HomeMy WebLinkAbout25 CASE HILL CIR APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT l H oo s 13 AP RO D 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspeao7r Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00Fi-- $15.00 l= l► 1 C7 Over$1,000= Street Lot No. per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT A pt tJ ?b w-.P-CS APPLICANT ADDRESS l V\Y, 7- C)(0-0 APPLICANT'S PHONE# OWNER W n•.i)p• 5 Pi j\-2f-- OWN SFq< OWNER ADDRESS OWNER PHONE o-P'�U " 'FS 3 3 ESTIMATED COST$ o c,.o C � V IS THIS A CONTRACT ST? Yes -'No FEE ENCLOSED$ �Lj �4,� TYPE OF JOB: SOR•C0 New Installation Alteration/Addition/Repair G Revised 03/05/10 APPLICATION FOR HVAC PERNIIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0-HEATING ❑ RESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. 0- HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) O }� + L-.-) -� GROSS HEATING CAPACITY(INPUT-BTUH) (P o,, NET RATING(OUTPUT BTUH) 7 o o TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY Zr GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE 1 SIGNATURE OF APPLICANT DATE / ^eference is made to map entitled "Case HILL" Zone A-20 Plot Plan , ?roperty of R. S K. Contractors , Pleasant Valley Road, South Windsor . Conn ; 8-14-82 Rev 10-14-82 , 1-17-83 , 4-7-83 , 7-13-83 , Lucek Engin- eering Assoc. Inc " O r�aanm g CONNED l� ,y���`avE4 M.lGccG✓ , Z,P N Z4°- O NlS D SX o '+ no.ez9i 1 _ 16°0(6=4,.0�� NAL ENG� w \ \ �FZ= SO.00 + L= 4.41 �M IN,� IZ(o 2� Ln V1 ` 0_ `1 of 13 �3,24,l27 S.3Z. / .9 inin i in r"cy j v fFG � zp Z - M. I5 i 9- Mtn 7— IZO _ c /r.P 93 90, 4 ' N Q�_3Z, MS. / Applicant R.S K. Contractors Inc 1750 Ellington Road South Windsor, Ct. 203-644-8761 - Zone A-20 Property of R. S.K. Contractors Inc. 15 Case Hill Circle South Windsor , Ct. LUCEK. ENGINEERING. ASSOC. INC. NO. REVISIONS DATE j SCALE 1"=40 ' DATE CONSULTING ENGINEERS ENGINEERS 490 SUCKLAND ROAD DRAWN M10 CHECKED ewl SOUTH WINMR. CONN. 203,&AA-iAi6 FROJECT82.-19 SHEET 1 6++ I HEREBY CERTIFY THAT THIS MAP AND SURVEY WERE PREPARED IK IICCORDA�! EE901NCE HE STANDARDS OF A CLASS _�_ SURVEY AS DEFINED IN THE EXISTING "CO F FOR STANDARDS OF ACCURACY OF SURVEYS AND MAPS ADOPTED BY U ASSOCIATION OF LAND SURVEYORS INC. FOR BUILDING PURPOSES ONL st . A P P OVED TOWN O± "-'UTH V.11NDSOR ENGI ^RI G D :PA. ENT DATE: SIG.: TICA 15BSeriesII Gas-Fired Water Boilers TING The Utica Heating 15B Series II Boiler has been redesigned with new control features making it an ideal 2012 DOE Compliant home heating solution with fuel efficiencies of 82%AFUE. SYSTEM FEATURES ■ New 2012 DOE Compliant Control- An integrated Hi-Limit Control, Vent Damper Control and Intermittent Spark Control housed under a protective cover. Utilizes thermal purge logic to maximize fuel savings. • ■ Quality Heat Exchanger Design - The 15B Series II features a robust cast iron heat exchanger for longevity. The sections are connected with cast iron push nipples, which expand and contract at the same rate as the sections ensuring a water tight seal. The 15B Series II is available in a full range of sizes from 45 MBH up to 295 MBH Input capacity. S\C ■ Efficiency — The 15B Series II provides "NG an annual fuel utilization efficiency of 82% s as certified by the US Department of Energy testing standards. _ i ■ Easy Installation and Maintenance - A compact design, low profile draft hood and top supply piping connections allow for easier 1. r installation. The pilot is mounted to the front of the burner base. • 15B SERIESIIGAS-FIRED HOT-WATER BOILERS Net AHRI Pump Size Input Heating Natural '� Dimensions(Inches) Number AFUE Boiler Rating Supply Number Mbh Capacity Water Gas &Return of Elec. Ign. (1) MBH(1) Mbh(2) Inlet A B C D E F Tappings Burners &Damper UH15BO45FE 45 37 32 1/2" 111/4 55/8 4 271/8 20//16 415/16 11/4" 1 82.0% • UH15BO70FE 70 57 50 1/2" 151/8 7 5 281/6 2015/16 415/16 11/4" 2 82.0% UH15BO96FE 96 79 69 1/2" 151/8 1 7 5 281/8 2015/16 4t5/16 1 11/4" 2 82.0% UH15B120FE 120 98 85 1/2" 19 91/2 6 291/8 217/16 57/16 1'A" 3 82.0% UH15B145FE 145 119 103 1/2" 19 91/2 6 291/6 217/16 5//16 11/4" 3 82.0% UH15B175FE 170 140 122 1/2' 227/8 113/16 7 301/8 2115/16 515/16 11/4" 4 82.0% UH15B195FE 195 160 139 1/2" 227/8 113/16 7 301/6 2115/16 515/16 11/4" 4 82.0% UH15B245FE 245 201 174 3/4" 263/4 136/16 8 311/8 j 227/16 615/16 1'/4" 5 82.0% UH15B295FE 295 242 210 3/4" 305/8 155/16 9 321/8 1 2215/16 1 8t5/16 1'A" 6 82.0% Mfg. Number Boiler Number Description 550001270 UH15BO45FE Propane to Natural Gas conversion kit — All boilers are design certified for installation on 550001271 UH15BO70FE Propane to Natural Gas conversion kit noncombustible floor. 550001272 UH158096FE Propane to Natural Gas conversion kit — Recommended chimney height 20 feet. In special 550001273 UH15B120FE Propane to Natural Gas conversion kit cases where conditions permit, chimney height may 550001274 UH15B145FE Propane to Natural Gas conversion kit be reduced to 10 feet. Refer to the latest revision of NFGC part 11. 550001275 UH156175FE Propane to Natural Gas conversion kit — Electric service to be 120 Volts, 15 Amps, 60 Hz. 550001276 UH15B195FE Propane to Natural Gas conversion kit — The MEA number for the this boiler is 19-79-E. 550001277 UH15B245FE Propane to Natural Gas conversion kit 550001278 UH15B295FE Propane to Natural Gas conversion kit (1) Input rating for sea level to 2,000 ft. (610m) above 550001279 UH15B045FE Natural Gas to Propane conversion kit sea level. United States, over 2000 ft (610m) above sea level. Reduce input rate 4%for every 1,000 ft 550001280 UH15BO70FE Natural Gas to Propane conversion kit (304m) above sea level. 