Loading...
HomeMy WebLinkAbout2005-6-7 - 1676 Ellington Road - Water Potability TestTam O-Ps-ou� V&U&ot 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 TELEPHONE (860) 644-2511 June 7, 2005 Mr. David Patria 566 Nevers Road South Windsor, CT 06074 Dear Mr. Patria, This is to confirm our recent conversation regarding your property at 1676 Ellington Road in South Windsor. Due to the fact that your existing well and septic system are closer than present day standards allow it was discussed and agreed upon that you would submit to the Health Department water testing results from the well to determine water quality every six months. Bacterial and routine chemical analysis is sufficient. It was also discussed and agreed upon that by the end of a three year period from occupancy, you would either connect to the public water, public sewers, or both. If you have questions please feel free to call me at (860) 644-2511 extension 248. Yours truly, Robert Deptula, R.S. Environmental Health Officer RD/cm Cc: Michele Lipe, Assistant Director of Planning Chris Dougan, Chief Building Official Analysis Report June 16, 2005 Sample Information Matrix: WATER Location Code: SPECIAL PHOENIX,LS-.,, 1g ACCp U `S U Q Environmental Laboratories, Inc. 587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06040 Tel. (860) 645-1102 Fax (860) 645-0823 FOR: Mr. David A. Patria 565 Nevers Rd. South Windsor, CT 06074 Custody Information Collected by: Received by: LB Laboratory Data Client ID: 1676 ELLINGTON RD., SOUTH WINDSOR OUTSIDE FAUCET Date Time 06/08/05 7:00 06/08/05 9:44 Phoenix I.D.: AG45879 Maximum Maximum Parameter Analysis y Contaminant AdvisoryDetection Measurement Result Level Level Limit Units Total Coliforms Absent 0/Absent 0 /100mis E. Coll Absent 0/Absent 0 /100m1s Nitrite as Nitrogen BDL 1 0.01 mg/L Nitrate as Nitrogen 3.3 10 0.05 mg/L Chloride 46 250 3.0 mg/L Chlorine Residual 0.04 0.02 mg/L Iron 0.025 0.3 0.002 mg/L Hardness (CaCO3) 175 200 0.10 mg/L Manganese 0.006 0.05 0.002 mg/L Sodium 18.2 28 0.10 mg/L Odor BDL 2 1 T.O.N. pH 7.91 6.5-8.5 0.10 pH Units Sulfate 36 250 3.0 mg/L Turbidity 0.24 5 0.10 Calcium 57.7 U.010 mg/L Color BDL 1 P.C.U. Magnesium 7.44 0.01 mg/L Explanation: BDL = Below Detection Limit (less than the the value in the detection level column, which is the lowest amount the laboratory can detect and report.) NL = No Limit (no limits established for this parameter.) This sample represents a potable (drinkable) water supply for the parameters tested. If there are any questions regarding this data, please call Phoenix Client Services at extension 200. Phyll's Shiller, Laboratory Director RECEIVED June 16, 2005 JUN 2 0 2005 SOUTH WINDSOR ENGINEERING DEPT