Loading...
HomeMy WebLinkAbout18-20 LAKEWOOD (PINTAIL CIR) APPLICATION FOR PLUMBING PERNIIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074(PHONE) 860-644-2511 EXT. 230 PERMIT NUMBER: DEPARTMENT DECISION APPLICATI $EBY: APPROVE BLDG.PERMIT NUMBER: DATE OR P � R LOCATION OF WORK: I n t 1 ('C It, APPLICANT• OWNER: TYPE OF STRUCT : Morn C,nc( Pbr- Ournb�y--�+j ,n Sc- ^^ ❑NEW BUILDING NAME:?e-\r_r Cz My�t. NAME: 1 A f.J ❑ADDITION PHONE NUMBER:$e d_ �o y.3 _p 97q PH 1 7 ONE NUMBER: (AC)- 5 " 5?OO( ❑MCSTING BUII.DLNG ADDRESS:q,3 I Nf ej SIR ! ADDRESS:,-20 D I n 4d1 l C r<<e TYPE OF USE: A/�N nn(! LA�, C-lr- o(nu(-16_L RESIDENTIAL o COMMERCIAL PLUMBING INFO&VATION: FURTIIER DESCRIPTION OF WORT(: TYPE OF INSTALLATION: —5�-�T- -'-1�.�- /io t eC NO.OF TOMETS: STYLE: NO.OF BATHTUBS:_ leah NO.OF SHOWERS: NO.OF LAVATORIES: NO,OF CATCH BASINS: NO.OF FLOOR DRAINS: ARE TOILET COMPARTMENTS VENTH.ATED TO OUTER AIR BY WINDOW? OYES DNO ESTIMATED COST: S SIZE OF WINDOW: SIZE OF DUCTS: SEWER OR SEPTIC TANK: FEE ENCLOSED:S SIZE OF WATER PIPING AND RISER: WATER HEATER: TYPE MANUFACTURER FEE SCHEDULE:SIS PER S1,000 OF THE ESTL'FiATED COST. ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS SI.00 OVER. (.26 CENT EDUCATIONAL FEE INCLUDED AS PART OF THE PERMIT FEE) THE UNDERSIGNED NEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.: E- STATE: 10 3112020 SIGNATURE OF APPLICANT: DATE: C�Q—�cx 9U y s APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 (PHONE) 860-644-2511 EXT. 230 DEPART ECISfiNq PERMIT NUMBER: APP td E Y: -700 9 S I APPRO BLDG.PERMIT NUMBER: 9" DAT F CTOR LOCATION OF WORK: 9 PI o+d( I C( (' Sl)+h (A)i n(150 r (2 1 APPLICANT: OWNER: TYPE OF STRUCTURE: ,�y�p aa Cl NEW BUILDING I NAME: \I[l�s11 I I P. 1 ❑ADDITION NAME:�1 G I I U �U1L.Il..c_ e,(V��S Y 1 'd �`S PHONE NUMBER:�0-Q512 Qk-C 0 PHONE NUM�BER:2bo `1!)b V� NXISTING BUILDING ADDRESS�p b�( �� 1��`Qr( �AvDDRESS:_/(, Pl(�a(l C�L-r Lo clCs, C�o bC�Q h � LI+n lil lsoc TYPE OF USE: e�ttrSIDENTIAL ❑COMMERCIAL HVAC INFORMATION: FURTHER DESCRIPTION OF WORK: TYPE OF SYSTEM: )�ATING ❑A/C rQeDl �Mkni - En e C Q 6 o P_i GCS HEATING: TOTAL HEAT LOSS(BTUH) °F (HEAT LOSS SHEET REQUIRED) DESCRIBE ALL HEATING EQUIPMENT(INCLUDE MAKE AND MODEL NO.): 1 IESTIMATED COST:A 16,ow AIR CONDITIONING: n c DESIGN TEMP:OUTSIDE OF INSIDE OF DIFFERENCE F° FEE ENCLOSED: TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET REQUIRED) 1 332 DESCRIBE ALL COOLING EQUPMENT(INCLUDE MAKE AND MODEL NO.): FEE SCHEDULE:$18 PER$1,000 OF THE ESTIMATED COST. ROUND UP TO THE NEXT THOUSAND ONCE THE PROJECT IS$1.00 OVER. (.26 CENT EDUCATIONAL FEE INCLUDED AS PART OF THE PERMIT FEE) THE UNDERSIGNED NEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOMANCE OF SUCH WORK. CONTRACTORS LICENSE NO.:GXW39 TYPE:2 STATE: C,i nn SIGNATURE OF APPLICANT: DATE: `t laa�la �10117 3'� p12031s . .. . • �bSMt 5345�tr� • • :. .'. .��" . •, •,. . • . �.�•. H'O'M'E S'E RV I'C�E�S - I°Hoo 6351' To Whom This May Concern: Aiello Home Services Authorized Alesha Fillmore, Stephen Birch, Joe Boissonneault, Robert Bilodeau, Lorie Metivier, Stacy Dlubac, Cindy Nicewicz, Tim Lynch, Mike Loscialpo, Matt Rose, James Fullana, Jesse Conway, Keith Miller, Wilson Cloukey, and Scott Matyskiela to pull permits for our company for any Plumbing, Heating, or Air Conditioning replacement(s) or new Installation(s). If you have any questions please call our office at 860-292-2600. This Letter is for a permit for the property located at: &LptllAaA 0-k( aufl/-) wjn�sa(" Home Owner: V A� � Permit Fee Amount: $ ' Sincerely, Michael Jezouit DEPARTMENTSTATE OF CONNECTICUT , CONSUMER PROTECTION President HEATING,PIPING&COOLING UNUNUTED CONTRACTOR MICHAEL R JEZOUIT PO BOX 548 WINDSOR LOCKS,CT 06096-0548 LIC./REG NO. EFFECTIVE EXPIRES HTG.0303032-S1 01/2017 08/31/2018 SIGNED Heating • Air Cond t on ng • PI mb ng • E ectr cal• Heating Oil 3 Energy SOluto S Right J® Mobile Retort Job: 539096 wrightsoft 9 p Date: 9/22/2017 Entire House By: Jesse Conway Aiello Home Services 600 Old County Circle,Windsor Locks,CT 06096 Phone:860-218-5130 Fax:860-292-2690 Email:jessec@goaiello.com Web:www.helloaiello.com License:P1-203350,... Project • • For: Vijay Desai 20 Pintail Circle,South Windsor,CT 06074 Phone:860-869-1589 Design Conditions Location: Indoor: Heating Cooling Hartford, CT, US Indoor temperature(°F) 70 75 Elevation: 180 ft Design TD(°F) 62 13 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 26.4 26.4 Dry bulb(°F) 8 88 Infiltration: Dailyrange(°F) - 21 ( M ) Method Simplified V1kt bulb(°F) - 72 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Component Btuh& Btuh %of load Walls 23.1 32509 56.5 Glazing 35.6 5691 9.9 Doors 24.3 781 1.4 Kii abm Ceilings 3.1 1712 3.0 Floors 6.9 3872 6.7 Infiltration 4.6 6384 11.1 Vws Ducts 6573 11.4 Piping 0 0 � Humidification 0 0 aaarg Ventilation 0 0 Adjustments 0 Total 1 57523 100.0 Component Btuh/ft2 Btuh %of load Walls 5.3 7532 29.0 Irterr>��� Glazing 50.9 8142 31.4 Doors 9.5 306 1.2 Wil Ceilings 2.3 1316 5.1 DLcts Floors 1.5 825 3.2 Infiltration 0.4 553 2.1 Ducts 3950 15.2 Ventilation 0 0 Irfiltra Internal gains 3320 12.8 Rocs Blower 0 0 lirgs Adjustments 0 Ga&g CdW Total 1 25944 100.0 Latent Cooling Load=2041 Btuh Overall U-value=0.212 Btuh/ft2-°F Data entries checked. .� wrightsoft` 2017-Sep-2211:14:51 '1• Right-Suite®Universal 2017 17.0.28 Right J®Mobile Page 1 \wstmp\09f5e6e9.94ea-42b0•b19f-4c4882587705.rup Calc=MJ8 Front Door faces: N . 9 Project Summary Job: 639096 wr i htsoft' Date: 9/22/2017 Entire House By: Jesse Conway Aiello Home Services 600 Old County Circle,Windsor Locks,CT 06096 Phone:860-218-5130 Fax:860-292-2690 Email:lessec@goaiello.com Web:www.helloaiello.com License:P1-2033% Project • • For: v1'ay Desai 2 t Pintail Circle,South Windsor,CT 06074 Phone:860-869-1589 Notes: Design Information Weather: Hartford,CT,US Winter Design Conditions Summer Design Conditions Outside db 8 OF Outside db 88 OF Inside db 70 OF Inside db 75 OF Design TD 62 OF Design TD 13 OF Daily range M Relative humidity 50 % Moisture difference 26 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 50950 Btuh Structure 21994 Btuh Ducts 6573 Btuh Ducts 3950 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 57523 Btuh Use manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25944 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1478 Btuh Ducts 562 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft� 1088 108EF Equipment latent load 2041 Btuh Volume 7616 7616 Air changes/hour 0.74 0.30 Equipment Total Load(Sen+Lat) 27985 Btuh Equiv.AVF(cfm) 94 38 Req.total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 1157 cfm Actual air flow 1157 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 Boldrtalia values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofC 2017-Sep-2211:14:51 g Right-Suite®Universal 2017 17.0.28 Right A Mobile Page 1 ...1wstmp109f5e6e9-94ea-42b0-b19f-4c4882587705.rup Calc-MJ8 Front Door faces: N - +-wrightsoft Right-M Worksheet Job: 539096 Entire House Date: 9/22/2017 • Aiello Home Services By: Jesse Conway 600 Old County Circle,Windsor Locks,CT 06096 Phone:860.218-5130 Fax:860-292-2690 Email:jessec@goaiello.com Web:www.helloajello.com License:P1-203350,... 1 Room name Entire House First Fl" 2 Exposed wag 200.0 ft 100.0 It 3 Room height 8.0 ft d 8.0 It heat/cool 4 Room dimensions 16.0 x 34.0 ft 5 Room area 1088.0 ft, 544.0 f N Ty I Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft i•F) (Btuh/ft� I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1qJ 128-Osw 0.097 n 6.05 2.14 128 116 699 247 0 0 0 0 �G 1D-c2ov 0.570 n 35.57 18.30 13 0 445 229 0 0 0 0 15CO-0.2 0.800 n 41.34 8.88 128 116 4775 1025 128 116 4775 1025 1 D-c2ov 0.570 n 35.57 18.30 13 0 445 229 13 0 445 229 11 Vjl 126-Osw 0.097 a 6.05 2.14 272 245 1480 523 0 0 0 0 G, 1D-e2ov 0.570 a 35.57 62.18 28 0 978 1710 0 0 0 0 V)I 15CO-0-2 0.800 a 41.31 8.86 272 245 10101 2167 272 245 10101 2167 �G 1D-c2ov 0.570 a 35.57 62.18 28 0 978 1710 28 0 978 1710 1R/ 126-Osw 0.097 s 6.05 2.14 128 118 699 247 0 0 0 0 L-G 1D-c2ov 0.570 s 35.57 33.79 13 0 445 422 0 0 0 0 15C0-42 0.800 s 41.34 8.88 128 116 4775 1025 128 116 4775 1025 1D-c2ov 0.570 s 35.57 33.79 13 0 445 422 13 0 445 422 yl 1213-Osw 0.097 w 6.05 2.14 272 245 1480 523 0 0 0 0 1-G 1D-c2ov 0.570 w 35.57 62.18 28 0 978 1710 0 0 0 0 Vjl 15C0�2 0.800 w 40.01 8.35 272 212 8499 1773 272 212 8499 1773 ;L_pG 1D-c2ov 0.570 w 35.57 62.18 28 0 978 1710 28 0 978 1710 11 DO 0.390 w 24.34 9.54 32 32 781 306 32 32 781 306 C 1613-19ad 0.049 - 3.06 2.35 560 560 1712 1316 16 16 49 38 F 19A-Obvcp 0.295 - 6.92 1.47 5" 544 3762 802 544 544 3762 802 F 19A-Obvcp 0.295 - 6.92 1.47 16 16 111 24 0 0 0 0 61 c)AED excursion 01 1 10 Envelope loss/gain 1 44%5 18120 1 1 35588 11208 12 a) Infiltration 6384 553 2736 237 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants C 230 4 920 4 920 Appliances/other 2400 2400 Subtotal(lines 6 to 13) W9501 21 M 38324 14765 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 50950 21994 38324 14765 15 Duct loads 13% 18% 6573 3950 13% 18% 4944 2652 L 1 Total room load 5 Air required(Um) I I I 1157 I 21�I I I 43268 I 174 Calculations aoDroved by ACCA to meet all reauirements of Manual J 8th Ed 414- wr1ghtsoTt' 2017-Sep-2211:14:51 Rig ht-Sufle®Universal 2017 17.0.28 Right J®Mobile Page 1 %wstmp109f5e6e9-94ea.42bO-b19f-4c4882587705.rup Calc-MJS Front Door faces: N +wrightsoft• Right-M Worksheet Job: 539096 Entire House Date: 9/22/2017 • Aiello Home Services By: Jesse Conway 600 Old County Circle,Windsor Locks,CT 06096 Phone:860-218-5130 Fax:860-292-2690 Email:jessec@goaiello.com Web:www.helloaiello.com License:P7-203350,... 1 Room name Second Floor 2 Exposed wall 100.0 It 3 Room height 8.0 ft heat/cool 4 Room dimensions 16.0 x 34.0 ft 5 Room area 644.0 ft' Ty Construction U-value Or HTM Area Ift') Load Area Load number (Btuh/ftz'F) (Btuh/ft2 I or perimeter (ft) I (Btuh) I or perimeter I I Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y! 1213.Osw 0.097 n 6.05 2.14 128 116 699 247 �G 113-c2ov 0.570 n 35.57 18.30 13 0 445 229 V)I 15C0.0-2 0.800 n 41.34 8.88 0 0 0 0 L G 1D-c2ov 0.570 n 35.57 18.30 0 0 0 0 11 Vjf 1213-0sw 0.097 a 6.05 2.14 272 245 1480 523 I� 113-c2ov 0.570 a 35.57 62.18 28 0 978 1710 y/ 15CO-0-2 0.800 a 41.31 8.86 0 0 0 0 �---G 1D-c2ov 0.570 a 35.57 62.18 0 0 0 0 t-G12B-0sw 0.097 s 6.05 2.14 128 116 699 247 1D-c2ov 0.570 a 35.57 33.79 13 0 445 422 y/ 15CO-0-2 0.800 s 41.34 8.88 0 0 0 0 Ili 1D•c2ov 0.570 s 35.57 33.79 0 0 0 0 yl 12B-Osw 0.097 w 8.05 2.14 272 245 1480 523 L-G 1 D-c2ov 0.570 w 35.57 62.18 28 0 978 1710 VI! 15CO-0-2 0.800 w 40.01 8.35 0 0 0 0 �Cp, 1D-c2ov 0.570 w 35.57 62.18 0 0 0 0 11 DO 0.390 w 24.34 9.54 0 0 0 0 C 1613-19ad 0.049 - 3.06 2.35 644 544 1663 1278 F 19A-Obvcp 0.295 6.92 1.47 0 0 0 0 F 19A-Obvcp 0.295 - 6.92 1.47 16 16 ill 24 61 c)AED excursion 10 Envelope loss/gain 1 8977 6913 12 a) Infiltration 3648 316 b) Room ventilation 0 0 13 Internal gains: Occupants 230 0 0 Appliances/other 0 Subtotal pines 6 to 13) 12626 7229 Less external bad 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 12626 7229 15 Dud loads 13% 18% 1629 1298 TotI I Airal room�uireal(dm) I I I 1428 I 38201 I I I I Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft• 2017-Sep-2211:14:51 Right-Suite®Universal 2017 17.0.28 Right AD Mobile Page 2 %wstmp109f5e6e9-94ea-t2b0-019f-4c4882587705.rup Calc-MJ8 Front Door faces: N 9 Component Constructions Job: 639096 wri htsoft P Date: 9/22/2017 Entire House By: Jesse Conway Aiello Home Services 600 Old County Circle,Windsor Locks,CT 06096 Phone:860-218-5130 Fax:860-292-2690 Email:jessec@goaiello.com Web:www.helloaiello.com License:P1-203350,... Project Information For: Vijay Desai 20 Pintail Circle, South Windsor,CT 06074 Phone: 860-869-1589 Design Conditions Location: Indoor: Heating Cooling Hartford,CT, US Indoor temperature(°F) 70 75 Elevation: 180 ft Design TD (T) 62 13 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gNlb) 26.4 26.4 Dry bulb(°F) 8 88 Infiltration: Daily range(T) - 21 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain tr BbhlW-`F fF-°F/BEh BbhN Btuh BthAF Btuh Walls 12B-Osw:Frm wall,vnl ext,r-11 cav ins,1/2"gypsum board int n 116 0.097 11.0 6.05 699 2.14 247 fish,2"x4"wood frm,16"o.c.stud a 245 0.097 11.0 6.05 1480 2.14 523 s 116 0.097 11.0 6.05 699 2.14 247 w 245 0.097 11.0 6.05 1480 2.14 523 all 720 0.097 11.0 6.05 4358 2.14 1540 15CO-0-2:Bg wall,heavy dry or light damp soil,concrete wall,4"thk n 116 0.304 0 41.3 4775 8.88 1025 e 245 0.304 0 41.3 10101 8.86 2167 s 116 0.304 0 41.3 4775 8.88 1025 w 212 0.304 0 40.0 8499 8.35 1773 all 688 0.304 0 40.9 28151 8.71 5992 Partitions (none) Windows 1 D-c2ov:2 glazing,clr outr,air gas,vnl frrn mat,dr innr,1/4"gap, n 13 0.570 0 35.6 445 18.3 229 1/8"thk;foreground=green grass(0.23);6.67 ft head ht n 13 0.570 0 35.6 445 18.3 229 e 28 0.570 0 35.6 978 62.2 1710 e 28 0.570 0 35.6 978 62.2 1710 s 13 0.570 0 35.6 445 33.8 422 s 13 0.570 0 35.6 445 33.8 422 w 28 0.570 0 35.6 978 62.2 1710 w 28 0.570 0 35.6 978 62.2 1710 all 160 0.570 0 35.6 5691 50.9 8142 Doors 11 DO:Door,wd sc type w 32 0.390 0 24.3 781 9.54 306 Ceilings 16B-19ad:Attic ceiling,asphalt shingles roof mat,r-19 oeil ins, 1/2" 560 0.049 19.0 3.06 1712 2.35 1316 gypsum board int fish wrightsOft 2017-Sep 22 11 Page RigM-Suite®Universal 2017 17.0.28 Right J®Mobile Page 1 \wstmp109f5e6e9.94ea-42b0-b19f-4c4882587705.rup Calc=MJ8 Front Door faces: N Floors •19A-Obvcp:Flr floor,wd fir,1"thkns,carpet fir fish,leaky bsmt ovr 544 0.295 0 6.92 3762 1.47 802 16 0.295 0 6.92 111 1.47 24 all 560 0.295 0 6.92 3872 1.47 825 Wrl htsOft' 2017-Sep-22 11:14:52 9 Right-Suite®Universal 2017 17.0.28 Right A Mobile Page 2 %wstmpO 5e8e394ea-42b0-b19f4c4882587705.rup Calc=MJ8 Front Door faces: N 9 AED Assessment Job: 639096 wri htsoft Date: 9/22/2017 Entire House By: Jesse Conway Aiello Home Services 600 Old County Circle,Windsor Locks,CT 06096 Phone:860-218-5130 Fax:860-292-2690 Email:jessec@goaiello.com Web:www.helloaiello.com License:P1-203350,... Project • • For: Vijay Desai 20 Pintail Circle, South Windsor,CT 06074 Phone:860-869-1589 Design Conditions Location: Indoor: Heating Cooling Hartford, CT, US Indoor temperature(T) 70 75 Elevation: 180 ft Design TD(°F) 62 13 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gNlb) 26.4 26.4 Dry bulb(T) 8 88 Infiltration: Dailyrange('F) - 21 ( M ) Wet bu lb(°F) - 72 Wind speed (mph) 15.0 7.5 Test for • • Exposure Diversity Hourly Glazing Load 11,00 10,00 9,00 8,00 7,00 6,00 5,00 4,00 3,00 2,00 1,00 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day / Fb iy X Average i P®Ilmt Maximum hourly glazing load exceeds average by 21.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 1 wri hltsOt 2017-Sep-2211:14:52 n►. 9 Right-suite®Universal 2017 17.0.28 Right J®Mobile Page 1 ACCk ...\wstmp109f5e6e9-94ea-42b0-b19f-4c4882587705.rup Calc=MJ8 Front Door faces: N N First Floor First Floor Second Floor Second Floor Job#: 539096 Aiello Home Services Scale: 1 107 Performed by Jesse Conway for: Page 1 Vijay Desai 600 Old County Circle RightSuite®Universal 2017 20 Pintail Circle Windsor Locks,CT 06096 17.0.28 Right A Mobile South Windsor,CT 06074 Phone:860-218-5130 Fax:860-292-2690 2017-Sep-22 11:14:52 Phone:860-869-1589 www.helloaiello.com jessec(ggoaiello.com ..:94ea-42b0-b19f-4o4882587705.rup • Proposal prepared by: wrightsoft' Aiello Home Services ' wrightsoft • 600 Old County Circle,Windsor Locks,CT 06096 • Phone:860-218-5130 Email:jessec@goaiello.com BIIL TO: Contractor license#:131-203350,S1-303032, E1-185643, SM1-5345, HIC-628926, HOD-635, F1-10603 Vijay Desai 20 Pintail Circle South Windsor,CT 06074 9/22/2017 Thank you for contacting us to provide solutions for your indoor home comfort needs.Our dedication to exceeding the expectations of our customers is second to none,and we look forward to the opportunity to demonstrate this to you. Based on the comfort assessment, home survey,load and energy analysis,and inspection of your existing equipment that we have performed,here is the HVAC system recommendation(s)for you to consider. Each of these options includes installation and standard manufacturer warranties. Circle your choice High Efficiency Better Efficiency Good Efficiency Outdoor Model Outdoor Efficiency Indoor Model Indoor Efficiency Coil Model AHRI Reference# Annual Utility Savings Federal Rebate Local Rebate Cost to repair/maintain Installation quote Net Investment(less rebates) Payback Period(years) Return on Investment(ROI) Please feel free to contact us with any questions regarding this proposal.We look forward to hearing from you soon.In order to be added to our installation schedule please indicate your choice of systems with your initials in the last row above and sign the proposal below. Thank you,Aiello Home Services Homeowner Authorized Signature Date P � ~ � \ � P N 1 LoS 5 107'-27 „b I ut -04- 19" Z4.21'� CJ�Q<011 l07 00 ' s} Los. - 04'- N 5 27 �4 -(, �` 28 Z 2 3/ 3 M>?S oo N Q< iQ �i ,0,e' - S 9 4c�ri 2 a 3593' P�'v r47 i�/ LD LY /� Z i" RS ; `� �' o �� /� .r • ^��47 s�� � N MAP IZ�F�iPI'iNG� Z 2l0 �z �a � / � cP. " LAK-bWDOD bNVbLDPb`�:> AND P�l11LDINL� S „ , 'p P Q PbZMIT APPL-)LA-TIDN PLAN " GAL b 1" =40' ��! PACE) �570� 1 ti0 a�J �y�� C / • Ii <. � 4� �JNC�IN�F�I2IN[� ING • IN ac'To� Z P s I r > / Z CP � �,, 4' ,z, � 6 G v a liJ�� O I I I l05 I g' p bU I L_D I N CB Z 5 T 1-I I-LA 3 3 S 1-40 W KI A� ETA V-b r-? t o / S! 8 10 .01 3Z5 J p i 5 gbs.9p, 34 -->Z"u/ 9 0` a, _ /PKo P�uip,��� � EL 32 g Q. Z 25 a PM , / U'' MY`,T-,C- 1 ti kiNNO,�' / Rao o QO R W 11 bL1 \ GaR e QTF'�Fp�p w. �Lpl�l� m EL 93q� W i tiopp0 'a g2g Off, 0 01 49 q o• / w S - •e N Ns7o � IZ=4�s.00`1 o IleSI '- or = SOO pO'/ L-4ZIo 31• T=2Z"1.0�` 1 g4- \ 4ti p AV LbC �N D ----9o--- -EiXI�TINC� LONTDUQ� �� P IZOPO��D LONTC�LI(Z5 — `—�''=—SAN ITA2Y ��W�2 LATPiRALS I INC' T1; bb �' FUSS&O'NEILL A��OF�C0N�F•���' Z AE2E,P5Y C-E>IZT 1 FY T HAT TN I5 MAP 1� ,.••'�;�'��`` R �f'ss� ' consulting engineers SIS>�STANTIALLV CO�ZR�GT r;GLASSA-Z ��a '° � MANCHESTER , CONNECTICUT ,AC.C_U iZALY) AND TART NO ZDN I N C. v �/ rn �� Z No. 12327 ,�� L A,t,VW VV D Re,(OULA,TIOI`15 Alb VIOLA-rbP k!JTA < N =<%cEs� 12C��P�GT TO TNT NOU�('i L.UCATIOI.1 =tio suRv"AO P�UI Lt71 N(� PEIZMIT APPLICATION Pt_AI`l C�Af2ACoE% F1002 �L C��/ATION� 5 �FJWC�R LATF�2AL5 ��! : REVISIONS U.�,l IT5 Z5 -33 ?AGE LAW 1z bN(-b i• JQ. L.`o. IZ3Z7 b L L I NL-JTO 1-I 20Ac0 UT I-1 .W I N D-`50 z LT. ENGINEERING 1750 ELLINGTON ROAD PROD. NO. DATE SCALE FIELD BK. DESIGNER I CHECKER SHEET NO. INC. SOUTH WINDSOR CT 06074 83-s8L I" =40' 4z 12.Co. I of I 203 644-4691 P P 8 j P,2pp � � \ i �jUILD1Nlo 'JO 'jl SHOWr-1 Ab LOLATE.D Lr 7- 8Lo 1 UL11L.DIN-L 2�- Z-I DWQ A5 LOc AT�p Lo Z13 -8Lo ` ,E5U I L,121Q Z93J b , -7- vlo 2DUILDI1\-IL9 28 �HOWt J AID LOGAT�D b-IGi aLo Z4.Z1'� p bu)L'PIK3L� 33 �H0\A/Q A� LOC ATED a 1 70. N 0 % w 27 N ^7 O,�O,, S Col. 20' vJ 22 3 N L V `� �^ ✓' a� ���� � rn MAP RI%FE'iiz �NG� St �. apo,��l �" ear / � r N � , � n � �-G' " LAkC'iW00t7 P�UII.DINC� FJNVEiL,OPFJ� AND P>1� ILDIN(� p' r < VbZMIT APPL.ILA•TION PL-AIQ I-r-,GAL Q��b 1" -40' !43 PGh� llv ,1 'Toy Z N Cp 3 I C 4 - 9 S / I. 3 N ro �4-L'ti� 6 `� A 6�• f l / �� v M t' 12 1 J N V N!✓ / %Y9 V< / / H / L LA LW D ly) 13, Lo 4fl.� N Ng io Q In N Z . WAT�RFORp / ' 0 7ZSZ 7 24' Q i D I 4z-L,;)60, -ram \. az /\V LbC--E✓N D �� P2DPO��D LONTOLJ�5 h�L —GJAN ITA2Y bWbIZ L4TbIZ4,L1�7> 'Y�X I�T► N C� T 2�t✓`� °••�,CON" - f' FUSS&O'NEILL I HE�2E.45Y LE,2T I FY T N AT TN I cD MAP I� ,c'�;�' ��`` R, cf�ss<��c; consulting engineers SLl INSTANT IALI_�/ L0221JC.T (LL.AS`-� A- 7- `�a 19�'`� MANCHESTER , CONNECTICUT 4LLLIIZALYj AND T-14AT NO ZC�N III� ` • ��[�UL.AT101�15 A�� VIDLATC'iD 1alLTH k,< IVENSEp�?'1 •' W }ZC'i`=�P�C,T TO TNT 1-IOL1�Pi t, OLATI0I.1 _qti�--. Q;o`'� •., suRv /�,� - Paul uT �A2ACE: FL.002 F.�L,FiVA-�'IONS s ��W�►Z LAT�`ZALS �Y . REVISIONS �1� ITrJ Z5 -33 ' I - 14-e�,Lc ?AGE LAW 2bNC b 2 3Q L_.5. IZ3Z7 rz I Lo-ate ALL I NC�,To N ROAD BOUT U W I N DSo 2, L-F ENGINEERING 1750 ELLINGTON ROAD - IZ' 81 PROD. NO. DATE SCALE FIELD BK. DESIGNER CHECKER SHEET NO. INC. SOUTH WINDSOR CT 06074 83-58C, Lo-Lo-81< 1" =40' 4zs I< L.2.C5 1 of I 203 644-4691 CERTIFICATE OF OCCUPANCY CHECK LIST Applicant - _ - Certificate of Occupancy Address Bldg. Permit No. Z2 Lot No. 3 3 i Date Submitted 8? Project Reviewed By Date As required in the Zoning Regulations, no certificate-of-occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall inlcude: Approved Denied N/A 1 . Approved building permit plan. 2 . Finish grading per approved building permit plan. U/ 3 . Site work; i .e. trees , shrubs, dumpsters , required parking 4 . Utility location G� a. sanitary sewer b. foundation drain �'. C . electrical & telephone d. water e . other - S . Appropriate certification 6 . Bonding Sewer Permit No. Pavement Excay . No. COMMENTS: -7���Z�J / .S' awe-�G='7��✓Co rivr2p.✓� w'//7t Tl�� /�v/�/.�G� £3 Lr TGVL�� 0�3` z �Gi���GsrL w�S