HomeMy WebLinkAbout19 LONG HILL RD i
APPLICATION FOR ELECTRICAL PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT
APPROVED, 1540 SULLIVAN AVENUE
644-2511 ext. 230 Bldg.Permit#
Date II Building Inspec ,
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 I
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT & (Q�j �cL10 r e
APPLICANT ADDRESSo
9047
APPLICANT'S PHONE#
O W N S F,q OWNER (ue
OWNER ADDRESS l °l s �;1 t t`-�) .
�
OWNER PHONE
- HONE
ESTIMATED COST$ y'So
"1 ` IS THIS A CONTRACT COST? Yes No
FEE ENCLOSED$
j TYPE OF JOB:
O. •CO�y�
R New Installation
Alteration/Addition/Repair
Revised 03/0500
APPLICATION FOR ELECTRICAL PERART(Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? 0 YES ❑ NO
RESIDENTIAL CURRENT USE AND OCCUPANCY
❑ BUSINESS
Cl ASSEMBLY FUTURE USE AND OCCUPANCY
O EDUCATIONAL;
0 INSTITUTIONAL ENGINEER'S NAME PHONE
O FACTORY
Q-STORAGE ADDRESS
❑ GARAGE
❑ MIXED USE CITY STATE ZIP
(Ocher please specify)
TYPE OF INSTALLATION/WIRING METHOD.
SIZE OF SERVICE SIZE OF MAIN CONDUCTORS
NUMBERS OF METERS NUMBERS OF DISCONNECTS AND RATINGSOA.�Q
NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? 01 YES ❑ NO
NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF.HEAT CIRCUITS
NUMBER"OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE-SUBMTITED.
DESCRIFITONOF WORK
G� ice ✓ c") A .C . S�s�-ew•
THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR-
MANCE OF SUCH WORK
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
a
N "
b
W
�•rY k Y.
200
f
r'
N
19 Long Hill Road
w*.
1 inch = 40 feet
APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT 1-7 V 0 2 Uto
AppR VE 1540 SULLIVAN AVENUE Bldg,Permit#
i� .t, 644-2511 ext. 230
Date Building Inspector
Application must be printed or typed
FEE SCHEDULE C
A
i Location of Job:
$041,000=$15.00 Over$1,000= T Street Lot No.
$15.00 per$1,000
or any fraction thereof signation Apt,No. ——
APPLICANT A0
APPLICANT ADD SS S S✓ -�� SW-
. o,• ,� G do
APPLICANT'S PHONE# )
OWNER 7iirL ti
OWN 8e4 OWNER ADD SS S, GtJ'
OWNER PHONE
C ESTIMATED CO �Sze Z 7OD.
V IS THIS A CONTRACT CUST7 es No
FEE ENCLOSED$ q 5
TYPE OF JOB:
�SQR.COS New Installation
Alteration/Addition/Repair
20 i-►.o os9 r7
Revised 03/05/10 .
APPLICATION FOR HVAC PERMIT(Continued from ievem side)
TYPE OF SYSTEM: TYPE OF BUILDING:
❑ G ❑ RESIDENTIAL
A/C ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRLAL
BEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC ❑ WARM AIR ❑ UNPT RADIANT.HEATER
EXISTING RADIATION A.DDTTIONAL RADIATION ''TOTAL RADIATION
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
ID,ESCRIBE ALL HEATING E UIPMENT(INCLUDING MAKE&MODEL NO.)
/!//• I
„/ S 'N J / � u✓T
GROSS HEATING CAPACITY QNPU-BTUR)- NET RATING(OUTPUT BTUH)�_
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY
❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPIV FNT(INCLUDING MAKE&MODEL NO.)
TONNAGE 3 9 COOLING CAPACITY(BTUH) 3/
VENTILATION
DESCRIBE ALL-AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION) .
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WPPH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE o23-1,2
INCORPORATIED
This letter grants permission for Degree Incorporated's Project Manager:
NAME o- slo-roQ
To apply for a permit for the following job:
Name Tv1, ye ti
Address_ cJ L o�1 l /Q�. So�T! GT
Customers Phone Number
Descriptionsr..�l,.�-;�,�,
Oa`
ost.
On behalf Degree Incorporated and Lawrenc W.Jordan, President, Degree Incorporated.
Signature
/,W/<ren)W.Jordan,President
HEA'r1NG,PIPING&COOLING UNLIMITED CONTRACTOR
LAWRENCE W JORDAN
160 OAR STREET
SUITE 508
GI ASTONBURY,CT 06033
LIC./REG NO. EFFECTIVE EXPIRES
HTG.0394791-S1 09/01/2016 08/31/2017
SIGNED
OX
l GO Oak Street Suite 508 Glastonbury CT OG033
P: 8GO.633.6 122 F: 860.633.6 124- www.decrreeheatingandcooling.com
DEGREE.. Load Short Form pate: May 23,2017
HES 1_ IQ * C QLING Entire House By: Jay Sharp
Project Information
For: Judy Harvey
19 Long Hill Rd., South Windsor,CT 06074
Design Information
Htg Clg Infiltration
Outside db("F) 2 88 Method Simplified
Inside db(°F) 70 70 Construction quality Average
Design TD('F) 68 18 Fireplaces 1 (Average)
Daily range - M
Inside humidity(%) 50 50
Moisture difference(gr/lb) 50 36
IM
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80 AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 2118 cfm Actual air flow 2118 cfm
Air flow factor 0.033 cfm/Btuh Air flow factor 0.061 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.94
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
OF) (Btuh) (Btuh) (cfm) (cfm)
1stfloor 1575 54550 31054 1809 1883
2nd floor 340 9319 3870 309 235
Entire House d 1915 63868 34924 2118 2118
Other equip loads 0 0
Equip. @ 0.93 RSM 32549
Latent cooling 2218
TOTALS 1915 63868 34767 2118 2118
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
+ wrightsoft' Como,1 Bum by wr1~17.0.19 RSU30182 2017-May-23 10:15:50
Pape 1 S:Wea1 LoadUudy Harvey.nip Cale=MJ8 Front Door faces: E
o Loads for Multiple Orientations Job:
DEGREE Date: May 23,2017,
N@ATFK- -ir G 0tING Entire House By: Jay Sharp
c:..e•.••.r.Cr
Project Information
For. Judy Harvey
19 Long Hill Rd.,South Windsor, CT 06074
Design Conditions
Location: Indoor: Heating Cooling
Hartford Brainard Field, CT, US Indoor temperature(°F) 70 70
Elevation: 20 ft Design TD(°F) 68 18
Latitude_ 42'N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 49.9 35.9
Dry bulb('F) 2 88 Infiltration:
Daily range(°F) - 21 ( M )
Wet bulb ('F) - 72
Wind speed(mph) 15.0 7.5
Front Door North Northeast East Southeast South Southwest West Northwest
Sensible Load(Btuh) 35632 34988 32549 35398 35766 34746 32201 34718
Latent Load(Btuh) 2218 2218 2218 2218 2218 2218 2218 2218
Total Load (Btuh) 37849 37205 34767 37616 37983 36964 34418 36935
Heating AVF(cfm) 2319 2277 2118 2304 2327 2261 2095 2259
Cooling AVF(cfm) 2319 2277 2118 2304 2327 2261 2095 2259
Building Orientation Cooling Load
40000
3000
2000
1000
0 }
N NE E SE S SW W NW
Direction Frart Door faces
Current Orientation: Front Door faces East
Highest Cooling Load: Front Door faces South
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
W rl htsot 2017-May-23 10:15 50
9 Comfort Builder by Wdghtsoft 17 0 19 RSU30182 Page 1
X--CK S\Heat LoadUudy Harvey rup Cak=MJ8 Front Door faces E
o Building Analysis sis Job:
DEGREE- Date: May 23,2017
Entire House By: Jay sharp
Project
For: Judy Harvey
19 Long Hill Rd.,South Windsor,CT 06074
Design Conditions
Location: Indoor: Heating Cooling
Hartford Brainard Field, CT, US Indoor temperature(T) 70 70
Elevation: 20 ft Design TD(°F) 68 18
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 49.9 35.9
Dry bulb(°F) 2 88 Infiltration:
Daily range(°F) - 21 ( M ) Method Simplified
Wet bulb(°F) - 72 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
•
Component Btuhlf? Btuh %of load
Walls 5.8 9706 15.2 Wall Infiltration
Glazing 43.8 7464 11.7
Doors 26.5 1114 1.7
Ceilings 14.4 22678 35.5 Glazing`
Floors 7.5 11869 18.6 Other Floors
Infiltration 5.9 11037 17.3
Ducts 0 0
Piping 0 0
Humidification 0 0 Ceilings
Ventilation 0 0 g
Adjustments 0
Total 1 63868 100.0
• •
Component Btuhfif Btuh %of load
Walls 1.9 3176 9.1 Wall Irtgo, ns
Glazing 43.9 7482 21.4 �
Doors 11.4 479 1.4 Floors
Ceilings 11.2 17592 50.4
Floors 2.0 3177 9.1 Gazing_,.,
Infiltration 0.7 1328 3.8
Ducts 0 0
Ventilation 0 0r
Internal gains 1690 4.8
Blower 0 0
Adjustments 0 Oailirlgs
Total 34924 100.0
Latent Cooling Load=2218 Btuh
Overall U-value=0.212 BtutVfe°F
Data entries checked.
. W riehtSoft' comfort 13 pdr by wdghtsoft 17.0.19 RSU30182 2017 May-23 10:15: 1
Page
1
S:Weat LoadUudy Harvey.rup cak=MJ8 Front Door faces: E
Component Constructions
DEGREE pate: May23,zo,T
}t l' t 1 1 ti Entire House By: Jay Sharp
Project Information
For: Judy Harvey
19 Long Hill Rd.,South Windsor,CT 06074
Design Conditions
Location: Indoor: Heating Cooling
Hartford Brainard Field,CT, US Indoortemperature(°F) 70 70
Elevation: 20 ft Design TD(T) 68 18
Latitude: 42'N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 49.9 35.9
Dry bulb(°F) 2 88 Infiltration:
Daily range('F) - 21 ( M ) Method Simplified
Wet bulb(T) - 72 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
f? Btuhlft;°F WF/Btuh Stuh/V Btuh MAW Btuh
Walls
12D-Osw:Frm wall,vnl ext,r-15 cav ins,1/2"gypsum board int fish, n 125 0.086 15.0 5.85 730 1.91 239
2"x4"wood frm,16"o.c.stud a 160 0.086 15.0 5.85 936 1.91 306
s 114 0.086 15.0 5.85 664 1.91 217
w 160 0.086 15.0 5.85 936 1.91 306
all 558 0.086 15.0 5.85 3265 1.91 1068
12D-Osw:Fnn wall,vnl ext,1/2"wood shth,r-15 cav ins,1/2"gypsum n 320 0.086 15.0 5.85 1871 1.91 612
board int fnsh,2"x4"wood frm,16"o.c.stud a 237 0.086 15.0 5.85 1383 1.91 453
s 285 0.086 15.0 5.85 1667 1.91 545
w 260 0.086 15.0 5.85 1520 1.91 498
all 1102 0.086 15.0 5.85 6442 1.91 2108
Partitions
(none)
Windows
1 D-c2ob:2 glazing,dr outr,air gas,mtl/w brk frm mat,dr innr,1/4" n 11 0.650 0 44.2 497 24.7 277
gap, 1/8"thk;6.67 ft head ht n 40 0.650 0 44.2 1768 24.7 986
e 23 0.650 0 44.2 994 74.8 1683
s 11 0.650 0 44.2 497 40.6 457
s 54 0.650 0 44.2 2387 40.6 2195
w 20 0.650 0 44.2 884 74.8 1496
all 159 0.650 0 44.2 7028 44.6 7095
1 D-c2ow:2 glazing,dr outr,air gas,wd frm mat,dr innr, 1/4"gap, 1/8" s 11 0.570 0 38.8 436 34.5 388
thk;6.67 ft head ht
Doors
11 DO:Door,wd sc type a 21 0.390 0 26.5 557 11.4 240
s 21 0.390 0 26.5 557 11.4 240
all 42 0.390 0 26.5 1114 11.4 479
Ceilings
16B-19ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" 340 0.049 19.0 3.33 1133 2.58 879
gypsum board int fish
Wr htsoft 2017-May-23 10:15:51
�"''. Comfort Budder by Wrightsoft 17.0.19 RSU30182 pap 1
AM SAHeat LoadUudy Harvey.rup Cale=MA Front Door faces: E
C part ceiling,:C part ceiling,hrd wd fir fish,frm fir,6'thkns,1/2" 1235 0.257 1.0 17.4 21545 13.5 16713
gypsum board int fish
Floors
19A-0bswp:Part floor,hrd wd fir fnsh,frm fir,6"thkns 1575 0.295 0 7.54 11869 2.02 3177
4 wrightSoft' Comfort Builder by Wrightsoft 17.0.19 RSU30182 2017-May-23 10:15:51
Page 2
ACCh S:Weat LoadUudy Harvey.rup Cak=MJ8 Front Door faces: E
a
Component Constructions J
DEGREE May 23,zo,�
i f "1 1"(' A < ow r:r, 1st floor By: Jay Sharp
Project • •
For: Judy Harvey
19 Long Hill Rd.,South Windsor,CT 06074
Design Conditions
Location: Indoor: Heating Cooling
Hartford Brainard Field,CT, US Indoor temperature(°F) 70 70
Elevation: 20 ft Design TD(°F) 68 18
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 49.9 35.9
Dry bulb(°F) 2 88 Infiltration:
Daily range(°F) - 21 ( M ) Method Simplified
Wet bulb(°F) - 72 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions or Area u-value Insul R Htg HTM Loss Clg HTM Gain
W BWh/ftVF fP=F/Btuh Btuh/ft' Btuh BLh/ft' Btuh
Walls
12D-Osw:Fnn wall,vnl ext,1/2"wood shth,r-15 cav ins, 1/2"gypsum n 320 0.086 15.0 5.85 1871 1.91 612
board int fish,2"x4'wood frm,16"o.c.stud a 237 0.086 15.0 5.85 1383 1.91 453
s 285 0.086 15.0 5.85 1667 1.91 545
w 260 0.086 15.0 5.85 1520 1.91 498
all 1102 0.086 15.0 5.85 6442 1.91 2108
Partitions
(none)
Windows
1 D-c2ob:2 glazing,dr outr,air gas,and/w brk frm mat,dr innr,1/4" n 40 0.650 0 44.2 1768 24.7 986
gap, 1/8"thk;6.67 it head ht a 23 0.650 0 44.2 994 74.8 1683
s 54 0.650 0 44.2 2387 40.6 2195
w 20 0.650 0 44.2 884 74.8 1496
all 137 0.650 0 44.2 6033 46.6 6360
Doors
11 DO:Door,wd sc type a 21 0.390 0 26.5 557 11.4 240
s 21 0.390 0 26.5 557 11.4 240
all 42 0.390 0 26.5 1114 11.4 479
Ceilings
C part ceiling,:C part ceiling,hrd wd flr fnsh,frm flr,6"thkns,1/2" 1235 0.257 1.0 17.4 21545 13.5 16713
gypsum board int fish
Floors
19A-Obswp:Part floor,hrd wd flr fnsh,frm flr,6"thkns 1575 0.295 0 7.54 11869 2.02 3177
' 2017 May-23 1 wrightsoft Comfort Builder by Wrightsoft 17.0.19 RSU30182 Page 3
ACC S1Heat LoadUudy Harvey.rup Calc=MJ8 Front Door faces: E
Component Constructions Job:
D E G R E E, Date: May 23,2017
ti i A I I":t. k (0 t 11 1,, 2nd floor By: Jay Sharp
Project Inf• •
For: Judy Harvey
19 Long Hill Rd.,South Windsor,CT 06074
Design Conditions
Location: Indoor: Heating Cooling
Hartford Brainard Field,CT, US Indoor temperature(T) 70 70
Elevation: 20 ft Design TD(T) 68 18
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 49.9 35.9
Dry bulb(T) 2 88 Infiltration:
Daily range(°F) - 21 ( M ) Method Simplified
Wet bulb( F) - 72 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft' Btuh/fti`F ft'=F/Btuh Btuh/ft' Btuh Btuh/ft' Btuh
Walls
12D-Osw:Frm wall,vnl ext,r-15 cav ins, 112"gypsum board int fish, n 125 0.086 15.0 5.85 730 1.91 239
2"x4"wood frm, 16"o.c.stud a 160 0.086 15.0 5.85 936 1.91 306
s 114 0.086 15.0 5.85 664 1.91 217
w 160 0.086 15.0 5.85 936 1.91 306
all 558 0.086 15.0 5.85 3265 1.91 1068
Partitions
(none)
Windows
1D-c2ob:2 glazing,dr outr,air gas,mtl/w brk frm mat,dr innr,1/4" n 11 0.650 0 44.2 497 24.7 277
gap, 1/8"thk;6.67 ft head ht s 11 0.650 0 44.2 497 40.6 457
all 23 0.650 0 44.2 994 32.7 735
1D-c2ow:2 glazing,cir outr,air gas,wd frm mat,cir innr,1/4"gap, 1/8" s 11 0.570 0 38.8 436 34.5 388
thk;6,67 ft head ht
Doors
(none)
Ceilings
1613-19ad:Attic ceiling,asphalt shingles roof mat,r-19 coil ins, 1/2" 340 0.049 19.0 3.33 1133 2.58 879
gypsum board int fish
Floors
(none)
2017-May-23 10:15:51
wrightsoR' Comfort Builder by Wrightsoft 17.0.19 RSU30182
Page 4
S:\Heat LoadUudy Harvey.rup Cale=MA Front Door faces: E
a Project Summary Job:
DEGREE _ � rY Date: May 23,2ot;
HEATING R COOLING
Entire House By: Jay Sharp
Project • •
For. Judy Harvey
19 Long Hill Rd.,South Windsor,CT 06074
Notes:
Design Information
Weather. Hartford Brainard Field,CT,US
Winter Design Conditions Summer Design Conditions
Outside db 2 °F Outside db 88 °F
Inside db 70 °F Inside db 70 °F
Design TD 68 °F Design TD 18 °F
Daily range M
Relative humidity 50 %
Moisture difference 36 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 63868 Btuh Structure 34924 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 63868 Btuh Use manufacturer's data n
Rate/swing multiplier 0.93
Infiltration Equipment sensible load 32549 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 2218 Btuh
Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1915 1915 Equipment latent load 2218 Btuh
Volume(fN) 15320 15320
Air changes/hour 0.58 0.26 Equipment total load 34767 Btuh
Equiv.AVF(cfm) 148 66 Req.total capacity at 0.70 SHR 3.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80 AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 2118 cfm Actual air flow 2118 cfm
Air flow factor 0.033 cfm/Btuh Air flow factor 0.061 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.94
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
+ wrightsoft- Comfort Builder by Wdghtsoft 17.0.19 RSU30182 zon May-231oPasgee I
ACO►.SAHeat LoadUudy Harvey.rup Cale=MJ8 Front Door faces: E
a AED Assessment Job:
DECREE Date: May 23,2017
UN a--Co I Entire House By: Jay snag
Project
For: Judy Harvey Information
19 Long Hill Rd.,South Windsor,CT 06074
Design C• • •
Location: Indoor: Heating Cooling
Hartford Brainard Field,CT, US Indoor temperature(°F) 70 70
Elevation: 20 ft Design TD(°F) 68 18
Latitude: 42'N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 49.9 35.9
Dry bub(T) 2 88 Infiltration:
Daily range(°F) - 21 ( M )
Wet bub("F) - 72
Wind speed(mph) 15.0 7.5
Test for • - • Exposure Diversity
Hourly 9 Glazin Load
i
12
11,000
1Q
91000
8,
7,
6,
5,000
4,
3,000
z
o —+-- - r-- - -- - +
8 9 10 11 12 13 14 15 16 17 18 19 20
Har d Eby
/FWIy A-p AED 1-d
Maximum hourly glazing load exceeds average by 26.7%.
House has adequate exposure diversity(AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2017-May-23 10:15:51
ti wrightsof't` comfort Builder by Wrightsoft 17.0.19 RSU30182 Page
A& SAHeat LoadUudy Harvey.rup Calc=MJ8 Front Door faces: E
DEGREE° Right-J®Worksheet Job:
Entire House Date: May23,2017
P1EA,ItN!. n7141��,
By: Jay Sharp
1 Room name Entire House 1st floor
2 Exposed wall 234.0 ft 160.0 ft
3 Room height 8.0 It d 8.0 It heat/cool
4 Room dimensions 35.0 x 45.0 It
5 Room area 1915.0 ft' 1575.0 W
Ty Construction U-value Or I HTM I Area (fr) I Load I Area (fP) I Load I
number (BtuhffP-'F) (Btuhfir) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cod W Gross plS Heat Gross WP/S Heat Cod
6 Vy 12D-Osw 0.086 n 5.85 1.91 136 125 730 239 0 0 0 0
r G 1llc2ob 0.650 n 4410 24.66 11 0 497 277 0 0 0 0
Vy 12D-Osw 0.086 n 5.85 1.91 360 320 1871 612 360 320 1871 612
L-G 1D-c2ob 0.650 n 44.20 24.66 40 0 1768 986 40 0 1768 986
11 W 1213-0sw 0.086 a 5.85 1.91 160 160 936 306 0 0 0 0
w 12D-0sw 0.086 a 5.85 1.91 280 237 1383 453 280 237 13a3 453
G 1Dc2ob 0.650 a 44.20 74.79 23 0 994 1683 23 0 994 1683
D 1111130 0.390 a 26.52 11.41 21 21 557 240 21 21 557 240
12D-0sw 0.086 s 5.85 1.91 136 114 664 217 0 0 0 0
113-c2ob 0.650 s 44.20 40.65 11 0 497 457 0 0 0 0
ID-c2ow 0.570 s 38.76 34.46 11 0 436 388 0 0 0 0
1213-0sw 0.086 s 5.85 1.91 360 285 1667 545 360 285 1667 545
1D-c2ob 0.650 s 44.20 40.65 54 0 2387 2195 54 0 2387 2195
D 11130 0.390 s 26.52 11.41 21 21 557 240 21 21 557 240
W 1213-0sw 0.086 w 5.85 1.91 160 160 936 306 0 0 0 0
1-6
y 12D-0sw 0.086 w 5.85 1.91 280 260 1520 498 280 260 1520 498
1-f 1D-c2ob 0.650 w 44.20 74.79 20 0 884 1496 20 0 8" 1496
C 16B-19ad 0.049 - 3.33 2.58 340 340 1133 879 0 0 0 0
C C Dart ceiling. 0.257 17.45 13.53 1235 1235 21545 16713 1235 1235 21545 16713
F 19A-0bswp 0.295 - 7.54 2.02 1575 1575 11869 3177 1575 1575 11869 3177
61 c)AED excursion 01 -151
Envelope loss/gain 1 52831 31906 1 1 47003 28M
12 a) Infiltration 11037 1328 7547 908
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 3 690 2 460
Applianceslother 1000 1000
Subtotal(lines 6 to 13) 63MB 34924 54550 31054
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 63868 34924 54550 31054
15 Dud loads 0% 0% 0 0 -0% 0% 0 0
Total room oad 10541
An r"uiredl(cfm) I I I 6211618I 2118I I ( 51809I 45M31883
Calculations aaoroved by ACCA to meet all requirements of Manual J 8th Ed.
i wrightsotft- Mort Builder by Wrightsoft 17.0.19 RSU30182 2017 May-23 tOP 5:5;
�� S:Weat LoadUudy Harvey.rup Calc=MA Front Door faces: E Page
DEGREE° Right-JO Worksheet
Entire House Date: May23,2017
:..sN . �1
By: Jay Sharp
1 Room name 2nd floor
2 Exposed wall 74.0 It
3 Room height 8.0 It heat/cool
4 Room dimensions 20.0 x 17.0 ft
5 Room area 340.0 ft'
Ty I Construction U-value Or I HTM I Area (ff) I Load I Area I Load I
number (BtuhffY-'F) (BtuhffP) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heal Cool Gross NIPIS Heat Cool
6 V�/ 12D-0sw 0.086 n 5.85 1.91 136 125 730 239
L ( 1Dt2ob 0.650 n 4420 24.66 11 0 497 277
12D-0sw 0.086 n 5.85 1.91 0 0 0 0
1Dc2ob 0.650 n 44.20 24.66 0 0 0 0
11 W 12D-0sw 0.086 a 5.85 1.91 160 160 936 306
1213-0sw 0.086 a 5.85 1.91 0 0 0 0
1O-c2ob 0.650 a 44.20 74.79 0 0 0 0
D 11130 0.390 a 26.52 11.41 0 0 0 0
12D-0sw 0.086 s 5.85 1.91 136 114 664 217
1D-c2ob 0.650 s 44.20 40.65 11 0 497 457
1D-c2ow 0.570 s 38.76 34.46 11 0 436 388
VL�G1213-0sw 0.086 s 5.85 1.91 0 0 0 0
1 Dc2ob 0.650 s 44.20 40.65 0 0 0 0
D 11DO 0.390 s 26.52 11AI 0 0 0 0
W 1213-0sw 0.086 w 5.85 1.91 160 160 936 306
Vy 12D-0sw 0.086 w 5.85 1.91 0 0 0 0
' G 1 Dc2ob 0.650 w 44.20 74.79 0 0 0 0
C 16B-19ad 0.049 - 3.33 2.58 340 340 1133 879
C C Dart ceiling. 0.257 17.45 13.53 0 0 0 0
F 19A-0bswp 0.295 - 7.54 2.02 0 0 0 0
61 c)AED excursion 1 151
Envelope lossfgain 1 58281 3220
12 a) Infiltration 3490 420
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 1 230
Appliancestother 0
Subtotal(lines 6 to 13) 9319 3870
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 9319 3870
15 Duct loads -0% 0% 0 0
TotIr al room load required(cfm) I I I 9309I 3235I I I I I
Ai
Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed.
' wrightsOft' Mort Builder by Wrightsoft 17.0.19 RSU30182 2017 May-231 Pa:5 ge 2
S:Weat LoadUudy Harvey.rup Calc=MA Front Door faces: E
Electric # APPLICATION FOR BUILDING PERMIT
Plumbing# - - I
-
HVAC# 19 Tong Hill Road Date: /DAD/��O/O
Sprinkler# 1000519 Estimated Cost $ 37, 58fd
FINAL APPROVALS Permit Fee $ .Sq(a —
Building COMPLETE RED BOXED AREAS Occupancy Fee $
Engineering TYPE OF PRINT ONLY Eng. Insp. Fee $
Affidavit ► SIGN ON REVERSE SIDE t
Appr.forCO. • 1-
Total F yv�� $
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant (,YD/U--rIOnT Locationof Work Lot No.
Applicant's Address 7 /Vec,),Aea rh c rled oS aHe-1 Tel S/ 6qco x 15
Town 9lb ank .0 h N Zip /a-?Dj' Lic.#
Owner iu-a- 1-i? lV aL -y etw Architect
—T
Owner's Address 19LVr)q H ( Architect's Address
`S. W i rn d SO r, Zip Dw D 744 — __ Zip
Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd Fl. Total New Area
Purpose of this permit CI tiL B-/ V/ Jl .S'/GL"'4 35 Z SQ
City Water❑ Well 0 Septic System 0 Sewer 0
Ins: HO SP Area Basement Garage
Approved by e l o p Use Group Construction Type
M A-14 4/Z��►3 v7p\00\�1D 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which
/this building and its use is allowed.
Signedo
I hereby apply for a Certificate of Occupancy for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
i
INSPECTION FIELD SHEET 09/23/13
1 Printed by Peart, Dayshell 12 59 05 1
INSPECTION: 35673 FINAL PERMIT:
STATUS:
APPLICATION: 201001390
LOC: 19 LONG HILL ROAD
SOUTH WINDSOR
PROPERTY ID: 54600019
OWNER: HARVEY JUDITH A
CONTRACTOR:
REQUEST BY:
PROJ DESC: REPALCEMENT OF VINYL SIDING 35 5 SQUARE
WORK ORDER:
INSPECTOR: ROSE RESULT: N/A
REQUESTED: 04/18/11 PRIORITY
SCHEDULED: 04/18/11 PM COMPLETED: 09/23/13
UNPAID FEES 00 Date Time
MILEAGE 00 TIME: TRAVEL ONSITE
COMMENTS
JUDY @ 860-573-2971
ALL INSPECTIONS:
INSPECTED INSPECTOR RESULT INSP DESCRIPTION
05/24/13 DOUG PASS BO10 FINAL
BUILDING PERMIT.
DSTATE OF CONNEC,'IICUT
WORKERS COMPENSATION COMMISSION
Sou,h winds T I3g �din�Permit Affidavit for Property Owners or Sole Proprietors
Qv}`D�NG DEPAR 1� (Conn.Gen.Stat.§31-286b)
Property located at_ Lct IIL,az� o S • ;,,y(�
In the town of
I
Name of building permit applicant: n4e�Qo lY�s1K
Please check one:
1._I am the owner of the above property.
2.-L,A am the sole proprietor of a business.
2A.Name of business_ ri p t 9 tj () ,,rA to D,�4 Q's.JU C
2B.Federal Employer Identification Number(FEIN)_(o,S'—q( -� ?o
...........................................
........................:.
Pursuant to§31-2M,"a ro •.owner or sole proprietor[who]intends to act as a general.....
contractor or principal employer"may provide either certificate of workers'compensation
insurance or a"sworn notarized affidavit... stating that he will require proof of workers'
compensation insurance for all those employed on the job site in accordance with this chapter."
Please che:71
1. not intend to net as a general contractor or principal employer.
[Sign and stop here]
Signs p leant
2._I intend to act as.a general contractor or principal employer.Applicant must either
provide a certificate of workers'compensation insurance or sign the affidavit
below.
.............................................................................................................
:...... ——
Affidavit
I hereby swear and attest that I will rc4uire proof of workers'compensation insurance for every
contractor,subcoattactor,or other worker before hclshe engages in work on the above property in
accordance with the Vorkere Compensation Act(Chapter 558).
I understand that.pursuant to§31-275 C.G.S.,officers of a corporation and partners in a
partnership may elect to be excluded frorri coverage by filing a waiver with the appropriate
District Office;and that a sole proprietor of a business is not required t6have coverage unless he
files his intent to accept coverage.
Signature of applicant
Subscribed and sworn to before me this day of 11200
(Notary Public!Commissioner of the Superior Court)
INSPECTION REPORT
1 Page 5
7yv V), - ire•-(
Was a more in-depth investigation of leaching system conducted? no Y/N
What were the results?
Is there an expansion/repair area available? x Likely Not Likely Unknown
Were there any conditions observed which might limit a repair?(wetlands,ledge outcrops, streams,etc.)
test holes will determine
DIAGRAM OF TANK AND LEACHING SYSTEM LOCATION (ties from permanent structures)
P N
C �
T
y sLoP
(S jut 2v
r
I I �jAa,oG�� 2 53
N
t �
!f/ N
Andrew Gilbert /
Inspector's Name (printed or typed) Prep a s' ignature
Profession: Installer LIC. No. 3425
This form is a result of a Connecticut Environmental Health Association Committee consisting of members of the State
Dept.of Public Health, Local Sanitarians, Licensed Installers, CT Sewage Disposal Association, CT Association of
Realtors and the Home Inspection Industry
19 Long Hill Road South Windsor.xls W�-k
Electric # AP & 0� BUILDING PERMIT
Plumbing#
HVAC# UMIX D �� -l� � 0
Sprinkler# 900271 Estimated Cost $ Od
FINAL APPROVALS EPAP AMit Fee $
Building COMPLETE RED BOXEffXftt Occupancy Fee $ �(Z
Engineering TYPE OFF PRINT ONLY Eng. Insp. Fee $
Affidavit Appr.forCO. SIGN ON REVERSE SIDE / Total Fee 160
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant 2�t PA)2V RD Ia Su, Location of Work 14 L o,)j rl o Lot No.
Applicant's Address 4)L ►+. vKag(t Tel # %6,) F - Y6 4 7
Town , a.f-t 0 Zip C0617 a Lic.# 11I'r- Q<L g1?41
Owner u104 Architect
Owner's Address 1 Lp�1c 11:a Q n Architect's Address
Zip Zip
Sq. Ft.New Area: 1 st FI. 2nd FI. 3rd FI. � �Area
Purpose of this permit c 0-i (
G
City Water 0 Well Lae'O' Septic System 0000' Sewe t
Ins: HO SP Cert. Area Basement Garage
Approved by Date Use Groupc� Construction Type
om00-lm Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any a plans4444 or specifications of the Building for which this
permit is asked,and agree that this building is to be local the proper dist from all street lines,side yard lines,and required
distances from all other zones and is locaRITE
9THISLINE
lowed.
Sign -
I hereby apply for a Certificatehis application for the permit.
Sign
INSPECTION COMMENTS
Electric # 1 g LongPkli LAjt(2k FOR BUILDING PERMIT
Plumbing#
HVAC# 14000404 Date:
S rinkler#
p Estimated Cost $ /, oV°•
FINAL APPROVALS
Permit Fee $
Building _ COMPLETE RED BOXED AREAS .
Occupancy Fee $ /o
Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit
Appr.forCO. SIGN ON REVERSE SIDE -4 Total Fee $ to ,
TO THE BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ CaSh
The undersigned hereby applies to do work according to the following:
Applicant Location of Work Lot No.
Applicant's fTel # yio
Town ult zip b Lic.# 7D 333
Owner Architect
Owner's Address L&A4 11 Architect's Address
Zip Wtoo) Zip
Sq. Ft.New Area: 1 st FI. 2nd F✓I. f 3rd FI. Total New Area
Purpose of this permit �r1 r aaY �LA f I S M du
City Water 'Z1 Well J Septic System Sewer J ,2a t y o!1 a
Ins: HO V SP Cert. p . Area Base�ignt Garage
Approved by Date 0 I Use Groupj_��ction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building and its use is allowed.
Signed -- - - -
I hereby apply for a Certificate of Occupancy for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
r
a
INSPECTION FIELD SHEET 04/12/22
Printed by Middleton, Morgan 16 07 47
INSPECTION: 69774 FINAL PERMIT:
STATUS:
APPLICATION: 201401105
LOC: 19 LONG HILL ROAD
SOUTH WINDSOR
PROPERTY ID: 54600019
OWNER: HARVEY JUDITH A
CONTRACTOR:
REQUEST BY:
PROJ DESC: REPAIR WORK TO EXISTING DECK.
WORK ORDER:
INSPECTOR: DOUG RESULT: PASS
REQUESTED: 09/15/14 PRIORITY:
SCHEDULED: 09/19/14 02 30 COMPLETED: 09/15/14
UNPAID FEES: 00 Date Time
MILEAGE: 00 TIME: TRAVEL ONSITE
COMMENTS:
ALEX ® 1-860-428-6603
ALL INSPECTIONS:
INSPECTED INSPECTOR RESULT INSP DESCRIPTION
09/02/14 DOUG PASS B001 FOOTING
ALEX 0 860-428-6603
B002 FOUNDATION
B003 FRAMING (ROUGH)
E003 ELECTRIC ROUGH
1000519 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 10/13/10
GIS ID:54600019 FEE: 596.00
MUNIS APPLICATION# 201001390 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: PHILLIPS HOME SOLUTIONS ADDRESS: °: 19 LONG HILL ROAD
ADDRESS: 427 NEW KARNER ROAD' OWNER: HARVEY JUDITH A
ALBANY,NY 12205 ;, 19 LONG HILL ROAD
SOUTH WINDSOR,CT 06074
F
DESCRIPTION OF WORK: REPALCEMENT OF VINYL SIDING 35.5 SQUARE '
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
10/13/2010 11:19 AM THE FEE ABOVE INCLUDES A SO.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1000519 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 10/13/10
GIS ID:54600019 FEE: 596.00
MUNIS APPLICATION# 201001390 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: PHILLIPS HOME SOLUTIONS ADDRESS: ` 19 LONG HILL ROAD
ADDRESS: 427 NEW KARNER ROAD OWNER: HARVEY JUDITH A
ALBANY,NY 12205 ! ;V 19 LONG HILL ROAD
- SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: REPALCEMENT OF VINYL SIDING 35.5 SQUARE +
. T
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
I0/13/2010 11:13 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
14000404 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 08/13/2014
GIS ID: 54600019 FEE: 30.00
MUNIS APPLICATION# 201401105 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: KKS CONSTRUCTIOV ADDRESS: '19.LONG HILL ROAD
ADDRESS: 17 SUNRISE DRIVE `l ? OWNER: .•.,.HARVEY JUDITH A
GLASTONBURY,CT 06033 19 LONG HILL ROAD
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: REPAIR:WORK TO EXISTING DECK. r
r`_ •yti,:w: •h,
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITII THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
8/132014 4:10 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1700206 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 05/25/2017
GIS ID: 54600019 FEE: 195.00
MUNIS APPLICATION# 201700597 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: DEGREE INC. ADDRESS: 19 LONG HILL ROAD
ADDRESS: 160 OAK STREET SUITE 508 OWNER: HARVEY JUDITH A
GLASTONBURY,CT 06033 19 LONG HILL ROAD
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: INSTALLATION OF A MITSUBISHI DUCTLESS MINI SPLIT HEAT PUMP
UNIT.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/25/2017 3:28 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1700156 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER ELECTRICAL PERMIT
DATE: 05/25/2017
GIS ID: 54600019 FEE: 15.00
MUNIS APPLICATION# 201700597 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: SALONE ELECTRIC,INC. ADDRESS: 19,LONG HILL ROAD
ADDRESS: P.O. BOX 972 OWNER: HARVEY JUDITH A
ROCKY HILL,CT 06067 19 LONG HILL ROAD
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: WIRE NEW SPLIT A/C SYSTEM.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
5/25/2017 3:52 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE