HomeMy WebLinkAbout18 BERRY PATCH BUILDING 2 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR I ��
BUILDING DEPARTMENT
1540 SULLIVAN AVENUE Bldg.Permit#
a�_ 644-2511 ext. 230 a
B ing Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job.
FTenant
Berry Patch 2H
$0-$1,000=$15.00 Street Lot No.
Over$1,000=
$15.00 per$1,000 18
or any fraction thereof gnation Apt.No.
APPLICANT Fahrenheit Mechanical Services Inc•
APPLICANT ADDRESS 56 Depot Street
Broad Brook, Cr 06016
APPLICANT PHONE# (860) 623-1991
OWNER Berry Patch Associates Limited Partnership
W N 8 Fq< OWNER ADDRESS 6 Executive Drive, Suite 100
Farmington, Cr 06032
OWNER PHONE (860) 674-5641
ESTIMATED COST$
IS THIS A CONTRACT COST? %Yes _No
jar' �G FEE ENCLOSED$
TYPE OF JOB.
`SOR-C X New Installation
_Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
HEATING ❑RESIDENTIAL
A/C ❑COMMERCIAL.
VENTILATION ❑ INDUSTRIAL
HEATING
❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC 91 WARM AIR ❑UNIT RADIANT HEATER PER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION PLANS
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF &
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY SPECS
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
Magic Pak M/N 51 HNC 2431-2B
GROSS HEATING CAPACITY(INPUT—BTUH)51,000 NET RATING(OUTPUT—BTUH) 41,000
TYPE OF FUEL
❑OIL—GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY
92 GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING PER
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE -F PLANS
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) &
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL-NO.) SECS
TONNAGE 2 COOLING CAPACITY(BTUH)24,000
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) 800 FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
303755 S-1 CP
CONTRACTORS LICENSE NO. TYP STATE
oc r 1 5 �,,
SIGNATURE OF APPLICANT DATE
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: ( 3 73
BUILDING DEPARTMENT
�D 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230 a y
Date B lding Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
FTenant
Berry paw 2H
$0-$1,000=$15.00 Street Lot No.
Over$1,000= 18
$15.00 per$1,000
or any fraction thereof gnation Apt.No.
APPLICANT Fahrenheit Mechanicall. Services Inc.
APPLICANT ADDRESS 56 Depot Street
Broad Brook, Cr 06016
APPLICANT PHONE# (860) 623-1991
OWNER Berry Patch Associates Limited Partnership
O W N S Fq< OWNER ADDRESS 6 Emotive Drive, Suite 100
' >> Farmington, Cr 06032
O�` } OWNER PHONE (860) 674-5641
ESTIMATED COST$
IS THIS A CONTRACT COST? X Yes No
f �sv FEE ENCLOSED$
TYPE OF JOB:
SOR C0 X New Installation
—Alteration/Addition/Repair
Revised 410IH2002
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑ YES ❑NO
❑RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
❑STORAGE
❑GARAGE ADDRESS
❑MD{ED USE
CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION New SIZE OF MAIN DRAIN 4"
NO.OF TOILETS 1 STYLE Elongated NO.URINALS N/A STYLE N/A
NO.OF BATHTUBS NO.OF SHOWERS 1 NO.OF LAVATORIES 1
NO.OF CONDUCTORS SIZE NO.OF STACKS 1 SIZE 3
AREA OF ROOF Bark NO.OF CATCH BASINS N/A NO.OF FLOOR DRAINS 1
Kitchen
NO.OF OTHER FIXTURES Sink KIND Single Bowl Stainless Steel
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES 91 NO
SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR
SIZE OF DUCTS SEWER OR SEPTIC TANK Sewer
SIZE OF WATER MAIN 2" SIZE OF WATER PIPING&RISER 3/4
Weil Mclain
WATER HEATER: TYPE Indirect MANUFACTURER P/US 120
DESCRIPTION OF WORK
THE UNDERSIUNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
P-1 00204480 P-1 Cr
CONTRACTORS LICENSE NO. STATE
SIGNATURE OF APPLICANT ° DATE OCT j 6 202
DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT
Application is hereby: TOWN OF SOUTH WINDSOR PERMIT#
BUILDING DEPARTMENT _j D0 0
ROVED 1540 SULLIVAN AVENUE Bldg.Permit#
^, 644-2511 ext. 230 a q
Date Buil Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
FTe7n-antD
Berry Patch 2H
$0-$1,000=$15.00 Street Lot No.
Over$1,000=
$15.00 per$1,000 18
or any fraction thereof gnation Apt.No.
APPLICANT TES L. Jacquel c/o Allstate Fire Sprinkler, Inc.
APPLICANT ADDRESS P.O. Box 2350
Hartford, Cr 06146
APPLICANT PHONE# (860) 246-7711
OWN S � OWNER Berry Patch Associates Limited Partnership
< OWNER ADDRESS 6 Miecutive Drive, Suite 100
' r Farmington, Cr 06032
CO) M. vk OWNER PHONE (860) .674-5641
ESTIMATED COST$
.� IS THIS A CONTRACT COST? X Yes _No
CJ FEE ENCLOSED$
TYPE OF JOB:
�SO R Co X New Installation
_Alteration/Addition/Repair
APPLICATION FOR SPRINKLER PERNM (continued from reverse side)
TYPE OF BUILDING TYPE OF CONSTRUCTION 5B USE GROUP NO. OF STORIES
M RESIDENTIAL
❑BUSINESS IS THIS APPLICATION ASSOCIATED WITH A
❑ASSEMBLY BUILDING PERMIT APPLICATION? ❑YES ❑NO
❑MERCANTILE
❑EDUCATIONAL CURRENT USE AND OCCUPANCY
❑INSTITUTIONAL
❑FACTORY FUTURE USE AND OCCUPANCY
❑ STORAGE
❑GARAGE ENGINEER,S NAME David K. TbcWson PHONE(860) 246-7711
❑MIXED USE
(Other please specify) ADDRESS P.O. Boat 2350
CITY Hartford STATE Cr ZIP 06146
KIND OF INSTALLATION
SIZE OF MAIN DRAIN 1 1/4" WATER PRESSURE AT STREET(PSI)
ARE SPRINKLER HEADS ALTERED? Of YES ❑NO
IF YES,CHECK ALL THAT APPLY: ®ADDED ❑DELETED ❑ALTERED
IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE)
L3 PROFESSIONAL ENGINEER ❑INSURANCE COMPANY
WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI)
ARE PUMPS REQUIRED? ❑YES NO IF YES,CHECK ALL THAT APPLY:
❑FIRE ❑BOOSTER ❑OTHER
ARE STANDPIPES PROVIDED? ❑YES ®NO IS A SPRINKLER SYSTEM PROVIDED? W YES ❑NO
SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM
TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP NSA PSI
DESCRIPTION OF WORK
New fire sprinkler system in two bedroom unit
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK
F10590 Fire Sprinkler CT
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE t0/21 0
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
IT#
Application is hereby: TOWN OF SOUTH WINDSOR / �PERM #
BUILDING DEPARTMENT
A
1540 SULLIVAN AVENUE Bldg. Permit#
644-2511 ext. 230
zt �
ate Buildin nspector
Application must be printed or typed
FEE SCHEDULE 18 Location of Job: :No.
Berry Patch
$0-$1,000 $15.00 Street No. Street .
Over$1,000= '
$15.00 per$1,000
or any fraction thereof "Tenant Designation
APPLICANT J-Electric
APPLICANT ADDRESS 8 SanricD Drive
Manchester, Cr 06040
APPLICANT PHONE# (860) 645-9891
O W 3 F OWNER Berry Patch Associates Limited Partnership
v .
q� OWNER ADDRESS 6 EXecutive Drive, Suite 100
:x
Farmington, Cr 06032
OE" OWNER PHONE (860) 674-5641
C ESTIMATED COST$ 2,945.00
' b
t� IS THIS A CONTRACT COST? X Yes _No
FEE ENCLOSED$
TYPE OF JOB:
S OR CO X New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
BUILDING PERMIT APPLICATION? ❑YES ❑NO
91 RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY Residence
❑:EDUCATIONAL
❑INSTITUTIONAL❑ �
EA3/ �FACTORY ENGINEERS NAME Engineering PHONE ' (860) 257-3968
❑ STORAGE 203 Briarwood Court
❑GARAGE ADDRESS
❑NUXED USE
CITY Ror-kY Hill STATE CT ZIP 06067
(Other please specify)
TYPE OF INSTALLATION/WHUNG METHOD NMC
SIZE OF SERVICE 100 amp SIZE OF MAIN CONDUCTORS #2 Al
NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? ❑YES ❑NO
NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 8
NUMBER OF SWITCHES 12 NUMBER OF OUTLETS 23
NUMBER OF LIGHT FIXTURES 9 NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS 1
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
Interior wiring of apartment to include outlets, switches and their cover
plates. Wiring of appliances and HVAC unit. Install light fixtures.
Imstall 100 amp breaker panel.
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK
123580 E-1 CT
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
Efectric # 1 S!79 APPLICATION FOR BUILDING PERMIT
Plumbing# I 13713 HVAC # 18 Winterberry Lane (Building 2) Dater' -
"
1�45� �. �
Sprinkler# (200 29999
FINAL APPROVALS Estimated Cost $38,000.00
Building Permit Fee $
Engineering COMPLETE RED BOXED AREAS Occupancy Fee $
g g' Insp.
Affidavit TYPE OR PRINT ONLY En I Fee $
�
Appr. for co. SIGN ON REVERSE SIDE / Total Fee $
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $
The undersigned hereby applies to do work according to the following:
Applicant The Metro Construction Corp_ Location of Work rR patAinterberry Lane Lot No. 2H
Applicant's Address 6 Executive Drive Tel.# 860-674-5640
Town Farmington, CT Zip 06032 Lic.# M00.900434
Owner Berry Patch Associates L.P. Architect Associated Architects
Owner's Address 6 Executive Drive Architect's Address 16 Spring Lane
Farmington, CT Zip 06032 Farmington, CT Zip 06032
Sq. Ft. New Area: 1 st FI. 896 s.f. 2nd FI. --- 3rd FI. --- Total New Area 896 s.f.
Purpose of this pennit New construction - multiple single family affordable dwelling
City Water[k Well❑ Septic System❑ SewerEIA
Ins: HO Area Basement Garage
Approved by Date Use Group Construction Type
Revised 6102
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the i own of
South Windsor and to notify the Building Ins for of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this buildi is be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is bcat n Fbuilding use is allowed.
Signe I hereby apply for a Certificate of pancscribed in this application for the permit.
Signed DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
**-29999-B 22,000
B01 FOOTING 10/02/03 WNB A
B02 FOUNDATION 10/10/03 WNB A
P03 ROUGH 04/28/04 PJP A
PO4 GAS TEST 03/30/04 JFF A
B04 INSULATION 05/11/04 JFF A CALLED ED ON CEILING TO BLOW IN REMAINDER OF
INSULATION
B10 FINAL 11/10/04 PJP A
B10 FINAL 11/19/04 PJP A CLOSEOUT
**-1270-5 1,000
**-11885-H 6,000
**-11373-P 5,000
**-18579-E 2,945
I