Loading...
HomeMy WebLinkAbout27 HEATHERWOOD DR DEPA_R_33UNT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR I O BUILDING DEPARTMENT APP O 1540 SULLIVAN AVENUE Bldg.Permit# 18 644-2511 EXT.230 (Date) (Building t ) Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000- $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Qr Q \ L u APPLICANT ADDRESS ( q S S v\.\`V&- Y-+--j t S V� C- APPLICANT PHONE# �W N SFq OWNER e- OWNER ADDRESS 2_'-1 n ��oad 9 r Oa OWNER PHONE UU0.2'Z5 C ESTIMATED COST $ IS THIS A CONTRACT COST? YES NO FEE ENCLOSED$ S l 0 0 TYPE OF JOB: �-2 lei' Z SOR-Co New Installation �Alteration/Addition Repair /01�(36 117 Revised 12/22/11 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A O(RESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES ❑ NO C3 BUSINESS CURRENT USE AND OCCUPANCY O ASSEMBLY O MERCANTILE FUTURE USE AND OCCUPANCY O EDUCATIONAL O FACTORY O STORAGE ENGINEER'S NAME PHONE O GARAGE 0 MIXED USE ADDRESS (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO. URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW O YES O NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE cNO. . TYPE STATE SIGNATURE OF APPLICANT `.ate,� \ DATE aN�kat ` APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 (PHONE) 860-644-2511 EXT. 230 DEPARTMENT DECISION PERMIT NUMBER: APPLICATION IS HEREBY: /`boo c� APPROVED: BLDG.PERMIT NUMBER: -� *DATE INSPECTOR LOCATION OF WORK: 7 �e ��"� n✓ APPLICANT: OWNER: TYPE OF STRUCTURE: �. ❑NEW BUILDING NAME NAME:, r,N l "f/�.0 -J`'QG! E ❑ADDITION PHONE 3-Af 97,3L' PHONE NUMBER: �LC�✓ k�6 5F9,f� EXISTING BUILDING ADDRESS: l D 'IN ' S! ADDRESS: 7-1Wt jCt-i!J / / TYPE OF USE: � � Li ✓ail / "✓wev-,. l� RESIDENTIAL. ❑ComNf RCIAL /o o 6ly� ELECTRICAL INFORMATION: FURTHER DESCRIPTION OF WORK: TYPE OF INSTALLATION: SIZE OF SERVICE: r � SIZE OF MAIN SERVICE: NUMBER OF METERS: NUMBER OF PANELS: CO NUMBER OF LIGHT CIRCUITS: ESTIMATED COST:S NUMBER OF SWITCHES: NUMBER OF LIGHT FD{TURES: FEE ENCLOSED:S � NUMBER OF A/C CIRCUITS: FEE SCHEDULE:$18 PER$1,000 OF THE ESTIMATED COST. NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS S1.00 OVER. (26 CENT EDUCATIONAL FEE INCLUDED AS NUMBER OF OUTLETS: PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: y' TYPE: € STATE: (� n SIGNATURE OF APPLICANT: F T ��� nr DATE: C V APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WII�iDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT '$ -� APP O 1540 SULLIVAN AVENUE ► ►o 19 644-2511 ext. 230 Bldg.Permit# Date BWWng Application must be printed or typed FTewant f Job: FEESCHEDULE R$041,000=$15.00 ,tA Over$1,000= Street Lot No. $15.00 per$1,060 or any fraction thereof signation Apt,No. APPLICANT 6--C,. e. APPLI ADDRESS Un APPLICANT'S NE# OWNER �q< OWNER ADDRESS tq OWNER PHONE CESTIMATED COST$ , I. O V IS THIS A CONTRACT COST? —\<"Ym No FEE ENCLOSED$ TYPE OF JOB: 020-31 OR-C New Installation Alteration/Addition/Repair �► �UUU2) Revised 03/05/10 f v APPLICATION FOR HVAC PERNUT(Continued from'ieverse side) TYPE fW SYSTEM: TYPE OF BUILDING: A`I NG ❑ RESIDENTIAL z ❑ CONIlVIERCTAL;: y . ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSUR9.LIlvIIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADLA.NT.HEAM EXISTING RADIATION ADDITIONAL RADIATION •'`-TOTALRADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL.HEAT LOSS(BTUH) °F(HEM LOSS SHEET MUSTACCOMPANYAPPLICATION) DESCRIBE ALL BEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) °d GROSS HEATING CAPACITK•(muTU BTUH},A NET RATING(OUTPUT B71JIM TYPE OF FUEL ❑ OM_GPM OIL TANK LOCATION:❑.INSIDE 0 OUTSIDE,CAPACITY ❑ GAS-INPUT_— LPG TANK CAPACITY ELECTRIC-KW' AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE. OF DIFFERENCE OF. TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) I`ONNAGE COOLING CAPACITY(BTUH13qq I VENTII,ATION i DES E ALI.'AIIt G UIP (INCLUDING EXHAUST EQUIPMENT) 3 2fit TOTAL SIZE OF SYSTEM(CFM) FRESH AIR I TAKE(aMO (PLANS MUSTACCOMPANYAPPLICATION) . FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORM�A1NCE OF SUCH WORK: q C r." W(�-;- CA- CONTRACTORS LICENSE NO. STATE q� SIGNATURE OFAPPLICA DATE ! 7 Load Short Form Job: Date: 12118=17 Entire House By: Setrite LLC Project Inf• • For: 26 Heatherwood Dr, South Windsor, CT Design Information Htg Clg Infiltration Outside db(°F) 0 88 Method Simplified Inside db(°F) 68 75 Construction quality Average Design TD(°F) 68 13 Fireplaces 1 (Average' Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/Ib) 47 32 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1975 cfm Actual air flow 1975 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Cig load Htg AVF Clg AVF (fP) (Btuh) (Btuh) (cfm) Wm) House 2166 78430 36939 1975 1975 Entire House d 2166 78430 36939 1975 1975 Other equip loads 0 0 Equip. @ 0.93 RSM 34279 Latent cooling 5136 TOTALS 2166 78430 39416 1975 1975 SoWdaiic values have been nuerwaly overrdden Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2017-Dec-18 180301 wrightSOft Rght-SUde®Universal 2017 17.0.23 RSU20986 page 1 Rl.l� C.UJsersypplenzio Documerts\Defauft rup Cale=W7 From Door faces: N ADOUGLASL NMCIMCM>��� .N 860-3ST-4952 wvrNdougiasmechazvca;services com December 18,2017 Job: Paul Cullen RE: Paul Cullen 26 Heatherwood Drive South Windsor,CT To Whom It May Concern: This letter is to authorize Jill Sturtevant to pull permits for impending job. If you should have any questions please do not hesitate to contact me at 860 573 4435. Thank you. Sincerely, Auylas f e�turtevamt Doug Sturtevant-HVAC TechNice President HEATING,PIPING t COOLING UTJUMrrED CONTRACTOR 11MMO SHEET METAL)0L1 Nn?EagON DOUGLAS J STURTEVANT DOUGLAS j STURTEVANT W7 TREE FUU.RD 2"Tam HI IL RD BERUN,CT 0"0--VU BF.RLM1,CT 4W?-.VU 11-11TG.0394918-S //1/f2017 88/3!/20t8 SH11[.7217- O191/7817 31/ 820 Four Rod Road,Berlin,CT 06037 SALES•SERVICE'INSTALLTION•HOME IMPROVEMENTSCr Ucense SS1394918 S HIG1064S793 I I NOTE t AQ-j 4-tl L-L E`�ZAZE`� PHASE Z This record drawing has been prepared In part on the basis of a limited in- O vestilistlon of subsurface conditions. The surveyor will not be responsible for any errors or omissions pertaining to 1� subsurface condition■ tncorporated Into N 4' 48' 44y V.1 this document. Absolutely no SJltlnc should take place without fiist accurate- �IOn.C-)cl - -_ _ ly locating all facilities. o 3Sri c ?,48 N sit" r— f 1 or1S 2� .—44.r IS.I� 1-lou S� 4.b N TF.'a 34 K q J' 1i THIS PROPERTY MAY �rDE MMIJECT _40: R yam. OF FiE0%UF6 AS MA-1 APPIM �,.IE 1 MNL7 � t i on Company � ' '✓ JHJ Construction 344 -- - `� O f0 .,aN �,\�� 658-EI I lnaton Road a -_ --344 South Windsor . CT 06074 -- — 282 0628 c� 1 o 49 4 d," - 1,---- —f _ _ _ _ L— F F+s 33&%1 ZOQ NE All NEfZ.W02n OQtVE ` 34-L � Q LL T LIF-lE5 F20'M M&P OIJ FILE TITI- C_ " F?V4,6,5 E 4 PLo-T PLAtit O PE tit PLOT PLAN SPACE �3Uk3DIV151oN - R � ZONE PA2-r HILL L 0 T 9 5 FOB DA2-f HILL- 12EALTY, ING , 4:�Ou-r0 VV IWD450lz, GONrj. DART HILL ESTATE S FRE) 1`Jo E, 4 PREPARED F 0 R 4(_A5-T01-10U;ZY, C56ALE Ili=4o1 GATE O-ZS-92 MAP tja, 9(0 •56p - IF DART HI LL R E A L TY , I N C . t2E,,lI5ED -TWIZu 8-7_-"3 SWEET S pF 113 ��trEE-T� S 0 U T H W INDSOR , C ON N. Fp►.�.I..D L AT E..C� a*� r�►-kv.1r3 12.-11�15 ► 0 Z.C1..II"(4 \1i0a_ATl o.a'j WITH fZESPE�.T To t✓vILAI►.1Ly l_n_c_A-�loiJ ___ d. n*reby declio-Pei that_"th1l. map`!.* #utlstantlally correct. REINO E. HYYPPA 81 ASSOCIATES This boundary survey was prtpered In accordance with the CIVIL ENGINEERS t3 LAND SURVEYORS standards of a Class A-2 wurvey as do-fined in the 'Recom- 124 HEBRON AVENUE mended Standards for SVr,veye and Maps in.thp State of Connecticut" as prepared and adopted by the Connecticut GLASTONBURY, CONN. 06033 Association of'.L'nd Surveyo . I , on September 13. 1984. (203) 633 -5218 SCALE I11= 40' DATE 12—►S-qS MAP No William Y.looit. ,L.S. LS.No. 11 2 Emong i f e x gg f � �� � 4 U.-EC 1 9 Im South Vo'inusor BUILDING DEPARTI4;_'', TO THE WIIOWG DPT, TOWY OF SOUi4i WIHidSOR This eartlflad that thls plan and specltic:tions are true snplsa of the proposed building w altorations to be sreatod et / l p vlw C� O!.�...r.L b^ "` Q2�� aura' 1 hpMM trrlMt MteMaMefs atst#d in eM/setlaw dw. : A7 MNM♦tali aM 1 dage.to comply wttb an ewllop f otW elate tows etN daft oro_ra as seO,l o aw�at��e.0 �0tl11101if 0"ttt111Mt d4ftne lk f•�Pn.. a" heel tiWewM of a burdin, T & fdr Iti ti 1WW1)1 +rAlett tie tt#e owwli.� a�� ordryt wr4 WO&OV Artea VeOMOW4 brmoft MAM IN �!r/AYUIli W�Mr. t '`� Wrr�nietltii6►3(ppetwq tea fwlr ,ate `bultdi ft Yltap"m 51111110111 �, 17 ty G (0 ti CER nFICATION OF ZONING COMPLIANCE a ` ` .�y Proposed buildi;�g;Q;t usc(s) and/or structurels) T g as shown on ih4u plant c pp-.wr)s) to be in :anto;rrtance t.,ith iut-r-eat South Wind egulations. Variancv; and spc;cW excepti,,,., may apply. Date -- �nMg Enforce rent Officec Vxb4 15'� a v� 34j.fi I SYp(/I►ra�'�2.9 � ►.� ��AtE Q AQ'T ►•fit LL E`.:TA'TE� P41ASE 2.. x� 1 ►.! W 46447 YJ 35Z. a¢E/► - 2Z,C,00 3S _ 0 3 -0 #1 �►4 _ R fs i6x 9t. 34 r —� N r ` q � rrF• � �Sv 9R.oG Z•1tw`,�e. 35n.4 .N ,�.1 isX Fir, Sr LAO 4.rs �� 35►.4 � .� u � \ THIS ro-PERTY MAY SE StMM-CT d x ° `'°3440, AaCURJ I AS MAY APPEAR. Ulu 14*4 5&&ES 4 j- _I 0n, JMJ Construction Company - - - - - 656 Ellington Road � 9 South Windsor . CT 06074 — 292-0628 - j� cft NEAZNERWaor7 --- v�t1VE- ,v i LOrT L.1WE5 F201�A M&P 0 W FI LE TI-fL E 0 Co►.,S-T V1VCTIC)ki " PHASE 4 Pt.._OT PLA w O P E t-1 c5PACE 43UMC)IV1510N -R 12 PLOT PLAN PAIZT HILL T4.TE5 P12r_P4.IZE0 L 0 T 95 Fog,' DA$Z-T' HILL Iz EA.L T Y, I t•J G . cbo11-7N NIWD650rzi c�NN. " BY DART HILL ESTATE S w_eo,.io E. N-(YPP4. G-ILA S-T�� 0U2Y, �3G�.LE I "=40' PREPARED F 0 R 60WJ -J, DATE >3-zs -q2 MAP wo, 9&P-5co - Ifs pq R T HILL REALTY , I N C . Fe-E'4I5ED Tu2U SWEET 5 of 16 S 0 U T H WINDSOR , C ONN. CEfL�\PIES) �x�tS"T'4►JTtn�..a_y �Oe-MELT' hereby declare that this sap Is substantially correct. REINO E. HYYPPA S ASSOCIATES This boundary survey watt prepared In accordance with the CIVIL ENGINEERS 5 LAND SURVEYORS standards of • Class A-2 survey as defined to the "Recon- aended Standards for Surveys and Maps in the State of 124 HEBRON AVENUE Connecticut" as prepared and adopted Y the Co ecticuc GLASTONBURY, CONN. 06033 Association of Lan urveyors Inc. c Septe at 13. 1984. (203) 633 -5218 SCALE 0=4D' DATE MAP No William Klock. L.S. Lf1fb. 1 SAP 1 ' ins. f � South 4VindsOr BUILDING DEPARTMENT TO THE BUILDING DEPT. TOWN OF SoUiH WIND.Sof This Certified that this plan and specifications are trur copies of the proposed building or alterations to be Q A erected at St►erl together with amendments,stated in application s.H. Ofiled with plan and I agree to Comply with all tonlol. RED Building and state laws and such ordrrs as shall a(`L r Ietuatl by the Building Department 199 5 of this a 1{esllon during pendency _ SEP 1 pp and final issuance of a build.o, tte.tnit. c ".d , N T Aftaubie�ce tq nQ"4"*v Cfi reautatingDui �~ 1 Guf^RNe4 w/Nf. Z vNtallal� AA"vld Thew filled W" . �'Nt1AlPlt IMr)b�rMof 4�� Electric # I DO y C` APPLICATION FOR BUILDING PERMIT Plumbing# fiW L C-0 7 Nta�i�r � HVAC# �n�e Date: 'O /if Sprinkler# 1 ADO 13`t Estimated Cost $ ,3Jfoo°' " FINAL APPROVALS Permit Fee $ 1630 Building COMPLETE RED BOXED AREAS Occupancy Fee $ 3D Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit Appr.forCO. SIGN ON REVERSE SIDE Total Fee $ ��U TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant 0 R Iv6ROS, C n lf T#c Location of Work oo A Lot No. Applicant's Address / 69� !?o�oa��y & Tel # S64, ✓6;4 9?,34 Townes 'l IYALtFo�O G i zip 1./08 Lic.# 040*a04 Owner �E tF A04 Al i a;A) 6404 ' Architect Owner's Address '17 Fgf&,&W*6Q Lk- Architect's Address ��214T:& Lv iniQ fCA Cz Zip 6 4o f 15 ' Zip- Sq.Ft.New Area: 1 st FI. _ 2nd FI. 3rd FI. Total New Area Purpose of this permit &1"/ CX�N. ��N� �cd/+? �A�+'+�� se i / A"7-C a f f ,� w�I/ L✓>°1..>� iT��� ti.1 /LEIS a /. ,�►,o�,,� City Water ] Well ) Septic System J Sewer J o 00L}I"I Ins: HO $P f��n Area Basement Garage Approved by IDate-�'- I�'� Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in'wch this building and its use is allowed. Signed o'fah� I hereby apply for a Certificate of Occccuupanc r the work described in this application for the permit. Signedf DO NOT W E BELOW THIS LINE INSPECTION COMMENTS INSPECTION FIELD SHEET 04/08/22 Printed by Middleton, Morgan 15 48 19 INSPECTION: 103467 FINAL PERMIT: STATUS: APPLICATION: 201800417 LOC: 27 HEATHERWOOD DRIVE SOUTH WINDSOR PROPERTY ID: 41300027 OWNER: GABLE JEFFREY A & ALISON A CONTRACTOR: REQUEST BY: PROJ DESC: REBUILD KITCHEN, DINING AND FAMILY ROOM INCLUDING KITCHEN WORK ORDER: INSPECTOR: ROSE RESULT: PASS REQUESTED: PRIORITY: SCHEDULED: COMPLETED: 06/15/18 UNPAID FEES: 18 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: ALL INSPECTIONS INSPECTED INSPECTOR RESULT INSP DESCRIPTION B001 FOOTING B002 FOUNDATION 04/12/18 ROSE PASS B003 FRAMING (ROUGH) 04/16/18 ROSE PASS B004 INSULATION KITCHEN WALL B005 FIREPLACE / CHIMNEY B006 WOOD / GAS STOVE E001 ELECTRIC SERVICE E002 ELECTRIC UNDERGROUND 04/12/18 ROSE PASS E003 ELECTRIC ROUGH KITCHEN WALL P001 WATER HEATER REPLACEMENT P002 PLUMBING UNDERGROUND 04/12/18 ROSE PASS P003 PLUMBING ROUGH WASHER 05/18/18 ROSE PASS P004 PLUMBING GAS TEST TO BOND GAS PIPING 1800139 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 04/11/2018 GIS ID:41300027 FEE: 630.00 MUNIS APPLICATION# 201800417 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: FORAN BROTHERS CONTRACTORS ADDRESS: 27 HEATHERWOOD DRIVE ADDRESS: 694 GOODWIN STREET OWNER: GABLE JEFFREY A&ALISON A EAST HARTFORD,CT 06108 27 HEATHERWOOD DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REBUILD KITCHEN,DINING AND FAMILY ROOM INCLUDING KITCHEN RENOVATION. REMOVE IOFT OF BEARING WALL BETWEEN KITCHEN AND DINING ROOM. RELOCATE PATIO DOOR AND REPLACE KITCHEN WINDOW. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: - --BUILDING OFFICIAL 4/112018 11:04 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1800017 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 01/10/2018 GIS ID:41300027 FEE: 180.00 MUNIS APPLICATION# 201800021 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: DOUGLAS MECHANICAL SERVICES INC. ADDRESS: 27 HEATHERWOOD DRIVE ADDRESS: 47 NORTHAMPTON LANE OWNER: GABLE JEFFREY A&ALISON A PLAINVILLE,CT 06062 27 HEATHERWOOD DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALLATION OF 3 1/2 TON AMERICAN STANDARD 14 SEER AIR HANDLER AND CONDENSING UNIT. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 1/10/2018 11:33 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1800094 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 04/11/2018 GIS ID:41300027 FEE: 180.00 MUNIS APPLICATION# 201800417 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ANTHONY FORAN ADDRESS: 27 HEATHERWOOD DRIVE ADDRESS: 120 KING STREET OWNER: GABLE JEFFREY A&ALISON A EAST HARTFORD,CT 06108 27 HEATHERWOOD DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REWIRING KITCHEN FOR REMODEL. ADD 23 RECESSED LIGHTS THROUGHOUT FIRST FLOOR. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 4/1 1/2018 11:13 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1800166 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER PLUMBING PERMIT DATE: 04/11/2018 GIS ID:41300027 FEE: 54.00 MUNIS APPLICATION# 201800417 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: IMPERIAL PLUMBING CO.,INC. ADDRESS: 27 HEATHERWOOD DRIVE ADDRESS: 648 SULLIVAN AVENUE OWNER: GABLE JEFFREY A&ALISON A P.O.BOX 875 27 HEATHERWOOD DRIVE SOUTH WINDSOR,CT 06074 SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: RE-INSTALL FIXTURES IN HALF BTH AND KITCHEN AFTER FIRE.MOVE LAUNDRY TO SECOND FLOOR. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 4/11/2018 11:05 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE