Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
25 BRIGHTMAN CIR
Electric # APPLICATION FOR BUILDING PERMIT HVACPlumbi## 25 Brightman Circle Date: <- Sprinkler# 31891 Estimated Cost $ o w a o Building AL APPROVALS _ _ — permit Fee $-aa��p Engineering COMPLETE RED BOXED AREAS Occupancy Fee $ g TYPE OR PRINT ONLY En Ins Fee $ 3_S0O Affidavit CO. SIGN ON REVERSE SIDE g p pp - I Total Fee $ TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant jRS/<—Ke//co =,i, __ Location of Work,;7? �,mh�j,, Cl rr/C- Lot No. -3 Applicant's Address IZYq - Tel.# ?/.D tf J6 Town S / Zip d tiO7 Lic.#-7.7Z Owner Architect Owner's Address Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit 60 _/i I-Lo C•,yl,� �; r City WateaBr Wello Septic System❑ Sewers Ins: HO SP -Cert. Area Basement Garage _ Approved by Date O S Use Group Construction Type Revised W02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be ed the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in th building and Its use is allowed Signed 1 hereby apply for a Certificate of Occu cy for the work described W4is application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS RECMVED FEB 2 406 SITE COMPLIANCE CHECKLIST 1��1 TOWN of SOUTH WINDSOR, CONNECTICUT G/QDTH�� rJjUK �eoo PLE,;fyi;rG DEPT. 25 BRIGHTMAN CIRCLE LOT_t_= Reviewed By D �� �`f Bering) RSK-KELLCO, INC. Date Reviewed Approve /Denied 1744 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By 1 nning) BP_# 32057 Ph_# (860)644-8761 Date Reviewe L ppro /Denied Date Submitted 00/00/00 ***** FOR C Of ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include Approved Denied N/A 1 Approved building permit plan 2. Finish grading per approved / building permit plan t/ 3 Site work; i e trees, shrubs, dumpsters, required parking 4 Utility location; a. sanitary sewer/septic system b foundation drain ✓ c. electrical & telephone d. water e other 6AS 5 Sewer connection charge paid 6 Appropriate certification 7 Bonding 8 Planning & Zoning/ Inland Wetlands Considerations A. Lighting B Signage Freestanding Wall C. Fee in lieu of Open Space /I__ Sewer Permit No. Pav Exc # COMMENTS$ .70 0 0 JO✓I d - V 1 cad -A-5-I/A 11 rt Status N NOTES: 1. PARCEL ZONED AA-30. 2. THIS MAP IS DEPENDENT UPON THE MAPS REFERENCED HEREON. 3. THE PURPOSE OF THIS MAP IS TO DEF;CT THE AS-BUILT CONDITIONS OF LOT 3 - 25 BRIGHTMAN CIRCLE AND FOR THAT PURPOSE ONLY. 4. UTILITY LOCATION AND ELEVATION INFORMATION TAKEN FROM REPORT PROVIDED BY CONTRACTOR. 5. LOT 3 - 25 BRIGHTMAN CIRCLE CONFORMS TO ZONING REQUIREMENTS IN RESPECT TO LOCATION. 1 CGS No 93 MAP REFERENCE: 9 / BOUNDARY INFORMATION IS TAKEN FROM PLANS ENTITLED "BRIGHTMAN CIRCLE, N TRAII v CONVENTIONAL RE-SUBDIVISION, MILLER ROAD & NEVERS ROAD, SOUTH WINDSOR, PAD _ / CONNECTICUT. PREPARED FOR RSK-KELLCO, INC. BY DESIGN PROFESSIONALS, INC., ,� MP—EASEMENT _1S8TOg'3g-E DATE: OCTOBER 27. 2004 REV. TO: 03/25/05, SHEETS 5-9. 9e'STREET TREE EASEMENT ♦ =�� —�� N FAVOR OF ♦ / �Qr TOWN OF SOUTH WINDSOR 4S / 21Y SY./ ' MV 187.7 11 TS X X2022 a -0. FV Tar.MyD 4s � 117 Fs93 a 1.4. 0 Tar X202.5 / %L �'� dNN �UUJVAN TYPE "'C' X2M3 1 ` 1 caw- w� 4 A52714 it ' / X207.0 0. NV.190.83(lS-) / 1 ♦���♦ M7AP 111163 / 191.1 6' 1 w RAVE- � /LOT 3 / EX. SMH X2030/ I TF:197.33 utv • S Y. 1 INV 1 � NV 86:8(OU 1 �// S.Y. -4I I 186. OUT) O� S�D i /1 i NO8'06 05 E t I 1. THIS NDTEs � _ I 1. THIS SUtvElf AND MAP HAS KEN PREPARED N ACCOEDANCE VAIN SECTIONS 20-Joos-t n+Ru 2o-Joor,-2o _ _ I � �� 17.14' 19288' TO IP...._ UL OF THE RECA11ONS OF CONNECTICUT STATE AGENCIES- ''STANDARDS FOR SURVEYSN AND NAPS THE STATE - - - - - - - - 1 48'27-W OF CONNECTICUT.PREPARED AND ADOPTED BY THE CONNECTICUT ASSOCIATON OF LAND SURVEYORS.NC..SEPTEMBER 26,1996. Z _ O ♦TYPE OF SUtKY IS AN IMPROVEMENT LOCATION SURVEY-RECORD-AND IS INTENDED TO DEPICT TTE LOCATION OF IMPROVEMENTS RElAT1VE TO PROPERTY LINES E THIS IS A DEPENDENT RESURVEY BASED ON NAP RUERENCE/I. ♦HORIZONTAL ACCURACY MEM MSS A-2 STANDARDS AND VERTICAL ACCURACY MEETS MSS T-2 STANDARDS TO 1TE BEST KNOVILEDCE AND MJEF. THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. OWNER APPLICANT: KbX-KLLLW1744 ELLINGTON ROAD SOUTH VANDSOR, CT 06074 12327 TEL (860) 644-8761 LAYS04CE R.GEISSLEt.JR. LIC.No, Too. 860-291-8755 RECORD AS-BUILT 1.U I.M OTHERWISE NOTED.E115TN6 UTILITY REVISIONS Den �T�, Fox 860.291.8757 SURLY PREPARED fDl� GEHERAL LOCATIONS AS SHORN ARE BASED ON GRAPHIC SCALE eS'�� /a �JI SHEET ""B KO vatini ALL EXIVOR MG ONSTRU 40 0 ZD 40 LOT #3 LOCAMM BAP 2.RU BE`�D 1O V "�'° Srofessionals, Inc.i ALL UItJlES AIIE 10 BE STAxED N 1HE FE1.DBY A LICENSED LAD SURVEYOR PRIOR TO 2 6/29/D6 ADD SAM.NYS&S3[XWALX ►I4A OF DONSTRI.Xmm ' civil ongin�er• • planners • eurvoyore 25 BRIGHTlr M CIRCLE 3.THts PLAN IS NVA D UNLESS IT BEARS TIE 1 5/09� ADD FINAL GRADING M1A pPA/V B>t qAC �EI9 AQ:/!AT eAPRMON SEAL 00 ORIGINAL SI�,11� 1 iIICh = 40 1IL landscape architects -gle •Spa OF THE PROFESSIONAL 0004EDI/SURVEYOR. NO. DATE DESCRI1107K7N 8Y 165 South Satellite Road. South Windsor. Connecticut 06074 SOUTH WINDSOR CONNECTK= rwrRw or XE I DAIE 00-23-OF 'C9 e(949, 0$4/1 JUN 2 9 South Windsor BUILDING')EPARTMENr is shad t-- pe-31 the t a igr ad b�Aioing 6 FNOTES: AMWF DUM 1. THIS MAP IS DEPENDENT ON THE MAP REFERENCED HEREON. P-M� LEGEND 2. THE BUILDING LOT SHALL BE LOAMED, SEEDED, AND MULCHED WITH STRAW PRIOR TO IKC AM 0 IRON PIN TO BE SET ISSUANCE OF C.O. (IF THE SEASON DOES NOT PERMIT SEEDING, THEN THE LOT MUST BE o MONUMENT TO BE SET STABILIZED WITH STRAW OR EROSION CONTROL NETTING TO PREVENT WINTER AND SPRING = 4!3= = EXISTING CATCH BASIN AND PIPE EROSION). PROPERLY INSTALLED EROSION AND SEDIMENT CONTROLS MUST BE IN PLACE TO - Q - EXISTING SANITARY MANHOLE AND PIPE CONTROL ANY EROSION AND SEDIME;TATION PROBLEMS. THE BUILDER/OWNER IS AKc� —C—PROP. GAS SERVICE RESPONSIBLE FOR ALL STABILIZATION REQUIREMENTS. WAKC ww —S—PROP. 6' SAN. LATERAL (S-2%MIN.) —W—PROP. WATER SERVICE 3. ROOF LEADERS TO BE DISCHARGED ON SPLASH PADS. —F—PROP. 6' PVC FND. DRAIN (S-1.0%MIN.) SUPOMW--� -330- EXISTING CONTOUR 4. ALL ROADWAY UTILITIES ARE TO BE INSTALLED IN COMPLIANCE WITH THE APPROVED --ET0-PROPOSED CONTOUR •BRIGHTMAN CIRCLE* SUBDIVISION PLANS. x9Ln PROPOSED SPOT GRADE EXISTING TREELINE 5. FINISHED GRADING A"OUND THE HOUSE SHALL ALLOW A 3 INCH DROP IN GRADE AT A — — — EASEMENT BOUNDARY DISTANCE OF 6 FEET FROI„ THE FOUNDATION AS SPECIFIED IN THE STATE OF CONNECTICUT — — --+ SILT FENCE BASIC BUILDING CODE N Lm q.EAM01lT 6. PARCEL ZONED AA-30. ' TYPE I 7. BACKWATER PREVENTION VALVE WITH SURFACE ACCESS SHALL BE PROVIDED ON THE r�� FOUNDATION DRAIN. 9 44 I S87 09'38•E i ► REFERENCE NOTE: �' ��'��� CLdcP EA E , ` 22����.. _—�_ ► 0' S T TREE EASEMENT , BOUNDARY AND TOPOGRAPHIC INFORMATION ARE TAKEN FROM PLANS ENTITLED , FA v OF 'BRIGHTMAN CIRCLE, CONVENTIONAL RE-SUBDIVISION, MILLER ROAD & �� WN OF TH WINDSOR' NEVERS ROAD, SOUTH WINDSOR, CONNECTICUT, PREPARED FOR RSK-KELLCO, INC. BY DTIESS N PROFESSIONALS. INC., DATE: OCTOBER 27. 2004 REV. TO: 03/25/05. m s� �, / , Y0• Z INV:187,17 4H X 2 251IN J ► l I I �, HrT n� , V, / p 1.SET POSTS AIO 2 r�_r THE SILT 8 1 �y�I !� ry 00•1 D�UPSLOOPPE� EXCAVATE A D•d•TROOC H EETxJND TO THE ? " / PROP. HOUSE 2 / ti DS FOR STN.UTY PT WSUGPE FROM POSTS LT CO Dr THE POST I TOW:202.00 IAND SEV- OXAMING r FF:203.00 I I 97 F 1Y MIN. , GAR:201.00 L J f ► 'D .527 sq. tL I jel ANTI-TRACKING APRON 2 ®® 0.76 acres ► �I r�� 'lolr'1 N Ali 6'-2• STONE OVER 781 I 20 MAP 113 I ► FILTER FABRIC •, ' 202 ► Bl 116 I ► ' r I F I LOT 3 1 ► ' I ' I / v r ► 1 ATTACH FILTER FABRIC TO �.BACORL 1fE F ILTERTHE RIDDEN POSTS AND EXTEND TRENCH NO CDNPACT ' / 1 ► r FIT INTO M TRENCH THE EXCAVATED SC:L It / 200.29 X g ► I COUP _ i ' 1 o� i tt eALTuu I o1 ' i 20' S. �� r ► r � . - I I SILT r ENCE (TYP.) r 1 I ' N08g6 0 E ► I 1 CONSTRUCTION OF SYNTHETIC FILTER BARRIER S , CB#4 I NS7ti9 36'w ' 1 1 1192a6• TO IP N.T.S. - _ _ _ - _ _ - - _ / TYPE .0 1 ► + T 48'127 1 i o (F:197.33 I ► / I I I rP .`.: -% INV.190.83(18') 191.13(6') / , TU THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20-300D-1 THRU 20-300D-20 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES - -MINIMUM STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT' AS ENDORSED SY THE CONNECTICUT ASSOCIATION OF LAND SURVEYDRS. INC. AND CONFORMING TO HORIZONTAL ACCURACY CLASS A-2 AND VERTICAL ACCURACY CLASS T-2. TO THE BEST OF MY KNOWLEDGE A ELIEF, THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. ;;%APPLICANT: 12882 1744 EWNGTON ROAD RICHARD P. MARTEL UC. No. SOUTH WINDSOR. CT 06074 TEL. (860) 644-8761 Tel. 860.291.8757 ��® 1.UNLESS OTHEFMSE NOTED.EIDSTM UTILITY REVISIONS DEPENDENT RESURVEY PREPARED FOR: LOCATIONS INFORMATION. SHORN ARE LASED ON GRAPHIC SCALE � Fox 860•291.8757 E SHEET ASHOU D DE FIELD AVERIFIED PRIER TO NCUTILITIES /SITR ECTRIEL 40 0 20 40 esign Lo?' >a�3 LOC A (1 CH HAD 1 B ALL KISSUTILITIES ARE TO DE STAKED IN THE FIELD rofessionais Inc. BY A CIONSIRUCTI FN lANO SUItvEYOR PPoOR TO 17HIS PLAN. 7.5 BRIGHTMAN CIRCLE of i TNs PLAN Is INVALID UNLESS R BEARS 111E = 40 ft. 1 civil •nRinaars • planne,rs . surveyors A¢tw Br.- RUF ,,qL MR:►lKtT AWRESSION SEAL AND ORIGINAL SIGNATURE I inch landscape, architects • Cis .Cps OF THE PROFESSIONAL ENGIIEEFR/SURVEYOR. NO. DATE DESCRIPTION BY SOUTH WINDSOR 165 South Satellite Rood South Wind9or Connecticut 06074 CONNECTICUT or clvs DATE.•08-041-03 9 2NS LO AUG 19 2005 ING DEPtAl-PTNIENT SOUTH EtVGltvESRvv,1NDSOR NG DEpT fie t. It 4-A I C, RECEIVE© SITE COMPLIANCE CHECKLIST AUG 1 2005 TOWN of SOUTH WINDSOR, CONNECTICUT e nN•;r 25 BRIGHTMAN CIRCLE LOT_# 3 Reviewed By j3,hSONi��4i�J�fl��i' hey g) RSK-KELLCO, INC Date Reviewed 5011ash- rov Denied 1744 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By anning) BP_#_31891_ Ph_# (860)644-8761 Date ve Reviewe IS' t Approd/_enied Date Submitted 08/19/05 ***** FOR BU LD NG P IT ** * In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval The minimum requirements shall include Approved Denied N/A 1 Name, address & phone number of owner/applicant 2 Name, address & phone number of plan preparer +/ 3 Zoning Information - i e. zone, open space, floodway, street address 4 Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record c Lot description, bearings, building lines, / distances, area, etc. ✓ d. Contours, existing & proposed, 1 or 2 ft interval where appropriate e. Building location with dimensions Elevations of proposed finish floor, garage / floor & centerline of road at driveway f Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street V g. Tentative utility location (gas, water, electric, septic system, etc.) l/ h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements (P.E & L.S ) 5. Sedimentation and erosion control 6 Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WINDSOR PERMIT# A tca ' s hereby: BUILDING DEPARTMENT PROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 001Ae r/;.;C.V APPLICANT ADDRESS d�o CeorrP l P/y ` fS W atsar C 16(no APPLICANT PHONE# 0W N S f OWNER /CU q� OWNER ADDRESS wsr - OWNER PHONE C ESTIMATED COST$ IS THIS A CONTRACT COST? _Yes _No FEE ENCLOSED$ 40, TYPE OZwew O R C Installation Alteration/Addition/Repair Revised 4/01//2002 J APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY O MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL O INSTITUTIONAL O FACTORY ENGINEER'S NAME PHONE O STORAGE ❑GARAGE ADDRESS ❑MDCED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION LVIwr' SIZE OF MAIN DRAIN y NO.OF TOILETS�_STYLE lZuU pi.<<t NO.URINALS STYLE NO.OF BATHTUBS oZ NO.OF SHOWERS I NO.OF LAVATORIES S NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE o� AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW DYES O NO SIZE OF WINDOW Y 3 IF NONE C.F.M.OF VENTILATOR Crm SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN ,l SIZE OF WATER PIPING&RISER WATER HEATER: TYPE J/ 4Vyn MANUFACTURER Pdl-J CA V� DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND ISTO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. a?7� 1-23 CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT - DATE I DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Applicati e TOWN OF SOUTH WINDSOR PERMIT# / BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg. Permit# l -- / 644-2511 ext. 230 at� ""fllector 11 Application must be printed or typed FEE SCHEDULE Lgcation of Job: $0-$1,000=$15.00 FTFenant Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT 1&l�GLI�lI' Q�/ �� ���1 � /12L APPLICANT ADDRESS 74 r 401 6 • d 0 7 APPLICANT PHONE# /�'��^ //5� O W N S OWNER /? S �/< /c 6 G C /1 e- OWNER ADDRESS / 7 y7 `lam f�T 50 O a. OWNER PHONE 67 W-- 976 6 C ESTIMATED COST$ / O a . i � IS THIS A CONTRAC�COST? �—No �G �s✓ FEE ENCLOSED$ 11re j - TYPE OF JO�B• OSOR.COS !/New�Installation Alteration/Addition/Repair Reviced 4/01 innm APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE O UILDING: EATING iCWSIDENTIAL 45:A/C ❑COMMERCIAL ❑ VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC MWARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE O OF INSIDE 75— OF DIFFERENCE 7 Sr- °F TOTAL HEAT LOSS (BTUHo°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH)/d? ZDo,,-NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY 5-GAS—INPUT Bt d41�11--LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING _ DESIGN TEMP.OUTSIDE I?-l--OF INSIDE -7 0 OF DIFFERENCE Z 5 OF TOTAL HEAT GAIN(BTUH)�VWZ--'(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESC E ALL COOLING EQUIPMENT(INCLUDING MAKE& MODEL NO.) _ TONNAGE COOLING CAPACITY(BTUH) I C/ D 4 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) I TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. _ CONTRACTORS LICENSE NO. D TYPE STATE SIGNATURE OF APPLICANT Lot #3 Brightman Circle HVAC Load Calculations for RSK Builders RusiouNMAL i RHVACHVAC LoADe i Prepared By: Steve Smith Advanced Htg&AC Inc. Tuesday, November 08,2005 RhvaC-Residential a Light Commerebi HVAC Loads Elite Software Development,Inc. Advanced Htg&A/C Lot#3 Brightman Circle j South Windsor,CT D6074 Page 37 System 1 Room Load Summary Htg Run Run Clg Clg Clg Zone Clg Air FNName oom Area Sens ' : om Duct Duct Sens Lat Nom Adj Adj Sys SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- 1 Family Rm 266 7,717 100 1-6 609 2,627 478 119 1.00 119 119 2 Foyer 138 3,114 40 1-4 553 1,061 253 48 1.00 48 48 3 Living 150 8,493 110 1-7 492 2,893 637 132 1.00 132 132 4 Dining 168 4,752 62 1-5 591 1,771 318 81 1.25 101 81 5 Entry 144 4,858 63 1-4 622 1,193 393 54 1.00 54 54 6 Pantry 90 2,196 29 1-4 401 770 75 35 1.00 35 35 7 Kitchen 180 2,907 38 1-4 643 1,233 159 56 1.00 56 56 8 Dinette 170 5,260 68 1-7 547 3,215 403 146 1.05 154 146 Zone 1 subtotal 1,306 39,297 511 14,763 2,716 672 699 672 ---Zone 2--- 9 Bed 2 150 4,483 58 1-5 638 1,913 262 87 1.25 109 87 10 Bath 1 66 1,044 14 1-4 196 376 56 17 1.00 17 17 11 Bed 3 155 4,526 59 1-5 645 1,932 262 88 1.00 88 88 12 Bed 4 195 3,868 50 1-5 568 1,702 262 77 1.00 77 77 13 Upper Foyer 182 3,653 47 1-7 451 2,651 234 121 1.25 151 121 14 Bed 5 180 4,325 56 1-5 623 1,868 262 85 1.25 106 85 15 Large Lav 135 2,102 27 1-4 673 1,291 84 59 1.00 59 59 16 Master Suite 1,023 17,902 233 3-6 527 6,819 _ 393 310 1.00 310 310 Zone 2 subtotal 2,086 41,903 545 18,552 1,815 844 917 844 System 1 total 3,392 81,200 1,055 33,315 4,531 1,515 1,616 1,515_ System 1 Main Trunk Size: 16x17 in. Velocity: 858 ft./min Loss per 100 ft.-. 0.078 in.wg Woling System Summary Cooling Sensible/Latent Sensible tent To Tons Split _ Btuh Btuh B Net Required: 3.15 88%/ 12% 33,315 4,531 37,846 Recommended: 3.70 75%/25% 33,315 11,105 44,420 Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh Dennis Davey i.4. O■ wwvr.dcraR5 Vpx wm I�}q Ardatx:L AIA P 860-875.1426 387 Memw Road F $60-870-1072 TOUR d,Cr 06M c 4"CY9,t. -Joct January 16, 2006 RE: Lot-3 Brightman Circle Scott Kelley RSK Kellco Co. 1744 Ellington Road South Windsor, CT 06074 Dear Scott: Subject: Living Room Wall Framing 1 visited the site and reviewed the framing of the Living Room wall for the captioned house. The revision to the wall framing meets appropriate framing and connection requircrncnts specified of the Wood Framing Construction Manual for one and two family dwelling. &se urs, y, A I A Architect Dennis Davey,Inc. Electric # APPLICATION FOR BUILDING PERMIT Plumbing# I2450 25 Brightman Circle Date: 5��,�f. Z� 200 HVAC # t X w`'I 1 r Sprinkler# 32057 FINAL APPROVALS - --- Estimated Cost $4z5, 7,0. lI� Building - --- - Permit Fee $_, -//rEngineering COMPLETE RED BOXED AREAS Occupancy Fee $ 'co/Q,' g go Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee Appr. for CO. ► SIGN ON REVERSE SIDE - J Total Fee $ TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant Location of Work Lot No.,� Applicant's Address17,Vy _ i/ o o,, oa Tel.#F,0-6 e76/ Town—_�SZrA h Zip 0,6 0 / Lic.# .2& Owner Sri we Architect e2sLq-n Owner's Address Architect's Address IzZ12- 1,)h ?Jdd Zip om har A16 Zip, Sq. Ft. New Area: 1 st FI. /,s 23 2nd Fl. 1331 3rd FI. Total New Area-2 I1,1 Purpose of this permit �QJPr cJ /�d�Ae- (.?n� L d(-L',all , F(1i n ja4f l IjIn :7t�r11 1 /)us lI/ Fmrnr�m�I�`l� �.,i C_l.�cc.��l/suS Q e o T 7�G City Watery' Well❑ Septic System❑ Sewece-' Ins: HO SP Cert. Area X 76 Baseme ! /�7� Garage Approved by Date Use Group Construction Type Revised W02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in wh this building and its use is allowed. Signed I hereby apply for a Certificate of Occ y for the work desctibeS4 this application for the permit. Signed DO NOT WRITE BELOW THIS L INSPECTION COMMENTS I I NOTES: 1. THIS SURVEY AND MAP HAS BEEN PREPARED IN ACCORDANCE WITH SECTIONS 20 30OB-1 THRU 20-30OB-20 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES — "MINIMUM STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF {®T CONNECTICUT* AS ENDORSED BY THE CONNECTICUT ASSOCIATION OF LAND 1�! SURVEYORS INC. THIS MAP WAS PREPARED FROM RECORD RESEARCH, OTHER MAPS, LIMITED FIELD MEASUREMENTS AND OTHER SOURCES. IT IS NOT TO BE CONSTRUED AS A PROPERTY/BOUNDARY OR LIMITED PROPERTY/BOUNDARY SURVEY AND IS SUBJECT TO SUCH FACTS AS SAID SURVEY MAY DISCLOSE. 7 2. PARCEL ZONED AA-30. 3. THIS MAP IS DEPENDENT UPON THE MAPS REFERENCED HEREON. 4. UNDERGROUND ENCROACHMENTS, STRUCTURES, OR SYSTEMS, IF ANY EXIST, WERE NOT A PART OF THIS SURVEY, EXCEPT AS DEPICTED OR NOTED HEREON. 5. PERIPHERAL PROPERTY LINES OF ADJACENT OWNERS ARE FOR INFORMATIONAL PURPOSES ONLY AND ARE NOT TO BE CONSTRUED AS BEING ACCURATELY LOCATED OR DEPICTED. 6. STONEWALLS, FENCES, LEDGES AND WATERCOURSES MAY DEVIATE SLIGHTLY FROM PRINCIPLE COURSES SHOWN. CGS HAD 83 1 7. ANY ENCROACHMENTS ARE DEPICTED AS SHOWN. 9 8. THE PURPOSE OF THIS MAP IS TO DEPICT THE AS—BUILT CONDITIONS OF TRAM O LOT 3 — 25 BRIGHTMAN CIRCLE AND FOR THAT PURPOSE ONLY. I PAD �" S87.09'38"E 9. UTILITY LOCATION AND ELEVATION INFORMATION TAKEN FROM REPORT PROVIDED ' TEL t0' CLdcP EASEMENT -- 221_3S' 20' STREET TREE EASEMENT —� BY CONTRACTOR. / N FAVOR OF 00 10. LOT 3 — 25 BRIGHTMAN CIRCLE CONFORMS TO ZONING REQUIREMENTS IN RESPECT �� � TOWN OF SOUTH WINDSOR TO LOCATION. 11. FINAL GRADING HAS NOT BEEN COMPLETED. 20'e< ' 12. DRIVEWAY HAS NOT BEEN PAVED. INV:187.17 rAt/ 44N N 114 9.0 �, � / SANITARY 2a' � .1 a N MAP REFERENCE: Q 1 s4• c" . EV ft BOUNDARY INFORMATION IS TAKEN FROM PLANS ENTITLED "BRIGHTMAN CIRCLE, / �� / / Fr z %z ss O ; CONVENTIONAL RE—SUBDIVISION, MILLER ROAD & NEVERS ROAD, SOUTH WINDSOR, s 4.y. CONNECTICUT, PREPARED FOR RSK—KELLCO, INC. BY DESIGN PROFESSIONALS, INC., / �� I �N`% N.4. p t 33,527 s . ft N DATE: OCTOBER 27. 2004 REV. TO: 03/25/05. SHEETS 5-9. N / D��a' + 18,1 0.76 acres ~' J" AN /Y 46 TYPE "C" / F. 3 MAP 113 ' T I BILK 116 TF:197.33 LOT 3 INV-190.83(18-) ICPA VEk ' I Vf IslLo �~ LOCATION MAP S I a 219.93' SILO N87D9'3 "W -� 1 17.14' 19286' TO IP _ O TO THE BEST OF MY KNOWLEDGE AND BELIEF, THIS MAP IS SUBSTANTIALLY CORRECT AS NOTED HEREON. OWNER APPLICANT: 1744 EWNGTON ROAD SOUTH WINDSOR. CT 06074 THOMAS L EVANS. •,O. 18626 TEL (560) 644-8761 RECORD AS--QUILT Tel, 860.291.8755 SURVEY PREPARED FOR: /�(�'���p SHEET 1.UNLESS OTHERWISE NOTED.EXISTING U.UTY REVISIONS Fox 860.291.8757 Ga@E AL LOCATIONS AS SHOWN ARE BASED ON GRAPHIC SCALE .Design AVAILABLE MELD VERIFIED ALL PRIOR TOG LI STRUI- 40 0 zO ,a LOT A3 L0Q%'RGH LUP 1 2.ALL UTILITIES�RE TO B STAKED ro N THE rofessionais Inc. 2 ALL UTRJTIES ARE TO BE STAKED IN THE FIELD BY A LICENSED LAND SLIRVEYOR PRIOR TO l yy r�7 r�p� �T D/1��p OF OONSIRUCTION, civil engineers • planners •surveyors b5 BRIGHTMAN rillL�l�l CIRCLE PRAWV BY- avc .ALB Afa:1sW J 3.THIS PLAN IS INVALID UNLESS IT BEARS ONE "Il wPRESSION SEAL AND ORIGINAL SIGNATURE BY 1 inch = 40 it. landscape architects • gls •gps SOUTH WINDSOR CONNECTICUT er. ME oA>E oa-ss-as Or THE PROFESSIONAL ENCINEER/SURVEYOR. NO. DATE DESCRIPTION 165 South Satellite Road South Windsor. Connecticut 06074 I now Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-32057-B 125,700 E01 SERVICE 12/08/05 JFF A WITH LLOYD OK TO RELEASE TO NU P02 UNDERGROUND 12/07/05 CJD A P03 ROUGH O1/05/05 PJP A W/PIPETRAILS STEVE B03 FRAMING (ROUGH) 01/10/05 PJP D CONT.TIES CJ-RAF,REPLACE CATSOCJ,TRANSFER PON LOADS,STABILIZE FRONT EXT WALL,OK TO INSULATE E03 ROUGH O1/10/05 PJP D DRAFTSTOP FP VENT, B04 INSULATION O1/18/06 JFF A WITH LLOYD R19 WALLS R30 ATTIC NOT BASEMENT FRAMING OK PER DENNIS DAVIES B04 INSULATION O1/19/05 PJP A BASEMENT W/FIREBLOCKING W/LLOYD PO4 GAS TEST O1/20/06 PJP A PRESSURE TEST,FP,RANGE,FURNACE,WATER HEATER B10 FINAL 02/16/06 PJP D W/SCOTT NO ELEC PERMIT,ASBUILT, FCN LEFT Q SITE B10 FINAL 02/24/06 PJP A W/SCOTT,AFF FEE,CORRECTIONS MADE **-12850-P 12,000 **-12841-H 11,500 **-20131-E 4,900 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Applicati ereb : TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT Z cn /_.3/ APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# r 644-2511 ext. 230 Date uil ng Inspector Application must be printed or typed FEE SCHEDULE FTenant � '�j Location of Job: $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT APPLICANT ADDRESS 22-1 el y/ Sj — SO P S�.,� 04,0 51-y - - APPLICANT PHONE# ZC)5''TU Z.0 O W N S Fq OWNER ZZ S K. xee -e j OWNER ADDRESS $, rr OWNER PHONE C C ESTIMATED COST$ rJv x * IS THIS A CONTRACT COS _Yes N l� o4C! FEE ENCLOSED f TYPE OF JOB•' OSOR COO ✓New Installation Alteration/Addition/Repair —Revised 4/01//2002 - APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED A RESIDENTIAL BUILDING PERMIT APPLICATION? ®�U NO ❑BUSINESS I CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE❑EDUCATIONAL FUTURE USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE (3 GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD KQYk-A�6 SIZE OF SERVICE 2-,—,')0 AWS SIZE OF MAIN CONDUCTORS NUMBER OF METERS ! NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK C.�Jcat THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Z- Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-32057-B 125,700 E01 SERVICE 12/08/05 JFF A WITH LLOYD OK TO RELEASE TO NU P02 UNDERGROUND 12/07/05 CJD A P03 ROUGH 01/05/05 PJP A W/PIPETRAILS STEVE B03 FRAMING (ROUGH) 01/10/05 PJP D CONT.TIES CJ-RAF,REPLACE CATS@CJ ,TRANSFER PON LOADS,STABILIZE FRONT EXT WALL,O K TO INSULATE E03 ROUGH 01/10/05 PJP D DRAFTSTOP FP VENT, B04 INSULATION 01/18/06 JFF A WITH LLOYD R19 WALLS R30 ATTIC N OT BASEMENT FRAMING OK PER DENNIS DAVIES B04 INSULATION 01/19/05 PJP A BASEMENT W/FIREBLOCKING W/LLOYD PO4 GAS TEST 01/20/06 PJP A PRESSURE TEST,FP,RANGE,FURNACE,W ATER HEATER B10 FINAL 02/16/06 PJP D W/SCOTT NO ELEC PERMIT,ASBUILT, FCN LEFT @ SITE B10 FINAL 02/24/06 PJP A W/SCOTT,AFF FEE,CORRECTIONS MADE **-12850-P 12,000 **-12841-H 11,500 **-20131-E 4,900 Total Est Value 154,100 Dwelling 2,766 138,991.50 Basement 1, 2 2 , 0 00 64 9,630 Garage 642 ,63 630 00 Smoke Det 7 525 00 BOCA Value 171,009 48 Difference 16,909.48 ll��