HomeMy WebLinkAbout28 Amato Drive (21)FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: NO. q6 70 ) TOWN OF SOUTH WINDSOR EST.COS BLDG. PERMIT NO. VH 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $1,000 - $10.00 1000 or fraction LOCATION OF BUILDING C 4/(O //Cx1_5 I'IRTc7 } thereof - $10.00 e 514'<f, OWNER / a ADDRES TOWN PHONE NO. l HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): Gc-C ,5-a,2 TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the/perform nce of such work. FURTHER DESCRIPTION OF WORK: f. 17 o SS S STATE LICENSE - NAME & TYPE #DATE SI ATURE F APPLICANT APPROVED tATE I as B - R CALCULATION SHEET 1503 (Modern Method)Copyright 1977 by The Hydronks Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM-_-- S p H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.l" U BTUH per Pool of 3 LENGTH EXPOSED WALLS,FT. Radiation Selected a WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION Table 9,Line 3 x MI ROOM LIN.FT.OFTOTALSRADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for L in•5) 7 CEILINGCONSTRUCTION C IT able 9.L a W) O—g FLOOR CONSTRUCTIONt Table 9, L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9,L a H) G 10 c 1 Well(With Openings)G 2 Wells IWoth Openings) DX 3 Wells IWrlh Openings)or Ent.Hen le-J 1 11 TOTAL 11iUl1 AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K L C L.A — --__ _—_ COL.S COL.H COL. I COL_J COL.K COL.L TOTAL BTUH T TAL 1 ROOM OF SUILDINO RADIATION E AT SELECTED p H L W H L W H L W H L W H L W DESIGN TEMP.- 2 ROOM DIMENSI NS. FT F' DIFFERENCE U 3 LENGTH EXPOSED WALLS. FT t e WINDOW AND OUTSIDE DOOR AREA i` BTUH BTUH BTUH BTU" BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM ITable 9, LIns 3 or HI TOTAL 207< 6 TYPE OF GLASS Iedltom of table used for Lone 51 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON Table 9. L or W) GROUND OR FILL AT GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9, L x War Lin Fs) 9 COLD PARTITION CONSTRUCTION ITable 9,L a H) 10 c I Wall(With Openings)O 2 Wells(With ODen.ngsl ex 3 Wells(With O •nm9s1 or Ent Man e J - tDf. 11 107AL BTUH AT 7OF TEMP DIFFERENCE* 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This loan Is awdebo•from The Hydronlcs institute 36 Russo Place.Berkeley M•IphH,N J 07922 FORM 1503 NOV 15 '94 10:45 AERCON CORP.203 271 2067 P. APPLICATION NOTE# 10 WORKSHEET POOL DEHUMIDIFICATION LOAD CALCULATION D COMPANY: PHONE: 'j Qc6 - a ) ADDRESS: FAX: Sc 6 w 6 37 CITY/STATE: JOB NAME: REP. NO. POOL TYPE: X RESIDENTIAL PHONE CONF. ON OPgRATHM DATA POOL SIZE: X SO. FT. SPA SIZE: X" SQ. FT. I VOLTAC3E1ti POOL WATER TEMP: 2ZL F SPA WATER TEMP: Q'N'L 'F AIR TEMP: F DESIGN RH: ACTIVITY FACTOR*: 1 + (Hpurs of Operation + 24) • JR TABLES IN APPLICATION NOTE POOL EVAP. RATE: LWSQ. FT./HR TABLE 3) SPA EVAP. RATE: ...,r„_ LS/SO. FT./HR TABLE 3) SIZING CALCULATIONS POOL LOAD • POOL SO. FT. X POOL EVAP RATE X ACTIVITY FACTOR* x x 6- 1. gio SPA LOAD SPA$0. FT. X SPA EVAPORATION RATE x TOTAL LOAD (SUM OF ABOVE) LB/HR Aotk*factor not hm then 1.25 71 NOV 15 194 10:45 AERCON CORP.203 271 2067 P.3 n SPECIFIC VIONS OV 2=10V 46o vElectrical1PH3PH3PM Compressor FLA 34.3 41.4 0.4 Compressor LRA 142 130 65 Unit FLA 41.3 25.0 1114 M IM' R I/4' Mir else 60 40 20 Minn,Circuit 48,4 99.6 19.6 Unit Fu11 Loed KW 499 6,99 6.99 Unit rati KW 5.11 6.11 6.11 Re OrantorCher/w............ ibe. rw ve Unit Net Beat Capacity(B7'UMR),«...47pW* 2318 it a' Wermel Made Pressure(1±u•Hv0 OW Compressor HP....«.............r....,...«.......8 Blower HP.«......«.........«.........................«.«,.l blower SEre, ..«.«..«....«...«.«.«.......«...13 Ship"Weight(lbs).......«.....................«..678 Condensate Drain.....................................11 M/P.T. Air Inlet,MH..................................«...4011 x 22 OW Air Outbt,WkM...............................««.«1e'n^116° 40' Water Irdet O.D............"........... «.««««..11/r u • Water Outlet O.D......«.»,............................ li/rwv.• War flow(GW•....«...............................«9 Pressure DM(FT-W *«nr«M. .................. 68med oa sir 8>f°i<'D1,M A.H.and nW 4". PERFORMANCE WC-500 (Rehe ode) LAP. IN I AMMIATIRRMUITY i 40% 1 601E 609E 709E 80% W% 450 Lbs IHr(2) 1) 1 1 1 3.1 711 Ou tt Air Lal.'IF' 1 11 1 1 52.9•L4 • Lbe/Hr 2 1 4.9 9.0 11A 17 Out*Air Temp.•R 1 1) 63.50 68.40 67.06 69.20 Lbs/Hr(2) 1) 9,4 14.6 21.8 2713 82.8 Outlet Air LOSE aF 75.61 77.94 80,8• 83.3• 78° fps/Hr(2) 12.1 20.4 204 32.4 89,9 42.3 Outlet Air Tamp.OF 88.8°90.2°93.41 96.10 08.80 100.90 OW W Air Temp.OF 101,01, 103.40 Lbs/Hr(2) 19.1 26.0 32.4 37.4 43.5 48.8 Outlet Air Temp.°P 100.90 104.54 101.3• 100.34 112•114,7• q5° Lbs/Hr 121 2412 32.0 4_04 1 1 1 Outlet Air Temp.OF 113.90 117.6• 1 121.41•1) 1) 1) The above performance.dato Is to.serve as a guide for plectlon of the appropriate dehuntlditler.Actual performance is a function of theoperatingandit'ntallabon conditions. 1)Contact Desert Aire i 2)Amadrig 1030 Mb Moisture EXPECT THE BEST FROM . , .:DESERT AIRED 8300 W.glefkr Coact Milwaukee,wi 53223 414)357.7400 FAX(414)357.MOZ r NOV 16 '94 02:04PM THIBODEAU MANAGEMENT P. 1 2W.IBODEAU MANAGEMENT SERVICES, INC. 1050 SUI.LIVAN AVENUE SOUTH WINDSOR, CT 06074 TELEPHONE 644-1571 FAX 644.67I0 TELECOPY COVER LE DATE.- NUMBER OF PAGES FOLLOWING:1 TELECOPY NUMBER. FROM. Ifyou do not receive all of the pages or ifany part is illegible, please call us at the above stored numbers. Thank You NOV 16 '94 02:04PM THIBODEAU MANAGEMENT P.2 Westview Office Park Condominium thibadeau 1050 Sullivan Avenue South Windsor.Connecticut 06074 L'--Wmanagement S - -md 1-800-92929-3323328 Services, inc. Fax(203)644-6710 November 16, 1994 Town of South Windsor Building Department Attn: John Collins Dear John, The Wastage Condominium Association Board of Directors has hired Bilco Heaing and Cooling to install the Desert Aire Dehumidification System in their clubhouse in accordance with th recommendations of the association's engineer, Tim Wentzell, of Connecticut property Engineering. If you have any questions, please call me at 644-1571. Sincerely, A!51c:: C,t Steve Cabaniss Property Manager for Wastage Condominium CCMNLIMTY