HomeMy WebLinkAbout164 HILTON DR ae*
go
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
APPTJ__� 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230
Date BuilcLng Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job: -
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT j4j-r,f`0
PLICANppT ADDRESS _
Nt 5 S // O
APPLICANT PH #
W N S OWNER Q, C. -
O �q< OWNER ADDRESS LLe1w I
OOWNER PHONE
C +' ESTIMATED COST$ O D- O O
•-�i U
IS THIS A CONTRACT C�OSTT?- Yes _No
FEE ENCLOSED$
���- ���� TYPE OF JOB:
R ih
Zw Installation
l�teration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR AVAC PERNUT (Continued from reverse side)
TYPE OF YSTEM: TYPE F DING:
TING M�IDENTIAL
A/C ❑COMMERCIAL
❑VENTII.ATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT' LBS.
O HYDRONIC 0 WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE a DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) T(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE A14,HEA Gga Lwlm-p 0 (a AS 2f (INC UD G MAKE&O�IODEL NO)
U
c A/
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
❑OIL--GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY
O GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMP APPLICATION) /
FURTHER DESCRIPTION OF WORK /!1 SA&IL P�
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
303Q3 a �J/ (27r
CONTRACTORS LICENSE TYPE STATE
SIGNATURE OF APPLIC 4,W - DATE 9 //,5110
AFELL6 CORPORATE OFFICE P.O. BOX 548,WINDSOR LOCKS, CT 06096
nia Plumbing • Heating • Electrical •Air Conditioning •Water Quality Solutions
HOME SERVICES
To Whom This May Concern:
Aiello Home Services authorized Linda Dawson-Hayes, Russell Horrocks, Stephen
Birch, Garrett Cardwell, Tim Lynch, Joe Sparveri, Keith Tyler,Randy Weidig,
Scott White, Robert Bilodeau, Mark Putorti, Melissa Mariani, to pull permits for our
company for any plumbing,heating or air conditioning replacement(s)or new
installation(s). If you have any questions please call our office at 860-292-2600.
This letter is for a permit for the property located at:
A4 14,OyK� _J)kiu9 4, �A WwLg , ('�_T` ia o q4(-
Homeowner: �kel ",SM1&LL125
Permit Fee Amount: $ x
Sincerely,
Michael Jezouit
President
STATE OF CONNECTICUT STATE OF CONNECTICUT
DEPARTMENT OF CONSUMER PROTFCTION DEPARTMENT OF COIVSUMER PROTECTION
HEATING,PIPING&CO.0j EMI TED CONTRACT LIMITED SHED' , :C�9dV TRACTOR
E•. +,. —
MICR JF�iT MI
R JT
096
WIND #096 WIND
REG N I LIC.I REG NGT IVi 1 IRE
rS, 31/2011 $HM.0005345- a a /31/2011
HTG.0303032 l ;►_, c
�rR`ANST(it/
SIGNED SIGNED----��--'_
Local 860-292-2600 • Connecticut Toll Free 1-888-956-4455 Fax 860-292-2690
Connecticut License Numbers • P1-203350 • S1-303032 • E1-0196723 • Aiello is an AA/EOE 07110
f?hvac-Residential&Light Commercial HVAC Loads Elite Software Development,
Aiello Home Services Boiler Replacement
Windsor Locks,CT 06096 Page 2,
Project Report
General Project Information
Project Title: Boiler Replacement
Designed By: Joe Sparveri
Project Date: 9/14/10
Client Name: Smeallic Home
Client Address: 164 Hilton Drive
Client City: South Windsor Ct
Client Phone: 528-5057
Company Name: Aiello Home Services
Company Representative: Joe Sparveri
Company Address: 600 Old County Circle
Company City: Windsor Locks, CT 06096
Company Phone: (860)292-2635
Company Fax (860)292-2690
Company yC�omment: The right comfort for your home.
[De 8lgft Data s Y Pr ' a -.
Reference City: Hartford, Connecticut
Daily Temperature Range: Medium
Latitude: 41 Degrees
Elevation: 19 ft.
Altitude Factor: 0.999
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference
Winter: -5 0 45 70 46
�Summer: 95 73 50 72 28
Check. '' r> a t 6 >K L x 2 rg
i
Total Building Supply CFM: 1,065 CFM Per Square ft.: 1.082
Square ft. of Room Area: 984 Square ft. Per Ton: 427
Volume(W)of Cond. Space: 7,872 Air Turnover Rate (per hour): 8.1
Building Loads
Total Heating Required With Outside Air: 56,860 Btuh 56.860 MBH
Total Sensible Gain: 19,903 Btuh 93 %
Total Latent Gain: 1,428 Btuh 7 %
Total Cooling Required With Outside Air: 21,331 Btuh 2.30 Tons (Based On 72% Sensible Capacity)
KAO*
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Program Files\Elite\Rhvacw\Projects\Boman small ranch.rhv Tuesday, September 14, 2010, 5:50 PM
►Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Aiello Home Services Boiler Replacement
Windsor Locks,CT 06096 13 e 4
Load Preview Report
Has Net Rec ft.2 Sen Lat Net Sen Hts C� Apt Duct
Scope AED Ton Ton lion Area Gain Gain Gain Loss g Size
CFM CFM CFM
Building 1.78 2.30 427 984 19,903 1,428 21,331 56,860 487 1,065 1,065
System 1 No 1.78 2.30 427 984 19,903 1,428 21,331 56,860 487 1,065 1,065 20x10
Duct Latent 923 923
Hurricification 2,166
Zone 1 984 19,903 505 20,408 54,694 487 1,065 1.065 20x10
1-Block Load 984 19,903 505 20,408 54,694 487 1,065 1,065 10-6
C:\Program Files\Elite\Rhvacw\Projects\Boman small ranch.rhv Tuesday, September 14, 2010, 5:50 PM
Revised 4/01H2002
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby:
BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE
Bldg.Permit#
644-2511 ext. 230
Date Bu• AAW
Application must be printed or typed
FEE SCHEDULE Location of Job:
$0-$1,000=$15.00 FT-enantDesignation
Street ]No.Over$1,000=
$15.00 per$1,000
or any fraction thereof Apt.No.
APPLICANT
APPLICANT ADDRESS ( �-a!/L✓rIQ Y skb�2
APPLICANT PHONE# �y 2-9 6 �,S- 76
O W N )S f OWNER ;,.. ti <
p, 1 Sy,Yj ctil)I t
q OWNER ADDRESS 0f
Ow r OWNER PHONE .}2 5-6 S -')
C ESTIMATED COST$ I �a
IS THIS A CONTRACT COST? Yes _No _
'k �(� FEE ENCLOSED$
r/y TYPE OF JOB:
dSOR-Cps _New Installation 3
u
1�cAlteration/Addition/Repair
f._
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED A
BUILDING PERMIT APPLICATION? ElYES LINO
❑RESIDENTIAL
❑BUSINESS CURRENT USE AND OCCUPANCY
❑ASSEMBLY
❑MERCANTILE FUTURE USE AND OCCUPANCY
❑EDUCATIONAL
❑INSTITUTIONAL
❑FACTORY ENGINEER'S NAME PHONE
❑STORAGE
❑GARAGE ADDRESS
❑MIXED USE
CITY STATE ZIP
(Other please specify)
TYPE OF INSTALLATION/WIRING METHOD
SIZE OF SERVICE 6,14 SIZE OF MAIN CONDUCTORS CU
NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO
NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS
NUMBER OF SWITCHES NUMBER OF OUTLETS
NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS
NUMBER OF A/C CIRCUITS
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
; l 1 Z20o7 G -
CONTRACTORS LICENSE N TYPE STATE
SIGNATURE OF APPLICANT DATE / 9 U
RECEIVED
ZONING COMPLIANCE FOR SMALL STRUCTURE
(Sheds and detached decks 200 sq. ft. and smaller) JUL 0 3 2019
Address of Proposed Structure: 164 V(rLyl� Duy , 5. wTND5o2 Zon ��
Name of Owner: _SEFFREY M. FrwwA/ GIS PIN: 4ftoi&4
Phone Number: ` O - 1?S-2-W Application #: —c"9 61 2 5?.E�
1. Name of Applicant: Z7EFFgy M. ppwoeo
Address: 10 H-UTW DUvt; , S. 4T"osR GT 0&074
Phone Number: '660-Tn- ZGW?
2. Structure cannot exceed 200 square feet.
TYPE OF STRUCTURE: _X_ SHED DECK (not to exceed 30"from grade)
DIMENSIONS OF PROPOSED STRUCTURE: V X 1 Z ,
3. A Class D survey must be submitted with the application showing the property lines, all other
buildings and the location of the proposed structure.
4. Is the property served by a septic system? Yes X No If yes, the applicant must
complete and submit a B100a Application to the Health Department for review and approval.
The undersigned hereby permits Town staff to enter onto and inspect this property during
reasonable hours for the purpose of reviewing this application and to determine final compliance
once construction is completed.
I, the undersigned, acknowledge that the above information is true to the best of my knowledge
and that the above requirements are understood.
Applicant Signature: 14 &h ) Date: 7/1 7v i
Owner Signature: Date: 3 Zvf�
*****************************************************************
Reviewed and approved by: Date:
(,,�q!!ny Enforcement Officer
Reviewed and approved by: Date:
Environmental Health Officer
cc: Assessor
Building File SCAN114ED
jOV
O,q
so
10 p•00 ._
J'
29
_ • t
O
\)1. 10 ft. 100.00
^-N rs, /
164 HTutaAi 1)ravc
S. (�v.�N t�5a�. , ur o&o'74
CERTECATION OF ZONING COMPLIANCE
Proposed buRdrtig(s), use(s) and/or struaure(s) as
RECEIVED shown on Cis plan Apptar(s)to be in conformance
with current South Windsor regulations. Variances
and special excepUais may apply.
JUL 0 3 Z019 Dete
South Windsor ement Officer
Suildin Department ��
o IVA 9UiW"''
M.01.n.wA •P���On to
'Jr." 4
f'(w �,�,..,A twudtn4t of •ItNftloM
R'p^ d
rpb �
1SK�
Wim �Ten6mnnt nnPry��aM tOnML
d vtth p'blelop •t14 l a:ar a
;•aP e�dM�tM dwY
gui{dlni state In'+ c •»t tiMtr�
yN YuUd*�• dILlLI
WosM�
of tttM
Oft'
And � yobirct to ttM�l
"ts PI.. _pp '.6W.tiq t+w
eompli.d Whh. T }mod
00066"°MRY APP96VW
oWdMd li
I
1000352 TOWN OF SOUTH WINDSOR, CT
PERMIT NUMBER HVAC PERMIT
DATE: 09/24/10
GIS ID:44100164 FEE: 165.00
MUNIS APPLICATION# 201001277 BUILDING DESCRIPTION:
APPLICANT LOCATION
NAME: AIELLO HOME SERVICES ADDRESS: 164 HILTON DRIVE
ADDRESS: P 0 BOX 548 OWNER: SMEALLIE JAMES ARTHUR
WINDSOR LOCKS,CT 06096 164 HILTON DRIVE
SOUTH WINDSOR,CT 06074
DESCRIPTION OF WORK: GAS BOILER REPLACEMENT
SPECIAL CONDITIONS:
ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT.
CONSTRUCTION TYPE:
OCCUPANCY GROUP: BUILDING OFFICIAL
9/24/2010 11:55 AM THE FEE ABOVE INCLUDES A$0.26 PER THOUSAND CT STATE EDUCATION SURCHARGE