Loading...
HomeMy WebLinkAbout189 BERRY PATCH BUILDING 7 Electric # 19 u t APPLICATION FOR BUILDING PERMIT Plumbing# It -77 189 Berry Patch (Building 7) Date: HVAC # / 2(0 3 7 Sprinkler## S 1 31218 -- Estimated Cost $22 000.00 FINAL PR _ _ Buildin 1 !o1 Permit Fee $ 5 5 O �" �° COMPLETE RED BOXED AREAS Occupancy Fee $ O Enginee ng TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavi Appr. for C z w SIGN ON REVERSE SIDE Total Fee $ 3`yO TO THE B ILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following: Applicant The Metro Construction Corp. Location of Work 189 Berry Patch Lot No. 2L Applicant's Address 6 Executive Drive, Suite 100 Tel.# 860-674-5640 Town Farmington, CT Zip 06032 Lic.# MC0.900434 Owner_x:y Patch II Associates L.P. Architect Associated Architects Owner's Address 6 Executive Drive, Suite 100 Architect's Address 16 Spring Lane Farnunc ton, Cr Zip 06032 Farmington, Cr Zip 06032 Sq. Ft. New Area: 1st FI. 896 2nd Fl. --- 3rd FI. --- Total New Area 896 Purpose of this permit New Construction - multiple single family affordable dwelling City Water[X Well❑ Septic System❑ SewerM Ins: HO SP Cert. Area Basement Garage Approved by Date Use Group Construction Type R""d 6102 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. THE METRO CONSTRUCTIGN CORP. Signed ter P. nnZPresid(jal I hereby apply for a Certificate of Occupancy for the work described in this appl ion or rmit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- ' **-31218-B 22,000 B01 FOOTING 04/07/05 PJP A B02 FOUNDATION 04/21/05 PJP A BO1 FOOTING 04/25/05 PJP A B02 FOUNDATION 04/28/05 PJP A DRAINS WATERPROOFING P02 UNDERGROUND 05/27/05 PJP A EAST P02 UNDERGROUND 06/06/05 PJP A MID P02 UNDERGROUND 06/08/05 PJP A WEST PO4 GAS TEST 12/08/05 PJP A B03 FRAMING (ROUGH) 01/06/06 PJP A E03 ROUGH O1/06/06 PJP A P03 ROUGH O1/06/06 PJP A PRESSURE TEST B04 INSULATION O1/23/06 PJP A B10 FINAL 06/14/06 JFF A WITH DAN **-1513-S 2,000 **-12637-H 6,000 **-11777-P 5,000 **-19341-E 2,700 • III BUILDING INSPECTION DEPARTMENT TOWN of SOUTH WINDSOR, CONNECTICUT C E R T I 1-'C A e 11� � x C�T P A N C Y ZONE: , « t",` June 14 2006 This is to certify that-'1ff9 ER Tf6?ERECT, un-' gretperinit No. 31218 conformd subsGhntie l"y >.to tht: �a uirei��nts :of th1. Connecticut 9 .Yy:...N..n..92�. £. >`ac.R'Q Basic Building cdde�:and'_th •ioniny rpguf&tiions—dethe IT61w ,6f cl ""'n3 i.s;hereby°ap ctVed £C C tpaNc}+ ds$ rioicated below South Windsor a T ay",`•a? �.•=°p,°0`s": � d`:8'`ro�waWFf<;:e�3a'R'ia. �` js.x*a�; Approved for Oc u'Panc ^°�a.-ML -S gad �Y DWEL '1 <G-,' tiTI ; Use Group R3 H { :.$ �..,:,. =F; •'b'S' £' i »:` r.' Constr. Type SB ,. Notice If this cent iicatei8, }o�G;;oas�zbyed, Wauplicate should be obtainedi mediate y*-lito�thi Bukldiilg6Department lka Any change or extensi"6n of the u e hgre`In approved requires a new certificakexof occupancy. DEPARTMENT DECISION APPLICATION FOR I- VAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT � 3 7 ADntt(�VF 1540 SULLIVAN AVENUE ' S44-2511 ext. 23U Bldg.Permit# �2M?005 3 la r� Date wilding*or Application must be printed or typed FEE SCHEDULE Location of Job: 1A 9 Berry Patch 2 L $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or an::fraction thereof Tenant Designation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS. 56 Depot Street Broad Brook, Cr 06016 APPLICANT PHONE# . (860) 623-1991 0* S Fq OWNER _Berry Patch II Associates Limited Partnership OWNER ADDRESS 6 Executive Drive, Suite 100 ` - Farmington, Cr. 06032 O " 0 F, OWNER?HONE (860) 674-5641 ` ESTIMATED COST$6 ,0 0 0 . 0 0 IS THIS A CONTRACT COST? %Yes _No FEE ENCLOSED$ 9 0 . 0 0 4. TYPE OF JOB: .SpR,CU X New Instal'ation Alter ation/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERNUT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: ®HEATING $)(RESIDENTIAL 50 A/C ❑COMMERCIAL ®VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC 0(WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Magic Pak MJN 5IHWCT43A 9y Armstrong GROSS HEATING CAPACITY(LNTPUT BTUH)51 ,000 NET RATING(OUTPUT—BTUH) 40,000 TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑ INSIDEQ OUTSIDE CAPACITY ® GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF P e r TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) P 1 a n s DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) & Specs TONNAGE 2 COOLING CAPACITY(BTUH) 24.0 0 0 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFm) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 303755 S-1 CT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE �� —� DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT S/3 APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.�Pe�rmFIit#9 Ut 2 — ID gnspeo tlpplicatiun mttst be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 St-reef No. Berry Patch , Over$1,000= Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. . APPLICANT Thomas L. Jacquel c/o Allstate Fire Sprinkler, Inc. APPLICANT ADDRESS. P.O. Box 2350 Hartford, CT 06146 ---- APPLICANT PHONE# (860) 246-7711 �QW N SF� OWNER Berry Patch II Associates Limited -Partnership < OWNER ADDRESS 6 Mcecutive Drive Suite 100 Fanninc#ai, CT 06032 Q 'P OWNER PHONE (860) ,674-5641 ESTIMATED COST$2 ,0 0 0.0 0 `�• IS THIS A CONTRACT COST? X Yes No r FEE ENCLOSED$.3 0,0 00,0 0 SOR,Cps TYPE OF JOB: X New Installation Alteration/Addition/Repair R—i-4 A1A1//Innl APPLICATION FOR SPRINRLER PERtiIIT (Continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES M RESIDENTIAL ❑BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑?MERCANTILE ❑EDUCATIONAL CURRENT USE AND OCCUPANCY ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ❑ STORAGE ❑ GARAGE ENGINEER'S NAME David R- Thcapson PHONE(860) 246-7711 ❑MIXED USE (Other please specify) ADDRESS P.O. Box 2350 Cry Hartford STATE Cr ZIP 06146 KIND OF INSTALLATION SIZE OF MAIN DRAIN 1 1 f 4" WATER PRESSURE AT STREET(PSI) ARE SPRINKLER HEADS ALTERED? 3 YES ❑NO IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES W NO IF YES, CHECK ALL THAT APPLY: ❑ FIRE ❑BOOSTER ❑ OTHER ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? W YES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP NSA PSI DESCRIPTION OF WORK New fire sprinkler system in two bedroan unit THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. F10590 Fire Sprinkler cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT O 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Bm ding Inspector Application must be printed or typed FEE SCHEDULE Location of Job: FTe:nant Berry Patch 2Z $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt.No. APPLICANT Fahrenheit Mechanical Services Inc. APPLICANT ADDRESS 56 Depot Street Broad Brook, CT 06016 APPLICANT PHONE# (860) 623-1991 D W N S k. OWNER Berry Patch II Associates Limited Partnership < OWNER ADDRESS 6 Executive Drive, Suite 100 Farmington, Cr 06032 s ,r, OWNER PHONE (860) 674-5641 O ESTIMATED COST$ 51 000.00 IS THIS A CONTRACT COST? x Yes _No �G FEE ENCLOSED$ 75.00 �` CO TYPE OF JOB: O R X New Installation _Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR PLUMBING PERiNUT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME PHONE ❑ STORAGE ❑ GARAGE ADDRESS ❑1V=D USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4" NO. OF TOILETS 1 STYLE ElOngated NO.URINALS N/A STYLE N/A NO.OF BATHTUBS NO.OF SHOWERS 1 NO.OF LAVATORIES 1 NO.OF CONDUCTORS SIZE NO. OF STACKS 1 SIZE 3 AREA OF ROOF Back NO.OF CATCH BASINS N/A NO. OF FLOOR DRAINS 1 Kitchen NO. OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑ YES 92 NO SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4 Weil Mclain WATER HEATER: TYPE Indirect rect MANUFACTURER P/US 120 DESCRIPTION OF WORK I'HE UNDERSIGNED HEREBY APPLIES FOR A PERNIIT TO PERFORM THE WORK DESCRiBED Al COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P-1 00204480 P-1 CT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT / DATE ��� 9' oy DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT �3 CAPPROVE , , 1540 SULLIVAN AVENUE 232004 644-2511 ext. 230 Bldg. Permit# Date uilding lnsp r 3 d S Application must be printed or typed FEE SCHEDULE Location of Job: 189 Berry Patch 2L $0-$1,000=$I5.00 Street No. Street Over$1,000= Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT J-Electric APPLICANT ADDRESS 8 Sanrieo Drive Manchester, Cr 06040 APPLICANT PHONE# (860) 645-9891 ----------- p W Pl S Fq OWNER Berry Patch II Associates Limited Partnership OWNER ADDRESS 6 Exec.�utive Drive, Suite 100 Fes, CP 06032 OWNERPHONE (860) 674-5641 ESTIMATED COST$ 2,700.00 IS THIS A CONTRACT COST? X Yes —No �! 4� FEE ENCLOSED$ 45.00 �QS.OR.Cw., TYPE OF JOB: XNew Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A 91 RESIDENTIAL BUILDING PERMIT APPLICATION? ❑YES ❑NO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY Residence ❑EDUCATIONAL ❑ INSTITUTIONAL ❑FACTORY ENGINEER'S NAME EA3/CJL Mxj,neering PHONE - (860) 257-3968 ❑ STORAGE 203 Briarwood Court ❑ GARAGE ADDRESS O MIXED USE CITY Rocky Hill STATE Cr ZIP 06067 (Other please specify) TYPE OF INSTALLATION/WIRRING METHOD NMC SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? O YES ❑NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8 NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23 NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS 1 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Interior wiring of apartment to include outlets, switches and their cover plates. Wiring of appliances and HVAC unit. Install light fixtures. Install 100 amp breaker panel. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 123580 Ir1 Cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT _ �/�/--�r DATE