Loading...
HomeMy WebLinkAbout169 MASKEL RD APPLICATION FOR ELECTRICAL PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT � ��c)A o cog APP O 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 D to Building Inspector Application must be printed or typed FEE SCHEDULE / Lo ation of Job: $041,000=$15.00 �C� -Zf 0e<0 Over$1,000= I Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS ,^J APPLICANT'S PHONE#/ OWNER /1 / q Ow N 3 Fq� OWNER ADDRESS OWNER PHONE 9��o 71 ESTIMATED COST$ C ` IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ Qp V TYPE OF JOB: �7 K-�} ' 1 1 , �SOR-CO New Installation Alteration/Addition/Repair Revised 03/05/10 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑ RESIDENTIAL CURRENT USE AND OCCUPANCY ❑ BUSINESS ❑ ASSEMBLY FUTURE USE AND OCCUPANCY ❑ EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑ FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑ MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE add/-O SIZE OF MAIN CONDUCTORS NUMBERS OF METERS / NUMBERS OF DISCONNECTS AND RATINGS NUMBERS OF PANELS NUMBERS OF DISCONNECTS REQUIRED? ❑ YES ❑ NO NUMBERS OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK /OO✓�, ��_.e dim l� �.���/ � � THE UNDERSIGNED NEARBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFOR- MANCE OF SUCH WORK CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT �i' — DATE --Zz z/3 APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 1 S6 6 3(o I App O 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspe r Application must be printed or typed FEE SCHEDULE !lq L�cationpof Job: $041,000=$15.00 Over$1,000= Street No. S Lot No. $15.00 per$1,000 _ or any fraction thereof Tenant Designation Apt.No. APPLICANT d/G S 0 C �Q%7/VG�1 APP ICTT ADDRESS C Sp c G6 C 2 APPLICANT'S PHONE# <P?�O 6P7 C OWNER e�,,A/I 'f OWNER ADDRESS OWNER PHONE O = ESTIMATED COST$ S0 O. G ,.1 U IS THIS A CONTRACT COST? Yes d"'No FEE ENCLOSED$ ° TYPE OF JO ) 0R•CO New Installation Alteration/Addition/Repair 'oLol 5b►2 DZ Revised 03/05/10 APPLICATION FOR IIVAC PERMIT(Continued from ieverse side) TYPE OF SYSTEM: TYPE OF BUILDING: Cf HEATING RESIDENTIAL ❑ A/C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. WrHYDRONIC ❑ WARM AIR ❑ UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) f�i t 6d"�t GROSS HEATING CAPACITY(INPUT-BTUH)�00�GOd NET RATING(OUTPUT-BTUH) TYPE OF FUEL IL-GPM OIL TANK LOCATION: ❑ INSIDE ❑ OUTSIDE CAPACITY GAS-INPUT r9 LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLIIC/CATION) FURTHER DESCRIPTION OF WORK (�v7fAi^/ fwdlt <:�W /!!��� � �v Jet• THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. ,:5 CONTRACTORS LICENSE NO. TYPE Q STA SIGNATURE OF APPLIC DATE v ��� �-�}- Load Short Form Jo": ' I" wrightsoft' Date: 08/29/2015 Entire House By: sam Andrews Oil and Gas Services Inc 136 rye street, south wndsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scamprtelh@outlook corn License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 Design Information Htg CIg Infiltration Outside db(°F) 8 92 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 62 17 Fireplaces 1 (Average) Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 26 27 HEATING EQUIPMENT COOLING EQUIPMENT Make ECR INTERNATIONAL Make n/a Trade UTICA BOILERS Trade n/a Model UBSSC-100 Cond n/a AHRI ref 5347439 Cal n/a AHRI ref n/a Efficiency 95 AFUE Efficiency n/a Heating input 100000 Btuh Sensible cooling 0 Btuh Heating output 91000 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 ROOM NAME Area Htg load Cig load Htg AVF CIg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) 1st. floor 992 16561 0 0 0 2nd. floor 698 12313 0 0 0 Entire House d 1691 28874 0 0 0 Other equip loads 0 0 Equip. @ 0.97 RSM 0 Latent cooling 0 TOTALS 1691 28874 0 1 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Aug-28 09 01 24 wrightSOft Right-Suite®universal 2015 15 0 19 RSU030D6 Page 1 /�. C 1UserslSam\DocumentstWnghtsoft WAClhobbs rup Cak:=MJ8 House faces N Loads for Multiple Orientations Job: +�+ wrightsoft, P Date: 08/29/2015 Entire House By: sam Andrews Oil and Gas Services Inc 136 rye street,south w ndsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scamprtelli@outlook com License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-4W7459 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature('F) 70 75 Elevation: 180 ft Design TD ('F) 62 17 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 26.2 27.4 Dry bulb (°F) 8 92 Infiltration: Daily range(°F) - 21 ( M ) Wet bulb ('F) - 73 Wind speed(mph) 15.0 7.5 House North Northeast East Southeast South Southwest West Northwest Sensible Load(Btuh) 0 0 0 0 0 0 0 0 Latent Load(Btuh) 0 0 0 0 0 0 0 0 Total Load (Btuh) 0 0 0 0 0 0 0 0 Heating AVF (cfm) 0 0 0 0 0 0 0 0 Cooling AVF (cfm) 0 0 0 0 0 0 0 0 Building Orientation Cooling Load 1.0 L 0.8 m M 0 0.6 _I m C_ O 0 0.4 m 0 H 0.2 0.0 N NE E SE S SW W NW Direction House faces Current Orientation: House faces North Highest Cooling Load: House faces North Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WCI htsOfit 2015-Aug-28 09 01 24 c 9 Right-Suite®universal 2015 15 0 19 RSW3006 Page 1 /�. C\Users\Sam\Documents\WnghtsoR HVAC\hobbs rup Calc=MJ8 louse faces N Building Analysis Job: +�+ wrightsoft 9 Date: 08/29/2015 Entire House By: sam Andrews Oil and Gas Services Inc 136 rye street,south wndsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scamptell@outloolt,=n License:3W782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 D- • Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature ff) 70 75 Elevation: 180 ft Design TD ff) 62 17 Latitude: 42'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/ib) 26.2 27.4 Dry bulb ff) 8 92 Infiltration: Daily range(°F) - 21 ( M ) Method Simplified Wet bulb ff) - 73 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Heatin Component Btuh/ft2 Btuh %of load Walls 5.2 8409 29.1 Glazing 32.9 7065 24.5 _. Doors 27.0 1458 5.1 Ceilings 2.0 1683 5.8 Floors 1.5 1268 4.4 Infiltration 5.0 8991 31.1 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Ad' stments 0 Total 28874 100.0 • • • Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 0 0 Latent Cooling Load= 0 Btuh Overall U-value = 0.171 Btuh/ft2-OF Data entries checked. wr ht%soft' 2015-Aug-28 09 01 25 Right-Suite®Unnersal 2015 15.0 19 RSU03006 Page 1 C\Users\Sam\Documents\WnghtsoR HVAC\hobbs rup Calc=MJ8 House faces N Component Constructions Job: +�+ wrightsok p Date: 08/29/2015 Entire House By: sam Andrews Oil and Gas Services Inc 136 rye street,south wrndsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scamprtelh@outlook corn License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 Design Conditions Location: Indoor. Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(OF) 70 75 Elevation: 180 ft Design TD (°F) 62 17 Latitude: 420N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 26.2 27.4 Dry bulb (°F) 8 92 Infiltration: Daily range(°F) - 21 ( M ) Method Simplified Wet bulb(°F) - 73 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain IT, fthff-T W-T/Ekuh EMJhNF BWh t3tuhre Btuh Walls 12C-Osw. Frm wall,vnl ext, 1/2'wood shth,r-13 cav ins, 1/2'gypsum a 447 0.091 13.0 5.64 2523 0 0 board int fnsh,r-1 ext bd ins,2'x4'wood firm, W o.c.stud 12C-2sw: Frm wall,vnl ext, 1/2'wood shth,r-13 cav ins, 1/2"gypsum s 263 0.081 15.0 5.02 1320 0 0 board int fish,r-2 ext bd ins,2"x4"wood frm, 16"o.c.stud w 473 0.081 15.0 5.02 2375 0 0 n 353 0.081 15.0 5.02 1774 0 0 all 1089 0.081 15.0 5.02 5469 0 0 Partitions 12C-2sw: Frm wall,eifs ext, 1/2"wood shth,r-13 cav ins, 1/7' 83 0.081 15.0 5.02 417 0 0 gypsum board int fnsh,r-2 ext bd ins,2"x4"wood frm, 16"o.c.stud Windows 4A5-2ov:2 glazing,clr low-e outr,air gas,insulated vinyl frm mat,clr a 85 0.470 0 29.1 2474 0 0 innr,1/4"gap,1/8"thk;50%drapes,medium,50%outdoor insect screen;foreground=green grass(0.23),6.67 It head ht 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,cir innr, 1/4"gap, s 29 0.570 0 35.3 1028 0 0 1/T thk;50%drapes,medium,50%outdoor insect screen, w 62 0.570 0 35.3 2191 0 0 foreground=green grass(0.23),6.67 It head ht n 39 0.570 0 35.3 1371 0 0 all 130 0.570 0 35.3 4591 0 0 Doors 1110:Door,wd pnl type,trill strm a 20 0,360 1.0 22.3 446 0 0 IN 17 0.360 1.0 22.3 379 0 0 all 37 0,360 1.0 22.3 826 0 0 11 JO Door,mtl fbrgl type n 17 0,600 6.3 37.2 632 0 0 Ceilings 166-30ad:Attic ceding,asphalt shingles roof mat,r-31 roof ins,r-30 848 0.032 30.0 1.98 1683 0 0 cell ins,1 Z gypsum board int fnsh 2015-Aug-28 09 01 25 �^.�� wrightsoft Right-SuRe®universal 2015 15.0 19 RSW3006 Page 1 Rlil� C\users\Sam\Documents\VVnghtsoR HVAC\hobos rup Calc=MJ8 House faces N Floors 19C-0bscp:Fir floor,frm fir,10"thlms,carpet fir frtsh,tight bsmt ovr, 842 0.368 11.0 1.51 1268 0 0 r-11 wad insul 2015-Aug-28 09 01:25 !�C wrightSoft' RightSurte®Universal 2015 15 0 19 RSU03006 Page 2 04t..(.f�C.\Usem%Sam\Documents\WrightsoR HVAC\hobbs.rup Cale=MJ8 House faces: N Component Constructions Job: +�- wrightsoft Date: 08/29/2015 1st, floor By: sam Andrews Oil and Gas Services Inc 136 rye street,south windsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scampdeM@outlock corn License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(T) 70 75 Elevation: 180 ft Design TD (T) 62 17 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 26.2 27.4 Dry bulb(T) 8 92 Infiltration: Daily range(T) - 21 ( M ) Method Simplified Wet bulb( F) - 73 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft, BtuhM'-F ft'-F/Btuh Btuhff BNh BtuhMV Btu Walls 12C-Osw:Frm wall,vnI ext, 1/T wood shth,r-13 cav ins,1/T gypsum a 246 0.091 13.0 5.64 1388 0 0 board int fish,r-1 ext bd ins,Tx4'wood frm,16'o.c.stud 12C-2sw: Frm wa g,ml ext,1/2'wood shth,r-13 cav ins,1/2'gypsum s 86 0.081 15.0 5.02 433 0 0 board int fresh,r-2 ext bd ins,2 x4'wood frm,16"o.c.stud w 260 0.081 15.0 5.02 1306 0 0 n 177 0.081 15.0 5.02 887 0 0 all 523 0.081 15.0 5.02 2626 0 0 Partitions 12C-2sw: Firm wag,eifs ext, 1/T wood shth,r-13 cav ins, 1/2' 83 0.081 15.0 5.02 417 0 0 gypsum board int fnsh,r-2 ext bd ins,ZW4'wood frm, 16'o.c.stud Windows 4A5-2ov:2 glazing,cir low-e outr,air gas,insulated vinyl frm mat,clr a 58 0.470 0 29.1 1690 0 0 nnr,1/4"gap, 1/8"thk;50%drapes,medium;50%outdoor insect screen,foreground=green grass(0.23),6.67 ft head ht 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, s 10 0.570 0 35.3 343 0 0 1/8"thk,50%drapes,medium;50%outdoor insect screen; w 47 0.570 0 35.3 1661 0 0 foreground=green grass(0.23),6.67 ft head ht n 19 0.570 0 35.3 686 0 0 all 76 0.570 0 35.3 2689 0 0 Doors 1110:Door,wd pnl type,mtl strm a 20 0.360 1.0 22.3 446 0 0 w 17 0.360 1.0 22.3 379 0 0 all 37 0,360 1.0 22.3 826 0 0 11 J0: Door,mtl fbrgl type n 17 0.600 6.3 37.2 632 0 0 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 150 0.032 30.0 1.98 298 0 0 ceil ins, 1/T gypsum board int fnsh 2015-Aug-28 09 01 25 •�- wrighttsoft` Right-Suite®universal 2015 15 0 19 RSU03006 Page 3 C\Users\Sam\Documents\vvnghtsotl M/AC\hobbs rup Cale=MJ8 House faces N it Floors 19C-Obscp:Fir floor,frrn fir,10"thlms,carpet fir fnsh,tight bsrnt ovr, 842 0.368 11.0 1.51 1268 0 0 r-11 wall insul ' wrightSOft• Rrghtsurte®Unroersal 2015 15A 19 RSLM008 2015 Aug 28 09 ag1 4 /tC�C:\UserstSarrrlDocuments\Wrightsolt HVAC\hobbs.rup Cao=MJ8 house faces: N Component Constructions Job: wrighttsoft° P Date: 09*91201 i 2nd. floor By: sam Andrews Oil and Gas Services Inc 136 rye street,south wmdsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scampitelli@outlook com License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(°F) 70 75 Elevation: 180 ft Design TD (°F) 62 17 Latitude: 420N Relative humidity(%) 30 50 Outdoor. Heating Cooling Moisture difference(gr/lb) 26.2 27.4 Dry bulb(T) 8 92 Infiltration: Daily range ff) - 21 ( M ) Method Simplified Wet bulb(- ) - 73 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain lF BWh4F--°F re-Tfiltuh BWhNF Stuh 811.111iR' BDUh Walls 12C-0sw:Frm wal,vnl ext,1/2"wood shth,r-13 cav ins,1/2"gypsum a 201 0.091 13.0 5.64 1135 0 0 board int fish,r-1 ext bd ins,2"x4 wood frm,16"o.c.stud 12C-2sw:Frm wal,vni vd, 112"wood shth,r-13 cav ins,1/2"gypsum s 177 0.081 15.0 5.02 887 0 0 board int fresh,r-2 ext bd ins,2"x4"wood firm,16"o.c.stud w 213 0.081 150 5.02 1070 0 0 n 177 0.081 15.0 5.02 887 0 0 al 566 0.081 15.0 5.02 2843 0 0 Partitions (none) Windows 4A5-2ov:2 glazing,cir Toler-e outr,air gas,insulated vinyl frm mat,ck a 27 0.470 0 29.1 784 0 0 nnr,1/4"gap,1/8"thK 50%drapes,medium;50%outdoor insect screen;foreground=green grass(0.23);6.67 ft head ht 1 D-c2ov:2 ghwing,clr outr,air gas,vnl frm mat,ck nnr,1/4"gap, s 19 0.570 0 35.3 686 0 0 11W thK 50%drapes,medium;50%outdoor insect screen; w 15 0.570 0 35.3 530 0 0 foreground=green grass(0.23);6.67 ft head ht n 19 0.570 0 35.3 686 0 0 al 54 0.570 0 35.3 1901 0 0 Doors (none) Ceilings 168-30ad:Attic ceing,asphalt shingles roof mat,r-31 roof ins,r-30 698 0.032 30.0 1.98 1385 0 0 cel ins,1/2"gypsum board int fnsh Floors (none) .01 wrightsoft' Right-Suite®Unnersal 2015 15.0.19 RSU03006 2015 Aug-28 09 Page 5 25 /�M C\Users\Sam\Documents\WnghtsoR WAC\hobbs.rup Calc=MJ8 House Faces. N Project Summary Job: wrightsoft, J Date: 08129/2015 Entire House By: sam Andrews Oil and Gas Services Inc 136 rye street,south vandsor,ct 06074 Phone 8605280766 Fax 8605286695 Email scampdelh@outlook corn License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 Notes: Design Information Weather: Windsor Locks Bradley Field, CT, US Winter Design Conditions Summer Design Conditions Outside db 8 'F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 62 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28874 Btuh Structure 0 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28874 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 0 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 0 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 1691 0 Equipment latent load 0 Btuh Volume(ft') 13524 0 Air changes/hour 0.59 0.41 Equipment total load 0 Btuh Equiv.AVF (cfm) 133 0 Req. total capacity at 0.70 SHR 0 ton Heating Equipment Summary Cooling Equipment Summary Make ECR INTERNATIONAL Make n/a Trade UTICA BOILERS Trade n/a Model UBSSC-100 Cond n/a AHRI ref 5347439 Coil n/a AHRI ref n/a Efficiency 95 AFUE Efficiency n/a Heating input 100000 Btuh Sensible cooling 0 Btuh Heating output 91000 Btuh Latent coding 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2015-Aug-28 09 01 25 t wrightS0f Right-Suite®Universal 2015 15 0 19 RSU03006 Page C C\Users\Sam\Documents\wrightsoft HVAC\hobos rup Calc=MJ8 House faces N AED Assessment Job: -�"f'f' wrightsoft- Date: 08/29/2015 Entire House By: sam Andrews Oil and Gas Services Inc 136 rye street, south windsor, ct 06074 Phone 8605280766 Fax 8605286695 Email.scampltelli@outlook corn License 303782 Project • • For: Curtis& Brooke Hobbs 169 Maskel Road, South Windsor, ct 06074 Phone: 860-490-7459 Design Conditions Location: Indoor: Heating Cooling Windsor Locks Bradley Field, CT, US Indoor temperature(OF) 70 75 Elevation: 180 ft Design TD (OF) 62 17 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grtlb) 26.2 27.4 Dry bulb(OF) 8 92 Infiltration: Daily range (°F) - 21 ( M ) Wet bulb (OF) - 73 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Hourly Glazing Load 1,000 900 800 700 m 600 0 m 400 300 200 100 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Maximum hourly glazing load exceeds average by 0.0%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh wri htsoft' 2015-Aug-28 09 01 25 !L 9 Right-Suite®Universal 2015 15 0 19 RSU03006 Page 1 /IC.C� C\Users\Sam\Documents\Wnghtsoft HVAC\hobos rup Calc=MJ8 House faces N wrightsoftr Right-M)Worksheet Job: Entire House Date: 08129/2015 Andrews Oil and Gas Services Inc By, sarrt 136 rye street,south Windsor,ct 06074 Phone:8605280766 Fax:8605286695 Email:scamptellNLboutlo*.con License:303782 1 Room name Ernie Horse 1st.floor 2 EiWed wag 236.0 ft 130.0 ft 3 Room height 8.0 ft d 8.0 ft heat only 4 Room dimensions 40.5 x 24.5 ft 5 Room area 1690.5 ft' 992-3 ft' Ty Construction U-value Or HTM Area gt2) load Area (111) Load number (BtuhM2_*F) (BtWft2) or perimeter (ft) (Btuh) or poineter (11) (Btuh) Heat Cool Gross NIPIS Het Cod Gross N/PIS Heat Cod 6 V)I 12C-0sw 0.091 a 5.64 0.00 552 447 2523 0 324 246 1388 0 ;l_GO 4A5-2w 0.470 a 29.14 0.00 85 0 2474 0 58 0 1690 0 lie 0.360 a 22.32 0.00 20 20 446 0 20 20 446 0 1t 12C-2sw 0.081 s 5.02 0.00 292 263 1320 0 96 86 433 0 11 G, 1D-c2w 0.570 s 35.34 0.00 29 0 1028 0 10 0 343 0 12C-2sw 0.081 w 5.02 0.00 552 473 2375 0 324 260 1306 0 1Dc2m 0.5m w 35.34 O.OD 62 0 2191 0 47 0 1661 0 111) 0.360 w 22.32 0.00 17 17 379 0 17 17 379 0 tWI 12G2sw 0.081 n 5.02 0.OD 392 353 1774 0 196 177 887 0 G 1Dc2w 0.570 n 35.34 0.00 39 0 1371 0 19 0 686 0 q 12C-2sw 0.081 - 5.02 0.00 100 83 417 0 100 83 417 0 g-D 11J0 0.600 n 37.20 0.00 17 17 632 0 17 17 632 0 C 16B30ad 0.032 - 1.98 0.00 848 848 1683 0 150 150 298 0 F 19C-Obscp 0.368 - 1.51 0.00 842 842 1268 0 842 842 1268 0 6 c)AED excursion 0 0 Envelope loss/gain 19882 0 11834 0 12 a) Infiltration 8991 0 4727 0 b) Room ventUion 0 0 0 0 13 Internal gains: Oo tVarts 230 8 0 4 0 Appianceslother 0 0 Subtotal(lines 6 to 13) 28874 0 1 16561 0 Less eodernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28874 0 16561 0 15 Dud loads 0% 0% 0 0 4)% 0% 0 0 Total room load 28874 0 16WI 1 0 Air required(dm) 0 01 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' wrightsoft- 2015-Aug-28 09 01:25 RightSuite®Universal 2015 15.Q 19 RSU03006 Page 1 I&K C:%Users%Sam\Documents\Wrightsoft WAC\hobbs.rup Calc=MJ8 House faces: N wrightsoft• Right-M Worksheet Job: Entire House Date: 0=912015 By: sam Andrews Oil and Gas Services Inc 136 rye street,south vdndsor,ct 06074 Phone:8605280766 Fax:8605286695 Email:scampitelli(goutlodc.com License:303782 1 Room name 2nd.floor 2 Exposed wall 106.0 ft 3 Room height 8.0 ft beat only 4 Room dxnensions 24.5 x 28.5 ft 5 Room area 698.3 ft= Ty Constriction u-ralue Or HTM Area (1111) Load Area Load number (Btutdftk*F) (Btuh/fl') or pernneler (ft) (Bluh) or perirraer Heat Cod Gross N/P/S Heat Cod Gross WP/S Had Cod 6 12C-0sw 0.091 a 5.64 0.00 228 201 1135 0 4AS2or 0.470 a 29.14 0.00 27 0 784 0 Ilia 0.360 a 22.32 0.00 0 0 0 0 12C-2sw 0.081 s 5.02 0.00 196 177 887 0 11 II}c2ov 0.5m s 35.34 0.00 19 0 686 0 V)I 12C-2sw 0.081 w 5.02 0.00 228 213 1070 0 IL--G� ID-c2ov 0.570 w 35.34 0.00 15 0 530 0 1110 0.360 w 22.32 0.00 0 0 0 0 V+l 12C-2sw 0.081 n 5.02 0.00 196 177 887 0 �--G 1Dc2or 0.570 n 35.34 0.00 19 0 686 0 q 12C-2sw 0.081 - 5.02 0.00 0 0 0 0 t-O 1111.10 0.600 n 37.20 0.00 0 0 0 0 C 16830ad 0.032 - 1.98 0.00 698 698 1385 0 F 19C4bscp 0.368 - 1.51 0.00 0 0 0 0 6 c)AED excursion 0 Er-lope loss/gain 8049 0 12 a) Infiltration 4264 0 b) Room ventilation 0 0 13 Internal gains: Occupants 230 4 0 Appliances/other 0 Subtotal(f m 6 to 13) 12313 0 Less eDdemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 12313 0 15 Duct bads 096 0% 0 0 Trial room load 12313 0 Air required(cfm) 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsofC Right-Suited!)universal 2075 15 0.19 RSU03006 2015 Aug-28 09.01:25 C:\UserslSam\Documents%Wrightsdt HVAC%hobbs nip Calc=MJ8 House faces: N Page 2 1500361 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 09/11/2015 GIS ID: 57900169 FEE: 150.00 MUNIS APPLICATION# 201501208 BUILDING DESCRIPTION: APPLICANTy., •-. r LOCATION NAME: ANDREWS OIL CO. <<`` ADDRESS: 169 MASKEL ROAD ADDRESS: 136 RYE STREET :^' OWNER: HOBBS KURTIS { P. 169 MASKEL ROAD SOUTH WINDSOR,CT 06074 , �.+ ,-SOUTH WINDSOR,CT 06074 ;a r Gwq� DESCRIPTION OF WORK: RUNNING HOUSE GAS MAIN,INSTALLING NEW GAS BOILER,AND INDIRE&.HOT.WATER HEATER. SPECIAL CONDITIONS: ; ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS,APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 9/11/2015 2:56 PM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE 1300069 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER ELECTRICAL PERMIT DATE: 02/20/2013 GIS ID: 57900169 FEE: 30.00 MUNIS APPLICATION# 201300160 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: SHEA DAVID ADDRESS: 169 MASKEL ROAD ADDRESS: 385 NIEDERWEIFER ROAD OWNER: TRIPP LESLIE J SOUTH WINDSOR,CT 06074 r ^- 432 BUCKLAND RD RM 106 SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: 100 AMP SERVICE CHANGE. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 2/20/2013 10:41 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE