HomeMy WebLinkAbout1974 - 1708 Ellington Road - Septic ApplicationsTOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
South Windsor, Connecticut
Application for Permit to Install or Repair Individual Sewage Disposal System
Application No. _
TO THE BUILDING DEPARTMENT: Date 8'30-74 19
A permit is requested for repair or construction of an individual sewage disposal system concerning which the
following information is submitted:
1. Owner of PropertyRobert Kre""- _Address of Owner== 7 t. :: '• • _7 _
2. Location of Property 1708 Ellixirt®x road South Wi xdsor , C&Ax --Lot. No.
3. Type of Structure Commercial No. of Bedrooms_ _
( Dwelling, Commercial Building, Store, etc.)
4. Number of Families or Persons to Occupy Premises_ N/A
5. Plumbing Fixtures: Water Closets Urinals Lavatories Bathtubs
Showers _ Kitchen Sinks Laundry Tubs — Garbage Grinder — Other
6. Liquid Capacity of Septic Tank 2,000 Gal. Material of Septic Tank ('Lr r t,%
7. Soil Conditions: Type of Soil ClAy _ Maximum ground water table__
(Sand, Gravel, Clay, etc.)
8. If not served by public water supply: Distance from Owner's well from adjacent wells
9. Distance to nearest water course, drainage ditch, storm drain or embankment
10. Percolation Tests: Time for 1" drop in soil test No Leechilr• Classification of soil
11. Minimum square feet of effective seepage area required _
12. Leaching System: Number of trenches 2 Length Width S ' Total 750' sQ. f t .
n t1
Other 2 trenches cextaixixg ax 18 Bed of Z Crushed stoxe covered with 18 of said
per exg. desigx. approved'by Melvix Edwards
Signature _
( Licensed Installer)
(Sketch showing all minimum distances and other details required below)
Permit Issued— 19 By
Installation Completed, Inspected and Approved 19 By
17
,1,31
0oturt of Ovut4 Mubsor
Department of Pollution Control
SOUTH WINDSOR, CONNECTICUT
DRAIN LAYER'S PERMIT
Application for Permit to Install or Repair Individual Sewage Disposal System
To Sewer I]e t. Permit No. Fee Paid ...r.................. B.................................... P
Date...8.-.30.-74...............................................
Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein
for repair ......,.. or construction ......... of an individual sewage disposal system concerning which the following
information is submitted:
1. Owner of Property ..JR* ems, �r peg at... ...:..:...:................................ Address of Owner .....1..7..Q..8 Z11i)t9t9X... Rq..ad ........................
2. Location of Property .,,.. E1�ax tmx...Rd. _S®. Winds®r .............. Lot No.
C�mmcrcial
3. Type of Structure............................................................. _............................ ................. ......................._...................
.............
(Dwelling, Commercial Building, Store, etc.)
4. Number of Families or Persons to Occupy Premises :........... ..Y/A............... ,.... ............................... .,...,.........................,.._.........,............. ..................
5. Number of Bedrooms N/A
6. Average Daily Flow ........220....E ...............
Manufacturer and
7. Liquid Capacity of Septic Tank 2000 Material of Septic Tank Concrete
......... - ------�--.........._...................................................w
8. Soil Conditions: Type of Soil .... ....�....................
(Sand, Gravel, Clay, etc.)
Maximumground water table .................,,.,............._................................. .w....»...................... ............................................
9. If not served by public water supply:
Distance from Owner's well.......................................................................
From adjacent wells -- .............. ...... _............ ... ..........................
........,.....
10. Distance to nearest water course, drainage ditch, storm drain or embankment............:...........::M:.:...., M:. »..,....,, - ............. ..... ..
11. Percolation Tests: Time for 1,. drop insoil test Ne I,eachixs.................. ............ ........... _.......:._ ..............................
Classification of soil ....... ... ..... ..... ....... ............._................. ........................................................................................... .... .......
:..
12. Minimum square feet of effective seepage area required (50--.$ , ft.._.--- .............................. ......,.......
13. Leaching System: Number of trenches 2......._.._._.......... . Length 2 .................... .„ .Width ..... .... ................. ......... _............
Total...................................... Other ... ................. .................... .............................. ................,......... ........... .........
14. Plot Plan Attached..........9e............................................
15. Layout Approved. ....per...e 4�!�Pi.gx ..........
aprov ved M. EDwards
16. This permit expires..............................................................................................................
Signature..................... .......................... ..................................... ..................„........................ ............. „, ........„ ,
(Licensed Drain Layer)
Installation Completed, Inspected and Approved in accordance with State Public Health Code and Local Ordinances
............................................ 19.................. By . ....................... ......... ......... .._................. ......................................................... ..................
PollutionProblem abated Date.........................................................................................................................................................w...............
