Loading...
HomeMy WebLinkAbout16 DEVONSHIRE DR DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# 4Application l ��� BUILDING DEPARTMENT ED 1540 SULLIVAN AVENUE Bldg. P ,� 644-2511 ext. 230 N it# Date Bu' g Inspector Application must be printed or typed FEE SCHEDULE F Locat* of Job: $0-$1,000=$15.00 Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof gnation Apt. No. APPLICANT — APPLICANT ADDRESS 4A cd SCE APPLICANT PHONE# C/C./ '-/qG, y O W N S OWNER S/9 M F OWNER ADDRESS o , ,r OWNER PHONE ESTIMATED COST$ 3 U00 M •� IS THIS A CONTRACT'�COST? _Yes --No FEE ENCLOSED$ r S a� TYPE OF JOB: OR-CO N V New Installation _Alteration/Addition/Repair Revked am 1 a2nn APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OFF"DING: ❑HEATING B"RESIDENTIAL C O COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. 0 HYDRONIC 0 WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑OIL--GPM OIL TANK LOCATION :❑ INSIDE❑ OUTSIDE CAPACITY ❑GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) --JcarCJ ��f77f ria. S LIC -j r- TONNAGE �5 COOLING CAPACITY(BTUH) 3 6, ODp VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYP STATE SIGNATURE OF APPLICANT DATE a U fi Project Inf• • For: COHEN Design Information Htg Clg Infiltration Outside db(OF) 8 88 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD (OF) 62 13 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(grAb) - 22 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 1399 cfm Actual cooling fan 1399 cfm Heating air flow factor 0.022 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 92 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BED 1 168 7364 3604 166 193 BATH 120 3877 1016 87 54 KITCHEN 196 5452 1401 123 75 FAMILY 266 16623 10669 374 571 DINE 130 5082 2639 114 141 LIVING 240 12989 3885 292 208 BED 3 110 4502 1240 101 66 BED 2 120 6271 1697 141 91 Entire House d 1350 62160 26153 1399 1399 Ventilation air 0 0 Equip. cQ 0.93 RSM 24322 Latent cooling 1 2277 TOTALS 1350 62160 26599 1399 1399 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. ,gjj�, wnghltSOft RiW t-Suns ' 5.0.ee RSR27744 2004 Sep-u 16:02:20 Pro}edi rsr Pepe 1 `s9 mil! �j S O � F Qo $ I � � ro,� r 6 �\ti ;� I i"✓mac vS'irIATZOIV TAh'c i✓ /-RLOM iv1Ar.-S ��NT/TEED W/NDS111RE ABBE !ESTATES LTD. 0/111SE !o SDUTf✓ \ �70 .a 'W/NDSOR CONNECT/CUT TOf'DGRAf'///C /Y/AP 70f /8. :LA7ED 3-Z 3-84 AND W/NOSH/RE ABBE ES7TES LTD, PHAS6 S"32.�iA 590UTi-/ VY/NDSOR CON/YCif7/CUT PL O 7 PLAN 4 01'r-/8. DATED 3-Z3-8�4 pE C N Cl SY 6293 9 CIS1 � ��"rauru:uuu ��prrrrnq�• �3 ?AGE $'73 .�°.� PC ENGINEERING 1750 ELLINGTON ROAD A L 14 °,19' INC. SOUTH WINDSOR CT 06074 203 644-4691 7ff �` :7 y `�.1• ENGW�FR{�•��; J -� DATE: '�iG Qo h h Q, s, N \h. zt Mom ev C- /VT/TLED WIMOSf//RE A,5,5,6- ES T.4TES LTD: 4WASE!o SDUry o • ,a" iWINDSOR CONNECT/CUT 1 TOPOGRAPh//C IM0 70f/B. C� Z=T46S 3-84 AND W/NDSH/RE LTD. PHASE !o SOUTH `iM/NDSOR CON/VEC7/CUT ti 32�/F `PL 07 PLAN 4 OF/8- DATED �3-23.84•. «nnnrmmnJ :i __ r ,, � t _ 't ., ';rt'� s. `�P1 JAL w•(�Gl''% hr b79 C ?AGE ENGINEERING 1750 EWNGTON ROAD INC. SOUTH WINDSOR.CT 06074 20"4-4--4691---� MAIM South WOOM BUR DM 00"Nk"t 1© rhE Elu-r" This I-,cerl c'-P"S Of the Propos'zd bulld';;g erected at 14 IL oc. together with amendments stated 1,1 T,p, tiled with plan and I agree to cor, I Y with CU,c!l-,ti; and state J.jws and sL,ct, d_s —,:ed by the Building Department during i, this applicatlon and final iss f 0 0 nis I is approved subject to the cur,d!tyij t;-,j ord, and crdlnances regulating building shall be with. �cnditianally Approved These filed with Buiidii,g Inspector Cleri, 'fE' '.. / ?3,0 ts- CERTIFICATION OF. ZONING COMIANCE Proposed bullding(s), use(s) and/or structure(s) FIV, as shown on this plan appears) to be In wxzzl conformance with current South Windsor -A.'j regulations. Variances and special exceptions D'ec V may apply. j2'*X4L( ' Date g Enforcement Off;,--- �� ` a ' • Foy���� �( s ^� N E LOT 91 �N �"o NFQgMAT/D/V TAK6N Fi40M MAPS NT/TLED WINOSH/RE ABBE \ �h' o; ES TATE$ L TD, f?�YAS,E!o S DG�T,S' 1 o • .a IWINDSOR CONNECT/CUT 1 �� TOf'DGRAf'H/C MAP 70f/B, .9) 1D-47ED 3-2 3-84 AND W/NOSH/RE S6SY ap . ;ABBE ESTATES LTD, PHASE la 32, SOUTH IVINDSOR CON/VEC7/CUT PZ 07 PLAN 4Ov / D.97E0 13 nrnnrm c i W. Gr' W \ he e19� t R•Y��ti�i�`� �c ,..a>� c 1?c ?AGE ENGINEERING 1750 tiGTo,N;ROAq INC. SOUT 11lIN08OR CT(06 j4 203 6 4=469y i AhPF, OVED TOWN C - r,- 1 'TH 1 I:-r�soFz 1 r' J_ DATE; 5r AOCIO 'NN sf1 Town of South Windsor Building Department �f�OSOR Plumbing Permit: PLMB-21-18 APPLICANT NAME: Marie Varney EMAIL ADDRESS: marie@mitchellfuel.necoxmail.com ADDRESS: PO BOX 1163 1209 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074 LOCATION ADDRESS: 30 DEVONSHIRE DR South Windsor CT 6074 OWNER: GAIGNAT JOHN C 30 DEVONSHIRE DRIVE SOUTH WINDSOR CT 6074 DESCRIPTION OF WORK: INSTALLATION OF A NEW STATE 40 GALLON GAS WATER HEATER. MODEL#GS6. February 16, 2021 BUILDING OFFICIAL DATE SIGNED -ALL WORK TO BE DONE IN ACCORDANCE WITH THE APPLICATION AND PLANS APPROVED BY THE BUILDING DEPARTMENT- "`PERMIT ONLY VALID IF SIGNED BY BUILDING OFFICIAL"'