Loading...
HomeMy WebLinkAbout165 HOMESTEAD DR APPLICATION FOR HVAC PERMIT DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT# Applic is b�reb : BUILDING DEPARTMENT P 5 0�g' 1540 SULLIVAN AVENUE i 644-2511 ext. 230 Bldg.Permit# Date 'lding Inspector Application must be printed or typed FEE SCHEDULE '' �II Location ofJ_oIb: $041,000=$15.00 W 5 t cyne.3 'ec� d.T� -p— Over$1,000= Street No. Street Lot No. $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Le nn U S ka i•t1' APPLICANT ADDRESS PQ &)k SO2-1 LBEr li n. CT' 0(0037 APPLICANT''S PHONi# ' 60- &6U" 00 I Z OWNER C.h A O L c re-1 h a 00 OMI N St 4 OWNER ADDRESS OWNER PHONE 3(Qd Z V q -- 50 3 N ESTIMATED COST$ _ D C( ..� V IS THIS A CONTRACT COST? &Yes No FEE ENCLOSED$ (00 TYPE OF JOB: �2'q�� (Q �SOR.COS New Installations Alteration/Addition/Repair a01,5D1-144 Revised 03/05/10 APPLICATION FOR HVAC PERNUT(Continued from teyerse side) TYPE OF SYSTEM: TYPE OF B��ING: SEATING PRESIDENTIAL C ❑ COMMERCIAL ❑ VENTILATION ❑ INDUSTRIAL HEATING (3 STEAM LOW PRESSURE LB41T LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC P-WARM AIR ❑ UNIT RADIANT.HEAMR EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP.OUTSIDE ��� °F INSIDE�_OF DIFFERENCE '9- °F TOTAL HEAT LOSS(BTUH)6�=a.�°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) —j, It Q DESCRIBE,ALL H`EATING EQUIPMENT(INCLUDINGMAKE&MODEL NO.) p f GROSS HEATING CAPACITY f INPU -BTUH)_ NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION:❑ INSIDE ❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP: OUTSIDE Uu OF INSIDE °F DIFFERENCE,w OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION DESCRIBE C LING EQUIPMENT MCLUDING MAKE&MODEL NO. TONNAGE � COOLING CAPACITY(BTUH)00 0-6� VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) _ FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. �96a7�6 .3y33-:)& - CONTRACTORS LICENSE NO. TYPE ST SIGNATURE OF APPLICANT DATE • A First Response HVAC P.O.Box 8027 Berlin,CT 06037 390236&393320 Heat Load Summary Report for Chreiha ,Chadi Room Square Heating Loss Hydronic Heat Latent / Sensible Cooling Gain Cooling Cooling Name Ft. BTUH Linear Ft. Gain BTUH BTUH Tons CFM Bedroom#4 first floor 240 4518 7.53 415 /2111 2526 0.21 84 Laundry Room 117 7264 12.11 1375 /3378 4753 0.4 158 Mud Room 32 1212 2.02 229 /1021 1250 0.1 42 Formal Dining Room 186 3654 6.09 566 /2155 2721 0.23 91 Formal Living Room 300 8926 14.88 702 /5333 6035 0.5 201 Entrance Foyer 88.4 6693 11.15 949 /3009 3959 0.33 132 1 st floor 1/2 bath 18 201 0.34 227 /967 1194 0.1 40 Kitchen 234 4418 7.36 1009 /4775 5785 0.48 193 Dinette 120 3810 6.35 507 /2338 2845 0.24 95 Great Room 360 9418 15.7 803 /9490 10293 0.86 343 Bedroom#1 204 3976 6.63 383 /2508 2891 0.24 96 2nd Floor Full Bath 50 1283 2.14 245 /1520 1764 0.15 59 Bedroom#2 182 4756 7.93 363 14193 4556 0.38 152 Bedroom#3 165 3114 5.19 348 /2106 2454 0.2 82 Master Bedroom 270 6157 10.26 642 /4045 4687 0.39 156 Master Bath 63 2003 3.34 456 /3123 3579 0.3 119 TOTALS 2629 71403 119.01 9219 / 52072 61293 5.11 2043 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total BTUs. Prepared 11/12/2015 using O'Brien Quick Loads Pro-Version 1.01 -SN:OP-070101-41346 I GARDNER PETERSON ASSOCIA71:y 575 OLD Posr nvAD TOLLAND, CONNECTICUI 06Ud0 y2 4i IY1 N N ni s 3g •S 391.(� N 37 ae .s bsz•1 381.3 O ^ 3es.o v o~ L- 4k. cL5'± TWISZ17 t"aWrWAY .? 0o 3b bey.q ' �y ^�• 39� 382.1 3-TB V 361.8 281.5 ale 50' a b 0 iso.00' 370• 1 1-I C>M E S'T'EAO MORTGAGE SURVEY LOT #36 TIMBER RIDGE SECTION IV TOWN OF SOUTH WINDSOR, CONNECTICUT SCALE: 1" = 40' I hereby certify to Connecticut Attorney's Title Guaranty Fund, Inc. and The Savings Bank of Rockville that the location of the building as shown is substantially correct and that there are no zoning violations of the same. L.S. #10839 _ -- June 2, 1981 PROFESSIONAL ENGINEERS LAND SURVEYORS �Zq'i-3c. A P � RIOVED TOWN OF NDSOR DATE:--6-p.nd y''8/ SIG.: �e GARDNER Et PETERSON ASSOCIATES 576 OLD POST ROAD TOLLAa1NOD, C0�ECT/CUT 06084 n "A co 3aa 0 N v) \ 388 3R~ 49'- �1 N 0Tr_ 3Yro.o ry —�— '-�� B 8.4 Z• 24-.2 \ \2 5'* %s-4' �� \ ?6 c '-B4 \IN \ \ nz 374 S-7 3 80 3c L O :sill" PERMIT PLAN LAND OF U. & R. HOUSING CORP. LOT #36 TIMBER RIDGE SEC. IV. ,04,�r�e� .AeIF� TOWN OF SOUTH WINDSOR, CONNECTICUT SCALE: 1" = 40' Certified substantial) corrects No. ioass rsr.eaE° / 1 � '�''�o r U Rv {Dy1s9 L.S. 10839 4�uuia�visn January 23, 1981 Elev. base, M.D.C. Datum �� PROFESSIONAL ENGINEERS LAND SURVEYORS f /6 5 GARDNER Et PETERSON ASSOCIATES 576 OLD POST ROAD TOLLAND, CONNECTICUT 06084 - 510 Sad ' N V1 " INN 0 Twe 3S�,a � r 4 24 �-► 374 _- -- _ 44 3So H s'3°-30�-oo•'vvC O ` PERMIT PLAN LAND OF U. & R. HOUSING CORP, oR. f , LOT #36 TIMBER RIDGE SEC. IV. TOWN OF SOUTH WINDSOR, CONNECTICUT �, .: SCALE• 1" = 40' :"�" � �` '4 No. 10339 Certified substantial l correct toy, ti� U RV R Div C..�„1 `QOtL.dlTff3J� v - J L.S. 10839 January 23, 1981 Elev. base, M.D.C. Datum PROFESSIONAL ENGINEERS LAND SURVEYORS �� c - ' AP R 0 Y E D TOWN OF SOUTH WINDSOR ENGINEERING DEPARTMENT DATE: 1, Z'�V - �SIG.:_z �✓jICG�-�l�r� 1500535 TOWN OF SOUTH WINDSOR, CT PERMIT NUMBER HVAC PERMIT DATE: 12/15/2015 GIS ID:44700165 FEE: 75.00 MUNIS APPLICATION# 201501766 BUILDING DESCRIPTION: APPLICANT LOCATION NAME: FIRST RESPONSE ADDRESS: 165 HOMESTEAD DRIVE ADDRESS: P.O.BOX 8027 OWNER: NEUHAUS ELLEN G BERLIN,CT 06037 165 HOMESTEAD DRIVE SOUTH WINDSOR,CT 06074 DESCRIPTION OF WORK: REPLACE HEAT PUMP CONDENSER AND AIR HANDLER. SPECIAL CONDITIONS: ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT. CONSTRUCTION TYPE: OCCUPANCY GROUP: BUILDING OFFICIAL 12/15/2015 9:43 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE