HomeMy WebLinkAbout24 HUNTER DR UNIT 32 APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT 160 51 L
APPR V 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230
Date Building Insp or
Application must be printed or typed
FEE SCHEDULE Locations of/Job:
$041,000=$15.00 t \-V Y- X- a
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
U ti1tJ�� �C c
MMAIDRiSS ,
A E ft �
6 tNNEI�' .tom
letOW N 3 Fq� EN �� S 1—` \
Ica
QI
PHNE
EESTIl� COST$
C �
..� U IS THIS A CONTRACT COST? \-/Yes No
VFEE ENCLOSED$ Z•00
° TYPE OF JOB: \4 11
�SOR•C0 New Installation
Alteration/Addition/Repair .
Revised 03/05/10 .
APPLICATION FOR HVAC PERNUT(Continued from-ieverse side)
TYPE 0 SYSTEM: TYPE OF fiUILDING:
HEATING (3 RESIDENTIAL
❑ A/C ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LB41T LBS. HIGH PRESSURE LIMIT LBS.
(3 HYDRONIC Cl WARM AIR ❑ UNIT RADIANT.HEATER
EXISTING RADIATION ADDITIONAL RADIATION �TQTAL RADIATION
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE ' °F
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
\ �Am GAS I-Au L_0 _y P�_
GROSS HEATING CAPACITY{INPUT-BTUH). NET RATING(OUTPUT-BTUH
TYPE OF FUEL
❑/,OU,GPM OIL TANK LOCATION: ❑ .INSIDE ❑ OUTSIDE CAPACITY
LY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&":*ODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION) , n
FURTHER DESCRIPTION OF WORK PeA-Y)()v P
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE STATE
✓
SIGNATURE OF APPLICANT . _ � DATE 1 U /\6/\�
PROPOSAL
Phone: 86C>-529-6813 TOWN OIL CO., INC. CT License#393287
786 Silas Deane Highway
Wethersfield, Connecticut 06109
PROPOSAL SUBMITTED TO: PHONE:644-0531 DATE:10/05/17
MARGO DUCLOS JOB NAME:
24 HUNTER DR STREET:
SOUTH WINDSOR CT06074
CITY,STATE,ZIP CODE:
We hereby submit specifications and estimates for.
WE WILL REMOVE OLD FURNACE AND INSTALL A NEW HEIL MOD# G8MVL0660A 2 STAGE
VARIBLE SPEED BLOWER FURNACE WE WILL INCLUDE ALL TRANSISTION DUCTS, GAS
PIPING, VENT PIPE AND ALL ELECTRICAL TO MAKE A COMPLETE JOB.
You may cancel this contract within three(3)business days after the date you sign IL (Saturday is a business day.) Notice of cancellation must be in
writing and delivered or sent by mail or telegram before midnight on the third business day to(installer)at(installer's address). If you cancel,any
deposit you have paid will be returned to you within ten(10)days of the seller's receipt of your notice of cancellation_
I
�u1l±NA.
r 0
FOR THE SUM Of $ $357156 INCLUDING TAX
TERMS OF PAYMENT $300.00 DOWN PAYMENT BALANCE UPON COMPLETION
This proposal is limited to ten-day acceptance from date hereof.
The contractor shall not be responsible for damage or delay due to strikes,fies,accidents or other causes beyond his reasonable control.
The contractor carries Workmen's Compensation and Public Liability Ireuance,but does not assume risks of any other character under this contract.
After acceptance by the Owner in the space below,this contract shall be binding either upon written approval below by an officer of the contractor or upon commencement of the
work by the Contractor and shall then constitute the entire agreement between the Contractor and the Owner.No oral terms or representations shall be considered a part of this agreement.
A FINANCE CHARGE OF 1%per month,at an ANNUAL PERCENTAGE REATE OF 12%will be c.Farged on delwpuent accounts.In case this octant shall not be paid when due,the Buyer or
Agent thereof promises to pay costs of collection,including a reasonable attorneys fee
ACCEPTED BY
RUB
DATE TITLE President
,E-Z HEATLOSS (95) 6.0 Copyright 1997, Thomas & Associates, Bellaire, MI 49615
(616) 533-8472
TOWN OIL CO. INC.
786 SILAS DEANE HWY.
WETHERSFIELD, CT 06109
860-529-6813
DUCLOS
10-09-2017
24 HUNTER DR
S WINDSOR
Heatloss is based on a Design Temp. Difference of 70
Heatgain is based on a Design Temp Difference of 20 ,with a Dark Roof
CFM for Heatloss is based on a Temp. Rise within the heat exchanger of 50
------------------------------------------------------------------
1ST FL MAIN
CEILING HEIGHT IS 8. FEET, VOLUME IS 9280 CUBIC FEET
10 EXPOSED OPENINGS,TOTALING »»»»»»»»»»» 130. SQUARE FEET
4 EXPOSED WALLS, not including openings,TOTALING »» 974. SQUARE FEET
ROOM SIZE IS 40. LONG by 29. WIDE, TOTALING >> 1160. SQUARE FEET
WINDOW TYPE IS: U-Value = .551, Double Pane, Clear Glass
WALL TYPE IS U-Value = 06, frame, Insulated
CEILING TYPE IS: U-Value = . 033, Unconditioned Attic Space Above
FLOOR TYPE IS: U-Value = . 09, Floor, over Enclosed, Unconditioned space
HEATLOSS HEATGAIN
Additional BTUH for people, Appliances etc. 0 BTUH
The Total BTUH for the outside walls are 4091 1364 BTUH
The Total BTUH for the Exposed Openings are 4338 5871 BTUH
The total BTUH for the ceilings 2668 1740 BTUH
The total BTUH for the floors 3654 0 BTUH
The BTUH infiltration for the openings is 10442 1492 BTUH
DUCT LOSS OR DUCT GAIN for this room is 0 0 BTUH
SENSIBLE HEAT GAIN 10467 BTUH
THE TOTAL BTUH FOR THIS ROOM IS 25193 BTUH
The total CFM of air required for this room is 458 501 CFM
----------------------------------------------------------------
BACK ROOM
CEILING HEIGHT IS 8. FEET, VOLUME IS 1152 CUBIC FEET
3 EXPOSED OPENINGS,TOTALING »»»»»»»»»»» 37 SQUARE FEET
3 EXPOSED WALLS, not including openings,TOTALING »» 251. SQUARE FEET
ROOM SIZE IS 24 LONG by 6. WIDE, TOTALING >> 144 SQUARE FEET
WINDOW TYPE IS: U-Value = .551, Double Pane, Clear Glass
WALL TYPE IS U-Value = .06, frame, Insulated
CEILING TYPE IS U-Value = .033, Unconditioned Attic Space Above
FLOOR TYPE IS: U-Value = .09, Floor, over Enclosed, Unconditioned space
HEATLOSS HEATGAIN
Additional BTUH for people, Appliances etc. 0 BTUH
The Total BTUH for the outside walls are 1054 351 BTUH
The Total BTUH for the Exposed Openings are 1088 1312 BTUH
The total BTUH for the ceilings 331 216 BTUH
The total BTUH for the floors 454 0 BTUH
Page # 1
The BTUH infiltration for the openings is 2972 425 BTUH
DUCT LOSS OR DUCT GAIN for this room is 0 0 BTUH
.SENSIBLE HEAT GAIN 2304 BTUH
THE TOTAL BTUH FOR THIS ROOM IS 5899 BTUH
The total CFM of air required for this room is 107 110 CFM
T O T A L S
VOLUME IS »»»»»»»»»»»»»»»»»»»> 10432 CUBIC FEET
EXPOSED OPENINGS,TOTALING »»»»»»»»»»»»> 167. SQUARE FEET
EXPOSED WALLS,above grade not including openings 1225 SQUARE FEET
TOTAL SQUARE FEET, of walls below grade 0 SQUARE FEET
FLOOR AND CEILING SIZE IS 1304 SQUARE FEET
HEATLOSS HEATGAIN
Additional BTUH for people, Appliances etc. 0 BTUH
The Total BTUH for the walls above grade are 5145 1715 BTUH
The Total BTUH for the walls below grade are 0
The Total BTUH for the Exposed openings are 5426 7183 BTUH
The total BTUH for the ceilings 2999 1956 BTUH
The total BTUH for the floors 4108 0 BTUH
The BTUH infiltration for the openings is 13414 1917 BTUH
DUCT LOSS OR DUCT GAIN 0 0 BTUH
TOTAL SENSIBLE HEAT GAIN 12771 BTUH
LATENT GAIN 2251 BTUH
T O T A L B T U H, T H I S B U I L D I N G 31092 15022 BTUH
The total CFM of air required 565 611 CFM
********************************************************************************