Loading...
HomeMy WebLinkAbout20 BERRY PATCH BUILDING 2 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 1 i cbS -7 BUILDING DEPARTMENT APPRO 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Ooo Date Bu' mg Inspector Application must be printed or typed FEE SCHEDULE Location of Job: FTenant Berry Patch 2I $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 20 or any fraction thereof gnation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# (860) 623-1991 OWNER Berry Patch Associates Limited Partnership W S�q� OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, CT 06032 OWNER PHONE (860) 674-5641 C ESTIMATED COST$ IS THIS A CONTRACT COST? X Yes _No FEE ENCLOSED$ 1��5 . O�� TYPE OF JOB: OR.C X New Installation _Alteration/Addition/Repair Revised 4/01H2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 15 HEATING ❑RESIDENTIAL 21 A/C ❑COMMERCIAL di VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC In WARM AIR ❑UNIT RADIANT HEATER PER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION PLANS DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE T & TOTAL HEAT LOSS(BTUH) °F(IHIAT LOSS SHEET MUST ACCOMPANY SPECS APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Magic Pak M/N 51 H C 2431-213 GROSS HEATING CAPACITY(INPUT—BTUH)51,000 NET RATING(OUTPUT—BTUH) 41,000 TYPE OF FUEL ❑OH,—GPM OIL TANK LOCATION:❑ INSIDE❑OUTSIDE CAPACITY 3 GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING PER DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE °F PLANS TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) & DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) SPECS TONNAGE 2 COOLING CAPACITY(BTUH)24,000 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNEC 1CUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 303755 S-1 cr CONTRACTORS LICENSE NO. TYP STATE 7 anSIGNATURE OF APPLIC DATE DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: � --j a BUILDING DEPARTMENT 'ROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Build' Inspector Application must be printed or typed FEE SCHEDULE Location of Job: FTenant Berry Patch 21 $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 20 or any fraction thereof gnation Apt.No. APPLICANT Thwas L. Jacquel c/o Allstate Fire Sprinkler, Inc. APPLICANT ADDRESS P.O. Box 2350 Hartford, Cr 06146 APPLICANT PHONE# (860) 246-7711 O W N S Fq OWNER. Berry Patch Associates Limited Partnership OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr 06032 OWNER PHONE (860) .674-5641 C ` ESTIMATED COST$ •�, ` IS THIS A CONTRACT COST? X Yes _No CJ FEE ENCLOSED$ TYPE OF JOB: DSO R-C O� X New Installation _Alteration/Addition/Repair D....:—A A/AI/nnn'1 1 APPLICATION FOR SPRINKLER PERMIT (Continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES �RESIDENTIAL ' ❑BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERMIT APPLICATION? ❑YES ❑NO ❑MERCANTILE ❑EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑ STORAGE ❑GARAGE ENGINEER,S NAME David K. Thompson PHONE(860) 246-7711 ❑M]XED USE (Other please specify) ADDRESS P.O. Boat 2350 CITY Hartford STATE Cr ZIP 06146 KIND OF INSTALLATION SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? ®YES ❑NO IF YES,CHECK ALL THAT APPLY: MADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) Of PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES 0 NO IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑OTHER ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? W YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP NIA PSI DESCRIPTION OF WORK New fire sprinkler system in two bedroom unit THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. F10590 Fire Sprinkler Cr CONTRACTORS LICENSE N TYP STATE SIGNATURE OF APPLIC DATE L7 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT i Application' . ereby: TOWN OF SOUTH WINDSOR + BUILDING DEPARTMENT AP 1540 SULLIVAN AVENUE Bldg.Permit# 7_ 644-2511 ext. 230 '�o0 o j Date kguilding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: FTen:ant Berry Patch 2I $0-$1,000=$15.00 :No. Street Lot No. Over$1,000= 20 $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc, APPLICANT ADDRESS 56 Depot Street Broad Brook, CT 06016 APPLICANT PHONE# (860) 623-1991 Ow N SF OWNER sty Patch Associates Limited Partriership -44 OWNER ADDRESS 6 Executive Drive, Suite 100 FaLmington, Cr 06032 O ,` w.: ,-• '� •� � OWNER PHONE (860) 674-5641 ESTIMATED COST$ IS THIS A CONTRACT COST? X Yes No G FEE ENCLOSED$ TYPE OF JOB: SOR\Co X New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑YES ❑ NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4" NO.OF TOILETS 1 STYLE Elongated NO.URINALS N/A STYLE N/A NO.OF BATHTUBS NO.OF SHOWERS 1 NO.OF LAVATORIES 1 NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3 AREA OF ROOF Back NO.OF CATCH BASINS N/A NO.OF FLOOR DRAINS 1 Kitdien NO.OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES 91 NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Seer SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4 Weil Mclain WATER HEATER: TYPE Indirect MANUFACTURER P/US 120 DESCRIPTION OF WORK I HE UNDERSIGNED HEREBY APPLIES FOR A PERMI 0 1 '110 PERFORM THE WORK DESCIMM57=797T— COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P-1 00204480 P-1 Cr CONTRACTORS LICENSE NO. TYPESTATE OC T 1 6 2003 SIGNATURE OF APPLICANT / DATE DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT IT# Application is hereby: TOWN OF SOUTH WINDSOR PERMIT BUILDING DEPARTMENT PRO 1540 SULLIVAN AVENUE A� 644-2511 ext. 230 Bldg.Permit# 3 Ogg ate Building I ector Application must be printed or typed FEE SCHEDULE Location of Job: 20 Berry Patch 2I $0-$1,000 $15.00 Street No. Street Lot No. Over$1,000= ' $15.00 per$1,000 20 or any fraction thereof Tenant Designation Apt.No. APPLICANT J—Electric APPLICANT ADDRESS 8 Sanrico Drive Manchester, CI! 06040 -- APPLICANT PHONE# (860) 645-9891 O W N S Fq OWNER Berry Patch Associates Limited Partnership < OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr 06032 b Q �. OWNER PHONE (860) .674-5641 C77 ` e ESTIMATED COST$ 2,945.00 x IS THIS A CONTRACT COST? X Yes _No FEE ENCLOSED$ S,O R•CO TYPE OF JOB: X New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑YES ❑NO 91 RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY Residence ❑:EDUCATIONAL ❑INSTITUTIONAL � �rr;m ❑FACTORY ENGINEERS NAME PHONE ` (860) 257-3968 ❑ STORAGE 203 Briaxwood Court ❑GARAGE ADDRESS ❑MIXED USE CITY Rocky Hill l STATE CT ZIP 06067 (Other please specify) TYPE OF INSTALLATION/WIRING METHOD NMC SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8 NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23 NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS 1 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Interior wiring of apartuent to include outlets, switches and their cover plates. Wiring of appliances and HVAC unit. Install light fixtures. Install 100 amp breaker panel. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK 123580 E-1 Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Electric # 1 V sla l APPLICATION FOR BUILDING PERMIT Plumbing# 1 1375 20 Winterberry Lane (Building 2) Dater HVAC # I1,K5,� Sprinkler# l a 7 3L 30001 FINAL APPROVALS -_ — -- -- — _ --I Estimated Cost $ 38,000_00 BuildingPermit Fee $ COMPLETE RED BOXED AREAS i Occupancy Fee $ Engineering TYPE OR PRINT ONLY En . Ins . Fee $ ffi Adavit g p A r. for CO. ► SIGN ON REVERSE SIDE pp -� Total Fee $ --- -- - _ ___—' TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant The Metro Construction Corp. Location of Work '^�TatcWinterberry Lane Lot No.2T Applicant's Address 6 Executive Drive Tel.# 860-674-5640 Town Farnungt Qu, Cr Zip p 6-n33 Lic.# MOC)_9004�4 Owner-Berry Patch Associates L.P. Architect Associated Architect.-, Owner's Address 6 Executive Drive Architect's Address 16 sari ng Tanp Farmington, CT Zip 06032 Farmington, CT Zip 06032 Sq. Ft. New Area: 1st FI. 896 s.f. 2nd FI. --- 3rd FI. --- Total New Area 896 s.f. purpose of this permit New construction - multiple single family affordable dwelling City Water[k Well❑ Septic System❑ SewerW Ins: HO a t. Area Basement Garage Approved Use Group Construction Type Revised 6102 I a to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of hereby agree eq South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building o be boated the proper distance from all street lines,side yard lines,and required distances from all other zones and is located n h s building and its use is allowed. Signed -- I hereby apply for a Certificate o pancyffe the work described in this application for the permit. Signed u ` 1- ' DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-30001-B 22,000 BO1 FOOTING 10/02/03 WNB A B02 FOUNDATION 10/10/03 WNB A P03 ROUGH 04/28/04 PJP A PO4 GAS TEST 03/30/04 JFF A B04 INSULATION 05/11/04 JFF A CALLED ED ON CEILING TO BLOW IN REMAINDER OF INSULATION B10 FINAL 11/19/04 PJP A B10 FINAL 11/19/04 PJP A CLOSEOUT **-1272-5 1,000 **-11887-H 6,000 **-11375-P 5,000 **-11888-H 6,000 **-18581-E 2,945