Inspector
MEMORANDUM
TO: Terry V. Sprenkel, Town Manager
FROM: Alice J. Turek, M.D.
DATE: Sept. 6, 1974
SUBJECT: Sec. 19-13-B20c, and Sec. 19-13-B20m, Public Health Code
This is to call your attention to the above sections of the Public
Health Code (copies of which are attached) providing that all oversized
sub -surface sewage disposal systems, and systems in soil with a slow
seepage rate must have plans submitted to the State Health Department
prior to approval by the Director of Health.
Until approval of the State Department of Health has been obtained,
construction of Mr. Krepcio's office building at Ellington Road will
have to be delayed.
attach.
cc: W. Grace, P&Z
J. Page, P&Z
E. Lucek,aPublic Works Dir.
M. Edwards, Pollution Control C
D. McLaughlin, Building Inspector
06/17/20C.5 FRI 11:05 FAX 860 644 7280 South Windsor Town Hall 0001
*********************
*** FAX TX REPORT ***
*********************
TRANSMISSION OK
JOB NO.
4404
DESTINATION ADDRESS
92822684
PSWD/SUBADDRESS
DESTINATION ID
ST. TIME
06/17 11:04
USAGE T
00' 37
PGS.
1
RESULT
OK
{
l-1 00 I
4
n.,,.,.
Gown of fotd4 Witbour
Department of Pollution Control
SOUTH WINDSOR, CONNECTICUT
DRAIN LAYER'S PERMIT
Application for Permit to Install or epa' Individual Sewage Disposal System
C 3
Fee Paid $ By Permit No. �`..... ". ✓ ,.�......... .. / ......
Datletb .4 ................ � -- .........
Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein
for repair . or construction of an individual sewage disposal system concerning which the following
information is submitted:
1. Owner of Property .. ............................. ..._........................-.-.
2. Location of Property...�7d%-g-.--..-4.�,..............{�-....,..,.~-....-.............�-..._...........��.......-........_.-..,....................,...._
,r�
Address of O►y er.....:........... .................... ...._.....,............ ........... ...... _...............
`' Lot No. ..............................
3. Type of Structure .............�.........................................................
...-..-...........
.................... ............ .-... -...........w�...._..................................... ............... ......................
(Dwelling,
Comnierc Lil Budding, Store, etc.)
4. Number of Families or Persons to Occupy Premises.........
... ............................................................. .... .:................ ......... , .„::... .
5. Number of Bedrooms ................................................
6. Average Daily Flow ..................................................
7. Liquid Capacity of Septic Tank .
Manufacturer and
Material of Septic Tank ... ....... ....... ................................ ....... ................ .......
8. Soil Conditions: Type of Soil ... .....-.-.
........... .
(Sand, Gravel, Clay, etc.)
Maximum ground water table .._......._...:.............::....:..........:.............,,.........,...,.........:..........:,..,..:......
9. If not served by public water supply:
Distance from Owner's well ..................
From adjacent wells .. ......................
10. Distance to nearest water course, drainage ditch, storm drain or embankment......................................................................................
11. Percolation Tests: Time for 1" drop in soil test.............................................................................................::....:....._............ .............. .......... ......... .....
Classificationof soil ................. . .............. ......-.-...-......--........... ....... ....... ............ .......................................... ...................... w......M.......... ....
12. Minimum square feet of effective seepage area required .+....w.............. r........_ _.............
13. Leaching System: Number of trenches .... _ ......................................... . Length ....--- ................................ ..... ... Width -- --- ..------ ......... .. .
Total ................... Other ........... ^ � '.'..................... ........:..:::........:....:....:.............
....
14. Plot Plan Attached. ..... ' ' 'A'r ,
15. Layout Approved. ....................................... F r
--
16. This permit expires .. .... ....... .............. ....... :...::......w............... ....,...-........ ...............................
Signature........................ .. .. ............................................................................
(Licensed Drain Layer)
Installation Completed, Inspected and Approved in accordance with State Public Health Code and Local Ordinances
........................................................... 19 .................. By ........... ........................................................ .................. ......... _.:,...:.................................
PollutionProblem abated Date..........................................................................w.,..._.....-...............,............. ..................,.... .................
Inspector
FR AN C I S V. R O S S I, P. E. CONSULTING ENGINEER
1209 John Fitch Boulevard • South Windsor, Connecticut 06074 • Tel, (203) 204329
27 August 1974
Mr. Mel Edwards, Town Sanitarian
Town of South Windsor
Town Hall
South Wind -'or, Conn.
Re: Proposed Sewer System for Robert Krepcio
1708 Ellington Road, South Windsor, CT
Dear Sir:
A percolation test was taken on the above referenced property
on August 2, 1974. The results indicated almost no leaching in the
clay soil encountered.
The building under construction will contain the "Spell of Beauty
Salon" presently operating on Sullivan Ave., South Windsor. The water
use was checked with Connecticut Water Company and has remained approxi-
mately 20,000 gal. per quarter of a year, which equals approximately
220 gal. per day.
The proposed system consists of a 2,000 gal. pre -cast concrete
septic tank and a leaching field 20 ft. x 100 ft. with 150 L.F. of
4" perf. pipe. The field will be constructed with 18" of 1" broken
stone below the pipe and 18" of sand backfill over the pipe with a
stand of grass planted over the field.
This will provide a minimum of over one week storage in the tank.
It is anticipated that the tank will be pumped out a maximum of one
week intervals in the worst condition and the pumping may be extended
to 3 or 4 week intervals in the warm weather.
This is naturally only a short term interim solution and it is
anticipated that a connection to the municipal sewer system will be
made as soon as it is available, the owner anticipates this possibly
in less than one year, depending on the town sewer program.
FVR:bj
Very truly/; ? yours,
�. f!! //A''
Francis V. Rossi P.E.
�� i r
UY r
V ,-
pl
AorO r,
Au�,44
CA L C7 La
sv i A/0 JO
ot 11 00 C) 10A A K,
f 0
2 0 00
0
Am 4f. I. F p 6
71
,7/ NN%Nt
SEP 161974
CONNECTICUT STATE DEPARTMENT OF HEALTH
56o'-3llo
Alice J Turek, M.D.
Acting Director of Health of South Windsor
1540 Sullivan Avenue
South Windsor, Connecticut 06074
Dear Doctor Tuzek:
We have reviewed plans for a subsurface se
building owned by Mr. Hobert J. Krepcio at
plans were prepared by Francis V. Rossi,
office pursuant to Section 19-13-B20m of
This is an existing building wtit
contain a beauty shop initiallquestionable as to when thesefor sewage disposal purposes.future. This hays been the South Windsor Sew mctis
within one or at most,.- o years
September 16, 1974
sal aya�for a commercial
on R South Windsor. These
tin gineer, and submitted to this
a' eg0?_q Code.
L*naled. It is expected that it will
k a]. . N't pro offices upstairs, but it is
ed.he soil on this property is poor
c sewers are expected in the near
by Air. Janes H. Throwe, Ci:airman. of
expected that sewers will be available
The volume of sewage a ten the beauty shop is quite low. Metered water con-
sumption from the estab which is presently located on Sullivan avenue, has
shown usage of approximately 220 gallons per day. The engineer proposes to
icstall a 2;,000-gal1on septic tank and a leeching bed 20 feet wide :uid i00 feet
long. Tbi-s would provide about 6W square feet of effective leaching a , and
the appl3.cation rate to the soil would be about .3 gallona per square foot par
day, whicia is very low.
We feel that the plans are satisfactory and shulci "-approved. However, we would
suggest one slight modification in the construction details. It is recommended
that the bottom of the bed be placed only about 18 inches into the existing grade,
and the 18 inches of sand covering the system be mounded up above the original
grade. This should further promote eva ooxstJ ora from the: system and crake most ef-
ficient utilization of the upper portions of the existing soil which are probably
more permeable. The plan should be approved for temporary use only until public
severs are available. It mig�Lt be desirable to make the approval valid for one
year only subject to review at that time. If the system is functioning properly,
the approval could be extended. If any problem did occur, the owner could be re-
quired to pump out the system regularly until the sewer was available.
If you have any questions, please contact us.
Sincerely yours,
Theodore C. Willerford
TCW/pdp ,aA Principal Sanitary D3gineer
cc: 'JT 4 a0m m, Bldg Insp
R. Krepcio, 150 Berle Rd., S.Windsor
November 7, 1975
Mr. David C. Wiggins Director
Environmental Health Services
Connecticut State Department of Health
79 Elm Street
Hartford, CT 06115
Bear Mr. Wiggin:
The South Windsor Sewer Commission has voted to approve the extension
of the temporary permit for Robert Nrepcio on property he owns at
1708 Mington Road, South Windsor. There have been no problems in the
operation of the septic system and the owner has complied with all the
requirements of the Town Department of Pollution Control. Moreover, a
proposed sewer extension has been approved by the voters for bonding
and construction will begin late in 1976 with the final completion in
1977 or 1978. While it is not known when the project covering Ellington
Road will begin, it will be within the aboveamentioned time frame.
Accordingly, an extension should be granted to Mr. Hrepcio for his pro-
perty.
Very truly yours,
James R. Throve
- Chairman
SUTH WINDSOR SEWER COMMISSION
JWT/brs
CC: Mr. Robert Krespelo
150 Berle Road
South Windsor, CT 06074
L'Mr. Melvin Edwards, Jr., Superintendent
Department of Pollution Control
Town of South Windsor