Loading...
HomeMy WebLinkAbout25 RED ROCK LN Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# Date: � ��2�t Sprinkler#_Y Estimated Cost $ �0 FINA Pl; OV L Permit Fee $ Buildin COMPLETE RED BOXED AREAS Occupancy Fee $ Engineeri TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit Appr.forCO. SIGN ON REVERSE SIDE A Total Fee $ 60 TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: 1 Applicant Location of Work o �q� Applicant's Address 29P C,k Tel # > Town_ Zip D d0 7 c4 Lic.# Owner _ rJA41 air e Architect Owner's Address 2 Qo(,k= /i Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area _ Pu ose of this permit ✓n" ^� r le.. YQ V 0 k,) a L Gt_ -rr VV% 4" City Water Well 'J Septic System J Sewer, Ins: HO V SP Cert. Area Baseme Garage Approved by Date `l' Use Group Construction Tye I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be local d the pr er ydistnce rom all street lines,side yard lines,and requjred distances from all other zones and is located in whicVt buildin and s allowed. . Signed I hereby apply for a Certificate of Occupay�cy r th/wo, desc a in this application for the permit. Signed ! DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS INSPECTION FIELD SHEET O1/22/19 Printed by Acevedo, Maria 09 26 38 INSPECTION: 113108 FINAL PERMIT: STATUS APPLICATION: 201900050 LOC: 25 REDROCK LANE SOUTH WINDSOR PROPERTY ID: 75500025 OWNER: YAO YUANHG & CONTRACTOR: REQUEST BY: PROJ DESC: PERMIT FOR WORK PREV DONE TO FINISH BASEMENT SPACE INCLUDES WORK ORDER: INSPECTOR: DOUG RESULT: PASS REQUESTED: 01/18/19 PRIORITY: SCHEDULED: 01/18/19 COMPLETED: 01/22/19 UNPAID FEES 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION O1/18/19 DOUG PASS E010 ELECTRIC FINAL O1/18/19 DOUG PASS PO10 PLUMBING FINAL APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT .1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE)860-644-2511 EXT.230 DEPARTMENT DECISION PERMIT NUMBER: APPI JET f�Y: APPROVED: BLDG.PERMIT NUMBER- DATE � R LOCATION OF WORK: 4u C- (`— APPLICANT: OWNER: TYPE OF STRUCTURE: / J o NEW BUILDING NAME:�i �7 l�' I /jr,- /G NAME: ❑ADDITION PHONE NUMBER dLQ�"Sf3 O(p(ll PHONENUMBER: E7QSTINGBUILDING ADDRESS:S( � C fU J �y�, ADDRESS: r TYPE OF USE: RESIDENTIAL, o COMMERCIAL PLUMBING INFORMATION: FUR11M DESCRIPTION OF WO TYPE OF INSTALLATION: ! _ V y�J c NO.OF TOILETS:_�STYLE: NO.OF BATHTUBS: l L V�T (/LI('q S /UU l PLC n `— NO.OF SHOWERS:_�NO.OF LAVATORIES: l NO.OF CATCH BASINS: NO.OF FLOOR DRAINS: ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY WINDOW? DYES ,dNO, ESTIMATED COST: SIZE OF WINDOW: SITE OF DUCTS: ` SEWER OR SEPTIC TANK: FEE ENCLOSED:$ (/Jl SIZE OF WATER PIPING AND RISER: WATER HEATER: TYPE MANUFACTURER FEE SCHEDULE:$18 PER S1,000 OF THE ESTPAATED COST. ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS /5 f- S IN $1.00 OVER (.26 CENT EDUCATIONAL FEE INCLUDED AS PART i OF THE PERWr FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: Z TYPE: STATE: / G/ SIGNATURE OF APPLICANT• DATE: / / )9 1 i * APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOI , CT 06074(PHONE)860-644-2511 EXT.230 DEPARTMENT DECISION PERMIT NUMBER: APPLICATI BY: APPROVED. BLDG.PERMIT NUMBER: Z-4DA R LOCATION OF WORK: Z S � F��� L h APPLICANT: OWNER: TYPE OF STRUCTURE: l ❑NEW BUILDING NAME: Ui n[) NAME: f 1 L, c r }3 A DDITION PHONE NUMBER: ��c 4"?a 2 K�L/ PHONE NUMBER: �'nastvtG BUILDING ADDRESS: S2 Scat rt 4t IZ� ADDRESS: TYPE OF USE: oXFSIDENTIAL o COMMEPCIAL ELECTRICAL INFORMATION: FURTHER DESCRIPTION OF WORK: TYPE OF INSTALLATION: C c/7 q,L 01 i n beI Sclr�n SIZE OF SERVICE: O.-11 LL'LSo t�rc 1, bCti&,-�nr�, SIZE OF MAIN SERVICE: C_ I a,�'c 1 NUMBER OF METERS: Io r NUMBER OF PANELS: NUMBER OF LIGHT CIRCUITS: ESTIMATED COST:S 7 NUMBER OF SWITCHES: NUMBER OF LIGHT FIXTURES: FEE ENCLOSED:S NUMBER OF A/C CIRCUITS: FEE SCHEDULE:S18 PER S1,000 OF THE ESTIMATED COST. NUMBER OF POWER CIRCUITS: ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS S1.00 OVER (16 CENT EDUCATIONAL FEE INCLUDED AS NUMBER OF OUTLETS: PART OF THE PERMIT FEE) THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK, CONTRACTORS LICENSE NO.: O 203 073 TYPE: � / STATE: C T SIGNATURE OF APPLICANT: DATE: 4 i j �I NOTES: LEGEND 1. THIS MAP IS DEPENDENT ON THE MAP REFERENCED HEREON. 0 EXISTING IRON PIN 2. PARCEL ZONED RESIDENTIAL AA-30 OPEN SPACE SUBDIVISION. —300— EXISTING CONTOUR 3. UTILITY LOCATIONS AND INVERT ELEVATIONS TAKEN FROM AN x 287.3 EXISTING SPOT GRADE INSPECTION REPORT PROVIDED BY THE CONTRACTOR. 4. ALL ITEMS DEPICTED ON THIS PLAN HAVE BEEN VERIFIED IN THE FIELD AS TO LOCATION, ELEVATION, AND COMPLETENESS. OPEN SPACE 15 TO BE DEEDED TO THE TOWN OF SOUTH WINDS❑R CBp1 TF:258.73 254 INV:251.30(IN) 251.24(OUT) 256 252 INV:251.45(6") ` T I I 258 tN70'52'02'W O 2w N70'52'02'W �58 1 y54= o 250 \ \ GO 20' S.Y. 1 1 T t \ I I I rf� cq ry I ♦ 1 1 i A , t� \\`252 1 1 \ 1 1 11 1 1 II I A �VN� I ♦ 1 1 I 1 11 1 11254 l I ' I 40.35 1 1 `♦ 11 11 1 1256 I 1.9 ` 1 Ul 1� , 1 .ct«� �AS' 8n \ 1Il \ IN I,,v� d- $AN. AT t� �.O �NNK N = y' `♦ 1 1 Z tall. j` 0 1 f u �. ;� \ 1 ♦ ♦ UPLAND REM& I1 U7) P 1 I �^ 2. 1 \ 1 ♦ ��EA t II \ I r o 1 \ 42,808 sq. M \♦ 1 Z 0.9,1 AC. L254 20' S.Y. a U SMH#S BIT ORI WAY A Q i TF:260.83 ` ` INV':250.59 1 aj 1` \ ♦ \ 83.Sd` REFERENCE NOTE: 200.00, w 1 1 S70°52'02' ` BOUNDARY INFORMATION IS TAKEN FROM PLANS ENTITLED "POND ESTATES AT RED ROCK. S �„1 1 `\ \ 2558 256 `♦ RESUBDIVISION - LOT 6-9. DEMING HILL ESTATES - SECTION 7 SOUTH WINDSOR, CONNECTICUT. PREPARED FOR JMJ CONSTRUCTION BY DESIGN PROFESSIONALS, DATE 1-24-02 1 r .` �r �� `\ 250 \254 I THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-300b-1 THRU 20-30015-20 1 262 1 1 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES — "STANDARDS FOR SURVEYS AND MAPS IN THE 262 1 i STATE OF CONNECTICUT' AS ENDORSED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS. INC. 264 264 THIS SURVEY CONFORMS TO HORIZONTAL ACCURACY CLASS A-2 AND VERTICAL ACCURACY CLASS T-2. 20'STREET TREE EASEMENT IN FAVOR OF TO THE BEST OF MY KNOWLEDGE AND BELIEF, THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. THE TOWN OF SOUTH WINDSOR 13 10'CLAP EASEMENT JMJ CONSTRUCTION COMPANY 658 EWNGTON ROAD 12882 SOUTH WINDSOR. CT 06070 RICHARD P. MARTEL UC. No. TEL(860) 282-0628 rzEcolRP AS-MILT 860-291-8755 T.UNLESS oTNERWSE NOTED.EwsnNc UTILITY : DEPENDENT RESURVEY PREPARED FOR REVISIONS GRAPHIC SCALE ■ Paad meter At Reed Rack �®�If SHEET AVAILABLE AS SNa�ARE L EAS ONUTILITIES si n ���. P 1 SHOULD I`ICLO A80/1 ALL PRIOR 7 JG CONSTRUCTION. Q viff SHOULD BE nELO VERIFIED PRIOR TO CONSTRI1C110N. � � � � �+ • LZI{/ B ALL UTILITIES ARE S V srAK RI R THE FlEID &ro'ofessionals PEN SPACE SUBDIVISION —SECnON 7 BY A LICENSED LAND SURVEYOR PRIOR TO , � Inc.• �( �y D Rock � OF CONSTRUCTION. Lot No. 14 - b5 N� l oc Lane. AYN BY.' q/C .,w NR:9Q57I-r1 3. MS PLAN IS R/VALID UNLESS IT BEARS 1HE I L41• 1`>f 1S IMPRE59ON SEAL AND ORIpNAL SIGNATURE 1 inch = 40 feet civil engineers planners surveyors or TTfE PROrESS.=ENpNEER/SURVEYOR. NO. DATE DESCRIP17ON BY 1 165 south satellite rood, south wlndsor, Connecticut 06074 SOUTH WINDSOR. CONNECTICUT orm Br. RPU DA7E•5/74/DI MAY '' 6 South Windsor BUILDING DEPARTMCNIT - b t p Th! th 01 ! er S Re Pcc d t� 7e f I' i-. •n„ •.d d �'�h Q C yV/ RAY ?20 04 ENGINE R NlGOSDR DFpT RECEIVED MAY 2 8 2004 SITE COMPLIANCE CHECKLIST s 00 SOUTH WINDSOR PLANNING DEPT. TOWN of SOUTH WINDSOR, CONNECTICUT wy 6m d 25 REDROCK LANE LOT_#14 Reviewed By 6 (Engineering) CLARK REALTY, INC. Date Reviewed L$ZIDenied 4113 658 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By MIoc, (Planning) BP_#_29715_ Ph_#_(860)528-6 54 Date Reviewed 5jjzljy Epp d/Denied Date Submitted_:ML& 9 (, - 0- ***** FOR C of 0 *** ' As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include Approved Denied N/A 1 Approved building permit plan 2 Finish grading per approved building permit plan 3 Site work; i.e trees, shrubs, / dumpsters, required parking 4 Utility location; i� a. sanitary sewer/septic system t/ b. foundation drain c. electrical & telephone ✓ d. water e. ot-her 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Alk A. Lighting B Signage Freestanding Wall 0 C. Fee in lieu of Open Space /� f Sewer Permit No. Pav Exc # COMMENTS isonr' ` Status Electric # J'�- ?35— APPLICATION FOR BUILDING PERMIT Plumbing# 1 I ti'8 1 25 Red Rock Road Date: an S HVAC # IZ 1 SZ Sprinkler# 29 Z15 FINAL APPROVALS Estimated Cost $j3,7200 nc Building COMPLETE RED BOXED AREAS Permit Fee $ e .S'. 00 Occuan g. Engineering TYPE OR PRINT ONLY En Insp.cy Fee $ f Affidavit SIGN ON REVERSE SIDE Appr. for CO. Total Fee $ 'b 3 S. 60 TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant Location of Work Lot No.1 Applicant's Address Tel.# y� Town ig) Zip e Lc q!q Lic.# 36 6 Owner ,1 . Architect �� Owner's Address Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. „3 r 2nd FI. tsa- 3rd FI. Total New Area -1 Purpose of this permit�, ,,,�, � ,,, City Watq 2. Wello Septic System❑ Sewerg Ins: HO SP Cert. Area //t)- Basement IY37 Garage 736' Approved by 00. Date '76/01 Use Group Construction Type evlsed 8IO2 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS __ I Location of Job: AFFIDAVIT Additional Fee$ 4 2 0. State of Connecticut ss.South Windsor County of Iiartford Owner IkA of Agent r e building erecte Contractor urjer Permit No. 2 9 715 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BOCA value of$ 179,535. Signed Subscribed and sworn to before me this %-- day of A.D.20_6_6( Estimated Cost$ 151,900. Difference: $ 27,635. Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-29715-B 135,000 BO1 FOOTING 11/12/03 CJD A B02 FOUNDATION 11/24/03 WNB A COATING,DRAINS WITH CONTRACTOR CREW. PO4 GAS TEST 12/22/03 CJD D NO ACCESS TO BSMT E01 SERVICE 12/31/03 JFF A OK TO RELEASE TO NU BOS FIREPLACE/CHIMNEY 02/03/04 JFF A WITH CONTRACTOR ADD MECH TIES B03 FRAMING (ROUGH) 02/05/04 CJD D TIE DOWN CLIPS PER TRUSS SPECS, INSTALL LATERAL BRCNG TO SAME E03 ROUGH 02/23/04 JFF A LEFT APPROVAL NOTICE P03 ROUGH 02/24/04 JFF A WITH TIM IMPERIAL WATER VENTS DRAINS B04 INSULATION 03/23/04 PJP A W/ ROGER PO4 GAS TEST 04/05/04 CJD A **-12152-H 10,900 **-11489-P 3,000 **-18735-E 3,000 Total Est Value 151,900 Dwelling 2,912 146,328 00 Basement 1,437 21,555 00 Garage 736 11,040 00 Smoke Det 7 525 00 BOCA Value 179,535.36 Difference 27,635.36 3 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-29715-B 135,000 BO1 FOOTING 11/12/03 CJD A B02 FOUNDATION 11/24/03 WNB A COATING,DRAINS WITH CONTRACTOR CREW. PO4 GAS TEST 12/22/03 CJD D NO ACCESS TO BSMT E01 SERVICE 12/31/03 JFF A OK TO RELEASE TO NU BOS FIREPLACE/CHIMNEY 02/03/04 JFF A WITH CONTRACTOR ADD MECH TIES B03 FRAMING (ROUGH) 02/05/04 CJD D TIE DOWN CLIPS PER TRUSS SPECS, INSTALL LATERAL BRCNG TO SAME E03 ROUGH 02/23/04 JFF A LEFT APPROVAL NOTICE P03 ROUGH 02/24/04 JFF A WITH TIM IMPERIAL WATER VENTS DRAINS B04 INSULATION 03/23/04 PJP A W/ ROGER PO4 GAS TEST 04/05/04 CJD A B10 FINAL 05/25/04 CJD A W/ROGER B10 FINAL 05/28/04 CJD A CLOSEOUT **-12152-H 10,900 **-11489-P 3,000 **-18735-E 3,000 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 25 REDROCK LANE LOT_#14 Reviewed By 9-,Tb (En ineering) CLARK REALTY, INC. Date Reviewed D Denied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By lanning) BP_#_2971�5_ Ph_#_(860)528-6054 Date Reviewed ` prov /Denied Date Submitted 06/25/03 ***** FOR BUILDING PERM ***** In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval The minimum requirements shall include Approved Denied N/A 1 Name, address & phone number of owner/applicant 2 Name, address & phone number of plan preparer 3 Zoning Information - i e zone, open space, floodway, street address 4 Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc _ b. Easements of record c Lot description, bearings, building lines, distances, area, etc d. Contours, existing & proposed, 1 or 2 ft interval where appropriate e Building location with dimensions. Elevations of proposed finish floor, garage . / floor & centerline of road at driveway 1/ f Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street l� g. Tentative utility location (gas, water, electric, septic system, etc ) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements (P.E. & L.S ) i 5 Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS NOTES: LEGEN D 1. THIS MAP IS DEPENDENT ON THE MAP REFERENCED HEREON. 0 IRON PIN TO BE SET 2. THE BUILDING LOT SHALL BE LOAMED• SEEDED, AND MULCHED o MONUMENT TO BE SET WITH STRAW PRIOR TO ISSUANCE OF C.O. (IF THE SEASON DOES Soo- EXISTING CONTOUR NOT STRAWERMIT OR EROSIONG, THEN THE LOT CONTROL NETTING TOT BE PREVENTBILIZED WITH WINTER AND 300 PROPOSED CONTOUR SPRING EROSION.). PROPERLY INSTALLED EROSION AND SEDIMENT x 287.3 PROPOSED SPOT GRADE CONTROLS MUST BE IN PLACE TO CONTROL ANY EROSION AND SEDIMENTATION PROBLEMS. THE BUILDER/OWNER IS RESPONSIBLE 011111111 SILT FENCE FOR ALL STABILIZATION REQUIREMENTS. � DIRECTION OF SURFACE FLOW 3. ROOF LEADERS TO BE DISCHARGED ON SPLASH PADS. 4. ALL ROADWAY UTILITIES ARE TO BE INSTALLED IN COMPLIANCE x 287.3 EXISTING SPOT GRADE WITH THE APPROVED "DEMING HILL ESTATES' SUBDIVISION PLANS. _F PROP. 6" PVC FND. DRAIN (S=1.0% MIN.) 5. FINISHED GRADING AROUND THE HOUSE SHALL ALLOW A 3 INCH DROP IN GRADE AT A DISTANCE OF 6 FEET FROM THE FOUNDATION G PROP. GAS SERVICE AS SPECIFIED IN THE STATE OF CONNECTICUT BASIC BUILDING CODE. OPEN SPACE 6. PARCEL ZONED RESIDENTIAL AA-30 OPEN SPACE SUBDIVISION. S PROP. 6"SAN. LATERAL (S=2% MIN.) TO BE DEEDED TO THE 7. FOUNDATION DRAIN TO BE EQUIPPED WITH A BACK FLOW PREVENTOR w PROP. WATER SERVICE 15 TOWN OF SOUTH WINDS❑R (PROVIDE ACCESS TO SURFACE). CB/1 TF:258.73 INV:251.30(IN) 251.24(OUT) 256 254 252 INV.251.45(6-) 2% 1 N70.52*01*W a N70��2 Oi'w 58.5 % ANfiL rocs 1.5[T roes AND �.;' 225.00' 5•UPSLOPE EXCAVATE A c.c ;t;I; .•. �, ` ItFaI sTAeurr !� LPsaFE mw PEnn .. sT -- \ t 1 AND mr- \ 1 1 n t arArow. "• L12'NN. ' a \\ 0 S.Y. t ` ' T252 I OU � 4ry � 1, 1 It 11 t tl t tt `� I tt It tt t t254 t 1 ` t 11 I 3.ATTACH THE FABRIC TO a SACITI L 1NE a -7' 0 s.s$ AO.00 tt 1 't / 1 256 FILTER T URE FDEo4C AND EXTEND TRENCH AND CO 2.00' IIACT t 1 ; FADRIC n SOIL THE TRENCH THE EXCAVATED SC g - 00' COMPACTED ' I I �f h pp \ ' , \\ `\ I t Q ^� BACKnIl G' EV A N N R � a' t ` \ 1"�I Q .1 2 O i .#. . 14 t ► ' Z 0 A \ `- t ` �i,P1AND REv>Etin_ 0 2. t \ Ate► 1 � t 263. X zoo' $ >`� t t ♦ t W ; t 42,808 sq. M ♦ ` CONSTRUCTION OF SYNTHETIC FILTER BARRIER ITV.=250.16 � I I I �� g �s6 t ��se tt 0.98 AC. \ ♦ `� ` '254 ' ry\ 3200' 6� ` ♦ \ \\ ' t \ ♦ \ ` K N ANTI-TRACKING APRON Ifl t \ \ \ I 6'-r STONE ON FILTER € 1 \ `� ♦ T FAMC \ ' S.Y. \ \ PRO BIT. RIVE 63. TF 260.83 \♦ 83.5d' REFERENCE NOTE: INV:250.59 \ 200.00' (283.50' (LL) \ BOUNDARY AND TOPOGRAPHIC INFORMATION ARE TAKEN FROM PLANS ENTITLED �' S70'52 01 E 'POND ESTATES AT RED ROCK. RESUBDIVISION - LOT 6-9. DEMING HILL ESTATES - SECTION 7 SOUTH WINDSOR• CONNECTICUT. PREPARED FOR JMJ CONSTRUCTION BY DESIGN PROFESSIONALS. DATE 1-24-02 S \ 258 256 \ THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-300b-1 THRU 20-30015-20 I SILT FENCE�TMP� 260 fir.:'; fir• 254 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES - 'STANDARDS FOR SURVEYS AND MAPS IN THE _;C7 ; Gi STATE OF CONNECTICUr AS ENDORSED BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS. INC. 0 THIS SURVEY CONFORMS TO HORIZONTAL ACCURACY CLASS A-2 AND VERTICAL ACCURACY CLASS T-2. 'Y• ;= r - OWNER/APPLICANT TO TH WL DG S SUBSTANTIALLY CORRECT AS NOTED HEREON. ` w'�.� 20'STREET TREE FJ150AE1TT M FAVOR OF -•:Q JMJ CONSTRUCTION COMPANY WE TOVIN OF SOUTH TIINOSOR 13 o J 658 ELLINGTON ROAD Id CLtrP EASEMENT r,�� SOUTH WINDSOR, CT 06070 12882 S `a" :>` TEL.(860) 282-0628 RICHARD P. MARTEL LIC. No. 1.UNLESS OTHENMSE NOTED.EXISTING UTILITY REVISIONS 860-291-8755 DEPENDENT RESURVEY PREPARED FOR aff SHEET LOCATIONS AS SNDRRN ARE BASED ON � GRAPHIC SCALE � �eSi f1 Pond Etltd At Reid Rack ® F��T p r� AVAILABLE WORYATION.ALL"STING UIIUTIES 'j/y� A (�Yr 7m N1N�/ p 1 SHOULD BE FIELD VER6IED PRIOR TO CONSTRUCTION. »�� E�rE/V/I/'1) NWwN 11 2_ALL UTILITIES ARE TO BE STAKED N THE FIELD professionals, Inc. OPEN SPACE SUBDIVISIION -SECTION 7BY S RUCTION KIND$IIRVETOR PRIOR TO % of COMS1711/CT10M. I ORA IIIV BY!ACT ,.LIB A/O.:17Et311-1I I TNIS PLAN 6 NVAUD UNLESS IT BEARS THE 1 inch = 40 feet ! civil engineers plonners surveyors Lot No. 1E4 - Z§ Red Rock lAnt R+PREsvoN SEAL AND oRIaINAL SIGNATURE 165 south satellite rood• south Windsor• Connecticut 06074 SOUTH MANDSOR. CONNEC?1CVT OF THE PROFT:SsauL ENQNEER/SURVEYOR. N0. DAIE DESCRIP110N BY By., A71/ OATS 6 oJ o nw�m jUrj z a 2003 South Windsor BUILDING DEPARTMENT tt RECEIVED s OUTt- JR � ENGINEE,,,,�6 JER4 t 17 S— DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Applicatio ' hereby: ��3�' BUILDING DEPARTMENT CAAOVJZ� 1540 SULLIVAN AVENUE 3 644-2511 ext. 230 Permit# Date Bu ding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 140 AoeiL $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT M-W �- APPLICANT ADDRESS D OTC 1�-) APPLICANT PHONE# ��$ 0 W N S lrq OWNER OWNER ADDRESS 6 SS £[. i..l(=?pnJ , `E3 CIO p, OWNER PHONE 6HSt-O C = ESTIMATED COST$ ��DO r IS THIS A CONTRACT COST? Vies _No a �L FEE ENCLOSED$ y 5 O U c rN TYPE OF JOB: �sOR C0N Z New Installation —Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION?4 YES ❑NO RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY 4� ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY s O EN C C ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD Q��,J 5 5 •� +' ,� `- SIZE OF SERVICE ja� !, SIZE OF MAIN CONDUCTORS J qU A L NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS 'aoo Rm P NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES NO NUMBER OF LIGHT CIRCUITS 6 NUMBER OF POWER CIRCUITS S NUMBER OF SWITCHES a�� NUMBER OF OUTLETS So NUMBER OF LIGHT FIXTURES aS NUMBER OF HEAT CIRCUITS r NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK ew H6-k 5 C- THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE DATE SIGNATURE OF APPLICANT cam' o� Q O APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A ©(ESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES W-N'O ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE �. �.� NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS�_ SIZE NO.OF STACKS_� SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDO V OYES ❑NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWE�OR SEPTIC TANK SIZE OF WATER MAIN \ SIZE OF WATER PIPING&RISER QX WATER HEATER: TYPE ��, MANUFACTURER i") � p c �. c a ,(y DESCRIPTION OF WORK IVE UNDERSIGNED HER Y APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRI13ED AND is T7— COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 2-C� CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT'� ,V �n �,s o. DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMTT# Application reby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT fAPPRO 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date B d ng Inspector Application must be printed or typed FEE SCHEDULE p(S Location of Job: $0-$1,000=$15.00 [TTe-nWa—nt eet No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Designation Apt.No. APPLICANT APPLICANT ADDRESS c, S C,7\ APPLICANT PHONE# OWNER n �y 4. Ni3 Fq \ OWNER ADDRESS �a - ti 1 ) Or. OWNER PHONE O C ESTIMATED COST$ OUc� IS THIS A CONTRACT COST? ✓ Yes _No �G FEE ENCLOSED$ TYPE OF JOB: SOR-C� VNew Installation _Alteration/Addition/Repair Revised 4/01H2002 Shirley Wilhelm -CRS Approval Confirmation: Request No. 310340 Page 1 From: <clpsvc@nu.com> To: <WILHEL@SOUTHWINDSOR.ORG> Date: 12/31/03 2:06PM Subject: CRS Approval Confirmation: Request No. 310340 Your approval of the following CRS Request has been successfully processed. CRS Work Request M 310340 House No: Lot No: 14 Street Name: RED ROCK LN Town Name: SOUTH WINDSOR, CT Inspector: CHRISTOPHER DOUGAN Approval Date: Dec 31, 2003 DEPARTMENT DECISION APPLICATION FOR 1 VAC PERMIT PERMIT# TOWN OF SOUTH WINDSOR Applic is ere BUILDING DEPARTMENT APPR 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 )9-7 ; ate v. Application must be printed or typed FEE SCHEDULE Location of Job: C1 Z",O r/e / $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRE S / i 7 APPLICANT PHONE# 77 a OWN S OWNER > q� OWNER ADDRESS 5 /,f _ OWNER PHONE O C ESTIMATED COST$ IS THIS A CONTRACT COST? —Yes _No FEE ENCLOSED$ f TYPE OF JOB: SOR.COS vNSew Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: EATING ❑RESIDENTIAL A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC )R WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE e�) F INSIDE 7°F DIFFERENCE OF TOTAL HEAT LOSS(BTUH)6"°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) e,/ Id o GROSS HEATING CAPACITY(INPUT—BTUH)/j2g aa0 NET RATING(OUTPUT BTUH) fo ifrYJ TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE gg OF INSIDE_��OF DIFFERENCE 1,e' OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)EQUIPMENT DESCRIBE ALL COOLING ENT(INCLUDING MAKE&MODEL NO.) ea z Pik TONNAGE ,-� COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE gSTATE SIGNATURE OF APPLICA1lT DATE RIGHT-J SHORT FORM Entire House R & E Heating & Cooling Inc. Job: 259-014 23 Rel Rock Lane 3-19-04 310 Nutmeg Rd.South,South Windsor,CT 06074 Phone:860-282-7782 Fax:860-282-7701 Project • • For: Clark Realty,lnc 658 Ellington RD, South Windsor, CT 06074 , - • • • Htg clg Infiltration Outside db (°F) 6 88 Method Simplified Inside db (°F) 70 70 Construction quality Average 1 Design TD (°F) 64 18 Fireplaces Daily range - M Inside humidity(%) - 50 Moisture difference (gr/lb) - 38 HEATING EQUIPMENT COOLING EQUIPMENT Make Heil Make Heiil Trade HEIL Trade Heil H9MPD100 HAC060 EPD060 Efficiency 90.0 AFUE Efficiency 10.0 EER Heating input 100000 Btuh Sensible cooling 42000 Btuh Heating output 90000 Btuh Latent cooling 18000 Btuh Total cooling60000 Btuh Heating temperature rise 41 °F Actual heating fan 2000 cfm Actual cooling fan 2000 cfm Heating air flow factor 0.033 cfm/Btuh Cooling air flow factor 0.051 cfm/Btuh Space thermostat Load sensible heat ratio 80 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ff2) (Btuh) (Btuh) (cfm) (cfm) zone 1 n p 1224 30145 24545 994 1262 zone 2 n p 399 13183 9613 435 494 zone 3 n p 608 7387 4344 244 223 zone 4 n p 648 9921 6037 327 310 Entire House d 2879 606360 388920 2000 2000 Ventilation air 36170 Equip. @ 0.93 RSM g878 Latent cooling TOTALS 2879 60636 46048 2000 2000 Printout certified by ACCA to meet all requirements of Manual J 7th Ed wrig[1tsoft Right-Suite Residentiail"5.028 RSR27412 2004-Mar-19 16:52:45 Page 1 A&I-A C\My Documents\Wrightsoft HVAC\259-014 23 Red Rock Lane rsr ' RIGHT-1 LOAD AND EQUIPMENT SUMMARY . Entire House R & E Heating & Cooling Inc. Job:269-014 23 Rel Rock Lane 3-19-04 310 Nutmeg Rd.South,South Windsor,CT 06074 Phone:860-282-7782 Fax:860-282-7701 Project • • For: Clark Realty,lnc 658 Ellington RD, South Windsor, CT 06074 Notes: 259-014 23 Red Rock Lane Design Information Weather: Hartford, Brainard Field, CT, US Winter Design Conditions Summer Design Conditions Outside db 6 OF Outside db 88 OF Inside db 70 OF Inside db 70 OF Design TD 64 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 38 gr/lb '.eating Summary Sensible Cooling Equipment Load Sizing Building heat loss 60636 Btuh Structure 38892 Btuh Ventilation air 0 cfm Ventilat4_ : 0 Btul1 Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 60636 Btuh '.;se mfg. data n Rate/swing multiplier 0.93 Infiltration Total Sens. equip. load 36170 Btuh Method Simplified Latent Cooling Equipment Load �ltct�r Construction quality Average Fireplaces 1 Internal gains 5060 Btuh Ventilation 0 Btuh Heatingg cooling Infiltration 4818 Btuh Area(ft2) 2879 2879 Total latent equip. load 9878 Btuh \/nlurne(ft3) 28079 28079 " =4 -i iges/hour 0.9 0.4 Total equipment load 46048 Btuh Equiv.AVF (cfm) 422 188 Heating Equipment Summary Cooling Equipment Summary Make Heil Make Heiil Trade HEIL Trade Heil H9MPD100 HAC060 EPDO60 Efficiency 90.0 AFUE Efficiency 10.0 EER :tting Input 100000 Btuh Sensible cooling 42000 Btuh ::&GaiZg output 90000 Btuh Latent cooling 18000 Btuh Heating temp rise 41 OF Total coolin.o 60000 B`-_ Actual heating fan 2000 cfm Actual couiiriy la'. 2000 Cirri Heating air flow factor 0.033 cfm/Btuh Cooling air flow factor 0.051 cfm/Btur1 Space thermostat Load sensible heat ratio 80 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. t wng"tsoft Right-Suite Residential^'5.0.28 RSR27412 2004-Mar-1916:52:45 AC� C:Wy Documents\Wrightsoft HVAC'259-014 23 Red Rock L.... Page 1