Loading...
HomeMy WebLinkAbout261 HILTON DR �ayWS0 APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT /4Do 4Z2 APPR 1540 SULLIVAN AVENUE Bldg.Permit# '« 644-2511.ext. 230 Date Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 1�'1 i }} I+�� $0-$1,000=$15.00 ca F- Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT A I e-`I o 0O m L Se Y V 1 CL5 APPLICANT ADDRESS i')U P- CaX 5-IS W i M SO r LOCKS, CT n(n og h APPLICANT'S PHONE# J bb-QQQ- OWNER 1 A OWN SFq� OWNER ADDRESS a6 1 i OWNER PHONE $K)-5QS-L4 3 P C * `" ESTIMATED COST$ UO IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ TYPE OF JOB: V�- 35(P S R'CO New Installation Alteration/Addition/Repair o�b O l 3cPS Revised 03/05/10 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE O SYSTEM: TYPE QF�BUH DING: HEATING / 1,RESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE °F DIFFERENCE °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENTgroba CLUDING MAKE&MODEL NO.) r M - GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE °F DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (BEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE N TYPE STATE SIGNATURE OF APPLICAN DAB Cu I Corporate Office CEL ,V 600 Old County Circle, P. O. Box 548, Windsor Locks, CT 06096 f„LICE�s> ALO n_ Local 860-292-2600 9 Fax 860-292-2690 FOR - }S1FETl Connecticut Toll Free 1-888-956-4455 HOME SERVICES ,` ,„.ri5 AielloHomeServices.com 9 Aiello is an AA/EOE To Whom This May Concern: Aiello Home Services authorized Linda Dawson-Hayes, Stephen Birch, Dave Howard, Garrett Cardwell, Tim Lynch, Keith Tyler, Randy Weidig,Matt Cormier, Robert Bilodeau,Nick White, Mark Putorti,Bill Faitella, Kevin Vaughan, Cindy Nicewicz, ----- --Alesha-LaBelle,Matthew-Rose,Dave Arildsen,Tim Fabuien,Joseph ArrQyo;-Scott Matyskiela, to pull permits for our company for any plumbing,heating or air conditioning replacement(s)or new installation(s). If you have any questions please call our office at 860-292-2600. This letter is for a permit for the property located at: Homeowner:\/_%cot ry-A+'a) C) Permit Fee Amount: $ VO Sincerely, Michael Jezouit President HEATING,PIPING&C,00I4N9 UNLIMITED CONTRACTOR LM*HTED SU � NTRACTOR MICH-AEL R ZOUIT M1C EL R ZbbIT BOS' WIND$6R- O' K �GT,.06096-0548 I WINDY' .- j Y.4�1 a96-0548 EFTIE EXPIRE LIC /RE NO.LIC. fl PIRES HTG.0303032-S1 04` �f20'174 08/31/2015 f SHM.0005345-S - 09.j01/2014 OS/31/2015 j r , SIGNED SIGNED ) HEATING • PLUMBING • ELECTRICAL • GENERATORS • OIL DELIVERY • WATER QUALITY • AIR CONDITIONING 17/13 Company Info Name: Aiello home services Address: 600 old county cir. Location: Windsor locks , Ct., 06096 Phone: 860-292-2600 Client Info Building name/description: Col. Contact name: Jon & virigina wiggins Address: 261 hilton dr. South windsor ct. 06074 Location: Hartford, Connecticut, United States Phone: 860-528-4319 Load Summary Total building area: 1,488.0 SgFt Total cooling load: 0.0 BTUh Total cooling tonnage:e: 0.0 tons Total heating load: 44,300.8 BTUh Total airflow: 899.4 CFM ACCA-Approved Manual J8 Calculations 19:39:57 09-23-2014 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. Checksums - Cooling Total building area (SgFt): 1,488.0 Total building volume (CuFt): 11,904.0 Total cooling sensible load (BTUh): 0.0 Total cooling latent load (BTUh): 0.0 Total cooling load (BTUh): 0.0 Total tonnage (tons): 0.0 Total cooling infiltration airflow (CFM): 0.0 Total cooling ventilation airflow (CFM): 35.4 Total airflow (CFM): 899.4 Total infiltration air changes/hr (ACH): 0.00 Sensible heat coefficient (SHC): 1.09 Latent heat coefficient (LHC): 0.68 Cooling load density (BTUh/SgFt): 0.00 Cooling airflow density (CFM/SgFt): 0.60 Cooling airflow/load (CFM/Ton): 0.0 Cooling area/load (SgFt/Ton): 0.0 Checksums - Heating Total building area (SgFt): 1,488.0 Total building volume (CuFt): 11,904.0 Total heating load (BTUh): 44,300.8 Total airflow (CFM): 899.4 Total building air changes/hr (ACH): 4.53 Sensible heat coefficient (SHC): 1.09 Latent heat coefficient (LHC): 0.68 Heating load density (BTUh/SgFt): 29.8 Heating airflow density (CFM/SgFt): 0.60 ACCA-Approved Manual J8 Calculations 19:39:57 09-23-2014 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. II Block Load Breakdown - Cooling DescripWn Value % Windows and glass doors: 0.0 0.0% Skylights: 0.0 0.0% Wood and metal doors: 0.0 0.0°Yo Above grade walls: 0.0 0.0% Partition walls: 0.0 0.0% Below grade walls: 0.0 0.0% Ceilings: 0.0 0.0% Floors: 0.0 0.0% Infiltration: 0.0 0.0% Internal gain: 0.0 O.OYO Duct heat gain: 0.0 0.0/0 Ventilation: 0.0 0.0% Blower heat gain: 0.0 0.0% Excursion adjustment load: 0.0 0.0% Total cooling: 0.0 0.0% Block Load Breakdown - Heating Description Value % Windows and glass doors: 6,822.9 15.4°Yo Skylights: 0.0 0.00Yo Wood and metal doors: 1,146.6 2.6(Y. Above grade walls: 10,069.6 22.7% Partition walls: 0.0 0.01YO Below grade walls: 0.0 0.0% Ceilings: 3,457.4 7.8% Floors: 0.0 0.0% Infiltration: 5,768.8 13.0% Duct heat loss: 14,326.2 32.3% Ventilation: 2,709.3 6.1% Hot water piping load: 0.0 0.0% Winter humidification load: 0.0 0.0% Total heating: 44,300.8 100.... ACCA-Approved Manual J8 Calculations 19:39:57 09-23-2014 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. Room Heating and Cooling Totals Room Name Cooling Load (BTUh) Heating Load (BTUh) Airflow (CFM) A Room 0.0 0.0 0.0 Totals 0.0 0.0 0.0 ACCA-Approved Manual A Calculations 19:39:57 09-23-2014 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual J8 residential HVAC load calculations. System Block Load Breakdown - Cooling !— Windows.glass doors,WwWft BTUh — Envelope(wak,doors,roof,aft.): 8TUh -- -- Infiltration: BTUh Internal gain: fl BTUh Duct and bower heat gain: 04 BTUh - -- -- -- -- -- --- --Ventilations 0.0 BTUh ---- E=ursion adjustment bad: 0.0 BTUh Total cooling: 0.0 BTUh System Block Load Breakdown - Heating Windows. glass doors, skylights 6.822.9 BTUh Envelope(walls.doors,roof,etc.): 14.673.6 BTUh hAttratwn: 5,768.4 BTUh Duct heat loss:_ 14,328A BTUh VentilatiorVv inter humKffcation: - 2.709.1 BTUh Hot water piping load: O.0 BTUh Total heating: _ 44,300.8 BTUh Sy"n AEC Curve ACCA-Approved Manual JA Calculadons 19:39:57 W23-2014 This software was developed by Carmel Software Corporation. It has been approved by ACCA for Manual A residential HVAC bad calculations. 1400422 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 10/02/2014 GIS ID:44100261 FEE: 135.00 MUNIS APPLICATION# 201401365 -BUILDING DESCRIPTION: f R , APPLICANT : t ;:4 LOCATION NAME: AIELLO HOME SERVICES" ADDRESS: 261-HILTON DRIVE ADDRESS: P O BOX 548 'OWNER: f WIGGINS JON A&VIRGINIA C WINDSOR LOCKS,CT 06096 �:` 2_61 :HILTON DRIVE "  SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REPLACE GAS BOILER. I_ ) SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE.WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 10/2/2014 12:30 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE