06106 An Equal Opportunity Employer 566-1259 CERTIFICATE OF APPROVAL FOR USE APPROVAL OF SWIMMING POOL RENOVATION PLANS AND SPECIFICATIONS FOR WESTAGE CONDOMINIUMS The subject swimming pool prior to opening shall be provided with a minimum of one unit of safety equipment for each one-hundred running feet of perimeter of the pool consisting of the following: A ring buoy not more than fifteen inches inside diameter to which shall be attached a fifty-foot length of one-quarter inch line and a shepherd's crook or reach pole with blunted ends, a minimum of twelve feet in length, such poles to be mounted in permanent sockets on opposite sides toward the deep area of the pool. A first aid kit American National Red Cross standard 24 unit kit or the equivalent) shall be provided and kept stocked and ready for use. A telephone which is readily available for emergency use shall be provided on the premises. The operating instructions and isometric diagram of the pool equipment shall be mounted at a location in the filter room which is readily accessible for reading and is well illuminated. These instructions and diagram shall be mounted in a durable manner so as to resist damage from normal conditions in the filter room. No diving equipment or diving facilities shall be installed or erected at the pool, nor shall diving into the pool be permitted. No construction shall be undertaken until the connection to the sanitary sewer is approved by the sewer authoritv. Very truly yours, tI Lc- e Goke M.P.K. , Acting Chief Sanitarian Environmental Health Section Environmental Health Services Division PS/cw(6774C) cc: Director of Health - South Windsor Building Official - South Windsor Splash Pool Supply, 637 John Fitch Blvd. (rte. 5), South Windsor, CT 06074 DEVIATIONS FROM DESIGN CRITERIA 1. Top step 3 feet in width; 4 feet required. 2. Top step riser height is 12 inches: 10 inch maximum is required. Page 2 of 2