Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20 LEXIE LN BDLG 23
-.13 Electric # APPLICATION FOR BUILDING PERMIT Plumbing# HVAC# �� -� �- j'`e Date: _ (� Sprinkler# �P 00-7 1Z Estimated Cost $ FINAL APPROVALS Building COMPLETE RED BOXED AREAS Permit Fee $ IG9 r, Engineering Occupancy Fee Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr.forCO. SIGN ON REVERSE SIDE t � Total Fee $ i TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 4 �2Sf`12 The undersigned hereby applies to do work according to the following: Applicant f rima(liaLocation of Work _ CX�G tie, Lot No. 13 Applicant's Address I I Tel # W 6- U0- ql Town V 1 C7K CT Zip U Lic.# 60 Owner Architect l QC nj &S* Owner's Address Architect's Address l 5b f r UV Zip 9 S' Zip Sq. Ft. New Area: 1 st FI. 2nd Fl. JW 3rd/FI. 3 9/2 Total New, 1�33 Purpose of this permit co rug �/ 644� U{ Inr Q QIt4 L G iwd lic City Water Well J Septic System J Sewer LIB �Zi6f Olylf Ins: HO Cert, Area Basement Garage Approved by Date Use Group �' Construction Type �— Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of , South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper dis nce from all street lines,side yard lines,and required distances from all other zones and is locate/whicl,, his uildin t se is allowed. Signed I hereby apply for a Certificate of Occuppfcy for the w d cribed in this application for the permit. Signed DO NOT WRITE BEZOW7THIS LINE INSPECTION COMMENTS f INSPECTION FIELD SHEET 02/18/21 Printed by Middleton, Morgan 08 37 58 INSPECTION: 89701 FOOTING PERMIT: STATUS APPLICATION: 201601418 LOC: 20 LEXIE LANE SOUTH WINDSOR PROPERTY ID: 53450020 OWNER: T & M BUILDING CO INC CONTRACTOR: REQUEST BY: PROJ DESC: CONSTRUCT SINGLE FAMILY TOWN HOUSE WITH 2 BEDROOMS, 2 1/2 WORK ORDER: INSPECTOR: ROSE RESULT: PASS REQUESTED: 06/02/17 PRIORITY: SCHEDULED: 06/05/17 AM COMPLETED: 06/05/17 UNPAID FEES 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS: ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION B002 FOUNDATION 10/12/17 ROSE PASS B003 FRAMING (ROUGH) 10/16/17 ROSE PASS B004 INSULATION FIRESTOPPING & INSULATION B005 FIREPLACE / CHIMNEY 07/12/18 ROSE PASS BO10 FINAL CONDENSATE TO DISCHARGE WITH AIR GAP SUBMIT TECHNO POST REPORT. 07/18/18 ROSE PASS BO10 FINAL 09/28/17 ROSE PASS E001 ELECTRIC SERVICE OK TO RELEASE TO EVERSOURCE 07/05/17 DOUG PASS E002 ELECTRIC UNDERGROUND 10/12/17 ROSE PASS E003 ELECTRIC ROUGH 10/12/17 ROSE PASS H003 HVAC ROUGH DUCTWK & CONTROL WIRING 07/05/17 DOUG PASS P002 PLUMBING UNDERGROUND 09/15/17 ROSE PASS P003 PLUMBING ROUGH PRESS. TEST ON DWV & WATER PIPES./ CONTR. TO INSTALL ACCESS PANEL TO CLEANOUT IN ENTRY/GARAGE WALL. 10/05/17 ROSE PASS P004 PLUMBING GAS TEST 10/05/16 FOLG PASS Z003 CO PLANNING INSPECTION v 201800245 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ss^^ CERTIFICATE OF OCCUPANCY DATE: 07/18/2018 GIS ID:53450020 1f 1 1 J1 _ `" �' ^`i. - FEE: 10.00 MUNIS APPLICATION# 201 1418 YYY >, _ BUILDING DESCRIPTION: APPLICAN `9 ' y 1 ` LOCATION NAME: T&M BUILDING CO;INC. : g' _w ADDRESS: °ZO ,EXIE LANE ADDRESS: 110 BROOK STREET WNER. T&M BUILDING CO INC TORRINGTON,CT Q 79�o �010$ROOK STREET - TORRINGTON,CT 06790 A i*i 55 DESCRIPTION OF WORK: COSTF tfbf INGLE.FAMILY,TOWN HOUSE%,gT 2$EDROOMS,2 1/2 BATIS,,ATT'ACHED TANDEM 2 CAR GARAGE AND DECK.ASHFORD STYLE. y s •s._..t9 SPECIAL CONDITIONS: UNIT tS4 << ALL WORK TO BE DONE IN ACCORDANCEsWITH>,THE'APPLICATION AND,VLANS."PROVED B THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: [m ,` ;� y' _ = OCCUPANCY GROUP: ==-z �' BUILDINf OFFICIAL 7/18/2018 9:17 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE jo Let-,e. ,�, SITE COMPLIANCE CHECKLIST �3 TOWN OF SOUTH WINDSOI,CONNECTICUT *****BUILDING PEr,,1ATT***** gpU(i{WIN0S0RPLA N1.1NG 0EEFT. L ADDRESS Z� 3 �-2x�e l k�_LOT/UNIT r� -Neviewed b En ineerin .� Yam_( 9 9) CONTACT/DEV,T� 0 U ( 1n, Date Reviewed �,Pecl/Denlecl PH# g� Z Reviewed by (Planning) Date Submitted O I(P Date Reviewed/O S /I-CA45EiR/Denied. Reviewed by (Health Dept) Date Reviewed Approved/Denied In accordance with the Zoning and/or Subdivision Regulations,prior to the building of any stricture on a lot,a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name,address&phone number of / owner/applicant 2. Name,address&phone number of plan / preparer 3. Zoning Information—Le.zone,open space, / floodway,street address 4. Plot Plan at 1'=40'scale A. Subdivision reference,abutting properties,.etc. / b. Easements of record C. Lot description,bearings,building lines, distances,area,etc d. Contours,existing&proposed,1 Or 2fL Interval where appropriate —yam e. Building location witfi dimensions.Elevations of proposed finish floor,garage floor¢erline of road at driveway f. Elevations of gravity drainage systems,sanitary &foundation drain at the house and the street g. Tentative utility location(gas,water,electric~ / septic system,etc- h. Title block with name&address of preparer, date,appropriate certification,live seal&live signature consistent with the Board of. Registration requirements.(P.E.&L.S.) S. Sedimentation and erosion control 6. Special Planning&Zoning,Inland/Wettands considerations(Plans on file w/Town Clerk) COMMENTS: s/engineering/molloy/building compliance checklist LANE 133 PLACE -`� 7GAR=67.3 49 GAR=68.6 •O -� F.F.=67. F.F.=69. 1. CONTRACTOR SHALL VERIFY LAYOUT DIMENSIONS. ANY 42 LEXIE IDISCREPANCIES SHALL BE REPORTED TO THE DESIGN ENGINEER LANE C.B. YPE 'C-L' 0 32 183 PEPIN AND ARCHITECT PRIOR TO CONSTRUCTION. F.F.=67.8 INV. T.F.=65.2 IPLACE2. CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL 63.8� GAR=67.3 L.=63.04 F.F.=69.1 UNDERGROUND UTILITIES WITH RESPECTIVE UTILITY COMPANY. INV. WATER - METROPOLITAN DISTRICT COMMISSION INV=64. h 31 GAR= .6 129 SANITARY - TOWN OF- FRONTIER ER SOUTH WINDSOR WPCA 179 PEP COMMUNELECTRIC - FRONTIEVERS URCE sj PLACE INV.=6 NATURAL GAS - EVERSOURCE F.F.=69 GAR=68. 3. REFER TO SITE PLAN DRAWINGS FOR EXISTING CONDITIONS 86.5 i 130 75 PEPIN INFORMATION, OTHER PROPOSED SITE FEATURES, AND EROSION PLACE CONTROL MEASURES. 16+, sO� ` ` F.F.=69. 4. REFER TO ARCHITECT DRAWINGS FOR DETAILED BUILDING INV.=64.0 Q 171 DIMENSIONS. 36 LEXIE F. 5. ROOF LEADERS SHALL DISCHARGE 70 SPLASH BLOCKS AT GRADE. LANE 6. SETBACK REQUIREMENTS BETWEEN BUILDINGS SHALL COMPLY WITH F.F.=67.0 51 1&4 SOUTH WINDSOR ZONING REGULATIONS. INV.=61.7 GAR=66.5 s: INV.-- 32 LEXIE PROPOSED UNDERGROUND UTILITIES �'-6"PVC 61.9 LANE �\010 -3 S=0.02 EU ELECTRIC & COMMUNICATIONS F.F.=67.0 15 ROOF LEAD �Sy INV.=61.6 (DISCHARGE 0 1" DOMESTIC WATER SUPPLY > GAR=66.5 28 LEXIE (TYPIC NATURAL GAS ss LANE ss F.F.=67.0 53 '- 6" PVC SDR-35 SANITARY SEWER INV.=61.6 O �' `S 24 LEXIE \ roly r,,i �9• GAR=b'6: •�OF coN/yE LANELl y;9cr�c; O S F F.=67.0 C. TYPE 'C- ; ;o) o• - O52 �6', GAR=.5 154 T.F.=6 4 _"';1%k o, INV.= > �i�s ,o INV.=62.6 -62. 61.3 2 LEXIE I ; 'o'• 27475 ; 5p F � 0 •O .F.=67. 0 3 S M N > INV.=62.5 16 LE�tE PIAP REFERENCES r 6. ,, / 1 STA. 7+50 GAR=6 5 , C ,� LAN /. GRADING PLAN SOUTH W/N R W DS PLEAS VALLEY ROAD SOUTH AVINDSOR CONNECTICUT SCALE.• T.F.=65.59 O F.F.=67.0 1'=40' DATE 12/20/13.PREP4IRED FOR T017 BUILDING z� .64�=6 INV.=62.8 CO. 11vC. no BRco,< STREET TORRINGTON, =59.09-8" \ F 19. GAR=66.5 CONNECTICUT 06790 DES/GN PROFESS/ONALS, INC. 9 C.B. TYPE 'C-L' 5URVEY NOTES ' STA. 7+25, 9.9' RT. > ILT f �. � T.F.=6 4.86 s (NPI /. THlS SURVEY AND MAP'NA5 BE�TI PREPARED PURSUANT TO THE REGULA T10N5 OF COVNEC-tICUT 5TA TE AGENCIES F.L.=6 2.35 o' a+ � 8 x10 SECTIONS 20-3006-/ THRU.20-3006-20 AND THE STANDARDS C.B. TYPE 'C' \ S INV.=6 5 PATIO FOR 5URVEY5 AND MAPS IN ,THE STATE OF CONNECT/CUT' TA. 7+25, 12' LT. STORM MANHOLE 8'xto A5 ADOPTED BY THE CONNECTICUT A550CIATION OF LAND SURVE)IORS, INC. ON 5EPTE/IBER 26, 19R6. � T. =64.80 � STA. 6+00, 6' DEC L.=61.9 F.L.=65.83 TYPE OF SURVEY 15 AN 117PROVE11ENT LGCAT/ON aR 5URVEY - PROPOSED.- AMP 15 INTENDED TO DEPICT �h F.L.=61.54-1 THE LO ATION OF PROF05ED INPROVEI'1ENT5 RELATIVE ,2. X F.L.=61.29 TO PROPERTY LINE5. ; g 1" WATER\ 65.8 ii TN15 /5 A RESURVEY BA5ED. ON MAP REFERENCE 01. �e SERVICE & • NOR/ZONTAL ACCURACY l71EET5 CLA55 A-2 5TANDARD5 j CURB STOP N' \ , AND VERTICAL ACCVRA•C�'MEETS CLA55 T-2 (TYPICAL� \(�` � � STANDARDS. ` S X 4 LEXIE WAY TO Mr KNOWLEDGE AND BELIEF TN/S MAP 15 SU TANTIALL r CORRECT nor° .9 F.F.=67.0 AS NOT D HEREON. • X �' 31 Gv . .�• O ,p 12327 Z2• �� '�� _ S� \�S. ���OyS �� LAWRENCE R. GEI55LER, JR., 1.5. L/C. WO APPLICATION FOR.,ELECTRICAL-PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Applica ' e BUILDING DEPARTMENT 170 a.3 3 3 D 1:540 SULLIVAN AVENUE W-2511.ext. 230 Bldg:Permit# JI 067(Z ate wilding Inspector , Application must be printed or typed FEE SCHEDULE /l Location'of Job: $0-$1,000=.$15.00 0�(� Le,bz-ie L-anc /5 Over,$1,000= Street No. Street Lot No. $15.00.per$1,000 . or any fraction thereof Tenant Designation Apt.No. APPLICANT Z&-T NMASUti APPLICANT ADDRESS _22 APPLICANT'S PHONE# 96 0- 930 -02 2 SOWN S OWNER Tj/4 '3ujGAER:S OWNER ADDRESS l/b ,b/OpX S7 a je4 AJC.TO nl C7- G6 796 C OWNER PHONE r13 Z534/ Q.. ESTIMATED COST$ 51 a O O b U IS THIS A CONTRACT COST? Yes No GFEE ENCLOSED-$. 16Z TYPE OF JOB: OR-COS New Installation Alteration/Addition/Repair OIL 014q Revised 03/05/10 APPLICATION FOR ELECTRICAL PERAHT(Continued from reverse side) TYPE©F BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑ RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑. ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY O.STORAGE ADDRESS ❑ GARAGE ❑ rDCED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION!WIRING METHOD SIZE OF SERVICE o?DU `P SIZE OF MAIN CONDUCTORS J 6 NUMBERS OF METERS NUMBERS.OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONIdE4TS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS .NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER'OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUSTBE SUBMITTED. DESCRIPTION OF WORK NCli✓ SEQ /Ilvd W/KIE tJN i T THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK cT_ CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT /�id�"�-� DATE 9 " Z S � DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 000-NI BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE 644-2511 EXT.230 Bldg.Pemut# 16QU7IZ (Date) (Building Inspectory Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot.No. Over$1,000- $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT �791y e- IGZ APPLICANT ADDRESS -/r7r^^� �� C i ©LPD3� APPLICANT PHONE# Coo r� I OWN $F,q OWNER �- m � ►�4 / OWNER ADDRESS /I I D R rpe, c S !, CO) y OWNER PHONE D C r ESTIMATED COST $ IS THIS A CONTRACT COST? YYES NO G FEE ENCLOSED$ 135' TYPE OF JOB: xf 530 3- �SOR•COS xNew Installation _Alteration/Addition Repair V'ZO 1 to 014 J`u Revised 12/22/11 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A O RESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES ❑ NO O BUSINESS CURRENT USE AND OCCUPANCY O ASSEMBLY O MERCANTILE O EDUCATIONAL FUTURE USE AND OCCUPANCY O FACTORY O STORAGE ENGINEER'S NAME PHONE O GARAGE O MIXED USE ADDRESS (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION N(-co PI-3rn R u- SIZE OF MAIN DRAIN NO.OF TOILETS STYLE ,,j A C N~'k s NO.URINALS STYLE NO. OF BATHTUBS NO.OF SHOWERS a NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS / SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES / KIND /-, -f c�-, j ""/- ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW O YES O NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK �Q too r SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE (L MANUFACTURER c 7-r( DESCRIPTION OF WORK ��m/3 zy -t.• P.1�w Z JI , .6-+4%rt THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. o� `4e4 - 1 ct CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT -'� DATE �/�f t '7 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: i�(fjby�3 BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 (�6 C)7 l Z Date ' Building I r Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$I5.00 F:TFenant Street Lot No. Over$1,000 $15.00 per$1,000 or any fraction thereof nation Apt.No. APPLICANT 411 m c c, �� •.ti�i nn� APPLICANT ADDRESS /; ' G 1• 6352 , Wo(co+4- c,7 0c2/( APPLICANT PHONE# 20-3" G l`1 -1- 9, ��W N Se OWNER T - m OWNER ADDRESS I I c) Cf 7- C 679m OWNER PHONE C ESTIMATED COST$ xa, IS THIS A CONTRACT COST? VYes _No `G a �G FEE ENCLOSED$ 16 ~ rry�S o TYPE OF JOB: S10S OR C V-NewInstallation _Alteration/Addition/Repair r APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPR OF SYSTEM: TYPE OF BUILDING: HEATING CIRESIDENTIAL OWC Cl COMMERCIAL C VENTILATION Cl INDUSTRIAL HEATING ❑ STEAM LOW PRE SURE LIMIT LBS. HIGH PRESSURE, LIMIT LBS. ❑ HYDRONIC 0 WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE °F TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) G-occ(��L�r, �L�c`yo �Gtv1�S9EC�yO,t13n'� GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY Cal GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE :SIGNATURE OF APPLICANT «� _ -DATE �� Ywri htso Project Summary o� � � abe. August 01,2017 9 Entire House By. SaimirAgo ALL AMERICAN HEATING &AIR CONDITIONING 770 BOUNDLINE ROAD,WOLCOTT,CM 16 Phone:203-879-4928 Fax:203-879.4920 Email:allaniericartvac5@aol.com Web:wwwallarwricar ieati aircor dMori .com License: . CH1 n9 ng Pro*ect Information For. T&M Homes 20 Le)ae Lane,South Windsor,CT 06074 Notes: Design Information Weather. Waterbury,CT,US Winter Design Conditions Summer Design Conditions Outside db 2 OF Outside db 85 OF Inside db 70 OF Inside db 75 OF Design TD 68 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 29 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 40014 Btuh Structure 15239 Btuh Ducts 2498 Btuh Duds 552 Btuh Central vent(0 dm) 0 Btuh Central vent(0 dm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 42513 Btuh Use manufacturers data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 14211 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 1 (Average) Structure 1757 Btuh Ducts 1088 Btuh Central vent(0 dm) 0 Btuh Heatingg coolingg (none) Area(ftl) 1735 1735 Equipment latent load 2845 Btuh Molume(ft) 16621 16621 Airchanges/hour 0.33 0.14 Equipment Total Load(Sen+Lat) 17057 Btuh Equiv.AVF(dm) 92 39 Req.total capacity at 0.80 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating Input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent000ling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 829 cI i Actual airflow 829 cfm Airflowfador 0.019 dm/Btuh Airflow factor 0.052 dm/Btuh Static pressure 0.30 in H2O Static pressure 0.30 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft' Right-SUte®Uriversal 201717.0.23 RSU17966 2017-Sep 11 OPat9 e8 ♦1CCP. ...ersft11y)Des1dop\WrightsoRProjeets\2Torimp Calc=MJ8 Frort Door faces:N • ALL AMERICAN HEATING • AIR CONDITIONING, INC. P.O. Box 6397 Wolcott, Connecticut 06716 Phone: (203) 879-4928 Fax: (203) 879-4920 CT License#303291 CT License#391792 CT License#203918 Date Ocf���lll I,Jay Valimont Sr, hereby grant permission to �Cl-i M I c 0 to apply for a HVAC permit in the town/city of i ry-&o c- using my S1-0391792 license for the address 9,c) LeA t'e L .-� e_ Sincerely, 1 Jay Val o t Sr President STATEi HEATING,PIPING&COOLING UNLIMITED CONTRACTOR JAY C VALIMONT SR PO BOX 6397 WOLCOTT,CT 0671"397 LIC./REG NO. EFFECTIVE EXPIRES HTG.3 179j;!� 09 01/2017 08/31/2018