HomeMy WebLinkAbout2013-5-30 - 1708 Ellington Road - Environmental Notice LetterConnecticut Department of
ENERGY & 1r�30<0/
ENVISo
P R ORTOE C T NO N May 28 2013��r, NMETAL
�Fp7.
79 Elm Street • Hartford, CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal Opportunity Employer
NOTICE OF SIGNIFICANT ENVIRONMENTAL HAZARD REPORT
The Honorable Thomas A. Delnicki
Mayor
Town of South Windsor
1540 Sullivan Avenue
South Windsor, CT 06074
Dear Mayor Delnicki:
Section 22a-6u of the Connecticut General Statutes requires the Connecticut Department of Energy and
Environmental Protection (DEEP) to provide you with notice of a significant environmental hazard
reported in your jurisdiction. Under the statute, DEEP is also notifying the state representative and state
senator representing the area in which the pollution has been identified. DEEP must, in addition, provide
notification to Federal and State Occupational Safety and Health Administration (OSHA) offices that
have jurisdiction, and is required to post on the Department's Internet website a listing of all notices
received under this law. Additional information about the reporting of significant environmental hazards
to DEEP is available in a DEEP fact sheet that can be found in the Remediation section of the DEEP
internet site at littp://www.ct.gov/dep/remediatioli.
Enclosed please find a copy of a Significant Environmental Hazard Report for 1708 Ellington Road in
South Windsor. The significant environmental hazard reported is that pollution detected in groundwater
above standards may threaten a drinking water well. Also enclosed is a copy of the DEEP's
acknowledgement letter in response to this hazard notification. Threatened drinking water supply wells
have been sampled multiple times and contain no contaminants of concern. In the acknowledgement
letter DEEP directed the property owner to contiue to monitor onsite groundwater condition and submitt
annual reports.
If you have any questions, or for further information regarding the Department's response or actions
under this program, please contact Rob Robinson of DEEP at (860) 424-3775.
Sincerely,
Patrick F. Bowe
Director
Remediation Division
Bureau of Water Protection and Land Reuse
Enclosures
PFB:kan
i
cc : Mr. Matthew B. Galligan, Town Manager, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
Dr. Gerald L. Schwartz, Director of Health, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
Connecticut Department of
ENERGY &
ENVIRONMENTAL
PROTECTION Mav 28, 2013
79 Elm Street • Hartford, CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal Opportunity Employer
ACKNOWLEDGEMENT
Mr. Gary Spelucim
10 Grace Lane
Portland, CT 06480
RE; Notification of Significant Environmental Hazard
Spelucin Property
1708 Ellington Road, South Windsor
Dear Mr. Spelucim:
This is to acknowledge receipt, on May 13, 2013 of written notification, under the requirements
of Connecticut General Statutes (CGS) Section 22a-6u. This notification reported the presence of
an environmental hazard at a property owned by you, located at 1708 Ellington Road in South
Windsor. The notification identified the following significant environmental hazard(s):
Groundwater polluted with Benzene at a concentration of 510 ug/L, exceeding the
adopted groundwater protection criteria, is or may be located within 500 feet upgradient
of a supply well.
Thank you for notifying the Department of Energy and Environmental Protection (DEEP) of this
condition, which you believe is due to an underground storage tank leak. It is DEEP's
understanding that in the intervening period downgradient drinking water wells were sampled and
were determined to be non -detect for the contaminant of concern.
DEEP requests, under CGS Section 22a-6u (k)(1), that you continue to monitor onsite
groundwater concentration for the contaminants of concern and submitt annual reports to the
attention of the staff member below. If groundwater conditions change, please collect additional
samples for the downgradient drinking water supply wells.
Pursuant to CGS Section 22a-6u(i), the owner of the water supply well tested, the local Health
Director, and the identified DEEP staff member must be notified in writing within 24 hours of
receipt of any analytical results indicating that a water supply well sample exceeds action levels
or maximum contaminant levels. In addition, DEEP requests that such notifications also inform
well owners of their statutory obligations under Section 22a-6u(i). Furthermore, if potable
drinking water wells become impacted with the contaminant of concern, actions need to be taken
to provide an immediate alternative supply of potable water and recommendations for continued
provision of potable water.
Except for environmental hazards identified under CGS 22a-6u Section (b)(1) or (h)(1), further
notifications resulting from investigations conducted as a result of this acknowledgement are not
necessary, provided that DEEP is promptly advised of sample results as requested above. Should
you wish to voluntarily remediate this site, several programs are available under Sections 22a-
133x and 22a-133y of the Connecticut General Statutes.
Page 1 of 2
For your information, pursuant to the requirements of CGS Section 22a-6u (m), the DEEP must
forward a copy of your written notification to the chief elected official of the municipality in
which the site is located, the state senator and state representative for the site's location, and state
and federal Occupational Safety and Health officials. DEEP also sends a copy to the Local
Health Director. In addition, DEEP sends a copy of this acknowledgement letter to these
individuals. The DEEP must also add this site to the "List of Significant Environmental Hazards
Reported to the DEEP" that is maintained on the DEEP internet site. Also, be advised that CGS
Section 22a-6u (1), requires that the Significant Environmental Hazard Notification Report be
conspicuously posted at the site not later than five days after the commencement of an activity by
any person that increases the likelihood of human exposure to known contaminants.
If you have any questions regarding your obligations specified in this letter, please contact Kevin
Neary of the DEEP at 860-424-3947.
Sincerely,. '
Il — --
Patrick F. Bowe
Director
Remediation Division
Bureau of Water Protection and Land Reuse
PFB:kan
CERTIFIED MAIL RRR
cc: Mr. Joseph Santovasi, Advanced Environmental Interface, Inc. (AEI), 8 Old Indian Trail, Middletown, CT 06455
Kevin Neary, DEEP
Kenneth Feathers, DEEP
As noted above, under the provisions of CGSSection 22a-6u (m) copies are also provided to the following:
Dr. Gerald L. Schwartz, Director of Health, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
Mr. Matthew B. Galligan, Town Manager, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
The Honorable Thomas A. Delnicki, Mayor, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
The Honorable William Aman, State Representative, Legislative Office Building, Room 2105, Hartford, CT 06106-1591
The Honorable Gary D. LeBeau, State Senator, State Capitol, Room C-417, Hartford, CT 06106-1591
Connecticut Department of Labor, Division of Occupational Safety & Health, 38 Wolcott Hill Rd, Wethersfield, CT 06109
Mr. Bill Freeman, Area Director, OSHA, 450 Main Street, Room 613, Hartford, CT 06103
HazNotMrg_Ackn.dot Page 2 of 2
Connecticut Department of
Energy & Environmental Protection
Bureau of Water Protection & Land Reuse
Remediation Division
Notification under CGS 22a-6u
Please print or type to complete this form in accordance with
the instructions (DEEP-REM-SEH-INS-500).
Send completed report to:
SIGNIFICANT ENVIRONMENTAL HAZARD PROGRAM
REMEDIATION DIVISION
BUREAU OF WATER PROTECTION AND LAND REUSE
DEPARTMENT OF ENERGY AND ENVIRONMENTAL
PROTECTION
79 ELM STREET
HARTFORD, CT 06106-5127
Check box if addendum pages used:
Significant
Environmental
Hazard
Notification
WATER PROTECTION AND LEND REUSE
PEMEDIATION DNISION
MAY I
SITE NAIJIE _ q 1,,,Z,'
ADDRESS
TOWN
FILE TYPE _...--_—`- "--- -__...----------
DEEP USE ONLY
RemCIS -'f065 RemlD 11 `0- SEH# r
Hazard Condition(s) Identified: [CGS Section 22a-6u subsection]
❑ Explosion threat [6u-(h)] Conditions Threatening Public or Private/Residential
Drinking Water Supply Wells:
❑ Volatile Organic Chemicals in groundwater ❑ Contamination is detected in supply well and is
threaten interior air quality [6u-(e)] above groundwater protection criteria [6u-(b)]
❑ Surface water quality threatened by ❑ Contamination is detected in supply well but is
groundwater contamination [6u-(f)] below groundwater protection criteria [6u-(c)]
❑ Surface soil contamination poses potential ® Groundwater above groundwater protection
direct exposure risk [6u-(d)] criteria threatens supply well within 500 ft [6u-(g)]
Part I - Site Information
Site identification for parcel with pollution, on or emanating from the parcel, causing a
significant environmental hazard
Name of Site
Spelucin Property
Address or Location 1 1708 Ellington Road
1 City/Town I South Windsor I State I CT I Zip Code 106074
2. Attach a copy of a topographic map with the site located thereon. Map Attached
3. Business/person submitting form: Is this entitv/person the site's owner? YES ® NO ❑
Name
Gary C. Spelucin
Mailing Address
10 Grace Lane
City/Town
Portland
State
CT
Zip Code 06480
Business Phone
860-342-1581
Ext.
Fax
Authorized Rep.
Same
Title
Contact Person
Same
Title
DEEP-REM-SEH-FRM-500
1 of 6
Rev. 1 /17/12
Part I - Site Information (continued)
3. & 4. Supplemental Information. If the person submitting this form is not the site owner, describe that
to the Site ana its owner ana enter the Site owner Inronnation in 44 fsee
4. Owner or Additional Party for site (see instructions):
Name
Gary C. Spelucin
Mailing Address
10 Grace Lane
City/Town
Portland
State
CT
Zip Code
06480
Business Phone
860-342-1581
Ext.
Fax
Contact Person
Same
Title
5. Operator/Tenant at site, if different from owner:
Name/Firm
Same
Mailing Address
City/Town
Business Phone
State
Zip Code
Fax
I
Ext.
Contact Person
Title
6. Technical Environmental Professional (TEP) who identified hazard: CHECK IF NONE
Firm
Advanced Environmental Interface, Inc. (AEI)
Mailing Address
8 Old Indian Trail
City/Town
Middlefield
State
CT
Zip Code
06455
Business Phone
860-349-3559
Ext.
Fax 860-349-2286
Contact Person
Joseph Santovasi
Title
Principal
7. Environmental consultant for abatement, if not above TER
Firm
Mailing Address
City/Town
State
Zip Code
Business Phone
Ext.
Fax
Contact Person
Title
DEEP-REM-SEH-FRM-500 2 of 6 Rev. 1/17/12
Part II - Hazard Summary
1. How was the pollutant released?
❑
unknown
❑
landfill/wastepile
❑
septic system
®
UST leak
❑
spill/dumping
❑
burial
❑
dry well
❑
drums
❑
agricultural activity
❑
pit
❑
lagoon
❑
discharge
2. What is the general nature of the contamination?
®
petroleum/oils
Organic Chemicals
❑
metals
❑
sodium/salt
®
gasoline
®
volatile
❑
semivolatile
❑
cyanide
❑
leachate
®
fuel oil/diesel
®
nonchlorinated
❑
polyaromatic
❑
acid/base
❑
asbestos
❑
nitrate/fertilizer
❑
chlorinated
❑
pesticide/herbicide
❑
PCB
❑
radiation
3. For environmental sampling (soil or monitoring wells), list the analytical data that are the
basis for determining that a hazard condition exists. (See section 7 for supply well data.)
CHECK IF NO ENVIRONMENTAL SAMPLES C01_LECTFD Fl
Media
(Soil/GW)
Sample
Location ID
Pollutant
i
Concentration
i.
Notes
GW
MW-6
Benzene
510 ppb
See attached table & site maps
mate: List omy the nignest concentration for each medium/pollutant causing the hazard conditlon(s).
Attach additional sheets as needed.
4. Attach a site sketch map indicating the specific location of Site Map
the contamination or condition and applicable sampling locations. Attached
5. Was an inventory of drinking water supply wells within 500 feet conducted? YES ® No ❑
6. If so, is this inventory report, including a parcel map of properties
within 500 feet that may be served by wells, included? N/A ❑ YES ® NO ❑
7. Identify affected or threatened drinking water supply wells: N/A ❑ UNKNOWN ❑
For hazard conditions based on suunly well samples, list analvtical data establishing that the condition exists.
No. of
Supply Well analyses (if any)
Address/Town
Contact Name/Phone
people
*Pollutant/Concentration
1676 Ellington Rd., South
Karen Osborne
Windsor
860-291-3712
502.2 results non -detect
1700 Ellington Rd., South
Bob Urso
Windsor
860-268-2452
502.2 results non -detect
1700 Ellington Rd., South
Bob Urso
524.2 results non -detect
Windsor
860-268-2452
* See attached lab reports
wore: Kerer ro wgnmcant tnwronmental Hazard Heport Instructions. Attach additional sheets as needed.
8. Are hydrogeologic data/maps supporting the hazard identification included? YES ® No ❑
DEEP-REM-SEH-FRM-500 3 of 6 Rev. 1/17/12
Part II Hazard Summary (continued)
9. Identify any other affected properties:
Address/Town I Contact Name/Phone
NA
CHECK IF NONE AFFECTED ❑
How is Property Affected?
Attach additional sheets as needed.
10. Describe the land use of the site and surrounding area, and identify any sensitive land uses
within 1/4 mile of the site:
Mix of commercial, retail, and residential uses. Wetlands north and west of the site. Day care facility on abutting
site (1720 Ellington Rd.) to the east and northeast (upgradient).
11. If due to a recent spill. was spill notification made? NOT A SPILL n YES ICI NO n
Date
2002
DEEP contact
M. Williamson
Remarks
12. If due to a UST system release. was DEEP notified? NOT A LIST RELEASE I-1 YES W No li
Date
2002
DEEP contact
M. Williamson
Remarks
13. For drinkina water SUDDIv above criteria and explosion threat hazard conditions only:
Was oral notification to DEEP made? YES ❑ No ❑
Date
DEEP contact
Remarks:
Was verification to TEP client made? N/A ® YES ❑ NO ❑
Date I
Contact
I
Remarks:
i4. maaiuonal comments regaraing the nazara conaiuontsy
On -site contamination is the result of historic UST system releases that occured prior to G. Spelucin purchase of
property in 1984. Circa 1948-1984 property was a gasoline service station and auto repair garage. Mr. Spelucin
converted the property to commercial/office use upon his purchase in 1984. Residual contamination on the site is
limited in extent due to the presence of tight soils (silts and clays), which minimize the potential for migration.
Attach additional sheets as needed.
DEEP-REM-SEH-FRM-500 4 of 6 Rev. 1/17/12
Part III - Past DEP Involvement (OPTIONAL)
1 _ VoluntaE,v Remediation/FCAF/Pronerty Transfer filings -
CHECK IF NONE �I
Form Date CertifyingNerifying/Filing Party DEEP Determination
2. DEEP staff involved with assessment or remediation of the site: CHECK IF NONE F1
Time Period
DEEP Section
Name
M. Williamson
2002
Oil and Chemical
Spills
3. Reoorts to DEEP Emernencv Resnonse and Soill Prevention Division: CHECK IF NONE 1-1
Date
2002
UST Release
or other spill?
UST
Material Released
Quantity
Unknown
Petroleum (historic)
4. Describe other relevant DEEP permitting or enforcement involvement: CHECK IF NONE jJ
EPA ID#: CT I DEEP -WPC #: I DEEP Inventory #:
RCRA Notifier Status.
Remarks:
RCRA Permit Status
5. What environmental renorts exist for the site and are available to DEEP? CHECK IF NONE F-
Report
Type
Date
(mo/yr)
Preparer (Firm)
Attached?
(Y/N)
Previously
submitted?
Y
DEEP Unit to
which sent
Phase 1
4/92
CEES
N
UST Fund
Phase 2
4/92
CEES
N
Y
UST Fund
Phase 3
Phase 2
6/02
ESI
N
Y
UST Fund
UST Fund
3/03
AEI (w/Phase 2+)
N
Y
UST Fund
Attach additional sheets as needed.
DEEP-REM-SEH-FRM-500 5 of 6 Rev. 1/17/12
Part IV - Actions to Abate Hazard CHECK IF PLAN OR REPORT ATTACHED ❑
Describe actions already taken to abate the hazard condition: CHECK IF NONE ❑
Gasoline USTs were removed prior to 1984 by the previous property owner. Heating oil UST and certain related
impacted soils were removed in 2002 by G. Spelucin. Private potable well at 1700 Ellington Rd. was sampled in
June 2002 and April 2013, and found to have no detectable concentrations of VOCs via Method 524.2 and Method
502.2, respectively. Private potable well at 1676 Ellington Rd. was sampled in April 2013, and found to have no
detectable concentrations of VOCs via Method 502.2.
Attach additional sheets as needed
Describe actions to be taken to abate the hazard condition: CHECK IF NONE
Attach additional sheets as needed.
Part V — Signature of Notifying Party
"I have personally examined and am familiar with the information submitted in this document and all
attachments, and certify that based on reasonable investigation the submitted information is true and
accurate to the best of my knowledge and belief. I certify that this form is complete and accurate as
prescribed by the Commissioner without alteration of the text."
Name
Gary C. Spelucin
Title
(print or type)
(if applicable)
Signature
{late
Signifies information required by CGS Section 22a-6u,
DEEP-REM-SEH-FRM-500 6 of 6 Rev. 1/17/12
tL Town of South Windsor, CT
Property Listing Report GIS PIN 30301708 Account 30301708
Property Information
roperty Location
1708 ELLINGTON ROAD
Owner
SPELUCIN GARY C
Co -Owner
Mailing Address
10 GRACE LANE
PORTLAND CT 06480
Land Use
201 Commercial
Land Class
C
Water Service
MDC 860.278.7850
Photo
Primary Construction Details
Year Built
1946
Stories
2.00
Building Style
Office
Building Use
CommlInd
Building Condition
C
Floors
Carpet
Total Rooms
Sewer Service
YES
Census Tract
4874
Neighborhood
0
Zoning Code
RC
Acreage
0.64
Book / Page
6661274
Lot Setting/Desc
Trash Day
MONDAY
Sketch
Bedrooms
0
Full Bathrooms
10
Half Bathrooms
Bath Style
n/a
Kitchen Style
n/a
Roof Style
Flat
Roof Cover
Rolled
Exterior Walls
Wood on Sheath
Interior Walls
Drywall
Heating Type
Hot Water
Heating Fuel
Gas
AC Type
Gross Bldg Area
4320
Total Living Area
4320
Report Created On 5/30/2013
ai Town of South Windsor, CT
Property Listing Report GIS PIN 30301708
Valuation Summary (Assessed value = 70% of Appraised Value)
Item
Appraised
Assessed
Buildings
Outbuildings
Improvements
Extras
Land
Total
0
Sub Areas
Sales History
Owner of Record
Account 30301708
Outbuilding and Extra Items
Book/Page Sale Date Sale Price
SPELUCIN GARY C 6661274 9/2/1992
Report Created On 5/3012013
60
Connecticut Department of
ENERGY &
ENVIRONMENTAL
PROTECTION Mav 28, 2013
79 Elm Street • Hartford, CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal f ppar
NOTICE OF SIGNIFICANT ENVIRONMENTAL HAZARD REPORT
The Honorable Thomas A. Delnicki
Mayor
Town of South Windsor
1540 Sullivan Avenue
South Windsor, CT 06074
Dear Mayor Delnicki:
MAY 3 0 2013
j Pee- TOWN MANAGER'S OFFICE
TOWN OF SOUTH WINDSOR
I ff
Section 22a-6u of the Connecticut General Statutes requires the Connecticut Department of Energy and
Environmental Protection (DEEP) to provide you with notice of a significant environmental hazard
reported in your jurisdiction. Under the statute, DEEP is also notifying the state representative and state
senator representing the area in which the pollution has been identified. DEEP must, in addition, provide
notification to Federal and State Occupational Safety and Health Administration (OSHA) offices that
have jurisdiction, and is required to post on the Department's Internet website a listing of all notices
received under this law. Additional information about the reporting of significant environmental hazards
to DEEP is available in a DEEP fact sheet that can be found in the Remediation section of the DEEP
internet site at http://www.ct.gov/dep/`remediation.
Enclosed please find a copy of a Significant Environmental Hazard Report for 1708 Ellington Road in
South Windsor. The significant environmental hazard reported is that pollution detected in groundwater
above standards may threaten a drinking water well. Also enclosed is a copy of the DEEP's
acknowledgement letter in response to this hazard notification. Threatened drinking water supply wells
have been sampled multiple times and contain no contaminants of concern. In the acknowledgement
letter DEEP directed the property owner to contiue to monitor onsite groundwater condition and submitt
annual reports.
If you have any questions, or for further information regarding the Department's response or actions
under this program, please contact Rob Robinson of DEEP at (860) 424-3775.
Sincerely,
Patrick F. Bowe
Director
Remediation Division
Bureau of Water Protection and Land Reuse
Enclosures
PFB:kan
cc : Mr. Matthew B. Galligan, Town Manager, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
Dr. Gerald L. Schwartz, Director of Health, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
Connecticut Department of
ENERGY &
ENVIRONMENTAL
PROTECTION May 28, 20.13
79 Elm Street • Hartford, CT 06106-5127 www.ct.gov/deep Affirmative Action/Equal Opportunity Employer
ACKNOWLEDGEMENT
Mr. Gary Spelucim
10 Grace Lane
Portland, CT 06480
RE: Notification of Significant Environmental Hazard
Spelucin Property
1708 Ellington Road, South Windsor
Dear Mr. Spelucim:
This is to acknowledge receipt, on May 13, 2013 of written notification, under the requirements
of Connecticut General Statutes (CGS) Section 22a-6u. This notification reported the presence of
an environmental hazard at a property owned by you, located at 1708 Ellington Road in South
Windsor. The notification identified the following significant environmental hazard(s):
Groundwater polluted with Benzene at a concentration of 510 ug/L, exceeding the
adopted groundwater protection criteria, is or may be located within 500 feet upgradient
of a supply well.
Thank you for notifying the Department of Energy and Environmental Protection (DEEP) of this
condition, which you believe is due to an underground storage tank leak. It is DEEP's
understanding that in the intervening period downgradient drinking water wells were sampled and
were determined to be non -detect for the contaminant of concern.
DEEP requests, under CGS Section 22a-6u (k)(1), that you continue to monitor onsite
groundwater concentration for the contaminants of concern and submitt annual reports to the
attention of the staff member below. If groundwater conditions change, please collect additional
samples for the downgradient drinking water supply wells.
Pursuant to CGS Section 22a-6u(i), the owner of the water supply well tested, the local Health
Director, and the identified DEEP staff member must be notified in writing within 24 hours of
receipt of any analytical results indicating that a water supply well sample exceeds action levels
or maximum contaminant levels. In addition, DEEP requests that such notifications also inform
well owners of their statutory obligations under Section 22a-6u(i). Furthermore, if potable
drinking water wells become impacted with the contaminant of concern, actions need to be taken
to provide an immediate alternative supply of potable water and recommendations for continued
provision of potable water.
Except for environmental hazards identified under CGS 22a-6u Section (b)(1) or (h)(1), further
notifications resulting from investigations conducted as a result of this acknowledgement are not
necessary, provided that DEEP is promptly advised of sample results as requested above. Should
you wish to voluntarily remediate this site, several programs are available under Sections 22a-
133x and 22a-133y of the Connecticut General Statutes.
Page 1 of 2
For your information, pursuant to the requirements of CGS Section 22a-6u (m), the DEEP must
forward a copy of your written notification to the chief elected official of the municipality in
which the site is located, the state senator and state representative for the site's location, and state
and federal Occupational Safety and Health officials. DEEP also sends a copy to the Local
Health Director. In addition, DEEP sends a copy of this acknowledgement letter to these
individuals. The DEEP must also add this site to the "List of Significant Environmental Hazards
Reported to the DEEP" that is maintained on the DEEP internet site. Also, be advised that CGS
Section 22a-6u (1), requires that the Significant Environmental Hazard Notification Report be
conspicuously posted at the site not later than five days after the commencement of an activity by
any person that increases the likelihood of human exposure to known contaminants.
If you have any questions regarding your obligations specified in this letter, please contact Kevin
Neary of the DEEP at 860-424-3947.
Sincerely,
Patrick F. Bowe
Director
Remediation Division
Bureau of Water Protection and Land Reuse
PFB:kan
CERTIFIED MAIL RRR
cc: Mr. Joseph Santovasi, Advanced Environmental Interface, Inc. (AEI), 8 Old Indian Trail, Middletown, CT 06455
Kevin Neary, DEEP
Kenneth Feathers, DEEP
As noted above, under the provisions of CGS Section 22a-6u (m) copies are also provided to the following:
Dr. Gerald L. Schwartz, Director of Health, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
Mr. Matthew B. Galligan, Town Manager, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
The Honorable Thomas A. Delnicki, Mayor, Town of South Windsor, 1540 Sullivan Avenue, South Windsor, CT 06074
The Honorable William Aman, State Representative, Legislative Office Building, Room 2105, Hartford, CT 06106-1591
The Honorable Gary D. LeBeau, State Senator, State Capitol, Room C-417, Hartford, CT 06106-1591
Connecticut Department of Labor, Division of Occupational Safety & Health, 38 Wolcott Hill Rd, Wethersfield, CT 06109
Mr. Bill Freeman, Area Director, OSHA, 450 Main Street, Room 613, Hartford, CT 06103
HazNotMrg Ackn.dot Page 2 of 2
Connecticut Department of
Energy & Environmental Protection
Bureau of Water Protection & Land Reuse
Remediation Division
Notification under CGS 22a-6u
Please print or type to complete this form in accordance with
the instructions (DEEP-REM-SEH-INS-500).
Send completed report to:
SIGNIFICANT ENVIRONMENTAL HAZARD PROGRAM
REMEDIATION DIVISION
BUREAU OF WATER PROTECTION AND LAND REUSE
DEPARTMENT OF ENERGY AND ENVIRONMENTAL
PROTECTION
79 ELM STREET
HARTFORD, CT 06106-5127
Check box if addendum pages used.
Hazard Condition(s) Identified
Significant
Environmental
Hazard
Notification
WATER PROTECTION AND LAND REUSE
REMEDIATION DivlsiotJ
SITE NAME
ADDRESS t 7
TOWN
FILE TYPE
DEEP USE ONLY
RemGIS 7015 RemID 11 SEH# r E
[CGS Section 22a-6u subsectionj
❑
Explosion threat [6u-(h)]
Conditions Threatening Public or Private/Residential
Drinking Water Supply Wells:
❑
Volatile Organic Chemicals in groundwater
❑ Contamination is detected in supply well and is
threaten interior air quality [6u-(e)]
above groundwater protection criteria [6u-(b)]
❑
Surface water quality threatened by
❑ Contamination is detected in supply well but is
groundwater contamination [6u-(f)]
below groundwater protection criteria [6u-(c)]
❑
Surface soil contamination poses potential
U Groundwater above groundwater protection
direct exposure risk [6u-(d)]
criteria threatens supply well within 500 ft [6u-(g)]
Part I - Site Information
1. Site identification for parcel with pollution, on or emanating from the parcel, causing a
�iUnnivani envnunrnen[a1 nazara:
Name of Site Spelucin Property
Address or Location 1708 Ellington Road
City/Town South Windsor
State I CT I Zip Code 106074
2. Attach a copy of a topographic map with the site located thereon. Map Attached
3. Business/person submitting form: Is this entiMperson the site's owner? YES M NO I-1
Name
Gary C. Spelucin
Mailing Address
10 Grace Lane
City/Town
Portland
State
CT
Zip Code
06480
Business Phone
860-342-1581
Ext.
Fax
Authorized Rep.
Same
Title
Contact Person
Same
Title
DEEP-REM-SEH-FRM-500
1 of 6
Wmriffim
Part I - Site Information (continued)
3. & 4. Supplemental Information. If the person submitting this form is not the site owner, describe that
ie site and its owner and enter the site owner information in #4 see instructions .
4. Owner or Additional Party for site see instructions):
Name
Gary C. Spelucin
Mailing Address
10 Grace Lane
City/Town
Portland
State
I CT
Zip Code 06480
Business Phone
860-342-1581
Ext.
Fax
Contact Person
Same
Title
5. Operator/Tenant at site, if different from owner:
Name/Firm
Same
Mailing Address
City/Town
State
Zip Code
Business Phone
Ext.
Fax
Contact Person
Title
6. Technical Environmental Professional (TEP) who identified hazard: CHECK IF NONE ❑
Firm
Advanced Environmental Interface, Inc. (AEI)
Mailing Address
8 Old Indian Trail
City/Town
Middlefield
State
CT
Zip Code
06455
Business Phone
860-349-3559
Ext.
Fax
860-349-2286
Contact Person
Joseph Santovasi
Title
Principal
7. Environmental consultant for abatement, if not above TER
Firm
Mailing Address
City/Town
State
Zip Code
Business Phone
Ext.
Fax
Contact Person
Title
DEEP-REM-SEH-FRM-500 2 of 6 Rev. 1/17/12
Part II - Hazard Summary
1. How was the pollutant released?
❑
unknown
❑
landfill/wastepile
❑
septic system
®
UST leak
❑
spill/dumping
❑
burial
❑
dry well
❑
drums
❑
agricultural activity
❑
pit
❑
lagoon
❑
discharge
2. What is the general nature of the contamination?
®
petroleum/oils
Organic Chemicals
❑
metals
❑
sodium/salt
®
gasoline
®
volatile
❑ semivolatile
❑
cyanide
❑
leachate
®
fuel oil/diesel
®
nonchlorinated
❑ polyaromatic
❑
acid/base
❑
asbestos
❑
nitrate/fertilizer
❑
chlorinated
❑ pesticide/herbicide
❑
PCB
❑
radiation
3. For environmental sampling (soil or monitoring wells), list the analytical data that are the
basis for determining that a hazard condition exists. (See section 7 for supply well data.)
CHECK IF NO FNVIRONMFNTAI SAMPI FS COI I F(-TFr) n
Media
(Soil/GW)
Sample
IDle
Location
MW-6
Pollutant
Concentration
Notes
See attached table & site maps
GW
I Benzene
510 ppb
wore: usr onry me highest concentration for each medium/pollutant causing the hazard condition(s).
Attach additional sheets as needed.
4. Attach a site sketch map indicating the specific location of Site Map
the contamination or condition and applicable sampling locations. Attached
5. Was an inventory of drinking water supply wells within 500 feet conducted? YES ® NO ❑
6. If so, is this inventory report, including a parcel map of properties
within 500 feet that may be served by wells, included? N/A ❑YES ® No ❑
7. Identify affected or threatened drinking water supply wells: N/A ❑ UNKNOWN ❑
For hazard conditions based on supply well samples, list analvtical data establishing that the condition exists.
No. of
Supply Well analyses (if any)
Address/Town
Contact Name/Phone
people
*Pollutant/Concentration
1676 Ellington Rd., South
Karen Osborne
Windsor
860-291-3712
502.2 results non -detect
1700 Ellington Rd., South
Bob Urso
Windsor
860-268-2452
502.2 results non -detect
1700 Ellington Rd., South
Bob Urso
524.2 results non -detect
Windsor
860-268-2452
* See attached lab reports
/vote: Kerer ro aignmcanr tnwronmenral Hazard Keport Instructions. Attach additional sheets as needed.
8. Are hydrogeologic data/maps supporting the hazard identification included? YES ® NO ❑
DEEP-REM-SEH-FRM-500 3 of 6 Rev. 1/17/12
Part II Hazard Summary (continued)
9. Identify any other affected properties-
Address/Town I Contact Name/Phone
CHECK IF NONE AFFECTED ❑
How is Property Affected?
Attach additional sheets as needed.
10. Describe the land use of the site and surrounding area, and identify any sensitive land uses
within 1/4 mile of the site:
Mix of commercial, retail, and residential uses. Wetlands north and west of the site. Day care facility on abutting
site (1720 Ellington Rd.) to the east and northeast (upgradient).
11. If due to a recent spill. was spill notification made? NOT A SPILL I —I YES 71 NO n
Date
2002
DEEP contact
M. Williamson
Remarks
12. If due to a UST system release. was DEEP notified? NOT A UST RELEASE F-I YES N NO C-I
Date
2002
DEEP contact
M. Williamson
Remarks
13. For drinking water suDDly above criteria and explosion threat hazard conditions only:
Was oral notification to DEEP made? YES ❑ NO ❑
Date
DEEP contact
Remarks:
Was verification to TEP client made? N/A ® YES ❑ NO ❑
Date
Contact
Remarks:
14. Additional comments regarding the hazard condition(s)-
On-site contamination is the result of historic UST system releases that occured prior to G. Spelucin purchase of
property in 1984. Circa 1948-1984 property was a gasoline service station and auto repair garage. Mr. Spelucin
converted the property to commercial/office use upon his purchase in 1984. Residual contamination on the site is
limited in extent due to the presence of tight soils (silts and clays), which minimize the potential for migration.
Attach additional sheets as needed
DEEP-REM-SEH-FRM-500 4 of 6 Rev. 1/17/12
Part III - Past DEP Involvement (OPTIONAL)
1 _ Voluntnry Remediation/FCAF/Prnnerty Transfer filinris-
CHECK IF NONE M
Form
Date
CertifyingNerifying/Filing Party
1 DEEP Determination
2. DEEP staff involved with assessment or remediation of the site: CHECK IF NONE r
Time Period
DEEP Section
Name
M. Williamson
2002
Oil and Chemical
Spills
3. Renorts to DEEP Emeroencv Reseanse and Soill Prevention Division: CHECK IF NONE 7
Date
UST Release
or other spill?
Material Released
Petroleum (historic)
Quantity
Unknown
2002
UST
4. Describe other relevant DEEP permitting or enforcement involvement: CHECK IF NONEC
EPA ID#: CT I DEEP -WPC #: I DEEP Inventory #:
I RCRA Notifier Status. I RCRA Permit Status: I
Remarks
5. What environmental reports exist for the site and are available to DEEP? CHECK IF NONE n
Report
Type
Date
(mo/yr)
Preparer (Firm)
Attached?
(Y/N)
Previously
submitted?
Y
DEEP Unit to
which sent Ij
UST Fund
Phase 1
4/92
CEES
N
Phase 2
4/92
CEES
N
Y
UST Fund
Phase 3
Phase 2
6/02
ESI
N
Y
UST Fund
UST Fund
3/03
AEI (w/Phase 2+)
N
Y
UST Fund
Attach additional sheets as needed.
DEEP-REM-SEH-FRM-500 5 of 6 Rev. 1/17/12
Part IV - Actions to Abate Hazard CHECK IF PLAN OR REPORT ATTACHED ❑
Describe actions already taken to abate the hazard condition: CHECK IF NONE ❑
Gasoline USTs were removed prior to 1984 by the previous property owner. Heating oil UST and certain related
impacted soils were removed in 2002 by G. Spelucin. Private potable well at 1700 Ellington Rd. was sampled in
June 2002 and April 2013, and found to have no detectable concentrations of VOCs via Method 524.2 and Method
502.2, respectively. Private potable well at 1676 Ellington Rd. was sampled in April 2013, and found to have no
detectable concentrations of VOCs via Method 502.2.
Attach additional sheets as needed.
Describe actions to be taken to abate the hazard condition: CHECK IF NONE
Attach additional sheets as needed.
Part V — Signature of Notifying Partv
"I have personally examined and am familiar with the information submitted in this document and all
attachments, and certify that based on reasonable investigation the submitted information is true and
accurate to the best of my knowledge and belief. I certify that this form is complete and accurate as
prescribed by the Commissioner without alteration of the text."
pantor t me Gary C. Spelucin Title
type) (if applicable)
Signature 1 pate
Signifies information required by CGS Section 22a-6u.
DEEP-REM-SEH-FRM-500 6 of 6 Rev. 1/17/12