Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
194 LISA DR
6/15/2021 ! R Town of South Windsor Building Department E- '4�tosot c°?r Building Permit: BLDP-21-392 APPLICANT NAME: Melissa Arel EMAIL ADDRESS: melissaa@rhinobackroofing.com ADDRESS: 532 HOPMEADOW ST SIMSBURY , CT 06070 LOCATION ADDRESS: 194 LISA DR South Windsor CT6074 OWNER: GAROFALO JOANN R 194 LISA DR SOUTH WINDSOR CT 6074 DESCRIPTION OF WORK: remove and replace existing shingles with new Owens Corning asphalt shingles,following code and manufacturer's recommendations. May 24, 2021 BUILDING OFFICIAL DATE SIGNED —ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT- -PERMIT ONLY VALID IF SIGNED BY BUILDING OFFICIAL— 111 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application ' TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT U 9(0 J NJ VED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 3ds�� Date Application must be printed or typed FEE SCHEDULE �p Location of Job: $0-$1,000=$15.00 {' Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. U'1'A APPLICANT Co R 5 D C I e c+r 1 c APPLICANT ADDRESS d 3 1-1 r) d$'A y I-An C- 3 rood Zr oo K C+ o l.0, 1 G APPLICANT PHONE# L) O W N S F,q OWNER S R L. G r\ r N FO(O OWNER ADDRESS ICI 4 l-1 5 A �D r So. W ✓�cl�i2, C--+ U r OWNER PHONE C ESTIMATED COST$ 9 D y u * IS THIS A CONTRACT COST? _Yesv No FEE ENCLOSED$ 06. 6z r��sO. O�� TYPE OF JOB: R C New Installation —�Alteration/Addition/Repair Revised 4/01//2002 JI APPLICATION FOR ELECTRICAL PERNUT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? 9 YES ❑NO RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY O MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL 0 INSTITUTIONAL 0 FACTORY ENGINEER'S NAME PHONE U STORAGE ❑GARAGE ADDRESS ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? O YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK 1Gvi�c S��� roo.-r, pc�d � -11o„ - 01u s!, 4- codz / a -fsl& e/vcq O ITS iat LIg(n+S L/- rcce'sScd 65h1s �naer6e -PAeN A/V/rt 5CLie (I wof 7�ylip SO Amp, THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT '( ��-- DATE /s 373 REINO E. HYYPPA 5 ASSOCIATES EMEES a LAND SURVECIVILYORS GL.ASTONBL RYA CON►il P7PO`.oE.fl WC>nOMAiZ Si NIF �7*- 2:4� CJO►.�6EribA'h4 .' GP�s ����qt�] k4 -� ,+,d`" �' 1 pd'.' it •e ..� �y y`' fi, �SFm'e '� s r-v �. -` (J r • t r a'- ,gyK tF.n. ��y�r �. rj Sol rj ,y �r°`"d � S��.a�'"=i� a,.1-6� ��S �" _ M► � ��r.•� s f ' q� y�e-F�''T t -FE,���. i „'i,�°� AS, Ilk sit 7-1 ;��"If?• -i,-t lX yi '+ 14,.`. Scb tJ _ rT 42 7 14 ' v . E _ pi iSTk ds"Or-- ," t a7 r L07 LL► EZ Fft5w N@v-,vj Pn.E^t!T:_E.^., p ? ur w .: •O�y�� �d•51+ 1 �'!v�y.� � `^'��$aF. t °P +��4 'tit t � _ r; ,,;� i � PL oT PLA7j -5cc-ini i MJJ-1:A w,(v E*t iv "w' 3 x # p• r, * $ EsTATES $rylTli MJ:wt':4Q,G +••�Y �, iFir Rr-too E. H.facie ! ASS0CIATE5 �:�E � r -Tt OV F:;U" PREPARED FOR kuN° T.R CART HILL REALTY INC E`,:GECT ��t_pt..Lab Loc1.'t,wl CERTIFIED '.sJBrTA.NTiAL0 C'MECT SOUTH W1NDSORt C(Y�IN. SCALE - 1"•40' OATE.. 1-l5-$%'a 58- fib- eo REINO E. HYYPPA 6 ASSOCIATES CiVI'l EMGINEEFtS a LAND SURVEYORS GLASTONBiRY, CON►ti PQbPO��f-� v�tCx'�0M At[ SL N fF C.01JCs�ECsAT tG� �3UPVNrS10►J .L �' NP\ I�RAEL., 1►JiC.. ' r i i N J' rj 1 • i Y► V ' a A �O � 1 ),/ . - N B8i t 'OoE-4 SSE 5-eD 4 Z.DrJE '•"'� F-.m PLAN ->: 3 Mno-iTWw E,,! Es-, TE, 5ojTH 04 w:SCQ,--rx� 'EY I� rz4O CA-E 9--V14c►AA= 60*1 ;L f,"EE'T 3 OF*)`.-EE7"5 WEQ PREPARED FOR N'nZ�lN4& A-b�� DART HILL FEALTY INC, CE:KTIFIED SLEEIA.NTiALLY COIZ+?ECT SOUTH WIWLSOFt C,ONN. - SCALE . I"*40 PATE _1-IS-SIc ;! �, F� 80 I �jd cJ�r7�� x isi cl) A P P R O V E D TOWN n`= SCIM-I Wit''_D-SOR ENCII'l=.-�INIG D`-?ArlTMENT DATE: l O5 (o REWO E HYYPPA 8 ASSOCIATES CIVIL ENG*dEERS S LAND SURVEYORS `3. GL.ASTONBURY, CONK `'����n � ,''� Ps��a�-O `rlo�Oc�AR 1L N IF CA►Jbe.�E6A���� o IZI 4. _ `_ �y �?' t s`: SU�ON�j1ow1 ♦z � ei'Np.� �;RAE�-, 1►-K.. * , AAA, � FL YT crb i JSL IT sn ,�� { i n ry J y,.p} ri 1. .( rL 3 _Ai x i "' 34t r goo.QO BIB — —� —� — — L MA.. , FILE t�' ;�... 4 I L4►4 f tT 17N ij ESTATE5 SouTH Witio5oe,Zo*J -"e'y R wo E. -`w +e i Assxtta;E� Sr�,F I4240 DA-E.SAS AC,M P Svc 1804= ;-ErT 3 oF9!�. EE-t +x� -ZI-ems PREPARED FOR T=vk4 t-OCK"TEP 4.5 �N,•� vto�,, .�� W1TH T. DART HILL REAL T Y INC R�GELT �1�..p��lc, L�ocl►Tlo.J CERTIFIED yjB_=1A-NTiALL1 =RRECT SOUTH VNDSOR, CO IN. SCALE 1''•4C [)ATE. —1-1S—Q�� to- FE- 60 i DATA' SIG.: REINO E HYYPPA 8 ASSOCIATES CIVIL ENGINEERS a LAND SURVEYORS GLASTONSLORY, CONK PQODO'�L.D ,1,1o0vt RAC 3� I ,,IV: cop GEE6AT�0� 3qL I �51 I 3 r j I I I 1 i >J -� L N LPr rJ 2 1• P o 4�ov'yE /I r44-A; - - I O a Q I9 �q� 1C70,Q4 38 W -- - - Jam+.;awcR j j LDT Lwfl-c FRw F-i�E T.-Ems, - _----- — 'OoE++Sa.:.£ JJWD 4,5S9N 1.-30 lo"E PLtr Puw `ter,a; 3 M nkor iE V: EsTATE5 SOw-►TH Yv;r�:.l t arxx'eY 1'=40 :AA'-E 8-13-t%cWAr- ISO :L �+;�T � oa"9`«-�E.E-Y >zE� z-z►-ems PFt PA E RED FOR DART HI' L READ..T Y INC. CEPTIFIM `s-e!�IANTIALLy CORM , . SOUTH WINDSOF', CONN. psi � $Y1 "r°•� s ' � "A-F 1' �4C pATE: ,APR ,' 2 24G4 South Windsor BUILDING DEPARTMENT „_ �..,.;;,iw marl. 1i:►rft Ue sii- .k u�vY?c nos certified tnat tnia Man and •"1'>na Mrs Uvu -c.l;ies of the proposed buil0106 or aitaraWns b r -tted at ;p ther with amendments stated In applicatton and u,d wit to plan and I agree to complY with all aoning, ,i,itng and state laws and such oroers es shall be :-�.-0 by the Building Department during pendency t T,is application and final issuance of a build egned "us Dian Is approved subject to the condition that +:rs :,no rdonances regulatin` building shall be _onditionally Approved The" "led Wttk Buildlrag Ineperta( Clar'� awl "• 7 ,,,IY �r TUNING COMPLIANCE Pio, us: s) andlor structures) as syr: Y: I o' in appear(s) to be in conform_.;:;. ' I .j rent SoLith Windsor regulations. :to a d special exceptions may apply. Date c( Q� r►g of cement Officer s 3 '13 REINO E. HYYPPA B ASSOCIATES CIVIL ENCMEERS lk LAND SURVEYORS Gt_ASTONBLiRY, CONK PP_pP0'�E.fl �tdQ40MAQ. �L ' Oil: sport/5 tow B�Nay �SRAE� c,1 j'4L t v N 88'S5�0c:v T- i r � 3 Q = ;IN co N a ts fill sous E �' 0 t L _ I ty -54t- �pO.t7p — - —N Bsa n 8, 3e W � 5riN � Lorl LAW FRNA&At,g:'.-VN F1LE fiLEt:, PLOT PLA�v 5uttia, 3 MOJN:s.s►a n�v: E5T4-rE5 5 Kj H W:►J��,C--*Wry Rr-uJoE. H`^7P;x I issxmlE5-5rA.E `tiHEET 3 OFF!aH EcT': QEV 2-z1-84 ��I..ocnzEsi 1�S�aoW.J tio-^ft•8�o'�.i PREPARED FOR CART HILL REAL C I Y C>rRTIFIM suielANiIA iy 'C,VRF-CT. SOUTH WINDSOR, CONN. SCALE V-40• pATr. DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# TOWN OF SOUTH WINDSOR i n is BUILDING DEPARTMENT 1 Z 1 1540 SULLIVAN AVENUE Bldg.Permit# d 0Q 644-2511 ext. 230 N,A Date Buildi Inspector v Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT C A APPLICANT ADDRESS G-t'o.1l(kvvl lPkkCe-- APPLICANT PHONE# _ 26c) - C a\"q 313 OW Ni SF4 OWNER Sod\ . GUCC;l17y1C7 OWNER ADDRESS /Q 'D r k OWNER PHONE RCO C = ESTIMATED COST$ ) SOJ IS THIS A CONTRACT COST? _Yes C-90 FEE ENCLOSED$ TYPE OF JOB: SOR.CO _New Installation Alteration/Addition/Repair Revised 4/01H2002 4 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING ❑RESIDENTIAL r ❑A/C ❑COMMERCIAL 9'GENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR Cl UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE °F INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) r e ri- v Q V-\-t— TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) n � FURTHER DESCRIPTION OF WORK cp �Qv1 S Tc t u, L, THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. S S 73�(o kvvke.-"-V�yv,D rc.er+l CONTRACTORS LICENSE O. TYPE STATE SIGNATURE OF APPLICANT DATE �� I • 340 17116 STATE OF CONNECTI ( UT - DEPARTMENT OF CONSUMER PROTECTION r 165 Capitol Avenue ♦ Hartford Connecticut 06106 Attached is your registration. Registrations are non-transferrable. Such registration number shall be displayed in a conspicuous manner on all printed advertisements. To report an address change, please contact the Depirtment of Consumer Protection, Licensing Division at(860) 713-6000. Visit our web address: www.dcp.state.ct.us/licensinz/for information and applications. STATE OF CONNECTICUT DEPARTMENT OF CONSUMER PROTI-.CTION HOME UNUROVENWIgT CONTRACTOR CT APPLIANCE&FIREPLACE DIST LLC CT APPLIANCE& FIREPLACE DIST LLC so GRAHAK4 PL 50 GRAHAM PL I SOUTHrNGTON2 CT06489 I SOUTHINGTON,CT 06489 _ LI FF IVE�. �EXPIFRES 557346 12/01/20030/2004 " 0 SIGNED_ - bur_ - - -i STATE OF CONNECTICUT ♦ DEPARTMENT OF CONSUMER PROTECTION i Be it known that i CT APPLIANCE & FIREPLACE DIST LLC ' 50-G> 2 R,, SQIITHINC`�`Ol T06.489 has been certified by the Deparhxlat of QbstTter Protection as a registered HOME IMPR _ T CONTRACTOR j Regis#ratYb ,- 73 46 TRanisr (�< Effective: 12/01/2003 Expires: 11/30 2004 - Ja T.Fleming,-Comm• sioner - I W INSTALLER/CONSUMER MA E IC SAFETY INFORMATION PLEASE READ THIS MANUAL j ST BEFORE INSTALLING AND WRMqYNT USING APPLIANCE WARNINGI � IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING Rear Vented SONALPROPERIN URTY Y OR LOSS OF Direct Vent Gas Fireplace LIFE. Model: DVR3 3 FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor's phone. Follow the gas suppliers instructions. � • If you cannot reach your gas '° supplier call the fire zazs department. Homeowner's Installation and DO NOT STORE oESwN Operating Manual OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY sp OF THIS OR ANY OTHERTtO °•• ••° APPLIANCE. Vermont Castings, Majestic Products 410 Admiral Blvd.•Mississauga,Ontario,Canada L5T 2N6.905-670-7777 www.majesticproducts.com.www.verrnontcastings.com INSTALLER: DO NOT DISCARD THIS MANUAL- LEAVE FOR HOMEOWNER 10004920 01/03 Rev.0 Vermont Castings, Majestic Products: DVR33 • - of • PLEASE READ THE INSTALLATION &OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE. Thank You and Congratulations on Your Purchase of a Vermont Castings,Majestic Products Fireplace. IMPORTANT. Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation and Operating Instructions Important Curing/Buming Instructions ........................................................................ 3 Proposition65 Warning............................................................................................... 3 Locating Your fireplace..................................... Fireplace Dimensions.................................................................................................. 4 Clearance to Combustibles ......................................................................................... 5 Mantels........................................................................................................................ 5 Hearth ........................................................................................................................ 5 Framing& Finishing .................................................................................................... 6 FinalFinishing............................................................................................................. 6 GasSpecifications....................................................................................................... 6 Gas Inlet and Manifold Pressures ............................................................................... 6 GasLine Installation.................................................................................................... 7 Remote ON/OFF Switch Installation........................................................................... 7 AlternateSwitch Location............................................................................................ 7 EB-1 Electrical Box...................................................................................................... 8 Electronic Gas Control Valve ...................................................................................... 9 General Venting Information/Termination Location/Clearances............................. 9—11 General Information for Connecting Vent Pipes ............................................................... 11 Crimped End Pipes/Twist Lock Pipes................................................................. 11, 12 Rear Wall Vent Application/Installation .............................................................. 12, 13 Howto Use the Vent Graph ...................................................................................... 14 Vertical Sidewall Application/Installation.......................................................... 14—17 BelowGrade Installation ..................................................................................... 17, 18 Vertical Through-the-Roof Applications& Installations ....................................... 18, 19 DVR33 Bracket Restricter Installation............ .......................................................... 20 Twist Lock/Crimped End Venting Components.................................................. 21. 22 Operating Instructions GlassInformation ...................................................................................................... 23 LouvreRemoval ........................................................................................................ 23 Window Frame Assembly Removal .......................................................................... 23 GlassCleaning.......................................................................................................... 23 Installation of Logs and Lava Rock Material.............................................................. 24 Flame and Temperature Adjustment......................................................................... 24 Flame Characteristics................................................................................................ 25 Inspecting the Venting System.................................................................................. 25 Lighting and Operating Instructions..................................................................... 26, 27 TroubleshootingGuides .................................................................................... 28—30 Fuel Conversion Instructions..................................................................................... 31 GeneralMaintenance................................................................................................ 32 Cleaning the Standing Pilot Control System ............................................................. 32 Replacement Parts PartsPictorial ................................................. .................................................... 33, 34 PartsNumber List............................................................................................. 34—36 Optional Accessories FanKits..................................................................................................................... 37 HardWire(Direct) Hook-up....................................................................................... 37 RemoteControls ....................................................................................................... 38 Ceramic Refractory Panels ....................................................................................... 38 DecorativeBay Windows .......................................................................................... 38 Decorative Frame Trims............................................................................................ 39 10004920 Vermont Castings, Majestic Products: DVR33 +' Installation • Operating Instructions m This gas appliance should be installed by a qualified installer PROPOSITION 65 WARNING in accordance with local building codes and with current CSA- Fuels used in gas,wood-burning or oil fired appliances, B149.1 Installation codes for Gas Burning Appliances and and the products of combustion of such fuels,contain Equipment. If the unit is being installed in a mobile home,the chemicals known to the State of California to cause installation should comply with the current CAN/CSA Z 240.4 cancer,birth defects and other reproductive harm. code. For U.S.A. Installations follow local codes and/or the if Calorni He alth ealth 8�Safe Code Sec.25249.E current National Fuel Gas Code.ANSI Z223.1. Safety FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: This appliance may be installed in an aftermarket, 1. This fireplace gives off high temperatures and permanently located,manufactured home,or should be located out of high traffic areas and away mobile home where not prohibited by local codes. from furniture and draperies. This appliance is only for use with type of as 2. Children and adults should be alerted to the hazards indicated on the rating plate.This appliance is of the high surface temperatures of this fireplace, not convertible for use with other gases, and should stay away to avoid burns or ignition of unless a certified kit is used. clothing. 3. Children should be carefully supervised when in the IMPORTANT:PLEASE READ THE FOLLOWING CAREFULLY same room as your fireplace. 4. Under no circumstances should this fireplace be Remove any plastic from trim parts before fuming the modified. Parts removed for servicing should be fireplace replaced prior to operating this fireplace again. It is normaall for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or 5. Installation and any repairs to this fireplace must be cool down cycle.Similar noises are found with your furnace performed by a qualified installer, service agency or heat exchanger or car engine. gas supplier.A professional service person should It is not unusual for a Vermont Castings, Majestic Products be contacted to inspect this fireplace annually. Make gas fireplace to give off some odor the first time it is burned. it a practice to have all of your gas fireplaces This is due to the manufacturing process. checked annually. More frequent cleaning may be Please open all windows to ensure your room required due to excess lint and dust from carpeting, is well ventilated. bedding material,etc. It is recommended that you bum your fireplace for at least 6. Control compartments, burners and air passages in ten(10)hours the first time you use it. If the optional fan kit this fireplace should be kept clean and free of dust has been installed, place the fan switch in the"Off"position and lint. Make sure the gas valve and pilot light are during this time. turned off before you attempt to clean this fireplace. Your _ 7. The venting system (chimney)of this fireplace ' place should be checked at least once a year and if needed your venting system should be cleaned. 8. Keep the area around your fireplace clear of com- I E A a bustible materials, gasoline and other flammable Y vapor and liquids.This fireplace should not be used x as a drying rack for clothing, nor should Christmas c stocking or decorations be hung in the area of it. 9. Under no circumstances should any solid fuels YI (wood, coal, paper or cardboard etc.)be used in this x e fireplace. F 10. The flow of combustion and ventilation air must not be obstructed in any way. `u584-R 11.When fireplace is installed directly on carpeting, vinyl Fig.1 Locating Your Gas Fireplace tile or any combustible material other than wood,this A) Flat on wall B) Cross comer C)Island** fireplace must be installed on a metal or wood panel D)Room divider*/** E) Flat on wall comer* F) Chase installation extending the full width and depth of the fireplace. Notes(Fig. 1): Y)6 in.minimum 12.This fireplace requires adequate ventilation and *When you install your Vermont Castings,Majestic Products fireplace in combustion air to operate properly. (D)Room divider or(E)Flat on wall comer positions,a minimum of(Y), 13.This fireplace must not be connected to a chimney 6 in.(153 mm)clearance must be maintained from the perpendicular flue serving a separate solid fuel burning fireplace. wall and fhe front side edge of the fireplace. 14.When the fireplace is not in use it is recommended **Island(C)and Room Divider(D)installation is possible if the horizontal that the gas valve be left in the OFF position. portion of the vent system(X)does not exceed 20 ft.(610 cm).See details in Venting Section. 3 Vermont Castings, Majestic Products: DVR33 r 'Fireplace • Rough $ 'E 4"Dia.(102mm) Opening i 7"Dia.(178mm) Depth , -T L G �F O Recessed Nailing Flange ,�. .Rough Opening Width 331,V (16mm) (13mm L Rough M Opening Height 1 (25rmi) B P C B �H Electrical R Gas Line T Access Access ti � (1Q2mm U --I r �—D J I J 2•(szmm) (52mm) A Q—'-11�tom) K— Fig.2 Fireplace specifications and framing dimensions. Appliance A 33" 838 mm B 287/8" 733 mm C 16%" 416 mm D 31" 787 mm E 221/16" 560 mm F 111/2" 292 mm G 143/4" 375 mm H 241/2" 622 mm 1 5" 127 mm J 71/2" 127 mm K 81/2" 216 mm R 31" 787 mm S 161/2" 419 mm T 191/2" 495 mm U 8" 208 mm Framing Dimensions L 36" 914 mm M 51" 1295 mm N 251/2" 648 mm O 12" 305 mm P 29" 737 mm Q 331/2" 851 mm 4 10004920 Vermont Castings, Majestic Products: DVR33 " Clearance to Combustibles Appliance Top 0"(0 mm) Bottom 0"(0 mm) Side 0"(0 mm) Back 0"(0 mm) Mantel Leg Venting Concentric sections of DV Vent 1"(25 mm) Box su ,nd Face -► ' G Non-concentric sections of DV Vent �F Sides and bottom 1"(25 mm) Top 2"(50 mm) K M The height that a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel Side of Combustion Chamber ; leg(if so fitted)and the fireplace. Refer to Fig.4a and Fig.4b, and the Mantel Charts below for the correct mounting height and widths. Mantel The distances and reference points are not affected by Leg the fitting of a bay window front trim kit. Noncombustible mantels and legs may be installed at any height and width around the appliance. To prevent discoloration, use only heat-resistant paint or lacquer to finish the mantel. 11111111111 V CFM164b w Mantel Leg Dimensions (Minimum Width) X Mantel Mantel Leg from Side of Y Ref. Leg Depth Ref. Combustion Opening Z F 10" 254 mm K 11 1/2" 292 mm G 8"(203 mm) L 91/2" 241 mm H 6" 152 mm M 71/2" 191 mm 1 4" 101 mm N 51/2" 140 mm A B C D E J 2"(50 mm) O 31/2"(89 mm) Fireplace Fig.4b Mantel leg dimensions CFM166a Top Louvre Assembly A hearth is not mandatory, but is recommended for Top of Combustion Chamber aesthetic purposes. We recommend using a Bottom of Door Trim noncombustible hearth which projects out 12" CFM146 (305 mm) or more from the front of the fireplace. Mantel Shelf Dimensions(Minimum Height) Cold climate installation recommendation: Mantel Height above When installing this unit against a Ref. Shelf Depth Ref. Firebox noninsulated exterior wall or chase, V 10" 254 mm A 17" 432 mm it is mandatory that the outer walls be W 8"(203 mm) B 15" 381 mm insulated to conform to applicable X 6" 152 mm) C 13"(330 mm) insulation codes. Y 4" 101 mm D 11" 279 mm Z 2"(50 mm) E 9"(229 mm) Fig.4a Combustible mantel leg minimum installation CFM174 10004920 5 Vermont Castings, Majestic Products: DVR33 FinishingFraming and Finishing Final Check fireplace to make sure it is Noncombustible materials such as brick or tile may be levelled and properly positioned. extended over the edges of the face of the appliance. DO NOT cover the window frame assembly,any 1. Choose the unit location. vent, louvre assembly top or louvre assembly 2. Place the unit into position and secure it to the floor bottom. with 1.5"(38 mm)screws, or nails.The holes to If a Trim Kit is going to be installed on the fireplace,the secure the unit to floor are located just behind the brick or tile will have to be installed flush with the edges access door grille on the left and right side of the of the appliance. unit. 3. Frame in the fireplace with a header across the top. It is important to allow for the finished wall face SpecificationsGas when setting the depth of the frame. Max. Min. 4. Attach the fireplace to the frame using the adjustable Input Input frame drywall strips(located behind the access Model Fuel Gas Control BTU/h BTU/h door for shipping). Preset the depth to suit the DVR33RN Nat Millivolt 20,000 14,000 facing material of the wall. The strips are adjustable to 1/2"(13 mm), 5/8"(16 mm),or 3/4"(19 mm). DVR33RP Prop Millivolt 20,000 15,000 (Fig.5) DVR33EN Nat 24 V Hi/Lo 20,000 14,000 5. Screw through the slotted holes in the drywall strip DVR33EP Prop 24 V Hi/Lo i 20,000 15,000 and into predrilled holes in fireplace side. Measure from face of fireplace to the face of the drywall strip to confirm the final depth. Gas Inlet • Manifold Pressures c Adjustable D p Natural LP (Propane) 0 A � Drywall Strip ( P ) (Nailing Flange) Inlet Minimum 5.5"w.c. 11"W.C. B Inlet Maximum 14"w.c. 14"w.c. Screw Drywall Manifold Pressure 3.5"w.c. 10"W.C. 0 Q Position Depths A 1/2" (13 mm) B 5/8" (16 mm) DVR33 C 3/4" (19 mm) CERTIFIED TO ANSI Z21.88-2002/CSA 2.33-2002 Vented Gas Fireplace Heaters Adjustable High Elevations 1/2%5/8-8 o� 3/4"Spacing Input ratings are shown in BTU per • are FP1023 certified without deration for • • to Fig.5 Adjustable drywall strip(nailing flanges). 500 '• For elevations above 4,500 accordanceinstallations must be in and/orcurrent ANSI Z223.1 and/orIn Canada, please consult provincial authorities having jurisdiction for installations at elevations above 00 6 10004920 Vermont Castings, Majestic Products: DVR33 Gas Line Installation Remote ON/OFF Switch Installation When purging the gas lines,the front Do not wire the remote ON/OFF wall Aglass must be removed. switch for this gas appliance into a 120 V power supply. The gas pipeline can be brought in through the side of 1. Thread the wiring through the electrical knockout the fireplace as well as the bottom. Knockouts are located on either side of the unit. Take care not to provided on the bottom behind the valve to allow for the cut the wire or insulation on metal edges. Ensure the gas pipe installation and testing of any gas connection. wire is secured and protected from possible dam- It is most convenient to bring the gas line in from the age. Run one end of the gas control valve and the rear right side of the valve as this allows fan installation other end to the conveniently located wall switch. or removal without disconnecting the gas line. 2. Attach the wire to the ON/OFF switch and install the The gas line connection can be made with properly switch into the receptacle box.Attach the cover plate tinned 3/8"copper tubing, 3/8"rigid pipe or an ap- to the switch. proved flex connector. Since some municipalities have additional local codes, it is always best to consult your 3. Connect the wire to the gas control valve(Fig. 7). local authority and the CSA-B149.1 installation codes. For USA installations consult the current National Fuel Remote Gas Code,ANSI Z223.1. ` ° ON/OFF @) Switch r 1/2"GAS SUPPLY o O IJ� 112"NPTx 1/2"FLARE SHUT-OFF VALVE O c\LL�J 3/8'FLEX LINE O (FROM VALVE) a O a o w584-9 Fig.7 Remote switch wiring diagram for RN or RP models. FP297a Fig.6 Typical gas supply installation. Alternate Switch Location Always check for gas leaks with a mild Asoap and water solution applied with a The remote switch can be installed on either side of the brush no larger than 1"(25 mm).Never access door. Mount the switch to the bracket provided apply soap and water solution with a and screw the bracket to either side of the frame, using spray bottle. Do not use an open flame the prepunched holes(Fig. 8). for leak testing. Do not subject the fireplace valve to test pressures exceeding 1/2 p.s.i.Isolate,or disconnect this and any other gas appliance control from the gas line when pressure testing. The gas control is equipped with a captured screw type pressure test point;therefore, it is not necessary to provide a 1/8"test point up stream of the control. When using copper or flex connector use only ap- proved fittings.Always provide a union when using - black iron pipe so that the gas line can be easily disconnected for burner or fan servicing(Fig.6). See cFM104 the gas specification for pressure details and ratings. Fig.8 Alternate switch location. 10004920 7 Vermont Castings, Majestic Products: DVR33 EB-1 Electrical : . Inside The fireplace,when installed, must be Electrical Box © electrically connected and grounded in Retaining Screw accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code 14 Front of unt © For USA installations,follow the local codes and the national electrical code ANSI/NFPA No. 70. © It is strongly suggested that EB-1 outside Electrical Junction Box wiring be carried out by a licensed electrician. © Ensure that the power to the supply line has been disconnected before commencing this procedure. Ci The E13-1 electrical junction box has been supplied Front of Unit standard with this model to allow for easy installation of an optional fan kit. To connect the E13-1 box to the house electrical supply FP580 follow the steps below. 1. Unscrew the retaining screw from the E13-1 base Fig.9 EB-1 receptacle. plate (Fig. 9), and remove the E13-1 assembly from the fireplace. 2. Remove the front cover of the EB-1 box. 3 Remove the plug socket assembly from the EB-1 box. 4. Feed the supply line in from the outside through the cable clamp (Fig. 9). 5. Connect black wire of the power supply line to the brass screw(polarized) of the socket assembly. 6. Connect the white wire of the power line to the chrome screw of the socket assembly. 7. Connect the ground wire of the supply line to the green screw of the socket assembly. 8. Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the unit to prevent strain on the connections. 9. The E13-1 electrical junction box is now ready to supply power to the FK-12 or FK-24 fan kits, if so fitted. 8 10004920 Vermont a�Castings, M Ma jestic Products: DVR33 Electronic Gas Control Valve This appliance may be fitted with a Honeywell Ignition Module. o O To install the remote On/Off starter switch on electronic ignition units(Fig. 10): 1. Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the w�..�wmo••maa wire or insulation on metal edges. Route the wire w wM w ao w ar wr to a conveniently located receptacle box. 1 2 3 4 5 s a 9 2. Attach the wire to the On/ switch and install the switch into the receptacle box. ., T. 3. Connect the White wire from the wall switch to the Black wire from the transformer, using an approved ° ° wire nut. Connect the Black wire from the wall o ° switch to the Black wire running from the#6 0 ® r O position of the ignition module,also using an p i approved wire nut. ° (S) ° ° ° wwaae wue O �I ° L.�.. 10004083-Fig1 Fig.10 Honeywell Ignition Module. GeneralVentingInformation Your fireplace is approved to be vented either through Do not locate termination hood where excessive snow the side wall, or vertically through the roof. or ice build up may occur. Be sure to check vent • Only venting components specifically approved termination area after snow falls, and clear to prevent and labeled for this fireplace may be used. accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards • Venting terminals shall not be recessed into a wall or vent termination area. siding. Location of Vent Termination • Horizontal venting must be installed on a level plane It is imperative to observe minimum without any incline or decline. clearances(shown on the following There must not be any obstruction such as bushes, page)when locating vent terminations. garden sheds,fences,decks or utility buildings within 24"from the front of the termination hood. 10004920 9 ` Vermont Castings, Majestic Products: DVR33 General,Venting Information Termination Location INSIDE CORNER DETAIL F"G _— m D A- F1-__ N ~N E B Fy a�a B -� =-= ------- 0 Operable Foced f p Closed =__- -_ G .L e3k A J G A 1 I A ©VENT TERMINATION ®AIR SUPPLY INLET Q AREA WHERE TERMINAL IS NOT PERMITTED CFM145a Canadian Installations' US Installations2 A=Clearance above grade,veranda,porch, 12 in.(30 cm) 12 in.(30 cm) deck or balcony B=Clearance to window/door that may be opened 6 in.(15 cm)for appliances<10,000 Btuh 6 in.(15 cm)for appliances<10,000 Btuh (3 kW);12 in(30 cm)for appliances (3 kW);9 in.(23 cm)for appliances >10,000 Btuh(3 kW)and<100,000 Btuh >10,000 Btuh(3 kW)and<50,000 Btuh (30 kW);36 in.(91 cm)for appliances (15 kW);12 in.(30 cm)for appliances >100 000 Btuh 30 k >50 000 Btuh 15 k C=Clearance to permanently closed window 12 in.(305 mm)recommended to 12 in.(305 mm)recommended to prevent window condensation preventwindow condensation D=Vertical clearance to ventilated soffit located above the terminal within a horizontal distance 18 in.(458 mm) 18 in.(458 mm) of 2 ft(610 mm)from the center line of the terminal E=Clearance to unventilated soffit 12 in. 305 mm 12 in. 305 mm F=Clearance to outside comer See next page.) See next e. G=Clearance to inside comer See next e. See next e. H=Clearance to each inside of center line 3 ft(91 cm)within a height of 15 ft(4.57 m) 3 ft(91 cm)within a height of 15 ft(4.57 m) extended above meter/regulator assemblyabove the meter/ ulator asse above the meter/regulator assembly 1= Clearance to service regulator vent outlet 3 ft 91 cm 3 ft. 91 cm J= Clearance to non-mechanical air supply 6 in.(15 cm)for appliances<10,000 Btuh 6 in.(15 cm)for appliances<10,000 Btuh inlet to building or the combustion air inlet (3 kW);12 in.(30 cm)for appliances (3 kW):9 in.(23 cm)for appliances to any other appliance >10,000 Btuh(3 kW)and<100,000 Btuh >10,000 Btuh(3 kW)and<50,000 Btuh (30 kW);36 in(91 cm)for appliances (15 kW);12 in.(30 cm)for appliances >100,000 Btuh 30 >50,000 Btuh 15 k K=Clearance to a mechanical air supply inlet 6 ft.(1.83 m) 3 fit.(91 cm)above if within 10 ft(3.05 m) horizontal) L= Clearance above paved sidewalk or a 7 ft.(2.13 m)t 7 ft(2.13 m)t paved driveway located on public property M=Clearance under veranda,porch,deck or 12 in.(30 cm)t 12 in.(30 cm)t balcony N=Clearance above a roof shall extend a minimum of 24"(610 mm)above the highest point when it passes through the roof surface,and any other obstruction within a horizontal distance of 18"(450 mm). 1 In accordance with current CSA-8149 Installation Codes. 2 In accordance with current ANSI Z223.1/NFPA 54 National Fuel Gas Codes. t A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single-family dwellings, and which serves both dwellings. t Only permitted if veranda/porch/deck is fully open on a of minimum two sides beneath the floor. NOTES: " Local codes or regulations may require different clearances. The special venting system used on Vermont Castings,Majestic Products Direct Vent Fireplaces are certified as part of the appliance,with clearances tested and approved by the listing agency. Fig.11 Vent termination clearances 10 10004920 Vermont Castings, Majestic Products: DVR33 r Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Comer Outside Corner Recessed Location B= D A= Combustible�--- Combustible( ) Noncombustible 6"(152mm) E /1L._ A 6" 152mm JAin V V Noncombustible 2"(50mm) V 2"(50mm) y B r Balcony- Balcony- with no side wall with perpendicular side wall x C=Maximum depth of 48" G H (1219mm)for recessed location. V V D=Minimum width for back wall of a recessed location. Combustible 38"(965mm) Combustible& Noncombustible 24"(610mm) G- Noncombustible Combustible / E=Clearance from corner in Noncombustible H=24"(610mm) recessed location. 12"(305mm) Combustible 6"(152mm) J=20"(508mm) Noncombustible 2"(50mm) CFM115 Fig. 12 Termination clearances. General Information for • • Vent Pipes-- Crimped End Pipes 1"(25 mm)from Before joining elbows and pipes, apply a bead of high crimped end of pipe temperature sealant to the crimped end of the elbow or pipe. I �---- Join the pipes using a 2"(50 mm) overlap and secure the joints with three sheet metal screws (Fig. 13). Wipe off excess sealant. Canadian Installations: Screw �— The venting system must be installed in accordance CFM175 with the current CSA-6149.1 installation code. Fig.13 Apply a bead of high temperature sealant. USA Installations: The venting system must conform to local codes and/ or the current National Fuel Code ANSI Z223.1. Only venting components manufactured by Vermont Castings, Majestic Products may be used in Direct Vent systems. 10004920 11 Vermont Castings, Majestic Products: DVR33 Twist Lock . - When using Vermont Castings,Majestic Products Max.20" twist-lock pipe it is not necessary to use sealant on the (50$mm) joints.The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the fireplace and termination,and the sliding joint of any telescopic vent section used in Top view flat installation the system. To join twist lock pipes together,simply align the beads Max.20" of the male end with the grooves of the female end, (508 mm) twisting the pipe until the flange on the female end contacts external flange on the male end. It is recom- mended that you secure the joints with three(3)sheet metal screws, however this is not mandatory with twist lock pipe(Fig. 14). To make it easier to assemble the joints we suggest putting a lubricant(Vaseline or similar)on the male end of the twist lock pipe prior to assembly. Top view comer installation FP1188 Male End Female End Fig. Rear vent ap plication,pplication,maximum horizontal distance. Rear Wall Vent 0 0 Installation Step 1 Screw Holes Locate and cut the vent opening in the wall. Twu00 For combustible walls first frame in opening(Fig. 16). Fig.14 Twist-Lock pipe joints. Combustible Walls: Cut a 103/e'H x 93/s"W(265 mm x 240 mm)hole through the exterior wall and frame as Rear Wall Vent Application shown. Noncombustible Walls: Hole opening should be 7�/s" When installed as a rear vent unit this appliance may (190 mm)in diameter. be vented directly to a termination located on the rear Zero clearance sleeve Is only required wall behind the appliance for combustible walls. • Only Vermont Castings, Majestic Products vent- ing components are approved to be used in these Step 2 applications(See Venting Components listed for different installation requirements). Measure wall thickness,and cut zero clearance sleeve • The maximum horizontal distance between the rear to proper length;i.e., max. 12"(304.8 mm).Assemble of the appliance(or end of the transition elbow in a sleeve to its maximum opening(103ib"x 93ib")and attach to firestop with#8 sheet metal screws comer application)and the outside face of the rear (supplied). Install firestop assembly(Fig. 17). wall is 20"(508 mm) (Fig. 15). • Only one 45'elbow is allowed in these installations. Step 3 • The minimum clearances between any combustible Measure the horizontal length requirement for the material and the vent pipe sections are: venting including a 2"(50 mm)overlap,i.e.from the Top 2" (50 mm) elbow to the outside wall face plus 2"(50 mm) Sides 1" (25 mm) (Fig. 15). Bottom 1" (25 mm) 12 10004920 Vermont Castings, ]Majestic Products: DVR33 � Vent Opening— ' Combustible Wall Finished Wall (240mm) —93ie"- These ends screwed to These ends appliance should be even 103/s" 1 Vent (254 —j--- -- Termination (framing detail) Vent Opening— Noncombustible Wall 71/2" L _ (190mm) --I -- CFM116 I L-Lo 0 O Fig.16 Vent opening,side wall. FP1005 12' Fig.18 Flat to the wall installation. (304.8 mm1 max. - #8 Screws(2) #8 Screws(2) e Firestop (Side View) CFM135a Fig.17 Zero clearance sleeve. Step 4 Install the 4"(100 mm)vent to the appliance collar and secure with 3 sheetmetal screws. Install the 7" (175 mm)vent pipe to the appliance collar and secure with 3 sheetmetal screws. It is not necessary to seal this connection. If a 45'elbow is being used attach the elbow to the appliance in the same manner then attach the venting to the elbow. It is critical that there is no downward slope away from the appliance when connecting the vent or elbow. Step 5 Guide the venting through the vent hole as you place the appliance in its installed position.Guide the 4" (100 mm)and 7"(175 mm)collars of the vent termination into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination remove and realign the venting at the appliance flue collars(Fig. 18).Attach the termination to the wall as outlined in the instruction sheet supplied with the termination. 10004920 13 = Vermont Castings, Majestic Products: DVR33 GraphHow To Use the Vent . . The Vent Graph should be read in conjunction with the Since it is very important that the venting system following vent installation instructions to determine the maintain its balance between the combustion air relationship between the vertical and horizontal intake and the flue gas exhaust, certain limitations dimensions of the vent system. as to vent configurations apply and must be strictly 1. Determine the height of the center of the horizontal adhered to. vent pipe exiting through the outer wall. Using this The Vent Graph, showing the relationship between dimension on the Sidewall Vent Graph(Fig. 19), locate vertical and horizontal side wall venting, will help to the point intersecting with the slanted graph line. determine the various dimensions allowable. 2. From the point of this intersection, draw a vertical Minimum clearance between vent pipes and com- line to the bottom of the graph. bustible materials is one 1" (25 mm)on top, bottom 3. Select the indicated dimension, and position the and sides unless otherwise noted. fireplace in accordance with same. Example A: When vent termination exits through foundations less If the vertical dimension from the floor of the fire- than 20" (508 mm) below siding outcrop, the vent pipe place is 11' (3.4 m)the horizontal run to the face of must flush up with the siding. the outer wall must not exceed 14' (4.3 m) It is best to locate the fireplace a way that minimizes Example B: the number of offsets and horizontal vent length. If the vertical dimension from the floor of the unit is The horizontal vent run refers to the total length of vent 7' (2.14 m)the horizontal run to the face of the pipe from the flue collar of the fireplace (or the top of outer wall must not exceed 81/2' (2.6 m) the Transition Elbow)to the face of the outer wall. Horizontal plane means no vertical rise exists on this portion of the vent assembly. When installing the appliance as a rear 2e vent unit,the 90"or 45"transition elbow 27 < attached directly to the rear of the unit is 26 0 C NOT INCLUDED in the following criteria zs _1 0 and calculations. Unless this transition 24 m °' elbow is specifically mentioned, it should be ignored when calculating 21 :3 Cl) venting layouts. CT = 20 CD rn 19 :3 18 —i m (3)x 90 degree elbows 17 tp 16 14 N CD 13 o m Min. 7.5' 11 egCD 0 _- 10 7 9 cso 6 � c co e eg. t3 5 4 Max.20'(6.1 m) 3 Kill ] I I I I I I 3 4 5 6 7 6 9 70 1112 1314 1516 1718 19 20 0 Horizontal Dimension From the Outside Face of P0 the Wall to the Center of the Fireplace Vent Flange Fig.20 Maximum three(3)900 elbows per installation. Sidewall Vent Graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system. CFM102 The maximum number of 90' elbows per side wall Fig.19 Sidewall venting graph.(Dimensions in feet.) installation is three (3) (Fig. 20). 14 10004920 Vermont Castings, Majestic Products: DVR33 , As shown in Fig. 22,the total of dimension A and B is Max. 3'(914 mm) not to be greater than 17' (5.2 m). •The maximum number of 45'elbows permitted per side wall installation is two(2). These elbows can � be installed in either the vertical or horizontal run. •For each 45' elbow installed in the horizontal run, "$ the length of the horizontal run MUST be reduced by 18"(45 cm).This does not apply if the 45' elbows are installed on the vertical part of the vent system. •The maximum number of elbow degrees in a system is 270' (Fig. 23). O O O Example: Elbow 1 = 90' - - - - Elbow 2 = 45' Elbow 3 = 45' Fig.21 Maximum horizontal run with no rise. Elbow 4 = 90' • If a 90'elbow is used in the horizontal vent run Total angular variation = 270' (level height maintained),the maximum horizontal 1 +2+3+4=2700 vent length is reduced by 36"(914 mm)(Fig. 22). This does not apply if the 90' elbows are used to Elbow 4 increase or redirect a vertical rise(Fig.20). Example: According to the vent graph(page 14),the Elbow 3 maximum horizontal vent length in a system with a Elbow 2 7.5' (2.3 mm)vertical rise is 20'(6 m),and if a 90' Elbow 1 elbow is required in the horizontal vent, it must be reduced to 17' (5.2 m). "B" "A' 7' 10, (2134 mm) Ignore (3048 mm) t-- Transition Elbow 90•Elbow=3' OoO 7'6' A+B=17'(5.2m)max. (2286 mm) Fig.23 Maximum elbow usage. Redirected vertical rise V584-201 Fig.22 Maximum vent run with elbows. 10004920 15 Vermont Castings, Majestic Products: DVR33 .t Vertical Sidewall Installation Step 1 Locate vent opening on the wall. It may be necessary ----- to first position the fireplace and measure to obtain hole location. Depending on whether the wall is X combustible or noncombustible,cut opening to size. (For combustible walls,frame in opening first(Fig.24). Combustible Walls:Cut a 93/o"H x 93/8"W(240 mm x 240 mm)hole through the exterior wall and frame. Noncombustible Walls: Hole opening must be 71h" (190 mm)in diameter. Vent Opening: Combustible Wall 9 3/8" (241 1 O o O 93/8" —I--- _-- VSW height X (2a0 mm) i Fig.26 Vertical height requirements. Step 3 Framing Detail Place fireplace into position.Measure the vertical Fireplace Hearth height(X) required from the base of the flue collars to Vent opening:Noncombustible Wall the center of the wall opening(Fig.26). 71/2"Dia. } �-- __-- Step 4 (190 mm' j -_i Apply a bead of high temperature silicone sealant to ���--- vosea too the inner and outer flue collars of the fireplace and Fig.24 Locate vent opening on wall. using appropriate length of pipe section(s)attach to fireplace with three(3)screws.Follow with the installa- 1r bon of the inner and outer elbow,again secure joints tax m) as described in the'Connecting Vent Pipe'section. ----Z Step 5 #a Screws(2) Measure the horizontal length requirement including a ----tea 2"(50 mm)overlap, i.e.from the elbow to the outside #8 Screws(2) " wall face plus 2"(50 mm)—or the distance required if a�----- installing a second 90'elbow(Fig.27). Always install horizontal venting on Firestop (sidev.) CFM135a a level plane. Fig.25 Adjustable zero clearance sleeve. Step 6 Zero clearance sleeve is required only Use the appropriate length of pipe sections—telescopic for combustible walls. or fixed—and install.The sections which go through the wall are packaged with the starter kit,and can be cut to suit if necessary. Step 2 NOTE: Sealingpipe and firestop vent P�P P gaps with Measure wall thickness and cut zero clearance sleeve high temperature sealant will restrict cold parts to proper length(12"[305 mm]max.).Assemble air being drawn in around fireplace. sleeve and attach to firestop with#8 sheetmetal screws(supplied). Install firestop assembly(Fig.25). 16 10004920 Vermont Castings, Majestic Products: DVR33 s High Temperature X If installing a snorkel,a minimum 24"(610 mm)vertical Sealant rise is necessary.The maximum horizontal run with the 24" (610 mm)vertical pipe is 36" (915 mm).This measurement is taken from the collar of the fireplace (or transition elbow)to the face of the exterior wall. _____ See the Sidewall Venting Graph for extended ----- horizontal run if the vertical exceeds 24" (610 mm). 1. Establish vent hole through the wall (Fig.24, page 16). 2. Remove soil to a depth of approximately 16" (406 mm)below base of snorkel. Install drain pipe. Install window well(not supplied). Refill hole with 12"(305 mm)of coarse gravel leaving a clearance of approximately 4"(100 mm) below snorkel (Fig. 28). 3. Install vent system. L 4. Ensure a watertight seal is made around the vent CFM137 pipe coming through the wall. Fig.27 Horizontal length requirement. 5. Apply high temperature sealant caulking (supplied) Step 7 around the 4"and 7"snorkel collars. 6. Slide the snorkel into the vent pipes and secure to Apply high temperature sealant to 4"(100 mm)and 7" the wall. (175 mm)collars or the termination one inch away from 7. Level the soil so as to maintain a 4"clearance crimped end. Guide the vent terminations 4"and 7" (100 mm)below snorkel(Fig. 28). collars into their respective vent pipes. Double check that the vent pipes overlap the collars by 2" (50 mm). Secure the termination to the wall with screws provided zero clearance Sleeve, and caulk around the wall plate to weatherproof. itreqB"e _ 7DVSKS f— snorkel) As an alternative to screwing the termination directly to Fkestop strewn the wall,you may also use expanding plugs or an rp�pe—� -- i cio2�mm) approved exterior construction adhesive. Or, you may Ground attach the termination with screws through the inner tvr•,dow body into the 4"vent pipe—however,for this method, f 0 000 wet you must extend the 4"pipe approximately 6" 24"(W8mm) `� c�G G<ava (150 mm) beyond the outer face of the wall. min.. Support horizontal pipes every 3' D (91 cm)with metal pipe straps. rain Foundation wan Minin um 24"(609 mm) Below •e Installation vertical pipe must be installed When it is not possible to meet the required vent terminal .190.0.1 when using 7DVSKS Kd. clearances of 12"(305 mm)above grade level,a Snorkel CFM193 Vent Kit#7DVSKS is recommended. It allows installation Fig.28 Below grade installation. depth down to 7"(178 mm)below grade level.The 7" (178 mm)is measured from the center of the horizontal Do not backfill around snorkel, vent pipe as it penetrates through the wall. A clearance of at least 4"(102 mm)must NOTE: Ensure that sidewall venting clearances be maintained between the snorkel and are observed. If the venting system is the soil. installed below ground,we recommend a window well with adequate and proper drainage to be installed around the termination area. 10004920 17 Vermont Castings, Majestic Products: DVR33 If the foundation is recessed, use recess brackets(not Up to two 450 elbows may be used within the supplied)for securing lower portion of the snorkel. horizontal run. For each 450 elbow used on the Fasten brackets to wall first,then secure to snorkel with horizontal plane,the maximum horizontal length self drilling#8 x 1/2 sheet metal screws.It will be must be reduced by 18"(450 mm). necessary to extend vent pipes out as far as the Example: Maximum horizontal length protruding wall face(Fig.29). No elbows = 10'(3 m) 1 x 45°elbows = 8.5'(2.6 m) 2 x 450 elbows = 7'(2.1 m) • A minimum of an 8'(2.5 m)vertical rise is required. Snorkel • Two sets of 450 elbows offsets may be used within Foundation f the vertical sections.From 0 to a maximum of 8' Recess (2.5 m)of vent pipe can be used between elbows 4 Wall screws (Fig.30). • 7DVCS supports offsets(Fig.32).This application will require that you first determine the roof pitch Watrtight Sheetmetal screws and use the appropriate starter kit. (See Venting Seal Around Components List). Seal A Pipe • The maximum angular variation allowed in the CFM139 system is 2700(Fig.31). Fig.29 Snorkel installation,recessed foundation. • The minimum height of the vent above the highest point of penetration through the roof is 2'(610 mm) (Fig.33). Vertical . Applications This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m)in height.Up to ,. a 10'(3 m)horizontal vent run can be installed within the vent system using a maximum of two 900 elbows (Fig.30). F, 45 degree elbows , >- Maximum 8'(2.5m) Y Max.40'(12 m) Min.7.5'(2.3 m) t 4i . 10001 t TTR-max45 -t i Fig.31 Maximum elbow usage. I Max.10'(3.1 m) j i E si O-0 TTR max dim Fig.30 Support straps for horizontal runs. 18 10004920 Vermont Castings, Majestic Products: DVR33 I Vertical Through-the-Roof Installation Typical Ceiling 1.Locate your fireplace. Support 2.Plumb to center of the(4")flue collar from ceiling Typical Application above and mark position. Roof 3.Cut opening equal to 93/8"x 9%"(240 mm x Support .• \ 240 mm). Application 4.Proceed to plumb for additional openings through the roof. In all cases,the opening must provide a minimum of 1 inch clearance to the vent pipe,i.e., FP1184 the hole must be at least 9%"x 93/81 (240 mm x Fig.32 Venting supports. 240 mm). 5.Place fireplace into position. 6.Place firestop(s)#7DVFS or Attic Insulation Shield ; #7DVAIS into position and secure(Fig.32 . t, Min. P ( g i N a` 2'(610 mm) 7.Install roof support(Fig.33)and roof flashing, making sure upper flange is below the shingles (Fig.34). r,;":-" 8.Install appropriate pipe sections until the venting is f '=„ above the flashing (Fig.34). 9.Install storm collar and seal around the pipe. 10.Add additional vent lengths for proper height (Fig.33). 11.Apply high temperature sealant to 4"and 7"collars FP1189 of vertical vent termination and install. Fig.33 Minimum termination to roof clearance. If a room is above ceiling level,a firestop spacer must be installed on each level (top and bottom)of the ceiling joists. If an attic is above ceiling level,a 7DVAIS (3)#5 (Attic Insulation Shield)must be Sheet Metal installed.Always face the enlarged ends (3)he t Metal pe ews r Joint of the vent section downward. Screws jper Joint Sealant Storm Attic Insulation , c Sealant Collar Storm Shield Collar TWL101a Upper Floor Fig.34 Roof flashing. 1 ll Ceiling Installation Joist D , 1 j Firestop Spacer Nails(4) FP1029 Fig.32 Attic insulation shield and firestop spacer. 10004920 19 Vermont Castings, Majestic Products: DVR33 W • DVR33 • estricter Installation NOTES: When installing DVR33 with a vertical through-the-roof configured flue system, e the bracket restricter supplied with the appliance(part#10002910)should be e fitted to the appliance at installation. 1 For DVR33 numbers Al2H00,A12100, A14A00 and A14B00 only,the restricter plate for the vertical termination(part# 10003246)must be installed for vertical runs over 20'(6.1 m). Fitting the Bracket Restricter Fig.36 Top face of baffle assembly 1.Remove the window glass/frame assembly. Locate the baffle firebox assembly in the top rear of the firebox(Fig. 35). 2.Remove the four(4) nuts along the front edge, and the three(3) screws along the rear edge of the baffle assembly. Remove the baffle assembly from the firebox. i 3.Remove the two(2)screws from the top face of the baffle assembly(Fig. 36). Place the bracket restricter as it is shown in Fig. 37,and secure it by - refitting the screws. 4.Refit the baffle assembly to the firebox, replacing the three(3)screws and four(4)nuts. 5.Refit window glass/frame per the appropriate Fig.37 Assembling bracket restricter to baffle assembly sections. 0 0 0 000 . o Baffle firebox assembly Fig.35 Baffle firebox assembly 20 10004920 Vermont Castings, Majestic Products: DVR33 Twist Lock Venting Components 7DVRVT-Through-the-Wall Rear Vent Termination Starter Kit-Model 7TDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting r for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDSKV-F order flat roof ~^ Starter Kit-Model 7TDVSKS-Snorkel Kit for Below Grade Installation 45'elbow kit 7TDVT45 for Vertical Installation Offsets 7TDR45 for Rear Vent Application 90'Transition elbow kit 7TDVRT90 for Vertical Sidewall Applications or through-the-roof. Telescopic vent sections ------------ ----------- 7TDVP1218 -12"to 18"adjustable length 7TDVP3564 -35"to 64"adjustable length Pipe sections for vertical or horizontal venting Model 7TDVP8" 4 per box - ------- ----------------- Model 7TDVP 12" 4 per box ------------------------ Model 7TDVP24" 4 per box Model 7TDVP36" Model 7TDVP48" Firestop Spacer Model7DVFS Attic Insulation Shield Model 7DVAIS Vertical/Horizontal Combination Offset Support Model 7DVC 10004920 21 -� Vermont Castings, Majestic Products: DVR33 Crimped End Venting Components 7DVRVT-Through the wall Rear Vent Termination Starter Kit-Model 7DVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting r for 7DVSKV-A order 1/12 to 6/12 roof pitch for 70VSKV-B order 7/12 to 12/12 roof pitch for 7DSKV-F order flat roof —�^ Starter Kit-Model 7TDVSKS-Snorkel Kit for Below Grade Installation 45"elbow kit 7DVT45 for Vertical Installation Offsets 7DV45 for Rear Vent Application 90'Transition elbow kit 7DVRT90 for Vertical Sidewall Applications or through-the-roof. Telescopic vent sections 7DVP610- 6"to 10"adjustable length 7DVP1018- 10"to 18"adjustable length 7DVP1834- 18"to 34'adjustable length 7DVP3466- 34"to 66'adjustable length Pipe sections for vertical or horizontal venting _ Model 7DVP8" 4 per box Model 7DVP12" 4 per box Model 7DVP24" 4 per box Model 7DVP36" Model 7DVP48" Frestop Spacer Model 7DVFS Attic Insulation Shield Model 7DVAIS Vertical/Horizontal Combination Offset Support Model 7DVCS 22 10004920 Vermont Castings, Majestic Products: DVIZ33 R Operating Instructions InformationGlass 6.Tilt window frame assembly out slightly at the bottom, lift the frame up and away from the Use only glass approved by Vermont fireplace. Castings, Majestic Products on this 7.To replace window frame assembly, reverse this fireplace. procedure. •The use of any non-approved replacement glass will void all product warranties. •Care must be taken to avoid breakage of the glass. •Under no circumstances should this appliance be operated without the front glass in place, or with the glass in a damaged condition. •Replacement glass(complete with gasket)is available through your Vermont Castings, Majestic Lower Products dealer, and should only be installed by a Clamps licensed qualified service person. window Frame Assembly • - - • window _ "1. Frame r-= To remove the louvre assembly top, lift the panel up ii�Assebl ' ' ` ull Clamp Hook and out from the fireplace(Fig. 38). i'i Push Clamp NOTE: The louvre assembly bottom is hinged at Handle the bottom edge and swings down. FP1191 Fig.39 Window frame assembly removal. 2.—0- CleaningGlass It is necessary to periodically clean the glass panel. f Louvre Assembly Top During start-up, it is normal for condensation to form 1. on the inside of the panel. This condensation causes 1 lint,dust and other airborne particles to cling to the surface of the glass. Also, initial paint curing may deposit a slight film on the Window Frame Assembly glass. It is therefore recommended the glass panel be cleaned two or three times with a non-ammonia-based FP444 household cleaner and warm water within the first few Fig.38 Remove louvre assembly top. weeks of operation. We recommend using gas fireplace glass cleaner. FrameWinow Removal After the initial cleaning process, clean the glass two or • three times during each operating season,depending 1.Turn the fireplace OFF (including the pilot). on the environment in the house. 2.If the unit has been operating, allow time for the Clean the glass after the first two weeks components to cool. of operation. 3.Remove the louvre assembly top. Do not clean glass when it is hot. 4.Open the louvre assembly bottom. Do not use abrasive cleaners. 5. Release the two clamps along lower edge of the Do not strike or slam the glass. frame by pulling down on clamp handles(Fig. 39). 10004920 Z3 A Vermont Castings, Majestic Products: DVR33 Installation of Logs Lava Rock: (Part Number 10001454) Remove from packaging and spread over the sides of the burner ' LavaRock Materialhousing. Do not place this material on the burner The logs are fragile and should be tiles. handled with care. Keep the packaging material out of the reach of children, and dispose of the material in a safe manner. During this procedure, refer to Fig. 40 for log + rro^ identification. " 1. Remove the top louvre assembly. 2. Remove the window frame assembly. See"Window " Frame Assembly Removal" on page 23. 3. Fit the rear right log (A34) in place on the rear log Fig.41 DVR33 Log Set Assembly. support. The hole in the underside of the log fits NOTE: Glowing lava rock for DVR33 is only over the pin on the right end of the support shelf. allowed to be positioned at the front area 4. Fit the front/rear left log (A33) in place on the rear (radiant portion)of the burner housing log support. The hole in the underside of the log fits assembly. over the pin on the left end of the support shelf. 5. Fit the front right log (A35) in place, the top end of Flame and Temperature Adjustment the log with the hole in the underside aligning with the knob on the rear right log (A34), and the other RN/RP and EN/EP Models end with the cut slot resting on the right side edge For units equipped with 'HI/LO' valves the flame of the front grate. adjustment is accomplished by rotating the 'HI/LO' 6. Fit the front center log (A36) on the center slot of adjustments knob located near the center of the gas the front grate. The flat end of this log sets against control valve (Fig. 41 and Fig. 42). the back wall of the front grate plate. i Turn Turn clockwise counterclockwise to increase to decrease ec ease A33 _ A34 flame height , flame height �I A35 Honeywell Valve Honey well Fig.41 Flame adjustment knob for Honeywell Valve. A36 Fig.40 DVR33 Log Set(top view) The log set contains two types of lava rocks. Placing Turn counterclockwise Turn clockwise these materials is best done after the logs have been to decrease to increase installed. flame height flame height Glowing Lava Rock: (Part Number 57897) Remove from the packaging and spread them over the burner SIT Valve Nova820 tiles in a random fashion to fill the space highlighted in Fig 41. Fig.42 Flame adjustment knob for SIT Valve. 24 10004920 Vermont Castings, Majestic Products: DVR33 , ' I Flame Characteristics v Y- • • the Venting System It is important to periodically perform a visual check of This appliance venting system is designed and the pilot and burner flames. Compare them to the constructed to develop a positive flow adequate to pictorials illustrated below(Fig. 43 and Fig. 44). If the remove flow gases to the outside atmosphere. flame patterns appear abnormal, contact a qualified Any foreign objects in the venting system,except those service provider for service and adjustment. designed specifically for the venting system, may cause spillage of flue gases. 3/8 1/2 To inspect the venting system, make sure the main gas valve is off. Remove the window frame assembly SIT Pilot RN/RP (Refer to Window Frame Assembly Removal section). Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary. Pilot SIT 0 0 o Q PSE Pilot RN/RP SIT Pilot EN/EP SIT pilot CFM181 Fig.43 Correct pilot flame appearance. gown } I I �o Fig.44 Correct burner flame appearance. 