Loading...
HomeMy WebLinkAbout28 Amato Drive (23)FOR OFFICE_ USE ONLY APPLICATION FOR HVAC PERMIT DATE: 9 31- 9 1-5-' N0. _,9iL TOWN OF SOUTH WINDSOR EST.COST: 8, 9oo•ov BLDG. PERMIT NO. p,A 1540 SULLIVAN AVENUE FEE egD.Da SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $1,000 - $10.00 1000 or fraction LOCATION OF BUILDING /U iaySc Aj a fo thereof - $10.00 ltic ifss A OWNERY ADDRESS TOWN PHONE NO. s' 5 r 7 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC_e, WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): `'- l J/ /17-LO- ,e S78luf GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE F INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME & TYPE #DATE SIGNATURE OF APPIOTCANT 13 U 3 3 ( APPROVED DATE I - B - R CALCULATION SHEET 1603 (Modern Method)Copyright 1971 by The Hydronkr Institute OWNER ADDRESS OESION TEMPERATURE DIFFERENCE F. DATE COL.A COL.6 COL.C COL.D COL.E COL.F COL.G I ROOM IXp H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.U STUN per Fool of 3 LENGTH EXPOSED WALLS,FT. l Radiation Selected a WINDOW AND OUTSIDE DOOR AREA Is. STUN STUN STUN STUN STUN S WALL CONSTRUCTION ROOM LI FT.OF Table 9,Line 3 is H) TOTALS RADIATIONIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED IBottom of table used for Line SI 1Z 7 CEILING CONSTRUCTION C Table 9. L W) g FLOORCONSTRUCTIONII O- Table 9, L r W of Lin. F t l E 9 COLD PARTITION CONSTRUCTION F Table 9, L it HI G 10 C 1 Wail I W Ith Openinge)G; H c 2 Walls(With Openings) DX e J I3Watts1WrihOpenings)or Ent.Hall I- I 1 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 17 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K C L.A - -_ -_ COLS COL.H COL.1 COL_1 COL. K COL.L TOTAL BTUH TOTAL OF SUILDINO RADIATION1ROOM E AT SELECTED O H L I W H I L W H L W H L W H L W DESIONTEMP.• 2 ROOM DIMENSI NS. FT f' DIFFERENCE U 3 LENGTH EXPOSED WALLS. FT 4 WINDOW AND OUTSIDE DOOR AREA LL STUN BTUH BTU" STUN BTUH S WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 w HI TOTAL 20% 6 TYPE OF GLASS IBottom of table used for Line 5) 7 CEILING CONSTRUCTION IFOR CONCRETE FLOOR ON AT Table 9, L a W) GROUND FILL GRADE LEVEL,USE LINEAR 9 FLOOR CONSTRUCTIONS FEET OF EXPOSED EDGE ITablo9. LaWorLin Ft) 9 COLD PARTITI N CONSTRUCTION I Table P. L H) 10 c 1 Wall(With Opaningsl O Z 2 Wells(Wrlh Open,ngsi 2 X 3 Wells(With Openings) or Ent Hall I I TOTAL BTUH AT 7OF TEMP DIFFERENCE* 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503ThisformIswarlobiefromTheHydroolceinstitute.36 Russo Place,Berkeley Heights,N J 07922 INSPECTOR J DATE TIME LOCATION 1451, INSPECTION: CODE: RESULT(R/A) : BUILDING: ELECTRICAL: PLUMBING: HVAC: OTHER: PLUMBING: HVAC: OTHER: