Loading...
HomeMy WebLinkAbout2301-2305 ARTHUR DR BLDG 23 APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT � y0� APPR Bldg.Permit# TE 1540 SULLIVAN AVENUE 1� ;� 644-2511 ext. 230 -}DDOc�2� Dat Building Inspector .,)-,� Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT �,,yNe ,,r7,_yr- 11e7tr A) 6- APPLICANT ADDRESS /3%/ S/Je-- APPLICANT'S PHONE# _6W) 776"jD 4� OWNER �/Cd►#we) WN S qO Fq� OWNER ADDRESS a5 ( 4R17e,;,e Wo OWNER PHONE 42; :;6)Y_a y O * ESTIMATED COST$ � �. 4�� C � IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ TYPE OF JOB: �S0 O CO New Installation Alteration/Addition/Repair �L / Revised 3/05/10 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING RESIDENTIAL A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC 0 WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) r�vix,9AJ 6 gs T r.w rZ /Yla!)e/ "' GROSS HEATING CAPACITY(INPUT-BTUH) V&, 0-fk' NET RATING(OUTPUT-BTUH) 1f 11,LL`r. TYPE OF FUEL ❑ OIL-GPM / OIL TANK LOCATION: ElINSIDE ❑ OUTSIDE CAPACITY y GAS-INPUT 74.pa> LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) 30, D00 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) ,a�"�' Zo��y.j (v� ) � .Sy3 rszN, �-e.ur.»- Zo,�,•e, FURTHER DESCRIPTION OF WORK iSrcS THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE o�6 Deny 1�,< Heat Loss if Heat Gain Analysis Sfar' dC- /C`►!f�'D �'✓SG3.✓ ,;'3 / `�rIT�1L'-` /��' �xrrG z6l" H,JSGI.E' �v "SAc'c -41 Connecticut Heatin-q& Coolinq LLC Heating R Coding Local Humidigr Medium 35 Dselon T.W Olt 70 pp��[q Heating Cooling Load Workshed Latent Condition Grams C0011rg Design Tamp Dif. 15 Load Load T r O'Ins. R113' R196' R301r Ceiling(Sq.Ft) X Hosang 4LO 6.2 17 is is ii 7 t X coaling 17.0 12 2.1 1.3 = wall(Sq.Ft) �L Window(Sq.Ft) N Single Double Triple use 7 x Cooling 29 22 1s = multiplier for inside shade S Single Double Tip le -- x Cooling u 37 n = E Single Double Triple X Cooling 85 72 58 = W Single Double Triple X Cooling 95 72 56 = Single Double Double wlSt, _ Total Glass Sq.FL � X Hooting 91 94 37 - FD 6 Sliding Doors Single Double Triple N X cooling 29 22 18 = use.7 S X Coding 44 37 27 = multiplier E X Cooing 95 72 56 for inside W X cooing 85 72 56 = shade Single Single/St Double X Nesting 99 51 97 Wood WlSlwm urethane Ulstorm Sq Ft Dogs x Nesting 72 5. Is 3 X cooling 9.6 5.7 15 3.0 Frame Cr Ins. R-11 3' R-fS R-19 6' Net Wag !X' X Mating H U 4a 19 ` &I(C I x Coding 5.0 1.7 1.5 1.0 = �•L� Mail(Above Grads) 0'irnwl R-5,1'insul R-11,3-foul R-19.6'Insul Not Wall X Mooting 36 1 .9 . X Cooling 5.9 1.6.8 0 0 .9 .5 Masonry(Below Grade) Or insul R-5,1'insul R-11,3'insul R-19,6'Insul Net Wall X Nosing 10.3 6.1 4.2 2.9 Sq.Feat Basement floor / X N-Wng 2.0 `�)•j Stab WIO Linear Fast 0'Edge insul 1'Edge timid 2'Edge insul Perimeter System -:] X Nosing 57 29 N.7 Slab With Linear Feat Or Edge insul 1'Edge insul 2'Edge maul Perimeter System - x Mssing 133 so 96 - Floor Over Sq Feet 0'insul R-11,3'insul R-19,6'insul R-30,10'maul Unconditioned X olling 72 11.8 3.9 2.6 = Space itCooling 3.9 0.8 O.S 0.4 = Infiltration In X Hooting TT y/ (LxWxHl60x.5) 3-1) x Cooling 17 = Mechanical X Heating T7 = Ventilation X Cooling 17 s Kitchen Allowance - 1200 X Cooling 300 Sensible Load = s of people X Cooling 230 tamm Load i Latent Loads Infil+Mach Vent X 0.68 x 35 Grain = Heating Input Requirements Cooling Input Requirements Latent Load Sensible Load Totals 1-Heating Load Output I )87 Cooling Sensible Load I=SHR Subtotal 2-Heating Load Output I B 95 Duct Loss x 1.15 x 1.15 Total Load "NOTE:All Heat Transfer Multipliers Mom ACCA Manual"P'Sixth Edition for a medium outdoor daily range Use X 1.20 for no insulation 7 SIXTH ROAD P.O. BOX 2414 [PHAINC. WOBURN, MA 01888 FLUID INDUSTRIAL ASSOCIATES, INC. PHONE: 781-938-8900 • FAX: 781-933-3965 •TOLL FREE: 1-800-423-7187 WEBSITE: WWW.FIAINC.COM • EMAIL: CUSTSRV@FIAINC.COM nn�l3 /lG�kAt�G.y ^r i XZ W:NUG7ti� C. K� �G7 C��•!I�Ifr �D� ✓0 JLf a ' �u Cl` W,lvr)(?V„� l° Z" l`6T114� �V Xylem Bell & Gossett • Xylem McDonnell & Miller Xylem Domestic • Xylem Hoffman • Lochinvar• tekmar • Holby •Webstone Daikin • Flex-Hose • Preso • Laing • Envirosep • Kadant Johnson APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT T R vED 1540 SULLIVAN AVENUE I b � 644-251 I ext. 230 Bldg:Permit# ate Building Inspec "r Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 =3 / A)rz %Y& Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenar..t Designation Apt.No. APPLICANT APPLICANT ADDRESS S3 GL'�s�,.✓�.—ate �2J APPLICANT'S PHONE# 7`t'7a --C— t'�°s 73-7Ly3 OW N SF OWNER /�i 't OWNER ADDRESS Z 7 C/j ! OWNER PHONE C O ESTIMATED COST$ 3 Z a o •�i '` IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ L v � TYPE OF JOB: (e CP g `SOR•CO New Installation Alteration/Addition/Repair c2, 0 13 v i q-7 Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? li!"YES ❑ NO ❑ RESIDENTIAL CURRENT USE AND OCCUPANCY R�s .o�vr ❑ BUSINESS ❑ ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS / NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS _ NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS /-.3 NUMBER OF LIGHT FIXTURES /Z NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS , SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK L� !2&A C L� x �� r. l O�f,�. G�Z �a 2 .4 3 o c iz c Ae t. .I .J c /ram C).19 P. THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT J _ DATE rLr3 Zo/�/ DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is TOWN OF SOUTH WINDSOR 4) BUILDING DEPARTMENT APP 1540 SULLIVAN AVENUE Bldg. Permit# 644-2511 ext. 230 Date ilding Inspector Application must be printed or typed FEE SCHEDULE Location of,J"o�b: $0-$1,000=$15.00 FTenant Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT FEI--lN?— PWMIDWC, 4 Hl`f4"G LLC_ APPLICANT ADDRESS _38Y S LA tel2 S7 P-Etgll' ;5bu-tw wwOSoe- C-T 0eci7y APPLICANT PHONE# y3 ro -6 Ga y OWN SF OWNER ! 9C ".0��//� D�'1GI�rU OWNER ADDRESS � , So�tb� u8's . Cr D&o!j y OWNER PHONE d G d y�' �a3& O = ESTIMATED COST$ 4,2 G . IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ r � TYPE OF JOB: �� yy `s�R C _New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0 HEATING )d RESIDENTIAL ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_jgy__°F INSIDE effl _°F DIFFERENCE�_°F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) G664M40 CAA u o f s 3 A ;A F',.jrU^ A o SM itH OPv 14 4o I oo GROSS HEATING CAPACITY(INPUT—BTUH) POO NET RATING(OUTPUT—BTUH)__q_y. 6�0 TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑ INSIDE❑OUTSIDE CAPACITY X GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE _OF INSIDE -7L°F DIFFERENCE ZD °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE .L COOLING CAPACITY(BTUH) aZ 4D00 VENTILATION - DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) i! cx b M AAJ 13 Sri eo,,V,0p 1SeW + Ae o;L. TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 039 77 9 Z CONTRACTORS LICENSE NO. A TYPE Q STATE SIGNATURE OF APPLICANT .�k�Q�^ DATE 1 Proposal KELLNER PLUMBING & HEATING, LLC August 07, 2012 PO box 830 Reference#: 1599-103 South Windsor, CT 06074 Due Date: 8/22/2012 Office: 860-436-6824 Fax: 860-920-5215 www.kelinerplumbing.com dan@kelinerplumbing.com Job Name: Carolyn Monaco Carolyn Monaco 23-1 Arthur Drive 23-1 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-644-5236 860-644-5236 HerebyWe •mit Specifications And Estimates For: Remove and dispose of the existing warm air furnace and water heater(off site). Install a new 95% efficient Goodman GMH950 **313XA, two stage, warm air furnace with multi speed ECM blower motor, required ductwork and a concentric (single unit)vent on the exterior of the building. ** New furnace will be properly sized based on the existing furnace. Includes sidewall venting through the basement up to 50'. If roof venting is required an additional $150.00 will be charged. NO additional charges (extra's)will be incurred without prior approval by a board member and a written change order. Page 1 of 3 so Q^D �N �]�'� 40, 600 O o "V OO 1 ul ":w P114 .� :� .11 oto Proposal KELLNER PLUMBING & HEATING, LLC August 07, 2012 PO box 830 Reference#: 1599-103 South Windsor, CT 06074 Due Date: 8/22/2012 Ofce: 860-436-6824 Fax: 860-920-5215 www.kelinerplumbing.com dan@kelinerplumbing.com Job Name: Carolyn Monaco Carolyn Monaco 23-1 Arthur Drive 23-1 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-644-5236 860-644-5236 HerebyWe •mit Specifications And Estimates For: Existing air conditioning equipment to remain intact. Permanently cap flue in the basement. Does not include termination on roof/removal from attic. Installation includes: a new programmable energy saving thermostat, a new condensate pump, a new air filter and wiring with service switch and outlet. Install a 40 gallon natural gas direct vent water heater(non-sealed combustion). Replace furnace: Remove and dispose of the existing warm air furnace, humidifier. Existing A/C to remain intact. Install a Bryant BAV-042060 95%efficient furnace with variable speed (ECM) blower unit. Install exhaust and combustion air piping to the outdoors using PVC pipe. Connect to the existing A/C plenum and return duct with a new high efficiency filter unit. Remove and cap the existing chimney connection. Page 2 of 3 Proposal KELLNER PLUMBING & HEATING, LLC August 07, 2012 PO box 830 Reference#: 1599-103 South Windsor, CT 06074 Due Date: 8/22/2012 Office: 860-436-6824 Fax: 860-920-5215 www.kellnerplumbing.com dan@kellnerplumbing.com Job Name: Carolyn Monaco Carolyn Monaco 23-1 Arthur Drive 23-1 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-644-5236 860-644-5236 HerebyWe •mit Specifications And Estimates For. Drop clothes will be used to protect the floors in the home. All work to be completed in a professional manner. In the event that finished walls or ceilings have to be cut in order to run vent piping we are not responsible for repairing sheetrock. All equipment will be stored off site and all debris and equipment will be removed daily from the job site. NOTE: This quote does include tax as needed on a single, owner occupied unit. An additional $120.08 will be added to any rental/ income producing units for a new total sale price of $4444.04 1 have forwarded information on available rebates for high efficiency equipment. http://www.cf-p.com/Home/SaveEnergy/Rebates/Home_Services_And_Rebates/?Menul D=4294984962 Install Firomatic safety device on the ceiling as requested by fire marshal add $65.00 per unit. We propose hereby to furnish material and labor-complete in accordance with the above specifications,for the sum of: $ 4 TERMS: 50% Deposit& balance due upon completion. Please indicate acceptance of this proposal by signing below& returning with your deposit. All material is guaranteed to be as specified. All work to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon delays beyond our control. Purchaser agrees to pay all costs of collection, including attorney's fees. This proposal may be withdrawn by us if not accepted by the above due date. Authorized Acceptance Signature Signature Date _S7 7 i Proposal KELLNER PLUMBING & HEATING, LLC August 07, 2012 PO box 830 Reference#: 1599-102 South Windsor, CT 06074 Due Date: 8/22/2012 Office: 860-436-6824 Fax: 860-920-5215 www.kellnerplumbing.com dan@kellnerplumbing.com Job Name: Carolyn Monaco Carolyn Monaco 23-1 Arthur Drive 23-1 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-644-5236 860-644-5236 HerebyWe . Specifications • Estimates For: Optional upgrades: Add $400 to upgrade water heater to a QuietSide 92+% efficient wall hung tankless water heater with a 12 year warranty. Please initial here to select this option. Replace original Freon equipped air conditioning,components with new 13 SEER environmentally friendly R410A condenser, coil and refrigerant lines: add $1875.`Please initial hereto select,this option. R6qOe original Freon equipped air conditioning components with new 14 SEER environmentally friendly R410A nser, coil and refrigerant lines: add $2550. Please initial here to select this option. Re a original Freon equipped air conditioning components with new 16 SEER environmentally friendly R410A co ser, coil and refrigerant lines: add $3200. Please initial here to select this option. All work is warranted for a period of two years Page 1 of 2 � '� _ Ljtt( LET 1 � US r +rl�w , Proposal KELLNER PLUMBING & HEATING, LLC August 07, 2012 PO box 830 Reference#: 1599-102 South Windsor, CT 06074 Due Date: 8/22/2012 Office: 860-436-6824 Fax: 860-920-5215 www.kelinerplumbing.com dan@kelinerplumbing.com Job Name: Carolyn Monaco Carolyn Monaco 23-1 Arthur Drive 23-1 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-644-5236 860-644-5236 HerebyWe . Specifications • Estimates F• We propose hereby to furnish material and labor-complete in accordance with the above specifications,for the sum of: $0.00 TERMS: 50% Deposit& balance due upon completion. Please indicate acceptance of this proposal by signing below& returning with your deposit. All material is guaranteed to be as specified. All worts to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon delays beyond our control. Purchaser agrees to pay all costs of collection, including attorney's fees. This proposal may be withdrawn by us if not accepted by the above due date . Authorized #-� Acceptance Signature Signature > Date �� / DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 J 43 Date 64g nspector Application must be printed or typed FEE SCHEDULE Location of Job: a�t ibLfr Dc. $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 _ or any fraction thereof Tenant Designation Apt.No. APPLICANT Klii We?— PwM161VG d HF-"WC, , Ll_ e- _-- APPLICANT ADDRESS 38q S LA tE-r- 5'a0TFi W 1NOSoe— (? r Obej7q APPLICANT PHONE# � d' y3 to —( G? WN SF IC y OWNER ArrcIll' AYy z1� O q< OWNER ADDRESS a3-N A✓44 brjVC .o OWNER PHONE �(�U 7 C ESTIMATED COST$ (O 7 w. IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ lQ , 1� TYPE OF JOB: # 10 L �SOR'C0 _New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0 HEATING )4 RESIDENTIAL ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIIvnT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_,_°F INSIDE e_°F DIFFERENCE J?�O_F_°F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) G&'9d M4,0 Cs iuV 4S D #5 3 Q RA P,,,uA E A D SM Itfl OPOT 4p 100 d%yer-tt \r t.vr't (.m irze }.lam &- - 1 T-a.l✓,_cc9 GROSS HEATING CAPACITY(INPUT—BTUH)��Q NET RATING(OUTPUT—BTUH)_qj00 D TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION :❑ INSIDE❑OUTSIDE CAPACITY X GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE _OF INSIDE -71 OF DIFFERENCE ZD OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE .Z COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) J! aG b M AAJ 13 C'O/V DE0vSt g t A.0 0 1 TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 039 77 9 Z S-� C - CONTRACTORS LICENSE NO. TYPE 2STATE SIGNATURE OF APPLICANT DATE 3 3 Proposal KELLNER PLUMBING & HEATING, LLC May 23, 2013 Mailing Address: 389 Slater Street Reference#: 1694-101 South Windsor. CT 06074 Due Date: 6/7/2013 Office: 860-436-6824 Fax: 860-920-5215 www.kelinerplumbing.com dan@kellnerplumbing.com Job Name: Karen Warren Karen Warren 23-4 Arthur Drive 23-4 Arthur Drive South Windsor,CT 06074 South Windsor, CT 06074 860-670-2482 860-670-2482 HerebyWe .mit Specifications Remove and dispose of the existing warm air furnace and water heater(off site). VC, Install a new 95% efficient Goodman GMH950 ** 3BXA warm air furnace with required ductwork and a concentric (single unit) vent on the exterior of the building. ** New furnace will be properly sized based on the existing furnace. Includes sidewall venting through the basement up to 50'. If roof venting is required an additionaL$150_00 will be charged. NO additional charges (extra's)will be incurred without prior approval by a board member and a written change order. Existing air conditioning equipment to remain intact. Permanently cap flue in the basement. Does not include termination on roof/removal from attic. Installation includes: a new programmable energy saving thermostat a new condensate um a new air filter P 9 9Y 9 pump, and wiring with service switch and outlet. Install a 40 gallon natural gas direct vent water heater(non-sealed combustion). Page 1 of 5 Proposal KELLNER PLUMBING & HEATING, LLC May23, 2013 Mailing Address:389 Slater Street Reference#: 1694-101 South Windsor, CT 06074 Due Date: 6/7/2013 Office: 860-436-6824 Fax:860-920-6215 www.kelinerplumbing.com dan@kelinerplumbing.com Job Name: Karen Warren Karen Warren 23-4 Arthur Drive 23-4 Arthur Drive South Windsor,CT 06074 South Windsor,CT 06074 860-670-2482 860-670-2482 We Hereby Submit Specifications And Estimates For: OPTIONS: Upgrade to a Goodman GMVC95***3BX,variable speed,warm air furnace with required ductwork and a concentric(single unit)vent on the exterior of the building add$300.00. Initial here to select this option. Upgrade to a QuietSide 92%+efficient tankless water heater with 12 year warrantee add$460.00. Initial here to select this option. Replace the original Freon equipped air conditioning equipment with new 13 SEER R-410-A equipment add $1950. Initial here to select this option. Replace the original Freon equipped air conditioning equipment with new 14 SEER R-410-A equipment add $2630. Initial here to select this option. Replace the original Freon equipped air conditioning equipment with new 16 SEER R-410-A equipment add $3300. Initialhere to select this option. Install a new high efficiency air filter add$225.00 Initial here to select this option. Install a new wash-down high quality humidifier with humidistat add$420.00. InPakhere to select this option. Page 2 of 5 Proposal .:LLNER PLUMBING & HEATING, LLC May23,2013 sailing Address:389 Slater Street Reference#: 1694-101 South Windsor, CT 06074 Due Date: 6/7/2013 Office:860-436-6824 Fax:860-920-5215 www.kelinerplumbing.com dan@kellnerplumbing.com Job Name: Karen Warren Karen Warren 23-4 Arthur Drive 23-4 Arthur Drive South Windsor,CT 06074 South Windsor,CT 06074 860-670-2482 860-670-2482 SpecificationsWe Hereby Submit Drop clothes will be used to protect the floors in the home.All work to be completed in a professional manner. In the event that finished walls or ceilings have to be cut in order to run vent piping we are not responsible for repairing sheetrock. All equipment will be stored off site and all debris and equipment will be removed daily from the job site. NOTE:This quote is based on an owner occupied unit and does not include tax as needed on any rental/income producing units. IMPORTANT:We will help with applications for any possible rebates but have no control over the rebate programs and make no promises about what rebates are available,what qualifies for rebates or when the rebate programs may be terminated.. Page 3 of 5 Proposal KELLNER PLUMBING & HEATING, LLC May 23, 2013 Mailing Address: 389 Slater Street Reference#: 1694-101 South Windsor. CT 06074 Due Date: 6/7/2013 Office: 860-436-6824 Fax: 860-920-5215 www.kelinerplumbing.com dan@kellnerplumbing.com Job Name: Karen Warren Karen Warren 23-4 Arthur Drive 23-4 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-670-2482 860-670-2482 HerebyWe .mit Specifications And Estimates For: FURNACE AND WATER HEATER $4,525.00 FURNACE UPGRADE $300.00 FURNACE ONLY $3,064.00 WATER HEATER ONLY $1,460.00 V- TANKLESS UPGRADE $460.00 A/C 13 SEER $1,950.00 A/C 14 SEER $2,630.00 A/C 16 SEER $3,300.00 HUMIDIFIER $420.00 FILTER $225.00 TOTAL ' 7 ? 50% DEPOSIT CHECK CHECK NUMBER BALANCE DUE UPON COMPLETION35�•� J Page 4 of 5 Proposal KELLNER PLUMBING & HEATING, LLC May 23, 2013 Mailing Address: 389 Slater Street Reference#: 1694-101 South Windsor. CT 06074 Due Date: 6/7/2013 Office: 860-436-6824 Fax: 860-920-5215 www.kelinerplumbing.com dan@kellnerplumbing.com Job Name: Karen Warren Karen Warren 23-4 Arthur Drive 23-4 Arthur Drive South Windsor, CT 06074 South Windsor, CT 06074 860-670-2482 860-670-2482 HerebyWe . Specifications . Estimates For: NOTES: We propose hereby to furnish material and labor-complete in accordance with the above specifications, for the sum of: $4,525.00 TERMS: 50% Deposit& balance due upon completion. Please indicate acceptance of this proposal by signing below& returning with your deposit. All material is guaranteed to be as specified. All work to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon delays beyond our control. Purchaser agrees to pay all costs of collection,including attorney's fees. This proposal may be withdrawn by us if not accepted by the above due date Authorize ,� Acceptance ._�/ I 1 1 Signature 11 Signature Daft }J� DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: 1566 253 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 � 3 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: a;-a (If-mux or $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 _or any fraction thereof Tenant Designation Apt.No. APPLICANT K�-LW IZq PWMIDWG. d Ny%bWG , LL e- APPLICANT ADDRESS 5,007" W►NOSO4 , C'7 06cJ7y -- APPLICANT PHONE#'' II 96 d— 43 G -(o Ca y �0w N SFq OWNER )ean OWNER ADDRESS LE" E 11 i n a &k 0 p, OWNER PHONED"����()IDaO�S C a ESTIMATED COST$ L)LP U .� A*V IS THIS A CONTRACT COST? Yes _No �sv FEE ENCLOSED$ S j�bs O�� TYPE OF JOB: R C _New Installation Alteration/Addition/Repair -9613D 0-7 L+o Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0 HEATING A RESIDENTIAL ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_)gy__2F INSIDE g,0 _°F DIFFERENCE TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 66,84nAdU Cm if 4s D 453a$A F�rUA e A o SMitH OPON 4o I00 direct- veer �,,/.,r-��P }•� 191 7Q _ c. - ra,ttKlEss . GROSS HEATING CAPACITY(INPUT-BTUH) 44T0 NET RATING(OUTPUT-BTUH)� 06 0 TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION:❑ INSIDE❑OUTSIDE CAPACITY X GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE _OF INSIDE -71 -°F DIFFERENCE ZD °F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE 2- COOLING CAPACITY(BTUH) a2 q.60 D VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) eoiy ivs TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 039 7-7 9 Z CONTRACTORS LICENSE NO. TYPE / STATE SIGNATURE OF APPLICANT n 0 a, DATE lD I Proposal KELLNER PLUMBING & HEATING, LLC May 14, 2013 Mailing Address:389 Slater Street Summary: 3 South Windsor, CT 06074 Reference#: 1621-104 Office:860-436-6824 Fax:860-920-5215 Due Date: 5/29/2013 www.kelinerplumbing.com dan@kelinerplumbing.com Job Name: Jean-Marc Jacques Kesara Bhrugubanda 658 Ellington Road 23-2 Arthur Drive South Windsor,CT 06074 South Windsor,CT 06074 860-289-9105 860-282-0628 860-432-8164 We Hereby Submit Specifications And Estimates For: Remove and dispose of the existing warm air furnace and water heater(off site). Install a new 95%efficient Goodman GMH950**3BXA warm air furnace with required ductwork and a concentric (single unit)vent on the exterior of the building. **New furnace will be properly sized based on the existing furnace. Includes sidewall venting through the basement up to 50' If roof venting is required an additional$150.00 will be charged. NO additional charges(extra's)will be incurred without prior approval by a board member and a written change order. Existing air conditioning equipment to remain intact. Permanently cap flue in the basement. Does not include termination on roof/removal from attic. Installation includes: a new programmable energy saving thermostat, a new condensate pump, a new air filter and wiring with service switch and outlet. Install a 40 gallon natural gas direct vent water heater(non-sealed combustion). Page 1 of 5 Proposal KELLNER PLUMBING & HEATING, LLC May 14,2013 Mailing Address:389 Slater Street Summary. 3 South Krindsor, CT 06074 Reference#: 1621-104 Office:860-436-6824 Fax:860-920-5215 Due Date: 5/29/2013 www.kellnerplumbing.com dan@kellnerplumbing.com Job Name: Jean-Marc Jacques Kesara Bhrugubanda 658 Ellington Road 23-2 Arthur Drive South Windsor,CT 06074 South Windsor,CT 06074 860-289-9105 860-282-0628 860-432-8164 HerebyWe OPTIONS: Upgrade to a Goodman GMVC95'*'3BX,variable speed,warm air furnace with required ductwork and a concentric(single unit)vent on the exterior of the building add$300.00. Initial here to select this option. Upgrade to a QuietSide 92%+efficient tankless water heater with 12 year warrantee add$460.00. Initial here to select this option. Replace the original Freon equipped air conditioning equipment with new 13 SEER R-410-A equipment add $1950. Initial here to select this option. Replace the original Freon equipped air conditioning equipment with new 14 SEER R-410-A equipment add $2630. Initial here to select this option. Replace the original Freon equipped air conditioning equipment with new 16 SEER R-410-A equipment add $3300. Initial here to select this option. Install a new high efficiency air filter add$225.00 Initial here to select this option. Install a new wash-down high quality humidifier with humidistat add$420.00. Initial here to select this option. Page 2 of 5 Proposal KELLNER PLUMBING & HEATING, LLC May 14,2013 Mailing Address.389 Slater Street Summary. 3 South Windsor, CT 06074 Reference# 1621-104 Office: 860-436-6824 Fax: 860-920-5215 Due Date: 5/29/2013 www.kellnerplumbing.com dan@kellnerplumbing.com Job Name: Jean-Marc Jacques Kesara Bhrugubanda 658 Ellington Road 23-2 Arthur Drive South Windsor,CT 06074 South Windsor,CT 06074 860-289-9105 860-282-0628 860-432-8164 We Hereby Submit Specifications And Estimates For: Drop clothes will be used to protect the floors in the home.All work to be completed in a professional manner. In the event that finished walls or ceilings have to be cut in order to run vent piping we are not responsible for repairing sheetrock. All equipment will be stored off site and all debris and equipment will be removed daily from the job site. NOTE:This quote is based on an owner occupied unit and does not include tax as needed on any rental/income producing units. IMPORTANT:We will help with applications for any possible rebates but have no control over the rebate programs and make no promises about what rebates are available,what qualifies for rebates or when the rebate programs may be terminated.. Page 3 of 5 p Poposal May 14, 2013 KELLNER PLUMBING AT G, LLB PXaiflng Address'38.9 Sfater Street 11 # 1621- 04 1 _ South Windsor, C706()74 office: 860-430-024 Fax; 800-1 1 J321 512 313 www.kelinerplumbling-com n@ 1 nerplumbIng.rorn yea Marc Jacques Kesars 13hrugubanda 858 Ellington Road 23-2 Arthur Drive South Windsor, Cl-05074 South Windsor. CT 060:4 860-289-9105 860-282 � -01 L We H-rvb, 71113111it S[w(.-ifjcatiojis Atid EiAimates For: FURNACE AND WATER HEAT I 525.00 FURNACE UPGRADE 00.00 FURNACE ONLY 064.00 WATER HEATER ONLY 0.00 TANKLESS UPGRADE 0.00 A/C 13 SEER 450.00 i. A/C 14 SEER 330.00 A/C 16 SEER 1" 00-00 HUMIDIFIER r 42100 it FILTER 26.00 TOTAL 50% DEPOSIT CHECK NUMBER BALANCE IDUF- UPON COMPL ON Page 4 of 5 9 -cl XlJJ 13C83SU-1 dH WdL(3 :01 C102 C2 ReW P raposal May 14,2013 KELLNER PLUMBING _ G, LLC -- Ma111nq Address:388 Slater Street 3 1521. 104 South Windsor, CT 06074 ' Of ice. 860-436-6824 Fax:86011 i 2 ; MINN 5/29t. 013 www.kelinerplumbling,com 11 n I nerplumbing.com i Jea-Marc Jeo queb Kesara Bhrugubanda 65B Ellington Road i 23-2 Arthur Drive South Windsor,CT 06074 South Windsor,CT 05014 860-28"105 880-282-0 NOTES: e)t— bc We propose hereby to t'urniah mate I anlbor-oomplets In accordance with the above specifir«rtions,for the sum of: $4,625.00 TERMS: 50% Deposit& balance due upon cc h leti lease indicate acceptance of this proposal by signing bE. ow& returning with your deposit All material is guaranteed to be as specified I wo be completed In a professional manner according to standard practice Any alteration or deviation from above spedHcatlons involvim ra ' will be executed only upon written orders and will become an extra ohi ge over and above the estimate. Ah agreements contingent u clay and our control. Purchaser agrees to pay all costs of collection,Inclu.:ing attomeVe fees. This proposal may be withdrawn by us if no i p the above due date . Authoriz csptanoe �r Signaturdr"G W nature Date , S •d XUJ 13r83Sd1 dH WdLO r z i E 102 62 RRW APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT ( >o a 13 tP APP�ED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# Date Building Inspect r Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 FTe-nant iZ ' D,,)v — Over$1,000= Street Lot No. $15.00 per$1,000 �-,13�,�3—y,.Z 3--5 or any fraction thereof ignation Apt.No. APPLICANT Aeaz,t r APPLICANT ADDRESS ] APPLICANT'S PHONE# � 0* N $�. OWNER Ci 4- Wt- At � '9� OWNER ADDRESS 4)0 bl-HVAA p NO OWNER PHONE F`ti C 57 7 0Ak ESTIMATED COST$ C � `` IS THIS A CONTRACT COST? k Yes No FEE ENCLOSED$ /S TYPE OF JOB: Z�q �SOR•COS New Installation >,j Alteration/Addition/Repair DOI-�oo2�s Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES J2- NO l RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑ ASSEMBLY FUTURE USE AND OCCUPANCY 5 � ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK 06- i f'cTe-,'S /icS'i/��L /ll�' ✓ ;�NTcr rcr� /N j�ifLL ��Sc�C/uT //VS?"ife-L 11'10'T/0,rt/ 47- 1�0i7c",.z (>�c '�i�i?Zfi N✓i<< ��'iLI�1N r Si�ii(S � ��i'E.ii`GG- C.�itT�ti"� ���C�S '��itiOTc,� THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OFAPPLICANT � DATE �'//'i, APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT _ t APP OV 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# Date Building Inspector Application must be printed or typed FEE SCHEDULE //J� Location of Job: $0-$1,000=$15.00 313 Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT ,y 1l�e� ,{�� ,�',��L l 5_e_(v C2 APPLICANT ADDRESS &0�zr-L APPLICANT'S PHONE# OWNER G✓11 lSG 2e el- qOW N SF,q OWNER ADDRESS OWNER PHONE O ESTIMATED COST$ � >` C IS THIS A CONTRACT COST? Yes No FEE ENCLOSED $ TYPE OF JOB: cf ( $5 '"SOR,Co New Installation Alteration/Addition/Repair C7 ,� �� �� Revised 03/05/10 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OP SYSTEM: TYPE O BUILDING: HEATING RESIDENTIAL ❑ A/C COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW P SURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC V WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE - OF INSIDE 2r OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) )OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) v DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) c.✓ D GROSS HEATING CAPACITY(INPUT-BTUH) 7L'&- NET RATING(OUTPUT-BTUH) & lL TYPE OF FUEL ❑�,/.OIL-GPM OIL TANK LOCATION: El INSIDE ❑ OUTSIDE CAPACITY ; GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(B H) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLI G EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE OLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIP ENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRE AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICA ON) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Load Short Form Job: wrightsoft� Date: Nov 20,2012 Entire House By: Nutmeg Mechanical Services, Inc. 130-3 Utopia Road, Manchester,CT 06042 Phone:860-643-2042 Fax 860-643-1753 Email:chrisQnutmegmechanical.com Web:www nutmegmechanical com Project • • For: William Katzer 23/3 Arthur Drive South Windsor CT 06074 Phone: 860-644-1828 Design Information Htg Clg Infiltration Outside db(OF) -6 88 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD (OF) 76 13 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/lb) 52 26 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Trade ELITE 90 Trade Model EL296UH070XV36B-* Cond AHRI ref no.4988511 Coil AHRI ref no. Efficiency 96AFUE Efficiency 0 SEER Heating input 66000 Btuh Sensible cooling 0 Btuh Heating output 62000 Btuh Latent cooling 0 Btuh Temperature rise 77 OF Total cooling 0 Btuh Actual air flow 737 cfm Actual air flow 737 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) FIRST FLOOR 560 20901 7461 385 336 Room2 560 19156 8914 352 401 Entire House d 1120 40057 16375 737 737 Other equip loads 0 0 Equip. @ 0.93 RSM 15261 Latent cooling 2388 TOTALS 1120 40057 17650 737 737 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wrightSOW Right-Suite® Page Universal 2012 12.0.06 RSU12941 2012-Nov-20 09:age 1 1 ACClk Projecti.rup calc=MJ8 Front Door faces: N DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is TOWN OF SOUTH WINDSO I I I � I a ,2-060g3l BUILDING DEPARTMENT R VE 1540 SULLIVAN AVENUE 7 NIZ Bldg.Permit# /d, ,l� 644-2511 ext. 230 gouth Wlndsof Date Bu ding Inspector BUILDING DEPARTIAEN7 Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT KR . L.NV*- PWMBIV5. d HtIW,616 , Ll, e- -- APPLICANT ADDRESS 38 1 S LA ter- 5-1 0E-ET Zsbu-T Fi W w oso►e 0 6 ti 7 APPLICANT PHONE# d' ,q3 t*o r 6 tf,? OWN S41 OWNER JZ/q.--t r► OWNER ADDRESS So uv V7 �A�11V C107 F, OWNER PHONE —5V.V 7 O C a ESTIMATED COST$ -600 ► 0C) xw * IS THIS A CONTRACT COST? Yes _No FEE ENCLOSED$ 1?o r��sO O�� TYPE OF JOB: I2S C _New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 0 HEATING )4 RESIDENTIAL ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE__Agy_°F INSIDE_e O OF DIFFERENCE J?e °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 04 d c' A 4 c 3 6*4 ru ca4 E .1 Fj/zyr9- p' GROSS HEATING CAPACITY(INPUT—BTUH)-- "§o NET RATING(OUTPUT—BTUH) 6a D TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY X GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE -71 -OF DIFFERENCE 20 OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE 2- COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) GG'0btAflAJ J3 StZ¢ e0/V/J"wSeR f A,0.0 t. TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 03 9 7-7 q Zy- CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 10/12/12 FRI 09:45 FAX 8606445497 KING _ 0 001 ' r Proposal KELLNER PLUMBING &HEATING, LLC EATING A� PO box 830 gust 22,2012 South Wndsor, CT 06074 1470-106 s Office;860.436.6824. F=86"20,5Z1{ 4� Dafie�.? t` W612012 www.keilnerplumbing,com dan&elinerplumbing.com Kathlean and srum icng = .'.' 235 Arthur l)rtve Kathieert and in ce King South V18ndsor.CT 06074 23-5 Arthur owe South Windsor.CT 08074 8W644Z497 B6a726-8595 86G 644,A97 860-2264595 Remove and dispose of the existing wann air furnace and water heater(off site). Instal[a new 95°,6 efficient di-,V4 rT MR vim''R 6le S� motor,required ductwork and a concentric(single unit)Vent o Warm rbuwithl multi speed ECM blower '"New Mmsce wit be property sized based on the existing furnace. Includes sidewall venting through the basement up to 50'. If roof venting is required an additional$150.00 will be charged. NO additional changes(extras)will be incurred without prior approval by a board memberand a written change order. Permanently cap flue in the basement Does not Include termination on roof/removal from attie., Installation includes: anew Programmable energy Ong thermostat,anew conden to pump,a n �r�r and wiring with service switch and outlet 1 ----qeaL4hqcQ hi Drop clothes will be used t 5 s v t- P�ect the floors In the home.All work to be completed in a professional manner. In the event that finished watts or ceilings have to be cut in order to run vent piping we are not responsible for Page 1 of 2 < �10/42/12 FRI 09:45 FAIL 8806445497 RING 0 002 Proposal August2Z 2012 KELLNER PLUMBING &HEATING, LLC fJeference#::r 14-10-106 PO box 830 South Windsor, CT 06074 9I612012 Office:860.436-6824 I=860-920-5215 www.keitnerphunbing.com dan@kellnerplumbing.com Job:Name:.:::: Kathleen and Bruce King Kathleen and Bruce King 235 Arthur Drive 23-5 Arthur Drive South Windsor,CT 08074 South Windsor,CT 06074 860844-5497 860?284MQ5 860644-5497 860-2264M6 repairing sheeftwk All equipment well be stored off site and all debris and equipment will be removed daily from the job site. NOTE:This quote does Include tax as needed on a single,owner acoupied unit.An additional$120.08 will be added to any rentalf income producing units for a new total sale price of $4444.04 1 have forwarded information on available rebates for high efficiency equipment httplhvww cHxcomMome/SaveEnergy/RebatesMame_Smk =And Rebetes/7MenutD=4294984962 -lRs61NRnm We propose hereby to furnish material and labor-complete in accordance with the above speeWfflations,for the sum of: -$4A23-24- TERMS: 60%Deposit&balance due upon completion.Please Indicate acceptance of this proposal by signing below&retuming with your deposit All material is guarantead to be as specltied. An woikto be eompkied in professional manneracoarding to staaQasd pracUms. Any aeon or invohrio ends costs will be emoted only upon va ten orders and will become an extra charge over anti above deviation from above moan> ons 9 our Control. Purchaser agrees to Pay aII costs of aoneaio4 6idading a��g fees+ the estirrrate. M agreements contingent upon deldYs beyord This proposal may be v thdmwn by us 9 not accepted by the abawe due date. Authorised AecePUnce Signature Signature Dane N O O N O DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT � PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR t C BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE. Bldg.Permit# .644-2511 ext. 230 to Building fnspector Application must be printed or typed FEE SCHEDULE Location of Job: z q -' A�4 JA r- $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT "Y'/ ,,CLf�f APPLICANT�/// ADDRESS 6�y f.+�t �hP� `r/� /;'c/e , yti� 2 C—r d , APPLICANT PHONE# SOW N gFq OWNER Anti �Ol�%/, OWNER ADDRESS a' OWNERPHONE �7 C a ESTIMATED COST V '�• c IS THIS A CONTRACT COST? Yes No �G FEE ENCLOSED$ � TYPE OF JOB: New Installation z611n�a93 ,XAlteration/Addition/Repair n • v 0 V Revised 4/01//2002 � I 04/28/2009 TUE 11 10 FAX 19001/004 APPLICATION FOR HVAC PERWr(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: TING AziESIDENnAL ❑A/C ❑COMMERCIAL 0 VENTILATION ❑INDUSTRIAL .HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. O HYDRONIC WARM AIR ❑UNIT RADIANT DATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUU) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) ESCRME ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) lea GROSS HEATING CAPACITY(INPUT—BTUED NET RATING(OUTPUT—BTUH) TYPE OF FUEL 0 OIL--GPM- OIL TANK LOCATION:D INSIDEQ OUTSIDE- CAPACITY , GAS—INPUT I:PG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF. DIFFERENCE OF -TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) . FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK WkO'lw Lt ��f err e c�✓/ i /-� i�ti•, �✓i>f/- THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 030'31 �S -.S1 Sl CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 1 000,Ad App 1540 SULLIVAN AVENUE Bldg.Permit# �� T1 644-2511 ext. 230 (00(�?6 - aD to Building Inspect Application must be printed or typed Location of Job: FEE SCHEDULE '13 $0-$1,000=$15.00 Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS Z3 —25 RrIJA IL v2 APPLICANT'S PHONE# U 0t OWNER j4 r-4 P(f �yL- Ilk N SFq OWNER ADDRESS 4 If OWNER PHONE God * . ESTIMATED COST$ 25619' U IS THIS A CONTRACT COST? Yes No FEE ENCLOSED $ is ' TYPE OF JOB: . SO R•CO New Installation x Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑ RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑ ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK +�G S E LE C- M CA L- OuQ c Gas APP 2 o V Qz k6hv Ut 6 H�j THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 1 1 1 10 Electric# APPLICATION FOR BUILDING PERMIT Plumbing# 2301 Arthur Drive Date: 4 7 HVAC # �— Sprinkler# _ 73086 7- _ Estimated Cost $ 0 00 °4; FINAL APPROVALS _ Building COMPLETE RED BOXED AREAS Permit Fee $ Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit Eng. Insp. Fee $ A r. for CO. SIGN ON REVERSE SIDE Total Fee $� TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant M)CL&L-7�-,l jbjLJ\ Location of Work *V3 Hut s7R Lot No. Applicant's Address 31pa inc��sc cz_✓� k.- 14 _ tJ N rn &'�D.- Tel.# S(y a 3 4[, -Z)()gy Town M � ZipC1�� Lic.# Ownerk-kASAp,E ii rs Lia c]r->c)A414&k,, ,f itect Owner's Address AaTwua b2ru L_- Architect's Address Zip o--7y Zip- -Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit (20 ,N c. City Water❑ Well❑ Septic System❑ Sewer❑ Ins: HO SP Cert. ea Basement Garage Approved by Date Use Grou Construction Typ Revised 0/02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which thi guild g an is use is allowed. Signed I hereby apply for a Certificate of Occupancylor the ork escribed in this application for the permit. Signed /Lk DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# TOWN OF SOUTH WINDSOR Applica ' y: ' BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# LDate 644-2511 ext. 230 B i ing Inspector Application mast be printed or typed FEE SCHEDULE Location of Job: 23- 'Pc��v r nC $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 _ or any fraction thereof Tenant Designation Apt. No. APPLICANT APPLICANT ADDRESS t- S.vJ o - APPLICANT PHONE# O W N 's F,q OWNER OWNER ADDRESS OWNER PHONE C ESTIMATED COST$ xIS THIS A CONTRACT COS Yes _No o o FEE ENCLOSED$ ` y U 1�.3�� 1� TYPE OF JOB: �Sp R-C O� _New Installation �teration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF.SYSTEM: TYPE QF,BUILDING: 6HEATING RESIDENTIAL A/C I COMMERCIAL ❑ VENTILATION U INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC O WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL 0 OIL--GPM OIL TANK LOCATION :O INSIDE❑ OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK (1 �� `j \ \" �L ( THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT ��\�,��a A \�Z.��� DATE --I Z DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR `pp 0 0(6 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date BuildingNInspecto Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT De C, APPLICANT ADDRESS APPLICANT PHONE# �S— 0 W N S F OWNER -, �-�07. q� OWNER ADDRESS (�O) OWNER PHONE O E" a C ESTIMATED COST$ * IS THIS A CONTRACT COST? --Yes _No o �G FEE ENCLOSED$ 1� TYPE OF JOB: ljSOR.CON New Installation "AQeration/Addition/Repair APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A� fJ RESIDENTIAL BUILDING PERMIT APPLICATION? ❑YES C] O ❑BUSINESS CURRENT USE AND OCCUPANCY 0 ASSEMBLY 0 MERCANTILE FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑GARAGE ADDRESS 13 MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES ❑NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK C\L,A\LC-,rnc.S�C U 1 v J THE UNDERSIGNED HEREBY APPLILT FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS T7— COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 2 �5 `3,S C1 x Q_ \ CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Electric # 23-3 ArthQPPA'IMTION FOR BUILDING PERMIT Plumbing# HVAC# 11000639 Date: t 1 11/30� Sprinkler# Estimated Cost $$qgtq— FINAL APPROVALS Permit Fee $ 1 Building COMPLETE RED BOXED AREAS Occupancy Fee $_ Engineering TYPE OF PRINT ONLY Eng. Insp. Fee $ Affidavit =— Appr.forCO. ► SIGN ON REVERSE SIDE Total Fee $ f`� TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ b��L The undersigned hereby applies to do work according to the following: Applicant MGb11 ASSOCtrtfes LocationofWork 23-3 A - mr-oc LotNo. Applicant's Address 1137 Petrit Ftcs} a Tel # 401-447-7172 Town WDO()SoCk2+, Al Zip �_Lic.# 565522 owner Wil jiAM Ka ften 23-3 Architect Owner's Address VkW Amour Dr Architect's Address so- wirer, CC Zip 0607`f -Zip-- Sq. Ft. New Area: 1 st FI. 2nd Ff. 3rd Ff. Total New Area Purpose of this permit Mrisbnll NO re--pAacerneinrk ltncatjus City Water J Well J Septic System❑ Sewer❑ .74 J I y4 Ins: HO SP Cert. Area Basement Garage Approved by .a Date 64 •5F, - f i Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. Signe I hereby apply for a Certificate of Oc cy for theseribed in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS PERMIT CLOSED P 176 - AND - - _ CGS 29-393 Electric # APPLICATION FOR BUILDING PERMIT Plumbing# 2301 Arthur Drive HVAC# 14000023 Date: /09•30 - 00/3 Sprinkler# FINAL APPROVALS Estimated Cost $ 80001' Permit Fee $ 11;70_ Building COMPLETE RED BOXED AREAS Occupancy Fee $ /o— Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit Appr.for CO. SIGN ON REVERSE SIDE A 11 Total Fee $ 13" TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 7 The undersigned hereby applies to do work according to the following: Applicant PAO FEt3/0,01414 A00:4T ✓c s• Location of Work 03- / G[kT N _ Lot No. Applicant's Address 351 EVEQW Ei2`Ei2 '�+� • Tel # $bO-a0S-90O 7 Town (.SO uTH W/nl,0Sa/Z Zip _06 O7y _Lic.# DG_1 yya y Owner I&MAU) Bneja^1 Architect Owner's Address 493-/ AWAT14 U R_ Architect's Address Zip Zip Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit 6tiis14 APPAox 84 o Sb FT- OF ANVYarJr - NK FOA XSG /�S A BEyQOvM XEc RoOt,,f asE onlcr'. City Water❑ Well iJ Septic System ❑ Sewer❑ Ins: HO SP Area Basement Garage Approved by to Use Group Construction Type Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be I ted the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in w h is building its use is allowed. Signed I hereby apply for a Certificate of Occ n y for thkwr scribed in this application for the permit. Signed DO NOT CITE BELOW THIS LINE INSPECTION COMMENTS