Loading...
HomeMy WebLinkAbout28 HUNTER DR UNIT 30 . - DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT ERM T# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPRO Dk:,,, 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# D to Building Inspector' Application must be printed or typed FEE SCHEDULE F;Te—nant / Location of Job: $0-$1,000=$15.00 Street Lot No. Over$1,000$15.00 per$1,000 or any fraction thereof gnation Apt. No. APPLICANT Q, G b4ME ' ?XVIVS APPLICANT ADDRahl O 0 � 5 n lms - --t Di APPLICANT PHONE# O W N St OWNER P JI< (4- 1/�- - OWNER ADDRESS 0S /✓ l� IQ UL� SoyIV r 0L ®60 Ob F OWNER PHONE D 0--&7I J U ESTIMATED COST$_ ! 000, O O b F .� IS THIS A CONTRACT CO S T? X Yes _No FEE ENCLOSED$ 1 �4J EEO S - O�� TYPE OF JOB: 3a O R•C New Installation KAlteration/Addition/Repair APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE,OF SYSTEM: TYPE F UILDING: 4HEATING RESIDENTIAL A/C 0 COMMERCIAL ❑VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR O UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL H ATING EQUIPMENTLUCLUDIN MAKE_&MODEL NO60 Cxao,6) ULa-P-k GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑OIL-GPM OIL TANK LOCATION :❑ INSIDER OUTSIDE CAPACITY ❑GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE AJLL CpO ING EQijPT(INCLLJpI�1 M &C iD�,L�NO.� / _ X et TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK P S t C/ y� & ad, THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30�0�3� �S1 � CONTRACTORS LICENSE NO TYPE STATE SIGNATURE OF APPLIC - DATE AFELL6 CORPORATE OFFICE P.O.BOX 548 WINDSOR LOCKS CT 06096 Plumbing,Electrical,Heating,Air Conditioning,Water Quality Solutions&Heating Oil HOME SERVICES y-'%)-nA- To Whom This May Concern: Aiello Home Services authorized Linda Dawson-Hayes, Ray Page, Russell Horrocks, Stephen Birch or Donna Heidelmark, Dave Arildsen, Garrett Cardwell, Tim Lynch,Joe Sparveri, Keith Tyler to pull permits for our company for any plumbing,heating or air conditioning replacement(s) or new installation(s). If you have any questions please call our office at 860-292-2600. This letter is for a permit for the property located at: ,P-g 9Vf)4t r'Dtr1 Ve— SDO�A 1',1�66r CT'OLn- Homeowner: Permit Fee Amount: Sincerely, ! $ Y Michael Jezouit President Local 860-292-2600 CT toll free 1-888-956-4455 Fax 860-292-2690 807 CT license numbers • P1-203350 • S1-303032 • E1-193730 Page 1 4/7/2008 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Registered To: Aiello Plumbing Heating and Air Conditioning For: Jr.Rempt Henry&Carolyn 28 Hunter dr south windsor, Ct 06074 Design Conditions: Windsor Locks,Bradley Field Indoor: Outdoor: Summer temperature: 72 Summer temperature: 95 Winter temperature: 70 Winter temperature: -6 Relative humidity: 50 Summer grains of moisture: 93 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 1,745.8 sq.ft. 23,517 2,726 26,243 61,916 (2 tons) First Floor 16,944 2,725 19,669 41,766 Bedroom 143 sq.ft. 2,385 365 2,750 5,965 Bathroom 54 sq.ft. 1,392 183 1,575 3,053 foyer 24 sq.ft. 579 256 835 3,259 Hall 48 sq.ft. 78 0 78 286 Living Room 221 sq.ft. 3,332 365 3,697 9,107 Hall(2) 49 sq.ft. 80 0 80 293 Dining Room 88 sq.ft. 1,890 402 2,292 6,561 Kitchen 81 sq.ft. 2,048 73 2,121 2,617 Bathroom(2) 48 sq.ft. 988 303 1,291 1,884 Bedroom(2) 240 sq.ft. 4,172 778 4,950 8,741 Lower Level 6,574 0 6,574 20,152 All Rooms 750 sq.ft. 6,574 0 6,574 20,152 Whole House 1,745.8 sq.ft. 23,517 2,726 26,243 61,916 (2 tons ) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual bads may vary due to weather and construction differences. STATEOFCONNI CTICUT - L 4rrj9D'S bf, MICHAEL R JEZOUIT PO BOX 548 y g WINDSOR LOCH,CT �6096 � WINP �I ;' p � #96 REG$ 0 5345- - 0 :� 31%2D08 i SIGNED � TA f j ��� CON f� j r MFp:��py��1��lE t Y WIND 96 -68 2008 0-5q p-o DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Dati5 f Job:: , &,y4ek UL $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation :;A�po. APPLICANT4te ! a>= `S R V i C ej _ APP CANT ADDRESS O Jr Aso Lac->�'s APPLICANT PHONE# O o2 a z 6 0 O W N St OWNER �` 0 n/ -- . OWNER ADD SS o�S u AIL W Oa OWNER PHONE Sji0— &L/`f' / 5 C ESTIMATED COST$ /DDO ® O .�� IS THIS A CONTRACT 15, 00 00'ST? �Yes _No FEE ENCLOSED$ �J/ O o TYPE OF JOB: ?J �SpR.C O� _New Installation XAlteration/Addition/Repair APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORKj� 'e�*CE &AP,ee K o4 4o 3o 4� 61- Ai, ���c4vujw ,6 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 193730r CONTRACTORS LICENSE NO. :'TYPE STATE SIGNATURE OF APPLICANT DATE AFELL6 CORPORATE OFFICE PO.BOX 548 WINDSOR LOCKS CT 06096 Plumbing,Electrical,Heating,Air Conditioning,Water Quality Solutions&Heating Oil HOME SERVICES Municipality: 600J41 ik l n Sd if Date: 'Job Name: r / r �! Street: City: fie„ hli n d sn Starting Date: _ Permit Fee: Job Description A114 IA4 D Per Public Act#91-95 This letter authorizes the following employees, Ray Page, Linda Dawson-Hayes, Russell Horrocks, Stephen Birch, and Donna Heidelmark to sign the permit as an agent of Aiello Home Services for the above mentioned job and location. hawn L G;/icense lw Applicable El — 193730 Local 860-292-2600 • CTtoll free 1-888-956-4455 • Fax 860-292-2690 807 CT license numbers • P1-203350 • S1-303032 • E1-193730 � I i I I I i I I i EUCTRICAL 3p CONTRACTOR II SHOFG 'tWAw PO • , i � r LIC R N ELC.0193730 EXPI 1 � t�-• 9/30/2008 I CrRAN Vt•.b`'� i SIGNED I I i i i I I