HomeMy WebLinkAbout261 HILTON DR �ayWS0
APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT /4Do 4Z2
APPR 1540 SULLIVAN AVENUE Bldg.Permit#
'« 644-2511.ext. 230
Date Building Inspector
Application must be printed or typed
Location of Job:
FEE SCHEDULE 1�'1 i }} I+��
$0-$1,000=$15.00 ca F-
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT A I e-`I o 0O m L Se Y V 1 CL5
APPLICANT ADDRESS i')U P- CaX 5-IS W i M SO r
LOCKS, CT n(n og h
APPLICANT'S PHONE# J bb-QQQ-
OWNER 1
A OWN SFq� OWNER ADDRESS a6 1 i
OWNER PHONE $K)-5QS-L4 3 P
C * `" ESTIMATED COST$ UO
IS THIS A CONTRACT COST? Yes No
FEE ENCLOSED$
TYPE OF JOB: V�- 35(P
S R'CO New Installation
Alteration/Addition/Repair
o�b O l 3cPS
Revised 03/05/10
APPLICATION FOR HVAC PERMIT(Continued from reverse side)
TYPE O SYSTEM: TYPE QF�BUH DING:
HEATING / 1,RESIDENTIAL
❑ A/C ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP.OUTSIDE OF INSIDE °F DIFFERENCE °F
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENTgroba
CLUDING MAKE&MODEL NO.)
r M -
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY
GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE OF INSIDE °F DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (BEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE N TYPE STATE
SIGNATURE OF APPLICAN DAB Cu I
Corporate Office
CEL ,V 600 Old County Circle, P. O. Box 548, Windsor Locks, CT 06096
f„LICE�s>
ALO n_
Local 860-292-2600 9 Fax 860-292-2690
FOR -
}S1FETl Connecticut Toll Free 1-888-956-4455
HOME SERVICES ,` ,„.ri5
AielloHomeServices.com 9 Aiello is an AA/EOE
To Whom This May Concern:
Aiello Home Services authorized Linda Dawson-Hayes, Stephen Birch, Dave Howard,
Garrett Cardwell, Tim Lynch, Keith Tyler, Randy Weidig,Matt Cormier, Robert
Bilodeau,Nick White, Mark Putorti,Bill Faitella, Kevin Vaughan, Cindy Nicewicz,
----- --Alesha-LaBelle,Matthew-Rose,Dave Arildsen,Tim Fabuien,Joseph ArrQyo;-Scott
Matyskiela, to pull permits for our company for any plumbing,heating or air
conditioning replacement(s)or new installation(s). If you have any questions please call
our office at 860-292-2600.
This letter is for a permit for the property located at:
Homeowner:\/_%cot ry-A+'a) C)
Permit Fee Amount: $ VO
Sincerely,
Michael Jezouit
President
HEATING,PIPING&C,00I4N9 UNLIMITED CONTRACTOR LM*HTED SU � NTRACTOR
MICH-AEL R ZOUIT M1C EL R ZbbIT
BOS'
WIND$6R- O' K �GT,.06096-0548 I WINDY' .-
j Y.4�1 a96-0548
EFTIE EXPIRE LIC /RE NO.LIC. fl PIRES
HTG.0303032-S1 04` �f20'174 08/31/2015 f SHM.0005345-S - 09.j01/2014 OS/31/2015
j r ,
SIGNED SIGNED )
HEATING • PLUMBING • ELECTRICAL • GENERATORS • OIL DELIVERY • WATER QUALITY • AIR CONDITIONING
17/13
Company Info
Name: Aiello home services
Address: 600 old county cir.
Location: Windsor locks , Ct., 06096
Phone: 860-292-2600
Client Info
Building name/description: Col.
Contact name: Jon & virigina wiggins
Address: 261 hilton dr. South windsor ct. 06074
Location: Hartford, Connecticut, United States
Phone: 860-528-4319
Load Summary
Total building area: 1,488.0 SgFt
Total cooling load: 0.0 BTUh
Total cooling tonnage:e: 0.0 tons
Total heating load: 44,300.8 BTUh
Total airflow: 899.4 CFM
ACCA-Approved Manual J8 Calculations 19:39:57 09-23-2014
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
Checksums - Cooling
Total building area (SgFt): 1,488.0
Total building volume (CuFt): 11,904.0
Total cooling sensible load (BTUh): 0.0
Total cooling latent load (BTUh): 0.0
Total cooling load (BTUh): 0.0
Total tonnage (tons): 0.0
Total cooling infiltration airflow (CFM): 0.0
Total cooling ventilation airflow (CFM): 35.4
Total airflow (CFM): 899.4
Total infiltration air changes/hr (ACH): 0.00
Sensible heat coefficient (SHC): 1.09
Latent heat coefficient (LHC): 0.68
Cooling load density (BTUh/SgFt): 0.00
Cooling airflow density (CFM/SgFt): 0.60
Cooling airflow/load (CFM/Ton): 0.0
Cooling area/load (SgFt/Ton): 0.0
Checksums - Heating
Total building area (SgFt): 1,488.0
Total building volume (CuFt): 11,904.0
Total heating load (BTUh): 44,300.8
Total airflow (CFM): 899.4
Total building air changes/hr (ACH): 4.53
Sensible heat coefficient (SHC): 1.09
Latent heat coefficient (LHC): 0.68
Heating load density (BTUh/SgFt): 29.8
Heating airflow density (CFM/SgFt): 0.60
ACCA-Approved Manual J8 Calculations 19:39:57 09-23-2014
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
II
Block Load Breakdown - Cooling
DescripWn Value %
Windows and glass doors: 0.0 0.0%
Skylights: 0.0 0.0%
Wood and metal doors: 0.0 0.0°Yo
Above grade walls: 0.0 0.0%
Partition walls: 0.0 0.0%
Below grade walls: 0.0 0.0%
Ceilings: 0.0 0.0%
Floors: 0.0 0.0%
Infiltration: 0.0 0.0%
Internal gain: 0.0 O.OYO
Duct heat gain: 0.0 0.0/0
Ventilation: 0.0 0.0%
Blower heat gain: 0.0 0.0%
Excursion adjustment load: 0.0 0.0%
Total cooling: 0.0 0.0%
Block Load Breakdown - Heating
Description Value %
Windows and glass doors: 6,822.9 15.4°Yo
Skylights: 0.0 0.00Yo
Wood and metal doors: 1,146.6 2.6(Y.
Above grade walls: 10,069.6 22.7%
Partition walls: 0.0 0.01YO
Below grade walls: 0.0 0.0%
Ceilings: 3,457.4 7.8%
Floors: 0.0 0.0%
Infiltration: 5,768.8 13.0%
Duct heat loss: 14,326.2 32.3%
Ventilation: 2,709.3 6.1%
Hot water piping load: 0.0 0.0%
Winter humidification load: 0.0 0.0%
Total heating: 44,300.8 100....
ACCA-Approved Manual J8 Calculations 19:39:57 09-23-2014
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
Room Heating and Cooling Totals
Room Name Cooling Load (BTUh) Heating Load (BTUh) Airflow (CFM)
A Room 0.0 0.0 0.0
Totals 0.0 0.0 0.0
ACCA-Approved Manual A Calculations 19:39:57 09-23-2014
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual J8 residential HVAC load calculations.
System Block Load Breakdown - Cooling
!— Windows.glass doors,WwWft BTUh —
Envelope(wak,doors,roof,aft.): 8TUh
-- -- Infiltration: BTUh
Internal gain: fl BTUh
Duct and bower heat gain: 04 BTUh - --
-- -- -- -- --- --Ventilations 0.0 BTUh ----
E=ursion adjustment bad: 0.0 BTUh
Total cooling: 0.0 BTUh
System Block Load Breakdown - Heating
Windows. glass doors, skylights 6.822.9 BTUh
Envelope(walls.doors,roof,etc.): 14.673.6 BTUh
hAttratwn: 5,768.4 BTUh
Duct heat loss:_ 14,328A BTUh
VentilatiorVv inter humKffcation: - 2.709.1 BTUh
Hot water piping load: O.0 BTUh
Total heating: _ 44,300.8 BTUh
Sy"n AEC Curve
ACCA-Approved Manual JA Calculadons 19:39:57 W23-2014
This software was developed by Carmel Software Corporation.
It has been approved by ACCA for Manual A residential HVAC bad calculations.
1400422 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 10/02/2014
GIS ID:44100261 FEE: 135.00
MUNIS APPLICATION# 201401365 -BUILDING DESCRIPTION:
f
R ,
APPLICANT : t ;:4 LOCATION
NAME: AIELLO HOME SERVICES" ADDRESS: 261-HILTON DRIVE
ADDRESS: P O BOX 548 'OWNER: f WIGGINS JON A&VIRGINIA C
WINDSOR LOCKS,CT 06096 �:` 2_61 :HILTON DRIVE
"  SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: REPLACE GAS BOILER. I_ )
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE.WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
10/2/2014 12:30 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE