HomeMy WebLinkAbout194 CARRIAGE DR APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT f( 6 U jy 2 APP V 1540 SULLIVAN AVENUE Bldg.Permit# 1;,l 644-2511 ext. 230 Date Building Inspector,) Application must be printed or typed FEE SCHEDULE F ' Location of Job: $041,000=$15.00 (, �rri a 9 C DDA, Over$1,000= Street Lot No. $15.00 per$1,000 or any fraction thereof ignation Apt.No. APPLICANT p-'( oLA J �v�C� APPLICANT ADDRESS 134, /Lv.' 5,1-. S'o ae Cam= 060 W APPLICANT'S PHONE# OWNER q OW N S FOt ,q OWNER ADDRESS ��y ���r ��n - SO T OWNER PHONE ESTIMATED COST$ 4�56 4/51�0 , CJU ..j U IS THIS A CONTRACT COST? Yes "io FEE ENCLOSED$ O U TYPE OF JOB: -1(91 O OR-COS V"ew Installation Alteration/Addition/Repair 9_01 Do0 I ISo Revised 03/05/10 APPLICATION FOR HVAC PERMIT(Continued from ieverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑ HATING 3-kESIDENTIAL A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) Go ' FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) / FURTHER DESCRIPTION OF WORK 40/ G I "� ��i dr S'�^ �'t J /��rc-` 4- THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 303292 CONTRACTORS LICENSE NO. E STATE l SIGNATURE OF APPLICANT DATE € 8'PLASTIC SIDE STEP OP710N Nimperial January a M FROM B TO: FROM C To: FROM D TO: (RIGHT SIDE SHOWN) MANDrA I 2013 Lo .s C 44'-8 3/4' 0 4a'-8 3/4• A 44'-B 3/a• H 26'-3 3/4' H 21'-3' edition z z J /7 J 34'-F K 30'-6 1/4' K /1'�3/4' K 26'.13/4' 4 U U L 23'-4' L 28' L 17A 213 a w 2' Radius a y y CENTER LIGHT 4( 8'STEEL 8'PLASTIC N y rn U U PANEL OPTION STAIR OPTION STEP OPTION 20Y X 40' a W W W U)i F A 8 8 8 8 4 0 g 2R A B 2R 2R PART DESCRIPTION PART# °z m m � 2R zR 8'PLAIN PANEL 04101 7 6 7 7 1516 4' 8'SKIMMER PANEL 04102 2 2 2 2 2 2 8'RETURN PANEL 04103 3 2 2 2 3 3 4 4 < 8'PLAIN PANEL 04106 1 11 4'PLAIN PANEL 04110 2 4 11 11 4 2 8 8 SF 7 PLAIN PANEL 04114 1 1 7 RADIUS CORNER PANEL 04116 4 4 1313 4 4 RECT.STAIR FILLER-LEFT 04206 RECT.STAIR FILLER-RIGHT 04207 1 1 LIGHT 20' 17 5'SIDE STAIR PANEL 04120 1 1 PANEL 41-2j' ADJUSTABLE A+-P"E 04223 10 9 11 11111 11 8'STEEL STAIR 04188E 1 1 1 1 SF 8'STEP-NREST 07418SNR 1 1 8 4' 10 14' 17 8 NUT d BOLT PAK-75 pcs PAK-75 2 2 2 2 2 2 K NUT&BOLTPAK-100pas PAK-100 1 1 1 1 1 1 4 4 4 8'LIGHT PANEL 04104 4' 2R 4$q' L fflr. 2R --`77' 2R 2R I 8 8 8 8 4 RECTANGLE STAIR FILLER LEFT-04206 2 RIGHT-04207 —A-FRAME BRACE SF—RECTANGLE STAIR FILLER 6 SF 5'SS 5 �-'SSSIDE STAIR PANEL raoua� ahoE .ar»,..o• srwhrt fj- PANE. i 8'STEEL STAIR OPTION sBoTi "rEr • rOOL • w�u (3 CORNER LEFT SHOWN) �cas.m •nr�e..ns DIVING PERMITTED ONLY FROM DESIGNATED DIVING AREA. 37-1 40' �2T 1.Pow 2500 P.S.I.concrete footkig around entire perFneter,minimum B' i r g'MNA LED " deep. Ph�OTTOM 3'-4 3'4• S SIDE STAIR PANEL 2.Back fill with dean earth,free d roots and debris. •Lontrn h>oti®,• eonoM . UNIVERSAL FOR 3.3'wide concrete deck b to be poured at least 3'tlhidvhess and a slope $ hrw v.w-liv.w $ LEFT&RIGHT of Y.'to 1'away from the Pool. ANSYAvSPd m11 04120 4.All inside pod dimensons are to be finished dimensions. i1en0i 0t SEE 5.Finished bottom Is to be 2'minimum of suitable materiel or undisturbed sT� ru+a is,earth. 6.A safety line,with buoys,Is to be permanently attached 1V to the 17 4' 17 1 4' shallow side of the point of first slope change. BACK BOTTOM SLOPE SHALLOW SIDE BOTTOM SIDE 7.Construction Drawing:Different methods and precautions may be WALL PAD END WALL PAD WALL dictated by various ground conditions. This Is to be determined by and manufactIs the responsibility rer off the�p parts.or I'° not an�"`of"e ALL DIMENSIONS ARE FINISH DIMENSIONS "a S.Installation Is to be done In accordance with a1 federal,state and local bugding codes,as well as ANSI/APSP suggested standards. The bream co N-adm si,~oonlom"wih anent ANSI IAPSP•ligwt•d mYdnm `�ISk w ,flow—pools `p�W for heoww.,A oh m._rSk.ddh`,'.uss W..f*`lmxh4"'"d Volume: 27900 gat / 105600 L Perimeter: 116'-7" / 35.53 m Surface Area: 796.57 ft 2 / 73.99 m2 Liner Sq. Ft.. 800.0000 27 r knfalled,fobow sis•qulpmerd menJferllnrs tutaeWon.w•nd a•fdy Me++cnone. i cWN&Ucam am* --�:7 NOMINAL— "Nows WKI - ruy be Main Drain/ Suction Piping by-6- -ed g '1600L CONCRETE DECK conAlana Ymblobe r PW mmm) MAX V 3 86 GPM tiParrElkyarft - Is nd M soot ct ft Avnwbctm • RATED FOR off*owroarwo poft MAX MAX 125 GPM LrrOMNfon W:bo*mh WML 2.8 FPS Hayward 8* wiWna OM ,A 'MW NON-DWAKU C: MAX 2.8 FPS Round Cover w.d1well,141 oadl%as walso . A.M.311N.S.P1 an da (See Pump ADJUSTABLE Curve Max VINn L24M A-FRAME GPM 0 48 rWKCONCRM To Pump TDH is 86 COLLAR AROUND I= GPM) 95M psi MI OF POOL 2.5' Pipe MAX r MIN.FILL MMUM) POOL Wffom 5.6 FPS 0 CO Ga it IK 5 { HAYWARD'Pool Products I Hayward Industriai A Hayward Industries, Inc.Company Ctemmons.NC 270;2 336-712."00 www.haywardnet.com CERTIFICATION OF COMPLIANCE I Contains: WG1048E or WG1048EW Description: 8" Round Suction Outlet Cover Ratings: Floor: 125 GP.'4I Wall: 72 GPM Opcn Area: 8.1 sA-in Certified to Comply with Section 1404 of the Virginia Graeme Baker Act(VGB)Pool & Spa Safety Act i Tcst Results can be obtained from:www.Havwardnet.com and/or hgp;/!`www.nsf.oreXcrtifiedPools -%lat:ufactured: After December 20, 2008, by Hayward Pool Products in Jiangsu Province,China and I Ocmmons,NC Divisions of Hayward Industries, Inc. 620 Division Street, Elizabeth,NJ 07207, Phone 908- z;:-'99� Date of Mfr: The Lot?Number shown on the r p oduct label contains the Year&Month of manufacture. The rst number represents the year(ex 8 =2008)and the second character the month (A=Jan,B=Feb,H=Aug, I is skipped. J=Sep, etc) T:>ted m ANSUASME i I2.19.8-2007(addendum 8a-2008)per Section 1404 of the Virginia Graeme Baker Act (VGB)Pool & Spa Safety Act. Certified by NSF International, 789 N. Dixboro, Road, Ann Arbor, MI. � 48 i 0� 1(800)-NSF-MARK. of Installation: i ISWGIO48COC Rev B j., --'� SPACiNG BE*;'NEEN ,f �UNi;;� i I USED ON FOLLOWING SERIES: OG 00 WG1030AVPAK2 SPT030AVPAK2 0000000 WG1048AVPAK2 00000 SPT048AVPAK2 0 ,.* 0000000 WG1049AVPAK2 SP1049AVPAK2 0000 0000 WG1031AVPAK2 OJTtEt 0000 0000 0 SP105IAVPAK2 _ . _� ,���J, G48E 0000 0000 WG1052AVPAK2 SP1052AVPAK2 Qp00000 WG1053AVPAK2 SP1053AVPAK2 OQO0000� WG1054AVPAK2 SP1054AVPAK2 000 0 WG1153AVPAK2 SPT153AVPAK2 WG1154AVPAK2 SP1154AVPAK2 G !cD LANE HAYWARD Poop a�ouu One source. Ever; 1 2000/2050 SERIES • 2' RADIUS RECTANGUE • 18' x 36' ®HAYWAMPwRod" tty,.,.t•a.a.ro.r. r A IIwW Maalat MoLL•pry cwmn.Kr(C 77ot1 r aw 314IgAaIa •varxctnaw — IF DOUBIB DRAIN IS PURT418fIRD � - ---- a••ocwoettsl•truaai A9MR AI1119A AT 3,-0"bw APART 9i�-700M1111O�'•rs:M. _ f le i/ (TRTMCA'RUN OF CUMI'LIANCE �— urwutr•rn�a000tet• r•tramrd•-•ooww•••.cY - [Conte-ins:WGIS48Bor WGIO489W DtatllQtlat:8"Ramtd Swetion Outlet Goner vt.w•s ... wtxa•:Pbor:T 2)147M! Wad: 7a GPM Opa Ara:_ ♦Jace*t 1+r tvu s• ":'; ._. .y° ra ameN t"`•` ---... .�M-- - - -- a,•0"10M •�••' ckrufied fo()amply vikh Ssctioq 140i of e6e v' «t« •taAw tt�ia Otamta BZ Aet a(Nr �we111i'e►NIK sr s� a. Tat Rmdm can be obNiurd 8 ong�mVa ( )Yod&Spa 9ahty A. OMaa atgnaterwtn h � . a•tw eAar!» Muw6cmred:AOer December 20,2098.by H4ytud Pool rtodmb m llCljae PAiv1N•q Chios and teta t wtwrees _ I ` t ' a CU 7i umm,NC Diwtau of H�ywud hkkw icc,hie 620 Divieian strra,EdabeAt,w mzm,shoes 908- ott -j n------- • oom r e•aur auto \. Date of MG mm :Tbc Lot Nber shorn on ttte Mdm label conkim the Year&Mandl of mm dstftm The gcxar t+nan•tan '•'} 0qt ne k"f the 20OR ( Av&I a ompopp qne ` f( rSp,-1c)tta yar(at 8- and the s000ed abarectet the mowh Arlan B=Feb, awtn awrrn+a *' •• t• I - T•esW to AT'3YASME It 119.8-1-007 ddwdror 8a2 twr �aat8aga ♦ y a • Act Vl7B)I'ad& ( �per 9atiaa 140/of We VirSinu Graema Bakcr tnru tratttowmtr Act( l Spa S•hty Am Car86ed by MW bWBWMA 789 N.MUM Road,Ann Arbor,Mi. awls twt•attoarrwc. � � (800j-NSF-MARti:. lsere•atra Itat- W 7c1 -��.__.� 1i� a, avert rw`rrtv.et `I • • I- Date ofI&MV Lrfdldm:----- tSWOtoaM70C Rry s WR•M!M � ___ w �rppq�{�t�a1 • a __ w,� a'a►IrraM/tM11R a� -tMw SPA'CSW SME-W tara..a.t.s.r•t•.+wa••rr. . i.�:i` :.wrt..•n•..f.r� . r�.•rr.rr.r.rr.ewr,l r f- _tr- _ ; l ..a• >a r tfsao arfouowtNcI:cwfx •T.r•1:•rwwaewwyryww.wr '•' r °r s+ � �� � -ram ( ��04�VrA� S.%(WAYIryA�. .aw.r« •.•t.wr .e L �i�/C &iMYIX S AVPAlC7 SUC:U()N C1U1(L�I O o. w•.wt...o.tr�•wa.oai�r+r 1-..-.L----w ,rJ !_�._.t—.a 1 _ ►Or AY►A IC!' . ..a.o+rrra+a..•aruaar w � tr--•--�1� CCtV9P.NG1W8E• 1 Tlt! �fl1 f at•w•rwwt Ili` r O {6i�J1gI Sf a••• ..•... ALL DIMENSIONS ARE FINISH DIMENSIONS �� }Zy ....rr•riaa•• ___:_ ___.._.___ _____._..r_._ „'- vlRK2. Stl1S1AYlAK�'2 /1'It�;n 0��.:n 5/ (.rr�ol✓ ��rn �' :r'�ONp f I Uj I�r `QS.7ONA1-� STANDARD NOT1:1: 2 I Mac 11J413 7."SCHEIMIX.40 PVC PIPE kX*MAIN(MAIN OR SUCTION OUTUr LINES JtrwesA I 2 THE NLOOR DRAIN MI'IsTS T7fli RI3q)IREMIWIS OF ANSI/ASME A 112.19.8-2007 !"h' FOR ANTI-HAIR AND DORY FN1RAPMFNT AND ANSI/ASP-7 2006 STANDARD 2 7-� 3 7HIS DRA WINO WILL.SUPPLPMf9JT'(X*n RA(,'RW-',f)RA WING ON FILP. ie�A4atutJlc Q'Iti•atM•aw tt�Mr•Le•uae 171r! I PATF Sounds olarrr. if children or Pets fal1 ffif+o your pool i i i HE COMPLETE "POOL PATROL " POOL & SPA SEC URITY ' 'YS TEM he Pool Patrol Pool Alarm >TM (The Pool Patrol meets the requirements of ASTM Standard F 2208) • Meets Requirements of ASTM Safety Specificatio F2208-07 • Easy to install with no damage to your pool • Adjustable sensitivity to z Easy to install, conve 4wt to use reduce false alarms a Helps to detect intruders- 9 volt battery powered a Floats on pool surface Low battery indicator 2 Battery Powered K Low battery indicator The only floating alarm ft i Corrosion meets ASTM Safety s resistant Specifications for long life Works in any type, shape, -sY 11 Ideal for both or size pool or spa r - m-ground and Also protects commercial above-g7°und pools and spas _ pool New advance - ci �me al microprocessor design t5 SS Latest RF technology _.. • in house remote receivgr ° • Alarms at 85+ dB at 10 fe • One alarm can monitor a 20' x 40' pool • Multiple alarms can be used in larger pools • Alarm can be used witha solar cover • Will detect children, pets, or objects 15!bs or larg 6 r. SELF CONTAINED UNIT WITH LOCAL SOUNDER ALSO TRANSMITS TO OUR REMOTE RECEIVER(ASTM) 7e Pool Patrol Door & Gate Alarm;' W11�1 lea Poolguard Alarms•pool alarm,door alarm,gate alarm,pool safety,child safety HOME I CONTACT US I BUY POOLGUARD I PRODUCT Wd Nilrtt:$I WMRAN Y REGISTRATJOrw � Read Before ricr?oC, {c �, You Buy. MOMfr�r� Poolguard Alarms: DOOR ALARM - Model DAPT-WT - SOUNDS IMMEDIATELY! •Pool Alarm—Model PGRM-2 • Pool Alarm—Model PGRM-SB •Gate Alarm Door Alarms - NEW •Door Alarm-DAPT-2 - (Sounds in 7 seconds) •Door Alarm-DAPT-W I +. (Sounds Immediately) ; Other Information: •Contact Us •Buy Poolguard - •Product Manuals •News From Poolguard •Warranty Reaistration POOLGUARDIPBM INDUSTRIES,INC. has been manufacturing pool alarms,door . UL Listed to UL 2017 alarms, and gate alarms since 1982.All Poolguard products are proudly Made in • Sounds immediately when the door the USA Poolguard Door Alarms comply opens with all building codes and are UL Listed • Outdoor wireless transmitter pass- under UL 2817.The majority of children thru feature that drown in pools go out the back door • Simple To Operate first and Pooiguard`s Door Aiarm can help • Easy to Install protect those doors.Adult pass through feature allows 15 seconds for adults to • Important safety alarm for doors pass through the door without the alarm • Complies with barrier codes sounding. • Low battery indicator • Battery powered • Automatic reset POOLGUARD DOOR ALARM WITH WIRELESS FEATURE 1 Year Warranty Complies with all building codes Loud SUB horn(at 10 feet) http://www.pooiguard.com/door-YAreless.asp a:17/2U!4 Poolguard Alarms-pool alarm,door alarm,gate alarm,pool safoty,child safely PST - • The Door Alarm will sound immediately when a child opens the door,and will continue to sound if the door is left open. If a child goes through the door and doses It,the alarm will sound for 5 minutes and then automatically reset • Pooiguard Door Alarm Model DAPT-WT is equipped with an Outdoor Wireless Transmitter that allows adults to enter the home from the outside without the alarm sounding and is easy to Instal'. • The Door Alarm is always on and will automatically reset under all conditions. • Poolguard Door Alarm is equipped with an adult pass through feature that will allow adults to go through the door without tie alarm sounding. • Optional screen door kits can be purchased for the alarm,this kit allows you to get air through your screen door without the alarm sounding. • Poolguerd Door Alarm uses one 9-volt battery,(not ncluded)with a battery life of approxim. teiy 6 months. • The Door Alarm is equipped with a low batteryindicator that will audibly ly alert you when your battery is getting low. • Pooiguard is the only door alarm that is UL listed under UL 2017 for water hazard entrance alarm ui ment. � P Door Alarm-Wireless PDF manual All Pr'Oducts ProtllcRy .. 3roa�c i../ j 1 u -7 http:/Avww.pootguard.com/doo,,-Mrei"sasp Lf G % LA 1 1" J C1 ?�._ _ •,z.�r �'3 <^ a �^� L� � t+ `"�:, � � T Y � v�.,,-dry ^^'�� f-i a,�, � ; .�' � A r�— -^� Spectra color chain-lirdk provides the,corrosion proteccio n of zinc addition�to the durabil it�' an -attractive appearance of Polve'Ster framework and ex TY C-,b rid truded- lywin 0� e fabric- UM-16-M_ c=oat izing die pre-treatiritnt roc�ss.then color coated with a 3 mil n1ml mum polyester layer for corrosion. 11 RalvariLed wire has a 15 mil minkin _ extruded Poh�dny I artreanng Protection from corrosion and the ekmenu,, rtm'C's are made of galvanized steel with a 6 mil minimum of 1�7' reating compon-ents With b6th Zinc and an electrosta 'caliy applie ' color soaring helps them provide years of r protection and security. roe rnked warrano, --ides confidence a d assurance that You've 2 year 1i selected one, e best color chain-li—nk fence systems available- MASTER -C ts AST"M F 668 Class 1 ASzT, -M F 668 Chiss?k qx>_-mcadans HAL Spectra is the perfect choice for property owners who need the strength and protection of a chain-link fence system plus an appearance that blends in beautifully with the environment. Spectra defines property tines,encloses animals,as well as protects and adds value to any property.For added.privacy, choose from diflCtent types of decorative polyethylene slats Sierra Brown Midnight Black Forest Green tinted to match the shades of Spectra color chain-link systems. Note: Due to tuanu6ctutvig Variatxes and 16aitatiQau In t]tesction pmoess coiats maf v2rg hom this b=dmv_Contaa Mww Pwco for actual color samples. Chain-Link Fabric Framework Spectra polyvinyl chloride extruded over tine-coated steel Spectra polyester resin,3 mils minimum,over galvanized wire per ASTM F 668 Class 1 or Spectra polyvinyl chloride steel ASTM F 1043,Group 1C,with a minimum yield Type extruded and adhered toiinc-coated steel wire per 2 strength of 50,000 PSL Protective coating per ASTM F ASTM F 668 Class 2a � 1043,extemal.coating Type$,zinc with organic overemt, $and finish 0.9 ounces per square foot minimum zinc coating with uge VuSe' chromate conversion coating and verifiable polymer film esh 2'and 1-1/4'pool mesh Top Rail 1-3/8'O.D.Spectra 16 or 17 Ga pipe Pe eights 3',42%4',5'and 6' Line Posts 1-5/8'or 1.7/8"O.D.Spectra 16 Ga.pipe Selvage Knuckled top and bottom up to 5'high,twisted and erminal knuckled 6'high oau 1-7/8 or 2-3/8"O.D.Spectra 16 Ga.pipe Fittinp Swing Gates Pleeves n and&ace olpmer coatrng,6 mils mii>imum;over hotdlpped Same mesh gauge as chain-link selected vanized'ptes�ed steel Eye Tops, olymencoat.6 mils minimum,over i work 1-3/8'or 1-5/8"O.D.for gates ads lvanized esmd aluminum oiymer coating,6 mils minimum,over hot-dipped lvanized steel rie Wins -[polymer coating.6 mils rninintum,over zinc-coat �teel wire i mce=, er_ bias gr�wii to' cot�see �er I4c[sut� �tes a broad range oferttug.s3aurtcn�fo. largest tnariifazt�rer and dismbutor of feet.me ttratertals xturs erciai and neii3 lieatet tiai -snel it me World,servicing tlacumrt,3s of d-we b-t install zs and retailers acioss the Urjted✓tares ail^Car y`s e r-y' loC 360r6 acmes a vezz T*tsw.xk of try our - a t_cr de�'ty met. ,r For:more in Liar.a9out faaier Nalco praauc -- __ Hli�I = serFices call 1.58tx.W:ror N HP&CO' ww�v.�-ee�ueC0nlirte cam.:: 4t?V W.hkuap ktan Grange Ct.92S68 -= 1-5S8-A41.1,F�{:E iici_l= - x�vu•.Fe:•:cAr�tiue-zoo - Mosix raso sesames See 44 a a d>WtXMr or make ai ;arcs - i C a}C11 ►�'1�L�`CiY��Sw� �-o b� �o�c�,teC,� m:�:r��.w. scJ,�1JC away ��m -}�nO! y g>> pox Yv)o- . A �T tO1/M It+t� 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 06074 s SOR•C0� AREA CODE 860/644-2511 ~� July 13,2001 CERTIFIED#P462498159 Roy and Carol Ingalls 194 Carriage Drive South Windsor, CT 06074 Re: Appl. #2505-01 —Roy and Carol Ingalls, 194 Carriage Drive,A-30 zone Dear Mr. &Mrs.Ingalls: At the meeting of the South Windsor Zoning Board of Appeals held on July 5,2001, the Board approved your request for a 10' variance to section 10.2 to allow a 40' building line along the easterly side of the property at 194 Carriage Drive,A-30 zone. The Board concluded the hardship on the property to be that there is no plan any longer for the construction of a roadway in the future, so it was felt that the addition proposed was reasonable. Any new building,or alteration/additions to existing buildings,requires a building permit prior to start of construction. These actions are effective upon your filing the enclosed form in the Town Clerk's Office at your own expense. Very truly yours, N":E,L.L rLafh e-liul Marjori thony, Chairperson . Zoning Board of Appeals MA:dr cc: Building Department I,Marjorie S.Anthony, Chairperson of the South Windsor Zoning Board of Appeals hereby certify that on July 5,2001 the Zoning Board of Appeals granted to: Roy and Carol Ingalls, a 10' variance to section 10.2 to allow a 40' building line along the easterly side of the property,A-30 zone. on premises located: 194 Carriage Drive and more particularly bounded and described as follows: NORTHERLY: By land now or formerly of the Connecticut Light and Power Company, One Hundred Fifty and No One- hundredths (150.00 ') feet; EASTERLY: By land now or formerly of Louis Lipman, et al, shown as Reserve for Future Street" on said map, One Hundred Seventy-five and No One-hundredths (175 .00') feet; SOUTHEASTERLY: By a curve connecting said Easterly line of said Lot No. 11 with the Northerly line of Carriage Drive as shown on said map, Thirty-Nine and Twenty-seven One-hundredths (39.27') feet; SOUTHERLY: By Carriage Drive as shown on said map, One Hundred Twenty-five and No One-hundredths (125.001) feet; an WESTERLY: By Lot No. 10 on said map, Two Hundred and No One- hundredths (200. 001) feet. OWNER OF RECORD: Roy&Carol.Ingalls Dated at South Windsor, Connecticut this 13th day of July,2001. r• Marjori Antho y, Chairperson PUBLIC ACT#75-317 Received for Record this day of 2001 at VOLUME PAGE TOWN CLERK Page 1 of 1 VOL. 1.2 30 PAGE "7 4162 9 2 I,Marjorie S.Anthony,Chairperson of the South Windsor Zoning Board of Appeals hereby certify that on July 5,2001 the Zoning Board of Appeals granted to: Roy and Carol Ingalls,a 10'variance to section 10.2 to allow a 40'building line along the easterly side of the property,A-30 zone. on premises located: 194 Carriage Drive and more particularly bounded and described as follows: NORTHERLY: By land now or formerly of the Connecticut Light and Power Company, One Hundred Fifty and No One- hundredths (150.001) feet; EASTERLY: By land now or formerly of Louis Lipman, et al, shown as "Reserve for Future Street ' on said map, One Hundred Seventy-five and No One-hundredths (175 00') feet; SOUTHEASTERLY By a curve connecting said Easterly line of said Lot No 11 with the Northerly line of Carriage Drive as shown on said map, Thirty-Nine and Twenty-seven One-hundredths (39 27') feet; SOUTHERLY: By Carriage Drive as shown on said map, One Hundred Twenty-five and No One-hundredths (125.00') feet; an WESTERLY: By Lot No 10 on said map, Two Hundred and No One- hundredths (200.001) feet. OWNER OF RECORD: Roy&Carol Ingalls Dated at South Windsor,Connecticut this 13th day of July,2001. Y Marjol orid.6 Antho y,Chairperson U PUBLIC ACT#75-317 Received for Record this /(D hQ day of LLW 2001 at 8' 0Sca rr, VOLUME 1a,3 CQ PAGE 1-1 I,' TOWN CLERK / iakm_y J�+��-a /ya�iS�o.rY Volume: 1230 Page; 79 File Number: 004162 Seq: 1 a l l q q ca D� 160614 1� 1 N �' S Wi c �— (1) ROAD � e (0 � — f'G o H c A 0 o� OL��O1 sTRFfT -.^� ti 1� Zr ti V n/f E Connecticut Light & Power Company Proposed fence sr.k 1 o W 0_ Z GIS Pin 798OL002 SRt h V \ ROSSING F SHAGBARK Proposed 6' pool patio RD. 74 G Contractor to set elevation in the field based upon maintaining °tiS P o ADA compliant sidewalk from access at the rear of the garage. Q Pam° o �0 00�� < P W T�p S Q Proposed concrete sidewalk. Contractor to ensure that sidewalk complies Connecticut Grid System with all ADA requirements. (NAD 83) �O klLL /O� p 3 Area reserved for ROAD o 0' 20' 40' 60' q� p / \ �3 \ Future Street 9 oq >` Landscaping to be removed o r H Existing asphalt ramp =No,,\ Dlc you DRI£ BtRCH ti U < Shed Proposed << / 20 Pool Shrub yGro Of � SCOTT Existing treeline w DR�H 5c°mac / Existing propane tank ELLLN CC F e P a� Q Deck Shrub Site Location Plan Shrub Scale: 1 = 1,000 � Existing pool to be removed 0 / \ 0=90.00,00" l R=25.00' v w CY) /� w L=39.27' Q w w W / / \ � \\\ GSe ,� X 238.1 Cq cl�x O Approximate location of proposed �� \ \\ \\ / // pool equipment (pump & filter) �� Edge of existing �•� �p� ��'O, wo landscaping (typical) n w ^ � �2 38.2 Nr Monument 0 1 _­� \ / / Recovered Y 235- / 235.4�25 NI U /235.9 O Nancy Walker " > #200 Carriage Drive Q / / , 4!z' / GIS Pin 17100200 o/'/ /233.6 / op/ / - 4 / Iron Pin /233,E/ / V / / Underground telecom Recovered / O// r / /231.3 / /231.1 P, O �� /229.5 U 1� 228.2 / r.! v - SURVEYOR'S NOTES: // r x/228.0 ( /J 1a�f 1. THIS SURVEY AND MAP HAVE BEEN PREPARED IN ACCORDANCE WITH THE "RECOMMENDED STANDARDS V V FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ADOPTED FOR USE BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC., ON SEPTEMBER 24, 1992, EFFECTIVE DATE JANUARY 1, 1993. SAID STANDARDS ENACTED BY THE STATE OF CONNECTICUT (SECTIONS 20-300b-1 THRU 20-300b-20 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES) EFFECTIVE JUNE 21, 1996. *.--� 2. THE TYPE OF SURVEY PERFORMED IS AN IMPROVEMENT LOCATION SURVEY AND IS INTENDED TO Limited Property/Boundary Survey DEPICT OR NOTE THE POSITION, HORIZONTALLY AND, WHERE REQUIRED, VERTICALLY, BETWEEN PARTICULAR EXISTING OR PROPOSED IMPROVEMENTS WITH RESPECT TO THE APPLICABLE MUNICIPAL OR STATUTORY Improvement Location Survey REQUIREMENTS. THE PURPOSE OF THIS TYPE OF SURVEY IS TO ENABLE DETERMINATION OF COMPLIANCE WITH SAID REQUIREMENTS. NO OTHER IMPROVEMENTS OR FEATURES NEED BE DEPICTED. Proposed Pool 3. THE BOUNDARY DETERMINATION CATEGORY IS A DEPENDENT RESURVEY. 4. THIS SURVEY CONFORMS TO A HORIZONTAL ACCURACY STANDARD OF CLASS A-2 AND A VERTICAL Land of ACCURACY STANDARD OF CLASS V-2. TOPOGRAPHY AS DEPICTED HEREON CONFORMS TO AN ACCURACY STANDARD OF CLASS T-2. Iron Pipe Ne re id a Quinones Recovered 5. AZIMUTHS AS DEPICTED HEREON BASED UPON THE CONNECTICUT GRID SYSTEM NORTH AMERICAN #19 4 Carriage Drive DATUM OF 1983 (NAD 83). ELEVATIONS AS DEPICTED HEREON BASED UPON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). BOTH DATUMS ESTABLISHED BY GPS. jV LT 1 N South Windsor, Connecticut 6. REFERENCE IS MADE TO THE FOLLOWING MAP(S):a. PLAN OF SAND HILL ESTATES, SAND HILL & ELLINGTON ROAD, SOUTH WINDSOR, CONNECTICUT. SCALE: 1" = 40'. MAY 2, 1970, REVISED TO NOVEMBER 1972. MAP n NOT VAS ID WIT ' OU - Drawn: CJULIANO ' PREPARED RECORDS. BY JAMES E. SHEEY, LS #7034. SAID MAP ON FILE IN THE SOUTH WINDSOR LAND TO THE BEST OF MY KNOWLEDGE AND 9 Date: 06/06/16 Scale: 1 = 20 Iron Pin �' '� 1973 2010 Designed: CJULIANO BELIEF THIS MAP IS SUBSTANTIALLY I Checked: CJULIANO sheet 1 of 1 7. PROPERTY IS SUBJECT/PRIVILEGED T0: RIGHTS, RESTRICTIONS, ENCUMBRANCES, COVENANTS, Recovered 1 Project n0.: 16-161 EASEMENTS, ETC. AS THE RECORD MAY APPEAR. CORRECT AS NOTED HEREON. Released: CJULIANO Revision : 0 8. THIS BOUNDARY OPINION WAS MADE AND SURVEY MAP PREPARED FROM INFORMATION CONTAINED IN `7�,(} (� The information contained herein is the proprietary and confidential property of DEEDS AND MAPS OF RECORD, ALONG WITH PHYSICAL EVIDENCE LOCATED DURING THE FIELD SURVEY. David W. Juliano L.S. #08033 i' / OC I �>� Juliano Associates, LLC. Reproductions, publication, distribution, or duplication in whole or in part requires the written permission of Juliano Associates. This Christopher S. Juliano L S. #19725 document and copies thereof are valid only if they bear the original signature DATE DESCRIPTION Engineers & Surveyors and embossed seal of the designated licensed professional. Any alterations This document is valid only if it bears an original signature and 405 Main Street (Yalesville) render this document null and void.©Copyright 2016 , All Rights Reserved. embossed seal of the designated licensed professional. Any RIGINAL SEAL Wallingford, Connecticut alterations render this document null and void. AND SIGNATURE REVISIONS (203) 265-1489 M:ISUBMITTED120161161002-1-O.DWG 6/7/2016 8:59AM CJ RECEIvIED JUN 14 Z016 South Windsor Building Department CERTIFICATION OF ZONING COMPLIANCE Proposed buil6ng(s), use(s) and/or structure(s) as shown on this plan appear(s)to be in conformance with current South Windsor regulations. Variances and special exceptions may apply. Dafe Zoning Enforcement Officer l Y ro jy r� pv 0j , t V\ c 0+rp)t C,^C (,i ri � O c rNDSHIRE A? �P IP ROAD o S � Or � 0Ily ti �1 0 n/f Connecticut Light & Power Company Proposed fence ST.x p L002 Sand Hill Road S �e'E' SHAGBARK Q Q.. Z � CIS Pin 7980L002 � Proposed 6' pool patio RosstNG S R°eye RD. l G Contractor to set elevation in the field based upon maintaining Qi ADA compliant sidewalk from access at the rear of the garage. 0 '0,�4 S Q Proposed concrete sidewalk. �fQyq Contractor to ensure that sidewalk complies Connecticut Grid System with all ADA requirements. (NAD 83) !p� p Area reserved for ROAD o 0' 20' 40' 60' `�o�\ Future Street >1 Landscaping to be removed v O �Fb DR��f BtR�H O �• Existing asphalt romp 4 Shed Proposed H1L 20'x40' � o G,o y Pool Shrub °yo Z ry©`r ,�j, SCOTT Existing treeline ELL1NCIao R� o Existing propane tank p -� x° \ ` Shrub site Location Plan 0 �°a� o/ Deck Shrub Scale: 1 = 1 000 +-> Existing pool to be removed Cq o=90'00'00" R=25.00' �- `> L=39.27' Q 0 Bilco V /� ` �^.L � X 238,1 N y r Rj Approximate location of proposed `•/ o ( C 6 pool equipment (pump & filter) `��� Edge of existing landscaping (typical) /\--238.2 z Monument _ / ✓ ® 1 f� Q � /� / // Recovered �Q1 y 235.4 � .�7 h"nyo0 / �/235.4 /235,9 /NancyWalker d O "� > #200 Carriage Drive \� CIS Pin 17100200 ao�% /233,6 �e Gco� ✓' ¢OQ' / Iron Pin 233.6 Underground telecom Recovered •�i;f '\ • / /231.3 / /231.1 /229.5 V / / /228,2 / - SURVEYOR'S NOTES: / /228.0 1. THIS SURVEY AND MAP HAVE BEEN PREPARED IN ACCORDANCE WITH THE "RECOMMENDED STANDARDS FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" AS ADOPTED FOR USE BY THE CONNECTICUT ASSOCIATION OF LAND SURVEYORS, INC., ON SEPTEMBER 24, 1992, EFFECTIVE DATE JANUARY 1, 1993. +�-� SAID STANDARDS ENACTED BY THE STATE OF CONNECTICUT (SECTIONS 20-300b-1 THRU 20-300b-20 OF THE REGULATIONS OF CONNECTICUT STATE AGENCIES) EFFECTIVE JUNE 21, 1996. .� 2. THE TYPE OF SURVEY PERFORMED IS AN IMPROVEMENT LOCATION SURVEY AND IS INTENDED TO Limited Property/Boundary Survey DEPICT OR NOTE THE POSITION, HORIZONTALLY AND, WHERE REQUIRED, VERTICALLY, BETWEEN PARTICULAR EXISTING OR PROPOSED IMPROVEMENTS WITH RESPECT TO THE APPLICABLE MUNICIPAL OR STATUTORY Improvement Location Survey REQUIREMENTS. THE PURPOSE OF THIS TYPE OF SURVEY IS TO ENABLE DETERMINATION OF COMPLIANCE WITH SAID REQUIREMENTS, NO OTHER IMPROVEMENTS OR FEATURES NEED BE DEPICTED. Proposed Pool 3. THE BOUNDARY DETERMINATION CATEGORY IS A DEPENDENT RESURVEY. Land Of 4. THIS SURVEY CONFORMS TO A HORIZONTAL ACCURACY STANDARD OF CLASS A-2 AND A VERTICAL ACCURACY STANDARD OF CLASS V-2. TOPOGRAPHY AS DEPICTED HEREON CONFORMS TO AN ACCURACY STANDARD OF CLASS T-2. Iron Pipe Ne re ld a Quinones Recovered 1 5. AZIMUTHS AS DEPICTED HEREON BASED UPON THE CONNECTICUT GRID SYSTEM NORTH AMERICAN #1 `^^� Carriage Drive DATUM OF 1983 (NAD 83). ELEVATIONS AS DEPICTED HEREON BASED UPON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). BOTH DATUMS ESTABLISHED BY CPS. I 1 South Windsor, Connecticut 6. REFERENCE IS MADE TO THE FOLLOWING MAP(S): N o a. PLAN OF SAND HILL ESTATES, SAND HILL & ELUNGTON ROAD SOUTH WINDSOR, NOT VALID WIT OUT Drawn: CJULIANO CONNECTICUT. SCALE: 1" = 40'. MAY 2, 1970, REVISED TO NOVEMBER 1972. MAP Date: 06/06/16 Scale: 1" = 20' RPREPARED ECORDS. BY JAMES E. SHEEY, LS #7034. SAID MAP ON FILE IN THE SOUTH WINDSOR LAND Desi TO THE BEST OF MY KNOWLEDGE AND 1973 2016 9ned: CJULIANO Iron Pin BELIEF THIS MAP Is SUBSTANTIALLY Checked: CJULIANO sheet: 1 of 1 7. PROPERTY IS SUBJECT/PRIVILEGED T0: RIGHTS, RESTRICTIONS, ENCUMBRANCES, COVENANTS, Recovered CORRECT AS NOTED HEREON. Project no.: 16-161 EASEMENTS, ETC. AS THE RECORD MAY APPEAR. Released: CJULIANO Revision : 0 8. THIS BOUNDARY OPINION WAS MADE AND SURVEY MAP PREPARED FROM INFORMATION CONTAINED IN `71J,(y The information contained herein is the proprietary and confidential property of DEEDS AND MAPS OF RECORD, ALONG WITH PHYSICAL EVIDENCE LOCATED DURING THE FIELD SURVEY. David W. Juliano L.S. #08033 'V QC' I �� Juliano Associates, LLC. Reproductions, publication, distribution, or duplication in whole or in part requires the written permission of Juliano Associates. This Christopher S. Juliano L.S. #19725 document and copies thereof are valid only if they bear the original signature Engineers & Surveyors and embossed seal of the designated licensed professional. An alterations This document is valid onl if it bears an on inal si nature and DATE DESCRIPTION 9 p Y Y 9 9 405 Main Street (Yalesville) render this document null and void.©Copyright 2016 , All Rights Reserved. embossed seal of the designated licensed professional. Any Off GINAL SEAL Wallingford, Connecticut alterations render this document null and void. AND SIGNATURE REVISIONS (203) 265-1489 M:ISUBMITTED120161161002-1-O.DWG 6/7/2016 8:59AM CJ n s APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Applica ' s ere. ; BUILDING DEPARTMENT 1540 SULLIVAN AVENUE -/ 644-2511.ext. 230 Bldg:Permit# Date uIdding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$I,000=$15.00 Over$1,000= stket No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 6*jo1I ? /��b`irji7l2�YIC APPLICANT ADDRESS �Ca �n x / }/Y :S-10 e iJ of APPLICANT'S PHONE# OWNER C//Y 0* N O DRESS Cc O OWNER PHONE-'1) 7 C ESTIMATED COST$ l �zv IS THIS A CONTRACT COST? es No FEE ENCLOSED$ . � _ TYPE OF JOB: 3LI 3-3 �SOR•COS Installation Alteration/Addition/Repair 31 0 becoI Revised 03/05/10 i APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF Bun.DING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS Q. ASSEMBLY FUTM USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY Q STORAGE ADDRESS ❑ GARAGE O MDG;D USE CITY STATE ZIP (Other p1me'spxify) TYPE OF INSTALLATION/WIRING METHOD, SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBERS OF METERS NUMBERS.OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES, NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER`OFA/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE-SUBNIITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEARBYAPFLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK /5f y c CONTRACTORS LICENSE NO. TYr STATE . SIGNATURE OFAPPLICANT DATE NI dwcridons err e�oeoreeo� In dr cvcnt of a difaa,tx bctwnn the di.�vn and written dnunv«w the w�ron+ steel pcvel Due m bcel diFesences n bu0drg coda end Osm—end "d c sine m4bom these&r*x t ry need to6 siodiied by dm 6Ada m O0'�'with wch 6a codes ad K9�«x or sm aon�ieorsc OF Cabal Col tctiCut Q app* by Ahd6" A Iwo ••wd ljr d -- d�1o� r violMlon of .kb Nome WMAI S /1d�ns 154 Cfflkw Or. Gcdh Okidor.OWA Phone f CANOMW DoWn A J.LoMx D ft LeA04 Cabo Numbo Aibre WDT�!. 55° EXISTING RESIDENCE I 4 12' . ❑ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2' :3C 5T' �25-1/2" ROOF PITCH = 5 / 12 LINE OF CEDAR LATTICE SKIRTIW-z %00-A AROUND ENTIRE STRUCTURE 10' 24' (FORGN AREA) CUSTOM PLAN SCALE 1/4"=1'-O" All dvmem,ons ere approximate. In the event of a difference between the drawn and written clowns,ons, the written d,men"shall pevail. Xe to local differences in building codes and "latons,and specific site condmorw these drawings may reed to be modified by the builder to carroy with such local codes and regulations,or site conditions. Dedo by OF Cef*al Comtcticut Ullmod bd dTI111104M Ill •vbW=d ,I "hubils " Job N. WAA1.1.8 II /1cidNs b4 carr�aa�Dr. � ISNB booth uAncslMor,oiotA '�- PhW& f (SW 644-" EX15TING RE51IDENCE 16 II . 'r�F D'y'- A1Low Daft W/04 I Coma Nwim f i - DMftre WT poet GENERAL NOTES: l All Framin lumber to be 02 syp. or better, triated for ground contact, . + 10 11 12 12 unless noted otherwise. �i - rade All in- design values based on . 0 I gg g IRC 2OV3 One a Two Family l Dwelling Code IO' N III - Presum tive safe soil bearing capaciiy is 3000 PSF uno. C _IV I: Deck Framing :live load 60 P 5F I -I Design live load - 60 P5F.I I 9 I I G a G G _— %' - I "0 — s i �l All footings shall be 2 P.I.P. concrete, 2" deep, belled at i botto� ' I as noted unless pinned to sold oc _ (2) 2 x 10 beams, uno. T 5 10B . . . . . . . . . . . . . . . . . . . . . ��. . . . . . . . . . . '. . . . . . . . . . . . . . . . , . . . . . . a .�� 2 x 8 joists a 6" on center, a ` 12' on center 9 2' and 3' bays. 2 c JO S'S COL DNS 5, - 4 x 4 columns uno. rOR 10 3p N N_, =CRr,H 4RE4 - 2 x 8 house band lagged to house w/ min. 3/8x5 lag bolts 16' o.c.using 29-1/2" joist hanger connections - Provide joist hangers Q all flush frame conditions. LINE 0= CcC R L "ICE S+CIRi �G - Block joists 9 mid-span for spans '6C0 A of 4ROUNC, ENTIRE STRJCTJR= f or greater. - Screw fasten decking. - Verify all dimensions prior to construction. - Standard trim 0200. - Standard rail 0500 uno. LU/ 2x6 ripped rail trim - Stair "405-8 w/ cmu risers uno. Prepared by U.S. Structures, Inc 2112 W. Laburnum Ave. Richmond, VA 23227 Construction and Drafting STRU..TUR LFL_ N All lights 004eserved Structures, Unauthorized _ - - 5C4LE lia":I'-E duplication is a violation of a ll applicable laws. N dimensions ae fpio1"e6e In the emst of a Memice beaxem the drown and wvtacn clawaarw the written drama,sheN pews Due to local dFm a in 6Adins coda sd"Astsom r+d "dK at cordioorw theme diew.ef may need to be mod6ed by the buildo to comply wah%xb local coda.,d w9ilams a ate coNioora. Dsilp by OF / Central Comecibcut UwAabw drplostloa Y. rblrroa of 18RF /ERIFY ::Nl CFENING5 EEL _ U Job N�Jots IN AUA Df. -E -1E�GER DE I'z� —�-- 8 C2XBX121-211 8 IU TH -'Da- TICN4L LO.4D5 FR0`I _ 8outlf YAncbor.emu \ RIDG= BOARD R DGE E==1~ � f 10 -- ----\ 10 II _ _ —�•— _ II Dt* A J.Loyx Daft MA04 R0GE SUPPORT;WALL '1301-D Dwfe...rP1i,.b�� EXISTING; RE51DENCE �; �� � - - I- �,� �� 10RP �EILDDJu&T �RI<ET PORG1-1 NOTES: ; -15 RE GUR4D - -- --'I� -. -- - Roof Framing assumed total load e 42 P5F - - 5:12 gqable roof w/ roof tie-1n -- 15 - - — - — to ex' 5:12 roof -- - (2) P/4"x 12'%" LVL ridge beam -- -- oRB oc - Cathedral ceil(n exposed - rs R-145 1 t drywa cal Ing Finish ----- I x 6 PT fascia w/ 12" overhang IC' IOB 4 3/8" plyywood enclosed soffit-� per data IT 01319 - 8'-0" From TOD to bottom of soffit - Enclosed gable end (glass) Artistic Enclosure cambridge model 018 125 125 - Rid le support wall 01301-d w/ 15DR drywj 11 finish (include entire house wall). 12 Prepared by US. St Khm, Inc 2112 W. La6unn Ave. Ricirnond, VA 23227 Construction and Drafting ROOF PLAN Cc 4004 US. Stnxtures, Inc. II rights reserved. LlrteAkwized SCALE 1/4"=1'-0" duplication is a violabw of all applicable laws. SHINGLES UY 15'FELT 4 1/2" PLYWD., 12 R-19 INSULATION RAFTERS PER PLAN 8(�/ W/ BAFFLE 2x8 CLOSER DRYWALL CEILING FINISH PREFIN DRIP EDGE—� Wo FASCIA — 2x4 LOOKOUT gib"D.C. (2)2 x 8 ROOF BEAM hZTPI fl1MMMER W/ ENCLOSED SOFFIT 1 x 4 TOP t BOTTOM PLATES W/ 3/8" A/C PLYWD. ARTISTIC ENCLOSURE UNIT CAMBRIDGE MODEL '18 R-II INSULATION 2x450LE PLATE 3/4" PLYWOOp 5UB-FLOOR W/ SCREEN BE OW (2)2 x 8 JOIST sp i R-30 INSULATION W/ 3/8 PLYWOOD SOFFIT (6 x (o COLUMN W/ FINISH POUR TO TOP FOOTING P05T ANCHOR `t - 'd FIN GRADE a 10 12" SONOTUBE BELLED - a TO DIAMETER NOTED ON PLAN ' o SEE PLAN JL—AS T6.d .c wdcd any,, DATE: 12-3-2004 6 t6 001 cbm d 0am Wm OFFICE: CENTRAL CONNECTICUT c6w is of a bA*s project Duc to bul di6u n 6id„B codes .d icauleoar,.d * m that dwwm MYneed to PROJECT NAME: ING,4LLS 6mxVotd by the� oondii to ooeply*6 wch local oodes ad mpiob^ ot*e=xW= Duc to de nerved then duw+%cater, PROJECT NUMBER: 39-m34939 ka.ey ma be rwJed 6 vx on a fwli Mat SCALE: 3/4"=1'-0" ® 1994-4004 U.S. Strxtures, Inc. C 1 T ' YAP South Windsor BUILDING DEPARTMENT -' -_ , .0pir:s of the proP"s d arectad at ff Cf. t .. tottethar wlth amendments ai•d in 09111 �r tiled with plan and I agree ro comp wnnly .t H utldinq and state s and surh orders as ,%Sued OY the 8 Wir, UePar' -f during PETO at this apolcati and fin,: _ 'ante of a buli� Dw� i � (sflr o{M CN approved Su cti to th buildln[,tihatlion t t•` ` orders and ordinances r certsplRd SIItM. � food With Can01t1owo8M y r Clsrr. =�,V 0 L( APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPR v • _ w� 1540 SULLIVAN AVENUE Bldg. Permit# ~� 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: // Y $041,000=$15.00 l 7 -�r� 19-e DA Over$1,000= I Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT !ADDRESS /t S -I J G L O APPLICANT'S PHON # — 3-- _ OWNER LF N S •�DW Fq� �!OWN R AD. RESS l �c� .• L ?( , L c27 C 174 C 7 OWNER PHONE C * Jj ESTIMATED COST$ 3 G, rC1 IS THIS A CONTRACT/COST? ?es FEE ENCLOSED $ G• C. C:0 TYPE OF JOB: New Installation Alteration/Addition/Repair �g�1O02 Revised 03/05/10 L APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: 3-BATING FL-RESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. YDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) Gil DrCRIBE ALL HEATING EQUIPMEN (INCLUDING MAKE&MODEL NO.)/ �� GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) 1*245_ TYPE OF FUEL X_0IL-GPM 2 OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK �f�-- THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 71 CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICA T DATE Br—r,, LOT # 11* CK W Stitl; ll�.-ID HILL MATES" MAY 2p'-*157(aX;" qz-,VISEDs NOV-. 1972 co#vNEcricur L IGHr a P OWER -COAtPA NY I11G)ALI-f, 150.o 0 or li ZZ (4 N :b- z" Lor fo $00. Coto Qj ZZ 3 8. R. RANCH 5500 U L!"I 50'8ujLD1 Nc t wr iA%P- ,/Mr, L)L r-!'I Q� 3 1 IN. I E S. T F%LINI C,11 ES 000 Got Septic ,,rent 3 - 12 FEET 00 5.00 7 7- 0 ............ CARRIAGE DRIVE- y. 0 PLor PLAW FOR CARRIAGE DR. - SOUM. WINDSOR. 'CO (ALL"(* t..vtiRECT & SCALE .' 1 40 APR/L. leo 107, kllNG-;rjEWLArjj,).,-S VIOLATED: '93f AMIL 12 1973'A K0USF, 'UrjATM kp 91MV VIA' I'lltS API� WJ ZCNI.rW P-MULATI N /.-- — I�L' Qia .7 TWTSLI'ek j A m as E.-SHEEFfY US. 7034 .:It:-10Z; Sr SIMI(Y L. S. 701'. ed South Windsor BUILDING DEPARTMENT Iv I,ti: u_ _ TOti'tt1 Of SG$TH WIN: . eer:ili:;d that this plan and iswoifieations are .�_s vi the proposed building or alterations t, cI,d at L911 . t F,er wtth amendment sated in applicat!on .� ,i .vith pian and 1 agree to comply with all zan:-- ,:7:ng and sty la s t.nd such orders as shall I •.d 4Y the wilding Oepar< nt during penden, this applies on and tin::' ante of a buUGir. ,mit. s plan is approved s Meet to the condition tha -dsrs and ordlnances r gulatina building shall t, ,npllbd with. :ondttlonsliy Approved Thais filed with 8uliding Inspector C!a rt CERTIFICATION OF ZONING COMPLIANCE Proposed buifding(s), up-_(s) an.- �� structure(s) as sho on ihi::- aP^,,. �� he in conform,,-- ) k,' ;l currer. emu;. and ......ons "my = ,_ Date irp EW4coment Officer rV Query Next Previous Add Update Remove Ira. Screen [urrent � 2.02 81.34 PERMIT MAINTENMU 44 r• 2s, Classification d, Inspections • Permit 120011-1280621-IBI BUILDING PERMIT Serial No I 550731 Status IC I CLOSED Record Type ICI Permit Date 107/24/20011 [ O Date 112/31/20011 History �' 10 I Street Code I 991 117101 10194 I Site Addre5510194 CARRIAGE DRIVE I Parcel No. I 90 91 11 I Update by Iwil I Owner IINGALLS ROY J+CAROL A SURV I Update/Time 112/31/20011/110551 ��, contractor I I Master Permit I DI-I DI-I I Applicant TROY INGALLS I Struc Type 106 I GAR b CARP Address 1194 CARRIAGE DRIVE I Construction 156 I CONSTR 5B i I Use Group IR41 RESIDENT R4 Cty,St Zip (SOUTH WINDSOR ICTI 106074 I Est Value I 150001 Phone 1644-9846 I Permit Fee I 195.00� work Description C/O Fee I 5.001 'GARAGE 15' X 35' I Final Date I I i I Aff Cost I 01 I I Aff Fee Eng Fee I 0.001 'i 'd:I ul.k/v,hl.f.h'rr... ,vu. �,t7a:emrA.t-M.. �l�t-> .b►:rxo.. 3a .1sKt,-�e *:' 3Y424M i' , qy p uerexPrevious Add Ugdate Remove Table Screen Current 2.02 PERMIT MAINTENANCE INSPECTIONS Permit Type BUILDING PERMI Permit No. 2001 - 28062 - B Master Serial � 55073� ", Status I I Serial No I 178730� inspection / Approval Date Date By Approval Code Description Due completed Whom Code Time $ IB101 FINAL � 1108/27/20011 IGRM� ID I I � !�,, Comments �4JORK ON GARAGE OK-NEED SMOKES IN 3 BEDROOMS � Comments ADVISED BOB & HOMEOWNER � s' e T'7-MSS'-rnr 4 La`+el inT� a F a :.�° U Ms+s Fear.Fkr-T.. :.4r. r c�Ln.•tae*:1-IScosof... T®trbm-Mcrc�cft CaR... � < -- ♦ Ic��r'•Stafi Electric # /%5 �/`� APPLICATION FOR BUILDING PERMIT Plumbing# 194 Carriage Drive Date: S HVAC # Sprinkler# 31464 �; FINAL --- - -- --- --- — - Estimated Cost `�. AU) Buildingj� (' ' L,»- - --- - —-- -- - Permit Fee $ Affidavit COMPLETE RED BOXED AREAS Occupancy Fee $ /0 Adavit Endi g TYPE OR PRINT ONLY Eng. Insp. Fee $ Appr. for CO SIGN ON REVERSE SIDE Total Fee $ `1/S TO THE BUI NG DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant Rli-L4H•3M "tocation of Work IGq C=A&INAL O'L Lot No. Applicant's Address �'d"t C N M S-%,C-o LAO�:_ `Tel.# Y-oo- Ka-`1'�2 Town i3�_,a L4Q Zip 0(.1031 `Lic.# S�Src I K Owner I&JGALA-S Architect Owners Address 1'�1 N C:A-6A1 A C-r_ 01C Architect's Address Sot,yckA Ljlr►oso(L Zip c('0-1 Zip_ Sq. Ft. New Area: 1 st FI. 2nd Fl. 3rd Fl. Total New Area -Purpose of this permit S".3 rt, oQ21 City Water❑ Well[] Septic System❑ Sewer❑ Ins: HO Area Basement Garage Approved b Date ,�-7 fps Use Group Construction Type RwAssd 6/02 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of an etteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be ted the proper distance from all street lines,side yard lines,and required distances from all other zones and is k"te�d in which is t�ding a 'its use is allowed. \ Signed I hereby apply for a Certificate of Occy ncy for the work described in this application for the permit. Signed (/ L�2--L DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS i Inspection / Approval Date By Appl ' Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-31464-B 46,260 BO1 FOOTING 03/21/05 PJP A 10 12" PIERS B03 FRAMING (ROUGH) 04/04/05 PJP A TIE IN KNEE WALL ® EXISTING ROOF AND GABLE ADD CONNECTOR WLVLHEADER,CONNECT RAFTER SCISS E03 ROUGH 04/15/05 JFF A WITH ELECTRICIAN AND CONTRACTOR E03 ROUGH 04/18/05 PJP A B04 INSULATION 04/18/05 PJP A B10 FINAL 12/19/05 JFF A WITH OWNER **-19547-E 900 **-12509-H 1,500 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is TOWN OF SOUTH WINDSOR PERMIT# 1 BUILDING DEPARTMENT ZROV 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Building Insp or Application must be printed or typed FEE SCHEDULE Location of Job: 19q c�r �«� �Yive- $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT', APPLICANT ADDRESS eo APPLICANT PHONE# Z(p— �8 8 O '(O W N S F,q OWNER y OWNER ADDRESS ICIQ r . C- n(ad7 V i . E.. OWNER PHONE C = ESTIMATED COST$_[ �Qb•do w� x J IS THIS A CONTRACT COST? Yes _No �G �G FEE ENCLOSED$ ,op s TYPE OF JOB: OR-CO New Installation 4-Alteration/Addition/Repair Revised 4/01//2002 8/ 8 ► APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: AHEATING URESIDENTIAL IkA/C ❑COMMERCIAL ❑VENTILATION O INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑ WARM AIR 0 UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION:0 INSIDE❑OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 38r7V33 LT CONTRACTORS LICENSE NO. E STATE SIGNATURE OF APPLICANT DATE / DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Applic ere y: BUILDING DEPARTMENT / r/ �-VI PRO 1540 SULLIVAN AVENUE Bldg.Permit# 9 Z Li-A 644-2511 ext. 230 15aM ALU36Building In ctor Application must be printed or typed FEE SCHEDULE Location of Job: IRS( CAArZIA(xE Dn $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT )Zow dky W r i Q h,-{ APPLICANT ADDRESS 2,S }I avNCS sT IF �NF��cy CT 060 9-2 APPLICANT PHONE# 76 D G t y z-9 3 e O W N Se OWNER R cv t A Q 6t- 3-,tj t, j S OWNER ADDRESS 194 CA 4144 E 10 2 r OWNER PHONE y V t�G C ESTIMATED COST$ 900� s C� IS THIS A CONTRACT COST? V Yes _No FEE ENCLOSED$ 1��5 O�� TYPE OF JOB: �R C x New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A ®RESIDENTIAL BUILDING PERMIT APPLICATION? ❑YES ❑NO 0 BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE El EDUCATIONAL FUTURE USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE 0 GARAGE ADDRESS ❑MIXED USE (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION/WIRING METHOD Af (b1 SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? 0 YES O NO NUMBER OF LIGHT CIRCUITS ( NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES 3 NUMBER OF OUTLETS & NUMBER OF LIGHT FIXTURES _NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK 02 0 by .2 d QGG THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. i 90 a 7 F E1 eT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE B.17,IM LOT # 11 Ul FlAr WK4A.&ul 11SM11D HILL ESTATES" MAY RsvISEDs NOV,. 1972 CONNECT/cur LIGHr a POWER -CO-MPANY 150.00 LOT C. Z 0 Lor lo L:!j !2 cxl srINal-II - 3 B. R. RANCH 5500 122.501 MET 2F 14t. PUt wioE F.LAID il" n STO.iZ PORN 50'RUMOINC UAW i ' .1% -X (000 Got Septic irmL�IES. TRUCHES ULr*ri--' OF 1, J .3. 12*FEET C. M:N 00 k. 6 q.tl .00 CARRIAGE DRIVE p t k N, pLor PLAN FO.R ./ P Af N pR. SOU7H- rWPTM*hALLY %Kt7ECT SCALE . 40 VIOLATED: 1.4 MES r. LOCATED M*P .9%Wl M CNAIP ` 1973- 0 M Bu amTsui ' lv-lU$ APX- 11 ti CONNECT/CUT L /6HT B POWER COMPANY 150.0 0 LOT // u 0 c 3c y L or /o R, o � .O F 20./6 56 00 ra ~ p0 3 B R. RANCH s u-,1 IC 'h /2 4�,11^JEA.L FEET r i-ILL PER 22.0 20.I6 B DROUM. LAID li,: FT. WIDE T RENCI I r:._LED '..;i H WASHE+_ -RAVEL OR BR6KE.41 STONIE FOR A 50'8UILDING LINE O rTH OF 18 INCHES, TRENCHES ' /000 Go/ SeptIc rank �3 3-: 'A '_7 12 FE_ET C.0.' . MI^:. p 00 23g.2� 125.00 ` CARRIAGE DRIVE �s s 4`t+�.p.:•:"� P L O T P L A N FOR L / P M A /V CARRIAGE DR. — SOUTH WINDSOR, CON . SUi?�l�r.FIALLY ,_ ... ;aLCr � SCALE : / �� = 40 � MAR. /8, /973 NO ZONING RE3UL", P;t; V►CLATED: DAMES E. SHEEHY LS 7034 DAMES E. SHEEHY L.S. 7034 LOT j 11 CK W MiMms"',X1, r "SAND HILL ESTATES" MAY ,visED: -NOV,. 1972 .1; k 7 co#NEcrlcvr LIGHr a powf'lf co.MPA#r 150.00 ior t/ Q: 0 Lor fo ct O rxl sr/sIgLI 'Af 7rMtt 3 B.R. RANCH 550 %. 122.50 TZONLAI FUT 4 jjj 1 n ME 11 r %- TPEN . - � SO'BIRLDINC LINE N C;H E'S .)x (000 ULr-ri­- OF 1.1; INCHES. TRU -':)A.*:-:) 12*FEET C. r,%,j 3 Mi 00 0-0—L CARRIAGE DRIVE PL 0 r PL A M Fo R. M A N H- WR vavHl CARRIAGE DR. SOUr ' 5UPbT?A:f1ALLY t-OtiRECT. & SCAjE 1 40 -APRIL -ziidl*-llNC,.i.REG)jLATIQNS VIOLATED: 4/.4 Hous ATM j X CL Mvci .AMI 73"• W WATI TQW APX' NO "COW-RM JAM r E;.SHEEFfY L.S. 7034 ES 3. SILEMY L. S. 70 'ID 11159MIF�M 2 0 2111, 1 South Windsor BUILDING DEPARTMENT �a� Can�.�e -nl rlillctl that ln,s VI"n yna sy.�.:�•, -•Vie of the proposed building or Otter:,: 1 r t Stn eg logethe wi , am meats stated in application j filed wit pl n and I agree to comply with all Zer H 3ullding a st a laws and such orders as shah issued by the 13 ing Department during peed—nc Of this applicatio d final issuanot of a building. perm it. Signed .his plan it appro d su )eet to th ondltion that orders and urdinancea r ulating building shall be compiled with. Conditionally Approved These flied with 111Vng`lnspecto( C1`////����Clark t--�2° fat• _aL n0: 0?Y6 !'r�- andjor structure(s) Cr ) .I l�lf5 p,an appear(s) to be in cc;iioirnance with current South Windsor regulations. Variances and special exceptions may apply' Date ?/�� �. ` Zoning Enforcement Officer 1900482 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 07/20/2019 GIS ID: 17100194 FEE: 558.00 MUNIS APPLICATION# 201901248 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: SOUTHERN NEW ENGLAND WINDOWS LLC ADDRESS: 194 CARRIAGE DRIVE ADDRESS: 10 RESERVOIR ROAD OWNER: QUINONES NEREIDA 194 CARRIAGE DRIVE SMITHFIELD,RI 02917 DESCRIPTION OF WORK: INSTALL IO REPLACEMETN WINDOWS 4 DBL CASE 2 BAY SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 7/20/2019 12:47 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1900482 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 07/20/2019 GIS ID: 17100194 FEE: 558.00 MUNIS APPLICATION# 201901248 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: SOUTHERN NEW ENGLAND WINDOWS LLC ADDRESS: 194 CARRIAGE DRIVE ADDRESS: 10 RESERVOIR ROAD OWNER: QUINONES NEREIDA 194 CARRIAGE DRIVE SMITHFIELD,RI 02917 - DESCRIPTION OF WORK: INSTALL 10 REPLACEMETN WINDOWS 4 DBL CASE 2 BAY SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY TIIE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 7/20/2019 12:47 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1900148 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 03/22/2019 GIS ID: 17100194 FEE: 666.00 MUNIS APPLICATION# 201900473 BUILDING DESCRIPTION: APPLICANT . LOCATION NAME: SOUTHERN NEW ENGLAND WINDOWS LLC ADDRESS: 194 CARRIAGE DRIVE ADDRESS: 10 RESERVOIR ROAD OWNER: QUINONES NEREIDA 194 CARRIAGE DRIVE SMITHFIELD,RI 02917 DESCRIPTION OF WORK: INSTALL 5 REPLACE WINDOWS 1 GLIDING PATIO DOOR SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY E BUILDING DEPARTMENT. Z CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDI G OFFICIAL 3/22/2019 11:33 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1600417 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER BUILDING PERMIT DATE: 06/30/2016 GIS ID: 17100194 FEE: 240.00 MUNIS APPLICATION# 201600861 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: JULIANO'S POOLS ADDRESS: 194 CARRIAGE DRIVE ADDRESS: 321 TALCOTTVILLE ROAD OWNER: QUINONES NEREIDA VERNON ROCKVILLE,CT 06066 194 CARRIAGE DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: 20 X 40 INGROUND POOL WITH 4FT.HIGH SAFETY FENCE, SELF-CLOSING AND SELF-LATCHING GATE. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 6/30/2016 9:28 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1600342 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 08/24/2016 GIS ID: 17100194 FEE: 105.00 MUNIS APPLICATION# 201601150 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ANDREWS OIL CO. ADDRESS: 194 CARRIAGE DRIVE ADDRESS: 136 RYE STREET OWNER: _,QUINONES NEREIDA SOUTH WINDSOR,CT 06074 194 CARRIAGE DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REPLACING CONDENSER AND AIR HANDLER. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 8/24/2016 3:36 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1100103 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 04/13/11 GIS ID: 17100194 FEE: 60.00 MUNIS APPLICATION# 201100279 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: ANDREWS OIL CO. ADDRESS: 194 CARRIAGE DRIVE ADDRESS: 136 RYE STREET OWNER: SKULSKI EMIL W SOUTH WINDSOR,CT 06074 .194 CARRIAGE DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REPLACING LEAKING BOILER. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 4/13/201 l 11:31 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1600319 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 06/30/2016 GIS ID: 17100194 FEE: 30.00 MUNIS APPLICATION# 201600861 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: CARLSON&ROBBIATI ELECTRIC LLC ADDRESS: 194 CARRIAGE DRIVE ADDRESS: PO BOX 144 OWNER: QUINONES NEREIDA SOMERS,CT 06071. 194 CARRIAGE DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: BOND AND WIRE NEW INGROUND POOL. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 6/30/2016 9:29 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE