HomeMy WebLinkAbout165 HOMESTEAD DR APPLICATION FOR HVAC PERMIT
DEPARTMENT DECISION TOWN OF SOUTH WINDSOR PERMIT#
Applic is b�reb : BUILDING DEPARTMENT
P 5 0�g'
1540 SULLIVAN AVENUE i
644-2511 ext. 230
Bldg.Permit#
Date 'lding Inspector
Application must be printed or typed
FEE SCHEDULE '' �II Location ofJ_oIb:
$041,000=$15.00 W 5 t cyne.3 'ec� d.T� -p—
Over$1,000= Street No. Street Lot No.
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT Le nn U S ka i•t1'
APPLICANT ADDRESS PQ &)k SO2-1
LBEr li n. CT' 0(0037
APPLICANT''S PHONi# ' 60- &6U" 00 I Z
OWNER C.h A O L c re-1 h a
00 OMI N St
4 OWNER ADDRESS
OWNER PHONE 3(Qd Z V q -- 50 3 N
ESTIMATED COST$ _ D C(
..� V IS THIS A CONTRACT COST? &Yes No
FEE ENCLOSED$ (00
TYPE OF JOB: �2'q�� (Q
�SOR.COS New Installations
Alteration/Addition/Repair
a01,5D1-144
Revised 03/05/10
APPLICATION FOR HVAC PERNUT(Continued from teyerse side)
TYPE OF SYSTEM: TYPE OF B��ING:
SEATING PRESIDENTIAL
C ❑ COMMERCIAL
❑ VENTILATION ❑ INDUSTRIAL
HEATING
(3 STEAM LOW PRESSURE LB41T LBS. HIGH PRESSURE LIMIT LBS.
❑ HYDRONIC P-WARM AIR ❑ UNIT RADIANT.HEAMR
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP.OUTSIDE ��� °F INSIDE�_OF DIFFERENCE '9- °F
TOTAL HEAT LOSS(BTUH)6�=a.�°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
—j, It
Q DESCRIBE,ALL H`EATING EQUIPMENT(INCLUDINGMAKE&MODEL NO.)
p f
GROSS HEATING CAPACITY f INPU -BTUH)_ NET RATING(OUTPUT BTUH)
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION:❑ INSIDE ❑ OUTSIDE CAPACITY
❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP: OUTSIDE Uu OF INSIDE °F DIFFERENCE,w OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION
DESCRIBE C LING EQUIPMENT MCLUDING MAKE&MODEL NO.
TONNAGE � COOLING CAPACITY(BTUH)00 0-6�
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION) _
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
�96a7�6 .3y33-:)& -
CONTRACTORS LICENSE NO. TYPE ST
SIGNATURE OF APPLICANT DATE
• A First Response HVAC
P.O.Box 8027 Berlin,CT 06037
390236&393320
Heat Load Summary Report for Chreiha ,Chadi
Room Square Heating Loss Hydronic Heat Latent / Sensible Cooling Gain Cooling Cooling
Name Ft. BTUH Linear Ft. Gain BTUH BTUH Tons CFM
Bedroom#4 first floor 240 4518 7.53 415 /2111 2526 0.21 84
Laundry Room 117 7264 12.11 1375 /3378 4753 0.4 158
Mud Room 32 1212 2.02 229 /1021 1250 0.1 42
Formal Dining Room 186 3654 6.09 566 /2155 2721 0.23 91
Formal Living Room 300 8926 14.88 702 /5333 6035 0.5 201
Entrance Foyer 88.4 6693 11.15 949 /3009 3959 0.33 132
1 st floor 1/2 bath 18 201 0.34 227 /967 1194 0.1 40
Kitchen 234 4418 7.36 1009 /4775 5785 0.48 193
Dinette 120 3810 6.35 507 /2338 2845 0.24 95
Great Room 360 9418 15.7 803 /9490 10293 0.86 343
Bedroom#1 204 3976 6.63 383 /2508 2891 0.24 96
2nd Floor Full Bath 50 1283 2.14 245 /1520 1764 0.15 59
Bedroom#2 182 4756 7.93 363 14193 4556 0.38 152
Bedroom#3 165 3114 5.19 348 /2106 2454 0.2 82
Master Bedroom 270 6157 10.26 642 /4045 4687 0.39 156
Master Bath 63 2003 3.34 456 /3123 3579 0.3 119
TOTALS 2629 71403 119.01 9219 / 52072 61293 5.11 2043
Disclaimer
These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a
professional installation.The installing contractor's experience and expert judgement are also major factors in sizing and installing a
complete system.The weather,customer usage,duct installation,and structure design may vary on each estimate and should be taken
into account.Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements,not just total
BTUs.
Prepared 11/12/2015 using O'Brien Quick Loads Pro-Version 1.01 -SN:OP-070101-41346
I
GARDNER PETERSON ASSOCIA71:y 575 OLD Posr nvAD TOLLAND, CONNECTICUI 06Ud0
y2
4i
IY1
N
N
ni
s
3g •S 391.(� N
37 ae .s bsz•1 381.3 O
^ 3es.o
v o~ L- 4k.
cL5'± TWISZ17 t"aWrWAY
.? 0o
3b bey.q
' �y ^�• 39� 382.1
3-TB V 361.8 281.5
ale 50'
a
b
0
iso.00' 370• 1
1-I C>M E S'T'EAO
MORTGAGE SURVEY
LOT #36 TIMBER RIDGE SECTION IV
TOWN OF SOUTH WINDSOR, CONNECTICUT
SCALE: 1" = 40'
I hereby certify to Connecticut Attorney's Title Guaranty Fund, Inc.
and The Savings Bank of Rockville that the location of the building
as shown is substantially correct and that there are no zoning
violations of the same.
L.S. #10839 _ --
June 2, 1981
PROFESSIONAL ENGINEERS LAND SURVEYORS
�Zq'i-3c.
A P � RIOVED
TOWN OF NDSOR
DATE:--6-p.nd y''8/
SIG.: �e
GARDNER Et PETERSON ASSOCIATES 576 OLD POST ROAD TOLLAa1NOD, C0�ECT/CUT 06084
n "A
co
3aa
0
N
v)
\ 388
3R~
49'-
�1 N 0Tr_ 3Yro.o ry —�—
'-��
B 8.4 Z• 24-.2 \
\2 5'* %s-4' �� \ ?6 c
'-B4
\IN \ \ nz
374
S-7
3 80
3c L
O
:sill"
PERMIT PLAN
LAND OF U. & R. HOUSING CORP.
LOT #36 TIMBER RIDGE SEC. IV. ,04,�r�e� .AeIF�
TOWN OF SOUTH WINDSOR, CONNECTICUT
SCALE: 1" = 40'
Certified substantial) corrects No. ioass
rsr.eaE°
/ 1 � '�''�o r
U Rv {Dy1s9
L.S. 10839 4�uuia�visn
January 23, 1981
Elev. base, M.D.C. Datum ��
PROFESSIONAL ENGINEERS LAND SURVEYORS f
/6 5
GARDNER Et PETERSON ASSOCIATES 576 OLD POST ROAD TOLLAND, CONNECTICUT 06084
- 510
Sad
' N
V1
" INN
0 Twe 3S�,a �
r
4 24
�-► 374
_- -- _ 44 3So
H s'3°-30�-oo•'vvC
O
`
PERMIT PLAN
LAND OF U. & R. HOUSING CORP, oR. f ,
LOT #36 TIMBER RIDGE SEC. IV.
TOWN OF SOUTH WINDSOR, CONNECTICUT �, .:
SCALE• 1" = 40' :"�" � �` '4
No. 10339
Certified substantial l correct
toy, ti� U RV R Div
C..�„1 `QOtL.dlTff3J�
v - J L.S. 10839
January 23, 1981
Elev. base, M.D.C. Datum
PROFESSIONAL ENGINEERS LAND SURVEYORS ��
c
- ' AP R 0 Y E D
TOWN OF SOUTH WINDSOR
ENGINEERING DEPARTMENT
DATE: 1, Z'�V -
�SIG.:_z �✓jICG�-�l�r�
1500535 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 12/15/2015
GIS ID:44700165 FEE: 75.00
MUNIS APPLICATION# 201501766 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: FIRST RESPONSE ADDRESS: 165 HOMESTEAD DRIVE
ADDRESS: P.O.BOX 8027 OWNER: NEUHAUS ELLEN G
BERLIN,CT 06037 165 HOMESTEAD DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: REPLACE HEAT PUMP CONDENSER AND AIR HANDLER.
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
12/15/2015 9:43 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE