APPLICATION FOR ELECTRICAL PERMIT
TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT
1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 (PHONE) 860-644-2511 EXT. 230
PERMIT NUMBER:
DEPARTMENT DECISION � �
APPLICATION IS HEREBY:
APPROVED: BLDG.PERMIT NUMBER:
DATE I SPE OR
LOCATION OF WORK: � 5�
APPLICANT: OWNER: TYPE OF STRUCTURE:
O NEW BUILDING
Q NAME: A�S`nCl 1` I��n Oo
NAME: I�-{ Sb1V`Y Q c n l ❑ADDITION
T PHONE NUMBER: O O'�.� D 3"I /
PHONE NUMBER: a O3 �,'�rl ❑EXISTING BUILDING
ADDRESS:I m li L lot CLU ADDRESS: a 51 s(`I 1IY�Q
CYNMM t, CT Ou %4 0 TYPE OF USE:
S(,RESIDENTIAL ❑COMMERCIAL
ELECTRICAL INFORMATION: FURTHER DESCRIPTION OF WORK:
TYPE OF INSTALLATION:
SIZE OF SERVICE: forA 9� �Q V GLY\P,
SIZE OF MAIN SERVICE: 1
NUMBER OF METERS:
NUMBER OF PANELS: r Li
NUMBER OF LIGHT CIRCUITS: ESTIMATED COST: 101
5 v
I
NUMBER OF SWITCHES:
NUMBER OF LIGHT FIXTURES: FEE ENCLOSED: ' u
NUMBER OF A/C CIRCUITS:
FEE SCHEDULE:$18 PER$1,000 OF THE ESTIMATED COST.
NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS
NUMBER OF OUTLETS: $1.00 OVER. (.26 CENT EDUCATIONAL FEE INCLUDED AS PART
OF THE PERMIT FEE)
THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL
ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO.: Q 5 5 5 q TYPE: STATE:
SIGNATURE OF APPLICANT: DATE:
WESTSHORE
DESIGN ENGINEERS. P.C.
WMI:=
100 GREAT OAKS BLVD. I SUITE 115
ALBANY 1 NEW YORK 1 12203
To: Trinity Solar
7 McKee Place
Cheshire, CT 06410
Date: December 31, 2019
Ref.. 19120842
Subject: Arshad Mehmood
251 Skyline Rd.
South Windsor, CT
Dear Trinity Solar,
The following references the Arshad Mehmood residence in South Windsor, CT:
1 Existing roof framing
Pre-fabricated/engineered wood truss is 2x4 at 24"o.c.This existing structure is capable to support
all the loads that are indicated below for this photovoltaic project
2. Roof Loading
- 4.33psf dead load (modules plus mounting hardware)
- 30psf ground snow load
- 5.7psf roof materials (1.7psf 2x6, 1.5psf sheathing, 2.5psf asphalt shingles)
- Exposure Category B, 135mph wind gust (3 sec.)
This installation design will be in general conformance to the manufacturer's specifications,and complies
with all applicable laws, codes, and ordinances, and 2018 State CT Building Code, International
Residential Code/IRC 2015. The spacing and fastening of the mounting brackets is to have a maximum
of 48"o.c. span between mounting brackets, staggered, and secured using 5/16" diameter corrosive
resistant steel lag bolts. A minimum of 2.5" of penetration per lag bolt is required, which is adequate to
resist all 125mph wind live loads including wind shear. Per NDS Section 11.1.4 clearance holes equal to
the diameter of the shank need to be bored into a primary framing member for the full length to the
threaded portion of the screw to avoid splitting of the framing member.
Thank you.
Westshore Design Engineers C.NN
A.. ..
NO.32451
IC E H St
i./sS,O N A.�
Exp.1.31.21
12/31/2019
John Eibert Nicolas Nitti, PE
Project Coordinator President
WestShore Design Engineers 1100 Great Oaks Blvd.I Suite 115 1 Albany,NY 12203 1518.313.7153
i, 4ith all 200"
is st-11
penl-lc
t .11ce
of
t,. toridition the'
c d,rs shall b-
C, These filed with
cc,- Itiol.
CIA"
WESTSHORE
DESIGN ENGINEERS. P.C.
WM - 100 GREAT OAKS BLVD. I SUITE 115
ALBANY I NEW YORK I 12203
To: Trinity Solar
7 McKee Place
Cheshire, CT 06410
Date: December 31, 2019
Ref.. 19120842
Subject: Arshad Mehmood
251 Skyline Rd.
South Windsor, CT
Dear Trinity Solar,
The following references the Arshad Mehmood residence in South Windsor, CT:
1 Existing roof framing
Pre-fabricated/engineered wood truss is 2x4 at 24"o.c.This existing structure is capable to support
all the loads that are indicated below for this photovoltaic project
2. Roof Loading
- 4.33psf dead load (modules plus mounting hardware)
- 30psf ground snow load
- 5.7psf roof materials (1.7psf 2x6, 1.5psf sheathing, 2.5psf asphalt shingles)
- Exposure Category B, 135mph wind gust(3 sec.)
This installation design will be in general conformance to the manufacturer's specifications, and complies
with all applicable laws, codes, and ordinances, and 2018 State CT Building Code, International
Residential Code/IRC 2015. The spacing and fastening of the mounting brackets is to have a maximum
of 48"o.c. span between mounting brackets, staggered, and secured using 5/16" diameter corrosive
resistant steel lag bolts. A minimum of 2.5" of penetration per lag bolt is required, which is adequate to
resist all 125mph wind live loads including wind shear. Per NDS Section 1 1.1.4 clearance holes equal to
the diameter of the shank need to be bored into a primary framing member for the full length to the
threaded portion of the screw to avoid splitting of the framing member.
Thank you.
Westshore Design Engineers
oo�'., NO.32451
Fs •............... v ��
i';/',O N A;10
Exp.1.31.21
12/31/2019
John Eibert Nicolas Nitti, PE
Project Coordinator President
WestShore Design Engineers 1100 Great Oaks Blvd.I Suite 115 1 Albany,NY 12203 1518.313.7153
end
t or
Sir"
"d in P,Iic_aion 8^1
all zonint
as Shall
It d-614 penden,
I! Of a bumdln-
nt
the
Signed t"' Condition
is nC1" b,
his P10"
mplied -These filed *lth
It 0"
CIO"
d
(Tr)tl aSOLAR 7 Mckee Place.Cheshire,CT 06410
CT El Lic#195559 Phone:(203)701-3724 Fax:(203)687-4205
205
Authorization to Apply for BUILDING PERMIT
The bearer of this letter is authorized as an agent of TRINITY SOLAR to sign for the following BUILDING PERMIT
(Sec.20-338b)
Today's Date: I / 10D Job Start Date:
a
Municipality where work shall be performed
South Windsor
Job Name
Mehmood, Arshad-
Job Address
251 Skyline Road, South Windsor, CT
Description of Job
installation of roof mounted solar panels
Name of Authorized Agent
Steve Labulis/Brie Longo/Nicole Riedinger/Yaasmiyn Lightfoot/Hannah Birch/Alexis Young
Name of Licensed Contractor:TRINITY HEATING&AIR INC.
CT License/Reg No:HIC.0635520
Signature of Licensed Contractor
EONE nfPWVEMENT CONTRACTOR
TPJNT YRfATTNG&AgaRNC
7 MCKFE FL
CRESMM Cr 06410.1119 1
t
TRDIM 901AIt
—4ad.ow.ZlTZ
rave
Ri1CAls35520 12/01/2019 11/30/2020
srn[o�. s
Sec.20.338b.Building permit applications.N ho may sign.Any licensed contractor who seeks to obtain a permit from a building official may sign the building permit application personally or delegate the
signing of the building permit application to an employee,subcontractor or other agent of the licensed contractor,provided,the licensed contractor's employee,subcontractor or other agent submits to the building
official a dazed letter on the licensed contractor's letterhead,signed by the licensed contractor,stating that the bearer of the letter is authorized to sign the building permit application as the agent of the licensed
contractor.The letter shall rat be a copy or a facsimile,but shall be an original letter bearing the original signature of the licensed contractor.The letter shall also include:(1)The name of the municipality where
the work is to be performed;(2)the job name or a description of the job:(3)the starting date of the job;(4)the name of the licensed contractor,(5)the name of the licensed contractor's agent;and(6)the license
numbers of all contractors to be involved in the work.
I W li
T i
S 01 AR 7 Mckee Place Cheshire, CT 06410
CT El Lic#195559 Phone:(203)701-3724 Fax:(203)687-4205
Authorization to Apply for ELECTRICAL PERMIT
The bearer of this letter is authorized as an agent of TRINITY SOLAR to sign for the following ELECTRICAL PERMIT.
(Sec.20-338b)
Today's Date: `—���cy v Job Start Date:
Municipality where work shall be performed
South Windsor
Job Name
Mehmood, Arshad-
Job Address
251 Skyline Road, South Windsor, CT
Description of Job
installation of roof mounted solar panels
Name of Authorized Agent
Steve Labulis/Brie Longo/Nicole Riedinger/Yaasmiyn Lightfoot/Hannah Birch/Alexis Young
Name of Licensed Contractor: Paul Lamoureux Jr
CT License/Reg No: ELC.0195559-El
Signature of Licensed Contractor
ELECTRICAL L-NLIMTTED CONTRACTOR
PAIIL H LAMOURHUX JR
C21t— we
=9�rnvy('P 06181 I
tr<e,.a iu+«die lg4iee.
ELC.0195559-E1 10/01/2019 09/30/2020
Sec.21H338b.Hui)diny;permit applications.\1 ho m:n.i{n.Any licensed contractor who seeks to obtain a permit from a building official may sign the building permit application personally or delegate the
signing of the building permit application to an employee,subcontractor or other agent of the licensed contractor,provided,the licensed contractor's employee,subcontractor or other agent submits to the building
official a dated letter on the licensed contractor's letterhead,signed by the licensed contractor,stating that the bearer of the letter is authorized to sign the budding permit application as the agent of the licensed
contractor.The letter shall not be a copy or a facsimile,but shall be an original letter bearing the original signature of the licensed contractor.The letter shall also include:(I)The name of the municipality where
the work is to be performed;(2)the job name or a desenption of the job:(3)the starting date of the job;(4)the name of the licensed contractor,(5)the name of the licensed contractor's agent;and(6)the license
numbers of all contractors to be involved in the work.20
DATE(MMIDD/YYYY)
CERTIFICATE OF LIABILITY INSURANCE 12/30n019
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s)
PRODUCER CONTACT
NAME: Mark Grasela
Arthur J.Gallagher Risk Management Services,Inc. PHONE FAx
4000 Midlantic Drive Suite 200 A/C No.ExtI,856482-9900 ac No, 856-482-1888
Mount Laurel NJ 08054 ADDRESS: CherryHill.BSD.CertM@AJG.com
INSURERS AFFORDING COVERAGE NAIC N
INSURER A:American Guarantee and Liability Ins Co 26247
INSURED TRINHEA-03 INSURER a:Gotham Insurance Company 25569
Trinity Heating&Air,Inc.DBA Trinity Solar 611 W JOHNSON AVE INSURER C:National Union Fire Insurance Company of Pittsburg19445
CHESHIRE,CT 06410 INSURER D:Liberty International Underwriters
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER:1506993838 REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
ILTR SU TYPE OF INSURANCE I=ADDL VIVID POLICY NUMBER MMIIDDPOLICY EFF M IDDPOLIC EXP
LIMITS
B X COMMERCUILGENERALLUIBILITY GL201900013378 12/31/2019 6/1/2021 EACH OCCURRENCE $2,000.000
CLAIMS-MADE a PREMOCCUR DAMAGE R NTED
PREMISES Ea occurrence $100,000
MED EXP(Any one person) $5,000
PERSONAL 6 ADV INJURY $1,000,000
GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000
POLICY a PRO-
JECT LOC PRODUCTS-COMP/OPAGG $2,000,000
OTHER: $
C AUTOMOBILE LIABILITY CA 2960141 12/31/2019 6/1/2020 COEa acciMBINED SINGLE LIMIT $2,000.000
dent
X ANY AUTO BODILY INJURY(Per person) $
OWNED SCHEDULED BODILY INJURY(Per accident) $
AUTOS ONLY AUTOS
HIRED NON-OWNED PROPERTYDAMAGE $
1AUTOS ONLY AUTOS ONLY Per accident
$
B UMBRELLALIAB X OCCUR UM201900008887 12/31/2019 6/1/2021 EACH OCCURRENCE 55,000,000
D X EXCESS LIAB AEC 1448324-01 12/31/2019 6/1/2021
CLAIMS-MADE 1000231834-04 12/31/2019 6/1/2021 AGGREGATE $5,000,000
DED RETENTIONS Limit z of$5,000,000 $19,000,000
C WORKERS COMPENSATION WC 13588107 12/31/2019 6/1/2020 PER oTH-
AND EMPLOYERS'LIABILITY Y/N STATUTE ER
ANYPROPRIETOR/PARTNER/EXECUTIVE ❑ N I A E.L.EACH ACCIDENT $1,000,000
OFFICERIMEMBEREXCLUDED?
(Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $1,000,000
If yes,describe under
DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000
C Automobile CA 2960141 12/31/2019 6/1/2020 AN Other Units $250/500
Comp/Collusion Ded. Truck-Tractors and
Semt•Tra lers $250/500
DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space is required)
Evidence of Insurance.
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ACCORDANCE WITH THE POLICY PROVISIONS.
Evidence of Insurance AUTHORIZED REPRESENTATIVE
A
01988.2015 ACORD CORPORATION. All rights reserved.
ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD
rani y
SOLAR
HOMEOWNERS AUTHORIZATION FORM
1, Arshad Mehmood
(print name)
am the owner of the property located at address:
251 Skyline road South Windsor CT
(print address)
I hereby authorize Trinity Solar, and their subcontracting company
, to act as my Agent for the limited purpose of
applying for and obtaining local building and other permits from the
Authority Having Jurisdiction as required for the installation of a
Photovoltaic System located on my Property.
This authorization includes the transfer/re-administering, and/or
cancellation of any existing permits on file for the purpose of
updating/applying with an alternate subcontractor.
Customer Signature:
Date: 12/9/19 1 2/9/201 s
Print Name• Arshad Mehmood
INSTALLATION OF NEW SKYLINE ROAD.
ROOF MOUNTED PV SOLAR SYSTEM
251 SKYLINE ROAD
SOUTH WIN DSO R CT 06074
�' '1 •¢� i ITI 1� Issued/Revisions
(U thk ..
�l ISSUED TO IOWNSNIV iOR VERMIT Uv.t
VICINITY MAP SITE NO. DESCRIPTION DATE
SCALE: NTS Project Title:
MEHMOOD,ARSHAD-
TRINITY ACCT#:2019-12-396658
Project Address:
251 SKYLINE ROAD
SOUTH WINDSOR,CT 06074
41.853518,-72.558189
GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED S H E ET I N D EX
Drawing Title:
1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO 8L NOTES
RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS
EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLT AMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSEDPVSOLARSVSTEM
DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT
CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM
INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE
2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.THIS SET OF PLANS SHALL MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information
RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE NOT BE UTILIZED AS CONSTRUCTION MOP MAIN DISTRIBUTION PANEL
EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE DRAWINGS UNTIL REVISED TO INDICATE MLO MAIN LUG ONLY DRAWING DATE: 1/6/2020
DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. 'ISSUED FOR CONSTRUCTION'. MTD MOUNTED DRAWN BY: RTC
IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR 16 ALL INFORMATION SHOWN MUST BE MTG MOUNTING
3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE CERTIFIED PRIOR TO USE FOR N NEUTRAL REVISED BY:
RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CONSTRUCTION ACTIVITIES. NEC NATIONAL ELECTRICAL CODE
UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT
COMPONENT AND INVERTER MANUALS ARTICLE 690 3 705. NON NUMBER System Information:
PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS ABBREVIATIONS NTS NOT TO SCALE DC SYSTEM SIZE: 3.78kW
CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE OCP OVER CURRENT PROTECTION
ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL AMP AMPERE P POLE AC SYSTEM SIZE:POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AC ALTERNATING CURRENT PB PULL BOX TOTAL MODULE COUNT: 2 1
THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AL ALUMINUM PH 0 PHASE MODULES USED: HANWHA 315
AF AMP.FRAME PVC POLY-VINYL CHLORIDE CONDUIT
SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AFF ABOVE FINISHED FLOOR PWR POWER MODULE SPEC#: Q.PEAK DUO BILK-GS 315
4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION.
MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFG ABOVE FINISHED GRADE CITY QUANTITY UTILITY COMPANY: 5197 4 2 4036
CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AWG CONDUITAMERICA WIRE GAUGE SIN RIGID GALVANIZED STEEL UTILITY ACCT R: 5197 64 2
ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL C CONDUIT (GENERIC TERM OF JS SOLID NEUTRAL UTILITY METER#: SUNNOVA
SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING RACEWAY,PROVIDE AS JSWBD SWITCHBOARD DEAL TYPE: SUNNOVA
SPECIFIED) TYP TYPICAL
COURSE ON SITE. CONDUCTIVITY CHECKS. CB COMBINER BOX
5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND U.0.1. UNLESS OTHERWISE INDICATED
CKT CIRCUIT WP THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO WEATHERPROOF
XF
CT CURRENT TRANSFORMER XFMR TRANSFORMER
MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CU COPPER -72 MOUNT 72 INCHES TO BOTTOM Rev.No. Sheet
TOGETHER AND THAT EACH OF THE OPERATION MANUAL. DC DIRECT CURRENT
INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC OF ABOVE FINISHED FLOOR OR
DISC DISCONNECT SWITCH GRADE
IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT P 1 P V 1
6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DWG DRAWING
BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND EC ELECTRICAL SYSTEM INSTALLER
EMT ELECTRICAL METALLIC TUBING
CONVENTIONS OF THE NATIONAL OWNERS. FS FUSIBLE SWITCH
ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND FU FUSE
WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE GND GROUND
GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL GFI GROUND FAULT INTERRUPTER
7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: HZ FREQUENCY (CYCLES PER
INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL
'UL'LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, SECOND)
3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS Trin * ty
GENERALNOTES SOLAR
IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY OF EQUIPMENT. 2211 Allenwood Road
Wall,New Jersey 07719 877!86-1283
NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS
'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE T"URE
NRAC CLAMP
NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS)
(REFER TO EQUIPMENT SCHEDULE
FOR SPECS AND QUANTITIES) SOLAR MODULEAR MODULE
NEW MOUNTING FOOT/ATTACHMENT
POINTS,TYPICAL (REFER TO \ LS
ENGINEERING LETTER FOR SPACING X UNIRAC"L"FOOTRAC RAIL .�` 90
AND DETAILS) t0 Q (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) �?
NEW UNIRAC RAIL,TYPICAL
Lr
TO BE MOUNTED PERPINDICULAR TO UNIRAC FLASHINGSTING ASPHALT SHINGLES —J,
STRUCTURE(REFER TO UNIRAC (REFER TO SPEC SHEET FOR DETAILS)
ER TO ENGINEERSLETTER FOR SPECS)
SPECIFICATION/DATA SHEET FOR i (/� --
DETAILS)
NEW END CLIP,TYPICAL S.S.LAG BOLT APOC SEALANT I
O ee SZZ \\
(REFER TO UNIRAC SPECIFICATION I SOLAR MODULES SHALL NOT
—♦ -- —� DATA SHEET FOR DETAILS) EXISTING RAFTER EXCEED PEAK HEIGHT.
NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECIFICATIO4
(REFER TO UNIRAC SPECIFICATION/
DATA SHEET FOR DETAILS)
nATTACHMENT&CLIP DETAIL nPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF QHEIGHT FROM GROUND LEVEL TO PEAK OF ROOF
SCALE NOT TO SCALE SCALE:NOT TO SCALE SCALE NOT TO SCALE
ARRAY SCHEDULE
Issued/Revisions
— 1 1
— — 1 In PT ISSUED TO IONNSNIP FOR PERMR VEM-
ILI RN LLNE)
BACK ¢ — (pROpE I NO. DESCRIPTION DATE
BACK
p r
D 1 J Project Title:
GROUND ACCESS ROOF ACCESS I 1 MEHMOOD,ARSHAD-
ITRINITY ACCT#:2019-12-396658
1 1 Project Address:
ROOF ACCESS ROOF ACCESS ZDC
251 SKYLINE ROAD
SOUTH WINDSOR,CT 06074
p uD 1 41.853518,-72.558189
Drawing Title:
I
I PROPOSED PV SOLAR SYSTEM
1
R2 1 J
J Drawing Information
® DRAWING DATE: 1/6/2020
DRAWN BY: RTC
ROOF ACCESS I I REVISED BY:
1 J
J System Information:
I DC SYSTEM SIZE: 3.78kW
AC SYSTEM SIZE: 3kW
1 TOTAL MODULE COUNT: 12
1 GROUND ACCESS MODULES USED: HANWHA 315
J
MODULE SPEC#: Q.PEAK DUO BLK-GS 315
I FRONT J UTILITY COMPANY: EVERSOURCE
UTILITY ACCT#: 5197 402 4036
NOTES: FRONT UTILITY METER#: 886286422
t.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 1 DEAL TYPE: SUNNOVA
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. I J
2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. J
3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. — — Rev.No. Sheet
4.) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(q .
5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. `
SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE P PV 2
INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL CITY SPEC#
RD ARRAY SCHEDULE FOR MORE INFORMATION UED I INSTALLED OUTSIDE (UTILITY ACCESSIBLE) SP TO BE INSTALLED 12 HANWHA 315(Q.PEAK DUO BLK-GS 315)
INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE3000H-US000BNC4
M I INDICATES EXISTING METER LOCATION [] I INDICATE PANELS THAT USE MICRO INVERTERS.
REFER TO EQUIPMENT SCHEDULE FOR SPECS.
ROOF1
MODULES:D - OTHER OBSTRUCTIONS
PITCH:27' INDICATES EXISTING ELECTRICAL PANEL INDICATES NEW PRODUCTION METER TO BE
ORIENTATION:
ION:58' EP LOCATION: INSIDE P INSTALLED OUTSIDE.
ROOF 2 SOLAR
MODULES:12
PITCH:23 INDICATES NEW FUSED PV DISCONNECT TO BE INDICATES NEW INVERTER TO BE
ORIENTATION:238 OD INSTALLED INSIDE ® INSTALLED OUTSIDE.
2211 Allenwood Road
A REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey C7719 877-786-7283
Engineer/License Holder.
ARRAY CIRCUIT WIRING NOTES
1.)LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2017 SOLAR MODULES MOUNTED TO ROOF ON 1 ARRAY
12-315W MODULES W/1 SOLAR EDGE P320 PER MODULE
2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB 8"x8"
TEMPERATURE FOR ASHRAE LOCATION MOSTSIMILAR TO 1 STRING OF12 MODULES IN SERIES-380Vmax --- ------ JUNCTION ____________ __________- ----------------------------------1
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT
BOX I r
TEMP=-16'C *TERMINATED INSIDE INVERTER 1
3. HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED U I +
ON ASHRAE HIGHEST MONTH 2%DRY BULB I
TEMPERATURE FOR ASHRAE LOCATION MOSTSIMILAR TO -.r!vI d u,rt t'+s ^I+n wnd sp.ciflcnticrsat-etr. I
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= a.N, t Uf the proposed building or alterations to b, I
33'C -"e._t.d at I
4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN I
TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED Stree ( ��
STATES(PALM SPRINGS,CA IS44.1-C). FORLESSTHAN9 t-z ther µ!th r.r-r-] r ;ar Et.t.d in application an. 1
CURRENT-CARRYING CONDUCTORS IN AROOF-MOUNTED
•r1 d I tth p1•n ",A 1 •,y t F c•n,p17 with all zoning Issued/Revisions
I SUNLIT CONDUIT OORDESIG LEAST TEMPE"ATURE OF
OR
ooirg ,,no I:.s d s,ch order.as shall b•
THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS
(ALL OF UNITED STATES) If `y the v Ll�pir1.rnt during pendenc, 1
this application and final issuance of a building I
5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS _ermit. I
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I Signed Pt ISSUED TOTOWNSHIP FM PERMIT 1/6/2=
1
NEC 690.12(A)THROUGH(D) rhis plan Is eppreved suti.ct to the condition that I NO. DESCRIPTION DATE
6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED ,rdors and ordiriuccs regulating bAI441ng shall be 1
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC :on:pli•:d with. i Project Title:
SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) ;on itiona A III These filed with I MEHMOOD,ARSHAD-
7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE
IDENTIFIED WITH THE FOLLOWING OUTER FINISH: TRINITY ACCT#:2019 12-396658
NEGA
POSITIVE I
CONDUCTORS =RED Building Inspeeto� ciers
NEGATIVNE CONDUCTORS=BLACK
NEC210.5(C)(2) _ , Project Address:
8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV EXISTING 240V 10 NOTE: �L�1JC?
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE 10120/240V j Vj lOOA MAIN BREAKER INTERNAL REVENUE GRADE MONITORING _JJ I 251 SKYLINE ROAD
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER 100A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER SOUTH WINDSOR,CT�6�74
SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24'SHALL SOLAR EDGE FIN.RWND-3D-240-MB r "
CONTAIN 5 20 CURRENT CARYING CONDUCTORS AND 41.853518,-72.558189
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN
5 9 CURRENT CARRYING CONDUCTORS.
Drawing Title:
9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS a3
OTHERWISE NOTED
10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON LOCKABLE 60A DISCONNECT 60A UNFUSED
PROPOSED PV SOLAR SYSTEM
ROOFTOP AND SHALL BE LIMITED TO 12"IF USED FUSED W/20A FUSES DISCONNECT
OUTDOORS nINVERTERD
zaov l z4ov 1 Drawing Information
11.OVERCURRENT PROTECTION FOR CONDUCTORS "OiATONfUtP"` 6p'""°"`°'""`
sasses sasses
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE DRAWING DATE: 1/6/2020
LOCATED WITHIN 10'OF THE POINT OF CONNECTION NECDRAWN BY: RTC
705.31 --
I REVISED BY:
12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE AUTILITY AND THE OTHER AN INVERTER,PV BACKFEED ---- 0 _ Ir --- m e e e e 0 e e - - - - - - - e e a e e e -� 1 System Information:
BREAKER(S)SHALLBELOCATEDOPPOSITEFROMUTILITY -----------f 1
NEC 70512(8)(2)(3)(b) 1 1 I-----
SQUARE D SQUARED 1 DC SYSTEM SIZE: 3.78kW
13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY INSULATED LINE
FEEDERS INSTALLED ON PN:D222N DU222RB I- ��------J TOTAL
32W
EXISTING MAIN BREAKER LOAD CENTERAC SYSTEM
IN
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR ---J TOTAL MODULE COUNT: 12
LOADS NEC705.12(A) MODULES USED: HANWHA315
MODULE SPEC#: Q.PEAK DUO BLK-GS 315
14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING UTILITY COMPANY: EVERSOURCE
UTILITY ACCT#: 5197 402 4036
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: 886286422
REQUIRED CONDUCTOR AMPACITY PER RIN DEALTYPE: SUNNOVA
(NEC 690.B(B)(1)1:(15.00.1.25)1=18.75A
PV MODULE SPECIFICATIONS
AWG#10,DERATED AMPACITY HANWHA 315(Q.PEAK DUO BLK-GS 315) Rev.No. Sheet
AMBIENT TEMP:33"C,TEMP DEBATING FACTOR:.96
RACEWAY DERATING=2 CCC:1.00 Imp 9.41 NOTE:CONDUITTYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
(40'.96)1.00=38.40A Vmp 33.46 TO MEET OR EXCEED NEC AND LOCAL AHIDREQUIREMENTS
38.40A'-18.75A,THEREFORE WIRE S1ZE IS VALID Voc 40.29 A #6THWN-2 GEC TO EXISTING GROUND ROD P 1 PV - 3
TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 9.89 B 3/4"CONDUIT W/2-#10THWN-2,1-#loTHWN-2,1410THWN-2GROUND
12.SOA•1.25=15.63A
C 3/4"CONDUIT W/2410 THWN-2,1410 THWN-2 GROUND
AWG#10,DERATED AMPACITY INVERTER#1-SE3000H-USOOOBNC4
AMBIENT TEMP:30*C,TEMP DERATING:1.0
RACEWAY DERATING`_3 CCC:N/A DC AC D 3/4"CONDUIT W/2-#10 THWN-2,1410 THWN-2 GROUND
40A'1.0=40A Imp 8.5 Pout 3000 E 3/4"CONDUIT W/2410THWN-2,1-#SOTHWN-2,1410THWN-2GROUND
40A'-15.63A,THEREFORE AC WIRE SIZE IS VALID Vmp 380 Imax 12.5
F NIO PV WIRE(FREE AIR)W/MS BARE COPPER BOND TO ARRAY
CALCULATION FOR PV O RENT PROTECTION G 3/4"CONDU W/2-116 THWN-2,laf6 THWN-2,1-#B THWN•2 GROUND SOLAR
TOTAL INVERTER CURRENT 12.5.5 A Isc 15 Vnom 240Voc 480 OCPDmin 15.625 R
12.50A•1.25=15.63A 2211 Allenwood Road
->20A OVERCURRENT PROTECTION IS VALID Wall,New Jersey 07719 877-786-7283
U N I RAC
�o U •■
FLASHKIT PRO ten■ NRACFLASHKIT PRO so
���
FEATURING®SHED&SEAL TECHNOLOGY INSTALLATION GUIDE FEATURING 0 SHED&SEAL TECHN010GY
FLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac's patented FLASHKIT PRO IS THE COMPLETE FLASHING AND ATTACHMENT SOLUTION FOR COMPOSITION ROOFS.
SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks.
Kitted in 10 packs for maximum convenience, flashings and hardware are available in Mill or Dark finishes.
With FLASHKIT pro, you have everything you need for a quick, professional installation.
C rb
INSTALL FLASHKIT PRO FLASHING INSTALL L-FOOT ATTACH L-FOOT TO RAIL
I �
PRE-INSTALL •Drive the lag boll down until the L-foot is held firmly in place. It is
normal for the EPDM on the underside of the stainless steel backed
Locate roof rafters and snap chalk lines to mark the installation EPDM washer to compress and expand beyond the outside edge of
point for each roof attachment. the steel washer when the proper torque is applied.
Drill a 7/32"pilot hole at each roof attachment.Fill each pilot hole TIP:
with sealant.
•Use caution to avoid over-torqueing the lag bolt it using an impact driver.
STEP 1 INSTALL FLASHKIT PRO FLASHING -Repeat Steps 1 and 2 at each roof attachment point.
•Add a U-shaped bead of roof sealant to the underside of the flashing STEP 3 ATTACH L FOOT TO RAIL
with the open side of the U pointing down the roof slope. Slide
the aluminum flashing underneath the row of shingles directly up •Insert the included 3/8"16 T-bolts into the lower slot on the Rail
slope from the pilot hole as shown.Align the indicator marks on the (sold separately).spacing the bolts to match the spacing between
lower end of the flashing with the chalk lines on the roof to center the roof attachments.
the raised hole in the flashing over the pilot hole in the roof.When
installed correctly.the flashing will extend under the two courses of •Position the Rail against the L-Foot and insert the threaded end of
shingles above the pilot hole. the T-Bolt through the continuous slot in the L-Foot.Apply anti-seize
to bolt threads to prevent galling of the T-bolt and included 3/8"
serrated flange nut. Place the 3/8" flange nut on the T-bolt and
STEP 2 INSTALL L-FOOT finger tighten.Repeat STEP 3 until all L-feet are secured to the Rail
with a T-bolt.Adjust the level and height of the Rail and torque each
•Fasten L-foot and Flashing into place by passing the included lag bolt to 30ft-lbs.
bolt and pre-installed stainless steel-backed EPDM washer through
TRUSTED WATER SEAL FLASHINGS YOUR COMPLETE SOLUTION CONVENIENT 10 PACKS the L-foot EPDM grommet.and the raised hole in the flashing,into
FEATURING®SHED&SEAL TECHNOLOGY Flashings.lags.continuous slot L-Feet and hardware Packaged for speed and ease of handling the pilot hole in the roof rafter.
THE COMPLETE ROOF ATTACHMENT SOLUTION ]FASTER INSTALLATION. 25—YEAR WARRANTY.
1 ' QUESTIONS 1 ' CUSTOMER SERVICE VISIT UNIRAC.COM1 ' 15) 248-2702 FOR QUESTIONS 1 ' CUSTOMER SERVICE VISIT LINIRAC,COM1 ' CALL (505) 4: 1
' ' ' • ' SOLARMOUNT ���
me
an U N I RAC
' 1 1 1 1 I 1 1 • . 11 1 1 1 "ETTFR DESIGNS
I • • •I 1 ' ' ' 1 i • ' 1 1 1 1 TRUST THE INDUSTRY'S BEST DESIGN TOOL
CONCEALED UNIVERSAL o
Staff the design process for every project in our U Builder online design tool. ENDCLAMPS
It's a great way to save time and money.
BETTER SYSTEMS
ONE SYSTEM-MANY APPLICATIONS
Quickly set modules tluah to the rout on steep pitched roofs_Orient a large variety
of modules in Portrait or Landscape.Tilt the system up on flat or low slow roofs.r Components available in mill.clear,and dark finishes END CAPS INCLUDED
shestooptimizeyourdesignfinancials WITHEVERYCLUDED P
and aesthetics.
BETTER RESULTS �*
CONCEALED MAXIMIZE PROFITABILITY ON EVERY JOB
UNIVERSAL CLAMPS bust Umrac to help you minimize both system and labor costs from the time the job is
quoted to the time your teams get off the roof.Faster installs.Less Waste.More Profits-
UNIVERSAL SELF
unitRAc BETTER SUPPORT STANDING MIDCLAMPS
I25 WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM
Protessional support for professional installers and designers. You have access to
our technical support and training groups.Whatever your support needs.we've got
• 1 i •I YEAR you covered.Visit Unirac.com/solarmount for more information.
^\ Gs
• OPTIONAL lSYS fUtiEM
+ FRONT TRIM W It RA
sys
U-BUILDER ONLINE DESIGN
TOOL SAVES TIME& MONEY
BONDING&GROUNDING Visit design.unirac.com
0 :0;
MECHANICAL LOADING
SYSTEM FIRE CLASSIFICATION
I
I
UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT
UNMATCHED CERTIFIED BANKABLE Ptn 1tl
EXPERIENCE QUALITY EXCELLENCE WARRANTY DOCUMENTATION
TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY
Unuac s technical support team is dedicated to answering Unnac is the only PV mounting vendor with ISO certifications Dont leave your project to chance,Unirac has the financial
questions & addressing issues in real time. An online for 90012008. 14001:2004 and OHSAS 180012007 strength to back our products and reduce your risk. Have
THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING library of documents including engineering reports. which means we deliver the highest standards for fit peace of mind knowing you are providing products of
stamped letters and technical data sheets greatly form. and function. These certifications demonstrate our exceptional quality.SOtARMOUNT is covered by a 25 year
simplifies your permitting and project planning process. excellence and commitment to first class business practices limited product warranty and a 5 year limited finish warranty.
BEST INSTALLATION EXPERIENCE•CURB APPEAL• COMPLETE SOLUTION •UNIRAC SUPPORT ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN
PAGE 51
GREAVES
Grounding Connectors C
POWER DISTRIBUTION TYPE: LI Lay-In Connector / �
CUSIAL CMC* LI-S ground connectors are manufactured from high strength 6061-T6
BUG•BITES_M 90'C aluminum alloy to insure both maximum strength and conductivity. They are
U� CIP dual rated for both copper and aluminum conductors and are electro tin plated
Insulation Piercing Connectors to provide low contact resistance and protection against corrosion. They are
Eliminates need for conductor insulation stripping LISTED designed for use on conduit grounding bushings. The open-faced design allows
No taping required after installation the installer to quickly lay-in the grounding conductor as a jumper to multiple
For copper to copper,copper to aluminum, or aluminum to aluminum applications conduits with no break in the ground conductor.
For use on insulated conductor only
90°C RATING (486B LISTED)
IPC SERIES
NAED CATALOG WIRE RANGE TORQUE CTN EST.SHIPPING _
NUMBER NUMBER MAIN TAP VOLTS BOLTS FT-LBS QTY WEIGHT(Ibs) UNIT Catalog Dimensions,Inches
13110 IPC 1002 1/0-8 2-8 300 1 16 12 2.63 CTN Number •NO. Colt�6f1pe Stud SiZ!*` F #4 1 --W L
13107 'IPC 4006 410-4 6-14 600 1 13 12 1.90 CTN LI-505 1 414 0.22 0.78
13108 'IPC 4020 4/0-2 2/0-6 600 1 25 12 4.08 CTN 78 0.38 07
13109 'IPC 2540 250-1 4/0-6 600 1 30 6 4.17 CTN LI-112S 1 1/0- 14 -�- 0.27 1.17 0.6 1 5
13113 IPC 3540 350-4/0 4/0-10 300 1 25 6 4.17 CTN
13114 IPC 3535 350-4/0 350-4/0 300 2 25 6 1 7.63 CTN
13116 tIPC 5012 500-250 10-12 300 1 25 4 2.85 CTN LI-200S 2 3/0-6 0.33 1.56 0.8 2
13104 'IPC 5025 500-250 250-4 600 1 55 4 4.06 CTN
13105 'IPC 5050 500-300 500-250 600 1 75 1 2.64 EA CAUTION LI 252S 2 250-6 0.33 1.79 0.8 2.2
13106 'IPC 7550 750-500 500-350 600 1 75 1 2.62 EA Use Bug-Bites on
'600 Volts,balance 300 Volts(for 480V grounded Y systems) insulated cable only! C00494353
t Not CSA certified Do not install on bare cable. PWN
-- 114-28 UNF- 28 X.53 DP REF.-
Q /r 0.220 THFtI Q T.4D WLTH[N.077"rMX OF
Dual-Rated % NOT DRILL PAST
AST WIPWIREINAY.LAC•
GUTTER TAP CONNECTORSCIR
_ NOT DRILL PASTWIREWAY.
U� CU9AL I VD_� ),
II1111( III
600V 90'C I HIM I �7s3.ola
High strength aluminum alloy 6061-T6, tin-plated LISTED f .z51
Lay-in designed main conductor remains continuous I IH 1111111 III
Tap parallel or perpendicular to main m .187 t.010
GP SERIES �� [a.75t.251
200 t.015 ,l90#.010
/
NAED CATALOG CONDUCTOR RANGE_ APPROX.DIMENSIONS LN) CTN EST.SHIPPING /// �
CD
NUMBER NUMBER MAIN TAP H W L QTY WEIGHT(lbs) UNIT ////// / `-1/�c8���GG.SSTAIKESS
EW
13117 GP 2' 2-12 4-12 SOL 7/8 5/8 T`/ 24 1.43 CTN --1.0701.015 000201027(I REQ'D)
13118 GP 10 1/0-2 1/0-12 SOL 1 3/4 11/. 12 1.19 CTN ® [27.18 t.381 ASSEMBLE SCREW SNUG
13119 GP 250 250-1/0 250-6 1'1. 11/1a 2'/n 12 2.54 CTN TO BOTTOM
13121 GP 350 350-4/0 350-6 1'/" 17. 2`h, 6 2.75 CTN For copper-to-copper,
13122 GP 500 500-350 500-2 1'/. 11/. TA 6 3.10 CTN
13123 GP 750 750-500 500-2 2 Vh 3% 3 2.5 CTN copper ,
aluminum-to-aluminum II 11
-GP2 has slotted screws. I
Oxide-inhibitor is recommended for added corrosion protection. 600V 900C MARKING 2---\ 11 MARKINd t
.786# 010 CtiC 4-U
Snap-on insulating covers for use with GP connectors For indoor use only \ 150f 006 ' (19.%*.25J u 50-5 CU9AL
GPC SERIES -- t3.81#.15,
MARKING! MARKING 2
NAED CATALOG FOR USE WITH APPROX.DIMENSIONS(IN) CTN EST.SHIPPING \\\\
NUMBER NUMBER CONNECTOR COLOR H W L OTY WEIGHT(lbs) UNIT 18
13137 GPC 2 GP2 YELLOW 1/.. 1`1' 17u 12 0.46 CTN 7�//i ,\\\\\,\ \\\\\\\ ((4.57)) ( 470 \
13138 GPC 10 GP1/0 GRAY 11/. 2'/n 21/. 6 0.36 CTN /7//� /�!p\1\\\ \\\\\ \.11.'94 015 f.005 CA021002S-J
13140 GPC 250 GP250 RED W. 2'/. 3'h. 6 0.40 CTN �h/// 11h\\\\\\\\\\\\ (0.641..L31 FINISH:TIN PLATE CMS-02
13141 GPC 350 GP350 YELLOW 11/1 3'/,E 3`/4 3 0.42 CTN u m 0A1mrh AMIL OF'""r' ca''4`
13142 GPC 500 GP500 BLUE 2'/.0 3'h. 41/. 3 0.46 CTN ° q 11/17/2009 LAY IN LUG LI-SO-S
13134 GPC 750 GP750 ORANGE 2"/m 376. 4% 1 3 1 0.65 CTN M•>/as 000601011
�wca.:vr 1 0 1 6061-T6 ALUMINUM 2.25X
D9•�"F
www.greaves-usa.com CROSS REFERENCE! I�a
11 Heritage Park,Clinton,CT 06413•Phone 860-664-4505•Fax 860-664-4546
TOLL FREE 1-800-243-1130(Outside CT)
Power Optimizer
For North America
Power Optimizer P320 / P340 / P370 / P400 / P405 / P505
O ,
For North America •• '
(typical module (for 60-cell (for high- power (for 72&96- (for thin film (for higher
P320 / P340 / P370 / P400 / P405 / P505cell compatibility) .. Modules)
_ modules)m
INPUT
Rated Input DC Dower ,2t� 340 37+ 4ck, _
Absolute Max,muni�Input
voltage 48 60 80
51 Vih:at Iowesi temperature)
YEAR
O MPP7 Onerat r q Range 8 43 _- - J & � -SO — ' 1
ARRANTY Maxnr un $Ito,t Grt ter'Current 11 1EI'
.13cl
—•_ Maximum DC Input Cunenl _- - 137-
— .-
Maximum ERtc,encv
weighted Efhcienq 98 b 96 n
Ovenroltage Category
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE y
INVERTER OFF)
N
STANDARD COMPLIANCE
EMC FCC Part15 Ua>;,6 !EC6100C-6 2.IEC61000-t,
lately - E 6<04.,Lass II:.afetvl uU'al
RoHS ye,
INSTALLATION SPECIFICATIONS
Maximums Allowed Syste,r
vOltaae t(x)n Vd(
Compatible inverters All So,a,Edge'-ing,e Phase and Three Phase inverters
Dmrnpon5(WxL.H) - 129,19 275,51,6x11 12cl, 15'x33.5; 1?9x1i9x4'+ ,: 129kIr.2•S9
51*6x13 5.1x63. 19 1-1x6.4x23
Weight t,ndud,ng rablest - - 6+O-14 ------- ----- .ISO,t 84;;19 1064/2 A yr i IL
�
Input Connector
Output Wire Type i Cunnectur ----- - Double Insulated.MC4
Output wire tength 095/ 0 i
Input Woe Length. ?16 2 0 52 m/fi
CJperating Temperature Rarlcle .40--85' 40 •185 "C;•r
PV power optimization at the module-level NoteiLonRatmg IP68 'NEMA6P - -- -
Relative Humidity u-100
Rar?u'..ir rn we• f the�r„><l„is,ri+!,isE'.I,y:'„-;?�ryx•.r+tnlr an,,:+-ar.w.
NEC:(' 'Ea,net r•,".� 1—le than e0Y
I Specifically designed to work with SolarEdge I Fast installation with a single bolt fnrr,ne•,.,m,P,t,rt•;,P•DiEat r«4an.nwrEc;;,E
inverters
Next generation maintenance with module Design
I Up to 25% more energy level monitoring Sinle hase Three Phase ''V Three Phase ''
Mlnnnum 5fnnq Length I8
/ Superior efficiency (99.5%) / Meets NEC requirements for arc fault fPoweroptim P400
,zersl P40sP5u5 h _
protection (AFCI) and Photovoltaic Rapid PawniumSter 7i es)ngth sa
I Mitigates all types of module mismatch losses, Shutdown System (PVRSS) — —
Y smil Ie000 with I
from manufacturing tolerance to partial Max,t.,,,n_,Powe,pe(;tr,ng Sfi6OO-us SE11400 525a 60U0 127sa+
shading I Module-level voltage shutdown for installer us) -- _
P Different Length, 1�s
and firefighter safety or Onentatlonsarallel Stnngc n'
I Flexible system design for maximum space Di,„.,ail n,•in9t:; a ritnrrnatl ,etril: h �i;,Ptl4e .r„-tltE:;y ta,lt IEt�nnl_:,:i,�naD,�1
n t ncf40w dl,ma PaO�/P,„1�MIJP! ;F4�,1:F3n�P4.Y),r .4 .q _
utilization Actr,rq wte �iE than lC cpim«r 111wt I.C1 mer.NE C•api7: .mow r ,mment• ,atetyIta),, 1m ie aA ra•it itt�..gun,-mFn!
Fu,$E,4 dKJC'jf432ki.:$it,t t 421CIN' 3 :nnr�nr<;y tr r..+u,vE,f.•r .i Grin0S Pt'r unit Inr:Ed.•:Aliy,ar,p w'*1
n-iaun,yo p—,O,R:•n rt^wrhpn+r:.gong: .�D•r•1,00M
-
nrSE30KU5:4?3�irl! �Er:.Cal'S/xE rK1KU5 to,�v.v•r.1c.+52KAtWFe,gong sne, '-itr+-utaE;onrci,ir.«1Ewriter 1';rnq,D>• n,fo SE666KJS'SE KIOKt.
"'d when the me.imun,Ixtwe,chtteer,ec 11,rtw'en the SPinyr n up 1.-60uw'
solaredge.com solar e
G SobrEtlge lechnolog�es Lid All r,gnts reserved SOCARf WE the Sdartage logo.OVTIMIZED By SOLANEDGf are traelemahs or req,sre.M,raaema.ts of SolarEtlge iecfinologies.Inc
All other tratlemartT me 1-6 herrnn ace trademarxs or their respM owners Date 11/201&W I/rNG NAM Subject,a O.Ne w,Mwn—1l C E ROH S
Single Phase Inverter
wit HD-Wave Tec n0 Ogg/ for North America
Single Phase Inverter SE3000H-US SE380OH-US SE5000H-US SE6000H-US/
• C SE760OH-US / SE10000H-US / SE1140OH-US
with HD-Wave Technology ,,, ,,, ,,,,m
for North America 14211EL1. 11
OUTPUT
SE3000H-US / SE3800H-US / SESOOOH-US / SE6000H-US / 3aoo@240V 6o0o@240V 11400@240V
Rated AC Power Output 3000 5000 7600 10000 VA
3300 @ 208V 5000 @ 208V 1 10000 @ 208V
S E 7600 H-U S / S E 10000 H-U S / S E 11400 H-U S Maxmum AC Power Output 3000 3800 @ 240V 5«10 6000 @ 240V 7600 10000 ! 1400 @ 240V VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
AC Output Voltage Min-Nom-Max.
(211-240-264) ✓ ✓ ✓ J ✓ ✓ J Vac
AC Output V01tagE Min.-Nom.-Max.
` (183 208 229) ✓ ✓ ✓ vac
7`VJ •• AC Frequency(Nominal) 55 3 60 60 5 Hz
LA
Maximum Continuous Output
kk
c ' p 125 16 21 25 32 42 47.5 A
k 8 Current @240V - --— —— -
Maximum Continuous Output
` : n a n
Current @208V `
Power Factor 1,adjustable-0.85 to 0 85
GFDI Threshold 1 A
t
O O Gp: r St I Utility Monitoring,Islanding
prolenion,Country Configurable Yes
Y
INPUT
• solar3,'�[ r}'j�, O O solar rt,D, 0, n DC Power @240V 4650 5900 7750 9300 1180(! 17650 W
i
Maximum DC Power @208V 5100 7751 15500 N
Transformer-less,Ungrounded ve
O Maximum Input Voltage 40 VOL
O O Nominal DC Input Voltage 380 400 1 Vdc
Maximum Input Current @240V- 8.5 10.5 135 1 165 20 27 305 Adc
I Maximum Input Cut rent @208V - 9 13 5 27 Adc
O O O O Max Input Short Circuit Current 45 Adc
_ Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 60OW Sensitivity
Maximum Inverter Efficiency 99 99.2 %
CEC Weighted Efficiency 99
99 @ 240V
Optimized installation with HD-Wave technology 985@208V
Nighttime Power Consumption <25 Vd
Inr "her regional settnis please contact SolaiEdge support
A. ,qhe,rwrem sowte may be,sni,the nverter will limn its ni:w current to the values stated
Specifically designed to work with 0 UL1741 SA certified, for CPUC Rule 21 grid compliance
power optimizers
/ Record-breaking efficiency f Extremely small
/ Quick and easy inverter commissioning directly
from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring
/ Fixed voltage inverter for longer strings I Outdoor and indoor installation
/ Integrated arc fault protection and rapid
shutdown for NEC 2014 and 2017, per article f Optional: Revenue grade data, ANSI C12.20
690.11 and 690.12 Class O.S (O.S%accuracy)
solaredge.com solar=se
powered by
SPECIFICATIONMECHANICAL
DUO Format 66.3in x 39.4in x 1.26in(including frame) -
(1685mm x 1000mm x 32mm)
Weight 41.2 lbs(18.7 kg)
Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology
Back Cover Composite film
Frame Black anodized aluminum �.� (� �•i1040in1
Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells 4t
Junction box 2.76-3.35in x 1.97-2.76m x 0.51-0.83in
(70-85mm x 50-70mm x 13-21 mm).decentralized,IP6700000,00000000 •••-+.+.�.� ""`
Cable 4mmz Solar cable;(+)2!43.3m(1100mm),(-)z43.3in(1100mm)
Connector Multi-Contact MC4,IP65 and IP68,Q.
ELECTRICAL CHARACTERISTICS
• , DUO 300-320 POWER CLASS 300 305 310 315 320
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS.STC (POWER TOLERANCE+5 W/-OW)
Power at MPP' P,., (IIF) 300 305 310 315 320
Q.ANTUM SOLAR
Le MODULE
Short Circuit Current* 6 (A) 9.72 9.78 9.83 9.89 9.94
e Open Circuit Voltage' Vol (V) 39.48 39.75 40.02 40.29 40.56
s'
Current at MPP" Iv (A) 9.25 9.31 9.36 9.41 9.47
Voltage at MPP' VW (V) 32.43 32.78 33.12 33.46 33.80
The new solar module from Q CELLS impresses with Efficiency' r( [%) =17.8 z18.1 218.4 218.7 >19.0
its outstanding visual appearance and particularly high performance MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS.NOC'
on a small surface thanks to the innovative technology. Power at MPP° P,,,. tw) 2zz.3 2z6.o 229.7 z33.5 z37.z
Q.ANTUM's world-record-holding cell concept has now been combined short Circuit Current* I= (A) 7.84 7.88 7.93 7.97 8.02
e Open Circuit Voltage' V« [Y] 36.93 37.18 37.43 37.69 37.94
with state-of-the-art circuitry half cells and a six-busbar design, thus Current at MPP` 1W [A) 7.28 7.32 7.36 7.41 7.45
achieving outstanding performance under real conditions - both with Voltage at MPP` V1" IV) 30.55 30.88 31.20 31.52 31.84
low-intensity solar radiation as well as on hot, clear summer days. IOOOW/m2.25'C.spectrum AM 1.5G Measurement tolerances STCz3%;NOC:5% 800 Wrm-.NOCT,spectrum AM 1.5 G typical values,actual values may differ
D CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY
At least 98%of nominal power during first year.0-A Higher yield per surface area, lower BOS costs, higher power
o -- --- - --- At least1er 93.1max
%of nominaall power u per year.
classes, and an efficiency rate of up to 19.3 /e. power up 1 10 years.2 _
� At least 85%of nominal power up to 5 years.
INNOVATIVE ALL-WEATHER TECHNOLOGY Full
warranties
terms of the QCELL z accordance
ewiththewar warranty
ation
All data within measurement tolerances. e
Optimal yields, whatever the weather with excellent low-light
and temperature behavior. respective country. 10
IRRADIANCE IWft'! Z
ENDURING HIGH PERFORMANCE g
Typical module performance under low Irradiance conditions in
comparison to STC conditions(25°C.1000 W/m').
Long-term yield security with Anti LID technology, CELLS
TEMPERATURE COEFFICIENTS R
Anti PID Technology', Hot-Spot Protect and Traceable Quality Tra.QrNt TOPBRANo
Temperature Coefficient of Isc a [%/K) +0.04 Temperature Coefficient of Vol (%/K) -0.28 8
EXTREME WEATHER RATING `°"°^ Temperature Coefficient of P.,, y [%/K) -0.37 Normal Operating Cell Temperature NOCT [IF] 113 x5.4(45 i3°C)
AHigh-tech aluminum alloy frame, certified for high snow 201 PROPERTIES FOR DESIGN
1 (5400 Pa)and wind loads(4000 Pa) regarding IEC. Maximum System Voltage Vs 1000(IEC)/1000(UU Safety Class II
Maximum Series Fuse Rating [A DCl 20 Fire Rating C(IEC)/TYPE I(UL) a
A RELIABLE INVESTMENT Design load,push(UU' [lbs/I111 75(3600Pa) Permitted module temperature -40°F up to+185'F
O Inclusive 12 ear product warranty and 25 ear on continuous duty (-40°C up to+85°C) 0
Y P tY Y O�ailty Tested e
linear performance guarantee`. Design load,pull(uu' [lbs/M 55.6(2666Pa) 'see installation manual
STATE OF THE ART MODULE TECHNOLOGY QUALIFICATIONS ' INFORMATION
f UL 1703;VDE Quality Tested;CEcompliant: Number of Modules per Pallet 32
Q.ANTUM DUO combines cutting edge cell separation IEC 61215(Ed.2);IEC 61730(Ed.1)application class A
and innovative wiring with Q.ANTUM Technology. APT test conditions according to Number of Pallets per 53'Trailer 30
IEC/TS 62804-1:2015, V /' / SP� Number of Pallets per 40'High Cube Container 26 0
method B(-1500V. 168h) D E l♦ C r Pallet Dimensions It.x W x H) 69.3in x 45.3in x 46.9in
a See data sheet on rear for further c T�us
(1760mm x 1150mm x 1190mm) �
THE IDEAL SOLUTION FOR: information. Pallet Weight 1415lbs(642kg)
Y
NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use
Rooftop arrays on of this product.
0 residential buildings
ilermha Q CELLS Ameria Inc.
300 Spectrum Center Drive,Suite 1250.Irvine,CA 92618.USA I TEL.l 949 748 59 96 1 EMAIL mquiry0us.q-cells.com I AEe www.q-cells.us
Engineered in Germany OCELLS
NOTES:
1.) REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690
2.) STICKERS,LABLES,AND PLACKARDS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.
•
To be located on all DC junction boxes SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
and every 10'on DC conduit -
•,11 •
kCPI R•
NEC690.31(G) (1
NEC 690.56(C)(1)(A)
lot
DC Junction Box • • ' • • • ,
690.56(C)(3) NEC 690.4(B)
.g
ELECIIYCILL IMOCk WIEIIAD
RAPID SHUTDOWN
nrra s.eu,Lw•ro
4ao rna r ouo,®
L .nw aw grwo" J
Service Disconnect SOLAR PV SYSTEM NEC 690.13(B) NEC 690.53
690.56(C)(3)
Soladeck
PHOTOVOLTAIC
SOLAR RAPID SHUTDOWN
Utility ELECTIYCAL SHOCK HAZAM fl S •
WITH RAPID SNUTDONfN
0oN woa,E,\M,Ly
r lE1YN1{d1 NDf"LK Yp
"n n' i o ww,wno,""D NEC 690.4(B)
`n
NEC 690.13(B)
NEC 690.56(C)(1)(A)
If System is Backfed Breaker NEC 690.54 NEC 690.53
NEC 705.12(B)(2)
NEC 690.54 i DC Disconnect
Utility Meter
Socket
yc:x► '
ELEC7/11CA1 SHOCK H&Z11M
00 Mp,Oup,�•l�wW1
• • t'01Dw�E�Et�nl�n
ELICTOWAL SHOf1111.2MD
ro.o,,wwi,n,....• NEC 690.13(B)
NEC 690.54 .�
1 w n.�..owr,•.
NEC 690.13(B) "•
now
i
4" ,
DC Conduit Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box
AC Disconnect (To Combine Inverters)
SOLAR
2211 Allenwood Road
Wall,New Jersey 07719 877-786-7283
www.Trinity-Solar.com
INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
MEHMOOD, ARSHAD-
251 SKYLINE ROAD
SOUTH WINDSOR, CT 06074
41.853518,-72.558189
APPENDIX
CONTENTS
LABELS, STICKERS, AND PLACARDS
EQUIPMENT DATA SHEETS
PERMITS/INSP PAYMENT RECPT# 20909779
TOWN OF SOUTH WINDSOR
1540 SULLIVAN AVENUE
SOUTH WINDSOR CT 06074
DATE: 01/21/20 TIME: 15 15
CLERK: morganami DEPT:
CUSTOMER#: 691972
TRINITY SOLAR
PARCEL:
CHG: BLDPRM BUILDING PERMIT 288 00
AMOUNT PAID: 288 00
PAID BY: TRINITY SOLAR
PAYMENT METH: CHECK
29471
REFERENCE: 251 SKYLINE
AMT TENDERED: 288 00
AMT APPLIED: 288 00
CHANGE: 00
Engineer/License Holder.
ARRAY CIRCUIT WIRING NOTES
LICENSED ELECTRICIAN ASSUMESALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2017 SOLAR MODULES MOUNTED TO ROOF ON 1 ARRAY _ \
12-315W MODULES W/1 SOLAR EDGE P320 PER MODULE
2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB ___ 8"x8"
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
1 STRING OF12 MODULES IN SERIES-390Vmax ------ JUNCTION ---------------------------------------------------------
1
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT F BOX I
TEMP=-16'C "TERMINATED INSIDE INVERTER 1 I
I
3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED I
ON ASHRAE HIGHEST MONTH 2%DRY BULB I
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO I
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= I
33'C
4.)2005ASHRAE FUNDAMENTALS 2%DESIGN O I
TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED
STATES(PALM SPRINGS,CA 1S 44.1-C). FOR LESS THAN 9
CURRENT-CARRYING CONDUCTORS IN AROOF-MOUNTED I
Issued!Revisions
SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING
THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS
(ALL OF UNITED STATES)
5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH PE ISSUED TO TOWNSHIP FOR PERMIT V612M
NEC 690.12(A)THROUGH(D) I NO. DESCRIPTION DATE
6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED I
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC Project Title:
SOURCE AND OUTPUT CIRCUITAS PER NEC 690.41(A)(4) MEHMOOD,ARSHAD-
7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE
I
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
I TRINITY ACCi#:2019-12-396658
POSITIVE CONDUCTORS=RED
NEGATIVE CONDUCTORS=BLACK
NEC 210.5(C)(2) j Project Address:
ov ;
B.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV EXISTING 24� 11� NOTE:
WIRE TYPE RHW-2OREQUIVELANT AND SHALL BE 10120/240V M 100A MAIN BREAKER INTERNAL REVENUE GRADE MONITORING I 251 SKYLINE ROAD
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER CONTAINED WITHIN SOLAR EDGE INVERTER CT 06074
SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24'SHALL SODA BUSBAR SOLAR EDGE FIN.RWND-3D-24D-MB SOUTH WINDSOR,
CONTAIN 5 20 CURRENT CARYING CONDUCTORS AND I 41.853518,-72.558189
89
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN
5 9 CURRENT CARRYING CONDUCTORS.
{ j
9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS All Drawing Title:
OTHERWISE NOTED
I
20.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON LOCKABLE 60A DISCONNECT 60A UNFUSED PROPOSED PV SOLAR SYSTEM
ROOFTOP AND SHALL BE LIMITED TO 12'IF USED FUSED W/20A FUSES DISCONNECT
OUTDOORS 240V 1 240V 10 INVERTER#1 D
,. -lam"., Drawing Information
11.)OVERCURRENT PROTECTION FOR CONDUCTORS e e e e e e e e e e e e > 0
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE —
—a+ DRAWING DATE: 1/6/2020
LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC r � I
DRAWN BY: RTC
705.31 AL
l �� > 0 REV12.)WHERETWOSOURCESFEEDABUSSBAR,ONEA e ^ — — — — — — p Ll L2 N 1 rUTILITY AND THE OTHER AN INVERTER,PVBACKFEEDa V D I S tem Information:
BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY �__ _—0 Lz7�_
e e eAlIg!"11
oNEC 705.12(B)(2)(3)(b) DC SYSTEM SIZE: 3.78kW
EXISTING MAIN BREAKER LOAD CENTER SQUARED SQUARED LJ)L------J AC SYSTEM SIZE: 3kW
----13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY INSULATED LINE TAPS INSTALLED ON PN:D222N DU222R8 L----------J TOTAL MODULE COUNT: 12
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MAIN FEEDERS
LOADS
NEC 705.12(A) MODULES USED: HANWHA 335
MODULE SPEC#: CLPEAK DUO BLK-GS 315
14. ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
UTILITYCOMPANY: EVERSOURCE
A NEMA 311 RATING LmUTY ACCT#: 5197 402 4036
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
UTILITY METER#: 886286422
REQUIRED LONDUCTOR AMPACITY PER STRINGDEAL TYPE: SUNNOVA
(NEC 690.8(B)(1)):(15.00"1.25)1=18.75A
PV MODULE SPECIFICATIONS
AWG#10,DERATED AMPACITY HANWHA 315(Q.PEAK DUO BLK-G5 315)
AMBIENT TEMP:33'C,TEMP DERATING FACTOR:.96 Rev.No. Sheet
RACEWAY DERATING=2 CCC:1.00 Imp 9.41 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
(40'.96)1.00=38.40A Vmp 33.46 TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS
38.40A'-18.75A,THEREFORE WIRE SIZE IS VALID Voc 40.29 A #6THWN-2 GEC TO EXISTING GROUND ROD P 1 PV 3
TOTAL AC REQUIRED CONDUCTOR AMPACITY ISC 9.89 B 3/4"CONDUIT W/2-1110 THWN-2,1410 THWN-2,1-410 THWN-2 GROUND
12.SOA•1.25=15.63A
C 3/4"CONDUIT W/2-#10THWN-2,1410THWN-2GROUND
AWG#10,DERATED AMPACITY INVERTER#1-SE3000H-USDOOBNC4 =
AMBIENT TEMP:30'C,TEMP DERATING:1.0 D 3/4"CONDUIT W/2-#10THWN-2,1-#lOTHWN-2GROUND -
RACEWAY DERATING 13 CCC:N/A DC AC
40A•1.0=40A Imp 8.5 jPout 130DO E 3/4"CONDUIT W/2-#10THWN-2,1410THWN-2,1-#10THWN-2GROUND
4OA'-15.63A,THEREFORE AC WIRE SIZE IS VALID Vmp 380 1 Imax 112.5
F #10 PV WIRE(FREE AIR)W/#8 BARE COPPER BOND TO ARRAY
CALCULAT URRENTPROTECTION VIsoc c 480 OCPDmin 15.625
SOLAR "
TOTAL INVERTER CURRENT:12
15 jVnom 1240 G 3/4"CONDUIT W/2#6THWN-2,1#6 THWN-2,1-#8 THWN-2 GROUND
12.50A'1.25=15.63A 2211 Allenwood Road
—>20A OVERCURRENT PROTECTION IS VAUD Wall,New Jersey 07719 877-786-7293
AJ6„
I
V
•i fl u SU'-Gills lt, ;,S at':tf�.•
Uns c_ru I or alterations to UN
:pPWS of tnc Propns:d Uml�;inu
erected at
Strue,
---�— in application nnf
together with cr-r�i� t ,vlth all zone^g
filed with PI'° .a°� t .r.lcrs as shall )k
,utlding •11.,% 1 is�'s •j ,f,rilg gender.I
Issued Dy tno 'Id'�+ p"f' rt Duildi� a
,f this IPPilcotion end final is i,.,rce of a
oermit.
signed condition that
his plan is .-IpPr^.,,,.A t,af•�t to tl.,• shalt G1
•rdcrs a..d ofdlr-aces r.rll t,r t'•:Iang
pll,d rth.
,,Or Y AEProved
,.se filed with,
C 1wrtL
•It1A rn� InSi^Or�
-y
NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS
'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE UNIRAC CLAMP
NEW PV SOLAR MODULE,TYPICAL (REFER TO SPEC SHEET FOR DETAILS)
(REFER TO EQUIPMENT SCHEDULE
FOR SPECS AND QUANTMES) SOLAR MODULE SOLAR MODULE
♦ ♦ �__ NEW MOUNTING FOOT/ATTACHMENT
POINTS,TYPICAL (REFER TO UNIRAC"L'FOOT UNIRACRAIL fl0
ENGINEERING LETTER FOR SPACING /
AND DETAILS) f0 (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS)
NEW UNIRAC RAIL.TYPICAL
TO BE MOUNTED PERPINDICULAR TO UNIRAC FLASHING EXISTIN
STRUCTURE(REFER TO UNIRAC (REFER TO SPEC SHEET FOR DETAilS)� (REFER N ENGINEERS LETTER FOR SPECS) C
SPECIFICATION I DATA SHEET FOR `` G ASPHALT SHINGLES i �
DETAILS) /
NEW O TYPICAL(REFERTO UNIRACSPECIFICATION/ S.S.LAG BOLT APOC SEALANT SOLAR MODULES SHALL NOT /,/ I I�I \\\
W. DATA SHEET FOR DETAILS) EXISTING RAFTER EXCEED PEAK HEIGHT.
NEW MID CLIP,TYPICAL (REFER TO ENGINEERS LETTER FOR SPECIFICATK)li
(REFER TO UNIRAC SPECIFICATION/
DATA SHEET FOR DETAILS)
nATTACHMENT&CLIP DETAIL PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF nHEIGHT FROM GROUND LEVEL TO PEAK OF ROOF '
SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE
ARRAY SCHEDULE
Issued/Revisions
—� 1
PI WLAO 0T9WN5 1PRAK11W 1/4r1m0
w LINE) i
BACK < ' (PROPERTY
NO. DESCRIPTION DATE
o BACK
Project Title:
ROOF ACCESS
GROUND ACCESS I MEHMOOD,ARSHAD-
TRINITY ACCT#:2019-12-396658
I ' Project Address:
ROOF ACCESS ROOF ACCESS AC 251 SKYLINE ROAD
1 Dc I SOUTH WINDSOR,CT 06074
D LID I 41.853518,-72.558189
EP M I I Drawing Title:
I
IPROPOSED PV SOLAR SYSTEM
I111A �
Drawing Information
I ® DRAWING DATE: 1/6/2020
DRAWN BY: RTC
ROOF ACCESS I REVISED BY:
1 �
System Information:
DC SYSTEM SIZE: 3.78k W
AC SYSTEM SIZE: 3kW
TOTAL MODULE COUNT: 12
GROUND ACCESS I ' MODULES USED: HANWHA 315
I MODULE SPEC#: C PEAK DUO BLK-GS 315
FRONT UTILITY COMPANY: EVERSOURCE
UTILTY ACCT#: 5197 402 4036
NOTES: FRONT I UTILITY METER C 886286422
1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE DEAL TYPE: SUNNOVA
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. I '
2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION.
3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. -- Rev.No. Sheet
4� AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(q
5j ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
6J ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. �, I —
SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE V 2
INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSEO PV DISCONNECT TO BE INDICATES NEW PV ONLY SUBPANEL
CITY SPEC#
R� ARRAY SCHEDULE FOR MORE INFORMATION FU7D INSTALLED OUTSIDE (UTILITY ACCESSIBLE) SP TO BE INSTALLED 12 HANWHA 315(O.PEAK DUO BLK-G5 315)
INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE3000H-USO00BNC4
M INDICATES EXISTING METER LOCATION El
INDICATE PANELS THAT USE MICRO INVERTERS.
ROOF 1 REFER TO EQUIPMENT SCHEDULE FOR SPECS.
MODULES:0 OTHER OBSTRUCTIONS
PITCH:27' INDICATES EXISTING ELECTRICAL PANEL INDICATES NEW PRODUCTION METER TO BE
ORIENTATION:58' EP LOCATION: INSIDE P INSTALLED OUTSIDE. SOLAR
ROOF
MODULES:12
PITCH:23 INDICATES NEW FUSED PV DISCONNECT TO BE INDICATES NEW INVERTER TO BE
ORIENTATION:238 a INSTALLED INSIDE INSTALLED OUTSIDE. 2211Allenwood Road
'4 REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 877-786-7283
INSTALLATION OF NEW SKYLINE ROAD.
ROOF MOUNTED PV SOLAR SYSTEM ` �4 �s
_.4
251 SKYLINE ROAD ,4
..
SOUTH W I N DSO R, CT 06074 �
f e
iiyr� y �
Issued/Revisions
P1 ISSUE D TO TOWNSHIP FOR PERMIT 1/6/..
VICINITY MAP SITE NO. DESCRIPTION DATE
SCALE: NTS Project Title:
MEHMOOD,ARSHAD-
TRINITY ACCT#:2019-12-396658
Project Address:
251 SKYLINE ROAD
SOUTH WINDSOR,CT 06074
41.853518,-72.558189
GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX
1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES Drawing Title:
RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS
EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLT AMPERE PV-Z ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM
DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO WATT
CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM
INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE
2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.THIS SET OF PLANS SHALL MCB MAIN CIRCUIT BREAKER AP APPENDIX Drawing Information
RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE NOT BE UTILIZED AS CONSTRUCTION MOP MAIN DISTRIBUTION PANEL
EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE DRAWINGS UNTIL REVISED TO INDICATE MLO MAIN LUG ONLY DRAWING DATE: 1/6/2020
DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. 'ISSUED FOR CONSTRUCTION'. MTD MOUNTED DRAWN BY: RTC
IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR 16 ALL INFORMATION SHOWN MUST BE MTG MOUNTING
3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE CERTIFIED PRIOR TO USE FOR N NEUTRAL REVISED BY:
NEC NATIONAL ELECTRICAL CODE
RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CONSTRUCTION ACTIVITIES. NEC NOT IN CONTRACT
UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE NO# NUMBER System Information:
COMPONENT AND INVERTER MANUALS ARTICLE 690 8 705.
PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS ABBREVIATIONS NTS NOT TO SCALE DC SYSTEM SIZE: 3.78kW
CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: 3kW
ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL AMP AMPERE P POLE
POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AC ALTERNATING CURRENT PB PULL BOX TOTAL MODULE COUNT: 12
THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AL ALUMINUM PH 0 PHASE MODULES USED: HANWHA 315
AF AMP.FRAME PVC POLY-VINYL CHLORIDE CONDOR
SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND MODULE SPEC#: O.PEAK DUO BILK-GS 315
4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AFF ABOVE FINISHED FLOOR PWR POWER
CE
MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFG ABOVE FINISHED GRADE CITY QUANTITY UTILITY COMPANY: 5197EVER 402 40
CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AWG CONDUITAMERICA WIRE GAUGE RGS RIGID GALVANIZED STEEL UTILITY A ET#: 8862 6422 6
ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL C CONDUIT (GENERIC TERM OF JS SOLID NEUTRAL UTILITY METER#: SUNNOVA
SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING RACEWAY,PROVIDE AS JSWBD SWITCHBOARD DEAL TYPE: SUNNOVA
COURSE ON SITE. CONDUCTIVITY CHECKS. SPECIFIED) TYP TYPICAL
CB COMBINER BOX U.O.I. UNLESS OTHERWISE INDICATED
5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND
THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CKT CIRCUIT WEATHERPROOF
CT CURRENT TRANSFORMER XF XFMR TRANSFORMER
MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CU COPPER -72 MOUNT 72 INCHES TO BOTTOM Rev. No. Sheet
TOGETHER AND THAT EACH OF THE OPERATION MANUAL. DC DIRECT CURRENT OF ABOVE FINISHED FLOOR OR
INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC DISC DISCONNECT SWITCH GRADE P 1 P V 1
IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DWG DRAWING
6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE EC ELECTRICAL SYSTEM INSTALLER
BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND EMT ELECTRICAL METALLIC TUBING
CONVENTIONS OF THE NATIONAL OWNERS. FS FUSIBLE SWITCH
ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND FU FUSE
WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE GND GROUND
GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL GFI GROUND FAULT INTERRUPTER
7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: HZ FREQUENCY (CYCLES PER
INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL
'UL'LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, SECOND
311 OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS TH In ity
GENERAL NOTES
SOLAR
IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A',PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY OF EQUIPMENT. 2211 Allenwood Road
Wall,New Jersey 07719 877-786-7283
.Hr'y. , ,�w..w�r�o.r� �..��.�.... .w..«.ww...�.+.a+u.�yl.'• }3�S�ti
110
IN
ri01
Co
LC
t y' f
?
1
Ou
7.
Z
IV z
LU Cl
U W ..fJ• Q
41
Si
a a Q
o s• ►-
rr
ILI
r' Yy^r•ri::t. l rrti _ ,-. + J 1 � w O. .�: .i +j1
Y 7 �Y I•^ij 11� ` � f�l ��: 1
LEI 4 t`I< t �101.t1}ifT�: (1"1:'1 w wCL
#: ( � T �i JlY � d T cz UI.
'` ,�1f)'tl<77J07cI.NT 'IfL1:M V iMi Rr-DJ A.T.'�fiMONd ::11IT. ',"ta.T':d.•L•M a �.
I:ITTI M'()21J -1.110 V-T1MI:N74 M :•RIt' 'RIM, IL (UN `;rJJ,l rTNq-121
01111107. AO :Tt 10I. V IO IA (X 1 :*IV c}?L1}1]. .M U, �."II 1I'I .x rw u nm
r10 JLUI J.:-M'LT.S tIaM 110 n-A( 1l:MT.L M MI C 1 Q 1 E1Y)11.3 K
(L•1LU. a i 'RRI sau(ni TR f.;r» T I L Par ND I SS IS Al l '1Vf}.L'n' :10 ii tt
;'•si S'fitIll CNIV SINI'1 TLLIT, ftNuis :TSItRi:Iiuo S TItJI �INUT. (PTV ' "IV11 1L/
�i ?I Il1CX)•'WD'UJf1J:U '.-Iil<t .10 ;KW 'MIT, 30 Z-V STM Af) SCIINTTN1W :111T,
EI;IIitm-S.'umcf..) :(dv tXrmal t3"1(ns SIIn mifn:—31 M\Yv .'iClt rr.l '111t Q. Ar
; JM t.,(RIV (UIfXI?L`) :IIiI. tJ(kif} 1i 1�1'Tt'flT.'7v S`.'h+ K�1?lf}c SZ1I}, .L~IIIL
"-"'Nl:IT.(i'i ,j M(P 19111 '*,' '00 d.SfDLL T? it-Nril 'RI"l T"Al (RIRIU-M, :)d7 0 cx
''. `"Al IUTOM) ;,TLLU S,MKILLV ,j11.)LIX-RII'x) nl MIT?',;) MRRY, 1
OCT 14 1992 Dt
South Windsor
T" t BUILDING DEPARTMENT
i a
C
A7�
i✓-iOIEICATION OF ZONING Ct jvi�!6.
/'� ' Proposed building(s), use(s) and/or structu; .
as shown on this plan appear(s) to b ,
conformance with current SoLitil UI,'i,;,
egulations. Variances and spacial exCai;:
nay apply.
)ate
Zoning Enforcement Officer.
ra
'iJ t Z
O � h
d
N K(lea ti i
' 2• ?B;� vJ
p e. H ra
_ !
Q X-S
a.,
�.,.EST•E.P C/.E�C.C�
NO ZONING VIOLATIONS IF HOUSE `S
�a
ERECTED AS SHOWN AND STAKED
I HEREBY CERTIFY THIS MAP TO BE SUBSTANTIALLY
PROPERTY OF CORRECT AND IN ACCORDANCE WITH CLASS A- 2
OF CODE OF CONNECTICUT TECHNICAL COUNCIL `�p4 CON,yECt/
M 4�"' car
SKY VIEW
0
DEVELOPMENT CORP. W. M. ALFORD 4o 216S
CIVIL ENGINEER
WINDSOR, CONN. °�� geGIsILit
f48in�et L��
LOT 70 SKYVIEW SOUTH WINOSOR,CT SCALE: 1 IN. -- 40 FT. DATE /Ml /9. s7st
� � v N
-� 11 411
/9 Q
�1Er5 c D
N h 0
w 8 V) o
-4
NO ZONING VIOLATIONS IF HOUSEfM;`
ERECTED AS SHOWN AND STAKED. ,,,
I HEREBY CERTIFY THIS MAP TO BE SUBSTANTIALLY
PROPERTY OF CORRECT AND IN ACCORDANCE WITH CLASS A- 2
OF CODE OF CONNECTICUT TECHNICAL COUNCIL. ��QF CONNEC,t/
� N AA Ale,
C'
SKY VIEW � w � 90 �,
0
DEVELOPMENT CORP. W. M. ALFORD No 2163
CIVIL ENGINEER
I
WINDSOR. CONN. °�i �f6�lERE� sla
f4�in�et h�
LOT 7D SKYVIEW SOUTH WINDSOR,CT SCALE: t IN. 40 FT. DATE
t�
:G
M
� �� � � • y � � 8 �`� iG G23So.f'r. a ��
_ ♦ � � ii
58s A oID
,
OIts
FOd�/OAT/O.✓ Ci5/E�'.�.EO f..�G ST�� �I��.G..� -
NO ZONING VIOLATIONS JJ'
I HEREBY CERTIFY THIS MAP TO BE SUBSTANTIALLY
PROPERTY O F CORRECT AND IN ACCORDANCE WITH CLASS A- 2
OF CODE OF CONNECTICUT TECHNICAL COUNCIL. `��F Ct�lYlyf�,l
SKY
W. M. ALFORD
D EVELO PM� T C® R P' CIVIL ENGINEER
WINDSOR. CONN.
,LOT 7D SKYVIEW SOU TA H WINfOSOR CT. SCALE: I IN. = 40 FT. DATE IP7-�e�
i °°
'a � �i v 1•
4�, .,►
Mg
?rtY' 1s. rfr Os"
' b1
< u
:'��.� ma's'^•(7 / N T U t.
WI_ I�f
w z r-
r a w LaC
LL.
n) ` try u 1 S u r
t� Si, La w
4 ¢ u J
7
+5•• — �'� •ter•�'/r r S�I ) M \ � U.
J
CL
p rVOIS :1 C{1T, t IT, `i-T11T0 : -Nq :T IT.
io tiOUL Ilk., 'IfL1;i M v kmi T1r-D1Vo,nf I. T:II OM,T :.I11!. ::XdI T.7.a.-L•M `- a
`
dam' �2><7 ZI 210 T1LTi:[:,'tra Clf] :R!!' :R�"TI 11. (Tt:t' :T`V?7,T A'1,�r
^'4t•• _ .01TLWOZ•4T0 SlJOI VIDIA (14 .4V ;K-1111, 1\117. :It+'7(fTTf1tI
.,
rlU�JiTZL `I.:.[M'I S i K.kT11 210 YJnn 1 r)V3'L'X•rT .W I (x1 cT rf
: ,,►'•� S`v (L•1J.�OC112IE'. �.';)t1I C1'tIllfi 3•it'S :Ts 1t I:II' 1101; 1:T;;Q i '1�JiL�`' :I(? o z ''t
t'+-S'ltv'I'I Cllti''�{ S:INI"1 Tui.,L �I1hY7H:a :ISIl•RI nuo 5:-.•1 ain `I' 1LL (PAT �"-,xri
,n T
) 1IMM:'A'JI.tZML 3111 a0 .'KICX) MIL 30 Z-d SSt'D L40 SCRit'CLRVIS :41IT. z
L}•� T•�yu� ��TT TT��\77��y�r�\ `}� yyr� m �.7�7•�7� �•, �y��/y�} rn _ �• 0
fql j J t a� n-ard o -It7 K t AJS0.'11� tmr; .7.1�n.,-;Dlfn, 1�/ aTv .7t1:• ria m 1L '77
'."�t '�k1i�..,(L'IH (R1fXJ?IJ �11L NCklfl �d1•i �'TI;'RI.'� S`JF! 1�'Tl�?Ifl� ST11L .L�'fIL N u �,�,� >.''_'�: f.
NI:tLL�i '� :1.�T(AI�{I2I >; .� 1:Tf a '� ima 'It'IJOIJ�rT CPT0.3T�m. ' r:x1l
A
' <'r.>1�1(U� z.U1�(VfYI '�'ti_T.1. s_.�,IN?l(1Lty .tt�laT:7lt?t•�� C11 �.n.T?"� ,<<�1�T 1 .. U, •:;=� ,
9
JUN 2 7 19%
South Windsor
BUILDING DEPARTMENT
TO ME 6UROINJ Ot,; ;t),.
Thtt eertilied that this p,..,, n s are true 1
-pi s o1 the proposed building or alterations to be
erected at
trcet
together with amendme t sta+ d in application and
riled with plan and I a¢r , in y —h all zoning.
Building and state laws .vid ord:rs as shall be
issued by the Building . : during pendency
.f this application and find issuance a builrila
permit.
n
Signed
!his plX Is approv,d suer'=: to the condition that
orders and ordinances regulating building shall by
„nmpirod -,in.
r.onditionaliy Approved These tiled -61:4
fling I spocIf Cie*
��
CERTIFICATION OF ZONING COMPLIANCE
ProposFd building(s), use(s) a;id(or structure(s)
/ as sn,;,,,n on this plan appear(s) to be in
C� x
� conformance >;r,th current South Windsor
regulations. Variances and special exceptions
sec l� may apply.
Date ���
6/d 719 —
Zoning Enfnrcement Office,
t:L. 1'ii'Y 1U ouiLu: rICU1' KI'Wiq;LY'.-; TITLE Wi:?:'l:li'i :ll:tlf
1 w D .0 r +t� •, , , r )' t
LII:: `[1t°,�all��raD fr►1 t\�C:t\I. Imo',►\k� f. TRU. W. :t I.ILI(.nF1' ta. ! ,r1r.Iri
~- o 'LI ii ► MIS :iUI(VL:f i�t'>:•i :(;i1:�,LLY !V-I)L UPIA4 'll ff" l 1011 a) AI iL' 'Il"1` IT
1 u ? ��+li Ilia i%J�i i1�J c1t`� :11ii:�l11 1:I Il'S Il ic"l WY.1J1":i i (PRI T.Ci'• •t�I'111I:!
'll:i: S'l%tU AIZD5 OF CL=..S A-2 OF IhE CX DE OF THE '1'1•ir-TI.Cid, (: INCIL'
cIiD IILAT, Ui�1.I :� (1i11LIUIISI: ::11171,tCI, TITLL LIl1S tN.i1ll 1.1:t�.S5 t
Ii>� WILDLN;S alb: IIaCIiI - AS
i:rb-W [7Ui E:•k.rC:=ill GvEa OI: Ull:v S-Iluu:T, 'I'IZT-E oil
-r Z i UILDLX, Li `ZiV1'47i4Z: ARE NO VIOIAl'ICX4S OF MILNG I
OIc cummmu I s
YMI A (:1L:EVIA. ltL;I EC—fl(Y. CAN
Ili: St` -E UlitM '&Vi 'llEX;L :; iadl i„iD DEl'I('1L:D ILF.I:Uii j
---Y m ^� '_� <`-_3 �a;�iufiJ :iU1:ti::YUR �7c),"Jl� 2 Lb
� 1
L "_ I _ ••
•n
rn
w t
t ---1 �� .a w
� " �
Ln
rn
-� ^
r rn G o .�n
I
i :• m ao i y m 4-0�-
�\Z_
-1
r c°
to y 1
I C
Jd
oz
I Z �
1�
D
OCT 2 5 1988
South Windsor
BUILDING DEPARTMENT
fO THE BUILDIHS OUT. SOUTH
his certified that this plan and specifle3tl s are tnu
=opies of the proposed building or alterations to k
-acted at
A-e
!tree+
together with amendments stated in appfication am
tiled with plan and I agree to comply with all zoning.
Building and state laws and such orders as shall bg
Issued by the Building Department during pendencv
'f this application and final Issuance of a bulldinp
permit.
Signed
This plan 19 approved subject to the condition the,
arders and rrdil-nces regulating building shall be
•ion-,phcd .ith
ondlt�io(nalllllyy Approved These filed with
Bullding Inspector Cleru
�•t• �0 3��� IVd. 173 ZZ
• 1,4 d
SAP
tz
H
a ti
• 7i ti ti 0 0
C� a, o
zG 13 �9
14 so.oa
r aq •
-�o�r�✓os�r�a.✓ �:s�Ec.�.Eo �„.f$T.EiP �'/��'.��
NO ZONING VIOLATIONS
1 HEREBY CERTIFY THIS MAP TO BE SUBSTANTIALLY
PROPERTY O F CORRECT AND IN ACCORDANCE WITH CLASS A- 2
OF CODE OF CONNECTICUT TECHNICAL COUNCIL
SKY VIEW �V.
W. M. ALFORD
DEVELOPMENT CORP. CIVIL ENGINEER �f, No. 216S
WINDSOR. CONN. °�� gF6isIE1lEV V°IN
a
F�Qintar b
LOT 7D SKYVIEW SOUTH WINOSOR,CT. SCALE: I IN. = 40 FT. DATE /97'!�<
i
t
701 ID
>. LadHq �
CAI e.
An
-S;.
.�e�.✓o.9r�ov "s-fc.�-.Fo �.fST.E.E� �'/��'.0�
NO ZONING VIOLATIONS
1 HEREBY CERTIFY THIS MAP TO BE SUBSTANTIALLY ;
PROPERTY OF CORRECT AND IN ACCORDANCE WITH CLASS A- 2
OF CODE OF CONNECTICUT TECHNICAL COUNCIL. ��pE COWH£�l
P N M 1 le,
SKY VIEW
0
W. M. ALFaRD No.
DEVELOPMENT CORP.
r„IVlL ENGINEER F
WINDSOR. CONN
4ineer
LOT 7,6 SKYVIEW SOUTH WINOSOR CT SCALE: i IN. : 40FT. DATE 'S 1975e
Electric # APPLICATION FOR BUILDING PERMIT
Plumbing#
HVAC# 51 S Kv) Ifl 'L Rd Date:
Sprinkler#
FINAL APPROVALS Estimated Cost $_ (O _
Building COMPLETE RED BOXED AREAS Permit Fee $
Engineering Occupancy Fee $
Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $
Appr.forCO. SIGN ON REVERSE SIDE t
Total Fee $ 90• `
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant ,AAj SrAQy_ Location of Work -e 12-PA Lot No.
Applicant's Address Tel # �_�^�D�'-3
Town k('e I ]r Zip_PL41t) Lic.# U 355 -0
Owner AA Sha a me MOo Architect
Owner's Address (5\ Si(.qW�2 Architect's Address
Zip Zip
Sq. Ft, New Area: 1 st FI. 2nd FI. 3rd Fl. _Total New Area
Purpose of this permit A :Ro y
City Water J Well J Septic System J Sewer J
Ins: HO S Area Basement Garage
Approved by �T7��_Da_tei_ Use Group Construction Type
X-A \Oo I u-� Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building and use is allowed.
Signed_
I hereby apply for a Certificate of Occupancy for the work described in this plic tion for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
INSPECTION FIELD SHEET O1/13/21
Printed by Middleton, Morgan 11 36 26 ►
INSPECTION: 126174 FINAL PERMIT:
STATUS:
APPLICATION: 202000107
LOC: 251 SKYLINE DRIVE
SOUTH WINDSOR
PROPERTY ID: 83100251
OWNER: MEHMOOD ARSHAD&
CONTRACTOR:
REQUEST BY:
PROJ DESC: INSTALLATION OF 12 ROOF MOUNTED SOLAR PANELS (3 78 KW)
WORK ORDER:
INSPECTOR: WEAR RESULT: PASS
REQUESTED: PRIORITY:
SCHEDULED: 03/31/20 PM COMPLETED: 04/01/20
UNPAID FEES 00 Date Time
MILEAGE: 00 TIME: TRAVEL ONSITE
COMMENTS
ALL INSPECTIONS:
INSPECTED INSPECTOR RESULT INSP DESCRIPTION
04/01/20 WEAR PASS E010 ELECTRIC FINAL
Electric# APPLICATION FOR BUILDING PERMIT
Plumbing# 251 Skyline Drive
Date: f O —/?-c�/
HVAC #
Sprinkler# No. 28273
FINAL R Estimated Cost $ d oo- �^
Buildin 1 0 Jf COMPLETE RED BOXED AREAS Permit Fee $ ,�
Engineer' TYPE OR PRINT ONLY Occupancy Fee $
Affidavit SIGN ON REVERSE SIDE``
Appr.for CO6t/
Total Fee $TO BUILDINGMENT,TOWN OF SOUTH Wt DSOR,CT (Additional Cost) $
The undersigned hereby applies to do work according to the following specifications:
Job Location Z �y �� Lot No. Side of Street Zone
Applicant w ti T vf- 0-j,,1 C t C- Tel.# SS 0
Address 1 N I I+^L r ,h Af r Zip Lic.# S 7 a g a 7
Owner &d V f J Ode h er4j P i 4,:� Address oZ t Dr-
Architect
— .
Architect Address
So,Ft.New Area: 1st FL 2nd FL 3rd FL Total New Area
#Rooms #Lavatories #Bathrooms #Garages
��
Purpose of this permit: /4(0s�.Oe g /2r D ��:jam AC--
-
City Waw ❑ Well ❑ Septic System ❑ Sewer ❑
Ins. H.O. S.P. V Cert. Area Basement Garage
Approved by Ate_ Date -l1 Use Group Construction Type _
Revised 9/01
• I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans x specifications of the Building for which this
permit is asked,and agree that this building is to be loc ed the proper disxance from all street lines,side yard lines,and required
distances from all other zones and is located in whic t ng use is allowed.
Signed
I hereby apply for a Certificate of Occupancy , t�',rin this application for the permit.
Signed
DO NOT WRITE BELOW THIS L NE
INSPECTION COMMENTS
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-28273-B 2,000
BO1 FOOTING 10/31/01 GRM A W/CONTRACTOR-20 PIERS
B10 FINAL 12/05/01 CJD D GUARD RAILS NOT 36"
B10 FINAL 12/01/06 JFF A RAMP LESS THAN1/12 HANDRAIL OR
i
2000030 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 01/30/2020
GIS ID: 83100251 FEE: 90.00
MUNIS APPLICATION# 202000107 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: TRINITY SOLAR ADDRESS: 251 SKYLINE DRIVE
ADDRESS: 7 MCKEE PLACE OWNER: MEHMOOD ARSHAD&
251 SKYLINE DR
CHESHIRE,CT 06410
DESCRIPTION OF WORK: INSTALLATION OF 12 ROOF MOUNTED SOLAR PANELS(3.78 KW)
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITII THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
1/30/2020 1:44 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1600366 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 06/16/2016
GIS ID: 83100251 FEE: 105.00
MUNIS APPLICATION# 201600564 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: MEHMOOD ARSHAD ADDRESS: 251 SKYLINE DRIVE
ADDRESS: 251 SKYLINE DR OWNER: MEHMOOD ARSHAD&
SOUTH WINDSOR,.CT 06074-1377 251 SKYLINE DR
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: VINYL SIDING.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
6/16/2016 11:10 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
2000024 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 01/30/2020
GIS ID: 83100251 FEE: 198.00
MUNIS APPLICATION# 202000107 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: TRINITY SOLAR ADDRESS: 251 SKYLINE DRIVE
ADDRESS: 7 MCKEE PLACE OWNER: MEHMOOD ARSHAD&
251 SKYLINE DR
CHESHIRE,CT 06410
DESCRIPTION OF WORK: INSTALLATION OF 12 ROOF MOUNTED SOLAR PANELS(3.78 KW)
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
1/30/2020 1:45 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE