HomeMy WebLinkAbout17 CARMAN RD APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby: BUILDING DEPARTMENT
l5bD2Ss2
App O 1540 SULLIVAN AVENUE Bldg.Permit#
.u w 644-2511 ext. 230
Date Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 f 7 -" /Zaa.c/
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS 126 /Z s,c
APPLICANT'S PHONE# �G^�/ Sl
OWNER
.t W N S Fq< O R DRESS / d /L b�► 1 �G!A,,
OWNER PHONE (%— O 2-
- d
C * ? ESTIMATED COST$ q 00 CIO
V IS THIS A CONTRACT COST? Yes L__I�o
FEE ENCLOSED$ � .
TYPE OF JOB: � 23
�SOR•COc� New Installation
Alteration/Addition/Repair
obi SOUk�eS
Revised 03/05/10
APPLICATION FOR HVAC PERMIT(Continued from ieverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
❑ UEATING J; I ESIDENTIAL
W'AIC ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY
❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
Air 7-4-kr e :)L. r nl-1 Ire'.1W
2: -c o, 1 G 7 3 A�V- 0 30a -C
TONNAGE 2, COOLING CAPACITY(BTUH) �O Gov
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK .c-n
S' C.-I c fy,- ex, IT
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. _JYPE STATE
SIGNATURE OF APPLICAN _5 DATE I y
Load Short Form Job:
+�+ wrightsoft Date: Jul 02,2015
Entire House By: sam
Andrews Oil Co.
Project Inf• •
For: Sean Anderson
17 Carman drive, South Windsor, Ct 60642
Phone: 860-402-5163
Design Information
Htg Clg Infiltration
Outside db(°F) 8 92 Method Simplified
Inside db(°F) 68 75 Construction quality Average
Design TD(°F) 60 17 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference (gr/lb) 45 27
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make Air temp
Trade Trade
Model Cond V54bd-030kb
GAMA ID Coil c7bam-030u-c
ARI ref no.
Efficiency 80 AFUE Efficiency 0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Low output baseboard 500 Btuh/ft Total cooling 0 Btuh
Total low baseboard 0 ft Actual air flow 1041 cfm
High output baseboard 700 Btuh/ft Air flow factor 0.049 cfm/Btuh
Total high baseboard 0 ft Static pressure 0.00 in H2O
Space thermostat Load sensible heat ratio 0.74
ROOM NAME Area Htg load Clg load Baseboard(ft) Clg AVF
(ft2) (Btuh) (Btuh) Low High (cfm)
1 st. floor add. 276 0 8446 0 0 414
main house 768 0 4654 0 0 228
sunroom 120 0 2994 0 0 147
2nd floor 768 0 5123 0 0 251
Entire House d 1932 0 21217 0 0 1041
Other equip loads 14741 4176
Equip. @ 0.97 RSM 24631
Latent cooling 9031
TOTALS 1932 14741 33662 0 0 1041
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
TM
� Ri ht-Sude Universal 7 0 14 RSU03006 -
,� +�+ wrightsoft g 2015 Jul-02 14 33 10
*--CA, C\Documents and Settings\User\My Documents\wrightsoft HVAC\sean anderson rup Calc=MJ8 Orient Page 1
+`+ wrightsoft Building Analysis : JW02,2015
Entire House By: SM
Andrews Oil Co.
Project Information
For: Sean Anderson
17 Carman drive, South Windsor, Ct 60642
Phone: 860-402-5163
Design Conditions
Location: Indoor: Heating Cooling
Windsor Locks Bradley Field, CT, US Indoor temperature(T) 68 75
Elevation: 180 ft Design TD (°F) 60 17
Latitude: 42°N Relative humidity(% 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 44.6 27.4
Dry bulb(T) 8 92 Infiltration:
Daily range(°F) - 21 ( M ) Method Simplified
Wet bulb(°F) - 73 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Walls 0.0 0 0.0
Glazing 0.0 0 0.0
Doors 0.0 0 0.0
Ceilings 0.0 0 0.0
Floors 0.0 0 0.0
Infiltration 0.0 0 0.0
Ducts 0 0.0
Piping 0 0.0
Humidification 0 0.0
Ventilation 14741 100.0
Adjustments 0
Total 14741 100.0
Cooling
Component Btuh/ft2 Btuh %of load
Walls 1.3 2548 10.0 waves V"11811on
Glazing 32.5 4653 18.3
Doors 10.1 545 2.1
Ceilings 3.4 3876 15.3 �
Floors 0.3 317 1.2
Infiltration 0.5 1026 4.0
Ducts 232 0.9
Ventilation 4176 16.4 Do s
Internal gains 8020 31.6
Blower 0 0.0
Adjustments 0 C.'°4
4
Total 25393 100.0 oar,M
�,i.rahm
Overall U-value =0.127 Btuh/ft2-°F
Data entries checked.
1 -#++- Right-Sune-Universal 7 0 14 RSU03006 2015-Jul-02 14 33 10
ACCA C\Documents and Settings\User\My Documents\WnghtsoR M/AC\lean anderson rup Calc=MJ8 Onent Page 1
+ wrightsoft• Component Constructions : Ju102,2015
Entire House By: sam
Andrews Oil Co.
Project I • •
For: Sean Anderson
17 Carman drive, South Windsor,Ct 60642
Phone: 860-402-5163
Design Conditions
Location: Indoor: Heating Cooling
Windsor Locks Bradley Field,CT, US Indoor temperature(°F) 68 75
Elevation: 180 ft Design TD(°F) 60 17
Latitude: 420N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 44.6 27.4
Dry bulb(°F) 8 92 Infiltration:
Daily range°F) - 21 ( M ) Method Simplified
Wet bulb(° ) - 73 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area u-value Insul R "tg"TM Loss Clg"TM Gain
fP BtuhM--'F W-T/Btuh Stuhff Stuh Btuhff Btuh
Walls
12E-2sw:Frm wall,vnl ext,1/2"wood shth,r-19 cav ins,1/2"gypsum n 627 0.063 21.0 0.00 0 1.06 666
board int fnsh,r-2 ext bd ins,2 x C wood frm s 367 0.063 21.0 0.00 0 1.06 390
w 502 0.063 21.0 0.00 0 1.06 533
all 1496 0.063 21.0 0.00 0 1.06 1588
12C-2sw:Frm wall,vnl ext,1/2"wood shth,r-13 cav ins,1/2"gypsum a 368 0.081 15.0 0.00 0 1.71 627
board int fnsh,r-2 ext bd ins,2'k4"wood frm
16A-30ad:Knee wall,asphalt shingles roof mat,r-2 roof ins,r-30 kw s 145 0.032 30.0 0.00 0 2.29 332
ins,1 IT gypsum board int fnsh
Partitions
(none)
Windows
1 Fc2ows:2 glazing,clr outr,air gas,wd frm mat,clr innr,clr strm, n 60 0.440 0.0 0.00 0 20.4 1224
1/4"gap,1/8"thk a 16 0.440 0.0 0.00 0 62.3 997
s 44 0.440 0.0 0.00 0 33.9 1492
s 15 0.440 0.0 0.00 0 33.9 509
all 135 0.440 0.0 0.00 0 31.3 4221
4A1-2ov:2 glazing,clr b"outr,air gas,irtsulated vinyl frm mat,clr w 8 0.470 0.0 0.00 0 54.0 432
innr,1/4'gap,1/8"thk
Doors
1110:Door,wd pnl type,and strm strm n 17 0.360 1.0 0.00 0 10.1 172
s 37 0.360 1.0 0.00 0 10.1 374
all 54 0.360 1.0 0.00 0 10.1 545
Ceilings
166-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 888 0.032 30.0 0.00 0 1.65 1465
ceil ins,1/2"gypsum board int fnsh
18A-2ad:Rf/cig ceiling,asphalt shingles roof mat,frm cons,r-2 deck 267 0.194 2.0 0.00 0 9.03 2411
ins,1/2"gypsum board int fnsh,10"thkns,r-30 ceil ins
'- -4t- wrightt0c f't Right-Suite"'Universal 7 0 14 RSU03006 2015-Jul-02 14 33 10
)im C Documents and SettingsWserWy Documents\Wrightsoft HVAC%sean anderson rup Cal=MJ8 Orient Page 1
Floors
II 9C-Obscp:Fir fbor,ftm flr,10'thlms,carpet flr fnsh,r-2 ext ins,tight 768 0.368 11.0 0.00 0 0.41 317
bsmt ovr,r-11 wall insul
^*= wrigtitsoft- Right-SuRe"'Universal 7.0.14 RSU03006 2015-Jul-02 14:33:10
C.1Doouments and Settmgs\User\My DocumentslWrightsoft WACtsean anderson.rup Calc=MJ8 Orient Page 2
Project Summary Job:
wrightsoft Project Date: Jul 02,2015
Entire House By: Sam
Andrews Oil Co.
Project • •
For: Sean Anderson
17 Carman drive, South Windsor, Ct 60642
Phone: 860-402-5163
Notes:
Design Information
Weather: Windsor Locks Bradley Field, CT, US
Winter Design Conditions Summer Design Conditions
Outside db 8 °F Outside db 92 °F
Inside db 68 °F Inside db 75 °F
Design TD 60 °F Design TD 17 °F
Daily rangge M
Relative humidity 50 %
Moisture difference 27 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 0 Btuh Structure 20985 Btuh
Ducts 0 Btuh Ducts 232 Btuh
Central vent(225 cfm) 14741 Btuh Central vent(225 cfm) 4176 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 14741 Btuh Use manufacturer's data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 24631 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3824 Btuh
Ducts 1038 Btuh
Heating Cooling Central vent(225 cfm) 4169 Btuh
Area (ft2) 0 1932 Equipment latent load 9031 Btuh
Volume (ft3) 0 16560
Air changes/hour 0.61 0.20 Equipment total load 33662 Btuh
Equiv.AVF (cfm) 0 55 Req.total capacity at 0.70 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Air temp
Trade Trade
Model Cond V54bd-030kb
GAMA ID Coil c7bam-030u-c
ARI ref no.
Efficiency 80 AFUE Efficiency 0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Low output baseboard 0 ft Total cooling 1041 cfm
Total low baseboard 700 Btuh/ft Actual air flow 0.049 cfm/Btuh
High output baseboard 0 ft Air flow factor 0.00 in H2O
Total high baseboard Static pressure 0.74
Space thermostat Load sensible heat ratio
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
,� +I f wr.gFitsoR Right-Suite—Universal 7 0 14 RSU03006 2015-Jul-02 14 33 10
ACCI+ C\Documents and Settings\UsertMy Documents\Wrightsoft HVAClsean anderson rup Calc=MA Orient Page 1
AED Assessment Job:
wrightsoft+ Date: Jul 02,2016
Entire House By: son
Andrews Oil Co.
Project • •
For: Sean Anderson
17 Carman drive,South Windsor,Ct 60642
Phone:860-402-5163
Design Conditions
Location: Indoor: Heating Cooling
Windsor Locks Bradley Field,CT, US Indoor temperature(OF) 68 75
Elevation: 180 ft Design TD(OF) 60 17
Latitude: 420N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(grAb) 44.6 27.4
Dry bulb(OF) 8 92 Infiltration:
Daily range(OF) - 21 ( M )
Wet bulb(OF) - 73
Wind speed(mph) 15.0 7.5
Test for • - • Exposure
Hourly Glazing Load
8,000
7,000
6,00
m 5,000
o
0
Cb 4,000
N
m
3,00
2,000
1,000
0
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
/ Hourly Average / AED limit
Maximum hourly glazing load exceeds average by 28.9%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
!!�L -pp- wrightsof'r Right-Sufte"Universal 7.0.14 RSU03006 2015-Jul-02 14 33 10
CADocurnents and Settings\User\My Documents\Wrightsott HVAC\sean anderson rup Calc=MJ8 Orient Page 1
- -wrightsof * Right-J®Worksheet Job:
Entire House Date: JuI 02,2015
Andrews Oil Co. By: sam
1 Room name Entire House 1 st.floor add.
2 Exposed wall 187.0 It 43.0 ft
3 Ceiling height 8.6 It d 12.0 It cool only
4 Room dimensions 12.0 x 23.0 ft
5 Room area 1932.0 ft' 276.0 W
Ty Construction U-value Or HTMI Area (ft2) Load Area (ft2) Load
number (Btuh/112'F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (11) (Btuh)
Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool
6 12E-2sw 0.063 n 0.00 1.06 704 627 0 666 112 112 0 119
L_Gp 1F-c2ows 0.440 n 0.00 20.40 60 0 0 1224 0 0 0 0
1110 0.360 n 0.00 10.10 17 17 0 172 0 0 0 0
T 12C-2sw 0.081 a 0.00 1.71 384 368 0 627 0 0 0 0
11 -G 1 F-c2ows 0.440 a 0.00 62.29 16 0 0 997 0 0 0 0
V►/ 12E-2sw 0.063 s 0.00 1.06 448 367 0 390 112 95 0 101
L Gp 1F-c2ows 0.440 s 0.00 33.90 44 0 0 1492 0 0 0 0
1110 0.360 s 0.00 10.10 37 37 0 374 17 17 0 172
W 16A-30ad 0.032 s 0.00 229 160 145 0 332 0 0 0 0
Y-G 1F-c2ows 0.440 s 0.00 33.90 15 0 0 509 0 0 0 0
W 12E-2sw 0.063 w 0.00 1.06 510 502 0 533 276 268 0 284
t-G 4A1-2ov 0.470 w 0.00 54.01 8 0 0 432 8 0 0 432
C 16B-30ad 0.032 - 0.00 1.65 888 888 0 1465 0 0 0 0
C 18A-2ad 0.194 - 0.00 9.03 267 267 0 2411 267 267 0 2411
F 19C-0bscp 0.368 - 0.00 0.41 768 768 0 317 0 0 0 0
F 22A-tpl 0.989 - 0.00 0.00 396 0 0 0 276 0 0 0
6 c)AED excursion 0 82
Envelope loss/gain 0 11939 0 3601
12 a) Infiltration 0 1026 0 232
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 14 3220 4 920
Appliances Q 1200 4 4800 3 3600
Subtotal(lines 6 to 13) 0 20985 0 8353
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 20985 0 8353
15 Dud bads 0% 1% 0 232 0% 1% 0 92
Total room bad 0 21217 1 0 8446
Low4High Baseboard/Cool Air 0 0 1041 Of 0 414
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
+- -vf*- RightSude" Universal7.0.14RSU03006 2015-Jul-02 14 33.10
��►�Q%Documents and SettingsWser\My Documents\Wrghtsoft HVAC\sean anderson nip Calc=MA Orient Page 1
' -�-wrightsofC Right-J®Worksheet Job:
Entire House Date: Jul 02,2015
By: seta
Andrews Oil Co.
1 Room name main house sunroom
2 Exposed wall 0.0 ft 32.0 ft
3 Ceiling height 8.0 ft cool only 8.0 ft cod only
4 Room dimensions 32.0 x 24.0 ft 10.0 x 12.0 ft
5 Room area 768.0 ft' 120.0 ft'
Ty Construction U-value Or HTM Area (ft2) Load Area (ft-) Load
number (Btuh/t�•F) (Btuhl112) or perimeter (It) (Btuh) or perimeter (ft) (Btuh)
Heat Cod Gross NMIS Heat Cod Gross NMIS Heat Cool
6 V)I 12E-2sw 0.063 n 0.00 1.06 256 215 0 228 80 68 0 72
IF-c2ows 0.440 n 0.00 20.40 24 0 0 490 12 0 0 245
1110 0.360 n 0.00 10.10 17 17 0 172 0 0 0 0
Y�-(' 12C-2sw 0.081 a 0.00 1.71 96 88 0 150 96 96 0 164
11 1F-c2ows 0.440 a 0.00 62.29 8 0 0 498 0 0 0 0
VI/ 12E-2sw 0.063 s 0.00 1.06 256 204 0 217 80 68 0 72
I�---GD 1Fc2ows 0.440 s 0.00 33.90 32 0 0 1085 12 0 0 407
1110 0.360 s 0.00 10.10 20 20 0 202 0 0 0 0
16A-30ad 0.032 s 0.00 2.29 0 0 0 0 0 0 0 0
t--G 1F-c2ows 0.440 s 0.00 33.90 0 0 0 0 0 0 0 0
W 12E-2sw 0.063 w 0.00 1.06 42 42 0 45 0 0 0 0
r G 4A1-2ov 0.470 w 0.00 54.01 0 0 0 0 0 0 0 0
C 1613-30ad 0.032 - 0.00 1.65 0 0 0 0 120 120 0 198
C 18A-2ad 0.194 - 0.00 9.03 0 0 0 0 0 0 0 0
F 19C4Obscp 0.368 - 0.00 0.41 768 768 0 317 0 0 0 0
F 22A-tpl 0.989 - 0.00 0.00 0 0 0 0 120 0 0 0
6 c)AED excursion -22 25
Envelope loss/gain 10 3381 01 1182
12 a) Inriftration 0 302 0 119
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants 0 230 4 920 2 460
Appliances® 1200 0 0 1 1200
Subtotal(lines 6 to 13) 0 4603 0 2961
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 4603 0 2%1
151 Dud loads 0%1 1% 0 51 0% 1% 0 33
Total room load 0 4654 0 2994
L.ow4High Baseboard/Cod Air 0 0 228 0 0 147
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
-f}+- wr/pFsboft RightSuite^ Universal 7.0.14 RSU03006 2015-Jul-02 14.33:10
. A C:1Documents and SdtingsUJseAMy DocumeMs\Wnghtsoft WAC%sean anderson.rup Calc=MJ8 Orient Page 2
- +-wrightsoft Right-M Worksheet Job:
Entire House Date: Jul 02,2015
Andrews Oil Co. By:
Sam
1 Room name 2nd floor
2 Exposed wall 112.0 It
3 Ceiling height 8.0 ft cool only
4 Room dimensions 24.0 x 32.0 It
5 Room area 768.0 ft2
Ty Construction Ll-value Or HTM Area (ft-) Load Area Load
number (Muh/ft2-1) Mtuhlft2) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cod Gross WP/S Heat Cool
6 V)f 12E-2sw 0.063 n 0.00 1.06 256 232 0 246
1 F-c2ows 0.440 n 0.00 20.40 24 0 0 490
1110 0.360 n 0.00 10.10 0 0 0 0
Y1! 12C-2sw 0.081 a 0.00 1.71 192 194 0 314
11 ►-G 1 Fc2ows 0.440 a 0.00 62.29 8 0 0 498
L12E-2sw 0.063 s 0.00 1.06 0 0 0 0
C 1 F-c2ows 0.440 s 0.00 33.90 0 0 0 0
D 1110 0.360 s 0.00 10.10 0 0 0 0
ILG16A-30ad 0.032 s 0.00 2.29 160 145 0 332
1 F-c2ows 0.440 s 0.00 33.90 15 0 0 509
W 12E-2sw 0.063 w 0.00 1.06 192 192 0 204
-G 4A1-2ov 0.470 w 0.00 54.01 0 0 0 0
C 168-30ad 0.032 - 0.00 1.65 768 768 0 1267
C 18A-2ad 0.194 - 0.00 9.03 0 0 0 0
F 19C-0bscp 0.368 - 0.00 0.41 0 0 0 0
F 22A4pl 0.989 - 0.00 0.00 0 0 0 0
6 c)AED excursion -84
Envelope loss/gain 0 3775
12 a) Infiltration 0 372
b) Room ventilation 0 0
13 Intemal gains: Occupants® 230 4 920
Appliances Q 1200 0 0
Subtotal pines 6 to 13) 0 5067
Less extemal load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 0 5067
15 Duct toads 0% 1% 0 56
Total room bad 0 5123
I I Low4High Baseboard/Cool Air 0 0 251
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
*}+- wr��titsof`t' RightSuite" Universal 7.0.14 RSU03006 2015Jul-Jul 14.33:10
C:\Documents and Settings%UserWy DocumentslWnghtsoft WAC%sean anderson rup Calc=MJ8 Orient Page 3
Eiectric # APPLICATION FOR BUILDING PERMIT
Plumbing# 17 Carman Road
HVAC# 11000348 Date:
Sp Estimated Cost $`7,-
FINAL APPROVALS $ .
Permit Fee
Building COMPLETE RED BOXED AREAS $ 2c,
Occupancy Fee $
Engineering TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit I x ► t SIGN ON REVERSE SIDE
Appr.forCO. � I Total Fee $ f
TO THE BUILDIN!'�G ARTMENT, TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 30q
The undersigned hereby applies to do work according to the following:
Applicant t c w s m WoAeir, ocation of Work / 7 C'� +A -J c) , Lot No.
Applicant's Address 4101 Tel # (olo-8 74- So 00
Town P^ _ Zip I q o i --4 Lic.# (ool 4-s-+`� 7
Owner Architect
Owner's Address V 7 Architect's Address
Soyrit (�//.✓4SOG - - - _ Zip_ - -- Zip
Sq. Ft.New Area: 1 st FI. 2nd A. 3rd FI. _ Total New Area
/
Purpose
of this permit �� oaf - %E off Z L,t tig--c. s g r t A4 5
Etc te/L �jN/t!lol�S
City Water❑ Well❑ Septic System 0 Sewer❑ oiioo83p
Ins: HO SP Cert. Area Basement Garage
Approved by j I Date Use Group Construction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in wh ding an its u I ed.
Signed
I hereby apply for a Certificate of Occupancy for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
NA110NAL t-fi-AVOUARILU� aml ionnikir
21,0! Chester PA!9L I'POVIER -274
20 2r,1!1
888-REMODEL -
CUSTOM REMODELING AND IMPROVEMENT AGREEMENT CT.fit(;
Soyer's Information 1 30-27411
Sean Anderson s PrcleCT t4tilnbor July 20.2011 1
T
lonnifar Anderson I (0 60 1644-1 I's 1(Nonce)
17 carmi'n PCI
CT,0504 2
County;Tollond
Township:
Buyer(s)listed above hereby jointly and severally agrees to purchase the goods and/or services listed on the
accompanying specification sheets,in accordance with the prices and terms described on the front arid the reverse
of this agreement and any specification sheets (coliectively,this"Agreement").This Agreement rupresents a cash
sale of goods and services.Guyer(s)agrees to pay in cash the cost of the goods and services purchase.d as
described herein,regardless of timing or approval of any other Buyer(s)may seek far their purchase
Purchase Prire: $7.784.57 Pre Installation inspection Date(s):
Down Payment: $0.00 -E-st;maled Project Start,
4 to 5 vcmk-,-
Balaqce Due on Substantial $7.784.57
Completion: Estimated Project Completion*
I to 2days
Method of Payment Credit Card
Guyer(s)herebyacknowI96ges receipt of a copy of the pamphlet,"Renovate Right,Important Lead Hazard
Information for Families,Child Care Providers aiid Schools-.informing Buyer(s)of the potential risk of lead hazard
exposure from renovation activity to be performed in Buyer's home,at the address written above.Buyer(s)received
this pamphlLA oh the date of this Agreement,before commencement of work.
It is agreed.and understood by and between the parties that this Agreement constitutes the entire understanding
between the parties,and there are no verbal understandings changing Or modifying any of the-terms
terms of this
Agreement.-Buyer(s)hereby acknowledges that Buyer(s)1)has read the entire Agreement and has received a
completed,signed,and dated copy of this Agreement,including the two attached Notice of Cancellation forms,on the
date first written above and 2)was orally informed of his1her right to cancel this transaction,
This Agreement Includes all current discounts and promotions.
Power Ho cling Group uy r(s) Buyer(j)
'a
gfia
��iqna e of Sales Representative Signature Si a Vr d
Johann Manss Sean Anderson ennifer Anderson
I have faad and rocolved each page of this 4 pope agreptriviL
YOU.THE DUYER(S).MAY CANCELTHIS TRANSACTION ATAW?TIME PRIOR TO MIDNIGHT OFTHETHIRD BUSINESS DAY AFTER THE DATE OF
THIS TRANSACTION. SECTHE NOTICE OF CANCELLATION FORIA FOR AN EXPLANATION OF THIS RIGHT,
July 20,20 1122.22 I f f ��JJ)i ll ''II`` i�II ##�!!
Page 1 of 4
NATIONAL HFADOUARTERS Sean and Jennifer Anderson
2501 Seaport Drive,Chester,PA 19013 POWER 30-27411
c 888-REMODEL July 20.2011
. ,
Project Specifications CT-HIC.0624357
Roofing: Whole House i 1850.0"0.0"
Roofing:Whole House 1 1850.0"x1.0"
ROOFING:Models GAF Styles Architechtural Shingles Types None Con figs No Intake Boosters
OPTIONS:Color Pewter Gray l Removal Standard Shingle l Installation Details None
GAF MATERIALS
CORPORATION
Roofing: Top of Home 1 45.0"x1.0"
Roofing:Top of Home 1 45.0'xl.0"
ROOFING:Models GAF Styles Cobra Ridge Vent Types None Configs None
OPTIONS:Color Pewter Gray l Installation Details None
GAF MATERIALS
CORPORATION
t
.I
i
l
l
July 20,2011 22:22 Page 2 of 2 "
IIIllllllllllllll�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
._-__ __
A' FS-.
POWER
Home Remodeling Group
WINDOWS • SIDING ROOFING DOORS
DATE:
TO: S o 'r .+ �ic//-✓/J S d-L
ATTN: Town Building Inspector
RE: PERMIT AUTHORIZATION LETTER
Dear Sirs:
In accordance with Public Act 91-95,this letter serves as written authorization and notification
that GoFor Services,Inc.and it's employees and agents have the authority to represent us in the
procurement of permits and pertinent documentation on our behalf.
This letter or a photocopy thereof may be regarded by any building official as it's authority to
recognize GoFor Services,Inc.as our authorized Agent to sign on our behalf applications for
permits and any other related documents that may be required by you,and we agree that,for all
purposes,we and not GoFor Services or it's employees and agents shall be deemed to be the signer
of any such applications and related documents.
Project Type: 10E o v F
Location: 5 EA ` `
��G l�Ti/ li/�/-✓iJ SG'-2
-7 -11 /
Authorized Agent Gofor Services,Inc. �N
Service Agent Name
Very truly yours
Licensee ignature Printed Name& License Number
2501 Seaport Drive • First Floor • Chester, PA 19013
888.REMODEL 9 PowerHRG.com
INSPECTION FIELD SHEET 12/22/11
Printed by Peart, Dayshell 08:48 05 •
INSPECTION: 41686 FINAL PERMIT:
STATUS:
APPLICATION: 201100830
LOCATION: 17 CARMAN ROAD
SOUTH WINDSOR
PROPERTY ID: 17400017
OWNER: ANDERSON SEAN P & JENNIFER M
CONTRACTOR:
REQUEST BY:
DESCRIPTION: RE ROOF. TEAR OFF ONE LAYER. 18 1/2 SQUARES, GAF, TIMBERLINE
WORK ORDER:
INSPECTOR: ROSE RESULT: PASS
REQUESTED: 11/07/11 PRIORITY:
SCHEDULED: 11/07/11 PM COMPLETED: 11/07/11
UNPAID FEES: 00 Date Time
TIME: TRAVEL ONSITE
COMMENTS:
1ST INSP TO REAR SECTION OF ROOF
.40
5EMC.TANK
—75ucK PAVED
vb<
r-t S'1 E) E 14 c -E
lo.s
uj
C A.-K K A R.- K 0 A D
—
- P L 0 T. P L A
--- Vt = 30- o I ,_
K
MK- 4 MK5, ALLAN K. 5CHUb � KT
1-1 CA KM AN ROAD
SOUTH W I RD 5 .0 -K I CONN.
ALAN r-, WIEDIE , ARCHITECT 13OL70N C-T.
U E C E � I E
MAY 0 9 2008
0
South Windsor
BUILDING DEPARTMENT
=E 8b�11�hiG G✓t. i�,Hti ...
s of the proposed it,iiding or aite ra�:l-+s .,•
. . .!.ed at
E:`ther with amendments stated in application
<I with plan and 1 agree to comply with all Tonlr,;
!.,ding and state laws and such orders as shel; t,
•—d by the Building Department during pendene.
:his appllcati n and f al is nco of a bulldina
A, rmit.
,YV vned
s pis s a ed sub .r. o the condition thn"
!ers a - ordin n s re gu tiny ding 5he0 t•r
m p!Icd .ith.
.,ndition ily Approved These filed with
Ruitding Inspector Clerk
•re N.
CERTIFICATION OF ZONING C010PLIANCE
Propccn-i buildin0(s), use(s)
p„-- :n
cc: currer�i r
re,, 's and
m,
Date
g �n ement O:iicer
o �QI
co
t �,-.5EP_TIC TANK
lqlx 16 mncK PAVED
-TFRKXCE
cl
K--E'-51 1) F- 14 C E
O
C F\ MAR- ROA D
P L 0 T. P L A. _ ,_
- - ll = 30- o
F 8 K
MK. 6 MKS. ALLAN K. 5CHUb � KT
1-1 CARMAN R 6 A D
SOUTH W I R D S O R I CONN.
ALAN C. WIEDIE I ARCH ITECT BOL-TON I C.T.
NU 0 6 1991
South Windsor
BUILDING DEPARTMENT
�r:it 1FICATION OF ZONING COMPLIANCE
NCE
D«k as Proposed
ithis),plan(s) andfor appearrlsls to be in
iy►X,b' ass l7 CJa1�M�M .�
conformance with current South Windsor -
regulations. Variances and special exceptions
may apply.
Date
zoning Enforcement Officer
co
10
qoo
0
5EP_TIc.TAN K
_HRtcK PAVED _
TERK)kCE
R=-E510E9c E
10.5�
w
O
J
W
Q
cc
t?
T7.d0I._
i
C A. R MAK R 0 A D
P L 0 T. _ _P IIL Al _ Nl--
= 30
F 8 K -
MR. 6 MKS. ALLA N K. S C H U b � RT
17 CA KM AN ROA D
SOUTH WIRD50 _tZ , CONN.
A!AN C. WIEDIE ARCH ITECT 50L70N I CT. `�/7a
Electric # , _ APPLICATION FO k" MIT
Plumbing# 17 17Carman Road D : MAY 9 2008
HVAC # c, , ,
800224
Sprinkler# i,. _�/A _1 _ Esg�{pli�tPAR
FINIALI ! 1 �6SE� - -- -- --- --- -- -; Permit Fee $
Buildi „� COMPLETE RED BOXED AREAS
Engineeri I Occupancy Fee $
Affidavit PA TYPE OR PRINT ONLY Eng. Insp. Fee $
A r. for co. I �', ► SIGN ON REVERSE SI
DE PP Total Fee $ i n�
CGS 29-393 - —TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $
The undersigned hereby applies to do work according to the following: 1'�'�
Applicant 1 Location of Work Lot No. tt
r
Applicant's Address Tel.# , -"
Town Yl. M i# 0 C Zip -Lic.#
Owner _Architect
Owner's Address Architect's Address
Zip Zip-
Sq. Ft. New Area: 1 st FI. 2nd FI. 3rd FI. Total New Area
Purpose of this permit
90M 6114
C�Wate Well❑ Septic System❑ Sewe;x
Ins: HO S Cert. Area Basement Garage
Approved by Date Sr'k�8 Z Use Group Construction Type
Revised 8102
0(P L4
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this buildia and is use is allowed.
Signed _
1 hereby apply for a Certificate of ccu for the work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
PERMIT CLOSED
PER: PPS 17-176
AND
c as 29-393
Cox
NW 0►'AL P DEC((ADD TO TO'1?DIMENSION)
1J 71ff$SAAWD1W0POQ ASDSWED/N INE��pow
/NAPXq9DAAND: DECKS ARE OPTIONALPOOL 1NVIN F'STANDAR00 (ANSIINS" ' ARE AVAILABLE
2)OEX3AREDE9QWVM70 WN OF1G01815F. F MODELS.
3)F&CFW#fWTAVDA2fa11 G 70130160771t,r
4JN1 AFIRNINGSIN 1NEffIVCf AZ LESS
0PROl WfYE0CRE ZEDSAll RfraUIREdlfMS0F2CSECT.310
RampoX DECKS ARE E
SWNG•UP SU LOCKING LADDER ��10NA1LL� 1�STRAPS IN POOL
,{VAILABLE[� D
ILL POOL MODELS. C
�,. IN POOL
p LADDER
Sw%tip SELF LOCKING LADDER
ADD a-�TO V DIMENSION O
DECK SURFACE TO FENCE TOP RAIL
4r ADD 5.8'TOW DIMENSION �, OR
OR 52"6? 1111 mill
0 314'
J •;. ..I I Y Y1Rd}.a _{+. K• .t 1. yf.�,-.•)-K, t=.
-UNDISTUWEARTH
_- ES t�[LaH1if r• ST ;r{ COPING OPTIONAL
NOT ALL POOL ;: WALKDECK
1a Z35D z5W IT SIZESARE NULTIPORTVALVE RETURN WALKDECK
11 3,650 000 17.6' AVAILABLE ON HIGH RATE INTAKE SUPPORT
16 S,300 5,750 15-0' ALL MODELS FLIER
1 N 7,600 a250 11-T SKIMMER DELTA OR
111351) . MIS- 21'-D'
24 1 A550 t 1200 POOL WALL STEALTH
24'HOP: 1ISO 1300 2?0 WASTELINE UPRIGHT
2T 17150 1 550 2T-0' PAP& SAND \ FOOTING
2THOP. 1%300 23,100 2T40' MOTOR BASE BLOCK
30' 21150 2�900 3a-0" •-...
OVA.SI<FS 1GAL 6rGAL C I D E TIE CROSS SEC DON OF MID SEC DON
S,950 6,4
13W 00 12'-6' if-V V4 fJ11R4n 11C I STRAP FOR 0Vk POOLS
1m 7,050 7.0 1?•6' 211 IT-I? J ����.,, Seal S.E. CONSULTANTS, INC.
13' 5' a 8,850 17�6' 24�6' 1T�E
Imc k350 1%100 W 24-T 20'-0' tiy'cGf'4
DELAIR GROUP LLC.
15W HOPPER 1 Q400 11,150 15 0' 24'-0' 29-T
a* = 86DO RIVER ROAD
_
15'>QO' IZ 50 13,050 16-T 94r 2V-T PEN.23816 , � � DELAJ NEW.IERSEY08114.3396
NkSIR JUKILEIpNG
WHOPPER 13,2b0 Km15-0' 30'-0' 2a-0'
-
18'Xi3' 15,700 17,000 I v_v 3 r 2TV z°"°�NFss/Q N AL,� ,�`�,•° WMm - VI�fAhpIYIES
SPEC420 11C20 S 1 B'�Q3'HOPPER 11,2DD 18,500 18'-0' 33'-0' 234' "•,,,,�„� �
JD J
SmartPool Page 1 of 2
Aw
POOL O,
ABOVEGROUND POOL ALARM SYSTEM #PE12
• Patented Sub-Surface Propagation Wave Detector
• Sensor Placed Below Water Surface Eliminates False Alarms Due to Wind, Rain, etc.
• Detects Objects 15 Ibs or More
•Adjustable Sensitivity
• 120 dB Alarm Siren (1.5" Stainless Steel Speaker) at Poolside
• Tested to UL 464 and CSA_C2.2.2 Standards
• Child-Proof ON/OFF Switch w/Audio Indicator and Battery Strength Check Chirp
• Automatic Low Battery Check -Chirps Every 60 Seconds
• Recommended for Pools up to 24' Round
or 16'x 32' Oval (Larger Pools Require an
additional Alarm)
•Automatic Reset in 3 Minutes
• Power Check Test Button
r ="F • Sensor Mounts Under Top Ledge/Siren
` on Vertical Support Post Outside of Pool
• Fully Waterproof Construction
• Runs on 4 AA Batteries (not incl.)
• • Bilingual Installation/Operation Manual
• (English/French)
`-V
` • Bilingual 4-Color Box (English/French)
http://smartpool.com/website/POOLEYE/pe 12.htm 3/21/2008
Electric # APPLICATION FOR BUILDING PERMIT
Plumbin # 17 Carman Road
HVAC ED 12000722 FDate:
Sprinkler
FINAL R S Estimated Cost $ 3000 "
Permit Fee $
Building COMPLETE RED BOXED AREAS Occupancy Fee $
Engineering CGS TYPE OR PRINT ONLY Eng. Insp. Fee $
Affidavit Appr.for CO. ► SIGN ON REVERSE SIDE
Total Fee $ y�
TO THE BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR, CT (Additional Cost) $ 1 �S
The undersigned hereby applies to do work according to the following:
Applicant 50L* rjjn W.e. LocationofWork 17 COMI fl Lot No.
Applicant's Address I I S7 Park End Dr Tel # N400 t+47—'7172
Town ��SOGKe , R:[ Zip 5 Lic.# 063Ht56j!5
Owner TQ�nj. -! Sea11 And2'1r_Zn Architect
Owner's Address 17. cGtrftn RA Architect's Address
S . Windsor, CT: Zip 6604Z Zip_
Sq. Ft. New Area: 1 st FI. 2nd Fl. 3rd FI. Total New Area
Purpose of this permit TnS!W1.-(2� fgcenwinli- ,VindoLt;5
City Water❑ Well ❑ Septic System ❑ Sewer❑
Ins: HO S e Area Basement Garage
Approved by `" Date 5 .4• 3— Use Group Construction Type
Revised 1108
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required
distances from all other zones and is located in which this building and its use is allowed.
Signe
1 hereby apply for a Certificate o Oc cy for work described in this application for the permit.
Signed
DO NOT WRITE BELOW THIS LINE
INSPECTION COMMENTS
R IT L
Ir-
Pq 17-176
CGS 29,323
06/21/2021 08:48 TOWN OF SOUTH WINDSOR P 1
morganamiddleton APPLICATION PROFIL$ piappent
GENERAL APPLICATION
Application ref 201201691 Fee Effective Dt 12/19/2012
Department 1440_- BUILDING DEPARTMENT
Location 17 CARMAN ROAD
Parcel 17400017
Cross streets
Add'1 loc desc
Municipality SOUTH WINDSOR
Subdivision Lot
Existing use RESIDENTIAL LOT
memo
Current Zoning RESIDENTIAL A-20
Flood zone
Applicant GENERAL CONTRACTOR
Proj/Activity BUILDING-PERMIT _QNLY
Class of work
Description INSTALL TWO REPLACEMENT WINDOWS.
NO STRUCTURAL CHANGES.
Proposed use RESIDENTIAL LOT
memo
Proposed zoning RESIDENTIAL A-2Q
Flood zone
Non-conforming N
Applic received 12/19/12
Estimated cost 0
Estim start/end
Actual start/end 06/21/21
Impervious Surf
Assigned to
Status COMPLETE
Status code desc COMPLETE Multiple submissions N
Next action Government owned N
memo
Ordinance ref
Reason for app
Parent app Point in time fee effective date
Fee expiration date
PROGRESS
Prerequisites Approved 1 of 1
Restrictions/Hazards Cleared 0 of 0
Plan Reviews 0 of 0
Department/Board Reviews 0 of 0
Permits Issued/Completed I of 1
Inspections 0 of 0
Permit Fees Paid 0 of 0
Miscellaneous Charges Paid 0 of 0
Work Orders Paid 0 of 0
06/21/2021 08:48 TOWN OF SOUTH WINDSOR IP 2
morganamiddleton APPLICATION PROFILE piappent
Application ref: 201201691 (continued)
ROLES/NAMES
Role Name/Address
OWNER ANDERSON SEAN P & JENNIFER M
CID : 590902 17 CARMAN RD
MANCHESTER, CT 06040
GENERAL CONTRACTOR SOUTHERN NEW ENGLAND WINDOWS
CID : 637117 10 RESERVOIR ROAD
Phone: 1-401-447-7172 SMITHFIELD, RI 02917
BUILDING CONSTRUCTION
No Building Construction detail was found.
PREREQUISITES
Prereq Action Dept Needed By Approved By Status
BUILDING D APPROVAL 1440 12/26/12 ROSE 12/26/2012
PERMITS
Type Permit Number Status Issued Fee Unpaid Amt
BLDGPERMIT 12000722 ISSUED 12/26/12 45.00 .00
AUDIT HISTORY
Department Action Source Created by
Date Comments
Application status change APP morganamiddleton
06/21/21 See text
1440 - BUILDING DEPA Permit mailed on 12/26/12 APP dayshelllforeshaw
12/26/12 Permit number 12000722
1440 - BUILDING DEPA Permit issued APP dayshelllforeshaw
12/26/12 Permit no 12000722 - BLDGPERMIT, PAID
1440 - BUILDING DEPA Prerequisite approved APP dayshelllforeshaw
12/26/12 BUILDING DEPT PREREQ on 12/26/12
1440 - BUILDING DEPA Permit payment collected APP dayshelllforeshaw
12/19/12 Payment collected on permit BUILDING PERMIT B
1440 - BUILDING DEPA Application entered. APP dayshelllforeshaw
12/19/12
** END OF REPORT - Generated by Middleton, Morgan **
11000348 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 07/28/11
GIS ID: 17400017 FEE: 120.00
MUNIS APPLICATION# 201100830 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: POWER HOME REMODELING GROUP,INC. ADDRESS: 17 CARMAN ROAD
ADDRESS: 2501 SEAPORT DRIVE f' OWNER: ANDERSON SEAN P&JENNIFER M
SUITE B 110 6 17 CARMAN RD
CHESTER,CT 19013 h' 3 MANCHESTER,CT 06040
DESCRIPTION OF WORK: RE ROOF.TEAR OFF ONE LAYER. 18 1/2 SQUARES,GAF,TIMBERLINE
SHINGLES. ;
- , wT
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE,WITH THE APPLICATION AND PLANS'APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
7/28/2011 3:13 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
12000722 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER BUILDING PERMIT
DATE: 12/26/2012
GIS ID: 17400017 FEE: 45.00
MUNIS APPLICATION# 201201691 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: SOUTHERN NEW ENGLAND WINDOWS' ADDRESS: 17 CARMAN ROAD
ADDRESS: 1137 PARK EAST DRIVE OWNER: ANDERSON SEAN P&JENNIFER M
WOONSOCKET,RI 02895. 17 CARMAN RD
MANCHESTER,CT 06040
DESCRIPTION OF WORK: INSTALL:TWO REPLACEMENT WINDOWS.,
NO STRUCTURAL CHANGES..
f
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE-WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
12/26/2012 10:09 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE
1500282 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 07/22/2015
GIS ID: 17400017 FEE: 75.00
MUNIS APPLICATION# 201500865 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: ANDREWS OIL CO. ADDRESS: 17 CARMAN ROAD
ADDRESS: 136 RYE STREET OWNER: ANDERSON SEAN P&JENNIFER M
SOUTH WINDSOR,CT 06074 17 CARMAN RD
MANCHESTER,CT 06040
DESCRIPTION OF WORK: ADDING AIR CONDITIONING TO EXISTING SYSTEM.
CONDENSER AND A-COIL.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
7/22/2015 1 1:37 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE