Loading...
HomeMy WebLinkAbout200 CLINTON DR APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WENDSOR PEgMrT# Application is hereby: BUILDING DEPARTMENT . 1`7663(-Z AP RO 1540 SULLIVANA`TNUE 644-2511 ext. 230 Bldg.Permit# Date Building InCpectcd Application mast be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 F - APPLICANTuk i\, (N IR00A Over$1,000= Street Lot No. $15.00 per$1,000 or any fraction thereof signation Apt,No. �VYV1 SVM6 APPLICANT ADDRESS X '- l E I Ii(x�K, L� _ APPLICANT'S PHONE# p OWNER �A) Cw- Y`O.' iuc\ OWN SE4< OWNER ADDRESS ZCp CUB1Mn OOSA .ra t, C:V VOU��{ OWNER PHONE VD. 21'A ' 4 Z C * ESTIMATED COST$ 10.Cn5c-j.QC� IS THIS A CONTRACT COST? -Yea No FEE ENCLOSED$ 1(/6 TYPE OF JOB: 4' 2210 OR•CON New Installation J Alteration/Addition/Repair c-?,-.o1-7v10(� 2 Revised 03/05/10 APPLICATION FOR HVAC PERNM(Continued from ieverse side) TYPE 2F SYSTEM: TYPE OF BUILDING: HEATING 11 RESIDENTIAL ❑ A/C ❑ COMMERCIAL 61 VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT.HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE °F DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) � 'in,; z l+�1cyi 4 a rLui.1 P"ew-,can -Awr_1ard H1-1 41- �1 it l ���„w 5urn �-k"- '6 kl=r in 010,CS.. 4 +kl old Cnrner Qif Nw-id 6ir-I-tAjGrl-- Pic Hw-c a_v NIcdPl � i�+�1�►-10+31.�1--lal. GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ .INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STAVE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK CONTRACTORS LICENSE NO.,----::, O. E STATE SIGNATURE OF APPLICANT DATE �( —] r _ Load Short Form wrightsoft Date:e: Aug 19,2015 Entire House By: A.L Homestead Plumbing Heating Cooling and Energy 100 West Road,Ellington,CT 06029 Phone:860-870-8700 Fax 860-870-7731 Email:andrevA@homesteadtuel.com Web:horresteadmniortcom Project • • For. Robert and Kristine Hamilton 200 Clinton Drive, South Windsor, CT Design Information Htg Clg Infiltration Outside db(°F) 8 88 Method Simplified Inside db(OF) 72 75 Construction quality Semi-loose Design TD (°F) 64 13 Fireplaces 1 (Semi-loose) Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 28 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 66 ft Actual air flow 800 cfm High output baseboard 700 Btuh/ft Air flow factor 0.050 cfm/Btuh Total high baseboard 47 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 ROOM NAME Area Htg load Clg load Baseboard(ft) CIgAVF M (Btuh) (Btuh) Low High (cfm) Back Bed 195 7581 4064 15 11 202 Front Bed 195 7412 3597 15 11 178 Hall 50 2223 1286 4 3 64 Hall 2 25 275 96 1 0 5 Bath 1 80 2060 1211 4 3 60 M. Bath 120 3761 1444 8 5 72 Master Bed 240 8982 4131 18 13 205 Hall 30 498 142 1 1 7 Hall 1 40 440 153 1 1 8 Bok t#c vak w have been manua9y over>i°hlen Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2017-Jun-21 10:14 09 wrightsoft' Right-Suite®L)niversa12017 l7.023 FZSIJ22734 Page 1 ..rightsoltHVACWOM_SA_HAMILTON2NCFLRAHlr20151up C81c=MJ8 FrontDoorfacesSE Entire House 975 33232 16123 66 47 800 Other equip loads 0 0 Equip. @ 0.93 RSM 15059 Latent cooling 2820 TOTALS 975 33232 17879 66 47 800 Bokft!ic values have been manually overridden Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WI'1 htsOTi~' 2017-Jun-2110:14:09 ti 9 Right-Suite®Universal 201717.023 RSU22734 Page 2 / � _.rightsoltWACWOM SA_HAMILTON2NCFLRAHU2015.rup Calc=MJ8 Front Door faces:SE DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT 0N* -- APPRO D, 1540 SULLIVAN AVENUE 644-25 I 1 ext. 230 —Bldg. Permit# Date Building Inspector Application must be printed or typed FEE SCHEDULE ` Location of Job: E rlr1'tUY� ,z4$0-$1,000=$15,00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. G Q\'F IA APPLICANT ADDRESS 4-I ONO APPLICANT PHONE# t. g C �I N Sfq OWNER C e—f 54-1 (L�1 1 I o r < OWNER ADDRESS ,-SOU C f/`1 ✓4-CJ U) e OWNER PHONE r 7 7-- ESTIMATED COST$ Z .��► i * IS THIS A CONTRACT COST? ✓ Yes _No Qy. �(✓ FEE ENCLOSED$ ' •�'C� f��sO- .CO�� TYPE OF JOB: R _New Installation ✓?�,i -,� I _Alteration/Addition/Repair i APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF DING: WJIEATING URESIDENTIAL AIC ❑COMMERCIAL Cl VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. $HYDRONIC ❑ WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE AL HEATING EQUIPMENT f7 CL IN MAKE&MODEL NO.) J4� iCcu ti ic,1n -6 (' I Lc- roc��l-tom. c��f�� � e� 1 GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION:❑ INSIDE❑ OUTSIDE CAPACITY ❑G.AS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL C OLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) �C� iXIC cif. P 7,q 0 Z` Z-1 TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HE .APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO L L RDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE 9jM OF SUTH FORK. IfONfRA&MRS LICENSE NO. ` EV / STATE SIGNATURE OF APPLICANT I DATE f j� - i r Homestead Fuel, Inc. CT Lic. #'s S1-385604 100 West Road P1-278482 Ellington, CT 06029 SM1-006512 870-8700 Office 870-7731 Fax PROPOSAL Rob and Kristine Hamilton January 25,2013 Page 1 of 4 200 Clinton'Road Job Site:200 Clinton Road South Windsor,CT 06074 South Windsor,CT 06074 860-214-8429 kristinehamllton[ci)-att.net We hereby submit specifications and estimates for. New Hydro Air Heating and Cooling System and Indirect Hot Water Maker 1. The installation of a new American Standard Hydro-Air Heating and Cooling:., system for the first floor of the above home in place of"old Carrier Hydro Air system:..--p ; 2. The reclaiming and proper disposal of the old refrigerant R-22 charge in the old air conditioning system. I 3. The disconnection removal and disposal of the old air handler,air conditioning and condensate piping,indoor compressor unit,outdoor condenser section, humidifier system,all existing supply trunk lines and run-outs,an all existing return trunk lines and run-outs. !� 4. The existing supply register boots and grilles to remain in place at this time. ' 5. The existing return register boots and grilles to remain in place at this time. i 6. The installation of one new American Standard Variable Speed Air Handler with `cooling and heating coils In_ the basement in the same area as the existing air handler: Model#AAM7A024H21 7. The installation of an AutoFlo Humidifer In the ductwork of the above the air handler.Model#500A B. The.Installation of anew American Standard R-4101A 16 S.E.E.R 2 Ton Two Stage � "``1enset'on a pre-fab condenser pad in the same location as old condenser. Model#4A7A ovo000A r 9. The installation of all necessary boiler/air handler heat piping between the existing boiler piping to the new air handler. 10. The Installation of any necessary additional antifreeze in the heating system. 1 � 1 Proposal: Rob and Kristine Hamilton Page 2 of 4 11. The testing of the antifreeze level in the heating system to confirm proper freeze protection 12. The installation of all necessary air conditioning and condensate piping including condensate pump and components for the above cooling and humidifier systems. 13. The installation of pipe insulation on any new exposed heat piping at the air handler. 14. The installation of a new American Standand Programmable Two Stage Thermostat on the first floor of the home. Model#ACONT602. 15. The installation of the necessary new sheet metal R-8 Insulated supply and return ductwork trunk lines in the basement for the new system.The new trunk lines will be installed in the same general location as existing trunk line ductwork. 16. The installation of new R-8 insulated flexible return duct work run outs from the new trunk lines to the necessary existing supply and return grilles. 17. The installation of a manual balancing damper in each supply run-out. 18. All new ductwork and ductwork connections to be sealed with a mastic tape or sealer. 19. The Installation of the necessary high and low voltage electrical wiring connections from the existing condenser and air handler wiring circuits to the new condenser i and air handler units. 20. The installation of a new oil line from the oil tank to the existing oil bumer.This includes opening up a groove in the floor so that the oil line can be placed under the concrete slab and then cemented over. 21. The Installation of a Honeywell Supervent Air Eliminator in the existing boiler supply piping. I 22. The installation of a new Crown 40 Gallon Indirect Hot Water Maker which will ' supply the above home with domestic hot water in place of the old electric hot water heater and domestic tank-less hot water coil. Model#MS-40. i 23. The capping off of the old domestic tank less hot water coil hot and cold water lines and the removal of the old electric hot water maker. i 24. The installation of a new Grundfos IFC Circulator pump with isolation flange ball valves above and below the new circulator pump. • 25. The installation of the necessary ball valves in the indirect hot water maker boiler supply and return piping. 3 1 Proposal: Rob and Kristine Hamilton Page 3 of 4 26. The installation of the necessary ball valves in the Indirect hot water maker cold and hot water line piping 27. The installation of a new Honeywell Cold Start boiler control in place of the existing Honeywell Aquastat boiler controls. Model#L7224U. 28. The Installation of anew Taco Zone Valve Relay Control Panel with hot Water. priority.Model#ZVC404 29. All necessary pipe,fittings,material,and labor to complete the above installation. 30. All necessary permit and Inspection fees are included in this quote. 31. If Homestead Fuel, Inc.is awarded the contract for the above installation our Installation includes Five Years of Free Warranty Coverage on the Parts Supplied by the above Manufactures and the Material,Labor,and Workmanship supplied by Homestead Fuel Inc.to complete this installation. 32. This Warranty begins on the installation date and expires on the last day of the month following the anniversary date of the installation. 33. The above Warranty is transferrable for the remainder of the above terms to a new homeowner. 34. For the resolution of any Warranty Claims please contact our office at 860-870- 8700 and ask to speak with our service department. 35. The above Warranty doesn't include the necessary annual maintenance service for the above system. 36. Air Conditioning System SEER Rating=17.5 37. Air Conditioning System EER Rating=13.0 a i Proposal: Rob and Kristine Hamilton Page 4 of 4 $20,317.93 i Tax"-- `537.07' ' Total_$20,855.00 Town of South Windsor Permit Fee 330.00 Total $21,185.00 Sales Tax Exemption 72.80(Thermostat and Indirect Only) Total $21,112.20*Before Rebates/Tax Credits We propose hereby to furnish material and labor—complete in accordance with the above specifications,for the sum of:Twenty One Thousand One Hundred Twelve Dollars and 20/100($21,112.20). Payment Method: A Deposit of$8,600.00 and Balance upon Completion D Pt--. !ZS/i"/3 All material is guaranteed to be as specified. All work to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders,and will become an extra charge over and above the estimate. All ! agreements are contingent upon strikes,accidents,or delays beyond our control. Owner to carry fire, tomado,and other necessary insurance. Our workers are fugveredbyWorker'sCompensation Insurance. Authorized SignatureNote:Homestead Fuel,IndwW'ssal,,d not accepted within 30 days. Acceptance of Proposal-The above prices,specifications,and conditions,are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will by�e/made as outlined above. ' Signature_l� �i!�lc�..�� I Date of Acceptance__IIoZS�ao/�_ f i i YOU,the buyer,may cancel this transaction at any time prior to midnight of the third business day after the j date of this transaction. See the attached notice of cancellation for an explanation of this right. (Saturday is a legal business day in Connecticut.) This sale is subject to the provisions of the Home Soficitation Sales Act and the Home Improvement Act. The instrument is not negotiable. NOTICE OF CANCELLATION .You may cancel this transaction,without any penalty or obligation,within three business days from the above date. If you cancel,any property tr0ded in,any payments made by you under the contract or sale, the seller of your cancellation notice will return any negotiable instrument executed by you within ten busiress days following receipt.Any security interest arising out of the transaction will be canceled. If you cancel,you must make available to the seller,any goods delivered to you under this contract or sale, in substantially as good a condition as when received.You may,if you wish,comply with the instructions of the seller regarding the return shipment of the goods at the sellers expense and risk. ! If you do make the goods available to the seller and the seller does not pick them up within twenty days of the date of cancellation,you may retain or dispose of the goods without any further obligation. If you fall to ` make the goods available to the seller,or If you agree to return the goods to the seller and fall to do so,then ` you remain liable for performance of all obligations under the contract To cancel this transaction,mail or deliver a signed and dated copy of this cancellation notice or any other written notice,or send a telegram to HOMESTEAD FUEL,INC.,at 100 WEST ROAD,ELL.INGTON,CT 06029. Not later than midnight of hereby cancel this transaction (Buyer's Signature&Date) { f Right J®Mobile Report Date: 112 112 01 3 W Enure House By: Homestead Fuel Inc 100 West Road,Ellington,CT D6029 Phone:860.870-8700 Fax:860-870-7731 Email:andrewl@homesteadfuel.com License:S1-385604 Project • • For: Rob and Christine Hamilton 200 Clinton Drive,South Windsor,CT 06074 Phone:860-214-8429 Email:kristinehamilton@aft.net Design Conditions Location: Indoor: Heating Cooling Hartford Brainard Fd,CT,US Indoor temperature(T) 70 75 Elevation: 20 ft Design TD(T) 59 13 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 25.1 32.1 Dry bulb(T) 11 88 Infiltration: Dailyrange(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 73 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 2(Average) Heating Component Btu h/f 2 Btuh %of load Walls 4.8 5123 16.3 va Glazing 33.0 7124 22.7 Doors 23.2 730 2.3 �Iy , Ceilings 0 0 0 Floors 6.6 8452 26.9 Gad Infiltration 6.3 8246 26.2 Ducts 1756 5.6 Piping 0 0 Humidification 0 0 l7aQs Flans Ventilation 0 0 Adjustments 0 Total 31431 100.0 Component Btuh/ft2 Btuh %of load Walls 1.5 1583 10.8 vwis IrtelM G1rs Glazing 34.1 7361 50.3 Doors 9.9 311 2.1 Ducts Ceilings 0 0 0 Floors 1.4 1821 12.5 1 Irfiltratian Infiltration 0.6 723 4.9 Ducts 708 4.8 Ventilation 0 0 Fk1os Internal gains 2120 14.5 Blower 0 0 Gaarg Doors Adjustments 0 Total 14627 100.0 Latent Cooling Load=2252 Btuh Overall U-value=0.154 Btuh/ft2-°F Data entries checked. ..�.•.�0 2013Jan-Jan 13:59:31 W ■iO Right-Sulte0 Universal 2012 12.1.05 Right JO M°bile Page 1 Ak C:\WINDOWS\TEMPlwstmplcfabea77-42ca4eet-aW-2b3bUtN4c5.rup Calc=MJ8 Front Door faoss: N J Summary Pro ect Job: -P� wr�ghtsoft. 1 •J Date: 1/2112 01 3 Entire House By: Homestead Fuel Inc 100 West Road,Ellington,CT 06029 Phone:860-870-8700 Fax:860.870-7731 Email:andreM@homesteadfuel.com License:S1-385604 Project • • For: Rob and Christine Hamilton 200 Clinton Drive,South Windsor,CT 06074 Phone:860-214-8429 Email:kdstinehamilton@att.net Notes: Design Information Weather: Hartford Brainard Fd, CT,US Winter Design Conditions Summer Design Conditions Outside db 11 °F Outside db 88 °F Inside db 70 °F Inside db 75 °F Design TD 59 °F Design TD 13 'F Daily range M Relative humidity 50 % Moisture difference 32 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29675 Btuh Structure 13919 Btuh Ducts 1756 Btuh Ducts 708 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31431 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 14627 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 2(Average) Structure 1921 Btuh Ducts 331 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftz) 1284 1284 Equipment latent load 2252 Btuh Volume(ft') 10272 10272 Air changes/hour 0.74 0.30 Equipment total load 16879 Btuh Equiv.AVF(cfm) 126 51 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 0 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 "F Total cooling 0 Btuh Actual air flow 686 cfm Actual air flow 686 cfm Air flow factor 0.022 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ` Wr heft, 2013-Jan-2113:59:31 RightSufte®Universal 2012 12.1.05 Right A Mobile page 1 C:IWINDOWSITEMPIwstmpkiabea7742ca-4ea6-364f-2b3b3dc984c5.rup Calc-MJ8 Front Door faces: N -t#t-wrightsaftt Right-32)Worksheet Job: Entire House Date: 1/2112013 Homestead Fuel Inc By: 100 West Road,Ellington,CT 06029 Phone:860-870-8700 Fax:860-870-7731 Email:andrewl@homesteadh,el.com License:Sl-385604 1 Room name Entire House First Floor 2 Exposed wall 164.0 ft 164.0 ft 3 Room height 8.0 ft d 8.0 ft heattcool 4 Room dimensions 1.0 x 1284.0 ft 5 Room area 1284.0 ft' 1284.0 fl' T Construction U-value Or HTM Area ft' Load Area ft' Load Y number (St uh/ft�-F) (Btuh/ft2 I or perimeter (it) I (Btuh) or perimeter (ft) I (Btuh) I Heat Cool Gross N/P/S H I Cool j Gross I NIP/S j Heat cod 6 W 12C-2sw 0.081 n 4.81 1.49 384 314 1511 467 364 314 1511 467 �G 1Dc2ov 0.570 n 33.86 18.02 70 0 2370 1261 70 0 2370 1261 V12C-2sw 0.081 a 4.81 1.49 272 194 933 288 272 194 933 288 1D-c2ov 0.570 a 33.86 59.92 47 0 1580 2796 47 0 1580 2796 11 (---D 11 D0 0.390 a 23.17 9.89 32 32 730 311 32 32 730 311 12C-2sw 0.081 s 4.81 1.49 384 300 1443 446 384 300 1443 446 1 Dc2ov 0.570 s 33.86 31.39 12 0 406 377 12 0 406 377 ID-c2owd 0.570 s 33.86 31.39 42 0 1422 1318 42 0 1422 1318 4A3-2ov 0.470 s 27.92 23.66 30 0 838 710 30 0 838 710 Vll 12C-2sw 0.081 w 4.a1 1.49 272 257 1237 382 272 257 1237 382 �---G ID-c2ov 0.570 w 33.86 59.92 15 0 508 899 15 0 508 899 C Cent 0.000 - 0.00 0.00 1284 1294 0 0 1284 1284 0 0 F 19A-Obvcp 0.295 - 6.58 1.42 1284 1284 8452 1821 1284 1284 8452 1821 61 c)AED excursion 0 0 Envelope loss/gain 1 214291 110761 1 1 214291 11076 12 a) Infiltration 8246 723 8246 723 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 23D 4 920 4 920 Applianceslother 1200 1200 Subtotal(lines 6 to 13) 29675 13919 29675 13919 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 29675 13919 29675 13919 15 Dud loads 6% 5% 1756 708 6% 5% 1756 708 Total room load Air required(cfm) } 3164386I 14627 686I 37431 686 I 14627 686 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t 414- wri9htsoft' 2013Jan-21 13:59:31 Right-Suite®Universal 2012 12.1.05 Right J®Mobile Page 1 C:IWINDOWSITEMPIwsUMNcbbea77-42c&4eab-ad4f-2b3b3dc984c5.rup Call:-MJ8 Front Door faces: N Component Constructions Job: WrlghtSQft Date: 112112013 Entire House By: Homestead Fuel Inc 100 West Road,Ellington,CT 06029 Phone:860-870-8700 Fax:860-870-7731 Email:andrewl@homesteadfuel.com License:S1.385604 Project • • For: Rob and Christine Hamilton 200 Clinton Drive,South Windsor,CT 06074 Phone:860-214-8429 Email: kristinehamilton@aft.net Design C• • • Location: Indoor: Heating Cooling Hartford Brainard Fd,CT,US Indoor temperature(T) 70 75 Elevation: 20 ft Design TD(T) 59 13 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 25.1 32.1 Dry bulb(T) 11 88 Infiltration: Dailyrange(TF) - 18 ( M ) Method Simplified Wet bulb("F) - 73 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 2(Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain tF Bbli/te-'F IF-'FBtuh B%MIIF Btuh BIuMF Stuh Walls 12C-2sw:Frm wall,vnl ext,r-13 cav ins,1/2"gypsum board int n 314 0.081 15.0 4.81 1511 1.49 467 fish,r-2 ext bd ins,2"x4"wood frm a 194 0.081 15.0 4.81 933 1.49 288 s 300 0.081 15.0 4.81 1443 1.49 446 w 257 0.081 15.0 4.81 1237 1.49 382 all 1065 0.081 15.0 4.81 5123 1.49 1583 Partitions (none) Windows 1 D-c2ov:2 glazing,cir outr,air gas,vnl frm mat,dr innr,1/4"gap, n 70 0.570 0 33.9 2370 18.0 1261 1/8"thk a 47 0.570 0 33.9 1580 59.9 2796 s 12 0.570 0 33.9 406 31.4 377 w 15 0.570 0 33.9 508 59.9 899 all 144 0.570 0 33.9 4864 37.1 5333 1 D-c2owd:2 glazing,cir outr,air gas,wd frm mat,clr innr,1/4"gap, s 42 0.570 0 33.9 1422 31.4 1318 1/8"thk 4A3-2ov:2 glazing,clr low-e outr,air gas,vnl fnn mat,clr innr,1/4" s 30 0.470 0 27.9 838 23.7 710 gap,1/8"thk Doors 11 DO:Door,wd sc type a 32 0.390 0 23.2 730 9.89 311 Ceilings Ceil1:Ceil1 1284 0 0 0 0 0 0 Floors 19A-0bvcp:Flr floor,wd fir,1"thkns,carpet fir fish,leaky bsmt ovr 1284 0.295 0 6.58 8452 1.42 1821 .� W 111t,40R 2013-Jan-2113:59:31 Right-Suite®Universal 2012 12.1.05 Right J®Mobile Page 1 C:\WINDOWSITEMRwstrnplcfabea77-42ca4eab-ad4f-2b3b3dc984c5.rup Cale=MA Front Door faces: N AED Assessment Job: - wrightsoft Date: 1/21/2013 Entire House By: Homestead Fuel Inc 100 West Road,Ellington,CT 06029 Phone:860-870-8700 Fax:860-870-7731 Email:andrewl@homesteadfuel.com License:S1-385604 Project • • For: Rob and Christine Hamilton 200 Clinton Drive,South Windsor,CT 06074 Phone:860-214-8429 Email:kdstinehamilton@att.net Design Conditions Location: Indoor: Heating Cooling Hartford Brainard Fd, CT,US Indoor temperature(°F) 70 75 Elevation: 20 ft Design TD(°F) 59 13 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gNlb) 25.1 32.1 Dry bulb(°F) 11 88 Infiltration: Dailyrange(°F) - 18 ( M ) Wetbulb(°F) - 73 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Hourly Glazing Load 1Z000-- 11, 000-- 10,000-- m 9, 8, 0 7,000- co 6, 5, 4, 3, z 1, 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / HoWy / Aerage i P®limit Maximum hourly glazing load exceeds average by 22.5%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh �y. w htsoft' 2013-Jan-2113:59:31 •r' RightSuite®Universal 2012 12.1.05 Right J®kbbile Pape 1 Gff1 C:\WINDOWS\TEMP\wstmp\cfabea77-42ca-4eab-ad4f-2b3b3dc984c5.rup Calc=W8 Front Door faces: N N First Floor First Floor Job#: Homestead Fuel Inc Scale: 1 :80 Performed for: Rob and Christine Hamilton Page 1 100 West Road RightSuite®Universal 2012 200 Clinton Drive Ellington,CT 06029 12.1.05 Right J®Mobile South Windsor,CT 06074 Phone:860-870-8700 Fax:860-870-7731 2013-Jan-21 13:59:32 Phone:860-214-8429 andrewl@homesteadfuel.com •••-42ca-4eab-ad4f-2b3b3dc984c5.rup kristinehami Iton @att.ne Ell,ccric # APPLICATION FOR BUILDING PERMIT Plumbing# 200 Clinton Drive Date: _ HVAC # - - Sprinkler# 31033 Estimated Cost $� FINAL P Buildin 1 s3 ,. .�.� -- - - - - -- - - _-I Permit Fee $ En ne� ' COMPLETE RED BOXED AREAS Occupancy Fee $ Af davi TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr. for CO. SIGN ON REVERSE SIDE -- Total Fee $ TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant ea, Location of Work .2>0 C Lot No. Applicant's Address Tel.# <125r- yr, `o Town Zip ,a/( 1?' Lic.# 9!fy Owner io Architect Owner's Address GCS C 6:�z .D/ Architect's Address 5716VIAa cc - G7 Zip e&_)`_7G/ Zip Sq. Ft. New Area: 1st FI. 2nd Ff. 3rd FI. Total New Area Purpose of this permit r�ar�' / f' �- jlr' / P a / e & �..� AeT City Watero Well❑ Septic Systemo Sewero Ins: HO At a Basement Garage Approved by '° ate Use Grou Construction Type_ Revl"d 6102 J 46 1 hereby agree to conform to all the requirements of the Laws of the Staty of Connecticut and the O finances of the Town of South Windsor and to notify the Building Inspector of any alteration i ns or speyificati of the Building for which this permit is asked,and agree that this building is to be boated the dista It fines,side yard lines,and required distances from all other zones and is located in which this bui Signed I hereby apply for a Certific;e-d of�u�nncy for the worts described in this lication for the permit Si DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS i Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-31033-B 9,548 810 FINAL O1/20/05 JFF A B10 FINAL O1/20/05 JFF A CLOSEOUT JOSEPH R. N/F ANTHONY DZEN N/F WILLIAM R. SMITH BELL ET AL `To ' 3Zo i /� , �� ► N/ F SET 235.00' MILDRED B. SMITH '4S° 100.00 I.P / / ° _/ / 13500 1.P 330 C LOT I m►o `cb4 cu / co 4pA E,� ti?, / --I P 1780 -32'- 15° ,` f /cv 4°��9 / 60 / TO SET — / �� // / / �400y ES 2 LO T *lk 2 I AREA = 2.42 ACRES + 93 Nt O CY �° / _ I.P I TO, i\ tt i 612 .95 ao. -+S 4I° i r \ \ \ \\ \ \ 1 O LOT # 14 LOT # 28 / TEMP ► z ' 33 CUL DE-SAC) 0 C z AP REFERENCE N / F DOE EING LOT 2 ON MAP OAK RIDGE ESTATES INC. PAV'T• NTITLED SUBDIVISION PLAN Ex�sT OR MILDRED B. SMITH M.H. CALE 1°= 40' DATE 5-30-79 \�����`�QF"1�t rNt'•,,•,� �tNtm mom._ r � EMIL W. LUCEK ASSOCIATES ��,�`���F, E� M Cl/eir-"' IL APPLICANT NAME. THOMAS G. 9 CAROL DENNIS DDRESS. 309 ELLINGTON ROAD 4 SOUTH WINDSOR , CONN, 06074 ��ys mW a��a o Sfl<RVE�� PHONE 203- 289 - 4104 OR BUILDING PURPOSES ZONE RR PROPERTY OF THOMAS G. a CAROL H. DENNIS 200 CLINTON DRIVE SOUTH WINDSOR, CONN. EMIL W . LUCEK ASSOCIATES NO. REVISIONS DATE SCALE I'= 40' DATE 6- 6-79 CONSULTING ENGINEERS 5 OAKLAND ROAD SOUTH WINDSOR, CONN. DRAWN A.V H. CHECKED E.W.L. 203.644.2474 PROJECT 79 -91 SHEET [CERTIFIED SUBSTANTIALLY CORRECT - DEGREE OF ACCU"Cff - A- 2 APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 15,00'3"i 4 PROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 OU C ln-t n n R 6 Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT _ HDM CS j f0 d APPLICANT ADDRESS Rd u -'� P.0 gl� C-F APPLICANT'S PHONE# �('j - F52 0 Z� OWN 3F OWNER Rb� S ris71Oe. HL�mi l fiGn q q< OWNER ADDRESS QC)[-) C 11 r1+n r) Rd SC)Uk-M IJY Ind SCEr Cr OUC-hl OWNER PHONE (Zt D6 I O ESTIMATED COST$ R Q ,.� = U IS THIS A CONTRACT COST? Yes No G&'A FEE ENCLOSED$ �! o TYPE OF JOB: � ( S I S� - �U � C ��I 15- OR•C0 \/ New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR HVAC PERNUT(Continued from reverse side) TYPE 7 SYSTEM: TYPE OF UILDING: HEATING 51RESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 21C.1 l D (?1'! fi r►n'CL vA G-11G�{ p201 Ifr N(GdCl it 6FtP—( #Lfc4Lf3a35 GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. RTfr-63gI (o;o-s CT CONTRACTORS LICENSE NO. TYP STATE g SIGNATURE OF APPLICANT DATE I � I Is —T I N/ F JOSEPH R. I N/F ANTHONY DZEN I N/F WILLIAM R. SMITH BELL I ET AL To ' 320 / f /, N / F SET 235'00' i I.P./ / �� N44o _/ MILDRED B SMITH -9 100.00 / 135.00 / I P 330 Js�. // i // /� // a LOT I CoIp OOd /� / / cv r6 / c0 NN ---- P 178° -32 - 15" / / N /F TO l Q � / �� '�� � � cis•. ' / OAK SET RIDGE ESTATES, / / ► `' / ! I � / LOT # 42 / / LOT #k 2 AREA = /2.42 ACRES / I.P Y� N` �hif0 pi'° / M o W O < O C., OL0 OI N I.P. L _ I P i /a ti�w►C TO �ET 0� ! 27. 5' - - 3zo.1 , ET �e I 1 612 .95 -«S 410 - 33 - 30 W ,- so oQ' LOT ## 14 LOT # 28 `�" / TEMP I -i 3_�O CUL DE-SAC-1 O Z N / F EDGE MAP REFERENCE PAV'T. OAK RIDGE ESTATES INC. � BEING LOT 2 ON MAP �X�sT ENTITLED 11 SUBDIVISION PLAN M.H. FOR MILDRED B SMITH i19 annnikaidn � SCALE I"= 40' DATE 5-30-75 •�����pF CUi�lyfC'�►y ��� ,��m,. � .v EMIL W LUCEK ASSOCIATES y `'J�1. M l���G�, ���� t - '. J ` P tell I tI APPLICANT �' 43i-,' sic, o� Na 93 Q.r No.6293 NAME; THOMAS G ® CAROL DENNIS $����F ADDRESS'. 309 ELLINGTON ROAD SURVEv� � SOUTH WINDSOR , CONN 06074 PHONE 203- 289 - 4104 FOR BUILDING PURPOSES ZONE RR PROPERTY OF THOMAS G. 81 CAROL H. DENNIS 200 CLINTON DRIVE SOUTH WINDSOR, CONN. EMIL W . LUCEK ASSOCIATES NO. REVISIONS DATE SCALE I'= 40' DATE 6- 6 -79 CONSULTING ENGINEERS 5 OAKLAND ROAD DRAWN A.V H, CHECKED E W L SOUTH WINDSOR. CONN. 203-644.2474 PROJECT 79 -91 SHEET CERTIFIED SUBSTANTIALLY CORRECT DEGREE OF ACCUF}ACY A - 2 WIN+DSOR DATE: lam¢•-7g► SIQ.t A4-S - 8 Avlo"hv gy Z GD N /F WILLIAM R. SMITH N/ F JOSEPH R. I N/F ANTHONY DZEN I I BELL � I p I 3z 0 � I ET AL To / � ' f� MILDRED B. SMITH SET 235�00' / I.P� N 44° - I ' 1.P 330 9 100.00 / 135.00 _ LOT I O Co10 004 ?6° l tT N qcF< -- 10 178° -32'� 15� N /F To OAK SET RIDGE ESTATES// / t LOT #� 2 LOT # 42 / AREA = 2.42 ACRES I p r i • � N I � a i W / / O N O / o N <� ' p Fo / A 61 I / L `nlo SGRgFCF� ,d- / OF co ` C I.P °�a / 50. �O .-S 441° - 33 - 30 W ISET oa 612 .95 z I 330 20 TEMP. 3 I LOT # 28 CUL DE-SAC.I LOT # 14 Z EDGE N / F PAV'T. MAP REFERENCE OAK RIDGE ESTATES INC. — Ex�sT MIA. BEING LOT 2 ON MAP 3%9. pl SUBDIVISION PLAN ENTITLED glnnr,�n `\\`\`���Y�nG N1 iiiii"' FOR MILDRED B. SMITH '���iii DATE -30'79 SCALE I'•= 40' 5 �P EMIL W. LUCEK ASSOCIATES No.6293 APPLICANT > Ai �,,n , NAME: THOMAS G. a CAROL DENNIS vi�q��uluuuN,I�,�u�� �uuauuuuu���o ADDRESS, 309 ELLINGTON ROAD SOUTH WINDSOR , CONN 06074 PHONE 203- 289 - 4104 ZONE RR FOR BUILDING PURPOSES CAROL H. DENNIS PROPERTY OF THOMAS G. 8` SOUTH WINDSOR, CONN. 200 CLINTON DRIVE EM1L W . LUCEK ASSOCIATE N0. REVISIONS DATE, SCALE I'= 40' DATE 6- 6-79 �S j7 (�L-��•t�� � V I AS BUILT 9-28-79 _._. - CONSULTING ENGINEERS DRAWN A.V.H. CHECKED E.W.L. 5 OAKLAND ROAD SOUTH WINDSOR, CONN. PROJECT 79 203-644-2474 RACY- DEGREE OF ACCU - A- 2 �/5�'��� • CERTIFIED SUBSTANTIALLY CORRECT l 1300064 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 02/06/2013 GIS ID:21300200 FEE: 330.00 MUNIS APPLICATION# 201300116 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: HOMESTEAD FUEL INC ADDRESS: 200 CLINTON DRIVE ADDRESS: PO BOX 749 �',. OWNER: HAMILTON ROBERT B&KRISTINE M ELLINGTON,CT 06029' - 200 CLINTON DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: INSTALL HEATING AND COOLING SYSTEMS. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION'AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 2/6/2013 11:44 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1500394 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 09/24/2015 GIS ID:21300200 FEE: 135.00 MUNIS APPLICATION# 201501224 BUILDING DESCRIPTION: APPLICANT . LOCATION NAME: HOMESTEAD FUEL INC ADDRESS: 200 CLINTON DRIVE ADDRESS: PO BOX 749 t' OWNER: HAMILTON ROBERT B&KRISTINE M ELLINGTON,CT 06029'; 200 CLINTON DRIVE South Windsor,CT 06074 DESCRIPTION OF WORK: INSTALL`BOILER. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 9/24/2015 3:24 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1700362 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 08/14/2017 GIS ID:21300200 FEE: 165.00 MUNIS APPLICATION# 201701062 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: HOMESTEAD FUEL INC ADDRESS: 200 CLINTON DRIVE ADDRESS: PO BOX 749 OWNER: HAMILTON ROBERT B&KRISTINE M ELLINGTON,CT 06029 200,CLINTON DRIVE South Windsor,CT 06074 DESCRIPTION OF WORK: INSTALLATION OF A HYDRO-AIR HEATING SYSTEM FORE THE 2ND FLOOR IN PLACE OF THE OLD AIR HANDLER SYSTEMS AND DUCTOWORK. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 8/14/2017 2:43 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE