Loading...
HomeMy WebLinkAbout175 OAKLAND RD 5 Electric # APPLICATION FOR BUILDING PERMIT elumbing# p HVAC# 115 o&yoaru Rt a 61.1 5 Date: JO Sprinkler# p Estimated Cost $ 000-0 0 FINAL APPROVALS Permit Fee $ Building COMPLETE RED BOXED AREAS Occupancy Fee $ 30 Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $ Affidavit ► SIGN ON REVERSE SIDE t Appr.forCO. Total Fee $ TO THE BU DING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ r �1 The undersigned hereby applies to do work according to the following: 'K13 0 1 Applican7beMetro t=rvS-hrLxx4AQn L`oro LocationofWork 1"15 b0k,%0,^a —4z-0.c1 Lot No.13W16;�S5 Applicant's Address ►oD Tel # 2S�o- Ln 6477 Town FGrr,r.; �vn , CSC _ Zip 060S2 Lic.# h.AC_O. 0g0nq?,4 OwnerRe-r_r _A}�_ Architect ASoI Sjc> ed Arc-b it�C+s Owner's Address,F�,�c�w-1;.,� r� ��(?Architect's Address 3`1 M0yoni,A,),-s+ Zip_b6c�,3Z l -anv���Q, Zip o6c-,62 Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area 2-0-1 2-910 S� Purpose of this permit City Water Well J Septic System J Sewer 1"10 I H 1 Ins: HO SP Cert. Area Basement Garage Approved by Date 1,2-1 —lF- Use GroupC�L Construction Type - Revised 1108 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which his building and its use is allowed. ` Signed V Cl/-✓ — — — po"41 u� I hereby apply for a Certificate of Occupancy fort orkk,described diin this applic ion for the permit. Signed V-�t" s- _Vl.t/ C ✓cJ cc� 1"`l�r►rXjC�V DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS V&U&ot e s 1540 SULLIVAN AVENUE•SOUTH WINDSOR; CT 06074 Sop,co� TELEPHONE(860)644-2511 AN ACT CONCERNING CONCRETE FOUNDATIONS: Section 1(Public Act No.16r45)(NEW}(Effec«ive October 1,2016)Prior to tho issuance of a Certificate of Occupancy for a new residential or commercial building for which a concrete foundation was installed.on or after October 1,2016,the applicant shall provide the Building Official with written dMmentation of the name of the individual or entity that supplied the concrete and the name of the individual or entity that installed the concrete- Copies of such domnentation shall,be mattmed in the records of the office of the Building Official for not less than fft(50)years. Please fill the information in and submit to the Building Department: Date of information received/Med: IC;)-/ Project location: J -7.S O c A l u h U u cJ G tit t Job description: 7 c6- Ap V4r w P CONCRETES CONCRETE INSTALLER Name: C �,T Name: (Please Print) (Please Print) Address: WeSr 1MQ I�/ Cl) Address: '3 70 0-eM r o 1 �L r Phone/Contact: u v't' 7 J o C G toe 5 Phone Contact:,LU V M 1u d u a J �' q-60 �;-v& rs�.Z 351Z APPLICANT/CONTRACTOR Information: Name: M C$L"0 Cd+'i 5�wCr ,()-i (Please Print) � r Address: L Xf (-��``'���,Vy e Phone/Contact: / t r—O virn t�o too ro ki✓► C'G U Z E-mail: 1(0 Signature: Date: "I RECEIVff. J DEC 13 NIO South Windsor Buildin De artment INSPECTION FIELD SHEET O1/18/19 Printed by Acevedo, Maria 10 31 34 INSPECTION: 99131 FOOTING PERMIT: STATUS APPLICATION: 201701419 LOC: 175 OAKLAND ROAD SOUTH WINDSOR PROPERTY ID: 65700175 OWNER: BERRY PATCH III LLC CONTRACTOR: REQUEST BY: PROJ DESC: BUILDING PERMIT FOR APARTMENTS BUILDING 5 WORK ORDER: INSPECTOR: ROSE RESULT: PASS REQUESTED: 10/23/17 PRIORITY: SCHEDULED: 10/24/17 PM COMPLETED: 10/24/17 UNPAID FEES: 00 Date Time MILEAGE: 00 TIME: TRAVEL ONSITE COMMENTS BUILDING 5 ALL INSPECTIONS: INSPECTED INSPECTOR RESULT INSP DESCRIPTION 10/25/17 DOUG PASS B001 FOOTING 10/27/17 DOUG PASS B001 FOOTING 11/27/17 DOUG PASS P002 PLUMBING UNDERGROUND 04/10/18 ROSE PASS E003 ELECTRIC ROUGH UNITS 1 &2 05/23/18 DOUG PASS P003 PLUMBING ROUGH 05/23/18 DOUG PASS B003 FRAMING (ROUGH) 05/23/18 DOUG PASS E003 ELECTRIC ROUGH 05/23/18 DOUG PASS H003 HVAC ROUGH 06/04/18 DOUG PASS B004 INSULATION 07/16/18 DOUG PASS P004 PLUMBING GAS TEST 12/17/18 MAUL PASS F005 FM PENETRATIONS/SEPERATION APPROVED - CODE COMPLIANT 12/17/18 MAUL PASS F025 FM EMERGENCY/EXIT LIGHTING APPROVED - CODE COMPLIANT 12/17/18 MAUL PASS F035 FM EXITS APPROVED - CODE COMPLIANT 12/17/18 MAUL PASS F040 CO -FIRE MARSHAL INSPECTION hPPROVED CODE COMPLIANT 12/26/18 DOUG PASS BO10 FINAL APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT AppRp 1540 SULLIVAN AVENUE Bldg.Permit# �-�,I ,I� 644-2511 ext. 230 Date Building InWe or Application must be printed or typed FEE SCHEDULE Location of Job: $041,000=$15.00 �lG<s/�i>!c: �lL� &&,iQ�4 J� Over$1,000= Street No. Street t No. $15.00 per$1,000 _�j or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS '—1 APPLICANT'S PHONE# 6 9 OWNER OW N S�►q< OWNER ADDRESS 6 Ex e.e u fir✓P d— -7YZ,, OWNER PHONE 0 a ESTIMATED COST$ -7) 70 , C6 7 IS THIS A CONTRACT COST? Yes _1GNo FEE ENCLOSED$ 1 �q '• ° ` TYPE OF JOB: �SOR•CO -"New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR HVAC PERMIT(Continued from ieverse side) TYPE OF STEM: TYPE OF BUILDING: WOEATING RESIDENTIAL A/C ❑ COM EERCLkL ❑ VENTILATION ❑ INDUSTRIAL- HEATING ❑ STEAM LOW PREES LIMIT LBS. HIGH PRESSURE LIIVIIT LBS. 34IYDRONIC ARM AIR ❑ UNIT RADIANT.HEATER EXISTING RADIATION ADDITIONAL RADIATION 'JOTAL RADIATION DESIGN TEMP.OUTSIDE --7 OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTL" °F(HEAT LOSS SHE MUST ACCOMPANY APPLICATION) ^�- DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 1 p 1-54,4Z d i 'I- �°o zS 3 C le�- 'p, ( S vwo GROSS HEATING CAPACITY(INPUTBTUH)_ NET RATING(OUTPUT BTUH) ? TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION: ❑ .INSIDE ❑ OUTSIDE CAPACITY CAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE--S-7°F INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) A o is 3 2� A Q- C 2- 07 av `Z t TONNAGE c/y COOLING CAPACITY(BTU" VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) . FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. E STATE SIGNATURE OF APPLICANT V _ DATE 1 — DEPARTMENT DECISION APPLICATION FOR SPRINKLER PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT -� APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# � �, 644-2511 ext. 230 Date Building Inspect Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT erS-4414V hm C � APPLICANT RESS 110 A 4A (9GC'1 t7- Gri4rd, CT ©' APPLICANT PHONE# 90 r — l OW N SF � (� OWNER �'r �Ll�tG1� � LL�- � q� OWNER ADDRESS [� ISy1C[��LL; 7 LAC 2)17),,e j2ze sze /Lei (I.#) c ,r OWNER PHONE S(:�?D . 6 741, `j 04 OESTIMATED COST$ l y I , D �.� IS THIS A CONTRACT COST? _Yes e.No FEE ENCLOSED$ TYPE OF JOB: Sp R-C O -"New Installation Alteration/Addition/Repair -oN �� Revised 4/01//2002 ' ICI APPLICATION FOR SPRINKLER PERMIT (Continued from reverse side) TYPE OF BUILDING TYPE OF CONSTRUCTION USE GROUP 5E3_ NO.OF STORIES RESIDENTIAL BUSINESS IS THIS APPLICATION ASSOCIATED WITH A ❑ASSEMBLY BUILDING PERMIT APPLICATION? ;1 YES ❑NO ❑MERCANTILE ❑EDUCATIONAL CURRENT USE AND OCCUPANCY -/ QS D4Cel ❑INSTITUTIONAL ❑FACTORY FUTURE USE AND OCCUPANCY ,��-n- S ❑STORAGE LJ GARAGE ❑MIXED USE ENGINEER'S NAME EMnre FW PHONE A0•24C•771/ (Other please specify) ADDRESS l 1 U �uY��t Uj ��iC,cOC CITY bkLk4>G rek STATE e-T ZIP KIND OF INSTALLATION SIZE OF MAIN DRAIN — WATER PRESSURE AT STREET(PSI) ((ZS S4-'�-',� 15 t�FS,��1r ARE SPRINKLER HEADS ALTERED? ❑YES ❑NO / IF YES,CHECK ALL THAT APPLY: ❑ADDED ❑DELETED ❑ALTERED IF MORE THAN 3 HEADS ARE ADDED HYDRAULIC CALCULATIONS ARE PROVIDED BY(CHECK ONE) ❑PROFESSIONAL ENGINEER ❑INSURANCE COMPANY WATER FLOW WATER PRESSURE AT SPRINKLER HEADS(PSI) ARE PUMPS REQUIRED? ❑YES 00 IF YES,CHECK ALL THAT APPLY: ❑FIRE ❑BOOSTER ❑OTHER ARE STANDPIPES PROVIDED? ❑YES /aNO IS A SPRINKLER SYSTEM PROVIDED? AYES ❑NO SPRINKLER SYSTEM MAIN WATER SUPPLY RATING GPM Ne w T(Ls fo i TOTAL DYNAMIC HEAD(TDH)OF FIRE PUMP PSI DESCRIPTION OF WORK 1�S I14,0ti o� VFPA f3 Z Spr.nkler S�,� ► THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Fli,/l CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLIC DATE 0 -c 110 Murphy 11 Hartford,CT 06114 6 06114 encore W�BSITE: HOLDINGS www.EncoreHoldingsCo.com PHONE: 1.860.246.7711 } February 5, 2018 Town of South Windsor South Windsor, CT Attn: Building Official / Fire Marshal Re: Application for Permit Gentlemen: In accordance with Public Act 91-95, this letter authorizes the below named agent to sign the above referenced application for Jeremiah C. O'Connor (License # F0011511-F1). Fire Sprinkler Contractor- Encore Fire Protection 110 Murphy Road Hartford, CT 06114 Project Name: 175 Oakland Road Building 5 Location: 175 Oakland Road Authorized Agent: Tyler Satalino Thank you for your cooperation. Sinner w 4 ^ miah C. O'Connor FC '�T ELECTRIC FIRE SUPPRESSION �� encore ALLSTATE U.S. Fire Group 0" 1 rHSSG SYSTEMS GROUP encore I SUPPRESSION FIRE SYSTEMS DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR r76oG 5q BUILDING DEPARTMENT APPRQVEQ 1540 SULLIVAN AVENUE UL_: 644-2511 EX E 230 iaBldg."Pe t# (Date) (Building Inspec Application must be printed or typed FEE SCHEDULE Location of Job: I-7 $041,000=$l 5.00 Street No. Street Lot No. Over$1,000- _ $15.00 per$1,000 or any fraction thereof Tenant Designation Apt No. APPLICANT �( ka Ycc 60S P APPLICANT ADDRESS APPLICANT PHONE# A(ge) 7�V Ow) (-Y) OWN S F,q OWNER ✓ ��CL� C 7 ) OWNER ADDRESS EX�n r-1-1 fe f ro Sct i+ I0c OOWNER PHONE 'SZoC� - ESTIMATED COST $ f SO D U U IS THIS A CONTRACT COST? YES ✓'NO o o FEE ENCLOSED$ 14 y 40 TYPE OF JOB: SO •CD ✓New Installation Alteration/Addition Repair Revised 12/22/11 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A l�l RESIDENTIAL BUILDING PERMIT APPLICATION? )Z) YES ❑ NO O BUSINESS CURRENT USE AND OCCUPANCY cDGl)�f11,'ni O ASSEMBLY O MERCANTILE FUTURE USE AND OCCUPANCYj�}�S O EDUCATIONAL O FACTORY O STORAGE ENGINEER'S NAME PHONE O MIXED USE ADDRESS 79yez� (Other please specify) CITY STATE ZIP TYPE OF INSTALLATION C104k^!ja �-&N" f I SIZE OF MAIN DRAIN NO.OF TOILETS Z Y STYLE lI ZP, Tq,kkC NO.URINALS_ 0 STYLE NO. OF BATHTUBS NO.OF SHOWERS NO. OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS_�� SIZE AREA OF ROOF ISct,Ic— " NO.OF CATCH BASINS _ NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES Al KIND lL/7c��Gl 3 /ZCJAi,=4tV --5 ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW OYES ONO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER hk Id WATER HEATER: TYPE ICIA1455 MANUFACTURER r114, DESCRIPTION OF WORK i THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 7M&zZ l C CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE APPLICATION FOR:ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOC71M WINDSOR PEPIVUT# Application is hereby: BUILDING DEPARTMENT APP O . 1540 SULLIVAN AVENUE 1 ., 644-251 i ext. 230 Bldg:Permit# Date Building Insre� • . Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 i S Oczr\c,.rd �R� '���; 1 d Q IS Over$1,000= Street No. S Lot NO. $15.00 per$1,000 �n► s 5ot- 5�� or any fraction thereof Tenant Designation Apt:No. APPLICANT T3\c,e �:�� f- kr C. APPLICANT ADDRESS APPLICANT'S PHONE:# Z6c_�• kk3a• SSsbg OW N S OWNER �� �r.�-A OWNER ADDRESS C OWNER PHONE �� �,y C ESTIMATED COST$ O D, D 0 IS THIS A CONTRACT COST? Yes No FEE ENCLOSED.$ glQ y o TYPE OF JOB: *101 dSOR•CO , New Installation Alteration/Addition/Repair -70 Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE©F BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES ❑ NO RESIDENTIAL CURRENT USE AND OCCUPANCY A lq w ❑ BUSINESS 0. ASSEMBLY FUTURE USE AND OCCUPANCY A ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE.',job: 3.�•`-� $$ ❑ FACTORY ❑ STORAGE ADDRESS _ ?J2 Nl emu' 4�y e- r - ❑ GARAGE . ❑ MIICED USE CITY ✓� r,c�l s v STATE C i ZIP U k 6, (Other please specify) TYPE OF INSTALLATION I WIRING METHOD -Go"-f,S4 �Z c�� Q G•L . . SIZE OF SERVICE(oGa P-, SIZE OF MAIN CONDUCTORS 'k%FA NUMBERS OF METERS .t') NUMBERS.OF DISCONNECTS AND RATINGS NUMBERS OF PANELS �-1 NUMBERS OF DISCONNECTS REQUIRED? ❑ YES 0 NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES. NUMBER OF OUTLETS NUMBER Of LIGHT FIXTURES NUMBER OF HEAT CIRCUITS: 1. NUMBER`OF A/C CIRCUITS 16 SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMTITED. DESCRIPTION OF WORK �_�rc. (\e w r.;Pe.1�Fvw...J. \ov.�.e OQ� �\.�s cv��•\� ��r`.� �a i 1�c..\fie.�liice.,���r�a\er. t THE UNDERSIGNED HEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK 1Z3S�� �.- ► Lk, CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE �� �1 SITE COMPLIANCE CHECKLIST TOWN OF SOUTH WINDSOR,CONNECTICUT RTCEIVED ***** FOR C OF O***** �Bi�9, s.- DEC � � Zoos ADDRESS / 7.-:F 044-JA LOT/UNIT# Reviewed by i DEPT. CONTACT/DEV �� Date Reviewed 7!'1 proved/ enied PH# 7 Reviewed by _(Planning) uly Date Submitted / Date Reviewed is id pro /Denied Date Reviewed Approved/Denied(Health) As required in the Zoning and/or Subdivision Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved / building permit plan ✓ 3. Site work; i.e.trees,shrubs, / dumpsters, required parking 4. Utility location; —�G a. sanitary sewer/septic systems b. foundation drain -� C. electrical &telephone d. water e. othez c/ 5. Sewer connection charge paid 6. Appropriate certification Ik 7. Bonding 8. Planning&Zoning/ Inland Wetlands Considerations a. Lighting b. Signage Freestanding Wall C. Fee in lieu of Open Space COMMENTS: /2 t 4s -is t.� SL.� ��u, 1 N L, 6'/<y Ali ra J.n.a Y' ../M'\ J��.. ��.1 � �f' �. �✓.i...t� It.r►� ��n✓G 7� , I..'�c sl l{`i s/engineering/molloy/site compliance checklist S44 0727E a w r\ IL 52 226.14' ' S44 07'27'E � 194 Q X o c 481.04 _ - - - )AD � I v >- 0 I� h W W m o0 0o C Y pAK` 2110 AND J 'x m LPL V •�- '•fie cc F- 30 a o 4tP/Nf0 F a/ LL N N d t� _ �( ao y p N Wda'�� 6ry1 P5�PSQ��yO�l m Fq�� Q N w .1 a . N0 fAW M y Z ��Pti 1�eG AKLANDR10 AD �0 S�e\0 1 �J�o�6�� eP��+ �P� c 3 <w E�� tib �J�O� /�2 2 O d v 0 G�ly� 6 l5E <gNFHFDav N Iw _ CT �M UTE 30 5 �! C W J z {7 M jr;� wwv wvSTR SITEh O W N wv FFr O U.J SIGN \ ( Sl EVER 26412 W/RISER ) \ v o p o pUe M'C ^ O" ; MLL. Z N / E 4 BRppK m a - LA 29 - = test - - 12 ^ - - � ' / l ^/ / - - -CB/y6 1 - - - ^ - - - _ - - _ - 127- - - - - - \ \ �v`11 DMH#6 - - - -126-ti�� Rox TEL.L �ti -2 126 - - ' 50' F. Y. V \ - - RIP-RAPS a ' _ 9 BIT LOCATION PLAN ei �� \T _ -12 \+1�6 - - = _-� - \ _ _ -5 6' /f 1 \ \ 125 / T=1000, i xs ° ° I- 0' 24.0' J 4. ` I YI 2 2.0' S6.7' ❑I \ INLET 3 I k k Ems$ 2.0' ❑I \� \ pk / w v w�, wv \ rP' \ BIT. BINDER LEGEND2tg �y EXlS77NG FRAME BUILDING CA BOX j/ \ /\21 Da \ COURSE o BUILDING 1 /RP, \ AREA UNDER CONSTRUCAON { °f} F ° im ° `\ °, � \ � / � d O '� \ ! � D4 DESCRIPTION � �� I`� ROOF PEAK. m y ^ EXISTING a s = s w ❑ o y1 � _yN / 1r / \ \ a � -127 - 1 l" DOMESTIC WATER r. D INLET#23 \ o I ❑ ( \ 0 � / I Q \ - - - wx- - - wx- WATER MAIN Q ° 1 2.0' INLET p ) �° \ +11 10 ' - - BIT. WALK � T L.��)X oh - - - wsx - - w WATER SERVICE 2.0' l D \ BIT WALK - I ^ DQ - - - - - DMH#11 �0 1ry1 - Sx - ( M J 1 9 1 L - - - - 1 - I ��0 FIRE HYDRANT > \O p\ 56.5' Wiz, cv _ - - - - - \ -� - I NATURAL GAS o O Q �p B0H 0® I BOH 2A0' 1�1 k O 110 0� / /+�C H 7 \ Sv I O N ,27` / 19.9' 0 2� \ !u+\ - 1� �3 INLET ---.- r/ ---- -.-_'> \\ o l 35.0' 52 1 19 6� - - - LL cx- - - cx- GAS MAIN a V > V o W/ l�I1V)4/ Js.' c1 x 126.8 I I 1 1 - �' 3 -� N45 52'04"W POWER •,? FENCE 16 340. ti 34.0'^ 340' ZW ° ,, ox ELECTRICAL LINES, OVERHEAD � N N HDCP SIGN BIT. WALK e SIGN I - ❑ ° ° O r �� w `- E (TYP.) - - 20. I (- ° m m I W X h 0 O MAIL - - EUx - - - EUx ELECTRICAL LINES, UNDERGROUND Lu � +� BOXES w O c �- - - - - \ 1 \ ,1• (D� \ v o � w ti� / I - - CZ,L Iv �b e ° - �k m V I 00 17.3' i. � L- �: Cri 124" 12.4' 125' S.8' /'I� "F.��1 '5k / I V EXlS71NG o / \-/J f72' `� UTILITY POLE +• \ � L 1- 6. I \ BUILDING 6 w PROPERTY IL 0 1 k 125, 6. INLET 14 `ti6 1\ SMH I FF-127.7 cn R1 ` h PAD DUMPSTER 01 h� 1 6� I A/C UNITS(TYP.) N1 ai 1 + m J I ° - - 5, y 1,5• �ti z ,� I / ,� 1 PROPERTY LINE BIT. BINDER \ / �I EASEMENT LINE ° 00 m +, +\ B $° w ° o I INLET STRUCTURES ; m m \ COURSE / cn \ Q6' w c0 \ ; m o C EXISTING q I / 0 IRON PIPE o- /- DMH ❑ EXISTING N BUILDING 5 '� cj - S / 6o FF.'1275 v. 26 / 7EZ INLET ?. 1 a M o o I o J � BUILDING 5 J 2 1 �'+ �o o O,B#7 \ 12(j' +,1, FF.'127..5 V - , 91 b #1.5 40.2' o STRUCTURE TF INV INV INV O IRON ROD INLET#25 DMH#4 1 / BIT. WALK 6 CB 8 h \ -� w N 1 �s \ �c I 14 \� I a V'� INLET#3 127.81 124.42 (8"E) 125.25 (4"W) El MONUMENT k1 $O h Q CONC. f2 s' 5.8' + E 0 3 L PAD 726' CONC. {, l V CN D 125' 125' PAD lT. WALK �j 20.0' 20.0' �p CHI INLET#4 127.86 125.54 (4"W) 124.44 (8"E) ROADS 0 BIT WALK OCS1 W/ VINYL py/ KNyL 11 FENCE v CB#9 CATV OX �p W O 0 [7 FENCE v Na m Cn INLET#5 127.25 124.97 (4"W) 125.03 (4"E) 123.84 (8"N) QR -ty-0- p k'2s - _v26 ,ti0 as ° sa' (TYP) � o o (nP) I I n -°- SIGN x + 9 CA TV BOX 200' # 124.43 121.04 (8"N) 121.81 (4"S) 34.0' �, � INLET 6 ° 06P`IGN \1�h 34.0' 34.0' \ 34.0' I ❑ 1>1 20.0' N INLET#26 N SITE FEATURES j � + INLET#7 125.35 121.94 (8"N) 122.88 (4"S) U Z 10' S Y ET �B ° 20.0' c6 4 +\ I - 1. I. - -----•-1 ocs 3 f y6 EDGE OF WATER H \ `- \��`-L- -� - - - - 126� +1 ` c„ 40.2' a INLET#8 124.84 121.44 (8"N) 122.59 (4"S) . . . . . . . . . . r >L ° I 350' a _ - - ti6 ti / -h - DMH f - - 124.28 121.s2 (4"w) 1zo.8a (s"E) STONE WALL < w INLET ( �ti 1 --1Z5 ,a- - - - + h k 125- - ► # w DOWNSPOUT IYP.) DB �6 k a B/T. WALK I EXlST1NG INLET#10 OR TREE O z INLET 7 I CONC. a \ J Ln o PAD ° \ \ k /+��- 125 -- -- - - J 9- � BUILDING 6 . . . . . . . n W VINYL ' 9 + 1 �" --125'� I I BUILDING 19.9, # TREE LINE Z / EXlS71NG OCS6 / �y \ t9.5>' INLET 11 V y a FENCE BUILDING 2 ® I \ - 0 1 ROOF PEAK: SANITARY SEWER Q _ (-YP) FF.•125.E BIT WALK - - K� f/ T#16 1 2.0' N I \ N � INLET#12 � Z � ° C I ROOF PEAK.156.97 17.3' I 8/T W LK i - +�/ / 1 ` 1 \ in - - Q � � 17.3' r k6 / / INLET 22 / \ 425' 9 1 r, 5 ' INLET#13 125.42 Sx- - - Sx- SANITARY SEWER MAIN J r / I 1'k i 124 .-. 14.0' 14.0' \ "5' k6 Qre 1 17.3' O c/1 \ INLET 9 \ iN 1 \ 1 B°H INLET '1� 0 +�ti �l� I I f7.T ' INLET#14 125.49 N/A OO SANITARY SEWER MANHOLE Q Q Q �� h 425' 14.0' N ,�• ` :..- l1 b I INLET#1s STORM SEWER a Z Z 3 u 19.8' I 1 _- - -124 m I / 14.0' 2.0' INLET�18 0 " 124.4 CB f0 A o INLET#16 124.10 120.69 (8"N) 121.84 (4"S) STORM DRAIN PIPE iLn� z 2.0' A/C UNITS(TYP.) I o 1 I 19.8' �" •. EXISTING L,�' I I, INLET#77 _ �1 1 w w" �� O / / u 1.0' ° (,A/v rfVT BUILDING 4 N +14' ti6 1 11 0 0 40.0' ° f \{�° # I h5 INLET#18 124.06 722.63 (4"W) 121.38 (6"E) D >" 350' V STORM DRAIN MANHOLE N FF.•124.5 ` k' SMH 4 v �' 1 11 ❑ 4'1 EXIS77NG 2 0' A/C UN17S (TYP.) kr�0 +� Z 19.9' I 19'9 \ �i ® CURB INLET 1 v 0. r wv +� BUILDING 3 `�s �� -'� \ \ �"" INLET#19 123.45 122.14 (4"W) 120.81 (6"S) (n W II �- h' k � v CA so +`\ \� wm I N FF.124.5 N 1.0' aJ + ti I D \ -- \ ) ) / WETLANDS v �'�� 20.0' hk ROOFPEAK.'157 m ❑ l \ INLET 20 m \II\\ 20.0' 1�\ _ I A/C UNITS(TYR) B& 2.o' \ -- - - - - - - -'-' - / i i \ D4 CATV BOX 6 u INLET,#19 \ `\ INLET24 t 1 '123' - J CONC. o' \ BIT. WALK P ❑ 1. f4.0' 20' 14.0' /WH#1 -_ / � / INLET#21 124.80 121.39 (8"N) 122.41 (4"S) WETLANDS LINE O 11\ v AD \ / / INLET 22 124.87 .. j 1\ 20.o' f W/ VINYL H 42.5' F \ o 0 0 o i�� / # 121.44 (8"N) 122.21 (4"S) \\ 20.0' BlT. WALK a +ilk) ° ��'� FENCE , �I / i- - - _/ \ INLET#23 125.76 122.59 (6"S) wv cv �� (7YP) 20' 4.0' e 0 ( \ / o _ _ _ _ _ \ i NOTES.' ( + t4.o' 20' 425 3 I '2sr INLET#24 123.65 117.82 (24"E) 1. PROPERTY IS IN THE AA-30 ZONE. m 40.0' CONC. 1 CB ~ + r ' _ / 2. TOTAL AREA OF COMBINED PROPERTIES = 427,025 S F., 9.803 ACRES. ° PAD \ 1 L_.-. ` - -BOJ ---I m a OCS¢4 I \ / o / / / \ - VINYLQ / //(�^ �/ /6 INLET#25 J. HORIZONTAL DATUM IS BASED ON NAD83. VERTICAL DATUM IS BASED ON ° W FENCE � I D; tV - 1 �� 123.E x CONC. DUMPS7ER PAD o // // LC /\ 1 ' 6 1ti I INLLIT // t� / INLET#26 126.06 121.37 (24"W) NA V088. M (TYP) I I _ l �+ 1�' ,� 1ti + °� I 20 / °�// // ,� i I / 4. WETLANDS WERE FIELD DELINEATED BY PIETRAS ENVIRONMENTAL GROUP ON I 19.8' BUIEXILDING ,s.e' I �� �Iq + 4t�s' �E�123 j � ' /j j// ` ,tom / / / AUGUST 2016 AND FIELD LOCATED BY DESIGN PROFESSIONALS, INC.4 ` BUILDING 2 �I ti J�7 \ ° \ o �MH 3 ° // / / �g �J / / / AUGUST 2016. `'1 0 N FF.'125.5 N / m OV �� . A(QU#1 T O ) / L n w # / / / L� O 1 ROOF PEAK.756.92� 123.$x (�❑ / fya °�/ / / �I/ / / - / 5. PORTIONS OF THE PROPERTY FALL WITHIN THE LIMITS OF FLOOD HAZARD ocs - %' /// / 6�•3���� / r j ZONE '�4E" AS DEPICTED ON: 'FIRM FLOOD INSURANCE RATE MAP TOWN OF ` 173' 173' I i \ �- _ kti - ° f/�/ N / / SOUTH WINDSOR CONNECTICUT HARTFORD COUNTY PANEL 383 OF 675 1�0 / - / \ �tiry' / �/ - / „ COMMUNI TY PANEL NUMBER 09003C0383F EFFECTI VE DA TE- SEP TEMBER 26, o #1 - / \ + - - - i // 2008 FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE z v 1�\ \ ADM/NIS IRA TION 6. UNDERGROUND UTILITY, STRUCTURE AND FACILITY LOCATIONS DEPICTED O \� o I I I I I I \ , + / ��® ` / bo +`4 \ \ _ / - - J AND NOTED HEREON HA VE BEEN COMPILED, IN PART, FROM RECORD J \ \\ I I ry� ,��• , O'CS#7 � \ o o /R1P-RAP MAPPING SUPPLIED BY THE RESPECTIVE UTILITY COMPANIES OR BIT. WALK - , �1 / BIT. BINDER1 / GOVERNMENTAL AGENCIES, FROM PAROL TESTIMONY AND FROM OTHER l / +11 / COURSE // J OMH#10A / C \ o Q SOURCES THESE LOCH TIONS MUST BE CONSIDERED AS APPROXIMA TE IN Lu ocs2Q -- - - NA TURF. ADDITIONALL Y, OTHER SUCH FEA TURFS MA Y EXIST ON THE SITE, � \ \ \` \ `\. � 14' / D DMH�1 / H#2 � / / / _ J sP ' THE EXISTENCE OF WHICH ARE UNKNOWN TO DESIGN PROFESSIONALS, INC. / THE SIZE, LOCATION AND EXISTENCE OF ALL SUCH FEATURES MUST BE _ \\\\\\\ \ A`6f,.�• - 12� �- \ \ D .rw _ / 2 / / CIt-/n /)CTCDAA/A/Cn A A/n vct�/nu-n n 00 \�� \ .c -f' •- - - - 'Add`-=% i21.7X �e - - `'L:S' ( //��ci cv�/I-/,/v✓//vr-u -ilvu vr-r lr/Gu aI v 7r1E ,4PPROPR/ATE fIUTHOf(lTIES o \\\\\\\\� __ = 1eeNs-ouelPSraA � -J OMH \_ - - - �� TO CONSTRUCTION. �Dw - - - - ��O$86' �j� - - / 7. CONTRACTOR SHALL CONTACT "CALL BEFORE YOU DIG" FOR UNDERGROUND _ UTILITY MARKING AT LEAST TWO FULL WORKING DAYS PRIOR TO START OF - '\\�\\\ -__- - - - - - - ' - - - - UTILITY STRUCTURE TABLE DMH#10A 122,gg CONSTRUCTION. 1-800-922-4455 OR WWW.CBYD.COM. # 127.St 121.81 (30" E) 121.41 (30"S) v � \ �'�\\`- ��� ,` - - _1 � `� ` - - - - - - � - - - DMH 11 1; � \ \\ ���\\` .� -, -1 JOB � � � _ - - - - - - - � -- -� _. _ o \\�\�� _`_ __=_-� ` == __ \_ ____ - STRUCIURE TF INV INV INV INV DMH#11A 125.80 MAP REFERENCES. 0 - - - \\�� ` _-5�'' - - CB#1 121.78 118.0 (12" W) DMH#12 1. AL TA NSPS LAND TITLE TLE SURVEY BERRY PATCH Ill, LLC 175 OAKLAND ROAD t. \ =1 105_�� \` - 7� ' = _ CB#2 120.95 115.85(15" NE) 115.82(15"SE) DMH#13 / SOUTH WINDSOR, CONNECTICUT FORMERL Y KNOWN AS 151 & 195 OAKLAND ROAD Z Q - - .� - CB#3 124.25 117.32(15 NE) 119.07(15" E) 117.13(18" SW) DMH#14 127.37 DATED 8/25/17 REVISED TO 1/18/18 SCALE 1'=50' BY DESIGN PROFESSIONALS, CB#4 124.49 120.77(15" NW) DMH#15 122.28 INC. 0 J CB#5 125.40 119.95(36" S) 119.91(36" N) DMH NEW -8.6 N 8"PVC -8.5 S 8" PVC C13#6 124.95 120.27(36" N) 122.87(5" S) 123.05(4" S) 0CS#1 126.05 123.18 (36"N) W (N/A) S (N/A) SURVEY NOTES• Q d0 / CB#7 124.41 120.47(12" SE) ocs#2 123.11 117.28 (36" E) 117.60 (15"SE) 1. THIS SURVEY AND MAP HAS BEEN PREPARED PURSUANT TO THE ' rouo l7F•Cl l/ Tl/)A/C rIC /'`/)A/A/C!'T//1//T crA Tc n ncA/n/r- i,�vvc.n//v/v.� v/ L.vivlvLl.//Llu/ J/H/r- rl VC/vu1r-0 SECTIONS 20-JVL/D-1 l/7/YU /A 2 Z v '- �m� IL5.64 121.76('IL SE) 0CS#3 126.03 20-300b-20 AND THE 'STANDARDS FOR SURVEYS AND MAPS IN THE STATE N im W O V o m CB#g 125.65 120.22(12" NW) 119.44(12" SW) ocs#4 123.aso OF CONNECTICUT" AS ADOPTED BY THE CONNECTICUT ASSOCIATION OF LAND W W M ocs#5 123.02 SURVEYORS, INC. ON SEPTEMBER 26, 1996. W CB#10 123.930 19.79(12" N) 118.38(15" NE) 118.28(15" S) cc ' Q CB#11 124.11 N/A OCS#6 125.26 Q �o • TYPE OF SURVEY IS AN IMPROVEMENT LOCATION SURVEY-RECORD AND �• IS IN TO DEPICT THE LOCATION OF EXISTING CONDITION RELATIVE ocs#7 11s.s7o 116.26 (6"GONG) TO EXISTING PROPERTY LINES AND EXISTING & PROPOSED EASEMENT Lwr O ; CB#12 121.17 117.89(12" SE) ui �m5 DMH#1 122.96 114.90 (15" NE) 110.39 (18" W) 110.89 (15" SE) WOU#1 121.58 115.54 (125"W) 117.18 (15"E) 115.29 (15"S) LINES. i�i. ,••' O Q DMH#2 122.06 115.23 (15" N) 116.66 (12" E) 115.20 (15" SE) 115.22 (15" W) SMH #1 121.96 0 THIS IS A RESURVEY BASED ON MAPS REFERENCED HEREON. y QM I DMH#4 124.61 SMH #2 121.92 . HORIZONTAL ACCURACY MEETS CLASS A-2 STANDARDS VERTICAL V w �j SMH #3 123.02 DMH#5 127.7o ACCURACY MEETS CLASS V-2 STANDARDS �6ti/,�p� DMH#6 1z6,z1 SMH #4 124.46 TO MY KNOWLEDGE AND BELIEF, THIS MAP lS SUBSTANTIALLY CORRECT AS NOTED DMH#7 127.83 119.93 (42" W) 120.13 (8" PVC S) SMH #5 126.35 HEREON. SHEET DMH#8 126.07 117.57 (12"W) 117.57 (15"S) v DMH#9 " '� '�•> 12327 VIIIIIIIIIIIIIIIIII1 � DMH#10 125.54 LAWTENCE R. GEISSLER. ✓R., L.S. LIC. NO.. RECEIVED DEC 14 ZU16 SOUTH WINS,OR ENGINEERING DEPT