Loading...
HomeMy WebLinkAbout20 CHRISTINE LN Electric# 29 MJSV�IeTar�ATION FOR BUILDING PERMIT Plumbing# Date: lU •' L' b�? HVAC # 8 Sprinkler# U :2 ) Estimated Cost $ pFINAL APPROVALS — -- tabu— Building CO L AREAS Permit Fee $ `4 S EnEngineering Occupancy Fee $ I[� In g TYPE OR PRINT ONLY i Eng. Insp. Fee $ Affidavit SIGN ON REVERSE SIDE SS Appr. for CO. Total Fee $ - - - -- - - - TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant ,a r Z- Location of Work Lot No. Applicant's Add ss CL.r,1311n.{ I,CA "e_ Tel.# t{3`L- '2+L 5- Town Zip nL,,-)4-A Lic.# Owner LQ Z Architect Owner's Add ess Zo U, —E— Architect's Address I%L4. W.,Aee. Zips Zip Sq. Ft. New Area: 1st FI. 2nd FI. 3rd FI. Total New Area Purpose of this permit - Q City Water❑ Well❑ Septic System❑ Sewer❑ Ins: HO S Cert. Area Basement Garage Approved by Date Ci Use Group Construction Type Revised 6102 i hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances, the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Buildinc, 'or which this permit is asked,and agree that this building is to be located the proper d e from all street lines,side yard In �s,and required distances from all other zones and is locatedMwbuilding an s all ed. Signe I hereby apply for a Certificate of Occup ncy for w described in this ap ation for the permit Signed 'b4; - - DON T WRITE BELOW THIS LINE INSPECTION COMMENTS /V- c' i i r AND CGS 29-393 LOT 18 S 72° 0 8'- 51"E 148 .95 � I m 2 O Y Qc LOT 8 Q a W Q Z W ti to p1175 (3) 1�' W t� O N M 1p m _ a6 N 4, /0 lV o, � 65 0� Lw 0 ^ \ J cc 36.42 Z (f) Q � Z z 50' B.L. V o a=901900.00' Z R=15.00 T=15.00 135 .00 A=23.56 S72°08-51 *E ROSEMARY L A . PROPERTY OF i NO CRISTINE LANE SOUTH WINDSOR, CONN. BEING LOT 8 ON MAP ENTITLED " OAK GROVE ACRES, SECTION NO Zz- OWNER 8 DEVELOPER CARLO PRESTILEO , ROSEMARY LA. 8 CHRISTINE LA., SOUTH WINDSOR, CONN. , SCALE.'I"= 40', DATE: 8-21-73 , GRISWOLD ENGINEERING INC. SCALE: 1 40 ' JUNE 18, 1975 KENNETH R. BOUD L.S. FOR BUILDING PURPOSES ONLY o/N/ �i N lv, •9� n '', �.' oucl O'3l 9 63 /� . ____, MANCHESTER, CONN. Specifications 'Note:If the hearth extension is flush with the floor(item F)it let must extend 19.5 in.in front of the body face(item E)(I1100, 13100&H2100 only). 11200 23" 19, 1 - 4' Note:Hearth extension width(G)is measured from edge 12400 25" 21-1/2' of fuel door to side of hearth. 13100 28' 25' 17' E Masonry&Factory Built Fireplace Clearances H2100 8' 20"(without legs) i The minimum required clearances to combustible materials 28" with legs) 6 when installed into a masonry fireplace are: FT i i Small11200 IF 20" 14' 7-3/8' 16' 1-1/2' 8' Medium 12400 11' 20' 12' 8' 18, 0.5' 8' Large 13100 13' 19' 18" 6-1/2' 16' 1.5' 8' Hearth Heater H2100 1 14' -1/2' 18, 1.5' I1200 TOP I2400 TOP I3100 TOP H2100 TOP �� _I I• 21-t14" -I 23.114 6r2 Flue­11 13-3l8' 11-1/8- Facepate 143/4'.� 19.318' (to fuel floor 318' Faceplate) 3/8" �� �=-I S5/8'• 1 g, 18"7-5/8-•• /2' 28- 22-3/4' I 34-114- •To fuel door opening •'Top surface depth Hearth Heater Minimum Fireplace Openings Firebox Height 18-3/4" 20-7/8" 22-3/4' 22-1/2" Height to top of Flue Collar 19-1/2' 21-1/4' 23-1/8' 20'(without legs) 28"(with legs) Regular Faceplate(W x H) 38'x 26-1/8' 40'x 30" 44"x 32' 40-1/4'x 30" Oversize Faceplate W x H 44"x 30-1/8' 48'x 33' 50'x 34-1/2' 48'x 33' ' including ashlip Maximum BTU" 55,000 75,000 80,000 70,000 Typical Sq.R.Heated 600-1000 1000-2000 1800-3000 800-1500 Optimum Efficiency 73.8% 77% 71% 72% 28-(vothW94 Maximum Log Size 18, 18' 21" 18' 2o"Mew Wgs) Burn Time(Typical)' up to 8 hrs up to 8 hrs up to 10 hrs up to 8 hrs Emissions(grams/hour) 3.Og 3.4g 4.2g 3.5g Firebox Size 1.4 cu.ft. 2.3 cu.ft. 2.9 cu.ft. 1.6 cu.ft. Flue Size 1 6' 1 6' 1 6' 1 6" 1 Illustrates Hearth Heater with classic leg option. ' Length of burn time and BTU range depend on type of wood,moisture content,climate conditions and instal- 2 2 lation. --tro-c -iserts ClassI.C .Mediul-1:1 �r No More Drafty Fireplace chill off quickly. Your Regency dealer will help STANDARD FEATURES Your open fireplace can allow as much as 90% you assess the right model for you. By working •EPA Certified •Black convection grill of your fire's heat to escape out the chimney. with an authorized Regency dealer, you will •Single rod draft control •Mobile home approve By adding a Regency®Classic Fireplace Insert, benefit from a professional who has been fully •Airwash system (I2400 only) you will keep the heat where you want it— in trained on the Regency product line and under- •Brick-lined fire box your home. Regency Classic Fireplace Inserts stands local codes and requirements so that your are ready for installation and fit easily into your wood insert will operate to its optimum. existing fireplace. This simple investment will OPTIONAL FEATURES increase the value of your home and decrease Cook Top Convenience •Cast iron door in gold,black, •Brass faceplate trim your monthly heating bill. With a large warming shelf,the Regency Classic gold accent or nickel accent •Nickel hinge caps anc Insert does double duty as a cook top for a kettle •Gold or nickel convection handles More or Less Heat or steamer. Even when the power is out, you grills •Regency stainless stee. The simple and reliable all-in-one draft rod can still cook a hot camp style meal and enjoy •Regular or oversize faceplate liner kit allows you to alter the airflow into the firebox so the heat. •Screen door •2-speed blower you can enjoy a slow burning fire with less heat or a crackling full fire guaranteed to take the For details please see page 22. Maximum BTU* 75,000 80,000 Optimum Efficient 77 Burn Time(Typical)* up to 8 hrs up to 10 hi ,. + ■ ■ ■ EIzsiQLaI �1slhcl;k..:• 4a _k �'; Firebox Size 2.3 cu.ft. 2.9 cu.ft. FI ,, I 6' ,}I Width 25' 28" w" 21-1/2" 25' Depth 17' 17' Length of burn time and BTU range depend on t,, of wood, moisture content, climate conditions a 12400,with black door,gold convection grills,brass 12400 with nickel accent door,nickel convection grills, 12400 with gold accent door,gold convection grills, installation. faceplate trim and blower. regular faceplate and blower. brass faceplate trim and blower. �� Opposite Page:The medium insert,model 12400,with gold door,gold convection grills,regular faceplate,brass faceplate trim and blower, The Forever Flexw . Solution Forever Flex ; chimney liner is the ultimate solu- tion to the problems that plague most chimneys. Modern stainless steel walls provide an airtight and watertight barrier ••,� - �' that seals in gases and •;� "' creosote. The EverGuard For- ever Flex liner is made of 100% 316Ti stainless steel. High quality stain- ' ' less steel combined with y .r Titanium creates an alloy to �1 withstand the acidic moisture and extreme temperature fluctu- ations inside your chimney. Forever 77 Flex will even contain a chimney fire! tR - (Actually, Underwriters Laboratories : (UL)tested Forever Flex, and has awarded its seal of approval. UL has declared that the Forever Flex system excels standards for chimney safety and can even withstand a 2100 degree chimney fire and still maintain structural integrity.) "= Forever Flex, and all EverGuard liners, carry the exclusive Forever Warranty, the first ! d I. warranty in the business that is transfer- able to the next homeowner. No fine print in this warranty,just peace of mind. Premium Chimney Liner with the Forever Warranty ' VOW r. FOREVER 100% „ U� wARRANTy Stainless Steel LISTED 10 THE BUILDUG DEPT. TOWN Of SOUTH WINDSON 'his cc+l,+i,J that this plan and specifications are true ecpres of the propu iid building or alleraDoris to bil erected at��,�f'� t—R�Iher wish amendments stated In application ana i 14.d with plan and 1 agree to comply with zoning, z-0-ling and state laws and such orders as yh.il! be 1--d by the Ruilding Department during pend,.ncy :+ tams application and final issuan3sn, permit. appro ed subject to tl,rd•rs d ,rdmances regulating b• d sith. 4mw Wunal!y Approved These filed with Building Inspecto( Cleft )sit• No. ���