10004920 �, Vermont Castings, Majestic Products: DVR33 Lighting andOperating Instructions FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- If you cannot reach your gas supplier,call ally.When lighting the pilot follow these instruc- the Fire Department. tions exactly. C. Use only your hand to push in or turn the gas B. BEFORE LIGHTING smell all around the heater control knob. Never use tools. If the knob will not area for gas. Be sure to smell next to the floor push in or turn by hand,do not try to repair it,call a because some gas is heavier than air and will qualified service technician.Applying force or any settle on the floor. attempted repair may result in a fire or explosion. WHAT TO DO IF YOU SMELL GAS D. Do not use this fireplace if any part has been under • Do not try to light any fireplace. • Do not touch any electric switch. water. Immediately call a qualified service techni- • Do not use any phone in your building. clan to inspect the heater and to replace any part of • Immediately call your gas supplier from a the control system and any gas control which has neighbor's phone. Follow the gas supplier's been underwater. instructions. Lighting Instructions 1. STOPI Read the safety information above. 10. Push the control knob all the way in and hold. 2. Turn off all electrical power to the fireplace. Immediately light the pilot by repeatedly depressing 3. For MN/MP/TN/TP appliances ONLY,go on to the piezo spark igniter until a flame appears. Step 4. For RN/RP appliances turn the On/Off Continue to hold the control knob in for about one switch to"OFF"position or set thermostat to (1)minute after the pilot is lit. Release knob and it lowest level. will pop back up. Pilot should remain lit. If it goes 4. Open control access panel. out, repeat steps 5 through 8. 5. Push in gas control knob slightly and turn If knob does not pop up when released,stop clockwise to"OFF". and immediately call your service technician or ,T pp gas supplier. C O 2 T �S 6 -70 Euro SIT SIT NOVA Honeywell 6. Wait five(5)minutes to clear out any gas.Then smell for gas, including near the floor. If you If after several tries,the pilot will not stay lit,turn smell gas,STOP! Follow"B"in the safety the gas control knob to"OFF"and call your information above. If you do not smell gas,go to service technician or gas supplier. the next step. 11. Replace glass door. 7. Remove glass door before lighting pilot.(See 12.Turn gas control knob to"ON"position. Glass Frame Removal section). 13. For RN/RP appliances turn the On/Off switch to 8. Visibly locate pilot by the main burner. "ON"position or set thermostat to desired setting. 9. Turn knob on gas control counter-clockwise to"PILOT". 14.Turn on all electrical power to the fireplace. To Turn Off Gas To Heater 1. Turn the On/Off switch to Off position or set the 3. Open louvre assembly bottom. thermostat to lowest setting. 4. Push in gas control knob slightly and turn 2. Turn off all electric power to the fireplace if clockwise /—ti to"OFF". Do not force. service is to be performed. 5. Close control access panel. 26 10004920 Vermont Castings, Majestic Products: DVR33 ` r Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly,a fire or explosion may result causing property damage,personal injury and loss of life. Emir For • . • the following warnings before lighting the appliance: A. This fireplace is equipped with an ignition device If you cannot contact your gas supplier call which automatically lights the pilot. DO NOT try to the Fire Department light the pilot by hand. C. Use only your hand to push in or turn the gas B. BEFORE OPERATING,smell all around the control knob. Never use tools. If the knob will not appliance area for gas. Be sure to smell next to push in or turn by hand do not try to repair it,call a the floor because some gas is heavier than the air qualified service technician. Force or attempting and will settle on the floor. repair may result in a fire or explosion. What to do if you smell gas D. Do not use this appliance if any part has been • Do not try to light any appliance under water. Immediately call a qualified service • Do not operate any electrical switch. technician to inspect the appliance and replace • Do not use any phone in your building. any part of the control system and any gas control • Immediately call your gas supplier from a that has been under water. neighbor's phone. Follow the gas suppliers instructions. Emir Lighting Instructions 1. STOPI Read the safety information above before 5. Turn the remote switch, if used, OFF. Turn the continuing. wireless remote, if used,OFF. 2. Turn off all electrical power to the appliance. 6. Wait five(5)minutes to clear out any gas.Then 3. This appliance is equipped with an ignition device smell for gas, including near the floor. If you smell which automatically lights the pilot. DO NOT try to gas STOP. Follow instructions B in the safety light the pilot by hand. warnings above. If you do not smell gas go onto the 4. Access the gas control by lowering the lower next step. access door(louvre assembly). 7. Close the access door. 8. Turn ON all electrical power to the appliance. (S) @0 9. Turn remote switch or wireless remote to ON. 0 O I 10. If the appliance will not operate,follow the o O instructions"Turning Off the Gas to the Appliance" [:L�@ N I (below), and call your service technician or gas � 0 supplier. 0 0 Turning Off the Gas to the Appliance 1. Turn the remote switch to the"OFF"position. 12-GAS SUPPLY 2. Turn OFF all electrical power to the fireplace if jr 12'NPTx 12'FLARE SHUT-OFF VALVE service is required. • 3/8'FLEX LINE 3 Open the lower access panel. (FROM VALVE) 4. Turn the shut-off valve on the flexible gas line to NOTE: Shut-off valve the"OFF"position. is shown in"ON"position 10004920 27 J Vermont Castings, Majestic Products: DVR33 Troubleshooting Control System SIT NOVA 820 MILLIVOLT VALVE Note: Before trouble shooting the gas control system,be sure external gas shut off is in the"On"position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1.Spark ignitor will not light A.Defective or misaligned Using a match,light pilot.If pilot lights,turn off electrode at pilot. pilot and push the red button again.If pilot des not light,check gap at electrode and pilot;it should be 1/8"to have a strong spark. B. Defective ignitor(Push Button) Push Piezo Ignitor Button.Check for spark at electrode and pilot.If no spark to pilot,and elec trode wire is properly connected,replace ignitor. 2.Pilot will not stay lit after A. Defective pilot generator Check pilot flame. Must impinge on thermo carefully following lighting (thermocouple),remote wall coupletthermopile. Note:this pilot burner assem instructions. switch. bly utilizes both-a thermocouple and a thermopile. The thermocouple operates the main valve operation(On and Off).Clean and or adjust pilot for maximum flame impingement on thermopile and thermocouple. B.Defective automatic valve Turn valve knob to"Pilot". Maintain flow to pilot; millivolt meter should read greater than 10 mV. If the reading is okay and the pilot does not stay on, replace the gas valve. Note: An interrupter block (not supplied)must be used to conduct this test. 3.Pilot burning,no gas to A.Wall switch or wires defective Check wall switch and wires for proper connec main bumer tions.Jumper wire across terminals at wall switch,if bumer comes on,replace defective wall switch.If okay,jumper wires across wall switch wires at valve,if burner comes on,wires are faulty or connections are bad. B.Thermopile may not be 1.Be sure wire connections from thermopile at generating sufficient gas valve terminals are tight and thermopile is millivoltage. fully inserted into pilot bracket. 2.One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals if pilot now stays lit,trace wall switch wiring for ground.May be grounded to fireplace or gas supply. 3.Check thermopile with millivolt meter.Take reading at thermopile terminals of gas valve. Should read 250-300 millivolts(minimum 150) while holding valve knob depressed in pilot position and wall switch"Off". Replace faulty thermopile if reading is below specified minimum. C.Plugged burner orifice. Check burner orifices for debris and remove. D.Defective automatic valve Turn valve knob to"On",place wall switch to"On" operator. millivolt meter should read greater than 100 mV. If the reading is okay and the burner does not come on,replace the gas valve. 4.Frequent pilot outage A. Pilot flame may be too low Clean and/or adjust pilot flame for maximum flame problem. or blowing(high)causing the impingement on thermopile and thermocouple. pilot safety to drop out. B. Possible blockage of the vent Check the vent terminal for blockage(recycling the terminal. flue gases) 10004920 29 Vermont Castings, Majestic Products: DVR33 r Troubleshooting Control System SIT 822 Valve with a Honeywell Electronic Igniter START NOTE: Remove glass before servicing. •TURN GAS SUPPLY OFF NO CHECK: •LINE VOLTAGE(120VAC) •TURN ON/OFF SWITCH •LOW VOLTAGE TRANSFORMER TO CALL FOR HEAT (19.5 minimum VAC) •ON/OFF SWITCH POWERTO MODULE •WIRING CONNECTIONS (24V NORMAL) YES UNPLUG IGNITION LEAD NO AND CHECK SPARK • REPLACE MODULE APRK ACROSS NO AT MODULE IGNITOR SENSOR GAP (24VAC normal) YES SPARK OK? YES • CHECK IGNITION CABLE GROUND WIRING,CERAMIC INSULATOR AND GAP. CORRECT AS NECESSARY • CHECK BOOT OF IGNITION CABLE FOR SIGNS OF MELING OR BUCKLING.TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BOOT FROM EXCESSIVE TEMPERATURES. • TURN GAS ON NO, • CHECK THAT ALL MANUAL GAS VALVES ARE OPEN,SUPPLY TUBING PILOT BURNER LIGHTS? AND PRESSURES ARE GOOD,AND PILOT BURNER ORIFICE IS NOT BLOCKED. YES • CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OEPRATOR ON GAS CONTROL • CHECK FOR 24VAC ACROSS PV-MVPV TERMIANLS ON MODULE IF VOLTAGE IS OKAY,REPLACE GAS CONTROL IF NOT,REPLACE IF MODULE. SPARK STOPS WHEN NO NOTE: IF S8600B GOES INTO LOCKOUT,RESET SYSTEM. PILOT IS LIT? • CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE. YES • CLEAN FLAME ROD. • CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROAD&MODULE. • CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR. • CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR. • CHECKTHAT PILOT FLAME COVERS FLAME ROD AND IS STEADY BLUE • ADJUST PILOT FLAME. • IF PROBLEM PERSISTS,REPLACE MODULE. NO • CHECK FOR 24VAC ACROSS MV MVPVTERMINALS IF NO MAIN BURNER UGHTS? VOLTAGE,REPLACE MODULE. • CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS YES CONTROL IF OKAY,REPLACE GAS CONTROL,OR GAS CONTROL OPERATOR. SYSTEM RUNS UNTIL NO NOTE: IF S8600B GOES INTO LOCKOUT,RESET SYSTEM. ON/OFF SWITCH IS IN "OFF"POSITION • CHECK FOR CONTINUITY OF IGNITION CABLE AND GROUND WIRE. YES NOTE:IF GROUND IS POOR OR ERRATIC,SHUTDOWN MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL ATTHETIME OF CHECKOUT. • CHECK THAT THE PILOT FLAME COVERS FLAME ROAD AND IS STEADY TROUBLESHOOTING AND BLUE. ENDS • IF CHECKS ARE OKAY,REPLACE MODULE 30 10004920 Vermont Castings, Majestic Products: DVR33 A Fuel Conversion Instructions Honeywell Gas Control Valve(Fig.48): The Honeywell valve fitted to this unit is suitable For RN and RP models only: for use with LP or Natural Gas. It is converted to the required gas application by installation of a The conversion of this appliance from color coded"conversion screw." one gas to another must be carried out a) Using a suitable small screwdriver lift out the by an authorized service provider. central regulator cap from the"Hi—Lo"knob on 1. Disconnect power to unit and shut off the gas supply. the valve. 2. Remove the glass(see"Window Frame Assembly b) Unscrew the exposed conversion screw. Removal"section). c) Insert the new color coded conversion screw. 3. Carefully remove the logs and lava rock material. Do not over-tighten the screw, it must be 4. Remove the pilot assembly from the bracket. finger tight. 5. Remove the screws that are holding the burner d) Refit the regulator cap. housing assembly in place. e) Mount conversion label supplied with con- 6. Remove the burner housing assembly. version screw to valve in a visible position. 7. Remove front and rear orifice and replace with the 10. Reassemble fireplace in the reverse order,except orifice supplied in the conversion kit. Use the window frame assembly. Leave this off until after orifice with the smallest hole for the front burner unit has been checked for leaks and the gas and the orifice with the largest hole for the rear supply has been bled. burner. 11.After bleeding gas line and checking for leaks with NOTE: On the DVRT43(only),the adjustable air a soap solution, replace the front glass. Fire up the shutter on the end burner housing must unit, check for flame impingement on logs,adjust- be replaced.Refer to the instructions in ing them if necessary. Check manifold and supply the specific gas conversion kit for pressures against the appliance specifications. details. The procedure for converting from one 8. SIT Top Convertible Pilot gas to another is the same regardless of Gently lift off pilot hood from the pilot. (Do not the initial gas used.The only variations remove the spring clip holding the hood in place). are in orifice sizes and component part Using a 5/32"Allen key,unscrew the exposed orifice. numbers.Your authorized service Insert the new orifice supplied in the kit,do not over provider will ensure correct parts are tighten the orifice.Replace the pilot hood ensuring used. the index tab aligns with the notch on the hood. PSE Pilot Using a suitable wrench on the hexagonal body e unscrew the pilot hood assembly from the pilot; do not twist the hood itself. Remove the orifice and replace it with the new orifice supplied in the kit. C I Refit the pilot hood assembly. Do not overtighten • the pilot hood.The hood must return to its original alignment.Take care to not damage the thermocouple,thermopile, or igniter. 9. SIT 820 NOVA Gas Control Valve(Fig.47): a) Using a Torx T20 or slotted screwdriver, remove i and save three(3)pressure regulator mounting screws(A), pressure regulator tower(B),and diaphram(C). :® b) Ensure the rubber gasket(D) is properly positioned and install the new Hi/Lo pressure Nova SIT820 Gas Valve regulator to valve, using the new screws(E) C0122 supplied with the kit. Tighten screws securely. Fig.47 Nova SIT 820 gas valve conversion. (Reference torque:25 in.lb) c) Install the enclosed identification label (F)to the valve body where it can be easily seen. 10004920 31 Vermont Castings, Majestic Products: DVR33 Cleaning the . —Regulator Cap St anding pilot Control System The burner and control system consists of: Conversion Screw • burner tube •gas orifice • pilot assembly •thermopile • millivolt gas valve Pressure Most of these components may require only an Regulator occasional checkup and cleaning and some may Housing require adjustment. If repair is necessary,it should be performed by a qualified technician. 1. Turn off pilot light at gas valve side. 2. Let fireplace cool if it has been running. 3. Remove window frame assembly. (Refer to Window Frame Assembly Removal section) • 4. Remove logs. 5. Vacuum burner compartment especially around orifice primary air openings. 6. Visually inspect pilot. Brush or blow away any dust or lint accumulation. Honeywell Gas Valve C0123 7 Reinstall logs. Fig.48 Honeywell gas valve conversion. 8. Ignite pilot; refer to Lighting Instructions. 9. Reinstall window frame assembly. General Maintenance To obtain proper operation,it is imperative that the r and Burner Compartment pilot and burner's flame characteristics are steady,not Bume lifting or floating. It is important to keep the burner and the burner compartment clean.At least once per year the and bepenglulfeden the pilot flame(Fig 45, pagel25)should and lava rock/ember material should be removed , qualified the burner compartment vacuumed and wiped out. To adjust pilot burner(to be done by a Remove and replace the logs as per the instructions in service technician): cap. 1. Remove pilot adjustmentp this manual. me. Always handle the logs with care as they 2. Adjust pilot screw to provide properly sized flame. Aare fragile and may also be hot if the 3. Replace pilot adjustment cap. fireplace has been in use. The primary air shutter is set at factory and should be FK241FK12 Fan Assembly adjusted, if necessary, only by a qualified service The fan unit requires periodic cleaning.At least once technician. per month in the operating season,open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint. Brass Trim Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or household cleaners on any brass components. Contact your local representative to arrange an annual service program. 10004920 32 Vermont Castings, Majestic Products: DVR33 / 8 12 1a ,. 1b 11 9 2 2a Y 6 1d 1c 17 3a/b 4alb 5a/b 8 23 O o p f 6 13 14 10 11 / 37 35 16 r R 33 IZ 7 31 32 e + >34 18 c e j 38 26 36 � 22alb 20aVb 15 21 a/b 0 0 e O A & ® ® ® U o a x ! f o O O ,p o I� O � o O� o hl C. e ® • O c 4920 DVR33 parts Vermont Castings,Majestic Products reserves the right to make changes in design,materials,specifications,prices and discontinue colors and products at any time,without notice. DVR33 10004920 33 Vermont Castings, Majestic Products: DVR33 f 40 /39 41 / 19 30 42 O 28 24 Y7 O O � 0 25 0)-29 4920 DVR33 parts2 Vermont Castings,Majestic Products reserves the right to make changes in design,materials,specifications,prices and discontinue colors and products at any time,without notice. DVR33 (Items marked with `"are not shown in the parts illustration.) _Ref. Description DVR33 1. Log Set(complete) 10004921 1a. Log-Front/Rear Left 10004929(A33) 1b. Log-Rear Right 10004925 (A34) 1 c. Log-Front Right 10004928 (A35) 1d. Log-Front Center 10004927 (A36) Lava Rock 1 Ib.package 10001454 Lava Rock Burner Package 57897 2. Burner Housing Assembly, NG&LP 10004901 2a. Ceramic Tile(Single) 57803 • Orifice Bumer NG and LP See the rating plate for orifice specifications 34 10004920 Vermont Castings, Majestic Products: DVR33 DVR33 (continued) (Items marked-are not shown in the parts illustration.) Ref. Description DVR33 3a. Pilot Assembly SIT Top Convertible RN 10002264 3b. Pilot Assembly SIT Top Convertible RP 10002265 4a. Pilot Assembly SIT Top Convertible EN 10002387 4b. Pilot Assembly SIT Top Convertible EP 10002388 v 5a. Pilot Assembly PSE RN 10001741 5b. Pilot Assembly PSE RP 10001742 6. Pilot SIT Top Convertible 10002266 7. Pilot PSE(with Cable and Electrode) 10001824 * Pilot Orifice SIT NG 10002268 ' Pilot Orifice SIT LP 10002269 • Pilot Orifice PSE NG 10001822 * Pilot Orifice PSE LP 10001823 8. Pilot Hood SIT Top Convertible 10002385 9. Thermocouple SIT 53373 10. Thermocouple PSE 10001825 11. Thermopile 51827 12. Ignitor Electrode with Cable,SIT RN/RP 10001297 13. Ignitor Electrode SIT EN/EP 52465 14. Cable Ignitor SIT EN/EP 10000696 15. Piezo Ignitor Honeywell Gas Valve 20000062 16. Piezo Ignitor SIT820 Gas Valve 52464 17. Pilot Tube with Fittings SIT 10001296 18. Pilot Tube with Fittings PSE 10003279 ' Manifold Tube with Fittings 57318 19. Flexible Gas Line with ON/OFF Valve 20002500 20a. Honeywell Gas Control Valve, RN 10001782 20b. Honeywell Gas Control Valve, RP 10001759 21a. SIT820 Gas Control Valve RN 52677 21b. SIT820 Gas Control Valve RP 52678 22a. SIT822 Gas Control Valve EN 57884 22b. SIT822 Gas Control Valve EP 57883 23. Sensing Electrode(w/Cable)EN/EP 57885 24. Transformer 24V EN/EP 7522409 25. Ignition Module Honeywell EN/EP 20000005 • Wire Hamess Honeywell EN/EP 10001979 • Fan Assy(FK-24 option) ZA1100 26. Fan with Bracket(from FK-24 Option) 54103 * Electric Cord(from FK-24 Option) 51865 27. Fan Temperature Sensor(from FK-24 Option) 51704 28. Fan Speed Control(from FK-24 Option) 51738 29. Knob Fan Speed Control(from FK-24 Option) 51882 30. Sensor w/Box and Wire(from FK-24 Option) 10004210 * Fan Assembly(FK-12 Option) ZA1110 31. Window Frame Assembly(no glass) 10001803 10004920 35 Vermont Castings, Majestic Products: DVR33 !-{ DVR33 (continued) (Items marked`are not shown In the parts illustration.) Ref. Description DVR33 32. Window Glass with Gasket Assv 10000961 • Gasket Window Replacement 57317 33. Clamp Frame Window 54174 34. Window Trim Polished Brass with Magnets 55005 35. Top Louvre Assembly 10000292 36. Bottom Louvre Assembly 10000293 37. Hinge(Bottom Louvre) 52356 38. Wall ON/OFF Switch 51842 • ON/OFF Switch Kit 53875 39. Bracket Rear Log Assy 10004906 40. Relief Plate w/Gasket(Burner Tray) 10004192 41. Gasket Bumer Tray 10001035 42. Relief Plate w/Gasket(Firebox Top) 10002032 • Electric Box Assv(EB-1) ZA1200 36 10004920 Vermont Castings, Majestic Products: DVR33 Optional Access• Fan Kits Method A Route the 6' (1.8 m) lead fitted to the unit to a FK-12 Fan Assembly conveniently located wall socket. 1.Open lower louvre. Method B 2. Install FK12 fan in back of unit between hearth If EB-1 receptacle box(Pt.#ZA1200) was correctly supports (Fig. 49). connected when the unit was installed, the fan lead 3.Secure fan on Velcro strips. can be directly plugged into the EB-1 plug socket. 4.Power to the fan can be supplied by plugging the 5.Whether wiring directly to the fan junction box supply lead into a conveniently located wall socket (Option A), or into EB-1 electrical receptacle box or by using a hard-wired EB-1 connector box. (Option B), first ensure cable is secured using box 5. Be sure fan motor does not touch nearby metal. connector. The fireplace, when installed must be electrically Side View connected and grounded in accordance with local Cold Air codes, or in the absence of local codes, with the Box current CSA C22.1 Canadian Electrical Code or for FroUSA installations, follow local codes and the National Unit _of--� Electrical Code, ANSI/NFPA No. 70. Unit Hearth Pan Hard Wire (Direct) Hook-Up First connect ground wire to ground stud located on the Base Pan FK12 Fan base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed FP1004 switch wire connects to temperature sensor. Alternate Fig.49 FK-12 Fan placement. lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire (Fig. 51). FK-24 Fan Assembly Electrical Box Heat Fan specifications: 120 volt, 60 Hz, 0.75 Amp. Sensor Fan This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season. Should this fan require servicing, the power supply must be disconnected. \ The FK-24 comes with the electrical cord attached. Switch� Gas Line `Valve FP1026 1. Slide fan assembly from the left side into the fireplace opening, line up mounting holes with Fig.50 FK-24 fan placement. screw studs on back of fireplace and fasten with Fan #10-24 hex nuts. Temperature Sensor 2. Install thermal sensor on bottom of firebox using #10-24 hex nuts. Speed Control 3.Option A— Place electronic fan speed control box Black on bottom of fireplace base, lining up mounting white holes with screw studs. Fasten fan speed control Ground box with #10-24 hex nuts. I - FP1025 Option B— The speed control can be installed in Fig. 51 FK-24 fan wiring. an electrical box at normal wall switch height for Any electrical rewiring of this fan must convenient access. be completed by a qualified electrician. 4.Connect the power supply in one of two ways: Turn off all power before hookup. 10004920 37 Vermont Castings, Majestic Products: DVR33 r Remote Controls Adjustable Optional remote control units are available to control tab Adjustable different functions of the appliance(only for RN/RP - tab models). Log Model Function(s)Controlled pan i Back Panel Support MRC1 ON/OFF Side MRC2 ON/OFF and Temperature panel MRC3 ON/OFF and Temperature control Lower Lower with a digital display and a support support programmable 24-hour clock Floor refractory panel IMT Wall-mounted thermostat control FP1193 Fig.52 Install ceramic refractory panels. Ceramic Refractory Panels Ceramic refractory panels are available to line the Rear Refractory Panel firebox area. -- Unit Kit Model Rear Panel DVR33 DVR33CR Support Brackets Firebox Back Take care when handling the refractory panels as they are fragile until held in Rear L Su place and supported. °9 Support Installation (refer to Fig.52 and Fig.54) FP1194 1.Remove the window frame assembly Fig.53 Place the rear panel on rear support brackets. 2.Remove the logs. 3.Place the lower supports for the side refractory panels on the base of the firebox.Place each Decorative Bay Windows support so that the slotted hole fits over the forward screw head along the edge of the base. The original front frame/glass assembly 4.Lay the angular base panels in place on the floor of MUST remain in place when fitting the the firebox on either side of the burner housing bay window kits.The bay window kit fits assembly. over existing front glass. 5.Loosely attach the top adjustable tabs to the studs Bay window kits are available for model DVR33 located in the top of the firebox toward the front fireplace. comers. Installation 6.Place the rear refractory panel in place. Locate the 1.Remove the existing louvre assembly bottom 'small brick'edge of the panel into the two small complete with the hinges. supports on the back panel just above the rear log 2.Remove the louvre assembly top. support. 3.Assemble the Bay Window Kit according to the 7.Slide the side refractory panels into place to hold instructions supplied with the kit. the rear panel secure.Adjust the top adjustable 4.Place the 2 pieces of ceramic refractory along the tabs to hold the side panel against the firebox wall base of the bay window(Fig.54). and secure the tab. Repeat the procedure on the 5.Hang the Bay Window Assembly over the existing other side. window frame assembly. 8.Replace the logs and window frame assembly. 6.Reinstall the upper louvre assembly. NOTE: For aesthetic purposes,we recommend aligning the horizontal mortar lines. Do not remove the existing window frame assembly. 38 10004920 LIMITED LIFETIME WARRANTY r PRODUCT COVERED BY THIS WARRANTY ' All Vermont Castings gas stoves,gas inserts,and gas fireplaces,and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner,or standard steel tube burner. BASIC WARRANTY • Any part and/or component replaced under the provisions of this The Vermont Castings, Majestic Products Company (hereinafter warranty is covered for six months or the remainder of the original referred to collectively as the Company) warrants that your new warranty,whichever is longest. Vermont Castings or Majestic Gas Fireplace/Stove is free from • This warranty is limited to the repairof or replacement of part(s)found manufacturing and material defects for a period of one year from the to be defective in material orworkmanship,provided that such part(s) date of purchase,subject to the following conditions and limitations. have been subjected to normal conditions of use and service,after EXTENDED LIFETIME WARRANTY said defect is confirmed by the Company's inspection. • The company may,at its discretion,fully discharge all obligations with The heat exchanger,where applicable,and combustion chamber of respect to this warranty by refunding the wholesale price of the every Vermont Castings orMajestic gas product is warranted for life defective part(s) against through wall perforation.All appliances equipped with an Any installation,labor,construction,transportation,or other related Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque.Warrantees are made to the original owner costs/expenses arising from defective part(s),repair,replacement or otherwise of same,will not be covered by this warranty,nor shall the subject to proof of purchase and the conditions and limitations listed Company assume responsibility for same.Further,the Company will on this Warranty Document not be responsible for any incidental, indirect, or consequential COMPONENT WARRANTY damages except as provided by law. CAST IRON:All external and internal cast iron parts are warranted for a • SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR period of three years. LIMITATIONS OF/NCIDENTALAND CONSEQUENTIAL DAMAGES Note:On porcelain enamel finished external parts and accessories ORLIMITATIONSONHOWLONGANIMPLIEDWARRANTYLASTS, The Company offers no Warranty on chipping of enamel surfaces. SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR Inspect all product prior to accepting it for any damage to the enamel. CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC The salt air environment of coastal areas or a high humidity RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY environment can be corrosive to the porcelain enamel finish.These FROM STATE TO STATE. conditions can cause rusting of the cast iron beneath the porcelain • All otherwarranties-expressedor Implied-with respect to the product, enamel finish,which will cause the finish to flake off. its components and accessories,or any obligations/liabilities on the Dye lot variations with replacement parts and/or accessories can part of the Company are hereby expressly excluded. occur and are not covered by warranty. • The Company neither assumes,nor authorizes any third party to GLASS DOORS:Glass doors are covered for a period of one year. assume on its behalf,any other liabilities with respect to the sale of Glass doors are not warranted for breakage due to misuse or this Vermont Castings,Majestic product accident. Glass doors are not covered for discoloration or burned in • The warranties as outlined within this document do not apply to stains due to environmental issues,or improper cleaning and chimney components or other non Vermont Castings, Majestic maintenance. accessories used in conjunction with the installation of this product. BRASS PLATED PARTS AND ACCESSORIES:Brass parts should be • Damage to the unit while in transit is not covered by this warranty but cleaned with Lemon oil only.Brass cleaners cannot be used. Mortar Is subject to claim against the common carrier.Contact the dealer mix and masonry cleaners may corrode the brass finish. The from whom you purchased your fireplacelstove(do not operate the Company will not be responsible for,nor will it warrant any brass parts appliance as this might negate the ability to process the claim with the which are damaged by external chemicals or down draft conditions. carrier). GAS VALVES:Gas valves are covered for a period of one year The Company will not be responsible for. a) Down drafts or spillage caused by environmental conditions such ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and as near-by trees,buildings,roof tops,hills,or mountains. mechanical components of the burner assembly are covered for one b) Inadequate ventilation or negative air pressure caused by year.All steel tube burners are warranted for one year. mechanical systems such as furnaces,fans,clothes dryers,etc. ACCESSORIES:Unless otherwise noted all components and Vermont This warranty is void if: Castings,Majestic Products company supplied accessories are covered a) The fireplace has been operated in atmospheres contaminated for a period of one year. by chlorine,fluorine,or other damaging chemicals. CONDITIONS AND LIMITATIONS b) The fireplace has been subjected to prolonged periods of • This new Vermont Castings or Majestic product must be installed by dampness or condensation a competent,authorized,service contractor.A licensed technician, c) Any damages to the fireplace, combustion chamber, heat as prescribed by the local jurisdiction must perform any installation/ exchanger or other components due towater,orweather damage, service work. It must be installed and operated at all times in which is the result of but not limited to,improper chimney/venting accordance with the Installation and Operating instructions furnished installation. with the product.Any alteration,willful abuse,accident,or misuse of d) Any alteration,willful abuse,accident,or misuse of the product the product shall nullify this warranty. has occurred. • This warranty is non-transferable,and is made to the original owner, IF WARRANTY SERVICE IS NEEDED... provided that the purchase was made through an authorized supplier of the Company. 1) Contactyoursupplier.Make sure you have yourwarranty, • The customer must payforanyAuthorized Dealer in-home travel fees your sales receipt,and the model/serial number of your or service charges for in-home repair work.It is the dealers option Vermont Castings, Majestic product. whether the repairwork will be done in the customer's home or in the 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK dealer's shop. YOURSELF. • If upon inspection, the damage is found to be the fault of the manufacturer,repairs will be authorized at no charge to the customer parts and/or labor. Electric# APPLICATION FOR BUILDING PERMIT Plumbing#HVAC # 194 Lisa Drive Date: el -' .2d Sprinkler# 30568 __ FINAL P - - - - Estimated Cost $ 62Z. Buildin Of EL�7S PLETE RED BOXED AREAS Permit Fee $ U Engine Occuppancy Fee $ Affidavit TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr. for C oN ON REVERSE SIDE Total Fee $_���U• TO THE BUI ING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant 4 e ✓ y/->7 i W Location of Work <<'SA -br,'u R- Lot No. C Applicant's Address CT G' g,'uoe— �5 !�„ • Tel. # 2- Town ;--7 Zip 6'26�06 Lic.# .S�L✓,� c p Owner eLn110 Architect Owner's Address c' S C 3 Architect's Address d/ lcr �i✓ Zip_ �7i� %S •^ Zip Sq. Ft. New Area: 1st Fl. 5G 2nd,Fl. _ 3rd FI. Total New Area Purpose of this permit City Water$/ Well❑ Septic System❑ Sewer Ins: HO S Area Baseme Garage Approved ate 0 Use Group Construction Type Revised 6102 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any afterabon in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all lines,side yard lines,and required distances from all other zones and is located in which this bq ruse' II Signed leQr, .c ✓ I hereby apply for a Certificate of Occupancy for Uw work de h lication for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-30568-B 30,000 BO1 FOOTING 05/11/04 JFF A WITH CONTRACTOR 10 10IN PIERS B03 FRAMING (ROUGH) 06/09/04 JFF A WITH CONTRACTOR NEED BEAM SPECS STEP NOSING E03 ROUGH 06/09/04 JFF A WITH CONTRACTOR B04 INSULATION 06/15/04 JFF A R30 CEILING R19WALLS AN FLOOR RECEIVED MICRO SPECS NOTIFIED CONTRACTOR B10 FINAL 07/21/04 JFF A WITH CONTRACTOR B10 FINAL O8/11/04 JFF A CLOSEOUT **-18963-E 2,000 6/15/2021 Town of South Windsor Building Department h SOR CO. Building Permit: BLDP-21-392 APPLICANT NAME: Melissa Arel EMAIL ADDRESS: melissaa@rhinobackroofing.com ADDRESS: 532 HOPMEADOW ST SIMSBURY , CT 06070 LOCATION ADDRESS: 194 LISA DR South Windsor CT6074 OWNER: GAROFALO JOANN R 194 LISA DR SOUTH WINDSOR CT 6074 DESCRIPTION OF WORK: remove and replace existing shingles with new Owens Corning asphalt shingles,following code and manufacturer's recommendations. May 24, 2021 BUILDING OFFICIAL DATE SIGNED —ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT— PERMIT ONLY VALID IF SIGNED BY BUILDING OFFICIAL— EXISTING HOUSE D� �Lz1lJVLJ�LiVD� EXISTING HOUSE EXISTING DOORS TO REMAIN � ARCHITECTURAL GENERAL 5C01p E OF WORK: DESIGN J 301 Silas Deane Hwy "IT A . is rm CONSTRUCT A 25G SQ. FT, UNHEATED ENCLOSED PORCH TO THE REAR u OF THE HOU5E- 1 vvcierslield, %-L _ 860-721-1410 C� Ln Vj CV EXISTING HOUSE v MAKE FINISH FLOORS FLUSH NOTE: In The Garofalo Residence I Ln N BECAUSE THI5 15 AN ADDITION, ALL SHOWN _ c z _ z U _ _ DIIVIEIVSIONS IVIAY BE 5L1GH T LY ADJUST LD I N / 1 I I 'L,7 L15a vrive THE FIELD AS REQUIRED TO CONFORM WITH _ NCL_OSED PORH EXISTING CONDITIONS. A 5outh Windsor, CT Ln Ln I OF 9 1 0" DIA. CONCRETE DE N PIERS 42" BELOW GRADE I O W U PLACED AS SHOWN 0 - o° (4) 2 x G MEMBFRS BETWEEN I m 2 x , 0 JOIST @ I G" ON CENTER - �= ALL 3 PAIRS OF `MNDOWr WALL LEGEND _I Cal o (3) 2 x 10's AT SIDES — EXISTING WALLS R�In�Irlr 4T Nnrn czPON CN25 /CN25 NEW WALLS �� JOIST HANGERS ON ALL JOIST ' Framing fan Ile.00 8 Elevations — 16' (2) 2 x 10'5 AT GABLE WALL Ln A-A I 7'-5 Lil FLOOR PLAN - - SCALE 1/4" = 1 '- 0" 1'LOOK FRAM I NG PLAN NOTE: CONSTRUCTION OF THIS PROJECT TO SCALE 1/4" = 1 '- 0" COMPLY WITH ALL APPLICABLE BUILDIN CODES IN THE TOWN OR GOVERNING MUNICIPALITY WHICH ISSUES THE BUILDING PERMITS FOR THE SHOWN DRAWINGS. THE PERSON OR COMPANY TO WHICH THE BUILDING PERMITS FOR THE SHOWN PROJECT ARE ISSUED TO, ASSUMES ALL RESPONSIBILITY FOR COMPLIANCE TO ALL APPLICABLE BUILDING CODES AND ORDINANCES WHETHER THEY ARE SHOWN OR NOT SHOWN ON THESE DRAWINGS. I i EXISTING HOUSE ROOF SHINGLES TO MATCH WITH EXISTING HOUSE ,.1 � 11 12 i SKYLIGHT II 3± I ADDITION t, INSTALL GUTTERS DOWNSPOUTS AT EAVES, GUTTERS NOT SHOWN IILJII--] L-111-- L -L-J] 1Uu .1 L FIN15H FLOOR FLUSH FINISH FLOOR 51DING TO MATCH WITH EXISTING HOUSE APPROX GRADE EAST 51 DE ELEVATION NORTH ELEVATION WEST 51 DE ELEVATION SCALE 1/4" = 1'- 0" SCALE 1/4" _ 1 '- 0" SCALE 114" = I '- 0" INSTALL CONTINUOUS RIDGE VENT 2 x 10 RAFTERS @ I G" ON CENTER (3) 1 3/4" x 14" MICROLAM RIDGE BEAM R-25 FIBERGLASS INSULATION IN ROOF 1/2" ROOF * WALL SHEATHING 3± � r y PROVIDE CONTINUOUS AIR SPACE UNDER ROOF SHEATHING NOTE: NO TOP PLATE ON GABLE WALL, RUN WALL STUDS ALL THE UP TO BOTTOM OF RAFTERS \ SKYLIGHT OPENING 2 x G WALLS — SKYLIGHT TO SELECTED BY HOMEOWNER INSTALL CONTINUOUS SOFFIT VENT 3/4" T * G PLYWOOD SUBTLER R-1 9 FIBERGLASS INSULATION IN WALLS NO. DATE DE5CRIFTION FIN15H FLOOR TYPE TO BE SELECTED BY HOMEOWNER / 2 x 10 JOISTS @ I G" ON CENTER REV 151 O N 5 WITH BRIDGING AT MID5PAN (3) 2 x 10'5 �. R- FIBERGLASS INSULATION IN FLOOR DATE: 3- 1 5-04 1 0" DIA, CONCRETE PIERS SCALE: 1 /4° = I I- o° APPROX GRADE DRAWN BY: 5D CAD NO. GAROFALO I U 5EC;TION A-A SCALE 1/4" = 1 '- 0" Sheet # A- i