550001281 UH15BO96FE Natural Gas to Propane conversion kit (2) Net AHRI Water Ratings shown based on piping 550001282 UH15B120FE Natural Gas to Propane conversion kit and pickup allowance of 1.15. Consult manufacturer 550001283 UH15B145FE Natural Gas to Propane conversion kit before selecting boiler for installations having unusual 550001284 UH15B175FE Natural Gas to Propane conversion kit piping and pickup requirements, such as intermittent 550001285 UH15B195FE Natural Gas to Propane conversion kit system operation, extensive piping systems, etc. • 550001286 UH15B245FE Natural Gas to Propane conversion kit For forced hot water systems where boiler and allpiping within area to be heated, boiler may be 550001287 UH15B295FE Natural Gas to Propane conversion kit selected on basis of its heating capacity. STANDARD EQUIPMENT: ■ Boiler Jacket ■ A.S.M.E. Relief Valve 255/16' B•• • Cast-Iron Boiler Battery ■ Drain Valve 1 1/4"SUPPLY\ „c T. ■ High Limit Control ■ Spill Switch �39n6' —r ■ Vent Damper Relay ■ Rollout Switch f— ■ Circulator ■ Automatic Vent Damper ■ Main Gas Burners OPTIONAL: ■ Combination Gas Control includes: P P Propane option available 31/7 11/4"RETURN •Automatic Gas Valve • Gas Pressure Regulator �� 1 1/4/4 • Intermittent Pilot • Safety Shut Off .49/16 • Pilot Flow Adjustment 1 , ` . r > s 7/a • Pilot Filter — Ratings and specifications subject to change without notice. us H SA. � r'NIG 2201 Dwyer Ave., Utica, NY 13501 Phone: (315)797-1310 USA Contractor Assistance: 800-325-5479 Fax: (866)432-7329 e c r PN 240006741 Rev.8/12 CALCULATION PROPOSAL FOR: TANYA SPILLER 25 CASE HILL CIR SOUTH WINDSOR,CT 06074 10/30/2014 Prepared 10/302014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 1 of 11 Room Specifications: KITCHEN Room Length(Ft) 13 Sq.Ft windows facing NE&NW: — Watts Incandescent Light: 200 Room Width(Ft.) 20 Sq.Ft windows facing South: 24 Watts Flourescent Light: — Room Height(Ft.) 8 Sq.Ft windows facing SE&SW: — Duct Length from A/H to room: 15 Exposed Wall Length(Ft): 33 Number of Exterior Doors: 1 Number of Large Electric Motors: — Wall against unconditioned room(Ft):— Sq.Ft Exterior Doors: 42 Average Electric Motor Horsepower. — Sq.Ft windows facing North: — Number of People in Room: 2 BTUH Appliance Sensible Heat: 1200 Sq.Ft windows facing E&W: 12 BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenheit) Summer. Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space: 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Unconditioned Basement Exposed Wags:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Duct Insulation Factor: 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter): 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows .900 Space Shading Factor: .4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH): 486 Appliance/Elec Motor Latent Heat Gain(BTUH): 400 Ceiling or Roof Heat Gain(BTUH) 829 Appliance/Elec Motor Sensible Heat Gain(BTUH):2382 Floor Heat Gain(BTUH) -259 Ventilation Latent Heat Gain(BTUH) 903 Glass Heat Gain(BTUH): 679 Ventilation Sensible Gain(BTUH) 1673 Exterior Door&North Window Heat Gain(BTUH) 406 Summer Total Latent Heat Gain: 1303 Solar Heat Gain(BTUH): 1032 Summer Total Sensible Heat Gain(BTUH) 7296 Total Transmission Heat Gain(BTUH) 3173 TOTAL SUMMER COOLING LOAD(BTUH): 8599 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 5821 Latent Ventilation Heat Losses(BTUH) 677 Sensible Ventilation Heat Losses(BTUH) 5239 Hydronic Heat(Linear Ft.) 20 TOTAL WINTER HEATING LOAD(BTUH) 11737 Calculated Totals for Entire Structure Size of Structure(Sq.Ft.): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear Ft.): 84.33 Total Cooling Requirement(Tons): 3.64 Total latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,dud Installation,and structure design may vary on each estimate and should be taken into account Correct system sizing Is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Ouidc Loads Pro-Version 1.01-SN:OP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 2 of 11 Room Specifications:FAMILY ROOM Room Length(Ft.) 19 Sq.Ft windows facing NE&NW: — Watts Incandescent Light: 200 Room Width(Ft.) 12 Sq.Ft windows facing South: — Watts Flourescent Light: — Room Height(Ft) 8 Sq.Ft windows facing SE&SW: — Dud Length from A/H to room: 15 Exposed Wall Length(Ft.) 31 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(Ft):— Sq.Ft.Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: 20 Number of People in Room: 2 BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W: 20 BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenheit) Summer: Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground. 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement: 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Unconditioned Basement Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground): .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Dud Insulation Factor 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows .900 Space Shading Factor: •4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft: 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 456 Appliance/Elec Motor Latent Heat Gain(BTUH) 400 Ceiling or Roof Heat Gain(BTUH) 727 Appliance/Elec Motor Sensible Heat Gain(BTUH):1182 Floor Heat Gain(BTUH) -227 Ventilation Latent Heat Gain(BTUH) 204 Glass Heat Gain(BTUH) 377 Ventilation Sensible Gain(BTUH) 378 Exterior Door&North Window Heat Gain(BTUH) 193 Summer Total Latent Heat Gain: 604 Solar Heat Gain(BTUH): 1720 Summer Total Sensible Heat Gain(BTUH) 4861 Total Transmission Heat Gain(BTUH) 3247 TOTAL SUMMER COOLING LOAD(BTUH) 5465 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 3995 Latent Ventilation Heat Losses(BTUH) 153 Sensible Ventilation Heat Losses(BTUH) 1184 Hydronic Heat(Unear Ft.) 9 TOTAL WINTER HEATING LOAD(BTUH) 5332 Calculated Totals for Entire Structure Size of Structure(Sq.Ft): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear Ft): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractors experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken Into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 f CALCULATION Heat Load Detail Report for TANYA SPILLER Room 3 of 11 Room Specifications: DINING ROOM Room Length(Ft.) 12 Sq.Ft windows facing NE&NW: — Watts Incandescent Light: 200 Room Width(FL) 11 Sq.Ft windows facing South: 8 Watts Flourescent Light: — Room Height(Ft.) 8 Sq.Ft windows facing SE&SW. — Dud Length from A/H to room: 15 Exposed Wall Length(FL) 15 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(FL):— Sq.FL Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: 12 Number of People in Room: 2 BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W. 12 BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenhe(t) Summer. Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement: 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Unconditioned Basement Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground): .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Dud Insulation Factor: 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows .900 Space Shading Factor: .4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft 600 Calculated Room Results-Summer Heat Gains W211 Heat Gain(BTUH) 221 Appliance/Elec Motor Latent Heat Gain(BTUH): 400 Ceiling or Roof Heat Gain(BTUH) 421 Appliance/Elec Motor Sensible Heat Gain(BTUH):1182 Floor Heat Gain(BTUH) -131 Ventilation Latent Heat Gain(BTUH) 118 Glass Heat Gain(BTUH) 377 Ventilation Sensible Gain(BTUH) 219 Exterior Door&North Window Heat Gain(BTUH) 116 Summer Total Latent Heat Gain: 518 Solar Heat Gain(BTUH) 1032 Summer Total Sensible Heat Gain(BTUH) 3482 Total Transmission Heat Gain(BTUH) 2036 TOTAL SUMMER COOLING LOAD(BTUH) 4000 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH): 2720 Latent Ventilation Heat Losses(BTUH) 89 Sensible Ventilation Heat Losses(BTUH) 686 Hydronic Heat(Linear Ft.) 6 TOTAL WINTER HEATING LOAD(BTUH) 3494 Calculated Totals for Entire Structure Size of Structure(Sq.Ft.): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear Ft.): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many toots required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 1 013 020 1 4 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 I CALCULATION Heat Load Detail Report for TANYA SPILLER Room 4 of 11 Room Specifications: LIVING ROOM Room Length(Ft.) 13 Sq.Ft windows facing NE&NW: — Watts Incandescent Light: 200 Room Width(Ft.) 21 Sq.Ft windows facing South: 18 Watts Flourescent Light: — Room Height(Ft.) 8 Sq.Ft windows facing SE&SW: — Dud Length from A/H to room: 15 Exposed Wall Length(Ft.) 34 Number of Exterior Doors: 1 Number of Large Electric Motors: — Wall against unconditioned room(FL):— Sq.Ft.Exterior Doors: 21 Average Electric Motor Horsepower. — Sq.Ft windows facing North: — Number of People in Room: 2 BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W: 18 BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenheit) Summer. Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 550 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Unconditioned Basement Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person), 200 Exposed Walls(Below Ground): •5 Duct Insulation Factor: 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors: 500 00 Air Change Factor(Air change per hour) 5 Windows Space Shading Factor: •4 Air Handler Design Cooling(CFM per ton): 400 Hydronic Heat(BTUH per linear ft: 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 500 Appliance/Elec Motor Latent Heat Gain(BTUH) 400 Ceiling or Roof Heat Gain(BTUH) 871 AppliancelElec Motor Sensible Heat Gain(BTUH) 1182 14 Floor Heat Gain(BTUH) -272 Ventilation Latent Heat Gain(BTUH) Glass Heat Gain(BTUH) 679 Ventilation Sensible Gain(BTUH), 1695 Exterior Door&North Window Heat Gain(BTUH) 203 Summer Total Latent Heat Gain: 1314 Solar Heat Gain(BTUH): 1548 Summer Total Sensible Heat Gain(BTUH) 6470 Total Transmission Heat Gain(BTUH) 3529 TOTAL SUMMER COOLING LOAD(BTUH) 7785 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 5262 Latent Ventilation Heat Losses(BTUH) 6886 Sensible Ventilation Heat Losses(BTUH) 5306 Hydronic Heat(Linear Ft.) TOTAL WINTER HEATING LOAD(BTUH) 11254 Calculated Totals for Entire Structure Size of Structure(Sq.Ft): 1643 Total Sensible Heat Gain(BTUH): 3652 4 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 3652 Total Hydronic Heat(Linear FL): 84.33 Total Cooling Requirement(Tons): .654 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors In sizing and installing a complete system.The weather,customer usage,dud installation,and structure design may vary on each estimate and should be taken Into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 5 of 11 Room Specifications:HALUSTAIRS Room Length(Ft.) 7 Sq.Ft windows facing NE&NW. — Watts Incandescent Light. 100 Room Width(Ft.) 13 Sq.Ft windows facing South: — Watts Flourescent Light — Room Height(Ft.) 12 Sq.Ft windows facing SE&SW: — Duct Length from A/H to room: 15 Exposed Wall Length(FL) 7 Number of Exterior Doors: 1 Number of Large Electric Motors: — Wall against unconditioned room(FL):— Sq.Ft.Exterior Doors: 21 Average Electric Motor Horsepower. — Sq.Ft windows facing North: — Number of People in Room: — BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W: 8 STUN Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenhelt) Summer. winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space: 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(AtticlCrawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) 075 Duct Insulation Factor: 1 Partitions . Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 .055 Duct Temperature Difference(Winter) 45 Floor(Above basement) 83 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) 001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows •900 Space Shading Factor: •4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft: 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 155 Appliance/Elec Motor Latent Heat Gain(BTUH) 0 Ceiling or Roof Heat Gain(BTUH) 290 Appliance/Elec Motor Sensible Heat Gain(BTUH):92 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) Glass Heat Gain(BTUH) 151 Ventilation Sensible Gain(BTUH) 1468 Exterior Door&North Window Heat Gain(BTUH) 203 Summer Total Latent Heat Gain: 792 Solar Heat Gain(BTUH) 688 Summer Total Sensible Heat Gain(BTUH) 3343 Total Transmission Heat Gain(BTUH) 1487 TOTAL SUMMER COOLING LOAD(BTUH) 4135 Calculated Room Results-Winter Heat Losses 594 Transmission Heat Losses(BTUH) 1831 Latent Ventilation Heat Losses(BTUH) 12 Sensible Ventilation Heat Losses(BTUH) 4597 Hydronic Heat(Linear Ft.) TOTAL WINTER HEATING LOAD(BTUH) 7022 Calculated Totals for Entire Structure Size of Structure(Sq.Ft.): 1643 Total Sensible Heat Gain(BTUH): 3652 4 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 3652 3.64 Total Hydronic Heat(Linear Ft.): 84.33 Total Cooling Requirement(Tons): 1454 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractors experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 6 of 11 Room Specifications:BATH Room Length(Ft.) 8 Sq.Ft windows facing NE&NW. — Watts Incandescent Light: 100 Room Width(Ft.) 6 Sq.Ft windows facing South: 3 Watts Flourescent Light: — Room Height(Ft) 8 Sq.Ft windows facing SE&SW. — Duct Length from A/H to room: 15 Exposed Wall Length(Ft) 6 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(Ft):— Sq.Ft Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: — Number of People in Room: 1 BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W. — BTUH Appliance Latent Heat: — IndoodOutdoor Design Temperatures(degrees Farenheit) Summer: Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(AttictCrawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement' 60 Unconditioned Basement: 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Dud Insulation Factor: 1 Partitions .075 Dud Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter): 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows .900 Space Shading Factor: .4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear It 6W Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 88 Appliance/Elec Motor Latent Heat Gain(STUN) 200 Ceiling or Roof Heat Gain(BTUH) 153 Appliance/Elec Motor Sensible Heat Gain(BTUH):591 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) 43 Glass Heat Gain(BTUH) 57 Ventilation Sensible Gain(STUN) 80 Exterior Door&North Window Heat Gain(BTUH) 0 Summer Total Latent Heat Gain: 243 Solar Heat Gain(BTUH) 0 Summer Total Sensible Heat Gain(BTUH) 994 Total Transmission Heat Gain(BTUH) 298 TOTAL SUMMER COOLING LOAD(BTUH) 123T Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 581 Latent Ventilation Heat Losses(BTUH) 32 Sensible Ventilation Heat Losses(BTUH) 249 Hydronic Heat(Linear Ft.) 1 TOTAL WINTER HEATING LOAD(BTUH) 863 Calculated Totals for Entire Structure Size of Structure(Sq.Ft): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear Ft.): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 7 of 11 Room Specifications:BEDROOM#1 Room Length(Ft.) 10 Sq.R windows facing NE&NW: — Watts Incandescent Light: 100 Room Width(Ft.) 11 Sq.Ft windows facing South: — Watts Flourescent Light: — Room Height(Ft.) 8 Sq.Ft windows facing SE&SW: — Duct Length from A/H to room: 15 Exposed Wall Length(Ft.) 10 Number of Exterior Doors: — Number of Large Electric Motors: — WaII against unconditioned room(FL):— Sq.Ft.Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: 14 Number of People in Room: 1 BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W: — BTUH Appliance Latent Heat: — IndoorlOutdoor Design Temperatures(degrees Farenhelt) Summer: Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground: 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(AtticlCrawl Space) 130 Above Ceiling(AtticlCrawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground): .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground): .5 Dud Insulation Factor: 1 Partitions: .075 Dud Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows .900 Space Shading Factor: •4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft: 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 147 Appliance/Elec Motor Latent Heat Gain(BTUH): 200 Ceiling or Roof Heat Gain(BTUH) 351 Appliance/Elec Motor Sensible Heat Gain(BTUH):591 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) 98 Glass Heat Gain(BTUH) 0 Ventilation Sensible Gain(BTUH) 183 Exterior Door&North Window Heat Gain(BTUH) 135 Summer Total Latent Heat Gain: 298 Solar Heat Gain(BTUH): 0 Summer Total Sensible Heat Gain(BTUH) 1437 Total Transmission Heat Gain(BTUH) 633 TOTAL SUMMER COOLING LOAD(BTUH) 1735 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 1114 Latent Ventilation Heat Losses(BTUH) 74 Sensible Ventilation Heat Losses(BTUH) 571 Hydronic Heat(Linear Ft.): 3 TOTAL WINTER HEATING LOAD(BTUH) 1760 Calculated Totals for Entire Structure Size of Structure(Sq.FL): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear FL): 84.33 Total Cooling Requirement(Tons): 3. 64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken Into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 8 of 11 Room Specifications: BEDROOM#2 Room Length(FL) 13 Sq.Ft windows facing NE&NW: — Watts Incandescent Light 100 Room Width(Ft): 13 Sq.Ft windows facing South: — Watts Flourescent Light — Room Height(Ft.) 8 Sq.Ft windows facing SE&SW: — Duct Length from A/H to room: 15 Exposed Wall Length(Ft) 13 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(Ft):— Sq.Ft Exterior Doors: — Average Electric Motor Horsepower: — Sq.Ft windows facing North: 16 Number of People in Room: 1 BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W: — BTUH Appliance Latent Heat: — IndoorlOutdoor Design Temperatures(degrees Farenheit) Summer. Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement: 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Dud Insulation Factor: 1 Partitions .075 Dud Temperature Difference(Summer) 20 Roof/Ceiling .055 Dud Temperature Difference(inter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) •001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows •900 Space Shading Factor: .4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft: 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH): 191 AppliancefElec Motor latent Heat Gain(BTUH) 200 Ceiling or Roof Heat Gain(BTUH) 539 Appliance/Elec Motor Sensible Heat Gain(BTUH):591 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) 151 Glass Heat Gain(BTUH) 0 Ventilation Sensible Gain(BTUH) 280 Exterior Door&North Window Heat Gain(BTUH) 155 Summer Total Latent Heat Gain: 351 Solar Heat Gain(BTUH) 0 Summer Total Sensible Heat Gain(BTUH) 1790 Total Transmission Heat Gain(BTUH) 885 TOTAL SUMMER COOLING LOAD(BTUH) 2141 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 1408 Latent Ventilation Heat Losses(BTUH) 113 Sensible Ventilation Heat Losses(BTUH) 878 Hydronic Heat(Linear Ft) 4 TOTAL WINTER HEATING LOAD(BTUH) 2400 Calculated Totals for Entire Structure Size of Structure(Sq.Ft): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear FL): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 9 of 11 Room Specifications:BEDROOM#3 Room Length(Ft.) 17 Sq.Ft windows facing NE&NW: — Watts Incandescent Light 100 Room Width(Ft) 13 Sq.Ft windows facing South: — Watts Flourescent Light: — Room Height(Ft) 8 Sq.Ft windows facing SE&SW: — Dud Length from A/H to room: 15 Exposed Wall Length(Ft.) 30 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(Ft):— Sq.Ft Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: 12 Number of People in Room: 2 BTUH Appliance Sensible Heat — Sq.Ft windows facing E&W: 12 BTUH Appliance Latent Heat — IndoorlOutdoor Design Temperatures(degrees Farenheit) Summer: Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground. 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(AttictCrawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement: 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Duct Insulation Factor: 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter): 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab): .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors: •500 Air Change Factor(Air change per hour) .5 Windows •900 Space Shading Factor: .4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft: 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 442 Appliance/Elec Motor Latent Heat Gain(BTUH): 400 Ceiling or Roof Heat Gain(BTUH) 705 Appliance/Elec Motor Sensible Heat Gain(BTUH):841 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) 198 Glass Heat Gain(BTUH) 226 Ventilation Sensible Gain(BTUH) 367 Exterior Door&North Window Heat Gain(BTUH) 116 Summer Total Latent Heat Gain: 598 Solar Heat Gain(BTUH) 1032 Summer Total Sensible Heat Gain(BTUH) 3776 Total Transmission Heat Gain(BTUH) 2521 TOTAL SUMMER COOLING LOAD(BTUH) 4374 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 2889 Latent Ventilation Heat Losses(BTUH) 148 Sensible Ventilation Heat Losses(BTUH) 1148 Hydronic Heat(Linear Ft) 7 TOTAL WINTER HEATING LOAD(BTUH) 4186 Calculated Totals for Entire Structure Size of Structure(Sq.Ft.): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear FL): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractors experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken Into account Correct system sizing Is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 10 of 11 Room Specifications: BATH#2 Room Length(Ft.) 6 Sq.Ft windows facing NE r£NW: — Watts Incandescent Light: 100 Room Width(Ft.) 8 Sq.Ft windows facing South: — Watts Flourescent tight: — Room Height(FL) 8 Sq.Ft windows facing SE&SW: 10 Duct Length from A/H to room: 15 Exposed Wall Length(FL) 6 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(Ft.):— Sq.FL Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: — Number of People in Room: 1 BTUH Appliance Sensible Heat: 1200 Sq.Ft windows facing E&W: — BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenheit) Summer. Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space: 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(AttictCrawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Duct Insulation Factor 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling. .055 Dud Temperature Difference(Winter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab): .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors .500 Air Change Factor(Air change per hour) .5 Windows •900 Space Shading Factor: .4 Air Handler Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear ft 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH) 88 Appliance/Elec Motor Latent Heat Gain(BTUH) 200 Ceiling or Roof Heat Gain(BTUH) 153 Appliance/Elec Motor Sensible Heat Gain(BTUH):1791 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) 43 Glass Heat Gain(BTUH) 189 Ventilation Sensible Gain(BTUH) 80 Exterior Door&North Window Heat Gain(BTUH) 0 Summer Total Latent Heat Gain: 243 Solar Heat Gain(BTUH) 640 Summer Total Sensible Heat Gain(BTUH) 2982 Total Transmission Heat Gain(BTUH) 1070 TOTAL SUMMER COOLING LOAD(BTUH): 3226 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 1030 Latent Ventilation Heat Losses(BTUH) 32 Sensible Ventilation Heat Losses(BTUH) 249 Hydronic Heat(Linear Ft.) 2 TOTAL WINTER HEATING LOAD(BTUH) 1312 Calculated Totals for Entire Structure Size of Structure(Sq.Ft.): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear FL): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional Installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/302014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Detail Report for TANYA SPILLER Room 11 of 11 Room Specifications: HALLWAY Room Length(Ft.) 21 Sq.Ft windows facing NE&NW: — Watts Incandescent Light 100 Room Width(Ft.) 3 Sq.Ft windows facing South: 10 Watts Flourescent Light — Room Height(Ft) 8 Sq.Ft windows facing SE&SW: — Dud Length from A/H to room: 15 Exposed Wall Length(Ft.) 3 Number of Exterior Doors: — Number of Large Electric Motors: — Wall against unconditioned room(Ft):— Sq.Ft Exterior Doors: — Average Electric Motor Horsepower. — Sq.Ft windows facing North: — Number of People in Room: — BTUH Appliance Sensible Heat: — Sq.Ft windows facing E&W: — BTUH Appliance Latent Heat: — Indoor/Outdoor Design Temperatures(degrees Farenhe)t) Summer. Winter. Inside(Thermostat setting) 72 Inside(Thermostat setting) 72 Outside(Above ground): 95 Outside(Above ground 0 Outside(Below ground): 65 Outside(Below ground) 60 Unconditioned Space. 97 Unconditioned Space 65 Above Ceiling(Attic/Crawl Space) 130 Above Ceiling(Attic/Crawl Space) 45 Concrete Slab(Ground temperature) 80 Concrete Slab(Ground temperature) 55 Unconditioned Basement 60 Unconditioned Basement 55 Below Floor Crawl Space 85 Below Floor Crawl Space 50 Applicable Temperatures: Above Ceiling:Attic or Crawl Space Below Floor.Thermostat Setting Exposed Walls:Above Ground Design Conditions Insulation Values(U-Factors) Occupant Sensible Load(BTUH per person) 250 Exposed Walls(Above Ground) .080 Occupant Latent Load(BTUH per person) 200 Exposed Walls(Below Ground) .5 Duct Insulation Factor: 1 Partitions .075 Duct Temperature Difference(Summer) 20 Roof/Ceiling .055 Duct Temperature Difference(Winter) 45 Floor(Above basement) .083 Humidity Difference Inside/Outside%(Summer) 20 Floor(Concrete slab) .001 Humidity Difference Inside/Outside%(Winter) 15 Floor(Between conditioned spaces) .287 Fresh Air Per Person(CFM) 2 Doors •500 Air Change Factor(Air change per hour) .5 Windows .900 Space Shading Factor: .4 Air Handier Design Cooling(CFM per ton) 400 Hydronic Heat(BTUH per linear R 600 Calculated Room Results-Summer Heat Gains Wall Heat Gain(BTUH). 44 Appliance/Elec Motor Latent Heat Gain(BTUH) 0 Ceiling or Roof Heat Gain(BTUH) 201 Appliance/Elec Motor Sensible Heat Gain(BTUH):341 Floor Heat Gain(BTUH) 0 Ventilation Latent Heat Gain(BTUH) 56 Glass Heat Gain(BTUH) 189 Ventilation Sensible Gain(BTUH) 105 Exterior Door&North Window Heat Gain(BTUH) 0 Summer Total Latent Heat Gain: 56 Solar Heat Gain(BTUH) 0 Summer Total Sensible Heat Gain(BTUH) 901 Total Transmission Heat Gain(BTUH) 434 TOTAL SUMMER COOLING LOAD(BTUH) 958 Calculated Room Results-Winter Heat Losses Transmission Heat Losses(BTUH) 871 Latent Ventilation Heat Losses(BTUH) 42 Sensible Ventilation Heat Losses(BTUH) 327 Hydronic Heat(Linear Ft.) 2 TOTAL WINTER HEATING LOAD(BTUH) 1241 Calculated Totals for Entire Structure Size of Structure(Sq.Ft.): 1643 Total Sensible Heat Gain(BTUH): 37332 Total Heat Loss(BTUH): 50599 Total Cooling Gain(BTUH): 43652 Total Hydronic Heat(Linear Ft): 84.33 Total Cooling Requirement(Tons): 3.64 Total Latent Heat Gain(BTUH): 6320 Total Cooling CFM: 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractors experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 10/30/2014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 CALCULATION Heat Load Summary Report for TANYA SPILLER Room Square Heating Loss Hydronic Heat Latent / Sensible Cooling Gain Cooling Cooling Name Ft BTUH Linear Ft. Gain BTUH BTUH Tons CFM KITCHEN 260 11737 19.56 1303 /7296 8599 0.72 287 FAMILY ROOM 228 5332 8.89 604 14861 5465 0.46 182 DINING ROOM 132 3494 5.82 518 /3482 4000 0.33 133 UVING ROOM 273 11254 18.76 1314 /6470 7785 0.65 259 HALUSTAIRS 91 7022 11.7 792 /3343 4135 0.34 138 BATH 48 863 1.44 243 /994 1237 0.1 41 BEDROOM#1 110 1760 2.93 298 /1437 1735 0.14 58 BEDROOM#2 169 2400 4 351 11790 2141 0.18 71 BEDROOM#3 221 4186 6.98 598 13776 4374 0.36 146 BATH#2 48 1312 2.19 243 /2982 3225 0.27 107 HALLWAY 63 1241 2.07 56 /901 958 0.08 32 TOTALS 1643 50599 84.33 6320 / 37332 43652 3.64 1454 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather.customer usage.dud installation.and structure design may vary on each estimate and should be taken into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements.not just total BTUs. Prepared 1 MM014 using O'Brien Quick Loads Pro-Version 1.01-SN:QP-070101-30609 R�PRENCF _mAp6 Tp A MAP ENT►TLE6"CASE HILL,70ME A-2o PLD'r PLAtA PRbPlaR-Ty or- R..SK. CONTIQPCrORS 8 PLI_Fq "4T VALLEY R0Ab j SaVTN WIN4So14. CoNN. -)W-E52. REV, lo-14-52.,1-11-83 ,4-7-83 , 1-IS-8s�WcEK EN6inIEE/�1�6 Assoc- I IBC aJ 1J(F N SULL1VAtl �'�Z N►c ,o 1-IAVENS 'SIB-4 0" E I N(G ,o C06G SHALL .o ev 0 Of z � i �nTnTmn„� JIts 7- 1 47 4 ,7 �6' 'PCnCH 9 oil 'v0.6293 RF,STiv W ,I FFG I 4nnJai y i+ua++ao :0 M tt' _ .����aF CONN, gyp%0 r I y��P��vL "f. I LAW-all' R: 50 00 , RNa82,33 O 130 'O���u�uuNiuunu►►+\ L.P. z.P I ' gPPll'C'ANT• CASE HILL CIRCLE k. S.K. COLITF-AG.Tc^16 'LuL- 0 So ELU► Groh RbwO l SOVTH WINOSOR C-T I 2-DI-b;;'--k-W 6 l I ss.h F{ ZONE A-Z0 -TF I?%.V FL 17_\.O _- _ PRoPERT�I OF R S K. CO►aTRA��-S '�*►C U S s CrkS1r HILL CIRCLE SDUTH W 1 m6 So R CT LUCEK ENGINEERING ASSOC. INC 147. REVISIONS DATE SCALE 1": ypl i D,IE II-30-83 i CONSULT)NG ENGINEERS NO MUCKLANO ROAD DMAah MLQ r��ECKfE EW�- i 9OUTH w"tosok. CONK. - 203-644.2474 ►IIOJECTa-1- �� SHEE1 I CIF I t 1 HEREBY CERTIFY THAT THIS MAP AND SURVEY WERE PREPARED IN ACCORDANCE WITH �E STANDARDS OF A CLASS A-L SURVEY AS D[Ff�tiED IN THE EXISTING "CODE 0 A E FOR STANDARDS OF ACCURACY Of SURVEYS AND MAPS". ADO"ED BY THE 0 UT ASSOCIATION OF LAND SURVEYORS INC. FOR QU IL044C, PVkPoSE.S oNL llb,W APPROVED TOI".f'\1 O'" ^..^; '7'' ` WINDSOR UNGINE:7.-ZING DEPARTMENT DATE: SIG., /,tom ^eference is made to map entitled "Case HILL': Zone A-20 Plot Plan , ?roperty of R S K Contractors , Pleasant Val.lay Road, South Windsor , Conn ; 8- 14-82 Rev 10-14-82, 1-17-83 , 4-7-83 , 7-13-83 , Lucek Engin- eering -Assoc Inc " O CONNE� 4�-30"E 10' Sy. 4" "0 �= 16°0(o-4-0" SS�ONAL E� w L_ 14.0 6 L= 4.41 ""�vuu�uuuuu� I Z 4 M \ — _ t�5. IZb Ln in � o � ro 23'y $_SyZ � f lfl N �FG I Z s N IZZ SO•aL. p '8 'r - F� ,_ c0in 0 CD Ln co to .it. f �'— 93.90` d aC �. Z,-So"e MS. Applicant -j �� ------ R. S.K. Contractors Inc 1750 Ellington Road } . c South Windsor , Ct. 203-644-8761 - Zone A-20 Property of R. S.K. Contractors Inc . 'A2S Case Hill Circle South Windsor, Ct. LUCEK. -ENGINEERING ASSOC. INC. NO. REVISIONS DATE SCALE 1"=40 ' CONSULTING ENGINEERS AP-0 /UCKLAND ROAD DRAWN m10 CHECKED eWl SOUTH WINMR. CONN. 203-"A-247/ ►ROJECT82-19 SHEET 1 1 HEREBY CERTIFY THAT THIS MAP AND SURVEY WERE PREPARED IN. ACCORDAN E Wff HE STANDARDS OF A CLASS _._.1 SURVEY AS DEFINED IN THE EXISTING "CO F P ICE FOR STANDARDS OF ACCURACY OF SURVEYS AND MAPS". ADOPTED BY N TICU ASSOCIATION OF LAND SURVEYORS INC. FOR BUILDING PURPOSES ONL Certified to Richard 0. & Fern *L. Canfield, The' Berlin Savings Bank, and The Connecticut Attorneys Title Insurarice ,ompany. .Cettified sRibstantially- correct Foundation located as .shown. No zoning- violations with respect to location of building Reference is made to a map .en_tialed "Case Hill Zone A-20 Plot Plan, Proneru-r of R. S.K. Contractors., Pleasant•.Val-ley -Road, South Windsor, Conn.. Rev. ; 10-14-82, 1717-83, 4=77 7-13-33, Lucek Engineering Associates r • a r r l s .4,_ i� y i ' Its°-ob `A=•b3°=3�'!:YH„ /6 \ ` I L_1".0G' L'=y.,x{fit f r ._. 36 32: tv LO �G,� �• 2� ,a Zyr N aCO ..�• . •.f Rr.s. � Or- S `a -•� - - Property---of Richard 0. & Fern L. Canfield Lot.-No. 3 Casa Hill Circle -South Windsor, CT Nt M0. T� SCALE"=40' D-wtc10-24-$ �Us •!lDAA► - DRAWN MI LO I cH ECK ED saiurw = amm taw. -- 2064444474 , ` , nrwR�e$3-10 • � eaw `arR1.i ilr^-_ D + �i = DEMO i0_ A '� Q S E S.:ONL Y �.. M MAY 0 5 IY98 South Windsor BUILDING DEPARTMENT 10 THE BUILINK Utei. 1,,..,, . This certified that this plan and specific.liras ... copies of the proposed building or alleratfuns to it erected at together with amendments stated in applicition ..o I fled with plan and I agree to comply with all zonin. iuilding and state laws and such orders as shall tr issued by the a ding Department during pendency of fhls applic io and final issuance of a buildins permit. ed s plan Is approved ubjeet to the �Mjl orders and ordinances regulating building sbill be cony i with.Conditolioonally Approved chess filed w11A Building Inspector Clerl{ CEKT{rtLAflJi� OF ZONING COMPLIANCE Proposed building(s), use(s) andjo')s troucture(s' as shown on this plan app ,:onformance with current 13.).ith• Wik.d egulations. Varianc-es and special exceptio:: ,nay apply• 'Date s � E o cement Officer 6y- 129,— Certified to Richard 0. & Fern �L. Canfield, The Berlin Savings Bank, and The Connecticut Attorfteys Title Lnsurance ;ompany. -Certified s«bstantially. correct . Foundation located as .shown. No zoning violations with respect to location of building , Reference is made- to a map .gn-.titled "Case Hill Zone A-20 Plot Plan, Pronerc- of R. S. K. Contractors , P1eas.ant...Valley Road, South Windsor, Conn.. ; 8-14-82 Rev. ; 10-14-82 , 1-17-8t3 , 4-7-83,..7-13-33 , Lucek Engineering Associates Iv-, . " .. 4 . Ile O D NE 6.y5 s' M.S. I7 /76��. `:Iu.C�' r 3 r 3Z I n,� S RAG,- • w N ,.Z. Ci 00 zE • ••r M.S. � 01 SE � Property of c.ichard 0. & Fern. L. Canfield � Lot No. 3 Casa Hill Circle -South Windsor, CT IL a OC. INC scALIE1"=40' oATc10-24-8 COWNUM DRAWN no I046cM EWI. Bain aWML to�� so�ss�isM $3-10 so I llKMY CEiFM '�' ll�; :T is �. �: �i [_ :•.1f m _ THE !�! IMDbil AGE;">PZ�RPpSES.. ONI,Y 1iL* 111191V MAY :.� i 19,/ South Windsor BUILDING DEPARTMENT CONtP1-iA�CE OF ZONING structure: 147 andlor be 4tK i�r iVA 1 usetsl ` .d buticiing�slt Ian aPpearlSl to Rrupc n on this P gfluth W,nd� a� dot ance W ithCes and Speurren cial except cs;= c9n{®ram Harlan r®�ulatlons� M&Y 590y, a, -, TO TOE BUILDING DEPT. TOWN OF Date 7nt p{{icer This certified thatthi SUUTNEn o merecles ted oit the ProPofedpbuildin andsPecificationf ars trua i or alterations t0 Ux)G � t�s" I a 1 P ther with C�'e amen �'�� $fr the ding awith nd n and d agree to�m ated In •PPlicatlon �t B uil 'ssuetl state laws and such Ply Withall zonint. by the Building Departmen as shall b, Permit application •ntl final issuance during oency 8 pen of a bulldinE G Signed This Plan is approved `Orders ees subject eo and ortllnan to the condition ^Plied with. regulating buildingthat COnditio aAall I» pally Approved JAaaa }hled with dins InspMftr Cat. Certified to Richard 0. & Fern L. Canfield, The Berlin Savings Bank, and The Connecticut Attorneys Title Tnsurance Company. Certified substantially correct. Foundation located as .shown. No zoning violations with respect Lo location of building Reference is made. to a map grktitled "Case Fill Zone A-20 Plot Plan, Prooert-, of R. S. K. Contractors , Pleasant....'Valley Road, South Windsor, Conn. ; B-14-8 ' Rev. ; 10-14-82 , 1-17-8ti3, 4-7-83,.' 7-13-33, Lucek Engineering Associates Tr).: . " {.P. I.P. It 6.y5 A. IV-06-yo" A= 63°--3 44„ \ rz = Sc,00l y= yc. o0 I L 0�0' , 2 O ram- 3 �► 3 Z I O`, I W Vio 2 Z'_/N .�'1 �n m CO ; s Lc CCjr•11,,. si Cr 4AMW*� \�� 4�41lNlll,i11t1111`I' "'``` Cp �E Property of �.ichard 0. & Fern L. Canfield � Lot No. 3 Casa Hill CirNEE cle South Windsor , CT t �± sca►u111=40 ' oATc10-24-f3 CO�LYtti O .��........— atAwM 1rIL0 {C"6CK60 EG1I. SOWN WOOMM Cow. -10 THE :;►Stier t Mri"If CFJFM i�ikl°I A - URPQSES.. O _...�. TO THE BUILDING DEPT. TOWN OF SOUTH W►NDSOR This eertiticd that this plan and Speti/iribns are troe ss o:tth• proposed building or alterations to be together with amendments flied with 1.,n stated In appllcatlan and P and 1 agree to eomply with Building all Zoning, entl State a., end such orders as shall tw ISSued by the Building Department during Pendency of this application and final Issuance of a builditae Permit. 3 SismW TAM pisn IS approved Subject to the condition hst •xaelti and thrdlnanees regulating building Shall t be COrWISIOnsi4 Approtred These filed MIq BYII�jaK CI"* Ift Oatt .^eference is made to map entitled "Case HILL" Zone A-20 Plot Plan, . Property of R. S.K. Contractors , Pleasant Valley Road, South Windsor, ti Conn. ; 8-14-82 Rev. 10-14-82, 1-17-83 , 4-7-83 , 7-13-83 , Lucek Engin- eering Assoc. Inc. " . O dF ��' - �Z•? N Z4R- 0 =30"E-► I.P. N. * 3 Zto ` %%6.4S% MS E r � \`10' Sy. ..,L= 160 064-4-06. R_40.001-44�� w ` --IZ4 :0 2) Ln ' in i 36. r S.► ,n �` /Z.3 .y e IZZ flL. .D Oco , OD cr N M5. rnWhI - -- _3Z.-So'E C11; Applicant R.S.K. Contactors Inc 1750 Ellington Road South Windsor, Ct. \ No G293 203-644-8761 �FE;,.. :�tO -• Zone A-20 Property of R.S.K. Contractors Inc. Z5_ Case Hill Circle South Windsor, Ct. LUCEK, -ENGINEERING ASSOC. INC. NO. REVISIONS" DATE SCAL[ 1"-40 - DAtE CONSULTING ENGINEERS I A-Z C&RT' A 490 NUCKLAND ROAD Z L1r DRAWN M10 CHECKED eWl SOUTH WINDSOR. CONN. 203-to-2474 FROJECT82._19 SHEET 1 I HEREBY CERTIFY THAT THIS MAP AND SURVEY WERE PREPARED IN. ACCORDA E WIT HE STANDARDS OF A CLASS A—Z SURVEY AS DEFINED IN THE EXISTING ..CO F P ICE FOR STANDARDS OF ACCURACY OF SURVEYS AND MAPS". ADOPTED BY N TICU ASSOCIATION OF LAND SURVEYORS INC. FOR B11ILDING PURPOSES 0NE - f V i 0 A TOWN OF S[aUTH �"1INDSOR ENGINEERING DEPARTMENT DATE: SIG.: DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby. TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPRO TV 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# Date Building Inspector -,I) I I Application must be printed or typed FEE SCHEDULE _ / Location of Job: C` I C, $0-$1,000=$15.00 Street o. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Gl1��e e APPLICANT ADDRESS APPLICANT PHONE# ` O W N S At. OWNER OWNER ADDRESS ( 11 �p_ ���� Gi t✓ -- Fes, OWNER PHONE C ESTIMATED COST$ � � V .�, IS THIS A CONTRACT COST? _Yes _ FEE ENCLOSED$ � j ANSOR•C0 TYPE OF JOB: e w Ins teration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) PRESIDENTIAL OF B ING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑NO SINESSCURRENT USE AND OCCUPANCY SEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CON CTO S LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 1700546 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 10/11/2017 GIS ID: 17700025 FEE: 414.00 MUNIS APPLICATION# 201701397 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: DAVE SWEET ADDRESS: 25 CASE HILL CIRCLE ADDRESS: 640 FOREST STREET OWNER: SPILLER TANYA A EAST HARTFORD,CT 06118 25 CASE HILL CIRCLE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REMOVE VINYL SIDING,INSTALL TYVEK PAPER,MASTIC VINYL 26 SQ 5 PAIRS OF SHUTTERS,NEW GUTTERS AND HEADERS. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 10/11/2017 9:52 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1400513 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 11/21/2014 GIS ID: 17700025 FEE: 75.00 MUNIS APPLICATION# 201401599 BUILDING DESCRIPTION: APPLICANT, LOCATION NAME: POWERS HEATING AND COOLING ADDRESS: 25 CASE HILL CIRCLE ADDRESS: 94 ABBOT ROAD OWNER: SPILLER TANYA A ELLINGTON,CT 06029 25 CASE HILL CIRCLE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALL GAS BOILER AND 40 GALLON INDIRECT HOT WATER STORAGE TANK. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 11/21/2014 3:29 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE