Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
26A-26J AMATO DR BLDG 26
APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 115060`7.11 APp 0 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building nspecto Application must be printed or typed FEE SCHEDULE F cation of Job: $041,000=$15.00Over$1,000= Street �-Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. a APPLICANT es► t+ APPLICANT ADDRESS Sv T obo��3 APPLICANT'S PHONE# C86b) 83q -2021 OWN 3 f OWNER GVl WOE [yo nMr, YV Att4 OWNER ADDRESS ,M ve yp�, ,�, °�► S p3, �,(' &05OWNER PHONE 2 Coo `�$ 5 00 0 ESTIMATED COST$ 5 C a ' U IS THIS A CONTRACT COST? ---Yes No 120 FEE ENCLOSED$ 10 �j ° �� TYPE OF JOB: 5�� SO R•C0� New Installation Alteration/Addition/Repair Ygob 7(� Revised 03/05/10 APPLICATION FOR IIVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ HEATING Er RESIDENTIAL 0"A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE °F INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATIN EQUIPMENT(INCLUDING MAKE&MODEL NO.) o GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) NI a TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPME T(INCLUDING MAKE&MODEL NO.) f IL 5&rc aik spl;_S 2.51n� TONNAGE .�j COOLING CAPACITY(BTUH)2 0,6 VENTILATION DESCRIBE ALL AIR LING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) --�� V 01 jCialttl�/ TOTAL SIZE OF SYSTEM(CFM) _FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK 11` p �h FA Deg et4 �c,gl e,,,�in'n t ege5 p.�e6t e � ) THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 'f p` �{rlAcTUR �. tteiifi�, ag-51L��na�tAn„1 C A,,I 1►C� 1 CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE ©b IS Company Info Name.Lloyd Thorpe Address:94 mountain Ad Ap1-D Location Suffield.Connecticul,%078 Phone:860-839-2021 Client Info Building name/description.Westgate Property Contact name:Lloyd Thorpe Address:26 C Amato Dore Location:South Windsor.Connecticut,United States Phone:(860)985 5969 Load Summary Total building area. 1.499.6 SgFI Total cooling load: 27.240.6 STUN Total coding tonnage. 2.3IOns Total tleatirlg bad: 0.0 BTUh Total aYBow: 1,114.1 CFM Projael Load Breakdown•C006M Windows,glass doors,skyli": 3,3ee.6 BTUh Envelope(walls,doors.roof.etc.): 8.e37.8 BTUh WWaban: BTUh Internal plan: BTUh Duct and blower heat gain: 5247.9 BTUh Ventilation: 2.002.2 8TUh Excursion adjustment bad 734.7 BTUh Total cooking 'tons Project Load Breakdown-Heating Windows.glass doors.skylights. &0 BTUh Envelope Iwalls.doors.root,etc.j: 0.0 BTUh Infiltration. QABTUh Duct heal Ions VentilaborVwinter humidification. 0.0 BTUh Hot water piping bad -._*BTUh Total heating. 0.0 BTUh Project AED Curve AEO —Arwaee Oro —Lewl Ls 6 383 5319 - Fj 4,255 - m 3,192 2 128 1064 B 9 10 11 12 13 14 15 16 17 18 19 20 lbw d Day ACCA•Approved Manual J8 Calculations 19:59 31 06-21.2015 This softwate was developed by Cannel Software Corporation. It has been approved by ACCA lot Manual J8 residential HVAC bad calculations System Load Summary System description:Split uniUcooling(16seer) Total building area: 1,499.E Total cooling load: 27,240.6 BTUh Total cooling tonnage: 2.3 tons Total healing load: 0.0 BTUh Total airflow: 1.114.1 CFM 8Wn1Mtn Mock Load Breakdown-Coobv Windows,glass doors,skylights. 3,344.6 BTUh Envelope(walls.doors.roof,etc.): 8,437.8 BTUh Infiltration. 0.0 BTUh Internal gain. 7,47&4 BTUh Duct and blower heat gain: 5.247.9 BTUh Ventilation: 2.002.2 BTUh Excursion adjustment load: 734.7 BTUh Total cooling: tons System Block Load Breakdown-Heating Windows,glass doors,skylights. 0.0 BTUh Envelope(walls.doors,roof,etc.j: 0.0 BTUh Infiltration 0.0 BTUh Duct heat loss: 0.0 BTUh Ventilafionlwinter humidification. 0.0 BTUh Hot water piping load. 0.0 BTUh Total heating: 0.0 BTUh System AED Curve AED —Avmp Gem _._.Low Lew, 6.393 5,319 c 4,255 - m 3,192 2.128 1.064 . 8 9 10 11 12 13 14 15 16 17 18 19 20 Four of Day ACCA-Approved Manual A Calculations 19:59:31 06-21.2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual A residential HVAC toad calculations. System Checksums - Cooling Total building area(SgFt): 1,499.6 Total building volume (CuFt): 14,996.0 Total cooling sensible load (BTUh): 24,496.9 Total cooling latent load (BTUh): 2,743.7 Total cooling load (BTUh): 27,240.6 Total tonnage (tons): 2.3 Total cooling infiltration airflow (CFM): 0.0 Total cooling ventilation airflow (CFM): 45.0 Total airflow (CFM): 1,114.1 Total infiltration air changes/hr(ACH): 0.00 Sensible heat coefficient (SHC): 1.10 Latent heat coefficient (LHC): 0.68 Cooling load density (BTUh/SgFt): 18.17 Cooling airflow density(CFM/SgFt): 0.74 Cooling airflow/load (CFM/Ton): 490.8 Cooling area/load (SgFt/Ton): 660.6 System Checksums - Heating Total building area(SgFt): 1,499.6 Total building volume(CuFt): 14,996.0 Total heating load (BTUh): 0.0 Total airflow (CFM): 1,114.1 Total building air changes/hr(ACH): 4.46 Sensible heat coefficient (SHC): 1.10 Latent heat coefficient (LHC): 0.68 Heating load density (BTUh/SgFt): 0.0 Heating airflow density(CFM/SgFt): 0.74 ACCA-Approved Manual J8 Calculations 19:59:31 06-21-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. Room Heating and Cooling Totals Room Name Cooling Load (BTUh) Heating Load (BTUh) Airflow (CFM) Office 3,475.1 0.0 149.0 Bedroom 1 2,467.4 0.0 94.0 Bathroom 1 ,436.5 0.0 47.1 Entrance Hall and C... 1 ,415.4 0.0 46.2 Kitchen 3,281 .5 0.0 111 .8 Family Room 4,202.0 0.0 172.9 Washer/Dryer Storage 1 ,029.0 0.0 28.6 Bedroom 2 2,234.0 0.0 83.4 Totals 19,540.9 0.0 733.0 ACCA-Approved Manual J8 Calculations 19:59:31 06-21 -2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations, System Block Load Breakdown-Cooling Description Value % Windows and glass doors: 3,344.6 12.3% Skylights: 0.0 0.0% Wood and metal doors: 191.1 0.7% Above grade walls: 3.275.3 12.0% Partition walls: 747.4 2.7% Below grade walls: 0.0 0.0% Ceilings: 4,224.0 15.5% Floors: 0.0 0.0% Infiltration: 0.0 0.0% Internal gain: 7,473.4 27.4% Duct heat gain: 3,540.9 13.0% Ventilation: 2,002.2 7.4% Blower heat gain: 1,707.0 6.3% Excursion adjustment load: 734.7 2.7% Total cooling: 27,240.6 100% System Block Load Breakdown-Heating Description Value % Windows and glass doors: 0.0 0.0% Skylights: 0.0 0.0% Wood and metal doors: 0.0 0.0% Above grade walls: 0.0 0.0% Partition walls: 0.0 0.0% Below grade walls: 0.0 0.0% Ceilings: 0.0 0.0% Floors: 0.0 0.0% Infiltration: 0.0 0.0% Duct heat loss: 0.0 0.0% Ventilation: 0.0 0.0% Hot water piping load: 0.0 0.0% Winter humidification load: 0.0 0.0% Total heating: 0.0 0% ACCA-Approvod Manual J8 Calculations 19:59:31 06-21-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. System Block Load Breakdown-Cooling >anr Crer pr�.H Windows,glass doors,skylights: }) ]BTUh Envelope(walls,doors,root,etc.): 8,437.8 BTUh Infiltration: ®BTUh Internal gain: BTUh Duct and blower heat gain: 5�49 BTUh Ventilation: 2 BTUh Excursion adjustment load: 734.7 STUh Total cooling: 2.3 tons System Block Load Breakdown-Heating Windows,glass doors,skylights: BTUh Envelope(walls,doors,roof,etc.): BTUh Infiltration: BTUh Duct heat loss: BTUh Ventilation/winter humidification: BTUh Hot water piping bad: BTUh Total heating: 0.0 BTUh System AED Curve —AED —Awsspa ew--UnW LNW 6.383 5,319 4,255 m 3.192 2,128 8 9 10 11 12 13 14 15 16 17 18 19 20 Four of Day ACCA-Approved Manual J8 Calculations 19:59:31 06-21-2015 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual JS residential HVAC load calculations. BUILDIFG PERMIT. STATE OF CONNECTICUT WORKERS'COMPENSATION COMMISSION Building Permit Affidavit for Property Owners or Sole Proprietors (Conn.Gen.Stat.§31.286b) Property located at_ 26 C Ne oao -U%u e, In the town of__ so&yn w,%AA, ,v rr� czy, Name of building permit applicant: U o4,wA—�\A!�En e Please check one: 1.—I am the owner of the above property. 2. �, I am the sole proprietor of a business. 2A.Name of business 2B.Federal Employer Identification Number(FEIN) .............................................................................................................::..... Pursuant to§31 286b,"a property owner or sole proprietor[who]intends to act as a general contractor or principal employer"may provide either a certificate of workers'compensation insurance or a"sword notarized affidavit...stating that he will require proof of workers' compensation insurance for all those employed on the job site in accordance with this chapter." Please check one: l._I do not intend to act as a general contractor or principal employer. [Sign and stop here] Signature of applicant 2.. 1/'I intend to act-as-a general contractor or principal employer.Applicant must either provide a certificate of workers'compensation insurance or sign the affidavit below. ................................. _.........................................................................;...... Affidavit I hereby swear and attest that I will rcquire proof of workers'compensation insurance for every contractor,subcontractor,or other worker before he/she engages in work on the above property in accordance with the Workers"Compensation Act(Chapter 568). I understand that pursuant to§31-275 C.G.S.,officers of a corporation and partners in a partnership may elect to be excluded from coverage by filing a waiver with the appropriate District Office;and that a so proprietor of a business is not required to have coverage unless he files his intent to e. Egnatdii of applicant Subscribed and sworn to before me this day of ,200 . (Notary Public/Commissioner of the Superior Court) APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 1 �p U 0 q `J AP 0 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# Date Building Ins ctor Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT /qX1,KGe-5 d L/ APPLICANT ADDRESS J'A So APPLICANT'S PHONE# OWNER 4)GSIAcL 6ot1a. 4TY cc,-nJ- ,., .�oW14, sit OWNER ADDRESS O i 6d1' G96, <;:�Ie,sA'V7 Lur'," OWNER PHONE ESTIMATED COST$ V IS THIS A CONTRACT COST? Yes No f% FEE ENCLOSED$ S U C) ° TYPE OF JOB• SOR•Co y New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: A-HEATING ❑ RESIDENTIAL ❑ A/C COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. P-*lgYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION 35&,fi ADDITIONAL RADIATION TOTAL RADIATION 35 vbo DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) j 1 c-fl��rr (/I^�dG/G1 S o"� 12-4:11U �ras �•��' ����f�..r sort .�� do lc.r. GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY 5—GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE& MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK /�c/P/,, i'l/IGvle _,flew L.& Y 6n,Gc THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 1���3 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application ' TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT D 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Bu ing Inspector Application must be printed or typed FEE SCHEDULE Location of Job: F a)t ," . 0 V" L $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT� rV1c C, A',[o j SI�S� ` A APPLICANT ADDRESS ` --'f� FkQy,,n �q t.4 o - APPLICANT PHONE#� �, 314 -17I e S OW N Se OWNER L4"—,N-2 1rOWl1 OWCNER ADDRESSTIA b OWNER PHONE $ C ESTIMATED COST$ .� IS THIS A CONTRACT COST? es _No FEE ENCLOSED$ S0 o`y� TYPE OF JOB: �# 7ga7 R C _New Installation VAlteration/Addition/Repair ����0a 6 ZO Revised 4/01//2002 APPLICATION FOR RVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE qF BUILDING: ❑HEATING RRESIDENTIAL �A/C COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING O STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION :0 INSIDE❑OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUHh (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOL G EQUIPMENT(INCLUDING MAKE&MODEL NO.) n TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK `(�(,_w kle-' THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYP STATE SIGNATURE OF APPLICANT DATE 2 J Total Mechanical Systems, LLC 34 Tiffany Lane - Bristol, CT 6010 860.314.1518 - nick@tmsllc.biz Whole House Heat Loss/Gain System I Lynette Brown Sales Consultant: Nick Dell'Aera 26 Amato Drive Unit C Proposal#: 494 South Windsor, CT 06074 Date: 06/01/2011 (860) 205-8254 Design Conditions: Winter Outdoor Temp. 6 Winter Indoor Design Temp: 70 Summer Outdoor Temp. 88 Summer Indoor Design Temp: 75 Loss/Gain Summary: Loss Gain Walls 4481 1167 Total BTUH Gain 19421 Windows 16473 7324 Capacity Multiplier 1.10 Doors 1236 322 A/C Unit BTUH Rating 21363 Ceilings 1766 1032 Skylights 0 0 Floors 5837 0 People/Kitchen 0 2400 Infiltration 17083 1983 Nominal A/C Unit Size* 2.0 Duct Loss/Gain 7031 711 Total Sensible 53907 14939 Gas Furnace Output BTUH 53907 Total Latent 0 4482 Total 53907 19421 Electric Furnace KW 15.8 Calculations are Estimated values based on a Whole House Heat Loss/Gain analysis for a typical application. Please refer to our Room by Room program for atypical applications. *Equipment Selection should match Manufacturers Performance Data. (Latent and Sensible) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 1 OODi Iot BUILDING DEPARTMENT APPROV D 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230-10 ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 4114.4 >ij � ''\y E $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS -:j b ti�,Ewy� E /Vl L47-G A.n . C fl Ln Ll lv l APPLICANT PHONE# -2 D A — S`1 x4 W N S F,q OWNER .IS/2 a AA) OWNER ADDRESS 411. -141111 A rci �2 , '—S c vT+4 Lt/,,,i o s v 2 G to c `/ O - . OWNER PHONE 4O 3 C ESTIMATED COST$ '-1 I ► 3 ✓ IS THIS A CONTRACT COS Yes _No �(J FEE ENCLOSED$ l��s LO/�� TYPE OF JOB: R C New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF B ELDING: ❑HEATING URESIDENTIAL ErA/L ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION :❑ INSIDEO OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE_--7;_� _OF INSIDE C OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH)i 5 j I? (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE 1(Z COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. c: r10b 1 - 5 H T� CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 362 New Haven Avenue TRIMC f-1('ll f ll ig Milford,CT 06460 Phone:(203)874-8279 ___ Fax:(203)877-4430 Appliance License:303303-S1 Date: Per Public Act 91-95 this letter authorizes X4 , c f, F ( 4-z _to act as an agent of Tri-City to file all necessary permits on behalf of Tri-City and Christopher Mawdsley p Mun icipality: � a, T ,} lam✓►.�,O 5 i)2. Job Name &Address: V erE ?LD �Q S,; rTt l'J'j $O Starting Date: -3 1 - Zo . v Description of work: � 7. ._-, Christopher Mawdsley S 1-390622 F:\Sales\lnstail\Permit Authorization Letter Tri-City S i.doc Tri City Heating & Cooling Date of request Z�, i a 362 New Haven Avenue Date needed SA p Milford, CT 06460 Projected start date 203 874-8279 Type of Work to be performed ( e( , C— c Cost of Job Building Permit Request Form Job Information Job# Customer Name Address of work ?AAA Town S. W,-,LL5c7- , of 07y Homeowner Address Telephone `B 6 0 '"Z i Lf 6 `t o Heating AC Oil Tank Basic Info Basic Info Basic Info Make Ne eplaceme Old Location Model# Makes New Location Capacity of FumaceBoiler Model# -30( Capacity Size Extra Info Location of unit Extra Info For Tri-City Office Use Only: Temperature Inside 70 BTU per hour Heat Loss/Gain Temperature Outside 0 Type of refdgerent Cert.of Ins. Temperature of Boiler Water/PSI 180!12psi Type of condensing unit Copy of Lic. Total Net Load Fan Capacity CFM Authorization: Unit Rating Type of heat pump Signed Check Fan Rating CFM Number of Zones Permit Application: Square foot to be cooled l K d v Bldg Dept Temperature Inside 70 Permit Hours: Temperature Outside 0 Applicant Agent Horse Power of Motor Date to be Pulled: We hereby authorize Gofor Services Inc.,and its employees and agents,(hereafter referrred to as"Gofor"")to apply for and procure building permits for our company's contracted work and we also authorize Gofor to present this letter or a photocopy hereof to any building official in order to demonstrate its authority to apply for and procure such permits on our behalf.In furtherance of this authorization""we attach copies of our current contractor's licenses for the several states in which we anticipate Gofor will be requested to apply for and procure such permits for us.We represent that we are familiar with the applications for building permits and related documents in the various locations in which Gofor will be requested to submit applications on our behalf.Gofor is expressly authorized to sign on our behalf applications for such permits and any other related documents,(and we agree that we,not Gofor or its employees or agents)shall be deemed to be the signer of any such applications and documents.We further agree to hold Gofor and its employees and agents harmless for and indemnify them against any claims and costs(including attorneys fees)arising from their activities contemplated hereunder. Name: Signature Date: -- /0-s/_1 0 Tri-City Appliance Heating & Cooling 362 New Haven Ave.-Milford, CT 6460 203-395-3442-Dan@tricityappliance.com Whole House Heat Loss/Gain System I Brian Kulvete Sales Consultant: Dan German 26 A Amato Drive Proposal#: 10462 South Windsor, CT 06074 Date: 03/16/2010 203-794-0990 Design Conditions: Winter Outdoor Temp. 0 Winter Indoor Design Temp: 70 Summer Outdoor Temp. 95 Summer Indoor Design Temp: 72 Loss/Gain Summary: Loss Gain Walls 6823 2599 Total BTUH Gain 15718 Windows 1698 954 Capacity Multiplier 1.00 Doors 3381 1290 A/C Unit BTUH Rating 15718 Ceilings 1188 782 Skylights 0 0 Floors 3926 0 People/Kitchen 0 2400 Infiltration 15153 2489 Nominal A/C Unit Size* 1.5 Duct Loss/Gain 6434 1577 Total Sensible 38603 12091 Gas Furnace Output BTUH 38603 Total Latent 0 3627 Total 38603 15718 F- Electric Furnace KW 11.3 Calculations are Estimated values based on a Whole House Heat Loss/Gain analysis for a typical application. Please refer to our Room by Room program for atypical applications. 'Equipment Selection should match Manufacturers Performance Data. (Latent and Sensible) Tri-City Heating and Cooling 362 New Haven Ave.-Milford,CT 06460 203.791.2429 203.874.8279 203.395.3442- Customized Proposal Brian Kulvete Sales Consultant: Dan German 26 A Amato Drive Proposal#: 10462 South Windsor CT 06074 Date: 03/16/2010 206-794-0990 System 1 e Hereby propose to furnish,Install and service equipment for your home as specified below: (1) Trane 13 SEER 1.5 Tons Standard Efficiency AC condensing unit (R-410A) Model 4TTB3018 (1)ADP 3-Speed Air Handler Model PCME/CC21624 (1) Copper Insulated Lineset (1) New Outdoor Wiring with Disconnect (1) Labor to install complete system (1) 100% Satisfaction Guaranteed in Writing (1) 10 year compressor warranty (1) 1 year FREE Service Partner Plan Accepted / Declined customer signature (1)All necessary building permits &inspections System I Investment $ 0 r Down Payment $0.00 ` 48 Monthly Investments of $138.87 With Approved Financing a1 qly7 L'� 001 ovgz OZ04 0C(AI l/z Included in every Installation: All material listed above is guaranteed as specified.All work will be Authorized completed In a professional manner.Any deviation from above specificatlons Signature involving extra costs will be executed onty upon written change orders. Sales Co Qr r Dan Germ Note:This proposal may be withdrawn by 10 Days us if not accepted within We hereby propose to furnish labor&material,complete in accordance with the above specifications,for the sum of: $ Payment to be made as follows: The above prices,specifications and conditions are satisfactory and are hereby accepted.You are authorized to do work as specified. .— Payment will be made as outlined above. Signature: Acceptance Date: 3/3ho Signature: